Wong, Benjamin T; Glassford, Neil J; Bion, Victoria; Chai, Syn Y; Bellomo, Rinaldo
2014-03-01
Blood pressure management (assessed using nursing charts) in the early phase of septic shock may have an effect on renal outcomes. Assessment of mean arterial pressure (MAP) values as recorded on nursing charts may be inaccurate. To determine the difference between hourly blood pressure values as recorded on the nursing charts and hourly average blood pressure values over the corresponding period obtained electronically from the bedside monitor. We studied 20 patients with shock requiring vasopressor support and invasive blood pressure monitoring. Hourly blood pressure measurements were recorded on the nursing charts over a 12-hour period. Blood pressure values recorded every 10 minutes were downloaded from electronic patient monitors over the corresponding period. The hourly average of the 10-minute blood pressure values was compared with the measurements recorded on the nursing charts. We assessed 240 chart readings and 1440 electronic recordings. Average chart MAP was 72.54 mmHg and average electronic monitor MAP was 71.54 mmHg. MAP data from the two sources showed a strong correlation (ρ0.71, P < 0.005). Bland-Altman assessment revealed acceptable agreement, with a mean bias of 1mmHg and 95% limits of agreement of -11.76 mmHg and 13.76 mmHg. Using average data over 6 hours, 95% limits of agreement narrowed to -6.79mmHg and 8.79mmHg. With multiple measurements over time, mean blood pressure as recorded on nursing charts reasonably approximates mean blood pressure recorded on the monitor.
Value of Adult Volunteer Leaders in the New Mexico 4-H Program.
ERIC Educational Resources Information Center
Hutchins, Julie K.; Seevers, Brenda S.; Van Leeuwen, Dawn
2002-01-01
Using data from 187 New Mexico 4-H program volunteers, economic value of volunteer time was determined by calculating the average number of hours spent in 1 year and multiplying the number by the average hourly wage for nonagricultural workers. The data on volunteer activities and their value can be used for program planning, recruitment, and…
40 CFR 63.1574 - What notifications must I submit and when?
Code of Federal Regulations, 2011 CFR
2011-07-01
... analytical methods you will use to determine the equilibrium catalyst Ni concentration, the equilibrium catalyst Ni concentration monthly rolling average, and the hourly or hourly average Ni operating value. (v...
NASA Technical Reports Server (NTRS)
Smith, J. H.
1980-01-01
Average hourly and daily total insolation estimates for 235 United States locations are presented. Values are presented for a selected number of array tilt angles on a monthly basis. All units are in kilowatt hours per square meter.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-23
... standard (NAAQS). This extension is based in part on air quality data for the 4th highest daily 8-hour... attainment date if: (a) For the first one-year extension, the area's 4th highest daily 8-hour average in the... 4th highest daily 8-hour value, averaged over both the original attainment year and the first...
NASA Technical Reports Server (NTRS)
Cliver, E. W.; Ling, A. G.; Richardson, I. G.
2003-01-01
Using a recent classification of the solar wind at 1 AU into its principal components (slow solar wind, high-speed streams, and coronal mass ejections (CMEs) for 1972-2000, we show that the monthly-averaged galactic cosmic ray intensity is anti-correlated with the percentage of time that the Earth is imbedded in CME flows. We suggest that this correlation results primarily from a CME related change in the tail of the distribution function of hourly-averaged values of the solar wind magnetic field (B) between solar minimum and solar maximum. The number of high-B (square proper subset 10 nT) values increases by a factor of approx. 3 from minimum to maximum (from 5% of all hours to 17%), with about two-thirds of this increase due to CMEs. On an hour-to-hour basis, average changes of cosmic ray intensity at Earth become negative for solar wind magnetic field values square proper subset 10 nT.
A new method to estimate average hourly global solar radiation on the horizontal surface
NASA Astrophysics Data System (ADS)
Pandey, Pramod K.; Soupir, Michelle L.
2012-10-01
A new model, Global Solar Radiation on Horizontal Surface (GSRHS), was developed to estimate the average hourly global solar radiation on the horizontal surfaces (Gh). The GSRHS model uses the transmission function (Tf,ij), which was developed to control hourly global solar radiation, for predicting solar radiation. The inputs of the model were: hour of day, day (Julian) of year, optimized parameter values, solar constant (H0), latitude, and longitude of the location of interest. The parameter values used in the model were optimized at a location (Albuquerque, NM), and these values were applied into the model for predicting average hourly global solar radiations at four different locations (Austin, TX; El Paso, TX; Desert Rock, NV; Seattle, WA) of the United States. The model performance was assessed using correlation coefficient (r), Mean Absolute Bias Error (MABE), Root Mean Square Error (RMSE), and coefficient of determinations (R2). The sensitivities of parameter to prediction were estimated. Results show that the model performed very well. The correlation coefficients (r) range from 0.96 to 0.99, while coefficients of determination (R2) range from 0.92 to 0.98. For daily and monthly prediction, error percentages (i.e. MABE and RMSE) were less than 20%. The approach we proposed here can be potentially useful for predicting average hourly global solar radiation on the horizontal surface for different locations, with the use of readily available data (i.e. latitude and longitude of the location) as inputs.
NASA Astrophysics Data System (ADS)
Wintoft, Peter; Wik, Magnus; Matzka, Jürgen; Shprits, Yuri
2017-11-01
We have developed neural network models that predict Kp from upstream solar wind data. We study the importance of various input parameters, starting with the magnetic component Bz, particle density n, and velocity V and then adding total field B and the By component. As we also notice a seasonal and UT variation in average Kp we include functions of day-of-year and UT. Finally, as Kp is a global representation of the maximum range of geomagnetic variation over 3-hour UT intervals we conclude that sudden changes in the solar wind can have a big effect on Kp, even though it is a 3-hour value. Therefore, 3-hour solar wind averages will not always appropriately represent the solar wind condition, and we introduce 3-hour maxima and minima values to some degree address this problem. We find that introducing total field B and 3-hour maxima and minima, derived from 1-minute solar wind data, have a great influence on the performance. Due to the low number of samples for high Kp values there can be considerable variation in predicted Kp for different networks with similar validation errors. We address this issue by using an ensemble of networks from which we use the median predicted Kp. The models (ensemble of networks) provide prediction lead times in the range 20-90 min given by the time it takes a solar wind structure to travel from L1 to Earth. Two models are implemented that can be run with real time data: (1) IRF-Kp-2017-h3 uses the 3-hour averages of the solar wind data and (2) IRF-Kp-2017 uses in addition to the averages, also the minima and maxima values. The IRF-Kp-2017 model has RMS error of 0.55 and linear correlation of 0.92 based on an independent test set with final Kp covering 2 years using ACE Level 2 data. The IRF-Kp-2017-h3 model has RMSE = 0.63 and correlation = 0.89. We also explore the errors when tested on another two-year period with real-time ACE data which gives RMSE = 0.59 for IRF-Kp-2017 and RMSE = 0.73 for IRF-Kp-2017-h3. The errors as function of Kp and for different years are also studied.
40 CFR 63.4364 - What are the requirements for CPMS installation, operation, and maintenance?
Code of Federal Regulations, 2010 CFR
2010-07-01
... valid hour of data. (2) You must have valid data from at least 90 percent of the hours during which the... three of four equally spaced data values from that hour from a continuous monitoring system (CMS) that... that period using only average values that are based on valid data (i.e., not from out-of-control...
40 CFR 63.4364 - What are the requirements for CPMS installation, operation, and maintenance?
Code of Federal Regulations, 2011 CFR
2011-07-01
... valid hour of data. (2) You must have valid data from at least 90 percent of the hours during which the... three of four equally spaced data values from that hour from a continuous monitoring system (CMS) that... that period using only average values that are based on valid data (i.e., not from out-of-control...
Development Study of Pedestrian Bridge at Gramedia Bookstore Jalan Raden Intan Bandar Lampung
NASA Astrophysics Data System (ADS)
Bernaditha, C. M.
2018-03-01
Bandar Lampung with high enough population densities has provides transportation facilities for pedestrian such as pedestrian bridge. This pedestrian bridges spread at Bandar Lampung’s traffic congested area, shopping centre nor education centre. Jl. Raden Intan as one of primary collector road with four lanes one direction at Bandar Lampung has high LHR (average daily traffic) movemenet pattern especially at morning, day and afternoon rush hour that make it difficult for pedestrian who want to cross the road. Therefore pedes trian bridge at this section Jl. Raden Intan highly needed especially at in front of Gramedia Bookstore with large amount of crossing pedestrian volume. From this research and analysis, found that number of LHR (average daily traffic) at Jl. Raden Intan shows large number traffic volume that is 4509 passenger car unit/hour at morning rush hour (07.00-08.30), with value of V/C Ratio or Degree of Saturation reach 0,92 (E category), while the amount of pedestrian who cross ahead from Gramedia Bookstore to Bank Muammalat is 29 people per 15 minutes. Other than that based on the calculation results of pedestrian volume and traffic volume at rush hour as follow: average pedestrian volume at rush hour is 146 people/hour between the range 100-1250 people/hour and traffic volume 7521 vehicles/hour over than 7000 vehicles/hour, and also the value PV2=1,682x1010 which is means the value of PV2 worth over 2x108, moreover the speed plan Jl. Raden Intan between 60-80 km/hour above 70 km/hour. Based on the calculation and analysis above, it can be concluded transportation facilities recommended for Jl. Raden Intan is pedestrian bridge.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-09
... Philadelphia Area's 4th highest daily 8-hour monitored ozone value during the 2009 ozone season at each monitor...-year extensions of the attainment date if: (a) For the first 1-year extension, the area's 4th highest... second 1-year extension, the area's 4th highest daily 8-hour value, averaged over both the original...
Code of Federal Regulations, 2011 CFR
2011-07-01
... to 1-year extensions of the attainment date if: (a) For the first 1-year extension, the area's 4th... extension, the area's 4th highest daily 8-hour value, averaged over both the original attainment year and... section, the area's 4th highest daily 8-hour average shall be from the monitor with the highest 4th...
Code of Federal Regulations, 2013 CFR
2013-07-01
... to 1-year extensions of the attainment date if: (a) For the first 1-year extension, the area's 4th... extension, the area's 4th highest daily 8-hour value, averaged over both the original attainment year and... section, the area's 4th highest daily 8-hour average shall be from the monitor with the highest 4th...
Code of Federal Regulations, 2012 CFR
2012-07-01
... to 1-year extensions of the attainment date if: (a) For the first 1-year extension, the area's 4th... extension, the area's 4th highest daily 8-hour value, averaged over both the original attainment year and... section, the area's 4th highest daily 8-hour average shall be from the monitor with the highest 4th...
Vladymyrov, O A; Tofan, N I
2003-01-01
Investigations on using of index possibilities of L-arginin/NO system in evaluation of sanatorium-resort treatment effectiveness of pregnant with cardiovascular disorders were conducted. It was analyzed the dynamics of twenty four hour cycle rhythm of L-arginin and total nitrites and nitrates constance in saliva of 58 pregnant, 20 of which were suffering from metabolic cardiomyopathy, 23-from neurocirculatory dystonia and 15 were healthy pregnant. As the result of examination there were found out considerable changes of parameter values of biological rhythms: duration of rhythm, average twenty four hour cycle range of activity, amount of difference between max index per twenty hour cycle and average index per twenty hour cycle, period of max and min activity. Analysis of tendencies of twenty four hour cycles rhythms concerning dynamics of sanatorium-resort treatment will give possibility to define characteristic features of recovering values of this parameter.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-09
... 4th highest daily 8-hour monitored ozone value during the 2009 ozone season is 0.084 parts per million... extensions of the attainment date if: (a) For the first 1-year extension, the area's 4th highest daily 8...'s 4th highest daily 8-hour value, averaged over both the original attainment year and the first...
Analysis of the solar radiation data for Beer Sheva, Israel, and its environs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kudish, A.I.; Ianetz, A.
The solar radiation climate of Beer Sheva, Israel, is reported upon in detail. The database utilized in this analysis consisted of global radiation on a horizontal surface, normal incidence beam radiation, and global radiation on a south-facing surface tilted at 40{degree}. Monthly-average hourly and daily values are reported for each of these three types of measured radiations, together with the calculated monthly-average daily values for the components of the global radiation, viz. the horizontal beam and diffuse radiations. The monthly-average hourly and daily clearness index values have also been calculated and analyzed. Monthly-average daily frequency distributions of the clearness indexmore » values are reported for each month. The solar radiation climate of Beer Sheva has also been compared to those reported for a number of countries in this region. The annual-average daily global radiation incident on a horizontal surface is 18.91 MG/m{sup 2} and that for normal incidence beam radiation is 21.17 MG/m{sup 2}. The annual-average daily fraction of the horizontal global radiation that is beam is 0.72. The annual-average daily value for the clearness index is 0.587 and the average frequency of clear days annually is 58.6%. The authors conclude, based upon the above analysis, that Beer Sheva and its environs are characterized by relatively high, average-daily irradiation rates, both global and beam, and a relatively high frequency of clear days.« less
Kaya, A; Okur, M; Sal, E; Peker, E; Köstü, M; Tuncer, O; Kırımi, E
2014-12-01
The monitoring of oxygenation is essential for providing patient safety and optimal results. We aimed to determine brain oxygen saturation values in healthy, asphyctic and premature newborns and to compare cerebral oximeter and pulse oximeter values in the first 72 hours of life in neonatal intensive care units. This study was conducted at the neonatal intensive care unit (NICU) of Van Yüzüncü Yil University Research and Administration Hospital. Seventy-five neonatal infants were included in the study (28 asphyxia, 24 premature and 23 mature healthy infants for control group). All infants were studied within the first 72 hours of life. We used a Somanetics 5100C cerebral oximeter (INVOS cerebral/somatic oximeter, Troy, MI, USA). The oxygen saturation information was collected by a Nellcor N-560 pulse oximeter (Nellcor-Puriton Bennet Inc, Pleasanton, CA, USA). In the asphyxia group, the cerebral oximeter average was 76.85 ± 14.1, the pulse oximeter average was 91.86 ± 5.9 and the heart rate average was 139.91 ± 22.3. Among the premature group, the cerebral oximeter average was 79.08 ± 9.04, the pulse oximeter average was 92.01 ± 5.3 and the heart rate average was 135.35 ± 17.03. In the control group, the cerebral oximeter average was 77.56 ± 7.6, the pulse oximeter average was 92.82 ± 3.8 and the heart rate average was 127.04 ± 19.7. Cerebral oximeter is a promising modality in bedside monitoring in neonatal intensive care units. It is complementary to pulse oximeter. It may be used routinely in neonatal intensive care units.
Kaya, A; Okur, M; Sal, E; Peker, E; Köstü, M; Tuncer, O; Kirimi, E
2014-01-01
ABSTRACT Aim: The monitoring of oxygenation is essential for providing patient safety and optimal results. We aimed to determine brain oxygen saturation values in healthy, asphyctic and premature newborns and to compare cerebral oximeter and pulse oximeter values in the first 72 hours of life in neonatal intensive care units. Methods: This study was conducted at the neonatal intensive care unit (NICU) of Van Yüzüncü Yil University Research and Administration Hospital. Seventy-five neonatal infants were included in the study (28 asphyxia, 24 premature and 23 mature healthy infants for control group). All infants were studied within the first 72 hours of life. We used a Somanetics 5100C cerebral oximeter (INVOS cerebral/somatic oximeter, Troy, MI, USA). The oxygen saturation information was collected by a Nellcor N-560 pulse oximeter (Nellcor-Puriton Bennet Inc, Pleasanton, CA, USA). Results: In the asphyxia group, the cerebral oximeter average was 76.85 ± 14.1, the pulse oximeter average was 91.86 ± 5.9 and the heart rate average was 139.91 ± 22.3. Among the premature group, the cerebral oximeter average was 79.08 ± 9.04, the pulse oximeter average was 92.01 ± 5.3 and the heart rate average was 135.35 ± 17.03. In the control group, the cerebral oximeter average was 77.56 ± 7.6, the pulse oximeter average was 92.82 ± 3.8 and the heart rate average was 127.04 ± 19.7. Conclusion: Cerebral oximeter is a promising modality in bedside monitoring in neonatal intensive care units. It is complementary to pulse oximeter. It may be used routinely in neonatal intensive care units. PMID:25867556
Ang, Dan B; Angelopoulos, Christos; Katz, Jerald O
2006-11-01
The goals of this in vitro study were to determine the effect of signal fading of DenOptix photo-stimulable storage phosphor imaging plates scanned with a delay and to determine the effect on the diagnostic quality of the image. In addition, we sought to correlate signal fading with image spatial resolution and average pixel intensity values. Forty-eight images were obtained of a test specimen apparatus and scanned at 6 delayed time intervals: immediately scanned, 1 hour, 8 hours, 24 hours, 72 hours, and 168 hours. Six general dentists using Vixwin2000 software performed a measuring task to determine the location of an endodontic file tip and root apex. One-way ANOVA with repeated measures was used to determine the effect of signal fading (delayed scan time) on diagnostic image quality and average pixel intensity value. There was no statistically significant difference in diagnostic image quality resulting from signal fading. No difference was observed in spatial resolution of the images. There was a statistically significant difference in the pixel intensity analysis of an 8-step aluminum wedge between immediate scanning and 24-hour delayed scan time. There was an effect of delayed scanning on the average pixel intensity value. However, there was no effect on image quality and raters' ability to perform a clinical identification task. Proprietary software of the DenOptix digital imaging system demonstrates an excellent ability to process a delayed scan time signal and create an image of diagnostic quality.
Estimating systemic exposure to ethinyl estradiol from an oral contraceptive.
Westhoff, Carolyn L; Pike, Malcolm C; Tang, Rosalind; DiNapoli, Marianne N; Sull, Monica; Cremers, Serge
2015-05-01
This study was conducted to compare single-dose pharmacokinetics of ethinyl estradiol in an oral contraceptive with steady-state values and to assess whether any simpler measures could provide an adequate proxy of the "gold standard" 24-hour steady-state area under the curve (AUC) value. Identification of a simple, less expensive measure of systemic ethinyl estradiol exposure would be useful for larger studies that are designed to assess the relationship between an individual's ethinyl estradiol exposure and side-effects. We collected 13 samples over 24 hours for pharmacokinetic analysis on days 1 and 21 of the first cycle of a monophasic oral contraceptive that contained 30 μg ethinyl estradiol and 150 μg levonorgestrel in 17 nonobese healthy white women. We also conducted an abbreviated single-dose 9-sample pharmacokinetic analysis after a month washout. Ethinyl estradiol was measured by liquid chromatography-tandem mass spectrometry. We compared results of a full 13-sample steady-state pharmacokinetic analysis with results that had been calculated with the use of fewer samples (9 or 5) and after the single doses. We calculated Pearson correlation coefficients to evaluate the relationships between these estimates of systemic ethinyl estradiol exposure. The AUC, maximum, and 24-hour values were similar after the 2 single oral contraceptive doses (AUC; r=0.92). The steady-state 13-sample 24-hour AUC value was correlated highly with the average 9-sample AUC value after the 2 single doses (r=0.81; P=.0002). This correlation remained the same if the number of single-dose samples was reduced to 4, taken at time 1, 2.5, 4, and 24 hours. The 24-hour value at steady-state was correlated highly with the 24-hour steady-state AUC value (r=0.92; P<.0001). The average of the 24-hour values after the 2 single doses was also correlated quite highly with the steady-state AUC value (r=0.72; P=.0026). Limited blood sampling, including results from 2 single doses, gave highly correlated estimates of an oral contraceptive user's steady-state ethinyl estradiol exposure. Copyright © 2015 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-07-01
... series of daily values represents the 98th percentile for that year. Creditable samples include daily... measured (or averaged from hourly measurements in AQS) from midnight to midnight (local standard time) from... design value (DV) or a 24-hour PM2.5 NAAQS DV to determine if those metrics, which are judged to be based...
24 CFR 51.106 - Implementation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... day-night average sound level data are not available may be evaluated from NEF or CNEL analyses using.... The day-night average sound level may be estimated from the design hour L10 or Leq values by the.... The Department of Defense uses day-night average sound level based on C-weighted sound level...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-16
.... FMCSA used a look-up table for scaling the individual hours of work in the previous week. Look-up tables...). Column C (cells C93-137) presents the values scaled to our average work (52 hours per week of work) and... Evaluation to link the hours worked in the previous week to fatigue the following week. On January 28, 2011...
Cripps, T; Bennett, E D; Camm, A J; Ward, D E
1988-01-01
The value of the high gain, signal averaged electrocardiogram combined with 24 hour electrocardiographic monitoring in the prediction of arrhythmic events was assessed in 159 patients in the first week after myocardial infarction. Eleven patients (7%) suffered arrhythmic events during a mean (SD) of 12 (6) months of follow up (range 2-22, median 13 months). The combination of high gain, signal averaged electrocardiography and 24 hour electrocardiographic monitoring was more accurate than either technique alone or than clinical information collected during admission in predicting these events. The combination identified a high risk group of 13 (8%) patients, with an arrhythmic event rate of 62% and a low risk group with an event rate of 2%. The combination of high gain, signal averaged electrocardiography and 24 hour electrocardiographic monitoring in the first week after myocardial infarction provides a rapid, cheap, and non-invasive bedside method for the prediction of arrhythmias. PMID:3179133
Shepard, Donald S; Halasa, Yara A; Fonseca, Dina M; Farajollahi, Ary; Healy, Sean P; Gaugler, Randy; Bartlett-Healy, Kristen; Strickman, Daniel A; Clark, Gary G
2014-01-01
Aedes albopictus is the most invasive mosquito in the world, an important disease vector, and a biting nuisance that limits outdoor activities. Area-wide integrated pest management (AW-IPM) is the recommended control strategy. We conducted an economic evaluation of the AW-IPM project in Mercer and Monmouth Counties, New Jersey with a controlled design (AW-IPM vs. control) from 2009 through 2011. The study analyzed financial documents and staff time for AW-IPM and surveyed an average of 415 randomly chosen households in AW-IPM and control areas each fall from 2008 through 2011. Hours lost from yard and porch activities were calculated as differences between actual and potential hours of these activities in an average summer week if there had been no mosquito concerns. Net estimated benefits of AW-IPM were based on cross-over and difference-in-difference analyses. Reductions in hours lost were valued based on respondents' willingness to pay for a hypothetical extra hour free of mosquitoes spent on yard or porch activities and literature on valuation of a quality adjusted life year (QALY). The incremental cost of AW-IPM per adult was $41.18 per year. Number of hours lost due to mosquitoes in AW-IPM areas between the base year (2008) and the intervention years (2009-2011) declined by 3.30 hours per summer week in AW-IPM areas compared to control areas. Survey respondents valued this improvement at $27.37 per adult per summer week. Over the 13-week summer, an average adult resident gained 42.96 hours of yard and porch time, worth $355.82. The net benefit over the summer was $314.63. With an average of 0.0027 QALYs gained per adult per year, AW-IPM was cost effective at $15,300 per QALY gained. The benefit-cost ratio from hours gained was 8.64, indicating that each $1 spent on AW-IPM gave adults additional porch and yard time worth over $8.
Yin, Wesley; Horblyuk, Ruslan; Perkins, Julia Jane; Sison, Steve; Smith, Greg; Snider, Julia Thornton; Wu, Yanyu; Philipson, Tomas J
2017-02-01
Determine workplace productivity losses attributable to breast cancer progression. Longitudinal analysis linking 2005 to 2012 medical and pharmacy claims and workplace absence data in the US patients were commercially insured women aged 18 to 64 diagnosed with breast cancer. Productivity was measured as employment status and total quarterly workplace hours missed, and valued using average US wages. Six thousand four hundred and nine women were included. Breast cancer progression was associated with a lower probability of employment (hazard ratio [HR] = 0.65, P < 0.01) and increased workplace hours missed. The annual value of missed work was $24,166 for non-metastatic and $30,666 for metastatic patients. Thus, progression to metastatic disease is associated with an additional $6500 in lost work time (P < 0.05), or 14% of average US wages. Breast cancer progression leads to diminished likelihood of employment, increased workplace hours missed, and increased cost burden.
Does the Market Value Racial and Ethnic Concordance in Physician–Patient Relationships?
Brown, Timothy T; Scheffler, Richard M; Tom, Sarah E; Schulman, Kevin A
2007-01-01
Objective To determine if the market-determined earnings per hour of physicians is sensitive to the degree of area-level racial/ethnic concordance (ALREC) in the local physician labor market. Data Sources 1998–1999 and 2000–2001 Community Tracking Study Physician Surveys and Household Surveys, 2000 U.S. Census, and the Area Resource File. Study Design Population-averaged regression models with area-level fixed effects were used to estimate the determinants of log earnings per hour for physicians in a two-period panel (N = 12,886). ALREC for a given racial/ethnic group is measured as the percentage of physicians who are of a given race/ethnicity less the percentage of the population who are of the corresponding race/ethnicity. Relevant control variables were included. Principal Findings Average earnings per hour for Hispanic and Asian physicians varies with the degree of ALREC that corresponds to a physician's race/ethnicity. Both Hispanic and Asian physicians earn more per hour in areas where corresponding ALREC is negative, other things equal. ALREC varies from negative to positive for all groups. ALREC for Hispanics is negative, on average, due to the small percentage of the physician workforce that is Hispanic. This results in an average 5.6 percent earnings-per-hour premium for Hispanic physicians. However, ALREC for Asians is positive, on average, due to the large percentage of the physician workforce that is Asian. This results in an average 4.0 percent earnings-per-hour discount for Asian physicians. No similar statistically significant results were found for black physicians. Conclusions The market-determined earnings per hour of Hispanic and Asian physicians are sensitive to the degree of ALREC in the local labor market. Larger sample sizes may be needed to find statistically significant results for black physicians. PMID:17362214
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-11
...). This extension is based on the air quality data for the 4th highest daily 8-hour monitored value during... first one-year extension, the area's 4th highest daily 8-hour average in the attainment year is 0.084 parts per million (ppm) or less. (b) For the second one-year extension, the area's 4th highest daily 8...
Olivares-Urueta, Mayra; Williamson, Jon W
2013-01-01
Pre-admission factors tend to serve as indicators of student success in health professions educational programs, but less is known about the effects that academic assistance programs have on student success. This study sought to determine whether specific pre-admission factors could help to identify students who may require academic support during their health professions education. This retrospective analysis aimed to identify differences in pre-admission variables between those students requiring tutoring and a matched sample of students who did not require tutoring. One-way ANOVA was used to assess differences for dependent variables-age, cumulative GPA (cGPA), science GPA (sGPA), verbal graduate record examination (GRE) score, quantitative GRE score, analytical GRE score and combined GRE score, community college hours, average credit hours per semester, and highest semester credit hour load-across three groups of students who received no tutoring (NT 0 hrs), some tutoring (ST <8 hrs), and more tutoring (MT >8 hrs). Total GRE and average semester hours differentiated NT from ST from MT (p<0.05). A linear regression model with these pre-admission factors found only four of the independent variables to be significant (r2=0.41; p<0.05) in predicting hours of tutoring: quantitative GRE, sGPA, cGPA and average semester hours taken. The combination of lower GRE scores and lighter average semester course load were most predictive of the need for academic assistance as defined by hours of tutoring. While the value of the GRE in admissions processes is generally accepted, the average semester hour load in college can also provide important information regarding academic preparation and the need for tutoring services.
Costs of informal nursing care for patients with neurologic disorders: A systematic review.
Diederich, Freya; König, Hans-Helmut; Mietzner, Claudia; Brettschneider, Christian
2018-01-02
To systematically review the economic burden of informal nursing care (INC), often called informal care, caused by multiple sclerosis (MS), Parkinson disease (PD), and epilepsy, with special attention to disease severity. We systematically searched MEDLINE, PsycINFO, and NHS Economic Evaluation Database for articles on the cost of illness of the diseases specified. Title, abstract, and full-text review were conducted in duplicate by 2 researchers. The distribution of hours and costs of INC were extracted and used to compare the relevance of INC across included diseases and disease severity. Seventy-one studies were included (44 on MS, 17 on PD, and 10 on epilepsy). Studies on epilepsy reported an average of 2.3-54.5 monthly hours of INC per patient. For PD, average values of 42.9-145.9 hours and for MS average values of 9.2-249 hours per patient per month were found. In line with utilized hours, costs of INC were lowest for epilepsy (interquartile range [IQR] 229-1,466 purchasing power parity US dollars [PPP-USD]) and similar for MS (IQR 4,454-11,222 PPP-USD) and PD (IQR 1,440-7,117 PPP-USD). In addition, costs of INC increased with disease severity and accounted for 38% of total health care costs in severe MS stages on average. The course of diseases and disease severity matter for the amount of INC used by patients. For each of the neurologic disorders, an increase in the costs of INC, due to increasing disease severity, considerably contributes to the rise in total health care costs. Copyright © 2017 American Academy of Neurology.
40 CFR 600.311-12 - Determination of values for fuel economy labels.
Code of Federal Regulations, 2014 CFR
2014-07-01
... value from paragraph (a) of this section, in miles per kW-hour. (4) For hydrogen fuel cell vehicles... for hydrogen fuel cell vehicles. MPG = The combined fuel economy value from paragraph (a) of this... hydrogen fuel cell vehicles. Average Annual Miles = The estimated annual mileage figure provided by EPA, in...
40 CFR 600.311-12 - Determination of values for fuel economy labels.
Code of Federal Regulations, 2013 CFR
2013-07-01
... value from paragraph (a) of this section, in miles per kW-hour. (4) For hydrogen fuel cell vehicles... for hydrogen fuel cell vehicles. MPG = The combined fuel economy value from paragraph (a) of this... hydrogen fuel cell vehicles. Average Annual Miles = The estimated annual mileage figure provided by EPA, in...
Data challenges in estimating the capacity value of solar photovoltaics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gami, Dhruv; Sioshansi, Ramteen; Denholm, Paul
We examine the robustness of solar capacity-value estimates to three important data issues. The first is the sensitivity to using hourly averaged as opposed to subhourly solar-insolation data. The second is the sensitivity to errors in recording and interpreting load data. The third is the sensitivity to using modeled as opposed to measured solar-insolation data. We demonstrate that capacity-value estimates of solar are sensitive to all three of these factors, with potentially large errors in the capacity-value estimate in a particular year. If multiple years of data are available, the biases introduced by using hourly averaged solar-insolation can be smoothedmore » out. Multiple years of data will not necessarily address the other data-related issues that we examine. Our analysis calls into question the accuracy of a number of solar capacity-value estimates relying exclusively on modeled solar-insolation data that are reported in the literature (including our own previous works). Lastly, our analysis also suggests that multiple years’ historical data should be used for remunerating solar generators for their capacity value in organized wholesale electricity markets.« less
Data Challenges in Estimating the Capacity Value of Solar Photovoltaics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gami, Dhruv; Sioshansi, Ramteen; Denholm, Paul
We examine the robustness of solar capacity-value estimates to three important data issues. The first is the sensitivity to using hourly averaged as opposed to subhourly solar-insolation data. The second is the sensitivity to errors in recording and interpreting load data. The third is the sensitivity to using modeled as opposed to measured solar-insolation data. We demonstrate that capacity-value estimates of solar are sensitive to all three of these factors, with potentially large errors in the capacity-value estimate in a particular year. If multiple years of data are available, the biases introduced by using hourly averaged solar-insolation can be smoothedmore » out. Multiple years of data will not necessarily address the other data-related issues that we examine. Our analysis calls into question the accuracy of a number of solar capacity-value estimates relying exclusively on modeled solar-insolation data that are reported in the literature (including our own previous works). Our analysis also suggests that multiple years' historical data should be used for remunerating solar generators for their capacity value in organized wholesale electricity markets.« less
Data challenges in estimating the capacity value of solar photovoltaics
Gami, Dhruv; Sioshansi, Ramteen; Denholm, Paul
2017-04-30
We examine the robustness of solar capacity-value estimates to three important data issues. The first is the sensitivity to using hourly averaged as opposed to subhourly solar-insolation data. The second is the sensitivity to errors in recording and interpreting load data. The third is the sensitivity to using modeled as opposed to measured solar-insolation data. We demonstrate that capacity-value estimates of solar are sensitive to all three of these factors, with potentially large errors in the capacity-value estimate in a particular year. If multiple years of data are available, the biases introduced by using hourly averaged solar-insolation can be smoothedmore » out. Multiple years of data will not necessarily address the other data-related issues that we examine. Our analysis calls into question the accuracy of a number of solar capacity-value estimates relying exclusively on modeled solar-insolation data that are reported in the literature (including our own previous works). Lastly, our analysis also suggests that multiple years’ historical data should be used for remunerating solar generators for their capacity value in organized wholesale electricity markets.« less
Wood, James L.; Andraski, Brian J.
1995-01-01
Selected meteorological data were collected at a study site adjacent to a low-level radioactive-waste burial facility near Beatty, Nevada, for calendar years 1990 and 1991. Data were collected in support of ongoing studies to estimate the potential for downward movement of radionuclides into the unsaturated sediments beneath waste-burial trenches at the facility. The data include air temperature, relative humidity, vapor pressure, incident solar radiation, windspeed, wind direction, barometric pressure, and precipitation. The data are summarized in tables and graphs.Instrumentation used at the site is discussed. The discussion includes the type, reported accuracy, and mounting height of each sensor.In 1990, the average hourly air temperatures ranged from -16.2 degrees Celsius, in December, to 44.2 degrees Celsius, in July. Hourly averaged relative humidity ranged from 6 percent to more than 90 percent. Hourly vapor pressures ranged from 0.08 to 1.84 kilopascals. Daily maximum incident solar radiation values ranged from 192 to 1,028 watts per square meter. Daily mean windspeed ranged from less than 1 to 8.7 meters per second. Wind direction was primarily from the northwest in fall, winter, and spring and varied from southeast, southwest, or northwest during the summer. Hourly barometric pressures ranged from 99.47 to 103.12 kilopascals. Total precipitation for 1990 was 32.4 millimeters; almost 45 percent was in September.In 1991, the average hourly air temperatures ranged from -9.2 degrees Celsius, in January, to 43.7 degrees Celsius, in July. Hourly averaged relative humidity ranged from 3 percent to more than 95 percent. Hourly vapor pressures ranged from 0.07 to 2.22 kilopascals. Daily maximum incident solar radiation values ranged from 143 to 1,041 watts per square meter. Daily mean windspeed ranged from 1.2 to 8.4 meters per second. Wind direction was primarily from the northwest in fall, winter, and spring and varied from southeast, southwest, or northwest during the summer. Hourly barometric pressures ranged from 99.52 to 103.40 kilopascals. Total precipitation for 1991 was 103.6 millimeters; almost 60 percent was in March.
Shepard, Donald S.; Halasa, Yara A.; Fonseca, Dina M.; Farajollahi, Ary; Healy, Sean P.; Gaugler, Randy; Bartlett-Healy, Kristen; Strickman, Daniel A.; Clark, Gary G.
2014-01-01
Aedes albopictus is the most invasive mosquito in the world, an important disease vector, and a biting nuisance that limits outdoor activities. Area-wide integrated pest management (AW-IPM) is the recommended control strategy. We conducted an economic evaluation of the AW-IPM project in Mercer and Monmouth Counties, New Jersey with a controlled design (AW-IPM vs. control) from 2009 through 2011. The study analyzed financial documents and staff time for AW-IPM and surveyed an average of 415 randomly chosen households in AW-IPM and control areas each fall from 2008 through 2011. Hours lost from yard and porch activities were calculated as differences between actual and potential hours of these activities in an average summer week if there had been no mosquito concerns. Net estimated benefits of AW-IPM were based on cross-over and difference-in-difference analyses. Reductions in hours lost were valued based on respondents' willingness to pay for a hypothetical extra hour free of mosquitoes spent on yard or porch activities and literature on valuation of a quality adjusted life year (QALY). The incremental cost of AW-IPM per adult was $41.18 per year. Number of hours lost due to mosquitoes in AW-IPM areas between the base year (2008) and the intervention years (2009-2011) declined by 3.30 hours per summer week in AW-IPM areas compared to control areas. Survey respondents valued this improvement at $27.37 per adult per summer week. Over the 13-week summer, an average adult resident gained 42.96 hours of yard and porch time, worth $355.82. The net benefit over the summer was $314.63. With an average of 0.0027 QALYs gained per adult per year, AW-IPM was cost effective at $15,300 per QALY gained. The benefit-cost ratio from hours gained was 8.64, indicating that each $1 spent on AW-IPM gave adults additional porch and yard time worth over $8. PMID:25338065
Estimation of global radiation for Sri Lanka
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samuel, T.D.M.A.
1991-01-01
There are several formulae that relate global radiation to other climatological parameters such as sunshine hours, relative humidity, maximum temperature, and average temperature. In this paper a generally accepted modified form of the formula first introduced by Angstrom is used. It relates global radiation to hours of sunshine that have been measured for several years in many of the meteorological stations in Sri Lanka. The annual average of the ratio of the hours of sunshine to the length of the day, i.e., annual average of (S/Z), is found to vary considerably and to lie in the range 0.42-0.66. Fre're etmore » al., have found, using data from many parts of the world, a general graphical representation for the variation of a and b with annual average (S/Z) lying in the range 0.28 to 0.75. This variation of a and b can be expressed as quadratic functions are modified and used to determine a and b values for stations in Sri Lanka.« less
Noise level in a neonatal intensive care unit in Santa Marta - Colombia.
Garrido Galindo, Angélica Patricia; Camargo Caicedo, Yiniva; Velez-Pereira, Andres M
2017-09-30
The environment of neonatal intensive care units is influenced by numerous sources of noise emission, which contribute to raise the noise levels, and may cause hearing impairment and other physiological and psychological changes on the newborn, as well as problems with care staff. To evaluate the level and sources of noise in the neonatal intensive care unit. Sampled for 20 consecutive days every 60 seconds in A-weighting curves and fast mode with a Type I sound level meter. Recorded the average, maximum and minimum, and the 10th, 50th and 90th percentiles. The values are integrated into hours and work shift, and studied by analysis of variance. The sources were characterized in thirds of octaves. The average level was 64.00 ±3.62 dB(A), with maximum of 76.04 ±5.73 dB(A), minimum of 54.84 ±2.61dB(A), and background noise of 57.95 ±2.83 dB(A). We found four sources with levels between 16.8-63.3 dB(A). Statistical analysis showed significant differences between the hours and work shift, with higher values in the early hours of the day. The values presented exceed the standards suggested by several organizations. The sources identified and measured recorded high values in low frequencies.
Decreased mortality associated with prompt Gram staining of blood cultures.
Barenfanger, Joan; Graham, Donald R; Kolluri, Lavanya; Sangwan, Gaurav; Lawhorn, Jerry; Drake, Cheryl A; Verhulst, Steven J; Peterson, Ryan; Moja, Lauren B; Ertmoed, Matthew M; Moja, Ashley B; Shevlin, Douglas W; Vautrain, Robert; Callahan, Charles D
2008-12-01
Gram stains of positive blood cultures are the most important factor influencing appropriate therapy. The sooner appropriate therapy is initiated, the better. Therefore, it is reasonable to expect that the sooner Gram stains are performed, the better. To determine the value of timely Gram stains and whether improvement in Gram stain turnaround time (TAT) is feasible, we compared data for matched pairs of patients with cultures processed promptly (<1 hour TAT) with data for patients with cultures not processed promptly (> or =1 hour TAT) and then monitored TAT by control charting.In 99 matched pairs, average difference in time to detection of positive blood cultures within a pair of patients was less than 0.1 hour. For the less than 1 hour TAT group, the average TAT and crude mortality were 0.1 hour and 10.1%, respectively; for the 1 hour or longer TAT group, they were 3.3 hours and 19.2%, respectively (P < .0001 and P = .0389, respectively). After multifaceted efforts, we achieved significant improvement in the TAT for Gram stains.
Katz, Erin M; Scott, Ruth M; Thomson, Christopher B; Mesa, Eileen; Evans, Richard; Conzemius, Michael G
2017-11-01
Objective To determine if environmental variables affect the average daily activity counts (AC) of dogs with osteoarthritis (OA) and/or owners' perception of their dog's clinical signs or quality of life. Methods The AC and Canine Brief Pain Inventory (CBPI) owner questionnaires of 62 dogs with OA were compared with daily environmental variables including the following: average temperature (°C), high temperature (°C), low temperature (°C), relative humidity (%), total precipitation (mm), average barometric pressure (hPa) and total daylight hours. Results Daily AC significantly correlated with average temperature and total daylight hours, but average temperature and total daylight hours accounted for less than 1% of variation in AC. No other significant relationships were found between daily AC and daily high temperature, low temperature, relative humidity, total precipitation or average barometric pressure. No statistical relationship was found between daily AC and the CBPI, nor between environmental variables and the CBPI. Canine Brief Pain Inventory scores for pain severity and pain interference decreased significantly over the test period. Clinical Significance The relationship between daily AC and average temperature and total daylight hours was significant, but unlikely to be clinically significant. Thus, environmental variables do not appear to have a clinically relevant bias on AC or owner CBPI questionnaires. The decrease over time in CBPI pain severity and pain interference values suggests owners completing the CBPI in this study were influenced by a caregiver placebo effect. Schattauer GmbH Stuttgart.
40 CFR 98.295 - Procedures for estimating missing data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... value shall be the best available estimate(s) of the parameter(s), based on all available process data or data used for accounting purposes. (c) For each missing value collected during the performance test (hourly CO2 concentration, stack gas volumetric flow rate, or average process vent flow from mine...
NASA Astrophysics Data System (ADS)
Villarini, Gabriele; Khouakhi, Abdou; Cunningham, Evan
2017-12-01
Daily temperature values are generally computed as the average of the daily minimum and maximum observations, which can lead to biases in the estimation of daily averaged values. This study examines the impacts of these biases on the calculation of climatology and trends in temperature extremes at 409 sites in North America with at least 25 years of complete hourly records. Our results show that the calculation of daily temperature based on the average of minimum and maximum daily readings leads to an overestimation of the daily values of 10+ % when focusing on extremes and values above (below) high (low) thresholds. Moreover, the effects of the data processing method on trend estimation are generally small, even though the use of the daily minimum and maximum readings reduces the power of trend detection ( 5-10% fewer trends detected in comparison with the reference data).
[Travel time and distances to Norwegian out-of-hours casualty clinics].
Raknes, Guttorm; Morken, Tone; Hunskår, Steinar
2014-11-01
Geographical factors have an impact on the utilisation of out-of-hours services. In this study we have investigated the travel distance to out-of-hours casualty clinics in Norwegian municipalities in 2011 and the number of municipalities covered by the proposed recommendations for secondary on-call arrangements due to long distances. We estimated the average maximum travel times and distances in Norwegian municipalities using a postcode-based method. Separate analyses were performed for municipalities with a single, permanently located casualty clinic. Altogether 417 out of 430 municipalities were included. We present the median value of the maximum travel times and distances for the included municipalities. The median maximum average travel distance for the municipalities was 19 km. The median maximum average travel time was 22 minutes. In 40 of the municipalities (10 %) the median maximum average travel time exceeded 60 minutes, and in 97 municipalities (23 %) the median maximum average travel time exceeded 40 minutes. The population of these groups comprised 2 % and 5 % of the country's total population respectively. For municipalities with permanent emergency facilities(N = 316), the median average flight time 16 minutes and median average distance 13 km.. In many municipalities, the inhabitants have a long average journey to out-of-hours emergency health services, but seen as a whole, the inhabitants of these municipalities account for a very small proportion of the Norwegian population. The results indicate that the proposed recommendations for secondary on-call duty based on long distances apply to only a small number of inhabitants. The recommendations should therefore be adjusted and reformulated to become more relevant.
Comparison of the WSA-ENLIL model with three CME cone types
NASA Astrophysics Data System (ADS)
Jang, Soojeong; Moon, Y.; Na, H.
2013-07-01
We have made a comparison of the CME-associated shock propagation based on the WSA-ENLIL model with three cone types using 29 halo CMEs from 2001 to 2002. These halo CMEs have cone model parameters as well as their associated interplanetary (IP) shocks. For this study we consider three different cone types (an asymmetric cone model, an ice-cream cone model and an elliptical cone model) to determine 3-D CME parameters (radial velocity, angular width and source location), which are the input values of the WSA-ENLIL model. The mean absolute error (MAE) of the arrival times for the asymmetric cone model is 10.6 hours, which is about 1 hour smaller than those of the other models. Their ensemble average of MAE is 9.5 hours. However, this value is still larger than that (8.7 hours) of the empirical model of Kim et al. (2007). We will compare their IP shock velocities and densities with those from ACE in-situ measurements and discuss them in terms of the prediction of geomagnetic storms.Abstract (2,250 Maximum Characters): We have made a comparison of the CME-associated shock propagation based on the WSA-ENLIL model with three cone types using 29 halo CMEs from 2001 to 2002. These halo CMEs have cone model parameters as well as their associated interplanetary (IP) shocks. For this study we consider three different cone types (an asymmetric cone model, an ice-cream cone model and an elliptical cone model) to determine 3-D CME parameters (radial velocity, angular width and source location), which are the input values of the WSA-ENLIL model. The mean absolute error (MAE) of the arrival times for the asymmetric cone model is 10.6 hours, which is about 1 hour smaller than those of the other models. Their ensemble average of MAE is 9.5 hours. However, this value is still larger than that (8.7 hours) of the empirical model of Kim et al. (2007). We will compare their IP shock velocities and densities with those from ACE in-situ measurements and discuss them in terms of the prediction of geomagnetic storms.
NASA Astrophysics Data System (ADS)
Shaw, Patrick
The Dust REgional Atmospheric Model (DREAM) predicts concentrations of mineral dust aerosols in time and space, but validation is challenging with current in situ particulate matter (PM) concentration measurements. Measured levels of ambient PM often contain anthropogenic components as well as windblown mineral dust. In this study, two approaches to model validation were performed with data from preexisting air quality monitoring networks: using hourly concentrations of total PM with aerodynamic diameter less than 2.5 μm (PM 2.5); and using a daily averaged speciation-derived soil component. Validation analyses were performed for point locations within the cities of El Paso (TX), Austin (TX), Phoenix (AZ), Salt Lake City (UT) and Bakersfield (CA) for most of 2006. Hourly modeled PM 2.5 did not validate at all with hourly observations among the sites (combined R < 0.00, N = 24,302 hourly values). Aerosol chemical speciation data distinguished between mineral (soil) dust from anthropogenic ambient PM. As expected, statistically significant improvements in correlation among all stations (combined R = 0.16, N = 343 daily values) were found when the soil component alone was used to validate DREAM. The validation biases that result from anthropogenic aerosols were also reduced using the soil component. This is seen in the reduction of the root mean square error between hourly in situ versus hourly modeled (RMSE hourly = 18.6 μg m -3) and 24-h in situ speciation values versus daily averaged observed (RMSE soil = 12.0 μg m -3). However, the lack of a total reduction in RMSE indicates there is still room for improvement in the model. While the soil component is the theoretical proxy of choice for a dust transport model, the current sparse and infrequent sampling is not ideal for routine hourly air quality forecast validation.
Prospective cohort study on noise levels in a pediatric cardiac intensive care unit.
Garcia Guerra, Gonzalo; Joffe, Ari R; Sheppard, Cathy; Pugh, Jodie; Moez, Elham Khodayari; Dinu, Irina A; Jou, Hsing; Hartling, Lisa; Vohra, Sunita
2018-04-01
To describe noise levels in a pediatric cardiac intensive care unit, and to determine the relationship between sound levels and patient sedation requirements. Prospective observational study at a pediatric cardiac intensive care unit (PCICU). Sound levels were measured continuously in slow A weighted decibels dB(A) with a sound level meter SoundEarPro® during a 4-week period. Sedation requirement was assessed using the number of intermittent (PRNs) doses given per hour. Analysis was conducted with autoregressive moving average models and the Granger test for causality. 39 children were included in the study. The average (SD) sound level in the open area was 59.4 (2.5) dB(A) with a statistically significant but clinically unimportant difference between day/night hours (60.1 vs. 58.6; p-value < 0.001). There was no significant difference between sound levels in the open area/single room (59.4 vs. 60.8, p-value = 0.108). Peak noise levels were > 90 dB. There was a significant association between average (p-value = 0.030) and peak sound levels (p-value = 0.006), and number of sedation PRNs. Sound levels were above the recommended values with no differences between day/night or open area/single room. High sound levels were significantly associated with sedation requirements. Copyright © 2017 Elsevier Inc. All rights reserved.
Noise level in a neonatal intensive care unit in Santa Marta - Colombia.
Garrido Galindo, Angélica Patricia; Velez-Pereira, Andres M
2017-01-01
Abstract Introduction: The environment of neonatal intensive care units is influenced by numerous sources of noise emission, which contribute to raise the noise levels, and may cause hearing impairment and other physiological and psychological changes on the newborn, as well as problems with care staff. Objective: To evaluate the level and sources of noise in the neonatal intensive care unit. Methods: Sampled for 20 consecutive days every 60 seconds in A-weighting curves and fast mode with a Type I sound level meter. Recorded the average, maximum and minimum, and the 10th, 50th and 90th percentiles. The values are integrated into hours and work shift, and studied by analysis of variance. The sources were characterized in thirds of octaves. Results: The average level was 64.00 ±3.62 dB(A), with maximum of 76.04 ±5.73 dB(A), minimum of 54.84 ±2.61dB(A), and background noise of 57.95 ±2.83 dB(A). We found four sources with levels between 16.8-63.3 dB(A). Statistical analysis showed significant differences between the hours and work shift, with higher values in the early hours of the day. Conclusion: The values presented exceed the standards suggested by several organizations. The sources identified and measured recorded high values in low frequencies. PMID:29213154
NASA Astrophysics Data System (ADS)
Malley, Christopher S.; von Schneidemesser, Erika; Moller, Sarah; Braban, Christine F.; Hicks, W. Kevin; Heal, Mathew R.
2018-03-01
Exposure to nitrogen dioxide (NO2) is associated with negative human health effects, both for short-term peak
concentrations and from long-term exposure to a wider range of NO2 concentrations. For the latter, the European Union has established an air quality limit value of 40 µg m-3 as an annual average. However, factors such as proximity and strength of local emissions, atmospheric chemistry, and meteorological conditions mean that there is substantial variation in the hourly NO2 concentrations contributing to an annual average concentration. The aim of this analysis was to quantify the nature of this variation at thousands of monitoring sites across Europe through the calculation of a standard set of chemical climatology
statistics. Specifically, at each monitoring site that satisfied data capture criteria for inclusion in this analysis, annual NO2 concentrations, as well as the percentage contribution from each month, hour of the day, and hourly NO2 concentrations divided into 5 µg m-3 bins were calculated. Across Europe, 2010-2014 average annual NO2 concentrations (NO2AA) exceeded the annual NO2 limit value at 8 % of > 2500 monitoring sites. The application of this chemical climatology
approach showed that sites with distinct monthly, hour of day, and hourly NO2 concentration bin contributions to NO2AA were not grouped into specific regions of Europe, furthermore, within relatively small geographic regions there were sites with similar NO2AA, but with differences in these contributions. Specifically, at sites with highest NO2AA, there were generally similar contributions from across the year, but there were also differences in the contribution of peak vs. moderate hourly NO2 concentrations to NO2AA, and from different hours across the day. Trends between 2000 and 2014 for 259 sites indicate that, in general, the contribution to NO2AA from winter months has increased, as has the contribution from the rush-hour periods of the day, while the contribution from peak hourly NO2 concentrations has decreased. The variety of monthly, hour of day and hourly NO2 concentration bin contributions to NO2AA, across cities, countries and regions of Europe indicate that within relatively small geographic areas different interactions between emissions, atmospheric chemistry and meteorology produce variation in NO2AA and the conditions that produce it. Therefore, measures implemented to reduce NO2AA in one location may not be as effective in others. The development of strategies to reduce NO2AA for an area should therefore consider (i) the variation in monthly, hour of day, and hourly NO2 concentration bin contributions to NO2AA within that area; and (ii) how specific mitigation actions will affect variability in hourly NO2 concentrations.
Reynolds Number Scaling and Parameterization of Stratified Turbulent Wakes
2017-04-17
orbital shape remains repeatable from one wave cycle to the next. Depth- averaged values of the mean and rms IWB-mean Lagrangian drifts (not shown here...suggest that these drifts will be accompanied by average particle displacements of CJ = (10KxT)112 = 10- 1 .AJ = :::o:O(lOm). Our fmdings on Lagrangian ...of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching data sources, gathering and
Evaluation of the normal range of values for uptake of radioactive iodine by the thyroid gland.
Schober, B.; Hunt, J. A.
1976-01-01
Uptake of radioactive iodine by the thyroid gland after oral administration of 75 muCi was determined in 1971-72 in 60 euthyroid female volunteers from the North Shore of Vancouver. Values were as low as 3% at 4 hours and 7% at 24 hours in subjects otherwise proven to be euthyroid. The highest values found were 13 and 26% at 4 and 24 hours. The effective thyroxine ratios were all within the accepted normal range. However, more than half of the volunteers showed some enlargement of the thyroid gland. These results suggest an increased iodine pool in the subjects, the likley source being iodine in mild, dairy products and erythrosine, a colouring agent in foods and pharmaceutical products. Potassium iodate, used sometimes in bread baking, contributed little to this pool in our sample. Subjects were, on the average, 9 to 25% heavier than their peers 20 years ago. PMID:1277057
Mars Global Reference Atmospheric Model (Mars-GRAM) and Database for Mission Design
NASA Technical Reports Server (NTRS)
Justus, C. G.; Duvall, Aleta; Johnson, D. L.
2003-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model, while above 80 km it is based on Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter. Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science and Thermal Emission Spectrometer data. RS data from 2480 profiles were used, covering latitudes 75 deg S to 72 deg N, surface to approximately 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160 deg and 265-310 deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, RS density varied by about a factor of 2.5 over ranges of latitudes and Ls values observed. Evaluated at matching positions and times, these figures show average RSMars-GRAM density ratios were generally 1+/-)0.05, except at heights above approximately 25 km and latitudes above approximately 50 deg N. Average standard deviation of RSMars-GRAM density ratio was 6%. TES data were used covering surface to approximately 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). Depending on season, TES data covered latitudes 85 deg S to 85 deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (greater than 45 deg N), or at most altitudes in the southern hemisphere at Ls approximately 90 and 180 deg. Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approximately 2.5% for all data, or approximately 1-4%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about three times the standard deviation of TES data about the TES mean value at a given position and season.
Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J
1994-12-01
Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.
Is it possible to shorten ambulatory blood pressure monitoring?
Wolak, Talya; Wilk, Lior; Paran, Esther; Wolak, Arik; Gutmacher, Bella; Shleyfer, Elena; Friger, Michael
2013-08-01
The aim of this investigation was to find a time segment in which average blood pressure (BP) has the best correlation with 24-hour BP control. A total of 240 patients with full ambulatory BP monitoring (ABPM) were included; 120 had controlled BP (systolic BP [SBP] ≤135 mm Hg and diastolic BP [DBP] ≤85 mm Hg) and 120 had uncontrolled BP (SBP >135 mm Hg and/or DBP >85 mm Hg). Each ABPM was divided into 6- and 8-hour segments. Evaluation for correlation between mean BP for each time segment and 24-hour BP control was performed using receiver operating characteristic curve analysis and Youden's index for threshold with the best sensitivity and specificity. The mean BP in the following segments showed the highest area under the curve (AUC) compared with average controlled 24-hour BP: SBP 2 am to 8 am (AUC, 0.918; threshold value of 133.5 mm Hg, sensitivity-0.752 and specificity-0.904); SBP 2 pm to 10 pm (AUC, 0.911; threshold value of 138.5 mm Hg, sensitivity-0.803 and specificity-0.878); and SBP 6 am to 2 pm (AUC, 0.903; threshold value of 140.5 mm Hg, sensitivity-0.778 and specificity-0.888). The time segment 2 pm to 10 pm was shown to have good correlation with 24-hour BP control (AUC >0.9; sensitivity and specificity >80%). This time segment might replace full ABPM as a screening measure for BP control or as abbreviated ABPM for patients with difficulty in performing full ABPM. © 2013 Wiley Periodicals, Inc.
Market potential of mesquite as fuel
A.T. Wiley; F.G. Manwiller
1976-01-01
The heat of combustion of mesquite heartwood, sapwood, bark, and a mixture of stems and leaves was tested. The values averaged 8,657, 8,021, 7,836, and 8,123 Btu per OD pound, respectively. If an industrial plant requiring 50,000 pounds of steam per hour were located in an area averaging 25 green tons of mesquite fiber per acre, a harvest radius of about 3 miles would...
Market potential of mesquite as fuel
A.T. Wiley; F.G. Manwiller
1976-01-01
The heat combustion of mesquite heartwood, aspwood, bark, and a mixture of stems and leaves was tested. The values averaged 8,657, 8,021, 7,836, and 8,123 Btu per OD pound, respectively. If an industrial plant requiring 50,000 pounds of steam per hour were located in an area averaging 25 green tons of mesquite fiber per acre, a harvest radius of about 3 miles would be...
Pulse charging of lead-acid traction cells
NASA Technical Reports Server (NTRS)
Smithrick, J. J.
1980-01-01
Pulse charging, as a method of rapidly and efficiently charging 300 amp-hour lead-acid traction cells for an electric vehicle application was investigated. A wide range of charge pulse current square waveforms were investigated and the results were compared to constant current charging at the time averaged pulse current values. Representative pulse current waveforms were: (1) positive waveform-peak charge pulse current of 300 amperes (amps), discharge pulse-current of zero amps, and a duty cycle of about 50%; (2) Romanov waveform-peak charge pulse current of 300 amps, peak discharge pulse current of 15 amps, and a duty of 50%; and (3) McCulloch waveform peak charge pulse current of 193 amps, peak discharge pulse current of about 575 amps, and a duty cycle of 94%. Experimental results indicate that on the basis of amp-hour efficiency, pulse charging offered no significant advantage as a method of rapidly charging 300 amp-hour lead-acid traction cells when compared to constant current charging at the time average pulse current value. There were, however, some disadvantages of pulse charging in particular a decrease in charge amp-hour and energy efficiencies and an increase in cell electrolyte temperature. The constant current charge method resulted in the best energy efficiency with no significant sacrifice of charge time or amp-hour output. Whether or not pulse charging offers an advantage over constant current charging with regard to the cell charge/discharge cycle life is unknown at this time.
The Effect of Technological Devices on Cervical Lordosis.
Öğrenci, Ahmet; Koban, Orkun; Yaman, Onur; Dalbayrak, Sedat; Yılmaz, Mesut
2018-03-15
There is a need for cervical flexion and even cervical hyperflexion for the use of technological devices, especially mobile phones. We investigated the effect of this use on the cervical lordosis angle. A group of 156 patients who applied with only neck pain between 2013-2016 and had no additional problems were included. Patients are specifically questioned about mobile phone, tablet, and other devices usage. The value obtained by multiplying the year of usage and the average usage (hour) in daily life was determined as the total usage value (an average hour per day x year: hy). Cervical lordosis angles were statistically compared with the total time of use. In the general ROC analysis, the cut-off value was found to be 20.5 hy. When the cut-off value is tested, the overall accuracy is very good with 72.4%. The true estimate of true risk and non-risk is quite high. The ROC analysis is statistically significant. The use of computing devices, especially mobile telephones, and the increase in the flexion of the cervical spine indicate that cervical vertebral problems will increase even in younger people in future. Also, to using with attention at this point, ergonomic devices must also be developed.
NASA Technical Reports Server (NTRS)
Baevsky, R. M.; Bennett, B. S.; Bungo, M. W.; Charles, J. B.; Goldberger, A. L.; Nikulina, G. A.
1997-01-01
This article presents selected findings obtained with Holter monitoring from two crew members of the expedition, performed during a 175-day space mission on board orbital space station "MIR." Using mathematical processing of daily cardiointervals files, 5-minute sections of records were analyzed consecutively. Then, the average daily values of indices, the average-per-every-eight-hours values (morning, evening, night) and mean values per hour were computed. The results of analysis showed that prolonged exposure of man to microgravity conditions leads to important functional alteration in human neuroautonomic regulatory mechanisms. Both crew members had significant increase of heart rate, the rise of stress index, the decrease in power of the spectrum in the range of respiratory sinus arrhythmia. These marked signs of activation of the sympathetic section of the vegetative nervous system showed individual variations. The analysis of the daily collection of cardiointervals with Holter monitoring allows us to understand and forecast the functional feasibilities of the human organism under a variety of stress conditions associated with acute and chronic microgravity exposure.
Mena, Luis J; Felix, Vanessa G; Melgarejo, Jesus D; Maestre, Gladys E
2017-10-19
Although 24-hour blood pressure (BP) variability (BPV) is predictive of cardiovascular outcomes independent of absolute BP levels, it is not regularly assessed in clinical practice. One possible limitation to routine BPV assessment is the lack of standardized methods for accurately estimating 24-hour BPV. We conducted a systematic review to assess the predictive power of reported BPV indexes to address appropriate quantification of 24-hour BPV, including the average real variability (ARV) index. Studies chosen for review were those that presented data for 24-hour BPV in adults from meta-analysis, longitudinal or cross-sectional design, and examined BPV in terms of the following issues: (1) methods used to calculate and evaluate ARV; (2) assessment of 24-hour BPV determined using noninvasive ambulatory BP monitoring; (3) multivariate analysis adjusted for covariates, including some measure of BP; (4) association of 24-hour BPV with subclinical organ damage; and (5) the predictive value of 24-hour BPV on target organ damage and rate of cardiovascular events. Of the 19 assessed studies, 17 reported significant associations between high ARV and the presence and progression of subclinical organ damage, as well as the incidence of hard end points, such as cardiovascular events. In all these cases, ARV remained a significant independent predictor ( P <0.05) after adjustment for BP and other clinical factors. In addition, increased ARV in systolic BP was associated with risk of all cardiovascular events (hazard ratio, 1.18; 95% confidence interval, 1.09-1.27). Only 2 cross-sectional studies did not find that high ARV was a significant risk factor. Current evidence suggests that ARV index adds significant prognostic information to 24-hour ambulatory BP monitoring and is a useful approach for studying the clinical value of BPV. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Analyses of ozone in urban and rural sites in Málaga (Spain).
Dueñas, C; Fernández, M C; Cañete, S; Carretero, J; Liger, E
2004-08-01
Ozone concentrations were measured at two (urban and a rural) sites near the city of Málaga (Spain). The aim of this study was to determine the daily, monthly and seasonal variation patterns of ozone concentrations at both sites and to study the possible regional influences. The daily variations mostly have the usual features with the afternoon maximum and the night minimum being more pronounced in the urban area. The average monthly concentrations throughout the year start to increase in March reaching their maximum values in July for the urban site. However, in the rural area, the monthly variations are smaller reaching their maximum value in June. The hourly evolution of the ozone concentrations in both sampling sites is well defined in spring and summer and not so well defined in autumn and winter. Taking into account the four seasons, the rural concentrations are higher than the urban ones. Summer is the season when there are similar concentrations at both sampling sites. Average hourly summer afternoon ozone for the hours 12:00-20:00 LST exceeded the 110 microg m(-3) European Union guidelines for human health for 8 h ozone exposure at the urban and rural sites.
NASA Astrophysics Data System (ADS)
1982-02-01
Performance data for the month of January, 1982 for a grid connected photovoltaic power supply in Massachusetts are presented. Data include: monthly and daily electrical energy produced; monthly and daily solar energy incident on the array; monthly and daily array efficiency; plots of energy produced as a function of power level, voltage, cell temperature and time of day; power conditioner input, output and efficiency for each of two individual units and for the total power conditioning system; photovoltaic system efficiency; capacity factor; PV system to load and grid to load energies and corresponding dollar values; daily energy supplies to the load by the PV system; daily PV system availability; monthly and hourly insolation; monthly and hourly temperature average; monthly and hourly wind speed; wind direction distribution; average heating and cooling degree days; number of freeze/thaw cycles; and the data acquisition mode and recording interval plot.
Aydin, Hasan R; Irkilata, Lokman; Aydin, Mustafa; Daggulli, Mansur; Taskin, Mehmet H; Demirel, Huseyin C; Adanur, Senol; Moral, Caner; Atilla, Mustafa K; Sancaktutar, Ahmet A
2016-01-01
We aimed to evaluate the role of kidney injury molecule-1 (KIM-1) in determining the intervals between shockwave lithotripsy (SWL) sessions. This was a prospective, controlled study. It included 40 patients with unilateral kidney stones and 40 healthy persons of a similar age group as controls. The patients' midflow urine samples were collected before SWL and 1 hour, 1 day, 1 week, and 1 month after the procedure. The average age in the SWL and control groups was 45 ± 14 and 39 ± 15 years, respectively (P = 0.336). The average KIM-1 value before SWL was 0.74 ± 0.35 ng/mL, which was significantly higher than that of the control group (0.51 ± 0.14 ng/mL) (P < 0.001). Similarly, the average values of the urine samples after SWL were higher than those of the control group (P < 0.001). When the KIM-1 values of the patients given SWL were compared within the group, the KIM-1 values 1 hour (1.06 ± 0.51) and 1 day (0.99 ± 0.67) after the procedure were statistically clearly higher than those before the procedure (P < 0.001) and statistically clearly higher than those of the control group (P = 0.005). The KIM-1 values 1 week and 1 month after the procedure were not significantly different than the preprocedure values (P = 0.652 and P = 0.747, respectively). KIM-1 is a noninvasive biomarker that may be used to show renal damage because of stones and early-stage renal damage linked to SWL. In addition, post-SWL KIM-1 values may be used to determine the interval between SWL sessions.
A real world analysis of payment per unit time in a Maryland Vascular Practice.
Martin, John D; Warble, Patricia B; Hupp, Jon A; Mapes, Jerry E; Stanziale, Stephen F; Weiss, Linda L; Schiller, Toni B; Hanson, Louise A
2010-10-01
In 1992, Centers for Medicare and Medicaid Services instituted the Resource Based Relative Value Scale (RBRVS) system to determine physician reimbursement. Relative value units (RVU) were assigned to each Current Procedure Terminology (CPT) code and intended to reflect the time and intensity of work. Little data exist correlating actual procedural and clinical time with respect to reimbursement within the RVU value system. The purpose of this study was to determine how well this system distributes payments per hour for hospital-based procedures in a single vascular practice in the state of Maryland between July 1, 2008 and June 30, 2009. As part of an ongoing prospective outcomes program, procedural times for all vascular procedures (time into until time out of room) were recorded. Fifteen minutes were added for administrative functions on procedural day, each hospital day, and office visits during the global period. The combination of all times was reflected in the total care time (TCT) for each procedure. We recorded all physician fees collected for each procedure. This total fee collected for each procedure was then divided by the TCT to determine the procedure-specific payment per unit time. All similar procedures were grouped together and the average reimbursement per procedure was reported. Data was collected on all 1103 procedures performed during this period. Insurance carrier distribution was 75% Medicare and 25% private insurance. The average reimbursement was $316/hour for open procedures and $556/hour for endovascular. Higher reimbursing procedures included visceral endovascular procedures ($701/hour) and caval filters ($751/hour). Lower reimbursing procedures included lower extremity bypass ($292/hour), dialysis access ($268/hour) and lower extremity amputations ($223/hour). Striking was the difference between payment based on approach for similar conditions. Reimbursement for carotid stent vs carotid endarterectomy was $643/hour vs $383/hour, endovascular abdominal aortic aneurysm (AAA) repair vs open $593/hour vs $359/hour. This unique study demonstrates a "real world" experience of reimbursement per unit time and raises questions as to the validity of the RBRVS process. The disparity between payments for open and endovascular repair of similar conditions are typical of this inequality. These data do not reflect the intangible time of operative planning, administrative matters, or overhead, and these factors must be considered when interpreting this data. Regardless, this study suggests that capturing detailed financial data is possible and is a more accurate source for future discussions on reimbursement. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janjai, Serm
In order to investigate a potential use of concentrating solar power technologies and select an optimum site for these technologies, it is necessary to obtain information on the geographical distribution of direct normal solar irradiation over an area of interest. In this work, we have developed a method for estimating direct normal irradiation from satellite data for a tropical environment. The method starts with the estimation of global irradiation on a horizontal surface from MTSAT-1R satellite data and other ground-based ancillary data. Then a satellite-based diffuse fraction model was developed and used to estimate the diffuse component of the satellite-derivedmore » global irradiation. Based on this estimated global and diffuse irradiation and the solar radiation incident angle, the direct normal irradiation was finally calculated. To evaluate its performance, the method was used to estimate the monthly average hourly direct normal irradiation at seven pyrheliometer stations in Thailand. It was found that values of monthly average hourly direct normal irradiation from the measurements and those estimated from the proposed method are in reasonable agreement, with a root mean square difference of 16% and a mean bias of -1.6%, with respect to mean measured values. After the validation, this method was used to estimate the monthly average hourly direct normal irradiation over Thailand by using MTSAT-1R satellite data for the period from June 2005 to December 2008. Results from the calculation were displayed as hourly and yearly irradiation maps. These maps reveal that the direct normal irradiation in Thailand was strongly affected by the tropical monsoons and local topography of the country. (author)« less
Selected meteorological data for an arid site near Beatty, Nye County, Nevada, calendar year 1988
Wood, James L.; Hill, Kevin J.; Andraski, Brian J.
1992-01-01
Selected meteorological data were collected at a study site adjacent to a low-level radioactive-waste burial facility near Beatty/ Nevada, for calendar year 1988. Data were collected in support of ongoing studies to estimate the potential for downward movement of radionuclides into the unsaturated sediments beneath waste-burial trenches at the facility. The data include air temperature, relative humidity, vapor pressure, incident solar radiation, windspeed, wind direction, and precipitation. The data are summarized in tables and graphs.Instrumentation used at the site is discussed. The discussion includes the type, reported accuracy, and mounting height of each sensor.In 1988, the average hourly air temperatures ranged from -10.2 degrees Celsius, in December, to 45.3 degrees Celsius, in July. Hourly averaged relative humidity ranged from about 12 percent to over 80 percent. Hourly vapor pressures ranged from 0.09 to 2.22 kilopascals. Daily values for maximum incident solar radiation ranged from 63 to 1,064 watts per square meter. Daily mean windspeed ranged from 1.2 to 7.8 meters per second. Monthly wind-direction patterns are shown in a series of diagrams in which wind direction is summed over 10-degree arcs from hourly averaged data. Total precipitation for 1988 was 104.5 millimeters, with over 70 percent occurring from January through May.
Mars-Gram Validation with Mars Global Surveyor Data
NASA Technical Reports Server (NTRS)
Justus, C. G.; Johnson, D.; Parker, Nelson C. (Technical Monitor)
2002-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many b4ars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model (MGCM), while above 80 km it is based on University of Arizona Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter (MOLA). Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science (RS) and Thermal Emission Spectrometer (TES) data. RS data from 2480 profiles were used, covering latitudes 75deg S to 72deg N, surface to approx. 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160deg and 265-310deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, measured RS density varied by about a factor of 2.5 over the range of latitudes and Ls values observed. Evaluated at matching positions and times, average RS/Mars-GRAM density ratios were generally lf0.05, except at heights above approx. 25 km and latitudes above approx.50deg N. Average standard deviation of RS/Mars-GRAM density ratio was 6%. TES data were used covering surface to approx. 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of Mars global dust storm). Depending on season, TES data covered latitudes 85deg S to 85deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (> 45deg N), or at most altitudes in the southern hemisphere at Ls approx. 90 and 180deg). Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approx. 6.5-10.5% (varying with height) for all data, or approx. 5- 12%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for 1o:al time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about the same as the standard deviation of TES data about the TES mean value at a given position and season.
Amann, Rupert P; Chapman, Phillip L
2009-01-01
We retrospectively mined and modeled data to answer 3 questions. 1) Relative to an estimate based on approximately 20 semen samples, how imprecise is an estimate of an individual's total sperm per ejaculate (TSperm) based on 1 sample? 2) What is the impact of abstinence interval on TSperm and TSperm/h? 3) How many samples are needed to provide a meaningful estimate of an individual's mean TSperm or TSperm/h? Data were for 18-20 consecutive masturbation samples from each of 48 semen donors. Modeling exploited the gamma distribution of values for TSperm and a unique approach to project to future samples. Answers: 1) Within-individual coefficients of variation were similar for TSperm or TSperm/h abstinence and ranged from 17% to 51%; average approximately 34%. TSperm or TSperm/h in any individual sample from a given donor was between -20% and +20% of the mean value in 48% of 18-20 samples per individual. 2) For a majority of individuals, TSperm increased in a nearly linear manner through approximately 72 hours of abstinence. TSperm and TSperm/h after 18-36 hours' abstinence are high. To obtain meaningful values for diagnostic purposes and maximize distinction of individuals with relatively low or high sperm production, the requested abstinence should be 42-54 hours with an upper limit of 64 hours. For individuals producing few sperm, 7 days or more of abstinence might be appropriate to obtain sperm for insemination. 3) At least 3 samples from a hypothetical future subject are recommended for most applications. Assuming 60 hours' abstinence, 80% confidence limits for TSperm/h for 1, 3, or 6 samples would be 70%-163%, 80%-130%, or 85%-120% of the mean for observed values. In only approximately 50% of cases would TSperm/h for a single sample be within -16% and +30% of the true mean value for that subject. Pooling values for TSperm in samples obtained after 18-36 or 72-168 hours' abstinence with values for TSperm obtained after 42-64 hours is inappropriate. Reliance on TSperm for a single sample per subject is unwise.
40 CFR Table 8 to Subpart Sssss of... - Continuous Compliance with Operating Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart; andii. Reducing the scrubber pressure drop data to 1-hour and 3-hour block averages; and iii.... Reducing the scrubber liquid pH data to 1-hour and 3-hour block averages; and iii. Maintaining the 3-hour... subpart; andii. Reducing the scrubber liquid flow rate data to 1-hour and 3-hour block averages; and iii...
40 CFR 50.5 - National secondary ambient air quality standard for sulfur oxides (sulfur dioxide).
Code of Federal Regulations, 2011 CFR
2011-07-01
... average must be based upon hourly data that are at least 75 percent complete in each calendar quarter. A 3... the level of the standard when zeros are substituted for the missing values, subject to the rounding...
40 CFR 50.5 - National secondary ambient air quality standard for sulfur oxides (sulfur dioxide).
Code of Federal Regulations, 2010 CFR
2010-07-01
... average must be based upon hourly data that are at least 75 percent complete in each calendar quarter. A 3... the level of the standard when zeros are substituted for the missing values, subject to the rounding...
AIP1OGREN: Aerosol Observing Station Intensive Properties Value-Added Product
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koontz, Annette; Flynn, Connor
The aip1ogren value-added product (VAP) computes several aerosol intensive properties. It requires as input calibrated, corrected, aerosol extensive properties (scattering and absorption coefficients, primarily) from the Aerosol Observing Station (AOS). Aerosol extensive properties depend on both the nature of the aerosol and the amount of the aerosol. We compute several properties as relationships between the various extensive properties. These intensive properties are independent of aerosol amount and instead relate to intrinsic properties of the aerosol itself. Along with the original extensive properties we report aerosol single-scattering albedo, hemispheric backscatter fraction, asymmetry parameter, and Ångström exponent for scattering and absorption withmore » one-minute averaging. An hourly averaged file is produced from the 1-minute files that includes all extensive and intensive properties as well as submicron scattering and submicron absorption fractions. Finally, in both the minutely and hourly files the aerosol radiative forcing efficiency is provided.« less
Michael, Claire W; Naik, Kalyani; McVicker, Michael
2013-05-01
We developed a value stream map (VSM) of the Papanicolaou test procedure to identify opportunities to reduce waste and errors, created a new VSM, and implemented a new process emphasizing Lean tools. Preimplementation data revealed the following: (1) processing time (PT) for 1,140 samples averaged 54 hours; (2) 27 accessioning errors were detected on review of 357 random requisitions (7.6%); (3) 5 of the 20,060 tests had labeling errors that had gone undetected in the processing stage. Four were detected later during specimen processing but 1 reached the reporting stage. Postimplementation data were as follows: (1) PT for 1,355 samples averaged 31 hours; (2) 17 accessioning errors were detected on review of 385 random requisitions (4.4%); and (3) no labeling errors were undetected. Our results demonstrate that implementation of Lean methods, such as first-in first-out processes and minimizing batch size by staff actively participating in the improvement process, allows for higher quality, greater patient safety, and improved efficiency.
Pires, J C M; Gonçalves, B; Azevedo, F G; Carneiro, A P; Rego, N; Assembleia, A J B; Lima, J F B; Silva, P A; Alves, C; Martins, F G
2012-09-01
This study proposes three methodologies to define artificial neural network models through genetic algorithms (GAs) to predict the next-day hourly average surface ozone (O(3)) concentrations. GAs were applied to define the activation function in hidden layer and the number of hidden neurons. Two of the methodologies define threshold models, which assume that the behaviour of the dependent variable (O(3) concentrations) changes when it enters in a different regime (two and four regimes were considered in this study). The change from one regime to another depends on a specific value (threshold value) of an explanatory variable (threshold variable), which is also defined by GAs. The predictor variables were the hourly average concentrations of carbon monoxide (CO), nitrogen oxide, nitrogen dioxide (NO(2)), and O(3) (recorded in the previous day at an urban site with traffic influence) and also meteorological data (hourly averages of temperature, solar radiation, relative humidity and wind speed). The study was performed for the period from May to August 2004. Several models were achieved and only the best model of each methodology was analysed. In threshold models, the variables selected by GAs to define the O(3) regimes were temperature, CO and NO(2) concentrations, due to their importance in O(3) chemistry in an urban atmosphere. In the prediction of O(3) concentrations, the threshold model that considers two regimes was the one that fitted the data most efficiently.
2013-04-17
Schwartz Steven J . Schwartz 633001 c. THIS PAGE The public reporting burden for this collection of information is estimated to average 1 hour per...Barbosa-Canovas, V.M. Balasubramaniam, P. Dunne, D. Farkas, J . Yuan. Handbook of Nonthermal Processing Technologies for Food, Chicago: IFT Press...thermogram. The average values for latent heat of melting for SLN, 1% NLC and 10% NLC were 134.78, 121.1, 80.2 J /g respectively. Based on the ratio of the
Assessment of a Pharmaceutical Advertisement Analysis Module in a Drug Literature Evaluation Course.
Amin, Mohamed Ezzat Khamis; Fattouh, Youssef
2017-08-01
Objective. To evaluate the impact of an educational module on students' self-efficacy when analyzing the content of promotional drug brochures (PDBs) and to assess the students' value of PDBs' as an educational tool. Methods. Third-year bachelor of pharmacy students participated in a one-hour lecture and a two-hour laboratory. Students completed a survey before and after participating in the module. Results. The module elicited a statistically significant change in students' self-efficacy beliefs regarding evaluating promotional drug brochures, while the average perceived value of promotional drug brochures did not change significantly after the module. Conclusion. A brief educational module can increase students' self-efficacy in evaluating the content of PDBs.
The Effect of Technological Devices on Cervical Lordosis
Öğrenci, Ahmet; Koban, Orkun; Yaman, Onur; Dalbayrak, Sedat; Yılmaz, Mesut
2018-01-01
PURPOSE: There is a need for cervical flexion and even cervical hyperflexion for the use of technological devices, especially mobile phones. We investigated the effect of this use on the cervical lordosis angle. MATERIAL AND METHODS: A group of 156 patients who applied with only neck pain between 2013–2016 and had no additional problems were included. Patients are specifically questioned about mobile phone, tablet, and other devices usage. The value obtained by multiplying the year of usage and the average usage (hour) in daily life was determined as the total usage value (an average hour per day x year: hy). Cervical lordosis angles were statistically compared with the total time of use. RESULTS: In the general ROC analysis, the cut-off value was found to be 20.5 hy. When the cut-off value is tested, the overall accuracy is very good with 72.4%. The true estimate of true risk and non-risk is quite high. The ROC analysis is statistically significant. CONCLUSION: The use of computing devices, especially mobile telephones, and the increase in the flexion of the cervical spine indicate that cervical vertebral problems will increase even in younger people in future. Also, to using with attention at this point, ergonomic devices must also be developed. PMID:29610602
Evaluation results of the 700 deg C Chinese strain gauges. [for gas turbine engine
NASA Technical Reports Server (NTRS)
Hobart, H. F.
1985-01-01
Gauges fabricated from specially developed Fe-Cr-Al-V-Ti-Y alloy wire in the Republic of China were evaluated for use in static strain measurement of hot gas turbine engines. Gauge factor variation with temperature, apparent strain, and drift were included. Results of gauge factor versus temperature tests show gauge factor decreasing with increasing temperature. The average slope is -3-1/2 percent/100 K, with an uncertainty band of + or - 8 percent. Values of room temperature gauge factor for the Chinese and Kanthal A-1 gauges averaged 2.73 and 2.12, respectively. The room temperature gauge factor of the Chinese gauges was specified to be 2.62. The apparent strain data for both the Chinese alloy and Kanthal A-1 showed large cycle to cycle nonrepeatability. All apparent strain curves had a similar S-shape, first going negative and then rising to positive value with increasing temperatures. The mean curve for the Chinese gauges between room temperature and 100 K had a total apparent strain of 1500 microstrain. The equivalent value for Kanthal A-1 was about 9000 microstrain. Drift tests at 950 K for 50 hr show an average drift rate of about -9 microstrain/hr. Short-term (1 hr) rates are higher, averaging about -40 microstrain for the first hour. In the temperature range 700 to 870 K, however, short-term drift rates can be as high as 1700 microstrain for the first hour. Therefore, static strain measurements in this temperature range should be avoided.
[Evaluation of continuing medical training in private sector French cardiologists in 1999].
Thébaut, J F; Chabot, J M; Durand, J P; Childs, M; Assouline, S; Breton, C; Fraboulet, J Y; Sebaoun, A; Aviérinos, C
2001-09-01
The authors present the results of a retrospective national enquiry which took place in 1999 and was mailed and faxed to the 3,800 cardiologists practising in the private sector in order to assess the different types of continuous, individual and collective postgraduate training which they had benefited from in the preceding 12 months. The data was analysed by comparison with that obtained from an individualized representative sample in a panel of private sector cardiologists. The results were then compared with the criteria of a yardstick proposed by the National Committee of Continuous Medical Education of 1997, according to the April 25th 1996 decree. The meeting of these criteria would require carrying out 114,000 to 76,000 hour-equivalents of continuous education whereas the present offer is about 100,000 hour-equivalents. The different forms of individual or collective training were compared in the 327 questionnaires which were exploitable following adhesion to the French Society of Cardiology, to the Cardiologists' Union, to local cardiological societies, by age, gender and type of practice. The average number of annual hours of collective education was 52.2 +/- 60.1 hours (25% quartile = 25 hours, 75% = 60 hours). The average value of hours of individual education was 89.7 +/- 89.3 hours (25% quartile = 25 hours; 75% = 120 hours). This evaluation indicates that about 15% of cardiologists practising in the private sector have inadequate continuous medical education and that 68% would satisfy the criteria laid down in 1997. Moreover, the present offer would seem to be adequate providing the criteria of accreditation have been met.
10 CFR 170.20 - Average cost per professional staff-hour.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 2 2013-01-01 2013-01-01 false Average cost per professional staff-hour. 170.20 Section... Provisions § 170.20 Average cost per professional staff-hour. Fees for permits, licenses, amendments... professional staff-hour rate of $274 per hour. [77 FR 35826, June 15, 2012] Schedule of Fees ...
10 CFR 170.20 - Average cost per professional staff-hour.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 2 2010-01-01 2010-01-01 false Average cost per professional staff-hour. 170.20 Section... Provisions § 170.20 Average cost per professional staff-hour. Fees for permits, licenses, amendments... professional staff-hour rate of $257 per hour. [74 FR 27660, June 10, 2009] Schedule of Fees ...
10 CFR 170.20 - Average cost per professional staff-hour.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 2 2014-01-01 2014-01-01 false Average cost per professional staff-hour. 170.20 Section... Provisions § 170.20 Average cost per professional staff-hour. Fees for permits, licenses, amendments... professional staff-hour rate of $272 per hour. [78 FR 39481, July 1, 2013] Schedule of Fees ...
10 CFR 170.20 - Average cost per professional staff-hour.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 2 2011-01-01 2011-01-01 false Average cost per professional staff-hour. 170.20 Section... Provisions § 170.20 Average cost per professional staff-hour. Fees for permits, licenses, amendments... professional staff-hour rate of $259 per hour. [75 FR 34235, June 16, 2010] Schedule of Fees ...
Sizing procedures for sun-tracking PV system with batteries
NASA Astrophysics Data System (ADS)
Nezih Gerek, Ömer; Başaran Filik, Ümmühan; Filik, Tansu
2017-11-01
Deciding optimum number of PV panels, wind turbines and batteries (i.e. a complete renewable energy system) for minimum cost and complete energy balance is a challenging and interesting problem. In the literature, some rough data models or limited recorded data together with low resolution hourly averaged meteorological values are used to test the sizing strategies. In this study, active sun tracking and fixed PV solar power generation values of ready-to-serve commercial products are recorded throughout 2015-2016. Simultaneously several outdoor parameters (solar radiation, temperature, humidity, wind speed/direction, pressure) are recorded with high resolution. The hourly energy consumption values of a standard 4-person household, which is constructed in our campus in Eskisehir, Turkey, are also recorded for the same period. During sizing, novel parametric random process models for wind speed, temperature, solar radiation, energy demand and electricity generation curves are achieved and it is observed that these models provide sizing results with lower LLP through Monte Carlo experiments that consider average and minimum performance cases. Furthermore, another novel cost optimization strategy is adopted to show that solar tracking PV panels provide lower costs by enabling reduced number of installed batteries. Results are verified over real recorded data.
Methodology for adding glycemic index and glycemic load values to 24-hour dietary recall database.
Olendzki, Barbara C; Ma, Yunsheng; Culver, Annie L; Ockene, Ira S; Griffith, Jennifer A; Hafner, Andrea R; Hebert, James R
2006-01-01
We describe a method of adding the glycemic index (GI) and glycemic load (GL) values to the nutrient database of the 24-hour dietary recall interview (24HR), a widely used dietary assessment. We also calculated daily GI and GL values from the 24HR. Subjects were 641 healthy adults from central Massachusetts who completed 9067 24HRs. The 24HR-derived food data were matched to the International Table of Glycemic Index and Glycemic Load Values. The GI values for specific foods not in the table were estimated against similar foods according to physical and chemical factors that determine GI. Mixed foods were disaggregated into individual ingredients. Of 1261 carbohydrate-containing foods in the database, GI values of 602 foods were obtained from a direct match (47.7%), accounting for 22.36% of dietary carbohydrate. GI values from 656 foods (52.1%) were estimated, contributing to 77.64% of dietary carbohydrate. The GI values from three unknown foods (0.2%) could not be assigned. The average daily GI was 84 (SD 5.1, white bread as referent) and the average GL was 196 (SD 63). Using this methodology for adding GI and GL values to nutrient databases, it is possible to assess associations between GI and/or GL and body weight and chronic disease outcomes (diabetes, cancer, heart disease). This method can be used in clinical and survey research settings where 24HRs are a practical means for assessing diet. The implications for using this methodology compel a broader evaluation of diet with disease outcomes.
Depletion of tropospheric ozone associated with mineral dust outbreaks.
Soler, Ruben; Nicolás, J F; Caballero, S; Yubero, E; Crespo, J
2016-10-01
From May to September 2012, ozone reductions associated with 15 Saharan dust outbreaks which occurred between May to September 2012 have been evaluated. The campaign was performed at a mountain station located near the eastern coast of the Iberian Peninsula. The study has two main goals: firstly, to analyze the decreasing gradient of ozone concentration during the course of the Saharan episodes. These gradients vary from 0.2 to 0.6 ppb h(-1) with an average value of 0.39 ppb h(-1). The negative correlation between ozone and coarse particles occurs almost simultaneously. Moreover, although the concentration of coarse particles remained high throughout the episode, the time series shows the saturation of the ozone loss. The highest ozone depletion has been obtained during the last hours of the day, from 18:00 to 23:00 UTC. Outbreaks registered during this campaign have been more intense in this time slot. The second objective is to establish from which coarse particle concentration a significant ozone depletion can be observed and to quantify this reduction. In this regard, it has been confirmed that when the hourly particle concentration recorded during the Saharan dust outbreaks is above the hourly particle median values (N > N-median), the ozone concentration reduction obtained is statistically significant. An average ozone reduction of 5.5 % during Saharan events has been recorded. In certain cases, this percentage can reach values of higher than 15 %.
NASA Astrophysics Data System (ADS)
Falkensammer, Peter; Soegner, Peter I.; zur Nedden, Dieter
2002-05-01
The integration of RIS-PACS systems in radiology units are intended to reduce time consumption in radiology workflow and thus to increase radiologist productivity. Along with the RIS-PACS integration at the University Hospital Innsbruck we analyzed workflow from patient admission to release of final reports before implementation. The follow up study after six months of the implementation is currently in work. In this study we compared chest to skeletal x-ray examinations in 969 patients before the implementation. Drawing the admission-to-release-of-final-report period showed a two-peak diagram with the first peak corresponding to a release of final results on the same day and the second peak to a release on the following day. In the chest x-ray group, 57% were released the same day (mean value 4:02 hours) and 43% the next day (mean value 21:47 hours). Looking at the skeletal x-rays 40% were released the same day (mean value 3:58 hours) and 60% were released the next day (mean value 21:05 hours). Summarizing the results we should say, that the average chest x-ray requires less time than an skeletal x-ray, due to the fact that a greater percentage of reports is released the same day. The most important result is, that the most time consuming workstep is the exchange of data media between radiologist and secretary with at least 5 hours.
CURRENT FLOW DATA FOR SELECTED USGS STREAM MONITORING STATIONS
This data set contains recent and historical stream flow data for USGS stations. Flow data (cubic feet per second) are available for the most recent 5-6 day period and are compared with long-term average values. Flow data were collected approximately hourly. Flood stage and the m...
CURRENT FLOW DATA FOR SELECTED USGS STREAM MONITORING STATIONS IN WASHINGTON STATE
This data set contains recent stream flow data for USGS stations in Washington State. Flow data (cubic feet per second) are available for the most recent 5-6 day period and are compared with long-term average values. Flow data were collected approximately hourly. Flood stage and ...
Selected meteorological data for an arid site near Beatty, Nye County, Nevada, calendar year 1987
Wood, James L.; Fischer, Jeffrey M.
1992-01-01
Selected meteorological data were collected at a study site adjacent to a low-level radioactive-waste burial facility near Beatty, Nevada, for calendar year 1987. Data were collected in support of an ongoing study to estimate the potential for downward movement of radionuclides into the unsaturated sediments beneath waste-burial trenches at the facility. The data include air temperature, relative humidity, vapor pressure, incident solar radiation, windspeed, wind direction, and precipitation. The data are summarized in tables and graphs A discussion of the instrumentation used at the site is presented. Included in the discussion are the type of sensors, their reported accuracy, and mounting height of each sensor.In 1987, the average hourly air temperatures ranged from -7.6 degrees Celsius, in December, to 43.1 degrees Celsius, in July. Hourly averaged relative humidity ranged from about 12 percent to over 80 percent. Hourly vapor pressures ranged from 0.12 to 1.77 kilopascals. Daily values for maximum incident solar radiation ranged from 118 to 1,067 watts per square meter. Daily mean windspeed ranged from 1.4 to 9.4 meters per second. Monthly wind-direction patterns are shown in a series of diagrams in which wind direction is summed over 10-degree arcs from hourly averaged data. Total precipitation for 1987 was 136.4 millimeters, more than 75 percent occurring during January-April and November-December.
NASA Astrophysics Data System (ADS)
Firk, Frank W. K.
2014-03-01
It is shown that the R-matrix theory of nuclear reactions is a viable mathematical theory for the description of the fine, intermediate and gross structure observed in the time-dependence of economic indices in general, and the daily Dow Jones Industrial Average in particular. A Lorentzian approximation to R-matrix theory is used to analyze the complex structures observed in the Dow Jones Industrial Average on a typical trading day. Resonant structures in excited nuclei are characterized by the values of their fundamental strength function, (average total width of the states)/(average spacing between adjacent states). Here, values of the ratios (average lifetime of individual states of a given component of the daily Dow Jones Industrial Average)/(average interval between the adjacent states) are determined. The ratios for the observed fine and intermediate structure of the index are found to be essentially constant throughout the trading day. These quantitative findings are characteristic of the highly statistical nature of many-body, strongly interacting systems, typified by daily trading. It is therefore proposed that the values of these ratios, determined in the first hour-or-so of trading, be used to provide valuable information concerning the likely performance of the fine and intermediate components of the index for the remainder of the trading day.
de Queiroz, João Paulo Araújo Fernandes; de Souza, João Batista Freire; de Lima, Hiagos Felipe Ferreira; de Oliveira Costa, Monik Kelly; de Macedo Costa, Leonardo Lelis; de Arruda, Alex Martins Varela
2014-08-01
The aim of this study was to evaluate the daily variations in the thermoregulatory behavior of 4- to 6-week-old naked neck broilers (Label Rouge) in an equatorial semi-arid environment. A total of 220 birds were monitored for 5 days starting at 0600 hours and ending at 1800 hours. The period of observation was divided into classes of hours (C H). The observed behaviors were as follows: feed and water intake, wing-spreading, sitting or lying, and beak-opening. A total of 14,300 behavioral data values were registered. In C H 2 (0900 hours to 1100 hours) and 3 (1200 hours to 1500 hours), the greatest average body surface temperature was recorded (34.67 ± 0.25 °C and 35.12 ± 0.22 °C, respectively). The C H had an effect on the exhibition of all behaviors with the exception of the water intake behavior. Feed intake was more frequent in C H 1 (0600 hours to 0800 hours) and 4 (1600 hours to 1800 hours). In C H 2 and 3, the highest frequency of sitting or lying behavior was observed. Beak-opening and wing-spreading behaviors occurred more frequently in C H 3 where the body surface temperature (35.12 ± 0.22 °C), radiant heat load (519.38 ± 2.22 W m(-2)), and enthalpy (82.74 ± 0.36 kJ kg(-1) of dry air) reached maximum recorded averages. Thus, it can be concluded that naked neck broilers adjust their behavior in response to daily variations in the thermal environment. Wing-spreading and beak-opening behaviors are important adaptive responses to the thermal challenges posed by the equatorial semi-arid environment.
Vagedes, Jan; Bialkowski, Anja; Wiechers, Cornelia; Poets, Christian F.; Dietz, Klaus
2014-01-01
Objective The number of desaturations determined in recordings of pulse oximeter saturation (SpO2) primarily depends on the time over which values are averaged. As the averaging time in pulse oximeters is not standardized, it varies considerably between centers. To make SpO2 data comparable, it is thus desirable to have a formula that allows conversion between desaturation rates obtained using different averaging times for various desaturation levels and minimal durations. Methods Oxygen saturation was measured for 170 hours in 12 preterm infants with a mean number of 65 desaturations <90% per hour of arbitrary duration by using a pulse oximeter in a 2–4 s averaging mode. Using 7 different averaging times between 3 and 16 seconds, the raw red-to-infrared data were reprocessed to determine the number of desaturations (D). The whole procedure was carried out for 7 different minimal desaturation durations (≥1, ≥5, ≥10, ≥15, ≥20, ≥25, ≥30 s) below SpO2 threshold values of 80%, 85% or 90% to finally reach a conversion formula. The formula was validated by splitting the infants into two groups of six children each and using one group each as a training set and the other one as a test set. Results Based on the linear relationship found between the logarithm of the desaturation rate and the logarithm of the averaging time, the conversion formula is: D2 = D1 (T2/T1)c, where D2 is the desaturation rate for the desired averaging time T2, and D1 is the desaturation rate for the original averaging time T1, with the exponent c depending on the desaturation threshold and the minimal desaturation duration. The median error when applying this formula was 2.6%. Conclusion This formula enables the conversion of desaturation rates between different averaging times for various desaturation thresholds and minimal desaturation durations. PMID:24489887
Vagedes, Jan; Bialkowski, Anja; Wiechers, Cornelia; Poets, Christian F; Dietz, Klaus
2014-01-01
The number of desaturations determined in recordings of pulse oximeter saturation (SpO2) primarily depends on the time over which values are averaged. As the averaging time in pulse oximeters is not standardized, it varies considerably between centers. To make SpO2 data comparable, it is thus desirable to have a formula that allows conversion between desaturation rates obtained using different averaging times for various desaturation levels and minimal durations. Oxygen saturation was measured for 170 hours in 12 preterm infants with a mean number of 65 desaturations <90% per hour of arbitrary duration by using a pulse oximeter in a 2-4 s averaging mode. Using 7 different averaging times between 3 and 16 seconds, the raw red-to-infrared data were reprocessed to determine the number of desaturations (D). The whole procedure was carried out for 7 different minimal desaturation durations (≥ 1, ≥ 5, ≥ 10, ≥ 15, ≥ 20, ≥ 25, ≥ 30 s) below SpO2 threshold values of 80%, 85% or 90% to finally reach a conversion formula. The formula was validated by splitting the infants into two groups of six children each and using one group each as a training set and the other one as a test set. Based on the linear relationship found between the logarithm of the desaturation rate and the logarithm of the averaging time, the conversion formula is: D2 = D1 (T2/T1)(c), where D2 is the desaturation rate for the desired averaging time T2, and D1 is the desaturation rate for the original averaging time T1, with the exponent c depending on the desaturation threshold and the minimal desaturation duration. The median error when applying this formula was 2.6%. This formula enables the conversion of desaturation rates between different averaging times for various desaturation thresholds and minimal desaturation durations.
Forecasting air quality time series using deep learning.
Freeman, Brian S; Taylor, Graham; Gharabaghi, Bahram; Thé, Jesse
2018-04-13
This paper presents one of the first applications of deep learning (DL) techniques to predict air pollution time series. Air quality management relies extensively on time series data captured at air monitoring stations as the basis of identifying population exposure to airborne pollutants and determining compliance with local ambient air standards. In this paper, 8 hr averaged surface ozone (O 3 ) concentrations were predicted using deep learning consisting of a recurrent neural network (RNN) with long short-term memory (LSTM). Hourly air quality and meteorological data were used to train and forecast values up to 72 hours with low error rates. The LSTM was able to forecast the duration of continuous O 3 exceedances as well. Prior to training the network, the dataset was reviewed for missing data and outliers. Missing data were imputed using a novel technique that averaged gaps less than eight time steps with incremental steps based on first-order differences of neighboring time periods. Data were then used to train decision trees to evaluate input feature importance over different time prediction horizons. The number of features used to train the LSTM model was reduced from 25 features to 5 features, resulting in improved accuracy as measured by Mean Absolute Error (MAE). Parameter sensitivity analysis identified look-back nodes associated with the RNN proved to be a significant source of error if not aligned with the prediction horizon. Overall, MAE's less than 2 were calculated for predictions out to 72 hours. Novel deep learning techniques were used to train an 8-hour averaged ozone forecast model. Missing data and outliers within the captured data set were replaced using a new imputation method that generated calculated values closer to the expected value based on the time and season. Decision trees were used to identify input variables with the greatest importance. The methods presented in this paper allow air managers to forecast long range air pollution concentration while only monitoring key parameters and without transforming the data set in its entirety, thus allowing real time inputs and continuous prediction.
ESTIMATING SYSTEMIC EXPOSURE TO ETHINYL ESTRADIOL FROM AN ORAL CONTRACEPTIVE
WESTHOFF, Carolyn L.; PIKE, Malcolm C.; TANG, Rosalind; DINAPOLI, Marianne N.; SULL, Monica; CREMERS, Serge
2015-01-01
Objectives This study was conducted to compare single-dose pharmacokinetics of ethinyl estradiol in an oral contraceptive to steady-state values, and to assess whether any simpler measures could provide an adequate proxy of the ‘gold standard’ 24-hour steady-state area-under-the-curve. Identifying a simple, less expensive, measure of systemic ethinyl estradiol exposure would be useful for larger studies designed to assess the relationship between an individual’s ethinyl estradiol exposure and her side effects. Study Design We conducted a 13 samples over 24 hours pharmacokinetic analysis on day 1 and day 21 of the first cycle of a monophasic oral contraceptive containing 30 mcg ethinyl estradiol and 150 mcg levonorgestrel in 17 non-obese healthy white women. We also conducted an abbreviated single dose 9-sample pharmacokinetic analysis after a month washout. Ethinyl estradiol was measured by liquid chromatography-tandem mass spectrometry. We compared results of full 13-sample steady-state pharmacokinetic analysis with results calculated using fewer samples (9 or 5) and following the single doses. We calculated Pearson correlation coefficients to evaluate the relationships between these estimates of systemic ethinyl estradiol exposure. Results The area-under-the-curve, maximum (Cmax), and 24-hour (C24) values were similar following the two single oral contraceptive doses (area-under-the-curve, r = 0.92). The steady-state 13-sample 24-hour area-under-the-curve was highly correlated with the average 9-sample area-under-the-curve after the two single doses (r = 0.81, p = 0.0002). This correlation remained the same if the number of samples was reduced to 4, taken at time 1, 2.5, 4 and 24 hours. The C24 at steady-state was highly correlated with the 24-hour steady-state area-under-the-curve (r = 0.92, p < 0.0001). The average of the C24 values following the two single doses was also quite highly correlated with the steady-state area-under-the-curve (r = 0.72, p = 0.0026). Conclusions Limited blood sampling, including results from two single doses, gave highly correlated estimates of an oral contraceptive user’s steady-state ethinyl estradiol exposure. PMID:25511238
de Paula Xavier de Andrade, Rafael; de Andrade Ferreira, Marcelo; de Azevedo, Marcílio; da Silva, Emmanuelle Cordeiro; Urbano, Stela Antas; da Conceição, Maria Gabriela; de Lima Silva, Janaina
2017-01-01
The effects of time of feed delivery (14.00 hours; 14.00 and 20.00 hours; 16.00 and 18.00 hours) on the physiological parameters, ingestive behavior, nutrient intake and production of lactating cows maintained in a semi-arid region during the hot season were evaluated. Regardless of treatment, all animals received the first feeding supply at 06.00 hours. Eight cows with an average body weight of 600 kg, average milk yield of 20 kg/day and 80 days in milk were utilized. The rectal temperature, respiratory rate and sweating rate were not affected (P > 0.05), with average values of 38.5°C, 53.8 movements/min and 104 g/m 2 /h respectively. There was no effect (P > 0.05) on the eating time (314 min/day), ruminating time (564 min/day), drinking time (61 min/day) and idle time (502 min/day). Similarly, the intake of nutrients and performance of lactating cows were not affected (P > 0.05), with average dry matter intake of 19.8 kg/day, 4% fat-corrected milk of 20.6 kg/day and milk fat concentration of 4.03 g/100 g. Since the behavior and performance have not altered, any times of feed delivery evaluated could be used to crossbred Holstein × Zebu cows maintained on a feedlot in semi-arid regions during the hot season. © 2016 Japanese Society of Animal Science.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Use Equation 2 in § 60.2975 to calculate the 12-hour rolling averages for concentrations of carbon... averages into the appropriate averaging times and units? 60.2943 Section 60.2943 Protection of Environment... 16, 2006 Monitoring § 60.2943 How do I convert my 1-hour arithmetic averages into the appropriate...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Use Equation 2 in § 60.2975 to calculate the 12-hour rolling averages for concentrations of carbon... averages into the appropriate averaging times and units? 60.2943 Section 60.2943 Protection of Environment... 16, 2006 Monitoring § 60.2943 How do I convert my 1-hour arithmetic averages into the appropriate...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-01-01
Data were collected at the Shelly Ridge Girl Scout Center using an Aeolian Kinetics PDL-24 data acquisition system. Instantaneous data readings were recorded each 15 seconds by the microprocessor. These channel readings were then averaged to produce hourly values which were then stored on an audio cassette. These hourly data were then transcribed to the AIAF archive. The Girl Scout Center features an 861 square foot unvented Trombe wall, a direct gain sunspace, and two rooftop collectors for heating domestic water.
1979-05-01
fallout patterns by "dot-dash" lines. The time lines are intended to give only a rough average arrival time in hours as estimated from the wind reports and...by interpolation between the H-lI and H+11 hour values. 4. The surface air pressure was 13.10 psi, the temperature -2.O°C and the relative humidity...surface air pressure was 13.04 psi, the temperature -2.8 0 C, and the relative humidity 87%. 17 i’ 17 I
Semple, S; Garden, C; Coggins, M; Galea, KS; Whelan, P; Cowie, H; Sánchez-Jimenéz, A; Thorne, PS; Hurley, JF; Ayres, JG
2012-01-01
There are limited data describing pollutant levels inside homes that burn solid fuel within developed country settings with most studies describing test conditions or the effect of interventions. This study recruited homes in Ireland and Scotland where open combustion processes take place. Open combustion was classified as coal, peat or wood fuel burning, use of a gas cooker or stove, or where there is at least one resident smoker. 24-hour data on airborne concentrations of particulate matter less than 2.5 microns in size (PM2.5), carbon monoxide (CO), endotoxin in inhalable dust and carbon dioxide (CO2), together with 2–3 week averaged concentrations of nitrogen dioxide (NO2) were collected in 100 houses during the winter and spring of 2009–2010. The geometric mean of the 24-hour time-weighted-average (TWA) PM2.5 concentration was highest in homes with resident smokers (99μg/m3 – much higher than the WHO 24-hour guidance value of 25 μg/m3. Lower geometric mean 24-hour TWA levels were found in homes that burned coal (7 μg/m3) or wood (6 μg/m3) and in homes with gas cookers (7 μg/m3). In peat-burning homes the average 24-hourPM2.5 level recorded was 11 μg/m3. Airborne endotoxin, CO, CO2 and NO2 concentrations were generally within indoor air quality guidance levels. PMID:22007695
NASA Astrophysics Data System (ADS)
Lee, Bing-Sun; Chiou, Chung-Biau; Lin, Chung-Yi
2014-12-01
Hourly atmospheric measurements of halocarbons and chlorofluorocarbon (CFC) replacements were conducted at an urban site of Lukang, Changhua, in central Taiwan from May to August, 2013. The temporal distribution of different groups of halocarbons in the Lukang urban atmosphere, including chlorofluorocarbons (CFCs), Chlorodifluoromethane (HCFC-22), Bromochlorodifluoromethane (Halon-1211), and other chlorinated compounds, is presented and discussed. The concentrations (mixing ratios) of HCFC-22, Dichlorodifluoromethane (CFC-12), Halon-1211, Trichlorofluoromethane (CFC-11), Dichloromethane (CH2Cl2), and Trichloroethylene (TCE) were enhanced with respect to the local background levels; the atmospheric mixing ratio of carbon tetrachloride (CCl4) was slightly higher than its local background level; on the other hand, 1,1,2-Trichlorotrifluoroethane (CFC-113) was relatively uniform and not very different from background atmospheric level in non-urban areas. Among these compounds, HCFC-22, Halon-1211 and the halogenated compounds, CH2Cl2 and TCE, used as solvents were strongly enhanced. The average mixing ratio of Halon-1211 was higher than the local background of ∼4.5 ppt by ∼60% although Halon-1211 production had been phased out by 1996. Hourly average mixing ratios of halocarbons (HCFC-22, CFC-12, Halon-1211, CFC-11, CH2Cl2, and TCE) illustrated a distinct diurnal cycle characterized with a pattern of elevated mixing ratio and large mixing ratio variability amplitude at night relative to that in daytime. Although emission sources of these halocarbons were complex, hourly average mixing ratios for most of these high variability halocarbons peaked at ∼5:00 AM when the hourly average wind speed reached the minimum value of the day; by contrast, the hourly average mixing ratio of CO peaked at ∼8:30 AM when the ambient atmospheric wind condition was strongly influenced by sea breezes during the traffic rush hours. This phenomenon revealed that meteorological factors predominated the distribution of halocarbon mixing ratio in the urban atmosphere and the traffic emission of CFC-12 derived from old vehicles manufactured before 1994 was insignificant to the CFC-12 mixing ratio in the urban atmosphere. The meteorological condition of nighttime atmospheric temperature inversion and low wind speed facilitated the accumulation of terrestrial airborne pollutants near the ground; consequently the hourly average mixing ratios at night were higher than those in daytime by up to ∼2% (CFC-11), ∼7% (CFC-12), ∼75% (HCFC-22), ∼72% (Halon-1211), ∼280% (CH2Cl2), and ∼155% (TCE).
40 CFR 63.11567 - Who implements and enforces this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... enforces this subpart? (a) This subpart can be implemented and enforced by us, the U.S. Environmental... * * * And maintain a * * * 1. A thermal oxidizer Combustion zone temperature The 3-hour average combustion zone temperature at or above the operating value established as specified in § 63.11562(a)(2) and (b)(2...
40 CFR 63.11567 - Who implements and enforces this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... enforces this subpart? (a) This subpart can be implemented and enforced by us, the U.S. Environmental... * * * And maintain a * * * 1. A thermal oxidizer Combustion zone temperature The 3-hour average combustion zone temperature at or above the operating value established as specified in § 63.11562(a)(2) and (b)(2...
40 CFR 63.11567 - Who implements and enforces this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... enforces this subpart? (a) This subpart can be implemented and enforced by us, the U.S. Environmental... * * * And maintain a * * * 1. A thermal oxidizer Combustion zone temperature The 3-hour average combustion zone temperature at or above the operating value established as specified in § 63.11562(a)(2) and (b)(2...
40 CFR Table 4 to Subpart Kkkkk of... - Requirements for Performance Tests
Code of Federal Regulations, 2010 CFR
2010-07-01
... block average pressure drop values for the three test runs, and determine and record the 3-hour block... limit for the limestone feeder setting Data from the limestone feeder during the performance test You must ensure that you maintain an adequate amount of limestone in the limestone hopper, storage bin...
Mass Media Values and the Future of Education.
ERIC Educational Resources Information Center
Pulliam, John D.
The paper focuses on the impact of mass media, especially television, on the educational process and outlines implications for the future. Studies point out that children view an average of 8,000 hours of television annually between ages three and five. Positive effects include increase in the vocabulary of young children, a better appreciation of…
Association Between Sleep and Productivity Loss Among 598 676 Employees From Multiple Industries.
Gingerich, Stefan B; Seaverson, Erin L D; Anderson, David R
2018-05-01
To examine the relationship between sleep habits and employee productivity. Cross-sectional health risk assessment analysis. Employer-sponsored health and well-being programs. A total of 598 676 employed adults from multiple industries. Self-reported average hours of sleep, fatigue, absence days, and presenteeism. Bivariate analyses to assess the relationships between self-reported hours of sleep and self-reported fatigue and mean and median absence and presenteeism. The relationship between sleep hours and both measures of productivity was U-shaped, with the least productivity loss among employees who reported 8 hours of sleep. More daytime fatigue correlated with more absence and presenteeism. Median absence and presenteeism was consistently lower than mean absence and presenteeism, respectively, for the various hours of sleep and levels of fatigue. Organizations looking to expand the value of their investment in employee health and well-being should consider addressing the employee sleep habits that may be negatively impacting productivity.
NASA Astrophysics Data System (ADS)
Sheng, Jie; Zhu, Qiaoming; Cao, Shijie; You, Yang
2017-05-01
This paper helps in study of the relationship between the photovoltaic power generation of large scale “fishing and PV complementary” grid-tied photovoltaic system and meteorological parameters, with multi-time scale power data from the photovoltaic power station and meteorological data over the same period of a whole year. The result indicates that, the PV power generation has the most significant correlation with global solar irradiation, followed by diurnal temperature range, sunshine hours, daily maximum temperature and daily average temperature. In different months, the maximum monthly average power generation appears in August, which related to the more global solar irradiation and longer sunshine hours in this month. However, the maximum daily average power generation appears in October, this is due to the drop in temperature brings about the improvement of the efficiency of PV panels. Through the contrast of monthly average performance ratio (PR) and monthly average temperature, it is shown that, the larger values of monthly average PR appears in April and October, while it is smaller in summer with higher temperature. The results concluded that temperature has a great influence on the performance ratio of large scale grid-tied PV power system, and it is important to adopt effective measures to decrease the temperature of PV plant properly.
Villa, A; Cabezas, L; Anabalón, M; Rugg-Gunn, A
2009-09-01
To assess whether there was any significant difference in the average fractional urinary fluoride excretion (FUFE) values among adults consuming (NaF) fluoridated Ca-free water (reference water), naturally fluoridated hard water and an artificially (H2SiF6) fluoridated soft water. Sixty adult females (N=20 for each treatment) participated in this randomized, double-blind trial. The experimental design of this study provided an indirect estimation of the fluoride absorption in different types of water through the assessment of the fractional urinary fluoride excretion of volunteers. Average daily FUFE values (daily amount of fluoride excreted in urine/daily total fluoride intake) were not significantly different between the three treatments (Kruskal-Wallis; p = 0.62). The average 24-hour FUFE value (n=60) was 0.69; 95% C.I. 0.65-0.73. The results of this study suggest that the absorption of fluoride is not affected by water hardness.
Intracellular delivery and trafficking dynamics of a lymphoma-targeting antibody-polymer conjugate
Berguig, Geoffrey Y.; Convertine, Anthony J.; Shi, Julie; Palanca-Wessels, Maria Corinna; Duvall, Craig L.; Pun, Suzie H.; Press, Oliver W.; Stayton, Patrick S.
2012-01-01
Ratiometric fluorescence and cellular fractionation studies were employed to characterize the intracellular trafficking dynamics of antibody-poly(propylacrylic acid) (PPAA) conjugates in CD22+ RAMOS-AW cells. The HD39 monoclonal antibody (mAb) directs CD22-dependent, receptor-mediated uptake in human B-cell lymphoma cells where it is rapidly trafficked to the lysosomal compartment. To characterize the intracellular-releasing dynamics of the polymer-mAb conjugates, HD39-streptavidin (HD39/SA) was dual-labeled with pH-insensitive Alex Fluor 488 and pH-sensitive pHrodo fluorophores. The subcellular pH-distribution of the HD39/SA-polymer conjugates were quantified as a function of time by live-cell fluorescence microscopy, and the average intracellular pH values experienced by the conjugates were also characterized as a function of time by flow cytometry. PPAA was shown to strongly alter the intracellular trafficking kinetics compared to HD39/SA alone or HD39/SA conjugates with a control polymer, poly(methacryclic acid) (PMAA). Subcellular trafficking studies revealed that after 6 hours only 11% of the HD39/SA-PPAA conjugates had been trafficked to acidic lysosomal compartments with values at or below pH 5.6. In contrast the average intracellular pH of HD39/SA alone dropped from pH 6.7 ± 0.2 at 1 hour to pH 5.6 ± 0.5 after 3 hours and pH 4.7 ± 0.6 after 6 hours. Conjugation of the control PMAA to HD39/SA showed an average pH drop similar to HD39/SA. Subcellular fractionation studies with tritium-labeled HD39/SA demonstrated that after 6 hours, 89% of HD39/SA was associated with endosomes (Rab5+) and lysosomes (Lamp2+), while 45% of HD39/SA-PPAA was translocated to the cytosol (lactate dehydrogenase+). These results demonstrate the endosomal-releasing properties of PPAA with antibody-polymer conjugates and detail their intracellular trafficking dynamics and subcellular compartmental distributions over time. PMID:23075320
40 CFR 49.137 - Rule for air pollution episodes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... continue or reoccur over the next 24 hours. (A) Particulate matter (PM10): 350 micrograms per cubic meter, 24-hour average; (B) Carbon monoxide (CO): 17 milligrams per cubic meter (15 ppm), 8-hour average; (C) Sulfur dioxide (SO2): 800 micrograms per cubic meter (0.3 ppm), 24-hour average; (D) Ozone (O3): 400...
Pérez, M C; Álvarez-Hornos, F J; Engesser, K H; Dobslaw, D; Gabaldón, C
2016-03-25
The removal of 2-butoxyethanol from gaseous emissions was studied using two biotrickling filters (BTF1 and BTF2) packed with polyurethane foam. Two different inoculum sources were used: a pure culture of Pseudomonas sp. BOE200 (BTF1) and activated sludge from a municipal wastewater treatment plant (BTF2). The bioreactors were operated at inlet loads (ILs) of 130 and 195 g m(-3) hour(-1) and at an empty bed residence time (EBRT) of 12.5s. Under an IL of ∼130 g m(-3) hour(-1), BTF1 presented higher elimination capacities (ECs) than BTF2, with average values of 106±7 and 68±8 g m(-3) hour(-1), respectively. However, differences in ECs between BTFs were decreased by reducing the irrigation intervals from 1 min every 12 min to 1 min every 2 hours in BTF2. Average values of EC were 111±25 and 90±7 g m(-3) hour(-1) for BTF1 and BTF2, respectively, when working at an IL of ∼195 g m(-3) hour(-1). Microbial analysis revealed a significant shift in the microbial community of BTF1 inoculated with Pseudomonas sp. BOE200. At the end of the experiment, the species Microbacterium sp., Chryseobacterium sp., Acinetobacter sp., Pseudomonas sp. and Mycobacterium sp. were detected. In BTF2 inoculated with activated sludge, the denaturing gradient gel electrophoresis (DGGE) technique showed a diverse microbial community including species that was able to use 2-butoxyethanol as its carbon source, such as Pseudomonas aeruginosa and Pseudomonas putida as representative species. Although BTF1 inoculated with Pseudomonas sp. BOE200 and higher gas velocity (probably greater gas/liquid mass transfer rate) showed a slight improvement in performance, the use of activated sludge as inoculum seems to be a more feasible option for the industrial application of this technology. Copyright © 2015 Elsevier B.V. All rights reserved.
Which metric of ambient ozone to predict daily mortality?
NASA Astrophysics Data System (ADS)
Moshammer, Hanns; Hutter, Hans-Peter; Kundi, Michael
2013-02-01
It is well known that ozone concentration is associated with daily cause specific mortality. But which ozone metric is the best predictor of the daily variability in mortality? We performed a time series analysis on daily deaths (all causes, respiratory and cardiovascular causes as well as death in elderly 65+) in Vienna for the years 1991-2009. We controlled for seasonal and long term trend, day of the week, temperature and humidity using the same basic model for all pollutant metrics. We found model fit was best for same day variability of ozone concentration (calculated as the difference between daily hourly maximum and minimum) and hourly maximum. Of these the variability displayed a more linear dose-response function. Maximum 8 h moving average and daily mean value performed not so well. Nitrogen dioxide (daily mean) in comparison performed better when previous day values were assessed. Same day ozone and previous day nitrogen dioxide effect estimates did not confound each other. Variability in daily ozone levels or peak ozone levels seem to be a better proxy of a complex reactive secondary pollutant mixture than daily average ozone levels in the Middle European setting. If this finding is confirmed this would have implications for the setting of legally binding limit values.
40 CFR Table 2 to Subpart Jjjjj of... - Operating Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Kiln equipped with a WS a. Maintain the average scrubber pressure drop for each 3-hour block period at... average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test; and c. Maintain the average scrubber liquid flow rate for each 3-hour...
40 CFR Table 2 to Subpart Jjjjj of... - Operating Limits
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Kiln equipped with a WS a. Maintain the average scrubber pressure drop for each 3-hour block period at... average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test; and c. Maintain the average scrubber liquid flow rate for each 3-hour...
NASA Astrophysics Data System (ADS)
Drew, G. H.; Smith, R.; Gerard, V.; Burge, C.; Lowe, M.; Kinnersley, R.; Sneath, R.; Longhurst, P. J.
Odour emissions are episodic, characterised by periods of high emission rates, interspersed with periods of low emissions. It is frequently the short term, high concentration peaks that result in annoyance in the surrounding population. Dispersion modelling is accepted as a useful tool for odour impact assessment, and two approaches can be adopted. The first approach of modelling the hourly average concentration can underestimate total odour concentration peaks, resulting in annoyance and complaints. The second modelling approach involves the use of short averaging times. This study assesses the appropriateness of using different averaging times to model the dispersion of odour from a landfill site. We also examine perception of odour in the community in conjunction with the modelled odour dispersal, by using community monitors to record incidents of odour. The results show that with the shorter averaging times, the modelled pattern of dispersal reflects the pattern of observed odour incidents recorded in the community monitoring database, with the modelled odour dispersing further in a north easterly direction. Therefore, the current regulatory method of dispersion modelling, using hourly averaging times, is less successful at capturing peak concentrations, and does not capture the pattern of odour emission as indicated by the community monitoring database. The use of short averaging times is therefore of greater value in predicting the likely nuisance impact of an odour source and in framing appropriate regulatory controls.
Selected meteorological data for an arid site near Beatty, Nye County, Nevada, calendar year 1989
Wood, J.L.; Andraski, Brian J.
1992-01-01
Selected meteorological data were collected at a study site adjacent to a low-level radioactive-waste burial facility near Beatty, Nevada, for calendar year 1989. Data were collected in support of ongoing studies to estimate the potential for downward movement of radionuclides into the unsaturated sediments beneath waste-burial trenches at the facility. The data include air temperature, relative humidity, vapor pressure, incident solar radiation, windspeed, wind direction, and precipitation. The data are summarized in tables and graphs.Instrumentation used at the site is discussed. The discussion includes the type, reported accuracy, and mounting height of each sensor.In 1989, the hourly averaged air temperature ranged from -14.5 degrees Celsius, in February, to 46.0 degrees Celsius, in July. Hourly averaged relative humidity ranged from less than 12 percent to over 80 percent. Hourly vapor pressures ranged from 0.06 to 1.71 kilopascals. Daily maximum incident solar radiation values ranged from 149 to 1,084 watts per square meter. Daily mean windspeed ranged from less than 1 to 8.6 meters per second. Monthly wind direction patterns are shown in a series of diagrams in which wind direction is summed over 10-degree arcs from hourly averaged data. Wind direction was primarily from the northwest in fall, winter, and spring and varied from southeast, southwest, or northwest during the summer. Total precipitation for 1989 was 14.0 millimeters, with almost 90 percent occurring from January through May.
40 CFR Table 1 to Subpart Hhhh of... - Minimum Requirements for Monitoring and Recordkeeping
Code of Federal Regulations, 2010 CFR
2010-07-01
...-hour block averages. 2. Other process or control device parameters specified in your OMM b plan. As... value for each product manufactured during the operating day. 6. UF-to-latex ratio in the binder c For... Required if a thermal oxidizer is used to control formaldehyde emissions. b Required if process...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-14
... computed 3-year average ozone concentration of 0.085 ppm is the smallest value that is greater than 0.08..., April 30, 1992; 3. ``Contingency Measures for Ozone and Carbon Monoxide (CO) Redesignations... includes contingency measures to remedy future violations of the 1997 8-hour ozone NAAQS. The maintenance...
Study of surge current effects on solid tantalum capacitors
NASA Technical Reports Server (NTRS)
1980-01-01
Results are presented of a 2,000 hour cycled life test program conducted to determine the effect of short term surge current screening on approximately 47 micron f/volt solid tantalum capacitors. The format provides average values and standard deviations of the parameters, capacitance, dissipation factor, and equivalent series resistance at 120 Hz, 1KHz, abd 40 KHz.
THE SLEEP OF LONG-HAUL TRUCK DRIVERS
Mitler, Merrill M.; Miller, James C.; Lipsitz, Jeffrey J.; Walsh, James K.; Wylie, C. Dennis
2008-01-01
Background Fatigue and sleep deprivation are important safety issues for long-haul truck drivers. Methods We conducted round-the-clock electrophysiologic and performance monitoring of four groups of 20 male truck drivers who were carrying revenue-producing loads. We compared four driving schedules, two in the United States (five 10-hour trips of day driving beginning about the same time each day or of night driving beginning about 2 hours earlier each day) and two in Canada (four 13-hour trips of late-night-to-morning driving beginning at about the same time each evening or of afternoon-to-night driving beginning 1 hour later each day). Results Drivers averaged 5.18 hours in bed per day and 4.78 hours of electrophysiologically verified sleep per day over the five-day study (range, 3.83 hours of sleep for those on the steady 13-hour night schedule to 5.38 hours of sleep for those on the steady 10-hour day schedule). These values compared with a mean (±SD) self-reported ideal amount of sleep of 7.1±1 hours a day. For 35 drivers (44 percent), naps augmented the sleep obtained by an average of 0.45±0.31 hour. No crashes or other vehicle mishaps occurred. Two drivers had undiagnosed sleep apnea, as detected by polysomnography. Two other drivers had one episode each of stage 1 sleep while driving, as detected by electroencephalography. Forty-five drivers (56 percent) had at least 1 six-minute interval of drowsiness while driving, as judged by analysis of video recordings of their faces; 1067 of the 1989 six-minute segments (54 percent) showing drowsy drivers involved just eight drivers. Conclusions Long-haul truck drivers in this study obtained less sleep than is required for alertness on the job. The greatest vulnerability to sleep or sleep-like states is in the late night and early morning. PMID:9287232
Measurement of Refractive Indices of CdSiP2 at Temperatures from 90 to 450 K (Postprint)
2018-01-05
0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...Sellmeier equation was obtained, for the first time to our knowledge over the temperature range 90 to 450 K. The index values were used to calculate...was obtained for the first time to our knowledge over the temperature range 90 to 450 K. The index values were used to calculate the crystal
Griffin, Robert J; Revelle, Meghan K; Dabdub, Donald
2004-02-01
Metrics associated with ozone (O3) formation are investigated using the California Institute of Technology (CIT) three-dimensional air-quality model. Variables investigated include the O3 production rate (P(O3)), O3 production efficiency (OPE), and total reactivity (the sum of the reactivity of carbon monoxide (CO) and all organic gases that react with the hydroxyl radical). Calculations are spatially and temporally resolved; surface-level and vertically averaged results are shown for September 9, 1993 for three Southern California locations: Central Los Angeles, Azusa, and Riverside. Predictions indicate increasing surface-level O3 concentrations with distance downwind, in line with observations. Surface-level and vertically averaged P(O3) values peak during midday and are highest downwind; surface P(O3) values are greater than vertically averaged values. Surface OPEs generally are highest downwind and peak during midday in downwind locations. In contrast, peaks occur in early morning and late afternoon in the vertically averaged case. Vertically averaged OPEs tend to be greater than those for the surface. Total reactivities are highest in upwind surface locations and peak during rush hours; vertically averaged reactivities are smaller and tend to be more uniform temporally and spatially. Total reactivity has large contributions from CO, alkanes, alkenes, aldehydes, unsubstituted monoaromatics, and secondary organics. Calculations using estimated emissions for 2010 result in decreases in P(O3) values and reactivities but increases in OPEs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaustad, K.L.; De Steese, J.G.
A computer program was developed to analyze the viability of integrating superconducting magnetic energy storage (SMES) with proposed wind farm scenarios at a site near Browning, Montana. The program simulated an hour-by-hour account of the charge/discharge history of a SMES unit for a representative wind-speed year. Effects of power output, storage capacity, and power conditioning capability on SMES performance characteristics were analyzed on a seasonal, diurnal, and hourly basis. The SMES unit was assumed to be charged during periods when power output of the wind resource exceeded its average value. Energy was discharged from the SMES unit into the gridmore » during periods of low wind speed to compensate for below-average output of the wind resource. The option of using SMES to provide power continuity for a wind farm supplemented by combustion turbines was also investigated. Levelizing the annual output of large wind energy systems operating in the Blackfeet area of Montana was found to require a storage capacity too large to be economically viable. However, it appears that intermediate-sized SMES economically levelize the wind energy output on a seasonal basis.« less
2014-10-10
Hooge ’s parameters and 1/f noise at the comer frequency for the four wafers are shown in Table 6. We see in the table that the average value of ywas...voltage noise power spectral densities were analyzed and Hooge’s parameters were determined. UNCOOLED MICROBOLOMETER A thermal detector exhibits a...annealing at 200 °C, 250 °C, and 300 °C for duration from 1 hour to 5 hours using a bias current of 0.07 µA. The corresponding Hooge’s parameters for
Work and workload of Dutch primary care midwives in 2010.
Wiegers, Therese A; Warmelink, J Catja; Spelten, Evelien R; Klomp, T; Hutton, Eileen K
2014-09-01
to re-assess the work and workload of primary care midwives in the Netherlands. in the Netherlands most midwives work in primary care as independent practitioners in a midwifery practice with two or more colleagues. Each practice provides 24/7 care coverage through office hours and on-call hours of the midwives. In 2006 the results of a time registration project of primary care midwives were published as part of a 4-year monitor study. This time the registration project was repeated, albeit on a smaller scale, in 2010. as part of a larger study (the Deliver study) all midwives working in 20 midwifery practices kept a time register 24 hours a day, for one week. They also filled out questionnaires about their background, work schedules and experiences of workload. A second component of this study collected data from all midwifery practices in the Netherlands and included questions about practice size (number of midwives and number of clients in the previous year). in 2010, primary care midwives actually worked on an average 32.6 hours per week and approximately 67% of their working time (almost 22 hours per week) was spent on client-related activities. On an average a midwife was on-call for 39 hours a week and almost 13 of the 32.6 hours of work took place during on-call-hours. This means that the total hours that an average midwife was involved in her work (either actually working or on-call) was almost 59 hours a week. Compared to 2004 the number of hours an average midwife was actually working increased by 4 hours (from 29 to 32.6 hours) whereas the total number of hours an average midwife was involved with her work decreased by 6 hours (from 65 to 59 hours). In 2010, compared to 2001-2004, the midwives spent proportionally less time on direct client care (67% versus 73%), although in actual number of hours this did not change much (22 versus 21). In 2009 the average workload of a midwife was 99 clients at booking, 56 at the start of labour, 33 at childbirth, and 90 clients in post partum care. the midwives worked on an average more hours in 2010 than they did in 2004 or 2001, but spent these extra hours increasingly on non-client-related activities. © 2013 Elsevier Ltd. All rights reserved.
78 FR 36199 - Indian Self-Determination and Education Assistance Contracts; Correction
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
... 1 to 1040 hours, with an average of 11 hours per response'' it should read ``Estimated Time per Response: Varies from 1 to 1040 hours, with an average of 15.968 hours per response.'' Dated: June 10, 2013...
5 CFR 550.707 - Computation of severance pay fund.
Code of Federal Regulations, 2011 CFR
2011-01-01
... pay for standby duty regularly varies throughout the year, compute the average standby duty premium...), compute the weekly average percentage, and multiply that percentage by the weekly scheduled rate of pay in... hours in a pay status (excluding overtime hours) and multiply that average by the hourly rate of basic...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
30 CFR 57.5060 - Limit on exposure to diesel particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... diesel particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent... particulate matter (DPM) in an underground mine must not exceed an average eight-hour equivalent full shift... mine must not exceed an average eight-hour equivalent full shift airborne concentration of 350...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kudish, A.I.; Ianetz, A.
1993-12-01
The authors have utilized concurrently measured global, normal incidence beam, and diffuse radiation data, the latter measured by means of a shadow ring pyranometer to study the relative magnitude of the anisotropic contribution (circumsolar region and nonuniform sky conditions) to the diffuse radiation. In the case of Beer Sheva, the monthly average hourly anisotropic correction factor varies from 2.9 to 20.9%, whereas the [open quotes]standard[close quotes] geometric correction factor varies from 5.6 to 14.0%. The monthly average hourly overall correction factor (combined anisotropic and geometric factors) varies from 8.9 to 37.7%. The data have also been analyzed using a simplemore » model of sky radiance developed by Steven in 1984. His anisotropic correction factor is a function of the relative strength and angular width of the circumsolar radiation region. The results of this analysis are in agreement with those previously reported for Quidron on the Dead Sea, viz. the anisotropy and relative strength of the circumsolar radiation are significantly greater than at any of the sites analyzed by Steven. In addition, the data have been utilized to validate a model developed by LeBaron et al. in 1990 for correcting shadow ring diffuse radiation data. The monthly average deviation between the corrected and true diffuse radiation values varies from 4.55 to 7.92%.« less
Investigations of ionospheric sporadic Es layer using oblique sounding method
NASA Astrophysics Data System (ADS)
Minullin, R.
The characteristics of Es layer have been studied using oblique sounding at 28 radiolines at the frequencies of 34 -- 73 MHz at the transmission paths 400 -- 1600 km long during 30 years. Reflections from Es layer with a few hours duration were observed. The amplitude of the reflected signal reached 1000 μ V with the registration threshold 0,1 μ V. The borderlines between reflected and scattered signals were observed as sharp curves in 60 -- 100 s range on the distributions of duration of reflected signals for decameter waves. The duration of continuous Es reflections were decreased upon amplification of oblique sounding frequency. The distributions of duration of reflected signals for meter waves showed sharp curves in the range 200 -- 300 s, representing borderlines between signals reflected from meteoric traces and from Es layer. The filling coefficient for the oblique sounding as well as the Es layer emersion probability for the vertical sounding were shown to undergo daily, seasonal and periodic variations. The daily variations of the filling coefficient of Es signals showed clear-cut maximums at 10 -- 12 and 18 -- 20 hours and minimum at 4 -- 6 hours at all paths in summer time and the maximum at 12 -- 14 hours in winter time. The values of the filling coefficient for Es layer declined with the increase of oblique sounding frequency. The minimal values of the filling coefficient were observed in winter and early spring, while the maximal values were observed from May to August. Provided that the averaged filling coefficient is equal to one in summer, it reaches the level 0,25 in equinox and does not exceed the level 0,12 in winter as evident by the of oblique sounding. The filling coefficient relation to the value of the voltage detection threshold was approximated by power-mode law. The filling coefficients for summer period showed exponential relation with equivalent sounding frequencies. The experimental evidence was generalized in an analytical model. Using this model the averaged Es layer filling coefficients for particular season of the year can be forecasted in case of given sounding frequency, path length, and voltage threshold.
A Comparative Study of Automated Infrasound Detectors - PMCC and AFD with Analyst Review.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Junghyun; Hayward, Chris; Zeiler, Cleat
Automated detections calculated by the progressive multi-channel correlation (PMCC) method (Cansi, 1995) and the adaptive F detector (AFD) (Arrowsmith et al., 2009) are compared to the signals identified by five independent analysts. Each detector was applied to a four-hour time sequence recorded by the Korean infrasound array CHNAR. This array was used because it is composed of both small (<100 m) and large (~1000 m) aperture element spacing. The four hour time sequence contained a number of easily identified signals under noise conditions that have average RMS amplitudes varied from 1.2 to 4.5 mPa (1 to 5 Hz), estimated withmore » running five-minute window. The effectiveness of the detectors was estimated for the small aperture, large aperture, small aperture combined with the large aperture, and full array. The full and combined arrays performed the best for AFD under all noise conditions while the large aperture array had the poorest performance for both detectors. PMCC produced similar results as AFD under the lower noise conditions, but did not produce as dramatic an increase in detections using the full and combined arrays. Both automated detectors and the analysts produced a decrease in detections under the higher noise conditions. Comparing the detection probabilities with Estimated Receiver Operating Characteristic (EROC) curves we found that the smaller value of consistency for PMCC and the larger p-value for AFD had the highest detection probability. These parameters produced greater changes in detection probability than estimates of the false alarm rate. The detection probability was impacted the most by noise level, with low noise (average RMS amplitude of 1.7 mPa) having an average detection probability of ~40% and high noise (average RMS amplitude of 2.9 mPa) average detection probability of ~23%.« less
Motohiro, T; Sakata, Y; Tominaga, K; Oda, K; Aramaki, M; Tanaka, K; Kawakami, A; Shimada, Y; Koga, T; Tomita, S
1988-08-01
Ceftizoxime (CZX), one of the fifth group in cephem-antibiotics classified by Fujii, was administrated intravenously with a one shot dose of 20 mg/kg to neonates and low birth weight infants with ages ranged 4-21 day old and plasma and urinary concentrations and urinary recovery rates of the drug were determined. Clinical, prophylactic and bacteriological effects of CZX were evaluated and adverse reactions and effects on laboratory test values due to this drug were studied in 22 neonates and low birth weight infants (0-76 day old) consisting of 16 cases with various bacterial infections including presumptive cases of bacterial infections and 6 cases with prophylactic administration against infectious diseases. An average CZX daily dose of 55.3 mg/kg was given once or divided into 2-4 times daily (twice: 16 cases, 3 times: 3 cases, 4 times: 2 cases) through intravenous one shot administration for 6 days on the average. The results obtained are summarized as follows. 1. Neonates and low birth weight infants were classified into 3 groups by age: 4-7, 8-14, 15-21 day old. Plasma peak levels of CZX were observed at an average of 5 minutes after administration in all 3 groups with mean values of 58.3, 74.9 and 76.9 micrograms/ml, respectively, and the 4-7 day old-group showed a lower value than with other 2 groups. Mean values of AUC were 218.9, 221.0 and 197.0 micrograms.hr/ml, respectively, and no notable difference was observed within each group. Mean values of half-lives of CZX were 3.61, 2.72 and 2.37 hours, respectively, and the younger group tended to have the longer value. 2. Urinary concentrations of CZX ranged 10.9-1.190 micrograms/ml in all of the 3 groups during 0-2, 2-4, 4-6, 6-8 hours after administration. Mean values of urinary recovery rates during 8 hours of the 3 age-groups were 60.1, 68.7, 56.7%, respectively. The oldest group showed the lowest mean value because one of the cases had the lowest value of 34.5% for an unknown reason. 3. Clinical effect of CZX in 16 cases with various bacterial infections and presumptive bacterial infections was evaluated with an efficacy rate of 87.5%. The prophylactic effect was recognized in all 6 cases that were given CZX to prevent infectious diseases. 4. The bacteriological effect was evaluated in only one case with an infection due to Escherichia coli, which was eradicated by the treatment.(ABSTRACT TRUNCATED AT 250 WORDS)
Effect of positive pulse charge waveforms on the energy efficiency of lead-acid traction cells
NASA Technical Reports Server (NTRS)
Smithrick, J. J.
1981-01-01
The effects of four different charge methods on the energy conversion efficiency of 300 ampere hour lead acid traction cells were investigated. Three of the methods were positive pulse charge waveforms; the fourth, a constant current method, was used as a baseline of comparison. The positive pulse charge waveforms were: 120 Hz full wave rectified sinusoidal; 120 Hz silicon controlled rectified; and 1 kHz square wave. The constant current charger was set at the time average pulse current of each pulse waveform, which was 150 amps. The energy efficiency does not include charger losses. The lead acid traction cells were charged to 70 percent of rated ampere hour capacity in each case. The results of charging the cells using the three different pulse charge waveforms indicate there was no significant difference in energy conversion efficiency when compared to constant current charging at the time average pulse current value.
Solar Resource Assessment for Sri Lanka and Maldives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Renne, D.; George, R.; Marion, B.
2003-08-01
The countries of Sri Lanka and the Maldives lie within the equatorial belt, a region where substantial solar energy resources exist throughout much of the year in adequate quantities for many applications, including solar water heating, solar electricity, and desalination. The extent of solar resources in Sri Lanka has been estimated in the past based on a study of the daily total direct sunshine hours recorded at a number of weather and agricultural stations throughout the country. These data have been applied to the well-known Angstrom relationship in order to obtain an estimate of the distribution of monthly average dailymore » total solar resources at these stations. This study is an effort in improve on these estimates in two ways: (1) to apply a gridded cloud cover database at a 40-km resolution to produce updated monthly average daily total estimates of all solar resources (global horizontal, DNI, and diffuse) for the country, and (2) to input hourly or three-hourly cloud cover observations made at nine weather stations in Sri Lanka and two in the Maldives into a solar model that produces estimates of hourly solar radiation values of the direct normal, global, and diffuse resource covering the length of the observational period. Details and results of these studies are summarized in this report.« less
Compensation for use of monthly-averaged winds in numerical modeling
NASA Technical Reports Server (NTRS)
Parkinson, C. L.
1981-01-01
Ratios R of the monthly averaged wind speeds to the magnitudes of the monthly averaged wind vectors are presented over a 41 x 41 grid covering the southern Ocean and the Antarctic continent. The ratio is found to vary from 1 to over 1000, with an average value of 1.86. These ratios R are relevant for converting from sensible and latent heats calculated with mean monthly data to those calculated with 12 hourly data. The corresponding ratios alpha for wind stress, along with the angle deviations involved, are also presented over the same 41 x 41 grid. The values of alpha generally exceed those for R and average 2.66. Regions in zones of variable wind directions have larger R and alpha ratios, over the ice-covered portions of the southern Ocean averaging 2.74 and 4.35 for R and alpha respectively. Thus adjustments to compensate for the use of mean monthly wind velocities should be stronger for wind stress than for turbulent heats and stronger over ice covered regions than over regions with more persistent wind directions, e.g., those in the belt of mid-latitude westerlies.
NASA Astrophysics Data System (ADS)
1982-03-01
Performance data are given for the month of February, 1982 for a photovoltaic power supply at a Massachusetts high school. Data given include: monthly and daily electrical energy yield; monthly and daily insolation; monthly and daily array efficiency; energy production as a function of power level, voltage, cell temperature, and hour of day; insolation as a function of hour of the day; input, output and efficiency for each of two power conditioning units and for the total power conditioning system; energy supplied to the load by the photovoltaic system and by the grid; photovoltaic system efficiency; dollar value of the energy supplied by the photovoltaic system; capacity factor; daily photovoltaic energy to load; daily system availability and hours of daylight; heating and cooling degree days; hourly cell temperature, ambient temperature, wind speed, and insolation; average monthly wind speed; wind direction distribution; and daily data acquisition mode and recording interval plot.
40 CFR Table 2 to Subpart Dddd of... - Operating Requirements
Code of Federal Regulations, 2011 CFR
2011-07-01
... minimum temperature established during the performance test Maintain the 3-hour block average THC... representative sample of the catalyst at least every 12 months Maintain the 3-hour block average THC... established according to § 63.2262(m) Maintain the 24-hour block average THC concentration a in the biofilter...
40 CFR Table 2 to Subpart Dddd of... - Operating Requirements
Code of Federal Regulations, 2010 CFR
2010-07-01
... minimum temperature established during the performance test Maintain the 3-hour block average THC... representative sample of the catalyst at least every 12 months Maintain the 3-hour block average THC... established according to § 63.2262(m) Maintain the 24-hour block average THC concentration a in the biofilter...
RESPIRATION AND INTENSITY DEPENDENCE OF PHOTOSYNTHESIS IN CHLORELLA
Brackett, Frederick S.; Olson, Rodney A.; Crickard, Robert G.
1953-01-01
1. Respiration changes as a result of illumination. 2. In the absence of glucose or other supply of substrate, respiration decays in the dark showing at least two types—a fast decay in a few minutes and a slow decay lasting hours. 3. Respiratory response to illumination is delayed. 4. Intermittent illumination (in the absence of glucose, etc.) produces a periodic variation in respiration with a delay or phase lag. 5. Periodic variation of respiration may produce a higher average value in the dark than in the light due to the lag and depending upon the period of intermittent illumination. 6. Based upon average respiration values our data confirm the Kok effect. 7. Interpolated values of respiration, however, result in photosynthetic rates which are linearly dependent upon intensity of illumination. 8. Thus the quantum efficiency is found to be independent of intensity, over the wide range of intensities investigated. PMID:13035068
Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review
Viera, Anthony J.; Shimbo, Daichi
2016-01-01
Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387
Code of Federal Regulations, 2013 CFR
2013-01-01
... hours of a U.S. Federal Government employee. This result in the hourly government paid cost of an... average annual leave hours and 1,800 average annual hours available for work for computer manpower...
NASA Astrophysics Data System (ADS)
Bernhardt, Jase; Carleton, Andrew M.
2018-05-01
The two main methods for determining the average daily near-surface air temperature, twice-daily averaging (i.e., [Tmax+Tmin]/2) and hourly averaging (i.e., the average of 24 hourly temperature measurements), typically show differences associated with the asymmetry of the daily temperature curve. To quantify the relative influence of several land surface and atmosphere variables on the two temperature averaging methods, we correlate data for 215 weather stations across the Contiguous United States (CONUS) for the period 1981-2010 with the differences between the two temperature-averaging methods. The variables are land use-land cover (LULC) type, soil moisture, snow cover, cloud cover, atmospheric moisture (i.e., specific humidity, dew point temperature), and precipitation. Multiple linear regression models explain the spatial and monthly variations in the difference between the two temperature-averaging methods. We find statistically significant correlations between both the land surface and atmosphere variables studied with the difference between temperature-averaging methods, especially for the extreme (i.e., summer, winter) seasons (adjusted R2 > 0.50). Models considering stations with certain LULC types, particularly forest and developed land, have adjusted R2 values > 0.70, indicating that both surface and atmosphere variables control the daily temperature curve and its asymmetry. This study improves our understanding of the role of surface and near-surface conditions in modifying thermal climates of the CONUS for a wide range of environments, and their likely importance as anthropogenic forcings—notably LULC changes and greenhouse gas emissions—continues.
LANDSAT-4 horizon scanner full orbit data averages
NASA Technical Reports Server (NTRS)
Stanley, J. P.; Bilanow, S.
1983-01-01
Averages taken over full orbit data spans of the pitch and roll residual measurement errors of the two conical Earth sensors operating on the LANDSAT 4 spacecraft are described. The variability of these full orbit averages over representative data throughtout the year is analyzed to demonstrate the long term stability of the sensor measurements. The data analyzed consist of 23 segments of sensor measurements made at 2 to 4 week intervals. Each segment is roughly 24 hours in length. The variation of full orbit average as a function of orbit within a day as a function of day of year is examined. The dependence on day of year is based on association the start date of each segment with the mean full orbit average for the segment. The peak-to-peak and standard deviation values of the averages for each data segment are computed and their variation with day of year are also examined.
40 CFR Table 1 to Subpart Sssss of... - Emission Limits
Code of Federal Regulations, 2012 CFR
2012-07-01
... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...
40 CFR Table 1 to Subpart Sssss of... - Emission Limits
Code of Federal Regulations, 2013 CFR
2013-07-01
... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...
40 CFR Table 1 to Subpart Sssss of... - Emission Limits
Code of Federal Regulations, 2014 CFR
2014-07-01
... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...
40 CFR Table 1 to Subpart Sssss of... - Emission Limits
Code of Federal Regulations, 2011 CFR
2011-07-01
... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...
40 CFR Table 1 to Subpart Sssss of... - Emission Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...
26 CFR 7.105-2 - Substantial gainful activity.
Code of Federal Regulations, 2010 CFR
2010-04-01
... this nature generally are performed for remuneration or profit. Some weeks the taxpayer works 10 hours, some weeks 40 hours, and over the year the taxpayer works an average of 20 hours per week. Even though... the duties performed and the average number of hours worked per week conclusively establish the...
40 CFR 69.41 - New exemptions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operating specifications. At a minimum, the wind direction data will be monitored, collected and reported as 1-hour averages, starting on the hour. If the average wind direction for a given hour is from within the designated sector, the wind will be deemed to have flowed from within the sector for that hour...
40 CFR 69.41 - New exemptions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operating specifications. At a minimum, the wind direction data will be monitored, collected and reported as 1-hour averages, starting on the hour. If the average wind direction for a given hour is from within the designated sector, the wind will be deemed to have flowed from within the sector for that hour...
50 CFR 218.180 - Specified activity and specified geographical area and effective dates.
Code of Federal Regulations, 2012 CFR
2012-10-01
...-1 RMS-ACL—up to 168 hours over the course of 5 years (an average of 33.5 hours per year); (x) BPAUV...); (vii) AN/WLD-1 RMS-ACL—up to 25 hours over the course of 5 years (an average of 5 hours per year...
50 CFR 218.180 - Specified activity and specified geographical area and effective dates.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-1 RMS-ACL—up to 168 hours over the course of 5 years (an average of 33.5 hours per year); (x) BPAUV...); (vii) AN/WLD-1 RMS-ACL—up to 25 hours over the course of 5 years (an average of 5 hours per year...
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
Dust in the underground railway tunnels of an Italian town.
Ripanucci, G; Grana, M; Vicentini, L; Magrini, A; Bergamaschi, A
2006-01-01
This article assesses hazards associated with exposure to dust in tunnels and platforms of the A and B lines of Rome's underground railway and provides an informed opinion on the risks to workers and the travelling public of exposure to tunnel dust. The study focused on the analysis and measurement of dust granulometric classes PM10, respirable fraction, respirable combustible dust, and the organic, metallic, siliceous, and fibrous components. Comparing the measurement values from the tunnels and platforms with those found at the entrances to the underground railway stations, it emerges that dust concentration in the tunnels and platforms is three times higher, with a maximum PM10 value of 479 microg/m3. Averaged over 24 hours, in relation to the above ground levels, drivers and station staff are exposed to an additional value of 11 microg/m3 and 10 microg/m3, respectively. If commuters were to remain in the trains or on the station platforms, the 24-hour average exposure would increase by 3 microg/m3. Iron and silica were the major components found in the dust. The use of silica sand in the emergency braking system of the carriages is capable of causing a dispersion of quartz in the air in percentages varying from 5% to 14%. Methods are suggested in this article for the reduction of dust dispersion.
78 FR 4759 - Airworthiness Directives; Bell Helicopter Textron, Inc. (Bell) Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-23
.... Reviewing the helicopter records and determining the total factored hours TIS will require about 3 work... inspection and MPI will require about 35 work hours at an average labor rate of $85 per work hour, for a... inspection cycle. To replace a yoke will require about 32 work hours at an average labor rate of $85 per hour...
NASA Technical Reports Server (NTRS)
Hall, S. W.
1980-01-01
Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.
Shin, Kyong-Sok; Chung, Yun Kyung; Kwon, Young-Jun; Son, Jun-Seok; Lee, Se-Hoon
2017-09-01
This study investigated the relationship between weekly working hours and the occurrence of cerebro-cardiovascular diseases using a case-crossover study design. We investigated average working hours during the 7 days before the onset of illness (hazard period) and average weekly working hours between 8 days and 3 months before the onset of cerebro-cardiovascular diseases (control period) for 1,042 cases from the workers' compensation database for 2009. Among all subjects, the odds ratio by conditional logistic regression for the risk of cerebro-cardiovascular diseases with a 10 hr increase in average weekly working hours was 1.45 (95% confidence interval [CI]: 1.22-1.72), a significant association. An increase in average weekly working hours may trigger the onset of cerebro-cardiovascular disease. Am. J. Ind. Med. 60:753-761, 2017. © 2017. Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... posting of the availability of the submittal on EPA's Adequacy Web site (at http://www.epa.gov/otaq... average annual fourth-highest daily maximum 8-hour average ozone concentration), if it had a 1-hour design... ozone standard is attained when the three-year average of the annual fourth-highest daily maximum 8-hour...
40 CFR Table 2 to Subpart Ffff of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part. 2. Carbon monoxide 40 parts per million by dry volume 3-run average (1 hour minimum sample time per run during performance test), and 12-hour rolling averages measured using CEMS b...
40 CFR Table 2 to Subpart Ffff of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part. 2. Carbon monoxide 40 parts per million by dry volume 3-run average (1 hour minimum sample time per run during performance test), and 12-hour rolling averages measured using CEMS b...
40 CFR Table 2 to Subpart Dddd of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... this part) Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample... per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method... appendix A of this part) Oxides of nitrogen 388 parts per million by dry volume 3-run average (1 hour...
Bradley, Beverly D.; Howie, Stephen R. C.; Chan, Timothy C. Y.; Cheng, Yu-Ling
2014-01-01
Background Planning for the reliable and cost-effective supply of a health service commodity such as medical oxygen requires an understanding of the dynamic need or ‘demand’ for the commodity over time. In developing country health systems, however, collecting longitudinal clinical data for forecasting purposes is very difficult. Furthermore, approaches to estimating demand for supplies based on annual averages can underestimate demand some of the time by missing temporal variability. Methods A discrete event simulation model was developed to estimate variable demand for a health service commodity using the important example of medical oxygen for childhood pneumonia. The model is based on five key factors affecting oxygen demand: annual pneumonia admission rate, hypoxaemia prevalence, degree of seasonality, treatment duration, and oxygen flow rate. These parameters were varied over a wide range of values to generate simulation results for different settings. Total oxygen volume, peak patient load, and hours spent above average-based demand estimates were computed for both low and high seasons. Findings Oxygen demand estimates based on annual average values of demand factors can often severely underestimate actual demand. For scenarios with high hypoxaemia prevalence and degree of seasonality, demand can exceed average levels up to 68% of the time. Even for typical scenarios, demand may exceed three times the average level for several hours per day. Peak patient load is sensitive to hypoxaemia prevalence, whereas time spent at such peak loads is strongly influenced by degree of seasonality. Conclusion A theoretical study is presented whereby a simulation approach to estimating oxygen demand is used to better capture temporal variability compared to standard average-based approaches. This approach provides better grounds for health service planning, including decision-making around technologies for oxygen delivery. Beyond oxygen, this approach is widely applicable to other areas of resource and technology planning in developing country health systems. PMID:24587089
Eid, Joseph J; Zendejas, Benjamin; Heller, Stephanie F; Farley, David R
2015-01-01
There is the perceived notion that nondesignated preliminary general surgery (P-GS) interns are treated differently (i.e., overworked) than their categorical GS (C-GS) counterparts are treated, or in an effort to prove themselves worthy of a categorical position, nondesignated preliminary residents may self-choose to work more. Empirical evidence examining duty-hour differences between P-GS and C-GS residents is lacking. We retrospectively reviewed 4 academic years (July 2009 to June 2013) of our self-entered duty-hour database. Duty hours were averaged over 4-week periods and then averaged annually for each intern. Duty-hour averages and the percentage of conference attendance between P-GS and C-GS interns were compared. Sensitivity analyses were conducted to evaluate the effect of the 2011 duty-hour regulations, attendance to educational activities, seasonal variations in workload, and the Match Day effect. A total of 70 P-GS and 43 C-GS interns were compared. Duty-hour averages (±standard deviation, range) were 64.4h/wk (±4.6; 45-70) for the P-GS interns and 64.1h/wk (±3.9; 57-72) for the C-GS interns, p = 0.8. Mean (±standard deviation, range) conference attendance was 61% (±17; 33-89) for the P-GS interns and 66% (±18; 44-85) for the C-GS interns (p = 0.13). Duty-hour averages for both the groups positively correlated with conference attendance (r = 0.27, p = <0.001). The P-GS and the C-GS interns worked on average 4.8 hours more a week after the implementation of the 2011 Accreditation Council of Graduate Medical Education duty-hour regulations when compared with before implementation (66.7 ± 4.1 vs 62 ± 3.1, p < 0.0001), with no difference between both the groups. No seasonal variation in duty hours was encountered for either group. For the P-GS interns, no difference in duty hours was observed before or after the Match Day. At our institution, the P-GS and the C-GS interns have equivalent duty-hour periods and similar conference attendance. An expected, a positive correlation was observed between duty hours and conference attendance. Average weekly duty hours increased by almost 5 hours after the implementation of the 2011 duty-hour regulations. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-07-01
... averages into the appropriate averaging times and units? 60.2943 Section 60.2943 Protection of Environment... SOURCES Operator Training and Qualification Monitoring § 60.2943 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.2975 to calculate...
Code of Federal Regulations, 2012 CFR
2012-07-01
... averages into the appropriate averaging times and units? 60.2943 Section 60.2943 Protection of Environment... SOURCES Operator Training and Qualification Monitoring § 60.2943 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.2975 to calculate...
Code of Federal Regulations, 2011 CFR
2011-07-01
... averages into the appropriate averaging times and units? 60.2943 Section 60.2943 Protection of Environment... SOURCES Operator Training and Qualification Monitoring § 60.2943 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.2975 to calculate...
NASA Technical Reports Server (NTRS)
Bergstrom, Robert W.; Russell, P. B.
2000-01-01
We estimate solar radiative flux changes due to aerosols over the mid-latitude North Atlantic by combining optical depths from AVHRR measurements with aerosol properties from the recent TARFOX program. Results show that, over the ocean the aerosol decreases the net radiative flux at the tropopause and therefore has a cooling effect. Cloud-free, 24-hour average flux changes range from -9 W/sq m near the eastern US coast in summer to -1 W/sq m in the mid-Atlantic during winter. Cloud-free North Atlantic regional averages range from -5.1 W/sq m in summer to -1.7 W/sq m in winter, with an annual average of -3.5 W/sq m. Cloud effects estimated from ISCCP data, reduce the regional annual average to -0.8 W/sq m. All values are for the moderately absorbing TARFOX aerosol (omega(0.55 microns) = 0.9); values for a nonabsorbing aerosol are approx. 30% more negative. We compare our results to a variety of other calculations of aerosol radiative effects.
Deceptive Tactics for Protecting Cities Against Vehicle Borne Improvised Explosive Devices
2008-03-01
burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching...INTENTIONALLY LEFT BLANK xiii LIST OF ABBREVIATIONS ABS Agent Based Simulation ANA Agent Network Attack DVF Detection Value Function GIS Geographic...any other behavior (than perceptive) may be advantageous to the attacker. - A communicative behavior proves particularly effective over time for the
Modal Analysis Using the Singular Value Decomposition and Rational Fraction Polynomials
2017-04-06
information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and...results. The programs are designed for experimental datasets with multiple drive and response points and have proven effective even for systems with... designed for experimental datasets with multiple drive and response points and have proven effective even for systems with numerous closely-spaced
Comparison of population iodine estimates from 24-hour urine and timed-spot urine samples.
Perrine, Cria G; Cogswell, Mary E; Swanson, Christine A; Sullivan, Kevin M; Chen, Te-Ching; Carriquiry, Alicia L; Dodd, Kevin W; Caldwell, Kathleen L; Wang, Chia-Yih
2014-04-01
Median urine iodine concentration (UIC; μg/L) in spot urine samples is recommended for monitoring population iodine status. Other common measures are iodine:creatinine ratio (I/Cr; μg/g) and estimated 24-hour urine iodine excretion (UIE; I/Cr × predicted 24-hour Cr; μg/day). Despite different units, these measures are often used interchangeably, and it is unclear how they compare with the reference standard 24-hour UIE. Volunteers aged 18-39 years collected all their urine samples for 24 hours (n=400). Voids from morning, afternoon, evening, overnight, and a composite 24-hour sample were analyzed for iodine. We calculated median observed 24-hour UIE and 24-hour UIC, and spot UIC, I/Cr, and two measures of estimated UIE calculated using predicted 24-hour Cr from published estimates by Kesteloot and Joosens (varies by age and sex) and published equations by Mage et al. (varies by age, sex, race, and anthropometric measures). We examined mean differences and relative difference across iodine excretion levels using Bland-Altman plots. Median 24-hour UIE was 173.6 μg/day and 24-hour UIC was 144.8 μg/L. From timed-spot urine samples, estimates were: UIC 147.3-156.2 μg/L; I/Cr 103.6-114.3 μg/g, estimated 24-hour UIE (Kesteloot and Joosens) 145.7-163.3 μg/day; and estimated 24-hour UIE (Mage) 176.5-187.7 μg/day. Iodine measures did not vary consistently by timing of spot urine collection. Compared with observed 24-hour UIE, on average, estimated (Mage) 24-hour UIE was not significantly different, while estimated 24-hour UIE (Kesteloot and Joosens) was significantly different for some ethnicity/sex groups. Compared with 24-hour UIC, on average, spot UIC did not differ. Estimates of UIC, I/Cr, and estimated 24-hour UIE (I/Cr × predicted 24-hour Cr) from spot urine samples should not be used interchangeably. Estimated 24-hour UIE, where predicted 24-hour Cr varies by age, sex, ethnicity, and anthropometric measures and was calculated with prediction equations using data from the sample, was more comparable to observed 24-hour UIE than when predicted 24-hour Cr was from published estimates from a different population. However, currently no cutoffs exist to interpret population estimated 24-hour UIE values.
2011-01-01
Artesunate (AS) is a clinically versatile artemisinin derivative utilized for the treatment of mild to severe malaria infection. Given the therapeutic significance of AS and the necessity of appropriate AS dosing, substantial research has been performed investigating the pharmacokinetics of AS and its active metabolite dihydroartemisinin (DHA). In this article, a comprehensive review is presented of AS clinical pharmacokinetics following administration of AS by the intravenous (IV), intramuscular (IM), oral or rectal routes. Intravenous AS is associated with high initial AS concentrations which subsequently decline rapidly, with typical AS half-life estimates of less than 15 minutes. AS clearance and volume estimates average 2 - 3 L/kg/hr and 0.1 - 0.3 L/kg, respectively. DHA concentrations peak within 25 minutes post-dose, and DHA is eliminated with a half-life of 30 - 60 minutes. DHA clearance and volume average between 0.5 - 1.5 L/kg/hr and 0.5 - 1.0 L/kg, respectively. Compared to IV administration, IM administration produces lower peaks, longer half-life values, and higher volumes of distribution for AS, as well as delayed peaks for DHA; other parameters are generally similar due to the high bioavailability, assessed by exposure to DHA, associated with IM AS administration (> 86%). Similarly high bioavailability of DHA (> 80%) is associated with oral administration. Following oral AS, peak AS concentrations (Cmax) are achieved within one hour, and AS is eliminated with a half-life of 20 - 45 minutes. DHA Cmax values are observed within two hours post-dose; DHA half-life values average 0.5 - 1.5 hours. AUC values reported for AS are often substantially lower than those reported for DHA following oral AS administration. Rectal AS administration yields pharmacokinetic results similar to those obtained from oral administration, with the exceptions of delayed AS Cmax and longer AS half-life. Drug interaction studies conducted with oral AS suggest that AS does not appreciably alter the pharmacokinetics of atovaquone/proguanil, chlorproguanil/dapsone, or sulphadoxine/pyrimethamine, and mefloquine and pyronaridine do not alter the pharmacokinetics of DHA. Finally, there is evidence suggesting that the pharmacokinetics of AS and/or DHA following AS administration may be altered by pregnancy and by acute malaria infection, but further investigation would be required to define those alterations precisely. PMID:21914160
NASA Astrophysics Data System (ADS)
Yan, Ying; Zhang, Shen; Tang, Jinjun; Wang, Xiaofei
2017-07-01
Discovering dynamic characteristics in traffic flow is the significant step to design effective traffic managing and controlling strategy for relieving traffic congestion in urban cities. A new method based on complex network theory is proposed to study multivariate traffic flow time series. The data were collected from loop detectors on freeway during a year. In order to construct complex network from original traffic flow, a weighted Froenius norm is adopt to estimate similarity between multivariate time series, and Principal Component Analysis is implemented to determine the weights. We discuss how to select optimal critical threshold for networks at different hour in term of cumulative probability distribution of degree. Furthermore, two statistical properties of networks: normalized network structure entropy and cumulative probability of degree, are utilized to explore hourly variation in traffic flow. The results demonstrate these two statistical quantities express similar pattern to traffic flow parameters with morning and evening peak hours. Accordingly, we detect three traffic states: trough, peak and transitional hours, according to the correlation between two aforementioned properties. The classifying results of states can actually represent hourly fluctuation in traffic flow by analyzing annual average hourly values of traffic volume, occupancy and speed in corresponding hours.
NASA Astrophysics Data System (ADS)
Gaustad, K. L.; Desteese, J. G.
1993-07-01
A computer program was developed to analyze the viability of integrating superconducting magnetic energy storage (SMES) with proposed wind farm scenarios at a site near Browning, Montana. The program simulated an hour-by-hour account of the charge/discharge history of a SMES unit for a representative wind-speed year. Effects of power output, storage capacity, and power conditioning capability on SMES performance characteristics were analyzed on a seasonal, diurnal, and hourly basis. The SMES unit was assumed to be charged during periods when power output of the wind resource exceeded its average value. Energy was discharged from the SMES unit into the grid during periods of low wind speed to compensate for below-average output of the wind resource. The option of using SMES to provide power continuity for a wind farm supplemented by combustion turbines was also investigated. Levelizing the annual output of large wind energy systems operating in the Blackfeet area of Montana was found to require a storage capacity too large to be economically viable. However, it appears that intermediate-sized SMES economically levelize the wind energy output on a seasonal basis.
Self-reporting of internal medicine house staff work hours.
Saunders, David L; Kehoe, Kimberly C; Rinehart, Vivian H; Berg, Benjamin W
2005-01-01
The 80-hour workweek became a reality for residency programs nationwide on July 1, 2003. In this review of administrative data, we examine the self-reporting of work hours by a cohort of Internal Medicine residents. Data was collected from 27 residents in training at Tripler Army Medical Center over a 4 month period from September 1 to December 31 2002. House staff reported their hours on a daily basis by responding to an email message, as well as on a monthly basis utilizing the Army's UCAPERs (Uniform Chart of Account Personnel System) mandatory monthly workload tracking system. Data from the two separate reporting systems was compared for accuracy, completeness and internal consistency. Compliance with daily reporting was variable (67-97% with overall compliance rate of 86%) but lower when compared with the mandatory military monthly reporting system (95-100%). There were large differences in reporting of average weekly work hours among individual residents when monthly reporting was compared to daily reporting of data with higher averages with monthly data reporting. Weekly totals averaged nearly 12 hours higher when reported monthly compared to reporting on a daily basis (p < 0.0001). A total of 18 residents reported that they worked more than 80 hours per week during one month using monthly data, while only 7 reported that they averaged more than 80 hours with the daily reporting data. When average weekly hours reported on a daily basis were compared with the total number of inpatient days worked over the four month period using a simple regression model, there was a significant relationship with average hours increasing with increasing number of inpatient days worked (adjusted R square = 0. 19, p = 0.01). Little internal consistency was found in the comparison of daily versus monthly work hour reporting, indicating that self-reporting may not provide accurate data. Complying with the 80-hour workweek is crucial for residency programs to maintain accreditation, and thus programs will need a way to accurately capture consistent resident work hour data. Further studies are indicated to determine the most accurate way of assessing house staff work hours.
Code of Federal Regulations, 2013 CFR
2013-07-01
... average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4966(a) i. collecting the combustion temperature data according to § 63.4967(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion...
Code of Federal Regulations, 2014 CFR
2014-07-01
... average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4966(a) i. collecting the combustion temperature data according to § 63.4967(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion...
Code of Federal Regulations, 2012 CFR
2012-07-01
... average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4966(a) i. collecting the combustion temperature data according to § 63.4967(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion...
Code of Federal Regulations, 2012 CFR
2012-07-01
... averages into the appropriate averaging times and units? 60.3042 Section 60.3042 Protection of Environment... Construction On or Before December 9, 2004 Model Rule-Monitoring § 60.3042 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.3076 to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... averages into the appropriate averaging times and units? 60.3042 Section 60.3042 Protection of Environment... Construction On or Before December 9, 2004 Model Rule-Monitoring § 60.3042 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.3076 to...
Code of Federal Regulations, 2013 CFR
2013-07-01
... averages into the appropriate averaging times and units? 60.3042 Section 60.3042 Protection of Environment... Construction On or Before December 9, 2004 Model Rule-Monitoring § 60.3042 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.3076 to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... averages into the appropriate averaging times and units? 60.3042 Section 60.3042 Protection of Environment... Construction On or Before December 9, 2004 Model Rule-Monitoring § 60.3042 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.3076 to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... averages into the appropriate averaging times and units? 60.3042 Section 60.3042 Protection of Environment... Construction On or Before December 9, 2004 Model Rule-Monitoring § 60.3042 How do I convert my 1-hour arithmetic averages into the appropriate averaging times and units? (a) Use Equation 1 in § 60.3076 to...
Honjo, T; Yamamoto, S; Yamamoto, T; Kamada, H; Nishida, Y; Tadanaga, O; Asobe, M; Inoue, K
2007-11-26
We report a field trial of differential phase shift quantum key distribution (QKD) using polarization independent frequency up-conversion detectors. A frequency up-conversion detector is a promising device for achieving a high key generation rate when combined with a high clock rate QKD system. However, its polarization dependence prevents it from being applied to practical QKD systems. In this paper, we employ a modified polarization diversity configuration to eliminate the polarization dependence. Applying this method, we performed a long-term stability test using a 17.6-km installed fiber. We successfully demonstrated stable operation for 6 hours and achieved a sifted key generation rate of 120 kbps and an average quantum bit error rate of 3.14 %. The sifted key generation rate was not the estimated value but the effective value, which means that the sifted key was continuously generated at a rate of 120 kbps for 6 hours.
Comparison of Hourly PM2.5 Observations Between Urban and Suburban Areas in Beijing, China.
Yao, Ling; Lu, Ning; Yue, Xiafang; Du, Jia; Yang, Cundong
2015-09-29
Hourly PM2.5 observations collected at 12 stations over a 1-year period are used to identify variations between urban and suburban areas in Beijing. The data demonstrates a unique monthly variation form, as compared with other major cities. Urban areas suffer higher PM2.5 concentration (about 92 μg/m³) than suburban areas (about 77 μg/m³), and the average PM2.5 concentration in cold season (about 105 μg/m³) is higher than warm season (about 78 μg/m³). Hourly PM2.5 observations exhibit distinct seasonal, diurnal and day-of-week variations. The diurnal variation of PM2.5 is observed with higher concentration at night and lower value at daytime, and the cumulative growth of nighttime (22:00 p.m. in winter) PM2.5 concentration maybe due to the atmospheric stability. Moreover, annual average PM2.5 concentrations are about 18 μg/m³ higher on weekends than weekdays, consistent with driving restrictions on weekdays. Additionally, the nighttime peak in weekdays (21:00 p.m.) is one hour later than weekends (20:00 p.m.) which also shows the evidence of human activity. These observed facts indicate that the variations of PM2.5 concentration between urban and suburban areas in Beijing are influenced by complex meteorological factors and human activities.
Comparison of Hourly PM2.5 Observations Between Urban and Suburban Areas in Beijing, China
Yao, Ling; Lu, Ning; Yue, Xiafang; Du, Jia; Yang, Cundong
2015-01-01
Hourly PM2.5 observations collected at 12 stations over a 1-year period are used to identify variations between urban and suburban areas in Beijing. The data demonstrates a unique monthly variation form, as compared with other major cities. Urban areas suffer higher PM2.5 concentration (about 92 μg/m3) than suburban areas (about 77 μg/m3), and the average PM2.5 concentration in cold season (about 105 μg/m3) is higher than warm season (about 78 μg/m3). Hourly PM2.5 observations exhibit distinct seasonal, diurnal and day-of-week variations. The diurnal variation of PM2.5 is observed with higher concentration at night and lower value at daytime, and the cumulative growth of nighttime (22:00 p.m. in winter) PM2.5 concentration maybe due to the atmospheric stability. Moreover, annual average PM2.5 concentrations are about 18 μg/m3 higher on weekends than weekdays, consistent with driving restrictions on weekdays. Additionally, the nighttime peak in weekdays (21:00 p.m.) is one hour later than weekends (20:00 p.m.) which also shows the evidence of human activity. These observed facts indicate that the variations of PM2.5 concentration between urban and suburban areas in Beijing are influenced by complex meteorological factors and human activities. PMID:26426035
Monesi, Valerio
1962-01-01
Mice were injected intraperitoneally with 15 µc of H3-thymidine. The time course of the labeling in spermatogonia and spermatocytes was studied by using autoradiography on 5 µ sections stained by the periodic acid-Schiff method and hematoxylin over a period of 57 hours after injection. Four generations of type A (called AI, AII, AIII, and AIV), one of intermediate, and one of type B spermatogonia occur in one cycle of the seminiferous epithelium. The average life span is about the same in all spermatogonia, i.e., about 27 to 30.5 hours. The average pre-DNA synthetic time, including the mitotic stages from metaphase through telophase and the portion of interphase preceding DNA synthesis, is also not very different, ranging between 7.5 and 10.5 hours. A remarkable difference exists, however, in the duration of DNA synthesis and of the post-DNA synthetic period. The average DNA synthetic time is very long and is highly variable in type B (14.5 hours), a little shorter and less variable in intermediate (12.5 hours) and AIV (13 hours) spermatogonia, and much shorter and very constant in AIII (8 hours), AII and AI (7 to 7.5 hours) spermatogonia. Conversely, the average post-DNA synthetic time, corresponding essentially to the duration of the prophase, is short and very constant in type B (4.5 hours), longer and variable in intermediate (6 hours) and AIV (8 hours) spermatogonia, and much longer and much more variable in AIII (11 hours), AII and AI (14 hours) spermatogonia. The premeiotic synthesis of DNA takes place in primary spermatocytes during the resting phase and terminates just before the visible onset of the meiotic prophase. Its average duration is 14 hours. No further synthesis of DNA takes place in later stages of spermatogenesis. PMID:14475361
29 CFR 548.302 - Average earnings for period other than a workweek.
Code of Federal Regulations, 2010 CFR
2010-07-01
... authorized basic rate for all hours worked in excess of forty in the workweek. The authorized basic rate is... workweek and all his overtime hours are on job No. 2. The employee's average hourly earnings on job No. 2... hours under the act must be determined on a workweek basis. (c) In computing the basic rate under § 548...
ERIC Educational Resources Information Center
Coote, Anna
2010-01-01
A 21-hour working week is a long way from today's standard of 40 hours or more, but not so far-fetched when people consider the infinitely varied ways in which they actually spend their time. On average, people of working age spend 19.6 hours a week in paid employment and 20.4 hours in unpaid housework and childcare. These averages mask huge…
40 CFR Table 2 to Subpart Kkkkk of... - Operating Limits
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Maintain the average scrubber pressure drop for each 3-hour block period at or above the average pressure drop established during the performance test; andb. Maintain the average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test...
Healing Response of a Structural Hamstring Injury: Perfusion Imaging 8-Week Follow-Up.
Kellermann, Marion; Lutter, Christoph; Hotfiel, Thilo
2018-06-18
Hamstring injuries are frequently observed in various sports disciplines both in elite and recreational sport. To quantify intramuscular tissue perfusion via contrast-enhanced ultrasound in the acute phase and during the healing of a structural muscle injury confirmed by high-resolution magnetic resonance imaging. Case study. Laboratory environment. A 32-year-old wakeboarder (height = 176 cm, body weight = 76 kg, and body mass index = 24.5 kg/m 2 ) with an acute indirect muscle injury of the semimembranosus muscle. Average values of quantifiable contrast-enhanced ultrasound, represented as peak enhancement and wash-in area under the curve, as well as conventional ultrasound, 1.5T magnetic resonance imaging were assessed at 48-hour, 3-week, and 8-week postinjury. Average values of the quantitative perfusion analysis at 48-hour and 8-week postinjury revealed an approximate 5-fold increase in peak enhancement, and the wash-in area under the curve increased more than 3-fold in the center of the lesion. Magnetic resonance imaging, performed 48 hours after the injury to gather reference data as gold standard, revealed a grade III structural muscle tear. The authors are able to demonstrate significant changes in intramuscular tissue perfusion in the center of the structural lesion as well as in the adjacent tissue. Quantifiable contrast-enhanced ultrasound seems to be able to gather relevant data for the assessment and monitoring of muscle injuries and could be established as a valuable tool for further studies focusing on healing processes or therapeutic interventions.
NASA Astrophysics Data System (ADS)
Wei, C.; Cheng, K. S.
Using meteorological radar and satellite imagery had become an efficient tool for rainfall forecasting However few studies were aimed to predict quantitative rainfall in small watersheds for flood forecasting by using remote sensing data Due to the terrain shelter and ground clutter effect of Central Mountain Ridges the application of meteorological radar data was limited in mountainous areas of central Taiwan This study devises a new scheme to predict rainfall of a small upstream watershed by combing GOES-9 geostationary weather satellite imagery and ground rainfall records which can be applied for local quantitative rainfall forecasting during periods of typhoon and heavy rainfall Imagery of two typhoon events in 2004 and five correspondent ground raingauges records of Chitou Forest Recreational Area which is located in upstream region of Bei-Shi river were analyzed in this study The watershed accounts for 12 7 square kilometers and altitudes ranging from 1000 m to 1800 m Basin-wide Average Rainfall BAR in study area were estimated by block kriging Cloud Top Temperature CTT from satellite imagery and ground hourly rainfall records were medium correlated The regression coefficient ranges from 0 5 to 0 7 and the value decreases as the altitude of the gauge site increases The regression coefficient of CCT and next 2 to 6 hour accumulated BAR decrease as the time scale increases The rainfall forecasting for BAR were analyzed by Kalman Filtering Technique The correlation coefficient and average hourly deviates between estimated and observed value of BAR for
Olofsson, Sara; Wickström, Anne; Häger Glenngård, Anna; Persson, Ulf; Svenningsson, Anders
2011-10-01
Sweden is a high endemic region for multiple sclerosis (MS), a neurologic disorder characterized by repeated inflammatory episodes affecting the CNS. The disease has its peak age of onset at approximately 30 years and affects women twice as often as men. The young age of onset makes MS one of the major causes of reduced capacity to work due to neurologic disease in Western society. Natalizumab (Tysabri®) is among the new generation of biologic drugs for the treatment of MS. Clinical studies have demonstrated that natalizumab is an effective treatment for preventing relapses and inflammatory activity. The aim of the study was to estimate the monetary value of treatment with natalizumab on the ability to work in patients with MS in Sweden, based on a direct measurement of weekly hours worked before and after 1 year of treatment with natalizumab. A sample of patients, consisting of all patients who had started treatment with natalizumab during the period June 2007-May 2008, was identified through the Swedish Multiple Sclerosis Register (SMSreg). Data about sex, age, disease severity, and disease duration were collected from the register. Data about type of work and work capacity (number of hours worked per week) were collected retrospectively through a postal questionnaire. The average hours worked per week was estimated at baseline (2 weeks before treatment started) and at follow-up (50 weeks after treatment started), and the change was assigned an economic value using the human capital approach. This study showed that after 50 weeks of treatment with natalizumab, people with MS increased their productivity by 3.3 hours per week on average (p < 0.01), which corresponded to an economic value of &U20AC;3216 per person per year (year 2007 values). A shorter duration of illness or being 25-35 years old was significantly associated with a greater productivity gain (p = 0.025 and p = 0.002, respectively). A shorter duration of illness and a lower age at the start of treatment were significantly associated with a greater productivity gain after 50 weeks of treatment with natalizumab, which indicates that it is more beneficial to initiate efficient therapy early in patients with MS.
High-Fidelity Simulations of Moving and Flexible Airfoils at Low Reynolds Numbers (Postprint)
2010-02-01
1 hour per response, including the time for reviewing instructions, searching existing data sources, searching existing data sources, gathering and...maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other...phased-averaged structures for both values of Reynolds number are found to be in good agreement with the experimental data . Finally, the effect of
2008-12-01
average 1 hour per response, including the time for reviewing instruction, searching existing data sources , gathering and maintaining the data needed...Representative for the Contracting Officer on five contracts whose value xii exceeded $200 million and participated on four source selection committees...roles on source selection boards; Consolidated Husbanding Services for all Pacific Ports, Consolidated MWR services for the Pacific, Software
NASA Technical Reports Server (NTRS)
Vaysberg, O. L.; Dyachkov, A. V.; Smirnov, V. N.; Tsyrkin, K. B.; Isaeva, R. A.
1980-01-01
Four electrostatic analyzers with channel electron multipliers as detectors were used to measure solar wind ionic flow. The axes of the fields of vision of two of these analyzers were directed along the axis of the automatic interplanetary station, oriented towards the Sun, while the other two were turned in one plane at angles of +15 deg and -15 deg. The full hemisphere of the angular diagram of each analyzer was approximately 5 deg. The energetic resolution was approximately 6%, and the geometric energy was 0.002 sq cm ave. keV. Each analyzer covered an energetic range of approximately 10 in eight energetic intervals. Spectral distributions were processed in order to obtain the velocity and temperature of the protons. Tabular data show the hour interval (universal time) and the average solar wind velocity in kilometers per second.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Biomass—6.2 parts per million dry volumeCoal—650 parts per million dry volume 3-run average (1 hour... Biomass—290 parts per million dry volumeCoal—340 parts per million dry volume 3-run average (1 hour... volume Biomass—240 parts per million dry volumeCoal—95 parts per million dry volume 3-run average (1 hour...
Code of Federal Regulations, 2012 CFR
2012-07-01
... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10... (Reapproved 2008) c. Oxides of nitrogen 53 parts per million dry volume 3-run average (1 hour minimum sample... average (1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix...
Code of Federal Regulations, 2011 CFR
2011-07-01
... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10... (Reapproved 2008) c. Oxides of nitrogen 53 parts per million dry volume 3-run average (1 hour minimum sample... average (1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix...
Use and limitations of ASHRAE solar algorithms in solar energy utilization studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sowell, E.F.
1978-01-01
Algorithms for computer calculation of solar radiation based on cloud cover data, recommended by the ASHRAE Task Group on Energy Requirements for Buildings, are examined for applicability in solar utilization studies. The implementation is patterned after a well-known computer program, NBSLD. The results of these algorithms, including horizontal and tilted surface insolation and useful energy collectable, are compared to observations and results obtainable by the Liu and Jordan method. For purposes of comparison, data for Riverside, CA from 1960 through 1963 are examined. It is shown that horizontal values so predicted are frequently less than 10% and always less thanmore » 23% in error when compared to averages of hourly measurements during important collection hours in 1962. Average daily errors range from -14 to 9% over the year. When averaged on an hourly basis over four years, there is a 21% maximum discrepancy compared to the Liu and Jordan method. Corresponding tilted-surface discrepancies are slightly higher, as are those for useful energy collected. Possible sources of these discrepancies and errors are discussed. Limitations of the algorithms and various implementations are examined, and it is suggested that certain assumptions acceptable for building loads analysis may not be acceptable for solar utilization studies. In particular, it is shown that the method of separatingg diffuse and direct components in the presence of clouds requires careful consideration in order to achieve accuracy and efficiency in any implementation.« less
40 CFR 63.1975 - How do I calculate the 3-hour block average used to demonstrate compliance?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I calculate the 3-hour block average used to demonstrate compliance? 63.1975 Section 63.1975 Protection of Environment ENVIRONMENTAL... block average used to demonstrate compliance? Averages are calculated in the same way as they are...
Martínez-García, Miguel-Angel; Capote, Francisco; Campos-Rodríguez, Francisco; Lloberes, Patricia; Díaz de Atauri, María Josefa; Somoza, María; Masa, Juan F; González, Mónica; Sacristán, Lirios; Barbé, Ferrán; Durán-Cantolla, Joaquín; Aizpuru, Felipe; Mañas, Eva; Barreiro, Bienvenido; Mosteiro, Mar; Cebrián, Juan J; de la Peña, Mónica; García-Río, Francisco; Maimó, Andrés; Zapater, Jordi; Hernández, Concepción; Grau SanMarti, Nuria; Montserrat, Josep María
2013-12-11
More than 70% of patients with resistant hypertension have obstructive sleep apnea (OSA). However, there is little evidence about the effect of continuous positive airway pressure (CPAP) treatment on blood pressure in patients with resistant hypertension. To assess the effect of CPAP treatment on blood pressure values and nocturnal blood pressure patterns in patients with resistant hypertension and OSA. Open-label, randomized, multicenter clinical trial of parallel groups with blinded end point design conducted in 24 teaching hospitals in Spain involving 194 patients with resistant hypertension and an apnea-hypopnea index (AHI) of 15 or higher. Data were collected from June 2009 to October 2011. CPAP or no therapy while maintaining usual blood pressure control medication. The primary end point was the change in 24-hour mean blood pressure after 12 weeks. Secondary end points included changes in other blood pressure values and changes in nocturnal blood pressure patterns. Both intention-to-treat (ITT) and per-protocol analyses were performed. A total of 194 patients were randomly assigned to receive CPAP (n = 98) or no CPAP (control; n = 96). The mean AHI was 40.4 (SD, 18.9) and an average of 3.8 antihypertensive drugs were taken per patient. Baseline 24-hour mean blood pressure was 103.4 mm Hg; systolic blood pressure (SBP), 144.2 mm Hg; and diastolic blood pressure (DBP), 83 mm Hg. At baseline, 25.8% of patients displayed a dipper pattern (a decrease of at least 10% in the average nighttime blood pressure compared with the average daytime blood pressure). The percentage of patients using CPAP for 4 or more hours per day was 72.4%. When the changes in blood pressure over the study period were compared between groups by ITT, the CPAP group achieved a greater decrease in 24-hour mean blood pressure (3.1 mm Hg [95% CI, 0.6 to 5.6]; P = .02) and 24-hour DBP (3.2 mm Hg [95% CI, 1.0 to 5.4]; P = .005), but not in 24-hour SBP (3.1 mm Hg [95% CI, -0.6 to 6.7]; P = .10) compared with the control group. Moreover, the percentage of patients displaying a nocturnal blood pressure dipper pattern at the 12-week follow-up was greater in the CPAP group than in the control group (35.9% vs 21.6%; adjusted odds ratio [OR], 2.4 [95% CI, 1.2 to 5.1]; P = .02). There was a significant positive correlation between hours of CPAP use and the decrease in 24-hour mean blood pressure (r = 0.29, P = .006), SBP (r = 0.25; P = .02), and DBP (r = 0.30, P = .005). Among patients with OSA and resistant hypertension, CPAP treatment for 12 weeks compared with control resulted in a decrease in 24-hour mean and diastolic blood pressure and an improvement in the nocturnal blood pressure pattern. Further research is warranted to assess longer-term health outcomes. clinicaltrials.gov Identifier: NCT00616265.
Wood, Carla; Diehm, Emily A; Callender, Maya F
2016-04-01
The current study was designed to (a) describe average hourly Language Environment Analysis (LENA) data for preschool-age Spanish-English bilinguals (SEBs) and typically developing monolingual peers and (b) compare LENA data with mean length of utterance in words (MLUw) and total number of words (TNW) calculated on a selected sample of consecutive excerpts of audio files (CEAFs). Investigators examined average hourly child vocalizations from daylong LENA samples for 42 SEBs and 39 monolingual English-speaking preschoolers. The relationship between average hourly child vocalizations, conversational turns, and adult words from the daylong samples and MLUw from a 50-utterance CEAF was examined and compared between groups. MLUw, TNW, average hourly child vocalizations, and conversational turns were lower for young SEBs than monolingual English-speaking peers. Average hourly child vocalizations were not strongly related to MLUw performance for monolingual or SEB participants (r = .29, r = .25, respectively). In a similar manner, average hourly conversational turns were not strongly related to MLUw for either group (r = .22, r = .21, respectively). Young SEBs from socioeconomically disadvantaged backgrounds showed lower average performance on LENA measures, MLUw, and TNW than monolingual English-speaking peers. MLUw from monolinguals were also lower than typical expectations when derived from CEAFs. LENA technology may be a promising tool for communication sampling with SEBs; however, more research is needed to establish norms for interpreting MLUw and TNW from selected CEAF samples.
NASA Astrophysics Data System (ADS)
Moon, Ga-Hee
2011-06-01
It is generally believed that the occurrence of a magnetic storm depends upon the solar wind conditions, particularly the southward interplanetary magnetic field (IMF) component. To understand the relationship between solar wind parameters and magnetic storms, variations in magnetic field polarity and solar wind parameters during magnetic storms are examined. A total of 156 storms during the period of 1997~2003 are used. According to the interplanetary driver, magnetic storms are divided into three types, which are coronal mass ejection (CME)-driven storms, co-rotating interaction region (CIR)-driven storms, and complicated type storms. Complicated types were not included in this study. For this purpose, the manner in which the direction change of IMF By and Bz components (in geocentric solar magnetospheric coordinate system coordinate) during the main phase is related with the development of the storm is examined. The time-integrated solar wind parameters are compared with the time-integrated disturbance storm time (Dst) index during the main phase of each magnetic storm. The time lag with the storm size is also investigated. Some results are worth noting: CME-driven storms, under steady conditions of Bz < 0, represent more than half of the storms in number. That is, it is found that the average number of storms for negative sign of IMF Bz (T1~T4) is high, at 56.4%, 53.0%, and 63.7% in each storm category, respectively. However, for the CIR-driven storms, the percentage of moderate storms is only 29.2%, while the number of intense storms is more than half (60.0%) under the Bz < 0 condition. It is found that the correlation is highest between the time-integrated IMF Bz and the time-integrated Dst index for the CME-driven storms. On the other hand, for the CIR-driven storms, a high correlation is found, with the correlation coefficient being 0.93, between time-integrated Dst index and time-integrated solar wind speed, while a low correlation, 0.51, is found between timeintegrated Bz and time-integrated Dst index. The relationship between storm size and time lag in terms of hours from Bz minimum to Dst minimum values is investigated. For the CME-driven storms, time lag of 26% of moderate storms is one hour, whereas time lag of 33% of moderate storms is two hours for the CIR-driven storms. The average values of solar wind parameters for the CME and CIR-driven storms are also examined. The average values of |Dstmin| and |Bzmin| for the CME-driven storms are higher than those of CIR-driven storms, while the average value of temperature is lower.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... (e) Average weekly hours means a figure obtained by dividing: (1) Total hours worked (excluding... employment. (f) Average weekly wage means one-thirteenth of the total wages paid to an individual in the... preceding the individual's appropriate week. (g) Average weekly wage in adversely affected employment means...
Economic productivity by age and sex: 2007 estimates for the United States.
Grosse, Scott D; Krueger, Kurt V; Mvundura, Mercy
2009-07-01
Human capital estimates of labor productivity are often used to estimate the economic impact of diseases and injuries that cause incapacitation or death. Estimates of average hourly, annual, and lifetime economic productivity, both market and household, were calculated in 2007 US dollars for 5-year age groups for men, women, and both sexes in the United States. Data from the American Time Use Survey were used to estimate hours of paid work and household services and hourly and annual earnings and household productivity. Present values of discounted lifetime earnings were calculated for each age group using the 2004 US life tables and a discount rate of 3% per year and assuming future productivity growth of 1% per year. The estimates of hours and productivity were calculated using the time diaries of 72,922 persons included in the American Time Use Survey for the years 2003 to 2007. The present value of lifetime productivity is approximately $1.2 million in 2007 dollars for children under 5 years of age. For adults in their 20s and 30s, it is approximately $1.6 million and then it declines with increasing age. Productivity estimates are higher for males than for females, more for market productivity than for total productivity. Changes in hours of paid employment and household services can affect economic productivity by age and sex. This is the first publication to include estimates of household services based on contemporary time use data for the US population.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1973-01-01
The capacity of the cells ranged from 3.58 to 3.97 amperehours during the three capacity tests. Three cells were removed from test, due to high pressure, during the C/10, 24-hour charge at room ambient temperature. The voltage requirement of 1.480 volts was exceeded by the cells during the C/10, 24-hour charge at 20 C, although the end-of-charge voltage was below this value (1.466-1.475 volts). Average capacity out during the 20 C charge efficiency test was 0.84 AH which represents 48% and is below the minimum requirement of 55%. The cells exhibited no pressure decay during the open-circuit stand portion of the pressure versus capacity test, as all cells reached their voltage limit (1.550 volts) before their pressure reached 20 psia with the highest pressure being 8 psia during charge.
Monroe, James I; Boparai, Karan; Xiao, Ying; Followill, David; Galvin, James M; Klein, Eric E; Low, Daniel A; Moran, Jean M; Zhong, Haoyu; Sohn, Jason W
2018-02-04
A survey was created by NRG to assess a medical physicists' percent full time equivalent (FTE) contribution to multi-institutional clinical trials. A 2012 American Society for Radiation Oncology report, "Safety Is No Accident," quantified medical physics staffing contributions in FTE factors for clinical departments. No quantification of FTE effort associated with clinical trials was included. To address this lack of information, the NRG Medical Physics Subcommittee decided to obtain manpower data from the medical physics community to quantify the amount of time medical physicists spent supporting clinical trials. A survey, consisting of 16 questions, was designed to obtain information regarding physicists' time spent supporting clinical trials. The survey was distributed to medical physicists at 1996 radiation therapy institutions included on the membership rosters of the 5 National Clinical Trials Network clinical trial groups. Of the 451 institutions who responded, 50% (226) reported currently participating in radiation therapy trials. On average, the designated physicist at each institution spent 2.4 hours (standard deviation [SD], 5.5) per week supervising or interacting with clinical trial staff. On average, 1.2 hours (SD, 3.1), 1.8 hours (SD, 3.9), and 0.6 hours (SD, 1.1) per week were spent on trial patient simulations, treatment plan reviews, and maintaining a Digital Imaging and Communications in Medicine server, respectively. For all trial credentialing activities, physicists spent an average of 32 hours (SD, 57.2) yearly. Reading protocols and supporting dosimetrists, clinicians, and therapists took an average of 2.1 hours (SD, 3.4) per week. Physicists also attended clinical trial meetings, on average, 1.2 hours (SD, 1.9) per month. On average, physicist spent a nontrivial total of 9 hours per week (0.21 FTE) supporting an average of 10 active clinical trials. This time commitment indicates the complexity of radiation therapy clinical trials and should be taken into account when staffing radiation therapy institutions. Copyright © 2018 Elsevier Inc. All rights reserved.
40 CFR Table 2 to Subpart Ppppp of... - Operating Limits
Code of Federal Regulations, 2011 CFR
2011-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.9324(a) i. Collecting the combustion temperature data according to § 63.9306(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour average combustion temperature...
40 CFR Table 2 to Subpart Ppppp of... - Operating Limits
Code of Federal Regulations, 2014 CFR
2014-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.9324(a) i. Collecting the combustion temperature data according to § 63.9306(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour average combustion temperature...
40 CFR Table 2 to Subpart Ppppp of... - Operating Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.9324(a) i. Collecting the combustion temperature data according to § 63.9306(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour average combustion temperature...
40 CFR Table 2 to Subpart Ppppp of... - Operating Limits
Code of Federal Regulations, 2013 CFR
2013-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.9324(a) i. Collecting the combustion temperature data according to § 63.9306(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour average combustion temperature...
40 CFR Table 2 to Subpart Ppppp of... - Operating Limits
Code of Federal Regulations, 2012 CFR
2012-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.9324(a) i. Collecting the combustion temperature data according to § 63.9306(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour average combustion temperature...
5 CFR 550.707 - Computation of severance pay fund.
Code of Federal Regulations, 2010 CFR
2010-01-01
... hours in the employee's basic work schedule (excluding overtime hours) varies during the year because of part-time work requirements, compute the weekly average of those hours and multiply that average by the... differential pay under 5 U.S.C. 5343(f) varies from week to week under a regularly recurring cycle of work...
40 CFR 62.15305 - What records must I keep for continuously monitored pollutants or parameters?
Code of Federal Regulations, 2014 CFR
2014-07-01
... oxides emissions. (4) All 1-hour average concentrations of carbon monoxide emissions. (5) All 1-hour... carbon monoxide emissions. (4) All 4-hour block arithmetic average load levels of your municipal waste... combustion units only, nitrogen oxides emissions. (iii) Carbon monoxide emissions. (iv) Load levels of your...
29 CFR 1910.1047 - Ethylene oxide.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (8)-hour time-weighted average. Assistant Secretary means the Assistant Secretary of Labor for... organic compound with chemical formula C2 H4 O. (c) Permissible exposure limits—(1) 8-hour time weighted... in excess of one (1) part EtO per million parts of air (1 ppm) as an 8-hour time-weighted average (8...
29 CFR 1910.1047 - Ethylene oxide.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (8)-hour time-weighted average. Assistant Secretary means the Assistant Secretary of Labor for... organic compound with chemical formula C2 H4 O. (c) Permissible exposure limits—(1) 8-hour time weighted... in excess of one (1) part EtO per million parts of air (1 ppm) as an 8-hour time-weighted average (8...
29 CFR 1910.1047 - Ethylene oxide.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (8)-hour time-weighted average. Assistant Secretary means the Assistant Secretary of Labor for... organic compound with chemical formula C2 H4 O. (c) Permissible exposure limits—(1) 8-hour time weighted... in excess of one (1) part EtO per million parts of air (1 ppm) as an 8-hour time-weighted average (8...
2007-08-01
primary somatotypes , which were identified by multivariate analysis, had no significant effect on the simulated thermo-physiological responses ...population. Anthropometric values for each somatotype applied to a thermal regulatory model resulted into physiological response comparisons of Figure 2 and...Public report ing burden for this collect ion of information is est imated to average 1 hour per response , including the time for review ing instruct ions
The Cost of Commonality: Assessing Value in Joint Programs
2015-12-01
this collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data ...sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden...economies of scale in order to provide cheaper goods. When those economies of scale are not realized, as was the case with the U.S. auto market “ Big Three
A Design of Experiments Approach to Readiness Risk Analysis for Performance-Based Logistics
2006-09-30
valuing proposed improvements in component reliability. Sponsored report NPS-LM 05-008. Monterey, CA: Graduate School of Business and Public Policy...Postgraduate School aval Postgraduate School ase, distribution unlimited. School, Monterey, California 93943 ê~ã= pp=C=mr_if`=mlif`v= i= Report ...Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response
Precision gravity studies at Cerro Prieto: a progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grannell, R.B.; Kroll, R.C.; Wyman, R.M.
A third and fourth year of precision gravity data collection and reduction have now been completed at the Cerro Prieto geothermal field. In summary, 66 permanently monumented stations were occupied between December and April of 1979 to 1980 and 1980 to 1981 by a LaCoste and Romberg gravity meter (G300) at least twice, with a minimum of four replicate values obtained each time. Station 20 alternate, a stable base located on Cerro Prieto volcano, was used as the reference base for the third year and all the stations were tied to this base, using four to five hour loops. Themore » field data were reduced to observed gravity values by (1) multiplication with the appropriate calibration factor; (2) removal of calculated tidal effects; (3) calculation of average values at each station, and (4) linear removal of accumulated instrumental drift which remained after carrying out the first three reductions. Following the reduction of values and calculation of gravity differences between individual stations and the base stations, standard deviations were calculated for the averaged occupation values (two to three per station). In addition, pooled variance calculations were carried out to estimate precision for the surveys as a whole.« less
The Budget and Economic Outlook: Fiscal Years 2010 to 2020
2010-01-01
Participation Rate 352-10. Average Weekly Hours Worked in the Nonfarm Business Sector 352-11. People Who Have Lost Jobs as a Percentage of All Unemployed...in the past they have not lasted more than a few quarters. Figure 2-10. Average Weekly Hours Worked in the Nonfarm Business Sector (Hours per week...in the nonfarm business sector , which accounts for about three-fourths of the economy, are projected to grow at an average annual rate of 0.5 per
Decreasing trends of suspended particulate matter and PM2.5 concentrations in Tokyo, 1990-2010.
Hara, Kunio; Homma, Junichi; Tamura, Kenji; Inoue, Mariko; Karita, Kanae; Yano, Eiji
2013-06-01
In Tokyo, the annual average suspended particulate matter (SPM) and PM2.5 concentrations have decreased in the past two decades. The present study quantitatively evaluated these decreasing trends using data from air-pollution monitoring stations. Annual SPM and PM2.5 levels at 83 monitoring stations and hourly SPM and PM2.5 levels at four monitoring stations in Tokyo, operated by the Tokyo Metropolitan Government, were used for analysis, together with levels of co-pollutants and meteorological conditions. Traffic volume in Tokyo was calculated from the total traveling distance of vehicles as reported by the Ministry of Land, Infrastructure, Transport, and Tourism. High positive correlations between SPM levels and nitrogen oxide levels, sulfur dioxide levels, and traffic volume were determined. The annual average SPM concentration declined by 62.6%from 59.4 microg/m3 in 1994 to 22.2 microg/m3 in 2010, and PM2.5 concentration also declined by 49.8% from 29.3 microg/m3 in 2001 to 14.7 microg/m3 in 2010. Likewise, the frequencies of hourly average SPM and PM2.5 concentrations exceeding the daily guideline values have significantly decreased since 2001 and the hourly average SPM or PM2.5 concentrations per traffic volume for each time period have also significantly decreased since 2001. However SPM and PM2.5 concentrations increased at some monitoring stations between 2004 and 2006 and from 2009 despite strengthened environmental regulations and improvements in vehicle engine performance. The annual average SPM and PM2.5 concentrations were positively correlated with traffic volumes and in particular with the volume of diesel trucks. These results suggest that the decreasing levels of SPM and PM2.5 in Tokyo may be attributable to decreased traffic volumes, along with the effects of stricter governmental regulation and improvements to vehicle engine performance, including the fitting of devices for exhaust emission reduction.
Assessing the features of extreme smog in China and the differentiated treatment strategy
NASA Astrophysics Data System (ADS)
Deng, Lu; Zhang, Zhengjun
2018-01-01
Extreme smog can have potentially harmful effects on human health, the economy and daily life. However, the average (mean) values do not provide strategically useful information on the hazard analysis and control of extreme smog. This article investigates China's smog extremes by applying extreme value analysis to hourly PM2.5 data from 2014 to 2016 obtained from monitoring stations across China. By fitting a generalized extreme value (GEV) distribution to exceedances over a station-specific extreme smog level at each monitoring location, all study stations are grouped into eight different categories based on the estimated mean and shape parameter values of fitted GEV distributions. The extreme features characterized by the mean of the fitted extreme value distribution, the maximum frequency and the tail index of extreme smog at each location are analysed. These features can provide useful information for central/local government to conduct differentiated treatments in cities within different categories and conduct similar prevention goals and control strategies among those cities belonging to the same category in a range of areas. Furthermore, hazardous hours, breaking probability and the 1-year return level of each station are demonstrated by category, based on which the future control and reduction targets of extreme smog are proposed for the cities of Beijing, Tianjin and Hebei as an example.
Cornélissen, G; Halberg, F; Beaty, L; Kumagai, Y; Halberg, E; Halberg, J; Lee, J; Schwartzkopff, O; Otsuka, K
2009-01-01
An increase in the circadian amplitude (A) of blood pressure (BP) had been reported to precede a rise in the circadian BP average (MESOR, M), as pre-hypertension in the stroke-prone Okamoto rat. In humans, children with a positive family history of high BP and/or related cardiovascular disease had, on average, a larger BP-A than children with a negative family history, and an elevated BP-A was associated with intermediate values of the left ventricular mass index (LVMI), whereas an elevation in BP-M was only observed for larger LVMI values. Against this background, with 24-hour ambulatory monitoring (ABPM) interpreted chronobiologically, Pietro Cugini (University La Sapienza of Rome, Italy) has reported an elevation of both the circadian BP-M and BP-A as occurring with a minimal change (hypertensive) retinopathy. He determined by cosinor the extent of predictable BP change within a day as BP-2A, estimated by the least squares fit of a 24-hour cosine curve to the data. As compared to controls without retinopathy, he found a retinal end-organ involvement associated with average systolic (S) / diastolic (D) BP-Ms of 124/76 vs. 112/72 mmHg, with corresponding SBP/DBP-As of 12/10 vs. 8/7 mmHg. We refer to "Cugini's syndrome", suggesting the need for clarification, preferably in longitudinal studies, of any generalizable sequence in end-organ involvement, that may occur in the course of the development of some human Vascular Variability Disorders (VVDs) of unknown etiology, that include an elevation of the circadian BP-A and/or BP-M, concomitantly or separately in a sequence with the BP-A increase preceding that in BP-M, as in models of high BP in the rat or vice versa. Seven-day half-hourly or hourly around-the-clock monitoring of BP and HR variability interpreted chronobiologically, C-ABPM, as a minimum, is recommended for routine medical care to detect VVDs consisting of 1. MESOR-hypertension, MH; 2. Circadian Hyper-Amplitude-Tension, CHAT (BP overswing); 3. odd timing of the circadian rhythm of BP but not that of HR; 4. above-threshold pulse pressure; and/or 5. below-threshold HR variability. All conditions are best determined by 24-hour/7-day or, when abnormality is detected, longer C-ABPM. Eventually, all conditions will need to be assessed in the light of reference values from gender- and age-matched peers, as is now the case for the fi rst three VVDs listed above. When C-ABPM is not practicable, a 7-day series of 3-hourly manual self-measurements during waking (and one measurement about mid-sleep) (C-MBPM) is recommended. When continuous monitoring becomes possible, as it is within the state of the science, detecting Cugini's syndrome will also become possible with the clarification as to whether any change in BP-M and/or BP-A occurs concomitantly or sequentially, with changes in BP-A anticipated to precede changes in BP-M.
Productivity standards for histology laboratories.
Buesa, René J
2010-04-01
The information from 221 US histology laboratories (histolabs) and 104 from 24 other countries with workloads from 600 to 116 000 cases per year was used to calculate productivity standards for 23 technical and 27 nontechnical tasks and for 4 types of work flow indicators. The sample includes 254 human, 40 forensic, and 31 veterinary pathology services. Statistical analyses demonstrate that most productivity standards are not different between services or worldwide. The total workload for the US human pathology histolabs averaged 26 061 cases per year, with 54% between 10 000 and less than 30 000. The total workload for 70% of the histolabs from other countries was less than 20 000, with an average of 15 226 cases per year. The fundamental manual technical tasks in the histolab and their productivity standards are as follows: grossing (14 cases per hour), cassetting (54 cassettes per hour), embedding (50 blocks per hour), and cutting (24 blocks per hour). All the other tasks, each with their own productivity standards, can be completed by auxiliary staff or using automatic instruments. Depending on the level of automation of the histolab, all the tasks derived from a workload of 25 cases will require 15.8 to 17.7 hours of work completed by 2.4 to 2.7 employees with 18% of their working time not directly dedicated to the production of diagnostic slides. This article explains how to extrapolate this productivity calculation for any workload and different levels of automation. The overall performance standard for all the tasks, including 8 hours for automated tissue processing, is 3.2 to 3.5 blocks per hour; and its best indicator is the value of the gross work flow productivity that is essentially dependent on how the work is organized. This article also includes productivity standards for forensic and veterinary histolabs, but the staffing benchmarks for histolabs will be the subject of a separate article. Copyright 2010 Elsevier Inc. All rights reserved.
The cost and value of pre-registration clinical placements for Project 2000 students.
Jones, M L; Akehurst, R
1999-07-01
The research outlined in this article was commissioned by the Sheffield and North Trent College of Nursing and Midwifery to explore the cost implications of pre-registration clinical placements in the context of Project 2000. The authors outline the methodology and findings of an exercise designed to collect relevant cost information which was not readily available. On the basis of these findings, they suggest that: at 1995/1996 pay and prices, clinical placements cost the education provider approximately pound 890 per student per annum; in terms of real resources, the value to service providers of the service contribution made by second- and third-year nursing and midwifery students on ward-based placements outweighs the value of the time spent by qualified staff on their supervision and education. Once the funding assumptions underlying the introduction of Project 2000 have been taken into account, second- and third-year nursing and midwifery students benefit the service provider by on average pound 3.46 for every hour they spend in an unrostered ward-based placement. The service contribution made by students in community-based clinical placements cannot free staff time in the same way as on the wards and, because qualified staff in these areas are generally more highly graded, the value of the time they spend on the supervision and education of students on placement is higher than in ward-based placements. Second- and third-year students therefore appear to cost the service provider on average pound 0.48 for each hour they spend in a community-based placement. It was not possible to determine whether this cost translates into a reduction in patient contacts.
Watts, Susan H; Promes, Susan B; Hockberger, Robert
2012-07-01
he objective was to report the results of a survey conducted jointly by the Society for Academic Emergency Medicine (SAEM) and the Association of Academic Chairs in Emergency Medicine (AACEM) of faculty salaries, benefits, work hours, and department demographics for institutions sponsoring residency programs accredited by the Accreditation Council for Graduate Medical Education (ACGME) Residency Review Committee for Emergency Medicine (RRC-EM). Data represent information collected for the 2009-2010 academic year through an electronic survey developed by SAEM and AACEM and distributed by the Office for Survey Research at the University of Michigan to all emergency department (ED) chairs and chiefs at institutions sponsoring accredited residency programs. Information was collected regarding faculty salaries and benefits; clinical and nonclinical work hours; sources of department income and department expenses; and selected demographic information regarding faculty, EDs, and hospitals. Salary data were sorted by program geographic region and faculty characteristics such as training and board certification, academic rank, department title, and sex. Demographic data were analyzed with regard to numerous criteria, including ED staffing levels, patient volumes and length of stay, income sources, salary incentive components, research funding, and specific type and value of fringe benefits offered. Data were compared with previous SAEM studies and the most recent faculty salary survey conducted by the Association of American Medical Colleges (AAMC). Ninety-four of 155 programs (61%) responded, yielding salary data on 1,644 faculty, of whom 1,515 (92%) worked full-time. The mean salary for all faculty nationwide was $237,884, with the mean ranging from $232,819 to $246,853 depending on geographic region. The mean salary for first-year faculty nationwide was $204,833. Benefits had an estimated mean value of $48,915 for all faculty, with the mean ranging from $37,813 to $55,346 depending on geographic region. The following factors are associated with higher salaries: emergency medicine (EM) residency training and board certification, fellowship training in toxicology and hyperbaric medicine, higher academic rank, male sex, and living in the western and southern regions. Full-time EM faculty work an average of 20 to 23 clinical hours and 16 to 19 nonclinical hours per week. The salaries for full-time EM faculty reported in this survey were higher than those found in the AAMC survey for the same time period in the majority of categories for both academic rank and geographic region. On average, female faculty are paid 10% to 13% less than their male counterparts. Full-time EM faculty work an average of 20 to 23 clinical hours and 16 to 19 nonclinical hours per week, which is similar to the work hours reported in previous SAEM surveys. © 2012 by the Society for Academic Emergency Medicine.
Temporal Patterns in Seawater Quality from Dredging in Tropical Environments.
Jones, Ross; Fisher, Rebecca; Stark, Clair; Ridd, Peter
2015-01-01
Maintenance and capital dredging represents a potential risk to tropical environments, especially in turbidity-sensitive environments such as coral reefs. There is little detailed, published observational time-series data that quantifies how dredging affects seawater quality conditions temporally and spatially. This information is needed to test realistic exposure scenarios to better understand the seawater-quality implications of dredging and ultimately to better predict and manage impacts of future projects. Using data from three recent major capital dredging programs in North Western Australia, the extent and duration of natural (baseline) and dredging-related turbidity events are described over periods ranging from hours to weeks. Very close to dredging i.e. <500 m distance, a characteristic features of these particular case studies was high temporal variability. Over several hours suspended sediment concentrations (SSCs) can range from 100-500 mg L-1. Less turbid conditions (10-80 mg L-1) can persist over several days but over longer periods (weeks to months) averages were <10 mg L-1. During turbidity events all benthic light was sometimes extinguished, even in the shallow reefal environment, however a much more common feature was very low light 'caliginous' or daytime twilight periods. Compared to pre-dredging conditions, dredging increased the intensity, duration and frequency of the turbidity events by 10-, 5- and 3-fold respectively (at sites <500 m from dredging). However, when averaged across the entire dredging period of 80-180 weeks, turbidity values only increased by 2-3 fold above pre-dredging levels. Similarly, the upper percentile values (e.g., P99, P95) of seawater quality parameters can be highly elevated over short periods, but converge to values only marginally above baseline states over longer periods. Dredging in these studies altered the overall probability density distribution, increasing the frequency of extreme values. As such, attempts to understand the potential biological impacts must consider impacts across telescoping-time frames and changes to extreme conditions in addition to comparing central tendency (mean/median). An analysis technique to capture the entire range of likely conditions over time-frames from hours to weeks is described using a running means/percentile approach.
Temporal Patterns in Seawater Quality from Dredging in Tropical Environments
Jones, Ross; Fisher, Rebecca; Stark, Clair; Ridd, Peter
2015-01-01
Maintenance and capital dredging represents a potential risk to tropical environments, especially in turbidity-sensitive environments such as coral reefs. There is little detailed, published observational time-series data that quantifies how dredging affects seawater quality conditions temporally and spatially. This information is needed to test realistic exposure scenarios to better understand the seawater-quality implications of dredging and ultimately to better predict and manage impacts of future projects. Using data from three recent major capital dredging programs in North Western Australia, the extent and duration of natural (baseline) and dredging-related turbidity events are described over periods ranging from hours to weeks. Very close to dredging i.e. <500 m distance, a characteristic features of these particular case studies was high temporal variability. Over several hours suspended sediment concentrations (SSCs) can range from 100–500 mg L-1. Less turbid conditions (10–80 mg L-1) can persist over several days but over longer periods (weeks to months) averages were <10 mg L-1. During turbidity events all benthic light was sometimes extinguished, even in the shallow reefal environment, however a much more common feature was very low light ‘caliginous’ or daytime twilight periods. Compared to pre-dredging conditions, dredging increased the intensity, duration and frequency of the turbidity events by 10-, 5- and 3-fold respectively (at sites <500 m from dredging). However, when averaged across the entire dredging period of 80–180 weeks, turbidity values only increased by 2–3 fold above pre-dredging levels. Similarly, the upper percentile values (e.g., P99, P95) of seawater quality parameters can be highly elevated over short periods, but converge to values only marginally above baseline states over longer periods. Dredging in these studies altered the overall probability density distribution, increasing the frequency of extreme values. As such, attempts to understand the potential biological impacts must consider impacts across telescoping-time frames and changes to extreme conditions in addition to comparing central tendency (mean/median). An analysis technique to capture the entire range of likely conditions over time-frames from hours to weeks is described using a running means/percentile approach. PMID:26444284
Goldstein, Michael J; Samstein, Benjamin; Ude, Akuo; Widmann, Warren D; Hardy, Mark A
2005-01-01
A review of surgical residents' duty-hours prompted a Work Hours Assessment and Monitoring Initiative (WHAMI) that preemptively limits residents from violating "duty-hours rules." Work hours data for the Department of Surgery were reviewed over 8-months at New York Presbyterian Hospital-Columbia Campus. This ongoing review is performed by a work-hours monitoring team, which supervises residents' hours for the initial 5-days of each week. As residents approach work-hours limits for the week, they are dismissed from duty for appropriate time periods in the remaining 2 days of the week. The work-hours data entry compliance for 52 residents was increased from 93% to 99% after creation of the WHAMI. Before the new system, a mean of 9.5 residents per month (19%) worked an average of 7.3 +/- 6.4 hours over the 80-hour limit. Averaged monthly compliance with the 80-hour work limit was increased to 98% with introduction of the WHAMI. A review of on-call duty hours revealed a mean of 7 (14%) residents per month who worked an average of 2.4 hours beyond 24-hour call limitations including "sign-out" time imposed by the ACGME. New monitoring procedures have improved compliance to 100% with 24-hour call limitations imposed by the ACGME. Compliance with the more stringent New York State (NYS) guidelines has approached 94% with noncompliant residents extending on-call hours by an average of 1.5 hours over the 24-hour limitations, most on "off General Surgery" rotations or out-of-state rotations. Review of mandatory rest periods contributed to an increase in mean "time off" between work periods, thereby increasing compliance with ACGME guidelines and NYS regulations from 75% to 88%, and 90% to 98%, respectively. Residents reporting less than 10 hours rest reported increased "time off" from 6.2 +/- 2.0 to 7.9 +/- 1.3 hours (p < 0.001). Internal review of surgical resident's duty-hours at a large university hospital revealed that despite strict scheduling and the requirement of mandatory duty-hours entry, achieving the goals of meeting the duty-hours requirements and of ongoing data entry required the creation of a resident enforced, real-time Work Hours Assessment and Monitoring Initiative.
40 CFR Table 1 to Subpart Eeee of... - Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... determiningcompliance using this method 1. Cadmium 18 micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part. 2. Carbon monoxide 40 parts per million by dry volume 3-run average (1 hour minimum sample time per run during performance test), and 12-hour...
40 CFR Table 1 to Subpart Eeee of... - Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... determiningcompliance using this method 1. Cadmium 18 micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part. 2. Carbon monoxide 40 parts per million by dry volume 3-run average (1 hour minimum sample time per run during performance test), and 12-hour...
76 FR 14073 - Agency Information Collection Activities: Existing Collection; Comments Requested
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-15
... year, one year or less; and unsentenced inmates; (b) The number of inmates housed in privately operated... average respondent to respond to both forms: 51 respondents each taking an average 6.5 total hours to respond to the NPS-1B. Burden hours are down by 76 hours since the last clearance because we are...
40 CFR 60.58b - Compliance and performance testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... demonstrated municipal waste combustor unit load shall be the highest 4-hour arithmetic average load achieved... shall be the highest 4-hour arithmetic average temperature achieved at the particulate matter control...
Przylipiak, Andrzej Feliks; Galicka, Elżbieta; Donejko, Magdalena; Niczyporuk, Marek; Przylipiak, Jerzy
2013-01-01
Background Liposuction is a type of aesthetic surgery that has been performed on humans for decades. There is not much literature addressing the subject matter of pre- and post-surgery blood parameters, although this information is rather interesting. Documentation on patients who received laser-assisted liposuction treatment is particularly scarce. Until now, there has been no literature showing values of platelets, lymphocytes, and neutrophils after liposuction. Purpose The aim of the work is to analyze and interpret values of platelets, lymphocytes and neutrophils in patient blood before and after liposuction, a surgery in which an extraordinarily large amount of potent drugs are used. Moreover, the aim is to compare values changes in patients of conventional and laser-assisted liposuction. Material and methods We evaluated standard blood samples in patients prior to and after liposuction. This paper covers the number of platelets, lymphocytes, and neutrophils. A total of 54 patients were examined. Moreover, we compared the change in postoperative values in laser-assisted liposuction patients with the change of values in conventional liposuction patients. A paired two-sided Student’s t-test was used for statistical evaluation. P < 0.005 was acknowledged to be statistically significant. Results Values of platelets were raised both in conventional and in laser-assisted liposuction patients, but this difference was statistically non-significant and levels of platelets were still normal and within the range of blood levels in healthy patients. Values of neutrophils rose by up to 79.49% ± 7.74% standard deviation (SD) and values of lymphocytes dropped by up to 12.68% ± 5.61% SD. The before/after variances of conventional tumescent local anesthesia liposuction and variations in laser-assisted liposuction were similar for all measured parameters; they also showed no statistically significant differences between before and after surgery. The mean value of total operation time without laser-assistance was 3 hours 42 minutes (±57 minutes SD, range 2 hours 50 minutes to 5 hours 10 minutes). Surgeries with laser-assistance were on average 16 minutes shorter with a mean duration of 3 hours 26 minutes (±45 minutes SD, range 2 hours 40 minutes to 4 hours 10 minutes). The difference was not statistically significant (P < 0.06). The mean value of aspirate volume for liposuctions performed without laser support was 2,618 mL (±633.7 SD, range 700 mL to 3,500 mL). Mean aspirate volume for liposuctions with laser assistance was increased by up to 61 mL (2,677 mL ± 499.5 SD, range 1,800 mL to 3,500 mL). The difference was not statistically significant (P < 0.71). Conclusion We conclude that conventional liposuction and laser-assisted liposuction have a similar influence on platelets, lymphocytes, and neutrophils in patients. Moreover, laser-assisted liposuction seems to be less time consuming than conventional liposuction. PMID:24143076
Przylipiak, Andrzej Feliks; Galicka, Elżbieta; Donejko, Magdalena; Niczyporuk, Marek; Przylipiak, Jerzy
2013-01-01
Liposuction is a type of aesthetic surgery that has been performed on humans for decades. There is not much literature addressing the subject matter of pre- and post-surgery blood parameters, although this information is rather interesting. Documentation on patients who received laser-assisted liposuction treatment is particularly scarce. Until now, there has been no literature showing values of platelets, lymphocytes, and neutrophils after liposuction. The aim of the work is to analyze and interpret values of platelets, lymphocytes and neutrophils in patient blood before and after liposuction, a surgery in which an extraordinarily large amount of potent drugs are used. Moreover, the aim is to compare values changes in patients of conventional and laser-assisted liposuction. We evaluated standard blood samples in patients prior to and after liposuction. This paper covers the number of platelets, lymphocytes, and neutrophils. A total of 54 patients were examined. Moreover, we compared the change in postoperative values in laser-assisted liposuction patients with the change of values in conventional liposuction patients. A paired two-sided Student's t-test was used for statistical evaluation. P < 0.005 was acknowledged to be statistically significant. Values of platelets were raised both in conventional and in laser-assisted liposuction patients, but this difference was statistically non-significant and levels of platelets were still normal and within the range of blood levels in healthy patients. Values of neutrophils rose by up to 79.49% ± 7.74% standard deviation (SD) and values of lymphocytes dropped by up to 12.68% ± 5.61% SD. The before/after variances of conventional tumescent local anesthesia liposuction and variations in laser-assisted liposuction were similar for all measured parameters; they also showed no statistically significant differences between before and after surgery. The mean value of total operation time without laser-assistance was 3 hours 42 minutes (± 57 minutes SD, range 2 hours 50 minutes to 5 hours 10 minutes). Surgeries with laser-assistance were on average 16 minutes shorter with a mean duration of 3 hours 26 minutes (± 45 minutes SD, range 2 hours 40 minutes to 4 hours 10 minutes). The difference was not statistically significant (P < 0.06). The mean value of aspirate volume for liposuctions performed without laser support was 2,618 mL (± 633.7 SD, range 700 mL to 3,500 mL). Mean aspirate volume for liposuctions with laser assistance was increased by up to 61 mL (2,677 mL ± 499.5 SD, range 1,800 mL to 3,500 mL). The difference was not statistically significant (P < 0.71). We conclude that conventional liposuction and laser-assisted liposuction have a similar influence on platelets, lymphocytes, and neutrophils in patients. Moreover, laser-assisted liposuction seems to be less time consuming than conventional liposuction.
Measurements of fine and ultrafine particles formation in photocopy centers in Taiwan
NASA Astrophysics Data System (ADS)
Lee, Chia-Wei; Hsu, Der-Jen
This study investigates the levels of particulate matter smaller than 2.5 μm (PM 2.5) and some selected volatile organic compounds (VOCs) at 12 photocopy centers in Taiwan from November 2004 to June 2005. The results of BTEXS (benzene, toluene, ethylbenzene, xylenes and styrene) measurements indicated that toluene had the highest concentration in all photocopy centers, while the concentration of the other four compounds varied among the 12 photocopy centers. The average background-corrected eight-hour PM 2.5 in the 12 photocopy centers ranged from 10 to 83 μg m -3 with an average of 40 μg m -3. The 24-h indoor PM 2.5 at the photocopy centers was estimated and at two photocopy centers exceeded 100 μg m -3, the 24-h indoor PM 2.5 guideline recommended by the Taiwan EPA. The ozone level and particle size distribution at another photocopy center were monitored and indicated that the ozone level increased when the photocopying started and the average ozone level at some photocopy centers during business hour may exceed the value (50 ppb) recommended by the Taiwan EPA. The particle size distribution monitored during photocopying indicated that the emitted particles were much smaller than the original toner powders. Additionally, the number concentration of particles that were smaller than 0.5 μm was found to increase during the first hour of photocopying and it increased as the particle size decreased. The ultrafine particle (UFP, <100 nm) dominated the number concentration and the peak concentration appeared at sizes of under 50 nm. A high number concentration of UFP was found with a peak value of 1E+8 particles cm -3 during photocopying. The decline of UFP concentration was observed after the first hour and the decline is likely attributable to the surface deposition of charged particles, which are charged primarily by the diffusion charging of corona devices in the photocopier. This study concludes that ozone and UFP concentrations in photocopy centers should be concerned in view of indoor air quality and human health. The corona devices in photocopiers and photocopier-emitted VOCs have the potential to initiate indoor air chemistry during photocopying and result in the formation of UFP.
Czabak-Garbacz, Róza; Skibniewska, Agnieszka; Mazurkiewicz, Piotr; Gdula, Agnieszka
2002-01-01
The aim of the study was the assessment of leisure time among third-year students from the Faculty of Pharmacy of the Medical University of Lublin. It analysed quantity of time devoted to school activity and ways of spending free time. The study involved 114 students (82 women and 32 men). The study revealed that women had less free time than men, who, most probably did not attend some lectures. The most popular activities among the questioned students were: sleeping (average 6.8 hours a day), studying (average 3.6 hours a day), listening to the radio (average 2.9 hours a day), talking with friends (average 1.9 hours a day), personal hygiene (average 1.1 hours a day), watching TV (average 1.1 hours a day), housework. Students devoted the least of their free time on active rest, for example walking (women did it more often than men) or practising sport (more popular among men). Cultural life of the students consisted only of meetings with friends and going to the cinema (women did it more often). The least popular way of spending free time was going to the theatre, opera, concerts and exhibitions. Few students spent their time working. Their number increased significantly during holidays. The way of spending free time by third-year students from the Faculty of Pharmacy (both men and women) during the day was similar, differences related only to the amount of time devoted to each activity.
An interplanetary magnetic field ensemble at 1 AU
NASA Technical Reports Server (NTRS)
Matthaeus, W. H.; Goldstein, M. L.; King, J. H.
1985-01-01
A method for calculation ensemble averages from magnetic field data is described. A data set comprising approximately 16 months of nearly continuous ISEE-3 magnetic field data is used in this study. Individual subintervals of this data, ranging from 15 hours to 15.6 days comprise the ensemble. The sole condition for including each subinterval in the averages is the degree to which it represents a weakly time-stationary process. Averages obtained by this method are appropriate for a turbulence description of the interplanetary medium. The ensemble average correlation length obtained from all subintervals is found to be 4.9 x 10 to the 11th cm. The average value of the variances of the magnetic field components are in the approximate ratio 8:9:10, where the third component is the local mean field direction. The correlation lengths and variances are found to have a systematic variation with subinterval duration, reflecting the important role of low-frequency fluctuations in the interplanetary medium.
40 CFR 62.14455 - What if my HMIWI goes outside of a parameter limit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature (3-hour rolling average) simultaneously The PM, CO, and dioxin/furan emission limits. (c) Except..., daily average for batch HMIWI), and below the minimum dioxin/furan sorbent flow rate (3-hour rolling average) simultaneously The dioxin/furan emission limit. (3) Operates above the maximum charge rate (3...
Relationship between road traffic accidents and conflicts recorded by drive recorders.
Lu, Guangquan; Cheng, Bo; Kuzumaki, Seigo; Mei, Bingsong
2011-08-01
Road traffic conflicts can be used to estimate the probability of accident occurrence, assess road safety, or evaluate road safety programs if the relationship between road traffic accidents and conflicts is known. To this end, we propose a model for the relationship between road traffic accidents and conflicts recorded by drive recorders (DRs). DRs were installed in 50 cars in Beijing to collect records of traffic conflicts. Data containing 1366 conflicts were collected in 193 days. The hourly distributions of conflicts and accidents were used to model the relationship between accidents and conflicts. To eliminate time series and base number effects, we defined and used 2 parameters: average annual number of accidents per 10,000 vehicles per hour and average number of conflicts per 10,000 vehicles per hour. A model was developed to describe the relationship between the two parameters. If A(i) = average annual number of accidents per 10,000 vehicles per hour at hour i, and E(i) = average number of conflicts per 10,000 vehicles per hour at hour i, the relationship can be expressed as [Formula in text] (α>0, β>0). The average number of traffic accidents increases as the number of conflicts rises, but the rate of increase decelerates as the number of conflicts increases further. The proposed model can describe the relationship between road traffic accidents and conflicts in a simple manner. According to our analysis, the model fits the present data.
Guest, C S; Morgan, P; Moss, J R; Woodward, A J; McMichael, A J
1996-06-01
The National Health and Medical Research Council's air quality goal for ozone in the troposphere (near the earth's surface) is 0.12 parts per million (ppm), averaged over one hour, similar to the United States standard, but less stringent than the guideline for Europe. We aimed to identify the environmental, economic and social changes that would be associated with changing the goal. Methods included literature review, economic assessments and group interviews. The group to benefit from lower exposures may include outdoor workers, school children and people not in regular day-time work indoors, because ozone is most prevalent during the daylight hours of the warmer months. A lower level could improve the yield of some crops. The causes and effects of tropospheric ozone are not appreciated except among groups with relevant commercial, industrial or scientific experience. However, the consultations identified frustration about the social problems caused by dependence on private motor vehicles. Short-term costs of compliance with a more stringent goal would fall principally on the users of transport. The value of the benefits was enough for many to support making the ozone goal more stringent, but those who required a demonstration of financial benefit (even including savings of health care costs) did not support any change to the goal. Based primarily on averted detriment to health, we recommend the more stringent level of 0.08 ppm (one-hour average) as the goal for the year 2005 in Australia and elsewhere. The addition of a goal with longer averaging time is also proposed.
Landers, Merrill R; McWhorter, James W; Krum, Laura L; Glovinsky, David
2005-09-01
Although formal continuing education (CE) in physical therapy is one part of professional development, its value for renewing licensure is not shared by all states. The purpose of this study was to explore the differences in how physical therapists pursue formal continuing education on the basis of state mandate, sex, years of experience, practice specialty, American Physical Therapy Association membership, motivation, and perception of the benefits of CE. A survey questionnaire was sent to 3,000 physical therapists in 7 states--1,500 to physical therapists in states with mandatory CE and 1,500 to physical therapists in states without a requirement. A total of 1,145 usable survey questionnaires were returned, for a response rate of 38.2%. Physical therapists in states with mandatory CE averaged 33.8 hours of CE per year, whereas physical therapists in states without a mandate averaged 28.3 hours per year; 5.9% of therapists in states without a mandate reported taking no CE at all, and 10.8% reported taking 2 or fewer hours of CE within the preceding 5 years. No statistically significant relationships were observed between the amount of CE taken and years of experience, sex, or practice specialty. Therapists who reported membership in the American Physical Therapy Association participated in 7.2 more hours of CE per year than therapists who did not report membership. Significant motivational variables that respondents noted for taking CE were state mandate, increased clinical competence, and certification. Therapists overwhelmingly (96.2%) believed that CE had a beneficial effect on their clinical practice. Results from this study suggest that mandatory CE does have a significant association with the number of formal CE hours taken by physical therapists.
Song, Yilin; Yang, Huixia
2014-08-01
To compare the clinical use of continuous glucose monitoring system (CGMS) and self-monitoring blood glucose (SMBG) when monitoring blood glucose level of patients with gestational diabetes mellitus (GDM) or type 2 diabetes mellitus (DM) complicated with pregnancy. A total of 99 patients with GDM (n = 70) and type 2 DM complicated with pregnancy (n = 29) that whether hospitalized or in clinical of Peking University First Hospital were recruited from Aug 2012 to Apr 2013. The CGMS was used to monitor their blood glucose level during the 72-hour time period, while the SMBG was also taken seven times daily. The correlation between these blood glucose levels and their glycosylated hemoglobin (HbA1c) levels were analyzed by comparing the average value, the maximum and the minimum value of blood glucose, and the appeared time of these extremum values in these two monitoring methods, and the amount of insulin usage was recorded as well. (1) The maximum, minimum and the average blood glucose value in the GDM group were (8.7 ± 1.2), (4.5 ± 0.6)and (6.3 ± 0.6)mmol/L of SMBG vs. (10.1 ± 1.7), (3.1 ± 0.7), (6.0 ± 0.6) mmol/L of CGMS. These values in DM group were(10.1 ± 2.2), (4.5 ± 1.0), (6.9 ± 1.1)mmol/L of SMBG vs.(12.2 ± 2.6), (2.8 ± 0.8), (6.6 ± 1.1) mmol/L of CGMS. By using the two methods, the maximum and the average value of the two groups showed significant differences (P < 0.01) while the minimum value showed no significant differences (P > 0.05). (2) In the GDM group, the average blood glucose values of CGMS and SMBG were significantly correlated (r = 0.864, P < 0.01). The maximum values presented the same result (r = 0.734, P < 0.01). Correlation was not found in the minimum values of CGMS and SMBG (r = 0.138, P > 0.05). In the DM group, the average valves of two methods were significantly correlated (r = 0.962, P < 0.01), the maximum values showed the same result (r = 0.831, P < 0.01).It can also be observed in the minimum values (r = 0.460, P < 0.05). (3) There was significant correlation between the average value of CGMS and HbA1c level (r = 0.400, P < 0.01), and the average value of SMBG and HbA1c level were correlated (r = 0.031, P < 0.05) in the GDM group; the average values of CGMS (r = 0.695, P < 0.01) and SMBG (r = 0.673, P < 0.01) were both significantly correlated with the HbA1c level in the DM group. (4) In the GDM group, 37% (26/70) of the minimum values of SMBG appeared 30 minutes before breakfast, while 34% (24/70) of them appeared 30 minutes before lunch; 86% (60/70) of the maximum values of SMBG were evenly distributed 2 hours after each of the three meals. In the DM group, 41% (12/29) of the minimum values of SMBG presented 30 minutes before lunch, while 21% (6/29) and 14% (4/29) of them were showed 30 minutes before breakfast and dinner respectively; about 30% of the maximum values of SMBG appeared 2 hours after each of the three meals. (5) In the GDM group, 23% (16/70) of the minimum values of CGMS occurred between 0:00-2:59 am., and most of the other minimum values of CGMS were evenly distributed in the rest of the day, except for 3% (2/70) of them were found during 18:00- 20:59 pm. 43% (30/70) of the maximum values of CGMS appeared during 6:00-8:59 am., only 1% (1/70) and 3% (2/70) of them presented during 0:00-2:59 am. and 21:00-23:59 pm., and the rest were evenly distributed for the other times of the day. In the DM group, 34% (10/29) of the minimum values of CGMS were found during 0:00-2:59 am., 14% (4/29) of them appeared during 9:00-11:59 am. and 15:00-17:59 pm., 45% (13/29) of the maximum values of the CGMS presented during 6:00-8:59 am., none was found during 21:00-23:59 pm.,0:00-2:59 am. and 3:00-5:59 am., and the rest were evenly distributed for the other times of the day. (6) 64% (45/70) of the patients in the GDM group did not require for insulin treatment, while 36% (25/70) of them did. For those patients who received insulin treatment, after CGMS, 64% (16/25) of them adjusted the insulin dosage according to their blood glucose levels. In the DM group, 14% (4/29) of them did not receive insulin treatment, while for the others who did (86%, 25/29); 60% (15/25) of them adjusted the insulin dosage according to their blood glucose levels after CGMS. Both CGMS and SMBG could correctly reflect patients' blood glucose levels. It was more difficult to control the blood glucose levels in patients with type 2 DM complicated with pregnancy than the GDM patients. Compared with SMBG, CGMS could detect postprandial hyperglycemia and nocturnal hypoglycemia more effectively.
Reliability of Multilayer Copper/Polyimide
1993-11-01
LOIS H. WALSH R eliability R esearch E ng ineer -, . .....................-------- - - Reliability Physics Branch i-1’ , ý, Ay cci~i• es "AL f, , or Dist...average of 925 hours The chamber "as operated at 85 C 10 r h All the samples showed initial dielectric constant values consistent w%,ith previous...19. Matsumoto, 0., Katagiri, T., Thin Solid Films, 146, 283 (1987) 20. Malladi , D.P., J Membrane Sci., 19, 209 (1984) 21. Schubert, P.J., Nevin, J.H
Automated drug dispensing systems in the intensive care unit: a financial analysis.
Chapuis, Claire; Bedouch, Pierrick; Detavernier, Maxime; Durand, Michel; Francony, Gilles; Lavagne, Pierre; Foroni, Luc; Albaladejo, Pierre; Allenet, Benoit; Payen, Jean-Francois
2015-09-09
To evaluate the economic impact of automated-drug dispensing systems (ADS) in surgical intensive care units (ICUs). A financial analysis was conducted in three adult ICUs of one university hospital, where ADS were implemented, one in each unit, to replace the traditional floor stock system. Costs were estimated before and after implementation of the ADS on the basis of floor stock inventories, expired drugs, and time spent by nurses and pharmacy technicians on medication-related work activities. A financial analysis was conducted that included operating cash flows, investment cash flows, global cash flow and net present value. After ADS implementation, nurses spent less time on medication-related activities with an average of 14.7 hours saved per day/33 beds. Pharmacy technicians spent more time on floor-stock activities with an average of 3.5 additional hours per day across the three ICUs. The cost of drug storage was reduced by €44,298 and the cost of expired drugs was reduced by €14,772 per year across the three ICUs. Five years after the initial investment, the global cash flow was €148,229 and the net present value of the project was positive by €510,404. The financial modeling of the ADS implementation in three ICUs showed a high return on investment for the hospital. Medication-related costs and nursing time dedicated to medications are reduced with ADS.
Chapman, Teresa; Chew, Felix S
2013-03-01
A lecture series aimed at providing new radiology residents a rapid course on the fundamental concepts of professionalism, safety, and interpretation of diagnostic imaging was established. Evaluation of the course's educational value was attempted through surveys. Twenty-six live 45-minute lectures presented by 16 or 17 faculty members were organized exclusively for the first class of radiology residents, held over a 2-month period at the beginning of certain weekdays. Online surveys were conducted after the course to gather feedback from residents. Average resident rotation evaluation scores were measured over the first semester for the two classes before and after this new course implementation. The lecture series was successfully organized and implemented. A total of 33 residents sat through the course over three summers. Faculty reported a reasonable number of preparation hours, and 100% of residents indicated they valued the course. Comparison of class average evaluation scores before and after the existence of this 2-month course did not significantly change. This collection of introductory lectures on professionalism, safety, and diagnostic imaging, delivered early in the first year of the radiology residency, requires a reasonable number of invested preparation hours by the faculty but results in a universal increase in resident confidence. However, we were unable to demonstrate an objective improvement in resident performance on clinical rotations. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
50 CFR 218.120 - Specified activity and geographical area.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the following mid-frequency active sonar (MFAS) sources, high-frequency active sonar (HFAS) sources...-mounted active sonar)—up to 2,890 hours over the course of 5 years (an average of 578 hours per year); (ii) AN/SQS-56 (hull-mounted active sonar)—up to 260 hours over the course of 5 years (an average of 52...
50 CFR 218.120 - Specified activity and geographical area.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the following mid-frequency active sonar (MFAS) sources, high-frequency active sonar (HFAS) sources...-mounted active sonar)—up to 2,890 hours over the course of 5 years (an average of 578 hours per year); (ii) AN/SQS-56 (hull-mounted active sonar)—up to 260 hours over the course of 5 years (an average of 52...
50 CFR 218.120 - Specified activity and geographical area.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the following mid-frequency active sonar (MFAS) sources, high-frequency active sonar (HFAS) sources...-mounted active sonar)—up to 2,890 hours over the course of 5 years (an average of 578 hours per year); (ii) AN/SQS-56 (hull-mounted active sonar)—up to 260 hours over the course of 5 years (an average of 52...
50 CFR 218.120 - Specified activity and geographical area.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the following mid-frequency active sonar (MFAS) sources, high-frequency active sonar (HFAS) sources...-mounted active sonar)—up to 2,890 hours over the course of 5 years (an average of 578 hours per year); (ii) AN/SQS-56 (hull-mounted active sonar)—up to 260 hours over the course of 5 years (an average of 52...
40 CFR Table 2 to Subpart Dddd of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2012 CFR
2012-07-01
... part) Hydrogen chloride 62 parts per million by dry volume 3-run average (1 hour minimum sample time...) Sulfur dioxide 20 parts per million by dry volume 3-run average (1 hour minimum sample time per run...-8) or ASTM D6784-02 (Reapproved 2008).c Opacity 10 percent Three 1-hour blocks consisting of ten 6...
Childress, Ann; Berry, Sally A.; Belden, Heidi; Walters, Faith; Chappell, Phillip; Sherman, Nancy; Orazem, John; Palumbo, Donna
2017-01-01
Abstract Objective: This phase 3, laboratory classroom study assessed the efficacy and safety of methylphenidate hydrochloride extended-release chewable tablets (MPH ERCT) compared with placebo in children with attention-deficit/hyperactivity disorder (ADHD). Methods: Following a 6-week, open-label, dose-optimization period, children 6–12 years of age (n = 90) with ADHD were randomly assigned to double-blind MPH ERCT at the final optimized dose (20–60 mg/day) or placebo. After 1 week of double-blind treatment, efficacy was assessed predose and 0.75, 2, 4, 8, 10, 12, and 13 hours postdose in a laboratory classroom setting. The primary efficacy measure was the average of postdose Swanson, Kotkin, Agler, M-Flynn, and Pelham (SKAMP) Rating Scale-Combined scores, analyzed using a mixed-model, repeated-measures analysis. Secondary efficacy measures included Permanent Product Measure of Performance (PERMP) total number of problems attempted and total number of problems correct. Safety assessments included adverse event (AE) monitoring and the Columbia-Suicide Severity Rating Scale (C-SSRS). Results: MPH ERCT treatment statistically significantly reduced the average of all postdose SKAMP-Combined scores versus placebo (least-squares mean difference [95% confidence interval], −7.0 [−10.9, −3.1]; p < 0.001). Statistically significant treatment differences in SKAMP-Combined scores were observed at 2 hours postdose through 8 hours postdose (p-values <0.001). Statistically significant differences between MPH ERCT and placebo in PERMP total number of problems attempted and total number of problems correct were observed at 0.75 hours postdose through 8 hours postdose (p-values ≤0.049). Common AEs in the open-label period (≥5%) were decreased appetite, upper abdominal pain, mood swings, irritability, insomnia, upper respiratory tract infection (URTI), dysgeusia, and headache; URTI was the only AE reported by >1 subject receiving MPH ERCT in the double-blind period (placebo: URTI, contusion, wound, and initial insomnia). No suicidal ideation or behavior was reported on the C-SSRS at baseline or at any postbaseline assessment. Conclusions: MPH ERCT 20–60 mg significantly improved ADHD symptoms compared with placebo at 2 hours postdose through at least 8 hours postdose. MPH ERCT was generally safe and well tolerated, with a safety profile consistent with other MPH ER formulations. ClinicalTrials.gov Identifier: NCT01654250. www.clinicaltrials.gov/ct2/show/NCT01654250. PMID:28557548
Effect of mannitol on globe and orbital volumes in humans.
Weber, Adam C; Blandford, Alexander D; Costin, Bryan R; Perry, Julian D
2018-03-01
To determine the effect of intravenous mannitol on globe and orbital volumes. Retrospective chart review of a consecutive series of Cleveland Clinic Neurosurgical Intensive Care Unit patients who underwent computed tomographic imaging before and after intravenous mannitol administration. Volume measurements were performed according to a previously described technique by averaging axial image areas. Measurements before and after mannitol administration were compared using paired t-test. Fourteen patients (28 eyes) met inclusion criteria. Average globe volume decreased 186 mm 3 (-2.5%, p = 0.02) after mannitol administration, while average orbital volume increased 353 mm 3 (+3.5%, p = 0.04). Average globe volume change for subjects with follow-up scan less than 4.7 hours (mean 1.9 hours; range 0.2-4.5 hours) after mannitol administration was -125 mm 3 (-1.7%, p = 0.24) and average orbital volume change was +458 mm 3 (+5.1%, p = 0.11). Average globe volume change after mannitol administration for those with follow-up more than 4.7 hours (average 13.9 hours, range 4.9-24.7 hours) was -246 mm 3 (-3.3%, p = 0.05) and orbital volume change was +248 mm 3 (+2.2%, p = 0.24). Dividing the study population into groups based on mannitol dose did not yield any statistically significant change. Human globe volume decreases after intravenous mannitol administration, while orbital volume increases. These volume changes occur during the time period when intraocular pressure normalizes, after the pressure-lowering effects of the drug. This novel volumetric information improves our understanding of mannitol's mechanism of action and its effects on human ocular and periocular tissues.
Magnetic field hourly averages from the Rome-GSFC experiment aboard Helios 1 and Helio 2
NASA Technical Reports Server (NTRS)
Mariani, F.; Ness, N. F.; Bavassano, B.; Bruno, R.; Buccellato, R.; Burlaga, L. F.; Cantarano, S.; Scearce, C. S.; Terenzi, R.; Villante, U.
1987-01-01
Plots of all the hourly averages computed from the solar magnetic field measurements obtained during the mission are given separately for Helios 1 and Helios 2. The magnitude and the direction of the averaged field are plotted versus the number of solar rotations as seen from Helios, counted from launch.
Pacific Marine Energy Center - South Energy Test Site, Wave Measurements
Annette von Jouanne
2016-06-06
TRIAXYS data from the NNMREC-SETS, for Nov. 2014 - Jan. 2015, and May 2015 - Dec. 2015. The data consists of: Date, Time, significant wave height (1 hour average), significant wave period (1 hour average).
Brvar, Miran; Stajer, Dusan; Kozelj, Gordana; Osredkar, Josko; Mozina, Martin; Bunc, Matjaz
2007-01-01
Altered mental status, autonomic dysfunction, and neuromuscular abnormalities are a characteristic triad of serotonin syndrome. No laboratory tests confirm the diagnosis of serotonin syndrome. A 35-year-old woman took moclobemide, sertraline, and citalopram in a suicide attempt. She was conscious with mild tachycardia, hypertension, and tachypnea one hour after ingestion. In the second hour after ingestion diaphoresis, mydriasis, horizontal nystagmus, trismus, hyperreflexia, clonus, and tremor appeared. She became agitated and unresponsive. In the third hour after ingestion she became comatose and hyperthermic. She was anesthetized, paralyzed, intubated, and ventilated for 24 hours. Serum moclobemide, sertraline, and citalopram levels were above therapeutic levels. The serum serotonin level was within normal limits and the urinary 5-hydroxyindoleacetic acid:creatinine ratio was below the average daily value. The urinary serotonin:creatinine ratio was increased on arrival (1 mg/g). The urinary serotonin level is increased in serotonin syndrome due to a monoamine oxidase inhibitor and selective serotonin-reuptake inhibitors overdose. It is possible that urinary serotonin concentration could be used as a biochemical marker of serotonin syndrome.
NASA Technical Reports Server (NTRS)
Smith, J. H.
1994-01-01
This computer program, SOLINS, was developed to aid engineers and solar system designers in the accurate modeling of the average hourly solar insolation on a surface of arbitrary orientation. The program can be used to study insolation problems specific to residential and commercial applications where the amount of space available for solar collectors is limited by shadowing problems, energy output requirements, and costs. For tandem rack arrays, SOLINS will accommodate the use of augmentation reflectors built into the support structure to increase insolation values at the collector surface. As the use of flat plate solar collectors becomes more prevalent in the building industry, the engineer and designer must have the capability to conduct extensive sensitivity analyses on the orientation and location of solar collectors. SOLINS should prove to be a valuable aid in this area of engineering. SOLINS uses a modified version of the National Bureau of Standards model to calculate the direct, diffuse, and reflected components of total insolation on a tilted surface with a given azimuthal orientation. The model is based on the work of Liu and Jordan with corrections by Kusuda and Ishii to account for early morning and late afternoon errors. The model uses a parametric description of the average day solar climate to generate monthly average day profiles by hour of the insolation level on the collector surface. The model includes accommodation of user specified ground and landscape reflectivities at the collector site. For roof or ground mounted, tilted arrays, SOLINS will calculate insolation including the effects of shadowing and augmentation reflectors. The user provides SOLINS with data describing the array design, array orientation, the month, the solar climate parameter, the ground reflectance, and printout control specifications. For the specified array and environmental conditions, SOLINS outputs the hourly insolation the array will receive during an average day during the month specified, along with the total insolation the collector surface will receive over an average 24-hour period. This program is written in FORTRAN IV for batch execution and has been implemented on an IBM 370 computer with a central memory requirement of approximately 46K of 8 bit bytes. The SOLINS routines were developed in 1979.
Study of air pollution in the Aburra Valley, Colombia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bedoya, J.; Bedoya, E.
1980-01-01
A study of air pollution in the Aburra Valley, Colombia, showed that in 1978, the total vehicular (automobiles, buses, and trucks) fuel consumption, including gasoline, fuel oil, kerosine and aviation gasoline, was 136 million gal, which, based on EPA emission factors, produced 755 metric tons of particulate matter and 245 metric tons of sulfur dioxide. In the city of Medellin, during 1976-1979, sulfur dioxide concentrations averaged 40 jg/cu m annually at two sampling stations representing the worst cases, a value below the Colombian standard of 70 jg/cu m. The annual average for the city showed an increase of 22 jg/cumore » m in 1977 to 30 jg/cu m in 1979. In March 1978, the Olaya Herrera Airport in Aburra Valley was closed a number of hours due to lack of visibility caused by fumes; on 3/17/78, it was closed ten hours. The economic and demographic aspects of the Aburra Valley, industrial sources of pollution in the Valley and Colombian air pollution regulations are discussed.« less
78 FR 68440 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-14
... Use: The ``Report of Premiums Payable for Exporters Only'' form is used by exporters to report and pay... Expenses Reviewing Time per Year: 7,800 hours. Average Wages per Hour: $42.50. Average Cost per Year: $331...
Code of Federal Regulations, 2011 CFR
2011-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4767(a) i. Collecting the combustion temperature data according to § 63.4768(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour block average combustion...
Code of Federal Regulations, 2010 CFR
2010-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4966(a) i. collecting the combustion temperature data according to § 63.4967(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion temperature...
Code of Federal Regulations, 2012 CFR
2012-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4167(a) i. collecting the combustion temperature data according to § 63.4168(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion temperature...
Code of Federal Regulations, 2014 CFR
2014-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4167(a) i. collecting the combustion temperature data according to § 63.4168(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion temperature...
Code of Federal Regulations, 2010 CFR
2010-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4767(a) i. Collecting the combustion temperature data according to § 63.4768(c);ii. Reducing the data to 3-hour block averages; and iii. Maintaining the 3-hour block average combustion...
Code of Federal Regulations, 2013 CFR
2013-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4167(a) i. collecting the combustion temperature data according to § 63.4168(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion temperature...
Code of Federal Regulations, 2011 CFR
2011-07-01
... combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.4966(a) i. collecting the combustion temperature data according to § 63.4967(c);ii. reducing the data to 3-hour block averages; and iii. maintaining the 3-hour average combustion temperature...
5 CFR 550.154 - Rates of premium pay payable under § 550.151.
Code of Federal Regulations, 2010 CFR
2010-01-01
... not more than 9 hours a week or irregular or occasional overtime work—20 percent; (4) A position which requires an average of over 9 hours a week of irregular or occasional overtime work—25 percent. (b) If an... average of at least 3 but not more than 5 hours a week of irregular or occasional overtime work—10 percent...
Start Your Energy Conversion Devices
:37 a.m. and 1:33 p.m. MIT's car took only 1 hour, 37 minutes and 8 seconds to travel the 65 miles at an average speed of 40.60 miles per hour. Closely following was Stanford University/University of California-Berkeley's Afterburner II coming in at 1:37:25, with an average speed of 40.48 miles per hour
Deviney, Frank A.; Rice, Karen C.; Hornberger, George M.
2006-01-01
Acid rain affects headwater streams by temporarily reducing the acid‐neutralizing capacity (ANC) of the water, a process termed episodic acidification. The increase in acidic components in stream water can have deleterious effects on the aquatic biota. Although acidic deposition is uniform across Shenandoah National Park (SNP) in north central Virginia, the stream water quality response during rain events varies substantially. This response is a function of the catchment's underlying geology and topography. Geologic and topographic data for SNP's 231 catchments are readily available; however, long‐term measurements (tens of years) of ANC and accompanying discharge are not and would be prohibitively expensive to collect. Transfer function time series models were developed to predict hourly ANC from discharge for five SNP catchments with long‐term water‐quality and discharge records. Hourly ANC predictions over short time periods (≤1 week) were averaged, and distributions of the recurrence intervals of annual water‐year minimum ANC values were model‐simulated for periods of 6, 24, 72, and 168 hours. The distributions were extrapolated to the rest of the SNP catchments on the basis of catchment geology and topography. On the basis of the models, large numbers of SNP streams have 6‐ to 168‐hour periods of low‐ANC values, which may stress resident fish populations. Smaller catchments are more vulnerable to episodic acidification than larger catchments underlain by the same bedrock. Catchments with similar topography and size are more vulnerable if underlain by less basaltic/carbonate bedrock. Many catchments are predicted to have successive years of low‐ANC values potentially sufficient to extirpate some species.
Linear time series modeling of GPS-derived TEC observations over the Indo-Thailand region
NASA Astrophysics Data System (ADS)
Suraj, Puram Sai; Kumar Dabbakuti, J. R. K.; Chowdhary, V. Rajesh; Tripathi, Nitin K.; Ratnam, D. Venkata
2017-12-01
This paper proposes a linear time series model to represent the climatology of the ionosphere and to investigate the characteristics of hourly averaged total electron content (TEC). The GPS-TEC observation data at the Bengaluru international global navigation satellite system (GNSS) service (IGS) station (geographic 13.02°N , 77.57°E ; geomagnetic latitude 4.4°N ) have been utilized for processing the TEC data during an extended period (2009-2016) in the 24{th} solar cycle. Solar flux F10.7p index, geomagnetic Ap index, and periodic oscillation factors have been considered to construct a linear TEC model. It is evident from the results that solar activity effect on TEC is high. It reaches the maximum value (˜ 40 TECU) during the high solar activity (HSA) year (2014) and minimum value (˜ 15 TECU) during the low solar activity (LSA) year (2009). The larger magnitudes of semiannual variations are observed during the HSA periods. The geomagnetic effect on TEC is relatively low, with the highest being ˜ 4 TECU (March 2015). The magnitude of periodic variations can be seen more significantly during HSA periods (2013-2015) and less during LSA periods (2009-2011). The correlation coefficient of 0.89 between the observations and model-based estimations has been found. The RMSE between the observed TEC and model TEC values is 4.0 TECU (linear model) and 4.21 TECU (IRI2016 Model). Further, the linear TEC model has been validated at different latitudes over the northern low-latitude region. The solar component (F10.7p index) value decreases with an increase in latitude. The magnitudes of the periodic component become less significant with the increase in latitude. The influence of geomagnetic component becomes less significant at Lucknow GNSS station (26.76°N, 80.88°E) when compared to other GNSS stations. The hourly averaged TEC values have been considered and ionospheric features are well recovered with linear TEC model.
NASA Technical Reports Server (NTRS)
1974-01-01
The standard plate cells exhibited higher average end-of-charge (EOC) voltages than the cells with teflonated negative plates; they also delivered a higher capacity output in ampere hours following these charges. All the cells reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test. The average ampere hours in and voltages at this pressure were 33.6 and 1.505 volts respectively for the teflonated negative plate cells and 35.5 and 1.523 volts for the standard plate cells. All cells exhibited pressure decay in the range of 1 to 7 psia during the last 30 minutes of the 1-hour open circuit stand. Average capacity out for the teflonated and standard negative plate cells was 29.4 and 29.9 ampere hours respectively.
The air quality analysis of Dalian based on the data of AQI
NASA Astrophysics Data System (ADS)
Gu, Ji-lin; Liu, Miao
2018-02-01
The data of AQI from 10 countries accused of automatic air quality monitoring station of Dalian from June 2015 to December 2016 were analyzed to investigate the daily mean change of air quality index, the change of the hour and the correlation analysis between AQI and PM2.5, PM10, SO2, NO2, CO, O3 six parameters. The 856,800 index samples showed that the air quality index of autumn and winter was obviously higher than that of summer. The maximum AQI value in autumn and winter reached 389, with an average of 82. The maximum value of AQI in summer was 130, and the average was 50. From 2015 to 2016, the excellent air quality in the summer in Dalian was 60.3%; the standard rate was 98.4%. The autumn and winter air quality accounted for 39.1% and the compliance rate was 68.5%. The mean of the AQI average daily was a wavy trend, and the changes of summer and autumn and winter were roughly the same. The regularity of AQI 24-hour showed multi-peak changes, bimodal changes and single peak changes. The air quality in Dalian is affected by the weather conditions such as wind direction, rainfall and fog, the air quality in surrounding cities, urban pollution, vehicle exhaust and excessive consumption of coal energy. Through correlation calculation, AQI, PM2.5, and PM10 were significantly correlated irrespective of season. AQI and O3 were positively correlated in summer, but negatively correlated in autumn and winter, which is the basis for the treatment of air pollution in Dalian.
Particulate sulphate and ozone in rural air: Preliminary results from three sites in central England
NASA Astrophysics Data System (ADS)
Martin, A.; Barber, F. R.
Daily particulate sulphate concentrations in air have been measured at a 'background' rural site and at two other sites near rural power stations. The samples were collected by drawing air through filter papers and were analysed by X-ray fluorescence. At the background site the concentration of particulate sulphates was strongly dependent on the O 3 and total S in air. Above a certain 'critical' level of daily O 3, 28% of the daily S in air was particulate on average, but the amounts were not related to the actual O 3 levels. At lower O 3 levels, there appeared to be a constant background of about 2 μg of particulate sulphate per cubic meter of air, together with about 5% of the total S in air as particulate. When black smoke in air was low, the particulate sulphate was also low, despite the O 3 levels. Near the power stations, there was no significantly different rate of production or loss of particulate sulphate. On average, at all three sites over the year, about 12% of the daily total S was particulate, probably corresponding to an average conversion rate of SO 2 of less than 1% per hour. Estimates of hourly particulate sulphates are available from previous measurements at the background site, using a different analysis technique. Particulate sulphate was not found every hour, but typically during 20 h a day in early summer and 8 h a day in early winter. An influence of humidity as well as O 3 was apparent in the peak hourly particulate sulphate values, which reached 60% of the total S. No correlation could be found of particulate sulphate with solar radiation, wind direction, concentrations of oxides of nitrogen in air or ammonium or sulphate in rainwater, but further measurements are planned.
NASA Astrophysics Data System (ADS)
Wang, Yang; Zhao, Chuanfeng
2016-04-01
Clouds play essential roles in the Earth's energy and water cycle, and Cloud Fraction (CF) is one of the most important cloud parameters. The CF from Moderate Resolution Imaging Spectroradiometer (MODIS) has been widely used, whereas the time representation of these instantaneous CF values is not clear. In this study, we evaluate MODIS-derived CF by using continuous, day-and-night radar/lidar CF from the Atmospheric Radiation Measurement (ARM) program Active Remote Sensing of CLouds (ARSCL) product and the total sky cover (TSC) day-time CF datasets. Inter-comparisons between MODIS and surface CFs for time period from 2000 to 2011 are performed for three climate regimes as represented by the ARM sites of Southern Great Plains (SGP), Manus, Papua New Guinea (PNG) and North Slope of Alaska (NSA). We first choose both the TSC and ARSCL CFs averaged over 1 hour around the two passing time of satellite, which are around 10:30 AM and 1:30 PM local time. Then two kind of analyses have been done. One is the spatial variation analysis and the other is temporal variation analysis. For the spatial variation analysis, we compare the 1-hour averaged cloud fractions from TSC and ARSCL around 10:30 AM and 1:30 PM with the instantaneous cloud fractions from MODIS but with different spatial resolution. By obtaining the RMS errors and ratio of average values of CFs for these inter-comparisons, the optimal CF-matching spatial resolutions for MODIS regarding to TSC and ARSCL are obtained which are both 30 km radius of circle. We also find that the optimal matching spatial resolution increases when the ground observation average time increases. For the temporal analysis, we first analyze the diurnal variation of the cloud fraction based on the surface CFs from TSC and ARSCL from which we can see the daily representation of cloud fraction observed at 10:30 AM and 1:30 PM. Then we make a statistical comparison of daily and monthly cloud fraction between using all time observation and using the 1-hour averaged observations at both 10:30 AM and 1:30 PM. Comparison results will be shown in our paper. It shows a high correlation coefficient of 0.95 (0.93) for observations from TSC (ARSCL). The ratios of daily (monthly) averaged cloud fraction between using all time and using the time satellite passes are 0.87(0.92) and 0.86(0.97) for TSC and ARSCL, respectively. This suggests that considerable errors could be introduced while using the cloud fraction at two fixed time points (10:30 AM and 1:30 PM) to represent the daily cloud fraction.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-21
... per day (MGD) or more. Section 316(b) of the Clean Water Act (CWA) requires that any standard... of the rule is estimated to average 1,101 hours per respondent (i.e., an annual average of 46,228 hours of burden divided among an anticipated 42 States on average per year). Burden means the total time...
Code of Federal Regulations, 2011 CFR
2011-07-01
... kilns equipped with WS i. Collecting the scrubber pressure drop data according to § 63.8450(a); reducing the scrubber pressure drop data to 3-hour block averages according to § 63.8450(a); maintaining the average scrubber pressure drop for each 3-hour block period at or above the average pressure drop...
Ten years of measured UV Index from the Spanish UVB Radiometric Network.
Utrillas, M P; Marín, M J; Esteve, A R; Estellés, V; Gandía, S; Núnez, J A; Martínez-Lozano, J A
2013-08-05
An analysis is made of the UV Index (UVI) obtained from the ultraviolet erythemal solar radiation (UVER) data measured by the Spanish UVB Radiometric Network between the years 2000 and 2009. Previously, the daily UVI has been evaluated using two different criteria: (a) the value corresponding to solar noon; and (b) the daily maximum value. The mean percentage of agreement is 92% if we consider the cases for which the difference is zero or one UVI unit. These results are similar to those obtained in a previous work where only 2 years were analyzed. In all the stations the UVI reaches very high values (8-10) in spring-summer, and the very high and extreme (≥ 11) UVI values are more dependent on the continental effect than on the latitude effect. From the UVI values it is possible to classify the stations into four groups: Coastal stations, Continental stations (more than 200 km from the coast), Southern stations (Coastal stations but with similar values of UVI as the Continental ones due to their low latitude) and Canary Islands stations (1400 km southwest from the Iberian Peninsula thus lower latitude). The monthly mean maximum of UVI is reached in July due to the annual evolution of the total ozone column. This value corresponds, for a skin phototype II, to three times the minimal erythemal dose (MED) in an hour in a Coastal station, 3.5 MEDs in an hour measured in a Continental or Southern station and up five MEDs in an hour in the Izaña station (Canary Islands). The cumulative dose on a horizontal plane over an average year has been calculated for each station. More than 40% of the annual dose is received in summer, about 35% in spring, more than 11% in autumn and less than 10% in winter except for the stations in the Canary Islands where the difference between seasons is less significant. Copyright © 2013 Elsevier B.V. All rights reserved.
40 CFR Table 3 to Subpart Dddd of... - Work Practice Requirements
Code of Federal Regulations, 2014 CFR
2014-07-01
... Process furnish with a 24-hour block average inlet moisture content of less than or equal to 30 percent... 24-hour block average inlet moisture content of the veneer is less than or equal to 25 percent (by...
Power Recycled Weak Value Based Metrology
2015-04-29
PAGE The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...cavity, one is able to more efficiently use the input laser power by increasing the total power inside the interferometer. In the context of these weak...EV I EW LE T T ER S week ending 1 MAY 2015 0031-9007=15=114(17)=170801(5) 170801-1 © 2015 American Physical Society We consider a continuous wave laser
2017-09-01
environment outcome. The value is site specific. It may depend on the travel time of groundwater from a source to a property boundary, sentry well...for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data...47 Figure 4.3.4. Decline in Concentrations of PCE, TCE, and cDCE + t-DCE Over Time in Well
NASA Astrophysics Data System (ADS)
Yang, Chao; Wu, Wei; Wu, Shu-Cheng; Liu, Hong-Bin; Peng, Qing
2014-02-01
Aroma types of flue-cured tobacco (FCT) are classified into light, medium, and heavy in China. However, the spatial distribution of FCT aroma types and the relationships among aroma types, chemical parameters, and climatic variables were still unknown at national scale. In the current study, multi-year averaged chemical parameters (total sugars, reducing sugars, nicotine, total nitrogen, chloride, and K2O) of FCT samples with grade of C3F and climatic variables (mean, minimum and maximum temperatures, rainfall, relative humidity, and sunshine hours) during the growth periods were collected from main planting areas across China. Significant relationships were found between chemical parameters and climatic variables ( p < 0.05). A spatial distribution map of FCT aroma types were produced using support vector machine algorithms and chemical parameters. Significant differences in chemical parameters and climatic variables were observed among the three aroma types based on one-way analysis of variance ( p < 0.05). Areas with light aroma type had significantly lower values of mean, maximum, and minimum temperatures than regions with medium and heavy aroma types ( p < 0.05). Areas with heavy aroma type had significantly lower values of rainfall and relative humidity and higher values of sunshine hours than regions with light and medium aroma types ( p < 0.05). The output produced by classification and regression trees showed that sunshine hours, rainfall, and maximum temperature were the most important factors affecting FCT aroma types at national scale.
Colton, Katharine; Yang, S; Hu, P F; Chen, H H; Bonds, B; Stansbury, L G; Scalea, T M; Stein, D M
2016-05-01
Past work has shown the importance of the "pressure times time dose" (PTD) of intracranial hypertension (intracranial pressure [ICP] > 19 mm Hg) in predicting outcome after severe traumatic brain injury. We used automated data collection to measure the effect of common medications on the duration and dose of intracranial hypertension. Patients >17 years old, admitted and requiring ICP monitoring between 2008 and 2010 at a single, large urban tertiary care facility, were retrospectively enrolled. Timing and dose of ICP-directed therapy were recorded from paper and electronic medical records. The ICP data were collected automatically at 6-second intervals and averaged over 5 minutes. The percentage of time of intracranial hypertension (PTI) and PTD (mm Hg h) were calculated. A total of 98 patients with 664 treatment instances were identified. Baseline PTD ranged from 27 (before administration of propofol and fentanyl) to 150 mm Hg h (before mannitol). A "small" dose of hypertonic saline (HTS; ≤250 mL 3%) reduced PTD by 38% in the first hour and 37% in the second hour and reduced the time with ICP >19 by 38% and 39% after 1 and 2 hours, respectively. A "large" dose of HTS reduced PTD by 40% in the first hour and 63% in the second (PTI reduction of 36% and 50%, respectively). An increased dose of propofol or fentanyl infusion failed to decrease PTD but reduced PTI between 14% (propofol alone) and 30% (combined increase in propofol and fentanyl, after 2 hours). Barbiturates failed to decrease PTD but decreased PTI by 30% up to 2 hours after administration. All reductions reported are significantly changed from baseline, P < .05. Baseline PTD values before drug administration reflects varied patient criticality, with much higher values seen before the use of mannitol or barbiturates. Treatment with HTS reduced PTD and PTI burden significantly more than escalation of sedation or pain management, and this effect remained significant at 2 hours after administration. © The Author(s) 2014.
NASA Technical Reports Server (NTRS)
Wielicki, B. A. (Principal Investigator); Barkstrom, B. R. (Principal Investigator); Charlock, T. P.; Baum, B. A.; Green, R. N.; Minnis, P.; Smith, G. L.; Coakley, J. A.; Randall, D. R.; Lee, R. B., III
1995-01-01
The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and Earth's Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies is outlined. Volume 2 details the techniques used to geolocate and calibrate the CERES scanning radiometer measurements of shortwave and longwave radiance to invert the radiances to top-of-the-atmosphere (TOA) and surface fluxes following the Earth Radiation Budget Experiment (ERBE) approach, and to average the fluxes over various time and spatial scales to produce an ERBE-like product. Spacecraft ephemeris and sensor telemetry are used with calibration coefficients to produce a chronologically ordered data product called bidirectional scan (BDS) radiances. A spatially organized instrument Earth scan product is developed for the cloud-processing subsystem. The ERBE-like inversion subsystem converts BDS radiances to unfiltered instantaneous TOA and surface fluxes. The TOA fluxes are determined by using established ERBE techniques. Hourly TOA fluxes are computed from the instantaneous values by using ERBE methods. Hourly surface fluxes are estimated from TOA fluxes by using simple parameterizations based on recent research. The averaging process produces daily, monthly-hourly, and monthly means of TOA and surface fluxes at various scales. This product provides a continuation of the ERBE record.
Time of travel and dispersion in a selected reach of Roberts Creek, Clayton County, Iowa
Kolpin, D.W.; Kalkhoff, S.J.
1992-01-01
Time of travel was determined by dye tracing, using rhodamine WT as the tracer. One dyeinjection site and three sampling sites were used to measure time of travel. Two dye-tracing tests were conducted at discharges having flow-duration values of 48 and 80 percent. The discharges at the time of the two dye-tracing tests approximated medium- and low-flow conditions. The average stream velocity in the study area was 0.23 foot per second during medium-flow conditions, March 20 to 22,1990, and 0.07 foot per second during low-flow conditions, April 30 to May 12, 1990. The injected dye dispersed in a plume that lasted about 18 hours during medium flow and about 64 hours during low flow at the downstream site.
Wrist activity in a woman: daily, weekly, menstrual, lunar, annual cycles?
Binkley, S
1992-09-01
Wrist activity was monitored continuously for one year in a woman who went about her normal life. The year of data were analyzed for changes and rhythms--daily, weekly, menstrual, lunar, annual. For each day, average motions/5 minutes, activity onset, activity offset, alpha (duration of activity), and acrophase were measured. Periodograms and average daily wave forms were calculated. Well-defined, entrained, daily rest-activity cycles were observed throughout the year with periods close to 24 hours. There was weekend delay (0.7 hours) in onset, weekend decrease in alpha (1.0 hours), and weekend advance of acrophase (0.4 hours). Motions/5 minutes decreased 9%, onsets were 0.3 hours later, and alphas were 0.4 hours shorter on menstrual cycle days 8 through 18 which should have encompassed the time of ovulation. Lunar phase had no effect. Annual changes in onset (1.1 hours), offset (1.2 hours), and acrophase (1.1 hours) were attributed to the 1-hour change between standard and daylight savings time.
Zeiders, Katharine H.; Doane Sampey, Leah D.; Adam, Emma K.
2011-01-01
Purpose To examine how hours of sleep and wake times relate to between-person differences and day-to-day changes in diurnal cortisol rhythms in late adolescents Methods Older adolescents (N = 119) provided six cortisol samples (wakeup, +30min, + 2 hours, +8 hours, + 12 hours, and bedtime) on each of three consecutive days while wearing an actigraph. We examined how average (across 3 days) and day-to-day changes in hours of sleep and wake times related to diurnal cortisol patterns. Results On average, greater hours of sleep related steeper decline in cortisol across the days. Day-to-day analyses revealed that prior night’s hours of sleep predicted steeper diurnal slopes the next day, while greater waking cortisol levels and steeper slopes predicted greater hours of sleep and a later wake time the next day. Conclusions Our results suggest a bidirectional relationship between sleep and HPA axis activity. PMID:21575815
Examination of diurnal temperature range at coterminous U.S. stations during Sept. 8-17, 2001
NASA Astrophysics Data System (ADS)
van Wijngaarden, W. A.
2012-07-01
The tragic events of Sept. 11, 2001 resulted in suspension of commercial flights over North America. It has been suggested that the diurnal temperature range (DTR) increased due to an absence of airplane contrails. This study examined hourly data observed at 288 stations. The average DTR, temperature, maximum/minimum temperature and relative humidity were found for each day in 2001 and compared to the average value occurring during 1975-2005. For the coterminous U.S., the DTR averaged over the period Sept. 11-14, 2001 was about 1°C larger than that found for the 3 days prior and after the flight ban. However, the day-to-day DTR does not correlate well with the flight ban. Plots of the change in DTR throughout North America during Sept. 8-17 show changes consistent with the natural progression of weather systems.
Sleep behaviour in a sample of preschool children in Singapore.
Aishworiya, Ramkumar; Chan, Pofun; Kiing, Jennifer; Chong, Shang Chee; Laino, Armi G; Tay, Stacey Kh
2012-03-01
Sleep problems are common in all ages, but may be particularly acute in urban Singapore. This study aims to describe the sleep behaviour of, and to identify any sleep problems in, preschool children. This was a cross-sectional questionnaire survey of 372 children attending local childcare centers. The questionnaire was based on the Children's Sleep Habits Questionnaire (CSHQ), a validated parent-report sleep screening questionnaire that contains 54 items identifying sleep behaviours in children. A total of 372 (40.0%) children participated. The mean age was 4.1 (SD 1.3) years (range, 2 to 6 years). Average total sleep duration was 10.8 hours (SD 1.1) with average night-time sleep duration of 8.5 hours (SD 0.6) and average nap duration of 1.6 hours (SD 1.0). Co-sleeping was common; 80.9% of children shared a room with someone else. The most common sleep problems were in the domains of sleep resistance and morning behaviour; namely: requiring company to fall asleep (n = 272, 73.1%), being afraid to sleep alone (n = 228, 61.6%) and diffi culty in waking up (n = 165, 44.4%). Among parents, 84.1 % (n = 313) perceived that their child's sleep duration was adequate. The duration of sleep in the Singaporean preschool population sampled is signifi cantly lower than recommended values and that of previously described Caucasian populations. Parental perception of sleep adequacy deviates from current recommendations. Given the clear relation of sleep duration with cognitive functioning, learning, and physical growth, this sleep deprivation should be addressed with parental education and opportunistic screening of sleep in well-child follow-ups.
Patel, Shweta V; Driggers, Rita W; Zahn, Christopher M
2011-01-01
To estimate the effect of work hour restrictions on resident outpatient clinical experience. Schedule templates from academic years 1998-1999 (before work hour restrictions), 2002-2003 (when night float rotation was added in anticipation of work hour restrictions), and 2008-2009 (during work hour restrictions) were compared for outpatient clinic experience before and after work hour restrictions were implemented. Actual clinics on specific rotations and estimated patient encounters per scheduled clinic were considered. Between academic year (AY) 1998-1999 and AY 2008-2009 there was a generalized downward trend in average outpatient encounters for postgraduate year (PGY)-2, PGY-3 and PGY-4 residents (45%, 34% and 36%, respectively). For obstetrics, gynecology and ambulatory rotations, there was a downward trend in average outpatient encounters for each rotation type (61%, 14% and 63%, respectively). The average number of scheduled clinics per week was slightly decreased when comparing AY 1998-1999 to either AY 2002-2003 or AY 2008-2009. Rotation schedules before and after work hour restrictions demonstrated a downward trend in the number of scheduled outpatient encounters. These findings indicate a potential negative impact on preparation for clinical practice.
Long Working Hours in Korea: Based on the 2014 Korean Working Conditions Survey.
Park, Jungsun; Kim, Yangho; Han, Boyoung
2017-12-01
Long working hours adversely affect worker safety and health. In 2004, Korea passed legislation that limited the work week to 40 hours, in an effort to improve quality-of-life and increase business competitiveness. This regulation was implemented in stages, first for large businesses and then for small businesses, from 2004 to 2011. We previously reported that average weekly working hours decreased from 2006 to 2010, based on the Korean Working Conditions Survey. In the present study, we examine whether average weekly working hours continued to decrease in 2014 based on the 2014 Korean Working Conditions Survey. The results show that average weekly working hours among all groups of workers decreased in 2014 relative to previous years; however, self-employed individuals and employers (who are not covered by the new legislation) in the specific service sectors worked > 60 h/wk in 2014. The Korean government should prohibit employees from working excessive hours and should also attempt to achieve social and public consensus regarding work time reduction to improve the safety, health, and quality-of-life of all citizens, including those who are employers and self-employed.
Code of Federal Regulations, 2014 CFR
2014-07-01
... parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test..., appendix A-4). Oxides of nitrogen 388 parts per million by dry volume 3-run average (1 hour minimum sample... (1 hour minimum sample time per run) Performance test (Method 6 or 6c of appendix A of this part) a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test..., appendix A-4). Oxides of nitrogen 388 parts per million by dry volume 3-run average (1 hour minimum sample... (1 hour minimum sample time per run) Performance test (Method 6 or 6c of appendix A of this part) a...
NASA Technical Reports Server (NTRS)
Neumann, H. H.; Den Hartog, G.; King, K. M.; Chipanshi, A. C.
1994-01-01
Measurements of carbon dioxide concentration and flux were made above a raised open bog at Lake Kinosheo in the southern Hudson Bay lowlands during the Northern Wetlands Study (NOWES) experiment in 1990. The flux measurements were made using micrometeorological techniques. They provide the first nondisturbing, larger-scale CO2 flux measurements for this ecosystem and are the first to integrate the exchange over the whole 24 hours of the day. Continuous concentration measurements by infrared gas analyzers (IRGA) and spot flask samples were taken over the period July 1 to July 29. Afternoon CO2 values were only 5 to 7 parts per million by volume (ppmv) lower than measurements over the same period at Canadian background monitoring stations. This suggested that there was little draw-down by local photosynthetic sinks. CO2 fluxes were measured at 8 and 18 m by Bowen ratio and eddy correlation methods, respectively. The methods produced comparable results on averaged data but often diverged considerably on individual half-hour results. Fluxes were small. Daytime values averaged to -0.068 mg/sq m/s by eddy correlation and -0.077 mg/sq m/s by Bowen ratio over the period June 25 to July 28 (negative denotes downward flux), while at night, flux densities were +0.062 mg/sq m/s and +0.085 mg/sq m/s. Integration of the mean diurnal curve gave a net flux of -1.7 g/sq m/d. Comparable data for this type of ecosystem were not found. However, Coyne and Kelley (1975), measuring near Barrow, Alaska, over wet meadow tundra dominated by sedges and grasses, found net fluxes of -7.2 g/sq m/d. Typical net CO2 fluxes from other active temperature ecosystems have been found to be -10 to -20 g/sq m/d (Monteith, 1976). Mean half hourly fluxes were almost constant at +0.06 mg/sq m/s through the nighttime hours. About one half-hour after sunrise the flux reversed direction. Uptake peaked about 0900 eastern daylight time (EDT) and then gradually declined but remained downward until near sunset. The early peak was interpreted to signify that the many plants in the bog experienced water stress during the day as evaporative demand increased and nighttime dew was evaporated.
NASA Astrophysics Data System (ADS)
García, A. R.; Grutter, M. M.; Volkamer, R. M.
2007-05-01
An environmental risk assessment for criteria pollutants and air toxics in Mexico City is presented. The data used in the study were collected by FTIR and DOAS systems during the Mexico City Metropolitan Area field campaign on April 2003 (MCMA2003). The systems were deployed in two different sites: One in downtown (Merced) and the other in the south east (CENICA). Concentrations of criteria pollutants and air toxics were obtained every 5 min and were used to obtain hourly average concentrations and the month average for April. The concentration values were used to estimate the risks of acute and chronic exposure to ambient concentrations using risk measures like hazard index, life cancer probability, life lost expectancy and maximum individual cancer risk. Results revealed that both sites have similar risk values. For acute exposure, criteria pollutants have larger risks than air toxics, but air toxics have larger risks for chronic exposure. Ambient concentrations of benzene showed the largest carcinogenic risk of the measured air toxics.
Armentrout, G.W.; Larson, L.R.
1984-01-01
Time-of-travel and dispersion measurements made during a dye study November 7-8, 1978, are presented for a reach of the North Platte River from Casper, Wyo., to a bridge 2 miles downstream from below the Dave Johnston Power Plant. Rhodamine WT dye was injected into the river at Casper, and the resultant dye cloud was traced by sampling as it moved downstream. Samples were taken in three equal-flow sections of the river 's lateral transect at three sites, then analyzed in a fluorometer. The flow in the river was 940 cubic feet per second. The data consist of measured stream mileages and time, distance, and concentration graphs of the dye cloud. The peak concentration traveled through the reach in 24 hours, averaging 1.5 miles per hour; the leading edge took about 22 hours, averaging 1.7 miles per hour; and the trailing edge took 35 hours, averaging 1.0 mile per hour. Data from this study were compared with methods for estimating time of travel for a range of stream discharges.
Opportunities for promoting youth physical activity: an examination of youth summer camps.
Hickerson, Benjamin D; Henderson, Karla A
2014-01-01
Youth summer camp programs have the potential to provide opportunities for physical activity, but little to no research has been conducted to determine activity levels of campers. This study aimed to examine physical activity occurring in day and resident summer camps and how activity levels differed in these camps based upon demographic characteristics. Pedometer data were collected during hours of camp operation from 150 day campers and 114 resident campers between the ages of 8 and 12 years old. Independent t tests were used to compare physical activity by sex, race, and Body Mass Index. Campers at day camps averaged 11,916 steps per camp day, while resident campers averaged 19,699 steps per camp day. Day campers averaged 1586 steps per hour over 7.5 hour days and resident campers averaged 1515 steps per hour over 13 hour days. Male sex, Caucasian race, and normal Body Mass Index were significant correlates of more physical activity. Youth summer camps demonstrate the potential to provide ample opportunities for physical activity during the summer months. Traditional demographic disparities persisted in camps, but the structure of camp programs should allow for changes to increase physical activity for all participants.
NASA Astrophysics Data System (ADS)
Labraga, Juan C.
1994-01-01
Wind farm settlement in Argentina is likely to be initiated in the extended and uniform Pampa del Castillo tablelands (5100 km2) in central cast Patagonia, due to its suitable wind regime and local economic factors. The magnitude of these investments requires not only a detailed wind energy assessment and optimum site selection but also a comprehensive evaluation of the extreme winds experienced in the region.Statistical results, with emphasis on severe winds, of two regional programs of one-year observations at four levels above the ground are presented in this paper. The highest frequencies of hourly mean wind velocities above 40, 60, and 80 km h1 are observed during November and December. The spring power spectrum shows a considerable amount of energy in components with a periodicity ranging from 2.5 to 4 days. Severe wind episodes are usually related to the displacement of low pressure systems from the Atlantic to the Pacific Ocean through the Drake Passage with a periodicity consistent with spectral results. The highest hourly mean wind speed registered in each experimental period (at 60 m AGL) is about 25 m s1. The estimated modal value of the theoretical probability distribution of annual extreme values is in good agreement with observed values. The annual peak gust for an averaging time of 240 s is about 27 m s. The gust factor was computed for different averaging intervals and compared with empirical formulations. Its variation with height and time of year was also analyzed. The general form of the vertical wind profile and its dependence on stability conditions was characterized and compared with that of typical episodes of severe winds.
Sleep duration from infancy to adolescence: reference values and generational trends.
Iglowstein, Ivo; Jenni, Oskar G; Molinari, Luciano; Largo, Remo H
2003-02-01
The main purpose of the present study was to calculate percentile curves for total sleep duration per 24 hours, for nighttime and for daytime sleep duration from early infancy to late adolescence to illustrate the developmental course and age-specific variability of these variables among subjects. A total of 493 subjects from the Zurich Longitudinal Studies were followed using structured sleep-related questionnaires at 1, 3, 6, 9, 12, 18, and 24 months after birth and then at annual intervals until 16 years of age. Gaussian percentiles for ages 3 months to 16 years were calculated for total sleep duration (time in bed) and nighttime and daytime sleep duration. The mean sleep duration for ages 1 to 16 years was estimated by generalized additive models based on the loess smoother; a cohort effect also had to be included. The standard deviation (SD) was estimated from the loess smoothed absolute residuals from the mean curve. For ages 3, 6, and 9 months, an alternative approach with a simple model linear in age was used. For age 1 month, empirical percentiles were calculated. Total sleep duration decreased from an average of 14.2 hours (SD: 1.9 hours) at 6 months of age to an average of 8.1 hours (SD: 0.8 hours) at 16 years of age. The variance showed the same declining trend: the interquartile range at 6 months after birth was 2.5 hours, whereas at 16 years of age, it was only 1.0 hours. Total sleep duration decreased across the studied cohorts (1974-1993) because of increasingly later bedtime but unchanged wake time across decades. Consolidation of nocturnal sleep occurred during the first 12 months after birth with a decreasing trend of daytime sleep. This resulted in a small increase of nighttime sleep duration by 1 year of age (mean 11.0 +/- 1.1 hours at 1 month to 11.7 +/- 1.0 hours at 1 year of age). The most prominent decline in napping habits occurred between 1.5 years of age (96.4% of all children) and 4 years of age (35.4%). Percentile curves provide valuable information on developmental course and age-specific variability of sleep duration for the health care professional who deals with sleep problems in pediatric practice.
Smith, Wally R; Coyne, Patrick; Smith, Virginia S; Mercier, Bruce
2003-09-01
Weather changes are among the proposed precursors of painful sickle cell crises. However, epidemiologic data are mixed regarding the relationship between ambient temperature and crisis frequency. To study this relationship among a local sickle cell disease population, emergency department (ED) visits and admissions were evaluated in adults with sickle cell crisis as the primary diagnosis at a major teaching hospital in a temperate climate. Official daily ambient temperatures (average for that day) were obtained from the National Climate Data Center for the days patients visited the ED or were hospitalized, and for 24 or 48 hours prior. Daily ED visit counts and admission counts were correlated with the visit/admission day's ambient temperature, with the ambient temperature 24 hours before admission, and with the magnitude of change in daily ambient temperature over the prior 24 or 48 hours. For all correlations, statistical significance was defined as a p value of <0.01 and clinical significance was defined as a moderate or greater correlation, absolute value of r >/= 0.30. ED visits or admissions correlated statistically, but not clinically, with daily temperatures. On days when temperatures were <32 degrees F or >80 degrees F, these correlations were statistically significant, but clinical significance was variable. ED visits or admissions correlated only statistically with temperatures 24 hours prior, even on days when temperatures were <32 degrees F. When temperatures were >80 degrees F, the correlations were statistically significant, but there was a reverse, clinically significant correlation between admissions and temperatures. Finally, only statistically significant correlations were found between ED visits or admissions and change in temperature over the prior 24 or 48 hours. Weak or inconsistent confirmation of a relationship was found between daily ambient temperatures and ED visits or hospital admissions for sickle cell crises.
Chih, Annie; Rudloff, Elke; Waldner, Cheryl; Linklater, Andrew K J
2018-05-01
To evaluate the incidence of hypochloremic metabolic alkalosis (HCMA) in dogs and cats in the ICU that had intermittent nasogastric tube (NGT) aspiration for up to 36 hours. Prospective cohort study (December 2013 to October 2014). Privately owned emergency and referral teaching hospital. Forty-nine client-owned dogs and 16 client-owned cats. Patients wherein NGT placement was recommended and client consent was obtained were included in the interventional group. Those with an NGT placed (NGT group) had the NGT aspirated every 4 hours. Patients for whom placement of a NGT was declined by the owner served as a reference group (NoNGT). Venous blood gas and electrolyte values were obtained every 12 hours. Thirty-five dogs and cats had an NGT placed. Thirty dogs and cats did not have an NGT placed. The serum venous blood gas and electrolyte changes were compared over time within the NGT group and between the NGT and NoNGT groups. No cases developed HCMA. In the NGT group, blood pH increased over time. There was no significant difference between the NGT and the NoNGT group in the average value of pH, HCO 3 - , base excess, chloride, or corrected chloride. Serum venous blood gas, chloride, and corrected chloride changes were not associated with the volumes of gastric fluid aspirated over time. In this small population of dogs and cats, intermittent NGT aspiration was not associated with the development of HCMA over a period of up to 36 hours after NGT placement. © Veterinary Emergency and Critical Care Society 2018.
The impact of household cooking and heating with solid fuels on ambient PM2.5 in peri-urban Beijing
NASA Astrophysics Data System (ADS)
Liao, Jiawen; Zimmermann Jin, Anna; Chafe, Zoë A.; Pillarisetti, Ajay; Yu, Tao; Shan, Ming; Yang, Xudong; Li, Haixi; Liu, Guangqing; Smith, Kirk R.
2017-09-01
Household cooking and space heating with biomass and coal have adverse impacts on both indoor and outdoor air quality and are associated with a significant health burden. Though household heating with biomass and coal is common in northern China, the contribution of space heating to ambient air pollution is not well studied. We investigated the impact of space heating on ambient air pollution in a village 40 km southwest of central Beijing during the winter heating season, from January to March 2013. Ambient PM2.5 concentrations and meteorological conditions were measured continuously at rooftop sites in the village during two winter months in 2013. The use of coal- and biomass-burning cookstoves and space heating devices was measured over time with Stove Use Monitors (SUMs) in 33 households and was coupled with fuel consumption data from household surveys to estimate hourly household PM2.5 emissions from cooking and space heating over the same period. We developed a multivariate linear regression model to assess the relationship between household PM2.5 emissions and the hourly average ambient PM2.5 concentration, and a time series autoregressive integrated moving average (ARIMA) regression model to account for autocorrelation. During the heating season, the average hourly ambient PM2.5 concentration was 139 ± 107 μg/m3 (mean ± SD) with strong autocorrelation in hourly concentration. The average primary PM2.5 emission per hour from village household space heating was 0.736 ± 0.138 kg/hour. The linear multivariate regression model indicated that during the heating season - after adjusting for meteorological effects - 39% (95% CI: 26%, 54%) of hourly averaged ambient PM2.5 was associated with household space heating emissions from the previous hour. Our study suggests that a comprehensive pollution control strategy for northern China, including Beijing, should address uncontrolled emissions from household solid fuel combustion in surrounding areas, particularly during the winter heating season.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monroe, J; Case Western Reserve University; Boparai, K
Purpose: A survey was taken by NRG Oncology to assess Full Time Equivalent (FTE) contributions to multi institutional clinical trials by medical physicists.No current quantification of physicists’ efforts in FTE units associated with clinical trials is available. The complexity of multi-institutional trials increases with new technologies and techniques. Proper staffing may directly impact the quality of trial data and outcomes. The demands on physics time supporting clinical trials needs to be assessed. Methods: The NRG Oncology Medical Physicist Subcommittee created a sixteen question survey to obtain this FTE data. IROC Houston distributed the survey to their list of 1802 contactmore » physicists. Results: After three weeks, 363 responded (20.1% response). 187 (51.5%) institutions reporting external beam participation were processed. There was a wide range in number of protocols active and supported at each institution. Of the 187 clinics, 134 (71.7%) participate in 0 to 10 trials, 28 (15%) in 11 to 20 trials, 10 (5.3%) in 21 to 30 trials, 9 (4.8%) had 40 to 75 trials. On average, physicist spent 2.7 hours (SD: 6.0) per week supervising or interacting with clinical trial staff. 1.25 hours (SD: 3.37), 1.83 hours (SD: 4.13), and 0.64 hours(SD: 1.13) per week were spent on patient simulation, reviewing treatment plans, and maintaining a DICOM server, respectively. For all protocol credentialing activities, physicist spent an average of 37.05 hours (SD: 96.94) yearly. To support dosimetrists, clinicians, and therapists, physicist spend on average 2.07 hours (SD: 3.52) per week just reading protocols. Physicist attended clinical trial meetings for on average 1.13 hours (SD: 1.85) per month. Conclusion: Responding physicists spend a nontrivial amount of time: 8.8 hours per week (0.22 FTE) supporting, on average, 9 active multi-institutional clinical trials.« less
Pirat, Bahar; Atar, Ilyas; Ertan, Cagatay; Bozbas, Huseyin; Gulmez, Oyku; Müderrisoglu, Haldun; Ozin, Bulent
2007-11-15
C-reactive protein (CRP) was increased in patients with atrial fibrillation (AF). The aim of this study was to evaluate CRP after inducing AF in 39 patients undergoing electrophysiologic study (EPS). After a diagnostic EPS, programmed atrial stimulation with 3 extra stimuli from the right atrium was performed in all patients. CRP was measured before and 6 and 24 hours after the procedure. Patients in whom AF was induced were monitored for 24 hours. AF was induced in 18 of 39 patients. Twenty-one patients without a tachyarrhythmia constituted the control group. Groups were similar with regard to age, gender, incidences of hypertension and diabetes, and history of coronary artery disease. On average, AF lasted 4.8 hours, and spontaneous conversion to sinus rhythm was observed in all patients. There were no statistically significant differences with respect to baseline and 6-hour CRP values between groups. However, mean CRP at 24 hours was significantly higher in patients with AF compared with controls (10 +/- 11 and 3.9 +/- 4.2 mg/L; p = 0.04). In conclusion, induction of AF during EPS led to increased CRP. This finding suggested that increased CRP may be the consequence of AF.
Mossetti, Stefano; de Bartolo, Daniela; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina; Nava, Elisa
2017-04-01
International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Saylor, Rick D.; Edgerton, Eric S.; Hartsell, Benjamin E.; Baumann, Karsten; Hansen, D. Alan
2010-12-01
Continuous ammonia (NH 3) measurements with a temporal resolution of 5 min were implemented at selected SEARCH sites in the southeastern U. S. during 2007. The SEARCH continuous NH 3 instrument uses a citric acid denuder difference technique employing a dual-channel nitric oxide-ozone chemiluminescence analyzer. Data from two SEARCH sites are presented, Jefferson Street, Atlanta (JST) (urban), and Yorkville, Georgia (YRK) (rural), for the period July-December, 2007. Highest NH x (total ammonia = gaseous NH 3 + PM 2.5 NH 4+) values were observed in August and September at both JST and YRK. Highest NH 3 values occurred in August and September at JST, but in August through October at YRK. Lowest NH 3 and NH x values occurred in December at both sites. YRK is significantly impacted by nearby poultry sources, routinely experiencing hourly average NH 3 mixing ratios above 20 ppbv. Wind sector analysis clearly implicates the nearby poultry operations as the source of the high NH 3 values. Weekday versus weekend differences in composite hourly mean diurnal profiles of NH 3 at JST indicate that mobile sources have a measurable but relatively small impact on NH 3 observed at that site, and little or no impact on NH 3 observed at YRK. A distinctive composite mean hourly diurnal variation was observed at both JST and YRK, exhibiting maxima in the morning and evening with a broad minimum during midday. Analysis of observed NH 3 diurnal variations from the literature suggests a hypothesized mechanism for the observed behavior based on interaction of local emissions and dry deposition with the formation and collapse of the dynamically mixed atmospheric boundary layer during the day and shallow nocturnal layer at night. Simple mixed layer concentration box model simulations confirm the plausibility of the suggested mechanism.
76 FR 64781 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-19
...-Hours FedEx stated that they averaged 800 work-hours versus the 632 work- hours listed in the NPRM (76... work- hours, as specified for the additional actions, may be adequate if done in conjunction with the other modifications; however, additional work- hours will be required for airplanes that have been...
Working hours and roster structures of surgical trainees in Australia and New Zealand.
O'Grady, Gregory; Loveday, Benjamin; Harper, Simon; Adams, Brandon; Civil, Ian D; Peters, Matthew
2010-12-01
The working hours of surgical trainees are a subject of international debate. Excessive working hours are fatiguing, and compromise performance, learning and work-life balance. However, reducing hours can impact on continuity of care, training experience and service provision. This study defines the current working hours of Australasian trainees, to inform the working hours debate in our regions. An online survey was conducted of all current Australasian trainees. Questions determined hours spent at work (AW) and off-site on-call (OC) per week, and roster structures were evaluated by training year, specialty and location. The response rate was 55.3%. Trainees averaged 61.4 ± 11.7 h/week AW, with 5% working ≥80 h. OC shifts were worked by 73.5%, for an average of 27.8 ± 14.3 h/week. Trainees of all levels worked similar hours (P= 0.10); however, neurosurgical trainees worked longer hours than most other specialties (P < 0.01). Tertiary centre rotations involved longer AW hours (P= 0.01) and rural rotations more OC (P < 0.001). Long days (>12 h) were worked by 86%; median frequency 1:4.4 days; median duration 15 h. OC shifts of 24-h duration were worked by 75%; median frequency 1:4.2 days; median sleep: 5-7 h/shift; median uninterrupted sleep: 3-5 h/shift. This study has quantified the working hours and roster structures of Australasian surgical trainees. By international standards, Australasian trainee working hours are around average. However, some rosters demand long hours and/or induce chronic sleep loss, placing some trainees at risk of fatigue. Ongoing efforts are needed to promote safe rostering practices. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.
The working hours of general practitioners 2000-2008.
Aasland, Olaf G; Rosta, Judith
2011-06-03
There is little reliable information available on the working hours of general practitioners (GPs). The purpose of our study is to describe the development of weekly working hours of Norwegian general practitioners in the period from 2000 to 2008, as well as the length of their patient lists and their perceived workload. General practitioners in the reference panel of the Research Institute of the Norwegian Medical Association have reported their weekly working hours for 2000, 2002, 2004, 2006 and 2008, and the length of their patient lists for 2002 and 2008. We used non-overlapping 95 per cent confidence intervals for testing inter-group differences in interval variables and proportions. From 227 to 316 general practitioners responded to each survey round. Average weekly working hours constituted 45.1 hours (95 per cent CI: 43.6-46.5 hours) in 2000 and 46.4 hours (95 per cent CI: 45.2-47.6 hours) in 2008. The number of hours increased for women GPs, while the number of hours remained basically unchanged for men from 2000 to 2008. Average length of the patient lists in 2002 and 2008 constituted 1,325 and 1,278 for men, and 1,155 and 1,144 for women GPs respectively. The proportion of GPs who responded that they perceived their workload as unacceptable decreased significantly, from 38.1 per cent in 2000 to 25.5 per cent in 2008. Average weekly working hours for GPs increased by approximately one hour from 2000 to 2008, and this increase is found mainly among women GPs. We believe that the reduction in the proportion reporting to have an unacceptable workload can be explained by the introduction of the list-patient system, which has given the doctors better control of their own workload.
Air quality at night markets in Taiwan.
Zhao, Ping; Lin, Chi-Chi
2010-03-01
In Taiwan, there are more than 300 night markets and they have attracted more and more visitors in recent years. Air quality in night markets has become a public concern. To characterize the current air quality in night markets, four major night markets in Kaohsiung were selected for this study. The results of this study showed that the mean carbon dioxide (CO2) concentrations at fixed and moving sites in night markets ranged from 326 to 427 parts per million (ppm) during non-open hours and from 433 to 916 ppm during open hours. The average carbon monoxide (CO) concentrations at fixed and moving sites in night markets ranged from 0.2 to 2.8 ppm during non-open hours and from 2.1 to 14.1 ppm during open hours. The average 1-hr levels of particulate matter with aerodynamic diameters less than 10 microm (PM10) and less than 2.5 microm (PM2.5) at fixed and moving sites in night markets were high, ranging from 186 to 451 microg/m3 and from 175 to 418 microg/m3, respectively. The levels of PM2.5 accounted for 80-97% of their respective PM10 concentrations. The average formaldehyde (HCHO) concentrations at fixed and moving sites in night markets ranged from 0 to 0.05 ppm during non-open hours and from 0.02 to 0.27 ppm during open hours. The average concentration of individual polycyclic aromatic hydrocarbons (PAHs) was found in the range of 0.09 x 10(4) to 1.8 x 10(4) ng/m3. The total identified PAHs (TIPs) ranged from 7.8 x 10(1) to 20 x 10(1) ng/m3 during non-open hours and from 1.5 x 10(4) to 4.0 x 10(4) ng/m3 during open hours. Of the total analyzed PAHs, the low-molecular-weight PAHs (two to three rings) were the dominant species, corresponding to an average of 97% during non-open hours and 88% during open hours, whereas high-molecular-weight PAHs (four to six rings) represented 3 and 12% of the total detected PAHs in the gas phase during non-open and open hours, respectively.
Fog at the Guarulhos International Airport from 1951 to 2015
NASA Astrophysics Data System (ADS)
França, Gutemberg Borges; do Carmo, Luiz Felipe Rodrigues; de Almeida, Manoel Valdonel; Albuquerque Neto, Francisco Leite
2018-02-01
This paper presents and discusses the fog occurrences before and after the construction of the Guarulhos International Airport, using data from 1951 to 2015. The analysis showed the following: (1) a total of 19,816 h of fog were registered. (2) The minimum average, mean and maximum average of the fog temperature had significantly increased after the airport was constructed from 1.2 to 6.9, 12.1 to 14.5 and 20.2 to 20.7 °C, respectively, due to the urban development around the airport during the study period. (3) The average fog hours per year decreased by approximately 73.1%, i.e., from 492 ± 84.45 to 132 ± 54.51 h per year. (4) Most of the fog events occurred due to longwave cooling on clear nights with relatively low wind speeds (characterizing radiation fog), with over 65% having duration of 2 h and occurring in the early hours of the day during March-September period. (5) The maximum probability of fog occurrence dropped about 10% from before to after the construction of the airport. Finally, two fog events are investigated using data collected during the fog evolution using atmospheric sounding profiles (from an acoustic sounder) and automatic meteorological stations and preliminary results showed that the values of cooling rate and turbulent kinetic energy play key roles in the onset and growth-dissipation phases of the fog, respectively.
Abbott, Joel E; Miller, Daniel L; Shi, William; Wenzler, David; Elkhoury, Fuad F; Patel, Nishant D; Sur, Roger L
2017-09-01
Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick. Given the known diurnal variation in pH, a single dipstick pH is unlikely to reflect the average daily urinary pH. Our goal was to determine whether multiple dipstick pH readings would be reliably comparable to pH from a 24-hour urine analysis. Kidney stone patients undergoing a 24-hour urine collection were enrolled and took images of dipsticks from their first 3 voids concurrently with the 24-hour collection. Images were sent to and read by a study investigator. The individual and mean pH from the dipsticks were compared to the 24-hour urine pH and considered to be accurate if the dipstick readings were within 0.5 of the 24-hour urine pH. The Bland-Altman test of agreement was used to further compare dipstick pH relative to 24-hour urine pH. Fifty-nine percent of patients had mean urinary pH values within 0.5 pH units of their 24-hour urine pH. Bland-Altman analysis showed a mean difference between dipstick pH and 24-hour urine pH of -0.22, with an upper limit of agreement of 1.02 (95% confidence interval [CI], 0.45-1.59) and a lower limit of agreement of -1.47 (95% CI, -2.04 to -0.90). We concluded that urinary dipstick based pH measurement lacks the precision required to guide medical management of nephrolithiasis and physicians should use 24-hour urine analysis to base their metabolic therapy.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... Securities Dealer. Agency form number: FR MSD-4; FR MSD-5. OMB control number: 7100-0100; 7100-0101... are municipal securities dealers. Estimated annual reporting hours: FR MSD-4, 20 hours; FR MSD-5, 13 hours. Estimated average hours per response: FR MSD-4, 1 hour; FR MSD-5, 0.25 hours. Number of...
10 CFR 170.20 - Average cost per professional staff-hour.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 2 2012-01-01 2012-01-01 false Average cost per professional staff-hour. 170.20 Section 170.20 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FEES FOR FACILITIES, MATERIALS, IMPORT AND EXPORT LICENSES, AND OTHER REGULATORY SERVICES UNDER THE ATOMIC ENERGY ACT OF 1954, AS AMENDED General...
SPATIAL VARIABILITY OF PM2.5 IN URBAN AREAS IN THE UNITED STATES
Epidemiologic time-series studies typically use either daily 24-hour PM concentrations averaged across several monitors in a city or data obtained at a ?central monitoring site' to relate to human health effects. If 24-hour average concentrations differ substantially across an ur...
45 CFR 98.71 - Content of reports.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Matching and Maintenance-of-Effort (MOE) Funds: (1) The total monthly family income for determining... of children; (5) Whether the head of the family is a single parent; (6) The sources of family income...) Average number of hours of care provided per week; (6) Average hourly amount paid for care; (7) Children...
40 CFR 57.302 - Performance level of interim constant controls.
Code of Federal Regulations, 2011 CFR
2011-07-01
... exceed the following: (i) For sulfuric acid plants on copper smelters, 12-hour running average; (ii) For sulfuric acid plants on lead smelters, 6-hour running average; (iii) For sulfuric acid plants on zinc... limitation shall take into account unavoidable catalyst deterioration in sulfuric acid plants, but may...
Toward Developing a Relative Value Scale for Medical and Surgical Services
Hsiao, William C.; Stason, William B.
1979-01-01
A methodology has been developed to determine the relative values of surgical procedures and medical office visits on the basis of resource costs. The time taken to perform the service and the complexity of that service are the most critical variables. Interspecialty differences in the opportunity costs of training and overhead expenses are also considered. Results indicate some important differences between the relative values based on resource costs and existing standards, prevailing Medicare charges, and California Relative Value Study values. Most dramatic are discrepancies between existing reimbursement levels and resource cost values for office visits compared to surgical procedures. These vary from procedure to procedure and specialty to specialty but indicate that, on the average, office visits are undervalued (or surgical procedures overvalued) by four- to five-fold. After standardizing the variations in the complexity of different procedures, the hourly reimbursement rate in 1978 ranged from $40 for a general practitioner to $200 for surgical specialists. PMID:10309112
Effect of age on pulmonary epithelial permeability in unanesthetized lambs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchison, A.A.; McNicol, K.J.; Loughlin, G.M.
1985-01-01
Pulmonary epithelial permeability was measured 1) in unanesthetized sheep, and 2) longitudinally in growing lambs. Awake sheep were intubated and a solution of /sup 51/Cr-ethylenediaminetetraacetic acid and /sup 125/I-antipyrine was instilled in the intrathoracic trachea via the nasotracheal tube. Arterial blood was drawn 1-25 minutes after the instillation. The ratios of the counts of /sup 51/Cr to /sup 125/I at 7, 10, and 13 min were calculated and averaged for each animal. Data from six adult sheep showed that the mean +/- SE of the permeability ratio was 0.012 +/- 0.003 and was reproducible over three months. When measured twicemore » within two hours, the second ratio was significantly higher than the first. One hour of general anesthesia with methoxyflurane did not alter the permeability ratio significantly. Ten lambs were studied longitudinally 10 hours and 5, 10, 20, and 30 days after delivery. Within the first 24 hours of life the permeability ratio was, significantly greater than the adult value. At five days there was no significant difference between lambs and adult sheep. Throughout the first month of life, the permeability ratio in lambs remained at at the adult level.« less
Interplanetary medium data book, appendix
NASA Technical Reports Server (NTRS)
King, J. H.
1977-01-01
Computer generated listings of hourly average interplanetary plasma and magnetic field parameters are given. Parameters include proton temperature, proton density, bulk speed, an identifier of the source of the plasma data for the hour, average magnetic field magnitude and cartesian components of the magnetic field. Also included are longitude and latitude angles of the vector made up of the average field components, a vector standard deviation, and an identifier of the source of magnetic field data.
Concentrations of methoxyflurane and nitrous oxide in veterinary operating rooms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, G.S.; Byland, R.R.
1982-02-01
The surgical rooms of 14 private veterinary practices were monitored to determined methoxyflurane (MOF) concentrations during surgical procedure under routine working conditions. The average room volume for these 14 rooms was 29 m3. The average MOF value for all rooms was 2.3 ppm, with a range of 0.7 to 7.4 ppm. Four of the 14 rooms exceeded the maximum recommended concentration of 2 ppm. Six rooms which had 6 or more air changes/hr averaged 1.1 ppm, whereas 8 rooms with less than 6 measurable air changes/hr averaged 3.2 ppm. Operating rooms that had oxygen flows of more than 1,000 cm3/minmore » averaged 4.4 ppm, whereas those with flows of less than 1,000 cm3/min averaged 1.5 ppm. The average time spent during a surgical procedure using MOF, for all 14 facilities, was 2 hours. Nitrous oxide (N/sub 2/O) concentrations were determined in 4 veterinary surgical rooms. The average N/sub 2/O concentration for 3 rooms without waste anesthetic gas scavenging was 138 ppm. Concentration of N/sub 2/O in the waste anesthetic gas-scavenged surgical room was 14 ppm, which was below the maximum recommended concentration of 25 ppm.« less
A Web-based tool for UV irradiance data: predictions for European and Southeast Asian sites.
Kift, Richard; Webb, Ann R; Page, John; Rimmer, John; Janjai, Serm
2006-01-01
There are a range of UV models available, but one needs significant pre-existing knowledge and experience in order to be able to use them. In this article a comparatively simple Web-based model developed for the SoDa (Integration and Exploitation of Networked Solar Radiation Databases for Environment Monitoring) project is presented. This is a clear-sky model with modifications for cloud effects. To determine if the model produces realistic UV data the output is compared with 1 year sets of hourly measurements at sites in the United Kingdom and Thailand. The accuracy of the output depends on the input, but reasonable results were obtained with the use of the default database inputs and improved when pyranometer instead of modeled data provided the global radiation input needed to estimate the UV. The average modeled values of UV for the UK site were found to be within 10% of measurements. For the tropical sites in Thailand the average modeled values were within 1120% of measurements for the four sites with the use of the default SoDa database values. These results improved when pyranometer data and TOMS ozone data from 2002 replaced the standard SoDa database values, reducing the error range for all four sites to less than 15%.
77 FR 42696 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-20
... construction awards, 30 requests for amendments to non-construction awards, 2 project service maps). Average Hours Per Response: 2 hours for an amendment to a construction award, 1 hour for an amendment to a non-construction award, 6 hours for a project service map. Burden Hours: 1,242. Needs and Uses: A recipient must...
Prerequisites for successful human sperm cryobanking: sperm quality and prefreezing holding time.
Yavetz, H; Yogev, L; Homonnai, Z; Paz, G
1991-04-01
Frozen-thawed donor semen was used in artificial inseminations and in vitro fertilization programs. Semen accepted for donation was characterized (mean +/- SE) by sperm concentration of 150 +/- 18.6 x 10(6)/mL, normal morphology of 57% +/- 1.4%, good progressive motility at 1 hour of 57% +/- 1.0%, and post-thaw motility of 45% +/- 1.0%. Delay of the freezing process for greater than 1 hour after semen delivery caused a deleterious effect to the freezability of sperm. The average monthly fecundability for the 1st 6 months after inseminations was 13.6%. This value decreased dramatically to 2.6% from the 7th month onward. In 74 IVF/embryo transfer (ET) cycles, the fertilization rate was 55.3% +/- 3.8%, pregnancy rate (PR) per ET was 39.6%, and the PR per woman was 42.8%.
NASA Astrophysics Data System (ADS)
Borhan, M. Z.; Ahmad, R.; Rusop, M.; Abdullah, S.
2012-11-01
Centella Asiatica (C. Asiatica)contains asiaticoside as bioactive constituent which can be potentially used in skin healing process. Unfortunately, the normal powders are difficult to be absorbed by the body effectively. In order to improve the value of use, nano C. Asiatica powder was prepared. The influence of milling time was carried out at 0.5, 2, 4, 6, 8 hours and 10 hours. The effect of ball milling at different times was characterized using particles size analysis and FTIR Spectroscopy. The fineness of ground product was evaluated by recording the z-Average (nm), undersize distribution and polydispersity index (PdI). The results show that the smallest size particles by mean is 233 nm while FTIR spectra shows that there is no changing in the major component in the C. Asiatica powders with milling time.
Noise Pollution: Do We Need a Solution? An Analysis of Noise in a Cardiac Care Unit.
Ryan, Kevin M; Gagnon, Matthew; Hanna, Tyler; Mello, Brad; Fofana, Mustapha; Ciottone, Gregory; Molloy, Michael
2016-08-01
Introduction Hospitals are meant to be places for respite and healing; however, technological advances and reliance on monitoring alarms has led to the environment becoming increasingly noisy. The coronary care unit (CCU), like the emergency department, provides care to ill patients while being vulnerable to noise pollution. The World Health Organization (WHO; Geneva, Switzerland) recommends that for optimum rest and healing, sound levels should average approximately 30 decibels (dB) with maximum readings less than 40 dB. Problem The purpose of this study was to measure and analyze sound levels in three different locations in the CCU, and to review alarm reports in relation to sound levels. Over a one-month period, sound recorders (Extech SDL600; Extech Instruments; Nashua, New Hampshire USA) were placed in three separate locations in the CCU at the West Roxbury Veterans' Administration (VA) Hospital (Roxbury, Massachusetts USA). Sound samples were recorded once per second, stored in Comma Separated Values format for Excel (Microsoft Corporation; Redmond, Washington USA), and then exported to Microsoft Excel. Averages were determined, plotted per hour, and alarm histories were reviewed to determine alarm noise effect on total noise for each location, as well as common alarm occurrences. Patient Room 1 consistently had the lowest average recordings, though all averages were >40 dB, despite decreases between 10:00 pm and 7:00 am. During daytime hours, recordings maintained levels >50 dB. Overnight noise remained above recommended levels 55.25% of the period in Patient Room 1 and 99.61% of the same time period in Patient Room 7. The nurses' station remained the loudest location of all three. Alarms per hour ranged from 20-26 during the day. Alarms per day averaged: Patient Room 1-57.17, Patient Room 7-122.03, and the nurses' station - 562.26. Oxygen saturation alarms accounted for 33.59% of activity, and heart-related (including ST segment and pacemaker) accounted for 49.24% of alarms. The CCU cares for ill patients requiring constant monitoring. Despite advances in technology, measured noise levels for the hospital studied exceeded WHO standards of 40 dB and peaks of 45 dB, even during night hours when patients require rest. Further work is required to reduce noise levels and examine effects on patient satisfaction, clinical outcomes, and length of stay. Ryan KM , Gagnon M , Hanna T , Mello B , Fofana M , Ciottone G , Molloy M . Noise pollution: do we need a solution? An analysis of noise in a cardiac care unit. Prehosp Disaster Med. 2016;31(4):432-435.
Rehabilitation of scoliosis patients with pain after surgery.
Weiss, Hans-Rudolf
2002-01-01
In our centre, the postoperative scoliosis rehabilitation consists in stabilizing postural and respiratory exercises lasting several hours a day (5 1/2 to 7 hours). Additionally to pain treatment, we apply pain physiotherapy, physical therapy, acupuncture and besides manual medicine, also a psychological intervention and pain treatment by medication. 46 patients suffered from heavier pain 10 or more years after scoliosis surgery. The patients reported their pain at the beginning and at the end of 3-6 week in-patient rehabilitation programme. We applied a visual analogous scale (VAS), a numerical scale (NS), a standardized adjective scale (VRS), and a pain frequency scale. All the patients with an average age of 36 years old (SD=16) and an average curve angle of 35 degrees thoracic (SD=36) and 26 degrees lumbar (SD=22) showed a decrease of the values on the pain intensity scale. Pain reduction was highly significant, as well as pain frequency. Chronic pain as a late result following scoliosis surgery can be reduced by an intensive in-patient rehabilitation, at least in the short term. There are further necessary studies in order to follow-up the long-term effect of postoperative rehabilitation.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-16
... Municipal Securities Dealer. Agency form number: FR MSD-4 and FR MSD-5. OMB control number: 7100-0100 and... activities as municipal securities dealers. Estimated annual reporting hours: FR MSD-4, 48 hours; and FR MSD-5, 36 hours. Estimated average hours per response: FR MSD-4, 1 hour; and FR MSD- 5, 0.25 hours...
Wang, Ling; Abdel-Aty, Mohamed; Wang, Xuesong; Yu, Rongjie
2018-02-01
There have been plenty of traffic safety studies based on average daily traffic (ADT), average hourly traffic (AHT), or microscopic traffic at 5 min intervals. Nevertheless, not enough research has compared the performance of these three types of safety studies, and seldom of previous studies have intended to find whether the results of one type of study is transferable to the other two studies. First, this study built three models: a Bayesian Poisson-lognormal model to estimate the daily crash frequency using ADT, a Bayesian Poisson-lognormal model to estimate the hourly crash frequency using AHT, and a Bayesian logistic regression model for the real-time safety analysis using microscopic traffic. The model results showed that the crash contributing factors found by different models were comparable but not the same. Four variables, i.e., the logarithm of volume, the standard deviation of speed, the logarithm of segment length, and the existence of diverge segment, were positively significant in the three models. Additionally, weaving segments experienced higher daily and hourly crash frequencies than merge and basic segments. Then, each of the ADT-based, AHT-based, and real-time models was used to estimate safety conditions at different levels: daily and hourly, meanwhile, the real-time model was also used in 5 min intervals. The results uncovered that the ADT- and AHT-based safety models performed similar in predicting daily and hourly crash frequencies, and the real-time safety model was able to provide hourly crash frequency. Copyright © 2017 Elsevier Ltd. All rights reserved.
75 FR 6174 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-08
... collection. Burden Hours: 13,985. Number of Respondents: 16,964. Average Hours per Response: 50 minutes... government employment, pay, and hours. Since there are many different types and sizes of governments, each...
Carvalho Júnior, Lúcio Honório de; Temponi, Eduardo Frois; Paganini, Vinícius Oliveira; Costa, Lincoln Paiva; Soares, Luiz Fernando Machado; Gonçalves, Matheus Braga Jacques
2015-01-01
the aim of this study is to evaluate the change in length of hospital stay postoperatively for Total Knee Arthroplasty after using femoral and sciatic nerve block. the medical records of 287 patients were evaluated, taking into account the number of hours of admission, the percentage and the reason for re-hospitalization within 30 days, as well as associated complications. All patients were divided into two groups according or not to whether they were admitted to ICU or not. During the years 2009 and 2010, isolated spinal anesthesia was the method used in the procedure. From 2011 on, femoral and sciatic nerve blocking was introduced. between the years 2009 and 2012, the average length of stay ranged from 74 hours in 2009 to 75.2 hours in 2010. The average length of stay in 2011 was 56.52 hours and 53.72 hours in 2012, all in the group of patients who did not remain in the ICU postoperatively. In the same period, among those in the group that needed ICU admission, the average length of stay was 138.7 hours in 2009, 90.25 hours in 2010, 79.8 hours in 2011, and 52.91 hours in 2012. During 2009 and 2010, the rate of re-hospitalization was 0%, while in 2011 and 2012, were 3.44% and 1%, respectively. according to this study, the use of femoral and sciatic nerve blocking after total knee arthroplasty allowed significant reduction in hospital stay.
CELL POPULATION KINETICS OF EXCISED ROOTS OF PISUM SATIVUM
Van't Hof, Jack
1965-01-01
The cell population kinetics of excised, cultured pea roots was studied with the use of tritiated thymidine and colchicine to determine (1) the influence of excision, (2) the influence of sucrose concentration, (3) the average mitotic cycle duration, and (4) the duration of mitosis and the G 1, S, and G 2 periods of interphase.1 The results indicate that the process of excision causes a drop in the frequency of mitotic figures when performed either at the beginning of the culture period or after 100 hours in culture. This initial decrease in frequency of cell division is independent of sucrose concentration, but the subsequent rise in frequency of division, after 12 hours in culture, is dependent upon sucrose concentration. Two per cent sucrose maintains the shortest mitotic cycle duration. The use of colchicine indicated an average cycle duration of 20 hours, whereas the use of tritiated thymidine produced an average cycle duration of 17 hours. PMID:5857253
Ntineri, A; Kollias, A; Zeniodi, M; Moyssakis, I; Georgakopoulos, D; Servos, G; Vazeou, A; Stergiou, G S
2015-06-01
Some studies suggested that ambulatory blood pressure (ABP) variability may provide useful information beyond that of average ABP levels. This study investigated the relationship between central ABP variability and target-organ damage in young individuals in whom the central-peripheral blood pressure discrepancy might be considerable. Apparently healthy adolescents and young adults referred for elevated blood pressure and healthy volunteers (age 12-26 years) were subjected to: (i) 24-hour monitoring of central ABP using a noninvasive brachial cuff-based oscillometric device (Mobil-O-Graph 24 h PWA); (ii) 24-hour pulse wave velocity (PWV) monitoring (Mobil-O-Graph 24 h PWA); (iii) echocardiographic determination of left ventricular mass index (LVMI); (iv) measurement (ultrasonography) of the common carotid intima-media thickness (IMT). The standard deviation (SD) of ABP (24-hour weighted/awake/asleep), as well as the respective coefficients of variation (CV) were used for assessing variability. The study included 68 individuals (mean age 18.7 ± 4.7 years, 52 males, body mass index [BMI] 24.5 ± 4.7 kg/m, 24 volunteers, 15 with hypertension [24-hour peripheral ABP >=95th percentile for adolescents or >=130/80 mmHg for adults]). LVMI was correlated with 24-hour/awake/asleep central systolic ABP (r=0.50/0.49/0.40, all p < 0.01), as well as with 24-hour weighted/awake/asleep SD of central systolic ABP (r = 0.40/0.37/0.30, all p < 0.05), whereas no association was observed for the respective CV. IMT was correlated with 24-hour/awake/asleep central pulse pressure (PP) (r = 0.37/0.33/0.27, all p < 0.05), 24-hour weighted/awake/asleep SD of central PP (r = 0.43/0.40/0.36, all p < 0.01) and the respective CV (r = 0.28/0.26/0.25, all p < 0.05). Regarding 24-hour PWV, there was a significant association with 24-hour/awake/asleep central systolic ABP (r = 0.94/0.88/0.84, all p < 0.001) and 24-hour weighted/awake/asleep SD of central PP (r = 0.48/0.51/0.25, all p < 0.05), but not with the respective CV. In multivariate regression analyses (independent variables: age, gender, BMI, central ABP and SD/CV of ABP values), LVMI and 24-hour PWV were determined by BMI, age, and 24-hour central systolic ABP, and IMT by male gender and 24-hour weighted SD of central PP. In young individuals, 24-hour central ABP variability appears to be associated only with early carotid damage when accounting for ABP levels, whereas LVMI and PWV are mainly determined by average ABP levels.
78 FR 54645 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Exporters Only'' form is used by exporters to report and pay premiums on insured shipments to various.... Frequency of Reporting of Use: Monthly. Government Expenses: Reviewing time per year: 7,800 hours. Average Wages per Hour: $42.50. Average Cost per Year: $331,500 (time*wages). Benefits and Overhead: 20%. Total...
29 CFR 778.400 - The provisions of section 7(g)(3) of the Act.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COMPENSATION Exceptions From the Regular Rate Principles Computing Overtime Pay on An âestablishedâ Rate § 778... Labor as being substantially equivalent to the average hourly earnings of the employee, exclusive of... average hourly earnings for the workweek exclusive of payments described in paragraphs (1) through (7) of...
40 CFR 63.2263 - Initial compliance demonstration for a dry rotary dryer.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operate a dry rotary dryer, you must demonstrate that your dryer processes furnish with an inlet moisture.... You must record the inlet furnish moisture content (dry basis) and inlet dryer operating temperature... highest recorded 24-hour average inlet furnish moisture content and the highest recorded 24-hour average...
40 CFR 63.2263 - Initial compliance demonstration for a dry rotary dryer.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operate a dry rotary dryer, you must demonstrate that your dryer processes furnish with an inlet moisture.... You must record the inlet furnish moisture content (dry basis) and inlet dryer operating temperature... highest recorded 24-hour average inlet furnish moisture content and the highest recorded 24-hour average...
78 FR 57852 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-20
... of Use: As needed. Government Reviewing Time per Year: Reviewing time per year: 285 hours. Average Wages per Hour: $42.50. Average Cost per Year: $12,113. (time*wages). Benefits and Overhead: 20%. Total... 1995. This collection of information is necessary, pursuant to 12 U.S.C. 635 (a)(1), to determine...
40 CFR 62.15330 - What must I include in the initial report?
Code of Federal Regulations, 2014 CFR
2014-07-01
... emissions. (3) The 4-hour block or 24-hour daily arithmetic average concentration of carbon monoxide... specifications in appendix B of 40 CFR part 60 in conducting the evaluation. (e) The maximum demonstrated load of... combustion unit uses activated carbon to control dioxins/furans or mercury emissions, the average carbon feed...
Predictive value of the cow's milk skin prick test in infantile colic.
Moravej, Hossein; Imanieh, Mohammad H; Kashef, Sara; Handjani, Farhad; Eghterdari, Fardin
2010-01-01
Infantile colic is a common problem among young infants. Cow's milk allergy has been suggested as one of the causes. We aimed to investigate the value of the cow's milk skin test for the diagnosis of cow's milk allergy in exclusively breast-fed infants with infantile colic. Exclusively breast-fed infants with infantile colic were enrolled in this study. On the first visit, the average hours of crying of the infant in a 24-h period were recorded and the cow's milk skin test was performed. If the infant had a positive skin test, elimination of cow's milk from the mothers' diet was advised. Infants with negative skin tests were divided into case and control groups. Cow's milk was eliminated from the diet of mothers in the case group. After 2 weeks, the number of hours of crying were recorded again. The reduction in the crying hours was compared between the two groups using the chi-square test. Skin tests were positive in 3 of 114 cases (2.6%) of infantile colic. All three cases recovered completely following elimination of cow's milk from the mother's diet. Among the 111 patients with negative skin tests, 77 patients completed the study: 35 in the case group and 42 in the control group. The reduction in crying hours in infants in the case group was not significantly different from that in the control group. Elimination of cow's milk from the mothers' diet is not beneficial for infants with a negative skin test. Infants with a positive skin test may benefit from this management.
NASA Astrophysics Data System (ADS)
Boulet, G.; Bahir, M.; Delogu, E.; Mougenot, B.; Bousbih, S.; Raimbault, B.; Fanise, P.; Saadi, S.; Chebbi, W.; Lili-Chabaane, Z.; Rivalland, V.; Lagouarde, J. P.; Olioso, A.
2016-12-01
The ability to monitor latent heat flux (LE) is relevant for applications requiring spatially-resolved estimates of moisture availability over large areas. Recently, a number of studies have focused on estimating surface energy fluxes via assimilation of land surface temperature (LST) observations into variational data assimilation (VDA) schemes. In this study, the performance of the combined-source variational data assimilation (CS-VDA) framework is assessed in detail using surface multitemporal heat fluxes collected at a Eucalypt forest savanna of Northern Australia. The CS VDA model treats the soil and vegetation as one medium. We extended previous studies, to a semi-arid ecosystem and included 1 and 3 hour global meteorological forcing data (GMD) rather than site-specific observations to drive CS VDA model. To implement the VDA model we relied on hourly water fluxes and meteorological measurements from an eddy covariance (EC) site located at our Australian study site. Using 1 and 3-hour average in-situ measurements, the mean difference between estimated and observed LE was ˜30%, which agreed with errors reported in the literature. We found that at least an 3 hour average meteorological data was required as input to the CS-VDA model, so 1-3-hourly temporal resolution MERRA-GMA and GLDAS, respectively, were used. We found that replacing local meteorological data with GMD reduced the performance of the LE estimation in comparison to in-situ measurements (GLDAS: RMSEdaily=98.52 W/m2, GMA: RMSEdaily=82.02 W/m2). Despite this, the model LE RMSE values at 8-day temporal scale (GMA: RMSE8-days=32.20 W/m2) was similar of those reported at this area by others models. This study provides the basis to produce an operational daily LE product using GMD dataset and LST remote sensing data within the CS-VDA algorithm.
Rey, M; Enjalbert, F; Monteils, V
2012-03-01
The objectives of this study were to characterize the establishment of ruminal fermentation and enzymatic activities in dairy calves from birth to weaning (d 83). Six Holstein calves, immediately separated from their mother at birth, were fed colostrum for 3 d after birth, and thereafter milk replacer, starter pelleted concentrate, and hay until d 83 of age. Ruminal samples were collected from each calf every day for the first 10 d, and additionally at d 12, 15, 19, 22, 26, 29, 33, 36, 40, 43, 47, 50, 55, 62, 69, and 83. Ruminal samples were collected 1h after milk feeding with a stomach tube. The pH and redox potential (E(h)) were immediately measured. Samples were kept for further determination of ammonia nitrogen (NH(3)-N) and volatile fatty acid (VFA) concentrations, and xylanase, amylase, urease, and protease activities. Ruminal pH averaged 6.69, 5.82, and 6.34, from d 1 to 9, d 10 to 40, and d 43 to 83 of age, respectively. At first day of life, the ruminal E(h) value was positive (+224 mV). From d 2 to 9, d 10 to 40, and d 43 to 83 of age, ruminal E(h) averaged -164, -115, and -141 mV, respectively. From d 1 to 3, d 4 to 22, and d 26 to 83 of age, NH(3)-N concentration averaged 60.1, 179.8, and 58.2 mg/L, respectively. No VFA were detected in ruminal samples collected on d 1 of life of calves. From d 2 to 10 and d 12 to 83 of age, ruminal total VFA concentration averaged 19.5 and 84.4mM, respectively. Neither ruminal xylanase or amylase activities were observed at d 1 of age. From d 5 to 15 and d 19 to 83 of age, the xylanase activity averaged 182.2 and 62.4 μmol of sugar released per hour per gram of ruminal content dry matter (DM), respectively. From d 5 to 83 of age, the amylase activity reached 35.4 μmol of sugar released per hour per gram of ruminal content DM. The ruminal ureolytic activity was observed with an average value of 6.9 μg of NH(3)-N released per minute per gram of ruminal content DM over the 83-d experimental period. From d 1 to 4 and d 5 to 83 of age, the proteolytic activity was 8.2 and 27.9 optical density units per hour per gram of ruminal content DM, respectively. The fermentative and enzymatic activities were rapidly established in the rumen from d 2 after birth. Most parameters did not evolve further after 1 mo of age. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Economic value of U.S. fossil fuel electricity health impacts.
Machol, Ben; Rizk, Sarah
2013-02-01
Fossil fuel energy has several externalities not accounted for in the retail price, including associated adverse human health impacts, future costs from climate change, and other environmental damages. Here, we quantify the economic value of health impacts associated with PM(2.5) and PM(2.5) precursors (NO(x) and SO(2)) on a per kilowatt hour basis. We provide figures based on state electricity profiles, national averages and fossil fuel type. We find that the economic value of improved human health associated with avoiding emissions from fossil fuel electricity in the United States ranges from a low of $0.005-$0.013/kWh in California to a high of $0.41-$1.01/kWh in Maryland. When accounting for the adverse health impacts of imported electricity, the California figure increases to $0.03-$0.07/kWh. Nationally, the average economic value of health impacts associated with fossil fuel usage is $0.14-$0.35/kWh. For coal, oil, and natural gas, respectively, associated economic values of health impacts are $0.19-$0.45/kWh, $0.08-$0.19/kWh, and $0.01-$0.02/kWh. For coal and oil, these costs are larger than the typical retail price of electricity, demonstrating the magnitude of the externality. When the economic value of health impacts resulting from air emissions is considered, our analysis suggests that on average, U.S. consumers of electricity should be willing to pay $0.24-$0.45/kWh for alternatives such as energy efficiency investments or emission-free renewable sources that avoid fossil fuel combustion. The economic value of health impacts is approximately an order of magnitude larger than estimates of the social cost of carbon for fossil fuel electricity. In total, we estimate that the economic value of health impacts from fossil fuel electricity in the United States is $361.7-886.5 billion annually, representing 2.5-6.0% of the national GDP. Published by Elsevier Ltd.
Li, Jifeng; Song, Yuze
2017-01-01
Abstract Background: This meta-analysis aimed to evaluate the efficiency and safety of transcutaneous electrical nerve stimulation (TENS) for pain control after total knee arthroplasty. Methods: A systematic search was performed in Medline (1966 to June 2017), PubMed (1966 to June 2017), Embase (1980 to June 2017), ScienceDirect (1985 to June 2017), and the Cochrane Library. Only randomized controlled trial (RCT) was included. The fixed/random effect model was used according to the heterogeneity tested by I2 statistic. Meta-analysis was performed using Stata 11.0 software. Results: Five RCTs including 472 patients met the inclusion criteria. The present meta-analysis indicated that there were significant differences between groups in terms of visual analogue scale score at 12 hours (average: 3.58 vs 4.34, SMD = −0.260, 95% CI: −0.442 to −0.078, P = .005), 24 hours (average: 3.18 vs 3.52, SMD = −0.244, 95% CI: −0.426 to −0.063, P = .008), and 48 hours (average: 2.70 vs 2.96, SMD = −0.214, 95% CI: −0.395 to −0.033, P = .021) after total knee arthroplasty. Significant differences were found regarding opioid consumption at 12 hours (average: 14.44 vs 18.54, SMD = −0.503, 95% CI: −0.687 to −0.319, P = .000), 24 hours (average: 16.10 vs 18.40, SMD = −0.262, 95% CI: −0.443 to −0.080, P = .005), and 48 hours (average: 12.92 vs 15.12, SMD = −0.183, 95% CI: −0.364 to −0.002, P = .048). Conclusion: TENS could significantly reduce pain and opioid consumption after total knee arthroplasty. In addition, there were fewer adverse effects in the TENS groups. Higher quality RCTs are required for further research. PMID:28906393
Refai, Majed; Brunelli, Alessandro; Varela, Gonzalo; Novoa, Nuria; Pompili, Cecilia; Jimenez, Marcelo F; Aranda, José Luis; Sabbatini, Armando
2012-04-01
Digitalized chest drainage systems allow for quantification of air leak and measurement of intrapleural pressure. Little is known about the value of intrapleural pressure during the postoperative phase and its role in the recovering process after pulmonary resection. The objective of this investigation was to measure the values of pleural pressure immediately before the removal of chest tube after different types of pulmonary lobectomy. Prospective observational analysis on 203 consecutive patients submitted to pulmonary lobectomy during a 12-month period at two centres. Multiple measurements were recorded in the last hour before the removal of chest tube and averaged for the analysis. All patients were seated in bed in a 45° up-right position or in a chair, had a single chest tube and were not connected to suction during the evaluation period. Analysis of variance (ANOVA) was used to assess the differences in pleural pressure between different types of lobectomies. The average maximum, minimum and differential pressures were -6.1, -19.5 and 13.3 cmH(2)O, respectively. The average pressures were similar in all types of lobectomies (ANOVA, P = 0.2) and ranged from -11 to -13 cmH(2)O, with the exception of right upper bilobectomy (-20 cmH(2)O, all P-values vs. other types of lobectomies <0.05). Similar values were also recorded for maximum pressures (range -4.4 to -8.4 cmH(2)O) and minimum pressures (-31.6 cmH(2)O vs. ranged from -15.4 to -20.5 cmH(2)O, all P-values <0.01). The average pleural pressure was not associated with FEV1 (P = 0.9), DLCO (P = 0.2) or FEV1/FVC ratio (P = 0.6), when tested with linear regression. Similarly, the average pleural pressure was similar in patients with and without COPD (-12.1 vs. -13.0 cmH(2)O, P = 0.4). The ANOVA test was used to assess differences in pressures between different lobectomies. The so-called water seal status may actually correspond to intrapleural pressures ranging from -13 to -20 cmH(2)O. Modern electronic chest drainage devices allow a stable control of the intrapleural pressure. Thus, the values found in this study may be used as target pressures for different types of lobectomies, in order to favour lung recovery after surgery.
Evaluation and Treatment of Essential Hypertension During Short Duration Space Flight
NASA Technical Reports Server (NTRS)
Rossum, Alfred C.; Baisden, Dennis L.
2000-01-01
During the last four decades of manned space flight, two individuals have successfully flown in space with the preflight diagnosis of essential hypertension (HTN). Treatment of this disease process in the astronaut population warrants special consideration particularly when selecting medication for a mission. A retrospective review of data offers two different clinical scenarios involving the treatment, or lack thereof, for essential hypertension during space flight. Case I; A Caucasian quinquagenerian diagnosed with HTN one year prior to the mission obtained flight certification after a negative diagnostic workup. The patient was placed on a diuretic. Preflight isolated blood pressure (BP) measurements averaged 138/102. Inflight, the patient electively declined medication. A 36-hour BP monitor revealed an average value of 124/87. Postflight, BP measurements returned to preflight BP values. Case II: A Caucasian quatrogenerian diagnosed with HTN 6 months prior to launch completed flight training after a negative diagnostic workup. The patient was placed on an ACE inhibiter. Preflight BP measurements averaged 130/80. Inflight, isolated BP measurements were considerably less. Normotensive values were obtained postflight. In both cases, BP values inflight were lower than pre or postflight values. Yelle et al has confirmed similar findings in the normotensive astronaut population. Spaceflight may result in fluid shifting, mild dehydration, electrolyte imbalance, orthostatic hypotension, and increased heart rates. Based on these factors, certain classes of antihypertensive agents such as vasodilators, beta-blockers, and diuretics are excluded from consideration as a primary therapeutic modality. To date, Ace Inhibitors are viewed as the more acceptable drug of choice during spaceflight. Newer classes of drugs may also provide additional choices. Presently, astronauts developing uncomplicated HTN may continue their careers when treated with the appropriate class of continue their careers when treated with the appropriate class of antihypertensive medication.
Basner, Mathias; Dinges, David F; Shea, Judy A; Small, Dylan S; Zhu, Jingsan; Norton, Laurie; Ecker, Adrian J; Novak, Cristina; Bellini, Lisa M; Volpp, Kevin G
2017-04-01
Fatigue from sleep loss is a risk to physician and patient safety, but objective data on physician sleep and alertness on different duty hour schedules is scarce. This study objectively quantified differences in sleep duration and alertness between medical interns working extended overnight shifts and residents not or rarely working extended overnight shifts. Sleep-wake activity of 137 interns and 87 PGY-2/3 residents on 2-week Internal Medicine and Oncology rotations was assessed with wrist-actigraphy. Alertness was assessed daily with a brief Psychomotor Vigilance Test (PVT) and the Karolinska Sleepiness Scale. Interns averaged 6.93 hours (95% confidence interval [CI] 6.84-7.03 hours) sleep per 24 hours across shifts, significantly less than residents not working overnight shifts (7.18 hours, 95% CI 7.06-7.30 hours, p = .007). Interns obtained on average 2.19 hours (95% CI 2.02-2.36 hours) sleep during on-call nights (17.5% obtained no sleep). Alertness was significantly lower on mornings after on-call nights compared to regular shifts (p < .001). Naps between 9 am and 6 pm on the first day post-call were frequent (90.8%) and averaged 2.84 hours (95% CI 2.69-3.00 hours), but interns still slept 1.66 hours less per 24 hours (95% CI 1.56-1.76 hours) compared to regular shift days (p < .001). Sleep inertia significantly affected alertness in the 60 minutes after waking on-call. Extended overnight shifts increase the likelihood of chronic sleep restriction in interns. Reduced levels of alertness after on-call nights need to be mitigated. A systematic comparison of sleep, alertness, and safety outcomes under current and past duty hour rules is encouraged. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.
Dinges, David F.; Shea, Judy A.; Small, Dylan S.; Zhu, Jingsan; Norton, Laurie; Ecker, Adrian J.; Novak, Cristina; Bellini, Lisa M.; Volpp, Kevin G.
2017-01-01
Abstract Study Objectives: Fatigue from sleep loss is a risk to physician and patient safety, but objective data on physician sleep and alertness on different duty hour schedules is scarce. This study objectively quantified differences in sleep duration and alertness between medical interns working extended overnight shifts and residents not or rarely working extended overnight shifts. Methods: Sleep–wake activity of 137 interns and 87 PGY-2/3 residents on 2-week Internal Medicine and Oncology rotations was assessed with wrist-actigraphy. Alertness was assessed daily with a brief Psychomotor Vigilance Test (PVT) and the Karolinska Sleepiness Scale. Results: Interns averaged 6.93 hours (95% confidence interval [CI] 6.84–7.03 hours) sleep per 24 hours across shifts, significantly less than residents not working overnight shifts (7.18 hours, 95% CI 7.06–7.30 hours, p = .007). Interns obtained on average 2.19 hours (95% CI 2.02–2.36 hours) sleep during on-call nights (17.5% obtained no sleep). Alertness was significantly lower on mornings after on-call nights compared to regular shifts (p < .001). Naps between 9 am and 6 pm on the first day post‐call were frequent (90.8%) and averaged 2.84 hours (95% CI 2.69–3.00 hours), but interns still slept 1.66 hours less per 24 hours (95% CI 1.56–1.76 hours) compared to regular shift days (p < .001). Sleep inertia significantly affected alertness in the 60 minutes after waking on-call. Conclusions: Extended overnight shifts increase the likelihood of chronic sleep restriction in interns. Reduced levels of alertness after on-call nights need to be mitigated. A systematic comparison of sleep, alertness, and safety outcomes under current and past duty hour rules is encouraged. PMID:28329124
Road Traffic Noise Pollution Analysis for Cernavoda City
NASA Astrophysics Data System (ADS)
Manea, L.; Manea, A.; Florea, D.; Tarulescu, S.
2017-10-01
In the present paper was studied the noise pollution in Cernavodă city. The noise measurements were made for nine intersections from different city areas. Noise measurements were taken for three chosen routes with high population density, heavy traffic, commercial and residential buildings. Average, maximum and minimum values were collected and compared with standards. The impact of road traffic noise on the community depends on various factors such as road location and design, land use planning measures, building design, traffic composition, driver behaviour and the relief. In the study area 9 locations are identified to measure noise level. By using sound level meter noise levels are measured at different peak sessions i.e. morning, afternoon and evening. The presented values were collected for evening rush hour.
5 CFR 550.183 - Substantial hours requirement.
Code of Federal Regulations, 2010 CFR
2010-01-01
....184. This average is computed by dividing the total unscheduled duty hours for the annual period... workday means each day in the criminal investigator's basic workweek during which the investigator works at least 4 hours, excluding— (1) Overtime hours compensated under 5 U.S.C. 5542 and § 550.111; (2...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Thermal oxidizer a. The average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.3967(a) i. Collecting the combustion temperature... 3-hour average combustion temperature at or above the temperature limit. 2. Catalytic oxidizer a...
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Thermal oxidizer a. The average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.3967(a) i. Collecting the combustion temperature... 3-hour average combustion temperature at or above the temperature limit. 2. Catalytic oxidizer a...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Thermal oxidizer a. The average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.3967(a) i. Collecting the combustion temperature... 3-hour average combustion temperature at or above the temperature limit. 2. Catalytic oxidizer a...
Dental Assisting Education in California.
ERIC Educational Resources Information Center
California State Dept. of Education, Sacramento. Bureau of Industrial Education.
A survey of 22 dental assisting programs showed an average of 1,124 hours of instruction in dental assisting for 15 four-semester, 955 for three three-semester, and 1,042 for four two-semester programs. The average instructional hours for the four-semester programs were 48 in introduction to dental assisting, 179 in the life sciences, 221 in the…
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CPMS) to measure and record the hourly average total regeneration stream mass flow during each carbon... during regeneration (except during the cooling cycle). (3) Use a CPMS to measure and record the hourly average temperature of the adsorption bed after regeneration (and within 15 minutes after completing any...
40 CFR Table 1 to Subpart III of... - Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... determining compliance using this method Cadmium 0.004 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of part 60). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance...
40 CFR Table 1 to Subpart III of... - Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... determining compliance using this method Cadmium 0.004 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of part 60). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance...
40 CFR Table 8 to Subpart Ddddd of... - Demonstrating Continuous Compliance
Code of Federal Regulations, 2012 CFR
2012-07-01
...(c). 5. Dry Scrubber Sorbent or Carbon Injection Rate a. Collecting the sorbent or carbon injection... the data to 3-hour block averages; and c. Maintaining the 3-hour average sorbent or carbon injection... established during the performance test according to §§ 63.7530(c). 7. Fuel Pollutant Content a. Only burning...
40 CFR Table 8 to Subpart Ddddd of... - Demonstrating Continuous Compliance
Code of Federal Regulations, 2010 CFR
2010-07-01
...(c). 5. Dry Scrubber Sorbent or Carbon Injection Rate a. Collecting the sorbent or carbon injection... the data to 3-hour block averages; and c. Maintaining the 3-hour average sorbent or carbon injection... established during the performance test according to §§ 63.7530(c). 7. Fuel Pollutant Content a. Only burning...
40 CFR Table 8 to Subpart Ddddd of... - Demonstrating Continuous Compliance
Code of Federal Regulations, 2011 CFR
2011-07-01
...(c). 5. Dry Scrubber Sorbent or Carbon Injection Rate a. Collecting the sorbent or carbon injection... the data to 3-hour block averages; and c. Maintaining the 3-hour average sorbent or carbon injection... established during the performance test according to §§ 63.7530(c). 7. Fuel Pollutant Content a. Only burning...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
.... families. Estimated annual reporting hours: 8,938 hours. Estimated average hours per response: Pretest, 75 minutes; and Main survey, 75 minutes. Number of respondents: Pretest, 150; and Main survey, 7,000. General...
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1974-01-01
The capacity of the cells ranged from 6.6 to 7.6 ampere hours during the three capacity tests. No voltage requirements or limits were exceeded during any portion of the test. All cells recovered to a voltage in excess of 1.193 volts during the 24-hour open-circuit portion of the internal short test. All the cells reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test. The average ampere/hours in and voltages at this pressure were 9.1 and 1.513, respectively. All cells exhibited pressure decay in the range of 1 to 5 psia during the last 30 minutes of the 1-hour open circuit stand. Average capacity out was 7.2 ampere/hours.
Electrified atmospheric dust during disturbed weather conditions in the Negev desert
NASA Astrophysics Data System (ADS)
Katz, Shai; Yair, Yoav; Price, Colin; Yaniv, Roy
2017-04-01
Dust storms over the Negev Desert in southern Israel are common and become frequent during the spring and autumn, depending on synoptic conditions and local effects. These storms are often accompanied by significant dust electrification, most likely due to saltation and triboelectric processes. We present new atmospheric electrical measurements conducted at the Wise Observatory (WO) in Mizpe-Ramon (30035'N, 34045'E) Israel, during two strong dust storms that occurred over the Negev desert on October 27-28th and December 1st, 2016. The first event generated a local gust front due to strong downdrafts from an active Cumulonimbus cloud (known as Haboob). In the second event, a Cyprus Low with strong synoptic-scale winds lifted the local sand particles at the Negev and lowered the visibility. During the passage of the dust storms above our instruments, very large fluctuations in the electric field (Ez) and current density (Jz) were measured. In the October Haboob event, the Ez data showed a superposition of signatures generated by lightning and by the dust aloft. The Ez values fluctuated between +123 to +2144 and -15336 to +19788 V m-1 for several hour-long episodes. The respective values of the vertical current density [Jz] were between -18 and +18 pA m-2. During the December dust storm we measured Ez values up to +4000 V m-1 lasting for 3.5 hours and another episode with values up to +668 V m-1 lasting for approximately 1.5 hours. These values were accompanied by changes in the Jz values between -16.5 and +17 pA m-2. The electric field and current density variability and amplitude are significantly different from the average fair-weather values measured at the Wise Observatory (Yaniv et al., 2016), which are 180 V m-1 and 2 pA m-1. We will show that these differences in the electrical behavior between these two dust storms may be related to the speed and direction of the wind near the surface.
Liquid smoke characteristics from the pyrolysis of oil palm fronds
NASA Astrophysics Data System (ADS)
Maulina, S.; Silia, F.
2018-02-01
This study was conducted as means to characterize the pyrolysis of oil palm fronds into more economical products. In particular, this study was focused on pyrolysis of oil palm fronds, which could generate products such as liquid smoke, tar and char. Four characteristics of liquid smoke were examined in this study, namely the yield of liquid smoke, phenolic content, total acid content and pH. These characteristics were examined in a temperature of 150 °C, 200 °C and 250 °C with processing time of 60 minutes, 90 minutes and 120 minutes. This study revealed that the highest yield of liquid smoke was equal to 43.47% at a temperature of 150 °C for approximately 2 hours, while the highest level of phenolic was obtained at a temperature of 250 °C for approximately 1 hour. Moreover, the highest total acid content obtained was 11.23% at a temperature of 150 °C with a time of 1 hour. In addition, all operating conditions has produced liquid smoke with an average pH value of 3.
Maegawa, Hiroshi; Morino, Katsutaro; Nishio, Yoshihiko; Sato, Toshiyuki; Okada, Seiki; Kikkawa, Yasuo; Watanabe, Toshihiro; Nakajima, Hiromu; Kashiwagi, Atsunori
2016-01-01
Background Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. Methods Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. Results AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. Conclusion Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration. PMID:27535643
Ugi, Satoshi; Maegawa, Hiroshi; Morino, Katsutaro; Nishio, Yoshihiko; Sato, Toshiyuki; Okada, Seiki; Kikkawa, Yasuo; Watanabe, Toshihiro; Nakajima, Hiromu; Kashiwagi, Atsunori
2016-08-01
Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.
Dexter, Franklin; Epstein, Richard H; Dutton, Richard P; Kordylewski, Hubert; Ledolter, Johannes; Rosenberg, Henry; Hindman, Bradley J
2016-12-01
Anesthesiologists providing care during off hours (ie, weekends or holidays, or cases started during the evening or late afternoon) are more likely to care for patients at greater risk of sustaining major adverse events than when they work during regular hours (eg, Monday through Friday, from 7:00 AM to 2:59 PM). We consider the logical inconsistency of using subspecialty teams during regular hours but not during weekends or evenings. We analyzed data from the Anesthesia Quality Institute's National Anesthesia Clinical Outcomes Registry (NACOR). Among the hospitals in the United States, we estimated the average number of common types of anesthesia procedures (ie, diversity measured as inverse of Herfindahl index), and the average difference in the number of common procedures between 2 off-hours periods (regular hours versus weekends, and regular hours versus evenings). We also used NACOR data to estimate the average similarity in the distributions of procedures between regular hours and weekends and between regular hours and evenings in US facilities. Results are reported as mean ± standard error of the mean among 399 facilities nationwide with weekend cases. The distributions of common procedures were moderately similar (ie, not large, <.8) between regular hours and evenings (similarity index .59 ± .01) and between regular hours and weekends (similarity index, .55 ± .02). For most facilities, the number of common procedures differed by <5 procedures between regular hours and evenings (74.4% of facilities, P < .0001) and between regular hours and weekends (64.7% of facilities, P < .0001). The average number of common procedures was 13.59 ± .12 for regular hours, 13.12 ± .13 for evenings, and 9.43 ± .13 for weekends. The pairwise differences by facility were .13 ± .07 procedures (P = .090) between regular hours and evenings and 3.37 ± .12 procedures (P < .0001) between regular hours and weekends. In contrast, the differences were -5.18 ± .12 and 7.59 ± .13, respectively, when calculated using nationally pooled data. This was because the numbers of common procedures were 32.23 ± .05, 37.41 ± .11, and 24.64 ± .12 for regular hours, evenings, and weekends, respectively (ie, >2x the number of common procedures calculated by facility). The numbers of procedures commonly performed at most facilities are fewer in number than those that are commonly performed nationally. Thus, decisions on anesthesia specialization should be based on quantitative analysis of local data rather than national recommendations using pooled data. By facility, the number of different procedures that take place during regular hours and off hours (diversity) is essentially the same, but there is only moderate similarity in the procedures performed. Thus, at many facilities, anesthesiologists who work principally within a single specialty during regular work hours will likely not have substantial contemporary experience with many procedures performed during off hours.
Crack networks in damaged glass
NASA Astrophysics Data System (ADS)
Mallet, Celine; Fortin, Jerome; Gueguen, Yves
2013-04-01
We investigate how cracks develop and propagate in synthetic glass samples. Cracks are introduced in glass by a thermal shock of 300oC. Crack network is documented from optical and electronic microscopy on these samples that have been submitted to a thermal shock only. Samples are cylinder of 80 mm length and 40 mm diameter. Sections were cut along the cylinder axis and perpendicular to it. Using SEM, crack lengths and apertures can be measured. Optical microscopy allows to get the crack distribution over the entire sample. The sample average crack length is 3 mm. The average aperture is 6 ± 3μm. There is however a clear difference between the sample core, where the crack network has approximatively a transverse isotrope symmetry and the outer ring, where cracks are smaller and more numerous. By measuring before and after the thermal treatment the radial P and S wave velocities in room conditions, we can determine the total crack density which is 0.24. Thermally cracked samples, as described above, were submitted to creep tests. Constant axial stress and lateral stress were applied. Several experiments were performed at different stress values. Samples are saturated for 48 hours (to get an homogeneous pore fluid distribution), the axial stress is increased up to 80% of the sample strength. Stress step tests were performed in order to get creep data. The evolution of strain (axial and radial strain) is measured using strain gages, gap sensors (for the global axial strain) and pore volume change (for the volumetric strain). Creep data are interpreted as evidence of sub-critical crack growth in the cracked glass samples. The above microstructural observations are used, together with a crack propagation model, to account for the creep behavior. Assuming that (i) the observed volumetric strain rate is due to crack propagation and (ii) crack aspect ratio is constant we calculate the creep rate. We obtain some value on the crack propagation during a 24 hours of constant stress test. At each of these test, crack propagate of 0.3 to 0.4 mm. From the initial average crack length of 3 mm, the crack reach the size of 5.8 mm at the end of a complete creep test (with 8 constant stress step of 24 hours).
Witt, Julia
2017-01-01
Rural recruitment and retention continues to present challenges to health workforce planners. This paper reports and analyzes the results of a survey sent to physicians in Manitoba, eliciting their opinions regarding rural jobs. A survey was sent to all physicians in Manitoba. Part 1 of the survey included questions about background and demographic information; part 2 was a set of job satisfaction questions regarding respondents' current job; and part 3 included 2 sets of stated-choice questions eliciting preferences for a set of attributes relevant to rural recruitment and retention. Of the 2487 physicians who received surveys, 561 (22.6%) responded. Respondents indicated that income, hours worked and on-call frequency are very important: overall job satisfaction increased with income and decreased with hours worked. Income, hours and on-call frequency were ranked "very important" by the largest proportions of physicians. The estimated compensation for on-call more frequent than 1-in-4 was very high (82% of average income), and additional hours worked were worth $183 per hour. Other attributes that were important included professional interaction, housing availability and community incentives during the first year, which were valued at 11%-31% of annual income. Work-life balance is a key consideration for rural jobs, and there are incentives that can compensate for less desirable attributes.
77 FR 30994 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-24
...: National Oceanic and Atmospheric Administration (NOAA). Title: Scientific Research, Exempted Fishing, and.... Average Hours per Response: Scientific research plans, 37 hours; scientific research reports, 3 hours... information collection. Fishery regulations do not generally affect scientific research activities conducted...
A study of the surface energy balance on slopes in a tallgrass prairie
NASA Technical Reports Server (NTRS)
Nie, D.; Demetriades-Shah, T.; Kanemasu, E. T.
1990-01-01
Four slopes (north, south, east, and west) were selected on the Konza Prairie Research Natural Area to study the effect of topography on surface energy balance and other micrometeorological variables. Energy fluxes, air temperature, and vapor pressure were measured on the sloped throughout the 1988 growing season. Net radiation was the highest on the south-facing slope and lowest on the north-facing slope, and the difference was more than 150 W/sq m (20 to 30 percent) at solar noon. For daily averages, the difference was 25 W/sq m (15 percent) early in the season and increased to 60 W/sq m (30 to 50 percent) in September. The east-facing and west-facing slopes had the same daily average net radiation, but the time of day when maximum net radiation occurred was one hour earlier for the east-facing slope and one hour later for the west-facing slope relative to solar noon. Soil heat fluxes were similar for all the slopes. The absolute values of sensible heat flux (h) was consistently lower on the north-facing slope compared with other slopes. Typical difference in the values of H between the north-facing and the south-facing slopes was 15 to 30 W/sq m. The south-facing slope had the greatest day to day fluctuation in latent heat flux as a result of interaction of net radiation, soil moisture, and green leaf area. The north-facing slope had higher air temperatures during the day and higher vapor pressures both during the day and at night when the wind was from the south.
Spatial distribution of precipitation extremes in Norway
NASA Astrophysics Data System (ADS)
Verpe Dyrrdal, Anita; Skaugen, Thomas; Lenkoski, Alex; Thorarinsdottir, Thordis; Stordal, Frode; Førland, Eirik J.
2015-04-01
Estimates of extreme precipitation, in terms of return levels, are crucial in planning and design of important infrastructure. Through two separate studies, we have examined the levels and spatial distribution of daily extreme precipitation over catchments in Norway, and hourly extreme precipitation in a point. The analyses were carried out through the development of two new methods for estimating extreme precipitation in Norway. For daily precipitation we fit the Generalized Extreme Value (GEV) distribution to areal time series from a gridded dataset, consisting of daily precipitation during the period 1957-today with a resolution of 1x1 km². This grid-based method is more objective and less manual and time-consuming compared to the existing method at MET Norway. In addition, estimates in ungauged catchments are easier to obtain, and the GEV approach includes a measure of uncertainty, which is a requirement in climate studies today. Further, we go into depth on the debated GEV shape parameter, which plays an important role for longer return periods. We show that it varies according to dominating precipitation types, having positive values in the southeast and negative values in the southwest. We also find indications that the degree of orographic enhancement might affect the shape parameter. For hourly precipitation, we estimate return levels on a 1x1 km² grid, by linking GEV distributions with latent Gaussian fields in a Bayesian hierarchical model (BHM). Generalized linear models on the GEV parameters, estimated from observations, are able to incorporate location-specific geographic and meteorological information and thereby accommodate these effects on extreme precipitation. Gaussian fields capture additional unexplained spatial heterogeneity and overcome the sparse grid on which observations are collected, while a Bayesian model averaging component directly assesses model uncertainty. We find that mean summer precipitation, mean summer temperature, latitude, longitude, mean annual precipitation and elevation are good covariate candidates for hourly precipitation in our model. Summer indices succeed because hourly precipitation extremes often occur during the convective season. The spatial distribution of hourly and daily precipitation differs in Norway. Daily precipitation extremes are larger along the southwestern coast, where large-scale frontal systems dominate during fall season and the mountain ridge generates strong orographic enhancement. The largest hourly precipitation extremes are mostly produced by intense convective showers during summer, and are thus found along the entire southern coast, including the Oslo-region.
Stochastic mixing of protons from chaotic orbits in the nightside geomagnetosphere
NASA Technical Reports Server (NTRS)
Horton, W.; Liu, C.; Hernandez, J.; Tajima, T.
1991-01-01
The stochastic mixing of protons in the energy range from 1 to 30 keV in the nightside magnetosphere is studied by calculating the local divergence rate of neighboring orbits and the two-time velocity correlation function. The rate of divergence of neighboring bundles of trajectories is shown to have large bursts with average separation times of order 1 minute per e-folding during the crossing of the central plasma sheet in the region beyond -50 Re. For the Tsyganenko magnetosphere the net amount of orbit divergence is 15 to 20 e-foldings in one hour. The velocity correlations are shown to decay as power laws r-m with a distribution of m values. These results indicate that for short time (less than 1 hour) there is reversibility and memory for the protons but for longer times there is no memory for protons in the nightside magnetosphere.
Resident Duty Hours: Enhancing Sleep, Supervision, and Safety
ERIC Educational Resources Information Center
Ulmer, Cheryl, Ed.; Wolman, Dianne Miller, Ed.; Johns, Michael M. E., Ed.
2009-01-01
Medical residents in hospitals are often required to be on duty for long hours. In 2003 the organization overseeing graduate medical education adopted common program requirements to restrict resident workweeks, including limits to an average of 80 hours over 4 weeks and the longest consecutive period of work to 30 hours in order to protect…
44 CFR 353.5 - Average cost per FEMA professional staff-hour.
Code of Federal Regulations, 2014 CFR
2014-10-01
... professional staff-hour. 353.5 Section 353.5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT... cost per FEMA professional staff-hour. Fees for FEMA services rendered will be calculated based upon the costs for such services using a professional staff rate per hour equivalent to the sum of the...
44 CFR 353.5 - Average cost per FEMA professional staff-hour.
Code of Federal Regulations, 2010 CFR
2010-10-01
... professional staff-hour. 353.5 Section 353.5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT... cost per FEMA professional staff-hour. Fees for FEMA services rendered will be calculated based upon the costs for such services using a professional staff rate per hour equivalent to the sum of the...
44 CFR 353.5 - Average cost per FEMA professional staff-hour.
Code of Federal Regulations, 2011 CFR
2011-10-01
... professional staff-hour. 353.5 Section 353.5 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT... cost per FEMA professional staff-hour. Fees for FEMA services rendered will be calculated based upon the costs for such services using a professional staff rate per hour equivalent to the sum of the...
Grossi, E A; Steinberg, B M; LeBoutillier, M; Coppa, G F; Roses, D F
1994-08-01
The current quantity and diversity of hospital clinical, laboratory, and pharmacy records have resulted in a glut of information, which can be overwhelming to house staff. This study was performed to measure the impact of artificial intelligence analysis of such data on the junior surgical house staff's workload, time for direct patient care, and quality of life. A personal computer was interfaced with the hospital computerized patient data system. Artificial intelligence algorithms were applied to retrieve and condense laboratory values, microbiology reports, and medication orders. Unusual laboratory tests were reported without artificial intelligence filtering. A survey of 23 junior house staff showed a requirement for a total of 30.75 man-hours per day, an average of 184.5 minutes per service twice a day for five surgical services each with an average of 40.7 patients, to manually produce a report in contrast to a total of 3.4 man-hours, an average of 20.5 minutes on the same basis (88.9% reduction, p < 0.001), to computer generate and distribute a similarly useful report. Two thirds of the residents reported an increased ability to perform patient care. Current medical practice has created an explosion of information, which is a burden for surgical house staff. Artificial intelligence preprocessing of the hospital database information focuses attention, eliminates superfluous data, and significantly reduces surgical house staff clerical work, allowing more time for education, research, and patient care.
Long working hours in Korea: results of the 2010 Working Conditions Survey.
Park, Jungsun; Kwon, Oh Jun; Kim, Yangho
2012-01-01
Long working hours adversely affect workers' safety and health. In 2004, Korea passed legislation limiting the working week to 40 h, to improve quality-of-life and to increase business competitiveness. In the present study, we explored the characteristics of work in Korea and compared our data of the second Korean Working Conditions Survey (KWCS) with those of the first KWCS. We found that the average number of hours worked weekly has been reduced but the proportions of workers who work for more than 48 h per week has increased over the 4 yr between the two Korean surveys in all categories studied (male, female, employee, self-employed, and employer). We also found that self-employed and employers work much longer hours than do employees, who are protected by the Labor Standards Act. This was particularly true in the accommodation and food service sectors. In conclusion, Korean workers work longer than do workers of EU countries. The use of average figures masks differences in the numbers of working hours among those engaged in various types of employment, or in certain work sectors. Therefore, the Korean government should not simply monitor reductions in average weekly working hours, but should identify employees working for over 60 h weekly, and reduce their working time.
Hydrogeology of glacial deposits in a preglacial bedrock valley, Waukesha County, Wisconsin
Batten, W.G.; Conlon, T.D.
1993-01-01
Results of a 6.5-hour aquifer test indicate that the silty sand and gravel deposits have an average transmissivity of about 140 feet squared per day and an average storage coefficient of about 1.2x10"3 at one location. The horizontal hydraulic conductivity of these deposits averages about 4 feet per day. Analysis of drawdown indicates that these deposits are part of a leaky confined-aquifer system and that some water is derived from storage in an overlying clay layer. The transmissivity value determined from this aquifer test and a lack of clean sand and gravel encountered in other test holes indicate that glacial deposits at these sites may not yield enough water for a large municipal water supply. Sand and gravel deposits, capable of development as a municipal supply, may be present in the southern part of the study area. However, additional test holes are needed to determine whether adequate sand and gravel deposits underlie this area.
Permeation Resistance of Personal Protective Equipment Materials to Monomethyhydrazine
NASA Technical Reports Server (NTRS)
Waller, J. M.; Williams, J. H.
1997-01-01
Permeation resistance was determined by measuring the breakthrough time and time-averaged vapor transmission rate of monomethylhydrazine (MMH) through two types of personal protective equipment (PPE). The two types of PPE evaluated were the totally encapsulating ILC Dover Chemturion Model 1212 chemical protective suit with accessories, and the FabOhio polyvinyl chloride (PVC) splash garment. Two exposure scenarios were simulated: (1) a saturated vapor exposure for 2 hours (h), and (2) a brief MMH 'splash' followed by a 2-h saturated vapor exposure. Time-averaged MMH concentrations inside the totally-encapsulating suit were calculated by summation of the area-weighted contributions made by each suit component. Results show that the totally encapsulating suit provides adequate protection at the new 10 ppb Threshold Limit Value Time-Weighted Average (TLV-TWA). The permeation resistance of the PVC splash garment to MMH was poorer than any of the totally encapsulating suit materials tested. Breakthrough occurred soon after initial vapor or 'splash' exposure.
BOREAS AES Five-Day Averaged Surface Meteorological and Upper Air Data
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Strub, Richard; Newcomer, Jeffrey A.
2000-01-01
The Canadian Atmospheric Environment Service (AES) provided BOREAS with hourly and daily surface meteorological data from 23 of the AES meteorological stations located across Canada and upper air data from 1 station at The Pas, Manitoba. Due to copyright restrictions on the full resolution surface meteorological data, this data set contains 5-day average values for the surface parameters. The upper air data are provided in their full resolution form. The 5-day averaging was performed in order to create a data set that could be publicly distributed at no cost. Temporally, the surface meteorological data cover the period of January 1975 to December 1996 and the upper air data cover the period of January 1961 to November 1996. The data are provided in tabular ASCII files, and are classified as AFM-staff data. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
Code of Federal Regulations, 2011 CFR
2011-07-01
... basis and analyzes the samples with gas chromatography or, if the owner or operator assumes that all... concentration of vinyl chloride in the exhaust gases does not exceed 10 ppm (average for 3-hour period), or... chloride in the exhaust gases does not exceed 10 ppm (average for 3-hour period), or equivalent as provided...
50 CFR 218.80 - Specified activity and specified geographical region.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Study Area also includes U.S. Navy pierside locations where sonar maintenance and testing occurs within...): (A) M3—an average of 461 hours per year. (B) [Reserved] (vii) Swimmer Detection Sonar (SD): (A) SD1 and SD2—an average of 230 hours per year. (B) [Reserved] (viii) Forward Looking Sonar (FLS): (A) FLS2...
40 CFR Table 4 to Subpart Ppppp of... - Initial Compliance With Emission Limitations
Code of Federal Regulations, 2013 CFR
2013-07-01
... . . . 1. CO or THC concentration emission limitation The first 4-hour rolling average CO or THC concentration is 20 ppmvd or less, corrected to 15 percent O2 content. 2. CO or THC percent reduction emission limitation The first 4-hour rolling average reduction in CO or THC is 96 percent or more, dry basis...
40 CFR Table 4 to Subpart Ppppp of... - Initial Compliance With Emission Limitations
Code of Federal Regulations, 2012 CFR
2012-07-01
... . . . 1. CO or THC concentration emission limitation The first 4-hour rolling average CO or THC concentration is 20 ppmvd or less, corrected to 15 percent O2 content. 2. CO or THC percent reduction emission limitation The first 4-hour rolling average reduction in CO or THC is 96 percent or more, dry basis...
40 CFR Table 4 to Subpart Ppppp of... - Initial Compliance With Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... . . . 1. CO or THC concentration emission limitation The first 4-hour rolling average CO or THC concentration is 20 ppmvd or less, corrected to 15 percent O2 content. 2. CO or THC percent reduction emission limitation The first 4-hour rolling average reduction in CO or THC is 96 percent or more, dry basis...
40 CFR Table 4 to Subpart Ppppp of... - Initial Compliance With Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... . . . 1. CO or THC concentration emission limitation The first 4-hour rolling average CO or THC concentration is 20 ppmvd or less, corrected to 15 percent O2 content. 2. CO or THC percent reduction emission limitation The first 4-hour rolling average reduction in CO or THC is 96 percent or more, dry basis...
40 CFR Table 4 to Subpart Ppppp of... - Initial Compliance With Emission Limitations
Code of Federal Regulations, 2014 CFR
2014-07-01
... . . . 1. CO or THC concentration emission limitation The first 4-hour rolling average CO or THC concentration is 20 ppmvd or less, corrected to 15 percent O2 content. 2. CO or THC percent reduction emission limitation The first 4-hour rolling average reduction in CO or THC is 96 percent or more, dry basis...
40 CFR Table 1 to Subpart Cccc of... - Emission Limitations
Code of Federal Regulations, 2011 CFR
2011-07-01
... per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B of appendix A of this...
ERIC Educational Resources Information Center
Beswick, Adele
2007-01-01
Weather consists of those meteorological events, such as rain, wind and sunshine, which can change day-by-day or even hour-by-hour. Climate is the average of all these events, taken over a period of time. The climate varies over different parts of the world. Climate is usually defined as the average of the weather over a 30-year period. It is when…
40 CFR Table 1 to Subpart Cccc of... - Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B of appendix A of this...
40 CFR Table 2 to Subpart Dddd of... - Model Rule-Emission Limitations
Code of Federal Regulations, 2010 CFR
2010-07-01
... meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part) Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B, of appendix A of this part) Dioxins/furans...
2002-07-01
0704-0188 Public reporting burder for this collection of information is estibated to average 1 hour per response, including the time for reviewing...information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and...information operations and reports, 1215 Jefferson davis highway, suite 1204, Arlington, VA 22202-4302, and to the office of management and budget, paperwork
Adverse health effects and unhealthy behaviors among medical students using Facebook.
Al-Dubai, Sami Abdo Radman; Ganasegeran, Kurubaran; Al-Shagga, Mustafa Ahmed Mahdi; Yadav, Hematram; Arokiasamy, John T
2013-01-01
Little is known about the relationships between adverse health effects and unhealthy behaviors among medical students using Facebook. The aim of this study was to determine the associations between adverse health effects and unhealthy behaviors with Facebook use. A cross-sectional study was conducted in a private university in Malaysia among 316 medical students. A self-administered questionnaire was used. It included questions on sociodemographics, pattern of Facebook use, social relationship, unhealthy behaviors, and health effects. Mean age was 20.5 (±2.7) years. All students had a Facebook account. The average daily Facebook surfing hours were 2.5 (±1.7). Significant associations were found between average hours of Facebook surfing and the following factors: isolation from family members and community, refusing to answer calls, musculoskeletal pain, headache, and eye irritation (P < 0.005). The average hours spent on Facebook were significantly associated with holding urination and defecation while online, surfing Facebook until midnight, and postponing, forgetting, or skipping meals (P < 0.005). The average hours spent on Facebook were associated with adverse health effects and unhealthy behaviors among medical students, as well as social isolation from the family and community.
Adverse Health Effects and Unhealthy Behaviors among Medical Students Using Facebook
Al-Dubai, Sami Abdo Radman; Al-Shagga, Mustafa Ahmed Mahdi; Yadav, Hematram; Arokiasamy, John T.
2013-01-01
Little is known about the relationships between adverse health effects and unhealthy behaviors among medical students using Facebook. The aim of this study was to determine the associations between adverse health effects and unhealthy behaviors with Facebook use. A cross-sectional study was conducted in a private university in Malaysia among 316 medical students. A self-administered questionnaire was used. It included questions on sociodemographics, pattern of Facebook use, social relationship, unhealthy behaviors, and health effects. Mean age was 20.5 (±2.7) years. All students had a Facebook account. The average daily Facebook surfing hours were 2.5 (±1.7). Significant associations were found between average hours of Facebook surfing and the following factors: isolation from family members and community, refusing to answer calls, musculoskeletal pain, headache, and eye irritation (P < 0.005). The average hours spent on Facebook were significantly associated with holding urination and defecation while online, surfing Facebook until midnight, and postponing, forgetting, or skipping meals (P < 0.005). The average hours spent on Facebook were associated with adverse health effects and unhealthy behaviors among medical students, as well as social isolation from the family and community. PMID:24453859
NASA Astrophysics Data System (ADS)
Chernov, D. G.; Kozlov, V. S.; Panchenko, M. V.; Turchinovich, Yu. S.; Radionov, V. F.; Gubin, A. V.; Prakhov, A. N.
2015-11-01
In 2011-2014, the Institute of Atmospheric Optics (IAO SB RAS, Tomsk) and the Arctic and Antarctic Research Institute (AARI, St. Petersburg) conducted field investigations of the near-ground aerosol characteristics near Barentsburg (Spitsbergen Archipelago) in the spring and summer seasons. The particle number density in the size range 0.3-20 μm, size distribution of particles, and mass concentrations of aerosol and black carbon were measured round-the-clock every hour with Grimm 1.108 and 1.109; and AZ-10 optical counters. The mass concentration of black carbon was measured by the MDA-02 aethalometer developed by the IAO SB RAS. Series of observations are obtained, annual and seasonal average values and their standard deviations are estimated, and seasonal and annual dynamics of the studied parameters is analyzed. Peculiarities of the temporal dynamics of average values of the aerosol characteristics are revealed and compared with the data of observations at other stations of the Spitsbergen Archipelago and in different regions of the Russian Arctic and Subarctic.
Muraoka, Kenichi; Yoshida, Satoshi; Hasegawa, Kazumasa; Nakanishi, Nobuo; Fukuzawa, Isao; Tomita, Akio; Cyong, Jong Chol
2004-10-01
The phagocytic activity of macrophages as a novel approach to scientific elucidation of the effects of Chinese medicines was studied through administration of a kampo preparation, by measuring the rise in body temperature, which is thought to stimulate innate defensive functions of organisms and enhance the immune systems. Using dogs as experimental models, a rise in body temperature following administration of Kakkon-to was observed, and the average number and average rate of phagocytosis of macrophages in blood using latex micro-particles was investigated. The body temperature of the treated animals significantly increased 30 minutes after administration (p<0.01), and remained elevated for more than 5 hours. A comparison of body temperatures before and after administration showed significant increases over controls from 1 to 11 hours, p<0.01; and at 12 hours, p<0.05 after administration. The average number and the average rate of phagocytosis were significantly increased 1 (p<0.05) and 2 (p<0.01) hours after administration. The mean number of phagocytized cells significantly increased (p<0.05) at 1 hour after administration compared with that before administration, and the mean phagocytic rate also increased significantly (p<0.01) 2 hours after administration. Increases (p<0.01) in both the rate of phagocytosis and the number of cells phagocytized were found at every measurement point from 2 to 24 hours after administration. Significant increases (p<0.01) were also observed in both the rate of phagocytosis and the number of cells phagocytized 3 hours after administration, when compared with the control group. This paper demonstrates that ingestion of Kakkon-to not only increases the body temperature but also enhances the phagocytic activity of macrophages, an in vivo defense mechanism, suggesting that Kakkon-to contributes to the suppression of multiplication of common cold viruses and influenza viruses, which consequently results in improvement of various symptoms during infection with common cold viruses.
CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.
2014-05-27
Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15more » minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.« less
CALiPER Report 21.3. Cost Effectiveness of Linear (T8) LED Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-05-01
Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15more » minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
....011) 3-run average (1-hour minimum sample time per run) EPA Reference Method 5 of appendix A-3 of part... by volume (ppmv) 20 5.5 11 3-run average (1-hour minimum sample time per run) EPA Reference Method 10... dscf) 16 (7.0) or 0.013 (0.0057) 0.85 (0.37) or 0.020 (0.0087) 9.3 (4.1) or 0.054 (0.024) 3-run average...
Advertisement scheduling on commercial radio station using genetics algorithm
NASA Astrophysics Data System (ADS)
Purnamawati, S.; Nababan, E. B.; Tsani, B.; Taqyuddin, R.; Rahmat, R. F.
2018-03-01
On the commercial radio station, the advertising schedule is done manually, which resulted in ineffectiveness of ads schedule. Playback time consists of two types such as prime time and regular time. Radio Ads scheduling will be discussed in this research is based on ad playback schedule between 5am until 12am which rules every 15 minutes. It provides 3 slots ads with playback duration per ads maximum is 1 minute. If the radio broadcast time per day is 12 hours, then the maximum number of ads per day which can be aired is 76 ads. The other is the enactment of rules of prime time, namely the hours where the common people (listeners) have the greatest opportunity to listen to the radio, namely between the hours and hours of 4 am - 8 am, 6 pm - 10 pm. The number of screenings of the same ads on one day are limited to prime time ie 5 times, while for regular time is 8 times. Radio scheduling process is done using genetic algorithms which are composed of processes initialization chromosomes, selection, crossover and mutation. Study on chromosome 3 genes, each chromosome will be evaluated based on the value of fitness calculated based on the number of infractions that occurred on each individual chromosome. Where rule 1 is the number of screenings per ads must not be more than 5 times per day and rule 2 is there should never be two or more scheduling ads delivered on the same day and time. After fitness value of each chromosome is acquired, then the do the selection, crossover and mutation. From this research result, the optimal advertising schedule with schedule a whole day and ads data playback time ads with this level of accuracy: the average percentage was 83.79%.
Seismicity and eruptive activity at Fuego Volcano, Guatemala: February 1975 -January 1977
Yuan, A.T.E.; McNutt, S.R.; Harlow, D.H.
1984-01-01
We examine seismic and eruptive activity at Fuego Volcano (14??29???N, 90?? 53???W), a 3800-m-high stratovolcano located in the active volcanic arc of Guatemala. Eruptions at Fuego are typically short-lived vulcanian eruptions producing ash falls and ash flows of high-alumina basalt. From February 1975 to December 1976, five weak ash eruptions occurred, accompanied by small earthquake swarms. Between 0 and 140 (average ??? 10) A-type or high-frequency seismic events per day with M > 0.5 were recorded during this period. Estimated thermal energies for each eruption are greater by a factor of 106 than cumulative seismic energies, a larger ratio than that reported for other volcanoes. Over 4000 A-type events were recorded January 3-7, 1977 (cumulative seismic energy ??? 109 joules), yet no eruption occurred. Five 2-hour-long pulses of intense seismicity separated by 6-hour intervals of quiescence accounted for the majority of events. Maximum likelihood estimates of b-values range from 0.7 ?? 0.2 to 2.1 ?? 0.4 with systematically lower values corresponding to the five intense pulses. The low values suggest higher stress conditions. During the 1977 swarm, a tiltmeter located 6 km southeast of Fuego recorded a 14 ?? 3 microradian tilt event (down to SW). This value is too large to represent a simple change in the elastic strain field due to the earthquake swarm. We speculate that the earthquake swarm and tilt are indicative of subsurface magma movement. ?? 1984.
Projecting the Water and Electric Consumption of Polytechnic University of the Philippines
NASA Astrophysics Data System (ADS)
Urrutia, Jackie D.; Mercado, Joseph; Bautista, Lincoln A.; Baccay, Edcon B.
2017-03-01
This study investigates water and electric consumption in Polytechnic University of the Philippines - Sta. Mesa using a time series analysis. The researchers analyzed the water and electric usage separately. Electric consumption was examined in terms of pesos and kilowatt-hour, while water consumption was analyzed in pesos and cubic meter. The data are gathered from the university limited only from January 2009 to July 2015 in a monthly based record. The aim is to forecast the water and electric usage of the university for the years 2016 and 2017. There are two main statistical treatments that the researchers conducted to be able to formulate mathematical models that can estimate the water and electric consumption of the said school. Using Seasonal Autoregressive Integrated Moving Average (SARIMA), electric usage was forecasted in peso and kilowatt-hour, and water usage in peso and cubic meter. Moreover, the predicted values of the consumptions are compared to the actual values using Paired T-test to examine whether there is a significant difference. Forecasting accurately the water and electric consumption would be helpful to manage the budget allotted for the water and electric consumption of PUP - Sta. Mesa for the next two years.
29 CFR 778.321 - Decrease in hours without decreasing pay-general.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COMPENSATION Special Problems Reduction in Workweek Schedule with No Change in Pay § 778.321 Decrease in hours without decreasing pay—general. Since the regular rate of pay is the average hourly rate at which an... 29 Labor 3 2010-07-01 2010-07-01 false Decrease in hours without decreasing pay-general. 778.321...
29 CFR 778.324 - Effect on hourly rate employees.
Code of Federal Regulations, 2010 CFR
2010-07-01
... pay, the average hourly rate is thereby increased as in § 778.322. If the reduction in work schedule... Problems Reduction in Workweek Schedule with No Change in Pay § 778.324 Effect on hourly rate employees. A similar situation is presented where employees have been hired at an hourly rate of pay and have...
29 CFR 778.321 - Decrease in hours without decreasing pay-general.
Code of Federal Regulations, 2011 CFR
2011-07-01
... COMPENSATION Special Problems Reduction in Workweek Schedule with No Change in Pay § 778.321 Decrease in hours without decreasing pay—general. Since the regular rate of pay is the average hourly rate at which an... 29 Labor 3 2011-07-01 2011-07-01 false Decrease in hours without decreasing pay-general. 778.321...
29 CFR 778.324 - Effect on hourly rate employees.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pay, the average hourly rate is thereby increased as in § 778.322. If the reduction in work schedule... Problems Reduction in Workweek Schedule with No Change in Pay § 778.324 Effect on hourly rate employees. A similar situation is presented where employees have been hired at an hourly rate of pay and have...
77 FR 31684 - Hours of Service of Drivers: RockTenn, Exemption Application
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-29
... 14th hour of coming on duty. This exemption will allow these individuals to occasionally work up to 16 consecutive hours and be allowed to return to work with less than the mandatory 10 consecutive hours off duty... public road--Compress Street--an average of forty times per day to travel between its manufacturing...
Code of Federal Regulations, 2014 CFR
2014-07-01
... operating limit by— 1. Thermal oxidizer The average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.5725(d) a. Collecting the combustion temperature data according to § 63.5725(d); b. reducing the data to 3-hour block averages; and c...
Code of Federal Regulations, 2013 CFR
2013-07-01
... operating limit by— 1. Thermal oxidizer The average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.5725(d) a. Collecting the combustion temperature data according to § 63.5725(d); b. reducing the data to 3-hour block averages; and c...
Code of Federal Regulations, 2012 CFR
2012-07-01
... operating limit by— 1. Thermal oxidizer The average combustion temperature in any 3-hour period must not fall below the combustion temperature limit established according to § 63.5725(d) a. Collecting the combustion temperature data according to § 63.5725(d); b. reducing the data to 3-hour block averages; and c...
75 FR 71368 - Erik Erb; Notice of Receipt of Petition for Rulemaking
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-23
... requirement for security officers working 12-hour shifts from an average of 3 days per week to 2.5 or 2 days... the minimum days off (MDO) requirement for security officers working 12- hour shifts from an average of 3 days per week to 2.5 or 2 days per week. The NRC is also requesting public comments on the PRM...
50 CFR 216.240 - Specified activity and specified geographical region.
Code of Federal Regulations, 2011 CFR
2011-10-01
... mode)—up to 1080 hours over the course of 5 years (an average of 216 hours per year). (4) AN/BQQ-10 or... 2952 dips per year—10 pings per five-minute dip). (6) SSQ-62 (Directional Command Activated Sonobuoy... years (an average of 872 buoys per year). (10) AN/SQQ-32 (over the side mine-hunting sonar)—up to 22370...
Clearcut harvesting costs and production rates for young-growth mixed-conifer stands
William A. Atkinson; Dale O. Hall
1966-01-01
In clearcutting 90-year-old stands at the Challenge Experimental Forest, all merchantable trees greater than 12 inches d.b.h. were removed. Felling costs averaged $3.86 and required 0.55 man-hours per M bd. ft. in cut volumes averaging 19,700 bd. ft. per acre. Yarding, at a rate of 0.54 hours per M bd. ft., cost $4.42.
Ionospheric irregularities over Bahir Dar, Ethiopia during selected geomagnetic storms
NASA Astrophysics Data System (ADS)
Kassa, Tsegaye; Damtie, Baylie
2017-07-01
We have analyzed the effect of geomagnetic storms on the occurrence of ionospheric irregularities by considering seven case studies in the period of 2013-2014 over Bahir Dar, Ethiopia (11° N , 38° E). We inferred the irregularity indices from GPS phase fluctuation by computing the median of 1-min rate of change of total electron content (fp) along the ray paths from all satellites observed. The Fp -index was calculated as an hourly average fp -index values along the ray paths from all satellites observed during each hour. Our results revealed that the irregularity level was inhibited during post sunset hours of the main phase of the storms we considered. On average, the irregularity index has dropped from 400 (0.4 TECU/min) during quiet time to 50 (0.05 TECU/min) on disturbed time with an amount of 350 (0.35 TECU/min). However, in some of the cases, immediately after the onset of the storm, we observed the enhancement of irregularities. We found that only the observations on 01 June 2013 and 19 February 2014 exhibited a correspondence of the time of occurrence of the minimum of the Dst-index with inhibition of irregularities noted by other researchers. Our observations of the enhancement of irregularities on 17 March 2013 and 19 February 2014 can partly be explained by the orientation of the IMF BZ . Other measurements such as neutral wind, electric field are required to explain the observations on 29 June 2013, 06 July 2013, 09 November 2013 and 27 February 2014.
Particulate pollution in different housing types in a UK suburban location.
Nasir, Zaheer Ahmad; Colbeck, Ian
2013-02-15
To investigate the levels of particulate pollution in residential built environments measurements of PM(10), PM(2.5), and PM(1) and concentrations were made between 2004 and 2008 in various residencies in a UK suburban location. Measurements were carried out in three different residential settings (Types I, II and III). In type I non-smoking living rooms, the highest 24-hour mean concentrations were found in summer. When smoking took place in type I residences, the concentrations of PM(10), PM(2.5) and PM(1), during the winter were almost double those in summer. In type II houses the concentrations were higher in the houses with open plan kitchens than in those with separate kitchens. In type III houses, mean concentrations were significantly higher in wood heated living rooms than those using central heating. In kitchens, cooking resulted in substantially higher concentrations of particulate matter with levels above those in smoking living rooms in winter. The hourly maximum values of number concentration were considerably higher in smoking rooms than non-smoking ones. Cooking resulted in increased number concentrations, with the average hourly maximum concentration of 179,110 #/cm(3). Particle mass and number emission rates were determined for a number of activities. In kitchens grilling had the highest average number emission rate, followed by boiling and frying. The results clearly highlight the impact of different forms of dwelling and their use and management by occupants on the levels of particulate matter in naturally ventilated residential built environments. Copyright © 2012 Elsevier B.V. All rights reserved.
Choi, BongKyoo; Choi, SangJun; Jeong, JeeYeon; Lee, JiWon; Shu, Shi; Yu, Nu; Ko, SangBaek; Zhu, Yifang
2016-01-01
Few studies have examined ambulatory cardiovascular physiological parameters of taxi drivers while driving in relation to their occupational hazards. This study aims to investigate and quantify the impact of worksite physical hazards as a whole on ambulatory heart rate of professional taxi drivers while driving without their typical worksite psychosocial stressors. Ambulatory heart rate (HR driving ) of 13 non-smoking male taxi drivers (24 to 67 years old) while driving was continuously assessed on their 6-hour experimental on-road driving in Los Angeles. Percent maximum HR range (PMHR driving ) of the drivers while driving was estimated based on the individual HR driving values and US adult population resting HR (HR rest ) reference data. For analyses, the HR driving and PMHR driving data were split and averaged into 5-min segments. Five physical hazards inside taxi cabs were also monitored while driving. Work stress and work hours on typical work days were self-reported. The means of the ambulatory 5-min HR driving and PMHR driving values of the 13 drivers were 80.5 bpm (11.2 bpm higher than their mean HR rest ) and 10.7 % (range, 5.7 to 19.9 %), respectively. The means were lower than the upper limits of ambulatory HR and PMHR for a sustainable 8-hour work (35 bpm above HR rest and 30 % PMHR), although 15-27 % of the 5-min HR driving and PMHR driving values of one driver were higher than the limits. The levels of the five physical hazards among the drivers were modest: temperature (26.4 ± 3.0 °C), relative humidity (40.7 ± 10.4 %), PM 2.5 (21.5 ± 7.9 μg /m 3 ), CO 2 (1,267.1 ± 580.0 ppm) and noise (69.7 ± 3.0 dBA). The drivers worked, on average, 72 h per week and more than half of them reported that their job were often stressful. The impact of physical worksite hazards alone on ambulatory HR of professional taxi drivers in Los Angeles generally appeared to be minor. Future ambulatory heart rate studies including both physical and psychosocial hazards of professional taxi drivers are warranted.
Effects of experiment start time and duration on measurement of standard physiological variables.
Page, Amanda J; Cooper, Christine E; Withers, Philip C
2011-07-01
Duration and start time of respirometry experiments have significant effects on the measurement of basal values for several commonly measured physiological variables (metabolic rate, evaporative water loss and body temperature). A longer measurement duration reduced values for all variables for all start times, and this was an effect of reduced animal activity rather than random sampling. However, there was also an effect of circadian rhythm on the timing of minimal physiological values. Experiment start time had a significant effect on time taken to reach minimal values for all variables, ranging from 0400 hours ± 38 min (body temperature, start time 2300 hours) to 0854 hours ± 52 min (evaporative water loss, start time 1700 hours). It also influenced the time of day that minimal values were obtained, ranging from 2224 hours ± 40 min (carbon dioxide production, start time 1500 hours) to 0600 hours ± 57 min (oxygen consumption, start time 2300 hours), and the minimum values measured. Consequently, both the measurement duration and the experiment start time should be considered in experimental design to account for both a handling and a circadian effect on the animal's physiology. We suggest that experiments to measure standard physiological variables for small diurnal birds should commence between 1700 and 2100 hours, and measurement duration should be at least 9 h.
77 FR 46682 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-06
...: National Oceanic and Atmospheric Administration (NOAA). Title: Pacific Islands Region Coral Reef Ecosystems.... Average Hours per Response: Coral Reef Ecosystem permits, 2 hours; appeals, 3 hours; transshipment permits..., taking, or retaining any Potentially Harvested Coral Reef Taxa (PHCRT) in the coral reef ecosystem...
Soliman, Ahmed M; Anand, Savita Bakhshi; Coyne, Karin S; Castelli-Haley, Jane; Snabes, Michael; Owens, Charlotte D
2017-10-01
To evaluate the impact of uterine fibroid symptoms on employment and household productivity. An online survey of US women between 18 and 54 was conducted. Productivity was assessed using the health related productivity questionnaire (HRPQ). Descriptive statistics and logistic multivariable regressions examined the relationship between uterine fibroids (UF) symptom experience and employment and household productivity. Of 1365 eligible women, 873 (64.0%) were employed. Women lost an average of 0.8 hours to employment-related absenteeism and 4.4 hours due to employment-related presenteeism for 5.1 hours of employment productivity lost/week. Women lost an average of 1.4 hours due to household-related absenteeism and 1.6 hours due to household-related presenteeism for a total of 3.0 hours of household lost productivity. Productivity losses increased with increases in symptom burden. UF has a substantial impact on employment-related and household-related productivity.
NASA Astrophysics Data System (ADS)
Kim, T. W.; Yarnell, S. M.; Yager, E.; Leidman, S. Z.
2015-12-01
Caspar Creek is a gravel-bedded stream located in the Jackson Demonstration State Forest in the coast range of California. The Caspar Creek Experimental Watershed has been actively monitored and studied by the Pacific Southwest Research Station and California Department of Forestry and Fire Protection for over five decades. Although total annual sediment yield has been monitored through time, sediment transport during individual storm events is less certain. At a study site on North Fork Caspar Creek, cross-section averaged sediment flux was collected throughout two storm events in December 2014 and February 2015 to determine if two commonly used sediment transport equations—Meyer-Peter-Müller and Wilcock—approximated observed bedload transport. Cross-section averaged bedload samples were collected approximately every hour during each storm event using a Helley-Smith bedload sampler. Five-minute composite samples were collected at five equally spaced locations along a cross-section and then sieved to half-phi sizes to determine the grain size distribution. The measured sediment flux values varied widely throughout the storm hydrographs and were consistently less than two orders of magnitude in value in comparison to the calculated values. Armored bed conditions, changing hydraulic conditions during each storm and variable sediment supply may have contributed to the observed differences.
Stability, precision, and near-24-hour period of the human circadian pacemaker
NASA Technical Reports Server (NTRS)
Czeisler, C. A.; Duffy, J. F.; Shanahan, T. L.; Brown, E. N.; Mitchell, J. F.; Rimmer, D. W.; Ronda, J. M.; Silva, E. J.; Allan, J. S.; Emens, J. S.;
1999-01-01
Regulation of circadian period in humans was thought to differ from that of other species, with the period of the activity rhythm reported to range from 13 to 65 hours (median 25.2 hours) and the period of the body temperature rhythm reported to average 25 hours in adulthood, and to shorten with age. However, those observations were based on studies of humans exposed to light levels sufficient to confound circadian period estimation. Precise estimation of the periods of the endogenous circadian rhythms of melatonin, core body temperature, and cortisol in healthy young and older individuals living in carefully controlled lighting conditions has now revealed that the intrinsic period of the human circadian pacemaker averages 24.18 hours in both age groups, with a tight distribution consistent with other species. These findings have important implications for understanding the pathophysiology of disrupted sleep in older people.
Effect of overtime work on 24-hour ambulatory blood pressure.
Hayashi, T; Kobayashi, Y; Yamaoka, K; Yano, E
1996-10-01
Recently, the adverse effects of long working hours on the cardiovascular systems of workers in Japan, including "Karoshi" (death from overwork), have been the focus of social concern. However, conventional methods of health checkups are often unable to detect the early signs of such adverse effects. To evaluate the influence of overtime work on the cardiovascular system, we compared 24-hour blood pressure measurements among several groups of male white-collar workers. As a result, for those with normal blood pressure and those with mild hypertension, the 24-hour average blood pressure of the overtime groups was higher than that of the control groups; for those who periodically did overtime work, the 24-hour average blood pressure and heart rate during the busy period increased. These results indicate that the burden on the cardiovascular system of white-collar workers increases with overtime work.
Has the 80-hour work week increased faculty hours?
Winslow, Emily R; Berger, Lisa; Klingensmith, Mary E
2004-01-01
The 80-hour work week has affected not only surgical residents but also faculty. The aim of this study was to determine the effect of resident hour restrictions on faculty hours and attitudes. Anonymous survey. A single, large academic medical center. All faculty in the Departments of Surgery, Neurosurgery, Orthopedics, and Otolaryngology. Faculty were surveyed 6 months before and 6 months after the institution of the resident 80-hour work week. Surgeons detailed hours worked over 1 week and answered yes/no questions about changes in patient care and resident education. P values were determined by Chi-square tests or Student t-tests as appropriate. Of the 118 surveys distributed, 88 were returned (75%). Respondents were evenly divided between general surgeons (GS) and subspecialists (SS). Initially, 70% of faculty predicted that resident work-hour restrictions would increase faculty hours; however, only 47% of faculty felt that this had occurred. When current faculty work hours were compared with previously collected data, no differences were found. Faculty reported working an average of 69.9 +/- 12.2 hours per week this year, compared with 70.4 +/- 12.5 hours last year. When asked about the global impact of the 80-hour work week on faculty, 46% viewed the changes as harmful to the faculty. More concerning, 50% of all faculty felt the care their patients received was worse than previously, with only 2% feeling patient care had improved. This perception was significantly more common among GS faculty (70% GS vs 37% SS; p < 0.01), 94% of whom felt that the current lack of continuity compromises patient care. When the data were stratified by faculty work hours, interesting differences are seen. Of those faculty with work weeks less than 60 hours, only 6% thought the changes were harmful to patients and 64% thought resident training had suffered. In contrast, of those faculty who worked greater than 80 hours per week, 56% thought patients were harmed (p = 0.03) and 100% thought training had suffered (p < 0.01). Faculty work hours have not increased in the 6 months after the institution of the 80-hour resident work week. However, the majority of the faculty feels that both patient care and resident education have deteriorated.
Assessment of TMY generation methods for solar power production estimation
NASA Astrophysics Data System (ADS)
Zebner, H.
2010-09-01
This paper deals with the evaluation of different methods commonly employed in the solar power industry for the generation of representative data sets with solar resource information and further climate parameters. The quality of energy yield simulation data sets is defined by the accuracy of the data source (e. g. measurement device or calculation model) and its representativeness for the typical meteorological conditions at the location of the investigated power plant site. Supposing that data with high accuracy is available the next challenge is to prepare a best-possible input data set for the energy production simulation software. Such programs are often limited to the simulation of one-year data sets with hourly frequency (i. e. 8760 values). The data set shall therefore contain values which are most representative for each hour of the year and reflect the dynamical behaviour of the resource. As simple averaging of long-term data would not fulfil these requirements, certain methods for selecting such a typical meteorological year (TMY) have been developed in recent years. Presently, there are three to four different methods recommended in scientific literature or suggested by practitioners in the solar industry. The evaluation in this paper seeks to test the most commonly used methods with high precision data from the baseline surface radiation network (BSRN). From a long-term time series retrieved from a station in a region suitable for the development of solar power plants a TMY is created by utilizing different generation methods. The resulting data set is then compared to the average over all years in order to evaluate the general representativeness. As the plant operator is interested in the average production over the life time of a plant the result of an energy yield simulation performed with each of the different data set is then compared to the mean production gained by simulating the yield of for each single year and then averaging the results obtained for the individual years. As outcome of this evaluation information on the meteorological representativeness and suitability for energy production estimation of each method is achieved. This is regarded as an important step in assuring the validity of production forecasts based on TMYs in the context of solar power plant development - an area which is characterised by very specific needs for solar input values (e. g. DNI) and lack in the concurrent availability of additional parameters such as temperature and humidity.
Kyo, S; Miyamoto, N; Yokote, Y; Ueda, K; Takamoto, S; Omoto, R
1996-06-01
Complete rupture of a papillary muscle following acute myocardial infarction is a severe complication that is typically associated with acute left ventricular failure, pulmonary edema, and relentless clinical deterioration. The reported mortality rates without surgical intervention is almost 90%, therefore, prompt operation without prolonged attempts at medical stabilization is the key to decrease operative mortality. Although the complete coronary revascularization in conjunction with mitral valve replacement is advocated in the western medical academic society, there is only a few case of conjunct surgery has been reported in Japan. Three successful cases of conjunct surgery of mitral valve replacement and coronary complete revascularization in acute phase within one week from the onset of acute myocardial infarction (AMI) are described. There were one male and two female patients with an average age of 60-year-old (range 48-67), who developed cardiogenic shock and admitted to our hospital. The average interval between onset of AMI and the appearance of mitral regurgitation (MR) was 38 hours, and that of the appearance of MR and admission was 40 hours. Surgeries were performed within 26 hours (average 13 hours) after admission. The mitral valve was replaced with a mechanical valve (St. Jude Medical Valve) and a complete coronary revasculatization was done using saphenous vein graft. The average period of operation time and aortic cross clamping time were 6 hours 22 minutes and 109 minutes respectively. The average number of coronary grafting was 2.3 (range 1-3). Postoperative recovery from cardiogenic shock was uneventful in all three patients. The average periods of ICU stay and hospital stay were 5 days and 43 days respectively. All patients have regained their social activities with mean follow up period of 52 months. Since ischemic heart disease remains the leading cause of death in such patients, it is suggested that complete coronary revascularization should be performed immediately in conjunction with valve replacement even in the acute phase after onset of AMI.
Fields, Ryan C; Bowman, Michele C; Freeman, Bradley D; Klingensmith, Mary E
2009-01-01
Residency programs have been forced to curtail many educational activities to comply with duty-hour restrictions. We describe an "after hours" educational program as a forum to provide small-group education customized for each training level to compliment our formal curriculum. Sessions within each general surgery specialty were organized such that 1 session each month was open to either junior (R1 and R2) or senior (R3-R5) trainees and hosted by surgical faculty. Attendance was optional and limited to 15 residents per session with the format determined by the hosting faculty. Participants completed a postsession survey. Fourteen sessions were held during the 2008-2009 academic year. All sessions were >90% subscribed within 1 week of announcement and attendance was 88%. The average session duration was 2.6 +/- 0.4 hours. Junior resident sessions focused on preparing R1 and R2 residents to handle common consult questions; senior resident sessions were modeled as "mock oral boards." Resident and faculty responses to the postsession questionnaire were similar and favorable with respect to the educational value of this format. There is enthusiasm among faculty and trainees to provide small-group, level-specific educational programs outside of the hospital setting and the 80-hour workweek. Such a program is easily implemented, highly effective, and well received. This format has the added benefit of improving interaction between faculty and residents and increasing the camaraderie of a surgical training program.
Predictive power of the DASA-IV: Variations in rating method and timescales.
Nqwaku, Mphindisi; Draycott, Simon; Aldridge-Waddon, Luke; Bush, Emma-Louise; Tsirimokou, Alexandra; Jones, Dominic; Puzzo, Ignazio
2018-05-10
This project evaluated the predictive validity of the Dynamic Appraisal of Situational Aggression - Inpatient Version (DASA-IV) in a high-secure psychiatric hospital in the UK over 24 hours and over a single nursing shift. DASA-IV scores from three sequential nursing shifts over a 24-hour period were compared with the mean (average of three scores across the 24-hour period) and peak (highest of the three scores across the 24-hour period) scores across these shifts. In addition, scores from a single nursing shift were used to predict aggressive incidents over each of the following three shifts. The DASA-IV was completed by nursing staff during handover meetings, rating 43 male psychiatric inpatients over a period of 6 months. Data were compared to incident reports recorded over the same period. Receiver operating characteristic (ROC) curves and generalized estimating equations assessed the predictive ability of various DASA-IV scores over 24-hour and single-shift timescales. Scores from the DASA-IV based on a single shift had moderate predictive ability for aggressive incidents occurring the next calendar day, whereas scores based on all three shifts had excellent predictive ability. DASA-IV scores from a single shift showed moderate predictive ability for each of the following three shifts. The DASA-IV has excellent predictive ability for aggressive incidents within a secure setting when data are summarized over a 24-hour period, as opposed to when a single rating is taken. In addition, it has moderate value for predicting incidents over even shorter timescales. © 2018 Australian College of Mental Health Nurses Inc.
Solute transport and storage mechanisms in wetlands of the Everglades, south Florida
Harvey, Judson W.; Saiers, James E.; Newlin, Jessica T.
2005-01-01
Solute transport and storage processes in wetlands play an important role in biogeochemical cycling and in wetland water quality functions. In the wetlands of the Everglades, there are few data or guidelines to characterize transport through the heterogeneous flow environment. Our goal was to conduct a tracer study to help quantify solute exchange between the relatively fast flowing water in the open part of the water column and much more slowly moving water in thick floating vegetation and in the pore water of the underlying peat. We performed a tracer experiment that consisted of a constant‐rate injection of a sodium bromide (NaBr) solution for 22 hours into a 3 m wide, open‐ended flume channel in Everglades National Park. Arrival of the bromide tracer was monitored at an array of surface water and subsurface samplers for 48 hours at a distance of 6.8 m downstream of the injection. A one‐dimensional transport model was used in combination with an optimization code to identify the values of transport parameters that best explained the tracer observations. Parameters included dimensions and mass transfer coefficients describing exchange with both short (hours) and longer (tens of hours) storage zones as well as the average rates of advection and longitudinal dispersion in the open part of the water column (referred to as the “main flow zone”). Comparison with a more detailed set of tracer measurements tested how well the model's storage zones approximated the average characteristics of tracer movement into and out of the layer of thick floating vegetation and the pore water in the underlying peat. The rate at which the relatively fast moving water in the open water column was exchanged with slowly moving water in the layer of floating vegetation and in sediment pore water amounted to 50 and 3% h−1, respectively. Storage processes decreased the depth‐averaged velocity of surface water by 50% relative to the water velocity in the open part of the water column. As a result, flow measurements made with other methods that only work in the open part of the water column (e.g., acoustic Doppler) would have overestimated the true depth‐averaged velocity by a factor of 2. We hypothesize that solute exchange and storage in zones of floating vegetation and peat pore water increase contact time of solutes with biogeochemically active surfaces in this heterogeneous wetland environment.
Huang, Alison J; Cummings, Steven R; Schembri, Michael; Vittinghoff, Eric; Ganz, Peter; Grady, Deborah
2016-03-01
To describe the efficacy and tolerability of continuous nitroglycerin for treatment of hot flashes. Perimenopausal and postmenopausal women reporting at least seven hot flashes per day were recruited into a single-arm, dose-escalation trial of continuous transdermal nitroglycerin. Participants were started on a generic 0.1 mg/hour nitroglycerin patch applied daily without patch-free periods. During 4 weeks, participants escalated dosage weekly to 0.2, 0.4, or 0.6 mg/hour as tolerated, then discontinued nitroglycerin during the final week. Changes in hot flash frequency and severity were assessed using symptom diaries. Paired t tests examined change in outcomes between baseline and maximal-dose therapy and after discontinuation of nitroglycerin. Of the 19 participants, mean age was 51.4 (±4.3) years. Women reported an average 10.6 (±3.0) hot flashes and 7.1 (±3.8) moderate-to-severe hot flashes per day at baseline. Eleven women escalated to 0.6 mg/hour, three to 0.4 mg/hour, two to 0.2 mg/hour, and one remained on 0.1 mg/hour nitroglycerin. Two discontinued nitroglycerin before the first outcomes assessment. Among the remaining 17 women, the average daily frequency of hot flashes decreased by 54% and the average frequency of moderate-to-severe hot flashes decreased by 69% from baseline to maximum-dose therapy (P < 0.001 for both). After discontinuing nitroglycerin, participants reported an average 23% increase in frequency of any hot flashes (P = 0.041) and 96% increase in moderate-to-severe hot flashes (P < 0.001). Continuous nitroglycerin may substantially and reversibly decrease hot flash frequency and severity. If confirmed in a randomized blinded trial, it may offer a novel nonhormonal hot flash treatment.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-03
... metered load settled using WACM hourly pricing with no using WACM hourly pricing with no penalty. penalty... metered load settled using pricing in no-penalty band. Customer WACM hourly pricing with a 25% penalty... or equal to 0.5 percent of its hourly average load, no Regulation Service charges will be assessed by...
76 FR 50186 - Submission for OMB Emergency Review
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... (ICR) to the Office of Management and Budget (OMB) for review and clearance in accordance with the.... Agency Number: None. Affected Public: Nonprofit organizations and congregations. Total Respondents: 600. Frequency: One time. Average Time per Response: 40 hours. Estimated Total Burden Hours: 24,000 hours. Total...
Holbek, Bo Laksáfoss; Petersen, René Horsleben; Kehlet, Henrik
2017-01-01
The objective of this study was to evaluate the potential of predicting the pleural fluid output in patients after video-assisted thoracoscopic lobectomy of the lung. Detailed measurements of continuous fluid output were obtained prospectively using an electronic thoracic drainage device (Thopaz+™, Medela AG, Switzerland). Patients were divided into high (≥500 mL) and low (<500 mL) 24-hour fluid output, and detailed flow curves were plotted graphically to identify arithmetic patterns predicting fluid output in the early (≤24 hours) and later (24–48 hours) post-operative phase. Furthermore, multiple logistic regression analysis was used to predict high 24-hour fluid output using baseline data. Data were obtained from 50 patients, where 52% had a fluid output of <500 mL/24 hours. From visual assessment of flow curves, patients were grouped according to fluid output 6 hours postoperatively. An output ≥200 mL/6 hours was predictive of ‘high 24-hour fluid output’ (P<0.0001). However, 33% of patients with <200 mL/6 hours ended with a ‘high 24-hour fluid output’. Baseline data showed no predictive value of fluid production, and 24-hour fluid output had no predictive value of fluid output between 24 and 48 hours. Assessment of initial fluid production may predict high 24-hour fluid output (≥500 mL) but seems to lack clinical value in drain removal criteria. PMID:28840021
NASA Astrophysics Data System (ADS)
Nelson, M.; Dempster, W. F.; Silverstone, S.; Alling, A.; Allen, J. P.; van Thillo, M.
Two crop growth experiments in the soil-based closed ecological facity, Laboratory Biosphere, were conducted from 2003-2004 with candidate space life support crops. Apogee wheat (Utah State University variety) was grown, planted in 2 densities, 400 and 800 seeds m-2. The lighting regime for the wheat crop was 16 hours of light -- 8 hours dark at a total light intensity of around 840 mol m2 sec-1 and 48.4 mol m-2 d-1 over 84 days Average biomass was 1395 g m-2, 16.0 g m-2 day-1 and average seed production was 689 g m-2 and 7.9 g m2 day-1. The less densely planted side was more productive than the denser planting, with 1634 g m-2 and 18.8g m-2 day-1 of biomass vs. 1156 g m-2 and 13.3 g m-2 day-1; and a seed harvest of 812.3 g m-2 and 9.3 g m-2 day-1 vs. 566.5 g m-2 and 6.5 g m-2 day-1 Harvest index was 0.49 for the wheat crop. The experiment with sweet potato used TU-82-155, a compact variety developed at Tuskegee University. Light during the sweet potato experiment, on a 16 hour on/8 hours dark cycle, totalled 5568 total moles of light in 126 days for the sweet potatoes, or an average of 44.2 moles m-2 day-1. Temperature regime was 28 deg +/- 3 deg C day /22 deg +/- 4 deg C night. Sweet potato tuber yield was 39.7 kg wet weight, or an average of 7.4 kg m-2 and 7.7 kg dry weight of tubers since dry weight was about 18.6% wet weight.^Average per day production was 58.7 g m-2 day-1 wet weight and 11.3 g m-2 day-1. For the wheat, average light efficiency was 0.34 grams biomass per mole, and 0.17 grams seed per mole. The best area of wheat had an efficiency of light utilization of 0.51 g biomass per mole and 0.22 g seed per mole. For the sweet potato crop, light efficiency per tuber wet weight was 7.13 g/mole and 1.38 g dry weight of tuber per mole of light. The best area of tuber production had 9.49 g/mole wet weight and 1.85 g/mole of light dry weight. Production from the wheat was The Laboratory Biosphere experiment's light efficiency was somewhat higher than the USU field results but somewhat below greenhouse trials at comparable light levels, and the best portion of the crop at 0.22g/mole was inbetween those values. Sweet potato production was overall close to 50% higher than trials using hydroponic methods with TU-82-155 at NASA JSC. Compared to projected yields for the Mars on Earth life support system, these wheat yields were about 15% higher, and the sweet potato yields averaged over 80% higher
Paul, David R; Kramer, Matthew; Stote, Kim S; Spears, Karen E; Moshfegh, Alanna J; Baer, David J; Rumpler, William V
2008-06-09
Activity monitors (AM) are small, electronic devices used to quantify the amount and intensity of physical activity (PA). Unfortunately, it has been demonstrated that data loss that occurs when AMs are not worn by subjects (removals during sleeping and waking hours) tend to result in biased estimates of PA and total energy expenditure (TEE). No study has reported the degree of data loss in a large study of adults, and/or the degree to which the estimates of PA and TEE are affected. Also, no study in adults has proposed a methodology to minimize the effects of AM removals. Adherence estimates were generated from a pool of 524 women and men that wore AMs for 13 - 15 consecutive days. To simulate the effect of data loss due to AM removal, a reference dataset was first compiled from a subset consisting of 35 highly adherent subjects (24 HR; minimum of 20 hrs/day for seven consecutive days). AM removals were then simulated during sleep and between one and ten waking hours using this 24 HR dataset. Differences in the mean values for PA and TEE between the 24 HR reference dataset and the different simulations were compared using paired t-tests and/or coefficients of variation. The estimated average adherence of the pool of 524 subjects was 15.8 +/- 3.4 hrs/day for approximately 11.7 +/- 2.0 days. Simulated data loss due to AM removals during sleeping hours in the 24 HR database (n = 35), resulted in biased estimates of PA (p < 0.05), but not TEE. Losing as little as one hour of data from the 24 HR dataset during waking hours results in significant biases (p < 0.0001) and variability (coefficients of variation between 7 and 21%) in the estimates of PA. Inserting a constant value for sleep and imputing estimates for missing data during waking hours significantly improved the estimates of PA. Although estimated adherence was good, measurements of PA can be improved by relatively simple imputation of missing AM data.
Anesthesia for left ventricular assist device insertion: a case series and review.
Broussard, David; Donaldson, Emilie; Falterman, Jason; Bates, Michael
2011-01-01
From October 2008 to June 2010, a total of 42 patients had the HeartMate II left ventricular assist device inserted surgically at Ochsner Medical Center in New Orleans, LA. A retrospective electronic record review was conducted on this series of patients to analyze elements of perioperative anesthetic care, including general anesthetic care, echocardiographic considerations, and blood product usage. Etomidate was used to induce anesthesia for 34 of 42 patients (81%) in this series, with an average dose of 16.5 mg (±6 mg). The average intraoperative fentanyl dose was 1,318 µg (±631 µg). On average, patients were extubated 91 hours (±72 hours) after arrival to the intensive care unit and left on day 9 (±5 days). The average left ventricular ejection fraction of the patients in this series was 13% (±5%). Sixteen patients were evaluated as having severe right-heart dysfunction preoperatively. Two of 42 patients required surgical closure of echocardiographically identified patent foramen ovale. Twelve of 42 patients underwent surgical correction of tricuspid regurgitation. On average, 3 units (±2.6 units) of fresh frozen plasma were transfused intraoperatively and 10 units postoperatively. Intraoperative red blood cell usage averaged 1.1 units (maximum, 7 units), with an average 9.3 units administered in the first 48 hours postoperatively.
Dental hygienists in Israel: employment evaluation, job satisfaction, and training implications.
Yavnai, Nirit; Bilder, Leon; Sgan-Cohen, Harold; Zini, Avi
2012-10-01
Fundamental changes have occurred in dental services for children in Israel that are likely to affect workforce needs for dental hygienists. The aim of this study was to describe the employment situation and job satisfaction of a sample of dental hygienists in Israel, to estimate associated variables, and to discuss corresponding possible implications for training programs after these changes. An e-mailed questionnaire sent to all dental hygienists in the Israeli Dental Hygienists Association list included questions about respondents' demographic background, years of experience, working hours, desire to work in an alternative occupation, and sense that they were valued within the dental community. The response rate was 20.7 percent. The responses showed that dental hygienists worked, on average, in 2.11 different working venues, 23.64 hours/week, and 12.34 hours in the private sector. Almost 63 percent of the respondents were willing to add working hours as a dental hygienist, preferably in the private sector. Also, 38.2 percent of the respondents worked in an extra non-dental hygienist job (mean=7.05 hours/week). These dental hygienists reported a high level of job satisfaction. After regression analysis, a high number of working venues, years of experience, and hypothetically choosing again to be a dental hygienist were found to be significant indicators of job satisfaction (R(2)=0.491). It is important that dental hygienists be satisfied and willing to expand their activities. Legislative changes may require reorientation and refocusing of dental hygiene education programs.
Occupational burnout levels in emergency medicine--a nationwide study and analysis.
Popa, Florian; Raed, Arafat; Purcarea, Victor Lorin; Lală, Adrian; Bobirnac, George
2010-01-01
The specificity of the emergency medical act strongly manifests itself on account of a wide series of psycho-traumatizing factors augmented both by the vulnerable situation of the patient and the paroxysmal state of the act. Also, it has been recognized that the physical solicitation and distress levels are the highest among all medical specialties, this being a valuable marker for establishing the quality of the medical act. We have surveyed a total of 4725 emergency medical workers with the MBI-HSS instrument, receiving 4693 valid surveys (99.32% response rate). Professional categories included Emergency Department doctors (M-EMD), ambulance doctors (M-AMB), ED doctors with field work in emergency and resuscitation (including mobile intensive care units and airborne intensive care units) (D-SMU), medical nurses in Emergency Departments (N-EMD), medical nurses in the ambulance service (N-AMB), ED medical nurses with field activity in emergency and resuscitation (N-SMU), ambulance drivers (DRV) and paramedic (EMT). The n values for every category of subjects and percentage of system coverage (table 3) shows that we have covered an estimated total of 29.94% of the Romanian emergency medical field workers. MBI-HSS results show a moderate to high level of occupational stress for the surveyed subjects. The average values for the three parameters, corresponding to the entire Romanian emergency medical field were 1.41 for EE, 0.99 for DP and 4.47 for PA (95% CI). Average results stratified by professional category show higher EE average values (v) for the M-SMU (v=2.01, 95%CI) and M-EMD (v=2.21, 95% CI) groups corresponding to higher DP values for the same groups (vM-EMD=1.41 and vM-SMU=1.22, 95% CI). PA values for these groups are below average, corresponding to an increased risk factor for high degrees of burnout. Calculated PA values are 4.30 for the M-EMD group and 4.20 for the M-SMU group. Of all surveyed groups, our study shows a high risk of burnout consisting of high emotional exhaustion (EE) and high depersonalization (DP) values for Emergency Department doctors, Emergency, and Resuscitation Service doctors (M-SMU). Possible explanations for this might be linked to high patient flow, Emergency Department crowding, long work hours and individual parameters such as coping mechanisms, social development and work environment.
Historical trends in chill hour accumulation and peach bud response to hydrogen cyanamide
USDA-ARS?s Scientific Manuscript database
Long held records for (low) chill hour accumulation have recently been broken several times in the southeastern US peach (Prunus persica) production areas. Long term historical average chill hour accumulation through February 15th in middle Georgia has dropped significantly over the last 15 years. T...
78 FR 47317 - Agency Information Collection Activities; Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-05
... availability of warranty terms and minimum standards for informal dispute settlement mechanisms that are...--requires a mix of legal analysis (50%), legal support (paralegals) (25%) and clerical help (25%). Staff estimates that half of the total burden hours (58,064 hours) requires legal analysis at an average hourly...
76 FR 42678 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... collection). Burden Hours: 250. Number of Respondents: 100 (15 cell line limit). Average Hours per Response: 2 hours and 30 minutes (10 minutes/cell line x 15 cell lines). Needs and Uses: The NIST Biochemical...: National Institute of Standards and Technology (NIST) Title: Identification of Human Cell Lines Project...
78 FR 56842 - Arbitrage Restrictions on Tax-Exempt Bonds
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... working capital. This accounting rule recognizes that sources of funds are fungible and treats bond..., DC 20044. Submissions may be hand delivered to: CC:PA:LPD:PR Monday through Friday between the hours.... Estimated total annual recordkeeping burden: 232 hours. Estimated average annual burden hours per respondent...
Yamaguchi, Yoshie
2010-01-01
The purpose of this study was to identify the current status of operations at community general support centers which provide coordination for elderly care and the correlation of personal traits, work environment and the occupational stress of the staff. Subjects of the study were 251 staff members of community general support centers. The current status of operations at the community general support centers and the personal traits, work environment, effort-remuneration imbalance model (ERI) and general health questionnaire (GHQ) were surveyed. The initial analysis involved a comparison by a chi-square test on: The effort-remuneration ratio (E/R ratio) of personal traits and work environment, risk of over-commitment (OC), and GHQ score. To explore the correlation between the E/R ratio of the three GHQ groups (low, middle and high score groups) and the OC value, one-way analysis of variance was performed. Out of the four basic functions of the community general support centers, 22.0% of the respondents noted that "establishment of a regional, comprehensive/multi-tiered service network" was functioning, and 50.4% of respondents noted that "comprehensive and continuous care management" was functioning. The average effort score was 15.5 +/- 5.3, approximately double the average value of preceding studies. Significant differences found in GHQ scores were related to working hours (p<0.001) and anxiety was related to task content (p<0.001). Moreover, a higher GHQ score was accompanied by a higher E/R ratio and as a result of the multiple comparison, a marked difference was observed between the GHQ low score group and the GHQ high score group (p<0.001), and a significant difference was also found between the GHQ low score group and GHQ medium score group (p=0.012). Items observed to have significant correlation with high E/R ratio were: "Weekly working hours of 50 h or more" (OR: 10.38, 95% CI: 2.52-42.70), "Unstable employment" (OR: 2.75, 95% CI: 1.22-6.21) and "Anxiety related to task content" (OR: 17.04, 95% CI: 3.57-81.24). Items observed to have significant correlation with OC value risk factors were: "Weekly working hours of 50 h or more" (OR: 8.04, 95% CI: 1.99-32.41) and "Anxiety related to task content" (OR: 4.60, 95% CI: 2.04-10.37). We conclude that the basic functions of the community general support centers are not presently very functional. The stress levels of the community general support center staff are high and their health levels are low. This indicates that staff are forced to work with anxiety related to task content under conditions of poor pay and long working hours.
Association between Physical Inactivity and Academic Record in Korean Adolescents
Shin, Yi-Soo; So, Wi-Young
2012-01-01
Background: The purpose of this study was to investigate the association between physical inactivity and academic record in Korean adolescents. Methods: Adolescent students from the first grade of middle school to the third grade of high school (n=75,066) participated in the 5th Korea Youth Risk Behavior Web-based Survey project in 2009. The association between physical inactivity and academic record was assessed using multivariate logistic regression analysis after adjusting for gender, age, body mass index, family’s socioeconomic status, parents’ education level, and frequency of vigorous or moderate physical activity (PA) as well as muscular strength exercises. Results: During weekdays, the odds ratios (ORs) (95% confidence interval [CI]) for reporting a higher than average academic record, as compared with <1 hour of physical inactivity per day, was 0.796 (0.761–0.832, for ≥1 to <2 hours, 0.632 (0.603–0.663, for ≥2 to <3 hours, 0.567 (0.535–0.601, for ≥3 to <4 hours, and 0.494 (0.468–0.522, P < 0.001 for all cases) for ≥4 hours of physical inactivity per day. During the weekends, the ORs (95% CI) for reporting a higher than average academic record, as compared with <1 hour of physical inactivity per day, were 0.901 (0.848–0.957, P = 0.001) for ≥3 to <4 hours and 0.785 (0.743–0.830, P < 0.001) for ≥4 hours of physical inactivity per day. Conclusion: Korean adolescents who spend more time engaged in physical inactivity are predisposed to a below-average academic record. PMID:23308350
Sunlight Exposure, Work Hours, Caffeine Consumption, and Sleep Duration in the Naval Environment.
Shattuck, Nita L; Matsangas, Panagiotis
2017-06-01
Sailors in the U.S. Navy are habitual shiftworkers, often experiencing circadian misalignment due to their irregular work/rest schedules. This study assessed the effect of sunlight exposure, work hours, and caffeinated beverage consumption on the daily sleep duration of crewmembers of a U.S. Navy ship during a 2-wk underway period. Working in an artificially lit area with no access to sunlight during work hours, U.S. Navy crew members (N = 91) used daily logs to report their daily activity, caffeinated beverage consumption, and exposure to sunlight while off-duty; sleep was assessed by wrist-worn actigraphy. Hours of sunlight exposure, work duration, and the amount of coffee/tea/soft drinks were statistically significant predictors of sleep duration. On average, crewmembers who reported more than one half-hour of sunlight each day slept on average ∼40 min (10%) less than their peers working the same shifts who received less than one half-hour of sunlight (on average 6.05 ± 0.90 h vs. 6.71 ± 0.91 h, respectively). Exposure to sunlight, work hours, and consumption of caffeinated beverages are important factors when planning watchstanding schedules at sea. Even though further research is needed, our results suggest that even brief exposure to sunlight may contribute to circadian misalignment that negatively affects sleep in the operational environment. Educating crewmembers about sleep hygiene, especially the important roles played by sunlight and caffeine, could potentially improve the sleep and fatigue levels of this population of maritime shiftworkers.Shattuck NL, Matsangas P. Sunlight exposure, work hours, caffeine consumption, and sleep duration in the naval environment. Aerosp Med Hum Perform. 2017; 88(6):579-585.
NASA Astrophysics Data System (ADS)
Bernardi, A.; Fraser-Smith, A. C.; Villard, O. G.
1985-02-01
An index of geomagnetic activity in the upper part of the ultra low frequency (ULF) range (less than 4.55 Hz) has been developed. This index will be referred to as the MA index (magnetic activity index). The MA index is prepared every half hour and is a measure of the strength of the geomagnetic activity in the Pc1-Pc3 pulsation frequency range during that half hour period. Activity in the individual Pc pulsation ranges can also be measured, if desired. The index is calculated from the running average of the full-wave rectified values of the band pass filtered geomagnetic signals and thus it provides a better indication of the magnitude of these band pass filtered magnetic pulsations than does the ap index, for example. Daily variations of the band pass filtered magnetic signals are also better captured by the MA index. To test this system we used analog tape recordings of wide-band geomagnetic signals. The indices for these tapes are presented in the form of plots, together with a comparison with the ap indices of the same time intervals. The MA index shows the daily variation of the geometric signals quite clearly during times when there is strong activity, i.e., when the ap index values are large. Because impulsive signals, such as lightning discharges, tend to be suppressed in the averaging process, the MA index is insensitive to impulsive noise. It is found that the time variation of the MA index is in general markedly different from the variation of the ap index for the same time intervals.
Risk analysis of tractor overturns on catfish farms.
Stephens, Walter B; Ibendahl, Gregory A; Myers, Melvin L; Cole, Henry P
2010-10-01
Fatal and nonfatal injuries occur on catfish farms as a result of tractor overturns, but these injuries can be greatly mitigated when a tractor is equipped with a rollover protective structure (ROPS) and seatbelt. This study analyzed the proportion of tractors on catfish farms in Mississippi not equipped with ROPS and the cost of retrofitting those tractors with a ROPS and seatbelt as compared to the expected benefits gained from adding the protection. To determine if farmers have the financial incentive to retrofit older tractors, a net present value framework was used because the expected benefits occur over a number of years. The ROPS retrofit is a one-time cost that occurs immediately, and thus the present value does not need to be calculated, i.e., time period 0. According to this study adding ROPS will provide a net benefit of $22,877 in the event of an overturn. When dealing with small farms (<125 acres) where an average tractor is used for approximately twice as many hours compared to an average tractor on large farms, the extra hours worked by a single tractor resulted in total benefits of retrofitting ROPS of $9.45 per year, whereas for large farms the net benefit is $4.70 (=125 acres). Given that the least expensive retrofit is $147, it would take 15.5 years of tractor use on the small farms for the expected benefits to outweigh the cost. Given the large range of costs that could occur due to an overturn, there could be a significant premium for not having ROPS protection. In other words, there likely is a smaller range of costs from an overturn with ROPS than without ROPS because ROPS reduces the more serious incidents.
CIACCIO, EDWARD J.; BIVIANO, ANGELO B.; GAMBHIR, ALOK; EINSTEIN, ANDREW J.; GARAN, HASAN
2014-01-01
Background When atrial fibrillation (AF) is incessant, imaging during a prolonged ventricular RR interval may improve image quality. It was hypothesized that long RR intervals could be predicted from preceding RR values. Methods From the PhysioNet database, electrocardiogram RR intervals were obtained from 74 persistent AF patients. An RR interval lengthened by at least 250 ms beyond the immediately preceding RR interval (termed T0 and T1, respectively) was considered prolonged. A two-parameter scatterplot was used to predict the occurrence of a prolonged interval T0. The scatterplot parameters were: (1) RR variability (RRv) estimated as the average second derivative from 10 previous pairs of RR differences, T13–T2, and (2) Tm–T1, the difference between Tm, the mean from T13 to T2, and T1. For each patient, scatterplots were constructed using preliminary data from the first hour. The ranges of parameters 1 and 2 were adjusted to maximize the proportion of prolonged RR intervals within range. These constraints were used for prediction of prolonged RR in test data collected during the second hour. Results The mean prolonged event was 1.0 seconds in duration. Actual prolonged events were identified with a mean positive predictive value (PPV) of 80% in the test set. PPV was >80% in 36 of 74 patients. An average of 10.8 prolonged RR intervals per 60 minutes was correctly identified. Conclusions A method was developed to predict prolonged RR intervals using two parameters and prior statistical sampling for each patient. This or similar methodology may help improve cardiac imaging in many longstanding persistent AF patients. PMID:23998759
New Approach To Hour-By-Hour Weather Forecast
NASA Astrophysics Data System (ADS)
Liao, Q. Q.; Wang, B.
2017-12-01
Fine hourly forecast in single station weather forecast is required in many human production and life application situations. Most previous MOS (Model Output Statistics) which used a linear regression model are hard to solve nonlinear natures of the weather prediction and forecast accuracy has not been sufficient at high temporal resolution. This study is to predict the future meteorological elements including temperature, precipitation, relative humidity and wind speed in a local region over a relatively short period of time at hourly level. By means of hour-to-hour NWP (Numeral Weather Prediction)meteorological field from Forcastio (https://darksky.net/dev/docs/forecast) and real-time instrumental observation including 29 stations in Yunnan and 3 stations in Tianjin of China from June to October 2016, predictions are made of the 24-hour hour-by-hour ahead. This study presents an ensemble approach to combine the information of instrumental observation itself and NWP. Use autoregressive-moving-average (ARMA) model to predict future values of the observation time series. Put newest NWP products into the equations derived from the multiple linear regression MOS technique. Handle residual series of MOS outputs with autoregressive (AR) model for the linear property presented in time series. Due to the complexity of non-linear property of atmospheric flow, support vector machine (SVM) is also introduced . Therefore basic data quality control and cross validation makes it able to optimize the model function parameters , and do 24 hours ahead residual reduction with AR/SVM model. Results show that AR model technique is better than corresponding multi-variant MOS regression method especially at the early 4 hours when the predictor is temperature. MOS-AR combined model which is comparable to MOS-SVM model outperform than MOS. Both of their root mean square error and correlation coefficients for 2 m temperature are reduced to 1.6 degree Celsius and 0.91 respectively. The forecast accuracy of 24- hour forecast deviation no more than 2 degree Celsius is 78.75 % for MOS-AR model and 81.23 % for AR model.
Stojkov, Svetlana; Tadić, Ivana; Crnjanski, Tatjana; Krajnović, Dušanka
2016-09-01
Pharmacists' competence represents a dynamic framework of knowledge, skills and abilities to carry out tasks, and it reflects on improving the quality of life and on patients’ health. One of the documents for the Evaluation and Competency Development of Pharmacists is the Global Competency Framework (GbCF). The aim of this study was to implement the GBCF document into Serbian pharmacies, to perform assessment and self assessment of the competencies. The assessment and self-assessment of pharmacists’ competencies were performed during the period 2012−13 year in eight community pharmacy chains, in seven cities in Serbia. For assessment and self-assessment of pharmacists competencies the GbCF model was applied, which was adjusted to pharmaceutical practice and legislation in Serbia. External assessment was conducted by teams of pharmacists using the structured observation of the work of pharmacists during regular working hours. Evaluated pharmacists filled out the questionnaire about demographic indicators about the pharmacist and the pharmacy where they work. A total of 123 pharmacists were evaluated. Pharmacists’ Professional Competency Cluster (KK1) had the lowest score (average value 2.98), while the cluster Management and Organizational Competency (KK2) had the highest score (average value 3.15). The competence Recognition of the Diagnosis and Patient Counseling (K8), which belonged to the cluster KK1, had the lowest score (average value for assessment and self-assessment were 2.09, and 2.34, respectively) among the all evaluated competencies. GbCF might be considered as an instrument for the competencies' evaluation/selfevaluation and their improvement, accordingly.
Villarreal, Monica C; Rostad, Bradley S; Wright, Richard; Applegate, Kimberly E
2015-12-01
To identify and reduce reasons for delays in procedure start times, particularly the first cases of the day, within the interventional radiology (IR) divisions of the Department of Radiology using principles of continuous quality improvement. An interdisciplinary team representative of the IR and preprocedure/postprocedure care area (PPCA) health care personnel, managers, and data analysts was formed. A standardized form was used to document both inpatient and outpatient progress through the PPCA and IR workflow in six rooms and to document reasons for delays. Data generated were used to identify key problems areas, implement improvement interventions, and monitor their effects. Project duration was 6 months. The average number of on-time starts for the first case of the day increased from 23% to 56% (P value < .01). The average number of on-time, scheduled outpatients increased from 30% to 45% (P value < .01). Patient wait time to arrive at treatment room once they were ready for their procedure was reduced on average by 10 minutes (P value < .01). Patient care delay duration per 100 patients was reduced from 30.3 to 21.6 hours (29% reduction). Number of patient care delays per 100 patients was reduced from 46.6 to 40.1 (17% reduction). Top reasons for delay included waiting for consent (26% of delays duration) and laboratory tests (12%). Many complex factors contribute to procedure start time delays within an IR practice. A data-driven and patient-centered, interdisciplinary team approach was effective in reducing delays in IR. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Regional And Seasonal Aspects Of Within-The-Hour Tec Statistics
NASA Astrophysics Data System (ADS)
Koroglu, Ozan; Arikan, Feza; Koroglu, Meltem
2015-04-01
Ionosphere is one of the atmosphere layers which has a plasma structure. Several mechanisms originating from both space and earth itself governs this plasma layer such as solar radiation and geomagnetic effects. Ionosphere plays important role for HF and satellite communication, and space based positioning systems. Therefore, the determination of statistical behavior of ionosphere has utmost importance. The variability of the ionosphere has complex spatio-temporal characteristics, which depends on solar, geomagnetic, gravitational and seismic activities. Total Electron Content (TEC) is one of the major observables for investigating and determining this variability. In this study, spatio-temporal within-the-hour statistical behavior of TEC is determined for Turkey, which is located in mid-latitude, using the TEC estimates from Turkish National Permanent GPS Network (TNPGN)-Active between the years 2009 and 2012. TEC estimates are obtained as IONOLAB-TEC which is developed by IONOLAB group (www.ionolab.org) from Hacettepe University. IONOLAB-TEC for each station in TNPGN-Active is organized in a database and grouped with respect to years, ionospheric seasons, hours and regions 2 degree by 3 degree, in latitude and longitude, respectively. The data sets are used to calculate within-the-hour parametric Probability Density Functions (PDF). For every year, every region and every hour, a representative PDF is determined. It is observed that TEC values have a strong hourly, seasonal and positional dependence on east-west direction, and the growing trend shifts according to sunrise and sunset times. It is observed that the data are distributed predominantly as Lognormal and Weibull. The averages and standard deviations of the chosen distributions follow the trends in 24 hour diurnal and 11 year solar cycle periods. The regional and seasonal behavior of PDFs are investigated using a representative GPS station within each region. Within-the-hour PDF estimates are grouped into ionospheric seasons as Winter, Summer, March equinox and September equinox. In winter and summer seasons, Lognormal distribution is observed. During equinox seasons, Weibull distribution is observed more frequently. Furthermore, all hourly TEC values in same region are combined in order to improve the reliability and accuracy of the probability density function estimates. It is observed that as being in mid-latitude region, the ionosphere over Turkey has robust characteristics that are distributed as Lognormal and Weibull. Statistical observations on PDF estimates of TEC of the ionosphere over Turkey will contribute to developing a regional and seasonal random field model, which will further contribute to HF channel characterization. This study is supported by a joint grant of TUBITAK 112E568 and RFBR 13-02-91370-CT_a.
NASA Astrophysics Data System (ADS)
Bao, Hai; Shrestha, Kundan Lal; Kondo, Akira; Kaga, Akikazu; Inoue, Yoshio
2010-01-01
Tropospheric ozone adversely affects human health and vegetation, and biogenic volatile organic compound (BVOC) emission has potential to influence ozone concentration in summer season. In this research, the standard emissions of isoprene and monoterpene from the vegetation of the Kinki region of Japan, estimated from growth chamber experiments, were converted into hourly emissions for July 2002 using the temperature and light intensity data obtained from results of MM5 meteorological model. To investigate the effect of BVOC emissions on ozone production, two ozone simulations for one-month period of July 2002 were carried out. In one simulation, hourly BVOC emissions were included (BIO), while in the other one, BVOC emissions were not considered (NOBIO). The quantitative analyses of the ozone results clearly indicate that the use of spatio-temporally varying BVOC emission improves the prediction of ozone concentration. The hourly differences of monthly-averaged ozone concentrations between BIO and NOBIO had the maximum value of 6 ppb at 1400 JST. The explicit difference appeared in urban area, though the place where the maximum difference occurred changed with time. Overall, BVOC emissions from the forest vegetation strongly affected the ozone generation in the urban area.
NASA Astrophysics Data System (ADS)
Larrañeta, M.; Moreno-Tejera, S.; Lillo-Bravo, I.; Silva-Pérez, M. A.
2018-02-01
Many of the available solar radiation databases only provide global horizontal irradiance (GHI) while there is a growing need of extensive databases of direct normal radiation (DNI) mainly for the development of concentrated solar power and concentrated photovoltaic technologies. In the present work, we propose a methodology for the generation of synthetic DNI hourly data from the hourly average GHI values by dividing the irradiance into a deterministic and stochastic component intending to emulate the dynamics of the solar radiation. The deterministic component is modeled through a simple classical model. The stochastic component is fitted to measured data in order to maintain the consistency of the synthetic data with the state of the sky, generating statistically significant DNI data with a cumulative frequency distribution very similar to the measured data. The adaptation and application of the model to the location of Seville shows significant improvements in terms of frequency distribution over the classical models. The proposed methodology applied to other locations with different climatological characteristics better results than the classical models in terms of frequency distribution reaching a reduction of the 50% in the Finkelstein-Schafer (FS) and Kolmogorov-Smirnov test integral (KSI) statistics.
Convective rain rates and their evolution during storms in a semiarid climate
NASA Technical Reports Server (NTRS)
Doneaud, A. A.; Miller, J. R., Jr.; Ionescu-Niscov, S.
1984-01-01
The semiarid climate of the U.S. northern High Plains region has been studied with respect to rain rates and their evolution during summertime convective storms, using radar data from a total of 750 radar echo clusters. Analysis of this data suggests that the average rain rate R among storms is in a first approximation independent of the total rain volume, if the entire storm duration is considered in the averaging process. R primarily depends on the reflectivity threshold considered in calculating the area coverage integrated over the lifetime of the storm. R evolution during storms is analyzed by dividing each storm lifetime into 10 min, 1, 2, and 4 hours, as well as growing and decaying periods. The value of R remained independent of the total rain volume when the growing or decaying periods of storms were considered separately.
VizieR Online Data Catalog: Horizontal temperature at Venus upper atmosphere (Peralta+, 2016)
NASA Astrophysics Data System (ADS)
Peralta, J.; Lopez-Valverde, M. A.; Gilli, G.; Piccialli, A.
2015-11-01
The dayside atmospheric temperatures in the UMLT of Venus (displayed in Figure 7A of this article) are listed as a CSV data file. These values consist of averages in bins of 5° in latitude and 0.25-hours in local time from dayside temperatures covering five years of data (from 2006/05/14 to 2011/06/05). These temperatures were inferred from the CO2 NLTE nadir spectra measured by the instrument VIRTIS-H onboard Venus Express (see article for full description of the procedure), and are representative of the atmospheric region between 10-2 to 10-5mb. Along with the temperatures, we also provide the corresponding error and the number of temperatures averaged in each bin. The format of the CSV file reasonably agrees with the expected format of the data files to be provided in the future version of the Venus International Reference Atmosphere (VIRA). (1 data file).
The value of normalization: Group therapy for individuals with brain injury.
von Mensenkampff, Barbara; Ward, Marcia; Kelly, Grace; Cadogan, Sam; Fawsit, Feargus; Lowe, Niamh
2015-01-01
This paper reports on a client-driven therapy group designed to help clients actively process changes and equip them with the psychological skills necessary to facilitate rehabilitation. This is an exploratory mixed methods research design based in clinical practice. This study documents results from five therapy groups, each group consisting of 2-hour sessions over an average of 6 weeks with a review session 6 weeks later. Forty-five clients (13 female, 32 male, average age = 40.54, SD = 11.87) with brain injury attended the group with Headway psychological services, Cork. Clients' pre- and post-measures of functioning were gathered to assess the potential therapeutic benefits. Thematic analysis was used to evaluate the qualitative data. Results illustrate a number of benefits to the participants, including normalizing effects, helping with acceptance, finding a new identity and positive mental health changes. Findings are encouraging and help to validate the effectiveness of group therapy as an intervention tool.
[The effect of nimodipine on cochlear blood flow in the guinea pig].
Meyer, P; Werner, E; Schmidt, R; Grützmacher, W; Gehrig, W; Seuter, F
1994-10-01
The influence of nimodipine (Nimotop, CAS 66085-59-4), a selectively cerebrovascularly acting 1,4-dihydropyridine calcium antagonist, on the cochlear blood flow (CBF) was studied in 19 guinea pigs (6 controls). The hydrogen clearance measurements were carried out under alpha-chloralose-ethylurethane anaesthesia, artificial respiration with simultaneous control of electrocardiogram, blood pressure, body temperature and arterial pH (hourly). The indirect measurement of CBF was carried out by means of hydrogen clearance in the perilymphatic space (basal turn) before and after intravenous application of 1 microgram nimodipine/kg/min. The mean arterial blood pressure remained within the +/- 5% range of the initial value during the experiment. Under treatment with nimodipine the CBF showed a non-significant average increase of 4.69% and under placebo (20% ethanol, 17% polyethylenglycol 400, citrate buffer), a non-significant average decrease of 6.16%. The influence of nimodipine on CBF was underlined by the overcompensation of the placebo effect.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1978-01-01
Five cells provided by NASA's Goddard Space Flight Center were evaluated at room temperature and pressure (25 C plus or minus 2 C) with discharges at the 2 hour rate. Measurements of the cell containers following test, indicated an average increase of .006 inches at the plate thickness. Average end of charge voltages and pressures, and capacity output in ampere hours were determined. Three cells exceeded the voltage requirements of 1.52 volts during both c/10 charges at 20 C. All cells exceeded the voltage requirement of 1.52 volts during the 0 C overcharge test, although their end charges were below 1.50 volts. The pressure requirement of 65 psia was exceeded by both pressure transducer cells during c/10 charges at 25 C and 20 C and also during the 0 C overcharge test. The cells with pressure transducers reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test, and exhibited a pressure decay of 2 psia during the last 30 minutes of the 1 hour open circuit stand. Average capacity was 51.3 ampere hours.
Fandel, Christina L.; Lippmann, Thomas C.; Foster, Diane L.; Brothers, Laura L.
2017-01-01
Current observations and sediment characteristics acquired within and along the rim of two pockmarks in Belfast Bay, Maine, were used to characterize periods of sediment transport and to investigate conditions favorable to the settling of suspended sediment. Hourly averaged Shields parameters determined from horizontal current velocity profiles within the center of each pockmark never exceed the critical value (approximated with the theoretical model of Dade et al. 1992). However, Shields parameters estimated at the pockmark rims periodically exceed the critical value, consistent with conditions that support the onset of sediment transport and suspension. Below the rim in the near-center of each pockmark, depth-averaged vertical velocities were less than zero (downward) 60% and 55% of the time in the northern and southern pockmarks, and were often comparable to depth-averaged horizontal velocities. Along the rim, depth-averaged vertical velocities over the lower 8 m of the water column were primarily downward but much less than depth-averaged horizontal velocities indicating that suspended sediment may be moved to distant locations. Maximum grain sizes capable of remaining in suspension under terminal settling flow conditions (ranging 10–170 μm) were typically much greater than the observed median grain diameter (about 7 μm) at the bed. During upwelling flow within the pockmarks, and in the absence of flocculation, suspended sediment would not settle. The greater frequency of predicted periods of sediment transport along the rim of the southern pockmark is consistent with pockmark morphology in Belfast Bay, which transitions from more spherical to more elongated toward the south, suggesting near-bed sediment transport may contribute to post-formation pockmark evolution during typical conditions in Belfast Bay.
The United States Marine Corps in Cyberspace: Every Marine a Cyber Warrior
2008-01-01
information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and...maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other...TillS COLLECTION OF INFORMATION IS ESTIMATED TO AVERAGE I HOUR PER RESPONSE, INCWDING TIlE TIME FOR REVIEWING INSTRUCTIONS. SEARCHING E.’\\’lSTING
Wu, Tina; Bell, Mark R; Blakeman, James R; Edwards, Irv; Mallon, William K
2009-08-01
Physician reimbursement laws for diagnostic interpretive services require that only those services provided contemporaneously and /or contribute directly to patient care can be billed for. Despite these regulations, cardiologists and radiologists in many hospitals continue to bill for ECG and plain film diagnostic services performed in the emergency department (ED). The reimbursement value of this care, which is disconnected in time and place from the ED patient encounter, is unknown. In a California community ED with a 32,000 annual census, the emergency physicians (EPs) alone, by contract, bill for all ECG readings and plain film interpretations when the radiologists are not available to provide contemporaneous readings. To determine the impact of this billing practice on actual EP reimbursement we undertook an analysis that allows calculation of physician reimbursement from billing data. An IRB-approved analysis of 12 months of billing data cleansed of all patient identifiers was undertaken for 2003. From the data we created a descriptive study with itemized breakdown of reimbursement for radiograph and ECG interpretive services (procedures) and the gross resultant physician income. In 2003 EPs at this hospital treated patients during 32,690 ED visits. Total group income in 2003 for radiographs was $173,555 and $91,025 for ECGs, or $19/EP hour and $6/EP hour respectively. For the average full-time EP, the combined total is $2537/month or $30,444 per annum, per EP. This is $8/ED visit (averaged across all patients). As EP-reimbursement is challenged by rising malpractice premiums, uninsured patients, HMO contracts, unfunded government mandates and state budgetary shortfalls, EPs are seeking to preserve their patient services and resultant income. They should also be reimbursed for those services and the liability that they incur. The reimbursement value of ECGs and plain film interpretations to the practicing EP is substantial. In the ED studied, it represents $30,444 gross income per full-time EP annually. Plain film interpretation services produce three times the hourly revenue of ECG reading at the hospital studied.
[Pharmacokinetic and clinical studies of cefmenoxime in neonates and premature infants].
Toyonaga, Y; Sugita, M; Kurosu, Y; Hori, M; Seo, K
1989-12-01
Serum concentrations and urinary recovery rates of cefmenoxime (CMX) were determined in 41 mature and premature infants (with ages 0-24 days) after one shot intravenous injection of 10, 20 (1-hour intravenous drip infusion was also carried out) or 30 mg/kg for treatment and prophylaxis of various infections. Because the number of cases included was small, a comparison study was conducted by classifying them into 3 groups; 3 days or younger, 4 to 7 days, and 8 days or older, rather than dividing them into groups of mature and premature infants. Clinical evaluation was conducted in 7 male and 1 female cases 1 to 29 days old, whose diseases comprised 1 case each with septicemia, purulent otitis media and phlegmonous cellulitis, 3 with pneumonia and 2 with urinary tract infection. 1. Changes in serum concentrations and urinary recovery rates (1) Intravenous bolus injection of 10 mg/kg: Serum concentrations of the drug in the 3 age groups peaked at 28.9, 29.5 and 29.1 micrograms/ml, respectively, all at 30 minutes after the drug administration, and thereafter gradually declined. The mean level in the 3rd group was the lowest at 1.9 micrograms/ml at 6 hours. Average serum half-lives of CMX were shorter in older subjects, 3.0, 1.9 and 1.4 hours, respectively in the 3 groups. Urinary recovery rates were relatively high, 68.9 to 84.9% in the 3 cases examined during the first 6 hours, and 15.4 to 66.2% during the first 2 hours. (2) Intravenous bolus injection of 20 mg/kg: Serum concentrations of the drug in the 3 groups peaked at 65.2, 60.5 and 65.8 micrograms/ml, respectively, all at 30 minutes after the drug administration, with no significant differences noted among the groups. The levels gradually declined thereafter in all groups, but remained rather high at 20.1, 6.5 and 9.5 micrograms/ml, respectively, at 6 hours. Average serum half-lives of CMX were 3.5, 1.7 and 1.9 hours, respectively. The inversion of values obtained between the 2nd and 3rd groups appears to be attributable to that all of the 3rd group were premature infants, and the body weight of 2 cases of them were less than 2,000 g each. Urinary recovery rates ranged widely from 37.0 to 89.4% in the 4 cases examined during the first 6 hours. (3) One-hour intravenous drip infusion of 20 mg/kg: Serum concentrations of the drug in the 3 groups peaked at 57.7, 60.2 and 72.4 micrograms/ml, respectively, all at the termination of the drug infusion.(ABSTRACT TRUNCATED AT 400 WORDS)
48-hours administration of fenoterol in spontaneous preterm labor - does it affect fetal preload?
Grzesiak, Mariusz; Forys, Sebastian; Sobczak, Malgorzata; Ahmed, Rehana B; Wilczynski, Jan
2013-01-01
to investigate whether any changes in the preload index (PLI) occur within the first 48 hours of fenoterol intravenous tocolysis. Doppler evaluation of placental and fetal circulation was performed in 36 pregnant women prior to fenoterol administration and after 24/48 hours. Measurements were obtained from a longitudinal section of the inferior vena cava (IVC) and preload index was calculated. To determine changes over time, an all study variable analysis of variance (ANOVA) for repeated measurements, followed by Tukey-Kramer's multiple comparison test was used. The effects of additional clinical covariates were checked. The maternal heart rate values were significantly increased after 24 hours and 48 hours in comparison to pre-treatment values. No significant changes in fetal heart rate were observed during treatment. The fetal IVC PLI values were significantly reduced after 24 hours and 48 hours of treatment. The increase in PLI values when comparing 24 and 48 hours results were not statistically significant. These observations were consistent with ANOVA post-hoc analysis. 48 hours intravenous administration of fenoterol appears not to alter inferior vena cava blood flow by itself. The reduction in PLI values may reflect lower fetal preload conditions during the course of successful tocolytic treatment. Therefore, Doppler IVC PLI measurement should be considered as a possible additional assessment method of effectiveness of treatment. However, other Doppler venous blood flow parameters should be assessed to confirm the results and clarify whether maternal corticosteroids administration may be interfering with the results.
High historical values of foEs—Reality or artefact?
NASA Astrophysics Data System (ADS)
Laštovička, J.; Boška, J.; Burešová, D.; Kouba, D.
2012-01-01
Very high values of foEs had sometimes been reported in the past. These values, as well as all other ionogram-scaled values, had been derived from ionograms under the assumption of the vertical reflection of ordinary mode of sounding radio waves. In the past it was impossible to check the validity of this assumption. However, modern digisondes determine clearly the oblique or extraordinary mode reflections. To test the assumption of the vertical reflection of ordinary mode for high values of foEs, seven summers (June 2004-August 2010) from a midlatitude station Pruhonice are chosen. All hourly values of foEs≥6.0 MHz are selected from this data set, altogether 282 values. In 90% of cases the “classical” way of evaluation of foEs provides values higher than “true” values from modern digisonde (average difference about 1 MHz). 38% of “classical” foEs are oblique reflections, which however do not occur in direction perpendicular to geomagnetic field. The occurrence of high values of foEs varies very much from year to year between 0 and 130 events per year. As for diurnal variation, a pronounced maximum occurs at ˜10:00LT and 16:00LT (secondary), and a minimum after midnight.
Global Positioning System (GPS) Precipitable Water in Forecasting Lightning at Spaceport Canaveral
NASA Technical Reports Server (NTRS)
Kehrer, Kristen; Graf, Brian G.; Roeder, William
2005-01-01
Using meteorology data, focusing on precipitable water (PW), obtained during the 2000-2003 thunderstorm seasons in Central Florida, this paper will, one, assess the skill and accuracy measurements of the current Mazany forecasting tool and, two, provide additional forecasting tools that can be used in predicting lightning. Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) are located in east Central Florida. KSC and CCAFS process and launch manned (NASA Space Shuttle) and unmanned (NASA and Air Force Expendable Launch Vehicles) space vehicles. One of the biggest cost impacts is unplanned launch scrubs due to inclement weather conditions such as thunderstorms. Each launch delay/scrub costs over a quarter million dollars, and the need to land the Shuttle at another landing site and return to KSC costs approximately $ 1M. Given the amount of time lost and costs incurred, the ability to accurately forecast (predict) when lightning will occur can result in significant cost and time savings. All lightning prediction models were developed using binary logistic regression. Lightning is the dependent variable and is binary. The independent variables are the Precipitable Water (PW) value for a given time of the day, the change in PW up to 12 hours, the electric field mill value, and the K-index value. In comparing the Mazany model results for the 1999 period B against actual observations for the 2000-2003 thunderstorm seasons, differences were found in the False Alarm Rate (FAR), Probability of Detection (POD) and Hit Rate (H). On average, the False Alarm Rate (FAR) increased by 58%, the Probability of Detection (POD) decreased by 31% and the Hit Rate decreased by 20%. In comparing the performance of the 6 hour forecast period to the performance of the 1.5 hour forecast period for the Mazany model, the FAR was lower by 15% and the Hit Rate was higher by 7%. However, the POD for the 6 hour forecast period was lower by 16% as compared to the POD of the 1.5 hour forecast period. Neither forecast period performed at the accuracy measures expected. A 2-Hr Forecasting Tool was developed to support a Phase I Lightning Advisory, which requires a 30-minute lead time for predicting lightning.
Association of Physical Activity by Type and Intensity With Digestive System Cancer Risk.
Keum, NaNa; Bao, Ying; Smith-Warner, Stephanie A; Orav, John; Wu, Kana; Fuchs, Charles S; Giovannucci, Edward L
2016-09-01
Accumulating evidence indicates that common carcinogenic pathways may underlie digestive system cancers. Physical activity may influence these pathways. Yet, to our knowledge, no previous study has evaluated the role of physical activity in overall digestive system cancer risk. To examine the association between physical activity and digestive system cancer risk, accounting for amount, type (aerobic vs resistance), and intensity of physical activity. A prospective cohort study followed 43 479 men from the Health Professionals Follow-up Study from 1986 to 2012. At enrollment, the eligible participants were 40 years or older, were free of cancer, and reported physical activity. Follow-up rates exceeded 90% in each 2-year cycle. The amount of total physical activity expressed in metabolic equivalent of task (MET)-hours/week. Incident cancer of the digestive system encompassing the digestive tract (mouth, throat, esophagus, stomach, small intestine, and colorectum) and digestive accessory organs (pancreas, gallbladder, and liver). Over 686 924 person-years, we documented 1370 incident digestive system cancers. Higher levels of physical activity were associated with lower digestive system cancer risk (hazard ratio [HR], 0.74 for ≥63.0 vs ≤8.9 MET-hours/week; 95% CI, 0.59-0.93; P value for trend = .003). The inverse association was more evident with digestive tract cancers (HR, 0.66 for ≥63.0 vs ≤8.9 MET-hours/week; 95% CI, 0.51-0.87) than with digestive accessary organ cancers. Aerobic exercise was particularly beneficial against digestive system cancers, with the optimal benefit observed at approximately 30 MET-hours/week (HR, 0.68; 95% CI, 0.56-0.83; P value for nonlinearity = .02). Moreover, as long as the same level of MET-hour score was achieved from aerobic exercise, the magnitude of risk reduction was similar regardless of intensity of aerobic exercise. Physical activity, as indicated by MET-hours/week, was inversely associated with the risk of digestive system cancers, particularly digestive tract cancers, in men. The optimal benefit was observed through aerobic exercise of any intensity at the equivalent of energy expenditure of approximately 10 hours/week of walking at average pace. Future studies are warranted to confirm our findings and to translate them into clinical and public health recommendation.
Lee, Mi Jung; Park, Jung Tak; Park, Kyoung Sook; Kwon, Young Eun; Oh, Hyung Jung; Yoo, Tae-Hyun; Kim, Yong-Lim; Kim, Yon Su; Yang, Chul Woo; Kim, Nam-Ho; Kang, Shin-Wook; Han, Seung Hyeok
2017-03-07
Residual kidney function can be assessed by simply measuring urine volume, calculating GFR using 24-hour urine collection, or estimating GFR using the proposed equation (eGFR). We aimed to investigate the relative prognostic value of these residual kidney function parameters in patients on dialysis. Using the database from a nationwide prospective cohort study, we compared differential implications of the residual kidney function indices in 1946 patients on dialysis at 36 dialysis centers in Korea between August 1, 2008 and December 31, 2014. Residual GFR calculated using 24-hour urine collection was determined by an average of renal urea and creatinine clearance on the basis of 24-hour urine collection. eGFR-urea, creatinine and eGFR β 2 -microglobulin were calculated from the equations using serum urea and creatinine and β 2 -microglobulin, respectively. The primary outcome was all-cause death. During a mean follow-up of 42 months, 385 (19.8%) patients died. In multivariable Cox analyses, residual urine volume (hazard ratio, 0.96 per 0.1-L/d higher volume; 95% confidence interval, 0.94 to 0.98) and GFR calculated using 24-hour urine collection (hazard ratio, 0.98; 95% confidence interval, 0.95 to 0.99) were independently associated with all-cause mortality. In 1640 patients who had eGFR β 2 -microglobulin data, eGFR β 2 -microglobulin (hazard ratio, 0.98; 95% confidence interval, 0.96 to 0.99) was also significantly associated with all-cause mortality as well as residual urine volume (hazard ratio, 0.96 per 0.1-L/d higher volume; 95% confidence interval, 0.94 to 0.98) and GFR calculated using 24-hour urine collection (hazard ratio, 0.97; 95% confidence interval, 0.95 to 0.99). When each residual kidney function index was added to the base model, only urine volume improved the predictability for all-cause mortality (net reclassification index =0.11, P =0.01; integrated discrimination improvement =0.01, P =0.01). Higher residual urine volume was significantly associated with a lower risk of death and exhibited a stronger association with mortality than GFR calculated using 24-hour urine collection and eGFR-urea, creatinine. These results suggest that determining residual urine volume may be beneficial to predict patient survival in patients on dialysis. Copyright © 2017 by the American Society of Nephrology.
Farm work exposure of older male farmers in Saskatchewan.
Voaklander, Donald C; Dosman, James A; Hagel, Louise M; Warsh, Joel; Pickett, William
2010-07-01
The average age of farmers in North America is increasing each year. Research has determined that age and health status are both related to increased risk of injury. The purpose of this research was to determine the association of health and medication factors with exposure to farm work in older male farmers. As part of a cohort study to study determinants of injury on Saskatchewan farms, 5,502 farm people associated with 2,386 Saskatchewan farms were surveyed by mail questionnaire during the winter of 2007. The primary dependent variable was average hours per week of farm work. Independent variables included illnesses, age, and medication use. The mean number of hours worked per week by farmers aged 55 years and older was 48. There was a significant relationship between age and hours worked with each year of age accounting for about 0.85 hr less work per week. Medication use was related to a reduction in weekly work hours during the busy fall season but was not related to work exposure averaged over the whole year. In multivariable linear regression analysis, the main contributing variables to farm work exposure were: retired status (-), working off farm (-), and age (-). The amount of hours older farmers work on the farm is considerable compared to any other occupational category. While there is a declining trend in the amount of work, a 75-year-old farmer still works, on average, about 34 hr per week. Some farmers do appear to self-limit during busy times of the year if they are taking medication. 2010 Wiley-Liss, Inc.
The deployment of carbon monoxide wireless sensor network (CO-WSN) for ambient air monitoring.
Chaiwatpongsakorn, Chaichana; Lu, Mingming; Keener, Tim C; Khang, Soon-Jai
2014-06-16
Wireless sensor networks are becoming increasingly important as an alternative solution for environment monitoring because they can reduce cost and complexity. Also, they can improve reliability and data availability in places where traditional monitoring methods are difficult to site. In this study, a carbon monoxide wireless sensor network (CO-WSN) was developed to measure carbon monoxide concentrations at a major traffic intersection near the University of Cincinnati main campus. The system has been deployed over two weeks during Fall 2010, and Summer 2011-2012, traffic data was also recorded by using a manual traffic counter and a video camcorder to characterize vehicles at the intersection 24 h, particularly, during the morning and evening peak hour periods. According to the field test results, the 1 hr-average CO concentrations were found to range from 0.1-1.0 ppm which is lower than the National Ambient Air Quality Standards (NAAQS) 35 ppm on a one-hour averaging period. During rush hour periods, the traffic volume at the intersection varied from 2,067 to 3,076 vehicles per hour with 97% being passenger vehicles. Furthermore, the traffic volume based on a 1-h average showed good correlation (R2 = 0.87) with the 1-h average CO-WSN concentrations for morning and evening peak time periods whereas CO-WSN results provided a moderate correlation (R2 = 0.42) with 24 hours traffic volume due to fluctuated changes of meteorological conditions. It is concluded that the performance and the reliability of wireless ambient air monitoring networks can be used as an alternative method for real time air monitoring.
Scientific Inquiry into Home Electronic Technology Usage
ERIC Educational Resources Information Center
Lazaros, Edward J.; Spotts, Thomas H.; Verdon, Jessica E.
2010-01-01
This activity promotes ways to save electricity in the home. Students identify electronic devices in the home and examine wattage, hours of use per month, estimated wattage per month, kilowatt hours per month, average retail price per kilowatt hour in each state, and the estimated cost per month. Students gain an appreciation for how saving power…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... submitted to the Office of Management and Budget (OMB) for review and approval. Proposed Collection: The... Investigators, 1; Trainees, 1; Average burden hours per response: 30 minutes; and Estimated total annual burden hours requested: 250 hours. The total annualized cost to respondents (calculated as the number of...
5 CFR 630.1203 - Leave entitlement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... scheduled administrative workweek. If the number of hours in an employee's workweek varies from week to week, a weekly average of the hours scheduled over the 12 weeks prior to the date leave commences shall be... the 12-week entitlement to family and medical leave. (f) If the number of hours in an employee's...
Effectiveness of Strategy Instruction Using Podcasts in Second Language Listening and Speaking
ERIC Educational Resources Information Center
Kang, Tingting
2016-01-01
Mobile devices have become a significant part of students' lives. The average number of hours that college students reported using their smartphones each day was nine hours--more than half of their daily waking hours (Roberts, Yaya, & Manolis, 2014). Although software developers and teachers have started to develop and incorporate various…
Academic Efforts and Study Habits among Students in a Principles of Macroeconomics Course.
ERIC Educational Resources Information Center
Okpala, Amon O.; Okpala, Comfort O.; Ellis, Richard
2000-01-01
Students in a macroeconomics course (n=132) were compared on grade point average, academic efficacy, credit hours accumulated, and study hours/habits. Academic efficacy and study habits significantly explained achievement. The amount of study time had no significant impact. Scholastic Assessment Test scores and credit hours explained achievement…
In this article we describe an approach for predicting average hourly concentrations of ambient PM10 in Vancouver. We know our solution also applies to hourly ozone fields and believe it may be quite generally applicable. We use a hierarchal Bayesian approach. At the primary ...
Solar energy potential in the United Arab Emirates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalil, A.; Alnajjar, A.
1995-12-31
In the present study, the global, direct and diffuse components of solar radiation as well as temperature, relative humidity and wind speed have been continuously monitored and analyzed on hourly, daily and monthly basis. Experimental data is compared to the predictions of different theoretical models as functions of declination and hour angles. Correlations are obtained describing the variation of hourly, daily and monthly averages of total and diffuse solar radiation using polynomial expressions. Empirical correlations describing the dependence of the daily average diffuse to total radiation ratio on the clearness index are also obtained. Data of daily diffuse to totalmore » radiation ratio is compared to correlations obtained by other investigators. The comparison shows a reasonable agreement with some scatter due to the seasonal dependence of the correlation. Comparison of calculations with experimental measurements under clear sky conditions show excellent agreement with a maximum error of 8%. The measured ratio of hourly to daily insolation is in excellent agreement with the model of Hottel which is expressed as a function of the clearness index, hour and the sunset hour angles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolokotroni, Maria; Bhuiyan, Saiful; Davies, Michael
2010-12-15
This paper describes a method for predicting air temperatures within the Urban Heat Island at discreet locations based on input data from one meteorological station for the time the prediction is required and historic measured air temperatures within the city. It uses London as a case-study to describe the method and its applications. The prediction model is based on Artificial Neural Network (ANN) modelling and it is termed the London Site Specific Air Temperature (LSSAT) predictor. The temporal and spatial validity of the model was tested using data measured 8 years later from the original dataset; it was found thatmore » site specific hourly air temperature prediction provides acceptable accuracy and improves considerably for average monthly values. It thus is a very reliable tool for use as part of the process of predicting heating and cooling loads for urban buildings. This is illustrated by the computation of Heating Degree Days (HDD) and Cooling Degree Hours (CDH) for a West-East Transect within London. The described method could be used for any city for which historic hourly air temperatures are available for a number of locations; for example air pollution measuring sites, common in many cities, typically measure air temperature on an hourly basis. (author)« less
Total fume and metal concentrations during welding in selected factories in Jeddah, Saudi Arabia.
Balkhyour, Mansour Ahmed; Goknil, Mohammad Khalid
2010-07-01
Welding is a major industrial process used for joining metals. Occupational exposure to welding fumes is a serious occupational health problem all over the world. The degree of risk to welder's health from fumes depends on composition, concentration, and the length of exposure. The aim of this study was to investigate workers' welding fume exposure levels in some industries in Jeddah, Saudi Arabia. In each factory, the air in the breathing zone within 0.5 m from welders was sampled during 8-hour shifts. Total particulates, manganese, copper, and molybdenum concentrations of welding fumes were determined. Mean values of eight-hour average particulate concentrations measured during welding at the welders breathing zone were 6.3 mg/m(3) (Factory 1), 5.3 mg/m(3) (Factory 2), 11.3 mg/m(3) (Factory 3), 6.8 mg/m(3) (Factory 4), 4.7 mg/m(3) (Factory 5), and 3.0 mg/m(3) (Factory 6). Mean values of airborne manganese, copper, and molybdenum levels measured during welding were in the range of 0.010 mg/m(3)-0.477 mg/m(3), 0.001 mg/m(3)-0.080 mg/m(3) and 0.001 mg/m(3)-0.058 mg/m(3) respectively. Mean values of calculated equivalent exposure values were: 1.50 (Factory 1), 1.56 (Factory 2), 5.14 (Factory 3), 2.21 (Factory 4), 2.89 (Factory 5), and 1.20 (Factory 6). The welders in factories 1, 2, 3, and 4 were exposed to welding fume concentration above the SASO limit value, which may increase the risk of respiratory health problems.
Code of Federal Regulations, 2012 CFR
2012-01-01
... biweekly pay period), excluding sleep and standby duty hours, provided the regular tour of duty does not... effect throughout the year, averages at least 106 hours per biweekly pay period; and (2) Who is in a...
Code of Federal Regulations, 2013 CFR
2013-01-01
... biweekly pay period), excluding sleep and standby duty hours, provided the regular tour of duty does not... effect throughout the year, averages at least 106 hours per biweekly pay period; and (2) Who is in a...
Code of Federal Regulations, 2014 CFR
2014-01-01
... biweekly pay period), excluding sleep and standby duty hours, provided the regular tour of duty does not... effect throughout the year, averages at least 106 hours per biweekly pay period; and (2) Who is in a...
77 FR 22615 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-16
.... The Commission estimates that approximately 209 broker-dealers will spend an average of 87 hours annually to comply with this rule. Thus, the total compliance burden is approximately 18,200 burden-hours...
77 FR 29394 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
.... The Commission estimates that approximately 209 broker-dealers will spend an average of 87 hours annually to comply with the rule. Thus, the total compliance burden is approximately 18,183 burden-hours...
NASA Astrophysics Data System (ADS)
DeWinter, Jennifer L.; Brown, Steven G.; Seagram, Annie F.; Landsberg, Karin; Eisinger, Douglas S.
2018-06-01
In 2010, the U.S. Environmental Protection Agency (EPA) revised the National Ambient Air Quality Standards (NAAQS) for NO2 to include a primary health-based standard for hourly NO2, and required air quality monitoring next to major roadways in urban areas in the U.S. Requirements for near-road measurements also include carbon monoxide (CO) and particulate matter smaller than 2.5 μm in diameter (PM2.5). We performed a national-scale assessment of air pollutants measured at 81 sites in the near-road environment during the first two years (2014 and 2015) of the new measurement program. We evaluated how concentrations at these locations compared to the NAAQS, to concentrations measured at other sites within the same urban areas, and when considering their site characteristics (distance of monitor to road, traffic volume, and meteorology). We also estimated the contribution of emissions from adjacent roadways at each near-road site to the PM2.5 concentrations above the local urban background concentrations, i.e., the near-road "increment." Hourly values of CO reached a maximum of 4.8 ppm across 31 sites in 2014 and 9.6 ppm across 47 sites in 2015, and were well below the NAAQS levels for both the 1-hr (35 ppm) and 8-hr (9 ppm) standards. Hourly concentrations of near-road NO2 reached 258 ppb across 40 sites in 2014; however, there were only two occurrences of a daily 1-hr maximum NO2 concentration above 100 ppb (the level of the hourly NO2 standard). In 2015, hourly concentrations of near-road NO2, monitored at 61 sites in 55 urban areas, reached 154 ppb. Only 0.0015% (n = 5) of hourly NO2 observations in 2015 exceeded 100 ppb. The highest annual NO2 average recorded in 2015 (29.9 ppb) occurred at the Ontario site located along I-10 in the Los Angeles, California, area and was below the level of the NO2 annual standard (53 ppb); in 2014, the highest annual mean NO2 was also observed in Los Angeles at the Anaheim site (27.1 ppb). In 2014, sites in Cincinnati, Indianapolis, and Louisville recorded annual average PM2.5 concentrations at or above 12 μg/m3 (the level of the annual standard). There were 15 occurrences in 2014 of 24-hr PM2.5 concentrations above the NAAQS level of 35 μg/m3. Annual average PM2.5 exceeded 12 μg/m3 at near-road sites in five urban areas in 2015, and there were 33 days across 12 near-road locations with 24-hr PM2.5 concentrations above 35 μg/m3. Across the near-road monitoring network, annual average PM2.5 concentrations did not have a significant relationship with traffic volume or distance between the monitor and the adjacent roadway; rather, variations in PM2.5 were mostly driven by urban-scale PM2.5, with a typically small "increment" above urban-scale concentrations due to a site's proximity to the roadway. We estimated this increment, i.e., the difference between near-road PM2.5 concentrations and the concentrations at sites in the urban area of each near-road monitor, to be on average 1.2 μg/m3 (σ = 0.3 μg/m3), with a range of -1.2 μg/m3 to 3.1 μg/m3 across the 26 sites (four of which had a negative increment). The near-road increment is on average 13% of the near-road PM2.5, and 15% of the near-road PM2.5 for sites within 20 m of the roadway.