To evaluate the validity of Recurring Esthetic Dental proportion in natural dentition
Shetty, Shilpa; Pitti, Varun; Satish Babu, CL; Surendra Kumar, GP; Jnanadev, KR
2011-01-01
Background: Different proportions are described in the literature for smile designing, such as Golden proportion, Golden percentage, Preston's proportion, and recently, Recurring Esthetic Dental (RED) proportion. Aims and Objectives: To evaluate the existence of RED proportion in natural dentition. To determine the relative height of maxillary lateral incisor and canine occurring in natural dentition so that it can be used in any of the above proportions. Materials and Methods: Fifteen male subjects and 15 female subjects in each of the different age groups of 18–23 years, 24–29 years and 30–35 years were selected for this study (total 90). Photographs of the subjects were taken using Nikon D200 camera with 135 mm lens and analyzed using Adobe Photoshop CS4 extended software. The height and width of maxillary central incisors, lateral incisors and canines were found out using the measuring tool provided in the software. Results: Average width ratio and height ratio of maxillary lateral incisor to central incisor and maxillary canine to lateral incisor were calculated to check the existence of RED proportion in natural dentition. Average lateral incisor to central incisor height ratio for “small”- and “medium”-sized teeth was found to be 88% and for “tall”-sized teeth was found to be 84%. Average canine to lateral incisor height ratio for “small”- and “medium”-sized teeth was found to be 106% and for “tall”-sized teeth was found to be 105%. Conclusions: Within the limitations of the study, RED proportion was not seen in natural dentition. PMID:22025841
NASA Astrophysics Data System (ADS)
Taheriniya, Shabnam; Parhizgar, Sara Sadat; Sari, Amir Hossein
2018-06-01
To study the alumina template pore size distribution as a function of Al thin film grain size distribution, porous alumina templates were prepared by anodizing sputtered aluminum thin films. To control the grain size the aluminum samples were sputtered with the rate of 0.5, 1 and 2 Å/s and the substrate temperature was either 25, 75 or 125 °C. All samples were anodized for 120 s in 1 M sulfuric acid solution kept at 1 °C while a 15 V potential was being applied. The standard deviation value for samples deposited at room temperature but with different rates is roughly 2 nm in both thin film and porous template form but it rises to approximately 4 nm with substrate temperature. Samples with the average grain size of 13, 14, 18.5 and 21 nm respectively produce alumina templates with an average pore size of 8.5, 10, 15 and 16 nm in that order which shows the average grain size limits the average pore diameter in the resulting template. Lateral correlation length and grain boundary effect are other factors that affect the pore formation process and pore size distribution by limiting the initial current density.
Ndagano, Bienvenu; Mphuthi, Nokwazi; Milione, Giovanni; Forbes, Andrew
2017-10-15
There is interest in using orbital angular momentum (OAM) modes to increase the data speed of free-space optical communication. A prevalent challenge is the mitigation of mode-crosstalk and mode-dependent loss that is caused by the modes' lateral displacement at the data receiver. Here, the mode-crosstalk and mode-dependent loss of laterally displaced OAM modes (LG 0,+1 , LG 0,-1 ) are experimentally compared to that of a Hermite-Gaussian (HG) mode subset (HG 0,1 , HG 1,0 ). It is shown, for an aperture larger than the modes' waist sizes, some of the HG modes can experience less mode-crosstalk and mode-dependent loss when laterally displaced along a symmetry axis. It is also shown, over a normal distribution of lateral displacements whose standard deviation is 2× the modes' waist sizes, on average, the HG modes experience 66% less mode-crosstalk and 17% less mode-dependent loss.
Minor loop dependence of the magnetic forces and stiffness in a PM-HTS levitation system
NASA Astrophysics Data System (ADS)
Yang, Yong; Li, Chengshan
2017-12-01
Based upon the method of current vector potential and the critical state model of Bean, the vertical and lateral forces with different sizes of minor loop are simulated in two typical cooling conditions when a rectangular permanent magnet (PM) above a cylindrical high temperature superconductor (HTS) moves vertically and horizontally. The different values of average magnetic stiffness are calculated by various sizes of minor loop changing from 0.1 to 2 mm. The magnetic stiffness with zero traverse is obtained by using the method of linear extrapolation. The simulation results show that the extreme values of forces decrease with increasing size of minor loop. The magnetic hysteresis of the force curves also becomes small as the size of minor loop increases. This means that the vertical and lateral forces are significantly influenced by the size of minor loop because the forces intensely depend on the moving history of the PM. The vertical stiffness at every vertical position when the PM vertically descends to 1 mm is larger than that as the PM vertically ascents to 30 mm. When the PM moves laterally, the lateral stiffness during the PM passing through any horizontal position in the first time almost equal to the value during the PM passing through the same position in the second time in zero-field cooling (ZFC), however, the lateral stiffness in field cooling (FC) and the cross stiffness in ZFC and FC are significantly affected by the moving history of the PM.
How much does size really matter? Exploring the limits of graphene as Li ion battery anode material
NASA Astrophysics Data System (ADS)
Sun, H.; Varzi, A.; Pellegrini, V.; Dinh, D. A.; Raccichini, R.; Del Rio-Castillo, A. E.; Prato, M.; Colombo, M.; Cingolani, R.; Scrosati, B.; Passerini, S.; Bonaccorso, F.
2017-02-01
We unravel the role of flake dimensionality on the lithiation/de-lithiation processes and electrochemical performance of anodes based on few-(FLG) and multi-layer graphene (MLG) flakes prepared by liquid phase exfoliation (LPE) of pristine graphite. The flakes are sorted by lateral size (from 380 to 75 nm) and thickness from 20 (MLG) to 2 nm (FLG) exploiting a sedimentation-based separation in centrifugal field and, finally, deposited onto Cu disks for the realization of four binder-free anodes. The electrochemical results show that decreasing lateral size and thickness leads to an increase of the initial specific capacity from ≈590 to ≈1270mAhg-1. However, an increasing irreversible capacity is also associated to the reduction of flakes' size. We find, in addition, that the preferential Li ions storage by adsorption rather than intercalation in small lateral size (<100 nm) FLG flakes has a detrimental effect on the average de-lithiation voltage, resulting on low voltage efficiency of these anodes. We believe that the results reported in this work, provide the guidelines for the practical exploitation of graphene-based electrodes.
Johnson, L; van Jaarsveld, C H M; Llewellyn, C H; Cole, T J; Wardle, J
2014-01-01
Objective: Infant growth trajectories, in terms of size, tempo and velocity, may programme lifelong obesity risk. Timing of breastfeeding cessation and weaning are both implicated in rapid infant growth; we examined the association of both simultaneously with a range of growth parameters. Design: Longitudinal population-based twin birth cohort. Subjects: The Gemini cohort provided data on 4680 UK infants with a median of 10 (interquartile range=8–15) weight measurements between birth and a median of 6.5 months. Age at breastfeeding cessation and weaning were reported by parents at mean age 8.2 months (s.d.=2.2, range=4–20). Growth trajectories were modelled using SuperImposition by Translation And Rotation (SITAR) to generate three descriptors of individual growth relative to the average trajectory: size (grams), tempo (weeks, indicating the timing of the peak growth rate) and velocity (% difference from average, reflecting mean growth rate). Complex-samples general linear models adjusting for family clustering and confounders examined associations between infant feeding and SITAR parameters. Results: Longer breastfeeding (>4 months vs never) was independently associated with lower growth velocity by 6.8% (s.e.=1.3%) and delayed growth tempo by 1.0 (s.e.=0.2 weeks), but not with smaller size. Later weaning (⩾6 months vs <4 months) was independently associated with lower growth velocity by 4.9% (s.e.=1.1%) and smaller size by 102 g (s.e.=25 g). Conclusions: Infants breastfed for longer grew slower for longer after birth (later peak growth rate) but were no different in size, while infants weaned later grew slower overall and were smaller but the timing of peak growth did not differ. Slower trajectories with a delayed peak in growth may have beneficial implications for programming later obesity risk. Replication in cohorts with longer follow-up, alternative confounding structures or randomised controlled trials are required to confirm the long-term effects and directionality, and to rule out residual confounding. PMID:24722545
Mermershtain, Wilmosh; Cohen, Yoram; Krutman, Yanai
2003-06-01
The aim of this study was to assess portal imaging for quality assurance of patient positioning in external beam radiotherapy. We present a retrospective study of the variability of patient position in the treatment of 34 prostate cancer patients who were treated with whole pelvic irradiation followed by arc therapy or boost field (Series I) and 25 patients treated by 'small' pelvic 4-field box technique (Series II). Weekly anteroposterior-posteranterior (AP-PA) and left-lateral portal images were compared to simulation films by using a fiducial point-pair registration technique based on the computer-assisted portal imaging quality assurance program PIPSpro, developed specifically for the verification of treatment positioning in radiation therapy. Series I consisted of 34 patients and 194 portal films (97 AP-PA and 97 left-lateral). Overirradiated (OA) and underirradiated (UA) areas were computed in terms of percentage of the reference field size. For the AP-PA portals, the average OA was 2.75% and average UA was 2.74%. For left-lateral portals, an average OA of 2.49% and UA of 2.78% were measured. Series II consisted of 25 patients and 194 portal films (98 AP-PA and 96 left-lateral). The average OA was 0.88% and average UA was 0.86% in AP-PA portals, and 1.03 and 0.82% for left-lateral portals, respectively. The accuracy of patient positioning in irradiation of prostate cancer in our institution is in the range of 2.69% for whole pelvic fields and 1.0% for small fields. We conclude that PIPSpro is an effective and useful tool for quality assurance in radiotherapy.
Long-term patterns of body mass and stature evolution within the hominin lineage.
Will, Manuel; Pablos, Adrián; Stock, Jay T
2017-11-01
Body size is a central determinant of a species' biology and adaptive strategy, but the number of reliable estimates of hominin body mass and stature have been insufficient to determine long-term patterns and subtle interactions in these size components within our lineage. Here, we analyse 254 body mass and 204 stature estimates from a total of 311 hominin specimens dating from 4.4 Ma to the Holocene using multi-level chronological and taxonomic analytical categories. The results demonstrate complex temporal patterns of body size variation with phases of relative stasis intermitted by periods of rapid increases. The observed trajectories could result from punctuated increases at speciation events, but also differential proliferation of large-bodied taxa or the extinction of small-bodied populations. Combined taxonomic and temporal analyses show that in relation to australopithecines, early Homo is characterized by significantly larger average body mass and stature but retains considerable diversity, including small body sizes. Within later Homo , stature and body mass evolution follow different trajectories: average modern stature is maintained from ca 1.6 Ma, while consistently higher body masses are not established until the Middle Pleistocene at ca 0.5-0.4 Ma, likely caused by directional selection related to colonizing higher latitudes. Selection against small-bodied individuals (less than 40 kg; less than 140 cm) after 1.4 Ma is associated with a decrease in relative size variability in later Homo species compared with earlier Homo and australopithecines. The isolated small-bodied individuals of Homo naledi ( ca 0.3 Ma) and Homo floresiensis ( ca 100-60 ka) constitute important exceptions to these general patterns, adding further layers of complexity to the evolution of body size within the genus Homo . At the end of the Late Pleistocene and Holocene, body size in Homo sapiens declines on average, but also extends to lower limits not seen in comparable frequency since early Homo .
Long-term patterns of body mass and stature evolution within the hominin lineage
Pablos, Adrián; Stock, Jay T.
2017-01-01
Body size is a central determinant of a species' biology and adaptive strategy, but the number of reliable estimates of hominin body mass and stature have been insufficient to determine long-term patterns and subtle interactions in these size components within our lineage. Here, we analyse 254 body mass and 204 stature estimates from a total of 311 hominin specimens dating from 4.4 Ma to the Holocene using multi-level chronological and taxonomic analytical categories. The results demonstrate complex temporal patterns of body size variation with phases of relative stasis intermitted by periods of rapid increases. The observed trajectories could result from punctuated increases at speciation events, but also differential proliferation of large-bodied taxa or the extinction of small-bodied populations. Combined taxonomic and temporal analyses show that in relation to australopithecines, early Homo is characterized by significantly larger average body mass and stature but retains considerable diversity, including small body sizes. Within later Homo, stature and body mass evolution follow different trajectories: average modern stature is maintained from ca 1.6 Ma, while consistently higher body masses are not established until the Middle Pleistocene at ca 0.5–0.4 Ma, likely caused by directional selection related to colonizing higher latitudes. Selection against small-bodied individuals (less than 40 kg; less than 140 cm) after 1.4 Ma is associated with a decrease in relative size variability in later Homo species compared with earlier Homo and australopithecines. The isolated small-bodied individuals of Homo naledi (ca 0.3 Ma) and Homo floresiensis (ca 100–60 ka) constitute important exceptions to these general patterns, adding further layers of complexity to the evolution of body size within the genus Homo. At the end of the Late Pleistocene and Holocene, body size in Homo sapiens declines on average, but also extends to lower limits not seen in comparable frequency since early Homo. PMID:29291118
An in vitro comparison of tracheostomy tube cuffs
Maguire, Seamus; Haury, Frances; Jew, Korinne
2015-01-01
Introduction The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT]) with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force. Methods Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O), instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site. Results The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05). The taper-shaped cuff also demonstrated a more even, lower pressure distribution along the lateral wall of the model trachea. The average air and fluid seal performance with the taper-shaped cuff was significantly improved, when compared to the cylindrical-shaped cuff, for each tube size tested (P<0.05). The insertion force for the taper-shaped cuff was ~40% less than that for the cylindrical-shaped cuff. Conclusion In a model trachea, the Shiley™ Flexible Adult tracheostomy tube with TaperGuard™ cuff, when compared to the Shiley™ Disposable Inner Cannula Tracheostomy tube with cylindrical cuff, exerted a lower average lateral wall pressure and a more evenly distributed pressure. In addition, it provided more effective fluid and air seals and required less force to insert. PMID:25960679
Photoacoustic and ultrasound imaging of cancellous bone tissue.
Yang, Lifeng; Lashkari, Bahman; Tan, Joel W Y; Mandelis, Andreas
2015-07-01
We used ultrasound (US) and photoacoustic (PA) imaging modalities to characterize cattle trabecular bones. The PA signals were generated with an 805-nm continuous wave laser used for optimally deep optical penetration depth. The detector for both modalities was a 2.25-MHz US transducer with a lateral resolution of ~1 mm at its focal point. Using a lateral pixel size much larger than the size of the trabeculae, raster scanning generated PA images related to the averaged values of the optical and thermoelastic properties, as well as density measurements in the focal volume. US backscatter yielded images related to mechanical properties and density in the focal volume. The depth of interest was selected by time-gating the signals for both modalities. The raster scanned PA and US images were compared with microcomputed tomography (μCT) images averaged over the same volume to generate similar spatial resolution as US and PA. The comparison revealed correlations between PA and US modalities with the mineral volume fraction of the bone tissue. Various features and properties of these modalities such as detectable depth, resolution, and sensitivity are discussed.
NASA Technical Reports Server (NTRS)
Parfitt, E. A.; Head, J. W., III
1993-01-01
Models of the emplacement of lateral dikes from magma chambers under constant (buffered) driving pressure conditions and declining (unbuffered) driving pressure conditions indicate that the two pressure scenarios lead to distinctly different styles of dike emplacement. In the unbuffered case, the lengths and widths of laterally emplaced dikes will be severely limited and the dike lengths will be highly dependent on chamber size; this dependence suggests that average dike length can be used to infer the dimensions of the source magma reservoir. On Earth, the characteristics of many mafic-dike swarms suggest that they were emplaced in buffered conditions (e.g., the Mackenzie dike swarm in Canada and some dikes within the Scottish Tertiary). On Venus, the distinctive radial fractures and graben surrounding circular to oval features and edifices on many size scales and extending for hundreds to over a thousand km are candidates for dike emplacement in buffered conditions.
Scattering from phase-separated vesicles. I. An analytical form factor for multiple static domains
Heberle, Frederick A.; Anghel, Vinicius N. P.; Katsaras, John
2015-08-18
This is the first in a series of studies considering elastic scattering from laterally heterogeneous lipid vesicles containing multiple domains. Unique among biophysical tools, small-angle neutron scattering can in principle give detailed information about the size, shape and spatial arrangement of domains. A general theory for scattering from laterally heterogeneous vesicles is presented, and the analytical form factor for static domains with arbitrary spatial configuration is derived, including a simplification for uniformly sized round domains. The validity of the model, including series truncation effects, is assessed by comparison with simulated data obtained from a Monte Carlo method. Several aspects ofmore » the analytical solution for scattering intensity are discussed in the context of small-angle neutron scattering data, including the effect of varying domain size and number, as well as solvent contrast. Finally, the analysis indicates that effects of domain formation are most pronounced when the vesicle's average scattering length density matches that of the surrounding solvent.« less
Prenatal growth of the interorbital septum in Macaca mulatta.
Lozanoff, Scott; Doll, Sara; Hallgrimsson, Benedikt; Neufeld, Eric
2004-12-01
The interorbital septum is the portion of the anterior cranial base directly contiguous with the eyes. It is considered to be a primitive trait that has evolved independently in various primate groups as a result of ocular and olfactory convergence with concomitant encephalization. This process is hypothesized to have reduced the size of the lateral nasal capsule exposing the anterior cranial base to the ocular apparatus and thus creating an interorbital septum. The purpose of this study was to determine whether differential growth trajectories occur among the chondrocranial elements corresponding to this hypothesis. Macaca mulatta embryos from the Zingeser Collection were selected for this analysis since this primate shows a well-developed interorbital septum throughout ontogeny. Embryos between 40 and 90 days of gestation were selected from the collection and coronal sections including the eye, anterior cranial base and lateral nasal capsule were subjected to video microscopy and computerized reconstruction using SURFdriver Software. Tissue volumes were computed for these tissues while chondrocytic growth attributes were measured utilizing stereological techniques. Results showed a strong correlation between the volume of the lateral nasal capsule and anterior cranial base and these two structures showed a consistent correlation with an increasing eye volume. Chondrocytic volume density and average diameter were larger in the lateral nasal capsule while shape, numerical density and average volume did not differ between the two tissues. These data suggest if differential growth does account for a reduction of the nasal capsule compared to the central cranial base stem, it does not appear to result from differential tissue size change. However, certain cellular growth activities leading to premature chondrocytic hypertrophy may be involved.
Desai, Kapil R; Beltran, Luis S; Bencardino, Jenny T; Rosenberg, Zehava S; Petchprapa, Catherine; Steiner, German
2011-05-01
The objective of this study was to describe the anatomy and MR appearance of the spring ligament recess of the talocalcaneonavicular joint. Forty-nine MR examinations of the ankle with a spring ligament recess were prospectively collected. The size of the recess was measured. The presence of the following variables was recorded: talocalcaneonavicular joint effusion, ankle joint effusion, talar head impaction, acute lateral ankle sprain, chronic lateral ankle sprain, spring ligament tear, sinus tarsi ligament tear, talar dome osteochondral injury, and talonavicular osteoarthrosis. The Fisher exact test was performed to quantify the association of the talocalcaneonavicular effusion with the other variables. MR arthrography and dissection with histologic analysis were performed in two cadaveric ankles. Twenty-four men and 25 women (average age, 39 years; range, 21-77 years) were included in the study. The average size of the fluid collection was 0.4 × 0.8 cm (range, 0.2-0.9 × 0.4-1.5 cm). The prevalence of the measured variables was talocalcaneonavicular joint effusion, 67.3%; ankle joint effusion, 61.2%; talar head impaction, 32.7%; acute lateral ankle sprain, 28.6%; chronic lateral ankle sprain, 59.2%; spring ligament tear, 14.3%; sinus tarsi ligament tear, 12.2%; talar dome osteochondral lesion, 20.4%; and talonavicular osteoarthrosis, 18.4%. There was a higher prevalence of talar head impaction among individuals with talocalcaneonavicular joint effusion (p = 0.0522). Cadaveric study revealed communication between the talocalcaneonavicular joint and the spring ligament recess. The spring ligament recess is a synovium-lined, fluid-filled space that communicates with the talocalcaneonavicular joint. The recess should be distinguished from a tear of the plantar components of the spring ligament.
Fabrication and properties of (TbxY1-x)3Al5O12 transparent ceramics by hot isostatic pressing
NASA Astrophysics Data System (ADS)
Duan, Pingping; Liu, Peng; Xu, Xiaodong; Wang, Wei; Wan, Zhong; Zhang, Shouyi; Wang, Yinzhen; Zhang, Jian
2017-10-01
(TbxY1-x)3Al5O12 (x = 0.2, 0.5, 0.8) transparent ceramics were synthesized by a solid-state reaction and HIP. All the samples were pre-sintered at 1650 °C for 4 h in a muffle and later HIPed at 1650 °C for 3 h. (Tb0.2Y0.8)3Al5O12 transparent ceramics exhibit best microstructure with an average grain size of approximately 5.22 μm and optical transmittance of over 65% in the region of 500-1600 nm. Additionally, average grain sizes of all the samples are less than 10 μm. XRD scanning patterns indicate that only the (Tb0.8Y0.2)3Al5O12 samples have little secondary phases.
3D-HST+CANDELS: The Evolution of the Galaxy Size-Mass Distribution since z = 3
NASA Astrophysics Data System (ADS)
van der Wel, A.; Franx, M.; van Dokkum, P. G.; Skelton, R. E.; Momcheva, I. G.; Whitaker, K. E.; Brammer, G. B.; Bell, E. F.; Rix, H.-W.; Wuyts, S.; Ferguson, H. C.; Holden, B. P.; Barro, G.; Koekemoer, A. M.; Chang, Yu-Yen; McGrath, E. J.; Häussler, B.; Dekel, A.; Behroozi, P.; Fumagalli, M.; Leja, J.; Lundgren, B. F.; Maseda, M. V.; Nelson, E. J.; Wake, D. A.; Patel, S. G.; Labbé, I.; Faber, S. M.; Grogin, N. A.; Kocevski, D. D.
2014-06-01
Spectroscopic+photometric redshifts, stellar mass estimates, and rest-frame colors from the 3D-HST survey are combined with structural parameter measurements from CANDELS imaging to determine the galaxy size-mass distribution over the redshift range 0 < z < 3. Separating early- and late-type galaxies on the basis of star-formation activity, we confirm that early-type galaxies are on average smaller than late-type galaxies at all redshifts, and we find a significantly different rate of average size evolution at fixed galaxy mass, with fast evolution for the early-type population, R effvprop(1 + z)-1.48, and moderate evolution for the late-type population, R effvprop(1 + z)-0.75. The large sample size and dynamic range in both galaxy mass and redshift, in combination with the high fidelity of our measurements due to the extensive use of spectroscopic data, not only fortify previous results but also enable us to probe beyond simple average galaxy size measurements. At all redshifts the slope of the size-mass relation is shallow, R_{eff}\\propto M_*^{0.22}, for late-type galaxies with stellar mass >3 × 109 M ⊙, and steep, R_{eff}\\propto M_*^{0.75}, for early-type galaxies with stellar mass >2 × 1010 M ⊙. The intrinsic scatter is lsim0.2 dex for all galaxy types and redshifts. For late-type galaxies, the logarithmic size distribution is not symmetric but is skewed toward small sizes: at all redshifts and masses, a tail of small late-type galaxies exists that overlaps in size with the early-type galaxy population. The number density of massive (~1011 M ⊙), compact (R eff < 2 kpc) early-type galaxies increases from z = 3 to z = 1.5-2 and then strongly decreases at later cosmic times.
The effect of lateral controls in producing motion of an airplane as computed from wind-tunnel data
NASA Technical Reports Server (NTRS)
Weick, F. E.; Jones, R. T.
1976-01-01
An analytical study of the lateral controllability of an airplane has been made in which both the static rolling and yawing moments supplied by the controls and the reactions due to the inherent stability of the airplane have been taken into account. A hypothetical average airplane, embodying the essential characteristics of both the wind tunnel models and the full size test airplanes, was assumed for the study. Computations made of forced rolling and yawing motions of an F-22 airplane caused by a sudden deflection of the ailerons were found to agree well with actual measurements of these motions. The conditions following instantaneous full deflections of the lateral control have been studied, and some attention has been devoted to the controlling of complete turn maneuvers.
Fabrication of gradient optical filter containing anisotropic Bragg nanostructure.
Cho, Bomin; Um, Sungyong; Woo, Hee-Gweon; Sohn, Honglae
2011-08-01
New gradient optical filters containing asymmetric Bragg structure were prepared from the distributed Bragg reflector (DBR) porous silicon (PSi). Anisotropic DBR PSi displaying a rainbow-colored reflection was generated by using an asymmetric etching configuration. Flexible anisotropic DBR PSi composite films were obtained by casting of polymer solution onto anisotropic DBR PSi thin films. The surface and cross-sectional images images of anisotropic DBR PSi composite films obtained with cold field emission scanning electron microscope indicated that the average pore size and the thickness of porous layer decreased as the lateral distance increased. As lateral distance increased, the reflection resonance shifted to shorter wavelength.
Looe, Hui Khee; Harder, Dietrich; Poppe, Björn
2017-02-07
The lateral dose response function is a general characteristic of the volume effect of a detector used for photon dosimetry in a water phantom. It serves as the convolution kernel transforming the true absorbed dose to water profile, which would be produced within the undisturbed water phantom, into the detector-measured signal profile. The shape of the lateral dose response function characterizes (i) the volume averaging attributable to the detector's size and (ii) the disturbance of the secondary electron field associated with the deviation of the electron density of the detector material from the surrounding water. In previous work, the characteristic dependence of the shape of the lateral dose response function upon the electron density of the detector material was studied for 6 MV photons by Monte Carlo simulation of a wall-less voxel-sized detector (Looe et al 2015 Phys. Med. Biol. 60 6585-07). This study is here continued for 60 Co gamma rays and 15 MV photons in comparison with 6 MV photons. It is found (1) that throughout these photon spectra the shapes of the lateral dose response functions are retaining their characteristic dependence on the detector's electron density, and (2) that their energy-dependent changes are only moderate. This appears as a practical advantage because the lateral dose response function can then be treated as practically invariant across a clinical photon beam in spite of the known changes of the photon spectrum with increasing distance from the beam axis.
NASA Astrophysics Data System (ADS)
Shershulin, V. A.; Samoylenko, S. R.; Shenderova, O. A.; Konov, V. I.; Vlasov, I. I.
2017-02-01
The suitability of scanning near-field optical microscopy (SNOM) to image photoluminescent diamond nanoparticles with nanoscale resolution is demonstrated. Isolated diamond nanocrystals with an average size of 100 nm, containing negatively charged nitrogen-vacancy (NV-) centers, were chosen as tested material. The NV- luminescence was stimulated by continuous 532 nm laser light. Sizes of analyzed crystallites were monitored by an atomic force microscope. The lateral resolution of the order of 100 nm was reached in SNOM imaging of diamond nanoparticles using 150 nm square aperture of the probe.
Smith, Nicolina M; Segars, Larry; Kauffman, Travis; Olinger, Anthony B
2017-12-01
Atrial fibrillation (AF) is an arrhythmia which affects as many as 2.7 million Americans. AF should be treated, because it can lead to a four-to-fivefold increased risk of experiencing a stroke. The American College of Cardiology/American Heart Association guidelines for the treatment of drug refractory and symptomatic paroxysmal AF denote catheter ablation as the standard of care. The newest ablation treatment, cryoballoon, uses a cold balloon tip. The biggest risk factor associated with the cryoballoon ablation is phrenic nerve injury (PNI). The purpose of this study is to measure relevant distances from specific landmarks to the right phrenic nerve (RPN) to create a safe zone for physicians. Using 30 cadaveric specimens, we measured laterally from the right superior pulmonary vein orifice (RSPV) to the RPN at the level of the sixth thoracic vertebra and laterally from the lateral border of the sixth thoracic vertebral body (T6) to the RPN. The depth and width of the left atrium (LA) were also measured to establish a cross-sectional area of the LA. The cross-sectional area of the LA was then correlated with the averaged measurements to see if the area of the LA could be a predictor of the location of the RPN. The average distance from the RPN-RSPV was 9.6 mm (range 4.3-18.8 mm). The average RPN-T6 distance was 30.6 mm (range 13.7-49.9 mm). There was a non-significant trend that suggests as the size of the LA increases, the measured distances also increased. Using the lateral border of the sixth thoracic vertebra as a landmark, which can be viewed under fluoroscopy during the procedure, physicians can triangulate the distance to the RSPV and determine the approximate position of the RPN. Furthermore, physicians can perform a preoperative echocardiogram to determine the size of the LA to assist in determining the position of the RPN with the hopes of avoiding injury to the RPN.
Hunt, Gavin R; Corballis, Michael C; Gray, Russell D
2006-01-01
Population-level laterality is generally considered to reflect functional brain specialization. Consequently, the strength of population-level laterality in manipulatory tasks is predicted to positively correlate with task complexity. This relationship has not been investigated in tool manufacture. Here, we report the correlation between strength of laterality and design complexity in the manufacture of New Caledonian crows' three pandanus tool designs: wide, narrow and stepped designs. We documented indirect evidence of over 5800 tool manufactures on 1232 pandanus trees at 23 sites. We found that the strength of laterality in tool manufacture was correlated with design complexity in three ways: (i) the strongest effect size among the population-level edge biases for each design was for the more complex, stepped design, (ii) the strength of laterality at individual sites was on average greater for the stepped design than it was for the simpler wide and narrow, non-stepped designs, and (iii) there was a positive, but non-significant, trend for a correlation between the strength of laterality and the number of steps on a stepped tool. These three aspects together indicate that greater design complexity generally elicits stronger lateralization of crows' pandanus tool manufacture. PMID:16600891
Hunt, Gavin R; Corballis, Michael C; Gray, Russell D
2006-05-07
Population-level laterality is generally considered to reflect functional brain specialization. Consequently, the strength of population-level laterality in manipulatory tasks is predicted to positively correlate with task complexity. This relationship has not been investigated in tool manufacture. Here, we report the correlation between strength of laterality and design complexity in the manufacture of New Caledonian crows' three pandanus tool designs: wide, narrow and stepped designs. We documented indirect evidence of over 5,800 tool manufactures on 1,232 pandanus trees at 23 sites. We found that the strength of laterality in tool manufacture was correlated with design complexity in three ways: (i) the strongest effect size among the population-level edge biases for each design was for the more complex, stepped design, (ii) the strength of laterality at individual sites was on average greater for the stepped design than it was for the simpler wide and narrow, non-stepped designs, and (iii) there was a positive, but non-significant, trend for a correlation between the strength of laterality and the number of steps on a stepped tool. These three aspects together indicate that greater design complexity generally elicits stronger lateralization of crows' pandanus tool manufacture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Trofimov, A; Sharp, G C
2015-06-15
Purpose: To investigate the effects of interfractional anatomy and setup variations on plans with anterior-oblique vs. lateral beams for prostate cancer pencil beam scanning (PBS) and passive scattered (PS) proton therapy. Methods: Six patients with low/intermediate risk prostate cancer treated with PS proton therapy at our institution were selected. All patients underwent weekly verification CT scans. Implanted fiducials were used for localization, and endorectal balloons for prostate immobilization. New PBS plans with lateral beams, as well as PBS and PS plans with anterior-oblique beams (±35 deg) were created. PBS plans used two different spot sizes: ∼10mm (large) and ∼5mm (medium)more » sigma at 25cm range and optimized as single-field-uniform-dose with ∼8% non-uniformity. No range uncertainty margins were applied in PBS plans to maximize rectal sparing. Field-specific apertures were used when planning with large spots to sharpen the penumbrae. The planned dose was recomputed on each weekly CT with fiducials aligned to the simulation CT, scaled and accumulated via deformable image registration. Results: The dose volume analysis showed that although difference between planned and accumulated dose remains negligible for plans with conventional lateral beams using both PS and PBS, this is not the case for plans with anterior beams. The target coverage in anterior plans was largely degraded due to the variations in the beam path length and the absence of range margins. The average prostate D95 was reduced by 7.5/15.9% (using PS/PBS) after accumulation for anterior plans, compared with 0/0.4% for lateral plans. The average mean dose in organs-at-risk decreased by 1% for lateral and 2% for anterior plans, similarly for PS and PBS. Spot size did not affect the dose changes. Conclusion: Prostate plans using anterior beams may undergo clinically relevant interfractional dose degradation. Corrective strategies guided by in-vivo range measurements should be studied before clinical application of this technique.« less
Central Visual Prosthesis With Interface at the Lateral Geniculate Nucleus
2017-07-01
burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...currently used in the field to implant Deep Brain Stimulation electrodes. Page 4 We thus limited ourselves to using a ‘4 French’ size split sheath...this program. At this time , several approaches for realizing the complete system have been evaluated. Initially, a very simple mechanical mockup
Reinstein, Dan Z.; Archer, Timothy J.; Silverman, Ronald H.; Coleman, D. Jackson
2008-01-01
Purpose To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. Setting London Vision Clinic, London, United Kingdom. Methods A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. Results The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. Conclusion The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment. PMID:17081860
Role of Pb for Ag growth on H-passivated Si(1 0 0) surfaces
NASA Astrophysics Data System (ADS)
Mathew, S.; Satpati, B.; Joseph, B.; Dev, B. N.
2005-08-01
We have deposited Ag on hydrogen passivated Si(1 0 0) surfaces under high vacuum conditions at room temperature. The deposition, followed by annealing at 250 °C for 30 min, produced silver islands of an average lateral size 36±14 nm. Depositing a small amount of Pb prior to Ag deposition reduced the average island size to 14±5 nm. A small amount of Pb, initially present at the Ag-Si interface, is found to be segregating to the surface of Ag after annealing. Both these aspects, namely, reduction of the island size and Pb floating on the Ag surface conform to the surfactant action of Pb. Samples have been characterized by transmission electron microscopy (TEM) and Rutherford backscattering spectroscopy (RBS). A selective etching process that preferentially removes Pb, in conjunction with RBS, was used to detect surface segregation of Pb involving depth scales below the resolution of conventional RBS. The annealing and etching process leaves only smaller Ag islands on the surface with complete removal of Pb. Ag growth in the presence of Pb leads to smaller Ag islands with a narrower size distribution.
Bourassa, Kyle J; Allen, John J B; Mehl, Matthias R; Sbarra, David A
Divorce is a common stressor that is associated with increased risk for poor long-term physical and mental health. Using an experimental design, the current study examined the impact of expressive writing (EW) on average heart rate (HR), HR variability (HRV), and blood pressure (BP) 7.5 months later. Participants from a community sample of recently separated adults (N = 109) were assigned to one of three conditions: traditional EW, narrative EW, or a control writing condition, and were assessed three times for an average of 7.5 months. Each study visit included 27 minutes of physiological assessment; the primary outcomes at each assessment were mean-level HR, HRV, BP scores averaged across six different tasks. Participants in the traditional EW condition did not significantly differ from control participants in their later HR, HRV, or BP. However, relative to control participants, those in the narrative EW condition had significantly lower HR (B = -3.41, 95% confidence interval = -5.76 to -1.06, p = .004) and higher HRV 7.5 months later (B = 0.41, 95% confidence interval = 0.16 to 0.74, p = .001). When comparing narrative EW participants to those in the traditional EW and control writing as a single group, these effects remained and were moderately sized, Cohen d values of -0.61 and 0.60, respectively, and durable across all task conditions when analyzed in independent models. The writing condition groups did not differ in their later BP. Narrative EW decreased HR and increased HRV after marital separation but did not affect BP. We discuss the possible disconnect between psychology and physiology in response to EW, as well as possible future clinical applications after marital separation.
Anthun, Kjartan Sarheim; Kittelsen, Sverre Andreas Campbell; Magnussen, Jon
2017-04-01
This paper analyses productivity growth in the Norwegian hospital sector over a period of 16 years, 1999-2014. This period was characterized by a large ownership reform with subsequent hospital reorganizations and mergers. We describe how technological change, technical productivity, scale efficiency and the estimated optimal size of hospitals have evolved during this period. Hospital admissions were grouped into diagnosis-related groups using a fixed-grouper logic. Four composite outputs were defined and inputs were measured as operating costs. Productivity and efficiency were estimated with bootstrapped data envelopment analyses. Mean productivity increased by 24.6% points from 1999 to 2014, an average annual change of 1.5%. There was a substantial growth in productivity and hospital size following the ownership reform. After the reform (2003-2014), average annual growth was <0.5%. There was no evidence of technical change. Estimated optimal size was smaller than the actual size of most hospitals, yet scale efficiency was high even after hospital mergers. However, the later hospital mergers have not been followed by similar productivity growth as around time of the reform. This study addresses the issues of both cross-sectional and longitudinal comparability of case mix between hospitals, and thus provides a framework for future studies. The study adds to the discussion on optimal hospital size. Copyright © 2017 Elsevier B.V. All rights reserved.
Cho, Shin-Hyeong; Kim, Tong-Soo; Kong, Yoon; Na, Byoung-Kuk
2013-01-01
Morphological characteristics of Mesocestoides lineatus tetrathyridia collected from Chinese snakes and their adults recovered from experimental animals were studied. The tetrathyridia were detected mainly in the mesentery of 2 snake species, Agkistrodon saxatilis (25%) and Elaphe schrenckii (20%). They were 1.73 by 1.02 mm in average size and had an invaginated scolex with 4 suckers. Adult tapeworms were recovered from 2 hamsters and 1 dog, which were orally infected with 5-10 larvae each. Adults from hamsters were about 32 cm long and those from a dog were about 58 cm long. The scolex was 0.56 mm in average width with 4 suckers of 0.17 by 0.15 mm in average size. Mature proglottids measured 0.29 by 0.91 mm (av.). Ovaries and vitellaria bilobed and located in the posterior portion of proglottids. The cirrus sac was oval-shaped and located median. Testes were follicular, distributed in both lateral fields of proglottids, and 41-52 in number per proglottid. Gravid proglottids were 1.84 by 1.39 mm (av.) with a characteristic paruterine organ. Eggs were 35 by 27 µm in average size with a hexacanth embryo. These morphological characteristics of adult worms were identical with those of M. lineatus reported previously. Therefore, it has been confirmed that the tetrathyridia detected in 2 species of Chinese snakes are the metacestodes of M. lineatus, and 2 snake species, A. saxatilis and E. schrenckii, play the role of intermediate hosts. PMID:24327778
Gale, Catharine R; O'Callaghan, Finbar J; Bredow, Maria; Martyn, Christopher N
2006-10-01
We investigated the effects of head growth prenatally, during infancy, and during later periods of development on cognitive function at the ages of 4 and 8 years. We studied 633 term-born children from the Avon Longitudinal Study of Parents and Children cohort whose head circumference was measured at birth and at regular intervals thereafter. Their cognitive function was assessed with the Wechsler Preschool and Primary Scale of Intelligence at the age of 4 years and with the Wechsler Intelligence Scale for Children at the age of 8 years. Linear regression analysis was used to calculate postnatal head growth between successive time points, conditional on previous size, and to examine the relationship between head growth during different periods of development and later IQ. When the influence of head growth was distinguished for different periods, only prenatal growth and growth during infancy were associated with subsequent IQ. At 4 years, after adjustment for parental characteristics, full-scale IQ increased an average of 2.41 points for each 1-SD increase in head circumference at birth and 1.97 points for each 1-SD increase in head growth during infancy, conditional on head size at birth. At 8 years, head circumference at birth was no longer associated with IQ, but head growth during infancy remained a significant predictor, with full-scale IQ increasing an average of 1.56 points for each 1-SD increase in growth. The brain volume a child achieves by the age of 1 year helps determine later intelligence. Growth in brain volume after infancy may not compensate for poorer earlier growth.
The Effect of Impeller Type on Floc Size and Structure during Shear-Induced Flocculation
Spicer; Keller; Pratsinis
1996-12-01
The effect of impeller type and shear rate on the evolution of floc size and structure during shear-induced flocculation of polystyrene particles with aluminum sulfate is investigated by image analysis. One radial flow (six-blade Rushton turbine) and two axial flow (three-blade fluid foil, four-blade 45° pitch) impeller configurations are examined. The steady state average floc size is shown to depend on the frequency of recirculation to the impeller zone and its characteristic velocity gradient. The concepts of fractal geometry are used to characterize the floc structure. For all impellers, the two-dimensional floc fractal dimension, Dpf, increases during floc growth, indicating formation of more open structures. Later on, Dpf levels off at a steady state value as breakage becomes significant and the floc size distribution approaches steady state. The shear rate does not affect the steady state Dpf of the flocs within experimental uncertainty.
The female knee: anatomic variations.
Conley, Sheryl; Rosenberg, Aaron; Crowninshield, Roy
2007-01-01
Traditional knee implants have been designed "down the middle,"based on the combined average size and shape of male and female knee anatomy.Sex-based research in the field of orthopaedics has led to new understanding of the anatomic differences between the sexes and the associated implications for women undergoing total knee arthroplasty. Through the use of a comprehensive bone morphology atlas that utilizes novel three-dimensional computed tomography analysis technology, significant anatomic differences have been documented in the shape and size of female knees compared with male knees. This research identifies three notable anatomic differences in the female population: a less prominent anterior condyle, an increased Q angle, and a reduced medial-lateral:anterior-posterior aspect ratio.
Chai, Shi-Hong; Wang, Yating; Qiao, Yinghong; Wang, Pei; Li, Qiang; Xia, Chaofeng; Ju, Man
2018-01-01
Nowadays biological mediated syntheses of metal nanoparticles were utilized for various life caring applications. Our research group utilized Delonix elata leaf aqueous extract for the synthesis of silver nanoparticles. Further the synthesized silver nanoparticles were subjected for various characterization techniques which resulted in spherically agglomerated with biological components entrapped in it and also with average particle size of 36nm were studied and reported. Later the synthesized silver nanoparticles were subjected for wound healing property by size of measured lessions and body weight which results in better wound healing property were studied and discussed. Copyright © 2017. Published by Elsevier B.V.
[Biomechanical significance of the acetabular roof and its reaction to mechanical injury].
Domazet, N; Starović, D; Nedeljković, R
1999-01-01
The introduction of morphometry into the quantitative analysis of the bone system and functional adaptation of acetabulum to mechanical damages and injuries enabled a relatively simple and acceptable examination of morphological acetabular changes in patients with damaged hip joints. Measurements of the depth and form of acetabulum can be done by radiological methods, computerized tomography and ultrasound (1-9). The aim of the study was to obtain data on the behaviour of acetabular roof, the so-called "eyebrow", by morphometric analyses during different mechanical injuries. Clinical studies of the effect of different loads on acetabular roof were carried out in 741 patients. Radiographic findings of 400 men and 341 women were analysed. The control group was composed of 148 patients with normal hip joints. Average age of the patients was 54.7 years and that of control subjects 52.0 years. Data processing was done for all examined patients. On the basis of our measurements the average size of female "eyebrow" ranged from 24.8 mm to 31.5 mm with standard deviation of 0.93 and in men from 29.4 mm to 40.3 mm with standard deviation of 1.54. The average size in the whole population was 32.1 mm with standard deviation of 15.61. Statistical analyses revealed high correlation coefficients between the age and "eyebrow" size in men (r = 0.124; p < 0.05); it was statically in inverse proportion (Graph 1). However, in female patients the correlation coefficient was statistically significant (r = 0.060; p > 0.05). The examination of the size of collodiaphysial angle and length of "eyebrow" revealed that "eyebrow" length was in inverse proportion to the size of collodiaphysial angle (r = 0.113; p < 0.05). The average "eyebrow" length in relation to the size of collodiaphysial angle ranged from 21.3 mm to 35.2 mm with standard deviation of 1.60. There was no statistically significant correlation between the "eyebrow" size and Wiberg's angle in male (r = 0.049; p > 0.05) and female (r = 0.005; p > 0.05) patients. The "eyebrow" length was proportionally dependent on the size of the shortened extremity in all examined subjects. This dependence was statistically significant both in female (r = 0.208; p < 0.05) and male (r = 0.193; p < 0.05) patients. The study revealed that fossa acetabuli was forward and downward laterally directed. The size, form and cross-section of acetabulum changed during different loads. Dimensions and morphological changes in acetabulum showed some but unimportant changes in comparison to that in the control group. These findings are graphically presented in Figure 5 and numerically in Tables 1 and 2. The study of spatial orientation among hip joints revealed that fossa acetabuli was forward and downward laterally directed; this was in accordance with results other authors (1, 7, 9, 15, 18). There was a statistically significant difference in relation to the "eyebrow" size between patients and normal subjects (t = 3.88; p < 0.05). The average difference of "eyebrow" size was 6.892 mm. A larger "eyebrow" was found in patients with normally loaded hip. There was also a significant difference in "eyebrow" size between patients and healthy female subjects (t = 4.605; p < 0.05). A larger "eyebrow" of 8.79 mm was found in female subjects with normally loaded hip. On the basis of our study it can be concluded that the findings related to changes in acetabular roof, the so-called "eyebrow", are important in diagnosis, follow-up and therapy of pathogenetic processes of these disorders.
NASA Astrophysics Data System (ADS)
Rouholahnejad, E.; Kirchner, J. W.
2016-12-01
Evapotranspiration (ET) is a key process in land-climate interactions and affects the dynamics of the atmosphere at local and regional scales. In estimating ET, most earth system models average over considerable sub-grid heterogeneity in land surface properties, precipitation (P), and potential evapotranspiration (PET). This spatial averaging could potentially bias ET estimates, due to the nonlinearities in the underlying relationships. In addition, most earth system models ignore lateral redistribution of water within and between grid cells, which could potentially alter both local and regional ET. Here we present a first attempt to quantify the effects of spatial heterogeneity and lateral redistribution on grid-cell-averaged ET as seen from the atmosphere over heterogeneous landscapes. Using a Budyko framework to express ET as a function of P and PET, we quantify how sub-grid heterogeneity affects average ET at the scale of typical earth system model grid cells. We show that averaging over sub-grid heterogeneity in P and PET, as typical earth system models do, leads to overestimates of average ET. We use a similar approach to quantify how lateral redistribution of water could affect average ET, as seen from the atmosphere. We show that where the aridity index P/PET increases with altitude, gravitationally driven lateral redistribution will increase average ET, implying that models that neglect lateral moisture redistribution will underestimate average ET. In contrast, where the aridity index P/PET decreases with altitude, gravitationally driven lateral redistribution will decrease average ET. This approach yields a simple conceptual framework and mathematical expressions for determining whether, and how much, spatial heterogeneity and lateral redistribution can affect regional ET fluxes as seen from the atmosphere. This analysis provides the basis for quantifying heterogeneity and redistribution effects on ET at regional and continental scales, which will be the focus of future work.
Does the foveal shape influence the image formation in human eyes?
NASA Astrophysics Data System (ADS)
Frey, Katharina; Zimmerling, Beatrice; Scheibe, Patrick; Rauscher, Franziska G.; Reichenbach, Andreas; Francke, Mike; Brunner, Robert
2017-10-01
In human eyes, the maximum visual acuity correlates locally with the fovea, a shallow depression in the retina. Previous examinations have been reduced to simple geometrical fovea models derived from postmortem preparations and considering only a few superficial ray propagation aspects. In the current study, an extended and realistic analysis of ray-optical simulations for a comprehensive anatomical realistic eye model for the anterior part and realistic aspherical human foveal topographical profiles deduced from in vivo optical coherence tomography (OCT) are presented, and the refractive index step at the transition from vitreous to retinal tissue is taken into account. The optical effect of a commonly shaped (averaged) and an extraordinarily shaped foveal pit were both compared to the analysis of an assumed pure spherical boundary layer. The influence of the aperture size, wavelength, and incident angle on the spot size and shape, as well as the axial focal and lateral centroid position is investigated, and a lateral displacement of about 2 μm and an axial shift of the best focal position of less than 4 μm are found. These findings indicate only small optical effects that are laterally in the range of inter-receptor distances and axially less than the photoreceptor outer segment dimension.
PATIENT RADIATION DOSE FROM CHEST X-RAY EXAMINATIONS IN THE WEST BANK-PALESTINE.
Lahham, Adnan; Issa, Ahlam; ALMasri, Hussein
2018-02-01
Radiation doses to patients resulting from chest X-ray examinations were evaluated in four medical centers in the West Bank and East Jerusalem-Palestine. Absorbed organ and effective doses were calculated for a total of 428 adult male and female patients by using commercially available Monte Carlo based softwares; CALDOSE-X5 and PCXMC-2.0, and hermaphrodite mathematical adult phantoms. Patients were selected randomly from medical records in the time period from November 2014 to February 2015. A database of surveyed patients and exposure factors has been established and includes: patient's height, weight, age, gender, X-ray tube voltage, electric current (mAs), examination projection (anterior posterior (AP), posterior anterior (PA), lateral), X-ray tube filtration thickness in each X-ray equipment, anode angle, focus to skin distance and X-ray beam size. The average absorbed doses in the whole body from different projections were: 0.06, 0.07 and 0.11 mGy from AP, PA and lateral projections, respectively. The average effective dose for all surveyed patients was 0.14 mSv for all chest X-ray examinations and projections in the four investigated medical centers. The effect of projection geometry was also investigated. The average effective doses for AP, PA and lateral projections were 0.14, 0.07 and 0.22 mSv, respectively. The collective effective dose estimated for the exposed population was ~60 man-mSv. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Jana, Saumyadeep; Overman, Nicole; Varga, Tamas; ...
2017-09-25
Here, the effect of sub-eutectoid heat treatment on the phase transformation behavior in rolled U-10 wt.% Mo (U10Mo) foils was systematically investigated. The as-cast 5 mm thick foils were initially homogenized at 900 °C for 48 h and were hot rolled to 2 mm and later cold rolled down to 0.2 mm. Three starting microstructures were evaluated: (i) hot + cold-rolled to 0.2 mm (as-rolled condition), (ii) hot + cold-rolled to 0.2 mm + annealed at 700 °C for 1 h, and (iii) hot + cold-rolled to 0.2 mm + annealed at 1000 °C for 60 h. Annealing of as-rolledmore » materials at 700 °C resulted in small grain size (15 ± 9 μm average grain size), while annealing at 1000 °C led to very large grains (156 ± 118 μm average grain size) in rolled U10Mo foils. Later the samples were subjected to sub-eutectoid heat-treatment temperatures of 550 °C, 500 °C, and 400 °C for different durations of time starting from 1 h up to 100 h. U10Mo rolled foils went through various degrees of decomposition when subjected to the sub-eutectoid heat-treatment step and formed a lamellar microstructure through a cellular reaction mostly along the previous γ-UMo grain boundaries. The least amount of cellular reaction was observed in the large-grain microstructure at all temperatures. Conversely, a substantial amount of cellular reaction was observed in both the as-rolled and the small-grain microstructure. After 100 h of heat treatment at 500 °C, the volume fraction of the lamellar phase was found to be 4%, 22%, and 82% in large-grain, as-rolled, and small-grain samples, respectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jana, Saumyadeep; Overman, Nicole; Varga, Tamas
Here, the effect of sub-eutectoid heat treatment on the phase transformation behavior in rolled U-10 wt.% Mo (U10Mo) foils was systematically investigated. The as-cast 5 mm thick foils were initially homogenized at 900 °C for 48 h and were hot rolled to 2 mm and later cold rolled down to 0.2 mm. Three starting microstructures were evaluated: (i) hot + cold-rolled to 0.2 mm (as-rolled condition), (ii) hot + cold-rolled to 0.2 mm + annealed at 700 °C for 1 h, and (iii) hot + cold-rolled to 0.2 mm + annealed at 1000 °C for 60 h. Annealing of as-rolledmore » materials at 700 °C resulted in small grain size (15 ± 9 μm average grain size), while annealing at 1000 °C led to very large grains (156 ± 118 μm average grain size) in rolled U10Mo foils. Later the samples were subjected to sub-eutectoid heat-treatment temperatures of 550 °C, 500 °C, and 400 °C for different durations of time starting from 1 h up to 100 h. U10Mo rolled foils went through various degrees of decomposition when subjected to the sub-eutectoid heat-treatment step and formed a lamellar microstructure through a cellular reaction mostly along the previous γ-UMo grain boundaries. The least amount of cellular reaction was observed in the large-grain microstructure at all temperatures. Conversely, a substantial amount of cellular reaction was observed in both the as-rolled and the small-grain microstructure. After 100 h of heat treatment at 500 °C, the volume fraction of the lamellar phase was found to be 4%, 22%, and 82% in large-grain, as-rolled, and small-grain samples, respectively.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruan, C; Sodickson, A; Hamberg, L
2016-06-15
Purpose: Apparent patient size in CT localizers varies with localizer type and patient positioning, resulting in variation in effective mAs as guided by Tube Current Modulation (TCM). Our aim was to investigate the effects of vertical off-centering on CTDI-vol when using different localizer types and TCM strengths. Methods: A CTDI body phantom was scanned using an abdominal protocol with three TCM strengths (Siemens Definition AS40, CAREDose4D; very weak, average, very strong). Data was acquired at 11 table height positions; with phantom center at isocenter and at 10 other positions between 142mm below and 53mm above. At each position, scans weremore » acquired using 5 different localizer types: PA, AP, Lateral, PA+Lateral, and Lateral+PA. CTDI-vol was recorded for the 165 combinations of table height, localizer type, and TCM strength, and magnification factors measured from localizer images. Results: Magnification factors from AP and PA localizers ranged from 0.79–1.11 and 1.35–0.91, respectively from lowest to highest positions (highest with phantom located closest to X-ray tube), with a smaller impact when using Lateral, PA+Lateral, Lateral+PA localizer types, all of which behaved similarly. For an average TCM strength and PA localizer, CTDI-vol ranged from 75% higher to 12% lower than the isocenter value for the lowest to highest table positions, respectively. For table positions ranging from lowest to highest, CTDI-vol ranged from −23% to 17% for AP, from −8% to 0.3% for lateral and from −7% to 1% for a combination of PA and Lateral in either order. Similar behavior was found for different TCM strengths, but effects were more pronounced for very strong compared with very weak modulation strengths. Conclusion: Patient off-centering substantially impacts radiation dose, which depends on the amount of vertical offcentering and type of the localizer used. The combination of PA and Lateral localizers is most robust against effects of patient off-centering.« less
From micro- to nanomagnetic dots: evolution of the eigenmode spectrum on reducing the lateral size
NASA Astrophysics Data System (ADS)
Carlotti, G.; Gubbiotti, G.; Madami, M.; Tacchi, S.; Hartmann, F.; Emmerling, M.; Kamp, M.; Worschech, L.
2014-07-01
Brillouin light scattering experiments and micromagnetic simulations have been exploited to investigate the spectrum of thermally excited magnetic eigenmodes in 10 nm-thick elliptical Permalloy dots, when the longer axis D is scaled down from about 1000 to 100 nm. It is shown that for D larger than about 200 nm the characteristics of the spin-wave eigenmodes are dominated by dipolar energy, while for D in the range of about 100 to 200 nm exchange energy effects cause qualitative and quantitative differences in the spin-wave spectrum. In this ‘mesoscopic’ regime, the usual classification scheme, involving one fundamental mode with large average magnetization and many other modes collected in families with specific symmetries, no longer holds. Rather, one finds the simultaneous presence of two modes with ‘fundamental’ character, i.e. with a significant and comparable value of the average dynamical magnetization: the former is at larger frequency and has its maximum amplitude at the dot's centre, while the latter occurs at lower frequency and is localized at the dot's edges. Interestingly, the maximum intensity swaps from the higher frequency mode to the lower frequency one, just when the dot size is reduced from about 200 to 100 nm. This is relevant in view of the exploitation of nanodots for the design of nanomagnetic devices with lateral dimensions in the above interval, such as memory cells, logic gates, reading heads and spin-torque oscillators.
A new species of Leptolalax (Anura: Megophryidae) from northern Vietnam.
Rowley, Jodi J L; Dau, Vinh Q; Hoang, Huy D; LE, Duong T T; Cutajar, Timothy P; Nguyen, Tao T
2017-03-16
We describe a new, medium-sized Leptolalax species from Vietnam. Leptolalax petrops sp. nov. is distinguished from its congeners by a combination of having a medium-sized body (23.6-27.6 mm in 21 adult males, 30.3-47.0 mm in 17 adult females), immaculate white chest and belly, no distinct black markings on the head, highly tuberculate skin texture, toes lacking webbing and with narrow lateral fringes, and a call consisting of an average of four notes and a dominant frequency of 5.6-6.4 kHz (at 24.5-25.3 °C). Uncorrected sequence divergences between L. petrops sp. nov. and all homologous DNA sequences available for the 16S rRNA gene are >8%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dao, Trung Dung; Jeong, Han Mo, E-mail: hmjeong@mail.ulsan.ac.kr
Highlights: • Effect of raw graphite particle size on properties of GO and graphene is reported. • Size of raw graphite affects oxidation degree and chemical structure of GO. • Highly oxidized GO results in small-sized but well-exfoliated graphene. • GO properties affect reduction degree, structure, and conductivity of graphene. - Abstract: We report the effect of raw graphite size on the properties of graphite oxide and graphene prepared by thermal reduction–exfoliation of graphite oxide. Transmission electron microscope analysis shows that the lateral size of graphene becomes smaller when smaller size graphite is used. X-ray diffraction analysis confirms that graphitemore » with smaller size is more effectively oxidized, resulting in a more effective subsequent exfoliation of the obtained graphite oxide toward graphene. X-ray photoelectron spectroscopy demonstrates that reduction of the graphite oxide derived from smaller size graphite into graphene is more efficient. However, Raman analysis suggests that the average size of the in-plane sp{sup 2}-carbon domains on graphene is smaller when smaller size graphite is used. The enhanced reduction degree and the reduced size of sp{sup 2}-carbon domains contribute contradictively to the electrical conductivity of graphene when the particle size of raw graphite reduces.« less
A comparison study of size-specific dose estimate calculation methods.
Parikh, Roshni A; Wien, Michael A; Novak, Ronald D; Jordan, David W; Klahr, Paul; Soriano, Stephanie; Ciancibello, Leslie; Berlin, Sheila C
2018-01-01
The size-specific dose estimate (SSDE) has emerged as an improved metric for use by medical physicists and radiologists for estimating individual patient dose. Several methods of calculating SSDE have been described, ranging from patient thickness or attenuation-based (automated and manual) measurements to weight-based techniques. To compare the accuracy of thickness vs. weight measurement of body size to allow for the calculation of the size-specific dose estimate (SSDE) in pediatric body CT. We retrospectively identified 109 pediatric body CT examinations for SSDE calculation. We examined two automated methods measuring a series of level-specific diameters of the patient's body: method A used the effective diameter and method B used the water-equivalent diameter. Two manual methods measured patient diameter at two predetermined levels: the superior endplate of L2, where body width is typically most thin, and the superior femoral head or iliac crest (for scans that did not include the pelvis), where body width is typically most thick; method C averaged lateral measurements at these two levels from the CT projection scan, and method D averaged lateral and anteroposterior measurements at the same two levels from the axial CT images. Finally, we used body weight to characterize patient size, method E, and compared this with the various other measurement methods. Methods were compared across the entire population as well as by subgroup based on body width. Concordance correlation (ρ c ) between each of the SSDE calculation methods (methods A-E) was greater than 0.92 across the entire population, although the range was wider when analyzed by subgroup (0.42-0.99). When we compared each SSDE measurement method with CTDI vol, there was poor correlation, ρ c <0.77, with percentage differences between 20.8% and 51.0%. Automated computer algorithms are accurate and efficient in the calculation of SSDE. Manual methods based on patient thickness provide acceptable dose estimates for pediatric patients <30 cm in body width. Body weight provides a quick and practical method to identify conversion factors that can be used to estimate SSDE with reasonable accuracy in pediatric patients with body width ≥20 cm.
3D-HST + CANDELS: the Evolution of the Galaxy Size-mass Distribution Since Z=3
NASA Technical Reports Server (NTRS)
VanDerWel, A.; Franx, M.; vanDokkum, P. G.; Skelton, R. E.; Momcheva, I. G.; Whitaker, K. E.; Brammer, G. B.; Bell, E. F.; Rix, H.-W.; Wuyts, S.;
2014-01-01
Spectroscopic and photometric redshifts, stellar mass estimates, and rest-frame colors from the 3D-HST survey are combined with structural parameter measurements from CANDELS imaging to determine the galaxy size-mass distribution over the redshift (z) range 0 < z < 3. Separating early- and late-type galaxies on the basis of star-formation activity, we confirm that early-type galaxies are on average smaller than late-type galaxies at all redshifts, and find a significantly different rate of average size evolution at fixed galaxy mass, with fast evolution for the early-type population, effective radius is in proportion to (1 + z) (sup -1.48), and moderate evolution for the late-type population, effective radius is in proportion to (1 + z) (sup -0.75). The large sample size and dynamic range in both galaxy mass and redshift, in combination with the high fidelity of our measurements due to the extensive use of spectroscopic data, not only fortify previous results, but also enable us to probe beyond simple average galaxy size measurements. At all redshifts the slope of the size-mass relation is shallow, effective radius in proportion to mass of a black hole (sup 0.22), for late-type galaxies with stellar mass > 3 x 10 (sup 9) solar masses, and steep, effective radius in proportion to mass of a black hole (sup 0.75), for early-type galaxies with stellar mass > 2 x 10 (sup 10) solar masses. The intrinsic scatter is approximately or less than 0.2 decimal exponents for all galaxy types and redshifts. For late-type galaxies, the logarithmic size distribution is not symmetric, but skewed toward small sizes: at all redshifts and masses a tail of small late-type galaxies exists that overlaps in size with the early-type galaxy population. The number density of massive (approximately 10 (sup 11) solar masses), compact (effective radius less than 2 kiloparsecs) early-type galaxies increases from z = 3 to z = 1.5 - 2 and then strongly decreases at later cosmic times.
And the Last Shall Be First: Heterochrony and Compensatory Marine Growth in Sea Trout (Salmo trutta)
Marco-Rius, Francisco; Caballero, Pablo; Morán, Paloma; Garcia de Leaniz, Carlos
2012-01-01
Early juvenile growth is a good indicator of growth later in life in many species because larger than average juveniles tend to have a competitive advantage. However, for migratory species the relationship between juvenile and adult growth remains obscure. We used scale analysis to reconstruct growth trajectories of migratory sea trout (Salmo trutta) from six neighbouring populations, and compared the size individuals attained in freshwater (before migration) with their subsequent growth at sea (after migration). We also calculated the coefficient of variation (CV) to examine how much body size varied across populations and life stages. Specifically, we tested the hypothesis that the CV on body size would differ between freshwater and marine environment, perhaps reflecting different trade-offs during ontogeny. Neighbouring sea trout populations differed significantly in time spent at sea and in age-adjusted size of returning adults, but not on size of seaward migration, which was surprisingly uniform and may be indicative of strong selection pressures. The CV on body size decreased significantly over time and was highest during the first 8 months of life (when juvenile mortality is highest) and lowest during the marine phase. Size attained in freshwater was negatively related to growth during the first marine growing season, suggesting the existence of compensatory growth, whereby individuals that grow poorly in freshwater are able to catch up later at sea. Analysis of 61 datasets indicates that negative or no associations between pre- and post-migratory growth are common amongst migratory salmonids. We suggest that despite a widespread selective advantage of large body size in freshwater, freshwater growth is a poor predictor of final body size amongst migratory fish because selection may favour growth heterochrony during transitions to a novel environment, and marine compensatory growth may negate any initial size advantage acquired in freshwater. PMID:23049680
Linguistic Lateralization in Adolescents with Down Syndrome Revealed by a Dichotic Monitoring Test
ERIC Educational Resources Information Center
Shoji, Hiroaki; Koizumi, Natsuko; Ozaki, Hisaki
2009-01-01
Linguistic lateralization in 10 adolescents with Down syndrome (average age: 15.7 years), 15 adolescents with intellectual disabilities of unknown etiology (average age: 17.8 years), 2 groups of children without disabilities (11 children, average age: 4.7 years; 10 children, average age: 8.5 years), and 14 adolescents without disabilities (average…
Berend, Keith R; Kolczun, Michael C; George, Joseph W; Lombardi, Adolph V
2012-01-01
The literature suggests lateral unicompartmental knee arthroplasties are associated with low revision rates. However, there are fewer reports describing techniques for lateral unicompartmental arthroplasty and whether technique influences ROM and function compared to reports for medial unicompartmental arthroplasty. We report our indications for lateral unicompartmental arthroplasty, how we perform this procedure, and the subsequent Knee Society scores, ROM, and revision and reoperation rates. From a retrospective review of electronic records from 2004 through 2008, we identified 93 patients who had 100 lateral unicompartmental arthroplasties. Indications were complete lateral bone-on-bone arthrosis with a correctible deformity and maintenance of the medial joint space on varus stress radiographs or isolated lateral disease by diagnostic arthroscopy. Average age was 68 years. Seventy percent of patients were women. At followup, we obtained Knee Society scores and ROM. Minimum followup was 24 months (average, 39 months; range, 24-81 months). At followup, Knee Society scores averaged 46 for pain, 94 for clinical, and 89 for function, and ROM averaged 124°. Three patients had reoperations: one an open reduction and internal fixation for fracture at 2 years postoperatively, one an arthroscopy for a medial meniscal tear, and one a revision for pain. Based on our observations, we believe complete cartilage loss laterally and correctible deformity with maintenance of the medial joint on varus stress radiographs are reasonable indications for lateral unicompartmental arthroplasty. We recommend a lateral parapatellar approach can be utilized. The early reoperation and revision rates were low.
NASA Astrophysics Data System (ADS)
Chen, Zi-Yu; Li, Jian-Feng; Yu, Yong; Wang, Jia-Xiang; Li, Xiao-Ya; Peng, Qi-Xian; Zhu, Wen-Jun
2012-11-01
The influences of lateral target size on hot electron production and electromagnetic pulse emission from laser interaction with metallic targets have been investigated. Particle-in-cell simulations at high laser intensities show that the yield of hot electrons tends to increase with lateral target size, because the larger surface area reduces the electrostatic field on the target, owing to its expansion along the target surface. At lower laser intensities and longer time scales, experimental data characterizing electromagnetic pulse emission as a function of lateral target size also show target-size effects. Charge separation and a larger target tending to have a lower target potential have both been observed. The increase in radiation strength and downshift in radiation frequency with increasing lateral target size can be interpreted using a simple model of the electrical capacity of the target.
Um, Sungyong; Lee, Sung Gi; Woo, Hee-Gweon; Cho, Sungdong; Sohn, Honglae
2013-01-01
Adsorption and desorption characteristics of gradient distributed Bragg reflector (DBR) porous silicon (PSi) were investigated under the exposure of organic vapors. Gradient DBR PSi whose average pore size decreased as the lateral distance from the Pt electrode increased was generated by using an asymmetric etching configuration. The reflection resonances were measured as a function of lateral distance from a point closest to the plate Pt electrode to a position on the silicon surface. Two types of gradient DBR PSi (H- and HO-terminated gradient DBR PSi) were used in this study. The detection of volatile organic compounds (VOCs) using the gradient DBR PSi had been achieved. When the vapor of VOCs condensed in the nanopores, the gradient DBR PSi modified with hydrophobic and hydrophilic functionality exhibited different pore adsorption and desorption characteristics.
Grzyb, Tomasz; Dolinski, Dariusz
2017-01-01
The article presents studies examining whether the better than average (BTA) effect appears in opinions regarding obedience of individuals participating in an experiment conducted in the Milgram paradigm. Participants are presented with a detailed description of the experiment, asked to declare at what moment an average participant would cease their participation in the study, and then asked to declare at what moment they themselves would quit the experiment. It turned out that the participants demonstrated a strong BTA effect. This effect also concerned those who had known the results of the Milgram experiment prior to the study. Interestingly, those individuals-in contrast to naive participants-judged that the average person would remain obedient for longer, but at the same time prior familiarity with the Milgram experiment did not impact convictions as to own obedience. By the same token, the BTA effect size was larger among those who had previously heard of the Milgram experiment than those who had not. Additionally, study participants were asked to estimate the behavior of the average resident of their country (Poland), as well as of average residents of several other European countries. It turned out that in participants' judgment the average Pole would withdraw from the experiment quicker than the average Russian and average German, but later than average residents of France and England.
Grzyb, Tomasz; Dolinski, Dariusz
2017-01-01
The article presents studies examining whether the better than average (BTA) effect appears in opinions regarding obedience of individuals participating in an experiment conducted in the Milgram paradigm. Participants are presented with a detailed description of the experiment, asked to declare at what moment an average participant would cease their participation in the study, and then asked to declare at what moment they themselves would quit the experiment. It turned out that the participants demonstrated a strong BTA effect. This effect also concerned those who had known the results of the Milgram experiment prior to the study. Interestingly, those individuals—in contrast to naive participants—judged that the average person would remain obedient for longer, but at the same time prior familiarity with the Milgram experiment did not impact convictions as to own obedience. By the same token, the BTA effect size was larger among those who had previously heard of the Milgram experiment than those who had not. Additionally, study participants were asked to estimate the behavior of the average resident of their country (Poland), as well as of average residents of several other European countries. It turned out that in participants’ judgment the average Pole would withdraw from the experiment quicker than the average Russian and average German, but later than average residents of France and England. PMID:28979232
40 CFR 86.449 - Averaging provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Later New Motorcycles, General Provisions § 86.449 Averaging provisions. (a) This section describes how... credits may not be banked for use in later model years, except as specified in paragraph (j) of this... average emission levels are at or below the applicable standards in § 86.410-2006. (2) Compliance with the...
Stien, L H; Nilsson, J; Bui, S; Fosseidengen, J E; Kristiansen, T S; Øverli, Ø; Folkedal, O
2017-12-01
The present study shows that permanent melanophore spot patterns in Atlantic salmon Salmo salar make it possible to use images of the operculum to keep track of individual fish over extended periods of their life history. Post-smolt S. salar (n = 246) were initially photographed at an average mass of 98 g and again 10 months later after rearing in a sea cage, at an average mass of 3088 g. Spots that were present initially remained and were the most overt (largest) 10 months later, while new and less overt spots had developed. Visual recognition of spot size and position showed that fish with at least four initial spots were relatively easy to identify, while identifying fish with less than four spots could be challenging. An automatic image analysis method was developed and shows potential for fast match processing of large numbers of fish. The current findings promote visual recognition of opercular spots as a welfare-friendly alternative to tagging in experiments involving salmonid fishes. © The Authors. Journal of Fish Biology published by John Wiley & Sons Ltd on behalf of The Fisheries Society of the British Isles.
NEWLY QUENCHED GALAXIES AS THE CAUSE FOR THE APPARENT EVOLUTION IN AVERAGE SIZE OF THE POPULATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carollo, C. M.; Bschorr, T. J.; Lilly, S. J.
2013-08-20
We use the large COSMOS sample of galaxies to study in an internally self-consistent way the change in the number densities of quenched early-type galaxies (Q-ETGs) of a given size over the redshift interval 0.2 < z < 1 in order to study the claimed size evolution of these galaxies. In a stellar mass bin at 10{sup 10.5} < M{sub galaxy} < 10{sup 11} M{sub Sun }, we see no change in the number density of compact Q-ETGs over this redshift range, while in a higher mass bin at >10{sup 11} M{sub Sun }, where we would expect merging tomore » be more significant, we find a small decrease, by {approx}30%. In both mass bins, the increase of the median sizes of Q-ETGs with time is primarily caused by the addition to the size function of larger and more diffuse Q-ETGs. At all masses, compact Q-ETGs become systematically redder toward later epochs, with a (U - V) color difference which is consistent with a passive evolution of their stellar populations, indicating that they are a stable population that does not appreciably evolve in size. We find furthermore, at all epochs, that the larger Q-ETGs (at least in the lower mass bin) have average rest-frame colors that are systematically bluer than those of the more compact Q-ETGs, suggesting that the former are indeed younger than the latter. The idea that new, large, Q-ETGs are responsible for the observed growth in the median size of the population at a given mass is also supported by analysis of the sizes and number of the star-forming galaxies that are expected to be the progenitors of the new Q-ETGs over the same period. In the low mass bin, the new Q-ETGs appear to have {approx}30% smaller half-light radii than their star-forming progenitors. This is likely due to the fading of their disks after they cease star formation. Comparison with higher redshifts shows that the median size of newly quenched galaxies roughly scales, at constant mass, as (1 + z){sup -1}. We conclude that the dominant cause of the size evolution seen in the Q-ETG population is that the average sizes and thus stellar densities of individual Q-ETGs roughly scale with the average density of the universe at the time when they were quenched, and that subsequent size changes in individual objects, through merging or other processes, are of secondary importance, especially at masses below 10{sup 11} M{sub Sun}.« less
Wang, Ming-Hsu; Lin, Jen-Der; Chang, Chen-Nen; Chiou, Wen-Ko
2017-08-01
The aim of this study was to assess the size, angles and positional characteristics of facial anthropometry between "acromegalic" patients and control subjects. We also identify possible facial soft tissue measurements for generating discriminant functions toward acromegaly determination in males and females for acromegaly early self-awareness. This is a cross-sectional study. Subjects participating in this study included 70 patients diagnosed with acromegaly (35 females and 35 males) and 140 gender-matched control individuals. Three-dimensional facial images were collected via a camera system. Thirteen landmarks were selected. Eleven measurements from the three categories were selected and applied, including five frontal widths, three lateral depths and three lateral angular measurements. Descriptive analyses were conducted using means and standard deviations for each measurement. Univariate and multivariate discriminant function analyses were applied in order to calculate the accuracy of acromegaly detection. Patients with acromegaly exhibit soft-tissue facial enlargement and hypertrophy. Frontal widths as well as lateral depth and angle of facial changes were evident. The average accuracies of all functions for female patient detection ranged from 80.0-91.40%. The average accuracies of all functions for male patient detection were from 81.0-94.30%. The greatest anomaly observed was evidenced in the lateral angles, with greater enlargement of "nasofrontal" angles for females and greater "mentolabial" angles for males. Additionally, shapes of the lateral angles showed changes. The majority of the facial measurements proved dynamic for acromegaly patients; however, it is problematic to detect the disease with progressive body anthropometric changes. The discriminant functions of detection developed in this study could help patients, their families, medical practitioners and others to identify and track progressive facial change patterns before the possible patients go to the hospital, especially the lateral "angles" which can be calculated by relative point-to-point changes derived from 2D lateral imagery without the 3D anthropometric measurements. This study tries to provide a novel and easy method to detect acromegaly when the patients start to have awareness of abnormal appearance because of facial measurement changes, and it also suggests that undiagnosed patients be urged to go to the hospital as soon as possible for acromegaly early diagnosis.
Vertical distribution of aerosols in the vicinity of Mexico City during MILAGRO-2006 Campaign
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewandowski, P.A.; Kleinman, L.; Eichinger, W. E.
On 7 March 2006, a mobile, ground-based, vertical pointing, elastic lidar system made a North-South transect through the Mexico City basin. Column averaged, aerosol size distribution (ASD) measurements were made on the ground concurrently with the lidar measurements. The ASD ground measurements allowed calculation of the column averaged mass extinction efficiency (MEE) for the lidar system (1064 nm). The value of column averaged MEE was combined with spatially resolved lidar extinction coefficients to produce total aerosol mass concentration estimates with the resolution of the lidar (1.5 m vertical spatial and 1 s temporal). Airborne ASD measurements from DOE G-1 aircraftmore » made later in the day on 7 March 2006, allowed the evaluation of the assumptions of constant ASD with height and time used for estimating the column averaged MEE. The results showed that the aerosol loading within the basin is about twice what is observed outside of the basin. The total aerosol base concentrations observed in the basin are of the order of 200 {mu}g/m{sup 3} and the base levels outside are of the order of 100 {mu}g/m{sup 3}. The local heavy traffic events can introduce aerosol levels near the ground as high as 900 {mu}g/m{sup 3}. The article presents the methodology for estimating aerosol mass concentration from mobile, ground-based lidar measurements in combination with aerosol size distribution measurements. An uncertainty analysis of the methodology is also presented.« less
DNA methylation intratumor heterogeneity in localized lung adenocarcinomas.
Quek, Kelly; Li, Jun; Estecio, Marcos; Zhang, Jiexin; Fujimoto, Junya; Roarty, Emily; Little, Latasha; Chow, Chi-Wan; Song, Xingzhi; Behrens, Carmen; Chen, Taiping; William, William N; Swisher, Stephen; Heymach, John; Wistuba, Ignacio; Zhang, Jianhua; Futreal, Andrew; Zhang, Jianjun
2017-03-28
Cancers are composed of cells with distinct molecular and phenotypic features within a given tumor, a phenomenon termed intratumor heterogeneity (ITH). Previously, we have demonstrated genomic ITH in localized lung adenocarcinomas; however, the nature of methylation ITH in lung cancers has not been well investigated. In this study, we generated methylation profiles of 48 spatially separated tumor regions from 11 localized lung adenocarcinomas and their matched normal lung tissues using Illumina Infinium Human Methylation 450K BeadChip array. We observed methylation ITH within the same tumors, but to a much less extent compared to inter-individual heterogeneity. On average, 25% of all differentially methylated probes compared to matched normal lung tissues were shared by all regions from the same tumors. This is in contrast to somatic mutations, of which approximately 77% were shared events amongst all regions of individual tumors, suggesting that while the majority of somatic mutations were early clonal events, the tumor-specific DNA methylation might be associated with later branched evolution of these 11 tumors. Furthermore, our data showed that a higher extent of DNA methylation ITH was associated with larger tumor size (average Euclidean distance of 35.64 (> 3cm, median size) versus 27.24 (<= 3cm), p = 0.014), advanced age (average Euclidean distance of 34.95 (above 65) verse 28.06 (below 65), p = 0.046) and increased risk of postsurgical recurrence (average Euclidean distance of 35.65 (relapsed patients) versus 29.03 (patients without relapsed), p = 0.039).
Ghadyani, Hamid R.; Bastien, Adam D.; Lutz, Nicholas N.; Hepel, Jaroslaw T.
2015-01-01
Purpose Noninvasive image-guided breast brachytherapy delivers conformal HDR 192Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Material and methods The model assumed the breast was under planar stress with values of 30 kPa for Young's modulus and 0.3 for Poisson's ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target–applicator combinations. Conclusions The model exhibited skin dose trends that matched MC-generated benchmarking results within 2% and clinical observations over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over a range of clinical circumstances. These findings highlight the need for careful target localization and accurate identification of compression thickness and target offset. PMID:25829938
Artmann, L; Larsen, H J; Sørensen, H B; Christensen, I J; Kjaer, I
2010-06-01
To analyze the interrelationship between incisor width, deviations in the dentition and available space in the dental arch in palatally and labially located maxillary ectopic canine cases. Size: On dental casts from 69 patients (mean age 13 years 6 months) the mesiodistal widths of each premolar, canine and incisor were measured and compared with normal standards. Dental deviations: Based on panoramic radiographs from the same patients the dentitions were grouped accordingly: Group I: normal morphology; Group IIa: deviations in the dentition within the maxillary incisors only; Group IIb: deviations in the dentition in general. Descriptive statistics for the tooth sizes and dental deviations were presented by the mean and 95% confidence limits for the mean and the p-value for the T-statistic. Space: Space was expresses by subtracting the total tooth sizes of incisors, canines and premolars from the length of the arch segments. Size of lateral maxillary incisor: The widths of the lateral incisors were significantly different in groups I, IIa and IIb (p=0.016) and in cases with labially located ectopic canines on average 0.65 (95% CI:0.25-1.05, p=0.0019) broader than lateral incisors in cases with palatally located ectopic canines. Space: Least available space was observed in cases with labially located canines. The linear model did show a difference between palatally and labially located ectopic canines (p=0.03). Space related to deviations in the dentition: When space in the dental arch was related to dental deviations (groups I, IIa and IIb), the cases in group IIb with palatally located canines had significantly more space compared with I and IIa. Two subgroups of palatally located ectopic maxillary canine cases based on registration of space, incisor width and deviations in the morphology of the dentition were identified.
[Interposition arthrodesis of the ankle].
Vienne, Patrick
2005-10-01
Bony fusion of the ankle in a functionally favorable position for restitution of a painless weight bearing while avoiding a leg length discrepancy. Disabling, painful osteoarthritis of the ankle with extensive bone defect secondary to trauma, infection, or serious deformities such as congenital malformations or diabetic osteoarthropathies. Acute joint infection. Severe arterial occlusive disease of the involved limb. Lateral approach to the distal fibula. Fibular osteotomy 7 cm proximal to the tip of the lateral malleolus and posterior flipping of the distal fibula. Exposure of the ankle. Removal of all articular cartilage and debridement of the bone defect. Determination of the size of the defect and harvesting of a corresponding tricortical bone graft from the iliac crest. Also harvesting of autogenous cancellous bone either from the iliac crest or from the lateral part of the proximal tibia. Insertion of the tricortical bone graft and filling of the remaining defect with cancellous bone. Fixation with three 6.5-mm titanium lag screws. Depending on the extent of the defect additional stabilization of the bone graft with a titanium plate. Fixation of the lateral fibula on talus and tibia with two 3.5-mm titanium screws for additional support. Wound closure in layers. Split below-knee cast with the ankle in neutral position. Between January 2002 and January 2004 this technique was used in five patients with extensive bone defects (four women, one man, average age 57 years [42-77 years]). No intra- or early postoperative complications. The AOFAS (American Orthopedic Foot and Ankle Society) Score was improved from 23 points preoperatively to 76 points postoperatively (average follow-up time of 25 months). Two patients developed a nonunion and underwent a revision with an ankle arthrodesis nail. A valgus malposition after arthrodesis in one patient was corrected with a supramalleolar osteotomy.
Bai, Zhibiao; Gao, Shichang; Hu, Zhenming; Liang, Anlin
2018-03-20
The present study was performed to compare the clinical efficacy of lateral plate and lateral and medial double-plating fixation of distal femoral fractures and explore the indication of lateral and medial double-plating fixation of the distal femoral fractures. From March 2006 to April 2014, 48 and 12 cases of distal femoral fractures were treated with lateral plate (single plate) and lateral and medial plates (double plates), respectively. During the surgery, after setting the lateral plate for the distal femoral fractures, if the varus stress test of the knee was positive and the lateral collateral ligament rupture was excluded, lateral and medial double-plating fixation was used for the stability of the fragments. All the patients were followed up at an average period of 15.9 months. The average operation time, the intraoperative hemorrhage and the fracture union time of the two groups were compared. One year after operation, knee function was evaluated by the Kolmert's standard. There was no significant difference in the average operation time, intraoperative hemorrhage, fracture healing time and excellent and good rates of postoperative knee function between two groups. Positive Varus stress test during operation can be an indication for lateral and medial double-plating fixation of distal femoral fractures.
SU-F-T-478: Effect of Deconvolution in Analysis of Mega Voltage Photon Beam Profiles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muthukumaran, M; Manigandan, D; Murali, V
2016-06-15
Purpose: To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers. Methods: 0.125cc Semi-Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in-plane and cross-plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateralmore » and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied. Results: After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles. Conclusion: The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.« less
Kim, Hyong-Nyun; Suh, Dong-Hyun; Hwang, Pil-Sung; Yu, Sun-O; Park, Yong-Wook
2011-04-01
The purpose of this study was to evaluate the clinical results of distal chevron osteotomy performed in conjunction with selective lateral soft tissue release. The criterion for doing a lateral soft tissue release was assessed by determining the ease and completeness of passive hallux valgus correction at the time of surgery. Between August 2005 and November 2007, 48 feet in 43 patients classified as having mild to moderate hallux valgus were retrospectively studied. Distal chevron osteotomy without lateral soft tissue release was performed in 26 cases (Group 1) when passive correction of the hallux valgus deformity was possible. Distal chevron osteotomy with lateral soft tissue release was performed in 22 cases (Group 2) when passive correction was not possible. Average followup was 23 (range, 12 to 28) months. Clinical results were assessed using radiographic parameters [hallux valgus angle (HVA), first and second intermetatarsal angle (1,2 IMA)], AOFAS scale and patient's subjective satisfaction. For Group 1: the average correction of HVA was 12.8 degrees, the average correction of IMA was 4.7 degrees, and the AOFAS score improved an average of 29.2 points at the last followup. Thirteen patients were very satisfied and ten patients were satisfied with the results. No patient was dissatisfied. For Group 2: the average correction of HVA was 19.1 degrees, the average correction of IMA was 7 degrees and AOFAS score improved at an average of 31.8 points at the last followup. Twelve patients were very satisfied, seven patients were satisfied and one patient, who had stiffness of the first metatarsophalangeal joint, was dissatisfied with the result. Distal chevron osteotomy with selective lateral soft tissue release based on the ability to passively correct the hallux valgus deformity lead to safe and stable correction.
Sharma, Gaurav; Gn, Kiran Kumar; Khatri, Kavin; Singh, Ravijot; Gamanagatti, Shivanand; Sharma, Vijay
2017-02-01
In this study we describe the morphology of the posteromedial fragment in pertrochanteric fractures using 3D CT scans and answer two questions 1) Do differences exist between the 3D CT appearances of posteromedial fragments and the depictions made in the AO classification 2) Does the posteromedial fragment affect stability in pertrochanteric fractures, in terms of fracture collapse? Preoperative CT scans of eight 31-A1 and fifty 31-A2 fractures were analysed. The presence of PM fragment, its fragmentation, greater trochanter (GT) involvement, lesser trochanter (LT) fragment size (in terms of its posterior and medial extent as well as LT length), LT fragment displacement (in terms of medial displacement and rotation) were determined. All fractures were treated with a DHS. Fracture collapse was determined on postoperative radiographs. The relationship between fracture collapse and patient factors including age, gender, fracture type (A1 versus A2), characteristics of the posteromedial fragment, and the presence of a lateral wall fracture were determined. Three out of eight 31-A1 fractures demonstrated a separate GT fragment (three part fracture). Out of the 50 31-A2 fractures, 12 had a single PM fragment, which included the LT and GT in continuity. The more common four part fractures seem to form by further fragmentation of this basic form. In A2 fractures, the GT was almost always broken and the broken fragment comprised a mean 56% of normal GT. The LT fragment involved an average of 74% of the posterior wall, and an average of 36% of the medial wall of the proximal femur. Larger LT fragments were less displaced as compared to smaller fragments. Univariate regression analyses revealed that fracture collapse was significantly correlated with fracture type (A1 versus A2, p 0.036), GT size (p 0.002) and the presence of a lateral wall fracture (p<0.001). This study revealed some important differences between the 3D CT appearances and AO classification of pertrochanteric fractures. Further, neither fragmentation of the posteromedial fragment, nor the size of the lesser trochanter fragment was found to predict stability in pertrochanteric fractures. A perioperative lateral wall fracture is the main determinant of stability in these fractures. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lateral Variability of Lava flow Morphologies in the Deccan Traps Large Igneous Province (India)
NASA Astrophysics Data System (ADS)
Vanderkluysen, L.; Rader, E. L.; Self, S.; Clarke, A. B.; Sheth, H.; Moyer, D. K.
2016-12-01
In continental flood basalt provinces (CFBs), lava flow morphologies have traditionally been classified in two distinct groups recognizable in the field, expressing two different modes of lava flow emplacement mechanisms: (a) compound lava flow fields dominated by meter-sized pāhoehoe toes and lobes; and (b) inflated sheet lobes tens to hundreds of meters in width and meters to tens of meters in height. Temporal transitions between these two emplacement styles have been recognized in many mafic large igneous provinces worldwide and seem to be a fundamental feature of CFBs. However, lateral variations in these morphologies remain poorly studied and understood. In the Deccan CFB of India, two principal hypotheses have been proposed to account for possible lateral variations in lava flow facies: that smaller toes and lobes occur in distal regions of flow fields, representing breakouts at the edges of larger inflated lavas; or on the contrary that smaller toes and lobes represent proximal facies. We conducted a field study focusing on two of the Deccan's formations, the Khandala and the Poladpur, located in the middle and upper sections of the province's defined chemostratigraphy. We studied nine sections along a 600 km long E-W transect, with the easternmost sections representing the most distal outcrops, ≥ 500 km away from inferred vents. The Khandala Formation is traditionally described as a sequence of three thick inflated sheet lobes in the well-exposed sections of the western Deccan. However, in the central Deccan, we find the Khandala to be much thicker overall, with half of its thickness dominated by small, meter-sized toes and lobes. Inflated sheet lobes of the Khandala are thinner on average in the central Deccan than further to the east or west. We document this transition as occurring progressively in outcrops only 80 km apart. In the Poladpur, the average thickness of inflated sheet lobes increases in distal outcrops of the eastern Deccan. We interpret these results as an indication that smaller, meter-sized toes and lobes are indicative of proximal facies, whereas the thickest (> 10 m) inflated sheet lobes are the most likely to reach the far edges of the province. Analogue experiments are currently under way to test the relative importance of eruption parameters in the development of these morphologies.
House, Robert; Wells, LaRue
1973-01-01
Growth of trout-perch (Percopsis omiscomaycus) in the first 2 years of life was somewhat slower in southeastern Lake Michigan (average length at end of second year, 83 mm) than in Lower Red Lake, Minnesota (90 mm), but considerably faster than in Lake Superior (58 mm); size differences in later years were slightly less pronounced. Young fish began growing earlier in the year (some before June 20) than older ones (as late as August). Females tended to live longer than males, as they do in Lower Red Lake and Lake Superior. Trout-perch spawned from late June or early July until late September, somewhat later than in Lower Red Lake (May to August) or Lake Erie (June to August). Fecundity was similar to that in Lake Erie; mature females 94-146 mm long contained from 126 to 1329 yolked eggs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Provisions § 89.204 Averaging. (a) Requirements for Tier 1 engines rated at or above 37 kW. A manufacturer... credits obtained through trading. (b) Requirements for Tier 2 and later engines rated at or above 37 kW and Tier 1 and later engines rated under 37 kW. A manufacturer may use averaging to offset an emission...
NASA Astrophysics Data System (ADS)
Clotet, Xavier; Santucci, Stéphane; Ortín, Jordi
2016-01-01
We report the results of an experimental investigation of the spatiotemporal dynamics of stable imbibition fronts in a disordered medium, in the regime of capillary disorder, for a wide range of experimental conditions. We have used silicone oils of various viscosities μ and nearly identical oil-air surface tension, and forced them to slowly invade a model open fracture at very different flow rates v . In this second part of the study we have carried out a scale-dependent statistical analysis of the front dynamics. We have specifically analyzed the influence of μ and v on the statistical properties of the velocity Vℓ, the spatial average of the local front velocities over a window of lateral size ℓ . We have varied ℓ from the local scale defined by our spatial resolution up to the lateral system size L . Even though the imposed flow rate is constant, the signals Vℓ(t ) present very strong fluctuations which evolve systematically with the parameters μ , v , and ℓ . We have verified that the non-Gaussian fluctuations of the global velocity Vℓ(t ) are very well described by a generalized Gumbel statistics. The asymmetric shape and the exponential tail of those distributions are controlled by the number of effective degrees of freedom of the imbibition fronts, given by Neff=ℓ /ℓc (the ratio of the lateral size of the measuring window ℓ to the correlation length ℓc˜1 /√{μ v } ). The large correlated excursions of Vℓ(t ) correspond to global avalanches, which reflect extra displacements of the imbibition fronts. We show that global avalanches are power-law distributed, both in sizes and durations, with robustly defined exponents—independent of μ , v , and ℓ . Nevertheless, the exponential upper cutoffs of the distributions evolve systematically with those parameters. We have found, moreover, that maximum sizes ξS and maximum durations ξT of global avalanches are not controlled by the same mechanism. While ξS are also determined by ℓ /ℓc , like the amplitude fluctuations of Vℓ(t ) , ξT and the temporal correlations of Vℓ(t ) evolve much more strongly with imposed flow rate v than with fluid viscosity μ .
Effects of porcine pancreatic enzymes on the pancreas of hamsters. Part 2: carcinogenesis studies.
Nozawa, Fumiaki; Yalniz, Mehmet; Saruc, Murat; Standop, Jens; Egami, Hiroshi; Pour, Parviz M
2012-09-10
Our previous study suggested that porcine pancreatic extract in hamsters with peripheral insulin resistance, normalizes insulin output, islet size and pancreatic DNA synthetic rate. It also inhibited the growth of human pancreatic cancer cells in nude mice. To examine the potential value of the porcine pancreatic extract in controlling pancreatic carcinogenesis in this model, the present experiment was performed. Hamsters were fed a high fat diet and four weeks later when insulin resistance emerges, they were divided into two groups. One group received 1 g/kg BW of porcine pancreatic extract in drinking water and the other group received tap water. One week later, when insulin output normalizes in porcine pancreatic extract-treated hamsters, a single subcutaneous injection of N-nitrosobis-(2-oxopropyl) amine (BOP) at a dose of 40 mg/kg BW was given to all hamsters. The experiment was terminated at 43 weeks after the porcine pancreatic extract treatment. The number and size of pancreatic tumors, blood glucose, insulin, amylase and lipase levels, the average size of islets and the number of insulin cells/islets were determined. The incidence of pancreatic cancer was significantly lower in the porcine pancreatic extract group (P=0.043), as well as the plasma insulin level and the size of the islets in the porcine pancreatic extract group were significantly lower (P<0.001) than in the control group. No significantly differences were found in the glucose level between the groups. These results show that porcine pancreatic extract has a potential to inhibit pancreatic cancer growth.
THE SIZE DIFFERENCE BETWEEN RED AND BLUE GLOBULAR CLUSTERS IS NOT DUE TO PROJECTION EFFECTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb, Jeremy J.; Harris, William E.; Sills, Alison, E-mail: webbjj@mcmaster.ca
Metal-rich (red) globular clusters in massive galaxies are, on average, smaller than metal-poor (blue) globular clusters. One of the possible explanations for this phenomenon is that the two populations of clusters have different spatial distributions. We test this idea by comparing clusters observed in unusually deep, high signal-to-noise images of M87 with a simulated globular cluster population in which the red and blue clusters have different spatial distributions, matching the observations. We compare the overall distribution of cluster effective radii as well as the relationship between effective radius and galactocentric distance for both the observed and simulated red and bluemore » sub-populations. We find that the different spatial distributions does not produce a significant size difference between the red and blue sub-populations as a whole or at a given galactocentric distance. These results suggest that the size difference between red and blue globular clusters is likely due to differences during formation or later evolution.« less
Landsat image and sample design for water reservoirs (Rapel dam Central Chile).
Lavanderos, L; Pozo, M E; Pattillo, C; Miranda, H
1990-01-01
Spatial heterogeneity of the Rapel reservoir surface waters is analyzed through Landsat images. The image digital counts are used with the aim or developing an aprioristic quantitative sample design.Natural horizontal stratification of the Rapel Reservoir (Central Chile) is produced mainly by suspended solids. The spatial heterogeneity conditions of the reservoir for the Spring 86-Summer 87 period were determined by qualitative analysis and image processing of the MSS Landsat, bands 1 and 3. The space-time variations of the different observed strata obtained with multitemporal image analysis.A random stratified sample design (r.s.s.d) was developed, based on the digital counts statistical analysis. Strata population size as well as the average, variance and sampling size of the digital counts were obtained by the r.s.s.d method.Stratification determined by analysis of satellite images were later correlated with ground data. Though the stratification of the reservoir is constant over time, the shape and size of the strata varys.
Gutiérrez, Sergio; Comiskey, Charles A; Luo, Zong-Ping; Pupello, Derek R; Frankle, Mark A
2008-12-01
Evaluations of functional outcomes of reverse shoulder arthroplasty have revealed variable improvements in the range of motion and high rates of scapular notching. The purpose of this study was to systematically examine the impact of surgical factors (location of the glenosphere on the glenoid and tilt angle of the glenosphere on the glenoid) and implant-related factors (implant size, center-of-rotation offset, and humeral neck-shaft angle) on impingement-free abduction motion. A computer model was developed to virtually simulate abduction/adduction motion and its dependence on five surgical and implant-related factors. Three conditions were tested for each factor, resulting in a total of 243 simulated combinations. The overall motion was determined from 0 degrees of abduction until maximum abduction, which would be limited by impingement of the humerosocket on the scapula. In those combinations in which 0 degrees of abduction could not be achieved, the adduction deficit was recorded. The largest average increase in the range of impingement-free abduction motion resulted from a more lateral center-of-rotation offset: the average increase was 31.9 degrees with a change in the center-of-rotation offset from 0 to 10 mm, and this change resulted in an increase in abduction motion in eighty of the eighty-one combinations. The position of the glenosphere on the glenoid was associated with the second largest average increase in abduction motion (28.1 degrees when the glenosphere position was changed from superior to inferior, with the change resulting in an increase in seventy-one of the eighty-one combinations). These factors were followed by glenosphere tilt, humeral neck-shaft angle, and prosthetic size in terms of their effects on abduction motion. The largest effect in terms of avoiding an adduction deficit was provided by a humeral neck-shaft angle of 130 degrees (the deficit was avoided in forty-nine of the eighty-one combinations in which this angle was used), followed by an inferior glenosphere position on the glenoid (deficit avoided in forty-one combinations), a 10-mm lateral offset of the center of rotation, inferior tilt of the glenosphere, and a 42-mm-diameter prosthetic size. An understanding of a hierarchy of prosthetic design and implantation factors may be important to maximize impingement-free abduction motion as well as to avoid inferior impingement.
Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L
2004-03-01
We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18 x 7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186+/-8 mm and 147+/-8 mm, respectively, with an average HU value of 209+/-40. An infant head was found to be equivalent to a water cylinder with a radius of approximately 60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is approximately 20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors.
Measuring size evolution of distant, faint galaxies in the radio regime
NASA Astrophysics Data System (ADS)
Lindroos, L.; Knudsen, K. K.; Stanley, F.; Muxlow, T. W. B.; Beswick, R. J.; Conway, J.; Radcliffe, J. F.; Wrigley, N.
2018-05-01
We measure the evolution of sizes for star-forming galaxies as seen in 1.4 GHz continuum radio for z = 0-3. The measurements are based on combined VLA+MERLIN data of the Hubble Deep Field, and using a uv-stacking algorithm combined with model fitting to estimate the average sizes of galaxies. A sample of ˜1000 star-forming galaxies is selected from optical and near-infrared catalogues, with stellar masses M⊙ ≈ 1010-1011 M⊙ and photometric redshifts 0-3. The median sizes are parametrized for stellar mass M* = 5 × 1010 M⊙ as R_e = A× {}(H(z)/H(1.5))^{α _z}. We find that the median radio sizes evolve towards larger sizes at later times with αz = -1.1 ± 0.6, and A (the median size at z ≈ 1.5) is found to be 0.26^'' ± 0.07^'' or 2.3±0.6 kpc. The measured radio sizes are typically a factor of 2 smaller than those measure in the optical, and are also smaller than the typical H α sizes in the literature. This indicates that star formation, as traced by the radio continuum, is typically concentrated towards the centre of galaxies, for the sampled redshift range. Furthermore, the discrepancy of measured sizes from different tracers of star formation, indicates the need for models of size evolution to adopt a multiwavelength approach in the measurement of the sizes star-forming regions.
NASA Astrophysics Data System (ADS)
Ward, Thomas; Wey, Chi; Glidden, Robert; Hosoi, A. E.; Bertozzi, A. L.
2009-08-01
The flow of viscous, particle-laden wetting thin films on an inclined plane is studied experimentally as the particle concentration is increased to the maximum packing limit. The slurry is a non-neutrally buoyant mixture of silicone oil and either solid glass beads or glass bubbles. At low concentrations (ϕ <0.45), the elapsed time versus average front position scales with the exponent predicted by Huppert [Nature (London) 300, 427 (1982)]. At higher concentrations, the average front position still scales with the exponent predicted by Huppert on some time interval, but there are observable deviations due to internal motion of the particles. At the larger concentration values and at later times, the departure from Huppert is seen to strongly depend on total slurry volume VT, inclination angle α, density difference, and particle size range.
Silicon crystallization in nanodot arrays organized by block copolymer lithography
NASA Astrophysics Data System (ADS)
Perego, Michele; Andreozzi, Andrea; Seguini, Gabriele; Schamm-Chardon, Sylvie; Castro, Celia; BenAssayag, Gerard
2014-12-01
Asymmetric polystyrene- b-polymethylmethacrylate (PS- b-PMMA) block copolymers are used to fabricate nanoporous PS templates with different pore diameter depending on the specific substrate neutralization protocol. The resulting polymeric templates are used as masks for the subsequent deposition of a thin ( h = 5 nm) amorphous Si layer by electron beam evaporation. After removal of the polymeric film and of the silicon excess, well-defined hexagonally packed amorphous Si nanodots are formed on the substrate. Their average diameter ( d < 20 nm), density (1.2 × 1011 cm-2), and lateral distribution closely mimic the original nanoporous template. Upon capping with SiO2 and high temperature annealing (1050 °C, N2), each amorphous Si nanodot rearranges in agglomerates of Si nanocrystals ( d < 4 nm). The average diameter and shape of these Si nanocrystals strongly depend on the size of the initial Si nanodot.
Dilation of the oropharynx via selective stimulation of the hypoglossal nerve
NASA Astrophysics Data System (ADS)
Huang, Jingtao; Sahin, Mesut; Durand, Dominique M.
2005-12-01
The functional effects of selective hypoglossal nerve (HG) stimulation with a multi-contact peripheral nerve electrode were assessed using images of the upper airways and the tongue in anesthetized beagles. A biphasic pulse train of 50 Hz frequency and 2 s duration was applied through each one of the tripolar contact sets of the nerve electrode while the pharyngeal images were acquired into a computer. The stimulation current was limited to 20% above the activation threshold for maximum selectivity. The images showed that various contact sets could generate several different activation patterns of the tongue muscles resulting in medial and/or lateral dilation and closing of the airways at the tongue root. Some of these patterns translated into an increase in the oropharyngeal size while others did not have any effect. The pharyngeal sizes were not statistically different during stimulation either between the two different positions of the head (30° and 60°), or when the lateral contacts were compared with the medial ones. The contacts that had the least effect generated an average of 53 ± 15% pharyngeal dilation relative to the best contacts, indicating that the results are marginally sensitive to the contact position around the HG nerve trunk. These results suggest that selective HG nerve stimulation can be a useful technique to produce multiple tongue activation patterns that can dilate the pharynx. This may in turn increase the size of the patient population who can benefit from HG nerve stimulation as a treatment method for obstructive sleep apnea.
Craniofacial structure variations in patients with palatal anomalies and velopharyngeal dysfunction.
Nachmani, Ariela; Aizenbud, Dror; Nageris, Ben; Emodi, Omri; Kassem, Firas
2017-02-01
Cephalometric evaluation of craniofacial and craniopharyngeal morphology is important for understanding the factors affecting velopharyngeal dysfunction (VPD) in patients with palatal anomalies. In this study, 366 patients with VPD were retrospectively stratified into cleft lip and palate (CLP), cleft palate (CP), submucous cleft palate (SMCP), occult submucous cleft palate (OSMCP), and non-CP groups. Lateral cephalometrics were used to assess craniofacial, craniopharyngeal, and velopharyngeal anatomy. The average craniofacial morphology in patients with VPD differed significantly according to the type of palatal anomaly. The non-CP and OSMCP groups differed from the CLP, CP, and SMCP groups in nasopharyngeal size and shape as depicted by a larger ANS-Ptm-Ve angle, a smaller S-N-Ba and NBa-PP angles, and a shorter linear value of S-Ar in the non-CP group. The CLP and CP groups had shorter ANS-Ptm, shorter Ptm-P, and smaller SNA and SNB angles. VPD patients with overt clefts have different skeletal and nasopharyngeal shapes compared to non-CP and OSMCP. Velopharyngeal function assessment should include the size and shape of the nasopharyngeal space in addition to the size and the activity of the velum and posterior and lateral walls of the nasopharynx. This should enable a more precise understanding of VPD pathology, and lead to improvements in the posterior pharyngeal flap technique in order to obtain better postoperative speech outcomes after surgical management of velopharyngeal dysfunction. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Radiographic Assessment of the Robert and Lateral Views in Trapeziometacarpal Osteoarthrosis.
Oheb, Jonathan; Lansinger, Yuri; Jansen, Joshua A; Nguyen, Jimmy Q; Porembski, Margaret A; Rayan, Ghazi M
2015-01-01
To evaluate the effectiveness of the Robert view in assessing trapeziometacarpal arthrosis and to compare the accuracy of the Robert and lateral views in staging trapeziometacarpal (TM) joint arthrosis. Patient demographics were obtained. Four participating raters reviewed 62 randomly selected thumb x-rays of patients presenting with thumb TM joint pain. Lateral and Robert-hyperpronation views were assessed using an analysis of 13 criteria. X-rays of 62 thumbs for 58 patients were evaluated. The average patients' age was 64 (47-87) and 51 (80%) were females. The majority of X-rays evaluated fell into stage 3. Stage 2 was the second most common level of arthritis encountered and the least was stage 1. More osteophytes were encountered in the trapezium than metacarpal on both the Robert and lateral views. The Robert view was superior in detecting osteophytes on the trapezium than the lateral view. Osteophyte size varied from 1.7 to 2 mm. The lateral view displayed 61 cases with dorsal metacarpal subluxation (98%). The Robert view displayed 48 cases (77%) with radial metacarpal subluxation and 9 cases (15%) with ulnar metacarpal subluxation. Thumb metacarpal adduction deformity was encountered on the lateral view in 20 cases (32%) whereas on the Robert view it was encountered in 14 cases (23%). Subchondral sclerosis was encountered on the Robert view in 56 thumbs (90%) while it was seen on the lateral view in 52 thumbs (84%). Pantrapezial arthritis involving the STT joint was encountered equally in 16 cases (26%) on the Robert view and the lateral views. The study found a moderate level of interrater reliability on both the lateral and Robert views. With the exception of osteophytes encountered on the trapezium versus the metacarpal, there were no other statistically significant findings. This study confirms that each of the Robert and lateral views offer unique information and combining both views enhances the ability to assess radiographic disease severity, and should be the recommended set of X-rays for assessing TM osteoarthrosis.
Providing cost-effective treatment of hard-to-heal wounds in the community through use of NPWT.
Hampton, Jane
2015-06-01
The treatment of non-healing wounds accounts for a high proportion of wound care costs. Advanced technology treatments, such as negative pressure wound therapy (NPWT), could be cost-effective if they result in faster healing. The objective of this study is to assess the effect on healing and the cost-effectiveness of a single-use NPWT (i.e PICO by Smith & Nephew) when used on hard-to-heal wounds in a community setting. This was a cohort case study in which wounds were treated with NWPT for 2 weeks. Wounds were assessed every 2-4 weeks to a healed state. The weekly cost of treatment prior to intervention, that is, the products used and nurse time, were compared with treatment costs associated with NWPT and after a return to standard treatment. The study included 9 patients with leg ulcers or pressure ulcers that had been slow healing or non-healing for at least 6 weeks. While treated with NPWT, the average weekly reduction in wound size was 21%. The wound size achieved with NPWT was reached on average 10 weeks earlier than predicted. The increased healing rate continued after PICO stopped and 5 wounds healed on average 8 weeks later. Frequency of dressing changes fell from 4 times weekly at baseline to 2 times a week with NPWT and to 1.8 after NPWT stopped. Weekly cost of treatment with NPWT was, on average, 1.6 times higher than the baseline, but fell to 3 times less when NPWT stopped owing to the reduction in dressing changes. The amount of change in healing rate was considerably higher than the increase in costs associated with NPWT. NWPT is a cost-effective treatment for hard-to-heal wounds. Wounds decreased in size and healed more quickly under NWPT treatment than under standard treatment. Additional NPWT costs can be quickly offset by faster healing and a shortened treatment period.
Abrisham, Seyed Mohammad J.; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R.; Gadimi, Mahdie; Omidvar, Fereshte
2017-01-01
Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Results: Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kVp), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. Conclusion: The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20). PMID:28656161
Abrisham, Seyed Mohammad J; Bouzarjomehri, Fathollah; Nafisi-Moghadam, Reza; Sobhan, Mohammad R; Gadimi, Mahdie; Omidvar, Fereshte
2017-05-01
This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and precision of the system was confirmed according to the acceptance testing. The same procedure was used for 18 patients referred for lumbar spine digital radiology (overall 36 images). Although radiation fields in the EOS were almost twice of that in digital radiology, and the average peak tube voltage (kV p ), current supply to the tube (mA), and the average size and age of the patients referred for EOS imaging were greater than digital radiology, however, the average DAP in EOS was 1/5 of that in digital radiology system. Also, the average dose in the EOS was about 1/20 of that in digital radiology. The patient dose in EOS imaging system was lower in comparison with digital radiology (1/20).
Laparoscopic lateral pancreaticojejunostomy: a new remedy for an old ailment.
Palanivelu, C; Shetty, R; Jani, K; Rajan, P S; Sendhilkumar, K; Parthasarthi, R; Malladi, V
2006-03-01
Lateral pancreaticojejunostomy is considered as the standard surgery for chronic pancreatitis. Yet there are very few reports of this procedure being done laparoscopically. We present our experience with laparoscopic lateral pancreaticojejunostomy till date and describe our technique. Since 1997, we have done 12 laparoscopic lateral pancreatojejunostomies. There were 9 females and 3 males and the average age was 29.3 years. The indication for surgery in all patients was intractable abdominal pain and significant weight loss. Additionally, two patients were also suffering from pancreatic ascites. The average diameter of the pancreatic duct was 14.7 mm. We used a four-port technique. All surgeries were completed without any conversion to open surgery. Post-operatively, there were no major morbidity and nil mortality. The average operating time was 172 minutes. Post-operative stay was short (average 5 days) and on median follow-up of 4.4 years, 83.3% patients had complete pain relief while 16.7% had partial relief. All patients had significant weight gain. Laparoscopic lateral pancreaticojejunostomy is safe, effective and feasible in experience hands. Mastery of intracorporeal knotting and suturing techniques is mandatory before embarking on this surgery.
Bottom sediments and nutrients in the tidal Potomac system, Maryland and Virginia
Glenn, Jerry L.
1988-01-01
The characteristics and distributions of near-surface bottom sediments and of nutrients in the sediments provide information on modern sediment and nutrient sources, sedimentation environments, and geochemical reactions in the tidal Potomac system, Maryland and Virginia. This information is fundamental to an improved understanding of sedimentation and eutrophication problems in the tidal Potomac system. The tidal Potomac system consists of 1,230 square kilometers of intertidal to subtidal Potomac mainstem and tributary streambed from the heads-of-tides to Chesapeake Bay. Tidal Potomac sediments are dominantly silt and clay except in local areas. An average sediment sample is about two-thirds silt and clay (fine) particles and one-third sand (coarse) particles. The mean of the median size of all samples is 6.60 phi, or 0.010 millimeters. Sorting generally is poor and the average sediment is skewed toward the fine tail of the size-distribution curve. Mean particle-size measures have large standard deviations. Among geomorphic units, two distinctly different size populations are found; fine (median phi about 9), and poorly sorted (sorting about 3) sediments in the channel and the smooth flat, and coarse (median phi about 2), and well sorted (sorting about 1) sediments in the shoreline flat and the irregular slope. Among mainstem hydrologic divisions, an average sediment from the river and the estuary division is coarser and more variable than an average sediment from the transition division. Substantial concentrations of total carbon, total nitrogen, and total phosphorus, and limited amounts of inorganic carbon, ammonia nitrogen and nitrite plus nitrate nitrogen occur in tidal Potomac sediments. An average tidal Potomac sediment sample weighing 1 kilogram contains about 21,000 milligrams of total carbon, 2,400 milligrams of total nitrogen, 1,200 milligrams of total phosphorus, 600 milligrams of inorganic carbon, 170 milligrams of ammonia nitrogen, and 2 milligrams of nitrite plus nitrate nitrogen. Total carbon, nitrogen, and phosphorus have an average ratio by weight of 18:2:1 and an average ratio by atoms of 94:8:1. Nutrient concentrations and nutrient ratios have large ranges and standard deviations. Nutrient concentrations usually are closely related to particle size; large concentrations are characteristic of fine sediments in the channel and the smooth flat, and small concentrations are typical of coarse sediments in the shoreline flat and the irregular slope. Concentrations typically decrease from the river division to the estuary division. Mainstem and tributaries show no statistically significant difference in mean particle-size measures or mean nutrient concentrations. Tributaries do not contribute large quantities of sediment with diverse texture or nutrient content to the Potomac mainstem. Particle-size measures and nutrient concentrations in the mainstem are significantly related to hydrologic divisions and geomorphic units; that is, particle size and nutrients vary significantly along and across the Potomac mainstem. Lateral variations in particle size and nutrient content are more pronounced and contribute more to significant relations than longitudinal variations contribute. The mean values for the median particle size and for the percentage of sand indicate significant variations among hydrologic divisions for samples from a geomorphic unit, and among geomorphic units, for samples from a hydrologic division. Sediments of channels and smooth flats in the river division commonly are coarser than sediments of channels and smooth flats in the transition and the estuary divisions. Shoreline flats in the estuary division are coarser than shoreline flats in the river division. Shoreline flats and irregular slopes in each hydrologic division generally are significantly coarser than channels and smooth flats. Relations between particle-size measures and geomorphic units show progressively larger cor
[Significance of lateral release in the therapy of patellar chondromalacia].
Krüger, T; Göbel, F; Huschenbett, A; Hein, W
2002-10-01
A retrospective study was performed in 26 patients who underwent an operation for femoro-patellar pain due to a patellar chondromalacia with or without minor patellar dislocation/lateral pressure syndrome. The average age of the patients was 28.5 (15-39) years. 22 of the 26 patients revealed minor chondral damages of the stages 1 and 2 according to Outerbridge. In 12 patients ("lavage" group), an arthroscopic joint debridement only was carried out, while an additional open, lateral retinaculum release was made in 14 patients ("lateral release" group). The patella's distance of dislocation according to Hepp was reduced on an average of 3.0 (0-7) mm (p = 0.0019). The results of Bentley's score obtained during the follow-up interval on an average of 30.1 (9 to 60) months were almost identical for both groups. "Good" and "very good" results were achieved in the "lavage" group (83.3 %) and "lateral release" group (78.6 % of the patients). Lateral release should be used in cases of patellar decentration between 5 and 10 mm and adequate pain symptoms. The post-operative distance of dislocation should be less than 5 mm. Under such conditions and with minor chondral damage, a combined approach by using an arthroscopic joint debridement and open lateral release is promising to treat a patellar dislocation/lateral pressure syndrome.
NASA Astrophysics Data System (ADS)
McGee, David; Marcantonio, Franco; McManus, Jerry F.; Winckler, Gisela
2010-10-01
The constant-flux proxies excess 230Th ( 230Th xs) and extraterrestrial 3He ( 3He ET) are commonly used to calculate sedimentary mass accumulation rates and to quantify lateral advection of sediment at core sites. In settings with significant lateral input or removal of sediment, these calculations depend on the assumption that concentrations of 230Th xs and 3He ET are the same in both advected sediment and sediment falling through the water column above the core site. Sediment redistribution is known to fractionate grain sizes, preferentially transporting fine grains; though relatively few studies have examined the grain size distribution of 230Th xs and 3He ET, presently available data indicate that both are concentrated in fine grains, suggesting that fractionation during advection may bias accumulation rate and lateral advection estimates based on these proxies. In this study, we evaluate the behavior of 230Th xs and 3He ET in Holocene and last glacial samples from two cores from the Blake Ridge, a drift deposit in the western North Atlantic. At the end of the last glacial period, both cores received large amounts of laterally transported sediment enriched in fine-grained material. We find that accumulation rates calculated by normalization to 230Th and 3He are internally consistent despite large spatial and temporal differences in sediment advection. Our analyses of grain size fractions indicate that ~ 70% of 3He ET-bearing grains are in the < 20 μm fraction, with roughly equal amounts in the < 4 and 4-20 μm fractions. 230Th xs is concentrated in <4-μm grains relative to 4- to 20-μm grains by approximately a factor of 2 in Holocene samples and by a much larger factor (averaging a factor of 10) in glacial samples. Despite these enrichments of both constant-flux proxies in fine particles, the fidelity of 230Th- and 3He-based accumulation rate estimates appears to be preserved even in settings with extreme sediment redistribution, perhaps due to the cohesive behavior of fine particles in marine settings.
Nelson, Peter A.; McDonald, Richard R.; Nelson, Jonathan M.; Dietrich, William E.
2015-01-01
Riverbeds frequently display a spatial structure where the sediment mixture composing the channel bed has been sorted into discrete patches of similar grain size. Even though patches are a fundamental feature in gravel bed rivers, we have little understanding of how patches form, evolve, and interact. Here we present a two-dimensional morphodynamic model that is used to examine in greater detail the mechanisms responsible for the development of forced bed surface patches and the coevolution of bed morphology and bed surface patchiness. The model computes the depth-averaged channel hydrodynamics, mixed-grain-size sediment transport, and bed evolution by coupling the river morphodynamic model Flow and Sediment Transport with Morphological Evolution of Channels (FaSTMECH) with a transport relation for gravel mixtures and the mixed-grain-size Exner equation using the active layer assumption. To test the model, we use it to simulate a flume experiment in which the bed developed a sequence of alternate bars and temporally and spatially persistent forced patches with a general pattern of coarse bar tops and fine pools. Cross-stream sediment flux causes sediment to be exported off of bars and imported into pools at a rate that balances downstream gradients in the streamwise sediment transport rate, allowing quasi-steady bar-pool topography to persist. The relative importance of lateral gravitational forces on the cross-stream component of sediment transport is a primary control on the amplitude of the bars. Because boundary shear stress declines as flow shoals over the bars, the lateral sediment transport is increasingly size selective and leads to the development of coarse bar tops and fine pools.
O'Brien, Daniel J; Dolan, James; Pencea, Stefan; Schupp, Nicholas; Sawakuchi, Gabriel O
2018-02-01
The purpose of this study was to acquire beam data for an MR-linac, with and without a 1.5 T magnetic field, by using a variety of commercially available detectors to assess their relative response in the magnetic field. The impact of the magnetic field on the measured dose distribution was also assessed. An MR-safe 3D scanning water phantom was used to measure output factors, depth dose curves, and off-axis profiles for various depths and for field sizes between 2 × 2 cm 2 and 22 × 22 cm 2 for an Elekta MR-linac beam with the orthogonal 1.5 T magnetic field on or off. An on-board MV portal imaging system was used to ensure that the reproducibility of the detector position, both with and without the magnetic field, was within 0.1 mm. The detectors used included ionization chambers with large, medium, and small sensitive volumes; a diamond detector; a shielded diode; and an unshielded diode. The offset of the effective point of measurement of the ionization chambers was found to be reduced by at least half for each chamber in the direction parallel with the beam. A lateral shift of similar magnitude was also introduced to the chambers' effective point of measurement toward the average direction of the Lorentz force. A similar lateral shift (but in the opposite direction) was also observed for the diamond and diode detectors. The measured lateral shift in the dose distribution was independent of depth and field size for each detector for fields between 2 × 2 cm 2 and 10 × 10 cm 2 . The shielded diode significantly misrepresented the dose distribution in the lateral direction perpendicular to the magnetic field, making it seem more symmetric. The percentage depth dose was generally found to be lower with the magnetic field than without, but this difference was reduced as field size increased. The depth of maximum dose showed little dependence on field size in the presence of the magnetic field, with values from 1.2 cm to 1.3 cm between the 2 × 2 cm 2 and 22 × 22 cm 2 fields. Output factors measured in the magnetic field at the center of the beam profile produced a larger spread of values between detectors for fields smaller than 10 × 10 cm 2 (with a spread of 2% at 3 × 3 cm 2 ). The spread of values was more consistent when the output factors were measured at the point of peak intensity of the lateral dose distribution instead (except for the shielded diode which differed by up to 2% depending on field size). The magnetic field of the MR-linac alters the effective point of measurement of ionization chambers, shifting it both downstream and laterally. Shielded diodes produce incorrect and misleading dose profiles. The output factor measured at the point of peak intensity in the lateral dose distribution is more robust than the conventional output factor (measured at central axis). Diodes are not recommended for output factor measurements in the magnetic field. © 2017 American Association of Physicists in Medicine.
Detection of submicron-sized raft-like domains in membranes by small-angle neutron scattering
NASA Astrophysics Data System (ADS)
Pencer, J.; Mills, T.; Anghel, V.; Krueger, S.; Epand, R. M.; Katsaras, J.
2005-12-01
Using coarse grained models of heterogeneous vesicles we demonstrate the potential for small-angle neutron scattering (SANS) to detect and distinguish between two different categories of lateral segregation: 1) unilamellar vesicles (ULV) containing a single domain and 2) the formation of several small domains or “clusters” (~10 nm in radius) on a ULV. Exploiting the unique sensitivity of neutron scattering to differences between hydrogen and deuterium, we show that the liquid ordered (lo) DPPC-rich phase can be selectively labeled using chain deuterated dipalymitoyl phosphatidylcholine (dDPPC), which greatly facilitates the use of SANS to detect membrane domains. SANS experiments are then performed in order to detect and characterize, on nanometer length scales, lateral heterogeneities, or so-called “rafts”, in ~30 nm radius low polydispersity ULV made up of ternary mixtures of phospholipids and cholesterol. For 1:1:1 DOPC:DPPC:cholesterol (DDC) ULV we find evidence for the formation of lateral heterogeneities on cooling below 30 °C. These heterogeneities do not appear when DOPC is replaced by SOPC. Fits to the experimental data using coarse grained models show that, at room temperature, DDC ULV each exhibit approximately 30 domains with average radii of ~10 nm.
Tuhtan, Jeffrey A; Fuentes-Perez, Juan Francisco; Toming, Gert; Schneider, Matthias; Schwarzenberger, Richard; Schletterer, Martin; Kruusmaa, Maarja
2018-05-25
The lateral line system provides fish with advanced mechanoreception over a wide range of flow conditions. Inspired by the abilities of their biological counterparts, artificial lateral lines have been developed and tested exclusively under laboratory settings. Motivated by the lack of flow measurements taken in the field which consider fluid-body interactions, we built a fish-shaped lateral line probe. The device is outfitted with 11 high-speed (2.5 kHz) time-synchronized pressure transducers, and designed to capture and classify flows in fish passage structures. A total of 252 field measurements, each with a sample size of 132 000 discrete sensor readings were recorded in the slots and across the pools of vertical slot fishways. These data were used to estimate the time-averaged flow velocity (R 2 = 0.952), which represents the most common metric to assess fishway flows. The significant contribution of this work is the creation and application of hydrodynamic signatures generated by the spatial distribution of pressure fluctuations on the fish-shaped body. The signatures are based on the collection of the pressure fluctuations' probability distributions, and it is shown that they can be used to automatically classify distinct flow regions within the pools of three different vertical slot fishways. For the first time, field data from operational fishway measurements are sampled and classified using an artificial lateral line, providing a completely new source of bioinspired flow information.
Kinetics of cross-slope running.
Willwacher, Steffen; Fischer, Katina Mira; Benker, Rita; Dill, Stephan; Brüggemann, Gert-Peter
2013-11-15
The purpose of the present study was to identify kinetic responses to running on mediolaterally elevated (cross-sloped) running surfaces. Ground reaction forces (GRFs), GRF lever arms and joint moment characteristics of 19 male runners were analyzed when running at 3.5m/s on a custom-made, tiltable runway. Tilt angles of 3° and 6° for medial and lateral elevation were analyzed using a 10 camera Vicon Nexus system and a force platform. The point of force application of the GRF showed a systematic shift in the order of 1-1.5cm to either the lateral or medial aspect of the foot for lateral or medial inclinations, respectively. Consequently, the strongest significant effects of tilt orientation and level on joint kinetics and ground reaction force lever arms were identified at the ankle, knee and hip joint in the frontal plane of movement. External eversion moments at the ankle were significantly increased by 35% for 6° of lateral elevation and decreased by 16% for 6° of medial elevation. Altering the cross-slope of the running surface changed the pattern of ankle joint moments in the transversal plane. Effect sizes were on average larger for laterally elevated conditions, indicating a higher sensitivity of kinetic parameters to this kind of surface tilt. These alterations in joint kinetics should be considered in the choice of the running environment, especially for specific risk groups, like runners in rehabilitation processes. © 2013 Elsevier Ltd. All rights reserved.
Mahowald, Kyle; Fedorenko, Evelina
2016-10-01
The majority of functional neuroimaging investigations aim to characterize an average human brain. However, another important goal of cognitive neuroscience is to understand the ways in which individuals differ from one another and the significance of these differences. This latter goal is given special weight by the recent reconceptualization of neurological disorders where sharp boundaries are no longer drawn either between health and neuropsychiatric and neurodevelopmental disorders, or among different disorders (e.g., Insel et al., 2010). Consequently, even the variability in the healthy population can inform our understanding of brain disorders. However, because the use of functional neural markers is still in its infancy, no consensus presently exists about which measures (e.g., effect size?, extent of activation?, degree of lateralization?) are the best ones to use. We here attempt to address this question with respect to one large-scale neural system: the set of brain regions in the frontal and temporal cortices that jointly support high-level linguistic processing (e.g., Binder et al., 1997; Fedorenko, Hsieh, Nieto-Castanon, Whitfield-Gabrieli, & Kanwisher, 2010). In particular, using data from 150 individuals all of whom had performed a language "localizer" task contrasting sentences and nonword sequences (Fedorenko et al., 2010), we: a) characterize the distributions of the values for four key neural measures of language activity (region effect sizes, region volumes, lateralization based on effect sizes, and lateralization based on volumes); b) test the reliability of these measures in a subset of 32 individuals who were scanned across two sessions; c) evaluate the relationship among the different regions of the language system; and d) evaluate the relationship among the different neural measures. Based on our results, we provide some recommendations for future studies of brain-behavior and brain-genes relationships. Although some of our conclusions are specific to the language system, others (e.g., the fact that effect-size-based measures tend to be more reliable than volume-based measures) are likely to generalize to the rest of the brain. Copyright © 2016 Elsevier Inc. All rights reserved.
Holland, Dominic; Chang, Linda; Ernst, Thomas M; Curran, Megan; Buchthal, Steven D; Alicata, Daniel; Skranes, Jon; Johansen, Heather; Hernandez, Antonette; Yamakawa, Robyn; Kuperman, Joshua M; Dale, Anders M
2014-10-01
The very early postnatal period witnesses extraordinary rates of growth, but structural brain development in this period has largely not been explored longitudinally. Such assessment may be key in detecting and treating the earliest signs of neurodevelopmental disorders. To assess structural growth trajectories and rates of change in the whole brain and regions of interest in infants during the first 3 months after birth. Serial structural T1-weighted and/or T2-weighted magnetic resonance images were obtained for 211 time points from 87 healthy term-born or term-equivalent preterm-born infants, aged 2 to 90 days, between October 5, 2007, and June 12, 2013. We segmented whole-brain and multiple subcortical regions of interest using a novel application of Bayesian-based methods. We modeled growth and rate of growth trajectories nonparametrically and assessed left-right asymmetries and sexual dimorphisms. Whole-brain volume at birth was approximately one-third of healthy elderly brain volume, and did not differ significantly between male and female infants (347 388 mm3 and 335 509 mm3, respectively, P = .12). The growth rate was approximately 1%/d, slowing to 0.4%/d by the end of the first 3 months, when the brain reached just more than half of elderly adult brain volume. Overall growth in the first 90 days was 64%. There was a significant age-by-sex effect leading to widening separation in brain sizes with age between male and female infants (with male infants growing faster than females by 200.4 mm3/d, SE = 67.2, P = .003). Longer gestation was associated with larger brain size (2215 mm3/d, SE = 284, P = 4×10-13). The expected brain size of an infant born one week earlier than average was 5% smaller than average; at 90 days it will not have caught up, being 2% smaller than average. The cerebellum grew at the highest rate, more than doubling in 90 days, and the hippocampus grew at the slowest rate, increasing by 47% in 90 days. There was left-right asymmetry in multiple regions of interest, particularly the lateral ventricles where the left was larger than the right by 462 mm3 on average (approximately 5% of lateral ventricular volume at 2 months). We calculated volume-by-age percentile plots for assessing individual development. Normative trajectories for early postnatal brain structural development can be determined from magnetic resonance imaging and could be used to improve the detection of deviant maturational patterns indicative of neurodevelopmental disorders.
Structural Growth Trajectories and Rates of Change in the First 3 Months of Infant Brain Development
Holland, Dominic; Chang, Linda; Ernst, Thomas M.; Curran, Megan; Buchthal, Steven D.; Alicata, Daniel; Skranes, Jon; Johansen, Heather; Hernandez, Antonette; Yamakawa, Robyn; Kuperman, Joshua M.; Dale, Anders M.
2016-01-01
IMPORTANCE The very early postnatal period witnesses extraordinary rates of growth, but structural brain development in this period has largely not been explored longitudinally. Such assessment may be key in detecting and treating the earliest signs of neurodevelopmental disorders. OBJECTIVE To assess structural growth trajectories and rates of change in the whole brain and regions of interest in infants during the first 3 months after birth. DESIGN, SETTING, AND PARTICIPANTS Serial structural T1-weighted and/or T2-weighted magnetic resonance images were obtained for 211 time points from 87 healthy term-born or term-equivalent preterm-born infants, aged 2 to 90 days, between October 5, 2007, and June 12, 2013. MAIN OUTCOMES AND MEASURES We segmented whole-brain and multiple subcortical regions of interest using a novel application of Bayesian-based methods. We modeled growth and rate of growth trajectories nonparametrically and assessed left-right asymmetries and sexual dimorphisms. RESULTS Whole-brain volume at birth was approximately one-third of healthy elderly brain volume, and did not differ significantly between male and female infants (347 388 mm3 and 335 509 mm3, respectively, P = .12). The growth rate was approximately 1%/d, slowing to 0.4%/d by the end of the first 3 months, when the brain reached just more than half of elderly adult brain volume. Overall growth in the first 90 days was 64%. There was a significant age-by-sex effect leading to widening separation in brain sizes with age between male and female infants (with male infants growing faster than females by 200.4 mm3/d, SE = 67.2, P = .003). Longer gestation was associated with larger brain size (2215 mm3/d, SE = 284, P = 4×10−13). The expected brain size of an infant born one week earlier than average was 5% smaller than average; at 90 days it will not have caught up, being 2% smaller than average. The cerebellum grew at the highest rate, more than doubling in 90 days, and the hippocampus grew at the slowest rate, increasing by 47% in 90 days. There was left-right asymmetry in multiple regions of interest, particularly the lateral ventricles where the left was larger than the right by 462 mm3 on average (approximately 5% of lateral ventricular volume at 2 months). We calculated volume-by-age percentile plots for assessing individual development. CONCLUSIONS AND RELEVANCE Normative trajectories for early postnatal brain structural development can be determined from magnetic resonance imaging and could be used to improve the detection of deviant maturational patterns indicative of neurodevelopmental disorders. PMID:25111045
Corstjens, Paul L A M; Hoekstra, Pytsje T; de Dood, Claudia J; van Dam, Govert J
2017-11-01
Methodological applications of the high sensitivity genus-specific Schistosoma CAA strip test, allowing detection of single worm active infections (ultimate sensitivity), are discussed for efficient utilization in sample pooling strategies. Besides relevant cost reduction, pooling of samples rather than individual testing can provide valuable data for large scale mapping, surveillance, and monitoring. The laboratory-based CAA strip test utilizes luminescent quantitative up-converting phosphor (UCP) reporter particles and a rapid user-friendly lateral flow (LF) assay format. The test includes a sample preparation step that permits virtually unlimited sample concentration with urine, reaching ultimate sensitivity (single worm detection) at 100% specificity. This facilitates testing large urine pools from many individuals with minimal loss of sensitivity and specificity. The test determines the average CAA level of the individuals in the pool thus indicating overall worm burden and prevalence. When requiring test results at the individual level, smaller pools need to be analysed with the pool-size based on expected prevalence or when unknown, on the average CAA level of a larger group; CAA negative pools do not require individual test results and thus reduce the number of tests. Straightforward pooling strategies indicate that at sub-population level the CAA strip test is an efficient assay for general mapping, identification of hotspots, determination of stratified infection levels, and accurate monitoring of mass drug administrations (MDA). At the individual level, the number of tests can be reduced i.e. in low endemic settings as the pool size can be increased as opposed to prevalence decrease. At the sub-population level, average CAA concentrations determined in urine pools can be an appropriate measure indicating worm burden. Pooling strategies allowing this type of large scale testing are feasible with the various CAA strip test formats and do not affect sensitivity and specificity. It allows cost efficient stratified testing and monitoring of worm burden at the sub-population level, ideally for large-scale surveillance generating hard data for performance of MDA programs and strategic planning when moving towards transmission-stop and elimination.
Malignant tumors associated with ovarian mature teratoma: A single institution experience.
Trabzonlu, Levent; Durmaz, Guray; Vural, Cigdem; Muezzinoglu, Bahar; Corakci, Aydin
2017-05-01
The aims of this study are to present demographical features of cases diagnosed with malignant tumor associated with ovarian mature teratoma and to analyze histopathological features and clinical follow up of these tumors. Single-institution retrospective charts were reviewed to identify all cases of ovarian mature teratoma diagnosed from 1998 to 2015. Clinicopathological parameters that were analyzed include age, tumor size, tumor stage, histological type, laterality, IOC diagnosis and whether or not patient has received adjuvant chemotherapy. A total of 218 ovarian mature teratoma cases were identified during the study period. Of the 218 ovarian mature teratoma specimens, eight (3.7%) exhibited malignant tumors. The average age for cases of malignancy associated with ovarian mature teratoma was 44.6 years. The average size of tumors was 10.36cm. On final pathology, histological types of tumors were as follows: two cases each of squamous cell carcinoma and papillary thyroid carcinoma; one case each of mucinous adenocarcinoma, metastatic adenocarcinoma, sebaceous carcinoma and oligodendroglioma. Only one patient with Stage IIB tumor died of disease. One patient was alive with metastatic disease two months after initial diagnosis. Mean and median follow-up times were 64.1 and 49 months, respectively. An ovarian mass that has characteristics of a teratoma in a postmenopausal patient should alert for malignancy -regardless of tumor size. IOC is a valuable tool for the detection of malignancy and should be requested to determine the modality of surgical approach. Copyright © 2017 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Feng Zengzhao; Zhang Yongsheng; Jin Zhenkui
1998-06-01
Dolostones are well developed in the Ordovician Majiagou Group in the Ordos area, North China Platform. These dolostones can be divided into four types: mud-sized to silt-sized crystalline dolostones not associated with gypsum and halite beds (type I), mud-sized to silt-sized crystalline dolostones associated with gypsum and halite beds (type II), mottled silt-sized to very fine sand-sized crystalline dolostones (fine saccharoidal dolostones) (type III), and mottled coarse silt-sized to fine sand-sized crystalline dolostones (coarse saccharoidal dolostones) (type IV). Type I dolostones consist of mud-sized to silt-sized dolomite crystals. Laminar stromatolites, ripple marks, mud cracks and birdseyes are common. Such dolostones are not associated with gypsum and halite beds, but lath-shaped pseudomorphs after gypsum are common. The ordering of dolomites averages 0.59, and molar concentration of CaCO 3 averages 51.44%. δ13C averages -0.8‰ (PDB Standard), δ18O averages -2.9‰, δCe averages 0.83. The above characteristics suggest that type I dolostones result from penecontemporaneous dolomitization of lime mud on supratidal flat environments by hypersaline sea water. Type II dolostones mainly consist of mud-sized to silt-sized dolomite crystals. They are commonly well laminated but show no desiccation structures. Such dolostones are intercalated within laminated gypsum and halite beds or are intermixed with them. Such dolostones resulted from dolomitization of lime mud by hypersaline sea water in gypsum and halite precipitating lagoons. Type III dolostones consist of coarse silt-sized to very fine sand-sized dolomite crystals. They commonly underlie type I dolostones and grade downwards to dolomite-mottled limestones and pure limestones. The ordering of dolomites averages 0.63, and molar concentration of CaCO 3 averages 55.64%. δ13C averages -0.2‰, δ18O averages -3.3‰, δCe averages 1.24. Such dolostones resulted from reflux dolomitization by hypersaline sea water. Type IV dolostones consist of coarse-silt-sized to fine-sand-sized dolomite crystals. In such dolostones, stylolites are cut by dolomite crystals. Fluid inclusions are present, and the homogenization temperature commonly ranges from 104°C to 203°C. The ordering of dolomites averages 0.85, and molar concentration of CaCO 3 averages 50.65%. δ13C averages 0.6‰, δ18O averages -7.4‰, and δCe averages 1.16. Such dolostones resulted from deep burial dolomitization. In the Ordos area, type I and II dolostones modified by palaeokarstification are the major gas reservoir rocks of the Ordos Gas Field at present. Type IV dolostones show good reservoir characteristics and may also be potential reservoir rocks.
NASA Astrophysics Data System (ADS)
Yan, Yuan-Lin; Liu, Xin-Guo; Dai, Zhong-Ying; Ma, Yuan-Yuan; He, Peng-Bo; Shen, Guo-Sheng; Ji, Teng-Fei; Zhang, Hui; Li, Qiang
2017-09-01
The three-dimensional (3D) spot-scanning method is one of the most commonly used irradiation methods in charged particle beam radiotherapy. Generally, spot-scanning beam delivery utilizes the same size pencil beam to irradiate the tumor targets. Here we propose a spot-scanning beam delivery method with laterally- and longitudinally-mixed size pencil beams for heavy ion radiotherapy. This uses pencil beams with a bigger spot size in the lateral direction and wider mini spread-out Bragg peak (mini-SOBP) to irradiate the inner part of a target volume, and pencil beams with a smaller spot size in the lateral direction and narrower mini-SOBP to irradiate the peripheral part of the target volume. Instead of being controlled by the accelerator, the lateral size of the pencil beam was adjusted by inserting Ta scatterers in the beam delivery line. The longitudinal size of the pencil beam (i.e. the width of the mini-SOBP) was adjusted by tilting mini ridge filters along the beam direction. The new spot-scanning beam delivery using carbon ions was investigated theoretically and compared with traditional spot-scanning beam delivery. Our results show that the new spot-scanning beam delivery has smaller lateral penumbra, steeper distal dose fall-off and the dose homogeneity (1-standard deviation/mean) in the target volume is better than 95%. Supported by Key Project of National Natural Science Foundation of China (U1232207), National Key Technology Support Program of the Ministry of Science and Technology of China (2015BAI01B11), National Key Research and Development Program of the Ministry of Science and Technology of China (2016YFC0904602) and National Natural Science Foundation of China (11075191, 11205217, 11475231, 11505249)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michalak, Gregory; Grimes, Joshua; Fletcher, Joel
2016-01-15
Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kVmore » beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.« less
Michalak, Gregory; Grimes, Joshua; Fletcher, Joel; Halaweish, Ahmed; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia
2016-01-01
The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. The authors' report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.
Synthesis of transparent dispersions of aluminium hydroxide nanoparticles
NASA Astrophysics Data System (ADS)
Chen, Bo; Wang, Jie-Xin; Wang, Dan; Zeng, Xiao-Fei; Clarke, Stuart M.; Chen, Jian-Feng
2018-07-01
Transparent dispersions of inorganic nanoparticles are attractive materials in many fields. However, a facile method for preparing such dispersions of aluminium hydroxide nanoparticles is yet to be realized. Here, we report a direct reactive method to prepare transparent dispersions of pseudo-boehmite nanoparticles (1 wt%) without any surface modification, and with an average particle size of 80 nm in length and 10 nm in width, as well as excellent optical transparency over 94% in the visible range. Furthermore, transparent dispersions of boehmite nanoparticles (1.5 wt%) were also achieved after an additional hydrothermal treatment. However, the optical transparency of dispersions decreased with the rise of hydrothermal temperature and the shape of particles changed from rhombs to hexagons. In particular, monodisperse hexagonal boehmite nanoplates with an average lateral size of 58 nm and a thickness of 12.5 nm were obtained at a hydrothermal temperature of 220 °C. The selectivity of crystal growth direction was speculated as the possible formation mechanism of these as-prepared aluminium hydroxide nanoparticles. Besides, two values of 19.6 wt% and 14.64 wt% were separately measured for the weight loss of pseudo-boehmite and boehmite nanoparticles after a continuous heating, indicating their potential flame-resistant applications in the fabrication of plastic electronics and optical devices with high transparency.
Distribution and size of mucous glands in the ferret tracheobronchial tree.
Hajighasemi-Ossareh, Mohammad; Borthwell, Rachel M; Lachowicz-Scroggins, Marrah; Stevens, Jeremy E; Finkbeiner, Walter E; Widdicombe, Jonathan H
2013-11-01
A transgenic ferret model of cystic fibrosis has recently been generated. It is probable that malfunction of airway mucous glands contributes significantly to the airway pathology of this disease. The usefulness of the ferret model may therefore depend in part on how closely the airway glands of ferrets resemble those of humans. Here, we show that in the ferret trachea glands are commonest in its most ventral aspect and disappear about half way up the lateral walls; they are virtually absent from the dorsal membranous portion. Further, the aggregate volume of glands per unit mucosal surface declines progressively by about 60% between the larynx and the carina. The average frequency of glands openings for the ferret trachea as a whole is only about one-fifth that in humans (where gland openings are found at approximately the same frequency throughout the trachea). Glands in the ferret trachea are on average about one-third the size of those in the human. Therefore, the aggregate volume of tracheal glands (per unit mucosal surface area) in the ferret is only about 6% that in humans. As in other mammalian species, airway glands in the ferret disappear at an airway internal diameter of ∼1 mm, corresponding approximately in this species to airway generation 6. Copyright © 2013 Wiley Periodicals, Inc.
Ott, Florian; Pohl, Ladina; Halfmann, Marc; Hardiess, Gregor; Mallot, Hanspeter A
2016-07-01
When estimating ego-motion in environments (e.g., tunnels, streets) with varying depth, human subjects confuse ego-acceleration with environment narrowing and ego-deceleration with environment widening. Festl, Recktenwald, Yuan, and Mallot (2012) demonstrated that in nonstereoscopic viewing conditions, this happens despite the fact that retinal measurements of acceleration rate-a variable related to tau-dot-should allow veridical perception. Here we address the question of whether additional depth cues (specifically binocular stereo, object occlusion, or constant average object size) help break the confusion between narrowing and acceleration. Using a forced-choice paradigm, the confusion is shown to persist even if unambiguous stereo information is provided. The confusion can also be demonstrated in an adjustment task in which subjects were asked to keep a constant speed in a tunnel with varying diameter: Subjects increased speed in widening sections and decreased speed in narrowing sections even though stereoscopic depth information was provided. If object-based depth information (stereo, occlusion, constant average object size) is added, the confusion between narrowing and acceleration still remains but may be slightly reduced. All experiments are consistent with a simple matched filter algorithm for ego-motion detection, neglecting both parallactic and stereoscopic depth information, but leave open the possibility of cue combination at a later stage.
Synthesis of transparent dispersions of aluminium hydroxide nanoparticles.
Chen, Bo; Wang, Jie-Xin; Wang, Dan; Zeng, Xiao-Fei; Clarke, Stuart M; Chen, Jian-Feng
2018-07-27
Transparent dispersions of inorganic nanoparticles are attractive materials in many fields. However, a facile method for preparing such dispersions of aluminium hydroxide nanoparticles is yet to be realized. Here, we report a direct reactive method to prepare transparent dispersions of pseudo-boehmite nanoparticles (1 wt%) without any surface modification, and with an average particle size of 80 nm in length and 10 nm in width, as well as excellent optical transparency over 94% in the visible range. Furthermore, transparent dispersions of boehmite nanoparticles (1.5 wt%) were also achieved after an additional hydrothermal treatment. However, the optical transparency of dispersions decreased with the rise of hydrothermal temperature and the shape of particles changed from rhombs to hexagons. In particular, monodisperse hexagonal boehmite nanoplates with an average lateral size of 58 nm and a thickness of 12.5 nm were obtained at a hydrothermal temperature of 220 °C. The selectivity of crystal growth direction was speculated as the possible formation mechanism of these as-prepared aluminium hydroxide nanoparticles. Besides, two values of 19.6 wt% and 14.64 wt% were separately measured for the weight loss of pseudo-boehmite and boehmite nanoparticles after a continuous heating, indicating their potential flame-resistant applications in the fabrication of plastic electronics and optical devices with high transparency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ricciardelli, Elena; Tamone, Amelie; Cava, Antonio
We explore the morphology of galaxies living in the proximity of cosmic voids, using a sample of voids identified in the Sloan Digital Sky Survey Data Release 7. At all stellar masses, void galaxies exhibit morphologies of a later type than galaxies in a control sample, which represent galaxies in an average density environment. We interpret this trend as a pure environmental effect, independent of the mass bias, due to a slower galaxy build-up in the rarefied regions of voids. We confirm previous findings about a clear segregation in galaxy morphology, with galaxies of a later type being found atmore » smaller void-centric distances with respect to the early-type galaxies. We also show, for the first time, that the radius of the void has an impact on the evolutionary history of the galaxies that live within it or in its surroundings. In fact, an enhanced fraction of late-type galaxies is found in the proximity of voids larger than the median void radius. Likewise, an excess of early-type galaxies is observed within or around voids of a smaller size. A significant difference in galaxy properties in voids of different sizes is observed up to 2 R {sub void}, which we define as the region of influence of voids. The significance of this difference is greater than 3 σ for all the volume-complete samples considered here. The fraction of star-forming galaxies shows the same behavior as the late-type galaxies, but no significant difference in stellar mass is observed in the proximity of voids of different sizes.« less
Kremen, William S; Prom-Wormley, Elizabeth; Panizzon, Matthew S; Eyler, Lisa T; Fischl, Bruce; Neale, Michael C; Franz, Carol E; Lyons, Michael J; Pacheco, Jennifer; Perry, Michele E; Stevens, Allison; Schmitt, J Eric; Grant, Michael D; Seidman, Larry J; Thermenos, Heidi W; Tsuang, Ming T; Eisen, Seth A; Dale, Anders M; Fennema-Notestine, Christine
2010-01-15
The impact of genetic and environmental factors on human brain structure is of great importance for understanding normative cognitive and brain aging as well as neuropsychiatric disorders. However, most studies of genetic and environmental influences on human brain structure have either focused on global measures or have had samples that were too small for reliable estimates. Using the classical twin design, we assessed genetic, shared environmental, and individual-specific environmental influences on individual differences in the size of 96 brain regions of interest (ROIs). Participants were 474 middle-aged male twins (202 pairs; 70 unpaired) in the Vietnam Era Twin Study of Aging (VETSA). They were 51-59 years old, and were similar to U.S. men in their age range in terms of sociodemographic and health characteristics. We measured thickness of cortical ROIs and volume of other ROIs. On average, genetic influences accounted for approximately 70% of the variance in the volume of global, subcortical, and ventricular ROIs and approximately 45% of the variance in the thickness of cortical ROIs. There was greater variability in the heritability of cortical ROIs (0.00-0.75) as compared with subcortical and ventricular ROIs (0.48-0.85). The results did not indicate lateralized heritability differences or greater genetic influences on the size of regions underlying higher cognitive functions. The findings provide key information for imaging genetic studies and other studies of brain phenotypes and endophenotypes. Longitudinal analysis will be needed to determine whether the degree of genetic and environmental influences changes for different ROIs from midlife to later life.
Morphological Segregation in the Surroundings of Cosmic Voids
NASA Astrophysics Data System (ADS)
Ricciardelli, Elena; Cava, Antonio; Varela, Jesus; Tamone, Amelie
2017-09-01
We explore the morphology of galaxies living in the proximity of cosmic voids, using a sample of voids identified in the Sloan Digital Sky Survey Data Release 7. At all stellar masses, void galaxies exhibit morphologies of a later type than galaxies in a control sample, which represent galaxies in an average density environment. We interpret this trend as a pure environmental effect, independent of the mass bias, due to a slower galaxy build-up in the rarefied regions of voids. We confirm previous findings about a clear segregation in galaxy morphology, with galaxies of a later type being found at smaller void-centric distances with respect to the early-type galaxies. We also show, for the first time, that the radius of the void has an impact on the evolutionary history of the galaxies that live within it or in its surroundings. In fact, an enhanced fraction of late-type galaxies is found in the proximity of voids larger than the median void radius. Likewise, an excess of early-type galaxies is observed within or around voids of a smaller size. A significant difference in galaxy properties in voids of different sizes is observed up to 2 R void, which we define as the region of influence of voids. The significance of this difference is greater than 3σ for all the volume-complete samples considered here. The fraction of star-forming galaxies shows the same behavior as the late-type galaxies, but no significant difference in stellar mass is observed in the proximity of voids of different sizes.
James, Evan W; LaPrade, Christopher M; Ellman, Michael B; Wijdicks, Coen A; Engebretsen, Lars; LaPrade, Robert F
2014-11-01
Anatomic root placement is necessary to restore native meniscal function during meniscal root repair. Radiographic guidelines for anatomic root placement are essential to improve the accuracy and consistency of anatomic root repair and to optimize outcomes after surgery. To define quantitative radiographic guidelines for identification of the anterior and posterior root attachments of the medial and lateral menisci on anteroposterior (AP) and lateral radiographic views. Descriptive laboratory study. The anterior and posterior roots of the medial and lateral menisci were identified in 12 human cadaveric specimens (average age, 51.3 years; age range, 39-65 years) and labeled using 2-mm radiopaque spheres. True AP and lateral radiographs were obtained, and 2 raters independently measured blinded radiographs in relation to pertinent landmarks and radiographic reference lines. On AP radiographs, the anteromedial and posteromedial roots were, on average, 31.9 ± 5.0 mm and 36.3 ± 3.5 mm lateral to the edge of the medial tibial plateau, respectively. The anterolateral and posterolateral roots were, on average, 37.9 ± 5.2 mm and 39.3 ± 3.8 mm medial to the edge of the lateral tibial plateau, respectively. On lateral radiographs, the anteromedial and anterolateral roots were, on average, 4.8 ± 3.7 mm and 20.5 ± 4.3 mm posterior to the anterior margin of the tibial plateau, respectively. The posteromedial and posterolateral roots were, on average, 18.0 ± 2.8 mm and 19.8 ± 3.5 mm anterior to the posterior margin of the tibial plateau, respectively. The intrarater and interrater intraclass correlation coefficients (ICCs) were >0.958, demonstrating excellent reliability. The meniscal root attachment sites were quantitatively and reproducibly defined with respect to anatomic landmarks and superimposed radiographic reference lines. The high ICCs indicate that the measured radiographic relationships are a consistent means for evaluating meniscal root positions. This study demonstrated consistent and reproducible radiographic guidelines for the location of the meniscal roots. These measurements may be used to assess root positions on intraoperative fluoroscopy and postoperative radiographs. © 2014 The Author(s).
A real-world size organization of object responses in occipito-temporal cortex
Konkle, Talia; Oliva, Aude
2012-01-01
SUMMARY While there are selective regions of occipito-temporal cortex that respond to faces, letters, and bodies, the large-scale neural organization of most object categories remains unknown. Here we find that object representations can be differentiated along the ventral temporal cortex by their real-world size. In a functional neuroimaging experiment, observers were shown pictures of big and small real-world objects (e.g. table, bathtub; paperclip, cup), presented at the same retinal size. We observed a consistent medial-to-lateral organization of big and small object preferences in the ventral temporal cortex, mirrored along the lateral surface. Regions in the lateral-occipital, infero-temporal, and parahippocampal cortices showed strong peaks of differential real-world size selectivity, and maintained these preferences over changes in retinal size and in mental imagery. These data demonstrate that the real-world size of objects can provide insight into the spatial topography of object representation. PMID:22726840
Estimating the Size and Timing of Maximum Amplitude for Cycle 23 from Its Early Cycle Behavior
NASA Technical Reports Server (NTRS)
Wilson, Robert M.; Hathaway, David H.; Reichmann, Edwin J.
1998-01-01
On the basis of the lowest observed smoothed monthly mean sunspot number, cycle 23 appears to have conventionally begun in May 1996, in conjunction with the first appearance of a new cycle, high-latitude spot-group. Such behavior, however, is considered rather unusual, since, previously (based upon the data- available cycles 12-22), the first appearance of a new cycle, high-latitude spot- group has always preceded conventional onset by at least 3 months. Furthermore, accepting May 1996 as the official start for cycle 23 poses a dilemma regarding its projected size and timing of maximum amplitude. Specifically, from the max-min and amplitude-period relationships we infer that cycle 23 should be above average in size and a fast riser, with maximum amplitude occurring before May 2000 (being in agreement with projections for cycle 23 based on precursor information), yet from its initial languid rate of rise (during the first 6 months of the cycle) we infer that it should be below average in size and a slow riser, with maximum amplitude occurring after May 2000. The dilemma vanishes, however, when we use a slightly later-occurring onset. For example, using August 1996, a date associated with a local secondary minimum prior to the rapid rise that began shortly thereafter (in early 1997), we infer that cycle 23's rate of rise is above that for the mean of cycles 1-22, the mean of cycles 10-22 (the modern era cycles), the mean of the modern era'fast risers,' and the largest of the modern era 'slow risers' (i.e., cycle 20), thereby, suggesting that cycle 23 will be both fast-rising and above average in size, peaking before August 2000. Additionally, presuming cycle 23 to be a well- behaved fast-rising cycle (regardless of whichever onset date is used), we also infer that its maximum amplitude likely will measure about 144.0 q+/- 28.8 (from the general behavior found for the bulk of modern era fast risers; i.e., 5 of 7 have had their maximum amplitude to lie within 20% of the mean curve for modern era fast risers). It is apparent, then, that sunspot number growth during 1998 will prove crucial for correctly establishing the size and shape of cycle 23.
Graphene saturable absorber mirror for ultra-fast-pulse solid-state laser.
Xu, Jin-Long; Li, Xian-Lei; Wu, Yong-Zhong; Hao, Xiao-Peng; He, Jing-Liang; Yang, Ke-Jian
2011-05-15
High-quality graphene sheets with lateral size over 20 μm have been obtained by bath sonicating after subjecting the wormlike graphite marginally to mixed oxidizer. To date, to our knowledge, they are the largest graphene sheets prepared by exfoliation in the liquid phase. A saturable absorber mirror was fabricated based on these sheets. We exploited it to realize mode-locking operation in a diode-pumped Nd:GdVO(4) laser. A pulse duration of 16 ps was produced with an average power of 360 mW and a highest pulse energy of 8.4 nJ for a graphene mode-locked laser. © 2011 Optical Society of America
Surface-potential undulation of Alq3 thin films prepared on ITO, Au, and n-Si.
Ozasa, Kazunari; Ito, Hiromi; Maeda, Mizuo; Hara, Masahiko
2012-01-01
The surface potential (SP) morphology on thin films of tris(8-hydroxyquinolinato) aluminum (Alq3) was investigated with Kelvin probe force microscopy. Thin Alq3 films of 100 nm were prepared on ITO/glass substrates, Au/mica substrates, and n-Si substrates. Cloud-like morphologies of the SP undulation with 200-400 nm in lateral size were observed for all three types of the substrates. New larger peaks were observed in the cloud-like morphologies when the surfaces were exposed shortly to a light, while the SP average was reduced monotonically. The nonuniform distribution of charged traps and mobility was deduced from the SP undulation morphology and its photoexposure dependences.
Fukuda, T
1992-01-01
A study was made on the capability to receive character information and the factors restricting it. The study showed that the capability indicated by the memory span was limited by the average number of characters for words that are made up of individual characters, and calculated in terms of information quantity, there was no difference among the individual characters. The differences in memory span, depending on the size of the pattern presented, was negligible. The difference in the way characters were arranged produced the difference in memory span saturation. This phenomenon is explained by the nature of the lateral interference effect working among the adjacent characters.
Physical therapy treatments for low back pain in children and adolescents: a meta-analysis
2013-01-01
Background Low back pain (LBP) in adolescents is associated with LBP in later years. In recent years treatments have been administered to adolescents for LBP, but it is not known which physical therapy treatment is the most efficacious. By means of a meta-analysis, the current study investigated the effectiveness of the physical therapy treatments for LBP in children and adolescents. Methods Studies in English, Spanish, French, Italian and Portuguese, and carried out by March 2011, were selected by electronic and manual search. Two independent researchers coded the moderator variables of the studies, and performed the effect size calculations. The mean effect size index used was the standardized mean change between the pretest and posttest, and it was applied separately for each combination of outcome measures, (pain, disability, flexibility, endurance and mental health) and measurement type (self-reports, and clinician assessments). Results Eight articles that met the selection criteria enabled us to define 11 treatment groups and 5 control groups using the group as the unit of analysis. The 16 groups involved a total sample of 334 subjects at the posttest (221 in the treatment groups and 113 in the control groups). For all outcome measures, the average effect size of the treatment groups was statistically and clinically significant, whereas the control groups had negative average effect sizes that were not statistically significant. Conclusions Of all the physical therapy treatments for LBP in children and adolescents, the combination of therapeutic physical conditioning and manual therapy is the most effective. The low number of studies and control groups, and the methodological limitations in this meta-analysis prevent us from drawing definitive conclusions in relation to the efficacy of physical therapy treatments in LBP. PMID:23374375
Physical therapy treatments for low back pain in children and adolescents: a meta-analysis.
Calvo-Muñoz, Inmaculada; Gómez-Conesa, Antonia; Sánchez-Meca, Julio
2013-02-02
Low back pain (LBP) in adolescents is associated with LBP in later years. In recent years treatments have been administered to adolescents for LBP, but it is not known which physical therapy treatment is the most efficacious. By means of a meta-analysis, the current study investigated the effectiveness of the physical therapy treatments for LBP in children and adolescents. Studies in English, Spanish, French, Italian and Portuguese, and carried out by March 2011, were selected by electronic and manual search. Two independent researchers coded the moderator variables of the studies, and performed the effect size calculations. The mean effect size index used was the standardized mean change between the pretest and posttest, and it was applied separately for each combination of outcome measures, (pain, disability, flexibility, endurance and mental health) and measurement type (self-reports, and clinician assessments). Eight articles that met the selection criteria enabled us to define 11 treatment groups and 5 control groups using the group as the unit of analysis. The 16 groups involved a total sample of 334 subjects at the posttest (221 in the treatment groups and 113 in the control groups). For all outcome measures, the average effect size of the treatment groups was statistically and clinically significant, whereas the control groups had negative average effect sizes that were not statistically significant. Of all the physical therapy treatments for LBP in children and adolescents, the combination of therapeutic physical conditioning and manual therapy is the most effective. The low number of studies and control groups, and the methodological limitations in this meta-analysis prevent us from drawing definitive conclusions in relation to the efficacy of physical therapy treatments in LBP.
Energy balance, early life body size, and plasma prolactin levels in postmenopausal women
Su, Xuefen; Hankinson, Susan E.; Clevenger, Charles V.; Eliassen, A. Heather; Tworoger, Shelley S.
2009-01-01
Objective We examined the relationships of prolactin with birth weight; childhood, adolescent and adult body size measures; adult physical activity and inactivity; and alcohol consumption among 1,423 postmenopausal women from the Nurses’ Health Study. Methods Information on exposures was collected on biennial questionnaires beginning in 1976. Blood was collected from 32,826 participants in 1990; prolactin was measured in a subset of women who were controls for a nested breast cancer case-control study. Generalized linear models were adjusted for assay batch, medication use at blood draw, and other potential predictors of prolactin. Results No associations were observed for adult factors (p-trend≥0.17), body mass index at age 18, birth weight, or height (p-trend≥0.27). There was an inverse association between body size at ages 5 (p-trend=0.03) and 10 (p-trend=0.05) and prolactin, with levels 9% lower among women with the heaviest versus leanest average childhood body size. This association was more pronounced among women with a birth weight <7 pounds (p-trend=0.004; p-interaction between birth weight and childhood body size=0.01). Conclusions Our results suggest that few adult lifestyle risk factors are associated with prolactin levels in postmenopausal women; however, childhood body size may be a predictor of levels later in life. PMID:18853263
77 FR 72766 - Small Business Size Standards: Support Activities for Mining
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-06
... its entirety for parties who have an interest in SBA's overall approach to establishing, evaluating....gov , Docket ID: SBA-2009- 0008. SBA continues to welcome comments on its methodology from interested.... Average firm size. SBA computes two measures of average firm size: simple average and weighted average...
Maulfair, D D; Fustini, M; Heinrichs, A J
2011-07-01
The objective of this experiment was to evaluate the effects of feeding rations of different particle sizes on rumen digesta and fecal matter particle size. Four rumen-cannulated, multiparous, Holstein cows (104±15 d in milk) were randomly assigned to treatments in a 4×4 Latin square design. The diets consisted of 29.4% corn silage, 22.9% ground corn, 17.6% alfalfa haylage, and 11.8% dry grass hay [20% of forage dry matter (DM)] on a DM basis. Dry grass hay was chopped to 4 different lengths to vary the total mixed ration (TMR) particle size. Geometric mean particle sizes of the rations were 4.46, 5.10, 5.32, and 5.84 mm for short, medium, long, and extra long diets, respectively. The ration affected rumen digesta particle size for particles ≥3.35 mm, and had no effect on distribution of particles <3.35 mm. All rumen digesta particle size fractions varied by time after feeding, with soluble particle fractions increasing immediately after feeding and 0.15, 0.6, and 1.18-mm particle size fractions decreasing slightly after feeding. Particle fractions >1.18 mm had ration by time interactions. Fecal neutral detergent fiber (NDF) and indigestible NDF concentrations decreased with increasing TMR particle size. Fecal particle size expressed as total geometric mean particle length followed this same tendency. Fecal particle size, expressed as retained geometric mean particle length, averaged 1.13 mm with more than 36% of particles being larger than 1.18 mm. All fecal nutrient concentrations measured were significantly affected by time after feeding, with NDF and indigestible NDF increasing after feeding and peaking at about 12h later and then decreasing to preprandial levels. Starch concentrations were determined to have the opposite effect. Additionally, apparent digestibility of diet nutrients was analyzed and DM digestibility tended to decrease with increasing TMR particle size, whereas other nutrient digestibilities were not different among rations. These results show that the critical size for increased resistance to rumen escape is larger than 1.18 mm and this critical size is constant throughout the day. This study also concludes that, when using average quality grass hay to provide the range of particle sizes fed, DM digestibility tends to decrease with increasing ration particle size. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Hallux valgus correction using transarticular lateral release with distal chevron osteotomy.
Choi, Young Rak; Lee, Ho Seong; Jeong, Jae Jung; Kim, Sang Woo; Jeon, In-Ho; Lee, Dong Ho; Lee, Woo Chun
2012-10-01
Transarticular lateral release through a medial incision can avoid a dorsal incision. This study investigated outcomes following hallux valgus correction using transarticular lateral release, distal chevron metatarsal osteotomy and Akin phalangeal osteotomy through one medial incision. Between June 2004 and May 2009, a single surgeon performed a transarticular lateral release, distal chevron metatarsal osteotomy and Akin phalangeal osteotomy through one medial incision for hallux valgus on a total of 103 feet of 68 patients. The average patient age at the time of surgery was 51 years, and the average followup was 27 months. The average preoperative and final followup results were: 1) hallux valgus angle improvement from 29 degrees to 5 degrees, 2) intermetatarsal angle from 13 degrees to 5 degrees and 3) medial sesamoid bone position from 3 to 1 (p < 0.05 for each variable). The average AOFAS scores were improved from 49 to 92, and the VAS pain scores were improved from 7 to 1 (p < 0.05 for both variables). No patient had a serious complication such as infection, avascular necrosis, nonunion, transfer-metatarsalgia, or first metatarsophalangeal joint arthritis. Hallux valgus correction using transarticular lateral release, distal chevron metatarsal osteotomy and Akin phalangeal osteotomy through one medial incision was found to be effective and safe. The advantages include that the procedure is simple, early ambulation is possible, and there is no dorsal scarring.
Waif goodbye! Average-size female models promote positive body image and appeal to consumers.
Diedrichs, Phillippa C; Lee, Christina
2011-10-01
Despite consensus that exposure to media images of thin fashion models is associated with poor body image and disordered eating behaviours, few attempts have been made to enact change in the media. This study sought to investigate an effective alternative to current media imagery, by exploring the advertising effectiveness of average-size female fashion models, and their impact on the body image of both women and men. A sample of 171 women and 120 men were assigned to one of three advertisement conditions: no models, thin models and average-size models. Women and men rated average-size models as equally effective in advertisements as thin and no models. For women with average and high levels of internalisation of cultural beauty ideals, exposure to average-size female models was associated with a significantly more positive body image state in comparison to exposure to thin models and no models. For men reporting high levels of internalisation, exposure to average-size models was also associated with a more positive body image state in comparison to viewing thin models. These findings suggest that average-size female models can promote positive body image and appeal to consumers.
Sahraei, Nasim; Forberich, Karen; Venkataraj, Selvaraj; Aberle, Armin G; Peters, Marius
2014-01-13
Light scattering at randomly textured interfaces is essential to improve the absorption of thin-film silicon solar cells. Aluminium-induced texture (AIT) glass provides suitable scattering for amorphous silicon (a-Si:H) solar cells. The scattering properties of textured surfaces are usually characterised by two properties: the angularly resolved intensity distribution and the haze. However, we find that the commonly used haze equations cannot accurately describe the experimentally observed spectral dependence of the haze of AIT glass. This is particularly the case for surface morphologies with a large rms roughness and small lateral feature sizes. In this paper we present an improved method for haze calculation, based on the power spectral density (PSD) function of the randomly textured surface. To better reproduce the measured haze characteristics, we suggest two improvements: i) inclusion of the average lateral feature size of the textured surface into the haze calculation, and ii) considering the opening angle of the haze measurement. We show that with these two improvements an accurate prediction of the haze of AIT glass is possible. Furthermore, we use the new equation to define optimum morphology parameters for AIT glass to be used for a-Si:H solar cell applications. The autocorrelation length is identified as the critical parameter. For the investigated a-Si:H solar cells, the optimum autocorrelation length is shown to be 320 nm.
NASA Astrophysics Data System (ADS)
Waki, Hiroyuki; Kitamura, Takeshi; Kobayashi, Akira
2009-12-01
The mechanical properties of a MCrAlY coating significantly influence the initiation of cracks in the superalloy substrate under thermomechanical-fatigue conditions. Previous studies have developed a convenient method for evaluating the mechanical properties of sprayed coatings by lateral compression of a circular tube coating. This method does not need chucking, and manufacturing the free-standing coating is quite straightforward. In this study, the mechanical properties of the free-standing CoNiCrAlY coatings prepared using low-pressure plasma spraying (LPPS), high-velocity oxyfuel (HVOF) spraying, and atmospheric plasma spraying (APS) were systematically measured with the lateral compression method at room temperature through to 920 °C. The effect of postspray thermal treatments, in vacuum and in air, on the mechanical properties was investigated in the 400 to 1100 °C temperature range. It was found that high-temperature thermal treatment in air was effective in increasing the bending strength and Young’s modulus. It was especially effective on the APS coatings, which were produced using powders with average size 60 μm, and on HVOF coating, whose bending strengths increased by approximately three times. On the contrary, the enhancement in the LPPS and APS coatings produced with powders 21 μm in size was found to be approximately 1.6 times.
McCormick, Stephen D.; Haro, Alexander; Lerner, Darren T.; O'Dea, Michael F.; Regish, Amy M.
2014-01-01
The timing of downstream migration and detection rates of hatchery-reared Atlantic salmon Salmo salar smolts and stream-reared smolts (stocked 2 years earlier as fry) were examined in the Connecticut River (U.S.A.) using passive integrated transponder (PIT) tags implanted into fish and then detected at a downstream fish bypass collection facility at Turners Falls, MA (river length 192 km). In two successive years, hatchery-reared smolts were released in mid-April and early May at two sites: the West River (river length 241 km) or the Passumpsic (river length 450 km). Hatchery-reared smolts released higher in the catchment arrived 7 to 14 days later and had significantly lower detection rates than smolts stocked lower in the catchment. Hatchery-reared smolts released 3 weeks apart at the same location were detected downstream at similar times, indicating that early-release smolts had a lower average speed after release and longer residence time. The size and gill Na+/K+-ATPase (NKA) activity of smolts at the time of release were significantly greater for detected fish (those that survived and migrated) than for those that were not detected. Stream-reared pre-smolts (>11·5 cm) from four tributaries (length 261–551 km) were tagged in autumn and detected during smolt migration the following spring. Stream-reared smolts higher in the catchment arrived later and had significantly lower detection rates. The results indicate that both hatchery and stream-reared smolts from the upper catchment will arrive at the mouth of the river later and experience higher overall mortality than fish from lower reaches, and that both size and gill NKA activity are related to survival during downstream migration.
Rabbit hepatic arterial anatomy variations: implications on experimental design.
Tam, Alda L; Melancon, Marites P; Ensor, Joe; Liu, Yang; Dixon, Katherine; McWatters, Amanda; Gupta, Sanjay
2014-12-01
The VX2 rabbit model of liver cancer is commonly used to evaluate the efficacy of locoregional anticancer therapy and knowledge of the hepatic arterial anatomy in the rabbit is important for catheter-directed experiments. To describe the normal anatomy and anatomic variations of the celiac axis and hepatic artery in the rabbit. Angiograms of 222 rabbits were retrospectively reviewed. The branching pattern of the celiac axis was classified and the diameters of the major branches were measured. Paired t-tests were used to compare the difference between the average sizes of arteries. Variant celiac axis or hepatic artery anatomy was noted in 25.9% of angiograms, with the gastric branches arising from the proper hepatic artery in 23.3% of cases. The celiac axis could be successfully classified into one of five distinct branching patterns in 193 (86.9%) cases. The mean diameters of the right and left hepatic arteries were 0.67 mm (95% CI [0.64, 0.7]) and 1.25 mm (95% CI [1.19, 1.31]), respectively. The mean diameters of the medial and lateral branches of the left hepatic artery were 0.63 mm (95% CI [0.6, 0.67]) and 0.91 mm (95% CI [0.86, 0.96]), respectively. The right hepatic artery was significantly smaller than the left hepatic artery and the lateral branch of the left hepatic artery (all P values <0.0001). Arterial variants in the rabbit are not uncommon. The proper hepatic artery often gives origin to gastric artery branches. To facilitate superselective intra-arterial intervention, the left lateral lobe of the liver should be targeted for tumor implantation because of the significant size difference between the right and left hepatic arteries. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Jia, Yongwei; Cheng, Liming; Yu, Guangrong; Lou, Yongjian; Yu, Yan; Chen, Bo; Ding, Zuquan
2008-03-01
A method of digital image measurement of specimen deformation based on CCD cameras and Image J software was developed. This method was used to measure the biomechanics behavior of human pelvis. Six cadaveric specimens from the third lumbar vertebra to the proximal 1/3 part of femur were tested. The specimens without any structural abnormalities were dissected of all soft tissue, sparing the hip joint capsules and the ligaments of the pelvic ring and floor. Markers with black dot on white background were affixed to the key regions of the pelvis. Axial loading from the proximal lumbar was applied by MTS in the gradient of 0N to 500N, which simulated the double feet standing stance. The anterior and lateral images of the specimen were obtained through two CCD cameras. Based on Image J software, digital image processing software, which can be freely downloaded from the National Institutes of Health, digital 8-bit images were processed. The procedure includes the recognition of digital marker, image invert, sub-pixel reconstruction, image segmentation, center of mass algorithm based on weighted average of pixel gray values. Vertical displacements of S1 (the first sacral vertebrae) in front view and micro-angular rotation of sacroiliac joint in lateral view were calculated according to the marker movement. The results of digital image measurement showed as following: marker image correlation before and after deformation was excellent. The average correlation coefficient was about 0.983. According to the 768 × 576 pixels image (pixel size 0.68mm × 0.68mm), the precision of the displacement detected in our experiment was about 0.018 pixels and the comparatively error could achieve 1.11\\perthou. The average vertical displacement of S1 of the pelvis was 0.8356+/-0.2830mm under vertical load of 500 Newtons and the average micro-angular rotation of sacroiliac joint in lateral view was 0.584+/-0.221°. The load-displacement curves obtained from our optical measure system matched the clinical results. Digital image measurement of specimen deformation based on CCD cameras and Image J software has good perspective for application in biomechanical research, which has the advantage of simple optical setup, no-contact, high precision, and no special requirement of test environment.
Perception of the average size of multiple objects in chimpanzees (Pan troglodytes).
Imura, Tomoko; Kawakami, Fumito; Shirai, Nobu; Tomonaga, Masaki
2017-08-30
Humans can extract statistical information, such as the average size of a group of objects or the general emotion of faces in a crowd without paying attention to any individual object or face. To determine whether summary perception is unique to humans, we investigated the evolutional origins of this ability by assessing whether chimpanzees, which are closely related to humans, can also determine the average size of multiple visual objects. Five chimpanzees and 18 humans were able to choose the array in which the average size was larger, when presented with a pair of arrays, each containing 12 circles of different or the same sizes. Furthermore, both species were more accurate in judging the average size of arrays consisting of 12 circles of different or the same sizes than they were in judging the average size of arrays consisting of a single circle. Our findings could not be explained by the use of a strategy in which the chimpanzee detected the largest or smallest circle among those in the array. Our study provides the first evidence that chimpanzees can perceive the average size of multiple visual objects. This indicates that the ability to compute the statistical properties of a complex visual scene is not unique to humans, but is shared between both species. © 2017 The Authors.
Perception of the average size of multiple objects in chimpanzees (Pan troglodytes)
Kawakami, Fumito; Shirai, Nobu; Tomonaga, Masaki
2017-01-01
Humans can extract statistical information, such as the average size of a group of objects or the general emotion of faces in a crowd without paying attention to any individual object or face. To determine whether summary perception is unique to humans, we investigated the evolutional origins of this ability by assessing whether chimpanzees, which are closely related to humans, can also determine the average size of multiple visual objects. Five chimpanzees and 18 humans were able to choose the array in which the average size was larger, when presented with a pair of arrays, each containing 12 circles of different or the same sizes. Furthermore, both species were more accurate in judging the average size of arrays consisting of 12 circles of different or the same sizes than they were in judging the average size of arrays consisting of a single circle. Our findings could not be explained by the use of a strategy in which the chimpanzee detected the largest or smallest circle among those in the array. Our study provides the first evidence that chimpanzees can perceive the average size of multiple visual objects. This indicates that the ability to compute the statistical properties of a complex visual scene is not unique to humans, but is shared between both species. PMID:28835550
Diedrichs, Phillippa C; Lee, Christina
2010-06-01
Increasing body size and shape diversity in media imagery may promote positive body image. While research has largely focused on female models and women's body image, men may also be affected by unrealistic images. We examined the impact of average-size and muscular male fashion models on men's and women's body image and perceived advertisement effectiveness. A sample of 330 men and 289 women viewed one of four advertisement conditions: no models, muscular, average-slim or average-large models. Men and women rated average-size models as equally effective in advertisements as muscular models. For men, exposure to average-size models was associated with more positive body image in comparison to viewing no models, but no difference was found in comparison to muscular models. Similar results were found for women. Internalisation of beauty ideals did not moderate these effects. These findings suggest that average-size male models can promote positive body image and appeal to consumers. 2010 Elsevier Ltd. All rights reserved.
Roth, Bradley J.
2002-09-01
Insidious experimental artifacts and invalid theoretical assumptions complicate the comparison of numerical predictions and observed data. Such difficulties are particularly troublesome when studying electrical stimulation of the heart. During unipolar stimulation of cardiac tissue, the artifacts include nonlinearity of membrane dyes, optical signals blocked by the stimulating electrode, averaging of optical signals with depth, lateral averaging of optical signals, limitations of the current source, and the use of excitation-contraction uncouplers. The assumptions involve electroporation, membrane models, electrode size, the perfusing bath, incorrect model parameters, the applicability of a continuum model, and tissue damage. Comparisons of theory and experiment during far-field stimulation are limited by many of these same factors, plus artifacts from plunge and epicardial recording electrodes and assumptions about the fiber angle at an insulating boundary. These pitfalls must be overcome in order to understand quantitatively how the heart responds to an electrical stimulus. (c) 2002 American Institute of Physics.
Michael, Claire W; Naik, Kalyani; McVicker, Michael
2013-05-01
We developed a value stream map (VSM) of the Papanicolaou test procedure to identify opportunities to reduce waste and errors, created a new VSM, and implemented a new process emphasizing Lean tools. Preimplementation data revealed the following: (1) processing time (PT) for 1,140 samples averaged 54 hours; (2) 27 accessioning errors were detected on review of 357 random requisitions (7.6%); (3) 5 of the 20,060 tests had labeling errors that had gone undetected in the processing stage. Four were detected later during specimen processing but 1 reached the reporting stage. Postimplementation data were as follows: (1) PT for 1,355 samples averaged 31 hours; (2) 17 accessioning errors were detected on review of 385 random requisitions (4.4%); and (3) no labeling errors were undetected. Our results demonstrate that implementation of Lean methods, such as first-in first-out processes and minimizing batch size by staff actively participating in the improvement process, allows for higher quality, greater patient safety, and improved efficiency.
Lee, Chang-Rack; Bin, Seong-Il; Kim, Jong-Min; Kim, Nam-Ki
2016-11-01
To evaluate the change in the thickness and width of the residual meniscus using magnetic resonance imaging (MRI) in patients who underwent arthroscopic partial meniscectomy for discoid lateral meniscus (DLM), to assess whether the degeneration of the articular cartilage in the lateral compartment of the knee progressed, and to evaluate clinical results. Among the patients who underwent arthroscopic partial meniscectomy for DLM between January 1997 and December 2011, those who were aged 40 or below at surgery were followed up for at least 3 years, and received at least 2 follow-up MRIs that were retrospectively reviewed. MRIs were done in symptomatic knees. Using MRI, the relative thickness and width were measured in the anterior horn, midportion, and posterior horn. To determine whether the degeneration of the lateral compartment would progress, the articular cartilage was graded based on the Outerbridge classification in MRIs. The clinical results were evaluated using the Lysholm score. A total of 20 patients (21 knees) were included. The average follow-up period was 6.8 years. In residual meniscus, the relative thickness of the midportion decreased from 9.0% ± 2.4% to 7.3% ± 2.3% (P < .001), the relative thickness of the anterior horn decreased from 15.6% ± 4.3% to 14.3% ± 6.7% (P = .030), and the relative thickness of the posterior horn decreased from 20.0% ± 4.4% to 16.7% ± 6.7% (P = .019). A decrease in the relative width was observed in the midportion (12.4% ± 4.8% to 10.9% ± 4.9%, P = .003). No significant changes in size were observed in the medial meniscus. A progression of degeneration in the lateral compartment was observed. However, the clinical results did not present significant changes. In symptomatic patients after arthroscopic partial meniscectomy for DLM, the thickness and width of the residual meniscus decreases over time. The arthritic change of the lateral compartment of the knee progressed. However, the change in the size of the residual meniscus was of unknown clinical significance. Level IV, therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Providing a harmonious smile with laminate veneers for a patient with peg-shaped lateral incisors
Alberton, Simone Beatriz; Alberton, Victória; de Carvalho, Rodrigo Varella
2017-01-01
The most common discrepancy concerning tooth size is the presence of peg-shaped lateral incisors, which can cause teeth with reduced size, anterior diastema, and consequently an unpleasant smile. The development of the adhesive dentistry and ceramic veneers allowed all ceramic-bonded restorations to become an esthetic and functional approach to reestablish the smile harmony. The purpose of this clinical report is to describe a conservative treatment approach to recover an esthetic disharmony caused by bilateral peg-shaped lateral incisors. A 30-year-old female patient was seeking treatment to solve an esthetic disharmony of her smile. Lithium disilicate veneers were planned and build-up with the help of diagnostic models, wax-up, mock-up, and silicone guides, to restore the morphology, size, function, and esthetic of upper lateral incisors and smile. The lithium disilicate veneers were able to provide the harmonization of the patient's smile, recovering the teeth size, shape, and anatomic characteristics. PMID:29279628
Providing a harmonious smile with laminate veneers for a patient with peg-shaped lateral incisors.
Alberton, Simone Beatriz; Alberton, Victória; de Carvalho, Rodrigo Varella
2017-01-01
The most common discrepancy concerning tooth size is the presence of peg-shaped lateral incisors, which can cause teeth with reduced size, anterior diastema, and consequently an unpleasant smile. The development of the adhesive dentistry and ceramic veneers allowed all ceramic-bonded restorations to become an esthetic and functional approach to reestablish the smile harmony. The purpose of this clinical report is to describe a conservative treatment approach to recover an esthetic disharmony caused by bilateral peg-shaped lateral incisors. A 30-year-old female patient was seeking treatment to solve an esthetic disharmony of her smile. Lithium disilicate veneers were planned and build-up with the help of diagnostic models, wax-up, mock-up, and silicone guides, to restore the morphology, size, function, and esthetic of upper lateral incisors and smile. The lithium disilicate veneers were able to provide the harmonization of the patient's smile, recovering the teeth size, shape, and anatomic characteristics.
The Association between Penis Size and Sexual Health among Men Who Have Sex with Men
Grov, Christian; Parsons, Jeffrey T.; Bimbi, David S.
2010-01-01
Larger penis size has been equated with a symbol of power, stamina, masculinity, and social status. Yet, there has been little research among men who have sex with men assessing the association between penis size and social-sexual health. Survey data from a diverse sample of 1,065 men who have sex with men were used to explore the association between perceived penis size and a variety of psychosocial outcomes. Seven percent of men felt their penis was “below average,” 53.9% “average,” and 35.5% “above average.” Penis size was positively related to satisfaction with size and inversely related to lying about penis size (all p < .01). Size was unrelated to condom use, frequency of sex partners, HIV status, or recent diagnoses of HBV, HCV, gonorrhea/Chlamydia/urinary tract infections, and syphilis. Men with above average penises were more likely to report HPV and HSV-2 (Fisher’s exact p ≤ .05). Men with below average penises were significantly more likely to identify as “bottoms” (anal receptive) and men with above average penises were significantly more likely to identify as tops (anal insertive). Finally, men with below average penises fared significantly worse than other men on three measures of psychosocial adjustment. Though most men felt their penis size was average, many fell outside this “norm.” The disproportionate number of viral skin-to-skin STIs (HSV-2 and HPV) suggest size may play a role in condom slippage/breakage. Further, size played a significant role in sexual positioning and psychosocial adjustment. These data highlight the need to better understand the real individual-level consequences of living in a penis-centered society. PMID:19139986
Bernard, Larry C; Walsh, R Patricia
2002-10-01
The present study replicated and extended earlier research on temporal sampling effects in university subject pools. Data were obtained from 236 participants, 79 men and 157 women, in a university subject pool during a 15-wk. semester. Without knowing the purpose of the study, participants self-selected to participate earlier (Weeks 4 and 5; n = 105) or later (Weeks 14 and 15; n = 131). Three hypotheses were investigated: (1) that the personality patterns of earlier and later participants on the NEO Personality Inventory-Revised and the Personality Research Form differ significantly, with earlier participants scoring higher on the latter scales reflecting social responsibility and higher on former Conscientiousness and Neuroticism scales; (2) that there are similar significant differences between participants in the earlier and later groups compared to the male and female college normative samples for the two tests: and (3) that earlier participants will have higher actual Scholastic Assessment Test scores and Grade Point Averages. Also investigated was whether participants' foreknowledge that their actual Scholastic Assessment Test scores and Grade Point Averages would be obtained would affect their accuracy of self-report. In contrast to prior research, neither the first nor second hypothesis was supported by the current study; there do not appear to be consistent differences on personality variables. However, the third hypothesis was supported. Earlier participants had higher actual high school Grade Point Average, college Grade Point Average, and Scholastic Assessment Test Verbal scores. Foreknowledge that actual Scholastic Assessment Test scores and Grade Point Averages would be obtained did not affect the accuracy of self-report. In addition, later participants significantly over-reported their scores, and significantly more women than men and more first-year than senior-year subjects participated in the early group.
In Situ Aerosol Size Distributions and Clear Column Radiative Closure During ACE-2
NASA Technical Reports Server (NTRS)
Collins, D. R.; Johnson, H. H.; Seinfeld, J. H.; Flagan, R. C.; Gasso, S.; Hegg, D. A.; Russell, P. B.; Schmid, B.; Livingston, J. M.; Oestroem, E.;
2000-01-01
As part of the second Aerosol Characterization Experiment (ACE-2) during June and July of 1997, aerosol size distributions were measured on board the CIRPAS Pelican aircraft through the use of a DMA and two OPCS. During the campaign, the boundary layer aerosol typically possessed characteristics representative of a background marine aerosol or a continentally influenced aerosol, while the free tropospheric aerosol was characterized by the presence or absence of a Saharan dust layer. A range of radiative closure comparisons were made using the data obtained during vertical profiles flown on four missions. Of particular interest here are the comparisons made between the optical properties as determined through the use of measured aerosol size distributions and those measured directly by an airborne 14-wavelength sunphotometer and three nephelometers. Variations in the relative humidity associated with each of the direct measurements required consideration of the hygroscopic properties of the aerosol for size distribution based calculations. Simultaneous comparison with such a wide range of directly measured optical parameters not only offers evidence of the validity of the physicochemical description of the aerosol when closure is achieved, but also provides insight into potential sources of error when some or all of the comparisons result in disagreement. Agreement between the derived and directly measured optical properties varied for different measurements and for different cases. Averaged over the four case studies, the derived extinction coefficient at 525 nm exceeded that measured by the sunphotomoter by 2.5% in the clean boundary later, but underestimated measurements by 13% during pollution events. For measurements within the free troposphere, the mean derived extinction coefficient was 3.3% and 17% less than that measured by the sunphotometer during dusty and nondusty conditions, respectively. Likewise, averaged discrepancies between the derived and measured scattering coefficient were -9.6%, +4.7%, +17%, and -41% for measurements within the clean boundary layer, polluted boundary layer, free troposphere with a dust layer, and free troposphere without a dust layer, respectively. Each of these quantities, as well as the majority of the > 100 individual comparisons from which they were averaged, were within estimated uncertainties.
NASA Astrophysics Data System (ADS)
Sathiyanarayanan, Rajesh; Hamouda, Ajmi Bh.; Pimpinelli, A.; Einstein, T. L.
2011-01-01
In an accompanying article we showed that surface morphologies obtained through codeposition of a small quantity (2%) of impurities with Cu during growth (step-flow mode, θ = 40 ML) significantly depends on the lateral nearest-neighbor binding energy (ENN) to Cu adatom and the diffusion barrier (Ed) of the impurity atom on Cu(0 0 1). Based on these two energy parameters, ENN and Ed, we classify impurity atoms into four sets. We study island nucleation and growth in the presence of codeposited impurities from different sets in the submonolayer (θ⩽ 0.7 ML) regime. Similar to growth in the step-flow mode, we find different nucleation and growth behavior for impurities from different sets. We characterize these differences through variations of the number of islands (Ni) and the average island size with coverage (θ). Further, we compute the critical nucleus size (i) for all of these cases from the distribution of capture-zone areas using the generalized Wigner distribution.
Cardinal ligament surgical anatomy: cardinal points at hysterectomy.
Samaan, Andrew; Vu, Dzung; Haylen, Bernard T; Tse, Kelly
2014-02-01
The cardinal ligament (CL) still requires more precise anatomical mapping. We aim to elucidate the anatomy of the CL and the roles it plays in gynecological surgery. Studies employed sharp dissection of 28 formalin-fixed cadaveric hemipelves and 10 unembalmed cadaveric hemipelves. The CL (total length averaging 10.0 cm) can be subdivided into three sections: a distal (cervical) section, on average 2.1 cm long, attached to the lateral aspect of the cervix (posteriorly, it was confluent with the attachment of the uterosacral [USL] ligament to form the cardinal-uterosacral confluence [CUSC]); an intermediate section, on average 3.4 cm long, running laterally (slightly posteriorly) from the cervix; a proximal (pelvic) section, relatively thick, triangular-shaped on cross-section, averaging 4.6 cm long, attached to the lateral pelvic sidewall, with its apex at the first branching of the internal iliac artery. Only the distal section is free of any significant neural or vascular component (ureter is in the intermediate section) and therefore safe for surgical use. The CUSC (first pedicle of a vaginal hysterectomy and later pedicle of an abdominal hysterectomy), if attached to the vaginal vault at hysterectomy has the potential for both lateral (CL) and supero-posterior (USL) surgical support. This pedicle would not be subsequently accessible for other surgeries. Suggested cardinal points at hysterectomy are: know the CL anatomy; the distal section (as part of the CUSC) can provide vaginal vault support; the intermediate and proximal sections are surgically dangerous.
CBT for children with depressive symptoms: a meta-analysis.
Arnberg, Alexandra; Ost, Lars-Göran
2014-01-01
Pediatric depression entails a higher risk for psychiatric disorders, somatic complaints, suicide, and functional impairment later in life. Cognitive behavior therapy (CBT) is recommended for the treatment of depression in children, yet research is based primarily on adolescents. The present meta-analysis investigated the efficacy of CBT in children aged 8-12 years with regard to depressive symptoms. We included randomized controlled trials of CBT with participants who had an average age of ≤ 12 years and were diagnosed with either depression or reported elevated depressive symptoms. The search resulted in 10 randomized controlled trials with 267 participants in intervention and 256 in comparison groups. The mean age of participants was 10.5 years. The weighted between-group effect size for CBT was moderate, Cohen's d = 0.66. CBT outperformed both attention placebo and wait-list, although there was a significant heterogeneity among studies with regard to effect sizes. The weighted within-group effect size for CBT was large, d = 1.02. Earlier publication year, older participants, and more treatment sessions were associated with a larger effect size. In conclusion, the efficacy of CBT in the treatment of pediatric depression symptoms was supported. Differences in efficacy, methodological shortcomings, and lack of follow-up data limit the present study and indicate areas in need of improvement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, Xuedan; Diroll, Benjamin T.; Cho, Wooje
Quasi-two-dimensional nanoplatelets (NPLs) possess fundamentally different excitonic properties from zero-dimensional quantum dots. We study lateral size-dependent photon emission statistics and carrier dynamics of individual NPLs using second-order photon correlation (g( 2)(τ)) spectroscopy and photoluminescence (PL) intensity-dependent lifetime analysis. Room-temperature radiative lifetimes of NPLs can be derived from maximum PL intensity periods in PL time traces. It first decreases with NPL lateral size and then stays constant, deviating from the electric dipole approximation. Analysis of the PL time traces further reveals that the single exciton quantum yield in NPLs decreases with NPL lateral size and increases with protecting shell thickness, indicatingmore » the importance of surface passivation on NPL emission quality. Second-order photon correlation (g( 2)(τ)) studies of single NPLs show that the biexciton quantum yield is strongly dependent on the lateral size and single exciton quantum yield of the NPLs. In large NPLs with unity single exciton quantum yield, the corresponding biexciton quantum yield can reach unity. In conclusion, these findings reveal that by careful growth control and core–shell material engineering, NPLs can be of great potential for light amplification and integrated quantum photonic applications.« less
Ma, Xuedan; Diroll, Benjamin T.; Cho, Wooje; ...
2017-08-08
Quasi-two-dimensional nanoplatelets (NPLs) possess fundamentally different excitonic properties from zero-dimensional quantum dots. We study lateral size-dependent photon emission statistics and carrier dynamics of individual NPLs using second-order photon correlation (g( 2)(τ)) spectroscopy and photoluminescence (PL) intensity-dependent lifetime analysis. Room-temperature radiative lifetimes of NPLs can be derived from maximum PL intensity periods in PL time traces. It first decreases with NPL lateral size and then stays constant, deviating from the electric dipole approximation. Analysis of the PL time traces further reveals that the single exciton quantum yield in NPLs decreases with NPL lateral size and increases with protecting shell thickness, indicatingmore » the importance of surface passivation on NPL emission quality. Second-order photon correlation (g( 2)(τ)) studies of single NPLs show that the biexciton quantum yield is strongly dependent on the lateral size and single exciton quantum yield of the NPLs. In large NPLs with unity single exciton quantum yield, the corresponding biexciton quantum yield can reach unity. In conclusion, these findings reveal that by careful growth control and core–shell material engineering, NPLs can be of great potential for light amplification and integrated quantum photonic applications.« less
Peller, L
1977-02-08
The free-energy change of phosphodiester bond formation from nucleoside triphosphates is more favorable than with nucleoside diphosphates as substrates. Base-stacking interactions can make significant contributions to both delta G degrees ' values. Pyrophosphate hydrolysis when it accompanies the former reaction dominates all thermodynamic considerations. Three experimental situations are discussed in which high-molecular-weight polynucleotides are synthesized without a strong driving force for covalent bond formation. For one of these, a kinetic scheme is presented which encompasses an early narrow Poisson distribution of chain lengths with ultimate passage to a disperse equilibrium population of chain sizes. Hydrolytic removal of pyrophosphate expands the time scale for this undesirable process by a factor of 10(9), while it enormously elevates the thermodynamic ceiling for the average degrees of polymerization in the other two examples. The electron micrographically revealed broad size population from an early study of partial replication of a T7 DNA template is found to adhere (fortuitously) to a disperse most probable representation. Some possible origins are examined for the branched structures in this product, as well as in a later investigation of replication of this nucleic acid. The achievement of both very high molecular weights and sharply peaked size distributions in polynucleotides synthesized in vitro will require coupling to inorganic pyrophosphatase action as in vivo.
Wagner, Pablo; Ortiz, Cristian; Vela, Omar; Arias, Paul; Zanolli, Diego; Wagner, Emilio
2016-09-01
Tibialis posterior (TP) tendon transfer through the interosseous membrane is commonly performed in Charcot-Marie-Tooth disease. In order to avoid entrapment of this tendon, no clear recommendation relative to the interosseous membrane (IOM) incision size has been made. Analyze the TP size at the transfer level and therefore determine the most adequate IOM window size to avoid muscle entrapment. Eleven lower extremity magnetic resonances were analyzed. TP muscle measurements were made in axial views, obtaining the medial-lateral and antero-posterior diameter at various distances from the medial malleolus tip. The distance from the posterior to anterior compartment was also measured. These measurements were applied to a mathematical model to predict the IOM window size necessary to allow an ample TP passage in an oblique direction. The average tendon diameter (confidence-interval) at 15cm proximal to the medial malleolus tip was 19.47mm (17.47-21.48). The deep posterior compartment to anterior compartment distance was 10.97mm (9.03-12.90). Using a mathematical model, the estimated IOM window size ranges from 4.2 to 4.9cm. The IOM window size is of utmost importance in trans-membrane TP transfers, given that if equal or smaller than the transposed tendon oblique diameter, a high entrapment risk exists. A membrane window of 5cm or 2.5 times the size of the tendon diameter should be performed in order to theoretically diminish this complication. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
van Eijk, Ruben P A; Eijkemans, Marinus J C; Ferguson, Toby A; Nikolakopoulos, Stavros; Veldink, Jan H; van den Berg, Leonard H
2018-01-01
Objectives Plasma creatinine is a predictor of survival in amyotrophic lateral sclerosis (ALS). It remains, however, to be established whether it can monitor disease progression and serve as surrogate endpoint in clinical trials. Methods We used clinical trial data from three cohorts of clinical trial participants in the LITRA, EMPOWER and PROACT studies. Longitudinal associations between functional decline, muscle strength and survival with plasma creatinine were assessed. Results were translated to trial design in terms of sample size and power. Results A total of 13 564 measurements were obtained for 1241 patients. The variability between patients in rate of decline was lower in plasma creatinine than in ALS functional rating scale–Revised (ALSFRS-R; p<0.001). The average rate of decline was faster in the ALSFRS-R, with less between-patient variability at baseline (p<0.001). Plasma creatinine had strong longitudinal correlations with the ALSFRS-R (0.43 (0.39–0.46), p<0.001), muscle strength (0.55 (0.51–0.58), p<0.001) and overall mortality (HR 0.88 (0.86–0.91, p<0.001)). Using plasma creatinine as outcome could reduce the sample size in trials by 21.5% at 18 months. For trials up to 10 months, the ALSFRS-R required a lower sample size. Conclusions Plasma creatinine is an inexpensive and easily accessible biomarker that exhibits less variability between patients with ALS over time and is predictive for the patient’s functional status, muscle strength and mortality risk. Plasma creatinine may, therefore, increase the power to detect treatment effects and could be incorporated in future ALS clinical trials as potential surrogate outcome. PMID:29084868
Prabakaran, Ashok Daniel; Karakkat, Jimsheena Valiyakath; Vijayan, Ranjit; Chalissery, Jisha; Ibrahim, Marwa F; Kaimala, Suneesh; Adeghate, Ernest A; Al-Marzouqi, Ahmed Hassan; Ansari, Suraiya Anjum; Mensah-Brown, Eric; Emerald, Bright Starling
2018-03-01
Although the existence of a close relationship between the early maternal developmental environment, fetal size at birth and the risk of developing disease in adulthood has been suggested, most studies, however, employed experimentally induced intrauterine growth restriction as a model to link this with later adult disease. Because embryonic size variation also occurs under normal growth and differentiation, elucidating the molecular mechanisms underlying these changes and their relevance to later adult disease risk becomes important. The birth weight of rat pups vary according to the uterine horn positions. Using birth weight as a marker, we compared two groups of rat pups - lower birth weight (LBW, 5th to 25th percentile) and average birth weight (ABW, 50th to 75th percentile) - using morphological, biochemical and molecular biology, and genetic techniques. Our results show that insulin metabolism, Pi3k/Akt and Pparγ signaling and the genes regulating growth and metabolism are significantly different in these groups. Methylation at the promoter of the InsII ( Ins2 ) gene and DNA methyltransferase 1 in LBW pups are both increased. Additionally, the Dnmt1 repressor complex, which includes Hdac1, Rb (Rb1) and E2f1, was also upregulated in LBW pups. We conclude that the Dnmt1 repressor complex, which regulates the restriction point of the cell cycle, retards the rate at which cells traverse the G1 or G0 phase of the cell cycle in LBW pups, thereby slowing down growth. This regulatory mechanism mediated by Dnmt1 might contribute to the production of small-size pups and altered physiology and pathology in adult life. © 2018. Published by The Company of Biologists Ltd.
Prabakaran, Ashok Daniel; Karakkat, Jimsheena Valiyakath; Chalissery, Jisha; Ibrahim, Marwa F.; Kaimala, Suneesh; Adeghate, Ernest A.; Al-Marzouqi, Ahmed Hassan; Ansari, Suraiya Anjum
2018-01-01
ABSTRACT Although the existence of a close relationship between the early maternal developmental environment, fetal size at birth and the risk of developing disease in adulthood has been suggested, most studies, however, employed experimentally induced intrauterine growth restriction as a model to link this with later adult disease. Because embryonic size variation also occurs under normal growth and differentiation, elucidating the molecular mechanisms underlying these changes and their relevance to later adult disease risk becomes important. The birth weight of rat pups vary according to the uterine horn positions. Using birth weight as a marker, we compared two groups of rat pups – lower birth weight (LBW, 5th to 25th percentile) and average birth weight (ABW, 50th to 75th percentile) – using morphological, biochemical and molecular biology, and genetic techniques. Our results show that insulin metabolism, Pi3k/Akt and Pparγ signaling and the genes regulating growth and metabolism are significantly different in these groups. Methylation at the promoter of the InsII (Ins2) gene and DNA methyltransferase 1 in LBW pups are both increased. Additionally, the Dnmt1 repressor complex, which includes Hdac1, Rb (Rb1) and E2f1, was also upregulated in LBW pups. We conclude that the Dnmt1 repressor complex, which regulates the restriction point of the cell cycle, retards the rate at which cells traverse the G1 or G0 phase of the cell cycle in LBW pups, thereby slowing down growth. This regulatory mechanism mediated by Dnmt1 might contribute to the production of small-size pups and altered physiology and pathology in adult life. PMID:29434026
Bag, Sadhan; Joshi, Anil; Naqvi, S M K; Mittal, J P
2004-08-01
The objectives were to assess the effect of post-thaw in vitro incubation on motion characteristics and acrosomal integrity of ram spermatozoa of native Malpura and Bharat Merino breeds maintained under a semi-arid tropical environment. Good quality semen samples of both breeds were diluted, packaged in medium-sized straws, and frozen under controlled conditions. Straws were thawed at 60 degrees C for 10s and thawed samples were incubated at 37 degrees C for 4h. Post-thaw motion characteristics and acrosomal integrity of incubated spermatozoa were assessed (by computer-aided semen analysis and Giemsa staining, respectively) just prior to incubation and at hourly intervals thereafter. There was a significant effect of incubation time on motility characteristics and the proportion of spermatozoa with normal acrosomes; 81.4% (arcsin transformed value, 65.2) of spermatozoa were motile at the start of incubation, with 47.9% (arcsin transformed value, 44.4) motile after 4h. At the corresponding times, there were normal acrosomes in 65.8 (arcsin transformed value, 54.8) and 55.7% (arcsin transformed value, 48.9) of spermatozoa, respectively. The percentage straightness of spermatozoa varied during incubation (P < 0.01). However, there was no significant change in percentage linearity, curvilinear velocity, average path velocity, straight line velocity, lateral head displacement, and beat cross frequency of spermatozoa during incubation. There were no breed variations in any motility parameters during incubation, except percentage straightness (P < 0.05), lateral head displacement (P < 0.05) and beat cross frequency (P < 0.01). That sperm motility and acrosomal morphology were very acceptable immediately post-thaw and after 4h of incubation indicated the efficacy of cryopreserving ram spermatozoa under controlled conditions in medium-sized straws.
Emulsion oil droplet size significantly affects satiety: A pre-ingestive approach.
Lett, Aaron M; Norton, Jennifer E; Yeomans, Martin R
2016-01-01
Previous research has demonstrated that the manipulation of oil droplet size within oil-in-water emulsions significantly affects sensory characteristics, hedonics and expectations of food intake, independently of energy content. Smaller oil droplets enhanced perceived creaminess, increased Liking and generated greater expectations of satiation and satiety, indicating that creaminess is a satiety-relevant sensory cue within these systems. This paper extends these findings by investigating the effect of oil droplet size (d4,3: 2 and 50 μm) on food intake and appetite. Male participants (n = 34 aged 18-37; BMI of 22.7 ± 1.6 kg/m(2); DEBQ restricted eating score of 1.8 ± 0.1.) completed two test days, where they visited the laboratory to consume a fixed-portion breakfast, returning 3 h later for a "drink", which was the emulsion preload containing either 2 or 50 μm oil droplets. This was followed 20 min later with an ad libitum pasta lunch. Participants consumed significantly less at the ad libitum lunch after the preload containing 2 μm oil droplets than after the 50 μm preload, with an average reduction of 12% (62.4 kcal). Despite the significant differences in intake, no significant differences in sensory characteristics were noted. The findings show that the impact that an emulsion has on satiety can be enhanced without producing significantly perceivable differences in sensory properties. Therefore, by introducing a processing step which results in a smaller droplets, emulsion based liquid food products can be produced that enhance satiety, allowing covert functional redesign. Future work should consider the mechanism responsible for this effect. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kaplan, Zeev; Weiser, Mark; Reichenberg, Abraham; Rabinowitz, Jonathan; Caspi, Asaf; Bodner, Ehud; Zohar, Joseph
2002-01-31
High motivation and belief in a cause have been reported to be protective against posttraumatic stress disorder (PTSD), while below-average intellectual functioning and poor educational achievements have been reported to increase vulnerability to PTSD. The main goal of this study was to assess the effect of education, and intellectual and behavioral functioning on the risk for future PTSD. Data collected before exposure to trauma, on intellectual and behavioral functioning, and educational achievements of 901 male Israeli adolescents who had performed pre-induction screening tests by the Israeli Draft Board, and were later diagnosed with PTSD, were compared with a control group of adolescents who were not later diagnosed with PTSD. Future PTSD patients had significantly lower intelligence, fewer years of formal education and lower scores on a scale assessing motivation to serve in the military, in comparison with the control group, with effect sizes (ES) ranging from 0.14-0.34. In contrast, future PTSD patients scored significantly higher on a scale assessing social functioning, ES=0.13. However, when controlling for the differences in motivation to serve, all of these differences disappeared. In this cohort, although slightly below average intellectual functioning and formal education, and better social functioning, independently increased vulnerability to suffer from PTSD, these associations disappeared when the future PTSD patients' lower motivation to serve in the military was included in the analysis. This suggests that low motivation to serve in the military might increase vulnerability for PTSD.
Ttofi, Maria M; Farrington, David P; Lösel, Friedrich; Loeber, Rolf
2011-04-01
Although bullying and delinquency share similar risk factors, no previous systematic review has ever been conducted to examine possible links between school bullying and criminal offending later in life. To investigate the extent to which bullying perpetration at school predicts offending later in life, and whether this relation holds after controlling for other major childhood risk factors. Results are based on a thorough systematic review and meta-analysis of studies measuring school bullying and later offending. Effect sizes are based on both published and unpublished studies; longitudinal investigators of 28 studies have conducted specific analyses for our review. The probability of offending up to 11 years later was much higher for school bullies than for non-involved students [odds ratio (OR) = 2.50; 95% confidence interval (CI): 2.03-3.08]. Bullying perpetration was a significant risk factor for later offending, even after controlling for major childhood risk factors (OR = 1.82, 95% CI: 1.55-2.14). Effect sizes were smaller when the follow-up period was longer and larger when bullying was assessed in older children. The age of participants when outcome measures were taken was negatively related with effect sizes. Finally, the summary effect size did not decrease much as the number of controlled risk factors increased. School bullying is a strong and specific risk factor for later offending. Effective anti-bullying programmes should be promoted, and could be viewed as a form of early crime prevention. Such programmes would have a high benefit : cost ratio. Copyright © 2011 John Wiley & Sons, Ltd.
Cirino, Lauren A; Miller, Christine W
2017-01-17
Many insects are influenced by the phenology of their host plants. In North Central Florida, Narnia femorata (Hemiptera: Coreidae) spends its entire life cycle living and feeding on Opuntia mesacantha ssp. lata . This cactus begins producing flower buds in April that lead to unripe green fruit in June that ripen into red fruit through December. Many morphological and behavioral characteristics of N. femorata are known to be affected by cactus phenology in a controlled laboratory setting, including the degree of sexual dimorphism and mating behavior. Our goal with this study was to determine if similar phenotypic changes of N. femorata occurred over time in the wild, and the extent to which these changes were concordant with phenological changes in its host plant. Further, we investigate the length of the insect mouthparts (beak) over time. Ongoing work has suggested that beak length may change across cohorts of developing insects in response to feeding deep within cactus fruit where seed and pulp depth decrease as the fruit ripens. Our results revealed a drop in cactus fruit abundance between the months of July through October 2015 as cactus fruits turned red and ripened. Simultaneously, the average body size of both males and females of N. femorata declined at two sampled sites. Male hind femora (a sexually-selected weapon) decreased disproportionately in size over time so that males later in the year had relatively smaller hind femora for their body size. The sex-specific patterns of morphological change led to increased sexual-size dimorphism and decreased sexual dimorphism for hind femora later in the year. Further, we found that beak length decreased across cohorts of insects as cactus fruit ripened, suggesting phenotypic plasticity in mouthpart length. Behavioral studies revealed that female readiness to mate increased as the season progressed. In sum, we found pronounced changes in the phenotypes of these insects in the field. Although this study is far from comprehensive, it provides tantalizing patterns that suggest many directions for future research.
Jang, Gyoung Gug; Song, Bo; Moon, Kyoung-sik; ...
2017-04-17
Graphene-based electrodes for high performance supercapacitors are developed by taking advantage of particle size control, large mass loading, and surface functionalization of reduced graphene oxide (rGO) sheets. Two controlled sizes of graphene sheets (100 nm vs. 45 μm average lateral dimensions) were prepared to study two-electrode system performance. The nano-size graphenes led to the formation of mesoporous films, resulting in higher capacitance, better capacitance retension and lower equivalent series resistance (ESR), indicating better surface usability for diffusion and accessibility of electrolyte ions by shortening transport paths (compared with horizontally stacked films from micro-sized graphenes). For studies using an aqueous electrolyte,more » the maximum specific capacitance of nano-rGO film was 302 F/g (at 1 A/g with 4.3 mg/cm 2 of mass loading), which was ~2.4 times higher than micro-rGO film, and achieved a ~67% reduced ESR. With an organic electrolyte, the nano-rGO delivered ~4.2 times higher capacitance (115 F/g at 2 A/g with 4.3 mg/cm 2), 4.0 times lower IR drops, and an order-of-magnitude lower charge-transfer resistance with an energy density of 18.7 Wh/kg. Finally, the results of this work indicate that the size control of graphene sheet particles for film deposit electrodes can be a simple but effective approach to improve supercapacitor performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jang, Gyoung Gug; Song, Bo; Moon, Kyoung-sik
Graphene-based electrodes for high performance supercapacitors are developed by taking advantage of particle size control, large mass loading, and surface functionalization of reduced graphene oxide (rGO) sheets. Two controlled sizes of graphene sheets (100 nm vs. 45 μm average lateral dimensions) were prepared to study two-electrode system performance. The nano-size graphenes led to the formation of mesoporous films, resulting in higher capacitance, better capacitance retension and lower equivalent series resistance (ESR), indicating better surface usability for diffusion and accessibility of electrolyte ions by shortening transport paths (compared with horizontally stacked films from micro-sized graphenes). For studies using an aqueous electrolyte,more » the maximum specific capacitance of nano-rGO film was 302 F/g (at 1 A/g with 4.3 mg/cm 2 of mass loading), which was ~2.4 times higher than micro-rGO film, and achieved a ~67% reduced ESR. With an organic electrolyte, the nano-rGO delivered ~4.2 times higher capacitance (115 F/g at 2 A/g with 4.3 mg/cm 2), 4.0 times lower IR drops, and an order-of-magnitude lower charge-transfer resistance with an energy density of 18.7 Wh/kg. Finally, the results of this work indicate that the size control of graphene sheet particles for film deposit electrodes can be a simple but effective approach to improve supercapacitor performance.« less
Li, Qingfeng; Zan, Tao; Gu, Bin; Liu, Kai; Shen, Guoxiong; Xie, Yun; Weng, Rui
2009-01-01
Resurfacing of facial massive soft tissue defect is a formidable challenge because of the unique character of the region and the limitation of well-matched donor site. In this report, we introduce a technique for using the prefabricated cervicothoracic skin flap for facial resurfacing, in an attempt to meet the principle of flap selection in face reconstructive surgery for matching the color and texture, large dimension, and thinner thickness (MLT) of the recipient. Eleven patients with massive facial scars underwent resurfacing procedures with prefabricated cervicothoracic flaps. The vasculature of the lateral thigh fascial flap, including the descending branch of the lateral femoral circumflex vessels and the surrounding muscle fascia, was used as the vascular carrier, and the pedicles of the fascial flap were anastomosed to either the superior thyroid or facial vessels in flap prefabrication. A tissue expander was placed beneath the fascial flap to enlarge the size and reduce the thickness of the flap. The average size of the harvested fascia flap was 6.5 x 11.7 cm. After a mean interval of 21.5 weeks, the expanders were filled to a mean volume of 1,685 ml. The sizes of the prefabricated skin flaps ranged from 12 x 15 cm to 15 x 32 cm. The prefabricated skin flaps were then transferred to the recipient site as pedicled flaps for facial resurfacing. All facial soft tissue defects were successfully covered by the flaps. The donor sites were primarily closed and healed without complications. Although varied degrees of venous congestion were developed after flap transfers, the marginal necrosis only occurred in two cases. The results in follow-up showed most resurfaced faces restored natural contour and regained emotional expression. MLT is the principle for flap selection in resurfacing of the massive facial soft tissue defect. Our experience in this series of patients demonstrated that the prefabricated cervicothoracic skin flap could be a reliable alternative tool for resurfacing of massive facial soft tissue defects. (c) 2009 Wiley-Liss, Inc. Microsurgery, 2009.
Food photography. I: The perception of food portion size from photographs.
Nelson, M; Atkinson, M; Darbyshire, S
1994-11-01
Fifty-one male and female volunteers aged 18-90 years from a wide variety of social and occupational backgrounds completed 7284 assessments of portion size in relation to food photographs. Subjects were shown six portion sizes (two small, two medium and two large) for each of six foods, and asked to compare the amount on the plate in front of them to (a) a series of eight photographs showing weights of portions from the 5th to the 95th centile of portion size (British Adult Dietary Survey), or (b) a single photograph of the average (median) portion size. Photographs were prepared either in colour or in black and white, and in two different sizes. The order of presentation of foods; use of black and white or colour; the size of photographs; and presentation of eight or average photographs were each randomized independently. On average, the mean differences between the portion size presented and the estimate of portion size using the photographs varied from -8 to +6 g (-4 to +5%) for the series of eight photographs, and from -34 to -1 g (-23 to +9%) for the single average photograph. Large portion sizes tended to be underestimated more than medium or small portion sizes, especially when using the average photograph (from -79 to -14 g, -37 to -13%). Being female, 65 years and over, or retired, or seeing photographs in colour, were all associated with small but statistically significant overestimations of portion size. Having a body mass index > or = 30 kg/m2 was associated with an 8% underestimate of portion size. We conclude that use of a series of eight photographs is associated with relatively small errors in portion size perception, whereas use of an average photograph is consistently associated with substantial underestimation across a variety of foods.
Optimised in vitro applicable loads for the simulation of lateral bending in the lumbar spine.
Dreischarf, Marcel; Rohlmann, Antonius; Bergmann, Georg; Zander, Thomas
2012-07-01
In in vitro studies of the lumbar spine simplified loading modes (compressive follower force, pure moment) are usually employed to simulate the standard load cases flexion-extension, axial rotation and lateral bending of the upper body. However, the magnitudes of these loads vary widely in the literature. Thus the results of current studies may lead to unrealistic values and are hardly comparable. It is still unknown which load magnitudes lead to a realistic simulation of maximum lateral bending. A validated finite element model of the lumbar spine was used in an optimisation study to determine which magnitudes of the compressive follower force and bending moment deliver results that fit best with averaged in vivo data. The best agreement with averaged in vivo measured data was found for a compressive follower force of 700 N and a lateral bending moment of 7.8 Nm. These results show that loading modes that differ strongly from the optimised one may not realistically simulate maximum lateral bending. The simplified but in vitro applicable loading cannot perfectly mimic the in vivo situation. However, the optimised magnitudes are those which agree best with averaged in vivo measured data. Its consequent application would lead to a better comparability of different investigations. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
Kim, Mi Ra; Kim, Sang Soo; Huh, Jung Eun; Lee, Byung Joo; Lee, Jin Choon; Jeon, Yun Kyung; Kim, Bo Hyun; Kim, Seong Jang; Wang, Soo Geun; Kim, Yong Ki; Kim, In Joo
2013-01-01
Obesity is correlated with numerous diseases, including thyroid cancer, but the clinical significance of obesity with regard to the clinical characteristics of thyroid cancer remains unclear. Neck circumference is an index of upper-body adipose tissue distribution. In total, 401 patients with papillary thyroid carcinoma (PTC) measuring ≤ 2 cm were included. Neck circumference was measured horizontally at the level just below the thyroid cartilage on preoperative neck computed tomographic images. Neck circumference correlated significantly with tumor size in men (p = 0.001) but not in women (p = 0.930). Body mass index (BMI) did not significantly correlate with tumor size in either sex. Neck circumference was significantly larger in men with lateral lymph node (LN) metastasis than in those without (p = 0.004). Neck circumference and BMI did not differ significantly in women according to other factors such as tumor size, multifocality, extrathyroid extension, and LN metastasis. Tumor size and the prevalence of lateral LN metastasis in men tended to increase in the middle/large neck circumference subgroup compared with those in the low neck circumference subgroup. Multivariate logistic regression analysis revealed that neck circumference (p = 0.009) was a predictor for the presence of lateral LN metastasis in men. BMI was not a predictive factor for lateral LN involvement in either sex. Neck circumference, an indicator of central or visceral obesity but not BMI, may be associated with some prognostic factors in men with small PTC.
NASA Technical Reports Server (NTRS)
Barrentine, E. M.; Brandl, D. E.; Brown, A. D.; Denis, K. L.; Fionkbeiner, F. M.; Hsieh, W. T.; Nagler, P. C.; Stevenson, T. R.; Timble, P. T.; U-Yen, K.
2012-01-01
Recent measurements of micron-sized Mo/Au bilayer Transition Edge Sensors (TESs) have demonstrated that the TES can behave like an S-S'-S weak link due to the lateral proximity effect from superconducting leads. In this regime the Tc is a function of bias current, and the effective Tc shifts from the bilayer Tc towards the lead Tc. We explore the idea that a micron-sized S-N-S weak link could provide a new method to engineer the TES Tc. This method would be particularly useful when small size requirements for a bilayer TES (such as for a hot-electron microbolometer) lead to undesirable shifts in the bilayer Te. We present measurements of a variety of micron-sized normal Au 'TES' devices with Nb leads. We find no evidence of a superconducting transition in the Au film of these devices, in dramatic contrast to the strong lateral proximity effect seen in micron-sized Mo/Au bilayer devices. The absence of a transition in these devices is also in disagreement with theoretical predictions for S-N-S weak links. We hypothesize that a finite contact resistance between the Nb and Au may be weakening the effect. We conclude that the use of the lateral proximity effect to create a superconducting transition will be difficult given current fabrication procedures.
40 CFR 600.503-78 - Abbreviations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon...
40 CFR 600.505-78 - Recordkeeping.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Y; Hsi, W; Zhao, J
2016-06-15
Purpose: The Gaussian model for the lateral profiles in air is crucial for an accurate treatment planning system. The field size dependence of dose and the lateral beam profiles of scanning proton and carbon ion beams are due mainly to particles undergoing multiple Coulomb scattering in the beam line components and secondary particles produced by nuclear interactions in the target, both of which depend upon the energy and species of the beam. In this work, lateral profile shape parameters were fitted to measurements of field size dependence dose at the center of field size in air. Methods: Previous studies havemore » employed empirical fits to measured profile data to significantly reduce the QA time required for measurements. From this approach to derive the weight and sigma of lateral profiles in air, empirical model formulations were simulated for three selected energies for both proton and carbon beams. Results: The 20%–80% lateral penumbras predicted by the double model for proton and single model for carbon with the error functions agreed with the measurements within 1 mm. The standard deviation between measured and fitted field size dependence of dose for empirical model in air has a maximum accuracy of 0.74% for proton with double Gaussian, and of 0.57% for carbon with single Gaussian. Conclusion: We have demonstrated that the double Gaussian model of lateral beam profiles is significantly better than the single Gaussian model for proton while a single Gaussian model is sufficient for carbon. The empirical equation may be used to double check the separately obtained model that is currently used by the planning system. The empirical model in air for dose of spot scanning proton and carbon ion beams cannot be directly used for irregular shaped patient fields, but can be to provide reference values for clinical use and quality assurance.« less
NASA Astrophysics Data System (ADS)
Nasta, Paolo; Penna, Daniele; Brocca, Luca; Zuecco, Giulia; Romano, Nunzio
2018-02-01
Indirect measurements of field-scale (hectometer grid-size) spatial-average near-surface soil moisture are becoming increasingly available by exploiting new-generation ground-based and satellite sensors. Nonetheless, modeling applications for water resources management require knowledge of plot-scale (1-5 m grid-size) soil moisture by using measurements through spatially-distributed sensor network systems. Since efforts to fulfill such requirements are not always possible due to time and budget constraints, alternative approaches are desirable. In this study, we explore the feasibility of determining spatial-average soil moisture and soil moisture patterns given the knowledge of long-term records of climate forcing data and topographic attributes. A downscaling approach is proposed that couples two different models: the Eco-Hydrological Bucket and Equilibrium Moisture from Topography. This approach helps identify the relative importance of two compound topographic indexes in explaining the spatial variation of soil moisture patterns, indicating valley- and hillslope-dependence controlled by lateral flow and radiative processes, respectively. The integrated model also detects temporal instability if the dominant type of topographic dependence changes with spatial-average soil moisture. Model application was carried out at three sites in different parts of Italy, each characterized by different environmental conditions. Prior calibration was performed by using sparse and sporadic soil moisture values measured by portable time domain reflectometry devices. Cross-site comparisons offer different interpretations in the explained spatial variation of soil moisture patterns, with time-invariant valley-dependence (site in northern Italy) and hillslope-dependence (site in southern Italy). The sources of soil moisture spatial variation at the site in central Italy are time-variant within the year and the seasonal change of topographic dependence can be conveniently correlated to a climate indicator such as the aridity index.
Effects of set-size and lateral masking in visual search.
Põder, Endel
2004-01-01
In the present research, the roles of lateral masking and central processing limitations in visual search were studied. Two search conditions were used: (1) target differed from distractors by presence/absence of a simple feature; (2) target differed by relative position of the same components only. The number of displayed stimuli (set-size) and the distance between neighbouring stimuli were varied as independently as possible in order to measure the effect of both. The effect of distance between stimuli (lateral masking) was found to be similar in both conditions. The effect of set-size was much larger for relative position stimuli. The results support the view that perception of relative position of stimulus components is limited mainly by the capacity of central processing.
Outcomes of laparoscopic adrenalectomy. Clinical experience with 68 patients.
Pugliese, Raffaele; Boniardi, Marco; Sansonna, Fabio; Maggioni, Dario; De Carli, Stefano; Costanzi, Andrea; Scandroglio, Ildo; Ferrari, Giovanni Carlo; Di Lernia, Stefano; Magistro, Carmelo; Loli, Paola; Grossrubatscher, Erika
2008-07-01
The aim of this study was to analyze feasibility and outcomes of laparoscopic adrenalectomy (LA). Pathology, size and bilateral site of lesions were considered. Between December 1998 and May 2007 in our institution a total of 68 patients of mean age of 53 years underwent unilateral (n=57) or bilateral (n=11) LA. Adrenal masses averaged 5.4cm in size (range 1.2-13cm) and 56.7g in weight (range 10-265) including 71 benign and 8 malignant lesions. A total of 79 adrenal glands were resected, 44 right sided and 35 left sided. Removal was complete in 77 cases and partial (sparing adrenalectomy) in 1 patient affected by bilateral pheochomocytoma. Three left adrenalectomies for pheochromocytoma were robot-assisted. The transperitoneal lateral approach was preferred and the posterior retroperitoneal approach was adopted in 5 patients. The mean duration of surgery for each LA was 138+/-90min and 3.8 trocar were used on average (range 3-6). Conversion was needed in 3 cases owing to difficult dissection of large masses. Estimated mean blood loss for each LA was 95+/-30ml and it was greater for bilateral LA. Mortality was nil and morbidity was 5.8%. The average length of hospital stay (LOS) in surgical unit was 4+/-2.4 days (range 2-8). Patients affected by hormone secreting or bilateral lesions, by unilateral or bilateral pheochromocytoma and by bilateral Cushing's disease were transferred to the endocrinological ward so that their overall hospital stay was prolonged to 9+/-2.8 days on average (range 7-17). Mean duration of follow-up of patients was 38 months (range 2-100) and demonstrated acceptable endocrine results. Three primary cortical carcinomas were discovered as chance findings on histologic examination. While long-term results after LA for cortical carcinomas were poor and LA is not recommended in such cases, long-term results after LA for adrenal metastases were encouraging.
NASA Astrophysics Data System (ADS)
Hazenberg, P.; Broxton, P. D.; Brunke, M.; Gochis, D.; Niu, G. Y.; Pelletier, J. D.; Troch, P. A. A.; Zeng, X.
2015-12-01
The terrestrial hydrological system, including surface and subsurface water, is an essential component of the Earth's climate system. Over the past few decades, land surface modelers have built one-dimensional (1D) models resolving the vertical flow of water through the soil column for use in Earth system models (ESMs). These models generally have a relatively coarse model grid size (~25-100 km) and only account for sub-grid lateral hydrological variations using simple parameterization schemes. At the same time, hydrologists have developed detailed high-resolution (~0.1-10 km grid size) three dimensional (3D) models and showed the importance of accounting for the vertical and lateral redistribution of surface and subsurface water on soil moisture, the surface energy balance and ecosystem dynamics on these smaller scales. However, computational constraints have limited the implementation of the high-resolution models for continental and global scale applications. The current work presents a hybrid-3D hydrological approach is presented, where the 1D vertical soil column model (available in many ESMs) is coupled with a high-resolution lateral flow model (h2D) to simulate subsurface flow and overland flow. H2D accounts for both local-scale hillslope and regional-scale unconfined aquifer responses (i.e. riparian zone and wetlands). This approach was shown to give comparable results as those obtained by an explicit 3D Richards model for the subsurface, but improves runtime efficiency considerably. The h3D approach is implemented for the Delaware river basin, where Noah-MP land surface model (LSM) is used to calculated vertical energy and water exchanges with the atmosphere using a 10km grid resolution. Noah-MP was coupled within the WRF-Hydro infrastructure with the lateral 1km grid resolution h2D model, for which the average depth-to-bedrock, hillslope width function and soil parameters were estimated from digital datasets. The ability of this h3D approach to simulate the hydrological dynamics of the Delaware River basin will be assessed by comparing the model results (both hydrological performance and numerical efficiency) with the standard setup of the NOAH-MP model and a high-resolution (1km) version of NOAH-MP, which also explicitly accounts for lateral subsurface and overland flow.
Balcom, B J; Petersen, N O
1993-01-01
We have systematically investigated the probe size and shape dependence of lateral diffusion in model dimyristoyl phosphatidylcholine membranes. Linear hydrophobic polymers, which differ in length by an order of magnitude, were used to explore the effect on the lateral diffusion coefficient of hydrodynamic restrictions in the bilayer interior. The polymers employed are isoprenoid alcohols--citronellol, solanesol, and dolichol. Tracer lateral diffusion coefficients were measured by fluorescence photobleaching recovery. Despite the large difference in lengths, the nitrobenzoxadiazole labelled alcohols all diffuse at the rate of lipid self-diffusion (5.0 x 10(-12) m2 s-1, 29 degrees C) in the liquid crystal phase. Companion measurements in isotropic polymer solution, in gel phase lipid membranes and with nonpolar fluorescent polyaromatic hydrocarbons, show a marked dependence of the lateral diffusion coefficient on the probe molecule size. Our results in the liquid crystal phase are in accord with free area theory which asserts that lateral diffusion in the membrane is restricted by the surface-free area. Probe molecules which are significantly longer than the host phospholipid, seven times longer in the case of dolichol, are still restricted in their lateral motion by the surface properties of the bilayer in the liquid crystal phase. Fluorescence quenching experiments indicate that the nitrobenzoxadiazole label does not reside at the aqueous interface, although it must reside in close proximity according to the diffusion measurements. PMID:8218892
NASA Technical Reports Server (NTRS)
Mulholland, J. Derral; Simon, Charles G.; Cooke, William J.; Oliver, John P.; Misra, V.
1992-01-01
The electronic sensors of the Interplanetary Dust Experiment (IDE) recorded precise impact times and approximate directions for submicron to approximately 100-micron size particles on all six primary sides of the spacecraft for the first 346 days of the Long Duration Exposure Facility (LDEF) orbital mission. Previously-reported analyses of the timed impact data have established their spatio-temporal features, including the demonstration that a preponderance of the particles in this regime are orbital debris and that a large fraction of the debris particles are encountered as megameter-size clouds, some of which persist for long times. Short-term fluxes within such clouds can rise several orders of magnitude above the long-term average. These finding are consistent with the results of the first catastrophic hypervelocity laboratory impacts on a real satellite, recently reported in the press. Analysis continues on the geometric and evolutionary characteristics of these clouds, as well as on the isolation and characterization of the natural micrometeoroid component in the IDE data, but the unexpectedly large short-term variations in debris flux raises the question of how representative an indication of the multi-year average flux is given by the nearly one year of timed data. It has, therefore, always been one of the goals of IDE to conduct an optical survey of the craters on the IDE detectors, to obtain full-mission fluxes for comparisons with the timed data. This work is underway, and the results presently in hand are significant. Optical scanning of the ram and wake (East and West) panels is complete, and it is clear that the first year was in some respects not representative of the subsequent years. The 5.75-year average flux on East panel was 90 percent of the value predicted by the average flux recorded during the first year, while it was only 34 percent on West panel. This suggests that western hemisphere spacecraft launches are a major contributor to the long-term flux and that their contribution is primarily in the smaller end of the size distribution. This conclusion follows from the fact that a closely-spaced series of launch failures (Titan, Delta, Ariane, and Challenger) caused a virtual hiatus in launch activity during a large part of the later years of the LDEF mission. We hope to provide a quantification of the particle size distribution function in this case.
The use of tibial tuberosity-trochlear groove indices based on joint size in lower limb evaluation.
Ferlic, Peter Wilhelm; Runer, Armin; Dirisamer, Florian; Balcarek, Peter; Giesinger, Johannes; Biedermann, Rainer; Liebensteiner, Michael Christian
2018-05-01
The correlation between tibial tuberosity-trochlear groove distance (TT-TG) and joint size, taking into account several different parameters of knee joint size as well as lower limb dimensions, is evaluated in order to assess whether TT-TG indices should be used in instead of absolute TT-TG values. This study comprised a retrospective analysis of knee CT scans, including 36 cases with patellofemoral instability (PFI) and 30 controls. Besides TT-TG, five measures of knee joint size were evaluated in axial CT slices: medio-lateral femur width, antero-posterior lateral condylar height, medio-lateral width of the tibia, width of the patella and the proximal-distal joint size (TT-TE). Furthermore, the length of the femur, the tibia and the total leg length were measured in the CT scanogram. Correlation analysis of TT-TG and the other parameters was done by calculating the Spearman correlation coefficient. In the PFI group lateral condylar height (r = 0.370), tibia width (r = 0.406) and patella width (r = 0.366) showed significant moderate correlations (p < 0.03) with TT-TG. Furthermore, we found a significant correlation between TT-TG and tibia length (r = 0.371) and total leg length (r = 381). The control group showed no significant correlation between TT-TG and knee joint size or between TT-TG and measures of lower limb length. Tibial tuberosity-trochlear groove distance correlates with several parameters of knee joint size and leg length in patients with patellofemoral instability. Application of indices determining TT-TG as a ratio of joint size could be helpful in establishing the indication for medial transfer of the tibial tuberosity in patients with PFI. Level III.
NASA Astrophysics Data System (ADS)
Burns, C. E.; Mountney, N. P.; Hodgson, D. M.; Colombera, L.
2017-04-01
Crevasse-splay deposits form a volumetrically significant component of many fluvial overbank successions (up to 90% in some successions).Yet the relationships between the morphological form of accumulated splay bodies and their internal facies composition remains poorly documented from ancient successions. This work quantifies lithofacies distributions and dimensions of exhumed crevasse-splay architectural elements in the Campanian Castlegate Sandstone and Neslen Formation, Mesaverde Group, Utah, USA, to develop a depositional model. Fluvial crevasse-splay bodies thin from 2.1 m (average) to 0.8 m (average) and fine from a coarsest recorded grain size of lower-fine sand to fine silt away from major trunk channel bodies. Internally, the preserved deposits of splays comprise laterally and vertically variable sandstone and siltstone facies associations: proximal parts are dominated by sharp and erosional-based sandstone-prone units, which may be structureless or may comprise primary current lineation on beds and erosional gutter casts; medial parts comprise sets of climbing-ripple strata and small scale deformed beds; distal parts comprise sets of lower-stage plane beds and complex styles of lateral grading into fine-grained floodbasin siltstones and coals. Lithofacies arrangements are used to establish the following: (i) recognition criteria for crevasse-splay elements; (ii) criteria for the differentiation between distal parts of crevasse-splay bodies and floodplain fines; and (iii) empirical relationships with which to establish the extent (ca. 500 m long by 1000 m wide) and overall semi-elliptical planform shape of crevasse-splay bodies. These relationships have been established by high-resolution stratigraphic correlation and palaeocurrent analysis to identify outcrop orientation with respect to splay orientation. This permits lateral changes in crevasse-splay facies architecture to be resolved. Facies models describing the sedimentology and architecture of crevasse-splay deposits preserved in floodplain successions serve as tools for determining both distance from and direction to major trunk channel sandbodies.
Adaptation to Antifaces and the Perception of Correct Famous Identity in an Average Face
Little, Anthony C.; Hancock, Peter J. B.; DeBruine, Lisa M.; Jones, Benedict C.
2011-01-01
Previous experiments have examined exposure to anti-identities (faces that possess traits opposite to an identity through a population average), finding that exposure to antifaces enhances recognition of the plus-identity images. Here we examine adaptation to antifaces using famous female celebrities. We demonstrate: that exposure to a color and shape transformed antiface of a celebrity increases the likelihood of perceiving the identity from which the antiface was manufactured in a composite face and that the effect shows size invariance (experiment 1), equivalent effects are seen in internet and laboratory-based studies (experiment 2), adaptation to shape-only antifaces has stronger effects on identity recognition than adaptation to color-only antifaces (experiment 3), and exposure to male versions of the antifaces does not influence the perception of female faces (experiment 4). Across these studies we found an effect of order where aftereffects were more pronounced in early than later trials. Overall, our studies delineate several aspects of identity aftereffects and support the proposal that identity is coded relative to other faces with special reference to a relatively sex-specific mean face representation. PMID:22363301
A discrete gust model for use in the design of wind energy conversion systems
NASA Technical Reports Server (NTRS)
Frost, W.; Turner, R. E.
1982-01-01
A discrete gust model has been designed which includes an expression for the number of times per unit time thy wind exceeds a specific value. This expression, based on Rice's (1944, 1945) number-of-crossings model, assumes that the yearly mean wind speed is averaged over a period of 10 minutes to 1 (one) hour. Vertical and lateral coherence functions are the basis for a mathematical filter which isolates atmospheric disturbances of a characteristic size (e. g., those which would completely engulf a rotor). Predictions are calculated usising the given definition of cut-off frequency, then they are compared with actual data, showing that the model is reliable. The expression is provided in a format such that it may be used for engineering design calculations.
Multiscale Modeling of Damage Processes in fcc Aluminum: From Atoms to Grains
NASA Technical Reports Server (NTRS)
Glaessgen, E. H.; Saether, E.; Yamakov, V.
2008-01-01
Molecular dynamics (MD) methods are opening new opportunities for simulating the fundamental processes of material behavior at the atomistic level. However, current analysis is limited to small domains and increasing the size of the MD domain quickly presents intractable computational demands. A preferred approach to surmount this computational limitation has been to combine continuum mechanics-based modeling procedures, such as the finite element method (FEM), with MD analyses thereby reducing the region of atomic scale refinement. Such multiscale modeling strategies can be divided into two broad classifications: concurrent multiscale methods that directly incorporate an atomistic domain within a continuum domain and sequential multiscale methods that extract an averaged response from the atomistic simulation for later use as a constitutive model in a continuum analysis.
Montazeri, Parisa; Vrijheid, Martine; Martinez, David; Basterrechea, Mikel; Fernandez-Somoano, Ana; Guxens, Monica; Iñiguez, Carmen; Lertxundi, Aitana; Murcia, Mario; Tardon, Adonina; Sunyer, Jordi; Valvi, Damaskini
2018-03-01
The objective of this study was to evaluate the associations between maternal metabolic parameters and early childhood BMI trajectories. Two thousand two hundred fifty-one children born in Spain between 2004 and 2008 were analyzed. Five BMI z score trajectories from birth to age 4 years were identified by using latent class growth analysis. Multinomial regression assessed the associations between maternal metabolic parameters and offspring's BMI trajectories. Children in the reference BMI trajectory had average size at birth followed by a slower BMI gain. Maternal prepregnancy obesity was associated with trajectories of accelerated BMI gain departing from either higher (relative risk ratio [RRR] = 1.77; 95% CI: 1.07-2.91) or lower size at birth (RRR = 1.91; 95% CI: 1.17-3.12). Gestational weight gain (GWG) above clinical guidelines was associated with a trajectory of higher birth size followed by accelerated BMI gain (RRR = 2.14; 95% CI: 1.53-2.97). Maternal serum triglycerides were negatively associated with BMI trajectories departing from lower birth sizes. Gestational diabetes, maternal serum cholesterol, and C-reactive protein were unrelated to children's BMI trajectories. Maternal prepregnancy obesity, GWG, and serum triglycerides are associated with longitudinal BMI trajectories in early childhood that may increase disease risk in later life. Health initiatives should promote healthy weight status before and during pregnancy to improve maternal and child health. © 2018 The Obesity Society.
NASA Astrophysics Data System (ADS)
Long, Yin; Zhang, Xiao-Jun; Wang, Kui
2018-05-01
In this paper, convergence and approximate calculation of average degree under different network sizes for decreasing random birth-and-death networks (RBDNs) are studied. First, we find and demonstrate that the average degree is convergent in the form of power law. Meanwhile, we discover that the ratios of the back items to front items of convergent reminder are independent of network link number for large network size, and we theoretically prove that the limit of the ratio is a constant. Moreover, since it is difficult to calculate the analytical solution of the average degree for large network sizes, we adopt numerical method to obtain approximate expression of the average degree to approximate its analytical solution. Finally, simulations are presented to verify our theoretical results.
Serrancolí, Gil; Kinney, Allison L.; Fregly, Benjamin J.; Font-Llagunes, Josep M.
2016-01-01
Though walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patient-specific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel two-level optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outer-level optimization adjusted time-invariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the inner-level optimization predicted time-varying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher lateral muscle forces and lateral optimal muscle fiber lengths but lower medial, central, and lateral normalized muscle fiber lengths compared to Approach A. These findings suggest that poorly calibrated model parameter values may be a major factor limiting the ability of neuromusculoskeletal models to predict knee contact and leg muscle forces accurately for walking. PMID:27210105
Smith, Ian O; McCabe, Laura R; Baumann, Melissa J
2006-01-01
Porous bone tissue engineering scaffolds were fabricated using both nano hydroxyapatite (nano HA) powder (20 nm average particle size) and micro HA powder (10 μm average particle size), resulting in sintered scaffolds of 59 vol% porosity and 8.6±1.9 μm average grain size and 72 vol% porosity and 588±55 nm average grain size, respectively. Scanning electron microscopy was used to measure both the grain size and pore size. MC3T3-E1 osteoblast (OB) attachment and proliferation on both nano HA and micro HA porous scaffolds were quantified. As expected, OB cell number was greater on nano HA scaffolds compared with similarly processed micro HA scaffolds 5 days after seeding, while OB attachment did not appear greater on the nano HA scaffolds (p<0.05). PMID:17722535
Uusberg, Helen; Peet, Krista; Uusberg, Andero; Akkermann, Kirsti
2018-03-17
Appearance-related attention biases are thought to contribute to body image disturbances. We investigated how preoccupation with body image is associated with attention biases to body size, focusing on the role of social comparison processes and automaticity. Thirty-six women varying on self-reported preoccupation compared their actual body size to size-modified images of either themselves or a figure-matched peer. Amplification of earlier (N170, P2) and later (P3, LPP) ERP components recorded under low vs. high concurrent working memory load were analyzed. Women with high preoccupation exhibited an earlier bias to larger bodies of both self and peer. During later processing stages, they exhibited a stronger bias to enlarged as well as reduced self-images and a lack of sensitivity to size-modifications of the peer-image. Working memory load did not affect these biases systematically. Current findings suggest that preoccupation with body image involves an earlier attention bias to weight increase cues and later over-engagement with own figure. Copyright © 2018 Elsevier B.V. All rights reserved.
Brain size and encephalization in early to Mid-Pleistocene Homo.
Rightmire, G Philip
2004-06-01
Important changes in the brain have occurred during the course of human evolution. Both absolute and relative size increases can be documented for species of Homo, culminating in the appearance of modern humans. One species that is particularly well-represented by fossil crania is Homo erectus. The mean capacity for 30 individuals is 973 cm(3). Within this group there is substantial variation, but brain size increases slightly in specimens from later time periods. Other Middle Pleistocene crania differ from those of Homo erectus. Characters of the facial skeleton, vault, and cranial base suggest that fossils from sites such as Arago Cave in France, the Sima de los Huesos in Spain, Bodo in Ethiopia, Broken Hill in Zambia, and perhaps Dali in China belong to the taxon Homo heidelbergensis. Ten of these mid-Quaternary hominins have brains averaging 1,206 cm(3) in volume, and many fall beyond the limits of size predicted for Homo erectus of equivalent age. When orbit height is used to construct an index of relative brain size, it is apparent that the (significant) increase in volume documented for the Middle Pleistocene individuals is not simply a consequence of larger body mass. Encephalization quotient values confirm this finding. These changes in absolute and relative brain size can be taken as further corroborative evidence for a speciation event, in which Homo erectus produced a daughter lineage. It is probable that Homo heidelbergensis originated in Africa or western Eurasia and then ranged widely across the Old World. Archaeological traces indicate that these populations differed in their technology and behavior from earlier hominins. Copyright 2003 Wiley-Liss, Inc.
Patient size and x-ray transmission in body CT.
Ogden, Kent; Huda, Walter; Scalzetti, Ernest M; Roskopf, Marsha L
2004-04-01
Physical characteristics were obtained for 196 patients undergoing chest and abdomen computed tomography (CT) examinations. Computed tomography sections for these patients having no evident pathology were analyzed to determine patient dimensions (AP and lateral), together with the average attenuation coefficient. Patient weights ranged from approximately 3 kg to about 120 kg. For chest CT, the mean Hounsfield unit (HU) fell from about -120 HU for newborns to about -300 HU for adults. For abdominal CT, the mean HU for children and normal-sized adults was about 20 HU, but decreased to below -50 HU for adults weighing more than 100 kg. The effective photon energy and percent energy fluence transmitted through a given patient size and composition was calculated for representative x-ray spectra at 80, 100, 120, and 140 kV tube potentials. A 70-kg adult scanned at 120 kVp transmits 2.6% of the energy fluence for chest and 0.7% for abdomen CT examinations. Reducing the patient size to 10 kg increases transmission by an order of magnitude. For 70 kg patients, effective energies in body CT range from approximately 50 keV at 80 kVp to approximately 67 keV at 140 kVp; increasing patient size from 10 to 120 kg resulted in an increase in effective photon energy of approximately 4 keV. The x-ray transmission data and effective photon energy data can be used to determine CT image noise and image contrast, respectively, and information on patient size and composition can be used to determine patient doses.
Allen, J.A.
1876-01-01
Having recently had an opportunity (through the kindness of Professor Baird) of studying with some care the magnificent series of skulls of the North American Mammalia belonging to the National Museum (amounting often to eighty or a hundred specimens of a single species), I have been strongly impressed with the different degrees of variability exhibited by the representatives of the species and genera of even the same family. The variation in size, for instance, with latitude, in the Wolves and Foxes is surprisingly great, amounting in some species (as will be shown later) to 25 per cent. of the average size of the species, while in other species of the Ferae it is almost nil. Contrary to the general supposition, the variation in size among representatives of the same species is not always a decrease with the decrease of the latitude of the locality, but is in some cases exactly the reverse, in some species there being a very considerable and indisputable increase southward. This, for instance, is very markedly true of some species of Felis and in Procyon lotor. Consequently, the very generally-received impression that in North America the species of Mammalia diminish in size southward, or with the decrease in the latitude (and altitude) of the locality, requires modification. While such is generally the case, the reverse of this too often occurs, with occasional instances also of a total absence of variation in size with locality, to be considered as forming "the exceptions" necessary to "prove the rule".
Estimating Variances of Horizontal Wind Fluctuations in Stable Conditions
NASA Astrophysics Data System (ADS)
Luhar, Ashok K.
2010-05-01
Information concerning the average wind speed and the variances of lateral and longitudinal wind velocity fluctuations is required by dispersion models to characterise turbulence in the atmospheric boundary layer. When the winds are weak, the scalar average wind speed and the vector average wind speed need to be clearly distinguished and both lateral and longitudinal wind velocity fluctuations assume equal importance in dispersion calculations. We examine commonly-used methods of estimating these variances from wind-speed and wind-direction statistics measured separately, for example, by a cup anemometer and a wind vane, and evaluate the implied relationship between the scalar and vector wind speeds, using measurements taken under low-wind stable conditions. We highlight several inconsistencies inherent in the existing formulations and show that the widely-used assumption that the lateral velocity variance is equal to the longitudinal velocity variance is not necessarily true. We derive improved relations for the two variances, and although data under stable stratification are considered for comparison, our analysis is applicable more generally.
Prevalence and characteristics of teen motherhood in Canada.
Al-Sahab, Ban; Heifetz, Marina; Tamim, Hala; Bohr, Yvonne; Connolly, Jennifer
2012-01-01
The study aims to examine the prevalence and characteristics of adolescent mothers throughout the provinces of Canada. The analysis was based on the Maternity Experience Survey targeting women aged ≥15 years who had singleton live births during 2005/2006 in the Canadian provinces and territories. The main dependent variable in this study was the mother's age at the time of delivery divided into teen mothers (<20 years) and average-aged mothers (≥20 and <35 years). Socio-economic factors, demographic factors and pregnancy related factors were considered for a logistic regression analysis comparing teen mothers to average-aged mothers. Bootstrapping was performed to account for the complex sampling design. The sample size was 6,188 weighted to represent 76,110 Canadian women. The proportion of teen mothers in the MES study was 2.9%, and their average age was 18.1 years (SD = 1.1). As compared to average-aged mothers, teen mothers were more likely to have low socio-economic status, be non-immigrants, have no partner, reside in the Western Prairies, have previously experienced physical or sexual abuse and have preferred to have had their pregnancies later into their adulthood. Despite the above, teen mothers were more likely to attend prenatal classes than average-aged mothers (Odds ratio = 2.54, 95% confidence interval: 1.74-3.71). Intervention studies should aim to raise awareness among teens to prevent teen pregnancies. Since teen mothers are very likely to attend prenatal courses, the focus of these classes should be tailored to the needs of teen mothers. More in depth qualitative studies should aim to understand their individual needs.
Radiography versus computed tomography for displacement assessment in calcaneal fractures.
Ogawa, Brent K; Charlton, Timothy P; Thordarson, David B
2009-10-01
Coronal computed tomography (CT) scans are commonly used in fracture classification systems for calcaneus fractures. However, they may not accurately reflect the amount of fracture displacement. The purpose of this paper was to determine whether lateral radiographs provide superior assessment of the displacement of the posterior facet compared to coronal CT scans. Lateral radiographs of calcaneus fractures were compared with CT coronal images of the posterior facet in 30 displaced intra-articular calcaneus fractures. The average patient age was 39 years old. Using a Picture Archiving and Communication System (PACS), measurements were obtained to quantify the amount of displacement on the lateral radiograph and compared with the amount of depression on corresponding coronal CT scans. On lateral radiographs, the angle of the depressed portion of the posterior facet relative to the undersurface of the calcaneus averaged 28.2 degrees; Bohler's angle averaged 12.7 degrees. These numbers were poorly correlated (r = 0.25). In corresponding CT images from posterior to anterior, the difference in the amount of displacement of the lateral portion of the displaced articular facet versus the nondisplaced medial, constant fragment, was minimal and consistently underestimated the amount of displacement. Underestimation of the amount of depression and rotation of the posterior facet fragment was seen on the coronal CT scan. We attribute this finding to the combined rotation and depression of the posterior facet which may not be measured accurately with the typical semicoronal CT orientation. While sagittal reconstructed images would show this depression better, if they are unavailable we recommend using lateral radiographs to better gauge the amount of fracture displacement.
The Anomalous Drift of Comet ISON (C/2012 S1) due to Sublimating Volatiles near Perihelion
NASA Astrophysics Data System (ADS)
Steckloff, J. K.; Keane, J. V.; Milam, S.; Coulson, I.; Knight, M. M.
2014-12-01
Prior to perihelion passage on 28 November 2013, the observed right ascension (RA) and declination (Dec) coordinates of comet C/2012 S1 (ISON) significantly lagged the predicted JPL (# 53) ephemeris. We show that this "braking effect" is due to a dynamic pressure exerted by sublimating gases on the sunward side of the nucleus [1]. Comet ISON was observed November 23 through November 28 using the SCUBA-2 sub-millimeter camera on the James Clerk Maxwell Telescope (JCMT). Imaging is achieved simultaneously at wavelengths of 850 μm and 450 μm, with RA and Dec determined from the central peak in the coma brightness [2]. When comet ISON was first detected at 850 μm, the 1-mm-sized dust particles were tightly bound to the comet nucleus until at least November 23. Three days later, the dust was less tightly bound, elongated and diffuse, spread out over as much as 120 arc seconds (80,000 km) in the anti-solar direction, suggesting a fragmentation event. We compute the average braking velocity of the nucleus of comet ISON by first measuring the distance between the central RA position and the predicted JPL ephemeris. We then calculate the change in this distance between subsequent observations, and divide this value by the elapsed time between the two observations to yield an average drift velocity of the nucleus over this time interval. We assume that comet ISON, like a number of Jupiter Family Comets visited by spacecraft [3], has low thermal inertia. Thus, the sublimating gases are emitted predominantly on the sunward side of the nucleus. Additionally, we assume that water ice dominates the sublimating gases [4]. We then calculate the pressure on the surface of the nucleus due to the emitted gases using the procedure described in [1]. We match the average drift velocity of the nucleus due to this sublimation pressure with the observed average drift velocity from the JCMT observations, which is sensitive to the size of the body, allowing us to estimate the size of the nucleus (or its fragments) shortly before perihelion. References: [1] Steckloff et al. (2014) Submitted Nature [2] Keane et al. (2014) Submitted Ap. J. [3] Groussin et al. (2013) Icarus 222, 580-594 [4] Combi et al. (2014) Ap. J. 788:L7 (5pp)
Development of a novel image-based program to teach narrow-band imaging.
Dumas, Cedric; Fielding, David; Coles, Timothy; Good, Norm
2016-08-01
Narrow-band imaging (NBI) is a widely available endoscopic imaging technology; however, uptake of the technique could be improved. Teaching new imaging techniques and assessing trainees' performance can be a challenging exercise during a 1-day workshop. To support NBI training, we developed an online training tool (Medimq) to help experts train novices in NBI bronchoscopy that could assess trainees' performance and provide feedback before the close of the 1-day course. The present study determines whether trainees' capacity to identify relevant pathology increases with the proposed interactive testing method. Two groups of 20 and 18 bronchoscopists have attended an NBI course where they did a pretest and post-test before and after the main lecture, and a follow-up test 4 weeks later to measure retention of knowledge. We measured their ability to mark normal and abnormal 'biopsy size' areas on bronchoscopic NBI images for biopsy. These markings were compared with areas marked by experts on the same images. The first group results were used to pilot the test. After modifications, the results of the improved test for group 2 showed trainees improved by 32% (total class average normalized gain) in detecting normal or abnormal areas. On follow-up testing, Group 2 improved by 23%. The overall class average normalized gain of 32% shows our test can be used to improve trainees' competency in analyzing NBI Images. The testing method (and tool) can be used to measure the follow up 4 weeks later. Better follow-up test results would be expected with more frequent practice by trainees after the course. © The Author(s), 2016.
A Phase Field Study of the Effect of Microstructure Grain Size Heterogeneity on Grain Growth
NASA Astrophysics Data System (ADS)
Crist, David J. D.
Recent studies conducted with sharp-interface models suggest a link between the spatial distribution of grain size variance and average grain growth rate. This relationship and its effect on grain growth rate was examined using the diffuse-interface Phase Field Method on a series of microstructures with different degrees of grain size gradation. Results from this work indicate that the average grain growth rate has a positive correlation with the average grain size dispersion for phase field simulations, confirming previous observations. It is also shown that the grain growth rate in microstructures with skewed grain size distributions is better measured through the change in the volume-weighted average grain size than statistical mean grain size. This material is based upon work supported by the National Science Foundation under Grant No. 1334283. The NSF project title is "DMREF: Real Time Control of Grain Growth in Metals" and was awarded by the Civil, Mechanical and Manufacturing Innovation division under the Designing Materials to Revolutionize and Engineer our Future (DMREF) program.
40 CFR 600.510-08 - Calculation of average fuel economy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Regulations for Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and...) Average fuel economy will be calculated to the nearest 0.1 mpg for the classes of automobiles identified...
40 CFR 600.510-86 - Calculation of average fuel economy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Regulations for Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and...) Average fuel economy will be calculated to the nearest 0.1 mpg for the classes of automobiles identified...
40 CFR 600.510-93 - Calculation of average fuel economy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Regulations for Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and...) Average fuel economy will be calculated to the nearest 0.1 mpg for the classes of automobiles identified...
Di Somma, Alberto; Torales, Jorge; Cavallo, Luigi Maria; Pineda, Jose; Solari, Domenico; Gerardi, Rosa Maria; Frio, Federico; Enseñat, Joaquim; Prats-Galino, Alberto; Cappabianca, Paolo
2018-04-20
OBJECTIVE The extended endoscopic endonasal transtuberculum transplanum approach is currently used for the surgical treatment of selected midline anterior skull base lesions. Nevertheless, the possibility of accessing the lateral aspects of the planum sphenoidale could represent a limitation for such an approach. To the authors' knowledge, a clear definition of the eventual anatomical boundaries has not been delineated. Hence, the present study aimed to detail and quantify the maximum amount of bone removal over the planum sphenoidale required via the endonasal pathway to achieve the most lateral extension of such a corridor and to evaluate the relative surgical freedom. METHODS Six human cadaveric heads were dissected at the Laboratory of Surgical NeuroAnatomy of the University of Barcelona. The laboratory rehearsals were run as follows: 1) preliminary predissection CT scans, 2) the endoscopic endonasal transtuberculum transplanum approach (lateral limit: medial optocarotid recess) followed by postdissection CT scans, 3) maximum lateral extension of the transtuberculum transplanum approach followed by postdissection CT scans, and 4) bone removal and surgical freedom analysis (a nonpaired Student t-test). A conventional subfrontal bilateral approach was used to evaluate, from above, the bone removal from the planum sphenoidale and the lateral limit of the endonasal route. RESULTS The endoscopic endonasal transtuberculum transplanum approach was extended at its maximum lateral aspect in the lateral portion of the anterior skull base, removing the bone above the optic prominence, that is, the medial portion of the lesser sphenoid wing, including the anterior clinoid process. As expected, a greater bone removal volume was obtained compared with the approach when bone removal is limited to the medial optocarotid recess (average 533.45 vs 296.07 mm 2 ; p < 0.01). The anteroposterior diameter was an average of 8.1 vs 15.78 mm, and the laterolateral diameter was an average of 18.77 vs 44.54 mm (p < 0.01). The neurovascular contents of this area were exposed up to the insular segment of the middle cerebral artery. The surgical freedom analysis revealed a possible increased lateral maneuverability of instruments inserted in the contralateral nostril compared with a midline target (average 384.11 vs 235.31 mm 2 ; p < 0.05). CONCLUSIONS Bone removal from the medial aspect of the lesser sphenoid wing, including the anterior clinoid process, may increase the exposure and surgical freedom of the extended endoscopic endonasal transtuberculum transplanum approach over the lateral segment of the anterior skull base. Although this study represents a preliminary anatomical investigation, it could be useful to refine the indications and limitations of the endoscopic endonasal corridor for the surgical management of skull base lesions involving the lateral portion of the planum sphenoidale.
Dinstein, Ilan; Haar, Shlomi; Atsmon, Shir; Schtaerman, Hen
2017-01-01
Large controversy exists regarding the potential existence and clinical significance of larger brain volumes in toddlers who later develop autism. Assessing this relationship is important for determining the clinical utility of early head circumference (HC) measures and for assessing the validity of the early overgrowth hypothesis of autism, which suggests that early accelerated brain development may be a hallmark of the disorder. We performed a retrospective comparison of HC, height, and weight measurements between 66 toddlers who were later diagnosed with autism and 66 matched controls. These toddlers represent an unbiased regional sample from a single health service provider in the southern district of Israel. On average, participating toddlers had >8 measurements between birth and the age of two, which enabled us to characterize individual HC, height, and weight development with high precision and fit a negative exponential growth model to the data of each toddler with exceptional accuracy. The analyses revealed that HC sizes and growth rates were not significantly larger in toddlers with autism even when stratifying the autism group based on verbal capabilities at the time of diagnosis. In addition, there were no significant correlations between ADOS scores at the time of diagnosis and HC at any time-point during the first 2 years of life. These negative results add to accumulating evidence, which suggest that brain volume is not necessarily larger in toddlers who develop autism. We believe that conflicting results reported in other studies are due to small sample sizes, use of misleading population norms, changes in the clinical definition of autism over time, and/or inclusion of individuals with syndromic autism. While abnormally large brains may be evident in some individuals with autism and more clearly visible in MRI scans, converging evidence from this and other studies suggests that enlarged HC is not a common etiology of the entire autism population. Early HC measures, therefore, offer very limited clinical utility for assessment of autism risk in the general population.
Architecture and Channel-Belt Clustering in the Fluvial lower Wasatch Formation, Uinta Basin, Utah
NASA Astrophysics Data System (ADS)
Pisel, J. R.; Pyles, D. R.; Bracken, B.; Rosenbaum, C. D.
2013-12-01
The Eocene lower Wasatch Formation of the Uinta Basin contains exceptional outcrops of low net-sand content (27% sand) fluvial strata. This study quantitatively documents the stratigraphy of a 7 km wide by 300 meter thick strike-oriented outcrop in order to develop a quantitative data base that can be used to improve our knowledge of how some fluvial systems evolve over geologic time scales. Data used to document the outcrop are: (1) 550 meters of decimeter to half meter scale resolution stratigraphic columns that document grain size and physical sedimentary structures; (2) detailed photopanels used to document architectural style and lithofacies types in the outcrop; (3) thickness, width, and spatial position for all channel belts in the outcrop, and (4) directional measurements of paleocurrent indicators. Two channel-belt styles are recognized: lateral and downstream accreting channel belts; both of which occur as either single or multi-story. Floodplain strata are well exposed and consist of overbank fines and sand-rich crevasse splay deposits. Key upward and lateral characteristics of the outcrop documented herein are the following. First, the shapes of 243 channels are documented. The average width, thickness and aspect ratios of the channel belts are 110 m, 7 m, and 16:1, respectively. Importantly, the size and shape of channel belts does not change upward through the 300 meter transect. Second, channels are documented to spatially cluster. 9 clusters are documented using a spatial statistic. Key upward patterns in channel belt clustering are a marked change from non-amalgamated isolated channel-belt clusters to amalgamated channel-belt clusters. Critically, stratal surfaces can be correlated from mudstone units within the clusters to time-equivalent floodplain strata adjacent to the cluster demonstrating that clusters are not confined within fluvial valleys. Finally, proportions of floodplain and channel belt elements underlying clusters and channel belts vary with the style of clusters and channel belts laterally and vertically within the outcrop.
NASA Astrophysics Data System (ADS)
Rouholahnejad, E.; Fan, Y.; Kirchner, J. W.; Miralles, D. G.
2017-12-01
Most Earth system models (ESM) average over considerable sub-grid heterogeneity in land surface properties, and overlook subsurface lateral flow. This could potentially bias evapotranspiration (ET) estimates and has implications for future temperature predictions, since overestimations in ET imply greater latent heat fluxes and potential underestimation of dry and warm conditions in the context of climate change. Here we quantify the bias in evaporation estimates that may arise from the fact that ESMs average over considerable heterogeneity in surface properties, and also neglect lateral transfer of water across the heterogeneous landscapes at global scale. We use a Budyko framework to express ET as a function of P and PET to derive simple sub-grid closure relations that quantify how spatial heterogeneity and lateral transfer could affect average ET as seen from the atmosphere. We show that averaging over sub-grid heterogeneity in P and PET, as typical Earth system models do, leads to overestimation of average ET. Our analysis at global scale shows that the effects of sub-grid heterogeneity will be most pronounced in steep mountainous areas where the topographic gradient is high and where P is inversely correlated with PET across the landscape. In addition, we use the Total Water Storage (TWS) anomaly estimates from the Gravity Recovery and Climate Experiment (GRACE) remote sensing product and assimilate it into the Global Land Evaporation Amsterdam Model (GLEAM) to correct for existing free drainage lower boundary condition in GLEAM and quantify whether, and how much, accounting for changes in terrestrial storage can improve the simulation of soil moisture and regional ET fluxes at global scale.
The reliability and stability of visual working memory capacity.
Xu, Z; Adam, K C S; Fang, X; Vogel, E K
2018-04-01
Because of the central role of working memory capacity in cognition, many studies have used short measures of working memory capacity to examine its relationship to other domains. Here, we measured the reliability and stability of visual working memory capacity, measured using a single-probe change detection task. In Experiment 1, the participants (N = 135) completed a large number of trials of a change detection task (540 in total, 180 each of set sizes 4, 6, and 8). With large numbers of both trials and participants, reliability estimates were high (α > .9). We then used an iterative down-sampling procedure to create a look-up table for expected reliability in experiments with small sample sizes. In Experiment 2, the participants (N = 79) completed 31 sessions of single-probe change detection. The first 30 sessions took place over 30 consecutive days, and the last session took place 30 days later. This unprecedented number of sessions allowed us to examine the effects of practice on stability and internal reliability. Even after much practice, individual differences were stable over time (average between-session r = .76).
NASA Astrophysics Data System (ADS)
Pourkhorsandi, H.; Mirnejad, H.
2014-09-01
2D size measurement of chondrules and chondiritic fragments of a meteorite from Lut desert of Iran is conducted. Chondrules exhibit a size range of 55-1800 µm (average 437 µm). Chondiritic fragments show a size range of 46-1220 µm (average 261 µm).
NASA Astrophysics Data System (ADS)
Xi, Kelai; Cao, Yingchang; Jahren, Jens; Zhu, Rukai; Bjørlykke, Knut; Haile, Beyene Girma; Zheng, Lijing; Hellevang, Helge
2015-12-01
The Lower Cretaceous Quantou Formation in the southern Songliao Basin is the typical tight oil sandstone in China. For effective exploration, appraisal and production from such a tight oil sandstone, the diagenesis and reservoir quality must be thoroughly studied first. The tight oil sandstone has been examined by a variety of methods, including core and thin section observation, XRD, SEM, CL, fluorescence, electron probing analysis, fluid inclusion and isotope testing and quantitative determination of reservoir properties. The sandstones are mostly lithic arkoses and feldspathic litharenites with fine to medium grain size and moderate to good sorting. The sandstones are dominated by feldspar, quartz, and volcanic rock fragments showing various stages of disintegration. The reservoir properties are quite poor, with low porosity (average 8.54%) and permeability (average 0.493 mD), small pore-throat radius (average 0.206 μm) and high displacement pressure (mostly higher than 1 MPa). The tight sandstone reservoirs have undergone significant diagenetic alterations such as compaction, feldspar dissolution, quartz cementation, carbonate cementation (mainly ferrocalcite and ankerite) and clay mineral alteration. As to the onset time, the oil emplacement was prior to the carbonate cementation but posterior to the quartz cementation and feldspar dissolution. The smectite to illite reaction and pressure solution at stylolites provide a most important silica sources for quartz cementation. Carbonate cements increase towards interbedded mudstones. Mechanical compaction has played a more important role than cementation in destroying the reservoir quality of the K1q4 sandstone reservoirs. Mixed-layer illite/smectite and illite reduced the porosity and permeability significantly, while chlorite preserved the porosity and permeability since it tends to be oil wet so that later carbonate cementation can be inhibited to some extent. It is likely that the oil emplacement occurred later than the tight rock formation (with the porosity close to 10%). However, thicker sandstone bodies (more than 2 m) constitute potential hydrocarbon reservoirs.
Kamp, Siri-Maria; Brumback, Ty; Donchin, Emanuel
2013-11-01
We examined the degree to which ERP components elicited by items that are isolated from their context, either by their font size ("size isolates") or by their frequency of usage, are correlated with subsequent immediate recall. Study lists contained (a) 15 words including a size isolate, (b) 14 high frequency (HF) words with one low frequency word ("LF isolate"), or (c) 14 LF words with one HF word. We used spatiotemporal PCA to quantify ERP components. We replicated previously reported P300 subsequent memory effects for size isolates and found additional correlations with recall in the novelty P3, a right lateralized positivity, and a left lateralized slow wave that was distinct from the slow wave correlated with recall for nonisolates. LF isolates also showed evidence of a P300 subsequent memory effect and also elicited the left lateralized subsequent memory effect, supporting a role of distinctiveness in word frequency effects in recall. Copyright © 2013 Society for Psychophysiological Research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Haojie; Dhomkar, Siddharth; Roy, Bidisha
2014-10-28
For submonolayer quantum dot (QD) based photonic devices, size and density of QDs are critical parameters, the probing of which requires indirect methods. We report the determination of lateral size distribution of type-II ZnTe/ZnSe stacked submonolayer QDs, based on spectral analysis of the optical signature of Aharanov-Bohm (AB) excitons, complemented by photoluminescence studies, secondary-ion mass spectroscopy, and numerical calculations. Numerical calculations are employed to determine the AB transition magnetic field as a function of the type-II QD radius. The study of four samples grown with different tellurium fluxes shows that the lateral size of QDs increases by just 50%, evenmore » though tellurium concentration increases 25-fold. Detailed spectral analysis of the emission of the AB exciton shows that the QD radii take on only certain values due to vertical correlation and the stacked nature of the QDs.« less
NASA Technical Reports Server (NTRS)
Barlow, Douglas A.; Baird, James K.; Su, Ching-Hua
2003-01-01
More than 75 years ago, von Weimarn summarized his observations of the dependence of the average crystal size on the initial relative concentration supersaturation prevailing in a solution from which crystals were growing. Since then, his empirically derived rules have become part of the lore of crystal growth. The first of these rules asserts that the average crystal size measured at the end of a crystallization increases as the initial value of the relative supersaturation decreases. The second rule states that for a given crystallization time, the average crystal size passes through a maximum as a function of the initial relative supersaturation. Using a theory of nucleation and growth due to Buyevich and Mansurov, we calculate the average crystal size as a function of the initial relative supersaturation. We confirm the von Weimarn rules for the case where the nucleation rate is proportional to the third power or higher of the relative supersaturation.
Dose calculation for electron therapy using an improved LBR method.
Gebreamlak, Wondesen T; Tedeschi, David J; Alkhatib, Hassaan A
2013-07-01
To calculate the percentage depth dose (PDD) of any irregularly shaped electron beam using a modified lateral build-up ratio (LBR) method. Percentage depth dose curves were measured using 6, 9, 12, and 15 MeV electron beam energies for applicator cone sizes of 6 × 6, 10 × 10, 14 × 14, and 20 × 20 cm(2). Circular cutouts for each cone were prepared from 2.0 cm diameter to the maximum possible size for each cone. In addition, three irregular cutouts were prepared. The LBR for each circular cutout was calculated from the measured PDD curve using the open field of the 14 × 14 cm(2) cone as the reference field. Using the LBR values and the radius of the circular cutouts, the corresponding lateral spread parameter [σR(z)] of the electron shower was calculated. Unlike the commonly accepted assumption that σR(z) is independent of cutout size, it is shown that its value increases linearly with circular cutout size (R). Using this characteristic of the lateral spread parameter, the PDD curves of irregularly shaped cutouts were calculated. Finally, the calculated PDD curves were compared with measured PDD curves. In this research, it is shown that the lateral spread parameter σR(z) increases with cutout size. For radii of circular cutout sizes up to the equilibrium range of the electron beam, the increase of σR(z) with the cutout size is linear. The percentage difference of the calculated PDD curve from the measured PDD data for irregularly shaped cutouts was under 1.0% in the region between the surface and therapeutic range of the electron beam. Similar results were obtained for four electron beam energies (6, 9, 12, and 15 MeV).
Darst, Melanie R.; Light, Helen M.
2007-01-01
Floodplain forests of the Apalachicola River, Florida, are drier in composition today (2006) than they were before 1954, and drying is expected to continue for at least the next 50 years. Drier forest composition is probably caused by water-level declines that occurred as a result of physical changes in the main channel after 1954 and decreased flows in spring and summer months since the 1970s. Forest plots sampled from 2004 to 2006 were compared to forests sampled in the late 1970s (1976-79) using a Floodplain Index (FI) based on species dominance weighted by the Floodplain Species Category, a value that represents the tolerance of tree species to inundation and saturation in the floodplain and consequently, the typical historic floodplain habitat for that species. Two types of analyses were used to determine forest changes over time: replicate plot analysis comparing present (2004-06) canopy composition to late 1970s canopy composition at the same locations, and analyses comparing the composition of size classes of trees on plots in late 1970s and in present forests. An example of a size class analysis would be a comparison of the composition of the entire canopy (all trees greater than 7.5 cm (centimeter) diameter at breast height (dbh)) to the composition of the large canopy tree size class (greater than or equal to 25 cm dbh) at one location. The entire canopy, which has a mixture of both young and old trees, is probably indicative of more recent hydrologic conditions than the large canopy, which is assumed to have fewer young trees. Change in forest composition from the pre-1954 period to approximately 2050 was estimated by combining results from three analyses. The composition of pre-1954 forests was represented by the large canopy size class sampled in the late 1970s. The average FI for canopy trees was 3.0 percent drier than the average FI for the large canopy tree size class, indicating that the late 1970s forests were 3.0 percent drier than pre-1954 forests. The change from the late 1970s to the present was based on replicate plot analysis. The composition of 71 replicate plots sampled from 2004 to 2006 averaged 4.4 percent drier than forests sampled in the late 1970s. The potential composition of future forests (2050 or later) was estimated from the composition of the present subcanopy tree size class (less than 7.5 cm and greater than or equal to 2.5 cm dbh), which contains the greatest percentage of young trees and is indicative of recent hydrologic conditions. Subcanopy trees are the driest size class in present forests, with FIs averaging 31.0 percent drier than FIs for all canopy trees. Based on results from all three sets of data, present floodplain forests average 7.4 percent drier in composition than pre-1954 forests and have the potential to become at least 31.0 percent drier in the future. An overall total change in floodplain forests to an average composition 38.4 percent drier than pre-1954 forests is expected within approximately 50 years. The greatest effects of water-level decline have occurred in tupelo-cypress swamps where forest composition has become at least 8.8 percent drier in 2004-06 than in pre-1954 years. This change indicates that a net loss of swamps has already occurred in the Apalachicola River floodplain, and further losses are expected to continue over the next 50 years. Drying of floodplain forests will result in some low bottomland hardwood forests changing in composition to high bottomland hardwood forests. The composition of high bottomland hardwoods will also change, although periodic flooding is still occurring and will continue to limit most of the floodplain to bottomland hardwood species that are adapted to at least short periods of inundation and saturation.
Comparison of male and female foot shape.
Luo, Gangming; Houston, Vern L; Mussman, Martin; Garbarini, Maryanne; Beattie, Aaron C; Thongpop, Chaiya
2009-01-01
Morphological and geometric differences between male and female feet can be the decisive factor of whether well-fitting, functional, and comfortable footwear is available for both men and women. Optical scans, plaster wrap casts, and a set of manual measurements from the right feet of 51 female participants, aged 20 to 59 years (32 +/- 10.2 years), and 39 male participants, aged 22 to 71 years (47.1 +/- 12.1 years), were taken to determine which parameters were the most significant in characterizing pedal geometry and which had the largest difference between male and female feet. Analysis showed that the heel-to-ball length (ball length) of the male participants' feet (181.5 mm) was significantly longer, on average, than that of the female participants' feet (165.0 mm). The width of the male paticipants' feet at the ball, instep, and heel regions, as well as the ball circumference, normalized by the ball length, were all significantly larger on average, than the female test participants' feet. However, toe region, instep, and medial and lateral malleoli heights were larger, on average, for the female participants than for the male. The results show that female feet differ in size and shape from male feet and are not algebraically scaled, smaller versions of male feet, as is often assumed. The study shows that the average male participants' feet are longer than that of the female participants' feet, while the female feet are relatively narrower but higher than those of the male participants.
$sup 137$CCs and $sup 40$K in the flesh of Pacific albacore, 1964--1974
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, D.R.; Folsom, T.R.; Hodge, V.F.
1975-11-01
Concentrations of $sup 137$Cs in the flesh of albacore tuna caught off the California coast during the last 10 yr decreased by a considerably smaller factor than did corresponding values reported for atmospheric fallout. Between 1965 and 1974, average tissue concentrations decreased steadily from 90 to approx 40 pCi/wet kg, which suggests an effective half-time for $sup 137$Cs in the upper layer of the eastern North Pacific of about 1 decade. Values for natural $sup 40$K, which was measured at the same time, averaged 3300 pCi/wet kg. The 1965 mean concentrations of $sup 137$Cs in albacore from four widely separatedmore » fisheries in the Northern Hemisphere agreed within a factor of two, ranging from 50 to 90 pCi/wet kg. In contrast, specimens from South Pacific fishery based at American Samoa averaged only 14 pCi/wet kg. Surface seawater collected around Tutuila Island averaged 0.085 pCi/l. $sup 137$Cs, in good agreement with measurements made a year later over a much wider area of the South Pacific. No large variations in flesh concentrations of $sup 137$Cs or $sup 40$K were observed as a function of tuna size, species, portion of the body sampled, or cooking. Thus, radioanalysis of canned tuna may be an efficient method of following major changes in $sup 137$Cs contamination of upper layers of the world ocean. (auth)« less
Suzuki, T; Uchino, T; Hatta, I; Miyazaki, Y; Kato, S; Sasaki, K; Kagawa, Y
2018-04-29
The aim of this study was to investigate whether the lamellar and lateral structure of intercellular lipid of stratum corneum (SC) can be evaluated from millimeter-sized SC (MSC) by X-ray diffraction. A 12 mm × 12 mm SC sheet from hairless mouse was divided into 16 pieces measuring 3 mm × 3 mm square. From another sheet, 4 pieces of ultramillimeter-sized SC (USC:1.5 mm × 1.5 mm square) were prepared. Small and wide-angle X-ray diffraction (SAXD and WAXD) measurements were performed on each piece. For MSC and USC, changes in the lamellar and lateral structure after the application of d-limonene were measured. The intensity of SAXD peaks due to the lamellar phase of long periodicity phase (LPP) and WAXD peaks due to the lateral hydrocarbon chain-packing structures varied in MSC and USC pieces, although over the 12 mm × 12 mm SC sheet. These results indicated that the intercellular lipid components and their proportion appeared nearly uniform. Application of d-limonene on MSC and USC piece with strong peaks in SAXD and the WAXD resulted in the disappearance of peaks due to the lamellar phase of LPP and decrease in peak intensity for the lateral hydrocarbon chain-packing structures. These changes are consistent with normal-sized sample results. We found that the selection of a sample piece with strong diffraction peaks due to the lamellar and lateral structure enabled evaluation of the SC structure in small-sized samples by X-ray diffraction. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Study of Colloidal Gold Synthesis Using Turkevich Method
NASA Astrophysics Data System (ADS)
Rohiman, Asep; Anshori, Isa; Surawijaya, Akhmadi; Idris, Irman
2011-12-01
The synthesis of colloidal gold or Au-nanoparticles (Au-NPs) by reduction of chloroauric acid (HAuCl4) with sodium citrate was done using Turkevich method. We prepare HAuCl4 solution by dissolving gold wires (99.99%) into aqua regia solution. To initiate the Au-NPs synthesis 0.17 ml of 1 % chloroauric acid solution was heated to the boiling point and then 10 ml of 1 % sodium citrate was added to the boiling solution with a constant stirring in order to maintain a homogenous solution. A color of faint gray was observed in the solution approximately one minute and in a period of 2-3 minutes later, it further darkened to deep wine and red color. It showed that the gold solution has reduced to Au-NPs. The effect of process temperature on the size of Au-NPs prepared by sodium citrate reduction has also been investigated. With increasing temperature of Au-NPs synthesis, smaller-size Au-NPs were obtained. The higher temperatures shorten the time needed to achieve activation energy for reduction process. The resulting Au-NPs has been characterized by scanning Electron Microscope (SEM), showing the size of Au-NPs average diameter is ˜20-27 nm. The resulting colloidal gold will be used as catalyst for Si nanowires growth using VLS method.
Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement.
Blagg, Stuart E; Don, Angus S; Robertson, Peter A
2009-06-01
Anatomic study of C1 osteology using computerized tomography. To define the anatomy of the C1 lateral mass and make recommendations for optimal entry point and screw placement at C1. C1 lateral mass screw fixation is a reliable biomechanical technique that gives equivalent stability to that of Magerl transarticular screw fixation combined with posterior wiring for C1-C2 fusion. Use of a lateral mass screw allows alternative stabilization constructs to the transarticular technique when C2 vertebral artery anatomy is unfavorable. Because the vertebral artery travels lateral to the lateral mass, then crosses medially over the C1 neural arch, it is at risk during instrumentation. Medially, the cord and canal contents are at risk. While the anatomy of the C1 vertebra and lateral mass is well known, specific definition of ideal entry points, screw pathway direction, and dimensions of screws requires further clarification to enable a clinically safe surgical technique. Fifty consecutive patients underwent computerized tomography scans of their cervical spine. Using calibrated scans, measurements were taken to give the average dimensions of the C1 vertebra with a view for insertion of lateral mass screws beneath the posterior arch. The range of anatomic dimensions was examined to assess risk of vertebral artery damage in this population. The average length of screw within the lateral mass is 17.9 mm with 21.5 mm of screw posterior to the lateral mass, necessary to allow rod placement posteriorly. The safest entry point was directly beneath the medial edge of the posterior arch/lamina where it joins the lateral mass. The ideal direction of screw angulation in the sagittal plane was parallel to the posterior arch of C1. In the medial lateral plane, direct anterior placement could be used, but the lateral mass will tolerate 20 degrees of medial angulation from this starting point. The average distance between the vertebral artery foramen laterally and the screw pathway was 8.8 mm using these landmarks, and 5.8 mm from the medial aspect of the lateral mass. The range of anatomic variation was such that 9 lateral masses had a vertebral artery foramen to screw distance of only 3 mm. The vertebral artery was not at risk when these anatomic landmarks were used. C1 lateral mass screws are best placed beneath the posterior arch, parallel with the arch in the sagittal plan. The entry point is the medial border of the neural arch at its junction with the lateral mass. Straight ahead screw direction is safe in the axial plane, but up to 20 degrees of medial angulation will increase the safety margin from the vertebral artery foramen, and this technique avoids vertebral artery damage and optimizes lateral mass screw purchase. We suggest that this is the preferred method of entry into the lateral mass of C1.
40 CFR 600.501-86 - General applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's... subpart are applicable to 1986 and later model year gasoline-fueled and diesel automobiles. (b)(1...
Nishizuka, Takanobu; Iwatsuki, Katsuyuki; Kurimoto, Shigeru; Yamamoto, Michiro; Onishi, Tetsuro; Hirata, Hitoshi
2018-06-01
The aim of our study was to compare the responsiveness of the Hand10 questionnaire and the Pain visual analogue scale (VAS) for the assessment of lateral epicondylitis. The standardized response mean and effect size were used as indicators of responsiveness, measured at baseline and after 6 months of treatment. Among the 54 patients enrolled, 28 were treated using a forearm band, compress and stretching, with the other 26 patients treated using compress and stretching. The standardized response mean and the effect size were 1.18 and 1.38, respectively, of the Hand10 and 1.39 and 1.75, respectively, for the Pain VAS. The responsiveness of both tests was considered to be large, based on Cohen's classification of effect size, supporting the use of the Hand10 questionnaire to assess treatment outcomes for lateral epicondylitis.
James, T Dobbins; McAdams, H Page; Song, Jae-Woo; Li, Christina M; Godfrey, Devon J; DeLong, David M; Paik, Sang-Hyun; Martinez-Jimenez, Santiago
2008-06-01
The authors report interim clinical results from an ongoing NIH-sponsored trial to evaluate digital chest tomosynthesis for improving detectability of small lung nodules. Twenty-one patients undergoing computed tomography (CT) to follow up lung nodules were consented and enrolled to receive an additional digital PA chest radiograph and digital tomosynthesis exam. Tomosynthesis was performed with a commercial CsI/a-Si flat-panel detector and a custom-built tube mover. Seventy-one images were acquired in 11 s, reconstructed with the matrix inversion tomosynthesis algorithm at 5-mm plane spacing, and then averaged (seven planes) to reduce noise and low-contrast artifacts. Total exposure for tomosynthesis imaging was equivalent to that of 11 digital PA radiographs (comparable to a typical screen-film lateral radiograph or two digital lateral radiographs). CT scans (1.25-mm section thickness) were reviewed to confirm presence and location of nodules. Three chest radiologists independently reviewed tomosynthesis images and PA chest radiographs to confirm visualization of nodules identified by CT. Nodules were scored as: definitely visible, uncertain, or not visible. 175 nodules (diameter range 3.5-25.5 mm) were seen by CT and grouped according to size: < 5, 5-10, and > 10 mm. When considering as true positives only nodules that were scored definitely visible, sensitivities for all nodules by tomosynthesis and PA radiography were 70% (+/- 5%) and 22% (+/- 4%), respectively, (p < 0.0001). Digital tomosynthesis showed significantly improved sensitivity of detection of known small lung nodules in all three size groups, when compared to PA chest radiography.
Curtis L. VanderSchaaf; Harold E. Burkhart
2010-01-01
Maximum size-density relationships (MSDR) provide natural resource managers useful information about the relationship between tree density and average tree size. Obtaining a valid estimate of how maximum tree density changes as average tree size changes is necessary to accurately describe these relationships. This paper examines three methods to estimate the slope of...
Sample Size Bias in Judgments of Perceptual Averages
ERIC Educational Resources Information Center
Price, Paul C.; Kimura, Nicole M.; Smith, Andrew R.; Marshall, Lindsay D.
2014-01-01
Previous research has shown that people exhibit a sample size bias when judging the average of a set of stimuli on a single dimension. The more stimuli there are in the set, the greater people judge the average to be. This effect has been demonstrated reliably for judgments of the average likelihood that groups of people will experience negative,…
Arthroscopic repair of chronic lateral ankle instability.
Corte-Real, Nuno M; Moreira, Rodrigo M
2009-03-01
The current "gold standard'' for treatment of chronic lateral ankle instability is the Broström-Gould procedure. Most authors recommend this type of operation even after an arthroscopic inspection of the joint. We review our results with an arthroscopic method of lateral ankle ligament repair. A method of arthroscopic lateral ligament repair with an anchor placed in the fibula is described. We used this technique on 31 consecutive patients (28 were available for followup). Twenty-one patients had work or traffic accidents, four suffered casual falls. and three had sport-related lesions. The patients were evaluated after 24.5 month average followup. The average postoperative AOFAS score was 85.3 (82.3 in the workers-compensation group and 94.4 in the others) and average satisfaction was 3.8 (3.5 to workers-compensation and 4.6 for the others). Complications occurred in nine patients (29%), but only three cases had ongoing problems. We had two recurrences (another sprain without instability on the stress radiograph). Three patients had some wound healing problems and three had injuries of the superficial peroneal nerve, one of which is persistent. One patient developed a deep venous thrombosis postoperatively. With this method, we achieved good clinical results. We had several complications but most of them were minor. It was a simple procedure with less morbidity to most patients. We believe it produced an anatomical repair of the lateral ligament with clinical and functional results similar to other techniques.
On the Importance of Cycle Minimum in Sunspot Cycle Prediction
NASA Technical Reports Server (NTRS)
Wilson, Robert M.; Hathaway, David H.; Reichmann, Edwin J.
1996-01-01
The characteristics of the minima between sunspot cycles are found to provide important information for predicting the amplitude and timing of the following cycle. For example, the time of the occurrence of sunspot minimum sets the length of the previous cycle, which is correlated by the amplitude-period effect to the amplitude of the next cycle, with cycles of shorter (longer) than average length usually being followed by cycles of larger (smaller) than average size (true for 16 of 21 sunspot cycles). Likewise, the size of the minimum at cycle onset is correlated with the size of the cycle's maximum amplitude, with cycles of larger (smaller) than average size minima usually being associated with larger (smaller) than average size maxima (true for 16 of 22 sunspot cycles). Also, it was found that the size of the previous cycle's minimum and maximum relates to the size of the following cycle's minimum and maximum with an even-odd cycle number dependency. The latter effect suggests that cycle 23 will have a minimum and maximum amplitude probably larger than average in size (in particular, minimum smoothed sunspot number Rm = 12.3 +/- 7.5 and maximum smoothed sunspot number RM = 198.8 +/- 36.5, at the 95-percent level of confidence), further suggesting (by the Waldmeier effect) that it will have a faster than average rise to maximum (fast-rising cycles have ascent durations of about 41 +/- 7 months). Thus, if, as expected, onset for cycle 23 will be December 1996 +/- 3 months, based on smoothed sunspot number, then the length of cycle 22 will be about 123 +/- 3 months, inferring that it is a short-period cycle and that cycle 23 maximum amplitude probably will be larger than average in size (from the amplitude-period effect), having an RM of about 133 +/- 39 (based on the usual +/- 30 percent spread that has been seen between observed and predicted values), with maximum amplitude occurrence likely sometime between July 1999 and October 2000.
Lateral dimension-dependent antibacterial activity of graphene oxide sheets.
Liu, Shaobin; Hu, Ming; Zeng, Tingying Helen; Wu, Ran; Jiang, Rongrong; Wei, Jun; Wang, Liang; Kong, Jing; Chen, Yuan
2012-08-21
Graphene oxide (GO) is a promising precursor to produce graphene-family nanomaterials for various applications. Their potential health and environmental impacts need a good understanding of their cellular interactions. Many factors may influence their biological interactions with cells, and the lateral dimension of GO sheets is one of the most relevant material properties. In this study, a model bacterium, Escherichia coli ( E. coli ), was used to evaluate the antibacterial activity of well-dispersed GO sheets, whose lateral size differs by more than 100 times. Our results show that the antibacterial activity of GO sheets toward E. coli cells is lateral size dependent. Larger GO sheets show stronger antibacterial activity than do smaller ones, and they have different time- and concentration-dependent antibacterial activities. Large GO sheets lead to most cell loss after 1 h incubation, and their concentration strongly influences antibacterial activity at relative low concentration (<10 μg/mL). In contrast, when incubating with small GO sheets up to 4 h, the inactivation rate of E. coli cells continues increasing. The increase of small GO sheet concentration also results in persistent increases in their antibacterial activity. In this study, GO sheets with different lateral sizes are all well dispersed, and their oxidation capacity toward glutathione is similar, consistent with X-ray photoelectron spectroscopy and ultraviolet-visible absorption spectroscopy results. This suggests the lateral size-dependent antibacterial activity of GO sheets is caused by neither their aggregation states, nor oxidation capacity. Atomic force microscope analysis of GO sheets and cells shows that GO sheets interact strongly with cells. Large GO sheets more easily cover cells, and cells cannot proliferate once fully covered, resulting in the cell viability loss observed in the followed colony counting test. In contrast, small GO sheets adhere to the bacterial surfaces, which cannot effectively isolate cells from environment. This study highlights the importance of tailoring the lateral dimension of GO sheets to optimize the application potential with minimal risks for environmental health and safety.
Size and emotion averaging: costs of dividing attention after all.
Brand, John; Oriet, Chris; Tottenham, Laurie Sykes
2012-03-01
Perceptual averaging is a process by which sets of similar items are represented by summary statistics such as their average size, luminance, or orientation. Researchers have argued that this process is automatic, able to be carried out without interference from concurrent processing. Here, we challenge this conclusion and demonstrate a reliable cost of computing the mean size of circles distinguished by colour (Experiments 1 and 2) and the mean emotionality of faces distinguished by sex (Experiment 3). We also test the viability of two strategies that could have allowed observers to guess the correct response without computing the average size or emotionality of both sets concurrently. We conclude that although two means can be computed concurrently, doing so incurs a cost of dividing attention.
Genome size analyses of Pucciniales reveal the largest fungal genomes.
Tavares, Sílvia; Ramos, Ana Paula; Pires, Ana Sofia; Azinheira, Helena G; Caldeirinha, Patrícia; Link, Tobias; Abranches, Rita; Silva, Maria do Céu; Voegele, Ralf T; Loureiro, João; Talhinhas, Pedro
2014-01-01
Rust fungi (Basidiomycota, Pucciniales) are biotrophic plant pathogens which exhibit diverse complexities in their life cycles and host ranges. The completion of genome sequencing of a few rust fungi has revealed the occurrence of large genomes. Sequencing efforts for other rust fungi have been hampered by uncertainty concerning their genome sizes. Flow cytometry was recently applied to estimate the genome size of a few rust fungi, and confirmed the occurrence of large genomes in this order (averaging 225.3 Mbp, while the average for Basidiomycota was 49.9 Mbp and was 37.7 Mbp for all fungi). In this work, we have used an innovative and simple approach to simultaneously isolate nuclei from the rust and its host plant in order to estimate the genome size of 30 rust species by flow cytometry. Genome sizes varied over 10-fold, from 70 to 893 Mbp, with an average genome size value of 380.2 Mbp. Compared to the genome sizes of over 1800 fungi, Gymnosporangium confusum possesses the largest fungal genome ever reported (893.2 Mbp). Moreover, even the smallest rust genome determined in this study is larger than the vast majority of fungal genomes (94%). The average genome size of the Pucciniales is now of 305.5 Mbp, while the average Basidiomycota genome size has shifted to 70.4 Mbp and the average for all fungi reached 44.2 Mbp. Despite the fact that no correlation could be drawn between the genome sizes, the phylogenomics or the life cycle of rust fungi, it is interesting to note that rusts with Fabaceae hosts present genomes clearly larger than those with Poaceae hosts. Although this study comprises only a small fraction of the more than 7000 rust species described, it seems already evident that the Pucciniales represent a group where genome size expansion could be a common characteristic. This is in sharp contrast to sister taxa, placing this order in a relevant position in fungal genomics research.
Genome size analyses of Pucciniales reveal the largest fungal genomes
Tavares, Sílvia; Ramos, Ana Paula; Pires, Ana Sofia; Azinheira, Helena G.; Caldeirinha, Patrícia; Link, Tobias; Abranches, Rita; Silva, Maria do Céu; Voegele, Ralf T.; Loureiro, João; Talhinhas, Pedro
2014-01-01
Rust fungi (Basidiomycota, Pucciniales) are biotrophic plant pathogens which exhibit diverse complexities in their life cycles and host ranges. The completion of genome sequencing of a few rust fungi has revealed the occurrence of large genomes. Sequencing efforts for other rust fungi have been hampered by uncertainty concerning their genome sizes. Flow cytometry was recently applied to estimate the genome size of a few rust fungi, and confirmed the occurrence of large genomes in this order (averaging 225.3 Mbp, while the average for Basidiomycota was 49.9 Mbp and was 37.7 Mbp for all fungi). In this work, we have used an innovative and simple approach to simultaneously isolate nuclei from the rust and its host plant in order to estimate the genome size of 30 rust species by flow cytometry. Genome sizes varied over 10-fold, from 70 to 893 Mbp, with an average genome size value of 380.2 Mbp. Compared to the genome sizes of over 1800 fungi, Gymnosporangium confusum possesses the largest fungal genome ever reported (893.2 Mbp). Moreover, even the smallest rust genome determined in this study is larger than the vast majority of fungal genomes (94%). The average genome size of the Pucciniales is now of 305.5 Mbp, while the average Basidiomycota genome size has shifted to 70.4 Mbp and the average for all fungi reached 44.2 Mbp. Despite the fact that no correlation could be drawn between the genome sizes, the phylogenomics or the life cycle of rust fungi, it is interesting to note that rusts with Fabaceae hosts present genomes clearly larger than those with Poaceae hosts. Although this study comprises only a small fraction of the more than 7000 rust species described, it seems already evident that the Pucciniales represent a group where genome size expansion could be a common characteristic. This is in sharp contrast to sister taxa, placing this order in a relevant position in fungal genomics research. PMID:25206357
40 CFR 600.501-93 - General applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's... subpart are applicable to 1993 and later model year passenger automobiles and light trucks, and to the...
40 CFR 600.501-12 - General applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's... subpart are applicable to 2012 and later model year passenger automobiles and light trucks and to the...
Dittmar, Helga; Howard, Sarah
2004-12-01
Previous experimental research indicates that the use of average-size women models in advertising prevents the well-documented negative effect of thin models on women's body image, while such adverts are perceived as equally effective (Halliwell & Dittmar, 2004). The current study extends this work by: (a) seeking to replicate the finding of no difference in advertising effectiveness between average-size and thin models (b) examining level of ideal-body internalization as an individual, internal factor that moderates women's vulnerability to thin media models, in the context of (c) comparing women in professions that differ radically in their focus on, and promotion of, the sociocultural ideal of thinness for women--employees in fashion advertising (n = 75) and teachers in secondary schools (n = 75). Adverts showing thin, average-size and no models were perceived as equally effective. High internalizers in both groups of women felt worse about their body image after exposure to thin models compared to other images. Profession affected responses to average-size models. Teachers reported significantly less body-focused anxiety after seeing average-size models compared to no models, while there was no difference for fashion advertisers. This suggests that women in professional environments with less focus on appearance-related ideals can experience increased body-esteem when exposed to average-size models, whereas women in appearance-focused professions report no such relief.
Nadkarni, Tanvi N; Andreoli, Matthew J; Nair, Veena A; Yin, Peng; Young, Brittany M; Kundu, Bornali; Pankratz, Joshua; Radtke, Andrew; Holdsworth, Ryan; Kuo, John S; Field, Aaron S; Baskaya, Mustafa K; Moritz, Chad H; Meyerand, M Elizabeth; Prabhakaran, Vivek
2015-01-01
Functional magnetic resonance imaging (fMRI) is a non-invasive pre-surgical tool used to assess localization and lateralization of language function in brain tumor and vascular lesion patients in order to guide neurosurgeons as they devise a surgical approach to treat these lesions. We investigated the effect of varying the statistical thresholds as well as the type of language tasks on functional activation patterns and language lateralization. We hypothesized that language lateralization indices (LIs) would be threshold- and task-dependent. Imaging data were collected from brain tumor patients (n = 67, average age 48 years) and vascular lesion patients (n = 25, average age 43 years) who received pre-operative fMRI scanning. Both patient groups performed expressive (antonym and/or letter-word generation) and receptive (tumor patients performed text-reading; vascular lesion patients performed text-listening) language tasks. A control group (n = 25, average age 45 years) performed the letter-word generation task. Brain tumor patients showed left-lateralization during the antonym-word generation and text-reading tasks at high threshold values and bilateral activation during the letter-word generation task, irrespective of the threshold values. Vascular lesion patients showed left-lateralization during the antonym and letter-word generation, and text-listening tasks at high threshold values. Our results suggest that the type of task and the applied statistical threshold influence LI and that the threshold effects on LI may be task-specific. Thus identifying critical functional regions and computing LIs should be conducted on an individual subject basis, using a continuum of threshold values with different tasks to provide the most accurate information for surgical planning to minimize post-operative language deficits.
Carlisle, John A.; Auciello, Orlando; Birrell, James
2006-10-31
An ultrananocrystalline diamond (UNCD) having an average grain size between 3 and 5 nanometers (nm) with not more than about 8% by volume diamond having an average grain size larger than 10 nm. A method of manufacturing UNCD film is also disclosed in which a vapor of acetylene and hydrogen in an inert gas other than He wherein the volume ratio of acetylene to hydrogen is greater than 0.35 and less than 0.85, with the balance being an inert gas, is subjected to a suitable amount of energy to fragment at least some of the acetylene to form a UNCD film having an average grain size of 3 to 5 nm with not more than about 8% by volume diamond having an average grain size larger than 10 nm.
LiDAR and Field Observations of Earthquake Slip Distribution for the central San Jacinto fault
NASA Astrophysics Data System (ADS)
Salisbury, J. B.; Rockwell, T. K.; Middleton, T.; Hudnut, K. W.
2010-12-01
We mapped the tectonic geomorphology of 80 km of the Clark strand of the San Jacinto fault to determine slip per event for the past several surface ruptures. From the southeastern end of Clark Valley (east of Borrego Springs) northwest to the mouth of Blackburn Canyon (near Hemet), we identify 203 offset geomorphic features from which we make over 560 measurements on channel margins, channel thalwegs, ridge noses, and bar crests using filtered B4 LiDAR imagery, aerial photography, and field observations. Displacement estimates show that the most recent large event (MRE) produced an average of 2.5-2.9 m of right-lateral slip, with maximum slip of 3.5 to 4 m at Anza. Double-event offsets for the same 80 km section average ~5.5 m of right-lateral slip. Maximum values near Anza are estimated to be close to 3 m for the penultimate event, suggesting that the penultimate event was similar in size to the MRE. The third event is also similar in size, with cumulative displacement of 9-10 m through Anza for the past three events. Magnitude estimates for the MRE range from Mw 7.2 to Mw 7.5, depending on how far north the rupture continued. Historically, no earthquakes reported along the Clark fault are large enough to have produced the offset geomorphology we observe. However, recent paleoseismic work at Hog Lake dates the most recent surface rupture event at ca. 1790, potentially placing this event in the historic period. A poorly located, large earthquake occurred on November 22, 1800, and is reported to have caused extensive damage (MMI VII) at the San Diego and San Juan Capistrano missions. We infer slightly lower intensity values for the two missions (MMI VI-VII instead of VII) and relocate this event on the Clark fault based on dating of the MRE at Hog Lake. We also recognize the occurrence of a younger offset along ~15-20 km of the fault in Blackburn Canyon, apparently due to lower slip in that area in the November 22, 1800 event. With average displacement of ~1.25 m, we attribute these offsets to the M6.9 April 21, 1918 event. These data argue that much or all of the Clark fault, and possibly also the Casa Loma fault fail together in large earthquakes, but that shorter sections may also fail in smaller events.
Sanz, Crickette M; Morgan, David B; Hopkins, William D
2016-11-01
The nearly universal right hand preference manifested by human populations is one of the most pronounced manifestations of population-level lateralization. Morphological and archeological evidence indicate that this behavioral specialization may have emerged among our hominin ancestors. Whether population-level behavioral asymmetries are evident in non-human animals remains a topic of considerable scientific debate, with the most consistent evidence of population-level trends emerging from studies of chimpanzees (Pan troglodytes). However, previous studies of population-level lateralization in wild apes have relied upon data sets pooled across populations to reach adequate sample sizes. Our aim was to test for population-level handedness within a single wild chimpanzee population, and also to determine if performance asymmetries were associated with handedness. To address these questions, we coded handedness and duration of fishing probe insertions from remote video footage of chimpanzee visitation to termite nests (totaling 119 hr) in the Goualougo Triangle, Republic of Congo. Similar to reports from other populations, chimpanzees in the Goualougo Triangle showed robust individual hand preferences for termite fishing. There were 46 right-handed, 39 left-handed, and 4 ambiguously-handed individuals. Though we did not detect an overall significant population-level handedness (t(88) = 0.83, n.s.) in this study, males showed a greater right hand preference than females. Further, we found that average dipping latencies were significantly faster for right- compared to left-handed chimpanzees. Possible explanations and evolutionary implications of taxa- and task-specific patterns of population-level laterality are discussed. Am. J. Primatol. 78:1190-1200, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Plant Proteins Are Smaller Because They Are Encoded by Fewer Exons than Animal Proteins.
Ramírez-Sánchez, Obed; Pérez-Rodríguez, Paulino; Delaye, Luis; Tiessen, Axel
2016-12-01
Protein size is an important biochemical feature since longer proteins can harbor more domains and therefore can display more biological functionalities than shorter proteins. We found remarkable differences in protein length, exon structure, and domain count among different phylogenetic lineages. While eukaryotic proteins have an average size of 472 amino acid residues (aa), average protein sizes in plant genomes are smaller than those of animals and fungi. Proteins unique to plants are ∼81aa shorter than plant proteins conserved among other eukaryotic lineages. The smaller average size of plant proteins could neither be explained by endosymbiosis nor subcellular compartmentation nor exon size, but rather due to exon number. Metazoan proteins are encoded on average by ∼10 exons of small size [∼176 nucleotides (nt)]. Streptophyta have on average only ∼5.7 exons of medium size (∼230nt). Multicellular species code for large proteins by increasing the exon number, while most unicellular organisms employ rather larger exons (>400nt). Among subcellular compartments, membrane proteins are the largest (∼520aa), whereas the smallest proteins correspond to the gene ontology group of ribosome (∼240aa). Plant genes are encoded by half the number of exons and also contain fewer domains than animal proteins on average. Interestingly, endosymbiotic proteins that migrated to the plant nucleus became larger than their cyanobacterial orthologs. We thus conclude that plants have proteins larger than bacteria but smaller than animals or fungi. Compared to the average of eukaryotic species, plants have ∼34% more but ∼20% smaller proteins. This suggests that photosynthetic organisms are unique and deserve therefore special attention with regard to the evolutionary forces acting on their genomes and proteomes. Copyright © 2016 The Authors. Production and hosting by Elsevier Ltd.. All rights reserved.
Is radiographic measurement of bony landmarks reliable for lateral meniscal sizing?
Yoon, Jung-Ro; Kim, Taik-Seon; Lim, Hong-Chul; Lim, Hyung-Tae; Yang, Jae-Hyuk
2011-03-01
The accuracy of meniscal measurement methods is still in debate. The authors' protocol for radiologic measurements will provide reproducible bony landmarks, and this measurement method of the lateral tibial plateau will correlate with the actual anatomic value. Controlled laboratory study. Twenty-five samples of fresh lateral meniscus with attached proximal tibia were obtained during total knee arthroplasty. Each sample was obtained without damage to the meniscus and bony attachment sites. The inclusion criterion was mild to moderate osteoarthritis in patients with mechanical axis deviation of less than 15°. Knees with lateral compartment osteoarthritic change or injured or degenerated menisci were excluded. For the lateral tibial plateau length measurements, the radiographic beam was angled 10° caudally at neutral rotation, which allowed differentiation of the lateral plateau cortical margins from the medial plateau. The transition points were identified and used for length measurement. The values of length were then compared with the conventional Pollard method and the anatomic values. The width measurement was done according to Pollard's protocol. For each knee, the percentage deviation from the anatomic dimension was recorded. Intraobserver error and interobserver error were calculated. The deviation of the authors' radiographic length measurements from anatomic dimensions was 1.4 ± 1.1 mm. The deviation of Pollard's radiographic length measurements was 4.1 ± 2.0 mm. With respect to accuracy-which represents the frequency of measurements that fall within 10% of measurements-the accuracy of authors' length was 98%, whereas for Pollard's method it was 40%. There was a good correlation between anatomic meniscal dimensions and each radiologic plateau dimensions for lateral meniscal width (R(2) = .790) and the authors' lateral meniscal length (R(2) = .823) and fair correlation for Pollard's lateral meniscal length (R(2) = .660). The reliability of each radiologic measurement showed good reliability (intraclass correlation coefficients, .823 to .973). The authors tried to determine the best-fit equation for predicting meniscal size from Pollard's method of bone size, as follows: anatomic length = 0.52 × plateau length (according to Pollard's method) + 5.2, not as Pollard suggested (0.7 × Pollard's plateau length). Based on this equation-namely, the modified Pollard method-the percentage difference decreased, and the accuracy increased to 92%. Lateral meniscal length dimension can be accurately predicted from the authors' radiographic tibial plateau measurements. This study may provide valuable information in preoperative sizing of lateral meniscus in meniscal allograft transplantation.
Size and Location of Defects at the Coupling Interface Affect Lithotripter Performance
Li, Guangyan; Williams, James C.; Pishchalnikov, Yuri A.; Liu, Ziyue; McAteer, James A.
2012-01-01
OBJECTIVE To determine how the size and location of coupling defects caught between the therapy head of a lithotripter and the skin of a surrogate patient (acoustic window of a test chamber) affect the features of shock waves responsible for stone breakage. METHODS Model defects were placed in the coupling gel between the therapy head of a Dornier Compact-S electromagnetic lithotripter and the Mylar window of a water-filled coupling test system. A fiber-optic hydrophone was used to measure acoustic pressures and map the lateral dimensions of the focal zone of the lithotripter. The effect of coupling conditions on stone breakage was assessed using Gypsum model stones. RESULTS Stone breakage decreased in proportion to the area of the coupling defect; a centrally located defect blocking only 18% of the transmission area reduced stone breakage by an average of almost 30%. The effect on stone breakage was greater for defects located on-axis and decreased as the defect was moved laterally; an 18% defect located near the periphery of the coupling window (2.0 cm off-axis) reduced stone breakage by only ~15% compared to when coupling was completely unobstructed. Defects centered within the coupling window acted to narrow the focal width of the lithotripter; an 8.2% defect reduced the focal width ~30% compared to no obstruction (4.4 mm versus 6.5 mm). Coupling defects located slightly off center disrupted the symmetry of the acoustic field; an 18% defect positioned 1.0 cm off-axis shifted the focus of maximum positive pressure ~1.0 mm laterally. Defects on and off-axis imposed a significant reduction in the energy density of shock waves across the focal zone. CONCLUSIONS In addition to blocking the transmission of shock wave energy, coupling defects also disrupt the properties of shock waves that play a role in stone breakage, including the focal width of the lithotripter and the symmetry of the acoustic field; the effect is dependent on the size and location of defects, with defects near the center of the coupling window having the greatest effect. These data emphasize the importance of eliminating air pockets from the coupling interface, particularly defects located near the center of the coupling window. PMID:22938566
Perceptual Averaging in Individuals with Autism Spectrum Disorder.
Corbett, Jennifer E; Venuti, Paola; Melcher, David
2016-01-01
There is mounting evidence that observers rely on statistical summaries of visual information to maintain stable and coherent perception. Sensitivity to the mean (or other prototypical value) of a visual feature (e.g., mean size) appears to be a pervasive process in human visual perception. Previous studies in individuals diagnosed with Autism Spectrum Disorder (ASD) have uncovered characteristic patterns of visual processing that suggest they may rely more on enhanced local representations of individual objects instead of computing such perceptual averages. To further explore the fundamental nature of abstract statistical representation in visual perception, we investigated perceptual averaging of mean size in a group of 12 high-functioning individuals diagnosed with ASD using simplified versions of two identification and adaptation tasks that elicited characteristic perceptual averaging effects in a control group of neurotypical participants. In Experiment 1, participants performed with above chance accuracy in recalling the mean size of a set of circles ( mean task ) despite poor accuracy in recalling individual circle sizes ( member task ). In Experiment 2, their judgments of single circle size were biased by mean size adaptation. Overall, these results suggest that individuals with ASD perceptually average information about sets of objects in the surrounding environment. Our results underscore the fundamental nature of perceptual averaging in vision, and further our understanding of how autistic individuals make sense of the external environment.
Hojat, Mohammadreza; Mangione, Salvatore; Nasca, Thomas J; Gonnella, Joseph S; Magee, Mike
2005-12-01
The authors designed the present study to examine the association between individuals' scores on the Jefferson Scale of Physician Empathy (JSPE; M. Hojat, J. S. Gonnella, S. Mangione, T. J. Nasca, & M. Magee, 2003; M. Hojat, J. S. Gonnella, T. J. Nasca, S. Mangione, M. Vergare, & M. Magee, 2002; M. Hojat, S. Mangione, T. J. Nasca, M. J. M. Cohen, J. S. Gonnella, J. B. Erdmann, J. J. Veloski, & M. Magee, 2001), a self-report empathy scale, during medical school and ratings of their empathic behavior made by directors of their residency training programs 3 years later. Participants were 106 physicians. The authors examined the relationships between scores on the JSPE (with 20 Likert-type items) at the beginning of the students' 3rd year of medical school and ratings of their empathic behavior made by directors of their residency training programs. Top scorers on the JSPE in medical school, compared to Bottom scorers, obtained a significantly higher average rating of empathic behavior in residency 3 years later (p < .05, effect size = 0.50). The findings support the long-term predictive validity of the self-report empathy scale, JSPE, despite different methods of evaluations (self-report and supervisors' ratings) and despite a time interval between evaluations (3 years). Because empathy is relevant to prosocial and helping behavior, it is important for investigators to further enhance our understanding of its correlates and outcomes among health professionals.
Cirino, Lauren A.; Miller, Christine W.
2017-01-01
Many insects are influenced by the phenology of their host plants. In North Central Florida, Narnia femorata (Hemiptera: Coreidae) spends its entire life cycle living and feeding on Opuntia mesacantha ssp. lata. This cactus begins producing flower buds in April that lead to unripe green fruit in June that ripen into red fruit through December. Many morphological and behavioral characteristics of N. femorata are known to be affected by cactus phenology in a controlled laboratory setting, including the degree of sexual dimorphism and mating behavior. Our goal with this study was to determine if similar phenotypic changes of N. femorata occurred over time in the wild, and the extent to which these changes were concordant with phenological changes in its host plant. Further, we investigate the length of the insect mouthparts (beak) over time. Ongoing work has suggested that beak length may change across cohorts of developing insects in response to feeding deep within cactus fruit where seed and pulp depth decrease as the fruit ripens. Our results revealed a drop in cactus fruit abundance between the months of July through October 2015 as cactus fruits turned red and ripened. Simultaneously, the average body size of both males and females of N. femorata declined at two sampled sites. Male hind femora (a sexually-selected weapon) decreased disproportionately in size over time so that males later in the year had relatively smaller hind femora for their body size. The sex-specific patterns of morphological change led to increased sexual-size dimorphism and decreased sexual dimorphism for hind femora later in the year. Further, we found that beak length decreased across cohorts of insects as cactus fruit ripened, suggesting phenotypic plasticity in mouthpart length. Behavioral studies revealed that female readiness to mate increased as the season progressed. In sum, we found pronounced changes in the phenotypes of these insects in the field. Although this study is far from comprehensive, it provides tantalizing patterns that suggest many directions for future research. PMID:28106715
40 CFR 600.501-12 - General applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy § 600.501-12 General applicability. The provisions of this subpart are applicable to 2012 and later model year passenger automobiles...
40 CFR 600.501-85 - General applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy § 600.501-85 General... applicable to 1985 and later model year gasoline-fueled and diesel automobiles. (b)(1) Manufacturers that...
Sampling probability distributions of lesions in mammograms
NASA Astrophysics Data System (ADS)
Looney, P.; Warren, L. M.; Dance, D. R.; Young, K. C.
2015-03-01
One approach to image perception studies in mammography using virtual clinical trials involves the insertion of simulated lesions into normal mammograms. To facilitate this, a method has been developed that allows for sampling of lesion positions across the cranio-caudal and medio-lateral radiographic projections in accordance with measured distributions of real lesion locations. 6825 mammograms from our mammography image database were segmented to find the breast outline. The outlines were averaged and smoothed to produce an average outline for each laterality and radiographic projection. Lesions in 3304 mammograms with malignant findings were mapped on to a standardised breast image corresponding to the average breast outline using piecewise affine transforms. A four dimensional probability distribution function was found from the lesion locations in the cranio-caudal and medio-lateral radiographic projections for calcification and noncalcification lesions. Lesion locations sampled from this probability distribution function were mapped on to individual mammograms using a piecewise affine transform which transforms the average outline to the outline of the breast in the mammogram. The four dimensional probability distribution function was validated by comparing it to the two dimensional distributions found by considering each radiographic projection and laterality independently. The correlation of the location of the lesions sampled from the four dimensional probability distribution function across radiographic projections was shown to match the correlation of the locations of the original mapped lesion locations. The current system has been implemented as a web-service on a server using the Python Django framework. The server performs the sampling, performs the mapping and returns the results in a javascript object notation format.
Blight, Louise K.
2011-01-01
Seabirds integrate information about oceanic ecosystems across time and space, and are considered sensitive indicators of marine conditions. To assess whether hypothesized long-term foodweb changes such as forage fish declines may be reflected in a consumer's life history traits over time, I used meta-regression to evaluate multi-decadal changes in aspects of egg production in the glaucous-winged gull (Larus glaucescens), a common coastal bird. Study data were derived from literature searches of published papers and unpublished historical accounts, museum egg collections, and modern field studies, with inclusion criteria based on data quality and geographic area of the original study. Combined historical and modern data showed that gull egg size declined at an average of 0.04 cc y−1 from 1902 (108 y), equivalent to a decline of 5% of mean egg volume, while clutch size decreased over 48 y from a mean of 2.82 eggs per clutch in 1962 to 2.25 in 2009. There was a negative relationship between lay date and mean clutch size in a given year, with smaller clutches occurring in years where egg laying commenced later. Lay date itself advanced over time, with commencement of laying presently (2008–2010) 7 d later than in previous studies (1959–1986). This study demonstrates that glaucous-winged gull investment in egg production has declined significantly over the past ∼50–100 y, with such changes potentially contributing to recent population declines. Though gulls are generalist feeders that should readily be able to buffer themselves against food web changes, they are likely nutritionally constrained during the early breeding period, when egg production requirements are ideally met by consumption of high-quality prey such as forage fish. This study's results suggest a possible decline in the availability of such prey, and the incremental long-term impoverishment of a coastal marine ecosystem bordering one of North America's rapidly growing urban areas. PMID:21789207
Response of vegetation phenology to urbanization in the conterminous United States.
Li, Xuecao; Zhou, Yuyu; Asrar, Ghassem R; Mao, Jiafu; Li, Xiaoma; Li, Wenyu
2017-07-01
The influence of urbanization on vegetation phenology is gaining considerable attention due to its implications for human health, cycling of carbon and other nutrients in Earth system. In this study, we examined the relationship between change in vegetation phenology and urban size, an indicator of urbanization, for the conterminous United States. We studied more than 4500 urban clusters of varying size to determine the impact of urbanization on plant phenology, with the aids of remotely sensed observations since 2003-2012. We found that phenology cycle (changes in vegetation greenness) in urban areas starts earlier (start of season, SOS) and ends later (end of season, EOS), resulting in a longer growing season length (GSL), when compared to the respective surrounding urban areas. The average difference of GSL between urban and rural areas over all vegetation types, considered in this study, is about 9 days. Also, the extended GSL in urban area is consistent among different climate zones in the United States, whereas their magnitudes are varying across regions. We found that a tenfold increase in urban size could result in an earlier SOS of about 1.3 days and a later EOS of around 2.4 days. As a result, the GSL could be extended by approximately 3.6 days with a range of 1.6-6.5 days for 25th ~ 75th quantiles, with a median value of about 2.1 days. For different vegetation types, the phenology response to urbanization, as defined by GSL, ranges from 1 to 4 days. The quantitative relationship between phenology and urbanization is of great use for developing improved models of vegetation phenology dynamics under future urbanization, and for developing change indicators to assess the impacts of urbanization on vegetation phenology. © 2016 John Wiley & Sons Ltd.
A green chemistry approach for synthesizing biocompatible gold nanoparticles.
Gurunathan, Sangiliyandi; Han, JaeWoong; Park, Jung Hyun; Kim, Jin-Hoi
2014-01-01
Gold nanoparticles (AuNPs) are a fascinating class of nanomaterial that can be used for a wide range of biomedical applications, including bio-imaging, lateral flow assays, environmental detection and purification, data storage, drug delivery, biomarkers, catalysis, chemical sensors, and DNA detection. Biological synthesis of nanoparticles appears to be simple, cost-effective, non-toxic, and easy to use for controlling size, shape, and stability, which is unlike the chemically synthesized nanoparticles. The aim of this study was to synthesize homogeneous AuNPs using pharmaceutically important Ganoderma spp. We developed a simple, non-toxic, and green method for water-soluble AuNP synthesis by treating gold (III) chloride trihydrate (HAuCl4) with a hot aqueous extract of the Ganoderma spp. mycelia. The formation of biologically synthesized AuNPs (bio-AuNPs) was characterized by ultraviolet (UV)-visible absorption spectroscopy, X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), energy dispersive X-ray (EDX), dynamic light scattering (DLS), and transmission electron microscopy (TEM). Furthermore, the biocompatibility of as-prepared AuNPs was evaluated using a series of assays, such as cell viability, lactate dehydrogenase leakage, and reactive oxygen species generation (ROS) in human breast cancer cells (MDA-MB-231). The color change of the solution from yellow to reddish pink and strong surface plasmon resonance were observed at 520 nm using UV-visible spectroscopy, and that indicated the formation of AuNPs. DLS analysis revealed the size distribution of AuNPs in liquid solution, and the average size of AuNPs was 20 nm. The size and morphology of AuNPs were investigated using TEM. The biocompatibility effect of as-prepared AuNPs was investigated in MDA-MB-231 breast cancer cells by using various concentrations of AuNPs (10 to 100 μM) for 24 h. Our findings suggest that AuNPs are non-cytotoxic and biocompatible. To the best of our knowledge, this is the first report to describe the synthesis of monodispersed, biocompatible, and soluble AuNPs with an average size of 20 nm using Ganoderma spp. This study opens up new possibilities of using an inexpensive and non-toxic mushroom extract as a reducing and stabilizing agent for the synthesis of size-controlled, large-scale, biocompatible, and monodispersed AuNPs, which may have future diagnostic and therapeutic applications.
A green chemistry approach for synthesizing biocompatible gold nanoparticles
NASA Astrophysics Data System (ADS)
Gurunathan, Sangiliyandi; Han, JaeWoong; Park, Jung Hyun; Kim, Jin-Hoi
2014-05-01
Gold nanoparticles (AuNPs) are a fascinating class of nanomaterial that can be used for a wide range of biomedical applications, including bio-imaging, lateral flow assays, environmental detection and purification, data storage, drug delivery, biomarkers, catalysis, chemical sensors, and DNA detection. Biological synthesis of nanoparticles appears to be simple, cost-effective, non-toxic, and easy to use for controlling size, shape, and stability, which is unlike the chemically synthesized nanoparticles. The aim of this study was to synthesize homogeneous AuNPs using pharmaceutically important Ganoderma spp . We developed a simple, non-toxic, and green method for water-soluble AuNP synthesis by treating gold (III) chloride trihydrate (HAuCl4) with a hot aqueous extract of the Ganoderma spp . mycelia. The formation of biologically synthesized AuNPs (bio-AuNPs) was characterized by ultraviolet (UV)-visible absorption spectroscopy, X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), energy dispersive X-ray (EDX), dynamic light scattering (DLS), and transmission electron microscopy (TEM). Furthermore, the biocompatibility of as-prepared AuNPs was evaluated using a series of assays, such as cell viability, lactate dehydrogenase leakage, and reactive oxygen species generation (ROS) in human breast cancer cells (MDA-MB-231). The color change of the solution from yellow to reddish pink and strong surface plasmon resonance were observed at 520 nm using UV-visible spectroscopy, and that indicated the formation of AuNPs. DLS analysis revealed the size distribution of AuNPs in liquid solution, and the average size of AuNPs was 20 nm. The size and morphology of AuNPs were investigated using TEM. The biocompatibility effect of as-prepared AuNPs was investigated in MDA-MB-231 breast cancer cells by using various concentrations of AuNPs (10 to 100 μM) for 24 h. Our findings suggest that AuNPs are non-cytotoxic and biocompatible. To the best of our knowledge, this is the first report to describe the synthesis of monodispersed, biocompatible, and soluble AuNPs with an average size of 20 nm using Ganoderma spp. This study opens up new possibilities of using an inexpensive and non-toxic mushroom extract as a reducing and stabilizing agent for the synthesis of size-controlled, large-scale, biocompatible, and monodispersed AuNPs, which may have future diagnostic and therapeutic applications.
Protection of obstetric dimensions in a small-bodied human sample.
Kurki, Helen K
2007-08-01
In human females, the bony pelvis must find a balance between being small (narrow) for efficient bipedal locomotion, and being large to accommodate a relatively large newborn. It has been shown that within a given population, taller/larger-bodied women have larger pelvic canals. This study investigates whether in a population where small body size is the norm, pelvic geometry (size and shape), on average, shows accommodation to protect the obstetric canal. Osteometric data were collected from the pelves, femora, and clavicles (body size indicators) of adult skeletons representing a range of adult body size. Samples include Holocene Later Stone Age (LSA) foragers from southern Africa (n = 28 females, 31 males), Portuguese from the Coimbra-identified skeletal collection (CISC) (n = 40 females, 40 males) and European-Americans from the Hamann-Todd osteological collection (H-T) (n = 40 females, 40 males). Patterns of sexual dimorphism are similar in the samples. Univariate and multivariate analyses of raw and Mosimann shape-variables indicate that compared to the CISC and H-T females, the LSA females have relatively large midplane and outlet canal planes (particularly posterior and A-P lengths). The LSA males also follow this pattern, although with absolutely smaller pelves in multivariate space. The CISC females, who have equally small stature, but larger body mass, do not show the same type of pelvic canal size and shape accommodation. The results suggest that adaptive allometric modeling in at least some small-bodied populations protects the obstetric canal. These findings support the use of population-specific attributes in the clinical evaluation of obstetric risk. (c) 2007 Wiley-Liss, Inc.
Blizzard, Daniel J; Thomas, J Alex
2018-03-15
Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with intraoperative repositioning and may lead to significant improvements in operative efficiency and cost savings. 4.
Lateral Patellofemoral Ligament: An Anatomic Study.
Shah, Kalpit N; DeFroda, Steven F; Ware, James Kristopher; Koruprolu, Sarath C; Owens, Brett D
2017-12-01
Medial instability of the patellofemoral joint is a rare but known phenomenon that may result from an incompetent lateral patellofemoral ligament (LPFL). Surgical reconstruction of the LPFL has been described. However, anatomic details of the ligament have not been the subject of scrutiny. To describe the anatomic origin and insertion of the LPFL. Descriptive laboratory study. Ten fresh-frozen, unpaired human cadaveric knees (mean age, 57 years) were dissected to identify the LPFL. The dissection was carried out by elevating the iliotibial band to expose the deep capsular layer of the knee joint, followed by a medial parapatellar approach to the knee. Then the quadriceps and patellar tendons were sectioned, and the LPFL was isolated by visualization and palpation. The LPFL was dissected to reveal its origin and insertion; these were measured with respect to the lateral epicondyle and the superior-inferior axis of the lateral patella, respectively. On average, the LPFL had a variable point of origin in location as well as width about the lateral epicondyle. The LPFL originated, on average, 2.6 mm distal (range, 13.1 mm proximal to 11.4 mm distal) and 10.8 mm anterior (range, 7.3 mm posterior to 14.9 mm anterior) to the lateral epicondyle. The LPFL insertion on the patella was more reliably found to be about 45% (range, 23.7%-58.4%) of its lateral articular surface. The insertion on the patella was found to be in the middle third of the lateral patella. The LPFL has an origin that is variable but, on average, was found to be distal and anterior to the lateral epicondyle. The patella insertion was more reliably found to be in the middle third of the lateral patella. These anatomic relationships can help the surgeon reconstruct the LPFL in a more anatomic fashion. Surgeons who are tasked with reconstruction of the LPFL of a patient with idiopathic medial instability or a previous aggressive lateral release of the knee may reference this article to perform an anatomic reconstruction of the LPFL. We hope that having anatomic landmarks for the reconstruction of this ligament permits the surgeon to operate in an efficient manner that allows for the optimal outcome. This is a rare surgical issue, and no studies are available that provide this information. The little information present in the literature does not provide measurements for anatomic reconstruction; rather, it is limited to descriptions of reconstruction techniques that indirectly provide stability on the lateral aspect of the knee.
Ensemble representations: effects of set size and item heterogeneity on average size perception.
Marchant, Alexander P; Simons, Daniel J; de Fockert, Jan W
2013-02-01
Observers can accurately perceive and evaluate the statistical properties of a set of objects, forming what is now known as an ensemble representation. The accuracy and speed with which people can judge the mean size of a set of objects have led to the proposal that ensemble representations of average size can be computed in parallel when attention is distributed across the display. Consistent with this idea, judgments of mean size show little or no decrement in accuracy when the number of objects in the set increases. However, the lack of a set size effect might result from the regularity of the item sizes used in previous studies. Here, we replicate these previous findings, but show that judgments of mean set size become less accurate when set size increases and the heterogeneity of the item sizes increases. This pattern can be explained by assuming that average size judgments are computed using a limited capacity sampling strategy, and it does not necessitate an ensemble representation computed in parallel across all items in a display. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org
Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according tomore » measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A; Pasciak, A; Wagner, L
Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluationsmore » studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.« less
Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy.
Jones, A Kyle; Pasciak, Alexander S; Wagner, Louis K
2016-07-01
To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (Eavg) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.
Thin-plate spline analysis of mandibular growth.
Franchi, L; Baccetti, T; McNamara, J A
2001-04-01
The analysis of mandibular growth changes around the pubertal spurt in humans has several important implications for the diagnosis and orthopedic correction of skeletal disharmonies. The purpose of this study was to evaluate mandibular shape and size growth changes around the pubertal spurt in a longitudinal sample of subjects with normal occlusion by means of an appropriate morphometric technique (thin-plate spline analysis). Ten mandibular landmarks were identified on lateral cephalograms of 29 subjects at 6 different developmental phases. The 6 phases corresponded to 6 different maturational stages in cervical vertebrae during accelerative and decelerative phases of the pubertal growth curve of the mandible. Differences in shape between average mandibular configurations at the 6 developmental stages were visualized by means of thin-plate spline analysis and subjected to permutation test. Centroid size was used as the measure of the geometric size of each mandibular specimen. Differences in size at the 6 developmental phases were tested statistically. The results of graphical analysis indicated a statistically significant change in mandibular shape only for the growth interval from stage 3 to stage 4 in cervical vertebral maturation. Significant increases in centroid size were found at all developmental phases, with evidence of a prepubertal minimum and of a pubertal maximum. The existence of a pubertal peak in human mandibular growth, therefore, is confirmed by thin-plate spline analysis. Significant morphological changes in the mandible during the growth interval from stage 3 to stage 4 in cervical vertebral maturation may be described as an upward-forward direction of condylar growth determining an overall "shrinkage" of the mandibular configuration along the measurement of total mandibular length. This biological mechanism is particularly efficient in compensating for major increments in mandibular size at the adolescent spurt.
Orozco-Varo, Ana; Arroyo-Cruz, Gema; Martínez-de-Fuentes, Rafael; Jiménez-Castellanos, Emilio
2015-06-01
Restorative dentistry often involves correcting tooth size discrepancies. Therefore, dental biometrics should play an important role in the planning of an esthetic restoration. The purpose of this study was to analyze the clinical crown width, length, and width/length ratio of maxillary central incisors, lateral incisors, and canines in an adult population. The study also aimed to determine whether a correlation exists between natural tooth dimensions and the optimal tooth dimension guidelines suggested for planning esthetic restorations. Stone casts were poured from irreversible hydrocolloid impressions of 412 healthy adult participants. These casts were used to measure the maximum mesiodistal width and maximum crown-root length of the maxillary central incisors, lateral incisors, and canines with a digital precision caliper (0.01 mm). The width/length ratio was calculated for each tooth, and 40 casts were selected to test the reliability of the measuring method. The mean age of the participants in the sample was 33.94 years; 60.7% were women and 39.3% were men. The mean width value was 8.71 mm for central incisors, 6.75 mm for lateral incisors, and 7.81 mm for canines. The mean length was 10.23 mm for central incisors, 8.59 mm for lateral incisors, and 9.93 mm for canines. The average width/length ratio was 85% for central incisors and 79% for lateral incisors and canines. The data obtained from the population studied are similar to those from previous research studies with similar methodology. However, great discrepancies in the absolute values were found when compared with other studies of ideal tooth dimension guidelines on the personal preferences and the esthetic perception of dentists. The perception of what is considered natural seems to differ from what is considered esthetically perfect. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Weighting by Inverse Variance or by Sample Size in Random-Effects Meta-Analysis
ERIC Educational Resources Information Center
Marin-Martinez, Fulgencio; Sanchez-Meca, Julio
2010-01-01
Most of the statistical procedures in meta-analysis are based on the estimation of average effect sizes from a set of primary studies. The optimal weight for averaging a set of independent effect sizes is the inverse variance of each effect size, but in practice these weights have to be estimated, being affected by sampling error. When assuming a…
Symmetry breaking in binary mixtures in closed nanoslits.
Berim, Gersh O; Ruckenstein, Eli
2008-04-07
The symmetry breaking (SB) of the fluid density distribution (FDD) in closed nanoslits between two identical parallel solid walls described by Berim and Ruckenstein [J. Chem. Phys. 128, 024704 (2008)] for a single component fluid is examined for binary mixtures on the basis of a nonlocal canonical ensemble density functional theory. As in Monte Carlo simulations, the periodicity of the FDD in one of the lateral (parallel to the wall surfaces) directions, denoted as the x direction, was assumed. In the other lateral direction, y direction, the FDD was considered to be uniform. The molecules of the two components have different diameters and their Lennard-Jones interaction potentials have different energy parameters. It was found that depending on the average fluid density in the slit and mixture composition, SB can occur for both or none of the components but never for only one of them. In the direction perpendicular to the walls (h direction), the FDDs of both components can be asymmetrical about the middle plane between walls. In the x direction, the SB occurs as bumps and bridges enriched in one of the components, whereas the composition of the mixture between them is enriched in the other component. The dependence of the SB states on the length Lx of the FDD period at fixed average densities of the two components was examined for Lx in the range from 10 to 120 molecular diameters of the smaller size component. It was shown that for large Lx, the stable state of the system corresponds to a bridge. Because the free energy of that state decreases monotonically with increasing Lx, one can conclude that the real period is very large (infinite) and that a single bridge exists in the slit.
Symmetry breaking in binary mixtures in closed nanoslits
NASA Astrophysics Data System (ADS)
Berim, Gersh O.; Ruckenstein, Eli
2008-04-01
The symmetry breaking (SB) of the fluid density distribution (FDD) in closed nanoslits between two identical parallel solid walls described by Berim and Ruckenstein [J. Chem. Phys. 128, 024704 (2008)] for a single component fluid is examined for binary mixtures on the basis of a nonlocal canonical ensemble density functional theory. As in Monte Carlo simulations, the periodicity of the FDD in one of the lateral (parallel to the wall surfaces) directions, denoted as the x direction, was assumed. In the other lateral direction, y direction, the FDD was considered to be uniform. The molecules of the two components have different diameters and their Lennard-Jones interaction potentials have different energy parameters. It was found that depending on the average fluid density in the slit and mixture composition, SB can occur for both or none of the components but never for only one of them. In the direction perpendicular to the walls (h direction), the FDDs of both components can be asymmetrical about the middle plane between walls. In the x direction, the SB occurs as bumps and bridges enriched in one of the components, whereas the composition of the mixture between them is enriched in the other component. The dependence of the SB states on the length Lx of the FDD period at fixed average densities of the two components was examined for Lx in the range from 10 to 120 molecular diameters of the smaller size component. It was shown that for large Lx, the stable state of the system corresponds to a bridge. Because the free energy of that state decreases monotonically with increasing Lx, one can conclude that the real period is very large (infinite) and that a single bridge exists in the slit.
The rigid-plate and shrinking-plate hypotheses: Implications for the azimuths of transform faults
NASA Astrophysics Data System (ADS)
Mishra, Jay Kumar; Gordon, Richard G.
2016-08-01
The rigid-plate hypothesis implies that oceanic lithosphere does not contract horizontally as it cools (hereinafter "rigid plate"). An alternative hypothesis, that vertically averaged tensional thermal stress in the competent lithosphere is fully relieved by horizontal thermal contraction (hereinafter "shrinking plate"), predicts subtly different azimuths for transform faults. The size of the predicted difference is as large as 2.44° with a mean and median of 0.46° and 0.31°, respectively, and changes sign between right-lateral (RL)-slipping and left-lateral (LL)-slipping faults. For the MORVEL transform-fault data set, all six plate pairs with both RL- and LL-slipping faults differ in the predicted sense, with the observed difference averaging 1.4° ± 0.9° (95% confidence limits), which is consistent with the predicted difference of 0.9°. The sum-squared normalized misfit, r, to global transform-fault azimuths is minimized for γ = 0.8 ± 0.4 (95% confidence limits), where γ is the fractional multiple of the predicted difference in azimuth between the shrinking-plate (γ = 1) and rigid-plate (γ = 0) hypotheses. Thus, observed transform azimuths differ significantly between RL-slipping and LL-slipping faults, which is inconsistent with the rigid-plate hypothesis but consistent with the shrinking-plate hypothesis, which indicates horizontal shrinking rates of 2% Ma-1 for newly created lithosphere, 1% Ma-1 for 0.1 Ma old lithosphere, 0.2% Ma-1 for 1 Ma old lithosphere, and 0.02% Ma-1 for 10 Ma old lithosphere, which are orders of magnitude higher than the mean intraplate seismic strain rate of 10-6 Ma-1 (5 × 10-19 s-1).
The Lateral Decubitus Breast Boost: Description, Rationale, and Efficacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ludwig, Michelle S., E-mail: mludwig@mdanderson.or; McNeese, Marsha D.; Buchholz, Thomas A.
2010-01-15
Purpose: To describe and evaluate the modified lateral decubitus boost, a breast irradiation technique. Patients are repositioned and resimulated for electron boost to minimize the necessary depth for the electron beam and optimize target volume coverage. Methods and Materials: A total of 2,606 patients were treated with post-lumpectomy radiation at our institution between January 1, 2000, and February 1, 2008. Of these, 231 patients underwent resimulation in the lateral decubitus position with electron boost. Distance from skin to the maximal depth of target volume was measured in both the original and boost plans. Age, body mass index (BMI), boost electronmore » energy, and skin reaction were evaluated. Results: Resimulation in the lateral decubitus position reduced the distance from skin to maximal target volume depth in all patients. Average depth reduction by repositioning was 2.12 cm, allowing for an average electron energy reduction of approximately 7 MeV. Mean skin entrance dose was reduced from about 90% to about 85% (p < 0.001). Only 14 patients (6%) experienced moist desquamation in the boost field at the end of treatment. Average BMI of these patients was 30.4 (range, 17.8-50.7). BMI greater than 30 was associated with more depth reduction by repositioning and increased risk of moist desquamation. Conclusions: The lateral decubitus position allows for a decrease in the distance from the skin to the target volume depth, improving electron coverage of the tumor bed while reducing skin entrance dose. This is a well-tolerated regimen for a patient population with a high BMI or deep tumor location.« less
Decrumpling membranes by quantum effects
NASA Astrophysics Data System (ADS)
Borelli, M. E. S.; Kleinert, H.
2001-02-01
The phase diagram of an incompressible fluid membrane subject to quantum and thermal fluctuations is calculated exactly in a large number of dimensions of configuration space. At zero temperature, a crumpling transition is found at a critical bending rigidity 1/αc. For membranes of fixed lateral size, a crumpling transition occurs at nonzero temperatures in an auxiliary mean field approximation. As the lateral size L of the membrane becomes large, the flat regime shrinks with 1/ln L.
NASA Astrophysics Data System (ADS)
Feng, Y. P.; Sinha, S. K.; Melendres, C. A.; Lee, D. D.
1996-02-01
We have studied the electrochemically-induced pitting process on a Cu electrode in NaHCO 3 solution using in-situ X-ray off-specular reflectivity measurements. The morphology and growth dynamics of the localized corrosion sites or pits were studied as the applied potential was varied from the cathodic region where the Cu surface is relatively free of oxide films to the anodic region where surface roughening occurs by general corrosion with concomitant formation of an oxide film. Quantitative analysis of the experimental results indicates that early pitting proceeds in favor of nucleation of pit clusters over individual pit growth. It was found that the lateral distribution of the pits is not random but exhibits a short-range order as evidenced by the appearance of a side peak in the transverse off-specular reflectivity. The position, height, and width of the peak was modeled to yield the average size, nearest-neighbor distance (within any one of the clusters), and over-all density of the pits averaged over the entire illuminated surface. In addition, measurements of the longitudinal off-specular reflectivity indicate a bimodal depth distribution for the pits, suggesting a “film breaking” type of pitting mechanism.
Later Start, Longer Sleep: Implications of Middle School Start Times.
Temkin, Deborah A; Princiotta, Daniel; Ryberg, Renee; Lewin, Daniel S
2018-05-01
Although adolescents generally get less than the recommended 9 hours of sleep per night, research and effort to delay school start times have generally focused on high schools. This study assesses the relation between school start times and sleep in middle school students while accounting for potentially confounding demographic variables. Seventh and eighth grade students attending 8 late starting schools (∼8:00 am, n = 630) and 3 early starting schools (∼7:23 am, n = 343) from a diverse suburban school district completed online surveys about their sleep behaviors. Doubly robust inverse probability of treatment weighted regression estimates of the effects of later school start time on student bedtimes, sleep duration, and daytime sleepiness were generated. Attending a school starting 37 minutes later was associated with an average of 17 additional minutes of sleep per weeknight, despite an average bedtime 15 minutes later. Students attending late starting schools were less sleepy than their counterparts in early starting schools, and more likely to be wide awake. Later school start times were significantly associated with improved sleep outcomes for early adolescents, providing support for the movement to delay school start times for middle schools. © 2018, American School Health Association.
NASA Technical Reports Server (NTRS)
Weick, Fred E; Wenzinger, Carl J
1935-01-01
This report covers the twelfth of a series of tests conducted to compare different lateral control devices with particular reference to their effectiveness at high angles of attack. The present wind tunnel tests were made with two sizes of upper-surface ailerons on rectangular Clark Y wing models equipped with full span split flaps. The tests showed the effect of the upper-surface ailerons and of the split flaps on the general performance characteristics of the wings, and on the lateral controllability and stability characteristics. The results are compared with those for plain wings with ordinary ailerons of similar sizes.
Munoz-Menendez, Cristina; Conde-Leboran, Ivan; Baldomir, Daniel; Chubykalo-Fesenko, Oksana; Serantes, David
2015-11-07
An efficient and safe hyperthermia cancer treatment requires the accurate control of the heating performance of magnetic nanoparticles, which is directly related to their size. However, in any particle system the existence of some size polydispersity is experimentally unavoidable, which results in a different local heating output and consequently a different hyperthermia performance depending on the size of each particle. With the aim to shed some light on this significant issue, we have used a Monte Carlo technique to study the role of size polydispersity in heat dissipation at both the local (single particle) and global (macroscopic average) levels. We have systematically varied size polydispersity, temperature and interparticle dipolar interaction conditions, and evaluated local heating as a function of these parameters. Our results provide a simple guide on how to choose, for a given polydispersity degree, the more adequate average particle size so that the local variation in the released heat is kept within some limits that correspond to safety boundaries for the average-system hyperthermia performance. All together we believe that our results may help in the design of more effective magnetic hyperthermia applications.
Anufriieva, Elena V.; Shadrin, Nickolai V.
2014-01-01
Arctodiaptomus salinus inhabits water bodies across Eurasia and North Africa. Based on our own data and that from the literature, we analyzed the influences of several factors on the intra- and inter-population variability of this species. A strong negative linear correlation between temperature and average body size in the Crimean and African populations was found, in which the parameters might be influenced by salinity. Meanwhile, asignificant negative correlation between female body size and the altitude of habitats was found by comparing body size in populations from different regions. Individuals from environments with highly varying abiotic parameters, e.g. temporary reservoirs, had a larger body size than individuals from permanent water bodies. The changes in average body mass in populations were at 11.4 times, whereas, those in individual metabolic activities were at 6.2 times. Moreover, two size groups of A. salinus in the Crimean and the Siberian lakes were observed. The ratio of female length to male length fluctuatedbetween 1.02 and 1.30. The average size of A. salinus in populations and its variations were determined by both genetic and environmental factors. However, the paritiesof these factors were unequal in either spatial or temporal scales. PMID:24668656
Anufriieva, Elena V; Shadrin, Nickolai V
2014-03-01
Arctodiaptomus salinus inhabits water bodies across Eurasia and North Africa. Based on our own data and that from the literature, we analyzed the influences of several factors on the intra- and inter-population variability of this species. A strong negative linear correlation between temperature and average body size in the Crimean and African populations was found, in which the parameters might be influenced by salinity. Meanwhile, a significant negative correlation between female body size and the altitude of habitats was found by comparing body size in populations from different regions. Individuals from environments with highly varying abiotic parameters, e.g. temporary reservoirs, had a larger body size than individuals from permanent water bodies. The changes in average body mass in populations were at 11.4 times, whereas, those in individual metabolic activities were at 6.2 times. Moreover, two size groups of A. salinus in the Crimean and the Siberian lakes were observed. The ratio of female length to male length fluctuated between 1.02 and 1.30. The average size of A. salinus in populations and its variations were determined by both genetic and environmental factors. However, the parities of these factors were unequal in either spatial or temporal scales.
Kerrigan, Elizabeth A.; Irwin, Andrew J.
2015-01-01
Climate change over the last two centuries has been associated with significant shifts in diatom community structure in lakes from the high arctic to temperate latitudes. To test the hypotheses that recent climate warming selects for species of smaller size within communities and a decrease in the average size of species within populations, we quantified the size of individual diatom valves from 10 depths in a sediment core covering the last ∼200 years from a pristine subarctic lake. Over the last ∼200 years, changes in the relative abundance of species of different average size and changes in the average valve size of populations of species contribute equally to the changes in community size structure, but are often opposite in sign, compensating for one another and moderating temporal changes in community size structure. In the surface sediments that correspond to the recent decades when air temperatures have warmed, the mean size of valves in the diatom community has significantly decreased due to an increase in the proportion of smaller-sized planktonic diatom species. PMID:26157637
40 CFR 600.512-86 - Model year report.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... submitted. (3) Separate reports shall be submitted for passenger automobiles and light trucks (as identified...
40 CFR 600.512-01 - Model year report.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... report must be submitted. (3) Separate reports shall be submitted for passenger automobiles and light...
40 CFR 600.512-08 - Model year report.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... report must be submitted. (3) Separate reports shall be submitted for passenger automobiles and light...
Sjodahl, Mikael; Amer, Eynas
2018-05-10
The two techniques of lateral shear interferometry and speckle deflectometry are analyzed in a common optical system for their ability to measure phase gradient fields of a thin phase object. The optical system is designed to introduce a shear in the frequency domain of a telecentric imaging system that gives a sensitivity of both techniques in proportion to the defocus introduced. In this implementation, both techniques successfully measure the horizontal component of the phase gradient field. The response of both techniques scales linearly with the defocus distance, and the precision is comparative, with a random error in the order of a few rad/mm. It is further concluded that the precision of the two techniques relates to the transverse speckle size in opposite ways. While a large spatial coherence width, and correspondingly a large lateral speckle size, makes lateral shear interferometry less susceptible to defocus, a large lateral speckle size is detrimental for speckle correlation. The susceptibility for the magnitude of the defocus is larger for the lateral shear interferometry technique as compared to the speckle deflectometry technique. The two techniques provide the same type of information; however, there are a few fundamental differences. Lateral shear interferometry relies on a special hardware configuration in which the shear angle is intrinsically integrated into the system. The design of a system sensitive to both in-plane phase gradient components requires a more complex configuration and is not considered in this paper. Speckle deflectometry, on the other hand, requires no special hardware, and both components of the phase gradient field are given directly from the measured speckle deformation field.
SU-F-BRCD-03: Dose Calculation of Electron Therapy Using Improved Lateral Buildup Ratio Method.
Gebreamlak, W; Tedeschi, D; Alkhatib, H
2012-06-01
To calculate the percentage depth dose of any irregular shape electron beam using modified lateral build-up-ratio method. Percentage depth dose (PDD) curves were measured using 6, 9, 12, and 15MeV electron beam energies for applicator cone sizes of 6×6, 10×10, 14×14, and 14×14cm 2 . Circular cutouts for each cone were prepared from 2.0cm diameter to the maximum possible size for each cone. In addition, three irregular cutouts were prepared. The scanning was done using a water tank and two diodes - one for the signal and the other a stationary reference outside the tank. The water surface was determined by scanning the signal diode slowly from water to air and by noting the sharp change of the percentage depth dose curve at the water/air interface. The lateral build-up-ratio (LBR) for each circular cutout was calculated from the measured PDD curve using the open field of the 14×14 cm 2 cone as the reference field. Using the LBR values and the radius of the circular cutouts, the corresponding lateral spread parameter (sigma) of the electron shower was calculated. Unlike the commonly accepted assumption that sigma is independent of cutout size, it is shown that the sigma value increases linearly with circular cutout size. Using this characteristic of sigma, the PDD curves of irregularly shaped cutouts were calculated. Finally, the calculated PDD curves were compared with measured PDD curves. In this research, it is shown that sigma increases with cutout size. For radius of circular cutout sizes up to the equilibrium range of the electron beam, the increase of sigma with the cutout size is linear. The percentage difference of the calculated PDD from the measured PDD for irregularly shaped cutouts was under 1.0%. Similar Result was obtained for four electron beam energies (6, 9, 12, and 15MeV). © 2012 American Association of Physicists in Medicine.
Jackpot Structural Features: Rollover Effect and Goal-Gradient Effect in EGM Gambling.
Li, En; Rockloff, Matthew J; Browne, Matthew; Donaldson, Phillip
2016-06-01
Relatively little research has been undertaken on the influence of jackpot structural features on electronic gaming machine (EGM) gambling behavior. This study considered two common features of EGM jackpots: progressive (i.e., the jackpot incrementally growing in value as players make additional bets), and deterministic (i.e., a guaranteed jackpot after a fixed number of bets, which is determined in advance and at random). Their joint influences on player betting behavior and the moderating role of jackpot size were investigated in a crossed-design experiment. Using real money, players gambled on a computer simulated EGM with real jackpot prizes of either $500 (i.e., small jackpot) or $25,000 (i.e., large jackpot). The results revealed three important findings. Firstly, players placed the largest bets (20.3 % higher than the average) on large jackpot EGMs that were represented to be deterministic and non-progressive. This finding was supportive of a hypothesized 'goal-gradient effect', whereby players might have felt subjectively close to an inevitable payoff for a high-value prize. Secondly, large jackpots that were non-deterministic and progressive also promoted high bet sizes (17.8 % higher than the average), resembling the 'rollover effect' demonstrated in lottery betting, whereby players might imagine that their large bets could be later recouped through a big win. Lastly, neither the hypothesized goal-gradient effect nor the rollover effect was evident among players betting on small jackpot machines. These findings suggest that certain high-value jackpot configurations may have intensifying effects on player behavior.
NASA Astrophysics Data System (ADS)
Shaterabadi, Zhila; Nabiyouni, Gholamreza; Soleymani, Meysam
2018-06-01
Dextran-coated magnetite (Fe3O4) nanoparticles with average particle sizes of 4 and 19 nm were synthesized through in situ and semi-two-step co-precipitation methods, respectively. The experimental results confirm the formation of pure phase of magnetite as well as the presence of dextran layer on the surface of modified magnetite nanoparticles. The results also reveal that both samples have the superparamagnetic behavior. Furthermore, calorimetric measurements show that the dextran-coated Fe3O4 nanoparticles with an average size of 4 nm cannot produce any appreciable heat under a biologically safe alternating magnetic field used in hyperthermia therapy; whereas, the larger ones (average size of 19 nm) are able to increase the temperature of their surrounding medium up to above therapeutic range. In addition, measured specific absorption rate (SAR) values confirm that magnetite nanoparticles with an average size of 19 nm are very excellent candidates for application in magnetic hyperthermia therapy.
ERIC Educational Resources Information Center
Duffy, Karen G.; And Others
1982-01-01
Investigated the effects of experimenter status and sex and instructional set on the size of "sexy" and "average" human figure drawings by students. Results showed no effects for experimenter status or sex. "Sexy" drawings were consistently drawn larger than "average" drawings and male figures were drawn…
Transoral robotic approach to parapharyngeal space tumors: Case series and technical limitations.
Boyce, Brian J; Curry, Joseph M; Luginbuhl, Adam; Cognetti, David M
2016-08-01
The transoral robotic approach to parapharyngeal space (PPS) tumors is a new technique with limited data available on its feasibility, safety, and efficacy. We analyzed our experience with transoral robotic excisions of PPS tumors to evaluate the safety and efficacy of this technique. Retrospective chart analysis at tertiary academic medical center. From July 2010 to June 2014, 17 patients who had transoral robotic excision of PPS tumors were included in the study. Our cohort had an average age of 61.6 years and was 52.9% male. All patients had successful removal of their PPS tumors, and the average size of the tumors was 27.3 cm(3) (range 2-80 cm(3) ). Two cases (11.7%) required a cervical incision to assist with tumor removal. The average total operative time was 140.5 minutes. Two PPS PAs had focal areas of capsule rupture and one was fragmented. The average length of stay was 1.8 days (range 1-7 days), and all patients were discharged on an oral diet. Three patients experienced complications. There was no clinical or radiographic evidence of recurrence. This is the largest single-institution case series of transoral robotic approaches to PPS tumors. We demonstrate that this approach is feasible and safe but also note limitations of the robotic approaches for tumors on the far lateral and superior areas of the PPS, which required transcervical assistance. There were no patients who demonstrated recurrent tumor either radiographically or clinically. 4. Laryngoscope, 126:1776-1782, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Field-size dependence of doses of therapeutic carbon beams.
Kusano, Yohsuke; Kanai, Tatsuaki; Yonai, Shunsuke; Komori, Masataka; Ikeda, Noritoshi; Tachikawa, Yuji; Ito, Atsushi; Uchida, Hirohisa
2007-10-01
To estimate the physical dose at the center of spread-out Bragg peaks (SOBP) for various conditions of the irradiation system, a semiempirical approach was applied. The dose at the center of the SOBP depends on the field size because of large-angle scattering particles in the water phantom. For a small field of 5 x 5 cm2, the dose was reduced to 99.2%, 97.5%, and 96.5% of the dose used for the open field in the case of 290, 350, and 400 MeV/n carbon beams, respectively. Based on the three-Gaussian form of the lateral dose distributions of the carbon pencil beam, which has previously been shown to be effective for describing scattered carbon beams, we reconstructed the dose distributions of the SOBP beam. The reconstructed lateral dose distribution reproduced the measured lateral dose distributions very well. The field-size dependencies calculated using the reconstructed lateral dose distribution of the therapeutic carbon beam agreed with the measured dose dependency very well. The reconstructed beam was also used for irregularly shaped fields. The resultant dose distribution agreed with the measured dose distribution. The reconstructed beams were found to be applicable to the treatment-planning system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bang, W.; Quevedo, H. J.; Bernstein, A. C.
We measured the average deuterium cluster size within a mixture of deuterium clusters and helium gas by detecting Rayleigh scattering signals. The average cluster size from the gas mixture was comparable to that from a pure deuterium gas when the total backing pressure and temperature of the gas mixture were the same as those of the pure deuterium gas. According to these measurements, the average size of deuterium clusters depends on the total pressure and not the partial pressure of deuterium in the gas mixture. To characterize the cluster source size further, a Faraday cup was used to measure themore » average kinetic energy of the ions resulting from Coulomb explosion of deuterium clusters upon irradiation by an intense ultrashort pulse. The deuterium ions indeed acquired a similar amount of energy from the mixture target, corroborating our measurements of the average cluster size. As the addition of helium atoms did not reduce the resulting ion kinetic energies, the reported results confirm the utility of using a known cluster source for beam-target-fusion experiments by introducing a secondary target gas.« less
NASA Astrophysics Data System (ADS)
Burye, Theodore E.; Nicholas, Jason D.
2015-02-01
Here, for the first time, the average size of solid oxide fuel cell (SOFC) electrode nano-particles was reduced through the chemical desiccation of infiltrated precursor nitrate solutions. Specifically, after firing at 700 °C, CaCl2-desiccated La0.6Sr0.4Co0.8Fe0.2O3-δ (LSCF) - Ce0.9Gd0.1O1.95 (GDC) cathodes contained LSCF infiltrate particles with an average size of 22 nm. This is in contrast to comparable, undesiccated LSCF-GDC cathodes which contained LSCF infiltrate particles with an average size of 48 nm. X-ray diffraction, scanning electron microscopy, and controlled atmosphere electrochemical impedance spectroscopy revealed that desiccation reduced the average infiltrate particle size without altering the infiltrate phase purity, the cathode concentration polarization resistance, or the cathode electronic resistance. Compared to undesiccated LSCF-GDC cathodes achieving polarization resistances of 0.10 Ωcm2 at 640 °C, comparable CaCl2-dessicated LSCF-GDC cathodes achieved 0.10 Ωcm2 at 575 °C. Mathematical modeling suggested that these performance improvements resulted solely from average infiltrate particle size reductions.
Bang, W.; Quevedo, H. J.; Bernstein, A. C.; ...
2014-12-10
We measured the average deuterium cluster size within a mixture of deuterium clusters and helium gas by detecting Rayleigh scattering signals. The average cluster size from the gas mixture was comparable to that from a pure deuterium gas when the total backing pressure and temperature of the gas mixture were the same as those of the pure deuterium gas. According to these measurements, the average size of deuterium clusters depends on the total pressure and not the partial pressure of deuterium in the gas mixture. To characterize the cluster source size further, a Faraday cup was used to measure themore » average kinetic energy of the ions resulting from Coulomb explosion of deuterium clusters upon irradiation by an intense ultrashort pulse. The deuterium ions indeed acquired a similar amount of energy from the mixture target, corroborating our measurements of the average cluster size. As the addition of helium atoms did not reduce the resulting ion kinetic energies, the reported results confirm the utility of using a known cluster source for beam-target-fusion experiments by introducing a secondary target gas.« less
Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha
2017-09-01
A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.
Hartmann, Christina; Siegrist, Michael
2015-06-01
The present study investigated the longitudinal development of body size perception in relation to different personality traits. A sample of Swiss adults (N=2905, 47% men), randomly selected from the telephone book, completed a questionnaire on two consecutive years (2012, 2013). Body size perception was assessed with the Contour Drawing Rating Scale and personality traits were assessed with a short version of the Big Five Inventory. Longitudinal analysis of change indicated that men and women scoring higher on conscientiousness perceived themselves as thinner one year later. In contrast, women scoring higher on neuroticism perceived their body size as larger one year later. No significant effect was observed for men scoring higher on neuroticism. These results were independent of weight changes, body mass index, age, and education. Our findings suggest that personality traits contribute to body size perception among adults. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dubois, A B; Ogilvy, C S
1978-12-01
1. Pressures on the right and left sides of the tails of swimming bluefish were measured and found to have a range of +5.9 to -5.9 cm H2O. The pressures were resolved into their forward and lateral vectorial components of force to allow calculation of forward and lateral force and power at speeds ranging from 0.26 to 0.87 m/s. 2. The peak to peak changes in force of acceleration of the body, measured with a forward accelerometer averaged 209 g or 2.05 N at 0.48 m/s, and were compared with the maximum to minimum excursions of forward tail force averaging 201 g or 1.97 N at the same speed. The mean difference was 8 g, S.D. of the mean difference +/-29, SE. of mean difference +/-10 g. 3. Mean tail thrust was calculated as the time average of tail force in the forward direction. It averaged 65 g , or 0.64 N, at 0.48 m/s. The mean forward power was 0.34 N m/s at 0.48 m/s. The drag of the gauges and wires accounted for 10% of this figure. 4. The mean lateral power of the tail was 1.28 N m/s at a mean speed of 0.48 m/s. 5. The propulsive efficiency of the tail, calculated as the ratio of forward power to forward plus lateral power, was found to be 0.20 S.D.+/-0.04, S.E.+/-0.01 and was not related to speed. This suggests that 80% of the mechanical power of the tail was wasted. Turbulence in the water may have contributed to this large drag and low tail efficiency.
Surface slip during large Owens Valley earthquakes
NASA Astrophysics Data System (ADS)
Haddon, E. K.; Amos, C. B.; Zielke, O.; Jayko, A. S.; Bürgmann, R.
2016-06-01
The 1872 Owens Valley earthquake is the third largest known historical earthquake in California. Relatively sparse field data and a complex rupture trace, however, inhibited attempts to fully resolve the slip distribution and reconcile the total moment release. We present a new, comprehensive record of surface slip based on lidar and field investigation, documenting 162 new measurements of laterally and vertically displaced landforms for 1872 and prehistoric Owens Valley earthquakes. Our lidar analysis uses a newly developed analytical tool to measure fault slip based on cross-correlation of sublinear topographic features and to produce a uniquely shaped probability density function (PDF) for each measurement. Stacking PDFs along strike to form cumulative offset probability distribution plots (COPDs) highlights common values corresponding to single and multiple-event displacements. Lateral offsets for 1872 vary systematically from ˜1.0 to 6.0 m and average 3.3 ± 1.1 m (2σ). Vertical offsets are predominantly east-down between ˜0.1 and 2.4 m, with a mean of 0.8 ± 0.5 m. The average lateral-to-vertical ratio compiled at specific sites is ˜6:1. Summing displacements across subparallel, overlapping rupture traces implies a maximum of 7-11 m and net average of 4.4 ± 1.5 m, corresponding to a geologic Mw ˜7.5 for the 1872 event. We attribute progressively higher-offset lateral COPD peaks at 7.1 ± 2.0 m, 12.8 ± 1.5 m, and 16.6 ± 1.4 m to three earlier large surface ruptures. Evaluating cumulative displacements in context with previously dated landforms in Owens Valley suggests relatively modest rates of fault slip, averaging between ˜0.6 and 1.6 mm/yr (1σ) over the late Quaternary.
Outcome of Surgical Fixation of Lateral Column Distal Humerus Fractures.
Von Keudell, Arvind; Kachooei, Amir R; Moradi, Ali; Jupiter, Jesse B
2016-05-01
The purpose of this study was to report the long-term outcome and complications of surgically fixated lateral unicondylar distal humerus fractures. Retrospective Review. Two level 1 Trauma Centers, Massachusetts General Hospital and Brigham and Women's Hospital. Between 2002 and 2014, 24 patients treated with open reduction and internal fixation for lateral unicondylar distal humerus fractures (OTA/AO type B1 fractures) were retrospectively reviewed. Open reduction and internal fixation. Union rates, early complications, functional outcome, and the range of elbow motion were evaluated. Disabilities of the arm, shoulder, and hand, Mayo elbow Performance Index, satisfaction, pain scale, and American Shoulder and Elbow Surgeons. The mean age of patients was 46 ± 23 years at the time of surgery. The average final flexion/extension arc of motion was 108°. Reoperations were performed in 9 of 24 elbows after an average 21 ± 31 months. Twenty of the 24 patients were available for the clinical follow-up at an average of 70 months (range: 16-144 months). Disabilities of the arm, shoulder, and hand averaged at 10.8 ± 11.7 points, satisfaction at 9.5 ± 1.2, American Shoulder and Elbow Surgeons score at 88.5 ± 13.3 points at final follow-up. Based on the functional classification proposed by Jupiter, 16 demonstrated good to excellent results, 2 fair and 2 poor result. Outcome of open reduction and internal fixation of isolated lateral column distal humerus fractures can result in high union rates with acceptable outcome scores and high patient satisfaction despite a high reoperation rate. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
40 CFR 600.512-12 - Model year report.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... reports shall be submitted for passenger automobiles and light trucks (as identified in § 600.510). (c...
40 CFR 600.513-08 - Gas Guzzler Tax.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... automobiles sold after December 27, 1991, regardless of the model year of those vehicles. For alcohol dual...
40 CFR 600.513-81 - Gas Guzzler Tax.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... to passenger automobiles exempted from Gas Guzzler Tax assessments by the Energy Tax Act of 1978 and...
40 CFR 600.513-91 - Gas Guzzler Tax.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's Average Carbon... automobiles sold after December 27, 1991, regardless of the model year of those vehicles. For alcohol dual...
Role of SiO2 coating in multiferroic CoCr2O4 nanoparticles
NASA Astrophysics Data System (ADS)
Kamran, M.; Ullah, Asmat; Mehmood, Y.; Nadeem, K.; Krenn, H.
2017-02-01
Effect of silica (SiO2) coating concentration on structural and magnetic properties of multiferroic cobalt chromite (CoCr2O4) nanoparticles have been studied. The nanoparticles with average crystallite size in the range 19 to 28 nm were synthesised by sol-gel method. X-ray diffraction (XRD) analysis has verified the composition of single-phase cubic normal spinel structure of CoCr2O4 nanoparticles. The average crystallite size and cell parameter decreased with increasing SiO2 concentration. TEM image revealed that the shape of nanoparticles was non-spherical. Zero field cooled/field cooled (ZFC/FC) curves revealed that nanoparticles underwent a transition from paramagnetic (PM) state to collinear short-range ferrimagnetic (FiM) state, and this PM-FiM transition temperature decreased from 101 to 95 K with increasing SiO2 concentration or decreasing crystallite size. A conical spin state at Ts = 27 K was also observed for all the samples which decreased with decreasing average crystallite size. Low temperature lock-in transition was also observed in these nanoparticles at 12 K for uncoated nanoparticles which slightly shifted towards low temperature with decreasing average crystallite size. Saturation magnetization (Ms) showed decreasing trend with increasing SiO2 concentration, which was due to decrease in average crystallite size of nanoparticles and enhanced surface disorder in smaller nanoparticles. The temperature dependent AC-susceptibility also showed the decrease in the transition temperature (Tc), broadening of the Tc peak and decrease in magnetization with increasing SiO2 concentration or decreasing average crystallite size. In summary, the concentration of SiO2 has significantly affected the structural and magnetic properties of CoCr2O4 nanoparticles.
NASA Astrophysics Data System (ADS)
Yuksel, Heba; Davis, Christopher C.
2006-09-01
Intensity fluctuations at the receiver in free space optical (FSO) communication links lead to a received power variance that depends on the size of the receiver aperture. Increasing the size of the receiver aperture reduces the power variance. This effect of the receiver size on power variance is called aperture averaging. If there were no aperture size limitation at the receiver, then there would be no turbulence-induced scintillation. In practice, there is always a tradeoff between aperture size, transceiver weight, and potential transceiver agility for pointing, acquisition and tracking (PAT) of FSO communication links. We have developed a geometrical simulation model to predict the aperture averaging factor. This model is used to simulate the aperture averaging effect at given range by using a large number of rays, Gaussian as well as uniformly distributed, propagating through simulated turbulence into a circular receiver of varying aperture size. Turbulence is simulated by filling the propagation path with spherical bubbles of varying sizes and refractive index discontinuities statistically distributed according to various models. For each statistical representation of the atmosphere, the three-dimensional trajectory of each ray is analyzed using geometrical optics. These Monte Carlo techniques have proved capable of assessing the aperture averaging effect, in particular, the quantitative expected reduction in intensity fluctuations with increasing aperture diameter. In addition, beam wander results have demonstrated the range-cubed dependence of mean-squared beam wander. An effective turbulence parameter can also be determined by correlating beam wander behavior with the path length.
Tashjian, Robert Z; Erickson, Gregory A; Robins, Richard J; Zhang, Yue; Burks, Robert T; Greis, Patrick E
2017-06-01
The primary purpose of this study was to determine the effect of the preoperative position of the musculotendinous junction (MTJ) on rotator cuff healing after double-row arthroscopic rotator cuff repair. A secondary purpose was to evaluate how tendon length and MTJ position change when the rotator cuff heals. Preoperative and postoperative magnetic resonance imaging (MRI) scans of 42 patients undergoing arthroscopic double-row rotator cuff repair were reviewed. Patients undergoing repairs with other constructs or receiving augmented repairs (platelet-rich fibrin matrix) who had postoperative MRI scans were excluded. Preoperative MRI scans were evaluated for anteroposterior tear size, tendon retraction, tendon length, muscle quality, and MTJ position with respect to the glenoid in the coronal plane. The position of the MTJ was referenced off the glenoid face as either lateral or medial. Postoperative MRI scans were evaluated for healing, tendon length, and MTJ position. Of 42 tears, 36 (86%) healed, with 27 of 31 small to medium tears (87%) and 9 of 11 large to massive tears (82%) healing. Healing occurred in 94% of tears that had a preoperative MTJ lateral to the face of the glenoid but only 56% of tears that had a preoperative MTJ medial to the glenoid face (P = .0135). The measured tendon length increased an average of 14.4 mm in patients whose tears healed compared with shortening by 6.4 mm in patients with tears that did not heal (P < .001). The MTJ lateralized an average of 6.1 mm in patients whose tears healed compared with medializing 1.9 mm in patients whose tears did not heal (P = .026). The overall follow-up period of the study was from April 2005 to September 2014 (113 months). The preoperative MTJ position is predictive of postoperative healing after double-row rotator cuff repair. The position of the MTJ with respect to the glenoid face is a reliable, identifiable marker on MRI scans that can be predictive of healing. Level IV, retrospective review of case series; therapeutic study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Trofimov, A; Sharp, G
Purpose: To investigate the impact of anatomy/setup variations on standard vs. hypofractionated anterolateral pencil beam scanning (PBS) proton therapy for prostate cancer. Methods: Six prostate cancer patients treated with double-scattering proton therapy, who underwent weekly verification CT scans were selected. Implanted fiducials were used for localization, and endorectal balloons for immobilization. New PBS plans using combination of lateral and anterior-oblique (AO) (±35 deg) beams were created. AO beams were added to spare the femoral heads during hypofractionation. Lateral beams delivered 50.4 Gy(RBE) to prostate plus 5-15mm of seminal vesicles and AO beams 28.8 Gy(RBE) to prostate, in 44 fractions. PTVmore » was laterally expanded by 2.5% to account for range uncertainty. No range margins were applied for AO beams, assuming delivery with in-vivo range verification. Field-specific apertures with 1.2cm margin were used. Spot size was ∼9.5mm sigma for 172MeV @isocenter in air. Plans were optimized as single-field-uniform-dose with ∼5% maximum non-uniformity. The planned dose was recomputed on each weekly CT after aligning the fiducials with the simulation CT, scaled and accumulated via deformable image registration. Hypofractionated treatments with 12 and 5 fractions were considered. Equivalent doses were calculated for prostate (α/β= 1.5Gy), bladder and rectum (α/β= 3Gy). Results: The biological equivalent prostate dose was 86.2 and 92.9 Gyeq for the hypofractionation scenarios at 4.32 and 7.35 Gy/fx, respectively. The equivalent prostate D98 was degraded by on average 2.7 Gyeq for standard, and 3.1 and 4.0 Gyeq for the hypofractionated plans after accumulation. Differences between accumulated and planned Dmean/D2/EUD were generally reduced when reducing the number of fractions for bladder and rectum. The average Dmean/D2/EUD differences over all patients and organs-at-risk were 0.74/4.0/9.23, 0.49/3.64/5.51, 0.37/3.21/3.49 Gyeq for 44, 12 and 5 fractions. Conclusion: Hypofractionation makes proton therapy of prostate more susceptible to interfractional motion-induced target dose degradation compared to the standard fractionation.« less
Wei, Guoke; Wang, Jinliang; Chen, Yu
2015-01-01
The enhancement factor (EF) of surface-enhanced Raman scattering (SERS) from two-dimensional (2D) hexagonal silver nanorod (AgNR) arrays were investigated in terms of electromagnetic (EM) mechanism by using the discrete dipole approximation (DDA) method. The dependence of EF on several parameters, i.e., structure, length, excitation wavelength, incident angle and polarization, and gap size has been investigated. "Hotspots" were found distributed in the gaps between adjacent nanorods. Simulations of AgNR arrays of different lengths revealed that increasing the rod length from 374 to 937 nm (aspect ratio from 2.0 to 5.0) generated more "hotspots" but not necessarily increased EF under both 514 and 532 nm excitation. A narrow lateral gap (in the incident plane) was found to result in strong EF, while the dependence of EF on the diagonal gap (out of the incident plane) showed an oscillating behavior. The EF of the array was highly dependent on the angle and polarization of the incident light. The structure of AgNR and the excitation wavelength were also found to affect the EF. The EF of random arrays was stronger than that of an ordered one with the same average gap of 21 nm, which could be explained by the exponential dependence of EF on the lateral gap size. Our results also suggested that absorption rather than extinction or scattering could be a good indicator of EM enhancement. It is expected that the understanding of the dependence of local field enhancement on the structure of the nanoarrays and incident excitations will shine light on the optimal design of efficient SERS substrates and improved performance.
Microbiological water quality in a large irrigation system: El Valle del Yaqui, Sonora México.
Gortáres-Moroyoqui, Pablo; Castro-Espinoza, L; Naranjo, Jaime E; Karpiscak, Martin M; Freitas, Robert J; Gerba, Charles P
2011-01-01
The primary objective of this study was to determine the microbial water quality of a large irrigation system and how this quality varies with respect to canal size, impact of near-by communities, and the travel distance from the source in the El Valle del Yaqui, Sonora, México. In this arid region, 220,000 hectares are irrigated with 80% of the irrigation water being supplied from an extensive irrigation system including three dams on the Yaqui River watershed. The stored water flows to the irrigated fields through two main canal systems (severing the upper and lower Yaqui Valley) and then through smaller lateral canals that deliver the water to the fields. A total of 146 irrigation water samples were collected from 52 sample sites during three sampling events. Not all sites could be accessed on each occasion. All of the samples contained coliform bacteria ranging from 1,140 to 68,670 MPN/100 mL with an arithmetic mean of 11,416. Ninety-eight percent of the samples contained less than 1,000 MPN/100 mL Escherichia coli, with an arithmetic mean of 291 MPN/100 mL. Coliphage were detected in less than 30% of the samples with an arithmetic average equal to 141 PFU/100 mL. Enteroviruses, Cryptosporidium oocysts, and Giardia cysts were also detected in the canal systems. No significant difference was found in the water quality due to canal system (upper or lower Yaqui Valley), canal-size (main vs. lateral), distance from source, and the vicinity of human habitation (presence of various villages and towns along the length of the canals). There was a significant decrease in coliforms (p < 0.011) and E. coli (< 0.022) concentrations as travel distance increased from the City of Obregón.
Hiraishi, Hirotoshi; Kikuchi, Mitsuru; Yoshimura, Yuko; Kitagawa, Sachiko; Hasegawa, Chiaki; Munesue, Toshio; Takesaki, Natsumi; Ono, Yasuki; Takahashi, Tsutomu; Suzuki, Michio; Higashida, Haruhiro; Asada, Minoru; Minabe, Yoshio
2015-03-01
Autism spectrum disorder (ASD) is often described as comprising an unusual brain growth pattern and aberrant brain lateralization. Although it is important to study the pathophysiology of the developing ASD cortex, examples of physiological brain lateralization in young children with ASD have yet to be well examined. Thirty-eight boys with ASD (aged 3-7 years) and 38 typically developing (TD) boys (aged 3-8 years) concentrated on video programs and their brain activities were measured non-invasively. We employed a customized child-sized magnetoencephalography system in which the sensors were located as close to the brain as possible for optimal recording in young children. To produce a credible laterality index of the brain oscillations, we defined two clusters of sensors corresponding to the right and left hemispheres. We focused on the laterality index ([left - right]/[left+right]) of the relative power band in seven frequency bands. The TD group displayed significantly rightward lateralized brain oscillations in the theta-1 frequency bands compared to the ASD group. This is the first study to demonstrate unusual brain lateralization of brain oscillations measured by magnetoencephalography in young children with ASD. © 2014 The Authors. Psychiatry and Clinical Neurosciences © 2014 Japanese Society of Psychiatry and Neurology.
NASA Astrophysics Data System (ADS)
McIntosh, Daniel H.; CANDELS Collaboration
2017-01-01
The premiere HST/WFC3 Treasury program CANDELS (Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey) has produced detailed visual classifications for statistically useful samples of bright (H>24.5mag) galaxies during and after z~2, the epoch of peak galaxy development. By averaging multiple classifications per galaxy that encompass spheroid-only, bulge-dominated, disk-dominated, disk-only, and irregular/peculiar appearances at visible rest-frame wavelengths, we find that 90% of massive (>1e10 Msun) galaxies at 0.6
Sekhon, Harjeet Kaur; Sircar, Keya; Singh, Sanjeet; Jawa, Deepti; Sharma, Priyanka
2014-01-01
Identification is the establishment of identity of an individual. The basis of dental identification is based on the observation that no two individuals can have same dentition. Palatal rugae are irregular, asymmetric ridges of the mucous membrane extending laterally from the incisive papilla and the anterior part of the palatal raphe. The location of palatal rugae inside the oral cavity confers them with stability even when exposed to high temperatures or trauma. Their resistance to trauma and their apparent unique appearance has suggested their use as a tool for forensic identification. To record the biometric characteristics of shape, size, direction, number and position of palatal rugae and analyze whether palatal rugoscopy can be used as a tool for personal identification and for sex determination. A cross-sectional study. The sample consisted of 100 subjects (50 males, 50 females) between 18 and 25 years. Maxillary impressions were made with elastomeric impression material and dental stone was used to make models. The palatal rugae patterns were traced and analyzed with a magnifying hand lens. The biometric characteristics of number, size, shape, and direction were analyzed using Thomaz and Kotz classification (1983). The casts were coded to blind the examiners about the identity of the subjects. Unpaired t-test and one-way ANOVA using SPSS 19.0 statistical program for Windows. The average number of rugae was slightly more in females. Wavy (44.9%) and curved (41.8%) shapes were more prevalent. Maximum number of rugae was found in E quadrant (40.73%). The average size was 9.221 mm. Most rugae were forwardly directed in both groups. This study concluded that rugae pattern are highly individualistic and can be used as a supplementary method for personal identification and sex determination. Further inter-observer and intra-observer variability were not found to be significant, which further validates the use of rugoscopy as a forensic tool.
NASA Astrophysics Data System (ADS)
Schulze, C. S.; Huang, X.; Prohl, C.; Füllert, V.; Rybank, S.; Maddox, S. J.; March, S. D.; Bank, S. R.; Lee, M. L.; Lenz, A.
2016-04-01
The atomic structure and stoichiometry of InAs/InGaAs quantum-dot-in-a-well structures grown on exactly oriented GaP/Si(001) are revealed by cross-sectional scanning tunneling microscopy. An averaged lateral size of 20 nm, heights up to 8 nm, and an In concentration of up to 100% are determined, being quite similar compared with the well-known quantum dots grown on GaAs substrates. Photoluminescence spectra taken from nanostructures of side-by-side grown samples on GaP/Si(001) and GaAs(001) show slightly blue shifted ground-state emission wavelength for growth on GaP/Si(001) with an even higher peak intensity compared with those on GaAs(001). This demonstrates the high potential of GaP/Si(001) templates for integration of III-V optoelectronic components into silicon-based technology.
Impact Tsunami Calculations: Hydrodynamical Simulations vs. Linear Theory
NASA Technical Reports Server (NTRS)
Korycansky, E.; Asphaug, E.; Ward, S. N.
2003-01-01
Tsunamis generated by the impacts of asteroids and comets into the Earth oceans are widely recognized as a potential catastrophic hazard to the Earth s population. Our general conclusion is that linear theory is a reasonably accurate guide to behavior of tsunamis generated by impactors of moderate size, where the initial transient impact cavity is of moderate depth compared to the ocean depth. This is particularly the case for long wavelength waves that propagate fastest and would reach coastlines first. Such tsunamis would be generated in the open ocean by impactors of 300 meters in diameter, which might be expected to strike the Earth once every few thousand years, on the average. Larger impactors produce cavities deep enough to reach the ocean floor; even here, linear theory is applicable if the starting point is chosen at a later phase in the calculation when the impact crater has slumped back to produce a cavity of moderate depth and slope.
Compositional and structural properties of pulsed laser-deposited ZnS:Cr films
NASA Astrophysics Data System (ADS)
Nematollahi, Mohammadreza; Yang, Xiaodong; Seim, Eivind; Vullum, Per Erik; Holmestad, Randi; Gibson, Ursula J.; Reenaas, Turid W.
2016-02-01
We present the properties of Cr-doped zinc sulfide (ZnS:Cr) films deposited on Si(100) by pulsed laser deposition. The films are studied for solar cell applications, and to obtain a high absorption, a high Cr content (2.0-5.0 at.%) is used. It is determined by energy-dispersive X-ray spectroscopy that Cr is relatively uniformly distributed, and that local Cr increases correspond to Zn decreases. The results indicate that most Cr atoms substitute Zn sites. Consistently, electron energy loss and X-ray photoelectron spectroscopy showed that the films contain mainly Cr2+ ions. Structural analysis showed that the films are polycrystalline and textured. The films with ~4 % Cr are mainly grown along the hexagonal [001] direction in wurtzite phase. The average lateral grain size decreases with increasing Cr content, and at a given Cr content, increases with increasing growth temperature.
Dental traumatology: an orphan in pediatric dentistry?
Andreasen, Jens Ove; Lauridsen, Eva; Daugaard-Jensen, Jette
2009-01-01
Traumatic dental injuries are very frequent during childhood and adolescence. In fact, 2 out of 3 children have suffered a traumatic dental injury before adulthood. This fact links dental traumatology to pediatric dentistry. Unfortunately, this is not reflected by active participation by pediatric dentists in acute treatment, follow-up, and research. To examine the status of pediatric dentistry in relation to dental trauma, a publication analysis was undertaken in 1980, 1990, 2000, and 2007 about trauma articles published in 4 pediatric journals: journal of Dentistry for Children, Pediatric Dentistry, The journal of Pedodontics, and the International journal of Pediatric Dentistry. This study shows an average publication rate of trauma articles of approximately 3 percent of all articles published and with no improvement in later decennia. If only clinical studies are considered (leaving out case reports), the publication rate is less than 1 percent--completely out of proportion to the size of the problem dental trauma impose in children.
The strength of friendship ties in proximity sensor data.
Sekara, Vedran; Lehmann, Sune
2014-01-01
Understanding how people interact and socialize is important in many contexts from disease control to urban planning. Datasets that capture this specific aspect of human life have increased in size and availability over the last few years. We have yet to understand, however, to what extent such electronic datasets may serve as a valid proxy for real life social interactions. For an observational dataset, gathered using mobile phones, we analyze the problem of identifying transient and non-important links, as well as how to highlight important social interactions. Applying the Bluetooth signal strength parameter to distinguish between observations, we demonstrate that weak links, compared to strong links, have a lower probability of being observed at later times, while such links-on average-also have lower link-weights and probability of sharing an online friendship. Further, the role of link-strength is investigated in relation to social network properties.
Academic Self-Perception and Its Relationship to Academic Performance
ERIC Educational Resources Information Center
Stringer, Ronald W.; Heath, Nancy
2008-01-01
One hundred and fifty-five students (average age, 10 years 7 months) were initially tested on reading, arithmetic, and academic self-perception. One year later they were tested again. Initial academic scores accounted for a large proportion of the variance in later academic scores. The children's self-perceptions of academic competence accounted…
Minimally invasive (MIS) Tönnis osteotomy- A technical annotation and review of short term results.
Balakumar, Balasubramanian; Racy, Malek; Madan, Sanjeev
2018-03-01
We detail a modified single incision approach to perform the Tonnis triple pelvic osteotomy by a minimally invasive approach. 12 children underwent minimally invasive Tonnis Osteotomy. There were five boys and seven girls in this study group. Average age was 11 years (9-15 years) at the time of surgery. Mean follow-up was 20.5 months (13-39 months). The average preoperative Antero-Posterior (AP) Centre Edge (CE) angle was -8.8° (-38.6°-18°), the average post-operative AP CE angle was 29.7° (25.1°-43.7°). The average preoperative lateral CE angle was -4.7° (-16°-0°), the average postoperative Lateral CE angle was 28.5° (21.3°-37.4°). The Sharp's angle before and after surgery were 55.7° (51.3°-66°) and 32.4° (16.1°-40.1°) respectively. The mean Tönnis angle before and after the osteotomy were 28.86° (19.7°-43.4°) and 6.3° (0.5°-9.4°) respectively. There was one major complication with sciatic nerve palsy which is in the recovery phase on followup and six minor complications including two cases of transient lateral femoral cutaneous nerve injury, two cases of ischial non-union, over granulation of the wound in one case, and metalwork irritation in one case. We have described a minimally invasive Tonnis osteotomy as a viable option based on our results. This technique is recommended for those who are conversant with the traditional pelvicosteotomies.
Measurement of earth pressures on concrete box culverts under highway embankments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, M.Z.; Drumm, E.C.; Bennett, R.M.
1999-07-01
To obtain a better understanding of the stresses acting on cast-in-place concrete box culverts, and to investigate the conditions which resulted in a culvert failure under about 12 meters of backfill, two sections of a new culvert were instrumented. The measured earth pressure distribution was found to depend upon the height of the embankment over the culvert. For low embankment heights (less than one-half the culvert width), the average measured vertical earth pressures, weighted by tributary length, were about 30% greater than the recommended AASHTO pressures. The measured lateral pressures were slightly greater than the AASHTO pressures. As the embankmentmore » height increased, the measured weighted average vertical stress exceeded the AASHTO pressures by about 20%. Lateral pressures which exceeded the vertical pressures were recorded at the bottom of the culvert walls, and small lateral pressures were recorded on the upper locations of the wall. The high lateral pressures at the base of the wall are consistent with the results from finite element analyses with high density (modulus) backfill material placed around the culvert.« less
Thrust vectoring for lateral-directional stability
NASA Technical Reports Server (NTRS)
Peron, Lee R.; Carpenter, Thomas
1992-01-01
The advantages and disadvantages of using thrust vectoring for lateral-directional control and the effects of reducing the tail size of a single-engine aircraft were investigated. The aerodynamic characteristics of the F-16 aircraft were generated by using the Aerodynamic Preliminary Analysis System II panel code. The resulting lateral-directional linear perturbation analysis of a modified F-16 aircraft with various tail sizes and yaw vectoring was performed at several speeds and altitudes to determine the stability and control trends for the aircraft compared to these trends for a baseline aircraft. A study of the paddle-type turning vane thrust vectoring control system as used on the National Aeronautics and Space Administration F/A-18 High Alpha Research Vehicle is also presented.
Three perimeter effects in ferroelectric nanostructures
NASA Astrophysics Data System (ADS)
Ruediger, Andreas; Peter, Frank; Waser, Rainer
2006-03-01
As the lateral size of ferroelectric nanoislands is now well below 50 nm, the question of size effects becomes increasingly relevant. Three independent techniques provided data of pronounced ferroelectric features along the perimeter: impedance spectroscopy [1], piezoelectric force microscopy [2] and pyroelectric current sensing [3]. However, as we can show, all three observations are related to the measurement technique that interferes with the lateral confinement and still there is no direct evidence of a lateral size effect in ferroelectric nanostructures. We discuss some scenarios of further downscaling and possible consequences. [1]M.Dawber, D.J. Jung, J.F. Scott, “Perimeter effect in very small ferroelectrics“,Appl. Phys. Lett. 82, 436 (2003) [2 ]F. Peter, A. Ruediger, R. Dittmann, R. Waser, K. Szot, B. Reichenberg, K. Prume, “Analysis of shape effects on the piezoresponse in ferroelectric nanograins with and without adsorbates”, Applied Physics Letters, 87, 082901 (2005) [3] B.W. Peterson, S. Ducharme, V.M. Fridkin, “Mapping surface Polarization in thin films of the ferroelectric polymer P(VDF-TrFE)”,Ferroelectrics, 304, 51 (2004)
Bunion correction using proximal chevron osteotomy: a single-incision technique.
Sammarco, G J; Russo-Alesi, F G
1998-07-01
Proximal chevron first metatarsal osteotomy with lateral capsulotomy, adductor tenotomy, and binding of the first and second metatarsals was reviewed in 88 consecutive cases. Seventy-two cases in 55 patients are reported, with an average clinical follow-up of 41 months. The hallux valgus angle improved an average of 15 degrees , from 32.0 degrees preoperatively to an average of 17.0 degrees postoperatively. The intermetatarsal I-II angle improved an average of 5.5 degrees, from 15.3 degrees preoperatively to 9.0 degrees postoperatively. The lateral plantar first metatarsal angle did not change. First metatarsal length was decreased by 2.0 mm. Union occurred at an average of 2 months. Sesamoid position improved 49%, from a preoperative average subluxation of 80% to a postoperative average subluxation of 29%. Subjective foot score profiles improved from a preoperative average of 70.1/100 to a postoperative average of 94.4/100 with respect to pain, deformity, motion, disability, and cosmesis. There were 10 patients with complications, including three patients with delayed unions, two with second metatarsal stress fractures, one with hallux varus, two with hallux limitus, one with progressive arthritis, one with cellulitis, and one with hallux elevatus. Eighty-four percent of the patients stated that they would undergo the procedure again without reservation, 9% would proceed with reservation, and 7% would not proceed with surgery again if offered. This technique provides reliable successful long-term results for the treatment of moderate and severe symptomatic bunion, hallux valgus, and metatarsus primus varus.
Making Sense of Continuing and Renewed Class-Size Findings and Interest.
ERIC Educational Resources Information Center
Achilles, C. M.; Finn, J. D.
In this paper, the authors examine several factors related to class size. The purpose of the presentation is to: (1) trace the evolution of class-size research; (2) briefly describe the Student Achievement Ratio (STAR) class-size experiment; (3) summarize the early and the later student outcomes of STAR participants; (4) outline the…
Wind modeling and lateral control for automatic landing
NASA Technical Reports Server (NTRS)
Holley, W. E.; Bryson, A. E., Jr.
1975-01-01
For the purposes of aircraft control system design and analysis, the wind can be characterized by a mean component which varies with height and by turbulent components which are described by the von Karman correlation model. The aircraft aero-dynamic forces and moments depend linearly on uniform and gradient gust components obtained by averaging over the aircraft's length and span. The correlations of the averaged components are then approximated by the outputs of linear shaping filters forced by white noise. The resulting model of the crosswind shear and turbulence effects is used in the design of a lateral control system for the automatic landing of a DC-8 aircraft.
Two-dimensional Lagrangian simulation of suspended sediment
Schoellhamer, David H.
1988-01-01
A two-dimensional laterally averaged model for suspended sediment transport in steady gradually varied flow that is based on the Lagrangian reference frame is presented. The layered Lagrangian transport model (LLTM) for suspended sediment performs laterally averaged concentration. The elevations of nearly horizontal streamlines and the simulation time step are selected to optimize model stability and efficiency. The computational elements are parcels of water that are moved along the streamlines in the Lagrangian sense and are mixed with neighboring parcels. Three applications show that the LLTM can accurately simulate theoretical and empirical nonequilibrium suspended sediment distributions and slug injections of suspended sediment in a laboratory flume.
NASA Astrophysics Data System (ADS)
Whaley, K. B.; Yu, C. F.; Hogg, C. S.; Light, J. C.; Sibener, S. J.
1985-08-01
A detailed investigation of the spatially anisotropic component of the laterally averaged molecular hydrogen/Ag(111) physisorption potential is presented. Experimentally derived rotationally inelastic transition probabilities for H2, D2, and HD, taken as a function of collision energy, are compared with those resulting from close-coupled quantum scattering calculations. These calculations utilize exponential-3 and variable exponent parameterizations of the laterally averaged isotropic potential which reproduce the experimental bound state resonance spectra for p-H2 and o-D2 on Ag(111). Complementary information is obtained by analyzing the magnetic sub-level splittings for physisorbed J = 1 n-H2, using diffractive selective adsorption resonance energies calculated with first order perturbation theory. Theoretical predictions for HD/Ag(111) rotationally mediated selective adsorption resonances are also compared with previously reported experimental results, which show well resolved J-dependent energy shifts resulting in part from the orientational anisotropy of the potential. The results obtained in this study indicate that both the attractive and repulsive parts of the anisotropic potential exhibit only a weak orientation dependence, in agreement with recent theoretical predictions for this system.
NASA Astrophysics Data System (ADS)
Whaley, K. Birgitta; Yu, Chien-fan; Hogg, C. S.; Light, John C.; Sibener, S. J.
1985-10-01
A detailed investigation of the spatially anisotropic component of the laterally averaged molecular hydrogen/Ag(111) physisorption potential is presented. Experimentally derived rotationally inelastic transition probabilities for H2, D2, and HD, taken as a function of collision energy, are compared with those resulting from close-coupled quantum scattering calculations. These calculations utilize exponential-3 and variable exponent parametrizations of the laterally averaged isotropic potential which reproduce the experimental bound state resonance spectra for p-H2 and o-D2 on Ag(111). Complementary information is obtained by analyzing the magnetic sublevel splittings for physisorbed J=1 n-H2, using diffractive selective adsorption resonance energies calculated with first order perturbation theory. Theoretical predictions for HD/Ag(111) rotationally mediated selective adsorption resonances are also compared with previously reported experimental results, which show well resolved J-dependent energy shifts resulting in part from the orientational anisotropy of the potential. The results obtained in this study indicate that both the attractive and repulsive parts of the anisotropic potential exhibit only a weak orientation dependence, in agreement with recent theoretical predictions for this system.
ERIC Educational Resources Information Center
Turgut, Sedat; Temur, Özlem Dogan
2017-01-01
In this research, the effects of using game in mathematics teaching process on academic achievement in Turkey were examined by metaanalysis method. For this purpose, the average effect size value and the average effect size values of the moderator variables (education level, the field of education, game type, implementation period and sample size)…
Effects of epidemic threshold definition on disease spread statistics
NASA Astrophysics Data System (ADS)
Lagorio, C.; Migueles, M. V.; Braunstein, L. A.; López, E.; Macri, P. A.
2009-03-01
We study the statistical properties of SIR epidemics in random networks, when an epidemic is defined as only those SIR propagations that reach or exceed a minimum size sc. Using percolation theory to calculate the average fractional size
Feger, Mark A; Goetschius, John; Love, Hailey; Saliba, Sue A; Hertel, Jay
2015-11-01
The purpose of this systematic review was to assess whether electrical stimulation (ES), when used in conjunction with a standard treatment, can reduce levels of functional impairment, edema, and pain compared to a standard treatment alone, in patients following a lateral ankle sprain. We searched PubMed, CINAHL, SportDiscus, and Medline (OVID) databases through June 2014 using the terms "ankle sprain or ankle sprains or ligament injury or ligamentous injury," and "electric stimulation or electric stimulation or electrotherapy." Our search identified four randomized control trials, of which, neuromuscular ES and high-voltage pulsed stimulation were the only two ES modalities utilized. Effect sizes and 95% confidence intervals (CI) were estimated using Cohen's d for comparison between treatment groups. Three of four effect sizes for function had 95% CI that crossed zero. Twenty-four of the thirty-two effect sizes for edema had 95% CI that crossed zero. All effect sizes for pain had 95% CI that crossed zero. Therefore, the use of ES is not recommended as a means to improve function, reduce edema, or decrease pain in the treatment of acute lateral ankle sprains. Copyright © 2015 Elsevier Ltd. All rights reserved.
An integrated approach to piezoactuator positioning in high-speed atomic force microscope imaging
NASA Astrophysics Data System (ADS)
Yan, Yan; Wu, Ying; Zou, Qingze; Su, Chanmin
2008-07-01
In this paper, an integrated approach to achieve high-speed atomic force microscope (AFM) imaging of large-size samples is proposed, which combines the enhanced inversion-based iterative control technique to drive the piezotube actuator control for lateral x-y axis positioning with the use of a dual-stage piezoactuator for vertical z-axis positioning. High-speed, large-size AFM imaging is challenging because in high-speed lateral scanning of the AFM imaging at large size, large positioning error of the AFM probe relative to the sample can be generated due to the adverse effects—the nonlinear hysteresis and the vibrational dynamics of the piezotube actuator. In addition, vertical precision positioning of the AFM probe is even more challenging (than the lateral scanning) because the desired trajectory (i.e., the sample topography profile) is unknown in general, and the probe positioning is also effected by and sensitive to the probe-sample interaction. The main contribution of this article is the development of an integrated approach that combines advanced control algorithm with an advanced hardware platform. The proposed approach is demonstrated in experiments by imaging a large-size (50μm ) calibration sample at high-speed (50Hz scan rate).
Chevron osteotomy with lateral release and adductor tenotomy for hallux valgus.
Potenza, Vito; Caterini, Roberto; Farsetti, Pasquale; Forconi, Fabrizio; Savarese, Eugenio; Nicoletti, Simone; Ippolito, Ernesto
2009-06-01
Distal chevron osteotomy is a procedure widely performed for the surgical treatment of painful hallux valgus. The risks and benefits of a lateral capsular release and adductor tenotomy combined with chevron osteotomy are still debated. The aim of our study was to report the clinical and radiographic outcomes of this combined procedure in mild and moderate incongruent bunion deformities, with a hallux valgus angle (HVA) up to 40 degrees and an intermetatarsal angle (IMA) up to 20 degrees. Forty-two patients (52 feet) who consecutively underwent chevron osteotomy combined with lateral release and adductor tenotomy were reviewed 24-36 months after surgery. The mean age of the patients was 53.5 (range, 43 to 64) years. All the deformities were mild to moderate, with a mean preoperative value of 28 degrees in the HVA (range, 16 degrees to 40 degrees) and of 13 degrees in the IMA (range, 9 degrees to 20 degrees). At followup, the AOFAS hallux score improved from an average of 46 to an average of 88. The HVA and IMA had an average postoperative decrease respectively of 12 degrees and 6 degrees; lateral sesamoid displacement decreased by a mean of 15%. In no case did we observe infection or nonunion of the osteotomy. In one case, painless avascular necrosis of the first metatarsal head developed. Our short-term results show that distal chevron osteotomy combined with lateral release and adductor tenotomy is a feasible surgical option to address mild to moderate hallux valgus deformity, even with an IM angle between 15 and 20 degrees. Clinical and radiographic outcomes are generally good and patient satisfaction is generally high.
Brar, Abheetinder S; Howell, Stephen M; Hull, Maury L; Mahfouz, Mohamed R
2016-08-01
Kinematically aligned total knee arthroplasty uses a femoral component designed for mechanical alignment (MA) and sets the component in more internal, valgus, and flexion rotation than MA. It is unknown how much kinematic alignment (KA) and flexion of the femoral component reduce the proximal and lateral reach of the trochlea; two reductions that could increase the risk of abnormal patella tracking. We simulated MA and KA of the femoral component in 0° of flexion on 20 3-dimensional bone models of normal femurs. The mechanically and kinematically aligned components were then aligned in 5°, 10°, and 15° of flexion and downsized until the flange contacted the anterior femur. The reductions in the proximal and lateral reach from the proximal point of the trochlea of the MA component set in 0° of flexion were computed. KA at 0° of flexion did not reduce the proximal reach and reduced the lateral reach an average of 3 mm. Flexion of the MA and KA femoral component 5°, 10°, and 15° reduced the proximal reach an average of 4 mm, 8 mm, and 12 mm, respectively (0.8 mm/degree of flexion), and reduced the lateral reach an average of 1 mm and 4 mm regardless of the degree of flexion, respectively. Arthroplasty surgeons and biomechanical engineers striving to optimize patella tracking might consider developing surgical techniques to minimize flexion of the femoral component when performing KA and MA total knee arthroplasty to promote early patella engagement and consider designing a femoral component with a trochlea shaped specifically for KA. Copyright © 2016 Elsevier Inc. All rights reserved.
Chen, Xue-Qiang; Wu, Qun-Feng; Dong, Wei-Qin; Yu, Li-Xin; Li, Xiong-Feng
2018-03-25
To explore clinical effect of modified Chevron osteotomy combined with lateral tissue loosening for the treatment of mild-moderate hallux valgus through internal signal approach. From July 2015 to June 2016, 26 patients with mild-moderate hallux valgus treated with modified Chevron osteotomy combined with lateral tissue loosening through internal signal approach, including 2 males and 24 females aged from 45 to 65 years old with an average of(54.6±4.8) years old;the courses of diseases ranged from 1 to 5 months with an average of (7.5±3.3) months. Hallux valgus angle(HVA), inter metatarsal angle(IMA) were measured at 12 months after operation, and AOFAS score was applied to evaluate clinical effect before and after operation. All incisions were healed at stage I. No incision occurred infection, metatarsal necrosis and recurrence of hallux valgus deformity. Two patients occurred skin numbness caused by musculocutaneous nerve injury. Twenty-six patients were followed up from 6 to 12 months with an average of(9.12±2.06) months. HVA, IMA were(30.01±3.71)°, (14.00±1.50)° before operation and(9.41±4.16)°, (7.00±0.60)° after operation, which had significant difference. There was statistical significance in AOFAS score before operation 54.77±9.59 and after operation 92.73±5.47, and 19 cases obtained excellent results and 7 moderate. Modified Chevron osteotomy combined with full thread headless pressure screw fixation and lateral tissue loosening for the treatment of mild-moderate hallux valgus has advantages of excellent exposure, simple operation, stable fixation, rapid recovery. Akin osteotomy with internal capsulorrhaphy were used with lateral loosening and could recover soft tissue balance between lateral and internal, and could receive satisfied clinical effects. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U
2017-04-01
Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p < 0.001), in TAMx of 53.2% (p < 0.001) and 38.3% (p = 0.002), and in TAMn of 84.4% (p < 0.001) and 68.2% (p < 0.001). Semiquantitative power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.
Genome size variation in the genus Avena.
Yan, Honghai; Martin, Sara L; Bekele, Wubishet A; Latta, Robert G; Diederichsen, Axel; Peng, Yuanying; Tinker, Nicholas A
2016-03-01
Genome size is an indicator of evolutionary distance and a metric for genome characterization. Here, we report accurate estimates of genome size in 99 accessions from 26 species of Avena. We demonstrate that the average genome size of C genome diploid species (2C = 10.26 pg) is 15% larger than that of A genome species (2C = 8.95 pg), and that this difference likely accounts for a progression of size among tetraploid species, where AB < AC < CC (average 2C = 16.76, 18.60, and 21.78 pg, respectively). All accessions from three hexaploid species with the ACD genome configuration had similar genome sizes (average 2C = 25.74 pg). Genome size was mostly consistent within species and in general agreement with current information about evolutionary distance among species. Results also suggest that most of the polyploid species in Avena have experienced genome downsizing in relation to their diploid progenitors. Genome size measurements could provide additional quality control for species identification in germplasm collections, especially in cases where diploid and polyploid species have similar morphology.
The geometry of proliferating dicot cells.
Korn, R W
2001-02-01
The distributions of cell size and cell cycle duration were studied in two-dimensional expanding plant tissues. Plastic imprints of the leaf epidermis of three dicot plants, jade (Crassula argentae), impatiens (Impatiens wallerana), and the common begonia (Begonia semperflorens) were made and cell outlines analysed. The average, standard deviation and coefficient of variance (CV = 100 x standard deviation/average) of cell size were determined with the CV of mother cells less than the CV for daughter cells and both are less than that for all cells. An equation was devised as a simple description of the probability distribution of sizes for all cells of a tissue. Cell cycle durations as measured in arbitrary time units were determined by reconstructing the initial and final sizes of cells and they collectively give the expected asymmetric bell-shaped probability distribution. Given the features of unequal cell division (an average of 11.6% difference in size of daughter cells) and the size variation of dividing cells, it appears that the range of cell size is more critically regulated than the size of a cell at any particular time.
Estimation After a Group Sequential Trial.
Milanzi, Elasma; Molenberghs, Geert; Alonso, Ariel; Kenward, Michael G; Tsiatis, Anastasios A; Davidian, Marie; Verbeke, Geert
2015-10-01
Group sequential trials are one important instance of studies for which the sample size is not fixed a priori but rather takes one of a finite set of pre-specified values, dependent on the observed data. Much work has been devoted to the inferential consequences of this design feature. Molenberghs et al (2012) and Milanzi et al (2012) reviewed and extended the existing literature, focusing on a collection of seemingly disparate, but related, settings, namely completely random sample sizes, group sequential studies with deterministic and random stopping rules, incomplete data, and random cluster sizes. They showed that the ordinary sample average is a viable option for estimation following a group sequential trial, for a wide class of stopping rules and for random outcomes with a distribution in the exponential family. Their results are somewhat surprising in the sense that the sample average is not optimal, and further, there does not exist an optimal, or even, unbiased linear estimator. However, the sample average is asymptotically unbiased, both conditionally upon the observed sample size as well as marginalized over it. By exploiting ignorability they showed that the sample average is the conventional maximum likelihood estimator. They also showed that a conditional maximum likelihood estimator is finite sample unbiased, but is less efficient than the sample average and has the larger mean squared error. Asymptotically, the sample average and the conditional maximum likelihood estimator are equivalent. This previous work is restricted, however, to the situation in which the the random sample size can take only two values, N = n or N = 2 n . In this paper, we consider the more practically useful setting of sample sizes in a the finite set { n 1 , n 2 , …, n L }. It is shown that the sample average is then a justifiable estimator , in the sense that it follows from joint likelihood estimation, and it is consistent and asymptotically unbiased. We also show why simulations can give the false impression of bias in the sample average when considered conditional upon the sample size. The consequence is that no corrections need to be made to estimators following sequential trials. When small-sample bias is of concern, the conditional likelihood estimator provides a relatively straightforward modification to the sample average. Finally, it is shown that classical likelihood-based standard errors and confidence intervals can be applied, obviating the need for technical corrections.
Aronin, C.E. Petrie; Cooper, J.A.; Sefcik, L.S.; Tholpady, S.S.; Ogle, R.C.; Botchwey, E.A.
2008-01-01
A novel scaffold fabrication method utilizing both polymer blend extrusion and gas foaming techniques to control pore size distribution is presented. Seventy five per cent of all pores produced using polymer blend extrusion alone were less than 50 μm. Introducing a gas technique provided better control of pore size distribution, expanding the range from 0-50 to 0-350 μm. Varying sintering time, annealing temperature and foaming pressure also helped reduced the percentage of pore sizes below 50 μm. Scaffolds chosen for in vitro cellular studies had a pore size distribution of 0-300 μm, average pore size 66 ± 17 μm, 0.54 ± 0.02% porosity and 98% interconnectivity, measured by micro computed tomography (microCT) analysis. The ability of the scaffolds to support osteogenic differentiation and cranial defect repair was evaluated by static and dynamic (0.035 ± 0.006 m s-1 terminal velocity) cultivation with dura mater stem cells (DSCs). In vitro studies showed minimal increases in proliferation over 28 days in culture in osteogenic media. Alkaline phosphatase expression remained constant throughout the study. Moderate increases in matrix deposition, as assessed by histochemical staining and microCT analysis, occurred at later time points, days 21 and 28. Although constructs cultured dynamically showed greater mineralization than static conditions, these trends were not significant. It remains unclear whether bioreactor culture of DSCs is advantageous for bone tissue engineering applications. However, these studies show that polycaprolactone (PCL) scaffolds alone, without the addition of other co-polymers or ceramics, support long-term attachment and mineralization of DSCs throughout the entire porous scaffold. PMID:18434267
Treviño, Mario
2014-01-01
Animal choices depend on direct sensory information, but also on the dynamic changes in the magnitude of reward. In visual discrimination tasks, the emergence of lateral biases in the choice record from animals is often described as a behavioral artifact, because these are highly correlated with error rates affecting psychophysical measurements. Here, we hypothesized that biased choices could constitute a robust behavioral strategy to solve discrimination tasks of graded difficulty. We trained mice to swim in a two-alterative visual discrimination task with escape from water as the reward. Their prevalence of making lateral choices increased with stimulus similarity and was present in conditions of high discriminability. While lateralization occurred at the individual level, it was absent, on average, at the population level. Biased choice sequences obeyed the generalized matching law and increased task efficiency when stimulus similarity was high. A mathematical analysis revealed that strongly-biased mice used information from past rewards but not past choices to make their current choices. We also found that the amount of lateralized choices made during the first day of training predicted individual differences in the average learning behavior. This framework provides useful analysis tools to study individualized visual-learning trajectories in mice. PMID:25524257
Kato, Haruhisa; Nakamura, Ayako; Takahashi, Kayori; Kinugasa, Shinichi
2012-01-01
Accurate determination of the intensity-average diameter of polystyrene latex (PS-latex) by dynamic light scattering (DLS) was carried out through extrapolation of both the concentration of PS-latex and the observed scattering angle. Intensity-average diameter and size distribution were reliably determined by asymmetric flow field flow fractionation (AFFFF) using multi-angle light scattering (MALS) with consideration of band broadening in AFFFF separation. The intensity-average diameter determined by DLS and AFFFF-MALS agreed well within the estimated uncertainties, although the size distribution of PS-latex determined by DLS was less reliable in comparison with that determined by AFFFF-MALS. PMID:28348293
Cheong, Jean Ne; Mirhosseini, Hamed; Tan, Chin Ping
2010-06-01
The main objective of the present study was to investigate the effect of polyoxyethylene sorbitan esters and sodium caseinate on physicochemical properties of palm-based functional lipid nanodispersions prepared by the emulsification-evaporation technique. The results indicated that the average droplet size increased significantly (P < 0.05) by increasing the chain length of fatty acids and also by increasing the hydrophile-lipophile balance value. Among the prepared nanodispersions, the nanoemulsion containing Polysorbate 20 showed the smallest average droplet size (202 nm) and narrowest size distribution for tocopherol-tocotrienol nanodispersions, while sodium caseinate-stabilized nanodispersions containing carotenoids had the largest average droplet size (386 nm), thus indicating a greater emulsifying role for Polysorbate 20 compared with sodium caseinate.
Song, Junho; Lucht, Benjamin; Hynynen, Kullervo
2012-07-01
With a change in phased-array configuration from one dimension to two, the electrical impedance of the array elements is substantially increased because of their decreased width (w)-to-thickness (t) ratio. The most common way to compensate for this impedance increase is to employ electrical matching circuits at a high cost of fabrication complexity and effort. In this paper, we introduce a multilayer lateral-mode coupling method for phased-array construction. The direct comparison showed that the electrical impedance of a single-layer transducer driven in thickness mode is 1/(n²(1/(w/t))²) times that of an n-layer lateral mode transducer. A large reduction of the electrical impedance showed the impact and benefit of the lateral-mode coupling method. A one-dimensional linear 32-element 770-kHz imaging array and a 42-element 1.45-MHz high-intensity focused ultrasound (HIFU) phased array were fabricated. The averaged electrical impedances of each element were measured to be 58 Ω at the maximum phase angle of -1.2° for the imaging array and 105 Ω at 0° for the HIFU array. The imaging array had a center frequency of 770 kHz with an averaged -6-dB bandwidth of approximately 52%. For the HIFU array, the averaged maximum surface acoustic intensity was measured to be 32.8 W/cm² before failure.
Vafi, Kourosh; Brandt, Adam
2016-07-19
This paper introduces GHGfrack, an open-source engineering-based model that estimates energy consumption and associated GHG emissions from drilling and hydraulic fracturing operations. We describe verification and calibration of GHGfrack against field data for energy and fuel consumption. We run GHGfrack using data from 6927 wells in Eagle Ford and 4431 wells in Bakken oil fields. The average estimated energy consumption in Eagle Ford wells using lateral hole diameters of 8 (3)/4 and 6 (1)/8 in. are 2.25 and 2.73 TJ/well, respectively. The average estimated energy consumption in Bakken wells using hole diameters of 6 in. for horizontal section is 2.16 TJ/well. We estimate average greenhouse gas (GHG) emissions of 419 and 510 tonne of equivalent CO2 per well (tonne of CO2 eq/well) for the two aforementioned assumed geometries in Eagle Ford, respectively, and 417 tonne of CO2 eq/well for the case of Bakken. These estimates are limited only to GHG emissions from combustion of diesel fuel to supply energy only for rotation of drill string, drilling mud circulation, and fracturing pumps. Sensitivity analysis of the model shows that the top three key variables in driving energy intensity in drilling are the lateral hole diameter, drill pipe internal diameter, and mud flow rate. In hydraulic fracturing, the top three are lateral casing diameter, fracturing fluid volume, and length of the lateral.
NASA Astrophysics Data System (ADS)
Rackow, Thomas; Wesche, Christine; Timmermann, Ralph; Hellmer, Hartmut H.; Juricke, Stephan; Jung, Thomas
2017-04-01
We present a simulation of Antarctic iceberg drift and melting that includes small, medium-sized, and giant tabular icebergs with a realistic size distribution. For the first time, an iceberg model is initialized with a set of nearly 7000 observed iceberg positions and sizes around Antarctica. The study highlights the necessity to account for larger and giant icebergs in order to obtain accurate melt climatologies. We simulate drift and lateral melt using iceberg-draft averaged ocean currents, temperature, and salinity. A new basal melting scheme, originally applied in ice shelf melting studies, uses in situ temperature, salinity, and relative velocities at an iceberg's bottom. Climatology estimates of Antarctic iceberg melting based on simulations of small (≤2.2 km), "small-to-medium-sized" (≤10 km), and small-to-giant icebergs (including icebergs >10 km) exhibit differential characteristics: successive inclusion of larger icebergs leads to a reduced seasonality of the iceberg meltwater flux and a shift of the mass input to the area north of 58°S, while less meltwater is released into the coastal areas. This suggests that estimates of meltwater input solely based on the simulation of small icebergs introduce a systematic meridional bias; they underestimate the northward mass transport and are, thus, closer to the rather crude treatment of iceberg melting as coastal runoff in models without an interactive iceberg model. Future ocean simulations will benefit from the improved meridional distribution of iceberg melt, especially in climate change scenarios where the impact of iceberg melt is likely to increase due to increased calving from the Antarctic ice sheet.
Mahoney, Patrick
2013-08-01
The significance of a gradient in enamel thickness along the human permanent molar row has been debated in the literature. Some attribute increased enamel thickness from first to third molars to greater bite force during chewing. Others argue that thicker third molar enamel relates to a smaller crown size facilitated by a reduced dentin component. Thus, differences in morphology, not function, explains enamel thickness. This study draws on these different interpretive models to assess enamel thickness along the entire human deciduous tooth row. Average enamel thickness (AET), the area and proportion of crown enamel and dentin, and a crown size proxy are calculated for incisors, canines, and molars. Allometric scaling relationships are assessed within each tooth class, and then comparisons are undertaken along the row. Generally, AET was correlated with crown size and scaled with isometry, except for second molars which scaled with positive allometry. Mean AET increased along the row and was greater on molars, where bite forces are reported to be higher. Second molars combined the largest crown size with the thickest enamel and the smallest proportion of dentin, which is consistent with a reduction in the potential for cusp fracture under high bite forces. Resistance to wear may also account for some enamel thickness variation between tooth classes. Dental reduction did not explain the trend in AET from central to lateral incisors, or from first to second molars. The gradient in AET along the deciduous tooth row is partly consistent with a functional interpretation of enamel thickness. Copyright © 2013 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Wilson, Shauna B.; Lonigan, Christopher J.
2010-01-01
Emergent literacy skills are predictive of children's early reading success, and literacy achievement in early schooling declines more rapidly for children who are below-average readers. It is therefore important for teachers to identify accurately children at risk for later reading difficulty so children can be exposed to effective emergent…
Interprosthetic femoral fractures treated with locking plate.
Ebraheim, Nabil; Carroll, Trevor; Moral, Muhammad Z; Lea, Justin; Hirschfeld, Adam; Liu, Jiayong
2014-10-01
Interprosthetic fractures are challenging to manage. Although treatment of femoral fractures around a single implant has been described, there is little literature for treatment of interprosthetic femoral fractures. This study analyses the management and outcomes of 15 patients with interprosthetic femoral fractures treated with locking plates. A retrospective chart review was conducted of 17 patients with interprosthetic femur fracture treated with locking plates from 2002 to 2013. Patient demographics and comorbidities were collected. Preoperatively, patients were classified with the Vancouver or Su classification system. Intraoperative use of bone graft and/or cerclage cables was also examined. Clinical and radiographic outcomes were evaluated for union, time to full weight bearing, return to preinjury level of activity, and pain assessed with visual analog scale (VAS). There were 15 patients with interprosthetic fractures meeting criteria for this study. Average patient age was 80.53 (range, 61-92) years. Bone grafting was used in 23.5% (four of 17) and cerclage cables in 29.4% (five of 17). Patients achieved complete union and return to full weight bearing an average of 4.02 (range, two to six) months later. Average VAS pain score was 1.00 (range, zero to six). All patients returned to their preoperative ambulatory status. Locking plates could achieve satisfactory results for interprosthetic fractures. Considering an individual's fracture type, bone quality and protheses to determine the appropriate plate length and optional use of cerclage and/or bone graft was essential. In this limited sample size, interprosthetic fractures occurred at similar rates at the supracondylar region and diaphysis.
Hides, J A; Lambrecht, G; Stanton, W R; Damann, V
2016-05-01
In microgravity, muscle atrophy occurs in the intrinsic muscles of the spine, with changes also observed in the abdominal muscles. Exercises are undertaken on the International Space Station and on Earth following space flight to remediate these effects. Similar effects have been seen on Earth in prolonged bed rest studies and in people with low back pain (LBP). The aim of this case report was to examine the effects of microgravity, exercise in microgravity and post-flight rehabilitation on the size of the multifidus and antero-lateral abdominal muscles. Ultrasound imaging was used to assess size of the multifidus, transversus abdominis and internal oblique muscles at four time points: pre-flight and after daily rehabilitation on day one (R + 1), day 8 (R + 8) and day 14 (R + 14) after return to Earth (following 6 months in microgravity). Exercises in microgravity maintained multifidus size at L2-L4, however, after spaceflight, size of the multifidus muscle at L5 was reduced, size of the internal oblique muscle was increased and size of transversus abdominis was reduced. Rehabilitation post-space flight resulted in hypertrophy of the multifidus muscle to pre-mission size at the L5 vertebral level and restoration of antero-lateral abdominal muscle size. Exercise in space can prevent loss of spinal intrinsic muscle size. For the multifidus muscles, effectiveness varied at different levels of the spine. Post-mission rehabilitation targeting specific motor control restored muscle balance between the antero-lateral abdominal and multifidus muscles, similar to results from intervention trials for people with LBP. A limitation of the current investigation is that only one astronaut was studied, however, the microgravity model could be valuable as predictable effects on trunk muscles can be induced and interventions evaluated. Level of Evidence Case series.
Femoral sizing in total knee arthroplasty is rotation dependant.
Koninckx, Angelique; Deltour, Arnaud; Thienpont, Emmanuel
2014-12-01
The mismatch between the medio-lateral (ML) and the antero-posterior (AP) size of femoral components in total knee arthroplasty (TKA) has been linked to gender, ethnicity, morphotype and height differences in patients. The hypothesis of this study was that the AP size measurement of a femoral component increases with more external rotation in posterior referencing TKA. During a 2-year period, 201 patients were included in this prospective study. The AP distance of the distal femur was measured with an AP sizer of the Vanguard (Biomet, Warsaw, US) knee system. This AP sizer allows to dial in external rotation by 1° increments and to determine the femoral size with an anterior boom. AP size was noted at 0°, 3° and 5° of external rotation and then compared for ML matching. Antero-posterior and corresponding ML sizes match perfectly for the Vanguard at 0° of external rotation and a central boom position on the anterior femoral surface. Then, the anterior boom was positioned on the antero-lateral cortex and the AP size increased a mean (SD) 1 (0.5) mm. With 3° of external rotation, the AP size increased a mean (SD) 2.3 (0.4) mm and for 5° a mean (SD) 3.8 (0.3) mm (P < 0.05). This increase in AP size resulted in ML overhang of 2.2 (1.2) mm for 3° and 4.8 (2.6) mm for 5° (P < 0.05). Antero-posterior size measurement of the distal femur is determined by the anatomy of the anterior surface with a higher antero-lateral cortex and the amount of external rotation that is dialled in during surgery. Since these parameters vary case per case, the availability of narrow components offers more surgical options to the surgeon and its importance extends beyond the gender aspect allowing different amounts of external rotation to be used without ML overhang. II.
A Probabilistic Wake Vortex Lateral Transport Model Using Data from SFO and DEN
NASA Technical Reports Server (NTRS)
Mellman, George R.; Delisi, Donald P.
2008-01-01
In a previous report, we considered the behavior of the lateral position of vortices as a function of time after vortex formation for Out of Ground Effects (OGE) data for aircraft landing at San Francisco International Airport (SFO). We quantified the spread in lateral position as a function of time and examined how predictable lateral position is under a variety of assumptions. The combination of spread and predictability allowed us to derive probability distribution functions (PDFs) for lateral position given observed crosswind (CW) velocities. In this study, we examine the portability of these PDFs with respect to other landing sites. To this end, we consider OGE data obtained by the Federal Aviation Administration for landings at Denver International Airport (DEN) between 04/05/2006 and 06/03/2006. We consider vortices from both B733 (Boeing 737 models 200-500) and B757 (Boeing 757) aircraft. The data set contains 635 B733 landings and 506 B757 landings. The glide slope altitude for these measurements was 280 m, determined by the average initial vortex observation adjusted for a 3-second delay in the initial observation. The comparable SFO altitude was 158 m. We note that the principal mechanism for lateral transport in the OGE regime is advection by the ambient wind. This implies that a simple crosswind correction may be effective in explaining much of the variation in the lateral transport data. In this study, we again consider the use of ASOS data and average Lidar crosswind data over the vortex altitude range to predict vortex location as a function of time.
NASA Technical Reports Server (NTRS)
Queijo, M J; Wolhart, Walter D
1951-01-01
An investigation was made to determine the effects of vertical-tail size and length and of fuselage shape and length on the static lateral stability characteristics of a model with wing and vertical tails having the quarter-chord lines swept back 45 degrees. The results indicate that the directional instability of the various isolated fuselages was about two-thirds as large as that predicted by classical theory.
Bloecker, Katja; Englund, Martin; Wirth, Wolfgang; Hudelmaier, Martin; Burgkart, Rainer; Frobell, Richard B; Eckstein, Felix
2011-10-28
Meniscus extrusion or hypertrophy may occur in knee osteoarthritis (OA). However, currently no data are available on the position and size of the meniscus in asymptomatic men and women with normal meniscus integrity. Three-dimensional coronal DESSwe MRIs were used to segment and quantitatively measure the size and position of the medial and lateral menisci, and their correlation with sex, height, weight, and tibial plateau area. 102 knees (40 male and 62 female) were drawn from the Osteoarthritis Initiative "non-exposed" reference cohort, including subjects without symptoms, radiographic signs, or risk factors for knee OA. Knees with MRI signs of meniscus lesions were excluded. The tibial plateau area was significantly larger (p < 0.001) in male knees than in female ones (+23% medially; +28% laterally), as was total meniscus surface area (p < 0.001, +20% medially; +26% laterally). Ipsi-compartimental tibial plateau area was more strongly correlated with total meniscus surface area in men (r = .72 medially; r = .62 laterally) and women (r = .67; r = .75) than contra-compartimental or total tibial plateau area, body height or weight. The ratio of meniscus versus tibial plateau area was similar between men and women (p = 0.22 medially; p = 0.72 laterally). Tibial coverage by the meniscus was similar between men and women (50% medially; 58% laterally), but "physiological" medial meniscal extrusion was greater in women (1.83 ± 1.06mm) than in men (1.24mm ± 1.18mm; p = 0.011). These data suggest that meniscus surface area strongly scales with (ipsilateral) tibial plateau area across both sexes, and that tibial coverage by the meniscus is similar between men and women.
2011-01-01
Background Meniscus extrusion or hypertrophy may occur in knee osteoarthritis (OA). However, currently no data are available on the position and size of the meniscus in asymptomatic men and women with normal meniscus integrity. Methods Three-dimensional coronal DESSwe MRIs were used to segment and quantitatively measure the size and position of the medial and lateral menisci, and their correlation with sex, height, weight, and tibial plateau area. 102 knees (40 male and 62 female) were drawn from the Osteoarthritis Initiative "non-exposed" reference cohort, including subjects without symptoms, radiographic signs, or risk factors for knee OA. Knees with MRI signs of meniscus lesions were excluded. Results The tibial plateau area was significantly larger (p < 0.001) in male knees than in female ones (+23% medially; +28% laterally), as was total meniscus surface area (p < 0.001, +20% medially; +26% laterally). Ipsi-compartimental tibial plateau area was more strongly correlated with total meniscus surface area in men (r = .72 medially; r = .62 laterally) and women (r = .67; r = .75) than contra-compartimental or total tibial plateau area, body height or weight. The ratio of meniscus versus tibial plateau area was similar between men and women (p = 0.22 medially; p = 0.72 laterally). Tibial coverage by the meniscus was similar between men and women (50% medially; 58% laterally), but "physiological" medial meniscal extrusion was greater in women (1.83 ± 1.06mm) than in men (1.24mm ± 1.18mm; p = 0.011). Conclusions These data suggest that meniscus surface area strongly scales with (ipsilateral) tibial plateau area across both sexes, and that tibial coverage by the meniscus is similar between men and women. PMID:22035074
... the diameter difference is less than 0.5 mm, but it can be up to 1 mm (0.05 inch). Babies born with different sized ... about. Unequal pupil sizes of more than 1 mm that develop later in life and do NOT ...
3D printing-assisted osteotomy treatment for the malunion of lateral tibial plateau fracture.
Yang, Peng; Du, Di; Zhou, Zhibin; Lu, Nan; Fu, Qiang; Ma, Jun; Zhao, Liangyu; Chen, Aimin
2016-12-01
Osteotomy and internal fixation are usually the most effective way to treat the malunion of lateral tibial plateau fractures, and the accuracy of the osteotomy is still a challenge for surgeons. This is a report of a series of prospectively study of osteotomy treatment for the malunion of lateral plateau fractures with the aid of 3D printing technology. A total of 7 patients with malunion of lateral tibial plateau fractures were enrolled in the study between September 2012 to September 2014 and completed follow up. CT image data were used for 3D reconstruction, and individually 3D printed models were used for accurate measurements and detail osteotomy procedures planning. Under the premeditated operation plan, the osteotomy operations were performed. Patients were invited for follow-up examinations at 2 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months or more. Mean age of the patients was 44 years (range 30-52 years), 3 cases were result of fall injuries, 2 were traffic accidents and 2 were sports injuries. Among the cases, one accompanied with craniocerebra trauma, one with pelvic fracture, one accompanied with both. According to the Schatzker Tibial Plateau classification, the original fracture type were 3 type I, 1 type II and 3 type III. The lateral tibial plateau collapse ranges from 4 mm-12mm, with an average of 9.4mm. All the operations were successfully completed, the average operation time was 77.1min (range 70-90 min), the average intraoperative blood loss was 121.4ml (range 90-180ml), the mean follow-up time was 14.4 months (range 12-18 months), and the average healing time of the osteotomy fragments was 12 weeks (range 11-13 weeks). The difference between preoperative and postoperative Rasmussen scores were statistically significant (P<0.05). All the patients were obtained functional recovery, with no complications. 3D printing technology is helpful to accurately design osteotomy operation, reduce the risk of postoperative deformity, decrease intraoperative blood loss, shorten the operation time, and can effectively improve the treatment effect. Copyright © 2016. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Yang, Yong; Li, Chengshan
2017-10-01
The effect of minor loop size on the magnetic stiffness has not been paid attention to by most researchers in experimental and theoretical studies about the high temperature superconductor (HTS) magnetic levitation system. In this work, we numerically investigate the average magnetic stiffness obtained by the minor loop traverses Δz (or Δx) varying from 0.1 mm to 2 mm in zero field cooling and field cooling regimes, respectively. The approximate values of the magnetic stiffness with zero traverse are obtained using the method of linear extrapolation. Compared with the average magnetic stiffness gained by any minor loop traverse, these approximate values are Not always close to the average magnetic stiffness produced by the smallest size of minor loops. The relative deviation ranges of average magnetic stiffness gained by the usually minor loop traverse (1 or 2 mm) are presented by the ratios of approximate values to average stiffness for different moving processes and two typical cooling conditions. The results show that most of average magnetic stiffness are remarkably influenced by the sizes of minor loop, which indicates that the magnetic stiffness obtained by a single minor loop traverse Δ z or Δ x, for example, 1 or 2 mm, can be generally caused a large deviation.
NASA Astrophysics Data System (ADS)
Fan, Shu-Kai S.; Tsai, Du-Ming; Chuang, Wei-Che
2017-04-01
Solar power has become an attractive alternative source of energy. The multi-crystalline solar cell has been widely accepted in the market because it has a relatively low manufacturing cost. Multi-crystalline solar wafers with larger grain sizes and fewer grain boundaries are higher quality and convert energy more efficiently than mono-crystalline solar cells. In this article, a new image processing method is proposed for assessing the wafer quality. An adaptive segmentation algorithm based on region growing is developed to separate the closed regions of individual grains. Using the proposed method, the shape and size of each grain in the wafer image can be precisely evaluated. Two measures of average grain size are taken from the literature and modified to estimate the average grain size. The resulting average grain size estimate dictates the quality of the crystalline solar wafers and can be considered a viable quantitative indicator of conversion efficiency.
Synthesis of strongly fluorescent molybdenum disulfide nanosheets for cell-targeted labeling.
Wang, Nan; Wei, Fang; Qi, Yuhang; Li, Hongxiang; Lu, Xin; Zhao, Guoqiang; Xu, Qun
2014-11-26
MoS2 nanosheets with polydispersity of the lateral dimensions from natural mineral molybdenite have been prepared in the emulsions microenvironment built by the water/surfactant/CO2 system. The size, thickness, and atomic structure are characterized by transmission electron microscopy (TEM), atomic force microscopy (AFM), and laser-scattering particle size analysis. Meanwhile, by the analysis of photoluminescence spectroscopy and microscope, the MoS2 nanosheets with smaller lateral dimensions exhibit extraordinary photoluminescence properties different from those with relatively larger lateral dimensions. The discovery of the excitation dependent photoluminescence for MoS2 nanosheets makes them potentially of interests for the applications in optoelectronics and biology. Moreover, we demonstrate that the fabricated MoS2 nanosheets can be a nontoxic fluorescent label for cell-targeted labeling application.
Parental investment in the chicken turtle (Deirochelys reticularia)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Congdon, J.D.; Gibbons, J.W.; Greene, J.L.
1983-01-01
Eggs of the chicken turtle (Deirochelys reticularia) were collected in South Carolina from clutches laid in the spring and fall. Clutch size averaged 8.0 eggs (2 SE = 1.6; n = 15) and was weakly correlated with body size of the female. Wet mass of the clutch averaged 72.4 g (2 SE = 11.6, n = 15). There were no significant differences in clutch size or wet mass between spring and fall nesting seasons. Individual eggs laid in the fall (anti x = 10.7 g) were significantly larger than those laid in the spring (anti x = 8.5 g). Fifteenmore » eggs laid in the spring and incubated at 29/sup 0/ +- 2/sup 0/C averaged 152 d to hatching. Hatchling plastron length averaged 24.3 mm, and body wet mass was 6.7 g. Hatchlings (dry mass) contained 27.4% lipid, and the lipids remaining in the neonate at hatching represented 61% of the lipids originally present in the egg. The wet mass of a hatchling is highly correlated with wet mass of the egg. In contrast to clutch size, egg size had a strong positive relationship to body size. A morphological constraint, the width of the pelvic canal, is proposed as having an influence on this relationship. The negative relationship between an optimized egg size and clutch size was not evident, so current optimality models do not appear to be applicable to Deirochelys.« less
NASA Technical Reports Server (NTRS)
Weick, Fred E; Noyes, Richard W
1933-01-01
Three model wings, two with typical slotted ailerons and one with typical frise ailerons, have been tested as part of a general investigation on lateral control devices with particular reference to their effectiveness at high angles of attack, in the 7 by 10 foot wind tunnel of the National Advisory Committee for Aeronautics. Force tests, free-autorotation tests, and forced-rotation tests were made which show the effect of the various ailerons on the general performance of the wing, on the lateral controllability, and on the lateral stability, in general, rolling control at 20 degree angle of attack to plain ailerons of the same size. The adverse yawing moments obtained with the slotted and frise ailerons were, in most cases, slightly smaller than those obtained with plain ailerons of the same size and deflection. However, this improvement was small as compared to the improvement obtainable by the use of suitable differential movements with any of the ailerons, including the plain.
Maintenance of neuronal size gradient in MNTB requires sound-evoked activity.
Weatherstone, Jessica H; Kopp-Scheinpflug, Conny; Pilati, Nadia; Wang, Yuan; Forsythe, Ian D; Rubel, Edwin W; Tempel, Bruce L
2017-02-01
The medial nucleus of the trapezoid body (MNTB) is an important source of inhibition during the computation of sound location. It transmits fast and precisely timed action potentials at high frequencies; this requires an efficient calcium clearance mechanism, in which plasma membrane calcium ATPase 2 (PMCA2) is a key component. Deafwaddler ( dfw 2J ) mutant mice have a null mutation in PMCA2 causing deafness in homozygotes ( dfw 2J / dfw 2J ) and high-frequency hearing loss in heterozygotes (+/ dfw 2J ). Despite the deafness phenotype, no significant differences in MNTB volume or cell number were observed in dfw 2J homozygous mutants, suggesting that PMCA2 is not required for MNTB neuron survival. The MNTB tonotopic axis encodes high to low sound frequencies across the medial to lateral dimension. We discovered a cell size gradient along this axis: lateral neuronal somata are significantly larger than medially located somata. This size gradient is decreased in +/ dfw 2J and absent in dfw 2J / dfw 2J The lack of acoustically driven input suggests that sound-evoked activity is required for maintenance of the cell size gradient. This hypothesis was corroborated by selective elimination of auditory hair cell activity with either hair cell elimination in Pou4f3 DTR mice or inner ear tetrodotoxin (TTX) treatment. The change in soma size was reversible and recovered within 7 days of TTX treatment, suggesting that regulation of the gradient is dependent on synaptic activity and that these changes are plastic rather than permanent. NEW & NOTEWORTHY Neurons of the medial nucleus of the trapezoid body (MNTB) act as fast-spiking inhibitory interneurons within the auditory brain stem. The MNTB is topographically organized, with low sound frequencies encoded laterally and high frequencies medially. We discovered a cell size gradient along this axis: lateral neurons are larger than medial neurons. The absence of this gradient in deaf mice lacking plasma membrane calcium ATPase 2 suggests an activity-dependent, calcium-mediated mechanism that controls neuronal soma size. Copyright © 2017 the American Physiological Society.
The Whole Warps the Sum of Its Parts.
Corbett, Jennifer E
2017-01-01
The efficiency of averaging properties of sets without encoding redundant details is analogous to gestalt proposals that perception is parsimoniously organized as a function of recurrent order in the world. This similarity suggests that grouping and averaging are part of a broader set of strategies allowing the visual system to circumvent capacity limitations. To examine how gestalt grouping affects the manner in which information is averaged and remembered, I compared the error in observers' adjustments of remembered sizes of individual circles in two different mean-size sets defined by similarity, proximity, connectedness, or a common region. Overall, errors were more similar within the same gestalt-defined groups than between different gestalt-defined groups, such that the remembered sizes of individual circles were biased toward the mean size of their respective gestalt-defined groups. These results imply that gestalt grouping facilitates perceptual averaging to minimize the error with which individual items are encoded, thereby optimizing the efficiency of visual short-term memory.
NASA Technical Reports Server (NTRS)
Weick, Fred E; Wenzinger, Carl J
1933-01-01
Tests were made with ordinary ailerons and different sizes of spoilers on rectangular Clark Y wing models with Handley Page tip and full span slots. The tests showed the effect of the control devices on the general performance of the wings as well as on the lateral control and lateral stability characteristics.
Exploring lateral genetic transfer among microbial genomes using TF-IDF.
Cong, Yingnan; Chan, Yao-Ban; Ragan, Mark A
2016-07-25
Many microbes can acquire genetic material from their environment and incorporate it into their genome, a process known as lateral genetic transfer (LGT). Computational approaches have been developed to detect genomic regions of lateral origin, but typically lack sensitivity, ability to distinguish donor from recipient, and scalability to very large datasets. To address these issues we have introduced an alignment-free method based on ideas from document analysis, term frequency-inverse document frequency (TF-IDF). Here we examine the performance of TF-IDF on three empirical datasets: 27 genomes of Escherichia coli and Shigella, 110 genomes of enteric bacteria, and 143 genomes across 12 bacterial and three archaeal phyla. We investigate the effect of k-mer size, gap size and delineation of groups on the inference of genomic regions of lateral origin, finding an interplay among these parameters and sequence divergence. Because TF-IDF identifies donor groups and delineates regions of lateral origin within recipient genomes, aggregating these regions by gene enables us to explore, for the first time, the mosaic nature of lateral genes including the multiplicity of biological sources, ancestry of transfer and over-writing by subsequent transfers. We carry out Gene Ontology enrichment tests to investigate which biological processes are potentially affected by LGT.
NASA Astrophysics Data System (ADS)
Roberts, N. J.; Evans, S. G.
2009-12-01
Gigantic (> 1 Gm3) landslides are high-magnitude, low-frequency extremes of mass movements. They are important factors in topographic evolution and hazard in mountain regions due to their magnitude. However, few examples exist for study because of their infrequency. Consequently, controls on the location and size gigantic landslides remain poorly understood. Re-examination of the Seymareh (Saidmarreh) rock avalanche, Zagros fold-thrust belt, shows it to be the largest sub-aerial landslide on Earth (initial failure volume 38 Gm3), thus representing the upper magnitude limit for terrestrial landslides. Detailed examination of the source area (including orbital remote sensing, geotechnical investigation and structural mapping) provides new insights into controls on the size and mobility of gigantic landslides. The gigantic Early Holocene rockslide initiated on the northeast limb of Kabir Kuh, the largest anticline in the Zagros fold-thrust belt, and involved the simultaneous failure of a rock mass measuring 15 km along strike. The rockslide transformed into a rock avalanche that ran-out 19.0 km, filling two adjacent valleys and overtopping an intervening low mountain ridge. The failure involved 220 m of competent jointed limestone (Asmari Formation) underlain by 580 m of weaker mudrock-dominated units. Geologic structure, geomechanical strength and topography of the source slope strongly controlled failure initiation. Extreme landslide dimensions resulted in part from extensive uniform pre-failure stability, produced by structural and topographic features related to the large scale of the Kabir Kuh anticline. High continuity bedding planes determined the large lateral extent along strike. Bedding normal joints, the breached nature of the anticline and fluvial undercutting at the slope toe accommodated expansive lateral, headscarp and toe release, respectively, necessary for extensive failure. Geomechanically weak units at depth aided the penetration of the failure surface into the source slope while low bedding dip (ca. 19°) allowed kinematic freedom of a particularly thick sequence to move downslope. Prevention of gradual rockmass removal by smaller-magnitude, more frequent denudation ensured its preservation for later simultaneous failure. The overall failure surface (11°) cut across weaker beds and finally breached the Asmari carapace by break-out at the base of the source slope. Relative relief of the source slope on Kabir Kuh was modest (1350 m on average) indicating that uniform structural and topographic conditions along strike, shallow bedding dips, and the geomechnical properties of the source rock mass were more important in determining the magnitude of the landslide that forms the upper magnitude limit for subaerial landslides.
Geological factors affecting CO2 plume distribution
Frailey, S.M.; Leetaru, H.
2009-01-01
Understanding the lateral extent of a CO2 plume has important implications with regards to buying/leasing pore volume rights, defining the area of review for an injection permit, determining the extent of an MMV plan, and managing basin-scale sequestration from multiple injection sites. The vertical and lateral distribution of CO2 has implications with regards to estimating CO2 storage volume at a specific site and the pore pressure below the caprock. Geologic and flow characteristics such as effective permeability and porosity, capillary pressure, lateral and vertical permeability anisotropy, geologic structure, and thickness all influence and affect the plume distribution to varying degrees. Depending on the variations in these parameters one may dominate the shape and size of the plume. Additionally, these parameters do not necessarily act independently. A comparison of viscous and gravity forces will determine the degree of vertical and lateral flow. However, this is dependent on formation thickness. For example in a thick zone with injection near the base, the CO2 moves radially from the well but will slow at greater radii and vertical movement will dominate. Generally the CO2 plume will not appreciably move laterally until the caprock or a relatively low permeability interval is contacted by the CO2. Conversely, in a relatively thin zone with the injection interval over nearly the entire zone, near the wellbore the CO2 will be distributed over the entire vertical component and will move laterally much further with minimal vertical movement. Assuming no geologic structure, injecting into a thin zone or into a thick zone immediately under a caprock will result in a larger plume size. With a geologic structure such as an anticline, CO2 plume size may be restricted and injection immediately below the caprock may have less lateral plume growth because the structure will induce downward vertical movement of the CO2 until the outer edge of the plume reaches a spill point within the structure. ?? 2009 Elsevier Ltd. All rights reserved.
TX18: Cognitive Workload and Fatigue Study
2012-09-01
beverages (e.g., coffee , tea, cola, etc.)? Yes No On average, how many caffeinated beverages do you consume in a DAY? ________ On average, how...Not like me at all 5. I have been obsessed with a certain idea or project for a short time but later lost interest.* Very much like me
Code of Federal Regulations, 2011 CFR
2011-07-01
... MOTOR VEHICLES Fuel Economy Regulations for Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer... will be calculated to the nearest 0.1 mpg for the categories of automobiles identified in this section...
ERIC Educational Resources Information Center
Blanchard, Ray; And Others
1995-01-01
Examined the hypothesis that male homosexuals have a greater than average proportion of male siblings and a later than average birth order, by comparing a group of prehomosexual boys (individuals exhibiting cross-gender behaviors) and homosexual adolescents with a control group. Both predicted results were confirmed. (MDM)
Wills, Andrew K; Strand, Bjørn Heine; Glavin, Kari; Silverwood, Richard J; Hovengen, Ragnhild
2016-04-08
Regression models are widely used to link serial measures of anthropometric size or changes in size to a later outcome. Different parameterisations of these models enable one to target different questions about the effect of growth, however, their interpretation can be challenging. Our objective was to formulate and classify several sets of parameterisations by their underlying growth pattern contrast, and to discuss their utility using an expository example. We describe and classify five sets of model parameterisations in accordance with their underlying growth pattern contrast (conditional growth; being bigger v being smaller; becoming bigger and staying bigger; growing faster v being bigger; becoming and staying bigger versus being bigger). The contrasts are estimated by including different sets of repeated measures of size and changes in size in a regression model. We illustrate these models in the setting of linking infant growth (measured on 6 occasions: birth, 6 weeks, 3, 6, 12 and 24 months) in weight-for-height-for-age z-scores to later childhood overweight at 8y using complete cases from the Norwegian Childhood Growth study (n = 900). In our expository example, conditional growth during all periods, becoming bigger in any interval and staying bigger through infancy, and being bigger from birth were all associated with higher odds of later overweight. The highest odds of later overweight occurred for individuals who experienced high conditional growth or became bigger in the 3 to 6 month period and stayed bigger, and those who were bigger from birth to 24 months. Comparisons between periods and between growth patterns require large sample sizes and need to consider how to scale associations to make comparisons fair; with respect to the latter, we show one approach. Studies interested in detrimental growth patterns may gain extra insight from reporting several sets of growth pattern contrasts, and hence an approach that incorporates several sets of model parameterisations. Co-efficients from these models require careful interpretation, taking account of the other variables that are conditioned on.
Fallesen, Peter
2013-12-01
Individuals who spent time in foster care as children fare on average worse than non-placed peers in early adult life. Recent research on the effect of foster care placement on early adult life outcomes provides mixed evidence. Some studies suggest negative effects of foster care placement on early adult outcomes, others find null effects. This study shows that differences in the average duration of foster care stays explain parts of these discordant findings and then test how foster care duration shapes later life outcomes using administrative data on 7220 children. The children experienced different average durations of foster care because of differences in exposure to a reform. Later born cohorts spent on average 3 months longer in foster care than earlier born cohorts. Isolating exogenous variation in duration of foster care, the study finds positive effects of increased duration of foster care on income and labor market participation. Copyright © 2013 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.
Analysis of 3D strain in the human medial meniscus.
Kolaczek, S; Hewison, C; Caterine, S; Ragbar, M X; Getgood, A; Gordon, K D
2016-10-01
This study presents a method to evaluate three-dimensional strain in meniscal tissue using medical imaging. Strain is calculated by tracking small teflon markers implanted within the meniscal tissue using computed tomography imaging. The results are presented for strains in the middle and posterior third of the medial menisci of 10 human cadaveric knees, under simulated physiologically relevant loading. In the middle position, an average compressive strain of 3.4% was found in the medial-lateral direction, and average tensile strains of 1.4% and 3.5% were found in the anterior-posterior and superior-inferior directions respectively at 5° of knee flexion with an applied load of 1× body weight. In the posterior position, under the same conditions, average compressive strains of 2.2% and 6.3% were found in the medial-lateral and superior-inferior directions respectively, and an average tensile strain of 3.8% was found in the anterior-posterior direction. No statistically significant difference between strain in the middle or posterior of the meniscus or between the global strains is uncovered. Copyright © 2016 Elsevier Ltd. All rights reserved.
EEG and Eye Tracking Signatures of Target Encoding during Structured Visual Search
Brouwer, Anne-Marie; Hogervorst, Maarten A.; Oudejans, Bob; Ries, Anthony J.; Touryan, Jonathan
2017-01-01
EEG and eye tracking variables are potential sources of information about the underlying processes of target detection and storage during visual search. Fixation duration, pupil size and event related potentials (ERPs) locked to the onset of fixation or saccade (saccade-related potentials, SRPs) have been reported to differ dependent on whether a target or a non-target is currently fixated. Here we focus on the question of whether these variables also differ between targets that are subsequently reported (hits) and targets that are not (misses). Observers were asked to scan 15 locations that were consecutively highlighted for 1 s in pseudo-random order. Highlighted locations displayed either a target or a non-target stimulus with two, three or four targets per trial. After scanning, participants indicated which locations had displayed a target. To induce memory encoding failures, participants concurrently performed an aurally presented math task (high load condition). In a low load condition, participants ignored the math task. As expected, more targets were missed in the high compared with the low load condition. For both conditions, eye tracking features distinguished better between hits and misses than between targets and non-targets (with larger pupil size and shorter fixations for missed compared with correctly encoded targets). In contrast, SRP features distinguished better between targets and non-targets than between hits and misses (with average SRPs showing larger P300 waveforms for targets than for non-targets). Single trial classification results were consistent with these averages. This work suggests complementary contributions of eye and EEG measures in potential applications to support search and detect tasks. SRPs may be useful to monitor what objects are relevant to an observer, and eye variables may indicate whether the observer should be reminded of them later. PMID:28559807
Human Visuospatial Updating After Passive Translations In Three-Dimensional Space
Klier, Eliana M.; Hess, Bernhard J. M.; Angelaki, Dora E.
2013-01-01
To maintain a stable representation of the visual environment as we move, the brain must update the locations of targets in space using extra-retinal signals. Humans can accurately update after intervening active whole-body translations. But can they also update for passive translations (i.e., without efference copy signals of an outgoing motor command)? We asked six head-fixed subjects to remember the location of a briefly flashed target (five possible targets were located at depths of 23, 33, 43, 63 and 150cm in front of the cyclopean eye) as they moved 10cm left, right, up, down, forward or backward, while fixating a head-fixed target at 53cm. After the movement, the subjects made a saccade to the remembered location of the flash with a combination of version and vergence eye movements. We computed an updating ratio where 0 indicates no updating and 1 indicates perfect updating. For lateral and vertical whole-body motion, where updating performance is judged by the size of the version movement, the updating ratios were similar for leftward and rightward translations, averaging 0.84±0.28 (mean±SD), as compared to 0.51±0.33 for downward and 1.05±0.50 for upward translations. For forward/backward movements, where updating performance is judged by the size of the vergence movement, the average updating ratio was 1.12±0.45. Updating ratios tended to be larger for far targets than near targets, although both intra- and inter-subject variabilities were smallest for near targets. Thus, in addition to self-generated movements, extra-retinal signals involving otolith and proprioceptive cues can also be used for spatial constancy. PMID:18256164
Overview of breast cancer in Malaysian women: a problem with late diagnosis.
Hisham, Abdullah N; Yip, Cheng-Har
2004-04-01
Breast cancer is the most common cancer among Malaysian women. There is a marked geographical difference in the worldwide incidence of breast cancer, with a higher incidence in developed countries compared to developing countries. From 1998 to 2001, new cases of breast cancer presenting to the breast clinics at Hospital Kuala Lumpur and University Malaya Medical Centre, Malaysia, were reviewed; the race, age and stage at presentation were analysed. Of 774 cases seen in Hospital Kuala Lumpur, only 5.2% (40/774) were impalpable breast cancers diagnosed on mammography. The prevalent age group was 40 to 49 years, and the median age was 50 years. The average size of the tumour was 5.4 cm in diameter. Malay women appear to have larger tumours and a later stage at presentation than other ethnic groups; 50% to 60% were in late stages (Stages 3 and 4). During the same period, 752 new cases of breast cancer were seen in the University Malaya Medical Centre. The average tumour size was 4.2 cm, and 30% to 40% were in late stages. The age incidence was similar. The delay in presentation of breast cancer was attributed to a strong belief in traditional medicine, the negative perception of the disease, poverty and poor education, coupled with fear and denial. A prospective, population-based study is required to determine the demographic pattern of breast cancer and the factors delaying presentation. These findings will have important implications in future programmes to promote the early detection of breast cancer, as well as in understanding geographical as well as racial variations in the incidence of breast cancer.
Pape, D; Adam, F; Rupp, S; Seil, R; Kohn, D
2004-02-01
In high tibial closing-wedge osteotomies (HTO), closure of an osteotomy gap after resection of a bony wedge can be associated with a fissure of the medial cortex of the tibial head (MCT). The effect of a broken MCT on the recurrence of varus deformity is disputed. In this study, serial roentgen stereometric analysis (RSA) was used to determine the fixation stability of a rigid internal "L" plate after HTO. Full weight lower limb radiographs were used to determine the sagittal alignment in patients with varying degrees of varus malalignment and correction over time. Forty-two patients with varus gonarthrosis stage I-III (Ahlback) were treated with HTO and internal fixation with an L-shaped rigid plate. Patients were followed by serial RSA, conventional radiographs, and clinical evaluation (Hospital of Special Surgery score) over a 12-month period. In 19 of 42 successive patients, an average wedge size of 6.9 degrees was resected leaving the MCT intact (group 1). In 23 of 42 of patients, the MCT was unintentionally fissured during surgery when an average 10.3 degrees -wedge was resected (group 2). In group 2, RSA revealed a fivefold increase in lateral displacement of the distal tibial segment within 3 weeks after HTO. Twelve weeks after HTO, translations between tibial segments were below the accuracy of the RSA setup in the majority of patients. Group 1 patients demonstrated a higher initial fixation stability, less occurrence of varus deformity, and a higher HSS score compared to patients with larger wedge sizes and frequent fracture of the MCT (group 2). Before bone healing is achieved, the integrity of the MCT plays a crucial role for the clinical and radiological outcome after HTO.
NASA Astrophysics Data System (ADS)
Shekar, Yamini
This research investigates the nano-scale pore structure of cementitious mortars undergoing delayed ettringite formation (DEF) using small angle x-ray scattering (SAXS). DEF has been known to cause expansion and cracking during later ages (around 4000 days) in concrete that has been heat cured at temperatures of 70°C or above. Though DEF normally occurs in heat cured concrete, mass cured concrete can also experience DEF. Large crystalline pressures result in smaller pore sizes. The objectives of this research are: (1) to investigate why some samples expand early than later expansion, (2) to evaluate the effects of curing conditions and pore size distributions at high temperatures, and (3) to assess the evolution of the pore size distributions over time. The most important outcome of the research is the pore sizes obtained from SAXS were used in the development of a 3-stage model. From the data obtained, the pore sizes increase in stage 1 due to initial ettringite formation and in turn filling up the smallest pores. Once the critical pore size threshold is reached (around 20nm) stage 2 is formed due to cracking which tends to decrease in the pore sizes. Finally, in stage 3, the cracking continues, therefore increasing in the pore size.
Time and size resolved Measurement of Mass Concentration at an Urban Site
NASA Astrophysics Data System (ADS)
Karg, E.; Ferron, G. A.; Heyder, J.
2003-04-01
Time- and size-resolved measurements of ambient particles are necessary for modelling of atmospheric particle transport, the interpretation of particulate pollution events and the estimation of particle deposition in the human lungs. In the size range 0.01 - 2 µm time- and size-resolved data are obtained from differential mobility and optical particle counter measurements and from gravimetric filter analyses on a daily basis (PM2.5). By comparison of the time averaged and size integrated particle volume concentration with PM2.5 data, an average density of ambient particles can be estimated. Using this density, the number concentration data can be converted in time- and size-resolved mass concentration. Such measurements were carried out at a Munich downtown crossroads. The spectra were integrated in the size ranges 10 - 100 nm, 100 - 500 nm and 500 - 2000 nm. Particles in these ranges are named ultrafine, fine and coarse particles. These ranges roughly represent freshly emitted particles, aged/accumulated particles and particles entrained by erosive processes. An average number concentration of 80000 1/cm3 (s.d. 67%), a particle volume concentration of 53 µm3/cm3 (s.d. 76%) and a PM2.5 mass concentration of 27 µg/m3 was found. These particle volume- and PM2.5 data imply an average density of 0.51 g/cm3. Average number concentration showed 95.3%, 4.7% and 0.006% of the total particle concentration in the size ranges mentioned above. Mass concentration was 14.7%, 80.2% and 5.1% of the total, assuming the average density to be valid for all particles. The variability in mass concentration was 94%, 75% and 33% for the three size ranges. Nearly all ambient particles were in the ultrafine size range, whereas most of the mass concentration was in the fine size range. However, a considerable mass fraction of nearly 15% was found in the ultrafine size range. As the sampling site was close to the road and traffic emissions were the major source of the particles, 1) the density was very low due to agglomerated and porous structures of freshly emitted combustion particles and 2) the variability was highest in the ultrafine range, obviously correlated to traffic activity and lowest in the micron size range. In conclusion, almost all ambient particles were ultrafine particles, whereas most of the particle mass was associated with fine particles. Nevertheless, a considerable mass fraction was found in the ultrafine size range. These particles had a very low density so that they can be considered as agglomerated and porous particles emitted from vehicles passing the crossroads. Therefore they showed a much higher variation in mass concentration than the fine and coarse particles.
Electron Scattering at Surfaces of Epitaxial Metal Layers
NASA Astrophysics Data System (ADS)
Chawla, Jasmeet Singh
In the field of electron transport in metal films and wires, the 'size effect' refers to the increase in the resistivity of the films and wires as their critical dimensions (thickness of film, width and height of wires) approach or become less than the electron mean free path lambda, which is, for example, 39 nm for bulk copper at room temperature. This size-effect is currently of great concern to the semiconductor industry because the continued downscaling of feature sizes has already lead to Cu interconnect wires in this size effect regime, with a reported 2.5 times higher resistivity for 40 nm wide Cu wires than for bulk Cu. Silver is a possible alternate material for interconnect wires and titanium nitride is proposed as a gate metal in novel field-effect-transistors. Therefore, it is important to develop an understanding of how the growth, the surface morphology, and the microstructure of ultrathin (few nanometers) Cu, Ag and TiN layers affect their electrical properties. This dissertation aims to advance the scientific knowledge of electron scattering at surfaces (external surfaces and grain boundaries), that are, the primary reasons for the size-effect in metal conductors. The effect of surface and grain boundary scattering on the resistivity of Cu thin films and nanowires is separately quantified using (i) in situ transport measurements on single-crystal, atomically smooth Cu(001) layers, (ii) textured polycrystalline Cu(111) layers and patterned wires with independently varying grain size, thickness and line width, and (iii) in situ grown interfaces including Cu-Ta, Cu-MgO, Cu-vacuum and Cu-oxygen. In addition, the electron surface scattering is also measured in situ for single-crystal Ag(001), (111) twinned epitaxial Ag(001), and single-crystal TiN(001) layers. Cu(001), Ag(001), and TiN(001) layers with a minimum continuous thickness of 4, 3.5 and 1.8 nm, respectively, are grown by ultra-high vacuum magnetron sputter deposition on MgO(001) substrates with and without thin epitaxial TiN(001) wetting layers and are studied for structure, crystalline quality, surface morphology, density and composition by a combination of x-ray diffraction theta-2theta scans, o-rocking curves, pole figures, reciprocal space mapping, Rutherford backscattering, x-ray reflectometry and transmission electron microscopy. The TiN(001) surface suppresses Cu and Ag dewetting, yielding lower defect density, no twinning, and smaller surface roughness than if grown on MgO(001). Textured polycrystalline Cu(111) layers 25-50-nm-thick are deposited on a stack of 7.5-nm-Ta on SiO2/Si(001), and subsequent in situ annealing at 350°C followed by sputter etching in Ar plasma yields Cu layers with independently variable thickness and grain size. Cu nanowires, 75 to 350 nm wide, are fabricated from Cu layers with different average grain size using a subtractive patterning process. In situ electron transport measurements at room temperature in vacuum and at 77 K in liquid nitrogen for single-crystal Cu and Ag layers is consistent with the Fuchs-Sondheimer (FS) model and indicates specular scattering at the metal-vacuum boundary with an average specularity parameter p = 0.8 and 0.6, respectively. In contrast, layers measured ex situ show diffuse surface scattering due to sub-monolayer oxidation. Also, addition of Ta atoms on Cu(001) surface perturbs the smooth interface potential and results in completely diffuse scattering at the Cu-Ta interface, and in turn, a higher resistivity of single-crystal Cu layers. In situ exposure of Cu(001) layers to O2 between 10 -3 and 105 Pa-s results in a sequential increase, decrease and increase of the electrical resistance which is attributed to specular surface scattering for clean Cu(001) and for surfaces with a complete adsorbed monolayer, but diffuse scattering at partial coverage and after chemical oxidation. Electron transport measurements for polycrystalline Cu layers and wires show a 10-15% and 7-9% decrease in resistivity, respectively, when increasing the average lateral grain size by a factor of 1.8. The maximum resistivity decrease that can be achieved by increasing the grain size of polycrystalline Cu layers with an average grain size approximately ˜2.5x the layer thickness is 20-26%.
Galambos, Nancy L; Vargas Lascano, Dayuma I; Howard, Andrea L; Maggs, Jennifer L
2013-01-01
This study tracked change over time in sleep quantity, disturbance, and timing, and sleep's covariations with living situation, stress, social support, alcohol use, and grade point average (GPA) across four years of university in 186 Canadian students. Women slept longer as they moved through university, and men slept less; rise times were later each year. Students reported sleeping fewer hours, more sleep disturbances, and later rise times during years with higher stress. In years when students lived away from home, they reported more sleep disturbances, later bedtimes, and later rise times. Living on campus was associated with later bedtimes and rise times. Alcohol use was higher and GPA was lower when bedtimes were later. The implications of these observed patterns for understanding the correlates and consequences of university students' sleep are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charles, P. H., E-mail: p.charles@qut.edu.au; Crowe, S. B.; Langton, C. M.
Purpose: This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. Methods: A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated intomore » additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. Results: According to the practical definition established in this project, field sizes ≤15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤12 mm. Source occlusion also caused a large change in OPF for field sizes ≤8 mm. Based on the results of this study, field sizes ≤12 mm were considered to be theoretically very small for 6 MV beams. Conclusions: Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least ≤12 mm and more conservatively≤15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection.« less
Charles, P H; Cranmer-Sargison, G; Thwaites, D I; Crowe, S B; Kairn, T; Knight, R T; Kenny, J; Langton, C M; Trapp, J V
2014-04-01
This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. According to the practical definition established in this project, field sizes ≤ 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤ 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤ 12 mm. Source occlusion also caused a large change in OPF for field sizes ≤ 8 mm. Based on the results of this study, field sizes ≤ 12 mm were considered to be theoretically very small for 6 MV beams. Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least ≤ 12 mm and more conservatively ≤ 15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection. © 2014 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Yu, Min-Feng
A new tool capable of three-dimensional manipulation and measurement of the mechanics of nanometer-sized materials inside a scanning electron microscopy is developed and demonstrated. The design and function of this home-built SEM nanomanipulator is explained. The first free-space manipulation of carbon nanotubes is presented. The tensile strength and the breaking mechanism of individual multi-walled carbon nanotubes (MWCNT) and single wall carbon nanotube (SWCNT) ropes are measured using the nanomanipulator, and from the data set the stress-strain relationship is determined. The results indicate that carbon nanotubes have remarkably high tensile strength values, about 50 GPa. The shear strength measurement of sliding nested shells in individual MWCNTs is also achieved for the first time. The experiment provides a new way to directly study the nano-scale interaction involved in the motion of a nanobearing. In a separate work, atomic force microscopy is used to study the lateral deformability of individual MWCNTs. The average force provided by the tapping tip in tapping mode AFM is investigated by both simulation and experiment. An imaging procedure for controlling the average tapping force is developed and is used to study the deformability of carbon nanotubes. The stability of different structures of carbon nanotube is also experimentally studied.
Dirk, Shawn M.; Cicotte, Kirsten Nicole; Wheeler, David R.; Benko, David A.
2015-08-11
A method including reducing a particle size of lignin particles to an average particle size less than 40 nanometers; after reducing the particle size, combining the lignin particles with a polymeric material; and forming a structure of the combination. A method including exposing lignin to a diazonium precursor including a functional group; modifying the lignin by introducing the functional group to the lignin; and combining the modified lignin with a polymeric material to form a composite. An apparatus including a composite of a polymer and lignin wherein the lignin has an average particle size less than 100 micrometers.
Zeming, Kerwin Kwek; Salafi, Thoriq; Chen, Chia-Hung; Zhang, Yong
2016-01-01
Deterministic lateral displacement (DLD) method for particle separation in microfluidic devices has been extensively used for particle separation in recent years due to its high resolution and robust separation. DLD has shown versatility for a wide spectrum of applications for sorting of micro particles such as parasites, blood cells to bacteria and DNA. DLD model is designed for spherical particles and efficient separation of blood cells is challenging due to non-uniform shape and size. Moreover, separation in sub-micron regime requires the gap size of DLD systems to be reduced which exponentially increases the device resistance, resulting in greatly reduced throughput. This paper shows how simple application of asymmetrical DLD gap-size by changing the ratio of lateral-gap (GL) to downstream-gap (GD) enables efficient separation of RBCs without greatly restricting throughput. This method reduces the need for challenging fabrication of DLD pillars and provides new insight to the current DLD model. The separation shows an increase in DLD critical diameter resolution (separate smaller particles) and increase selectivity for non-spherical RBCs. The RBCs separate better as compared to standard DLD model with symmetrical gap sizes. This method can be applied to separate non-spherical bacteria or sub-micron particles to enhance throughput and DLD resolution. PMID:26961061
Zeming, Kerwin Kwek; Salafi, Thoriq; Chen, Chia-Hung; Zhang, Yong
2016-03-10
Deterministic lateral displacement (DLD) method for particle separation in microfluidic devices has been extensively used for particle separation in recent years due to its high resolution and robust separation. DLD has shown versatility for a wide spectrum of applications for sorting of micro particles such as parasites, blood cells to bacteria and DNA. DLD model is designed for spherical particles and efficient separation of blood cells is challenging due to non-uniform shape and size. Moreover, separation in sub-micron regime requires the gap size of DLD systems to be reduced which exponentially increases the device resistance, resulting in greatly reduced throughput. This paper shows how simple application of asymmetrical DLD gap-size by changing the ratio of lateral-gap (GL) to downstream-gap (GD) enables efficient separation of RBCs without greatly restricting throughput. This method reduces the need for challenging fabrication of DLD pillars and provides new insight to the current DLD model. The separation shows an increase in DLD critical diameter resolution (separate smaller particles) and increase selectivity for non-spherical RBCs. The RBCs separate better as compared to standard DLD model with symmetrical gap sizes. This method can be applied to separate non-spherical bacteria or sub-micron particles to enhance throughput and DLD resolution.
NASA Astrophysics Data System (ADS)
Fu, Shihang; Zhang, Li; Hu, Yao; Ding, Xiang
2018-01-01
Confocal Raman Microscopy (CRM) has matured to become one of the most powerful instruments in analytical science because of its molecular sensitivity and high spatial resolution. Compared with conventional Raman Microscopy, CRM can perform three dimensions mapping of tiny samples and has the advantage of high spatial resolution thanking to the unique pinhole. With the wide application of the instrument, there is a growing requirement for the evaluation of the imaging performance of the system. Point-spread function (PSF) is an important approach to the evaluation of imaging capability of an optical instrument. Among a variety of measurement methods of PSF, the point source method has been widely used because it is easy to operate and the measurement results are approximate to the true PSF. In the point source method, the point source size has a significant impact on the final measurement accuracy. In this paper, the influence of the point source sizes on the measurement accuracy of PSF is analyzed and verified experimentally. A theoretical model of the lateral PSF for CRM is established and the effect of point source size on full-width at half maximum of lateral PSF is simulated. For long-term preservation and measurement convenience, PSF measurement phantom using polydimethylsiloxane resin, doped with different sizes of polystyrene microspheres is designed. The PSF of CRM with different sizes of microspheres are measured and the results are compared with the simulation results. The results provide a guide for measuring the PSF of the CRM.
Structure of n-alkyltrichlorosilane mono layers on Si(100)/SiO 2
H. -G. Steinruck; Ocko, B.; Will, J.; ...
2015-10-05
The structure of n-alkyltrichlorosilane self-assembled monolayers (SAMs) of alkyl chain lengths n = 12, 14, 18, and 22 formed on the amorphous native oxide of silicon (100) has been investigated via angstrom-resolution surface X-ray scattering techniques, with particular focus on the proliferation of lateral order along the molecules’ long axis. Grazing incidence diffraction shows that the monolayer is composed of hexagonally packed crystalline-like domains for n = 14, 18, and 22 with a lateral size of about 60 Å. However, Bragg rod analysis shows that ~12 of the CH 2 units are not included in the crystalline-like domains. We assignmore » this, and the limited lateral crystallites’ size, to strain induced by the size mismatch between the optimal chain–chain and headgroup–headgroup spacings. Lastly, analysis of X-ray reflectivity profiles for n = 12, 14, and 22 shows that the density profile used to successfully model n = 18 provides an excellent fit where the analysis-derived parameters provide complementary structural information to the grazing incidence results.« less
Boonna, Sureeporn; Tongta, Sunanta
2018-07-01
Structural transformation of crystallized debranched cassava starch prepared by temperature cycling (TC) treatment and then subjected to annealing (ANN), heat-moisture treatment (HMT) and dual hydrothermal treatments of ANN and HMT was investigated. The relative crystallinity, lateral crystal size, melting temperature and resistant starch (RS) content increased for all hydrothermally treated samples, but the slowly digestible starch (SDS) content decreased. The RS content followed the order: HMT → ANN > HMT > ANN → HMT > ANN > TC, respectively. The HMT → ANN sample showed a larger lateral crystal size with more homogeneity, whereas the ANN → HMT sample had a smaller lateral crystal size with a higher melting temperature. After cooking at 50% moisture, the increased RS content of samples was observed, particularly for the ANN → HMT sample. These results suggest that structural changes of crystallized debranched starch during hydrothermal treatments depend on initial crystalline characteristics and treatment sequences, influencing thermal stability, enzyme digestibility, and cooking stability. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ensemble coding remains accurate under object and spatial visual working memory load.
Epstein, Michael L; Emmanouil, Tatiana A
2017-10-01
A number of studies have provided evidence that the visual system statistically summarizes large amounts of information that would exceed the limitations of attention and working memory (ensemble coding). However the necessity of working memory resources for ensemble coding has not yet been tested directly. In the current study, we used a dual task design to test the effect of object and spatial visual working memory load on size averaging accuracy. In Experiment 1, we tested participants' accuracy in comparing the mean size of two sets under various levels of object visual working memory load. Although the accuracy of average size judgments depended on the difference in mean size between the two sets, we found no effect of working memory load. In Experiment 2, we tested the same average size judgment while participants were under spatial visual working memory load, again finding no effect of load on averaging accuracy. Overall our results reveal that ensemble coding can proceed unimpeded and highly accurately under both object and spatial visual working memory load, providing further evidence that ensemble coding reflects a basic perceptual process distinct from that of individual object processing.
NASA Astrophysics Data System (ADS)
Sund, Nicole; Porta, Giovanni; Bolster, Diogo; Parashar, Rishi
2017-11-01
Prediction of effective transport for mixing-driven reactive systems at larger scales, requires accurate representation of mixing at small scales, which poses a significant upscaling challenge. Depending on the problem at hand, there can be benefits to using a Lagrangian framework, while in others an Eulerian might have advantages. Here we propose and test a novel hybrid model which attempts to leverage benefits of each. Specifically, our framework provides a Lagrangian closure required for a volume-averaging procedure of the advection diffusion reaction equation. This hybrid model is a LAgrangian Transport Eulerian Reaction Spatial Markov model (LATERS Markov model), which extends previous implementations of the Lagrangian Spatial Markov model and maps concentrations to an Eulerian grid to quantify closure terms required to calculate the volume-averaged reaction terms. The advantage of this approach is that the Spatial Markov model is known to provide accurate predictions of transport, particularly at preasymptotic early times, when assumptions required by traditional volume-averaging closures are least likely to hold; likewise, the Eulerian reaction method is efficient, because it does not require calculation of distances between particles. This manuscript introduces the LATERS Markov model and demonstrates by example its ability to accurately predict bimolecular reactive transport in a simple benchmark 2-D porous medium.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, D; Usmani, N; Sloboda, R
Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogatemore » urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset of peripheral seeds involved, but lateral shearing movement can have greater consequences for local dose coverage.« less
NASA Technical Reports Server (NTRS)
Lichtenstein, J. H.
1978-01-01
An analytical method of computing the averaging effect of wing-span size on the loading of a wing induced by random turbulence was adapted for use on a digital electronic computer. The turbulence input was assumed to have a Dryden power spectral density. The computations were made for lift, rolling moment, and bending moment for two span load distributions, rectangular and elliptic. Data are presented to show the wing-span averaging effect for wing-span ratios encompassing current airplane sizes. The rectangular wing-span loading showed a slightly greater averaging effect than did the elliptic loading. In the frequency range most bothersome to airplane passengers, the wing-span averaging effect can reduce the normal lift load, and thus the acceleration, by about 7 percent for a typical medium-sized transport. Some calculations were made to evaluate the effect of using a Von Karman turbulence representation. These results showed that using the Von Karman representation generally resulted in a span averaging effect about 3 percent larger.
NASA Astrophysics Data System (ADS)
Tessonnier, T.; Mairani, A.; Brons, S.; Sala, P.; Cerutti, F.; Ferrari, A.; Haberer, T.; Debus, J.; Parodi, K.
2017-08-01
In the field of particle therapy helium ion beams could offer an alternative for radiotherapy treatments, owing to their interesting physical and biological properties intermediate between protons and carbon ions. We present in this work the comparisons and validations of the Monte Carlo FLUKA code against in-depth dosimetric measurements acquired at the Heidelberg Ion Beam Therapy Center (HIT). Depth dose distributions in water with and without ripple filter, lateral profiles at different depths in water and a spread-out Bragg peak were investigated. After experimentally-driven tuning of the less known initial beam characteristics in vacuum (beam lateral size and momentum spread) and simulation parameters (water ionization potential), comparisons of depth dose distributions were performed between simulations and measurements, which showed overall good agreement with range differences below 0.1 mm and dose-weighted average dose-differences below 2.3% throughout the entire energy range. Comparisons of lateral dose profiles showed differences in full-width-half-maximum lower than 0.7 mm. Measurements of the spread-out Bragg peak indicated differences with simulations below 1% in the high dose regions and 3% in all other regions, with a range difference less than 0.5 mm. Despite the promising results, some discrepancies between simulations and measurements were observed, particularly at high energies. These differences were attributed to an underestimation of dose contributions from secondary particles at large angles, as seen in a triple Gaussian parametrization of the lateral profiles along the depth. However, the results allowed us to validate FLUKA simulations against measurements, confirming its suitability for 4He ion beam modeling in preparation of clinical establishment at HIT. Future activities building on this work will include treatment plan comparisons using validated biological models between proton and helium ions, either within a Monte Carlo treatment planning engine based on the same FLUKA code, or an independent analytical planning system fed with a validated database of inputs calculated with FLUKA.
Tessonnier, T; Mairani, A; Brons, S; Sala, P; Cerutti, F; Ferrari, A; Haberer, T; Debus, J; Parodi, K
2017-08-01
In the field of particle therapy helium ion beams could offer an alternative for radiotherapy treatments, owing to their interesting physical and biological properties intermediate between protons and carbon ions. We present in this work the comparisons and validations of the Monte Carlo FLUKA code against in-depth dosimetric measurements acquired at the Heidelberg Ion Beam Therapy Center (HIT). Depth dose distributions in water with and without ripple filter, lateral profiles at different depths in water and a spread-out Bragg peak were investigated. After experimentally-driven tuning of the less known initial beam characteristics in vacuum (beam lateral size and momentum spread) and simulation parameters (water ionization potential), comparisons of depth dose distributions were performed between simulations and measurements, which showed overall good agreement with range differences below 0.1 mm and dose-weighted average dose-differences below 2.3% throughout the entire energy range. Comparisons of lateral dose profiles showed differences in full-width-half-maximum lower than 0.7 mm. Measurements of the spread-out Bragg peak indicated differences with simulations below 1% in the high dose regions and 3% in all other regions, with a range difference less than 0.5 mm. Despite the promising results, some discrepancies between simulations and measurements were observed, particularly at high energies. These differences were attributed to an underestimation of dose contributions from secondary particles at large angles, as seen in a triple Gaussian parametrization of the lateral profiles along the depth. However, the results allowed us to validate FLUKA simulations against measurements, confirming its suitability for 4 He ion beam modeling in preparation of clinical establishment at HIT. Future activities building on this work will include treatment plan comparisons using validated biological models between proton and helium ions, either within a Monte Carlo treatment planning engine based on the same FLUKA code, or an independent analytical planning system fed with a validated database of inputs calculated with FLUKA.
48 CFR 52.212-1 - Instructions to Offerors-Commercial Items.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Classification System (NAICS) code and small business size standard. The NAICS code and small business size... Government infrastructure not later than 5:00 p.m. one working day prior to the date specified for receipt of...
NASA Astrophysics Data System (ADS)
Takahashi, Toshimichi
2018-05-01
The tyre model which formerly developed by the author et al. and describes the tyre transient responses of side force and aligning moment under the time-varying vertical force was implemented to the vehicle dynamics simulation software and the influence of tyre side force transient property on the vehicle behaviour was investigated. The vehicle responses with/without tyre transient property on sinusoidally undulated road surfaces were simulated and compared. It was found that the average lateral acceleration of the vehicle at the sinusoidal steering wheel angle input decreases on the undulated road of long wavelength (3 m) for both cases, but when the wavelength becomes shorter (1 m), the average lateral acceleration increases only in the case that the transient property is considered. The cause of those changes is explained by using the tyre-related variables. Also the steady-state turning behaviour of the vehicle on undulated roads are shown and discussed.
Surface slip during large Owens Valley earthquakes
Haddon, E.K.; Amos, C.B.; Zielke, O.; Jayko, Angela S.; Burgmann, R.
2016-01-01
The 1872 Owens Valley earthquake is the third largest known historical earthquake in California. Relatively sparse field data and a complex rupture trace, however, inhibited attempts to fully resolve the slip distribution and reconcile the total moment release. We present a new, comprehensive record of surface slip based on lidar and field investigation, documenting 162 new measurements of laterally and vertically displaced landforms for 1872 and prehistoric Owens Valley earthquakes. Our lidar analysis uses a newly developed analytical tool to measure fault slip based on cross-correlation of sublinear topographic features and to produce a uniquely shaped probability density function (PDF) for each measurement. Stacking PDFs along strike to form cumulative offset probability distribution plots (COPDs) highlights common values corresponding to single and multiple-event displacements. Lateral offsets for 1872 vary systematically from ∼1.0 to 6.0 m and average 3.3 ± 1.1 m (2σ). Vertical offsets are predominantly east-down between ∼0.1 and 2.4 m, with a mean of 0.8 ± 0.5 m. The average lateral-to-vertical ratio compiled at specific sites is ∼6:1. Summing displacements across subparallel, overlapping rupture traces implies a maximum of 7–11 m and net average of 4.4 ± 1.5 m, corresponding to a geologic Mw ∼7.5 for the 1872 event. We attribute progressively higher-offset lateral COPD peaks at 7.1 ± 2.0 m, 12.8 ± 1.5 m, and 16.6 ± 1.4 m to three earlier large surface ruptures. Evaluating cumulative displacements in context with previously dated landforms in Owens Valley suggests relatively modest rates of fault slip, averaging between ∼0.6 and 1.6 mm/yr (1σ) over the late Quaternary.
Reliability in the Location of Hindlimb Motor Representations in Fischer-344 Rats
Frost, Shawn B.; Iliakova, Maria; Dunham, Caleb; Barbay, Scott; Arnold, Paul; Nudo, Randolph J.
2014-01-01
Object The purpose of the present study was to determine the feasibility of using a common laboratory rat strain for locating cortical motor representations of the hindlimb reliably. Methods Intracortical Microstimulation (ICMS) techniques were used to derive detailed maps of the hindlimb motor representations in six adult Fischer-344 rats. Results The organization of the hindlimb movement representation, while variable across individuals in topographic detail, displayed several commonalities. The hindlimb representation was positioned posterior to the forelimb motor representation and postero-lateral to the motor trunk representation. The areal extent of the hindlimb representation across the cortical surface averaged 2.00 +/− 0.50 mm2. Superimposing individual maps revealed an overlapping area measuring 0.35 mm2, indicating that the location of the hindlimb representation can be predicted reliably based on stereotactic coordinates. Across the sample of rats, the hindlimb representation was found 1.25–3.75 mm posterior to Bregma, with an average center location ~ 2.6 mm posterior to Bregma. Likewise, the hindlimb representation was found 1–3.25 mm lateral to the midline, with an average center location ~ 2 mm lateral to midline. Conclusions The location of the cortical hindlimb motor representation in Fischer-344 rats can be reliably located based on its stereotactic position posterior to Bregma and lateral to the longitudinal skull suture at midline. The ability to accurately predict the cortical localization of functional hindlimb territories in a rodent model is important, as such animal models are being used increasingly in the development of brain-computer interfaces for restoration of function after spinal cord injury. PMID:23725395
Housman, D.C.; Powers, H.H.; Collins, A.D.; Belnap, J.
2006-01-01
Biological soil crusts (cyanobacteria, mosses and lichens collectively) perform essential ecosystem services, including carbon (C) and nitrogen (N) fixation. Climate and land-use change are converting later successional soil crusts to early successional soil crusts with lower C and N fixation rates. To quantify the effect of such conversions on C and N dynamics in desert ecosystems we seasonally measured diurnal fixation rates in different biological soil crusts. We classified plots on the Colorado Plateau (Canyonlands) and Chihuahuan Desert (Jornada) as early (Microcoleus) or later successional (Nostoc/Scytonema or Placidium/Collema) and measured photosynthesis (Pn), nitrogenase activity (NA), and chlorophyll fluorescence (Fv/Fm) on metabolically active (moist) soil crusts. Later successional crusts typically had greater Pn, averaging 1.2-1.3-fold higher daily C fixation in Canyonlands and 2.4-2.8-fold higher in the Jornada. Later successional crusts also had greater NA, averaging 1.3-7.5-fold higher daily N fixation in Canyonlands and 1.3-25.0-fold higher in the Jornada. Mean daily Fv/Fm was also greater in later successional Canyonlands crusts during winter, and Jornada crusts during all seasons except summer. Together these findings indicate conversion of soil crusts back to early successional stages results in large reductions of C and N inputs into these ecosystems.
Formulation design space for stable, pH sensitive crystalline nifedipine nanoparticles.
Jog, Rajan; Unachukwu, Kenechi; Burgess, Diane J
2016-11-30
Enteric coated formulations protect drugs from degrading in the harsh environment of the stomach (acidic pH and enzymes), and promotes drug delivery to and absorption into the duodenum and/or later parts of the intestine. Four DoE models were applied to optimize formulation parameters for the preparation of pH sensitive nifedipine nanoparticles. Stability studies were performed on the optimized formulations to monitor any possible variation in particle size distribution, homogeneity index, surface charge and drug release (pH 1.2 and pH 6.8). Stability studies were performed for 3 months at 4°C, 25°C and 40°C. A combination of Eudragit ® L 100-55 and polyvinyl alcohol was determined to be the most effective in stabilizing the nanoparticle suspension. The average particle size distribution, polydispersity index and surface charge of the optimized pH sensitive nifedipine nanoparticles were determined to be 131.86±8.21nm, 0.135±0.008 and -7.631±0.146mV, respectively. Following three months storage, it was observed that the formulations stored at 4°C were stable in terms of particle size distribution, polydispersity index, surface charge, drug loading and drug release, whereas those stored at 25°C and 40°C were relatively unstable. A predictive model to prepare stable pH sensitive nifedipine nanoparticles, was successfully developed using multiple linear regression analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Two-stage controlled release system possesses excellent initial and long-term efficacy.
Luo, Jian; Jing, Tong-Fang; Zhang, Da-Xia; Zhang, Xian-Peng; Li, Beixing; Liu, Feng
2018-05-24
In this work, a series of polyurea-based lambda-cyhalothrin-loaded microcapsules (MCs) with three different size distributions (average diameters of 1.35 μm, MC-S; 5.13 μm, MC-M; and 21.48 μm, MC-L) were prepared and characterized. The results indicated that MCs with a smaller particle size distribution had a faster release rate and excellent initial efficacy against pests. MC-L had a remarkably slow incipient release rate, outstanding photostability and better later-stage efficacy than that of the other tested MCs. The results clarified that the diameter distribution of MCs is the key factor in determining the release property and bioactivity of the MC formulations. Subsequently, the binary mixture MC formulations of MC(+M), MC(S+L) and MC(M+L) were obtained by mixing MC-S, MC-M or MC-L at 1:1 to establish a two-stage release system utilized for foliar application situations. Greenhouse and field experiments showed that MC(S+L) provided an optimal efficacy, and its effective duration was much longer than that of the emulsifiable concentrate (EC) group. Therefore, the release system established in this study was simple and workable for regulating the initial and long-term efficacy by adjusting the particle size distribution; in addition, this system has potential applications in other fields such as drug delivery devices. Copyright © 2018 Elsevier B.V. All rights reserved.
Vertical and lateral forces applied to the bar during the bench press in novice lifters.
Duffey, Michael J; Challis, John H
2011-09-01
The purpose of this study was to determine the vertical and lateral forces applied to the bar during a maximal and a submaximal effort bench press lifts. For this study, 10 male and 8 female recreational lifters were recruited (mean height: 1.71 ± 0.08 m; mass: 73.7 ± 13.6 kg) and were asked to perform a maximal and submaximal (80% of maximal lift) bench press. These lifts were performed with a bar instrumented to record forces applied to it, via the hands, in the vertical direction and along the long axis of the bar. To determine the position of the bar and timing of events, 3D kinematic data were recorded and analyzed for both lifts. The subjects in this study averaged a maximal lift of 63 ± 29 kg (90 ± 31% bodyweight). The peak vertical force was 115 ± 22% (percentage of load), whereas for the submaximal condition it was 113 ± 20%; these forces were statistically different between conditions; they were not when expressed as a percentage of the load (p > 0.05). During all the lifts, the lateral forces were always outward along the bar. The lateral force profile was similar to that of the vertical force, albeit at a lesser magnitude. During the lift phase, the peak lateral force was on average 26.3 ± 3.9% of the vertical force for the maximal lift and 23.7 ± 3.9% of the vertical force for the submaximal lift. Given that the amount of force applied laterally to the bar was a similar percentage of vertical force irrespective of load, it appears that the generation of lateral forces during the bench press is a result of having the muscles engaged in generating vertical force.
Size Matters: Early Vocabulary as a Predictor of Language and Literacy Competence
ERIC Educational Resources Information Center
Lee, Joanne
2011-01-01
This paper investigated the predictive ability of expressive vocabulary size and lexical composition at age 2 on later language and literacy skills from ages 3 through 11. Multivariate analysis of covariance was performed to compare 16 language and literacy outcomes between children with large expressive vocabulary size at 24 months (N = 1,073)…
A spectral clustering search algorithm for predicting shallow landslide size and location
Dino Bellugi; David G. Milledge; William E. Dietrich; Jim A. McKean; J. Taylor Perron; Erik B. Sudderth; Brian Kazian
2015-01-01
The potential hazard and geomorphic significance of shallow landslides depend on their location and size. Commonly applied one-dimensional stability models do not include lateral resistances and cannot predict landslide size. Multi-dimensional models must be applied to specific geometries, which are not known a priori, and testing all possible geometries is...
Min, Yi; Song, Ying; Gao, Yuan; Dummer, Paul M H
2016-08-01
This study aimed to present a new method based on numeric calculus to provide data on the theoretical volume ratio of voids when using the cold lateral compaction technique in canals with various diameters and tapers. Twenty-one simulated mathematical root canal models were created with different tapers and sizes of apical diameter, and were filled with defined sizes of standardized accessory gutta-percha cones. The areas of each master and accessory gutta-percha cone as well as the depth of their insertion into the canals were determined mathematically in Microsoft Excel. When the first accessory gutta-percha cone had been positioned, the residual area of void was measured. The areas of the residual voids were then measured repeatedly upon insertion of additional accessary cones until no more could be inserted in the canal. The volume ratio of voids was calculated through measurement of the volume of the root canal and mass of gutta-percha cones. The theoretical volume ratio of voids was influenced by the taper of canal, the size of apical preparation and the size of accessory gutta-percha cones. Greater apical preparation size and larger taper together with the use of smaller accessory cones reduced the volume ratio of voids in the apical third. The mathematical model provided a precise method to determine the theoretical volume ratio of voids in root-filled canals when using cold lateral compaction.
Rayner, Wendy Jane; Barber, Sophy K; Spencer, Richard James
2015-03-01
To determine the effect of canine tooth characteristics and symmetry on perceived smile attractiveness when maxillary canine teeth are substituted for missing lateral incisors. Prospective, cross-sectional study. Non-clinical study undertaken from Leeds Dental Institute, UK. A composite full-face image of a smiling female was used to display various dentitions; a control image with an 'ideal' smile, plus six further images substituting the maxillary lateral incisors with canine teeth either unilaterally or bilaterally with varying size, shape, colour and gingival margin level. The seven images were shown to orthodontists (n = 30), dentists (n = 30) and lay people (n = 30) who were asked to rate smile attractiveness using a visual analogue scale. Dental professionals rated smiles with canine substitution for lateral incisor agenesis to be significantly less attractive than an ideal smile unless the substituted canine teeth approximated the lateral incisor in terms of size, shape, colour and gingival margin. Lay people did not find smiles where canine teeth were substituted for lateral incisors significantly more or less attractive than an ideal smile regardless of the canine tooth characteristics. Dental professionals were significantly more perceptive than lay people to the deviation from ideal smile aesthetics due to canine substitution. Smiles with unilateral canine substitution were not found to be significantly less attractive than bilateral canine substitution by all groups. Canine characteristics and observer status will affect how canine substitution for lateral incisor agenesis is viewed in terms of aesthetic outcome.
ERIC Educational Resources Information Center
O'Neill, Audrey Myerson
2011-01-01
Background: This longitudinal study of 20 average and bright adults with parents with cognitive difficulties follows a study 20 years earlier of their childhood adaptation to their parents. Method: Semistructured interviews about life situation and changes and perception of family-of-origin. Results: The participants' socioeconomic status changed…
40 CFR 86.1865-12 - How to comply with the fleet average CO2 standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of § 86.1801-12(j), CO2 fleet average exhaust emission standards apply to: (i) 2012 and later model... businesses meeting certain criteria may be exempted from the greenhouse gas emission standards in § 86.1818... standards applicable in a given model year are calculated separately for passenger automobiles and light...
Wang, Zhuochen; Martin, K. Heath; Huang, Wenbin; Dayton, Paul A.; Jiang, Xiaoning
2016-01-01
Techniques to image the microvasculature may play an important role in imaging tumor-related angiogenesis and vasa vasorum associated with vulnerable atherosclerotic plaques. However, the microvasculature associated with these pathologies is difficult to detect using traditional B-mode ultrasound or even harmonic imaging due to small vessel size and poor differentiation from surrounding tissue. Acoustic angiography, a microvascular imaging technique which utilizes superharmonic imaging (detection of higher order harmonics of microbubble response), can yield a much higher contrast to tissue ratio (CTR) than second harmonic imaging methods. In this work, two dual-frequency transducers using lateral mode transmitters were developed for superharmonic detection and acoustic angiography imaging in intracavity applications. A single element dual-frequency IVUS transducer was developed for concept validation, which achieved larger signal amplitude, better contrast to noise ratio (CNR) and pulse length compared to the previous work. A dual-frequency PMN-PT array transducer was then developed for superharmonic imaging with dynamic focusing. The axial and lateral size of the microbubbles in a 200 μm tube were measured to be 269 μm and 200 μm, respectively. The maximum CNR was calculated to be 22 dB. These results show that superharmonic imaging with a low frequency lateral mode transmitter is a feasible alternative to thickness mode transmitters when final transducer size requirements dictate design choices. PMID:27775903
Processing vertical size disparities in distinct depth planes.
Duke, Philip A; Howard, Ian P
2012-08-17
A textured surface appears slanted about a vertical axis when the image in one eye is horizontally enlarged relative to the image in the other eye. The surface appears slanted in the opposite direction when the same image is vertically enlarged. Two superimposed textured surfaces with different horizontal size disparities appear as two surfaces that differ in slant. Superimposed textured surfaces with equal and opposite vertical size disparities appear as a single frontal surface. The vertical disparities are averaged. We investigated whether vertical size disparities are averaged across two superimposed textured surfaces in different depth planes or whether they induce distinct slants in the two depth planes. In Experiment 1, two superimposed textured surfaces with different vertical size disparities were presented in two depth planes defined by horizontal disparity. The surfaces induced distinct slants when the horizontal disparity was more than ±5 arcmin. Thus, vertical size disparities are not averaged over surfaces with different horizontal disparities. In Experiment 2 we confirmed that vertical size disparities are processed in surfaces away from the horopter, so the results of Experiment 1 cannot be explained by the processing of vertical size disparities in a fixated surface only. Together, these results show that vertical size disparities are processed separately in distinct depth planes. The results also suggest that vertical size disparities are not used to register slant globally by their effect on the registration of binocular direction of gaze.
Chen, Ting; Zhang, Miao; Jabbour, Salma; Wang, Hesheng; Barbee, David; Das, Indra J; Yue, Ning
2018-04-10
Through-plane motion introduces uncertainty in three-dimensional (3D) motion monitoring when using single-slice on-board imaging (OBI) modalities such as cine MRI. We propose a principal component analysis (PCA)-based framework to determine the optimal imaging plane to minimize the through-plane motion for single-slice imaging-based motion monitoring. Four-dimensional computed tomography (4DCT) images of eight thoracic cancer patients were retrospectively analyzed. The target volumes were manually delineated at different respiratory phases of 4DCT. We performed automated image registration to establish the 4D respiratory target motion trajectories for all patients. PCA was conducted using the motion information to define the three principal components of the respiratory motion trajectories. Two imaging planes were determined perpendicular to the second and third principal component, respectively, to avoid imaging with the primary principal component of the through-plane motion. Single-slice images were reconstructed from 4DCT in the PCA-derived orthogonal imaging planes and were compared against the traditional AP/Lateral image pairs on through-plane motion, residual error in motion monitoring, absolute motion amplitude error and the similarity between target segmentations at different phases. We evaluated the significance of the proposed motion monitoring improvement using paired t test analysis. The PCA-determined imaging planes had overall less through-plane motion compared against the AP/Lateral image pairs. For all patients, the average through-plane motion was 3.6 mm (range: 1.6-5.6 mm) for the AP view and 1.7 mm (range: 0.6-2.7 mm) for the Lateral view. With PCA optimization, the average through-plane motion was 2.5 mm (range: 1.3-3.9 mm) and 0.6 mm (range: 0.2-1.5 mm) for the two imaging planes, respectively. The absolute residual error of the reconstructed max-exhale-to-inhale motion averaged 0.7 mm (range: 0.4-1.3 mm, 95% CI: 0.4-1.1 mm) using optimized imaging planes, averaged 0.5 mm (range: 0.3-1.0 mm, 95% CI: 0.2-0.8 mm) using an imaging plane perpendicular to the minimal motion component only and averaged 1.3 mm (range: 0.4-2.8 mm, 95% CI: 0.4-2.3 mm) in AP/Lateral orthogonal image pairs. The root-mean-square error of reconstructed displacement was 0.8 mm for optimized imaging planes, 0.6 mm for imaging plane perpendicular to the minimal motion component only, and 1.6 mm for AP/Lateral orthogonal image pairs. When using the optimized imaging planes for motion monitoring, there was no significant absolute amplitude error of the reconstructed motion (P = 0.0988), while AP/Lateral images had significant error (P = 0.0097) with a paired t test. The average surface distance (ASD) between overlaid two-dimensional (2D) tumor segmentation at end-of-inhale and end-of-exhale for all eight patients was 0.6 ± 0.2 mm in optimized imaging planes and 1.4 ± 0.8 mm in AP/Lateral images. The Dice similarity coefficient (DSC) between overlaid 2D tumor segmentation at end-of-inhale and end-of-exhale for all eight patients was 0.96 ± 0.03 in optimized imaging planes and 0.89 ± 0.05 in AP/Lateral images. Both ASD (P = 0.034) and DSC (P = 0.022) were significantly improved in the optimized imaging planes. Motion monitoring using imaging planes determined by the proposed PCA-based framework had significantly improved performance. Single-slice image-based motion tracking can be used for clinical implementations such as MR image-guided radiation therapy (MR-IGRT). © 2018 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Hernández-Pinero, Jorge Luis; Terrón-Rebolledo, Manuel; Foroughbakhch, Rahim; Moreno-Limón, Sergio; Melendrez, M. F.; Solís-Pomar, Francisco; Pérez-Tijerina, Eduardo
2016-11-01
Mixing aqueous silver solutions with aqueous leaf aromatic plant extracts from basil, mint, marjoram and peppermint resulted in the synthesis of quasi-spherical silver nanoparticles in a range of size between 2 and 80 nm in diameter as analyzed by analytical high-resolution electron microscopy. The average size could be controlled by applying heat to the initial reaction system at different rates of heating, and by the specific botanical species employed for the reaction. Increasing the rate of heating resulted in a statistically significant decrease in the size of the nanoparticles produced, regardless of the species employed. This fact was more evident in the case of marjoram, which decreased the average diameter from 27 nm at a slow rate of heating to 8 nm at a high rate of heating. With regard to the species, minimum sizes of <10 nm were obtained with basil and peppermint, while marjoram and mint yielded an average size between 10 and 25 nm. The results indicate that aromatic plant extracts can be used to achieve the controlled synthesis of metal nanoparticles.
Influences of Co doping on the structural and optical properties of ZnO nanostructured
NASA Astrophysics Data System (ADS)
Majeed Khan, M. A.; Wasi Khan, M.; Alhoshan, Mansour; Alsalhi, M. S.; Aldwayyan, A. S.
2010-07-01
Pure and Co-doped ZnO nanostructured samples have been synthesized by a chemical route. We have studied the structural and optical properties of the samples by using X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), field-emission transmission electron microscope (FETEM), energy-dispersive X-ray (EDX) analysis and UV-VIS spectroscopy. The XRD patterns show that all the samples are hexagonal wurtzite structures. Changes in crystallite size due to mechanical activation were also determined from X-ray measurements. These results were correlated with changes in particle size followed by SEM and TEM. The average crystallite sizes obtained from XRD were between 20 to 25 nm. The TEM images showed the average particle size of undoped ZnO nanostructure was about 20 nm whereas the smallest average grain size at 3% Co was about 15 nm. Optical parameters such as absorption coefficient ( α), energy band gap ( E g ), the refractive index ( n), and dielectric constants ( σ) have been determined using different methods.
In vitro wear assessment of the Charité Artificial Disc according to ASTM recommendations.
Serhan, Hassan A; Dooris, Andrew P; Parsons, Matthew L; Ares, Paul J; Gabriel, Stefan M
2006-08-01
Biomechanical laboratory research. To evaluate the potential for Ultra High Molecular Weight Polyethylene (UHMWPE) wear debris from the Charité Artificial Disc. Cases of osteolysis from artificial discs are extremely rare, but hip and knee studies demonstrate the osteolytic potential and clinical concern of UHMWPE wear debris. Standards for testing artificial discs continue to evolve, and there are few detailed reports of artificial disc wear characterizations. Implant assemblies were tested to 10 million cycles of +/- 7.5 degrees flexion-extension or +/- 7.5 degrees left/right lateral bending, both with +/- 2 degrees axial rotation and 900 N to 1,850 N cyclic compression. Cores were weighed, measured, and photographed. Soak and loaded soak controls were used. Wear debris was analyzed via scanning electron microscopy and particle counters. The average total wear of the implants was 0.11 and 0.13 mg per million cycles, before and after accounting for serum absorption, respectively. Total height loss was approximately 0.2 mm. Wear debris ranged from submicron to > 10 microm in size. Under these test conditions, the Charité Artificial Disc produced minimal wear debris. Debris size and morphology tended to be similar to other CoCr-UHMWPE joints. More testing is necessary to evaluate the implants under a spectrum of loading conditions.
When will the Antarctic Ozone Hole Recover?
NASA Technical Reports Server (NTRS)
Newman, Paul A.; Nash, Eric R.; Kawa, S. Randolph; Montzka, Steve
2006-01-01
The Antarctic ozone hole develops each year and culminates by early Spring. Antarctic ozone values have been monitored since 1979 using satellite observations from the .TOMS instrument. The severity of the hole has been assessed from TOMS using the minimum total ozone value from the October monthly mean (depth of the hole) and by calculating the average size during the September-October period. Ozone is mainly destroyed by halogen catalytic cycles, and these losses are modulated by temperature variations in the collar of the polar lower stratospheric vortex. In this presentation, we show the relationships of halogens and temperature to, both the size and depth of the hole. Because atmospheric halogen levels are responding to international agreements that limit or phase out production, the amount of halogens in the stratosphere should decrease over the next few decades. Using projections of halogen levels combined with age-of-air estimates, we find that the ozone hole is recovering at an extremely slow rate and that large ozone holes will regularly recur over the next 2 decades. The ozone hole will begin to show first signs of recovery in about 2023, and the hole will fully recover to pre-1980 levels in approximately 2070. This 2070 recovery is 20 years later than recent projections.
Ziegelwanger, Harald; Majdak, Piotr; Kreuzer, Wolfgang
2015-01-01
Head-related transfer functions (HRTFs) can be numerically calculated by applying the boundary element method on the geometry of a listener’s head and pinnae. The calculation results are defined by geometrical, numerical, and acoustical parameters like the microphone used in acoustic measurements. The scope of this study was to estimate requirements on the size and position of the microphone model and on the discretization of the boundary geometry as triangular polygon mesh for accurate sound localization. The evaluation involved the analysis of localization errors predicted by a sagittal-plane localization model, the comparison of equivalent head radii estimated by a time-of-arrival model, and the analysis of actual localization errors obtained in a sound-localization experiment. While the average edge length (AEL) of the mesh had a negligible effect on localization performance in the lateral dimension, the localization performance in sagittal planes, however, degraded for larger AELs with the geometrical error as dominant factor. A microphone position at an arbitrary position at the entrance of the ear canal, a microphone size of 1 mm radius, and a mesh with 1 mm AEL yielded a localization performance similar to or better than observed with acoustically measured HRTFs. PMID:26233020
Examination of the Lateral Attenuation of Aircraft Noise
NASA Technical Reports Server (NTRS)
Plotkin, Kenneth J.; Hobbs, Christopher M.; Bradley, Kevin A.; Shepherd, Kevin P. (Technical Monitor)
2000-01-01
Measurements of the lateral attenuation of noise from aircraft operations at Denver International Airport were made at distances up to 2000 feet and elevation angles up to 27 degrees. Attenuation Calculated from modem ground impedance theory agrees well with average measured attenuation. The large variability between measured and predicted levels observed at small elevation angles is demonstrated to be due to refraction by wind and temperature gradients.
The Interplay between Women's Life Course Work Patterns and Financial Planning for Later Life
ERIC Educational Resources Information Center
Berger, Ellie D.; Denton, Margaret A.
2004-01-01
In order to gain a comprehensive understanding of the interplay between women's life course work patterns and their financial planning for later life, we examined data from semi-structured interviews with retired women (n = 28) aged 59 to 92. The majority of women disrupted their careers at some point in time, for an average of 14 years, primarily…
40 CFR 86.007-15 - NOX and particulate averaging, trading, and banking for heavy-duty engines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... discount factor of 0.8 (0.9 × 0.888 = 0.8). (5) For diesel engine families, the combined number of engines... heavy-duty diesel engine families for that model year. (6) The FEL must be expressed to the same number... 2007 and later model year diesel engine families, or generated for 2008 and later model year Otto-cycle...
Freeman, Jacob L; Sampath, Raghuram; Quattlebaum, Steven Craig; Casey, Michael A; Folzenlogen, Zach A; Ramakrishnan, Vijay R; Youssef, A Samy
2017-07-21
OBJECTIVE The endoscopic endonasal transmaxillary transpterygoid (TMTP) approach has been the gateway for lateral skull base exposure. Removal of the cartilaginous eustachian tube (ET) and lateral mobilization of the internal carotid artery (ICA) are technically demanding adjunctive steps that are used to access the petroclival region. The gained expansion of the deep working corridor provided by these maneuvers has yet to be quantified. METHODS The TMTP approach with cartilaginous ET removal and ICA mobilization was performed in 5 adult cadaveric heads (10 sides). Accessible portions of the petrous apex were drilled during the following 3 stages: 1) before ET removal, 2) after ET removal but before ICA mobilization, and 3) after ET removal and ICA repositioning. Resection volumes were calculated using 3D reconstructions generated from thin-slice CT scans obtained before and after each step of the dissection. RESULTS The average petrous temporal bone resection volumes at each stage were 0.21 cm 3 , 0.71 cm 3 , and 1.32 cm 3 (p < 0.05, paired t-test). Without ET removal, inferior and superior access to the petrous apex was limited. Furthermore, without ICA mobilization, drilling was confined to the inferior two-thirds of the petrous apex. After mobilization, the resection was extended superiorly through the upper extent of the petrous apex. CONCLUSIONS The transpterygoid corridor to the petroclival region is maximally expanded by the resection of the cartilaginous ET and mobilization of the paraclival ICA. These added maneuvers expanded the deep window almost 6 times and provided more lateral access to the petroclival region with a maximum volume of 1.5 cm 3 . This may result in the ability to resect small-to-moderate sized intradural petroclival lesions up to that volume. Larger lesions may better be approached through an open transcranial approach.
NASA Astrophysics Data System (ADS)
Barettin, Daniele; Auf der Maur, Matthias; De Angelis, Roberta; Prosposito, Paolo; Casalboni, Mauro; Pecchia, Alessandro
2015-03-01
We report on numerical simulations of InP surface lateral quantum-dot molecules on In0.48Ga0.52P buffer, using a model strictly derived by experimental results by extrapolation of the molecules shape from atomic force microscopy images. Our study has been inspired by the comparison of a photoluminescence spectrum of a high-density InP surface quantum dot sample with a numerical ensemble average given by a weighted sum of simulated single quantum-dot spectra. A lack of experimental optical response from the smaller dots of the sample is found to be due to strong inter-dot strain fields, which influence the optoelectronic properties of lateral quantum-dot molecules. Continuum electromechanical, k →.p → bandstructure, and optical calculations are presented for two different molecules, the first composed of two dots of nearly identical dimensions (homonuclear), the second of two dots with rather different sizes (heteronuclear). We show that in the homonuclear molecule the hydrostatic strain raises a potential barrier for the electrons in the connection zone between the dots, while conversely the holes do not experience any barrier, which considerably increases the coupling. Results for the heteronuclear molecule show instead that its dots do not appear as two separate and distinguishable structures, but as a single large dot, and no optical emission is observed in the range of higher energies where the smaller dot is supposed to emit. We believe that in samples of such a high density the smaller dots result as practically incorporated into bigger molecular structures, an effect strongly enforced by the inter-dot strain fields, and consequently it is not possible to experimentally obtain a separate optical emission from the smaller dots.
Wagner, Daniel; Kamer, Lukas; Sawaguchi, Takeshi; Richards, R Geoff; Noser, Hansrudi; Rommens, Pol M
2016-04-06
Fragility fractures of the sacrum are increasing in prevalence due to osteoporosis and epidemiological changes and are challenging in their treatment. They exhibit specific fracture patterns with unilateral or bilateral fractures lateral to the sacral foramina, and sometimes an additional transverse fracture leads to spinopelvic dissociation. The goal of this study was to assess sacral bone mass distribution and corresponding changes with decreased general bone mass. Clinical computed tomography (CT) scans of intact pelves in ninety-one individuals (mean age and standard deviation, 61.5 ± 11.3 years) were used to generate three-dimensional (3D) models of the sacrum averaging bone mass in Hounsfield units (HU). Individuals with decreased general bone mass were identified by measuring bone mass in L5 (group 1 with <100 HU; in contrast to group 2 with ≥100 HU). In group 1, a large zone of negative Hounsfield units was located in the paraforaminal lateral region from S1 to S3. Along the trans-sacral corridors, a Hounsfield unit peak was observed laterally, corresponding to cortical bone of the auricular surface. The lowest Hounsfield unit values were found in the paraforaminal lateral region in the sacral ala. An intermediate level of bone mass was observed in the area of the vertebral bodies, which also demonstrated the largest difference between groups 1 and 2. Overall, the Hounsfield units were lower at S2 than S1. The models of averaged bone mass in the sacrum revealed a distinct 3D distribution pattern. The negative values in the paraforaminal lateral region may explain the specific fracture patterns in fragility fractures of the sacrum involving the lateral areas of the sacrum. Transverse fractures located between S1 and S2 leading to spinopelvic dissociation may occur because of decreased bone mass in S2. The largest difference between the studied groups was found in the vertebral bodies and might support the use of transsacral or cement-augmented implants. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Changes in Cranial Base Morphology in Class I and Class II Division 1 Malocclusions
Agarwal, Anirudh; Pandey, Harsh; Bajaj, Kamal; Pandey, Lavesh
2013-01-01
Introduction: The cranial base plays a key role in craniofacial growth; it helps to integrate spatially and functionally different patterns of growth in various adjoining regions of the skull such as components of the brain, the nasal and oral cavity and the pharynx. The aim of this study was to evaluate the difference in cranial base flexure between skeletal and dental Class I and Class II division 1. Materials & Methods: Lateral cephalometric radiograph, of Class I and Class II with an average growth pattern were analyzed and compared. A total of 103 patients having class I (n=52) and class II (n=51) malocclusion, were taken from Department of Orthodontics, Rajasthan Dental College & Hospital, Jaipur. Cranial base angle (N-S-Ar) and ANB were measured on pre treatment lateral cephalograms. Results: In this study cranial base angle did not show statistically significant difference between the two groups studied. Conclusion: In the assessment of orthodontic problems involving anteroposterior malrelationships of the jaws, the problem is usually the result of size, form and position of the jaw. The present study failed to find any differences in cranial base angle between sagittal malocclusions. How to cite this article: Agarwal A, Pandey H, Bajaj K, Pandey L. Changes in Cranial Base Morphology in Class I and Class II Division 1 Malocclusion. J Int Oral Health 2013; 5(1):39-42. PMID:24155576
Denisow, Bożena; Masierowska, Marzena; Antoń, Sebastian
2016-11-01
The data relating to the nectaries and nectar secretion in invasive Brassicacean taxa are scarce. In the present paper, the nectar production and nectar carbohydrate composition as well as the morphology, anatomy and ultrastructure of the floral nectaries in Bunias orientalis were investigated. Nectary glands were examined using light, fluorescence, scanning electron and transmission electron microscopy. The quantities of nectar produced by flowers and total sugar mass in nectar were relatively low. Total nectar carbohydrate production per 10 flowers averaged 0.3 mg. Nectar contained exclusively glucose (G) and fructose (F) with overall G/F ratio greater than 1. The flowers of B. orientalis have four nectaries placed at the base of the ovary. The nectarium is intermediate between two nectary types: the lateral and median nectary type (lateral and median glands stay separated) and the annular nectary type (both nectaries are united into one). Both pairs of glands represent photosynthetic type and consist of epidermis and glandular tissue. However, they differ in their shape, size, secretory activity, dimensions of epidermal and parenchyma cells, thickness of secretory parenchyma, phloem supply, presence of modified stomata and cuticle ornamentation. The cells of nectaries contain dense cytoplasm, plastids with starch grains and numerous mitochondria. Companion cells of phloem lack cell wall ingrowths. The ultrastructure of secretory cells indicates an eccrine mechanism of secretion. Nectar is exuded throughout modified stomata.
Norman, Stephanie A; Goertz, Caroline E C; Burek, Kathy A; Quakenbush, Lori T; Cornick, Leslie A; Romano, Tracy A; Spoon, Tracey; Miller, Woutrina; Beckett, Laurel A; Hobbs, Roderick C
2012-01-01
We collected blood from 18 beluga whales (Delphinapterus leucas), live-captured in Bristol Bay, Alaska, USA, in May and September 2008, to establish baseline hematologic and serum chemistry values and to determine whether there were significant differences in hematologic values by sex, season, size/age, or time during the capture period. Whole blood was collected within an average of 19 min (range=11-30 min) after the net was set for capture, and for eight animals, blood collection was repeated in a later season after between 80-100 min; all blood was processed within 12 hr. Mean hematocrit, chloride, creatinine, total protein, albumin, and alkaline phosphatase were significantly lower in May than they were in September, whereas mean corpuscular hemoglobin concentration, monocytes, phosphorous, magnesium, blood urea nitrogen, alanine aminotransferase, aspartate aminotransferase, γ-glutamyltranspeptidase, and creatinine kinase were significantly higher. Mean total protein, white blood cell count, neutrophils, and lymphocytes were significantly higher early in the capture period than they were later. No significant differences in blood analyte values were noted between males and females. Using overall body length as a proxy for age, larger (older) belugas had lower white blood cell, lymphocyte, and eosinophil counts as well as lower sodium, potassium, and calcium levels but higher creatinine levels than smaller belugas. These data provide values for hematology and serum chemistry for comparisons with other wild belugas.
Age and growth of the kiyi, Leucichthys kiyi Koelz, in Lake Michigan
Deason, Hilary J.; Hile, Ralph
1947-01-01
Ages were determined and individual growth histories were calculated from the examination and measurement of the scales of 1,649 kiyis captured at seven localities in Lake Michigan in 1931 and 1932. The numbers of individuals employed for the investigation of other phases of the life history (such as length-frequency distributions, length-weight relationship, and sex ratio) varied according to the amount of data available or required. Age-group IV was dominant in the 1931 collections from Racine, Port Washington, and Kewaunee, Wisconsin, and age-group V dominated the 1932 samples from the Fox Islands and from three localities southward of Manistique, Michigan. A trend was noticeable toward an increase in average age from south to north. Among the explanations suggested for the observed differences in age composition were: Variation with latitude in the natural span of life; differences in fishing intensity; fluctuations in the strength of year classes (to account possibly for the shift in the dominant age group from 1931 to 1932). The oldest male kiyi belonged to the VII group and the oldest female was a member of the X group. The possible distorting effects of such factors as gear selection traceable to differences in the mesh sizes of nets fished in 1931 and 1932, selection by nets on the basis of the condition (K) of the fish, and local variations in fishing intensity and hence in the selective destruction of rapidly growing individuals in the fishery were held to be sufficiently great to render doubtful the significance of most of the observed local differences in growth rate. Kiyis from all samples were combined to determine the general growth in length. The growth in weight of the Fox Islands fish, however, was considered separately as these fish were consistently lighter than kiyis of corresponding length from other localities. The Lake Michigan kiyi grows slowly, with the females growing slightly more rapidly than the males. The grand average calculated lengths indicated, for example, that the females did not attain a total length of 10 inches until the fifth year of life or the males until the sixth. Similarly, the calculated weight of 4 ounces was not reached until the fifth or sixth year (with the actual time varying with sex and locality). The season's growth of the kiyi probably begins sometime in May and most or all of the growth is completed by the end of August. The calculated lengths of the age groups exhibited large discrepancies that differed from “Lee's phenomenon” as ordinarily observed in that the data for the later rather than the earlier years of life were affected most severely. Chief among the factors held responsible for these discrepancies were gear selection and the selective destruction of the more rapidly growing individuals in the fishery. Errors inherent in the (direct-proportion) method of computing growth from scale measurements were considered to have been unimportant. The Lake Michigan kiyi exhibits growth compensation–the tendency for the smaller of the young fish to have the more rapid growth in the later years of life. Comparisons with the average lengths and weights of the age groups of the Lake Ontario kiyi given by Pritchard (1931) indicated the Lake Michigan fish to be the larger at the earlier ages (age-groups II and III) and the smaller at the later ages (age-groups IV to VI). The length-frequency distributions of the age groups exhibited extensive overlap. As many as eight age groups were represented in a single centimeter interval of length. The length frequencies and average lengths of all fish collected, arranged according to the mesh sizes of the gill nets by which they were captured, revealed that the selective action of these nets in the taking of kiyis was much more obvious in the numbers of fish in the catch than in their average size. As an illustration, in 1930–1931, the 2 3/4-inch mesh nets took fish that were only 0.1 inch longer than those in 2 1/2-inch meshes but captured less than one fourth as many. Gill nets fished in northern Lake Michigan in 1932 captured kiyis that averaged 0.2 to 0.4 inch longer than those taken in the same meshes in southern Lake Michigan in 1930–1931. Because of the more slender form of kiyis from the northeastern island region of Lake Michigan, data on the general length weight relationship were compiled separately for fish of that area and for those of the great central basins of the lake. In both regions the weight increased to a power slightly greater than the cube of the length. Available information on condition indicated that the coefficient (K) was higher in August and early September than in May, June, and July. Condition declined from early September to October and early November–the latter period the time of most active spawning. Spawning itself was accompanied by an additional loss of about 12 per cent of the body weight of females and of somewhat less than 2 per cent of the weight of males. Analysis of the variations of K within a group that was homogeneous with respect to age, sex, maturity, and time of collection revealed that a net of a particular mesh size tends to take the heavier of the shorter fish and the lighter of the longer fish within its range of effectiveness. Among fish of the same length the values of K tended to increase with increase in the mesh size of the nets employed for their capture. Practically all fish in the samples were mature (only 11 immature in more than 6,000). These “immature” fish were probably “non-functional” since all of them approached or exceeded the average length of the mature kiyis. Females were strongly predominant in the collections at all seasons but were relatively more plentiful during the summer (90 per cent of the total) than during the spawning period (75 per cent). Possible factors contributing to this predominance of females and to the change in the sex ratio at the spawning season were discussed. A decrease in the relative abundance of males with increase in age appears to be characteristic of the kiyi. This decrease indicates a differential mortality of th sexes (greater relative destruction of males in the spawning period when they are unusually abundant or a greater natural mortality rate for the males). Current fishery regulations on mesh size and closed seasons afford the kiyi good protection but offer no guarantee against depletion from too intensive fishing.
El-Adl, Gamal; Hassanin, Ehab Y.; Abdellatif, M-Serry
2010-01-01
The objective of this study was to evaluate the outcome of semi-open reduction and minimal internal fixation through a single small lateral approach as a minimally invasive technique for treatment of displaced intra-articular calcaneal fractures. This prospective study was conducted on eighteen patients (16 men and 2 women). The average age was 37.7 (22–55). The most common cause of injury was a fall from height in fourteen patients. Patients were operated on within a mean time of 4.8 days of admission (1–11 days) and were followed up for an average period of 24.1 months (6–39 months). Patients were evaluated clinically using the Creighton-Nebraska Heath Foundation Assessment score of Crosby and Fitzgibbons (J Bone Joint Surg (Am) 72-A:852–859, 1990). The scoring system proposed by Knirk and Jupiter was used for radiological assessment of the posterior subtalar joint (Knirk and Jupiter in J Bone Joint Surg (Am) 68-A: 647–659, 1986). The skin incision healed in all cases without necrosis, infection, or sural nerve injury. All fractures healed after an average of 8 weeks (7–10 weeks), and patients returned to the routine daily activities after an average time of 4.3 months (3–7 months). In conclusion, semi-open reduction and minimal internal fixation through a small lateral approach is an effective treatment for carefully selected cases of displaced intra-articular calcaneal fractures. PMID:21811904
Analysis of Muscle Contraction on Pottery Manufacturing Process Using Electromyography (EMG)
NASA Astrophysics Data System (ADS)
Soewardi, Hartomo; Azka Rahmayani, Amalia
2016-01-01
One of the most common problems in pottery manufacturing process is musculoskeletal disorders on workers. This disorder was caused by uncomfortable posture where the workers sit on the floor with one leg was folded and another was twisted for long duration. Back, waist, buttock, and right knee frequently experience the disorders. The objective of this research is to investigate the muscle contraction at such body part of workers in manufacturing process of pottery. Electromyography is used to investigate the muscle contraction based on the median frequency signal. Focus measurements is conducted on four muscles types. They are lower interscapular muscle on the right and left side, dorsal lumbar muscle, and lateral hamstring muscle. Statistical analysis is conducted to test differences of muscle contraction between female and male. The result of this research showed that the muscle which reached the highest contraction is dorsal lumbar muscle with the average of median frequency is 51,84 Hz. Then followed by lower interscapular muscle on the left side with the average of median frequency is 31,30 hz, lower interscapular muscle on the right side average of median frequency is 31,24 Hz, and lateral hamstring muscle average of median frequency is 21,77 Hz. Based on the statistic analysis result, there were no differences between male and female on left and right lower interscapular muscle and dorsal lumbar muscle but there were differences on lateral hamstring muscle with the significance level is 5%. Besides that, there were differences for all combination muscle types with the level of significance is 5%.
Experimental investigation of lateral forces induced by flow through model labyrinth glands
NASA Technical Reports Server (NTRS)
Leong, Y. M. M. S.; Brown, R. D.
1984-01-01
The lateral forces induced by flow through model labyrinth glands were investigated. Circumferential pressure distributions, lateral forces and stiffness coefficients data obtained are discussed. The force system is represented as a negative spring and a tangential force orthogonal to eccentricity. The magnitude of these forces are dependent on eccentricity, entry swirl, rotor peripheral velocity and seal size. A pressure equalization chamber at midgland tests should in significantly reduced forces and stiffness coefficients.
Nadkarni, Tanvi N.; Andreoli, Matthew J.; Nair, Veena A.; Yin, Peng; Young, Brittany M.; Kundu, Bornali; Pankratz, Joshua; Radtke, Andrew; Holdsworth, Ryan; Kuo, John S.; Field, Aaron S.; Baskaya, Mustafa K.; Moritz, Chad H.; Meyerand, M. Elizabeth; Prabhakaran, Vivek
2014-01-01
Background and purpose Functional magnetic resonance imaging (fMRI) is a non-invasive pre-surgical tool used to assess localization and lateralization of language function in brain tumor and vascular lesion patients in order to guide neurosurgeons as they devise a surgical approach to treat these lesions. We investigated the effect of varying the statistical thresholds as well as the type of language tasks on functional activation patterns and language lateralization. We hypothesized that language lateralization indices (LIs) would be threshold- and task-dependent. Materials and methods Imaging data were collected from brain tumor patients (n = 67, average age 48 years) and vascular lesion patients (n = 25, average age 43 years) who received pre-operative fMRI scanning. Both patient groups performed expressive (antonym and/or letter-word generation) and receptive (tumor patients performed text-reading; vascular lesion patients performed text-listening) language tasks. A control group (n = 25, average age 45 years) performed the letter-word generation task. Results Brain tumor patients showed left-lateralization during the antonym-word generation and text-reading tasks at high threshold values and bilateral activation during the letter-word generation task, irrespective of the threshold values. Vascular lesion patients showed left-lateralization during the antonym and letter-word generation, and text-listening tasks at high threshold values. Conclusion Our results suggest that the type of task and the applied statistical threshold influence LI and that the threshold effects on LI may be task-specific. Thus identifying critical functional regions and computing LIs should be conducted on an individual subject basis, using a continuum of threshold values with different tasks to provide the most accurate information for surgical planning to minimize post-operative language deficits. PMID:25685705
Zhao, Lei; Liu, Han; He, Zhihong; Dong, Shikui
2018-05-14
Multiband metamaterial perfect absorbers (MPAs) have promising applications in many fields like microbolometers, infrared detection, biosensing, and thermal emitters. In general, the single resonator can only excite a fundamental mode and achieve single absorption band. The multiband MPA can be achieved by combining several different sized resonators together. However, it's still challenging to design the MPA with absorption bands of more than four and average absorptivity of more than 90% due to the interaction between differently sized resonators. In this paper, three absorption bands are successfully achieved with average absorptivity up to 98.5% only utilizing single one our designed ring-strip resonator, which can simultaneously excite a fundamental electric dipole mode, a higher-order electric quadrupole mode, and a higher-order electric octopole mode. As the biosensor, the sensing performance of the higher-order modes is higher than the fundamental modes. Then we try to increase the absorption bands by combining different sized ring-strip resonators together and make the average absorptivity above 90% by optimizing the geometry parameters. A six-band MPA is achieved by combining two different sized ring-strip resonators with average absorptivity up to 98.8%, which can excite two dipole modes, two quadrupole modes, and two octopole modes. A twelve-band MPA is achieved by combining four different sized ring-strip resonators with average absorptivity up to 93.7%, which can excite four dipole modes, four quadrupole modes, and four octopole modes.
Jelenkovic, Aline; Yokoyama, Yoshie; Sund, Reijo; Hur, Yoon-Mi; Harris, Jennifer R; Brandt, Ingunn; Nilsen, Thomas Sevenius; Ooki, Syuichi; Ullemar, Vilhelmina; Almqvist, Catarina; Magnusson, Patrik K E; Saudino, Kimberly J; Stazi, Maria A; Fagnani, Corrado; Brescianini, Sonia; Nelson, Tracy L; Whitfield, Keith E; Knafo-Noam, Ariel; Mankuta, David; Abramson, Lior; Cutler, Tessa L; Hopper, John L; Llewellyn, Clare H; Fisher, Abigail; Corley, Robin P; Huibregtse, Brooke M; Derom, Catherine A; Vlietinck, Robert F; Bjerregaard-Andersen, Morten; Beck-Nielsen, Henning; Sodemann, Morten; Krueger, Robert F; McGue, Matt; Pahlen, Shandell; Alexandra Burt, S; Klump, Kelly L; Dubois, Lise; Boivin, Michel; Brendgen, Mara; Dionne, Ginette; Vitaro, Frank; Willemsen, Gonneke; Bartels, Meike; van Beijsterveld, Catharina E M; Craig, Jeffrey M; Saffery, Richard; Rasmussen, Finn; Tynelius, Per; Heikkilä, Kauko; Pietiläinen, Kirsi H; Bayasgalan, Gombojav; Narandalai, Danshiitsoodol; Haworth, Claire M A; Plomin, Robert; Ji, Fuling; Ning, Feng; Pang, Zengchang; Rebato, Esther; Tarnoki, Adam D; Tarnoki, David L; Kim, Jina; Lee, Jooyeon; Lee, Sooji; Sung, Joohon; Loos, Ruth J F; Boomsma, Dorret I; Sørensen, Thorkild I A; Kaprio, Jaakko; Silventoinen, Karri
2018-05-01
There is evidence that birth size is positively associated with height in later life, but it remains unclear whether this is explained by genetic factors or the intrauterine environment. To analyze the associations of birth weight, length and ponderal index with height from infancy through adulthood within mono- and dizygotic twin pairs, which provides insights into the role of genetic and environmental individual-specific factors. This study is based on the data from 28 twin cohorts in 17 countries. The pooled data included 41,852 complete twin pairs (55% monozygotic and 45% same-sex dizygotic) with information on birth weight and a total of 112,409 paired height measurements at ages ranging from 1 to 69 years. Birth length was available for 19,881 complete twin pairs, with a total of 72,692 paired height measurements. The association between birth size and later height was analyzed at both the individual and within-pair level by linear regression analyses. Within twin pairs, regression coefficients showed that a 1-kg increase in birth weight and a 1-cm increase in birth length were associated with 1.14-4.25 cm and 0.18-0.90 cm taller height, respectively. The magnitude of the associations was generally greater within dizygotic than within monozygotic twin pairs, and this difference between zygosities was more pronounced for birth length. Both genetic and individual-specific environmental factors play a role in the association between birth size and later height from infancy to adulthood, with a larger role for genetics in the association with birth length than with birth weight. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Antony, Benny; Ding, Changhai; Stannus, Oliver; Cicuttini, Flavia; Jones, Graeme
2011-09-01
To determine the association of knee bone size, cartilage volume, and body mass index (BMI) at baseline with knee cartilage loss over 2 years in younger or middle-aged adults. A total of 324 subjects (mean age 45 yrs, range 26-61) were measured at baseline and about 2 years later. Knee cartilage volume and bone size were determined using T1-weighted fat-saturated magnetic resonance imaging. In multivariable analysis, baseline knee bone size was negatively associated with annual change in knee cartilage volume at medial and lateral tibial sites (ß = -0.62% to -0.47%/cm(2), all p < 0.001). The associations disappeared at medial tibial site after adjustment for baseline cartilage volume and became of borderline statistical significance at lateral tibial site after adjustment for both baseline cartilage volume and osteophytes (ß = -0.29, p = 0.059). Baseline knee cartilage volume was consistently and negatively associated with annual change in knee cartilage volume at all 3 medial tibial, lateral tibial, and patellar sites (ß = -4.41% to -1.37%/ml, all p < 0.001). Baseline BMI was negatively associated with an annual change in knee cartilage volume, but only in subjects within the upper tertile of baseline cartilage volume, even after adjusting for cartilage defects (ß = -0.16% to -0.34%/kg/m(2), all p < 0.05). Our study suggests that both higher baseline tibial bone area and knee cartilage volume (most likely due to cartilage swelling) are associated with greater knee cartilage loss over 2 years. A higher BMI was associated with greater knee cartilage loss only in subjects with higher baseline cartilage volume.
NASA Astrophysics Data System (ADS)
Milledge, David; Bellugi, Dino; McKean, Jim; Dietrich, William E.
2013-04-01
Current practice in regional-scale shallow landslide hazard assessment is to adopt a one-dimensional slope stability representation. Such a representation cannot produce discrete landslides and thus cannot make predictions on landslide size. Furthermore, one-dimensional approaches cannot include lateral effects, which are known to be important in defining instability. Here we derive an alternative model that accounts for lateral resistance by representing the forces acting on each margin of an unstable block of soil. We model boundary frictional resistances using 'at rest' earth pressure on the lateral sides, and 'active' and 'passive' pressure, using the log-spiral method, on the upslope and downslope margins. We represent root reinforcement on each margin assuming that root cohesion declines exponentially with soil depth. We test our model's ability to predict failure of an observed landslide where the relevant parameters are relatively well constrained and find that our model predicts failure at the observed location and predicts that larger or smaller failures conformal to the observed shape are indeed more stable. We use a sensitivity analysis of the model to show that lateral reinforcement sets a minimum landslide size, and that the additional strength at the downslope boundary results in optimal shapes that are longer in the downslope direction. However, reinforcement effects alone cannot fully explain the size or shape distributions of observed landslides, highlighting the importance of the spatial pattern of key parameters (e.g. pore water pressure and soil depth) at the watershed scale. The application of the model at this scale requires an efficient method to find unstable shapes among an exponential number of candidates. In this context, the model allows a more extensive examination of the controls on landslide size, shape and location.
Chang, Tzyy-Shuh; Huang, Hsun-Hau; Lin, Chang-Hung
2007-10-02
An adjustable guide, includes two or more mechanisms each having a rotatable retaining element containing a retaining groove with a variable radius in its perimeter surface. The grooves form a guidance path to control the lateral, i.e. non-axial, motion of a long bar moving along a longitudinal axis during a production process.The diameter of the guidance path varies according to the variable radii of the grooves. The guidance path increases in size at a predetermined rate, from a point of origin to an end point on the retaining groove. Rotating the retaining elements causes the diameter of the retaining grooves to change so that the size of the guidance path can be changed to match the diameter of the bar being rolled, size of the guidance path can be changed to fit the diameter of a new bar rolled without having to exchange the guide for a different sized guide, reduce fiction between the bar and the guide, a media, such as compressed air, can be injected between the retaining elements via orifices.Each retaining element is attached to a mounting apparatus. The mounting apparatus can be fixed or flexible. The flexible mounting apparatus includes one or more springs and one or more shock absorbers. A force neutral position of the flexible mounting apparatus is designed to be located on the predetermined ideal bar path line. The flexible mounting apparatus dissipates kinetic energy from the bar thereby reducing the bar's lateral motion relative to the ideal bar path line.The damping ratio of the mounting apparatus can be adjustable to alter the product's vibration mode to enable better control of the bar's lateral motion.
A procedure to determine the planar integral spot dose values of proton pencil beam spots
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anand, Aman; Sahoo, Narayan; Zhu, X. Ronald
2012-02-15
Purpose: Planar integral spot dose (PISD) of proton pencil beam spots (PPBSs) is a required input parameter for beam modeling in some treatment planning systems used in proton therapy clinics. The measurement of PISD by using commercially available large area ionization chambers, like the PTW Bragg peak chamber (BPC), can have large uncertainties due to the size limitation of these chambers. This paper reports the results of our study of a novel method to determine PISD values from the measured lateral dose profiles and peak dose of the PPBS. Methods: The PISDs of 72.5, 89.6, 146.9, 181.1, and 221.8 MeVmore » energy PPBSs were determined by area integration of their planar dose distributions at different depths in water. The lateral relative dose profiles of the PPBSs at selected depths were measured by using small volume ion chambers and were investigated for their angular anisotropies using Kodak XV films. The peak spot dose along the beam's central axis (D{sub 0}) was determined by placing a small volume ion chamber at the center of a broad field created by the superposition of spots at different locations. This method allows eliminating positioning uncertainties and the detector size effect that could occur when measuring it in single PPBS. The PISD was then calculated by integrating the measured lateral relative dose profiles for two different upper limits of integration and then multiplying it with corresponding D{sub 0}. The first limit of integration was set to radius of the BPC, namely 4.08 cm, giving PISD{sub RBPC}. The second limit was set to a value of the radial distance where the profile dose falls below 0.1% of the peak giving the PISD{sub full}. The calculated values of PISD{sub RBPC} obtained from area integration method were compared with the BPC measured values. Long tail dose correction factors (LTDCFs) were determined from the ratio of PISD{sub full}/PISD{sub RBPC} at different depths for PPBSs of different energies. Results: The spot profiles were found to have angular anisotropy. This anisotropy in PPBS dose distribution could be accounted in a reasonable approximate manner by taking the average of PISD values obtained using the in-line and cross-line profiles. The PISD{sub RBPC} values fall within 3.5% of those measured by BPC. Due to inherent dosimetry challenges associated with PPBS dosimetry, which can lead to large experimental uncertainties, such an agreement is considered to be satisfactory for validation purposes. The PISD{sub full} values show differences ranging from 1 to 11% from BPC measured values, which are mainly due to the size limitation of the BPC to account for the dose in the long tail regions of the spots extending beyond its 4.08 cm radius. The dose in long tail regions occur both for high energy beams such as 221.8 MeV PPBS due to the contributions of nuclear interactions products in the medium, and for low energy PPBS because of their larger spot sizes. The calculated LTDCF values agree within 1% with those determined by the Monte Carlo (MC) simulations. Conclusions: The area integration method to compute the PISD from PPBS lateral dose profiles is found to be useful both to determine the correction factors for the values measured by the BPC and to validate the results from MC simulations.« less
NASA Technical Reports Server (NTRS)
Molnar, P.; Chen, W.-P.
1984-01-01
S-P wave travel time residuals were measured in earthquakes in Tibet and the Himalaya in order to study lateral inhomogeneities in the earth's mantle. Average S-P residuals, measured with respect to Jeffrey-Bullen (J-B) tables for 11 earthquakes in the Himalaya are less than +1 second. Average J-B S-P from 10 of 11 earthquakes in Tibet, however, are greater than +1 second even when corrected for local crustal thickness. The largest values, ranging between 2.5 and 4.9 seconds are for five events in central and northern Tibet, and they imply that the average velocities in the crust and upper mantle in this part of Tibet are 4 to 10 percent lower than those beneath the Himalaya. On the basis of the data, it is concluded that it is unlikely that a shield structure lies beneath north central Tibet unless the S-P residuals are due to structural variations occurring deeper than 250 km.
Talonavicular joint arthroscopic portals: A cadaveric study of feasibility and safety.
Xavier, Gabriel; Oliva, Xavier Martin; Rotinen, Mauri; Monzo, Mariano
2016-09-01
The objectives of the study were to evaluate the safety of hypothetical arthroscopic portals from talonavicular joint and to evaluate their reproducibility and enforceability. 19 cadaveric feet were marked and four arthroscopic portals were made (medial, dorsomedial, dorsolateral and lateral). The specimens were dissected in layers and the distances between neurovascular structures and the trocars were measured. Medial and dorsomedial portals were in average 8.3 and 8.7, respectively, to the saphenous vein and nerve. Dorsolateral portal was in average 8.1mm to the deep peroneal nerve and dorsalis pedis artery, and 9.1mm to the medial dorsal cutaneous branch of the superficial peroneal nerve. Lateral portal was in average 12.3mm to the intermediate dorsal cutaneous branch of the superficial peroneal nerve. Tested portals shown to have a good safety margin for the foot neurovascular deep dorsal structures and an acceptable safety margin for the superficial neurovascular structures. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Qin, Li; Dong, Li-Li; Xu, Wen-Hai; Zhang, Li-Dong; Leon, Arturo S
2018-04-02
The aim of this study was to investigate how vehicle speed influences the characteristics of driver's eye movement at highway tunnel entrances during day and night. In this study, six drivers' eye movement data (from 200 m before tunnel entrance to 200 m inside tunnel entrance) under five predetermined vehicle speeds (40, 50, 60, 70 and 80 km/h) in the daytime and three predetermined vehicle speeds (40, 60 and 80 km/h) in the nighttime were recorded using the non-intrusive Dikablis Professional eye-tracking system. Pupil size, the average fixation duration time and the average number of fixation were analyzed and then the influence of the vehicle speed on these parameters was evaluated by means of IBM SPSS Statistics 20.0. The results for pupil size in daytime increased when approaching the tunnel entrance, while as for nighttime, pupil size decreased when approaching the tunnel entrance and then increased after entering the tunnel. The pupil size in daytime has a significant negative correlation with vehicle speed, while the pupil size in nighttime did not show a significant association with vehicle speed. Furthermore, the average fixation duration in daytime increased when entering the tunnel, and had a significant negative correlation with vehicle speed. Also, the average number of fixations in daytime decreased when entering the tunnel and has a significant negative correlation with vehicle speed. However, the average fixation duration and the average number of fixations in nighttime did not show any significant association with vehicle speed. Moreover, limitations and future directions of the study are discussed for the further investigation.
Dong, Li-Li; Xu, Wen-Hai; Zhang, Li-Dong; Leon, Arturo S.
2018-01-01
The aim of this study was to investigate how vehicle speed influences the characteristics of driver’s eye movement at highway tunnel entrances during day and night. In this study, six drivers’ eye movement data (from 200 m before tunnel entrance to 200 m inside tunnel entrance) under five predetermined vehicle speeds (40, 50, 60, 70 and 80 km/h) in the daytime and three predetermined vehicle speeds (40, 60 and 80 km/h) in the nighttime were recorded using the non-intrusive Dikablis Professional eye-tracking system. Pupil size, the average fixation duration time and the average number of fixation were analyzed and then the influence of the vehicle speed on these parameters was evaluated by means of IBM SPSS Statistics 20.0. The results for pupil size in daytime increased when approaching the tunnel entrance, while as for nighttime, pupil size decreased when approaching the tunnel entrance and then increased after entering the tunnel. The pupil size in daytime has a significant negative correlation with vehicle speed, while the pupil size in nighttime did not show a significant association with vehicle speed. Furthermore, the average fixation duration in daytime increased when entering the tunnel, and had a significant negative correlation with vehicle speed. Also, the average number of fixations in daytime decreased when entering the tunnel and has a significant negative correlation with vehicle speed. However, the average fixation duration and the average number of fixations in nighttime did not show any significant association with vehicle speed. Moreover, limitations and future directions of the study are discussed for the further investigation. PMID:29614793
Volcanic hazards from Bezymianny- and Bandai-type eruptions
Siebert, L.; Glicken, H.; Ui, T.
1987-01-01
Major slope failures are a significant degradational process at volcanoes. Slope failures and associated explosive eruptions have resulted in more than 20 000 fatalities in the past 400 years; the historic record provides evidence for at least six of these events in the past century. Several historic debris avalanches exceed 1 km3 in volume. Holocene avalanches an order of magnitude larger have traveled 50-100 km from the source volcano and affected areas of 500-1500 km2. Historic eruptions associated with major slope failures include those with a magmatic component (Bezymianny type) and those solely phreatic (Bandai type). The associated gravitational failures remove major segments of the volcanoes, creating massive horseshoe-shaped depressions commonly of caldera size. The paroxysmal phase of a Bezymianny-type eruption may include powerful lateral explosions and pumiceous pyroclastic flows; it is often followed by construction of lava dome or pyroclastic cone in the new crater. Bandai-type eruptions begin and end with the paroxysmal phase, during which slope failure removes a portion of the edifice. Massive volcanic landslides can also occur without related explosive eruptions, as at the Unzen volcano in 1792. The main potential hazards from these events derive from lateral blasts, the debris avalanche itself, and avalanche-induced tsunamis. Lateral blasts produced by sudden decompression of hydrothermal and/or magmatic systems can devastate areas in excess of 500km2 at velocities exceeding 100 m s-1. The ratio of area covered to distance traveled for the Mount St. Helens and Bezymianny lateral blasts exceeds that of many pyroclastic flows or surges of comparable volume. The potential for large-scale lateral blasts is likely related to the location of magma at the time of slope failure and appears highest when magma has intruded into the upper edifice, as at Mount St. Helens and Bezymianny. Debris avalanches can move faster than 100 ms-1 and travel tens of kilometers. When not confined by valley walls, avalanches can affect wide areas beyond the volcano's flanks. Tsunamis from debris avalanches at coastal volcanoes have caused more fatalities than have the landslides themselves or associated eruptions. The probable travel distance (L) of avalanches can be estimated by considering the potential vertical drop (H). Data from a catalog of around 200 debris avalanches indicates that the H/L rations for avalanches with volumes of 0.1-1 km3 average 0.13 and range 0.09-0.18; for avalanches exceeding 1 km3, H/L ratios average 0.09 and range 0.5-0.13. Large-scale deformation of the volcanic edefice and intense local seismicity precede many slope failures and can indicate the likely failure direction and orientation of potential lateral blasts. The nature and duration of precursory activity vary widely, and the timing of slope faliure greatly affects the type of associated eruption. Bandai-type eruptions are particularly difficult to anticipate because they typically climax suddenly without precursory eruptions and may be preceded by only short periods of seismicity. ?? 1987 Springer-Verlag.
Regional climate model sensitivity to domain size
NASA Astrophysics Data System (ADS)
Leduc, Martin; Laprise, René
2009-05-01
Regional climate models are increasingly used to add small-scale features that are not present in their lateral boundary conditions (LBC). It is well known that the limited area over which a model is integrated must be large enough to allow the full development of small-scale features. On the other hand, integrations on very large domains have shown important departures from the driving data, unless large scale nudging is applied. The issue of domain size is studied here by using the “perfect model” approach. This method consists first of generating a high-resolution climatic simulation, nicknamed big brother (BB), over a large domain of integration. The next step is to degrade this dataset with a low-pass filter emulating the usual coarse-resolution LBC. The filtered nesting data (FBB) are hence used to drive a set of four simulations (LBs for Little Brothers), with the same model, but on progressively smaller domain sizes. The LB statistics for a climate sample of four winter months are compared with BB over a common region. The time average (stationary) and transient-eddy standard deviation patterns of the LB atmospheric fields generally improve in terms of spatial correlation with the reference (BB) when domain gets smaller. The extraction of the small-scale features by using a spectral filter allows detecting important underestimations of the transient-eddy variability in the vicinity of the inflow boundary, which can penalize the use of small domains (less than 100 × 100 grid points). The permanent “spatial spin-up” corresponds to the characteristic distance that the large-scale flow needs to travel before developing small-scale features. The spin-up distance tends to grow in size at higher levels in the atmosphere.
Baby Sign but Not Spontaneous Gesture Predicts Later Vocabulary in Children with Down Syndrome
ERIC Educational Resources Information Center
Özçaliskan, Seyda; Adamson, Lauren B.; Dimitrova, Nevena; Bailey, Jhonelle; Schmuck, Lauren
2016-01-01
Early spontaneous gesture, specifically deictic gesture, predicts subsequent vocabulary development in typically developing (TD) children. Here, we ask whether deictic gesture plays a similar role in predicting later vocabulary size in children with Down Syndrome (DS), who have been shown to have difficulties in speech production, but strengths in…
Appiani, Elena; Page, Sarah E; McNeill, Kristopher
2014-10-21
Dissolved organic matter (DOM) is involved in numerous environmental processes, and its molecular size is important in many of these processes, such as DOM bioavailability, DOM sorptive capacity, and the formation of disinfection byproducts during water treatment. The size and size distribution of the molecules composing DOM remains an open question. In this contribution, an indirect method to assess the average size of DOM is described, which is based on the reaction of hydroxyl radical (HO(•)) quenching by DOM. HO(•) is often assumed to be relatively unselective, reacting with nearly all organic molecules with similar rate constants. Literature values for HO(•) reaction with organic molecules were surveyed to assess the unselectivity of DOM and to determine a representative quenching rate constant (k(rep) = 5.6 × 10(9) M(-1) s(-1)). This value was used to assess the average molecular weight of various humic and fulvic acid isolates as model DOM, using literature HO(•) quenching constants, kC,DOM. The results obtained by this method were compared with previous estimates of average molecular weight. The average molecular weight (Mn) values obtained with this approach are lower than the Mn measured by other techniques such as size exclusion chromatography (SEC), vapor pressure osmometry (VPO), and flow field fractionation (FFF). This suggests that DOM is an especially good quencher for HO(•), reacting at rates close to the diffusion-control limit. It was further observed that humic acids generally react faster than fulvic acids. The high reactivity of humic acids toward HO(•) is in line with the antioxidant properties of DOM. The benefit of this method is that it provides a firm upper bound on the average molecular weight of DOM, based on the kinetic limits of the HO(•) reaction. The results indicate low average molecular weight values, which is most consistent with the recent understanding of DOM. A possible DOM size distribution is discussed to reconcile the small nature of DOM with the large-molecule behavior observed in other studies.
Takeuchi, Yuichi; Hori, Michio; Tada, Shinya; Oda, Yoichi
2016-01-01
The scale-eating cichlid Perissodus microlepis with asymmetric mouth is an attractive model of behavioral laterality: each adult tears off scales from prey fishes’ left or right flanks according to the direction in which its mouth is skewed. To investigate the development of behavioral laterality and mouth asymmetry, we analyzed stomach contents and lower jaw-bone asymmetry of various-sized P. microlepis (22≤SL<115mm) sampled in Lake Tanganyika. The shapes of the pored scales found in each specimen’s stomach indicated its attack side preference. Early-juvenile specimens (SL<45mm) feeding mainly on zooplankton exhibited slight but significant mouth asymmetry. As the fish acquired scale-eating (45mm≤SL), attack side preference was gradually strengthened, as was mouth asymmetry. Among size-matched individuals, those with more skewed mouths ate more scales. These findings show that behavioral laterality in scale-eating P. microlepis is established in association with development of mouth asymmetry which precedes the behavioral acquisition, and that this synergistic interaction between physical and behavioral literalities may contribute to efficient scale-eating. PMID:26808293
Correlating hydrodynamic radii with that of two-dimensional nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yue, Yuan; Kan, Yuwei; Clearfield, Abraham
2015-12-21
Dynamic light scattering (DLS) is one of the most adapted methods to measure the size of nanoparticles, as referred to the hydrodynamic radii (R{sub h}). However, the R{sub h} represents only that of three-dimensional spherical nanoparticles. In the present research, the size of two-dimensional (2D) nanoparticles of yttrium oxide (Y{sub 2}O{sub 3}) and zirconium phosphate (ZrP) was evaluated through comparing their hydrodynamic diameters via DLS with lateral sizes obtained using scanning and transmission electron microscopy. We demonstrate that the hydrodynamic radii are correlated with the lateral sizes of both square and circle shaped 2D nanoparticles. Two proportional coefficients, i.e., correctingmore » factors, are proposed for the Brownian motion status of 2D nanoparticles. The correction is possible by simplifying the calculation of integrals in the case of small thickness approximation. The correcting factor has great significance for investigating the translational diffusion behavior of 2D nanoparticles in a liquid and in effective and low-cost measurement in terms of size and morphology of shape-specific nanoparticles.« less
Pathak, Arup Kumar; Samanta, Alok Kumar; Maity, Dilip Kumar
2011-04-07
We report conformationally averaged VDEs (VDE(w)(n)) for different sizes of NO(3)(-)·nH(2)O clusters calculated by using uncorrelated HF, correlated hybrid density functional (B3LYP, BHHLYP) and correlated ab intio (MP2 and CCSD(T)) theory. It is observed that the VDE(w)(n) at the B3LYP/6-311++G(d,p), B3LYP/Aug-cc-Pvtz and CCSD(T)/6-311++G(d,p) levels is very close to the experimentally measured VDE. It is shown that the use of calculated results of the conformationally averaged VDE for small-sized solvated negatively-charged clusters and a microscopic theory-based general expression for the same provides a route to obtain the VDE for a wide range of cluster sizes, including bulk.
Modeling of mixing processes: Fluids, particulates, and powders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ottino, J.M.; Hansen, S.
Work under this grant involves two main areas: (1) Mixing of Viscous Liquids, this first area comprising aggregation, fragmentation and dispersion, and (2) Mixing of Powders. In order to produce a coherent self-contained picture, we report primarily on results obtained under (1), and within this area, mostly on computational studies of particle aggregation in regular and chaotic flows. Numerical simulations show that the average cluster size of compact clusters grows algebraically, while the average cluster size of fractal clusters grows exponentially; companion mathematical arguments are used to describe the initial growth of average cluster size and polydispersity. It is foundmore » that when the system is well mixed and the capture radius independent of mass, the polydispersity is constant for long-times and the cluster size distribution is self-similar. Furthermore, our simulations indicate that the fractal nature of the clusters is dependent upon the mixing.« less
Toth, Damon J. A.; Leecaster, Molly; Pettey, Warren B. P.; Gundlapalli, Adi V.; Gao, Hongjiang; Rainey, Jeanette J.; Uzicanin, Amra; Samore, Matthew H.
2015-01-01
Influenza poses a significant health threat to children, and schools may play a critical role in community outbreaks. Mathematical outbreak models require assumptions about contact rates and patterns among students, but the level of temporal granularity required to produce reliable results is unclear. We collected objective contact data from students aged 5–14 at an elementary school and middle school in the state of Utah, USA, and paired those data with a novel, data-based model of influenza transmission in schools. Our simulations produced within-school transmission averages consistent with published estimates. We compared simulated outbreaks over the full resolution dynamic network with simulations on networks with averaged representations of contact timing and duration. For both schools, averaging the timing of contacts over one or two school days caused average outbreak sizes to increase by 1–8%. Averaging both contact timing and pairwise contact durations caused average outbreak sizes to increase by 10% at the middle school and 72% at the elementary school. Averaging contact durations separately across within-class and between-class contacts reduced the increase for the elementary school to 5%. Thus, the effect of ignoring details about contact timing and duration in school contact networks on outbreak size modelling can vary across different schools. PMID:26063821
Roemer, Frank W; Jomaah, Nabil; Niu, Jingbo; Almusa, Emad; Roger, Bernard; D'Hooghe, Pieter; Geertsema, Celeste; Tol, Johannes L; Khan, Karim; Guermazi, Ali
2014-07-01
Ankle joint injuries are extremely common sports injuries, with the anterior talofibular ligament involved in the majority of ankle sprains. There have been only a few large magnetic resonance imaging (MRI) studies on associated structural injuries after ankle sprains. To describe the injury pattern in athletes who were referred to MRI for the assessment of an acute ankle sprain and to assess the risk of associated traumatic tissue damage including lateral and syndesmotic ligament involvement. Cross-sectional study; Level of evidence, 3. A total of 261 ankle MRI scans of athletes with acute ankle sprains were evaluated for: lateral and syndesmotic ligament injury; concomitant injuries to the deltoid and spring ligaments and sinus tarsi; peroneal, flexor, and extensor retinacula and tendons; traumatic and nontraumatic osteochondral and osseous changes; and joint effusion. Patients were on average 22.5 years old, and the average time from injury to MRI was 5.7 days. Six exclusive injury patterns were defined based on lateral and syndesmotic ligament involvement. The risk for associated injuries was assessed by logistic regression using ankles with no or only low-grade lateral ligament injuries and no syndesmotic ligament damage as the reference. With regard to the injury pattern, there were 103 ankles (39.5%) with complete anterior talofibular ligament disruption and no syndesmotic injury, and 53 ankles (20.3%) had a syndesmotic injury with or without lateral ligament damage. Acute osteochondral lesions of the lateral talar dome were seen in 20 ankles (7.7%). The percentage of chronic lateral osteochondral lesions was 1.1%. The risk for talar bone contusions increased more than 3-fold for ankles with complete lateral ligament ruptures (adjusted odds ratio [aOR], 3.43; 95% CI, 1.72-6.85) but not for ankles with syndesmotic involvement. The risk for associated deltoid ligament injuries increased for ankles with complete lateral ligament injuries (aOR, 4.04; 95% CI, 1.99-8.22) compared with patients with no or only low-grade lateral ligament injuries. About 20% of athletes referred for MRI after suffering an acute ankle sprain had evidence of a syndesmotic injury regardless of lateral ligament involvement, while more than half had evidence of any lateral ligament injury without syndesmotic involvement. Concomitant talar osseous and deltoid ligament injuries are common. © 2014 The Author(s).
Marple-Horvat, D E; Criado, J M; Armstrong, D M
1998-01-01
The discharge patterns of 166 lateral cerebellar neurones were studied in cats at rest and during visually guided stepping on a horizontal circular ladder. A hundred and twelve cells were tested against one or both of two visual stimuli: a brief full-field flash of light delivered during eating or rest, and a rung which moved up as the cat approached. Forty-five cells (40%) gave a short latency response to one or both of these stimuli. These visually responsive neurones were found in hemispheral cortex (rather than paravermal) and the lateral cerebellar nucleus (rather than nucleus interpositus).Thirty-seven cells (of 103 tested, 36%) responded to flash. The cortical visual response (mean onset latency 38 ms) was usually an increase in Purkinje cell discharge rate, of around 50 impulses s−1 and representing 1 or 2 additional spikes per trial (1.6 on average). The nuclear response to flash (mean onset latency 27 ms) was usually an increased discharge rate which was shorter lived and converted rapidly to a depression of discharge or return to control levels, so that there were on average only an additional 0.6 spikes per trial. A straightforward explanation of the difference between the cortical and nuclear response would be that the increased inhibitory Purkinje cell output cuts short the nuclear response.A higher proportion of cells responded to rung movement, sixteen of twenty-five tested (64%). Again most responded with increased discharge, which had longer latency than the flash response (first change in dentate output ca 60 ms after start of movement) and longer duration. Peak frequency changes were twice the size of those in response to flash, at 100 impulses s−1 on average and additional spikes per trial were correspondingly 3–4 times higher. Both cortical and nuclear responses were context dependent, being larger when the rung moved when the cat was closer than further away.A quarter of cells (20 of 84 tested, 24%) modulated their activity in advance of saccades, increasing their discharge rate. Four-fifths of these were non-reciprocally directionally selective. Saccade-related neurones were usually susceptible to other influences, i.e. their activity was not wholly explicable in terms of saccade parameters.Substantial numbers of visually responsive neurones also discharged in relation to stepping movements while other visually responsive neurones discharged in advance of saccadic eye movements. And more than half the cells tested were active in relation both to eye movements and to stepping movements. These combinations of properties qualify even individual cerebellar neurones to participate in the co-ordination of visually guided eye and limb movements. PMID:9490874
NASA Astrophysics Data System (ADS)
Patel, Vinay Kumar; Chauhan, Shivani; Katiyar, Jitendra Kumar
2018-04-01
In this study, a novel natural fiber i.e. Sour-weed botanically known as ‘Rumex acetosella’ has been first time introduced as natural reinforcements to polyester matrix. The natural fiber based polyester composites were fabricated by hand lay-up technique using different sizes and different weight percentages. In Sour-weed/Polyester composites, physical (density, water absorption and hardness), mechanical properties (tensile and impact properties) and wear properties (sand abrasion and sliding wear) were investigated for different sizes of sour weed of 0.6 mm, 5 mm, 10 mm, 15 mm and 20 mm at 3, 6 and 9 weight percent loading, respectively in polyester matrix. Furthermore, on average value of results, the multi-criteria optimization technique i.e. TOPSIS was employed to decide the ranking of the composites. From the optimized results, it was observed that Sour-weed composite reinforced with fiber’s size of 15 mm at 6 wt% loading demonstrated the best ranked composite exhibiting best overall properties as average tensile strength of 34.33 MPa, average impact strength of 10 Joule, average hardness of 12 Hv, average specific sand abrasion wear rate of 0.0607 mm3 N‑1m‑1, average specific sliding wear rate of 0.002 90 mm3 N‑1m‑1, average percentage of water absorption of 3.446% and average density of 1.013 among all fabricated composites.
A historical study of rural-to-urban migration in China: 1949-1985.
Zhao, Y; Liu, Q
1997-01-01
This paper reviews the literature on labor migration in China since the 1950s and examines the trends in rural-to-urban migration during the period of 1949 to the mid-1980s. Data were obtained from the 1986 sample survey on migration in 74 urban areas in China among 23,895 family households and 1643 collective households in 43 cities and 31 townships of 16 provinces. Non-farmers from rural areas were subtracted from total rural migrants. Non-farmers included recent urban high school graduates and party and government officials who were sent to rural areas during the Cultural Revolution and returned to cities. The sample included 53.3% men. The average age was 23.1 years. About 50% were married at the time of migration. The average educational attainment among persons aged over 15 years was 5.98 years. Reasons for migration included family reunion (49.7%), worker recruitment (28.5%), military recruitment (8.8%), and college attendance (3.0%). The volume of migration fluctuated greatly during 1949-85. During 1949-55, about 200 people in the 200,000 sample size migrated each year. During 1955-58, migrants numbered 459, 307, and 616, respectively. During the famine of 1959-61, migration dropped to 312, 292, and 124, respectively. 1961 was the lowest point of migration; 1958 was the highest point of migration before 1984. During the 1962-64 recovery period, migration remained low at under 200. During 1962-64, migrants totaled 200-300 persons. During the Cultural Revolution of 1967-68, migrants declined to under 200. During 1970-71, migrants increased to over 400 until 1979, when the number reached 576. The largest migration occurred during 1984-85 and peaked at 832 in 1985. The later years reflect a loosening of government policy. Migration followed political events closely. Migrants in later years were unlikely to attain urban resident status and benefits without fundamental policy changes.
Rechenberg, D K; Paqué, F
2013-06-01
To assess the impact of cross-sectional root canal shape (CSRCS) on the canal volume that can be filled and the root filling material that remains following a subsequent retreatment procedure. A total of 15 extracted two-rooted human maxillary premolars and 15 mandibular first molars were used. Both root canals in the premolars (N = 30) and the distal root canal in the molars (N = 15) were prepared using ProFile instruments and filled by lateral compaction using gutta-percha and AH Plus sealer. Canals were later retreated using the last ProFile used for instrumentation followed by two ProFiles of increasing size. Teeth were viewed in a μCT scanner before and after each treatment step. Defined and validated threshold levels were used to differentiate empty root canal volumes, root dentine and root filling materials from each other. CSRCS was defined as the averaged ratio between bucco-lingual and mesio-distal canal diameter (round ≤ 1, oval 1-2, long oval 2-4 and flattened ≥ 4), determined for each 1 mm over the total root length. Data were averaged between the two canals in premolars, only the distal canals were assessed in molars. Parametric and non-parametric tests were used to statistically compare the data, alpha = 0.01. Canals in premolars had a round CSRCS after preparation (1.0 ± 0.0), whereas distal counterparts in molars were oval (1.6 ± 0.5). Significantly (P < 0.01) more canal volume could be filled, and significantly less filling material remained after retreatment in premolars compared with mandibular molar distal canals. There was a high correlation between CSRCS, filled canal volume and remaining filling material. The endodontic procedures under investigation were significantly influenced by the cross-sectional root canal shape. © 2012 International Endodontic Journal. Published by Blackwell Publishing Ltd.
A multifunctional force microscope for soft matter with in situ imaging
NASA Astrophysics Data System (ADS)
Roberts, Paul; Pilkington, Georgia A.; Wang, Yumo; Frechette, Joelle
2018-04-01
We present the multifunctional force microscope (MFM), a normal and lateral force-measuring instrument with in situ imaging. In the MFM, forces are calculated from the normal and lateral deflection of a cantilever as measured via fiber optic sensors. The motion of the cantilever is controlled normally by a linear micro-translation stage and a piezoelectric actuator, while the lateral motion of the sample is controlled by another linear micro-translation stage. The micro-translation stages allow for travel distances that span 25 mm with a minimum step size of 50 nm, while the piezo has a minimum step size of 0.2 nm, but a 100 μm maximum range. Custom-designed cantilevers allow for the forces to be measured over 4 orders of magnitude (from 50 μN to 1 N). We perform probe tack, friction, and hydrodynamic drainage experiments to demonstrate the sensitivity, versatility, and measurable force range of the instrument.
NASA Astrophysics Data System (ADS)
Orlov, Timofey; Sadkov, Sergey; Panchenko, Evgeniy; Zverev, Andrey
2017-04-01
Peatlands occupy a significant share of the cryolithozone area. They are currently experiencing an intense affection by oil and gas field development, as well as by the construction of infrastructure. That poses the importance of the peatland studies, including those dealing with the forecast of peatland evolution. Earlier we conducted a similar probabilistic modelling for the areas of thermokarst development. Principle points of that were: 1. Appearance of a thermokarst depression within an area given is the random event which probability is directly proportional to the size of the area ( Δs). For small sites the probability of one thermokarst depression to appear is much greater than that for several ones, i.e. p1 = γ Δs + o (Δs) pk = o (Δs) \\quad k=2,3 ... 2. Growth of a new thermokarst depression is a random variable independent on other depressions' growth. It happens due to thermoabrasion and, hence, is directly proportional to the amount of heat in the lake and is inversely proportional to the lateral surface area of the lake depression. By using this model, we are able to get analytically two main laws of the morphological pattern for lake thermokarst plains. First, the distribution of a number of thermokarst depressions (centers) at a random plot obey the Poisson law: P(k,s) = (γ s)^k/k! e-γ s. where γ is an average number of depressions per area unit, s is a square of a trial sites. Second, lognormal distribution of diameters of thermokarst lakes is true at any time, i.e. density distribution is given by the equation: fd (x,t)=1/√{2πσ x √{t}} e-
Kinetic energy distribution of multiply charged ions in Coulomb explosion of Xe clusters.
Heidenreich, Andreas; Jortner, Joshua
2011-02-21
We report on the calculations of kinetic energy distribution (KED) functions of multiply charged, high-energy ions in Coulomb explosion (CE) of an assembly of elemental Xe(n) clusters (average size (n) = 200-2171) driven by ultra-intense, near-infrared, Gaussian laser fields (peak intensities 10(15) - 4 × 10(16) W cm(-2), pulse lengths 65-230 fs). In this cluster size and pulse parameter domain, outer ionization is incomplete∕vertical, incomplete∕nonvertical, or complete∕nonvertical, with CE occurring in the presence of nanoplasma electrons. The KEDs were obtained from double averaging of single-trajectory molecular dynamics simulation ion kinetic energies. The KEDs were doubly averaged over a log-normal cluster size distribution and over the laser intensity distribution of a spatial Gaussian beam, which constitutes either a two-dimensional (2D) or a three-dimensional (3D) profile, with the 3D profile (when the cluster beam radius is larger than the Rayleigh length) usually being experimentally realized. The general features of the doubly averaged KEDs manifest the smearing out of the structure corresponding to the distribution of ion charges, a marked increase of the KEDs at very low energies due to the contribution from the persistent nanoplasma, a distortion of the KEDs and of the average energies toward lower energy values, and the appearance of long low-intensity high-energy tails caused by the admixture of contributions from large clusters by size averaging. The doubly averaged simulation results account reasonably well (within 30%) for the experimental data for the cluster-size dependence of the CE energetics and for its dependence on the laser pulse parameters, as well as for the anisotropy in the angular distribution of the energies of the Xe(q+) ions. Possible applications of this computational study include a control of the ion kinetic energies by the choice of the laser intensity profile (2D∕3D) in the laser-cluster interaction volume.
Monfredi, Oliver; Maltseva, Larissa A.; Spurgeon, Harold A.; Boyett, Mark R.; Lakatta, Edward G.; Maltsev, Victor A.
2013-01-01
Spontaneous, submembrane local Ca2+ releases (LCRs) generated by the sarcoplasmic reticulum in sinoatrial nodal cells, the cells of the primary cardiac pacemaker, activate inward Na+/Ca2+-exchange current to accelerate the diastolic depolarization rate, and therefore to impact on cycle length. Since LCRs are generated by Ca2+ release channel (i.e. ryanodine receptor) openings, they exhibit a degree of stochastic behavior, manifested as notable cycle-to-cycle variations in the time of their occurrence. Aim The present study tested whether variation in LCR periodicity contributes to intrinsic (beat-to-beat) cycle length variability in single sinoatrial nodal cells. Methods We imaged single rabbit sinoatrial nodal cells using a 2D-camera to capture LCRs over the entire cell, and, in selected cells, simultaneously measured action potentials by perforated patch clamp. Results LCRs begin to occur on the descending part of the action potential-induced whole-cell Ca2+ transient, at about the time of the maximum diastolic potential. Shortly after the maximum diastolic potential (mean 54±7.7 ms, n = 14), the ensemble of waxing LCR activity converts the decay of the global Ca2+ transient into a rise, resulting in a late, whole-cell diastolic Ca2+ elevation, accompanied by a notable acceleration in diastolic depolarization rate. On average, cells (n = 9) generate 13.2±3.7 LCRs per cycle (mean±SEM), varying in size (7.1±4.2 µm) and duration (44.2±27.1 ms), with both size and duration being greater for later-occurring LCRs. While the timing of each LCR occurrence also varies, the LCR period (i.e. the time from the preceding Ca2+ transient peak to an LCR’s subsequent occurrence) averaged for all LCRs in a given cycle closely predicts the time of occurrence of the next action potential, i.e. the cycle length. Conclusion Intrinsic cycle length variability in single sinoatrial nodal cells is linked to beat-to-beat variations in the average period of individual LCRs each cycle. PMID:23826247
Tyutereva, Elena V; Evkaikina, Anastasiia I; Ivanova, Alexandra N; Voitsekhovskaja, Olga V
2017-09-01
The lateral mobility of integral components of thylakoid membranes, such as plastoquinone, xanthophylls, and pigment-protein complexes, is critical for the maintenance of efficient light harvesting, high rates of linear electron transport, and successful repair of damaged photosystem II (PSII). The packaging of the photosynthetic pigment-protein complexes in the membrane depends on their size and stereometric parameters which in turn depend on the composition of the complexes. Chlorophyll b (Chlb) is an important regulator of antenna size and composition. In this study, the lateral mobility (the mobile fraction size) of pigment-protein complexes and lipids in grana membranes was analyzed in chlorina mutants of Arabidopsis and barley lacking Chlb. In the Arabidopsis ch1-3 mutant, diffusion of membrane lipids decreased as compared to wild-type plants, but the diffusion of photosynthetic complexes was not affected. In the barley chlorina f2 3613 mutant, the diffusion of pigment-protein complexes significantly decreased, while the diffusion of lipids increased, as compared to wild-type plants. We propose that the size of the mobile fractions of pigment-protein complexes in grana membranes in vivo is higher than reported previously. The data are discussed in the context of the protein composition of antennae, characteristics of the plastoquinone pool, and production of reactive oxygen species in leaves of chlorina mutants.
NASA Astrophysics Data System (ADS)
Irvine, J. R.; O'Neill, M.; Godbout, L.; Schnute, J.
2013-08-01
Altering release sizes and timings of coho salmon smolts from hatcheries in the Strait of Georgia will not reverse the precipitous survival declines of the past three decades. We modeled the effects on survival of ocean entry year, mean smolt size (weight), and release day. Ocean entry year was by far the most important. During 1979-2006, smolt to adult survivals declined similarly for hatchery and wild coho salmon, although wild salmon consistently survived at higher rates. Best models differed among hatcheries, implying location-specific differences in the optimal size and timing of release. At four of five hatcheries, heavier smolts survived significantly better than lighter smolts. At one hatchery, a significant interaction between ocean entry year and smolt weight reflected an increased positive effect of weight later in the time series. At two Vancouver Island hatcheries, early release groups appeared to survive better than later releases in early years, while later release groups survived best in recent years. We recommend: (1) hatchery managers release coho salmon smolts throughout the outmigration period of higher surviving wild coho salmon smolts and (2) an experimental approach using hatcheries to evaluate density-dependent effects on coho salmon growth and survival.
Spatial variability of shelf sediments in the STRATAFORM natural laboratory, Northern California
Goff, J.A.; Wheatcroft, R.A.; Lee, H.; Drake, D.E.; Swift, D.J.P.; Fan, S.
2002-01-01
The "Correlation Length Experiment", an intensive box coring effort on the Eel River shelf (Northern California) in the summer of 1997, endeavored to characterize the lateral variability of near-surface shelf sediments over scales of meters to kilometers. Coring focused on two sites, K60 and S60, separated by ??? 15 km along the 60 m isobath. The sites are near the sand-to-mud transition, although K60 is sandier owing to its proximity to the Eel River mouth. Nearly 140 cores were collected on dip and strike lines with core intervals from < 10m to 1 km. Measurements on each core included bulk density computed from gamma-ray attenuation, porosity converted from resistivity measurements, and surficial grain size. Grain size was also measured over the full depth range within a select subset of cores. X-radiograph images were also examined. Semi-variograms were computed for strike, dip, and down-hole directions at each site. The sand-to-mud transition exerts a strong influence on all measurements: on average, bulk density increases and porosity decreases with regional increases in mean grain size. Analysis of bulk density measurements indicates very strong contrasts in the sediment variability at K60 and S60. No coherent bedding is seen at K60; in the strike direction, horizontal variability is "white" (fully uncorrelated) from the smallest scales examined (a few meters) to the largest (8 km), with a variance equal to that seen within the cores. In contrast, coherent bedding exists at S60 related to the preservation of the 1995 flood deposit. A correlatable structure is found in the strike direction with a decorrelation distance of ??? 800 m, and can be related to long-wavelength undulations in the topography and/or thickness of the flood layer or overburden. We hypothesize that the high degree of bulk density variability at K60 is a result of more intense physical reworking of the seabed in the sandier environment. Without significant averaging, the resistivity-based porosity measurements are only marginally correlated to gamma-ray-bulk density measurements, and are largely independent of mean grain size. Furthermore, porosity displays a high degree of incoherent variability at both sites. Porosity, with a much smaller sample volume than bulk density, may therefore resolve small-scale biogenic variability which is filtered out in the bulk density measurement. ?? 2002 Elsevier Science Ltd. All rights reserved.
Using Flexible Busing to Meet Average Class Size Targets
ERIC Educational Resources Information Center
Felt, Andrew J.; Koelemay, Ryan; Richter, Alexander
2008-01-01
This article describes a method of flexible redistricting for K-12 public school districts that allows students from the same geographical region to be bused to different schools, with the goal of meeting average class size (ACS) target ranges. Results of a case study on a geographically large school district comparing this method to a traditional…
A Response to Holster and Lake Regarding Guessing and the Rasch Model
ERIC Educational Resources Information Center
Stewart, Jeffrey; McLean, Stuart; Kramer, Brandon
2017-01-01
Stewart questioned vocabulary size estimation methods proposed by Beglar and Nation for the Vocabulary Size Test, further arguing Rasch mean square (MSQ) fit statistics cannot determine the proportion of random guesses contained in the average learner's raw score, because the average value will be near 1 by design. He illustrated this by…
Gingival zenith positions and levels of the maxillary anterior dentition.
Chu, Stephen J; Tan, Jocelyn H-P; Stappert, Christian F J; Tarnow, Dennis P
2009-01-01
The location of the gingival zenith in a medial-lateral position relative to the vertical tooth axis of the maxillary anterior teeth remains to be clearly defined. In addition, the apex of the free gingival margin of the lateral incisor teeth relative to the gingival zeniths of the adjacent proximal teeth remains undetermined. Therefore, this investigation evaluated two clinical parameters: (1) the gingival zenith position (GZP) from the vertical bisected midline (VBM) along the long axis of each individual maxillary anterior tooth; and (2) the gingival zenith level (GZL) of the lateral incisors in an apical-coronal direction relative to the gingival line joining the tangents of the GZP of the adjacent central incisor and canine teeth under healthy conditions. A total of 240 sites in 20 healthy patients (13 females, 7 males) with an average age of 27.7 years were evaluated. The inclusion patient criteria were absence of periodontal disease, gingival recession, or gingival hypertrophy as well as teeth without loss of interdental papillae, spacing, crowding, existing restorations, and incisal attrition. GZP dimensions were measured with calibrated digital calipers for each individual tooth and within each tooth group in a medial-lateral direction from the VBM. GZLs were measured in an apical-coronal direction from a tangent line drawn on the diagnostic casts from the GZPs of the adjacent teeth. This study demonstrated that all central incisors displayed a distal GZP from the VBM, with a mean average of 1 mm. Lateral incisors showed a deviation of the gingival zenith by a mean of 0.4 mm. In 97.5% of the canine population, the GZP was centralized along the long axis of the canine. The mean distance of the contour of the gingival margin in an apical-coronal direction of the lateral incisors (GZL) relative to gingival line joining the tangent of the adjacent central and canine GZPs was approximately 1 mm. This investigation revealed a GZP mean value of 1 mm distal from the VBM for the central incisor tooth group. The lateral incisors showed a mean average of 0.4 mm. The canine tooth group demonstrated almost no deviations of the GZP from the VBM. The GZL of the lateral incisors relative to the adjacent central incisor and canine teeth were more coronal by approximately 1 mm. These data could be used as reference points during esthetic anterior oral rehabilitation. The information presented in this article can be clinically applied to reestablish the proper intratooth GZPs of the maxillary anterior teeth during periodontal crown lengthening or root coverage procedures. In addition, the intra-arch gingival level of the lateral incisor gingival zenith relative to the adjacent central and canine teeth can be appropriately established.
Pang, Chong-guang; Yu, Wei; Yang, Yang
2010-03-01
In July of 2008, under the natural condition of sea water, the Laser in-situ scattering and transmissometry (LISST-100X Type C) was used to measure grain size distribution spectrum and volume concentration of total suspended matter in the sea water, including flocs at different layers of 24 sampling stations at Changjiang Estuary and its adjacent sea. The characteristics and its forming mechanism on grain size distribution of total suspended matter were analyzed based on the observation data of LISST-100X Type C, and combining with the temperature, salinity and turbidity of sea water, simultaneously observed by Alec AAQ1183. The observation data showed that the average median grain size of total suspended matter was about 4.69 phi in the whole measured sea area, and the characteristics of grain size distribution was relatively poor sorted, wide kurtosis, and basically symmetrical. The conclusion could be drawn that vertically average volume concentration decreased with the distance from the coastline, while median grain size had an increase trend with the distance, for example, at 31.0 degrees N section, the depth-average median grain size had been increased from 11 microm up to 60 microm. With the increasing of distance from the coast, the concentration of fine suspended sediment reduced distinctly, nevertheless some relatively big organic matter or big flocs appeared in quantity, so its grain size would rise. The observation data indicated that the effective density was ranged from 246 kg/m3 to 1334 kg/m, with average was 613 kg/m3. When the concentration of total suspended matter was relatively high, median grain size of total suspended matter increased with the water depth, while effective density decreased with the depth, because of the faster settling velocity and less effective density of large flocs that of small flocs. As for station 37 and 44, their correlation coefficients between effective density and median grain size were larger than 0.9.
Tolstikhin, Valery; Saeidi, Shayan; Dolgaleva, Ksenia
2018-05-01
We report on the design optimization and tolerance analysis of a multistep lateral-taper spot-size converter based on indium phosphide (InP), performed using the Monte Carlo method. Being a natural fit to (and a key building block of) the regrowth-free taper-assisted vertical integration platform, such a spot-size converter enables efficient and displacement-tolerant fiber coupling to InP-based photonic integrated circuits at a wavelength of 1.31 μm. An exemplary four-step lateral-taper design featuring 0.35 dB coupling loss at optimal alignment of a standard single-mode fiber; ≥7 μm 1 dB displacement tolerance in any direction in a facet plane; and great stability against manufacturing variances is demonstrated.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Parts 85, 86, and 600 DEPARTMENT OF TRANSPORTATION National Highway Traffic Safety Administration 49 CFR Parts 523, 531, 533, 536, and 537 [EPA-HQ-OAR-2010-0799; FRL-9706-5; NHTSA-2010-0131] RIN 2060-AQ54; RIN 2127-AK79 2017 and Later Model Year Light-Duty Vehicle Greenhouse Gas Emissions and Corporate...
Winfield, Kari A.
2003-01-01
The subsurface at the Idaho National Engineering and Environmental Laboratory (INEEL) is complex, comprised primarily of thick, fractured basalt flows interbedded with thinner sedimentary intervals. The unsaturated zone can be as thick as 200 m in the southwestern part of the INEEL. The Vadose Zone Research Park (VZRP), located approximately 10 km southwest of the Idaho Nuclear Technology and Engineering Center (INTEC), was established in 2001 to study the subsurface of a relatively undisturbed part of the INEEL. Waste percolation ponds for the INTEC were relocated to the VZRP due to concerns that perched water within the vadose zone under the original infiltration ponds (located immediately south of the INTEC) could contribute to migration of contaminants to the Snake River Plain aquifer. Knowledge of the spatial distribution of texture and hydraulic properties is important for developing a better understanding of subsurface flow processes within the interbeds, for example, by identifying low permeability layers that could lead to the formation of perched ground-water zones. Because particle-size distributions are easier to measure than hydraulic properties, particle size serves as an analog for determining how the unsaturated hydraulic properties vary both vertically within particular interbeds and laterally within the VZRP. As part of the characterization program for the subsurface at the VZRP, unsaturated and saturated hydraulic properties were measured on 10 core samples from six boreholes. Bulk properties, including particle size, bulk density, particle density, and specific surface area, were determined on material from the same depth intervals as the core samples, with an additional 66 particle- size distributions measured on bulk samples from the same boreholes. From lithologic logs of the 32 boreholes at the VZRP, three relatively thick interbeds (in places up to 10 m thick) were identified at depths of 35, 45, and 55 m below land surface. The 35-m interbed extends laterally over a distance of at least 900 m from the Big Lost River to the new percolation pond area of the VZRP. Most wells within the VZRP were drilled to depths less than 50 m, making it difficult to infer the lateral extent of the 45-m and 55-m interbeds. The 35-m interbed is uniform in texture both vertically and laterally; the 45-m interbed coarsens upward; and the 55-m interbed contains alternating coarse and fine layers. Seventy-one out of 90 samples were silt loams and 9 out of 90 samples were classified as either sandy loams, loamy sands, or sands. The coarsest samples were located within the 45-m and 55-m interbeds of borehole ICPP-SCI-V-215, located near the southeast corner of the new percolation pond area. At the tops of some interbeds, baked-zone intervals were identified by their oxidized color (yellowish red to red) compared to the color of the underlying non-baked material (pale yellow to brown). The average geometric mean particle diameter of baked-zone intervals was only slightly coarser, in some cases, than the underlying non-baked sediment. This is likely due to both depositional differences between the top and bottom of the interbeds and the presence of small basalt clasts in the sediment. Core sample hydraulic properties from baked zones within the different interbeds did not show effects from alteration caused during basalt deposition, but differed mainly by texture. Saturated hydraulic conductivities (Ksat) for the 10 core samples ranged from 10-7 to 10-4 cm/s. Low permeability layers, with Ksat values less than 10-7 cm/s, within the 35-m and 45-m interbeds may cause perched ground-water zones to form beneath the new percolation pond area, leading to the possible lateral movement of water away from the VZRP.
Vogt, L; Brettmann, K; Pfeifer, K; Banzer, W
2003-04-08
This study examined the angular gait kinematics of the trunk and the pelvis in the frontal plane and their amount of side-to-side asymmetry in patients after total hip replacement arthroplasty. The angular gait kinematics of 12 male hip arthroplasty patients (53-70 years) were compared to ten age-matched and ten young (24-35 years) male control subjects. Average step times and medio-lateral oscillation amplitudes of the pelvic and thoracic recordings were calculated for each step. Between successive steps the asymmetry ratio was computed and the mean angle around which the side-to-side oscillations occurred was compared to the angle in a symmetrical standing trial. ANOVA indicated no significant side differences in relative step cycle durations. Patients and senior controls had significantly (p<0.01) less pelvis side-to-side displacements than the younger controls. No significant between-group differences could be detected for the average asymmetry ratio. However, during walking the patients showed a significantly (p<0.01) increased lateral thorax and pelvis deviation. Hip replacement patients' thoracic and pelvic position is characterized by a lateral shift throughout the gait cycle, while left and right symmetry of angular movements amplitudes remain at about the same value of unimpaired subjects.
Cleaning lateral morphological features of the root canal: the role of streaming and cavitation.
Robinson, J P; Macedo, R G; Verhaagen, B; Versluis, M; Cooper, P R; van der Sluis, L W M; Walmsley, A D
2018-01-01
To investigate the effects of ultrasonic activation file type, lateral canal location and irrigant on the removal of a biofilm-mimicking hydrogel from a fabricated lateral canal. Additionally, the amount of cavitation and streaming was quantified for these parameters. An intracanal sonochemical dosimetry method was used to quantify the cavitation generated by an IrriSafe 25 mm length, size 25 file inside a root canal model filled with filtered degassed/saturated water or three different concentrations of NaOCl. Removal of a hydrogel, demonstrated previously to be an appropriate biofilm mimic, was recorded to measure the lateral canal cleaning rate from two different instruments (IrriSafe 25 mm length, size 25 and K 21 mm length, size 15) activated with a P5 Suprasson (Satelec) at power P8.5 in degassed/saturated water or NaOCl. Removal rates were compared for significant differences using nonparametric Kruskal-Wallis and/or Mann-Whitney U-tests. Streaming was measured using high-speed particle imaging velocimetry at 250 kfps, analysing both the oscillatory and steady flow inside the lateral canals. There was no significant difference in amount of cavitation between tap water and oversaturated water (P = 0.538), although more cavitation was observed than in degassed water. The highest cavitation signal was generated with NaOCl solutions (1.0%, 4.5%, 9.0%) (P < 0.007) and increased with concentration (P < 0.014). The IrriSafe file outperformed significantly the K-file in removing hydrogel (P < 0.05). Up to 64% of the total hydrogel volume was removed after 20 s. The IrriSafe file typically outperformed the K-file in generating streaming. The oscillatory velocities were higher inside the lateral canal 3 mm compared to 6 mm from WL and were higher for NaOCl than for saturated water, which in turn was higher than for degassed water. Measurements of cavitation and acoustic streaming have provided insight into their contribution to cleaning. Significant differences in cleaning, cavitation and streaming were found depending on the file type and size, lateral canal location and irrigant used. In general, the IrriSafe file outperformed the K-file, and NaOCl performed better than the other irrigants tested. The cavitation and streaming measurements revealed that both contributed to hydrogel removal and both play a significant role in root canal cleaning. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Ruch, David S; Watters, Tyler Steven; Wartinbee, Daniel A; Richard, Marc J; Leversedge, Fraser J; Mithani, Suhail K
2014-08-01
To describe pertinent anatomic findings during repair of chronic, partial distal biceps tendon tears and to compare the complications of surgery with a similar cohort of acute, complete tears. Group 1 included 14 patients (15 elbows) with partial tears managed operatively an average of 10 months from onset of injury or symptoms. Group 2 included a matched cohort of 16 patients (17 elbows) treated for complete, acute tears an average of 19 days from injury. A retrospective review of all 30 patients focused on demographic data, intraoperative findings, and postoperative complications. A single, anterior incision was used in all cases with multiple suture anchors or a bicortical toggling button for fixation of the repair. We evaluated 27 men and 3 women with an average age of 55 years (group 1) and 48 years (group 2). Intratendinous ganglion formation at the site of rupture of the degenerative tendon was observed in 5 cases of partial tears and none of the complete tears. Partial tears involved the lateral aspect or short head of the biceps tendon insertion in all cases. Postoperative complications included lateral antebrachial cutaneous nerve neuritis in 8 group 1 patients and 6 group 2 patients and transient posterior interosseus nerve palsy in 3 group 1 patients. Partial distal biceps tendon ruptures showed a consistent pattern of pathology involving disruption of the lateral side of the tendon insertion involving the small head of the biceps. Degenerative intratendinous ganglion formation was present in one third of cases. Repair of chronic, partial distal biceps tendon injuries may have a higher incidence of posterior interosseous and lateral antebrachial cutaneous nerve palsies. Therapeutic III. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Taschieri, S; Weinstein, T; Rosano, G; Del Fabbro, M
2012-05-01
The purpose of this study was to investigate the relationship between the root apex of the upper incisors and neighbouring anatomical structures as well as the morphology of the root-end foramen after apicoectomy. Fifty-seven patients requiring endodontic surgical treatment for a maxillary anterior root were enrolled. A preoperative diagnostic computed tomography (CT) scan was analysed to determine: the distance between the anterior wall of the nasopalatine duct and the central (CI-ND) incisor root 4mm from the apex; and the distance between the floor of the nasal cavity and the tip of either the central (CI-NF) or the lateral (LI-NF) incisor root. After apicoectomy, root-end foramen endoscopic pictures were taken in order to characterize their morphology. Fifty-nine central and 26 lateral incisors were evaluated. The average CI-ND was 4.71 ± 1.26 (SD) mm. The average CI-NF was 10.62 ± 2.25 mm. The average LI-NF was 13.05 ± 2.43 mm. The foramen shape after apicoectomy was ovoid to circular in about 90% of cases in both central and lateral incisors. A sound knowledge of the anatomical relationships at the surgical site is essential for the clinician to perform a safe endodontic surgical procedure. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Average features of the muon component of EAS or = 10(17) eV
NASA Technical Reports Server (NTRS)
Blake, P. R.; Luksys, M.; Nash, W. F.; Sephton, A. J.
1985-01-01
Three 10 sq m liquid scintillators were situated at approximately 0 m, 150 m and 250 m from the center of the Haverah Park array. The detectors were shielded by lead/barytes giving muon detection thresholds of 317 MeV, 431 MeV and 488 MeV respectively. During part of the operational period the 431 MeV threshold was lowered to 313 MeV for comparison purposes. For risetime measurement fast phototubes were used and the 10% to 70% amplitude time interval was parameterized by T sub 70. A muon lateral density distribution of the form rho mu (R theta) = krho(500)0.94 1/R(1 + R/490)-eta has been fitted to the data for 120 m R 600 m and 0.27 (500) 2.55. The shower size parameter (500) is the water Cerenkov response at 500 m from the core of the extensive air showers (EAS) and is relatable to the primary energy. The results show general consistency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulze, C. S.; Prohl, C.; Füllert, V.
2016-04-04
The atomic structure and stoichiometry of InAs/InGaAs quantum-dot-in-a-well structures grown on exactly oriented GaP/Si(001) are revealed by cross-sectional scanning tunneling microscopy. An averaged lateral size of 20 nm, heights up to 8 nm, and an In concentration of up to 100% are determined, being quite similar compared with the well-known quantum dots grown on GaAs substrates. Photoluminescence spectra taken from nanostructures of side-by-side grown samples on GaP/Si(001) and GaAs(001) show slightly blue shifted ground-state emission wavelength for growth on GaP/Si(001) with an even higher peak intensity compared with those on GaAs(001). This demonstrates the high potential of GaP/Si(001) templates for integration ofmore » III-V optoelectronic components into silicon-based technology.« less
Carbon Nanostructure of Kraft Lignin Thermally Treated at 500 to 1000 °C.
Zhang, Xuefeng; Yan, Qiangu; Leng, Weiqi; Li, Jinghao; Zhang, Jilei; Cai, Zhiyong; Hassan, El Barbary
2017-08-21
Kraft lignin (KL) was thermally treated at 500 to 1000 °C in an inert atmosphere. Carbon nanostructure parameters of thermally treated KL in terms of amorphous carbon fraction, aromaticity, and carbon nanocrystallites lateral size ( L a ), thickness ( L c ), and interlayer space ( d 002 ) were analyzed quantitatively using X-ray diffraction, Raman spectroscopy, and high-resolution transmission electron microscopy. Experimental results indicated that increasing temperature reduced amorphous carbon but increased aromaticity in thermally treated KL materials. The L c value of thermally treated KL materials averaged 0.85 nm and did not change with temperature. The d 002 value decreased from 3.56 Å at 500 °C to 3.49 Å at 1000 °C. The L a value increased from 0.7 to 1.4 nm as temperature increased from 500 to 1000 °C. A nanostructure model was proposed to describe thermally treated KL under 1000 °C. The thermal stability of heat treated KL increased with temperature rising from 500 to 800 °C.
Choi, Dong-hak; Hiro-Oka, Hideaki; Shimizu, Kimiya; Ohbayashi, Kohji
2012-01-01
An ultrafast frequency domain optical coherence tomography system was developed at A-scan rates between 2.5 and 10 MHz, a B-scan rate of 4 or 8 kHz, and volume-rates between 12 and 41 volumes/second. In the case of the worst duty ratio of 10%, the averaged A-scan rate was 1 MHz. Two optical demultiplexers at a center wavelength of 1310 nm were used for linear-k spectral dispersion and simultaneous differential signal detection at 320 wavelengths. The depth-range, sensitivity, sensitivity roll-off by 6 dB, and axial resolution were 4 mm, 97 dB, 6 mm, and 23 μm, respectively. Using FPGAs for FFT and a GPU for volume rendering, a real-time 4D display was demonstrated at a rate up to 41 volumes/second for an image size of 256 (axial) × 128 × 128 (lateral) voxels. PMID:23243560
The MXB1916-053/4U1915-05: Burst properties and constraints on a 50 minute binary secondary
NASA Technical Reports Server (NTRS)
Swank, J. H.; Taam, R. E.; White, N. E.
1983-01-01
Results are presented from OSO-8 and HEAO-1 A2 observations of 34 bursts from the X-ray burster MXB1916-053/4U1915-05 recently discovered to show a 50 minute binary period. While 11 burst previously reported all had similar light curves, 22 observed two years later show a factor of 3 range of peak fluxes and decay times between 3 and 20 s. Recurrence times between successive bursts vary between 3 and 6 hours. A ratio of steady flux to average burst flux of equiv 120 is developed. A burst observed with the HEAO-1 A2 experiment showed an initial temperature rise to a peak black body temperature of equiv 3 keV followed by the cooling typical of type I bursts. The burst was unusual in that the apparent projected size of a blackbody source increased by a factor of 3 during the cooling phase.
Fixed dynamometry is more sensitive than vital capacity or ALS rating scale.
Andres, Patricia L; Allred, Margaret Peggy; Stephens, Helen E; Proffitt Bunnell, Mary; Siener, Catherine; Macklin, Eric A; Haines, Travis; English, Robert A; Fetterman, Katherine A; Kasarskis, Edward J; Florence, Julaine; Simmons, Zachary; Cudkowicz, Merit E
2017-10-01
Improved outcome measures are essential to efficiently screen the growing number of potential amyotrophic lateral sclerosis (ALS) therapies. This longitudinal study of 100 (70 male) participants with ALS compared Accurate Test of Limb Isometric Strength (ATLIS), using a fixed, wireless load cell, with ALS Functional Rating Scale-Revised (ALSFRS-R) and vital capacity (VC). Participants enrolled at 5 U.S. sites. Data were analyzed from 66 participants with complete ATLIS, ALSFRS-R, and VC data over at least 3 visits. Change in ATLIS was less variable both within- and among-person than change in ALSFRS-R or VC. Additionally, participants who had normal ALSFRS-R arm and leg function averaged 12 to 32% below expected strength values measured by ATLIS. ATLIS was more sensitive to change than ALSFRS-R or VC and could decrease sample size requirements by approximately one-third. The ability of ATLIS to detect prefunctional change has potential value in early trials. Muscle Nerve 56: 710-715, 2017. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shete, Meera; Kumar, Prashant; Bachman, Jonathan E.
High aspect-ratio nanosheets of metal-organic frameworks (MOFs) hold promise for use as selective flakes in gas separation membranes. However, simple and scalable methods for the synthesis of MOF nanosheets have thus far remained elusive. Here, we describe the direct synthesis of Cu(BDC) (BDC2-= 1,4-benzenedicarboxylate) nanosheets with an average lateral size of 2.5 mu m and a thickness of 25 nm from a well-mixed solution. Characterization of the nanosheets by powder and thin film X-ray diffraction, electron microscopy, and electron diffraction reveals pronounced structural disorder that may affect their pore structure. Incorporation of the Cu (BDC) nanosheets into a Matrimid polymermore » matrix results in mixed matrix membranes (MMMs) that exhibit a 70% increase in the CO2/CH4 selectivity compared with that of Matrimid. Analysis of new and previously reported permeation data for Cu(BDC) MMMs using a mathematical model for selective flake composites indicates that further performance improvements could be achieved with the selection of different polymers for use in the continuous phase.« less
NASA Astrophysics Data System (ADS)
Ge, Xiaochen; Minkov, Momchil; Fan, Shanhui; Li, Xiuling; Zhou, Weidong
2018-04-01
We report here design and experimental demonstration of heterostructure photonic crystal cavities resonating near the Γ point with simultaneous strong lateral confinement and highly directional vertical radiation patterns. The lateral confinement is provided by a mode gap originating from a gradual modulation of the hole radii. High quality factor resonance is realized with a low index contrast between silicon nitride and quartz. The near surface-normal directional emission is preserved when the size of the core region is scaled down. The influence of the cavity size parameters on the resonant modes is also investigated theoretically and experimentally.
Asymmetry in the epithalamus of vertebrates
L. CONCHA, MIGUEL; W. WILSON, STEPHEN
2001-01-01
The epithalamus is a major subdivision of the diencephalon constituted by the habenular nuclei and pineal complex. Structural asymmetries in this region are widespread amongst vertebrates and involve differences in size, neuronal organisation, neurochemistry and connectivity. In species that possess a photoreceptive parapineal organ, this structure projects asymmetrically to the left habenula, and in teleosts it is also situated on the left side of the brain. Asymmetries in size between the left and right sides of the habenula are often associated with asymmetries in neuronal organisation, although these two types of asymmetry follow different evolutionary courses. While the former is more conspicuous in fishes (with the exception of teleosts), asymmetries in neuronal organisation are more robust in amphibia and reptiles. Connectivity of the parapineal organ with the left habenula is not always coupled with asymmetries in habenular size and/or neuronal organisation suggesting that, at least in some species, assignment of parapineal and habenular asymmetries may be independent events. The evolutionary origins of epithalamic structures are uncertain but asymmetry in this region is likely to have existed at the origin of the vertebrate, perhaps even the chordate, lineage. In at least some extant vertebrate species, epithalamic asymmetries are established early in development, suggesting a genetic regulation of asymmetry. In some cases, epigenetic factors such as hormones also influence the development of sexually dimorphic habenular asymmetries. Although the genetic and developmental mechanisms by which neuroanatomical asymmetries are established remain obscure, some clues regarding the mechanisms underlying laterality decisions have recently come from studies in zebrafish. The Nodal signalling pathway regulates laterality by biasing an otherwise stochastic laterality decision to the left side of the epithalamus. This genetic mechanism ensures a consistency of epithalamic laterality within the population. Between species, the laterality of asymmetry is variable and a clear evolutionary picture is missing. We propose that epithalamic structural asymmetries per se and not the laterality of these asymmetries are important for the behaviour of individuals within a species. A consistency of the laterality within a population may play a role in social behaviours between individuals of the species. PMID:11523830
40 CFR 600.504-78 - Section numbering, construction.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's...
40 CFR 600.503-78 - Abbreviations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy § 600.503-78 Abbreviations. The...
40 CFR 600.505-78 - Recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy § 600.505-78 Recordkeeping. The...
Sharp, R.V.
1989-01-01
The M6.2 Elmore Desert Ranch earthquake of 24 November 1987 was associated spatially and probably temporally with left-lateral surface rupture on many northeast-trending faults in and near the Superstition Hills in western Imperial Valley. Three curving discontinuous principal zones of rupture among these breaks extended northeastward from near the Superstition Hills fault zone as far as 9km; the maximum observed surface slip, 12.5cm, was on the northern of the three, the Elmore Ranch fault, at a point near the epicenter. Twelve hours after the Elmore Ranch earthquake, the M6.6 Superstition Hills earthquake occurred near the northwest end of the right-lateral Superstition Hills fault zone. We measured displacements over 339 days at as many as 296 sites along the Superstition Hills fault zone, and repeated measurements at 49 sites provided sufficient data to fit with a simple power law. The overall distributions of right-lateral displacement at 1 day and the estimated final slip are nearly symmetrical about the midpoint of the surface rupture. The average estimated final right-lateral slip for the Superstition Hills fault zone is ~54cm. The average left-lateral slip for the conjugate faults trending northeastward is ~23cm. The southernmost ruptured member of the Superstition Hills fault zone, newly named the Wienert fault, extends the known length of the zone by about 4km. -from Authors
Correlation between large-scale atmospheric fields and the olive pollen season in Central Italy
NASA Astrophysics Data System (ADS)
Avolio, E.; Pasqualoni, L.; Federico, S.; Fornaciari, M.; Bonofiglio, T.; Orlandi, F.; Bellecci, C.; Romano, B.
2008-11-01
Olives are one of the largest crops in the Mediterranean and in central and southern Italy. This work investigates the correlation of the Olea europaea L. pollen season in Perugia, the capital city of the region of Umbria in central Italy, with atmospheric parameters. The aim of the study is twofold. First, we study the correlation between the pollen season and the surface air temperature of the spring and late spring in Perugia. Second, the correlation between the pollen season and large-scale atmospheric patterns is investigated. The average surface temperature in the spring and late spring has a clear impact on the pollen season in Perugia. Years with higher average temperatures have an earlier onset of the pollen season. In particular, a 1°C higher (lower) average surface temperature corresponds to an earlier (later) start of the pollen season of about 1 week. The correlation between the pollen season and large-scale atmospheric patterns of sea level pressure and 500-hPa geopotential height shows that the cyclonic activity in the Mediterranean is unequivocally tied to the pollen season in Perugia. A larger than average cyclonic activity in the Mediterranean Basin corresponds to a later than average pollen season. Larger than average cyclonic activity in Northern Europe and Siberia corresponds to an earlier than average pollen season. A possible explanation of this correlation, that needs further investigation to be proven, is given. These results can have a practical application by using the seasonal forecast of atmospheric general circulation models.
Evaluation of type II thyroplasty on phonatory physiology in an excised canine larynx model
Devine, Erin E.; Hoffman, Matthew R.; McCulloch, Timothy M.; Jiang, Jack J.
2016-01-01
Objective Type II thyroplasty is an alternative treatment for spasmodic dysphonia, addressing hyperadduction by incising and lateralizing the thyroid cartilage. We quantified the effect of lateralization width on phonatory physiology using excised canine larynges. Methods Normal closure, hyperadduction, and type II thyroplasty (lateralized up to 5mm at 1mm increments with hyperadducted arytenoids) were simulated in excised larynges (N=7). Aerodynamic, acoustic, and videokymographic data were recorded at three subglottal pressures relative to phonation threshold pressure (PTP). One-way repeated measures ANOVA assessed effect of condition on aerodynamic parameters. Random intercepts linear mixed effects models assessed effects of condition and subglottal pressure on acoustic and videokymographic parameters. Results PTP differed across conditions (p<0.001). Condition affected percent shimmer (p<0.005) but not percent jitter. Both pressure (p<0.03) and condition (p<0.001) affected fundamental frequency. Pressure affected vibratory amplitude (p<0.05) and intra-fold phase difference (p<0.05). Condition affected phase difference between the vocal folds (p<0.001). Conclusions Hyperadduction increased PTP and worsened perturbation compared to normal, with near normal physiology restored with 1mm lateralization. Further lateralization deteriorated voice quality and increased PTP. Acoustic and videokymographic results indicate that normal physiologic relationships between subglottal pressure and vibration are preserved at optimal lateralization width, but then degrade with further lateralization. The 1mm optimal width observed here is due to the small canine larynx size. Future human trials would likely demonstrate a greater optimal width, with patient-specific value potentially determined based on larynx size and symptom severity. PMID:27223665
Electrophoretic deposition of fluorescent Cu and Au sheets for light-emitting diodes
NASA Astrophysics Data System (ADS)
Liu, Jiale; Wu, Zhennan; Li, Tingting; Zhou, Ding; Zhang, Kai; Sheng, Yu; Cui, Jianli; Zhang, Hao; Yang, Bai
2015-12-01
Electrophoretic deposition (EPD) is a conventional method for fabricating film materials from nanometer-sized building blocks, and exhibits the advantages of low-cost, high-efficiency, wide-range thickness adjustment, and uniform deposition. Inspired by the interest in the application of two-dimensional (2D) nanomaterials, the EPD technique has been recently extended to building blocks with 2D features. However, the studies are mainly focused on simplex building blocks. The utilization of multiplex building blocks is rarely reported. In this work, we demonstrate a controlled EPD of Cu and Au sheets, which are 2D assemblies of luminescent Cu and Au nanoclusters. Systematic investigations reveal that both the deposition efficiency and the thickness are determined by the lateral size of the sheets. For Cu sheets with a large lateral size, a high ζ-potential and strong face-to-face van der Waals interactions facilitate the deposition with high efficiency. However, for Au sheets, the small lateral size and ζ-potential limit the formation of a thick film. To solve this problem, the deposition dynamics are controlled by increasing the concentration of the Au sheets and adding acetone. This understanding permits the fabrication of a binary EPD film by the stepwise deposition of Cu and Au sheets, thus producing a luminescent film with both Cu green emission and Au red emission. A white light-emitting diode prototype with color coordinates (x, y) = (0.31, 0.36) is fabricated by employing the EPD film as a color conversion layer on a 365 nm GaN clip and further tuning the amount of deposited Cu and Au sheets.Electrophoretic deposition (EPD) is a conventional method for fabricating film materials from nanometer-sized building blocks, and exhibits the advantages of low-cost, high-efficiency, wide-range thickness adjustment, and uniform deposition. Inspired by the interest in the application of two-dimensional (2D) nanomaterials, the EPD technique has been recently extended to building blocks with 2D features. However, the studies are mainly focused on simplex building blocks. The utilization of multiplex building blocks is rarely reported. In this work, we demonstrate a controlled EPD of Cu and Au sheets, which are 2D assemblies of luminescent Cu and Au nanoclusters. Systematic investigations reveal that both the deposition efficiency and the thickness are determined by the lateral size of the sheets. For Cu sheets with a large lateral size, a high ζ-potential and strong face-to-face van der Waals interactions facilitate the deposition with high efficiency. However, for Au sheets, the small lateral size and ζ-potential limit the formation of a thick film. To solve this problem, the deposition dynamics are controlled by increasing the concentration of the Au sheets and adding acetone. This understanding permits the fabrication of a binary EPD film by the stepwise deposition of Cu and Au sheets, thus producing a luminescent film with both Cu green emission and Au red emission. A white light-emitting diode prototype with color coordinates (x, y) = (0.31, 0.36) is fabricated by employing the EPD film as a color conversion layer on a 365 nm GaN clip and further tuning the amount of deposited Cu and Au sheets. Electronic supplementary information (ESI) available: Additional experimental information, and SEM images of Cu EPD films. See DOI: 10.1039/c5nr06599b
Size Matters: FTIR Spectral Analysis of Apollo Regolith Samples Exhibits Grain Size Dependence.
NASA Astrophysics Data System (ADS)
Martin, Dayl; Joy, Katherine; Pernet-Fisher, John; Wogelius, Roy; Morlok, Andreas; Hiesinger, Harald
2017-04-01
The Mercury Thermal Infrared Spectrometer (MERTIS) on the upcoming BepiColombo mission is designed to analyse the surface of Mercury in thermal infrared wavelengths (7-14 μm) to investigate the physical properties of the surface materials [1]. Laboratory analyses of analogue materials are useful for investigating how various sample properties alter the resulting infrared spectrum. Laboratory FTIR analysis of Apollo fine (<1mm) soil samples 14259,672, 15401,147, and 67481,96 have provided an insight into how grain size, composition, maturity (i.e., exposure to space weathering processes), and proportion of glassy material affect their average infrared spectra. Each of these samples was analysed as a bulk sample and five size fractions: <25, 25-63, 63-125, 125-250, and <250 μm. Sample 14259,672 is a highly mature highlands regolith with a large proportion of agglutinates [2]. The high agglutinate content (>60%) causes a 'flattening' of the spectrum, with reduced reflectance in the Reststrahlen Band region (RB) as much as 30% in comparison to samples that are dominated by a high proportion of crystalline material. Apollo 15401,147 is an immature regolith with a high proportion of volcanic glass pyroclastic beads [2]. The high mafic mineral content results in a systematic shift in the Christiansen Feature (CF - the point of lowest reflectance) to longer wavelength: 8.6 μm. The glass beads dominate the spectrum, displaying a broad peak around the main Si-O stretch band (at 10.8 μm). As such, individual mineral components of this sample cannot be resolved from the average spectrum alone. Apollo 67481,96 is a sub-mature regolith composed dominantly of anorthite plagioclase [2]. The CF position of the average spectrum is shifted to shorter wavelengths (8.2 μm) due to the higher proportion of felsic minerals. Its average spectrum is dominated by anorthite reflectance bands at 8.7, 9.1, 9.8, and 10.8 μm. The average reflectance is greater than the other samples due to a lower proportion of glassy material. In each soil, the smallest fractions (0-25 and 25-63 μm) have CF positions 0.1-0.4 μm higher than the larger grain sizes. Also, the bulk-sample spectra mostly closely resemble the 0-25 μm sieved size fraction spectrum, indicating that this size fraction of each sample dominates the bulk spectrum regardless of other physical properties. This has implications for surface analyses of other Solar System bodies where some mineral phases or components could be concentrated in a particular size fraction. For example, the anorthite grains in 67481,96 are dominantly >25 μm in size and therefore may not contribute proportionally to the bulk average spectrum (compared to the <25 μm fraction). The resulting bulk spectrum of 67481,96 has a CF position 0.2 μm higher than all size fractions >25 microns and therefore does not represent a true average composition of the sample. Further investigation of how grain size and composition alters the average spectrum is required to fully understand infrared spectra of planetary surfaces. [1] - Hiesinger H., Helbert J., and MERTIS Co-I Team. (2010). The Mercury Radiometer and Thermal Infrared Spectrometer (MERTIS) for the BepiColombo Mission. Planetary and Space Science. 58, 144-165. [2] - NASA Lunar Sample Compendium. https://curator.jsc.nasa.gov/lunar/lsc/
Later-borns Don't Give Up: The Temporary Effects of Birth Order on European Earnings.
Bertoni, Marco; Brunello, Giorgio
2016-04-01
The existing empirical evidence on the effects of birth order on wages does not distinguish between temporary and permanent effects. Using data from 11 European countries for males born between 1935 and 1956, we show that firstborns enjoy on average a 13.7% premium in their entry wage compared with later-borns. This advantage, however, is short-lived and disappears 10 years after labor market entry. Although firstborns start with a better job, partially because of their higher education, later-borns quickly catch up by switching earlier and more frequently to better-paying jobs. We argue that a key factor driving our findings is that later-borns have lower risk aversion than firstborns.
Temperature alters food web body-size structure.
Gibert, Jean P; DeLong, John P
2014-08-01
The increased temperature associated with climate change may have important effects on body size and predator-prey interactions. The consequences of these effects for food web structure are unclear because the relationships between temperature and aspects of food web structure such as predator-prey body-size relationships are unknown. Here, we use the largest reported dataset for marine predator-prey interactions to assess how temperature affects predator-prey body-size relationships among different habitats ranging from the tropics to the poles. We found that prey size selection depends on predator body size, temperature and the interaction between the two. Our results indicate that (i) predator-prey body-size ratios decrease with predator size at below-average temperatures and increase with predator size at above-average temperatures, and (ii) that the effect of temperature on predator-prey body-size structure will be stronger at small and large body sizes and relatively weak at intermediate sizes. This systematic interaction may help to simplify forecasting the potentially complex consequences of warming on interaction strengths and food web stability. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Improving excellence in scoliosis rehabilitation: a controlled study of matched pairs.
Weiss, H-R; Klein, R
2006-01-01
Physiotherapy programmes so far mainly address the lateral deformity of scoliosis, a few aim at the correction of rotation and only very few address the sagittal profile. Meanwhile, there is evidence that correction forces applied in the sagittal plane are also able to correct the scoliotic deformity in the coronal and frontal planes. So it should be possible to improve excellence in scoliosis rehabilitation by the implementation of exercises to correct the sagittal deformity in scoliosis patients. An exercise programme (physio-logic exercises) aiming at a physiologic sagittal profile was developed to add to the programme applied at the centre or to replace certain exercises or exercising positions. To test the hypothesis that physio-logic exercises improve the outcome of Scoliosis Intensive Rehabilitation (SIR), the following study design was chosen: Prospective controlled trial of pairs of patients with idiopathic scoliosis matched by sex, age, Cobb angle and curve pattern. There were 18 patients in the treatment group (SIR + physio-logic exercises) and 18 patients in the control group (SIR only), all in matched pairs. Average Cobb angle in the treatment group was 34.5 degrees (SD 7.8) Cobb angle in the control group was 31.6 degrees (SD 5.8). Age in the treatment group was at average 15.3 years (SD 1.1) and in the control group 14.7 years (SD 1.3). Thirteen of the 18 patients in either group had a brace. Outcome parameter: average lateral deviation (mm), average surface rotation ( degrees ) and maximum Kyphosis angle ( degrees ) as evaluated with the help of surface topography (Formetric-system). Lateral deviation (mm) decreased significantly after the performance of the physio-logic programme and highly significantly in the physio-logic ADL posture; however, it was not significant after completion of the whole rehabilitation programme (2.3 vs 0.3 mm in the controls). Surface rotation improved at average 1.2 degrees in the treatment group and 0.8 degrees in the controls while Kyphosis angle did not improve in both groups. The physio-logic programme has to be regarded as a useful 'add on' to Scoliosis Rehabilitation with regards to the lateral deviation of the scoliotic trunk. A longitudinal controlled study is necessary to evaluate the long-term effect of the the physio-logic programme also with the help of X-rays.
Roth, Joshua D; Howell, Stephen M; Hull, Maury L
2018-06-01
Following total knee arthroplasty (TKA), high tibial forces, large differences in tibial forces between the medial and lateral compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion indicate abnormal knee function. Because the goal of kinematically aligned TKA is to restore native knee function without soft tissue release, the objectives were to determine how well kinematically aligned TKA limits high tibial forces, differences in tibial forces between compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion. Using cruciate retaining components, kinematically aligned TKA was performed on thirteen human cadaveric knee specimens with use of manual instruments without soft tissue release. The tibial forces and tibial contact locations were measured in both the medial and lateral compartments from 0° to 120° of passive flexion using a custom tibial force sensor. The average total tibial force (i.e. sum of medial + lateral) ranged from 5 to 116 N. The only significant average differences in tibial force between compartments occurred at 0° of flexion (29 N, p = 0.0008). The contact locations in both compartments translated posteriorly in all thirteen kinematically aligned TKAs by an average of 14 mm (p < 0.0001) and 18 mm (p < 0.0001) in the medial and lateral compartments, respectively, from 0° to 120° of flexion. After kinematically aligned TKA, average total tibial forces due to the soft tissue restraints were limited to 116 N, average differences in tibial forces between compartments were limited to 29 N, and a net posterior translation of the tibial contact locations was observed in all kinematically aligned TKAs during passive flexion from 0° to 120°, which are similar to what has been measured previously in native knees. While confirmation in vivo is warranted, these findings give surgeons who perform kinematically aligned TKA confidence that the alignment method and surgical technique limit high tibial forces, differences in tibial forces between compartments, and anterior translation of the tibial contact locations during passive flexion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Dongxu, E-mail: dongxu-wang@uiowa.edu; Dirksen, Blake; Hyer, Daniel E.
Purpose: To determine the plan quality of proton spot scanning (SS) radiosurgery as a function of spot size (in-air sigma) in comparison to x-ray radiosurgery for treating peripheral brain lesions. Methods: Single-field optimized (SFO) proton SS plans with sigma ranging from 1 to 8 mm, cone-based x-ray radiosurgery (Cone), and x-ray volumetric modulated arc therapy (VMAT) plans were generated for 11 patients. Plans were evaluated using secondary cancer risk and brain necrosis normal tissue complication probability (NTCP). Results: For all patients, secondary cancer is a negligible risk compared to brain necrosis NTCP. Secondary cancer risk was lower in proton SSmore » plans than in photon plans regardless of spot size (p = 0.001). Brain necrosis NTCP increased monotonically from an average of 2.34/100 (range 0.42/100–4.49/100) to 6.05/100 (range 1.38/100–11.6/100) as sigma increased from 1 to 8 mm, compared to the average of 6.01/100 (range 0.82/100–11.5/100) for Cone and 5.22/100 (range 1.37/100–8.00/100) for VMAT. An in-air sigma less than 4.3 mm was required for proton SS plans to reduce NTCP over photon techniques for the cohort of patients studied with statistical significance (p = 0.0186). Proton SS plans with in-air sigma larger than 7.1 mm had significantly greater brain necrosis NTCP than photon techniques (p = 0.0322). Conclusions: For treating peripheral brain lesions—where proton therapy would be expected to have the greatest depth-dose advantage over photon therapy—the lateral penumbra strongly impacts the SS plan quality relative to photon techniques: proton beamlet sigma at patient surface must be small (<7.1 mm for three-beam single-field optimized SS plans) in order to achieve comparable or smaller brain necrosis NTCP relative to photon radiosurgery techniques. Achieving such small in-air sigma values at low energy (<70 MeV) is a major technological challenge in commercially available proton therapy systems.« less
Jankovic, Zorica B; du Feu, Frances M; McConnell, Patricia
2009-09-01
The transversus abdominis plane (TAP) block is a new technique for providing analgesia to the anterior abdominal wall. Most previous studies have used the lumbar triangle of Petit as a landmark for the block. In this cadaveric study, we determined the exact position and size of the lumbar triangle of Petit and identified the nerves affected by the TAP block. The position of the lumbar triangle of Petit was assessed unilaterally in 26 cadaveric specimens relative to reliably palpable surface landmarks. In addition, a series of dissections were performed to explore the course of the nerves blocked by the TAP. The mean distance from the midaxillary line along the iliac crest to the center of the base of the lumbar triangle of Petit at the level of the subcutaneous tissue and over the skin surface was 6.9 cm (range, 4.5-9.2 cm) and 9.3 cm (range, 4-15.1 cm), respectively. The center of the lumbar triangle of Petit was 1.4 cm above the iliac crest. The depth of the TAP at the lumbar triangle of Petit position was 0.5-4 cm and at the midaxillary line it was 0.5-2 cm. The average size of the lumbar triangle of Petit was 2.3 cm x 3.3 cm x 2.2 cm, with an average area of 3.63 +/- 1.93 cm2. The three cadaveric specimens we explored showed the nerves blocked by TAP passed lateral to the triangle. An incidental finding was that in 66% of specimens the lumbar triangle of Petit contained small branches of the subcostal artery. The lumbar triangles of Petit found in the specimens in this study were more posterior than the literature suggests. The position of the lumbar triangle of Petit varies largely and the size is relatively small. The relevant nerves to be blocked had not entered the TAP in the specimens in this study at the point of the lumbar triangle of Petit. At the midaxillary line, however, all the nerves were in the TAP.
On the properties of a bundle of flexible actin filaments in an optical trap.
Perilli, Alessia; Pierleoni, Carlo; Ciccotti, Giovanni; Ryckaert, Jean-Paul
2016-06-28
We establish the statistical mechanics framework for a bundle of Nf living and uncrosslinked actin filaments in a supercritical solution of free monomers pressing against a mobile wall. The filaments are anchored normally to a fixed planar surface at one of their ends and, because of their limited flexibility, they grow almost parallel to each other. Their growing ends hit a moving obstacle, depicted as a second planar wall, parallel to the previous one and subjected to a harmonic compressive force. The force constant is denoted as the trap strength while the distance between the two walls as the trap length to make contact with the experimental optical trap apparatus. For an ideal solution of reactive filaments and free monomers at fixed free monomer chemical potential μ1, we obtain the general expression for the grand potential from which we derive averages and distributions of relevant physical quantities, namely, the obstacle position, the bundle polymerization force, and the number of filaments in direct contact with the wall. The grafted living filaments are modeled as discrete Wormlike chains, with F-actin persistence length ℓp, subject to discrete contour length variations ±d (the monomer size) to model single monomer (de)polymerization steps. Rigid filaments (ℓp = ∞), either isolated or in bundles, all provide average values of the stalling force in agreement with Hill's predictions Fs (H)=NfkBTln(ρ1/ρ1c)/d, independent of the average trap length. Here ρ1 is the density of free monomers in the solution and ρ1c its critical value at which the filament does not grow nor shrink in the absence of external forces. Flexible filaments (ℓp < ∞) instead, for values of the trap strength suitable to prevent their lateral escape, provide an average bundle force and an average trap length slightly larger than the corresponding rigid cases (few percents). Still the stalling force remains nearly independent on the average trap length, but results from the product of two strongly L-dependent contributions: the fraction of touching filaments ∝〈L〉(O.T.) (2) and the single filament buckling force ∝〈L〉(O.T.) (-2).
Creation of sidewall aneurysm in rabbits: aneurysm patency and growth follow-up.
Ding, Yong Hong; Tieu, Tai; Kallmes, David F
2014-01-01
To explore the patency and growth of surgical sidewall aneurysms in rabbits. Forty sidewall aneurysms were created in the right common carotid artery (RCCA). Intravenous digital subtraction angiography (DSA) through the ear vein was performed immediately after creation. Three weeks later, intra-arterial DSA through the femoral artery was performed. Aneurysm sizes (neck, width, height and volume) were measured and calculated immediately after creation and 3 weeks later. Aneurysm patency after creation was evaluated. Differences in aneurysm sizes immediately after creation and 3 weeks later were compared using the Student's t test. Aneurysms and the parent artery remained patent in 38 (95%) of the 40 rabbits 3 weeks after creation. Two other rabbits (5%) showed aneurysm occlusion. There was a significant difference in aneurysm neck size 3 weeks after creation (3.6±0.9 mm vs 2.4±0.4 mm, p<0.0001). The aneurysm became wider 3 weeks later (5.8±1.5 mm vs 4.3±1.2 mm, p<0.0001). Aneurysm length was also larger than immediately after creation (6.1±1.3 mm vs 4.3±1.4 mm, p<0.0001). The aneurysm volume was larger than that created immediately (127.5±89.4 mm(3) vs 51.0±34.9 mm(3), p<0.0001). The patency rate of sidewall aneurysms in rabbits is high. The aneurysm keeps growing for at least 3 weeks after creation.
Wang, Zhuochen; Heath Martin, K; Huang, Wenbin; Dayton, Paul A; Jiang, Xiaoning
2017-02-01
Techniques to image the microvasculature may play an important role in imaging tumor-related angiogenesis and vasa vasorum associated with vulnerable atherosclerotic plaques. However, the microvasculature associated with these pathologies is difficult to detect using traditional B-mode ultrasound or even harmonic imaging due to small vessel size and poor differentiation from surrounding tissue. Acoustic angiography, a microvascular imaging technique that utilizes superharmonic imaging (detection of higher order harmonics of microbubble response), can yield a much higher contrast-to-tissue ratio than second harmonic imaging methods. In this paper, two dual-frequency transducers using lateral mode transmitters were developed for superharmonic detection and acoustic angiography imaging in intracavity applications. A single element dual-frequency intravascular ultrasound transducer was developed for concept validation, which achieved larger signal amplitude, better contrast-to-noise ratio (CNR), and pulselength compared to the previous work. A dual-frequency [Pb(Mg 1/3 Nb 2/3 )O 3 ]-x[PbTiO 3 ] array transducer was then developed for superharmonic imaging with dynamic focusing. The axial and lateral sizes of the microbubbles in a 200- [Formula: see text] tube were measured to be 269 and [Formula: see text], respectively. The maximum CNR was calculated to be 22 dB. These results show that superharmonic imaging with a low frequency lateral mode transmitter is a feasible alternative to thickness mode transmitters when the final transducer size requirements dictate design choices.
School Bullying and Drug Use Later in Life: A Meta-Analytic Investigation
ERIC Educational Resources Information Center
Ttofi, Maria M.; Farrington, David P.; Lösel, Friedrich; Crago, Rebecca V.; Theodorakis, Nikolaos
2016-01-01
The main aim of this article is to investigate whether there is a significant long-term association between bullying at school and drug use later in life. A meta-analysis is presented based on results from major prospective longitudinal studies with available unadjusted and adjusted effect sizes. Results are based on thorough systematic searches…
40 CFR 600.507-08 - Running change data requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's...
40 CFR 600.507-12 - Running change data requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's...
40 CFR 600.507-86 - Running change data requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Model Year 1978 Passenger Automobiles and for 1979 and Later Model Year Automobiles (Light Trucks and Passenger Automobiles)-Procedures for Determining Manufacturer's Average Fuel Economy and Manufacturer's...
The crust of the Moon as seen by GRAIL.
Wieczorek, Mark A; Neumann, Gregory A; Nimmo, Francis; Kiefer, Walter S; Taylor, G Jeffrey; Melosh, H Jay; Phillips, Roger J; Solomon, Sean C; Andrews-Hanna, Jeffrey C; Asmar, Sami W; Konopliv, Alexander S; Lemoine, Frank G; Smith, David E; Watkins, Michael M; Williams, James G; Zuber, Maria T
2013-02-08
High-resolution gravity data obtained from the dual Gravity Recovery and Interior Laboratory (GRAIL) spacecraft show that the bulk density of the Moon's highlands crust is 2550 kilograms per cubic meter, substantially lower than generally assumed. When combined with remote sensing and sample data, this density implies an average crustal porosity of 12% to depths of at least a few kilometers. Lateral variations in crustal porosity correlate with the largest impact basins, whereas lateral variations in crustal density correlate with crustal composition. The low-bulk crustal density allows construction of a global crustal thickness model that satisfies the Apollo seismic constraints, and with an average crustal thickness between 34 and 43 kilometers, the bulk refractory element composition of the Moon is not required to be enriched with respect to that of Earth.
Joordens, Josephine C A; Kuipers, Remko S; Wanink, Jan H; Muskiet, Frits A J
2014-12-01
From c. 2 Ma (millions of years ago) onwards, hominin brain size and cognition increased in an unprecedented fashion. The exploitation of high-quality food resources, notably from aquatic ecosystems, may have been a facilitator or driver of this phenomenon. The aim of this study is to contribute to the ongoing debate on the possible role of aquatic resources in hominin evolution by providing a more detailed nutritional context. So far, the debate has focused on the relative importance of terrestrial versus aquatic resources while no distinction has been made between different types of aquatic resources. Here we show that Indian Ocean reef fish and eastern African lake fish yield on average similarly high amounts of eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA), and arachidonic acid (AA). Hence a shift from exploiting tropical marine to freshwater ecosystems (or vice versa) would entail no material difference in dietary long-chain polyunsaturated fatty acid (LC-PUFA) availability. However, a shift to marine ecosystems would likely mean a major increase in access to brain-selective micronutrients such as iodine. Fatty fish from marine temperate/cold waters yield twice as much DHA and four times as much EPA as tropical fish, demonstrating that a latitudinal shift in exploitation of African coastal ecosystems could constitute a significant difference in LC-PUFA availability with possible implications for brain development and functioning. We conclude that exploitation of aquatic food resources could have facilitated the initial moderate hominin brain increase as observed in fossils dated to c. 2 Ma, but not the exceptional brain increase in later stages of hominin evolution. We propose that the significant expansion in hominin brain size and cognition later on may have been aided by strong directional selecting forces such as runaway sexual selection of intelligence, and nutritionally supported by exploitation of high-quality food resources in stable and productive aquatic ecosystems. Copyright © 2014 Elsevier Ltd. All rights reserved.
Homo erectus and Middle Pleistocene hominins: brain size, skull form, and species recognition.
Rightmire, G Philip
2013-09-01
Hominins that differ from Homo erectus, the Neanderthals, and recent humans are known from Middle Pleistocene localities across the Old World. The taxonomic status of these populations has been clouded by controversy. Perhaps the most critical problem has been an incomplete understanding of variation in skull form. Here, both H. erectus and later mid-Pleistocene hominins are the focus of an investigation aimed at clarifying the relationships among brain volume, basicranial dimensions, neurocranial shape, and certain facial characters. Brain size in H. erectus averages about 950 cm(3), while in a series of Middle Pleistocene crania from Africa and Europe, volume is about 1230 cm(3). If encephalization is the primary mechanism operating in the mid-Pleistocene, then diverse aspects of cranial form cannot all be treated as independent variables. Correlation is utilized to examine the associations among measurements for more than 30 H. erectus crania that are reasonably well preserved. A similar approach is used with the Middle Pleistocene sample. Patterns of covariation are compared in order to assess integration. Next, factor analysis is applied to the H. erectus specimens in an attempt to identify modules, tightly integrated traits that can evolve independently. Studies of the variation within H. erectus are followed by direct comparisons with the Middle Pleistocene population. Discriminant functions facilitate the description of intergroup differences. Traits that vary independently from brain volume include anterior frontal broadening, lateral expansion of the parietal vault, elevation of the lambda-inion chord, and rounding of the sagittal contour of the occipital. This finding helps to resolve the problem of species recognition. Neurocranial proportions as well as characters from the cranial base and face can be incorporated into a differential diagnosis for the mid-Pleistocene sample. Evidence presented here supports arguments for speciation in the Middle Pleistocene. Copyright © 2013 Elsevier Ltd. All rights reserved.
Endogenous GLP-1 in lateral septum contributes to stress-induced hypophagia.
Terrill, Sarah J; Maske, Calyn B; Williams, Diana L
2018-03-03
Glucagon-like peptide 1 (GLP-1) neurons of the caudal brainstem project to many brain areas, including the lateral septum (LS), which has a known role in stress responses. Previously, we showed that endogenous GLP-1 in the LS plays a physiologic role in the control of feeding under non-stressed conditions, however, central GLP-1 is also involved in behavioral and endocrine responses to stress. Here, we asked whether LS GLP-1 receptors (GLP-1R) contribute to stress-induced hypophagia. Male rats were implanted with bilateral cannulas targeting the dorsal subregion of the LS (dLS). In a within-subjects design, shortly before the onset of the dark phase, rats received dLS injections of saline or the GLP-1R antagonist Exendin (9-39) (Ex9) prior to 30 min restraint stress. Food intake was measured continuously for the next 20 h. The stress-induced hypophagia observed within the first 30 min of dark was not influenced by Ex9 pretreatment, but Ex9 tended to blunt the effect of stress as early as 1 and 2 h into the dark phase. By 4-6 h, there were significant stress X drug interactions, and Ex9 pretreatment blocked the stress-induced suppression of feeding. These effects were mediated entirely through changes in average meal size; stress suppressed meal size while dLS Ex9 attenuated this effect. Using a similar design, we examined the role of dLS GLP-1R in the neuroendocrine response to acute restraint stress. As expected, stress potently increased serum corticosterone, but blockade of dLS GLP-1Rs did not affect this response. Together, these data show that endogenous GLP-1 action in the dLS plays a role in some but not all of the physiologic responses to acute stress. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winslow, J; Hurwitz, L; Christianson, O
2014-06-01
Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HDmore » scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose.« less
[Razemon's lateral digital rotation flap in severe Dupuytren contracture of the fifth finger].
Ould-Slimane, M; Guinet, V; Foulongne, E; Melconian, A; Beccari, R; Milliez, P-Y; Auquit-Auckbur, I
2013-10-01
In Dupuytren's disease, correction of severe contracture deformities and excision of dermal lesions are often responsible for palmar skin defects. This study aimed to assess the results of the lateral digital flap described by Razemon. Thirty-seven patients were analysed retrospectively for functional and trophic results. Twelve months of follow-up were at least required. The lack of extension was appreciated through Thomine's coefficient. Subjective patient's opinion was noted about function of fifth finger and hand. The flap trophicity was evaluated through softness, coverage quality and esthetic aspect. In the preoperative period, the average lack of extension was 105°; 89% of the patients were ranked as stages 3 or 4 of Tubiana's classification. At the 12th month, the average Thomine's coefficient was 0.74; 70% of the patients were very satisfied. Two patients exhibited some lack of suppleness and seven a dyschromic scars. The lateral digital rotation flap is a quite simple surgical procedure. It allows satisfactory results corresponding to functional and trophic coverage in severe Dupuytren's contracture involving the fifth finger. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Muller, Bart; Hofbauer, Marcus; Rahnemai-Azar, Amir Ata; Wolf, Megan; Araki, Daisuke; Hoshino, Yuichi; Araujo, Paulo; Debski, Richard E; Irrgang, James J; Fu, Freddie H; Musahl, Volker
2016-01-01
The pivot shift test is a commonly used clinical examination by orthopedic surgeons to evaluate knee function following injury. However, the test can only be graded subjectively by the examiner. Therefore, the purpose of this study is to develop software for a computer tablet to quantify anterior translation of the lateral knee compartment during the pivot shift test. Based on the simple image analysis method, software for a computer tablet was developed with the following primary design constraint - the software should be easy to use in a clinical setting and it should not slow down an outpatient visit. Translation of the lateral compartment of the intact knee was 2.0 ± 0.2 mm and for the anterior cruciate ligament-deficient knee was 8.9 ± 0.9 mm (p < 0.001). Intra-tester (ICC range = 0.913 to 0.999) and inter-tester (ICC = 0.949) reliability were excellent for the repeatability assessments. Overall, the average percent error of measuring simulated translation of the lateral knee compartment with the tablet parallel to the monitor increased from 2.8% at 50 cm distance to 7.7% at 200 cm. Deviation from the parallel position of the tablet did not have a significant effect until a tablet angle of 45°. Average percent error during anterior translation of the lateral knee compartment of 6mm was 2.2% compared to 6.2% for 2 mm of translation. The software provides reliable, objective, and quantitative data on translation of the lateral knee compartment during the pivot shift test and meets the design constraints posed by the clinical setting.
Small Scale and School Culture: The Experience of Private Schools. ERIC Digest.
ERIC Educational Resources Information Center
Conway, George E.
It is a widely held perception in this country that private schools are superior to public schools. This digest examines school size and school culture as they relate to the high quality of education in private schools. The average private school is about half the size of the average public school. Reflecting Tonnies' (Ferdinand Tonnies, 1887)…
2017-09-01
ADCP locations used for model calibration. ......................................................................... 12 Figure 4-3. Sample water...Example of fine sediment sample [Set d, Sample B30]. (B) Example of coarse sediment sample [Set d, sample B05...Turning Basin average sediment size distribution curve. ................................................... 21 Figure 5-5. Turning Basin average size
Paul F. Hessburg; Bradley G. Smith; Scott D. Kreiter; Craig A. Miller; Cecilia H. McNicoll; Michele. Wasienko-Holland
2000-01-01
In the interior Columbia River basin midscale ecological assessment, we mapped and characterized historical and current vegetation composition and structure of 337 randomly sampled subwatersheds (9500 ha average size) in 43 subbasins (404 000 ha average size). We compared landscape patterns, vegetation structure and composition, and landscape vulnerability to wildfires...
Bassen, David M; Hou, Yubo; Bowser, Samuel S; Banavali, Nilesh K
2016-08-19
Microtubules in foraminiferan protists (forams) can convert into helical filament structures, in which longitudinal intraprotofilament interactions between tubulin heterodimers are thought to be lost, while lateral contacts across protofilaments are still maintained. The coarse geometric features of helical filaments are known through low-resolution negative stain electron microscopy (EM). In this study, geometric restraints derived from these experimental data were used to generate an average atomic-scale helical filament model, which anticipated a modest reorientation in the lateral tubulin heterodimer interface. Restrained molecular dynamics (MD) simulations of the nearest neighbor interactions combined with a Genalized Born implicit solvent model were used to assess the lateral, longitudinal, and seam contacts in 13-3 microtubules and the reoriented lateral contacts in the helical filament model. This electrostatic analysis suggests that the change in the lateral interface in the helical filament does not greatly diminish the lateral electrostatic interaction. After longitudinal dissociation, the 13-3 seam interaction is much weaker than the reoriented lateral interface in the helical filament model, providing a plausible atomic-detail explanation for seam-to-lateral contact transition that enables the transition to a helical filament structure.
NASA Astrophysics Data System (ADS)
Bassen, David M.; Hou, Yubo; Bowser, Samuel S.; Banavali, Nilesh K.
2016-08-01
Microtubules in foraminiferan protists (forams) can convert into helical filament structures, in which longitudinal intraprotofilament interactions between tubulin heterodimers are thought to be lost, while lateral contacts across protofilaments are still maintained. The coarse geometric features of helical filaments are known through low-resolution negative stain electron microscopy (EM). In this study, geometric restraints derived from these experimental data were used to generate an average atomic-scale helical filament model, which anticipated a modest reorientation in the lateral tubulin heterodimer interface. Restrained molecular dynamics (MD) simulations of the nearest neighbor interactions combined with a Genalized Born implicit solvent model were used to assess the lateral, longitudinal, and seam contacts in 13-3 microtubules and the reoriented lateral contacts in the helical filament model. This electrostatic analysis suggests that the change in the lateral interface in the helical filament does not greatly diminish the lateral electrostatic interaction. After longitudinal dissociation, the 13-3 seam interaction is much weaker than the reoriented lateral interface in the helical filament model, providing a plausible atomic-detail explanation for seam-to-lateral contact transition that enables the transition to a helical filament structure.
NASA Astrophysics Data System (ADS)
Chen, Wo-Hsing; Sanghvi, Narendra T.; Carlson, Roy; Schatzl, Georg; Marberger, Michael
2012-10-01
The Sonablate® 500 has quantitative, real-time Tissue Change Monitoring (TCM) software that estimates changes in tissue properties due to HIFU treatment of prostate cancer. This study validates the Sonablate 500 TCM system using real-time thermometry. Five patients with histologically confirmed, organ-confined prostate cancer were enrolled. Four patients with focal cancer had hemiablation and one had whole gland ablation. TCM generates energy reading based on spectral analysis on the RF backscattered ultrasound signals; results are used as an estimator of tissue temperature. Needle thermocouples were placed transperineally under TRUS guidance in the prostate to monitor temperatures from focal zone, posterior to the focal zone and on the lateral gland where no HIFU was applied. The HIFU treatments averaged 37, 35 and 19.7 Watts for the treatment for anterior, middle and posterior zones. The measured temperatures (Average, Max, and Min) in the HIFU treatment zones were 84, 114 and 70 degrees C. The temperature estimated by TCM energy readings were 83% 75-100 degrees C and 17% 60-75 degrees C with an average of 91 degrees C. Outside the focal zone, average recorded temperature was 50 degrees C. Average temperature in the lateral lobe where no HIFU was applied was 40.7 degrees C.
The clavicle hook plate for Neer type II lateral clavicle fractures.
Renger, R J; Roukema, G R; Reurings, J C; Raams, P M; Font, J; Verleisdonk, E J M M
2009-09-01
To evaluate functional and radiologic outcome in patients with a Neer type II lateral clavicle fracture treated with the clavicle hook plate. Multicenter retrospective study. Five level I and II trauma centers. Forty-four patients, average age 38.4 years (18-66 years), with a Neer type II lateral clavicle fracture treated with the clavicle hook plate between January 1, 2003, and December 31, 2006. Open reduction and internal fixation with the clavicle hook plate. Removal of all 44 implants after consolidation at a mean of 8.4 months (2-33 months) postoperatively. At an average follow-up of 27.4 months (13-48 months), functional outcome was assessed with the Constant-Murley scoring system. Radiographs were taken to evaluate consolidation and to determine the distance between the coracoid process and the clavicle. The average Constant score was 92.4 (74-100). The average distance between the coracoid process and the clavicle was 9.8 mm (7.3-14.8 mm) compared with 9.4 mm (6.9-14.3 mm) on the contralateral nonoperative side. We observed 1 dislocation of an implant (2.2%), 2 cases of pseudarthrosis (4.5%), 2 superficial wound infections (4.5%), 2 patients with hypertrophic scar tissue (4.5%), and 3 times an acromial osteolysis (6.8%). Thirty patients (68%) reported discomfort due to the implant. These implant-related complaints and the acromial osteolysis disappeared after removal of the hook plate. With all the patients, direct functional aftercare was possible. The clavicle hook plate is a suitable implant for Neer type II clavicle fractures. The advantage of this osteosynthesis is the possibility of immediate functional aftercare. We observed a high percentage of discomfort due to the implant; therefore, we advise to remove the implant as soon as consolidation has taken place.