Sample records for average payback period

  1. An economic analysis comparison of stationary and dual-axis tracking grid-connected photovoltaic systems in the US Upper Midwest

    NASA Astrophysics Data System (ADS)

    Choi, Wongyu; Pate, Michael B.; Warren, Ryan D.; Nelson, Ron M.

    2018-05-01

    This paper presents an economic analysis of stationary and dual-axis tracking photovoltaic (PV) systems installed in the US Upper Midwest in terms of life-cycle costs, payback period, internal rate of return, and the incremental cost of solar energy. The first-year performance and energy savings were experimentally found along with documented initial cost. Future PV performance, savings, and operating and maintenance costs were estimated over 25-year assumed life. Under the given assumptions and discount rates, the life-cycle savings were found to be negative. Neither system was found to have payback periods less than the assumed system life. The lifetime average incremental costs of energy generated by the stationary and dual-axis tracking systems were estimated to be 0.31 and 0.37 per kWh generated, respectively. Economic analyses of different scenarios, each having a unique set of assumptions for costs and metering, showed a potential for economic feasibility under certain conditions when compared to alternative investments with assumed yields.

  2. Techno-economical assessment of grid connected PV/T using nanoparticles and water as base-fluid systems in Malaysia

    NASA Astrophysics Data System (ADS)

    Al-Waeli, Ali H. A.; Kazem, Hussein A.; Sopian, K.; Chaichan, Miqdam T.

    2018-07-01

    In this study, the techno-economic assessment of GCPVT with nanofluid has been investigated based on theoretical and experimental work in Malaysia. The productivity and utilisation of the PV have been investigated using yield and capacity factors (CFs), respectively. Also, the cost of energy and payback period has been calculated. The system installed, tested, and data have been collected. Evaluation of the system in terms of current, voltage, power and efficiency are presented. The average daily ambient temperature and total global solar energy in Kuala Lumpur are 38.89°C and 4062 Wh/m2, respectively. MATLAB software is used to analyse the measured data. The assessment results show that the GCPVT system has annual yield factor, CF, the cost of energy; payback period, and efficiency are (128.34-183.75) kWh/kWp, (17.82-25.52)%, 0.196 USD/kWh, 7-8 years and 9.1%, respectively. This study indicates that the GCPVT system with nanofluid improved the PV technical and economic performance.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, weremore » achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.« less

  4. 77 FR 7281 - Energy Conservation Program: Energy Conservation Standards for Distribution Transformers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... Manufacturing Transformers H. Customer Subgroup Analysis I. Manufacturer Impact Analysis 1. Overview 2... Justification and Energy Savings 1. Economic Impacts on Customers a. Life-Cycle Cost and Payback Period b. Customer Subgroup Analysis c. Rebuttable-Presumption Payback 2. Economic Impact on Manufacturers a...

  5. Comparing energy payback and simple payback period for solar photovoltaic systems

    NASA Astrophysics Data System (ADS)

    Kessler, Will

    2017-11-01

    Installing a solar photovoltaic (PV) array is both an environmental and a financial decision. The financial arguments often take priority over the environmental because installing solar is capital-intensive. The Simple Payback period (SPB) is often assessed prior to the adoption of solar PV at a residence or a business. Although it better describes the value of solar PV electricity in terms of sustainability, the Energy Payback period (EPB) is seldom used to gauge the merits of an installation. Using published estimates of embodied energies, EPB was calculated for four solar PV plants utilizing crystalline-Si technology: three being actual commercial installations located in the northeastern U.S., and a fourth installation based on a simulated 20-kilowatt roof-mounted system, in Wrocław, Poland. Simple Payback was calculated based on initial capital cost, and on the availability of avoided electricity costs based on net-metering tariffs, which at present in the U.S. are 1:1 credit ratio, and in Poland is 1:0.7 credit ratio. For all projects, the EPB time was estimated at between 1.9 and 2.6 years. In contrast, the SPB for installed systems in the northeastern U.S. ranged from 13.3 to 14.6 years, and was estimated at 13.5 years for the example system in Lower Silesia, Poland. The comparison between SPB and EPB shows a disparity between motivational time frames, in which the wait for financial return is considerably longer than the wait for net energy harvest and the start of sustainable power production.

  6. Lighting Control Systems

    DTIC Science & Technology

    2004-02-26

    Shorter payback periods After 19 Cost Benefit of Powerlink Rule of Thumb for Powerlink: Powerlink becomes more cost effective beyond 16 controlled...web enabled control (and management software) Increase in level of integration between building systems Increase in new features, functions, benefits ...focus on reducing run-time via Scheduling, Sensing, Switching Growing focus on payback Direct energy cost (with demand) Additional maintenance benefits

  7. A Demonstration System for Capturing Geothermal Energy from Mine Waters beneath Butte, Montana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blackketter, Donald

    2015-06-01

    Executive Summary An innovative 50-ton ground-source heat pump (GSHP) system was installed to provide space heating and cooling for a 56,000 square foot (5,200 square meter) building in Butte Montana, in conjunction with its heating and chiller systems. Butte is a location with winter conditions much colder than the national average. The GSHP uses flooded mine waters at 78F (25C) as the heat source and heat sink. The heat transfer performance and efficiency of the system were analyzed using data from January through July 2014. This analysis indicated that for typical winter conditions in Butte, Montana, the GSHP could delivermore » about 88% of the building’s annual heating needs. Compared with a baseline natural-gas/electric system, the system demonstrated at least 69% site energy savings, 38% source energy savings, 39% carbon dioxide emissions reduction, and a savings of $17,000 per year (40%) in utility costs. Assuming a $10,000 per ton cost for installing a production system, the payback period at natural gas costs of $9.63/MMBtu and electricity costs of $0.08/kWh would be in the range of 40 to 50 years. At higher utility prices, or lower installation costs, the payback period would obviously be reduced.« less

  8. Survey Evidence on the Willingness of U.S. Consumers to Pay for Automotive Fuel Economy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greene, David L; Evans, David H; Hiestand, John

    2013-01-01

    Prospect theory, which was awarded the Nobel Prize in Economics in 2002, holds that human beings faced with a risky bet will tend to value potential losses about twice as much as potential gains. Previous research has demonstrated that prospect theory could be sufficient to explain an energy paradox in the market for automotive fuel economy. This paper analyzes data from four random sample surveys of 1,000 U.S. households each in 2004, 2011, 2012 and 2013. Households were asked about willingness to pay for future fuel savings as well as the annual fuel savings necessary to justify a given upfrontmore » payment. Payback periods inferred from household responses are consistent over time and across different formulations of questions. Mean calculated payback periods are short, about 3 years, but there is substantial dispersion among individual responses. Calculated payback periods do not appear to be correlated with the attributes of respondents. Respondents were able to quantitatively describe their uncertainty about both vehicle fuel economy and future fuel prices. Simulation of loss averse behavior based on this stated uncertainty illustrate how loss aversion could lead consumers to substantially undervalue future fuel savings relative to their expected value.« less

  9. Alcoa World Alumina: Plant-Wide Assessment at Arkansas Operations Reveals More than$900,000 in Potential Annual Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2003-07-01

    The plant-wide energy-efficiency assessment performed in 2001 at the Alcoa World Alumina Arkansas Operations in Bauxite, Arkansas, identified seven opportunities to save energy and reduce costs. By implementing five of these improvements, the facility can save 15,100 million British thermal units per year in natural gas and 8.76 million kilowatt-hours per year in electricity. This translates into approximate annual savings of$925,300 in direct energy costs and non-fuel operating and maintenance costs. The required capital investment is estimated at$271,200. The average payback period for all five projects would be approximately 8 months.

  10. Alcoa World Alumina: Plant Wide Assessment at Arkansas Operation Reveals More than $900,000 in Potential Annual Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2003-07-01

    The plant-wide energy-efficiency assessment performed in 2001 at the Alcoa World Alumina Arkansas Operations in Bauxite, Arkansas, identified seven opportunities to save energy and reduce costs. By implementing five of these improvements, the facility can save 15,100 million British thermal units per year in natural gas and 8.76 million kilowatt-hours per year in electricity. This translates into approximate annual savings of $925,300 in direct energy costs and non-fuel operating and maintenance costs. The required capital investment is estimated at $271,200. The average payback period for all five projects would be approximately 8 months.

  11. JT8D and JT9D jet engine performance improvement program. Task 1: Feasibility analysis

    NASA Technical Reports Server (NTRS)

    Gaffin, W. O.; Webb, D. E.

    1979-01-01

    JT8D and JT9D component performance improvement concepts which have a high probability of incorporation into production engines were identified and ranked. An evaluation method based on airline payback period was developed for the purpose of identifying the most promising concepts. The method used available test data and analytical models along with conceptual/preliminary designs to predict the performance improvements, weight, installation characteristics, cost for new production and retrofit, maintenance cost, and qualitative characteristics of candidate concepts. These results were used to arrive at the concept payback period, which is the time required for an airline to recover the investment cost of concept implementation.

  12. A Greenhouse Gas and Soil Carbon Model for Estimating the Carbon Footprint of Livestock Production in Canada

    PubMed Central

    Vergé, Xavier P.C.; Dyer, James A.; Worth, Devon E.; Smith, Ward N.; Desjardins, Raymond L.; McConkey, Brian G.

    2012-01-01

    Simple Summary We developed a model to estimate the carbon footprint of Canadian livestock production. To include long term soil carbon storage and loss potential we introduced a payback period concept. The model was tested by reallocating 10% only of the protein production from a ruminant to a non ruminant source to minimize the risk of including rangeland or marginal lands. This displacement generated residual land which was found to play a major role in the potential mitigation of GHG emissions. The model will allow land use policies aimed at reducing the agricultural GHG emissions to be assessed. Abstract To assess tradeoffs between environmental sustainability and changes in food production on agricultural land in Canada the Unified Livestock Industry and Crop Emissions Estimation System (ULICEES) was developed. It incorporates four livestock specific GHG assessments in a single model. To demonstrate the application of ULICEES, 10% of beef cattle protein production was assumed to be displaced with an equivalent amount of pork protein. Without accounting for the loss of soil carbon, this 10% shift reduced GHG emissions by 2.5 TgCO2e y−1. The payback period was defined as the number of years required for a GHG reduction to equal soil carbon lost from the associated land use shift. A payback period that is shorter than 40 years represents a net long term decrease in GHG emissions. Displacing beef cattle with hogs resulted in a surplus area of forage. When this residual land was left in ungrazed perennial forage, the payback periods were less than 4 years and when it was reseeded to annual crops, they were equal to or less than 40 years. They were generally greater than 40 years when this land was used to raise cattle. Agricultural GHG mitigation policies will inevitably involve a trade-off between production, land use and GHG emission reduction. ULICEES is a model that can objectively assess these trade-offs for Canadian agriculture. PMID:26487032

  13. Economic Viability of Pumped-Storage Power Plants Equipped with Ternary Units and Considering Hydraulic Short-Circuit Operation

    NASA Astrophysics Data System (ADS)

    Chazarra, Manuel; Pérez-Díaz, Juan I.; García-González, Javier

    2017-04-01

    This paper analyses the economic viability of pumped-storage hydropower plants equipped with ternary units and considering hydraulic short-circuit operation. The analysed plant is assumed to participate in the day-ahead energy market and in the secondary regulation service of the Spanish power system. A deterministic day-ahead energy and reserve scheduling model is used to estimate the maximum theoretical income of the plant assuming perfect information of the next day prices and the residual demand curves of the secondary regulation reserve market. Results show that the pay-back periods with and without the hydraulic short-circuit operation are significantly lower than their expected lifetime and that the pay-back periods can be reduced with the inclusion of the hydraulic short-circuit operation.

  14. 34 CFR 263.10 - What are the payback reporting requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for payments. (Approved by the Office of Management and Budget under control number 1810-0580... notice of intent to complete a work-related or cash payback, or to continue in a degree program as a full..., but cannot complete, a work-related payback, the payback reverts to a cash payback that is prorated...

  15. The potential for PVs in Greek commercial buildings

    NASA Astrophysics Data System (ADS)

    Samouil, Chris

    The photovoltaic sector has been growing explosively, worldwide, for the past few years. At present, grid-connected installations dominate the world market. The photovoltaic technology, types of systems, applications and the market of PVs are presented, placing emphasis on installations regarding the building sector. The main focus of the project is concentrated on Greece. The fact that Greece has favourable natural conditions for the exploitation of solar energy, coupled with the support scheme on phototovoltaics introduced with the new law on renewable energy sources voted in June 2006, makes it very interesting to invest in the Greek PV market. Using a newly built office building in Athens with a roof-top PV installation as a case study, this project looks at the viability of grid-connected systems in the building sector. The annual energy output of the system and CO2 emissions reduction were modelled. Embodied energy, installation cost and annual savings were also considered to determine payback periods. The economic payback period of the system was found to be shorter than its lifetime at 16.2 years, reducing to 9.7 years when grants were included. The carbon payback period was calculated at 6.3 years. A sensitivity analysis on the effect of different factors affecting the viability of the PV installation was carried out. Assuming constant electricity rate increases or a more favourable location for the project the results are more attractive. The same case study in Crete would have a payback period reduced by almost 20% compared to that in Athens. A method to extrapolate the findings for the whole building sector of Attica is proposed as a future research project. As an indication it is found that 60,000 similar to the base case roof-top PV systems can produce around 3.1% of the country's thermally produced electricity and save 0.9% of its CO2 emissions. Finally, the strengths and weeknesses of the new RES law are identified and suggestions are made in order to smoothen PV implementation in Greece.

  16. WaterSense at Work

    EPA Pesticide Factsheets

    Each of the 36 BMPs provides an overview of the technology, tips for operation, maintenance, and user education, options for retrofits and replacements, and calculations for potential water, energy, and dollar savings and payback periods.

  17. Stockbridge Munsee Community Health and Wellness Center and the Mohican Family Center Renewable Energy and Energy Efficiency Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeRocher, Andy; Barrnett, Michael

    2014-03-14

    The results of the Renewable Energy and Energy Efficiency Feasibility Study of Stockbridge Munsee Community’s Health and Wellness Center (HWC) indicate that a variety of renewable energy options and energy conservation measures (ECMs) exist for the facility. A requirement of the Request for Proposal for this study was to assess renewable energy options that could offset 30 to 100 percent of the HWC’s energy use. This study identifies that a geothermal system is the most cost effective renewable energy option available to decrease the HWC’s energy consumption by 30 to 100 percent. Currently the HWC performs in the lowest 8more » percent of buildings in its building category, as scored in the EPA portfolio manager benchmarking tool. Multiple ECM opportunities have been identified with paybacks of less than five years to yield an estimated 25-percent decrease in annual energyconsumption. The ECMs within this payback period are estimated to save $26,800 per year with an implementation cost of just $4,650 (0.2 year payback). For the Mohican Family Center document: The results of the Renewable Energy and Energy Efficiency Feasibility Study of Stockbridge Munsee Community’s Mohican Family Center (MFC) indicate that a variety of renewable energy options and energy conservation measures (ECMs) exist for the facility. A requirement of the Request for Proposal for this study was to assess renewable energy options that could offset 30 to 100 percent of the MFC’s energy use. This study identifies that a geothermal system is the most cost effective renewable energy option available to decrease the MFC’s energy consumption by 30 to 100 percent. Currently the MFC performs better than 80 percent of buildings in its building category, as scored in the EPA portfolio manager benchmarking tool. Multiple ECM opportunities have been identified with short term paybacks to yield an estimated 13-percent decrease in energy consumption. The ECMs within this payback period are estimated to save $3,100 per year with an implementation cost of under $20,000.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubin, F S; Halfon, A; Herzog, P

    The ice-generating HP-ICES uses the heat of fusion of water as a heat source for the heat pump, thus converting the water into ice. The ice will be stored in a bin and used the following summer for cooling which, therefore, could be considered a by-product of heating. The annual overall Coefficient of Performance is expected to reach a value of 4.85 and related to source energy a value of 4.85 x 0.31 = 1.5. In a detailed case study on the Market Square project in Washington, D.C., it was found that for the HP-ICES the annual source energy inputmore » is about 60% and the life cycle annual average cost is 40% of the corresponding quantities for a conventional central system with equal heating and cooling capacity. The annual average operating and administration cost for the HP-ICES is less than 70% of the corresponding costs for the conventional system, while the first cost of the HP-ICES is about 70% larger than the first cost of the conventional system. With the values assumed for the discount rate, interest rate, etc., the return on investment was found to be about 15%, which gives a discounted payback period of about 6.7 years. For the Park Plaza in Boston, the annual source energy input for the HP-ICES is 35% and the energy cost is about 30% of the corresponding quantities for the conventional system. The annual average operating and administration cost for the HP-ICES is 4.5 times as great as the first cost for the conventional system. The return on investment is 13% and the payback is 8 years. These results show that the HP-ICES can be better both in energy usage and in life cycle cost than a conventional system of the same heating and cooling capacity, and holds great promise as an energy saving system.« less

  19. Techno-economic analysis of lipase enzyme production from agro-industry waste with solid state fermentation method

    NASA Astrophysics Data System (ADS)

    Hidayatullah, I. M.; Arbianti, R.; Utami, T. S.; Suci, M.; Sahlan, M.; Wijanarko, A.; Gozan, M.; Hermansyah, H.

    2018-03-01

    Needs for this kind of catalyst derived from biological raw materials (biocatalysts) has increased along with development of products based on eco-friendly. To achieve the needs of biocatalyst (enzyme), large production is necessary. This study aimed to get the best conditions and design equipment to produce lipase enzyme based on solid state fermentation using SuperPro Designer v9.0. Several equipment such as Tray Bioreactor, Mixing Tank 1, Filter Press, centrifuge, Mixing Tank 2, and a dryer have been improved during the simulation. Economic analysis in the form of NPV, IRR, Payback Period, and the Benefit Cost Ratio was evaluated respectively. The result showed that production of 10 kg enzyme with NPV Rp112.796.147.423,00; IRR 54.20%; Payback Period 1.95 years; and Benefit Cost Ratio of 3.36 was more advantageous.

  20. Post-evaluation of a ground source heat pump system for residential space heating in Shanghai China

    NASA Astrophysics Data System (ADS)

    Lei, Y.; Tan, H. W.; Wang, L. Z.

    2017-11-01

    Residents of Southern China are increasingly concerned about the space heating in winter. The chief aim of the present work is to find a cost-effective way for residential space heating in Shanghai, one of the biggest city in south China. Economic and energy efficiency of three residential space heating ways, including ground source heat pump (GSHP), air source heat pump (ASHP) and wall-hung gas boiler (WHGB), are assessed based on Long-term measured data. The results show that the heat consumption of the building is 120 kWh/m2/y during the heating season, and the seasonal energy efficiency ratio (SEER) of the GSHP, ASHP and WHGB systems are 3.27, 2.30, 0.88 respectively. Compared to ASHP and WHGB, energy savings of GSHP during the heating season are 6.2 kgce/(m2.y) and 2.2 kgce/(m2.y), and the payback period of GSHP are 13.3 and 7.6 years respectively. The sensitivity analysis of various factors that affect the payback period is carried out, and the results suggest that SEER is the most critical factor affecting the feasibility of ground source heat pump application, followed by building load factor and energy price factor. These findings of the research have led the author to the conclusion that ground source heat pump for residential space heating in Shanghai is a good alternative, which can achieve significant energy saving benefits, and a good system design and operation management are key factors that can shorten the payback period.

  1. Development and Evaluation of Solar Tunnel Dryer for Commercial Fish Drying

    NASA Astrophysics Data System (ADS)

    Mohod, A. G.; Khandetod, Y. P.; Shrirame, H. Y.

    2014-01-01

    The local practice of drying fish in open sun drying poses problems such as high moisture content, uncontrolled drying and contamination. These problems can be avoided by proper use of improved methods such as the solar tunnel dryer, which results in faster drying of fish. The semi cylindrical walk-in type natural convection solar tunnel dryer, having drying area of 37.5 m2 was developed and evaluated for the drying of fish products in comparison with the conventional method of open sun drying. The experiments were conducted without fish and with fish to evaluate the performance of solar tunnel dryer. The average rise in temperature inside the solar tunnel dryer was found to be 11.24 °C and 18.29 °C over the ambient temperature during no load test in winter and summer respectively. The average 28 % saving in time was observed for selected fish drying using solar tunnel dryer over open sun drying method with average drying efficiency of 19 %. The economics was calculated for drying of prawns ( Parapaeneopsis stylifera) by solar tunnel dryer and open sun drying system on the basis of business as a whole. The economics of the solar tunnel dryer is presented in term of Net present worth, Benefit-Cost Ratio, Payback period, Profitability index and Internal rate of return. The pay back period for solar tunnel dryer was found to be 2.84 years.

  2. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  3. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  4. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  5. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  6. 10 CFR 455.71 - Eligibility.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... financial assistance is to be requested subsequent to the most recent construction, reconfiguration, or... Eligibility. (a) To be eligible to receive financial assistance for an energy conservation measure, including... which financial assistance is to be requested within the simple payback period or useful life (depending...

  7. Can biofuels be a solution to climate change? The implications of land use change-related emissions for policy

    PubMed Central

    Khanna, Madhu; Crago, Christine L.; Black, Mairi

    2011-01-01

    Biofuels have gained increasing attention as an alternative to fossil fuels for several reasons, one of which is their potential to reduce the greenhouse gas (GHG) emissions from the transportation sector. Recent studies have questioned the validity of claims about the potential of biofuels to reduce GHG emissions relative to the liquid fossil fuels they are replacing when emissions owing to direct (DLUC) and indirect land use changes (ILUC) that accompany biofuels are included in the life cycle GHG intensity of biofuels. Studies estimate that the GHG emissions released from ILUC could more than offset the direct GHG savings by producing biofuels and replacing liquid fossil fuels and create a ‘carbon debt’ with a long payback period. The estimates of this payback period, however, vary widely across biofuels from different feedstocks and even for a single biofuel across different modelling assumptions. In the case of corn ethanol, this payback period is found to range from 15 to 200 years. We discuss the challenges in estimating the ILUC effect of a biofuel and differences across biofuels, and its sensitivity to the assumptions and policy scenarios considered by different economic models. We also discuss the implications of ILUC for designing policies that promote biofuels and seek to reduce GHG emissions. In a first-best setting, a global carbon tax is needed to set both DLUC and ILUC emissions to their optimal levels. However, it is unclear whether unilateral GHG mitigation policies, even if they penalize the ILUC-related emissions, would increase social welfare and lead to optimal emission levels. In the absence of a global carbon tax, incentivizing sustainable land use practices through certification standards, government regulations and market-based pressures may be a viable option for reducing ILUC. PMID:22482030

  8. Trade-offs between forest carbon stocks and harvests in a steady state - A multi-criteria analysis.

    PubMed

    Pingoud, Kim; Ekholm, Tommi; Sievänen, Risto; Huuskonen, Saija; Hynynen, Jari

    2018-03-15

    This paper provides a perspective for comparing trade-offs between harvested wood flows and forest carbon stocks with different forest management regimes. A constant management regime applied to a forest area with an even age-class distribution leads to a steady state, in which the annual harvest and carbon stocks remain constant over time. As both are desirable - carbon stocks for mitigating climate change and harvests for the economic use of wood and displacing fossil fuels - an ideal strategy should be chosen from a set of management regimes that are Pareto-optimal in the sense of multi-criteria decision-making. When choosing between Pareto-optimal alternatives, the trade-off between carbon stock and harvests is unavoidable. This trade-off can be described e.g. in terms of carbon payback times or carbon returns. As numerical examples, we present steady-state harvest levels and carbon stocks in a Finnish boreal forest region for different rotation periods, thinning intensities and collection patterns for harvest residues. In the set of simulated management practices, harvest residue collection presents the most favorable trade-off with payback times around 30-40 years; while Pareto-optimal changes in rotation or thinnings exhibited payback times over 100 years, or alternatively carbon returns below 1%. By extending the rotation period and using less-intensive thinnings compared to current practices, the steady-state carbon stocks could be increased by half while maintaining current harvest levels. Additional cases with longer rotation periods should be also considered, but were here excluded due to the lack of reliable data on older forest stands. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Can biofuels be a solution to climate change? The implications of land use change-related emissions for policy.

    PubMed

    Khanna, Madhu; Crago, Christine L; Black, Mairi

    2011-04-06

    Biofuels have gained increasing attention as an alternative to fossil fuels for several reasons, one of which is their potential to reduce the greenhouse gas (GHG) emissions from the transportation sector. Recent studies have questioned the validity of claims about the potential of biofuels to reduce GHG emissions relative to the liquid fossil fuels they are replacing when emissions owing to direct (DLUC) and indirect land use changes (ILUC) that accompany biofuels are included in the life cycle GHG intensity of biofuels. Studies estimate that the GHG emissions released from ILUC could more than offset the direct GHG savings by producing biofuels and replacing liquid fossil fuels and create a 'carbon debt' with a long payback period. The estimates of this payback period, however, vary widely across biofuels from different feedstocks and even for a single biofuel across different modelling assumptions. In the case of corn ethanol, this payback period is found to range from 15 to 200 years. We discuss the challenges in estimating the ILUC effect of a biofuel and differences across biofuels, and its sensitivity to the assumptions and policy scenarios considered by different economic models. We also discuss the implications of ILUC for designing policies that promote biofuels and seek to reduce GHG emissions. In a first-best setting, a global carbon tax is needed to set both DLUC and ILUC emissions to their optimal levels. However, it is unclear whether unilateral GHG mitigation policies, even if they penalize the ILUC-related emissions, would increase social welfare and lead to optimal emission levels. In the absence of a global carbon tax, incentivizing sustainable land use practices through certification standards, government regulations and market-based pressures may be a viable option for reducing ILUC.

  10. Alternative Fuels Data Center: Tools

    Science.gov Websites

    Calculator Compare cost of ownership and emissions for most vehicle models. mobile Petroleum Reduction ROI and payback period for natural gas vehicles and infrastructure. AFLEET Tool Calculate a fleet's , hydrogen, or fuel cell infrastructure. GREET Fleet Footprint Calculator Calculate your fleet's petroleum

  11. Energy survey study and report of hospitals in Chicago: South Suburban Hospital: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-08-01

    This study is part of a three-phased demonstration project to reduce energy consumption in hospitals through practical life-cycle/cost-effective modifications and alteration. Funds for the demonstration project are provided by the American Hospital Association (AHA), the Department of Energy (DOE), and the Department of Health and Human Services (DHHS). A thorough study and evaluation of all building systems is made to identify opportunities for reduction in energy consumption and to determine the most cost effective approaches to energy conservation. The primary objective of the study is to investigate and analyze energy usage of the facility and to identify all life cycle,more » cost-effective changes required to effect a reduction in energy consumption. For the purpose of economic evaluation of the energy conservation projects identified, life-cycle cost and simple payback periods are used. Energy conservation measures with simple payback periods exceeding five years were dismissed from further detailed study.« less

  12. An economic analysis of a safe resident handling program in nursing homes.

    PubMed

    Lahiri, Supriya; Latif, Saira; Punnett, Laura

    2013-04-01

    Occupational injuries, especially back problems related to resident handling, are common in nursing home employees and their prevention may require substantial up-front investment. This study evaluated the economics of a safe resident handling program (SRHP), in a large chain of skilled nursing facilities, from the corporation's perspective. The company provided data on program costs, compensation claims, and turnover rates (2003-2009). Workers' compensation and turnover costs before and after the intervention were compared against investment costs using the "net-cost model." Among 110 centers, the overall benefit-to-cost ratio was 1.7-3.09 and the payback period was 1.98-1.06 year (using alternative turnover cost estimates). The average annualized net savings per bed for the 110 centers (using company based turnover cost estimates) was $143, with a 95% confidence interval of $22-$264. This was very similar to the average annualized net savings per full time equivalent (FTE) staff member, which was $165 (95% confidence interval $22-$308). However, at 49 centers costs exceeded benefits. Decreased costs of worker injury compensation claims and turnover appear at least partially attributable to the SRHP. Future research should examine center-specific factors that enhance program success, and improve measures of turnover costs and healthcare productivity. Copyright © 2012 Wiley Periodicals, Inc.

  13. Financial Analysis: A Review of the Methods and Their Application to Employee Training. Training and Development Research Center Project Number Nine.

    ERIC Educational Resources Information Center

    Mosier, Nancy R.

    Financial analysis techniques are tools that help managers make sound financial decisions that contribute to general corporate objectives. A literature review reveals that the most commonly used financial analysis techniques are payback time, average rate of return, present value or present worth, and internal rate of return. Despite the success…

  14. 10 CFR 455.63 - Cost-effectiveness testing.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) The simple payback period of each energy conservation measure (except measures to shift demand, or...), by the estimated annual cost savings accruing from the measure (adjusted for demand charges), as... non-renewable fuels displaced less the annual cost of the renewable fuel, if any, and the annual cost...

  15. 10 CFR 455.63 - Cost-effectiveness testing.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) The simple payback period of each energy conservation measure (except measures to shift demand, or...), by the estimated annual cost savings accruing from the measure (adjusted for demand charges), as... non-renewable fuels displaced less the annual cost of the renewable fuel, if any, and the annual cost...

  16. Modeling Stochastic Energy and Water Consumption to Manage Residential Water Uses

    NASA Astrophysics Data System (ADS)

    Abdallah, A. M.; Rosenberg, D. E.; Water; Energy Conservation

    2011-12-01

    Water energy linkages have received growing attention from the water and energy utilities as utilities recognize that collaborative efforts can implement more effective conservation and efficiency improvement programs at lower cost with less effort. To date, limited energy-water household data has allowed only deterministic analysis for average, representative households and required coarse assumptions - like the water heater (the primary energy use in a home apart from heating and cooling) be a single end use. Here, we use recent available disaggregated hot and cold water household end-use data to estimate water and energy consumption for toilet, shower, faucet, dishwasher, laundry machine, leaks, and other household uses and savings from appliance retrofits. The disaggregated hot water and bulk water end-use data was previously collected by the USEPA for 96 single family households in Seattle WA and Oakland CA, and Tampa FL between the period from 2000 and 2003 for two weeks before and four weeks after each household was retrofitted with water efficient appliances. Using the disaggregated data, we developed a stochastic model that represents factors that influence water use for each appliance: behavioral (use frequency and duration), demographical (household size), and technological (use volume or flowrate). We also include stochastic factors that govern energy to heat hot water: hot water fraction (percentage of hot water volume to total water volume used in a certain end-use event), heater water intake and dispense temperatures, and energy source for the heater (gas, electric, etc). From the empirical household end-use data, we derive stochastic probability distributions for each water and energy factor where each distribution represents the range and likelihood of values that the factor may take. The uncertainty of the stochastic water and energy factors is propagated using Monte Carlo simulations to calculate the composite probability distribution for water and energy use, potential savings, and payback periods to install efficient water end-use appliances and fixtures. Stochastic model results show the distributions among households for (i) water end-use, (ii) energy consumed to use water, and (iii) financial payback periods. Compared to deterministic analysis, stochastic modeling results show that hot water fractions for appliances follow normal distributions with high standard deviation and reveal pronounced variations among households that significantly affect energy savings and payback period estimates. These distributions provide an important tool to select and size water conservation programs to simultaneously meet both water and energy conservation goals. They also provide a way to identify and target a small fraction of customers with potential to save large water volumes and energy from appliance retrofits. Future work will embed this household scale stochastic model in city-scale models to identify win-win water management opportunities where households save money by conserving water and energy while cities avoid costs, downsize, or delay infrastructure development.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Geet, Otto

    NREL has developed a methodology to prioritize which data center cooling systems could be upgraded for better efficiency based on estimated cost savings and economics. The best efficiency results are in cool or dry climates where 'free' economizer or evaporative cooling can provide most of the data center cooling. Locations with a high cost of energy and facilities with high power usage effectiveness (PUE) are also good candidates for data center cooling system upgrades. In one case study of a major cable provider's data centers, most of the sites studied had opportunities for cost-effective cooling system upgrades with payback periodmore » of 5 years or less. If the cable provider invested in all opportunities for upgrades with payback periods of less than 15 years, it could save 27% on annual energy costs.« less

  18. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  19. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  20. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  1. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  2. 42 CFR 66.110 - Service, payback, and recovery requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Service, payback, and recovery requirements. 66.110 Section 66.110 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.110 Service, payback, and recovery...

  3. 34 CFR 263.9 - When does payback begin?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false When does payback begin? 263.9 Section 263.9 Education Regulations of the Offices of the Department of Education OFFICE OF ELEMENTARY AND SECONDARY EDUCATION, DEPARTMENT OF EDUCATION INDIAN EDUCATION DISCRETIONARY GRANT PROGRAMS Professional Development Program § 263.9 When does payback begin? (a) For...

  4. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  5. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  6. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  7. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  8. 10 CFR 436.23 - Estimated simple payback time.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Methodology and Procedures for Life Cycle Cost Analyses § 436.23 Estimated simple payback time. The estimated simple payback time is the number of years required for the cumulative value of energy or water cost savings less future non-fuel or non-water costs to equal the investment costs of the building energy or...

  9. Three empirical essays on consumer behavior related to climate change and energy

    NASA Astrophysics Data System (ADS)

    Jacobsen, Grant Douglas

    This dissertation consists of three essays. All of the chapters address a topic in the area of household and consumer behavior related to climate change or energy. The first chapter is titled "The Al Gore Effect: An Inconvenient Truth and Voluntary Carbon Offsets". This chapter examines the relationship between climate change awareness and household behavior by testing whether Al Gore's documentary An Inconvenient Truth caused an increase in the purchase of voluntary carbon offsets. The analysis shows that in the two months following the film's release, zip codes within a 10-mile radius of a zip code where the film was shown experienced a 50 percent relative increase in the purchase of voluntary carbon offsets. The second chapter is titled "Are Building Codes Effective at Saving Energy? Evidence from Residential Billing Data in Florida". The analysis shows that Florida's energy-code change that took effect in 2002 is associated with a 4-percent decrease in electricity consumption and a 6-percent decrease in natural-gas consumption in Gainesville, FL. The estimated private payback period for the average residence is 6.4 years and the social payback period ranges between 3.5 and 5.3 years. The third chapter in this dissertation is titled "Do Environmental Offsets Increase Demand for Dirty Goods? Evidence from Residential Electricity Demand". This study evaluates the relationship between green products and existing patterns of consumer behavior by examining the relationship between household enrollment in a green electricity program and consumption of residential electricity. The results suggest there are two different types of green consumers. One type makes a small monthly donation and partially views the donation as a substitute for a previously existing pattern of green behavior, in this case, energy conservation. The other type makes a larger monthly donation and views the donation as a way to make strictly additional improvements in environmental quality.

  10. 24 CFR 965.304 - Order of funding.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Order of funding. 965.304 Section....304 Order of funding. Within the funds available to a PHA, energy conservation measures should be accomplished with the shortest pay-back periods funded first. A PHA may make adjustments to this funding order...

  11. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phadke, Amol; Shah, Nihar; Abhyankar, Nikit

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robustmore » over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment« less

  12. Energetic-environmental-economic assessment of the biogas system with three utilization pathways: Combined heat and power, biomethane and fuel cell.

    PubMed

    Wu, Bin; Zhang, Xiangping; Shang, Dawei; Bao, Di; Zhang, Suojiang; Zheng, Tao

    2016-08-01

    A typical biogas system with three utilization pathways, i.e., biogas upgrading, biogas combined heat and power (CHP), biogas solid oxide fuel cells (SOFCs) were designed. It was assessed from the viewpoint of energy, environment and economy by using energy efficiency, green degree and net present value index respectively. The assessment considered the trade-off relationships among these indexes, which is more comprehensive than previous systematic evaluation work only included single or two of the pathway(s) by using one or two of the index(es). Assessment results indicated that biogas upgrading pathway has the highest systematic energy efficiency (46.5%) and shortest payback period (8.9year) with the green degree production is the lowest (9.29gd/day). While for biogas SOFC pathway, although the green degree production is the highest (21.77gd/day), the payback period is longer (14.5year) and the energy efficiency is 13.6% lower than the biogas upgrading pathway. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Biogas - the calculable energy

    NASA Astrophysics Data System (ADS)

    Kith, Károly; Nagy, Orsolya; Balla, Zoltán; Tamás, András

    2015-04-01

    EU actions against climate change are rising energy prices, both have emphasized the use of renewable energy,increase investments and energy efficiency. A number of objectives formulated in the EC decree no. 29/2009 by 2020. This document is based on the share of renewable energies in energy consumption should be increased to 20% (EC, 2009). The EU average is 20% but the share of renewables vary from one member state to another. In Hungary in 2020, 14.65% renewable energy share is planned to be achieved. According to the latest Eurostat data, the share of renewable energy in energy consumption of the EU average was 14.1%, while in Hungary, this share was 9.6% in 2012. (EUROSTAT, 2014). The use of renewable energy plant level is influenced by several factors. The most important of these is the cost savings and efficiency gains. Hungarian investments in renewable energy production usually have high associated costs and the payback period is substantially more than five years, depending on the support rate. For example, the payback period is also influenced by the green electricity generated feed prices, which is one of the lowest in Hungary compared the Member States of the European Union. Consequently, it is important to increase the production of green energy. Nowadays, predictable biogas energy is an outstanding type of decentralized energy production. It follows directly that agricultural by-products can be used to produce energy and they also create jobs by the construction of a biogas plant. It is important to dispose of and destroy hazardous and noxious substances in energy production. It follows from this that the construction of biogas plants have a positive impact, in addition to green energy which is prepared to reduce the load on the environment. The production of biogas and green electricity is one of the most environment friendly forms of energy production. Biogas production also has other important ecological effects, such as the substitution of fertilizers, reducing its use in agriculture, which protects groundwater and surface water conditions and reduces the amount of greenhouse gases in the atmosphere. In the future more emphasis should be given to increase the effectiveness of existing technologies and other types of innovation could be expanded in energy production. It can be concluded that green energy investments can be rewarding if accurate planning is carried out before the investment.

  14. Methods for assessing the energy-saving efficiency of industrial symbiosis in industrial parks.

    PubMed

    Li, Wenfeng; Cui, Zhaojie; Han, Feng

    2015-01-01

    The available energy resources are being depleted worldwide. Industrial symbiosis (IS) provides a promising approach for increasing the efficiency of energy utilization, with numerous studies reporting the superiority of this technology. However, studies quantifying the energy-saving efficiency of IS remain insufficient. This paper proposes an index system for the quantitative evaluation of the energy-saving efficiency of IS. Both energy-saving and financial indexes were selected, the former include the IS energy-saving index, the contribution rate of energy saved through IS, fractional energy savings, and cut rate of energy consumption per total output value; and the latter include the IS investment payback period, IS input-output ratio, net present value (NPV), and internal rate of return (IRR) of IS. The proposed methods were applied to a case study on the XF Industrial Park (XF IP), in the city of Liaocheng in Shandong Province of China. Three energy-saving channels using IS were found in the XF IP: (a) utilizing the energy of high-temperature materials among industrial processes, (b) recovering waste heat and steam between different processes, and (c) saving energy by sharing infrastructures. The results showed that the energy efficiency index of IS was 0.326, accounting for 34.6% of the comprehensive energy-saving index in 2011, and the fractional energy-savings were 12.42%. The index of energy consumption per total industrial output value varied from 90.9 tce/MRMB to 51.6 tce/MRMB. Thus, the cut rate of energy consumption per total industrial output value was 43.42%. The average values of the IS input-output ratio was 406.2 RMB/tce, 57.2% lower than the price of standard coal. Static investment payback period in the XF IP was 8.5 months, indicating that the XF IP began to earn profit 8.5 months after the construction of all IS modes. The NVP and IRR of each IS mode in the XF IP were greater than zero, with average values equal to 1,789.96 MRMB and 140.96%, respectively. The computation result for each indicator revealed that IS could lead to the use of energy with high efficiency and lighten the financial burden of enterprises in the XF IP. And the proposed index system may help IPs and EIPs to make strategic decisions when designing IS modes.

  15. Payback as an investment criterion for sawmill improvement projects

    Treesearch

    G. B. Harpole

    1983-01-01

    Methods other than presented here should be used to assess projects for likely return on investment; but, payback is simple to calculate and can be used for calculations that will indicate the relative attractiveness of alternative improvement projects. This paper illustrates how payback ratios are calculated, how they can be used to rank alternative improvement...

  16. Development of an in-house hospital information system in a hospital in Pakistan.

    PubMed

    Sultan, Faisal; Aziz, Muhammad Tahir; Khokhar, Idrees; Qadri, Hussain; Abbas, Manzar; Mukhtar, Amir; Manzoor, Waqar; Yusuf, Muhammed Aasim

    2014-03-01

    To review our experience of development and implementation of an electronic hospital information system, its costs and return on investment as well as incorporation of some key quality standards. Cost and saving trends of the project were calculated using different tools including project expense, cost saving through cessation of printing radiology films and paper. Net present value with payback period was utilized to evaluate the efficiency of the health information systems. Qualitative improvements in different healthcare functions were also analyzed. The total saving of the project was approximately US$ 5.1 million with net saving of US$ 3.5 million for the period from 2001 to 2011. The net present value of the project is US$ 3.2 million with a payback period of 3.4 years. Electronic hospital information systems and health records hold the potential to be useful tools for quality improvement and error reduction. Adoption of such systems, however, has been slow and erratic, worldwide. Utilizing the concept of net present value, development of such a system may be financially viable for some institutions. Instead of simply replacing paper, these systems may also be used to improve information management and improve quality of patient care. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Development of an Enhanced Payback Function for the Superior Energy Performance Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Therkelsen, Peter; Rao, Prakash; McKane, Aimee

    2015-08-03

    The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This papermore » analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.« less

  18. Demonstration Assessment of Light Emitting Diode (LED) Walkway Lighting at the Federal Aviation Administration William J. Hughes Technical Center, in Atlantic City, New Jersey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    This report documents the results of a collaborative project to demonstrate a solid state lighting (SSL) general illumination product in an outdoor area walkway application. In the project, six light-emitting diode (LED) luminaires were installed to replace six existing high pressure sodium (HPS) luminaires mounted on 14-foot poles on a set of exterior walkways and stairs at the Federal Aviation Administration (FAA) William J. Hughes Technical Center in Atlantic City, New Jersey, during December, 2007. The effort was a U.S. Department of Energy (DOE) SSL Technology Gateway Demonstration that involved a collaborative teaming agreement between DOE, FAA and Ruud Lightingmore » (and their wholly owned division, Beta LED). Pre- and post-installation power and illumination measurements were taken and used in calculations of energy savings and related economic payback, while personnel impacted by the new lights were provided questionnaires to gauge their perceptions and feedback. The SSL product demonstrated energy savings of over 25% while maintaining illuminance levels and improving illuminance uniformity. PNNL's economic analysis yielded a variety of potential payback results depending on the assumptions used. In the best case, replacing HPS with the LED luminaire can yield a payback as low as 3 years. The new lamps were quite popular with the affected personnel, who gave the lighting an average score of 4.46 out of 5 for improvement.« less

  19. 78 FR 13566 - Energy Conservation Program for High-Intensity Discharge Lamps: Public Meeting and Availability...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... Prices C. Energy Use Analysis D. Life-Cycle Cost and Payback Period Analyses E. National Impact Analysis... projected energy prices and installed stock in each year. DOE calculates annual equipment expenditures by... DEPARTMENT OF ENERGY 10 CFR Part 431 [Docket No. EERE-2010-BT-STD-0043] RIN 1904-AC36 Energy...

  20. Army Reserve 63d RSC Achieves 85% Savings in Parking Lot Lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Case study describes how the Army Reserve 63d Regional Support Command (RSC) achieved 85% energy savings and $4,000 per year in cost savings by replacing 12 old light fixtures with light-emitting diode fixtures in the military equipment parking area. This project was part of a camp-wide parking lighting retrofit which, on average, delivered 78% energy savings and a simple payback of 4.4 years.

  1. Sand Filter Technology

    DTIC Science & Technology

    2016-08-01

    Approved for public release: distribution unlimited TDS-NAVFAC-EXWC-PW-1604 Aug 2016 Sand Filter Technology This report summarizes the...findings from a demonstration of sand filter technology to determine whether the technology will save energy with a simple payback within the...EXWC) performed the evaluation at the Naval Air Station Lemoore, CA. The two year evaluation period began with one year of sand filter operation

  2. DRIVE: Drive-Cycle Rapid Investigation, Visualization, and Evaluation

    Science.gov Websites

    specialized statistical clustering methods. The duration of these representative drive cycles, which aim to , DRIVE can benefit a variety of users. For example: Fleet managers can use the tool to make educated investment decisions by determining, in advance, the payback period for a given technology. Vehicle

  3. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Nihar; Abhyankar, Nikit; Park, Won Young

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report.more » The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.« less

  4. Predictors of return rate discrimination in slot machine play.

    PubMed

    Coates, Ewan; Blaszczynski, Alex

    2014-09-01

    The purpose of this study was to investigate the extent to which accurate estimates of payback percentages and volatility combined with prior learning, enabled players to successfully discriminate between multi-line/multi-credit slot machines that provided differing rates of reinforcement. The aim was to determine if the capacity to discriminate structural characteristics of gaming machines influenced player choices in selecting 'favourite' slot machines. Slot machine gambling history, gambling beliefs and knowledge, impulsivity, illusions of control, and problem solving style were assessed in a sample of 48 first year undergraduate psychology students. Participants were subsequently exposed to a choice paradigm where they could freely select to play either of two concurrently presented PC-simulated slot machines programmed to randomly differ in expected player return rates (payback percentage) and win frequency (volatility). Results suggest that prior learning and cognitions (particularly gambler's fallacy) but not payback, were major contributors to the ability of a player to discriminate volatility between slot machines. Participants displayed a general tendency to discriminate payback, but counter-intuitively placed more bets on the slot machine with lower payback percentage rates.

  5. Wind power as an electrical energy source in Illinois

    NASA Astrophysics Data System (ADS)

    Wendland, W. M.

    1982-03-01

    A preliminary estimate of the total wind power available in Illinois was made using available historical data, and projections of cost savings due to the presence of wind-generated electricity were attempted. Wind data at 10 m height were considered from nine different sites in the state, with three years data nominally being included. Wind-speed frequency histograms were developed for day and night periods, using a power law function to extrapolate the 10 m readings to 20 m. Wind speeds over the whole state were found to average over 8 mph, the cut-in point for most wind turbines, for from 40-63% of the time. A maximum of 75% run-time was determined for daylight hours in April-May. A reference 1.8 kW windpowered generator was used in annual demand projections for a reference one family home, using the frequency histograms. The small generator was projected to fulfill from 25-53% of the annual load, and, based on various cost assumptions, exhibited paybacks taking from 14-27 yr.

  6. A Cost to Benefit Analysis of a Next Generation Electric Power Distribution System

    NASA Astrophysics Data System (ADS)

    Raman, Apurva

    This thesis provides a cost to benefit analysis of the proposed next generation of distribution systems- the Future Renewable Electric Energy Distribution Management (FREEDM) system. With the increasing penetration of renewable energy sources onto the grid, it becomes necessary to have an infrastructure that allows for easy integration of these resources coupled with features like enhanced reliability of the system and fast protection from faults. The Solid State Transformer (SST) and the Fault Isolation Device (FID) make for the core of the FREEDM system and have huge investment costs. Some key features of the FREEDM system include improved power flow control, compact design and unity power factor operation. Customers may observe a reduction in the electricity bill by a certain fraction for using renewable sources of generation. There is also a possibility of huge subsidies given to encourage use of renewable energy. This thesis is an attempt to quantify the benefits offered by the FREEDM system in monetary terms and to calculate the time in years required to gain a return on investments made. The elevated cost of FIDs needs to be justified by the advantages they offer. The result of different rates of interest and how they influence the payback period is also studied. The payback periods calculated are observed for viability. A comparison is made between the active power losses on a certain distribution feeder that makes use of distribution level magnetic transformers versus one that makes use of SSTs. The reduction in the annual active power losses in the case of the feeder using SSTs is translated onto annual savings in terms of cost when compared to the conventional case with magnetic transformers. Since the FREEDM system encourages operation at unity power factor, the need for installing capacitor banks for improving the power factor is eliminated and this reflects in savings in terms of cost. The FREEDM system offers enhanced reliability when compared to a conventional system. The payback periods observed support the concept of introducing the FREEDM system.

  7. How can payback from health services research be assessed?

    PubMed

    Buxton, M; Hanney, S

    1996-01-01

    Throughout the world there is a growing recognition that health care should be research-led. This strengthens the requirement for expenditure on health services research to be justified by demonstrating the benefits it produces. However, payback from health research and development is a complex concept and little used term. Five main categories of payback can be identified: knowledge; research benefits; political and administrative benefits; health sector benefits; and broader economic benefits. Various models of research utilization together with previous assessments of payback from research helped in the development of a new conceptual model of how and where payback may occur. The model combines an input-output perspective with an examination of the permeable interfaces between research and its environment. The model characterizes research projects in terms of Inputs, Processes, and Primary Outputs. The last consist of knowledge and research benefits. There are two interfaces between the project and its environment. The first (Project Specification, Selection and Commissioning) is the link with Research Needs Assessment. The second (Dissemination) should lead to Secondary Outputs (which are policy or administrative decisions), and usually Applications (which take the form of behavioural changes), from which Impacts or Final Outcomes result. It is at this final stage that health and wider economic benefits can be measured. A series of case studies were used to assess the feasibility both of applying the model and the payback categorization. The paper draws various conclusions from the case studies and identifies a range of issues for further work.

  8. Essential Power Systems Workshop - OEM Perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bill Gouse

    2001-12-12

    In California, idling is largely done for climate control. This suggests that climate control devices alone could be used to reduce idling. Line-haul truck drivers surveyed require an average of 4-6 kW of power for a stereo, CB radio, light, refrigerator, and climate control found in the average truck. More power may likely be necessary for peak power demands. The amount of time line-haul trucks reported to have stopped is between 25 and 30 hours per week. It was not possible to accurately determine from the pilot survey the location, purpose, and duration of idling. Consulting driver logs or electronicallymore » monitoring trucks could yield more accurate data, including seasonal and geographic differences. Truck drivers were receptive to idling alternatives. Two-thirds of truck drivers surveyed support a program to reduce idling. Two-thirds of drivers reported they would purchase idling reduction technologies if the technology yielded a payback period of two years or less. Willingness to purchase auxiliary power units appears to be higher for owner-operators than for company drivers. With a 2-year payback period, 82% of owner- operators would be willing to buy an idle- reducing device, while 63% of company drivers thought their company would do the same. Contact with companies is necessary to discern whether this difference between owner- operators and companies is true or simply due to the perception of the company drivers. Truck stops appear to be a much more attractive option for electrification than rest areas by a 48% to 21% margin. Much of this discrepancy may be due to perceived safety problems with rest areas. This survey did not properly differentiate between using these areas for breaks or overnight. The next, full survey will quantify where the truck drivers are staying overnight, where they go for breaks, and the duration of time they spend at each place. The nationwide survey, which is in progress, will indicate how applicable the results are to the US in general. In addition to the survey, we believe data loggers and focus groups will be necessary to collect the idling duration and location data necessary to compare auxiliary power units to truck stop electrification. Focus groups are recommended to better understand the driver response to APUs and electrification. The appearance and perception of the new systems will need further clarification, which could be accomplished with a demonstration for truck drivers.« less

  9. Solar breeder: Energy payback time for silicon photovoltaic systems

    NASA Technical Reports Server (NTRS)

    Lindmayer, J.

    1977-01-01

    The energy expenditures of the prevailing manufacturing technology of terrestrial photovoltaic cells and panels were evaluated, including silicon reduction, silicon refinement, crystal growth, cell processing and panel building. Energy expenditures include direct energy, indirect energy, and energy in the form of equipment and overhead expenses. Payback times were development using a conventional solar cell as a test vehicle which allows for the comparison of its energy generating capability with the energies expended during the production process. It was found that the energy payback time for a typical solar panel produced by the prevailing technology is 6.4 years. Furthermore, this value drops to 3.8 years under more favorable conditions. Moreover, since the major energy use reductions in terrestrial manufacturing have occurred in cell processing, this payback time directly illustrates the areas where major future energy reductions can be made -- silicon refinement, crystal growth, and panel building.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sargent, S.A.

    Apple pomace or presscake, was evaluated for suitability as a boiler feedstock for Michigan firms processing apple juice. Based upon the physical and chemical characteristics of pomace, handling/direct combustion systems were selected to conform with operating parameters typical of the industry. Fresh pomace flow rates of 29,030 and 88,998 kg/day (64,000 and 194,000 lb/day) were considered as representative of small and large processors, respectively, and the material was assumed to be dried to 15% moisture content (wet basis) prior to storage and combustion. Boilers utilizing pile-burning, fluidized-bed-combustion, and suspension-firing technologies were sized for each flow rate, resulting in energy productionmore » of 2930 and 8790 kW (10 and 30 million Btu/h), respectively. A life-cycle cost analysis was performed giving Average Annual Costs for the three handling/combustion system combinations (based on the Uniform Capital Recovery factor). An investment loan at 16% interest with a 5-year payback period was assumed. The break-even period for annual costs was calculated by anticipated savings incurred through reduction of fossil-fuel costs during a 5-month processing season. Large processors, producing more than 88,998 kg pomace/day, could economically convert to a suspension-fired system substituting for fuel oil, with break-even occurring after 4 months of operation of pomace per year. Small processors, producing less than 29,030 kg/day, could not currently convert to pomace combustion systems given these economic circumstances. A doubling of electrical-utility costs and changes in interest rates from 10 to 20% per year had only slight effects on the recovery of Average Annual Costs. Increases in fossil-fuel prices and the necessity to pay for pomace disposal reduced the cost-recovery period for all systems, making some systems feasible for small processors. 39 references, 13 figures, 10 tables.« less

  11. An Economic Analysis of a Safe Resident Handling Program in Nursing Homes

    PubMed Central

    Lahiri, Supriya; Latif, Saira; Punnett, Laura

    2018-01-01

    Background Occupational injuries, especially back problems related to resident handling, are common in nursing home employees and their prevention may require substantial up-front investment. This study evaluated the economics of a safe resident handling program (SRHP), in a large chain of skilled nursing facilities, from the corporation's perspective. Methods The company provided data on program costs, compensation claims, and turnover rates (2003-2009). Workers' compensation and turnover costs before and after the intervention were compared against investment costs using the “net-cost model”. Results Among 110 centers, the overall benefit-to-cost ratio was 1.7–3.09 and the payback period was 1.98–1.06 year (using alternative turnover cost estimates). The average annualized net savings per bed for the 110 centers (using company based turnover cost estimates) was $143, with a 95% confidence interval of $22–$264. This was very similar to the average annualized net savings per full time equivalent (FTE) staff member, which was $165 (95% confidence interval $22–$308). However, at 49 centers costs exceeded benefits. Conclusions Decreased costs of worker injury compensation claims and turnover appear at least partially attributable to the SRHP. Future research should examine center-specific factors that enhance program success, and improve measures of turnover costs and healthcare productivity. PMID:23203729

  12. Fresh air indoors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kull, K.

    1988-09-01

    This article describes and compares ventilation systems for the control of indoor air pollution in residential housing. These include: local exhaust fans, whole-house fans, central exhaust with wall ports, and heat-recovery central ventilation (HRV). HRV's have a higher initial cost than the other systems but they are the only ones that save energy. Homeowners are given guidelines for choosing the system best suited for their homes in terms of efficiency and payback period.

  13. Managerial preferences in relation to financial indicators regarding the mitigation of global change.

    PubMed

    Maroušek, Josef; Hašková, Simona; Zeman, Robert; Vaníčková, Radka

    2015-02-01

    Biochar is a soil-improving substrate made from phytomass pyrolysis. In Southeast Asia, its application decreases due to the long-term growth of biochar cost and thus caused further prolongation of the payback period. In the Euro-American civilization the biochar application is already almost forgotten once it has been much earlier recognized that the crop yields can be increased much faster with higher doses of nutrients and other agrochemicals. The payback period can be expected in decades. Such a long-time investment into soil fertility raises also many ethical questions. The final decision combines issues of social responsibility, risk and other financial indicators as well as personal preferences and more. The attitudes of Western and Central European decision makers in the agriculture business segment were analyzed on the basis of electronic questionnaire survey and a subsequent interview through their local unions. According to the data, most of them did not know about the possibilities of a more environmentally friendly approach to soil enhancement based on the addition of a fertilizer in the form of biochar. Among others, the collected data also shows that the decision makers from Western Europe have a much different ethical approach to the land and financial indicators than the Central Europeans.

  14. Optimized MBR for greywater reuse systems in hotel facilities.

    PubMed

    Atanasova, Natasa; Dalmau, Montserrat; Comas, Joaquim; Poch, Manel; Rodriguez-Roda, Ignasi; Buttiglieri, Gianluigi

    2017-05-15

    Greywater is an important alternative water source, particularly in semi-arid, touristic areas, where the biggest water demand is usually in the dry period. By using this source wisely, tourist facilities can substantially reduce the pressure to scarce water resources. In densely urbanized touristic areas, where space has high value, compact solutions such as MBR based greywater reuse systems appear very appropriate. This research focuses on technical and economical evaluation of such solution by implementing a pilot MBR to a hotel with separated grey water. The pilot was operated for 6 months, with thorough characterisation of the GW performed, its operation was monitored and its energy consumption was optimized by applying a control system for the air scour. Based on the pilot operation a design and economic model was set to estimate the feasibility (CAPEX, OPEX, payback period of investment) of appropriate scales of MBR based GW systems, including separation of GW, MBR technology, clean water storage and disinfection. The model takes into account water and energy prices in Spain and a planning period of 20 years. The results demonstrated an excellent performance in terms of effluent quality, while the energy demand for air-scour was reduced by up to 35.2%, compared to the manufacturer recommendations. Economical evaluation of the entire MBR based GW reuse system shows its feasibility for sizes already at 5 m 3 /day (60 PE). The payback period of the investment for hotels like the demonstration hotel, treating 30 m 3 /day is 3 years. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Round-bale feeder design affects hay waste and economics during horse feeding.

    PubMed

    Martinson, K; Wilson, J; Cleary, K; Lazarus, W; Thomas, W; Hathaway, M

    2012-03-01

    Many horse owners find round bales convenient, less labor intensive, and more affordable than other hay types, but report an inability to control horse BW gain and excessive hay waste. The objectives were to compare hay waste, hay intake, and payback of 9 round-bale feeders and a no-feeder control when used during horse feeding. Nine round-bale feeders were tested: Cinch Net, Cone, Covered Cradle, Hayhut, Hay Sleigh, Ring, Tombstone, Tombstone Saver, and Waste Less. Each feeder design was placed on the ground in a dirt paddock. Five groups of 5 horses were fed in rotation for a 4-d period with each feeder. Every fourth day, groups were rotated among paddocks and a new round bale was placed in each feeder. In the 5 paddocks used, 5 feeders were installed for d 1 through 20, and the remaining 4 feeders and no-feeder control were installed for d 21 through 40. Groups of horses were sequentially assigned to feeders using two 5 × 5 Latin squares, the first for d 1 through 20, the second for d 21 through 40. Horse groups of similar age, BW, breed, and sex were formed from 25 Quarter Horse and Thoroughbred geldings and open mares (means: 11 yr; 541 kg of BW). Hay on the ground surrounding the feeder was collected daily, dried, and weighed. The total amount of hay removed around each feeder for a 4-d period was considered waste. Dry matter intake was estimated as the difference between hay disappearance and waste. Number of months for the reduction in waste to repay feeder cost (payback) were calculated using hay valued at $110/t, and improved feeder efficiency over the control. Feeder design did not affect hay intake (P > 0.05); all feeders resulted in an estimated hay intake of 2.0 to 2.4% BW; the no-feeder control resulted in a reduced intake of 1.3% BW (P = 0.001). Mean percentage of hay waste differed among feeders (P < 0.001): Waste Less, 5%; Cinch Net, 6%; Hayhut, 9%; Covered Cradle, 11%; Tombstone Saver, 13%; Tombstone, Cone, and Ring, 19%; Hay Sleigh, 33%; and no-feeder control, 57%. Feeder design also affected payback (P < 0.01). The Cinch Net paid for itself in less than 1 mo; Tombstone and Ring, 2 mo; Hayhut and Tombstone Saver, 4 mo; Hay Sleigh, 5 mo; Waste Less, 8 mo; Cone, 9 mo; and Covered Cradle, 20 mo. Round-bale feeder design affected hay waste and payback, but not estimated hay intake or BW change during horse feeding.

  16. On Adaptive Extended Different Life Cycle of Product Design Strategy

    NASA Astrophysics Data System (ADS)

    Wenwen, Jiang; Zhibin, Xie

    The article uses research ways of following the whole lifespan of product and enterprise's development course to research strategy of company's product design and development. It announces enterprises of different nature, enterprises at different developing stage will adopt different mode strategy. It also announces close causality between development course of company and central technology and product. The result indicated in different developing stages such as company development period, crisis predicament period, lasting steadies period, improving by payback period, issues steadies secondary period, declining go and live period, enterprise should pursue different mode product tactics of research and development such as shrinking strategy, consolidating strategy, innovation keeping forging ahead strategy. Enterprise should break regular management mode to introduce different research and development mode to promote enterprise's competitiveness effectively.

  17. 34 CFR 263.9 - When does payback begin?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF EDUCATION INDIAN EDUCATION DISCRETIONARY GRANT PROGRAMS Professional Development Program § 263... Professional Development program, payback shall begin within six months from the date of completion of the training. (b) For participants who do not complete their training under the Professional Development...

  18. An analysis of switching and non-switching slot machine player behaviour.

    PubMed

    Coates, Ewan; Blaszczynski, Alex

    2013-12-01

    Learning theory predicts that, given the repeated choice to bet between two concurrently available slot machines, gamblers will learn to bet more money on the machine with higher expected return (payback percentage) or higher win probability per spin (volatility). The purpose of this study was to investigate whether this occurs when the two machines vary orthogonally on payback percentage and volatility. The sample comprised 52 first year psychology students (mean age = 20.3 years, 20 females, 32 males) who had played a gaming machine at least once in the previous 12 months. Participants were administered a battery of questionnaires designed to assess level of knowledge on the characteristics and operation of poker machines, frequency of poker machine play in the past 12 months, personality traits of impulsivity and capacity for cognitive reflection, and gambling beliefs. For the experimental task, participants were instructed to play on two PC-simulated electronic gaming machines (EGMs or slot machines) that differed on payback percentage and volatility, with the option of freely switching between EGMs after a practice phase. Results indicated that participants were able to easily discriminate between machines and manifested a preference to play machines offering higher payback or volatility. These findings diverged from previous findings of no preference for play on higher payback/volatility machines, potentially due to of the current study's absence of the option to make multi-line and multi-credit bets. It was concluded that return rate parameters like payback percentage and volatility strongly influenced slot machine preference in the absence of betting options like multi-line bets, though more research is needed to determine the effects of such betting options on player distribution of money between multiple EGMs.

  19. A cost–benefit analysis of acclimation to low irradiance in tropical rainforest tree seedlings: leaf life span and payback time for leaf deployment

    PubMed Central

    Coste, Sabrina; Roggy, Jean-Christophe; Schimann, Heidy; Epron, Daniel; Dreyer, Erwin

    2011-01-01

    The maintenance in the long run of a positive carbon balance under very low irradiance is a prerequisite for survival of tree seedlings below the canopy or in small gaps in a tropical rainforest. To provide a quantitative basis for this assumption, experiments were carried out to determine whether construction cost (CC) and payback time for leaves and support structures, as well as leaf life span (i) differ among species and (ii) display an irradiance-elicited plasticity. Experiments were also conducted to determine whether leaf life span correlates to CC and payback time and is close to the optimal longevity derived from an optimization model. Saplings from 13 tropical tree species were grown under three levels of irradiance. Specific-CC was computed, as well as CC scaled to leaf area at the metamer level. Photosynthesis was recorded over the leaf life span. Payback time was derived from CC and a simple photosynthesis model. Specific-CC displayed only little interspecific variability and irradiance-elicited plasticity, in contrast to CC scaled to leaf area. Leaf life span ranged from 4 months to >26 months among species, and was longest in seedlings grown under lowest irradiance. It was always much longer than payback time, even under the lowest irradiance. Leaves were shed when their photosynthesis had reached very low values, in contrast to what was predicted by an optimality model. The species ranking for the different traits was stable across irradiance treatments. The two pioneer species always displayed the smallest CC, leaf life span, and payback time. All species displayed a similar large irradiance-elicited plasticity. PMID:21511904

  20. Five-city economics of a solar hot-water-system

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report projects energy savings and system costs for five sites using analysis of actual solar energy installation performance in Togus, Maine. Maine system supplies 75 percent of hot water needed for single-family residence; economic payback period is 19 years. Benefits for all sites depend on maintenance or decrease of initial investment required and continuing increase in cost of conventional energy. Report includes analysis weighing potential changes in variables used to evaluate system profitability.

  1. Diminishing Manufacturing Sources and Material Shortages (DMSMS) Guidebook

    DTIC Science & Technology

    2006-11-01

    www.dau.mil/registrar/enroll.aspx DoD Acquisition, Technology, and Logistics (AT&L) Integrated Framework Chart (IFC) lifecycle activities and...ROI) and Break Even Point ( BEP ). Two analysts could look at the same data and generate different outcomes if they use different assumptions or...principal output of the BCA is the Break Even Point ( BEP ), which shows the payback period of an alternative. It is found from a plot of the

  2. Architecturally sensitive retrofitting of PV to a residential block in Greece to reduce its carbon footprint

    NASA Astrophysics Data System (ADS)

    Panopoulou, Ismini

    Photovoltaic power is a unique energy source, with wide distribution potential, which can be integrated within the fabric of individual buildings, transforming the power generation in a less large-scale and regionally located issue. As a result, photovoltaic power is a free, clean and silent electrical supply that can be introduced into cities and residential areas. Over the past years, grid-connected, distributed photovoltaic power systems have become an explosively growing sector worldwide. This trend is expected to be continued in the future and solar systems may become a common building element of building construction. In Greece, where the main focus of the project is concentrated, the extended sunshine and the incentives of the new Renewable Energy Sources law of 2006, give a different perspective in photovoltaic investments. In the case study of Vera Water Residence complex in Athens, the viability of an architecturally sensitive retrofitting of PV was examined, from both financial and environmental aspects. The project was concentrated in one of the complex's buildings which was modelled in TAS simulator in order for the annual heating and cooling loads to be estimated. A closer to the reality estimation of electricity demand was made through the annual electricity bills of the building. The proposed building integrated photovoltaic system was designed in terms of following and respecting the aesthetics of the existing architecture of the complex while being as efficient as possible. The annual energy output and C02 emissions reductions were then calculated through RETScreen software analysis according to the location of the project and the characteristics of the PV system. Finally, an economic analysis has been included to the study, considering the installation cost, the annual savings and the embodied energy of the system, in order for the payback period of the investment to be determined. Finally, a small sensitivity analysis concerning the effect of different factors influencing the feasibility of the PV investment was carried out and as it was expected it had significant effect on the initially calculated the payback period value. The expected future increase of fuel prices and the reduction of the investment's initial cost due to government grants, added to the prospect of new future tax incentive and subsidies, have made the prospect of the project more attractive while significantly reducing the payback period.

  3. Extraction of astaxanthin from microalgae: process design and economic feasibility study

    NASA Astrophysics Data System (ADS)

    Zgheib, Nancy; Saade, Roxana; Khallouf, Rindala; Takache, Hosni

    2018-03-01

    In this work, the process design and the economic feasibility of natural astaxanthin extraction fromHaematococcus pluvialisspecies have been reported. Complete process drawing of the process was first performed, and then the process was designed including five main steps being the harvesting process, the cell disruption, the spray drying, the supercritical CO2extraction and the anaerobic digestion. The major components of the facility would include sedimentation tanks, a disk stack centrifuge, a bed miller, a spray dryer, a multistage compressor, an extractor, a pasteurizer and a digester. All units have been sized assuming a 10 kg/h of dried biomass as a feedstock to produce nearly 2592 kg of astaxanthin per year. The investment payback time and the return on investment were all estimated for different market prices of astaxanthin. Based on the results the production process was found to become economically feasible for a market price higher than 1500/Kg. Also, a payback period of 1 year and an ROI equal to 113% was estimated for an astaxanthin market price equal to 6000/Kg.

  4. Wastewater recycling and heat reclamation at the Red Lion Central Laundry, Portland, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlick, T.F.; Halverson, M.A.; Ledbetter, M.R.

    1996-09-01

    This report discusses water, energy, and cost savings that can be achieved in a commercial laundry through the use of a wastewater recycling and heat recovery system. Cost savings are achieved through reductions in water use, reduction in sewage charges, reductions in water heating energy, and potential reductions in water treatment chemicals. This report provides an economic analysis of the impact of capital investment, daily consumption, and local utility rates on the payback period.

  5. Study on Use of Fuel-Cell Auxiliary Power Units in Refrigerator Cars Employed for Delivery to Convenience Store

    NASA Astrophysics Data System (ADS)

    Katayama, Noboru; Kamiyama, Hideyuki; Kogoshi, Sumio; Kudo, Yusuke; Fukada, Takafumi; Ogawa, Makoto

    The use of fuel-cell auxiliary power units (FC-APU) in refrigerator cars employed delivery to for convenience store delivery has been studied. The delivery pattern is assumed to be a typical pattern that includes driving between convenience stores or between a delivery center and a convenience store, unloading, driver's lunch break. The M15 driving mode, which simulates the driving condition in urban areas, is used as the driving mode in the delivery pattern. The FC-APU system includes a proton-exchange membrane fuel cell (PEFC) module, an inverter, and DC/DC converter. Bench tests of the FC-APU are performed to determine the hydrogen fuel consumption rate and the energy efficiency; these values depend on the output power of the PEFC module. The calculated relationship between the output power and fuel consumption rate of a current used system, which consists of an alternator and a secondary battery, are used to estimate the energy efficiency of the current used system. On the basis of the measurement data in this study and the results for the model proposed by Brodric et al. [C. J. Brodrick et al., Trans. Res. D, vol 7, pp. 303 (2002)], the payback period is calculated. The results indicate that the payback period would be 2.1 years when the FC-APU operates at a load of 70%.

  6. Economic analysis of solar assisted absorption chiller for a commercial building

    NASA Astrophysics Data System (ADS)

    Antonyraj, Gnananesan

    Dwindling fossil fuels coupled with changes in global climate intensified the drive to make use of renewable energy resources that have negligible impact on the environment. In this attempt, the industrial community produced various devices and systems to make use of solar energy for heating and cooling of building space as well as generate electric power. The most common components employed for collection of solar energy are the flat plate and evacuated tube collectors that produce hot water that can be employed for heating the building space. In order to cool the building, the absorption chiller is commonly employed that requires hot water at high temperatures for its operation. This thesis deals with economic analysis of solar collector and absorption cooling system to meet the building loads of a commercial building located in Chattanooga, Tennessee. Computer simulations are employed to predict the hourly building loads and performance of the flat plate and evacuated tube solar collectors using the hourly weather data. The key variables affecting the economic evaluation of such system are identified and the influence of these parameters is presented. The results of this investigation show that the flat plate solar collectors yield lower payback period compared to the evacuated tube collectors and economic incentives offered by the local and federal agencies play a major role in lowering the payback period.

  7. Retention payoff-based cost per day open regression equations: Application in a user-friendly decision support tool for investment analysis of automated estrus detection technologies.

    PubMed

    Dolecheck, K A; Heersche, G; Bewley, J M

    2016-12-01

    Assessing the economic implications of investing in automated estrus detection (AED) technologies can be overwhelming for dairy producers. The objectives of this study were to develop new regression equations for estimating the cost per day open (DO) and to apply the results to create a user-friendly, partial budget, decision support tool for investment analysis of AED technologies. In the resulting decision support tool, the end user can adjust herd-specific inputs regarding general management, current reproductive management strategies, and the proposed AED system. Outputs include expected DO, reproductive cull rate, net present value, and payback period for the proposed AED system. Utility of the decision support tool was demonstrated with an example dairy herd created using data from DairyMetrics (Dairy Records Management Systems, Raleigh, NC), Food and Agricultural Policy Research Institute (Columbia, MO), and published literature. Resulting herd size, rolling herd average milk production, milk price, and feed cost were 323 cows, 10,758kg, $0.41/kg, and $0.20/kg of dry matter, respectively. Automated estrus detection technologies with 2 levels of initial system cost (low: $5,000 vs. high: $10,000), tag price (low: $50 vs. high: $100), and estrus detection rate (low: 60% vs. high: 80%) were compared over a 7-yr investment period. Four scenarios were considered in a demonstration of the investment analysis tool: (1) a herd using 100% visual observation for estrus detection before adopting 100% AED, (2) a herd using 100% visual observation before adopting 75% AED and 25% visual observation, (3) a herd using 100% timed artificial insemination (TAI) before adopting 100% AED, and (4) a herd using 100% TAI before adopting 75% AED and 25% TAI. Net present value in scenarios 1 and 2 was always positive, indicating a positive investment situation. Net present value in scenarios 3 and 4 was always positive in combinations using a $50 tag price, and in scenario 4, the $5,000, $100, and 80% combination. Overall, the payback period ranged from 1.6 yr to greater than 10 yr. Investment analysis demonstration results were highly dependent on assumptions, especially AED system initial investment and labor costs. Dairy producers can use herd-specific inputs with the cost per day open regression equations and the decision support tool to estimate individual herd results. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Natural Gas Use On Minibuses, Engaged In The Carriage Of Passengers And Baggage On The Regular Routes, As A Measure For Decrease In Harmful Environment Effects

    NASA Astrophysics Data System (ADS)

    Chikishev, E.; Chikisheva, A.; Anisimov, I.; Chainikov, D.

    2017-01-01

    The paper deals with an option of increase the compressed natural gas use as a motor fuel for diesel minibuses to reduce emissions of harmful substances with exhaust gases. In terms of the Russian company LTD "WTC Automobilist", carrying passengers and baggage on regular routes by minibuses, the calculation of the park's natural gas needs is promoted. A mini CNG RS with optimal performance is suggested. The approximate payback period of the natural gas equipment installation on all buses of company and introduction into service period of mini CNG RS are calculated.

  9. Outcome-Driven Service Provider Performance under Conditions of Complexity and Uncertainty, Defense Acquisition in Transition, Volume 2, 13-14 May 2009.

    DTIC Science & Technology

    2009-04-22

    bandwidth and response times. Forrester Research uses the analogy of a consumer using an automated teller machine to explain how technical SLAs should...be crafted. “It’s not enough that you put your card and Personal Identification Number (PIN) [in the machine ] and request to withdraw cash...IRR) Net Present Value (NPV) Other Relevant Metrics Payback Period Cost/Benefit Ratio Cost, Economic, and/or Financial Analysis Yes Yes Yes

  10. Capital planning for clinical integration.

    PubMed

    Grauman, Daniel M; Neff, Gerald; Johnson, Molly Martha

    2011-04-01

    When assessing the financial implications of a physician alignment and clinical integration initiative, a hospital should measure the initiative's potential ROI, perhaps best using a combination of net present value and payback period. The hospital should compare its own historical and projected performance with rating agency median benchmarks for key financial indicators of profitability, debt service, capital and cash flow, and liquidity. The hospital should also consider potential indirect benefits, such as retained outpatient/ancillary revenue, increased inpatient revenue, improved cost control, and improved quality and reporting transparency.

  11. Associated petroleum gas utilization in Tomsk Oblast: energy efficiency and tax advantages

    NASA Astrophysics Data System (ADS)

    Vazim, A.; Romanyuk, V.; Ahmadeev, K.; Matveenko, I.

    2015-11-01

    This article deals with oil production companies activities in increasing the utilization volume of associated petroleum gas (APG) in Tomsk Oblast. Cost-effectiveness analysis of associated petroleum gas utilization was carried out using the example of gas engine power station AGP-350 implementation at Yuzhno-Cheremshanskoye field, Tomsk Oblast. Authors calculated the effectiveness taking into account the tax advantages of 2012. The implementation of this facility shows high profitability, the payback period being less than 2 years.

  12. Energy savings potential in air conditioners and chiller systems

    DOE PAGES

    Kaya, Durmus; Alidrisi, Hisham

    2014-01-22

    In the current paper we quantified and evaluated the energy saving potential in air conditioners and chiller systems. Here, we also showed how to reduce the cost of air conditioners and chiller systems in existing facilities on the basis of payback periods. Among the measures investigated were: (1) installing higher efficiency air conditioners, (2) installing higher efficiency chillers, (3) duty cycling air conditioning units, and (4) utilizing existing economizers on air conditioning units. For each method, examples were provided from Arizona, USA. In these examples, the amount of saved energy, the financial evaluation of this energy, and the investment costmore » and pay back periods were calculated.« less

  13. Management of Hazardous Waste in Indonesia

    NASA Astrophysics Data System (ADS)

    Widyatmoko, H.

    2018-01-01

    Indonesia needs to build four Treatment Centrals for 229,907 tons per year produced hazardous waste. But almost all hazardous waste treatment is managed by just one company at present, namely PT. PPLI (Prasada Pamunah Limbah Industri). This research is based on collected data which identifies payback period of 0.69 years and rate of return 85 %. PT PPLI is located within the Cileungsi District of the Bogor Regency of West Java Province. Records from nearest rainfall station at Cibinong indicate that annual average rainfall for the site is about 3,600 mm. It is situated on hilly terrain and is characterized by steep slopes as well as has a very complex geological structure. The Tertiary sequence was folded to form an assymetric anticline with axis trend in an East-West direction. Three major faults cut the middle of the site in a North-South direction with a vertical displacement of about 1.5 meters and a zone width of 1 meter. The high concentration of Chemical Oxygen Demand (COD) 2500 ppm in Secondary Leachate Collection System (SLCS) indicate a possible failure of the Primary Leachate Clection System (PLCS), which need correct action to prevent groundwater contamination.

  14. Measuring the payback of research activities: a feasible ex-post evaluation methodology in epidemiology and public health.

    PubMed

    Aymerich, Marta; Carrion, Carme; Gallo, Pedro; Garcia, Maria; López-Bermejo, Abel; Quesada, Miquel; Ramos, Rafel

    2012-08-01

    Most ex-post evaluations of research funding programs are based on bibliometric methods and, although this approach has been widely used, it only examines one facet of the project's impact, that is, scientific productivity. More comprehensive models of payback assessment of research activities are designed for large-scale projects with extensive funding. The purpose of this study was to design and implement a methodology for the ex-post evaluation of small-scale projects that would take into account both the fulfillment of projects' stated objectives as well as other wider benefits to society as payback measures. We used a two-phase ex-post approach to appraise impact for 173 small-scale projects funded in 2007 and 2008 by a Spanish network center for research in epidemiology and public health. In the internal phase we used a questionnaire to query the principal investigator (PI) on the outcomes as well as actual and potential impact of each project; in the external phase we sent a second questionnaire to external reviewers with the aim of assessing (by peer-review) the performance of each individual project. Overall, 43% of the projects were rated as having completed their objectives "totally", and 40% "considerably". The research activities funded were reported by PIs as socially beneficial their greatest impact being on research capacity (50% of payback to society) and on knowledge translation (above 11%). The method proposed showed a good discriminating ability that makes it possible to measure, reliably, the extent to which a project's objectives were met as well as the degree to which the project contributed to enhance the group's scientific performance and of its social payback. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Vacuum boilers developed heating surfaces technic and economic efficiency evaluation

    NASA Astrophysics Data System (ADS)

    Slobodina, E. N.; Mikhailov, A. G.; Semenov, B. A.

    2018-01-01

    The vacuum boilers as manufacturing proto types application analysis was carried out, the possible directions for the heating surfaces development are identified with a view to improving the energy efficiency. Economic characteristics to evaluate the vacuum boilers application efficiency (Net Discounted Income (NDI), Internal Rate of Return (IRR), Profitability Index (PI) and Payback Period) are represented. The given type boilers application technic and economic efficiency criteria were established. NDI changing curves depending on the finning coefficient and operating pressure were obtained as a result of the conducted calculation studies.

  16. Economical Development of Complex Computer Systems

    DTIC Science & Technology

    1992-08-15

    margins typically encountered in the ........ beginning of a product’s life cycle, and shorten the payback period.4 leS D ~~~~LC~~~ Jr4.tt L~s.c...recurring, and other related costsincurred, or estimated to be incurr in the design, research and development (R& D ), investment, operation, maintenance...on the basis of cost. D E C R ’Item I E Incorporatento A-ml S .... .. EF D Y ..... S F R Technology& : Recnser 0 N P T Item N A -- Y E -- B N ’’A D

  17. Ambulatory electronic medical record payback analysis 7 years after implementation in a tertiary care county medical system.

    PubMed

    Kaelber, David C; Miller, Vince; Fisher, Nancy; Schlesinger, Jim; Norris, Greg

    2007-10-11

    Electronic medical records (EMRs) are gaining increasing prominence in healthcare, however still have low market penetration. EMR implementation cost is a primary perceived barrier. Here we present a payback analysis on an outpatient EMR implementation, showing capital expense recovery (net of operating costs) at 6 years and now generating $6 million yearly in direct savings for our healthcare system.

  18. Losses Disguised as Wins Affect Game Selection on Multiline Slots.

    PubMed

    Graydon, Candice; Stange, Madison; Dixon, Mike J

    2018-05-05

    Multiline slots are exciting games that contain features which make them alluring. One such feature is a loss disguised as a win (LDW); wherein, players win less than they wager (e.g., bet 2 dollars, win back 50 cents), but this net loss is disguised by flashing graphics and winning sounds. Research to date concludes that LDWs are both rewarding and reinforcing. Here, we investigated whether LDWs affect players' game selection. Thirty-two undergraduate students with experience playing slot machines played 100 spins on four games-two had positive payback percentages (115%) and two had negative payback percentages (85%) after 100 spins. For each payback percentage condition, there was a game with no LDWs and a game with a moderate number of LDWs. For the 100 spins, players could choose to play whichever game they wished. They then rated their preference for each game following the 100-spins and chose a game to continue playing. The majority of players preferred playing the positive payback percentage game with LDWs and chose to continue playing this game over the three other games. We conclude that in addition to LDWs being reinforcing and rewarding, LDWs do in fact influence game selection. We conclude that responsible gambling initiatives should educate players about LDWs.

  19. Construction costs, payback times, and the leaf economics of carnivorous plants.

    PubMed

    Karagatzides, Jim D; Ellison, Aaron M

    2009-09-01

    Understanding how different plant species and functional types "invest" carbon and nutrients is a major goal of plant ecologists. Two measures of such investments are "construction costs" (carbon needed to produce each gram of tissue) and associated "payback times" for photosynthesis to recover construction costs. These measurements integrate among traits used to assess leaf-trait scaling relationships. Carnivorous plants are model systems for examining mechanisms of leaf-trait coordination, but no studies have measured simultaneously construction costs of carnivorous traps and their photosynthetic rates to determine payback times of traps. We measured mass-based construction costs (CC(mass)) and photosynthesis (A(mass)) for traps, leaves, roots, and rhizomes of 15 carnivorous plant species grown under greenhouse conditions. There were highly significant differences among species in CC(mass) for each structure. Mean CC(mass) of carnivorous traps (1.14 ± 0.24 g glucose/g dry mass) was significantly lower than CC(mass) of leaves of 267 noncarnivorous plant species (1.47 ± 0.17), but all carnivorous plants examined had very low A(mass) and thus, long payback times (495-1551 h). Our results provide the first clear estimates of the marginal benefits of botanical carnivory and place carnivorous plants at the "slow and tough" end of the universal spectrum of leaf traits.

  20. Economic feasibility of cooling dry cows across the United States.

    PubMed

    Ferreira, F C; Gennari, R S; Dahl, G E; De Vries, A

    2016-12-01

    Heat stress during the dry period reduces milk yield in the subsequent lactation of dairy cows. Our objectives were to quantify the economic losses due to heat stress if dry cows are not cooled and to evaluate the economic feasibility of dry cow cooling. We used weather data from the National Oceanic and Atmospheric Administration to calculate the number of heat stress days for each of the 50 US states. A heat stress day was declared when the daily average temperature-humidity index was ≥68. The number of dairy cows in each state in 2015 was obtained from the USDA-National Agricultural Statistics Service. We assumed that 15% of the cows were dry at any time, a 60-d dry period, and a calving interval of 400d. Only cows in their second or greater parity (65%) benefitted from cooling during the dry period of the previous parity. Milk yield decreased by 5kg in the subsequent lactation (340d) if the cow experienced heat stress during the dry period based on a review of the literature. The default marginal value of milk minus feed cost was $0.33/kg of milk. The investment analysis included purchases of fans and soakers and use of water and electricity. Investment in a dry cow barn was considered separately. The average US dairy cow would experience 96 (26%) heat stress days during the year if not cooled and loses 447kg of milk in the subsequent lactation if not cooled when dry. Annual losses would be $810 million if dry cows were not cooled ($87/cow per yr). For the top 3 milk-producing states (California, Wisconsin, New York), and Florida and Texas, the average milk losses in the subsequent lactation were 522, 349, 387, 1,197, and 904kg, and reduced profit per cow per year would be $101, $68, $75, $233, and $176, respectively. The average benefit-cost ratio and payback periods of cooling dry cows in the United States were 3.15 and 0.27 yr (dry cow barn already present) and 1.45 and 5.68 yr (if investing in a dry cow barn) in the default scenario. To reach positive net present values, 6d (barn is present) and 55d (barn investment necessary) of heat stress annually were necessary (default assumptions). Other benefits of cooling, such as increased health and more productive offspring, were not considered. In conclusion, cooling of dry cows was profitable for 89% of the cows in the United States when building a new barn is required (under default assumptions) and very profitable when construction of a dry cow barn is not required (except for Alaska). Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. Comparative economics of space resource utilization

    NASA Technical Reports Server (NTRS)

    Cutler, Andrew Hall

    1991-01-01

    Physical economic factors such as mass payback ratio, total payback ratio, and capital payback time are discussed and used to compare the economics of using resources from the Moon, Mars and its moons, and near Earth asteroids to serve certain near term markets such as propellant in low Earth orbit or launched mass reduction for lunar and Martian exploration. Methods for accounting for the time cost of money in simple figures of merit such as MPRs are explored and applied to comparisons such as those between lunar, Martian, and asteroidal resources. Methods for trading off capital and operating costs to compare schemes with substantially different capital to operating cost ratio are presented and discussed. Areas where further research or engineering would be extremely useful in reducing economic uncertainty are identified, as are areas where economic merit is highly sensitive to engineering performance - as well as areas where such sensitivity is surprisingly low.

  2. Geotheral heating facilities of United Church of Christ (Congregational Church)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-01

    Based on the assumptions made in this study, a geothermal system for the Congregational Church is not economically feasible at this time. A retrofit of the church for geothermal would result in a capital cost of $37,600 including the geothermal well. When this figure is considered in conjunction with the $1892 first-year savings (present fuel cost minus geothermal system O and M cost) and inflation over a 20-year period, a simple payback of 12 years results. In addition, an internal rate of return figure of 8.7 percent was generated. This indicates that the project would have to be financed atmore » less than 9 percent to be economically feasible over a 20-year period.« less

  3. Need for Systematic Retrofit Analysis in Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malhotra, Mini; Im, Piljae

    2014-01-01

    Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets ofmore » measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.« less

  4. A financial feasibility model of gasification and anaerobic digestion waste-to-energy (WTE) plants in Saudi Arabia.

    PubMed

    Hadidi, Laith A; Omer, Mohamed Mahmoud

    2017-01-01

    Municipal Solid Waste (MSW) generation in Saudi Arabia is increasingly growing at a fast rate, as it hurtles towards ever increasing urban development coupled with rapid developments and expanding population. Saudi Arabia's energy demands are also rising at a faster rate. Therefore, the importance of an integrated waste management system in Saudi Arabia is increasingly rising and introducing Waste to Energy (WTE) facilities is becoming an absolute necessity. This paper analyzes the current situation of MSW management in Saudi Arabia and proposes a financial model to assess the viability of WTE investments in Saudi Arabia in order to address its waste management challenges and meet its forecasted energy demands. The research develops a financial model to investigate the financial viability of WTE plants utilizing gasification and Anaerobic Digestion (AD) conversion technologies. The financial model provides a cost estimate of establishing both gasification and anaerobic digestion WTE plants in Saudi Arabia through a set of financial indicators, i.e. net present value (NPV), internal rate of return (IRR), modified internal rate of return (MIRR), profitability index (PI), payback period, discounted payback period, Levelized Cost of Electricity (LCOE) and Levelized Cost of Waste (LCOW). Finally, the analysis of the financial model reveals the main affecting factors of the gasification plants investment decision, namely: facility generation capacity, generated electricity revenue, and the capacity factor. Similarly, the paper also identifies facility waste capacity and the capacity factor as the main affecting factors on the AD plants' investment decision. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Water Conservation Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ian Metzger, Jesse Dean

    2010-12-31

    This software requires inputs of simple water fixture inventory information and calculates the water/energy and cost benefits of various retrofit opportunities. This tool includes water conservation measures for: Low-flow Toilets, Low-flow Urinals, Low-flow Faucets, and Low-flow Showheads. This tool calculates water savings, energy savings, demand reduction, cost savings, and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

  6. Techno-Economic analysis of solar photovoltaic power plant for small scale fish processing in Kota Langsa - a case study

    NASA Astrophysics Data System (ADS)

    Widodo, S. B.; Hamdani; Rizal, T. A.; Pambudi, N. A.

    2018-02-01

    In Langsa, fisheries are the sector leaders by fulfilling a capacity of about 6,050 tons per year and on the other hand, fish-aquaculture reaches 1,200 tons per year on average. The fish processing is conducted through catches and aquaculture. The facilities on which this processing takes place are divided into an ice factory unit, a gutting and cutting unit, a drying unit and a curing unit. However, the energy and electricity costs during the production process has become major constraint because of the increase in the fishermen’s production and income. In this study, the potential and cost-effectiveness of photovoltaic solar power plant to meet the energy demands of fish processing units have been analysed. The energy requirements of fish processing units have reached an estimate of 130 kW, while the proposed design of solar photovoltaic electricity generation is of 200 kW in an area of 0,75 hectares. In this analysis, given the closeness between the location of the processing units and the fish supply auctions, the assumption is made that the photovoltaic plants (OTR) were installed on the roof of the building as compared to the solar power plants (OTL) installed on the outside of the location. The results shows that the levelized cost of OTR instalation is IDR 1.115 per kWh, considering 25 years of plant life-span at 10% of discount rate, with a simple payback period of 13.2 years. OTL levelized energy, on the other hand, is at IDR 997.5 per kWh with a simple payback period of 9.6 years. Blood is an essential component of living creatures in the vascular space. For possible disease identification, it can be tested through a blood test, one of which can be seen from the form of red blood cells. The normal and abnormal morphology of the red blood cells of a patient is very helpful to doctors in detecting a disease. With the advancement of digital image processing technology can be used to identify normal and abnormal blood cells of a patient. This research used self-organizing map method to classify the normal and abnormal form of red blood cells in the digital image. The use of self-organizing map neural network method can be implemented to classify the normal and abnormal form of red blood cells in the input image with 93,78% accuracy testing.

  7. Retrofitting LID Practices into Existing Neighborhoods: Is It Worth It?

    NASA Astrophysics Data System (ADS)

    Wright, Timothy J.; Liu, Yaoze; Carroll, Natalie J.; Ahiablame, Laurent M.; Engel, Bernard A.

    2016-04-01

    Low-impact development (LID) practices are gaining popularity as an approach to manage stormwater close to the source. LID practices reduce infrastructure requirements and help maintain hydrologic processes similar to predevelopment conditions. Studies have shown LID practices to be effective in reducing runoff and improving water quality. However, little has been done to aid decision makers in selecting the most effective practices for their needs and budgets. The long-term hydrologic impact assessment LID model was applied to four neighborhoods in Lafayette, Indiana using readily available data sources to compare LID practices by analyzing runoff volumes, implementation cost, and the approximate period needed to achieve payback on the investment. Depending on the LID practice and adoption level, 10-70 % reductions in runoff volumes could be achieved. The cost per cubic meter of runoff reduction was highly variable depending on the LID practice and the land use to which it was applied, ranging from around 3 to almost 600. In some cases the savings from reduced runoff volumes paid back the LID practice cost with interest in less than 3 years, while in other cases it was not possible to generate a payback. Decision makers need this information to establish realistic goals and make informed decisions regarding LID practices before moving into detailed designs, thereby saving time and resources.

  8. Impact of composites on future transport aircraft

    NASA Technical Reports Server (NTRS)

    Kinder, Robert H.

    1993-01-01

    In the current environment, new technology must be cost-effective in addition to improving operability. Various approaches have been used to determine the 'hurdle' or 'breakthrough' return that must be achieved to gain customer commitment for a new product or aircraft, or in this case, a new application of the technology. These approaches include return-on-investment, payback period, and addition to net worth. An easily understood figure-of-merit and one used by our airline customers is improvement in direct operating cost per seat-mile. Any new technology must buy its way onto the aircraft through reduction in direct operating cost (DOC).

  9. Life-cycle economics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lunde, P.J.

    1982-09-01

    In a continuation of previous economic analyses, life-cycle economics of solar projects are discussed using the concept of net present value (NPV) or net worth. The discount rate is defined and illustrated and a life-cycle analysis is worked out based on no down payment and a 25-year loan. The advantages of rising NPV are discussed and illustrated using an energy conserving $100 storm window as an example. Real payback period is discussed and it is concluded that NPV is the only valid method for the evaluation of an investment. Return on investment is cited as a satisfactory alternative method. (MJJ)

  10. Early action to reduce greenhouse gas emissions before the commitment period of the Kyoto protocol: advantages and disadvantages.

    PubMed

    Michaelowa, A; Rolfe, C

    2001-09-01

    Current "business as usual" projections suggest greenhouse gas emissions from industrialized nations will grow substantially over the next decade. However, if it comes into force, the Kyoto Protocol will require industrialized nations to reduce emissions to an average of 5% below 1990 levels in the 2008-2012 period. Taking early action to close this gap has a number of advantages. It reduces the risks of passing thresholds that trigger climate change "surprises." Early action also increases future generations' ability to choose greater levels of climate protection, and it leads to faster reductions of other pollutants. From an economic sense, early action is important because it allows shifts to less carbon-intensive technologies during the course of normal capital stock turnover. Moreover, many options for emission reduction have negative costs, and thus are economically worthwhile, because of paybacks in energy costs, healthcare costs, and other benefits. Finally, early emission reductions enhance the probability of successful ratification and lower the risk of noncompliance with the protocol. We discuss policy approaches for the period prior to 2008. Disadvantages of the current proposals for Credit for Early Action are the possibility of adverse selection due to problematic baseline calculation methods as well as the distributionary impacts of allocating a part of the emissions budget already before 2008. One simple policy without drawbacks is the so-called baseline protection, which removes the disincentive to early action due to the expectation that businesses may, in the future, receive emission rights in proportion to past emissions. It is particularly important to adopt policies that shift investment in long-lived capital stock towards less carbon-intensive technologies and to encourage innovation and technology development that will reduce future compliance costs.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, W.N.

    This report summarizes measured performance of residential geothermal heat pumps (GHP`s) that were installed in family housing units at Ft. Hood, Texas and at Selfridge Air National Guard base in Michigan. These units were built as part of a joint Department of Defense/Department of Energy program to evaluate the energy savings potential of GHP`s installed at military facilities. At the Ft. Hood site, the GHP performance was compared to conventional forced air electric air conditioning and natural gas heating. At Selfridge, the homes under test were originally equipped with electric baseboard heat and no air conditioning. Installation of the GHPmore » systems at both sites was straightforward but more problems and costs were incurred at Selfridge because of the need to install ductwork in the homes. The GHP`s at both sites produced impressive energy savings. These savings approached 40% for most of the homes tested. The low cost of energy on these bases relative to the incremental cost of the GHP conversions precludes rapid payback of the GHP`s from energy savings alone. Estimates based on simple payback (no inflation and no interest on capital) indicated payback times from 15 to 20 years at both sites. These payback times may be reduced by considering the additional savings possible due to reduced maintenance costs. Results are summarized in terms of 15 minute, hourly, monthly, and annual performance parameters. The results indicate that all the systems were working properly but several design shortcomings were identified. Recommendations are made for improvements in future installations at both sites.« less

  12. A systematic review of occupational safety and health business cases.

    PubMed

    Verbeek, Jos; Pulliainen, Marjo; Kankaanpää, Eila

    2009-12-01

    Business cases are commonly developed as means to rationalize investment. We systematically reviewed 26 reported cases on occupational safety and health (OSH) interventions to assess if health and productivity arguments make a good business case. To be included in the review, studies had to analyze the costs and benefits, including productivity, of an OSH intervention at the enterprise level. We searched Medline and Embase for studies and used Google search in addition. Two reviewers independently selected studies and extracted data. The intervention profitability was calculated in euros (euro in 2008) as the first year's benefits minus the total intervention costs per worker. The payback period was calculated as the intervention costs divided by the first year's benefits. We found three ex-ante and 23 ex-post cases. In 20 cases, the study design was a before-after comparison without a control group. Generally a 100% reduction of injuries or sickness absence was assumed. In two cases, productivity and quality increases were very large. The main benefit was avoided sick leave. Depreciation or discounting was applied only in a minority of cases. The intervention profitability was negative in seven studies, up to euro 500 per employee in 12 studies and more than euro 500 per employee in seven studies. The payback period was less than half a year for 19 studies. Only a few studies included sensitivity analyses. Few ex-ante business cases for management decisions on OSH are reported. Guidelines for reporting and evaluation are needed. Business cases need more sound assumptions on the effectiveness of interventions and should incorporate greater uncertainty into their design. Ex-post evaluation should be based preferably on study designs that control for trends at a time different from that of the intervention.

  13. The Impacts of Changes to Nevada's Net Metering Policy on the Financial Performance and Adoption of Distributed Photovoltaics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gagnon, Pieter; Sigrin, Ben; Gleason, Mike

    As the adoption of distributed photovoltaics (DPV) has continued to rapidly increase, a national conversation has begun about the efficacy of full-retail net metering as a means of achieving the diverse objectives of electricity pricing. This conversation has prompted studies that have primarily focused on the total costs and benefits of DPV. To compliment those studies, we here characterize the potential impacts of tariff design on the customer-economics and adoption of DPV, where recent changes in Nevada are taken as a case study. We show that an increase in fixed charges more strongly impacts the payback period of small systems,more » and a decrease in credit for exported electricity more strongly impacts the payback period of large systems. We project that these combined changes will reduce DPV adoption in Nevada; total capacity in 2030 was projected to reach up to 363 MW, with 226 MW having already been installed at the end of the second quarter of 2016. In contrast, if full retail net metering had continued, DPV capacity was projected to reach up to 1,280 MW at the end of 2030, which would account for an estimated 6.5% of the total sales of electricity by NV Energy at that time. We project that the DPV systems will decrease the gross revenue from bill collection by $48 million per year under the new tariffs, whereas the decrease in gross revenue could have reached $255 million per year if full retail net metering had been continued. Although these results are given in the context of Nevada, the trends shown are intended to help information similar upcoming decisions in other states.« less

  14. Technical-financial evaluation of rainwater harvesting systems in commercial buildings-case ase studies from Sonae Sierra in Portugal and Brazil.

    PubMed

    Sousa, Vitor; Silva, Cristina Matos; Meireles, Inês C

    2017-11-10

    Water is an essential and increasingly scarce resource that should be preserved. The evolution of the human population and communities has contributed to the global decrease of potable water availability and the reduction of its consumption is now compulsory. Rainwater harvesting systems (RWHS) are emerging as a viable alternative source for water consumption in non-potable uses. The present study aims to contribute to the promotion of water efficiency, focusing on the application of rainwater harvesting systems in commercial buildings, and comprises four stages: (i) development of a technical evaluation tool to aid the design of RWHS and support their financial evaluation; (ii) validation of the tool using operational data from an existing RWHS installed at Colombo Shopping Center, in Lisbon, Portugal; (iii) assessment of the sensibility of the technical evaluation tool results to the variation of the inputs, namely the precipitation and consumption, through a parametric analysis for the Colombo Shopping Center; and (iv) comparison of the performance and financial feasibility of hypothetical RWHS in two existing commercial buildings. The technical tool was applied to two Sonae Sierra's shopping centers, one in Portugal and one in Brazil. The installation of a 200-m 3 tank is advised for the first case study, allowing non-potable water savings of 60% but a payback period of about 19 years. In the Brazilian shopping, the implementation of a tank with a capacity ranging from 100 to 400 m 3 leads to non-potable savings between 20 and 50%, but with smaller payback period, under 2 years, due to the relatively lower investment costs and higher water fees.

  15. Optimal Renewable Energy Integration into Refinery with CO2 Emissions Consideration: An Economic Feasibility Study

    NASA Astrophysics Data System (ADS)

    Alnifro, M.; Taqvi, S. T.; Ahmad, M. S.; Bensaida, K.; Elkamel, A.

    2017-08-01

    With increasing global energy demand and declining energy return on energy invested (EROEI) of crude oil, global energy consumption by the O&G industry has increased drastically over the past few years. In addition, this energy increase has led to an increase GHG emissions, resulting in adverse environmental effects. On the other hand, electricity generation through renewable resources have become relatively cost competitive to fossil based energy sources in a much ‘cleaner’ way. In this study, renewable energy is integrated optimally into a refinery considering costs and CO2 emissions. Using Aspen HYSYS, a refinery in the Middle East was simulated to estimate the energy demand by different processing units. An LP problem was formulated based on existing solar energy systems and wind potential in the region. The multi-objective function, minimizing cost as well as CO2 emissions, was solved using GAMS to determine optimal energy distribution from each energy source to units within the refinery. Additionally, an economic feasibility study was carried out to determine the viability of renewable energy technology project implementation to overcome energy requirement of the refinery. Electricity generation through all renewable energy sources considered (i.e. solar PV, solar CSP and wind) were found feasible based on their low levelized cost of electricity (LCOE). The payback period for a Solar CSP project, with an annual capacity of about 411 GWh and a lifetime of 30 years, was found to be 10 years. In contrast, the payback period for Solar PV and Wind were calculated to be 7 and 6 years, respectively. This opens up possibilities for integrating renewables into the refining sector as well as optimizing multiple energy carrier systems within the crude oil industry

  16. Implementing a resident lifting system in an extended care hospital. Demonstrating cost-benefit.

    PubMed

    Spiegel, Jerry; Yassi, Analee; Ronald, Lisa A; Tate, Robert B; Hacking, Penny; Colby, Teresa

    2002-03-01

    1. Implemeting mechanical resident lifting equipment in an extended care facility produced a payback from direct savings alone within 4 years. Payback occurred more quickly when the effect of indirect savings or the trend to rising compensation costs was considered. 2. Combining the observations of the occupational health nurses related to staff well being with relevant cost-benefit data is useful in influencing decision makers and in securing funding for prevention measures. 3. Clear identification of a viewpoint is an important part of an economic evaluation and cost-benefit analysis.

  17. Systems Analysis and Design for Decision Support Systems on Economic Feasibility of Projects

    NASA Astrophysics Data System (ADS)

    Balaji, S. Arun

    2010-11-01

    This paper discuss about need for development of the Decision Support System (DSS) software for economic feasibility of projects in Rwanda, Africa. The various economic theories needed and the corresponding formulae to compute payback period, internal rate of return and benefit cost ratio of projects are clearly given in this paper. This paper is also deals with the systems flow chart to fabricate the system in any higher level computing language. The various input requirements from the projects and the output needed for the decision makers are also included in this paper. The data dictionary used for input and output data structure is also explained.

  18. Congeneration feasibility: Otis Elavator Company and Polychrome Corporation

    NASA Astrophysics Data System (ADS)

    Fox, H.

    1982-05-01

    An investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY is discussed. Existing electrical and steam producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return on investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, this detailed study provides valuable insights.

  19. Solar silicon via the Dow Corning process

    NASA Technical Reports Server (NTRS)

    Hunt, L. P.; Dosaj, V. D.

    1979-01-01

    Technical feasibility for high volume production of solar cell-grade silicon is investigated. The process consists of producing silicon from pure raw materials via the carbothermic reduction of quartz. This silicon was then purified to solar grade by impurity segregation during Czochralski crystal growth. Commercially available raw materials were used to produce 100 kg quantities of silicon during 60 hour periods in a direct arc reactor. This silicon produced single crystalline ingot, during a second Czochralski pull, that was fabricated into solar cells having efficiencies ranging from 8.2 percent to greater than 14 percent. An energy analysis of the entire process indicated a 5 month payback time.

  20. Building America Case Study: Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  1. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency watermore » heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  2. Simple Retrofit High-Efficiency Natural Gas Water Heater Field Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben

    High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiencymore » water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.« less

  3. Sustainability Efficiency Factor: Measuring Sustainability in Advanced Energy Systems through Exergy, Exergoeconomic, Life Cycle, and Economic Analyses

    NASA Astrophysics Data System (ADS)

    Boldon, Lauren

    The Encyclopedia of Life Support Systems defines sustainability or industrial ecology as "the wise use of resources through critical attention to policy, social, economic, technological, and ecological management of natural and human engineered capital so as to promote innovations that assure a higher degree of human needs fulfilment, or life support, across all regions of the world, while at the same time ensuring intergenerational equity" (Encyclopedia of Life Support Systems 1998). Developing and integrating sustainable energy systems to meet growing energy demands is a daunting task. Although the technology to utilize renewable energies is well understood, there are limited locations which are ideally suited for renewable energy development. Even in areas with significant wind or solar availability, backup or redundant energy supplies are still required during periods of low renewable generation. This is precisely why it would be difficult to make the switch directly from fossil fuel to renewable energy generation. A transition period in which a base-load generation supports renewables is required, and nuclear energy suits this need well with its limited life cycle emissions and fuel price stability. Sustainability is achieved by balancing environmental, economic, and social considerations, such that energy is produced without detriment to future generations through loss of resources, harm to the environment, etcetera. In essence, the goal is to provide future generations with the same opportunities to produce energy that the current generation has. This research explores sustainability metrics as they apply to a small modular reactor (SMR)-hydrogen production plant coupled with wind energy and storage technologies to develop a new quantitative sustainability metric, the Sustainability Efficiency Factor (SEF), for comparison of energy systems. The SEF incorporates the three fundamental aspects of sustainability and provides SMR or nuclear hybrid energy system (NHES) reference case studies to (1) introduce sustainability metrics, such as life cycle assessment, (2) demonstrate the methods behind exergy and exergoeconomic analyses, (3) provide an economic analysis of the potential for SMR development from first-of-a-kind (FOAK) to nth-of-a-kind (NOAK), thereby illustrating possible cost reductions and deployment flexibility for SMRs over large conventional nuclear reactors, (4) assess the competitive potential for incorporation of storage and hydrogen production in NHES and in regulated and deregulated electricity markets, (5) compare an SMR-hydrogen production plant to a natural gas steam methane reforming plant using the SEF, and (6) identify and review the social considerations which would support future nuclear development domestically and abroad, such as public and political/regulatory needs and challenges. The Global Warming Potential (GWP) for the SMR (300 MWth)-wind (60 MWe)-high temperature steam electrolysis (200 tons Hydrogen per day) system was calculated as approximately 874 g CO2-equivalent as part of the life cycle assessment. This is 92.6% less than the GWP estimated for steam methane reforming production of hydrogen by Spath and Mann. The unit exergetic and exergoeconomic costs were determined for each flow within the NHES system as part of the exergy/exergoeconomic cost analyses. The unit exergetic cost is lower for components yielding more meaningful work like the one exiting the SMR with a unit exergetic cost of 1.075 MW/MW. In comparison, the flow exiting the turbine has a very high unit exergetic cost of 15.31, as most of the useful work was already removed through the turning of the generator/compressor shaft. In a similar manner, the high unit exergoeconomic cost of 12.45/MW*sec is observed for the return flow to the reactors, because there is very little exergy present. The first and second law efficiencies and the exergoeconomic factors were also determined over several cases. For the first or base SMR case, first and second law efficiencies of 81.5% and 93.3% were observed respectively. With an increase in reactor outlet temperature of only 20°C, both the SMR efficiencies increased, while the exergoeconomic factor decreased by 0.2%. As part of the SMR economic analysis, specific capital and total capital investment costs (TCIC) were determined in addition to conditional effects on the net present value (NPV), levelized cost of electricity (LCOE), and payback periods. For a 1260 MWe FOAK multi-module SMR site with 7 modules, the specific capital costs were 27-38% higher than that of a 1260 MWe single large reactor site. A NOAK site, on the other hand, may be 19% lower to 18% higher than the large reactor site, demonstrating that it may break even or be even more economical in average or favorable market conditions. The NOAK TCIC for single and multi-module SMR sites were determined to be 914-1,230 million and 660-967 million per module, respectively, reflecting the substantial savings incurred with sites designed for and deployed with multiple modules. For the same NOAK 7-unit multi-module site, the LCOE was calculated as 67-84/MWh, which is slightly less than that of the conventional large reactor LCOE of 89/MWh with a weighted average cost of capital of 10%, a 50%-50% share of debt and equity, and a corporate tax rate of 35%. The payback period for the SMR site, however, is 4 years longer. Construction delays were also analyzed to compare the SMR and large reactor sites, demonstrating the SMR NPV and LCOE are less sensitive to delays. For a 3 year delay, the SMR NPV decreased by 22%, while the large reactor NPV decreased by 34.1%. Similarly the SMR and large reactor LCOEs increased by 7.8% and 8.1%, respectively. An NHES case with hydrogen production and storage was performed, illustrating how the profit share of revenue is improved with the addition of hydrogen production. Although the costs are increased with the addition, 78% of the hydrogen revenue is profit, while only 50% of the electricity generation revenue is profit. A second NHES case study was analyzed to assess the NPV, LCOE, and payback differences in deregulated and regulated electricity markets. For a 60 year lifetime, Case C (with nuclear, wind, and hydrogen production) is economical in the deregulated market with an NPV of 66.3 million and a payback period of 10 years, but not in the regulated one with an NPV of approximately -115.3 million and a payback period of 11 years. With either market type, the plants levelized costs remain $82.82/MWh, which is still reasonable with respect to prior LCOE values determined for SMR and large reactor sites. Utilizing all the methodology and results obtained and presented in this thesis, the SEF may be calculated. The NHES SEF was determined to be 18.3% higher than that of natural gas steam methane reforming, illustrating a higher level of sustainability. The SEF quantitatively uses the exergoeconomic cost and irreversibilities obtained from the exergy analysis, the GWP obtained from the life cycle assessment and costs/fees associated with emissions and pollutants, and relevant economic data obtained from an economic analysis. This reflects the environmental, socio-political, and economic pillars of sustainability.

  4. Energy management system saves $250,000 + fuel -with 4-mo payback

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massey, C.L.; Robe, K.

    1980-09-01

    Innovations made at Hershey Chocolate Company's Oakdale, California plant eliminated simultaneous cool-reheat-cycles by incorporating dead band controls into existing HVAC systems. Calculated savings of the project are about 90% of former heating and cooling energy usage for HVAC operation. Electric power savings amount to about $75,000/y, and natural gas savings about $185,000/y, using 1980 fuel costs, with an approximate 4-month payback. Because of the reduced demand for chilled water, a smaller water chiller carries full plant load for 4 to 5 months of the year without operating two existing 500-ton units.

  5. Environmental and Economic Performance of Commercial-scale Solar Photovoltaic Systems: A Field Study of Complex Energy Systems at the Desert Research Institute (DRI)

    NASA Astrophysics Data System (ADS)

    Liu, X.

    2014-12-01

    Solar photovoltaic (PV) systems are being aggressively deployed at residential, commercial, and utility scales to complement power generation from conventional sources. This is motivated both by the desire to reduce carbon footprints and by policy-driven financial incentives. Although several life cycle analyses (LCA) have investigated environmental impacts and energy payback times of solar PV systems, most results are based on hypothetical systems rather than actual, deployed systems that can provide measured performance data. Over the past five years, Desert Research Institute (DRI) in Nevada has installed eight solar PV systems of scales from 3 to 1000 kW, the sum of which supply approximately 40% of the total power use at DRI's Reno and Las Vegas campuses. The goal of this work is to explore greenhouse gas (GHG) impacts and examine the economic performance of DRI's PV systems by developing and applying a comprehensive LCA and techno-economic (TEA) model. This model is built using data appropriate for each type of panel used in the DRI systems. Power output is modeled using the National Renewable Energy Laboratory (NREL) model PVWatts. The performance of PVWatts is verified by the actual measurements from DRI's PV systems. Several environmental and economic metrics are quantified for the DRI systems, including life cycle GHG emissions and energy return. GHG results are compared with Nevada grid-based electricity. Initial results indicate that DRI's solar-derived electricity offers clear GHG benefits compared to conventional grid electricity. DRI's eight systems have GHG intensity values of 29-56 gCO2e/kWh, as compared to the GHG intensity of 212 gCO2e/kWh of national average grid power. The major source of impacts (82-92% of the total) is the upstream life cycle burden of manufacturing PV panels, which are made of either mono-crystalline or multi-crystalline silicon. Given the same type of PV panel, GHG intensity decreases as the scale of the system increases. Energy payback times of DRI's solar PV systems range from 0.5 to 1.5 years. The cost payback time for the DRI PV systems and the cost per ton of CO2 avoided by replacing Nevada-specific electrical power will be determined. The sensitivity of these environmental and economic impacts with respect to specific model parameters is being investigated.

  6. Leadership, institution building and pay-back of health systems research in Mexico

    PubMed Central

    González-Block, Miguel Angel

    2009-01-01

    Background Health systems research is being increasingly called upon to support scaling up of disease control interventions and to support rapid health sector change. Yet research capacity building and pay-back take years or even decades to be demonstrated, while leadership and institution building are critical for their success. The case of Mexico can be illustrative for middle income countries and emerging economies striving to build health research systems. Methods Historical reflection suggests the relationship between health sector reforms and economic crisis, on the one hand, and research capacity building and payback, on the other. Mexico's post-revolutionary background and its three health sector reforms are analyzed to identify the emphases given to health systems research. Results The first wave of health reform in the 1940s emphasized clinical and epidemiological research. Health systems research was not encouraged in a context of rapid economic development and an authoritarian regime. In contrast, health systems research was given a privileged place with the second wave of health reforms in the 1980s, which addressed health system coordination, decentralization and the universal right to health in a context of a deep economic crisis. The third wave of health reforms between 2003 and 2006 was based on the health system models proposed through research in the 90s. The credibility gained by research institutions was critical to ensure government uptake. Research influence can be traced through the role it played in defining a problem, in designing innovative insurance mechanisms and in establishing evaluation frameworks. It is argued that the Ministry of Health's budget increase of 56% between 2003 and 2006 and the reductions in inequity are pay-back to research investments since the 1980s. PMID:19793399

  7. Design, experimental and economic evaluation of a commercial-type solar dryer for production of high-quality hay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arinze, E.A.; Sokhansanj, S.; Schoenau, G.J.

    1998-03-01

    Design features, development, experimental functional performance and economic evaluation of an energy efficient solar energy dryer for commercial production of high-quality hay and processed forage products are presented. The solar hay dryer consists of an improved solar collector with selective coated aluminum absorber plate and spaced fins, and a drying shed connected to the collector by an insulated duct and having a perforated metal grate floor, swing-away plywood frames and polyethylene curtains for effectively sealing the hay stack, and a crawl space below the floor where a 3-hp in-line centrifugal fan is housed for air circulation by suction. In latemore » August and in early September, 1996, 160 small rectangular bales of alfalfa hay with about 25% bromegrass were successfully dried from 33% initial moisture content to 13%, and from 25% to 11% moisture in 4 and 3 days, respectively, under average weather conditions in Saskatoon, Saskatchewan, Canada. With about 18 m{sup 3}/min per tonne airflow, 10--15 C temperature rise above ambient was obtained during peak bright sunshine hours. Relatively high daily average collector efficiency of 76%, high drying effectiveness, drying uniformity, uniform air distribution and tight sealing of the stack were achieved which resulted in an attractive green color of hay, no mold growth on hay, and an overall system drying efficiency of about 79%. Compared to a conventional natural gas drying system or field-drying method, the payback period on extra investment costs recovered through drying cost savings of $3/t to $6/t or through over two times higher prices for high-quality hay produced by the solar drying system may be just one or two years, respectively.« less

  8. The economic value of an investment in physiotherapy education: a net present value analysis.

    PubMed

    Rivers, George; Foo, Jonathan; Ilic, Dragan; Nicklen, Peter; Reeves, Scott; Walsh, Kieran; Maloney, Stephen

    2015-07-01

    What is the economic value for an individual to invest in physiotherapy undergraduate education in Australia? How is this affected by increased education costs or decreased wages? A cost-benefit analysis using a net present value (NPV) approach was conducted and reported in Australian dollars. In relation to physiotherapy education, the NPV represents future earnings as a physiotherapist minus the direct and indirect costs in obtaining the degree. Sensitivity analyses were conducted to consider varying levels of experience, public versus private sector, and domestic versus international student fees. Comparable calculations were made for educational investments in medicine and nursing/midwifery. Assuming an expected discount rate of 9.675%, investment in education by domestic students with approximately 34 years of average work experience yields a NPV estimated at $784,000 for public sector physiotherapists and $815,000 for private sector therapists. In relation to international students, the NPV results for an investment and career as a physiotherapist is estimated at $705,000 in the public sector and $736,000 in the private sector. With an approximate payback period of 4 years, coupled with strong and positive NPV values, physiotherapy education in Australia is a financially attractive prospect and a viable value proposition for those considering a career in this field. Copyright © 2015 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  9. Thermal Properties of Green Fuel Briquettes from Residue Corncobs Materials Mixed Macadamia Shell Charcoal Powder

    NASA Astrophysics Data System (ADS)

    Teeta, Suminya; Nachaisin, Mali; Wanish, Suchana

    2017-09-01

    The objective of this research was to produce green fuel briquettes from corncobs by adding macadamia shell charcoal powder. The study was sectioned into 3 parts: 1) Quality improvement of green fuel briquettes by adding macadamia; 2) Fuel property analysis based on ASTM standards and thermal fuel efficiency; and 3) Economics appropriateness in producing green fuel briquettes. This research produced green fuel briquettes using the ratio of corncobs weight and macadamia shell charcoal powder in 100:0 90:10 80:20 70:30 60:40 and 50:50 and pressing in the cold briquette machine. Fuel property analysis showed that green fuel briquettes at the ratio 50:50 produced maximum heating values at 21.06 Megajoule per kilogram and briquette density of 725.18 kilograms per cubic meter, but the percent of moisture content, volatile matter, ash, and fixed carbon were 10.09, 83.02, 2.17 and 4.72 respectively. The thermal efficiency of green fuel briquettes averaged 20.22%. Economics appropriateness was most effective where the ratio of corncobs weight to macadamia shell charcoal powder was at 50:50 which accounted for the cost per kilogram at 5.75 Baht. The net present value was at 1,791.25 Baht. Internal rate of return was at 8.62 and durations for a payback period of investment was at 1.9 years which was suitable for investment.

  10. Economical and financial analysis of lamb finishing fed with diets formulated according to the NRC (1985) and the NRC (2007).

    PubMed

    Rogério, Marcos Cláudio Pinheiro; de Castro, Eliane Minervina; Martins, Espedito Cezário; Monteiro, Jomar Patrício; Silva, Kleibe de Moraes; Cândido, Magno José Duarte; Gomes, Tereza Cristina Lacerda; Bloc, Antoine Francis Roux; de Vasconcelos, Angela Maria; Leite, Eneas Reis; Costa, Hélio Henrique Araújo

    2013-01-01

    This study compares both versions of the nutritional requirement system determined by the National Research Council (NRC) version 1985 (NRC85) and NRC version 2007 (NRC07), for finishing lambs in feedlots. Nineteen crossbred lambs were divided in four groups representing four experimental treatments: one diet according to NRC85 and three diets according to NRC07. The diets recommended by NRC07 considers crude protein intake relative to ruminal undegradable protein at 20, 40, and 60 % levels (NRC07/20, NRC07/40, and NRC07/60). Diets were composed of Brazilian semi-arid native grass silage, soybean meal, corn, annatto byproduct, and limestone. Purchases and sales of lambs were done according to average market prices in Brazil. The economic indicators considered pointed that all treatments were viable but NRC07/20 and NRC07/60 were more profitable with similar net present values (NPVs) and internal return rates (IRRs). NRC07/20 was the best option showing an IRR of 17.20 % and a payback period (PP) of 5.07 considering a fixed annual interest rate of 6 %. Sensitivity analysis considering a 10 % raise in variable costs showed negative NPVs, IRRs inferior to the opportunity cost rates adopted and PPs that exceeded the planning horizon of 7 years for both NRC85 and NRC07/40.

  11. Feasibility model study for Blumbangreksa product model based on lean startup method

    NASA Astrophysics Data System (ADS)

    Pakpahan, A. K.; Dewobroto, W. S.; Pratama, R. Y.

    2017-12-01

    Based on the data from Ministry of Maritime Affairs and Fisheries in 2015, the productivity of shrimp farmers in Indonesia is still below China, India and Thailand, because of the low survival rate of shrimp seeds were planted in Indonesia. Water quality factors become a significant factor that increasesthe survival rate of shrimp seeds plantation, therefore team of PT. Atnic EkoteknoWicaksana create a tool called Blumbangreksa that able to monitor water quality of shrimp farms, measure temperature, salinity, pH, DO (dissolved oxygen), TDS (total dissolve solid) in water and moist air over the surface of the water and GSM -based and Internet of things. Based on the research results, unique value proposition of Blumbangreksa products is the measurement result of water quality are accurate, real-time measurements, based on Internet of things and have the ability measurements at once. Based on the feasibility study using the opportunity assessment of Marty Cagan, it can be seen that the product has fulfilled ten elements of assessment opportunity, so Blumbangreksa products are considered feasible. Initial investment fund of Blumbangreksa products is Rp 1,369,856,574, with profitability index of 1:51 and average breakeven products each year as many as 18 products are sold, and the payback period for 4 years and 2 months, therefore the business of Blumbangreksa product is feasible.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radhi, Hassan

    Developments in the design and manufacture of photovoltaic cells have recently been a growing concern in the UAE. At present, the embodied energy pay-back time (EPBT) is the criterion used for comparing the viability of such technology against other forms. However, the impact of PV technology on the thermal performance of buildings is not considered at the time of EPBT estimation. If additional energy savings gained over the PV system life are also included, the total EPBT could be shorter. This paper explores the variation of the total energy of building integrated photovoltaic systems (BiPV) as a wall cladding systemmore » applied to the UAE commercial sector and shows that the ratio between PV output and saving in energy due to PV panels is within the range of 1:3-1:4. The result indicates that for the southern and western facades in the UAE, the embodied energy pay-back time for photovoltaic system is within the range of 12-13 years. When reductions in operational energy are considered, the pay-back time is reduced to 3.0-3.2 years. This study comes to the conclusion that the reduction in operational energy due to PV panels represents an important factor in the estimation of EPBT. (author)« less

  13. Guide to the economic analysis of community energy systems

    NASA Astrophysics Data System (ADS)

    Pferdehirt, W. P.; Croke, K. G.; Hurter, A. P.; Kennedy, A. S.; Lee, C.

    1981-08-01

    This guidebook provides a framework for the economic analysis of community energy systems. The analysis facilitates a comparison of competing configurations in community energy systems, as well as a comparison with conventional energy systems. Various components of costs and revenues to be considered are discussed in detail. Computational procedures and accompanying worksheets are provided for calculating the net present value, straight and discounted payback periods, the rate of return, and the savings to investment ratio for the proposed energy system alternatives. These computations are based on a projection of the system's costs and revenues over its economic lifetimes. The guidebook also discusses the sensitivity of the results of this economic analysis to changes in various parameters and assumptions.

  14. Improving Motor and Drive System Performance – A Sourcebook for Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This sourcebook outlines opportunities to improve motor and drive systems performance. The sourcebook is divided into four main sections: (1) Motor and Drive System Basics: Summarizes important terms, relationships, and system design considerations relating to motor and drive systems. (2) Performance Opportunity Road Map: Details the key components of well-functioning motor and drive systems and opportunities for energy performance opportunities. (3) Motor System Economics: Offers recommendations on how to propose improvement projects based on corporate priorities, efficiency gains, and financial payback periods. (4) Where to Find Help: Provides a directory of organizations associated with motors and drives, as well asmore » resources for additional information, tools, software, videos, and training opportunities.« less

  15. Energy and life-cycle cost analysis of a six-story office building

    NASA Astrophysics Data System (ADS)

    Turiel, I.

    1981-10-01

    An energy analysis computer program, DOE-2, was used to compute annual energy use for a typical office building as originally designed and with several energy conserving design modifications. The largest energy use reductions were obtained with the incorporation of daylighting techniques, the use of double pane windows, night temperature setback, and the reduction of artificial lighting levels. A life-cycle cost model was developed to assess the cost-effectiveness of the design modifications discussed. The model incorporates such features as inclusion of taxes, depreciation, and financing of conservation investments. The energy conserving strategies are ranked according to economic criteria such as net present benefit, discounted payback period, and benefit to cost ratio.

  16. Design of solar systems in high-rise buildings

    NASA Astrophysics Data System (ADS)

    Kolosov, Alexander; Chudinov, Dmitry; Yaremenko, Sergey

    2018-03-01

    Nowadays, the renovation program is being implemented in the megapolises of Russia. Innovative high-rise buildings are built instead of morally and physically obsolete houses, where non-traditional renewable energy sources are used to the fullest extent, under the effect of which they are located. The possibility to use solar systems with variation of their design parameters is considered. It is established that solar systems have high technical potential. The share of heat load, that is provided by using solar energy, varies from 4 to 84% depending on the time of the year. Economic indicators restrain the use of such panels. The payback period is about 8 years at the current cost for thermal energy.

  17. Energy analysis of coal, fission, and fusion power plants

    NASA Astrophysics Data System (ADS)

    Tsoulfanidis, N.

    1981-04-01

    The method of net energy analysis has been applied to coal, fission, and fusion power plants. Energy consumption over the lifetime of the plants has been calculated for construction, operation and maintenance, fuel, public welfare, and land use and restoration. Thermal and electric energy requirements were obtained separately for each energy consuming sector. The results of the study are presented in three ways: total energy requirements, energy gain ratio, and payback periods. All three types of power plants are net producers of energy. The coal and fusion power plants are superior to fission plants from the energy efficiency point of view. Fission plants will improve considerably if the centrifuge replaces the gaseous diffusion as a method of enrichment.

  18. Integrated alternative energy systems for use in small communities

    NASA Astrophysics Data System (ADS)

    Thornton, J.

    1982-01-01

    This paper summarizes the principles and conceptual design of an integrated alternative energy system for use in typical farming communities in developing countries. A system is described that, utilizing the Sun and methane produced from crop waste, would supply sufficient electric and thermal energy to meet the basic needs of villagers for water pumping, lighting, and cooking. The system is sized to supply enough pumping capacity to irrigate 101 ha (249 acres) sufficiently to optimize annual crop yields for the community. Three economic scenarios were developed, showing net benefits to the community of $3,578 to $15,547 anually, payback periods of 9.5 to 20 years, and benefit-to-cost ratios of 1.1 to 1.9.

  19. Comparative evaluation of three alternative power cycles for waste heat recovery from the exhaust of adiabatic diesel engines

    NASA Technical Reports Server (NTRS)

    Bailey, M. M.

    1985-01-01

    Three alternative power cycles were compared in application as an exhaust-gas heat-recovery system for use with advanced adiabatic diesel engines. The power cycle alternatives considered were steam Rankine, organic Rankine with RC-1 as the working fluid, and variations of an air Brayton cycle. The comparison was made in terms of fuel economy and economic payback potential for heavy-duty trucks operating in line-haul service. The results indicate that, in terms of engine rated specific fuel consumption, a diesel/alternative-power-cycle engine offers a significant improvement over the turbocompound diesel used as the baseline for comparison. The maximum imporvement resulted from the use of a Rankine cycle heat-recovery system in series with turbocompounding. The air Brayton cycle alternatives studied, which included both simple-cycle and compression-intercooled configurations, were less effective and provided about half the fuel consumption improvement of the Rankine cycle alternatives under the same conditions. Capital and maintenance cost estimates were also developed for each of the heat-recovery power cycle systems. These costs were integrated with the fuel savings to identify the time required for net annual savings to pay back the initial capital investment. The sensitivity of capital payback time to arbitrary increases in fuel price, not accompanied by corresponding hardware cost inflation, was also examined. The results indicate that a fuel price increase is required for the alternative power cycles to pay back capital within an acceptable time period.

  20. Performance of a large building rainwater harvesting system.

    PubMed

    Ward, S; Memon, F A; Butler, D

    2012-10-15

    Rainwater harvesting is increasingly becoming an integral part of the sustainable water management toolkit. Despite a plethora of studies modelling the feasibility of the utilisation of rainwater harvesting (RWH) systems in particular contexts, there remains a significant gap in knowledge in relation to detailed empirical assessments of performance. Domestic systems have been investigated to a limited degree in the literature, including in the UK, but there are few recent longitudinal studies of larger non-domestic systems. Additionally, there are few studies comparing estimated and actual performance. This paper presents the results of a longitudinal empirical performance assessment of a non-domestic RWH system located in an office building in the UK. Furthermore, it compares actual performance with the estimated performance based on two methods recommended by the British Standards Institute - the Intermediate (simple calculations) and Detailed (simulation-based) Approaches. Results highlight that the average measured water saving efficiency (amount of mains water saved) of the office-based RWH system was 87% across an 8-month period, due to the system being over-sized for the actual occupancy level. Consequently, a similar level of performance could have been achieved using a smaller-sized tank. Estimated cost savings resulted in capital payback periods of 11 and 6 years for the actual over-sized tank and the smaller optimised tank, respectively. However, more detailed cost data on maintenance and operation is required to perform whole life cost analyses. These findings indicate that office-scale RWH systems potentially offer significant water and cost savings. They also emphasise the importance of monitoring data and that a transition to the use of Detailed Approaches (particularly in the UK) is required to (a) minimise over-sizing of storage tanks and (b) build confidence in RWH system performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. A field demonstration of energy conservation using occupancy sensor lighting control in equipment rooms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dagle, J.E.

    1992-09-01

    The Pacific Northwest Laboratory identified energy savings potential of automatic equipment-room lighting controls, which was demonstrated by the field experiment described in this report. Occupancy sensor applications have gained popularity in recent years due to improved technology that enhances reliability and reduces cost. Automatic lighting control using occupancy sensors has been accepted as an energy-conservation measure because it reduces wasted lighting. This study focused on lighting control for equipment rooms, which have inherent conditions ideal for automatic lighting control, i.e., an area which is seldom occupied, multiple users of the area who would not know if others are in themore » room when they leave, and high lighting energy intensity in the area. Two rooms were selected for this study: a small equipment room in the basement of the 337 Building, and a large equipment area in the upper level of the 329 Building. The rooms were selected to demonstrate the various degrees of complexity which may be encountered in equipment rooms throughout the Hanford Site. The 337 Building equipment-room test case demonstrated a 97% reduction in lighting energy consumption, with an annual energy savings of $184. Including lamp-replacement savings, a total savings of $306 per year is offset by an initial installation cost of $1,100. The installation demonstrates a positive net present value of $2,858 when the lamp-replacement costs are included in a life-cycle analysis. This also corresponds to a 4.0-year payback period. The 329 Building equipment-room installation resulted in a 92% reduction in lighting energy consumption. This corresponds to annual energy savings of $1,372, and a total annual savings of $2,104 per year including lamp-replacement savings. The life-cycle cost analysis shows a net present value of $15,855, with a 5.8-year payback period.« less

  2. Wastewater recycling and heat reclamation project: Red Lion Central Laundry, Portland, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlick, T.F.; Halverson, M.A.; Ledbetter, M.R.

    1997-06-01

    This report discusses water, energy, and cost savings that can be achieved in a commercial laundry through the use of a wastewater recycling and heat recovery system. Cost savings are achieved through reductions in water use, reduction in sewage charges (typically based on water use), reductions in water heating energy, and potential reductions in water treatment chemicals because the recycled water has already been treated with soaps and conditioners. A recovery system saves water by recycling wash water that would normally be dumped into the city sewage system. Recycling the wash water produces considerable energy savings because the recycled watermore » has a higher temperature than fresh water. As a result, a hot water heater consumes less energy to heat the recycled water. The demonstration project discussed in this report was based in a large commercial laundry in Portland, Oregon. The laundry serves a large hotel/motel chain and processes an average of 25,000 pounds of laundry per day. A wastewater recovery system using a membrane microfiltration unit (MFU) was installed in the laundry in September 1995. Time series data of the water and energy consumption of the laundry were taken before and after installation of the MFU. Energy savings were measured by performing a thermal energy balance around the washing machines. Water savings were calculated by metering volumetric flow rates. After a period of approximately five months, the MFU has achieved final results of 52 percent savings in water consumption and 44 percent savings in energy to heat water. This five-month period represents a learning curve during which several small technical improvements were made to the MFU and laundry staff adjusted laundry operations to maximize the benefits of the MFU. An economic analysis discusses the impact of capital investment, daily consumption, and local utility rates on the payback period.« less

  3. Resource engineering and economic studies for direct application of geothermal energy. Draft final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-12-01

    The feasibility of utilizing geothermal energy at a selected plant in New York State was studied. Existing oil and gas records suggests that geothermal fluid is available in the target area and based on this potential. Friendship Dairies, Inc., Friendship, NY, was selected as a potential user of geothermal energy. Currently natural gas and electricity are used as its primary energy sources. Six geothermal system configurations were analyzed based on replacement of gas or oil-fired systems for producing process heat. Each system was evaluated in terms of Internal Rate of Return on Investment (IRR), and simple payback. Six system configurationsmore » and two replaced fuels, representative of a range of situations found in the state, are analyzed. Based on the potential geothermal reserves at Friendship, each of the six system configurations are shown to be economically viable, compared to continued gas or oil-firing. The Computed IRR's are all far in excess of projected average interest rates for long term borrowings: approximately 15% for guarantee backed loans or as high as 20% for conventional financing. IRR is computed based on the total investment (equity plus debt) and cash flows before financing costs, i.e., before interest expense, but after the tax benefit of the interest deduction. The base case application for the Friendship analysis is case B/20 yr-gas which produces an IRR of 28.5% and payback of 3.4 years. Even better returns could be realized in the cases of oil-avoidance and where greater use of geothermal energy can be made as shown in the other cases considered.« less

  4. When perfectly HLA-matched kidneys are refused for transplant: implications for a national cooperative sharing system.

    PubMed

    Ellison, M D; Breen, T J; Davies, D B; Edwards, E B; Mahoney, R J; Daily, O P; Norman, D J

    1996-11-01

    The transplant community attempts to maximize overall renal graft survival rates through nationwide sharing of perfectly-matched cadaveric kidneys. Although the number of such transplants is determined annually, the number available but not transplanted has never been assessed. There has also been no verification of the widespread claim that kidneys transplanted as paybacks for perfect matches are inferior. From records of the United Network for Organ Sharing, a complete accounting of six-antigen-matched kidney disposition was obtained, including a frequency distribution of reasons for refusal given when kidneys were refused for matched patients. Actuarial graft survival (GS) rates for matched, payback, and other cadaveric renal transplants were determined. Of the six-antigen-matched kidneys available, 97 percent were transplanted; 71 percent of those were accepted for matched patients. The two-year GS rate for matched patients was 84 percent, significantly higher than that for kidneys available for matched patients but transplanted into other patients (71.3 percent) and that for all other cadaveric kidneys (75.5 percent). Most reasons for refusal were related to donor quality. Kidneys refused for such reasons showed a 67.7 percent two-year GS rate in nonmatched patients and the highest rates of acute and chronic rejection and primary failure. The two-year GS rate for kidneys accepted as paybacks for matched kidneys (75.7 percent) was equivalent to that for all non-matched cadaveric kidneys (75.5 percent). If all normal-quality grafts refused for perfectly matched patients during 1990 through 1992 had been accepted for those patients, the number of transplants with typically superior survival rates could have increased by 25 percent, from 1,365 to 1,704. The payback requirement of the United Network for Organ Sharing does not seem to reduce the overall benefits of sharing perfectly matched kidneys nationwide.

  5. Walking beam furnace well-way slot covers at Rouge Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, F. Jr.; Meinzinger, A.D.; Faust, C.H.

    1993-07-01

    Rouge Steel's 68-in. hot strip mill is served by three walking beam slab reheat furnaces. The first two were commissioned in 1974 and the third was installed in 1980. During the period 1979 to 1981, an intensive plant-wide energy management program to reduce energy consumption was undertaken. A major part of that program involved a comprehensive upgrading of refractory and insulation systems utilized in the walking beam reheat furnaces. A durable system for reducing heat losses through the well-way floor openings associated with walking beam slab reheat furnaces has, in addition to 4 to 5% savings in fuel consumption, reducedmore » maintenance costs. Payback is achieved in four to five months.« less

  6. The Economics of Private Sector R and D Decisionmaking in Aeronautics

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Information which can be used in planning to insure commercial research and technology programs which are complementary to internally financed private sector activities are presented. The main concern is to identify the characteristics of productive projects in which firms are unlikely to invest. It is shown that: (1) if it is difficult to assess the commercial relevance of an R&D project or it it is characterized by high technical risk, or a relatively long payback period, private funding will be unlikely; and (2) if a project is large relative to the size of the firm, it is unlikely to be funded in the early stages of the R&D process. Firms tend to underinvest in projects with these characteristics.

  7. Congeneration feasibility: Otis Elevator Company and Polychrome Corporation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, H.

    1982-05-01

    This report summarizes an investigation of the technical and economic feasibility of cogenerating electric and thermal power at two manufacturing plants (Otis Elevator Company and Polychrome Corporation) located on neighboring properties in Yonkers, NY. Existing electrical- and steam-producing equipment and energy consumption date are summarized. Alternative cases examined include electrical energy generation, electrical energy generation with waste heat recovery and a combined cycle case. Also reported are life cycle cost economic evaluations including simple payback period and return-on-investment indices. While it was concluded that cogeneration of heat and electricity at these industrial plant sites would not be economically viable, thismore » detailed study provides valuable insight into the types of problems encountered when considering cogeneration feasibility.« less

  8. Energy conservation for housing: A workbook

    NASA Astrophysics Data System (ADS)

    1982-05-01

    Multifamily housing project managers can reduce their energy costs from 30 to 60 percent by capitalizing on a variety of energy conservation opportunities (ECO's) identified in HUD research on the physical condition of public housing stock. This workbook prepares managers for this planning and for making individualized energy audits. It provides all the materials they need to proceed, including analysis sheets for calculating costs - benefit and payback periods for each of the 50 ECO's described. The ECO's listed all into four general categories: architectural improvements to the energy design of the building envelope; heating system ECO's to increase energy efficiency; secondary ECO's related to the domestic water supply, air conditioning systems, and central laundry equipment; and electric system ECO's reducing utility surcharges and increasing light bulb efficiency.

  9. Data on electrical energy conservation using high efficiency motors for the confidence bounds using statistical techniques.

    PubMed

    Shaikh, Muhammad Mujtaba; Memon, Abdul Jabbar; Hussain, Manzoor

    2016-09-01

    In this article, we describe details of the data used in the research paper "Confidence bounds for energy conservation in electric motors: An economical solution using statistical techniques" [1]. The data presented in this paper is intended to show benefits of high efficiency electric motors over the standard efficiency motors of similar rating in the industrial sector of Pakistan. We explain how the data was collected and then processed by means of formulas to show cost effectiveness of energy efficient motors in terms of three important parameters: annual energy saving, cost saving and payback periods. This data can be further used to construct confidence bounds for the parameters using statistical techniques as described in [1].

  10. Comparative environmental and economic analysis of conventional and nanofluid solar hot water technologies.

    PubMed

    Otanicar, Todd P; Golden, Jay S

    2009-08-01

    This study compares environmental and economic impacts of using nanofluids to enhance solar collector efficiency as compared to conventional solar collectors for domestic hotwater systems. Results show that for the current cost of nanoparticles the nanofluid based solar collector has a slightly longer payback period but at the end of its useful life has the same economic savings as a conventional solar collector. The nanofluid based collector has a lower embodied energy (approximately 9%) and approximately 3% higher levels of pollution offsets than a conventional collector. In addition if 50% penetration of residential nanofluid based solar collector systems for hot water heating could be achieved in Phoenix, Arizona over 1 million metric tons of CO2 would be offset per year.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D.; Munk, Jeffrey D.; Gehl, Anthony C.

    The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming frommore » reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.« less

  12. PAYBACK Act

    THOMAS, 111th Congress

    Rep. Space, Zachary T. [D-OH-18

    2009-11-04

    House - 12/04/2009 Referred to the Subcommittee on Border, Maritime, and Global Counterterrorism. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  13. Experimental Study on Productivity Performance of Household Combined Thermal Power and Biogas System in Northwest China

    PubMed Central

    Zhen, Xiaofei; Osman, Yassir Idris Abdalla; Feng, Rong; Si, Zetian

    2018-01-01

    Ample quantities of solar and local biomass energy are available in the rural regions of northwest China to satisfy the energy needs of farmers. In this work, low-temperature solar thermal collectors, photovoltaic solar power generators, and solar-powered thermostatic biogas digesters were combined to create a heat, electricity, and biogas cogeneration system and were experimentally studied through two buildings in a farming village in northwestern China. The results indicated that the floor heater had the best heating effect. And the fraction of the energy produced by the solar elements of the system was 60.3%. The photovoltaic power-generation system achieved photovoltaic (PV) conversion efficiencies of 8.3% and 8.1% during the first and second season, respectively. The intrinsic power consumption of the system was 143.4 kW·h, and 115.7 kW·h of electrical power was generated by the system in each season. The average volume of biogas produced daily was approximately 1.0 m3. Even though the ambient temperature reached −25°C, the temperature of the biogas digester was maintained at 27°C ± 2 for thermostatic fermentation. After optimization, the energy-saving rate improved from 66.2% to 85.5%. The installation reduced CO2 emissions by approximately 27.03 t, and the static payback period was 3.1 yr. Therefore, the system is highly economical, energy efficient, and beneficial for the environment. PMID:29862289

  14. Experimental Study on Productivity Performance of Household Combined Thermal Power and Biogas System in Northwest China.

    PubMed

    Kang, Jian; Li, Jinping; Zhen, Xiaofei; Osman, Yassir Idris Abdalla; Feng, Rong; Si, Zetian

    2018-01-01

    Ample quantities of solar and local biomass energy are available in the rural regions of northwest China to satisfy the energy needs of farmers. In this work, low-temperature solar thermal collectors, photovoltaic solar power generators, and solar-powered thermostatic biogas digesters were combined to create a heat, electricity, and biogas cogeneration system and were experimentally studied through two buildings in a farming village in northwestern China. The results indicated that the floor heater had the best heating effect. And the fraction of the energy produced by the solar elements of the system was 60.3%. The photovoltaic power-generation system achieved photovoltaic (PV) conversion efficiencies of 8.3% and 8.1% during the first and second season, respectively. The intrinsic power consumption of the system was 143.4 kW·h, and 115.7 kW·h of electrical power was generated by the system in each season. The average volume of biogas produced daily was approximately 1.0 m 3 . Even though the ambient temperature reached -25°C, the temperature of the biogas digester was maintained at 27°C ± 2 for thermostatic fermentation. After optimization, the energy-saving rate improved from 66.2% to 85.5%. The installation reduced CO 2 emissions by approximately 27.03 t, and the static payback period was 3.1 yr. Therefore, the system is highly economical, energy efficient, and beneficial for the environment.

  15. Thermal treatment of medical waste in a rotary kiln.

    PubMed

    Bujak, J

    2015-10-01

    This paper presents the results of a study of an experimental system with thermal treatment (incineration) of medical waste conducted at a large complex of hospital facilities. The studies were conducted for a period of one month. The processing system was analysed in terms of the energy, environmental and economic aspects. A rotary combustion chamber was designed and built with the strictly assumed length to inner diameter ratio of 4:1. In terms of energy, the temperature distribution was tested in the rotary kiln, secondary combustion (afterburner) chamber and heat recovery system. Calorific value of medical waste was 25.0 MJ/kg and the thermal efficiency of the entire system equalled 66.8%. Next, measurements of the pollutant emissions into the atmosphere were performed. Due to the nature of the disposed waste, particular attention was paid to the one-minute average values of carbon oxide and volatile organic compounds as well as hydrochloride, hydrogen fluoride, sulphur dioxide and total dust. Maximum content of non-oxidized organic compounds in slag and bottom ash were also verified during the analyses. The best rotary speed for the combustion chamber was selected to obtain proper afterburning of the bottom slag. Total organic carbon content was 2.9%. The test results were used to determine the basic economic indicators of the test system for evaluating the profitability of its construction. Simple payback time (SPB) for capital expenditures on the implementation of the project was 4 years. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Hoeschele, E. Weitzel

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYSmore » model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  17. Efficiency of overhead ceiling lifts in reducing musculoskeletal injury among carers working in long-term care institutions.

    PubMed

    Alamgir, Hasanat; Yu, Shicheng; Fast, Catherine; Hennessy, Stephanie; Kidd, Catherine; Yassi, Annalee

    2008-05-01

    A longitudinal study was conducted in three long-term care facilities to evaluate the effectiveness and cost benefit of overhead lifts in reducing the risk of musculoskeletal injury among healthcare workers. Analysis of injury trends spanning 6 years before intervention (1996-2001) and 4 years after intervention (2002-2005) found a significant and sustained decrease in workers' compensation claims per number of beds and in working days lost per bed. The payback period was estimated under various assumptions and varied from 6.3 to 6.2 years if only direct claim-cost savings were included, and from 2.06 to 3.20 years when indirect savings were added. The significant reductions in injury rates and compensation claims support intervention with overhead ceiling lifts. A more comprehensive evaluation of such programmes should incorporate in the analysis important variables such as staffing ratios, job stresses, injury reporting systems and compensation policies during the study period.

  18. Alterations of chemical composition, construction cost and payback time in needles of Masson pine (Pinus massoniana L.) trees grown under pollution.

    PubMed

    Liu, Nan; Guan, Lan-Lan; Sun, Fang-Fang; Wen, Da-Zhi

    2014-07-01

    Previous studies show that Masson pine (Pinus massoniana L.) stands grown at the industrially-polluted site have experienced unprecedented growth decline, but the causal mechanisms are poorly understood. In this study, to understand the mechanisms of growth decline of Mason pine strands under pollution stresses, we determined the reactive oxygen species levels and chemical composition of the current-year (C) and one-year-old (C + 1) needles, and calculated the needle construction costs (CCmass) of Masson pine trees grown at an industrially-polluted site and an unpolluted remote site. Pine trees grown at the polluted site had significantly higher levels of hydroxyl radical and superoxide anion in their needles than those grown at the unpolluted site, and the former trees eventually exhibited needle early senescence. The contents of lipids, soluble phenolics and lignins in C and C + 1 needles were significantly higher at the polluted site than at the unpolluted site, but the total amounts of non-construction carbohydrates were lower in non-polluted needles than in polluted needles. Elevated levels of the reactive oxygen species and early senescence in polluted needles together led to significant increases in CCmass and a longer payback time. We infer that the lengthened payback time and needle early senescence under pollution stress may reduce the Masson pine tree growth and consequently accelerate tree decline.

  19. Domestic refrigeration appliances in Poland: Potential for improving energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyers, S.; Schipper, L.; Lebot, B.

    1993-08-01

    This report is based on information collected from the main Polish manufacturer of refrigeration appliances. We describe their production facilities, and show that the energy consumption of their models for domestic sale is substantially higher than the average for similar models made in W. Europe. Lack of data and uncertainty about future production costs in Poland limits our evaluation of the cost-effective potential to increase energy efficiency, but it appears likely that considerable improvement would be economic from a societal perspective. Many design options are likely to have a simple payback of less than five years. We found that themore » production facilities are in need of substantial modernization in order to produce higher quality and more efficient appliances. We discuss policy options that could help to build a market for more efficient appliances in Poland and thereby encourage investment to produce such equipment.« less

  20. Low-Cost Phase Change Material for Building Envelopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abhari, Ramin

    2015-08-06

    A low-cost PCM process consisting of conversion of fats and oils to PCM-range paraffins, and subsequent “encapsulation” of the paraffin using conventional plastic compounding/pelletizing equipment was demonstrated. The PCM pellets produced were field-tested in a building envelope application. This involved combining the PCM pellets with cellulose insulation, whereby 33% reduction in peak heat flux and 12% reduction in heat gain was observed (average summertime performance). The selling price of the PCM pellets produced according to this low-cost process is expected to be in the $1.50-$3.00/lb range, compared to current encapsulated PCM price of about $7.00/lb. Whole-building simulations using corresponding PCMmore » thermal analysis data suggest a payback time of 8 to 16 years (at current energy prices) for an attic insulation retrofit project in the Phoenix climate area.« less

  1. Back to the Earth.

    ERIC Educational Resources Information Center

    Abnee, Conn

    1999-01-01

    Discusses how schools can use geothermal technology to conserve energy and save money. How geothermal climate control works and its payback are examined, and examples of development and use are highlighted. (GR)

  2. "Simplify, Simplify."

    ERIC Educational Resources Information Center

    Stump, William P.

    1983-01-01

    An integrated electronic system combines individual monitoring and control functions into one economical unit that earns a rapid payback by automatically managing and controlling energy usage, building systems, and security and maintenance tasks. (MLF)

  3. Mixing Appropriations and Private Financing to Meet Federal Energy Management Goals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shonder, John A

    2012-06-01

    This report compares several strategies for mixing appropriations and private financing in a typical federal agency that has identified $100 million in required energy conservation measures (ECMs) at its facilities. The analysis shows that in order to maximize savings and minimize overall life-cycle cost, the best strategy for the agency is to use private financing to fund as many of the ECMs as possible within the statutory maximum 25-year project term, beginning with the ECMs with the shortest paybacks. Available appropriations should either be applied to a privately financed project as a one-time payment from savings (i.e., as a buydownmore » ) or used to directly fund longer-payback ECMs that cannot be included in the privately financed project.« less

  4. Energy savings and cost-benefit analysis of the new commercial building standard in China

    DOE PAGES

    Zhao, Shanguo; Feng, Wei; Zhang, Shicong; ...

    2015-10-07

    In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less

  5. Energy savings and cost-benefit analysis of the new commercial building standard in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Shanguo; Feng, Wei; Zhang, Shicong

    In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less

  6. Development of an innovative solar absorber

    NASA Astrophysics Data System (ADS)

    Goodchild, Gavin

    Solar thermal systems have great potential to replace or reduce the dependence of conventional fossil fuel based heating technologies required for space and water heating. Specifically solar domestic hot water systems can contribute 50-75% of the annual thermal load. To date residential users have been slow to purchase and install systems, primarily due to the large monetary investment required to purchase and install a system. Recent innovations in materials design and manufacturing techniques, offer opportunities for the development of absorber plate designs that have the potential to reduce cost, increase efficiency and reduce payback periods. Consequently, this design study was conducted in conjunction with industrial partners to develop an improved absorber based on roll bond manufacturing that can be produced at reduced cost with comparable or greater thermal efficiency.

  7. Industrial Assessment Centers - Small Manufacturers Reduce Energy & Increase Productivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Since 1976, the Industrial Assessment Centers (IACs), administered by the US Department of Energy, have supported small and medium-sized American manufacturers to reduce energy use and increase their productivity and competitiveness. The 24 IACs, located at premier engineering universities around the country (see below), send faculty and engineering students to local small and medium-sized manufacturers to provide no-cost assessments of energy use, process performance and waste and water flows. Under the direction of experienced professors, IAC engineering students analyze the manufacturer’s facilities, energy bills and energy, waste and water systems, including compressed air, motors/pumps, lighting, process heat and steam. Themore » IACs then follow up with written energy-saving and productivity improvement recommendations, with estimates of related costs and payback periods.« less

  8. What are the potential benefits of including latent storage in common wallboard?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, T.K.; Tomlinson, J.J.

    1992-07-01

    Previous work has shown that wallboard can be successfully manufactured to contain up to 30% phase change material (PCM), or wax, thus enabling this common building material to serve as a thermal energy storage device. This material was analyzed for passive solar applications and found to save energy with a reasonable pay-back time period. Further evaluations of the wallboard are reported in this paper. This analysis looks at potential applications of PCM wallboard as a load management device and as a comfort enhancer. Results show that the wallboard is ineffective in modifying the comfort level but can provide significant loadmore » management relief with no energy penalty. Modifications to typical heating and air-conditioning control strategies were necessary for successful load management.« less

  9. What are the potential benefits of including latent storage in common wallboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, T.K.; Tomlinson, J.J.

    1992-01-01

    Previous work has shown that wallboard can be successfully manufactured to contain up to 30% phase change material (PCM), or wax, thus enabling this common building material to serve as a thermal energy storage device. This material was analyzed for passive solar applications and found to save energy with a reasonable pay-back time period. Further evaluations of the wallboard are reported in this paper. This analysis looks at potential applications of PCM wallboard as a load management device and as a comfort enhancer. Results show that the wallboard is ineffective in modifying the comfort level but can provide significant loadmore » management relief with no energy penalty. Modifications to typical heating and air-conditioning control strategies were necessary for successful load management.« less

  10. Business Case for a Micro-Combined Heat and Power Fuel Cell System in Commercial Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brooks, Kriston P.; Makhmalbaf, Atefe; Anderson, David M.

    2013-10-30

    Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and hot water with greater efficiency and lower emissions than alternative sources. These systems can be used either as baseload, grid-connected, or as off-the-grid power sources. This report presents a business case for CHP-FCSs in the range of 5 to 50 kWe. Systems in this power range are considered micro-CHP-FCS. For this particular business case, commercial applications rather than residential or industrial are targeted. To understand the benefits of implementing a micro-CHP-FCS, the characteristics that determine their competitive advantage must first be identified. Locations with high electricity pricesmore » and low natural gas prices are ideal locations for micro-CHP-FCSs. Fortunately, these high spark spread locations are generally in the northeastern area of the United States and California where government incentives are already in place to offset the current high cost of the micro-CHP-FCSs. As a result of the inherently high efficiency of a fuel cell and their ability to use the waste heat that is generated as a CHP, they have higher efficiency. This results in lower fuel costs than comparable alternative small-scale power systems (e.g., microturbines and reciprocating engines). A variety of markets should consider micro-CHP-FCSs including those that require both heat and baseload electricity throughout the year. In addition, the reliable power of micro-CHP-FCSs could be beneficial to markets where electrical outages are especially frequent or costly. Greenhouse gas emission levels from micro-CHP-FCSs are 69 percent lower, and the human health costs are 99.9 percent lower, than those attributed to conventional coal-fired power plants. As a result, FCSs can allow a company to advertise as environmentally conscious and provide a bottom-line sales advantage. As a new technology in the early stages of adoption, micro-CHP-FCSs are currently more expensive than alternative technologies. As the technology gains a foothold in its target markets and demand increases, the costs will decline in response to improved manufacturing efficiencies, similar to trends seen with other technologies. Transparency Market Research forecasts suggest that the CHP-FCS market will grow at a compound annual growth rate of greater than 27 percent over the next 5 years. These production level increases, coupled with the expected low price of natural gas, indicate the economic payback period will move to less than 5 years over the course of the next 5 years. To better understand the benefits of micro-CHP-FCSs, The U.S. Department of Energy worked with ClearEdge Power to install fifteen 5-kWe fuel cells in the commercial markets of California and Oregon. Pacific Northwest National Laboratory is evaluating these systems in terms of economics, operations, and their environmental impact in real-world applications. As expected, the economic analysis has indicated that the high capital cost of the micro-CHP-FCSs results in a longer payback period than typically is acceptable for all but early-adopter market segments. However, a payback period of less than 3 years may be expected as increased production brings system cost down, and CHP incentives are maintained or improved.« less

  11. 34 CFR 263.8 - What are the payback requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... participant performs. (Approved by the Office of Management and Budget under control number 1810-0580... for which training was actually received under the Professional Development program. (c) The cash...

  12. Product Assurance Targeted to Meet Mission Objectives

    NASA Technical Reports Server (NTRS)

    Mclaughlin, Diane

    1991-01-01

    Topics concerning the Common Lunar Lander for the Space Exploration Initiative are covered and include the following: product assurance tools and supports; project goals; and product assurance structured for optimal payback.

  13. Consequences of neglecting the interannual variability of the solar resource: A case study of photovoltaic power among the Hawaiian Islands

    DOE PAGES

    Bryce, Richard; Losada Carreno, Ignacio; Kumler, Andrew; ...

    2018-04-05

    The interannual variability of the solar irradiance and meteorological conditions are often ignored in favor of single-year data sets for modeling power generation and evaluating the economic value of photovoltaic (PV) power systems. Yet interannual variability significantly impacts the generation from one year to another of renewable power systems such as wind and PV. Consequently, the interannual variability of power generation corresponds to the interannual variability of capital returns on investment. The penetration of PV systems within the Hawaiian Electric Companies' portfolio has rapidly accelerated in recent years and is expected to continue to increase given the state's energy objectivesmore » laid out by the Hawaii Clean Energy Initiative. We use the National Solar Radiation Database (1998-2015) to characterize the interannual variability of the solar irradiance and meteorological conditions across the State of Hawaii. These data sets are passed to the National Renewable Energy Laboratory's System Advisory Model (SAM) to calculate an 18-year PV power generation data set to characterize the variability of PV power generation. We calculate the interannual coefficient of variability (COV) for annual average global horizontal irradiance (GHI) on the order of 2% and COV for annual capacity factor on the order of 3% across the Hawaiian archipelago. Regarding the interannual variability of seasonal trends, we calculate the COV for monthly average GHI values on the order of 5% and COV for monthly capacity factor on the order of 10%. We model residential-scale and utility-scale PV systems and calculate the economic returns of each system via the payback period and the net present value. We demonstrate that studies based on single-year data sets for economic evaluations reach conclusions that deviate from the true values realized by accounting for interannual variability.« less

  14. Consequences of neglecting the interannual variability of the solar resource: A case study of photovoltaic power among the Hawaiian Islands

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryce, Richard; Losada Carreno, Ignacio; Kumler, Andrew

    The interannual variability of the solar irradiance and meteorological conditions are often ignored in favor of single-year data sets for modeling power generation and evaluating the economic value of photovoltaic (PV) power systems. Yet interannual variability significantly impacts the generation from one year to another of renewable power systems such as wind and PV. Consequently, the interannual variability of power generation corresponds to the interannual variability of capital returns on investment. The penetration of PV systems within the Hawaiian Electric Companies' portfolio has rapidly accelerated in recent years and is expected to continue to increase given the state's energy objectivesmore » laid out by the Hawaii Clean Energy Initiative. We use the National Solar Radiation Database (1998-2015) to characterize the interannual variability of the solar irradiance and meteorological conditions across the State of Hawaii. These data sets are passed to the National Renewable Energy Laboratory's System Advisory Model (SAM) to calculate an 18-year PV power generation data set to characterize the variability of PV power generation. We calculate the interannual coefficient of variability (COV) for annual average global horizontal irradiance (GHI) on the order of 2% and COV for annual capacity factor on the order of 3% across the Hawaiian archipelago. Regarding the interannual variability of seasonal trends, we calculate the COV for monthly average GHI values on the order of 5% and COV for monthly capacity factor on the order of 10%. We model residential-scale and utility-scale PV systems and calculate the economic returns of each system via the payback period and the net present value. We demonstrate that studies based on single-year data sets for economic evaluations reach conclusions that deviate from the true values realized by accounting for interannual variability.« less

  15. Voluntary GHG reduction of industrial sectors in Taiwan.

    PubMed

    Chen, Liang-Tung; Hu, Allen H

    2012-08-01

    The present paper describes the voluntary greenhouse gas (GHG) reduction agreements of six different industrial sectors in Taiwan, as well as the fluorinated gases (F-gas) reduction agreement of the semiconductor and Liquid Crystal Display (LCD) industries. The operating mechanisms, GHG reduction methods, capital investment, and investment effectiveness are also discussed. A total of 182 plants participated in the voluntary energy saving and GHG reduction in six industrial sectors (iron and steel, petrochemical, cement, paper, synthetic fiber, and textile printing and dyeing), with 5.35 Mt reduction from 2004 to 2008, or 33% higher than the target goal (4.02 Mt). The reduction accounts for 1.6% annual emission or 7.8% during the 5-yr span. The petrochemical industry accounts for 49% of the reduction, followed by the cement sector (21%) and the iron and steel industry (13%). The total investment amounted to approximately USD 716 million, in which, the majority of the investment went to the modification of the manufacturing process (89%). The benefit was valued at around USD 472 million with an average payback period of 1.5 yr. Moreover, related energy saving was achieved through different approaches, e.g., via electricity (iron and steel), steam and oil consumption (petrochemical) and coal usage (cement). The cost for unit CO(2) reduction varies per industry, with the steel and iron industrial sector having the highest cost (USD 346 t(-1) CO(2)) compared with the average cost of the six industrial sectors (USD 134 t(-1) CO(2)). For the semiconductor and Thin-Film Transistor LCD industries, F-gas emissions were reduced from approximately 4.1 to about 1.7 Mt CO(2)-eq, and from 2.2 to about 1.1 Mt CO(2)-eq, respectively. Incentive mechanisms for participation in GHG reduction are also further discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Lesson Learned from Technical and Economic Performance Assessment and Benefit Evaluation of CHP-FCS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makhmalbaf, Atefe; Brooks, Kriston P.; Srivastava, Viraj

    2014-08-22

    Recent efforts and interest in combined heat and power (CHP) have increased with the momentum provided by the federal government support for penetration of CHP systems. Combined heat and power fuel cell systems (CHP-FCSs) provide consistent electrical power and utilize the heat normally wasted in power generation for useful heating or cooling with lower emissions compared to alternative sources. A recent study investigated the utilization of CHP-FCSs in the range of 5 to 50KWe in various commercial building types and geographic locations. Electricity, heating, and water heating demands were obtained from simulation of the U.S. Department of Energy (DOE) commercialmore » reference building models for various building types. Utility rates, cost of equipment, and system efficiency were used to examine economic payback in different scenarios. As a new technology in the early stages of adoption, CHP-FCSs are more expensive than alternative technologies, and the high capital cost of the CHP-FCSs results in a longer payback period than is typically acceptable for all but early-adopter market segments. However, the installation of these units as on-site power generators also provide several other benefits that make them attractive to building owners and operators. The business case for CHP-FCSs can be made more financially attractive through the provision of government incentives and when installed to support strategic infrastructure, such as military installations or data centers. The results presented in this paper intend to provide policy makers with information to define more customized incentives and tax credits based on a sample of building types and geographic locations in order to attract more business investment in this new technology.« less

  17. DEEP: Database of Energy Efficiency Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Tianzhen; Piette, Mary; Lee, Sang Hoon

    A database of energy efficiency performance (DEEP) is a presimulated database to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 10 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER [sic] prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones.more » DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air conditioning, plug loads, and domestic hot war. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center (NERSC) of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of the CEC PIER project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users' decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit.« less

  18. Direct application of geothermal energy at the L'eggs Product Plant, Las Cruces, New Mexico. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-02-01

    The study program to determine the feasibility of interfacing a potential geothermal resource of Dona Ana County, New Mexico L'eggs Product industrial process is discussed in this final report. Five separate sites were evaluated initially as to geothermal potential and technical feasibility. Preliminary analysis revealed that three sites were considered normal, but that two sites (about three miles from the L'eggs Plant) had very high shallow subsurface temperature gradients (up to 14.85/sup 0/F/100 ft). An initial engineering analysis showed that to meet the L'eggs plant temperature and energy requirements a geothermal fluid temperature of about 250/sup 0/F and 200 gpmmore » flow rate would be necessary. A brief economic comparison indicated that the L'eggs plant site and a geothermal site approximately four miles from the plant did merit further investigation. Detailed engineering and economic design and analysis of these two sites (including the drilling of an 1873 feet deep temperature gradient test hole at the L'eggs Plant) showed that development of the four mile distant site was technically feasible and was the more economic option. It was determined that a single-stage flash system interface design would be most appropriate for the L'eggs Plant. Approximately 39 billion Btu/yr of fossil fuel could be replaced with geothermal energy at the L'eggs facility for a total installed system cost of slightly over $2 million. The projected economic payback period was calculated to be 9.2 years before taxes. This payback was not considered acceptable by L'eggs Products, Inc., to merit additional design or construction work at this time.« less

  19. Economic and environmental analysis of standard, high efficiency, rainwater flushed, and composting toilets.

    PubMed

    Anand, C; Apul, D S

    2011-03-01

    The current sanitation technology in developed countries is based on diluting human excreta with large volumes of centrally provided potable water. This approach is a poor use of water resources and is also inefficient, expensive, and energy intensive. The goal of this study was to compare the standard sanitation technology (Scenario 1) with alternative technologies that require less or no potable water use in toilets. The alternative technologies considered were high efficiency toilets flushed with potable water (Scenario 2), standard toilets flushed with rainwater (Scenario 3), high efficiency toilets flushed with rainwater (Scenario 4), and composting toilets (Scenario 5). Cost, energy, and carbon implications of these five design scenarios were studied using two existing University of Toledo buildings. The results showed that alternative systems modeled in Scenarios 2, 4, and 5 were viable options both from an investment and an environmental performance perspective. High efficiency fixtures that use potable water (Scenario 2) is often the most preferred method in high efficiency buildings due to reduced water use and associated reductions in annual water and wastewater costs. However, the cost, energy, and CO(2)EE analyses all showed that Scenarios 4 and 5 were preferable over Scenario 2. Cost payback periods of scenarios 2, 4 and 5 were less than 10 years; in the future, increase in water and wastewater services would further decrease the payback periods. The centralized water and wastewater services have high carbon footprints; therefore if carbon footprint reduction is a primary goal of a building complex, alternative technologies that require less potable water and generate less wastewater can largely reduce the carbon footprint. High efficiency fixtures flushed with rainwater (Scenario 4) and composting toilets (Scenario 5) required considerably less energy than direct energy demands of buildings. However, the annual carbon footprint of these technologies was comparable to the annual carbon footprint from space heating. Similarly, the carbon savings that could be achieved from Scenario 4 or 5 were comparable to a recycling program that can be implemented in buildings. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Potential of Micro Hydroelectric Generator Embedded at 30,000 PE Effluent Discharge of Sewerage Treatment Plant

    NASA Astrophysics Data System (ADS)

    Che Munaaim, M. A.; Razali, N.; Ayob, A.; Hamidin, N.; Othuman Mydin, M. A.

    2018-03-01

    A micro hydroelectric generator is an energy conversion approach to generate electricity from potential (motion) energy to an electrical energy. In this research, it is desired to be implemented by using a micro hydroelectric generator which is desired to be embedded at the continuous flow of effluent discharge point of domestic sewerage treatment plant (STP). This research evaluates the potential of electricity generation from micro hydroelectric generator attached to 30,000 PE sewerage treatment plant. The power output obtained from calculation of electrical power conversion is used to identify the possibility of this system and its ability to provide electrical energy, which can minimize the cost of electric bill especially for the pumping system. The overview of this system on the practical application with the consideration of payback period is summarized. The ultimate aim of the whole application is to have a self-ecosystem electrical power generated for the internal use of STP by using its own flowing water in supporting the sustainable engineering towards renewable energy and energy efficient approach. The results shows that the output power obtained is lower than expected output power (12 kW) and fall beyond of the range of a micro hydro power (5kW - 100kW) since it is only generating 1.58 kW energy by calculation. It is also observed that the estimated payback period is longer which i.e 7 years to recoup the return of investment. A range of head from 4.5 m and above for the case where the flow shall at least have maintained at 0.05 m3/s in the selected plant in order to achieved a feasible power output. In conclusion, wastewater treatment process involves the flowing water (potential energy) especially at the effluent discharge point of STP is possibly harvested for electricity generation by embedding the micro hydroelectric generator. However, the selection of STP needs to have minimum 4.5 meter head with 0.05 m3/s of continuously flowing water to make it feasible to harvest.

  1. The School Advanced Ventilation Engineering Software (SAVES)

    EPA Pesticide Factsheets

    The School Advanced Ventilation Engineering Software (SAVES) package is a tool to help school designers assess the potential financial payback and indoor humidity control benefits of Energy Recovery Ventilation (ERV) systems for school applications.

  2. Field Test Evaluation of Conservation Retrofits of Low-Income, Single-Family Buildings in Wisconsin: Blower-Door-Directed Infiltration Reduction Procedure, Field Test Implementation and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gettings, M.B.

    A blower-door-directed infiltration retrofit procedure was field tested on 18 homes in south central Wisconsin. The procedure, developed by the Wisconsin Energy Conservation Corporation, includes recommended retrofit techniques as well as criteria for estimating the amount of cost-effective work to be performed on a house. A recommended expenditure level and target air leakage reduction, in air changes per hour at 50 Pascal (ACH50), are determined from the initial leakage rate measured. The procedure produced an average 16% reduction in air leakage rate. For the 7 houses recommended for retrofit, 89% of the targeted reductions were accomplished with 76% of themore » recommended expenditures. The average cost of retrofits per house was reduced by a factor of four compared with previous programs. The average payback period for recommended retrofits was 4.4 years, based on predicted energy savings computed from achieved air leakage reductions. Although exceptions occurred, the procedure's 8 ACH50 minimum initial leakage rate for advising retrofits to be performed appeared a good choice, based on cost-effective air leakage reduction. Houses with initial rates of 7 ACH50 or below consistently required substantially higher costs to achieve significant air leakage reductions. No statistically significant average annual energy savings was detected as a result of the infiltration retrofits. Average measured savings were -27 therm per year, indicating an increase in energy use, with a 90% confidence interval of 36 therm. Measured savings for individual houses varied widely in both positive and negative directions, indicating that factors not considered affected the results. Large individual confidence intervals indicate a need to increase the accuracy of such measurements as well as understand the factors which may cause such disparity. Recommendations for the procedure include more extensive training of retrofit crews, checks for minimum air exchange rates to insure air quality, and addition of the basic cost of determining the initial leakage rate to the recommended expenditure level. Recommendations for the field test of the procedure include increasing the number of houses in the sample, more timely examination of metered data to detect anomalies, and the monitoring of indoor air temperature. Though not appropriate in a field test of a procedure, further investigation into the effects of air leakage rate reductions on heating loads needs to be performed.« less

  3. Techno-Economic Analysis of Solar Water Heating Systems inTurkey.

    PubMed

    Ertekin, Can; Kulcu, Recep; Evrendilek, Fatih

    2008-02-25

    In this study, solar water heater was investigated using meteorological and geographical data of 129 sites over Turkey. Three different collector types were compared in terms of absorber material (copper, galvanized sheet and selective absorber). Energy requirement for water heating, collector performances, and economical indicators were calculated with formulations using observed data. Results showed that selective absorbers were most appropriate in terms of coverage rate of energy requirement for water-heating all over Turkey. The prices of selective, copper and galvanized absorber type's heating systems in Turkey were 740.49, 615.69 and 490.89 USD, respectively. While payback periods (PBPs) of the galvanized absorber were lower, net present values (NPVs) of the selective absorber were higher than the rest. Copper absorber type collectors did not appear to be appropriate based on economical indicators.

  4. Techno-Economic Analysis of Solar Water Heating Systems in Turkey

    PubMed Central

    Ertekin, Can; Kulcu, Recep; Evrendilek, Fatih

    2008-01-01

    In this study, solar water heater was investigated using meteorological and geographical data of 129 sites over Turkey. Three different collector types were compared in terms of absorber material (copper, galvanized sheet and selective absorber). Energy requirement for water heating, collector performances, and economical indicators were calculated with formulations using observed data. Results showed that selective absorbers were most appropriate in terms of coverage rate of energy requirement for water-heating all over Turkey. The prices of selective, copper and galvanized absorber type's heating systems in Turkey were 740.49, 615.69 and 490.89 USD, respectively. While payback periods (PBPs) of the galvanized absorber were lower, net present values (NPVs) of the selective absorber were higher than the rest. Copper absorber type collectors did not appear to be appropriate based on economical indicators. PMID:27879764

  5. Grid-connected distributed solar power systems

    NASA Astrophysics Data System (ADS)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  6. Status of Goldstone solar energy system study of the first Goldstone energy project

    NASA Technical Reports Server (NTRS)

    Lansing, F. L.

    1977-01-01

    The results reached by the DSN engineering section and private consultants in the review of the initial plan of the Golstone Energy Project are summarized. The main objectives were in the areas of energy conservation and the application of solar-driven systems for power and hydrogen generation. This summary will provide background data for management planning decisions both to the DSN engineering section and other organizations planning a similar program. The review showed that an add-on solar driven absorption refrigeration unit with its associated changes to the existing system was not cost-effective, having a payback period of 29 years. Similar economically unattractive results were found for both a solar-hydrogen and a wind-hydrogen generation plant. However, cutting the hydrogen generation linkage from this plant improved its economic feasibility.

  7. What are the potential benefits of including latent storage in common wallboard?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, T.K.; Tomlinson, J.J.

    1995-11-01

    Previous work has shown that wallboard can be successfully manufactured to contain up to 30% phase-change material (PCM), or wax, thus enabling this common building material to serve as a thermal energy storage device. The PCM wallboard was analyzed for passive solar applications and found to save energy with a reasonable payback time period of five years. Further evaluations of the wallboard are reported in this paper. This analysis looks at potential applications of PCM wallboard as a load management device and as a comfort enhancer. Results show that the wallboard is ineffective in modifying the comfort level but canmore » provide significant load management relief. In some applications the load management strategy also serves to save a small amount of energy, in others there is a small energy penalty.« less

  8. Performance and economic analysis of a plug and play regenerative brake for improving energy efficiency for traction elevators

    NASA Astrophysics Data System (ADS)

    Jeraputra, Chuttchaval; Tiptipakorn, Supun

    2017-05-01

    This paper presents performance and economic analysis of a plug and play regenerative brake for improving energy efficiency for traction elevators. The proposed regenerative brake recycles the energy loss of a dynamic brake and feeds into the grid while an elevator inverter is operating in the braking mode. According to field measurement of energy consumption, it reveals that the efficiency can be improved as much as 18%. The prototype of a regenerative brake 12 kW, 400V, 3ϕ is developed and tested on an elevator simulator. It is shown that it can transfer energy out of a DC capacitor before the dynamic brake kicks in. Further, an economic analysis is provided to carry out the payback period and the present worth equivalent to confirm economic feasibility.

  9. Advanced Sorbent Structure Recovery of REEs, Precious Metals and Other Valuable Metals from Geothermal Waters and Its Associated Technoeconomics

    DOE Data Explorer

    Addleman, Shane; Chouyyok, Wilaiwan; Palo, Daniel; Dunn, Brad M.; Brann, Michelle; Billingsley, Gary; Johnson, Darren; Nell, Kara M.

    2017-05-25

    This work evaluates, develops and demonstrates flexible, scalable mineral extraction technology for geothermal brines based upon solid phase sorbent materials with a specific focus upon rare earth elements (REEs). The selected organic and inorganic sorbent materials demonstrated high performance for collection of trace REEs, precious and valuable metals beyond commercially available sorbents. This report details the organic and inorganic sorbent uptake, performance, and collection efficiency results for La, Eu, Ho, Ag, Cu and Zn, as well as the characterization of these select sorbent materials. The report also contains estimated costs from an in-depth techno-economic analysis of a scaled up separation process. The estimated financial payback period for installing this equipment varies between 3.3 to 5.7 years depending on the brine flow rate of the geothermal resource.

  10. Multifamily Heat Pump Water Heater Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Weitzel, E.

    2017-03-03

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. Themore » TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  11. Multifamily Heat Pump Water Heater Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Weitzel, E.

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. Themore » TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  12. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYSmore » model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  13. Experimental and feasibility assessment of biogas production by anaerobic digestion of fruit and vegetable waste from Joburg Market.

    PubMed

    Masebinu, S O; Akinlabi, E T; Muzenda, E; Aboyade, A O; Mbohwa, C

    2018-05-01

    Substrate-induced instability of anaerobic digestion from fruit and vegetable waste (FVW) results in low biogas yield. In this study, substrate management through fruit to vegetable mix ratio in a two-stage semi-continuous digester was investigated as a pathway for optimality of yield. The experiment conducted over 105 days with 62.52 kg of FVWs sourced from Joburg Market, South Africa showed that a stable process was achieved at a fruit to vegetable waste mix ratio of 2.2:2.8. At this ratio, optimal organic loading rate ranged between 2.68 and 2.97 kg VS/m 3 -d which resulted in a specific biogas yield of 0.87 Nm 3 /kg VS with 57.58% methane on average. The results of the experimental study were used as a feasibility assessment for a full-scale 45 tonnes/d plant for Joburg Market considering three energy pathways. The plant will produce 1,605,455 Nm 3 /y of biogas with the potential for offsetting 15.2% of the Joburg Market energy demand. Conversion of all biogas to biomethane was the most economically attractive energy pathway with a net present value of $2,428,021, an internal rate of return of 16.90% and a simple payback period of 6.17 years. This route avoided the greenhouse gas emission of 12,393 tonnes CO 2 , eq. The study shows that the anaerobic digestion of FVWs as sole substrate is possible with financial and environmental attractiveness. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. An assessment of health research impact in Iran.

    PubMed

    Yazdizadeh, Bahareh; Majdzadeh, Reza; Janani, Leila; Mohtasham, Farideh; Nikooee, Sima; Mousavi, Abdmohammad; Najafi, Farid; Atabakzadeh, Maryam; Bazrafshan, Azam; Zare, Morteza; Karami, Manoochehr

    2016-07-26

    In recent years, Iran has made significant developments in the field of health sciences. However, the question is whether this considerable increase has affected public health. The research budget has always been negligible and unsustainable in developing countries. Hence, using the Payback Framework, we conducted this study to evaluate the impact of health research in Iran. By using a cross-sectional method and two-stage stratified cluster sampling, the projects were randomly selected from six medical universities. A questionnaire was designed according to the Payback Framework and completed by the principle investigators of the randomly selected projects. The response rate was 70.4%. Ten point twenty-four percent (10.24%) of the studies had been ordered by a knowledge user organization. The average number of articles published in journals per project was 0.96, and half of the studies had no articles published in Scopus. The results of 12% of the studies had been used in systematic review articles and the same proportion had been utilized in clinical or public health guidelines. The results of 5.3% of the studies had been implemented in the Health Ministry's policymaking. 62% of the studies were expected to affect health directly, 38% of them had been implemented, and among the latter 60% had achieved the expected results. Concerning the economic impacts, the most common expected impact was the reduction of 'days of work missed because of illness or disability' and impact on personal and health system costs. About 36% of these studies had been implemented, and 61% had achieved the expected impact. In most aspects, the status of research impact needs improvement. A comparison of Iran's ranking of knowledge creation and knowledge impact in the Global Innovation Index confirms these findings. The most important problems identified were, not conducting research based on national needs, and the lack of implementation of research results.

  15. Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-07-01

    The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for themore » laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  16. Profitability Analysis of Soybean Oil Processes.

    PubMed

    Cheng, Ming-Hsun; Rosentrater, Kurt A

    2017-10-07

    Soybean oil production is the basic process for soybean applications. Cash flow analysis is used to estimate the profitability of a manufacturing venture. Besides capital investments, operating costs, and revenues, the interest rate is the factor to estimate the net present value (NPV), break-even points, and payback time; which are benchmarks for profitability evaluation. The positive NPV and reasonable payback time represent a profitable process, and provide an acceptable projection for real operating. Additionally, the capacity of the process is another critical factor. The extruding-expelling process and hexane extraction are the two typical approaches used in industry. When the capacities of annual oil production are larger than 12 and 173 million kg respectively, these two processes are profitable. The solvent free approach, known as enzyme assisted aqueous extraction process (EAEP), is profitable when the capacity is larger than 17 million kg of annual oil production.

  17. Profitability Analysis of Soybean Oil Processes

    PubMed Central

    2017-01-01

    Soybean oil production is the basic process for soybean applications. Cash flow analysis is used to estimate the profitability of a manufacturing venture. Besides capital investments, operating costs, and revenues, the interest rate is the factor to estimate the net present value (NPV), break-even points, and payback time; which are benchmarks for profitability evaluation. The positive NPV and reasonable payback time represent a profitable process, and provide an acceptable projection for real operating. Additionally, the capacity of the process is another critical factor. The extruding-expelling process and hexane extraction are the two typical approaches used in industry. When the capacities of annual oil production are larger than 12 and 173 million kg respectively, these two processes are profitable. The solvent free approach, known as enzyme assisted aqueous extraction process (EAEP), is profitable when the capacity is larger than 17 million kg of annual oil production. PMID:28991168

  18. The relationship between reinforcement and gaming machine choice.

    PubMed

    Haw, John

    2008-03-01

    The present study assessed whether prior reinforcement experiences were related to gaming machine choice and the decision to change gaming machines during a session of gambling. Seventy undergraduate students (48 women, 22 men; mean age = 22.05 years) were presented with two visually identical simulated gaming machines in a practice phase. These simulated machines differed only in the rate of reinforcement. After the practice phase, participants were asked to choose a machine to play in the test phase and were allowed to change machines at will. Two measures of reinforcement were employed; frequency of wins and payback rate. Results indicated that neither measure of reinforcement was related to machine choice, but both were predictors of when participants changed machines. A post-hoc analysis of the 33 participants who changed machines during the test phase found a significant relationship between machine choice and prior reinforcement. For these participants, payback rate was significantly related to machine choice, unlike frequency of wins.

  19. General process improvements through pinch technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Linnhoff, B.; Polley, G.T.; Sahdev, V.

    1988-06-01

    Over the last ten years pinch technology has emerged as somewhat of a ''maverick'' development in the process design and energy conservation scene. Running contrary to general trends by taking the computer out of the loop and putting the engineer back in control, it has been questioned by some and welcomed by others. Regardless of persuasion, however, critics and advocates alike have largely failed to notice that pinch technology is more than an energy conservation tool. This is probably because soon after the advent of pinch technology in the 1970s, the process design scene became dominated by the oil crisis.more » Energy savings became the primary task of process designers and, therefore, the primary focus of the technology. Application during this period typically demonstrated energy cost savings in the range of 20 to 50 percent and payback periods of one year or less. Only recently have the other benefits of the technology reemerged. While it is true that pinch technology is essentially a heat-flow-based technique it is also true that it can be used to address a very diverse range of objectives.« less

  20. Functional analysis of the relative growth rate, chemical composition, construction and maintenance costs, and the payback time of Coffea arabica L. leaves in response to light and water availability.

    PubMed

    Cavatte, Paulo C; Rodríguez-López, Nélson F; Martins, Samuel C V; Mattos, Mariela S; Sanglard, Lílian M V P; Damatta, Fábio M

    2012-05-01

    In this study, the combined effects of light and water availability on the functional relationships of the relative growth rate (RGR), leaf chemical composition, construction and maintenance costs, and benefits in terms of payback time for Coffea arabica are presented. Coffee plants were grown for 8 months in 100% or 15% full sunlight and then a four-month water shortage was implemented. Plants grown under full sunlight were also transferred to shade and vice versa. Overall, most of the traits assessed were much more responsive to the availability of light than to the water supply. Larger construction costs (12%), primarily associated with elevated phenol and alkaloid pools, were found under full sunlight. There was a positive correlation between these compounds and the RGR, the mass-based net carbon assimilation rate and the carbon isotope composition ratio, which, in turn, correlated negatively with the specific leaf area. The payback time was remarkably lower in the sun than in shade leaves and increased greatly in water-deprived plants. The differences in maintenance costs among the treatments were narrow, with no significant impact on the RGR, and there was no apparent trade-off in resource allocation between growth and defence. The current irradiance during leaf bud formation affected both the specific leaf area and leaf physiology upon transferring the plants from low to high light and vice versa. In summary, sun-grown plants fixed more carbon for growth and secondary metabolism, with the net effect of an increased RGR.

  1. An economic evaluation comparison of solar water pumping system with engine pumping system for rice cultivation

    NASA Astrophysics Data System (ADS)

    Treephak, Kasem; Thongpron, Jutturit; Somsak, Dhirasak; Saelao, Jeerawan; Patcharaprakiti, Nopporn

    2015-08-01

    In this paper we propose the design and economic evaluation of the water pumping systems for rice cultivation using solar energy, gasoline fuel and compare both systems. The design of the water and gasoline engine pumping system were evaluated. The gasoline fuel cost used in rice cultivation in an area of 1.6 acres. Under same conditions of water pumping system is replaced by the photovoltaic system which is composed of a solar panel, a converter and an electric motor pump which is compose of a direct current (DC) motor or an alternating current (AC) motor with an inverter. In addition, the battery is installed to increase the efficiency and productivity of rice cultivation. In order to verify, the simulation and economic evaluation of the storage energy battery system with batteries and without batteries are carried out. Finally the cost of four solar pumping systems was evaluated and compared with that of the gasoline pump. The results showed that the solar pumping system can be used to replace the gasoline water pumping system and DC solar pump has a payback less than 10 years. The systems that can payback the fastest is the DC solar pumping system without batteries storage system. The system the can payback the slowest is AC solar pumping system with batteries storage system. However, VAC motor pump of 220 V can be more easily maintained than the motor pump of 24 VDC and batteries back up system can supply a more stable power to the pump system.

  2. 77 FR 13132 - Proposed Collection: Comment Request; Revision “PHS Applications and Pre-Award Reporting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-05

    ... individuals to indicate the start of their NRSA awards. The PHS 6031 Payback Agreement is used by individuals... activated and trainees appointed. Affected Public: Universities and other research institutions; Business or...

  3. Choosing a Geothermal as an HVAC System.

    ERIC Educational Resources Information Center

    Lensenbigler, John D.

    2002-01-01

    Describes the process of selecting and installing geothermal water source heat pumps for new residence halls at Johnson Bible College in Knoxville, Tennessee, including choosing the type of geothermal design, contractors, and interior equipment, and cost and payback. (EV)

  4. 78 FR 49532 - Request for Public Comment: 30-Day Proposed Information Collection: Application for Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... Scholarship recipients; monitor the academic performance of recipients; and to place recipients at payback... Initial Program Progress Report 1200 1 1200 0.13 ( 8 min) 160 (IHS-856-8). Notification of Academic...

  5. Public Housing: A Tailored Approach to Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Podorson, D.

    2014-06-01

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at themore » time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less

  6. Waste-to-methanol: Process and economics assessment.

    PubMed

    Iaquaniello, Gaetano; Centi, Gabriele; Salladini, Annarita; Palo, Emma; Perathoner, Siglinda; Spadaccini, Luca

    2017-11-01

    The waste-to-methanol (WtM) process and related economics are assessed to evidence that WtM is a valuable solution both from economic, strategic and environmental perspectives. Bio-methanol from Refuse-derived-fuels (RdF) has an estimated cost of production of about 110€/t for a new WtM 300t/d plant. With respect to waste-to-energy (WtE) approach, this solution allows various advantages. In considering the average market cost of methanol and the premium as biofuel, the WtM approach results in a ROI (Return of Investment) of about 29%, e.g. a payback time of about 4years. In a hybrid scheme of integration with an existing methanol plant from natural gas, the cost of production becomes a profit even without considering the cap for bio-methanol production. The WtM process allows to produce methanol with about 40% and 30-35% reduction in greenhouse gas emissions with respect to methanol production from fossil fuels and bio-resources, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Enabling VOLTTRON: Energy Management of Commercial Buildings at the University of Maryland

    NASA Astrophysics Data System (ADS)

    Ebhojiaye, Itohan Omisi

    Buildings waste approximately 30% of energy they consume due to inefficient HVAC and lighting operation. Building Automation Systems (BAS) can aid in reducing such wasted energy, but 90% of U.S. commercial buildings lack a BAS due to their high capital costs. This thesis demonstrates how VOLTTRON, an open source operating system developed by Pacific Northwest National Laboratory, was used to disable the mechanical cooling of a rooftop unit (RTU) during unoccupied hours, on a building without a BAS. With cooling off, the RTU's electricity dropped from 18 kW to 7kW. These results indicate 450 to 550 can be saved on the monthly electric bill of the building during the summer, compared to when the RTU operated in cooling mode continuously. The installation cost of the equipment that enabled the RTU to be controlled via VOLTTRON was $6,400, thus the project has a payback period of 13 months.

  8. Economic Evaluation of the Production Magnesium Oxide Nanoparticles via Liquid-Phase Route

    NASA Astrophysics Data System (ADS)

    Nandiyanto, A. B. D.; Fariansyah, R.; Ramadhan, M. F.; Abdullah, A. G.; Widiaty, I.

    2018-02-01

    The purpose of this study was to evaluate the production of magnesium oxide (MgO) nanoparticles. The evaluation was done in two perspectives: engineering and economic evaluation. The engineering perspective concerned about the analysis of the production rate based on the available apparatuses and raw materials, completed with mass balance calculation. The economic analysis was conducted based on several economic parameters: gross profit margin (GPM), internal return rate (IRR), payback period (PBP), cumulative net present value (CNPV), break even point (BEP), and profit to investment (PI). The engineering perspective showed that the production of MgO is feasibly done in small scale industry. This is verified by the potential production using current available apparatuses and raw materials in the market. Economic analysis obtained that the present project is profitable. But, for some cases, further studies must be done to get the present production process is attractive for investor.

  9. Cost-benefit analysis and emission reduction of energy efficient lighting at the Universiti Tenaga Nasional.

    PubMed

    Ganandran, G S B; Mahlia, T M I; Ong, Hwai Chyuan; Rismanchi, B; Chong, W T

    2014-01-01

    This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment.

  10. Carbon black dispersion pre-plating technology for printed wire board manufacturing. Final technology evaluation report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Folsom, D.W.; Gavaskar, A.R.; Jones, J.A.

    1993-10-01

    The project compared chemical use, waste generation, cost, and product quality between electroless copper and carbon-black-based preplating technologies at the printed wire board (PWB) manufacturing facility of McCurdy Circuits in Orange, CA. The carbon-black based preplating technology evaluated is used as an alternative process for electroless copper (EC) plating of through-holes before electrolytic copper plating. The specific process used at McCurdy is the BlackHole (BH) technology process, which uses a dispersion of carbon black in an aqueous solution to provide a conductive surface for subsequent electrolytic copper plating. The carbon-black dispersion technology provided effective waste reduction and long-term cost savings.more » The economic analysis determined that the new process was cost efficient because chemical use was reduced and the process proved more efficient; the payback period was less than 4 yrs.« less

  11. Dye Sensitized Solar Cells for Economically Viable Photovoltaic Systems.

    PubMed

    Jung, Hyun Suk; Lee, Jung-Kun

    2013-05-16

    TiO2 nanoparticle-based dye sensitized solar cells (DSSCs) have attracted a significant level of scientific and technological interest for their potential as economically viable photovoltaic devices. While DSSCs have multiple benefits such as material abundance, a short energy payback period, constant power output, and compatibility with flexible applications, there are still several challenges that hold back large scale commercialization. Critical factors determining the future of DSSCs involve energy conversion efficiency, long-term stability, and production cost. Continuous advancement of their long-term stability suggests that state-of-the-art DSSCs will operate for over 20 years without a significant decrease in performance. Nevertheless, key questions remain in regards to energy conversion efficiency improvements and material cost reduction. In this Perspective, the present state of the field and the ongoing efforts to address the requirements of DSSCs are summarized with views on the future of DSSCs.

  12. Steam bottoming cycle for an adiabatic diesel engine

    NASA Technical Reports Server (NTRS)

    Poulin, E.; Demier, R.; Krepchin, I.; Walker, D.

    1984-01-01

    Steam bottoming cycles using adiabatic diesel engine exhaust heat which projected substantial performance and economic benefits for long haul trucks were studied. Steam cycle and system component variables, system cost, size and performance were analyzed. An 811 K/6.90 MPa state of the art reciprocating expander steam system with a monotube boiler and radiator core condenser was selected for preliminary design. The costs of the diesel with bottoming system (TC/B) and a NASA specified turbocompound adiabatic diesel with aftercooling with the same total output were compared, the annual fuel savings less the added maintenance cost was determined to cover the increase initial cost of the TC/B system in a payback period of 2.3 years. Steam bottoming system freeze protection strategies were developed, technological advances required for improved system reliability are considered and the cost and performance of advanced systes are evaluated.

  13. Solarnorth '81 by Tymura Solardesigns: diverse residential, commercial and industrial projects at and above the 48th parallel in Ontario, Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tymura, E.J.

    1981-01-01

    Solar Energy Heating Applications are On the Rise in and above the Northwestern City of Thunder Bay, on the northern shore of Lake Superior. Unique in their diversifications, the architectural commissions range from pure passive residential design thru hybrid systems; residential Greenhouse-Solarium active swimming pool and commercial hotel pool to inexpensive hybrid system for Canada's First Commercial Solar Lumber Drying Kiln; as well as combined earth sheltered with solar system design for a dormitory complex and shopping center. By May 1981, 7 buildings designed by Tymura Solardesigns in the Thunder Bay area will have been subjected to the Extreme Canadianmore » climate (10,500/sup 0/F degree days, yearly temperature maximums from -41/sup 0/F to 90/sup 0/F, and solar fractions vary from 50% to 75%, with economic payback periods ranging between 7 and 10 years.« less

  14. Cost-Benefit Analysis and Emission Reduction of Energy Efficient Lighting at the Universiti Tenaga Nasional

    PubMed Central

    Ganandran, G. S. B.; Mahlia, T. M. I.; Ong, Hwai Chyuan; Rismanchi, B.; Chong, W. T.

    2014-01-01

    This paper reports the result of an investigation on the potential energy saving of the lighting systems at selected buildings of the Universiti Tenaga Nasional. The scope of this project includes evaluation of the lighting system in the Library, Admin Building, College of Engineering, College of Information Technology, Apartments, and COE Food court of the university. The main objectives of this project are to design the proper retrofit scenario and to calculate the potential electricity saving, the payback period, and the potential environmental benefits. In this survey the policy for retrofitting the old lighting system with the new energy saving LEDs starts with 10% for the first year and continues constantly for 10 years until all the lighting systems have been replaced. The result of the life cycle analysis reveals that after four years, the selected buildings will bring profit for the investment. PMID:25133258

  15. Life cycle assessment of biomethane use in Argentina.

    PubMed

    Morero, Betzabet; Groppelli, Eduardo; Campanella, Enrique A

    2015-04-01

    Renewable substitutes for natural gas, such as biogas, require adequate treatment to remove impurities. This paper presents the life cycle and environmental impact of upgrading biogas using absorption-desorption process with three different solvents: water, diglycolamine and polyethylene glycol dimethyl ether. The results showed that water produces a minor impact in most of the considered categories, and an economic analysis showed that water is the most feasible solvent for obtaining the lowest payback period. This analysis includes three different sources for biogas production and two end uses for biomethane. The use of different wastes as sources results in different environmental impacts depending on the type of energy used in the anaerobic digestion. The same situation occurs when considering the use of biomethane as a domestic fuel or for power generation. Using energy from biogas to replace conventional energy sources in production and upgrading biogas significantly reduce the environmental impacts of processes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Techno-economic evaluation of a combined bioprocess for fermentative hydrogen production from food waste.

    PubMed

    Han, Wei; Fang, Jun; Liu, Zhixiang; Tang, Junhong

    2016-02-01

    In this study, the techno-economic evaluation of a combined bioprocess based on solid state fermentation for fermentative hydrogen production from food waste was carried out. The hydrogen production plant was assumed to be built in Hangzhou and designed for converting 3 ton food waste per day into hydrogen. The total capital cost (TCC) and the annual production cost (APC) were US$583092 and US$88298.1/year, respectively. The overall revenue after the tax was US$146473.6/year. The return on investment (ROI), payback period (PBP) and internal rate of return (IRR) of the plant were 26.75%, 5 years and 24.07%, respectively. The results exhibited that the combined bioprocess for hydrogen production from food waste was feasible. This is an important study for attracting investment and industrialization interest for hydrogen production from food waste in the industrial scale. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Science and society test VI: Energy economics

    NASA Astrophysics Data System (ADS)

    Hafemeister, David W.

    1982-01-01

    Simple numerical estimates are developed in order to quantify a variety of energy economics issues. The Verhulst equation, which considers the effect of finite resources on petroleum production, is modified to take into account supply and demand economics. Numerical and analytical solutions to these differential equations are presented in terms of supply and demand elasticity functions, various finite resources, and the rate of increase in fuel costs. The indirect cost per barrel of imported oil from OPEC is shown to be about the same as the direct cost. These effects, as well as those of discounted benefits and deregulation, are used in a calculation of payback periods for various energy conserving devices. A phenomenological model for market penetration is developed along with the factors for future energy growth rates. A brief analysis of the economic returns of the ''house doctor'' program to reprofit houses for energy conservation is presented.

  18. Analysis of community income on suren (Toona sureni (Blume) Merr.) and cacao crops (Theobroma cacao L.) in Simalungun, North Sumatera-Indonesia

    NASA Astrophysics Data System (ADS)

    Latifah, S.; Afifuddin, Y.; Widya, S.

    2018-02-01

    Agroforestry is the management and integration of trees, crops and/or livestock on the same plot of land and can be an integral component of productive agriculture. It may include existing native forests and forests established by landholders. The study was conducted in Mekar Sari Raya village, Panei sub, Simalungun regency, North Sumatera. This study aims to gain the ability to use agroforestry in suren crops and cocoa that provides benefits to farmers and the feasibility of the model farm. The study site has Net Present Value (NPV) is 2,670,306,905 ( IDR) for 15 of year, Gross B/C Ratio (BCR) is 2.3; Internal Rate of Return ( IRR) is 28 %; and Payback Period (PP) for 5 years 4 months 24 days. Agroforestry using commodities cacao and suren crops are financially feasible to be cultivated and developed.

  19. Utilization of geothermal energy-feasibility study, Ojo Caliente Mineral Springs Company, Ojo Caliente, New Mexico

    NASA Astrophysics Data System (ADS)

    1982-04-01

    The feasibility of a geothermal heating system at the Ojo Caliente Mineral Springs Co. was investigated. The geothermal energy will be used to preheat hot water for the laundry facilities and to heat the water for a two pipe fan coil heating system in the hotel. Present annual heating fuel costs of $11,218 for propane will be replaced by electricity to operate fans and pump at an annual cost of $2547, resulting in a net savings of $8671. Installation costs include $10,100 for a well system, $1400 for a laundry system, and $41,100 for a heating system. With the addition of a 10% design fee the total installation cost is $57,860. Ignoring escalating propane fuel prices, tax credits for energy conservation equipment, and potential funding from the State of New Mexico for a geothermal demonstration project, the simple economic payback period for this project is 6.7 years.

  20. Economic feasibility of solar water and space heating.

    PubMed

    Bezdek, R H; Hirshberg, A S; Babcock, W H

    1979-03-23

    The economic feasibility in 1977 and 1978 of solar water and combined water and space heating is analyzed for single-family detached residences and multi-family apartment buildings in four representative U.S. cities: Boston, Massachusetts; Washington, D.C.; Grand Junction, Colorado; and Los Angeles, California. Three economic decision criteria are utilized: payback period, years to recovery of down payment, and years to net positive cash flow. The cost competitiveness of the solar systems compared to heating systems based on electricity, fuel oil, and natural gas is then discussed for each city, and the impact of the federal tax credit for solar energy systems is assessed. It is found that even without federal incentives some solar water and space heating systems are competitive. Enactment of the solar tax credit, however, greatly enhances their competitiveness. The implications of these findings for government tax and energy pricing policies are discussed.

  1. 34 CFR 263.8 - What are the payback requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... EDUCATION, DEPARTMENT OF EDUCATION INDIAN EDUCATION DISCRETIONARY GRANT PROGRAMS Professional Development... Professional Development program are required to— (1) Sign an agreement, at the time of selection for training... for which training was actually received under the Professional Development program. (c) The cash...

  2. Systematic review of methods for evaluating healthcare research economic impact

    PubMed Central

    2010-01-01

    Background The economic benefits of healthcare research require study so that appropriate resources can be allocated to this research, particularly in developing countries. As a first step, we performed a systematic review to identify the methods used to assess the economic impact of healthcare research, and the outcomes. Method An electronic search was conducted in relevant databases using a combination of specific keywords. In addition, 21 relevant Web sites were identified. Results The initial search yielded 8,416 articles. After studying titles, abstracts, and full texts, 18 articles were included in the analysis. Eleven other reports were found on Web sites. We found that the outcomes assessed as healthcare research payback included direct cost-savings, cost reductions in healthcare delivery systems, benefits from commercial advancement, and outcomes associated with improved health status. Two methods were used to study healthcare research payback: macro-economic studies, which examine the relationship between research studies and economic outcome at the aggregated level, and case studies, which examine specific research projects to assess economic impact. Conclusions Our study shows that different methods and outcomes can be used to assess the economic impacts of healthcare research. There is no unique methodological approach for the economic evaluation of such research. In our systematic search we found no research that had evaluated the economic return of research in low and middle income countries. We therefore recommend a consensus on practical guidelines at international level on the basis of more comprehensive methodologies (such as Canadian Academic of Health Science and payback frameworks) in order to build capacity, arrange for necessary informative infrastructures and promote necessary skills for economic evaluation studies. PMID:20196839

  3. A feasibility study of stationary and dual-axis tracking grid-connected photovoltaic systems in the Upper Midwest

    NASA Astrophysics Data System (ADS)

    Warren, Ryan Duwain

    Three primary objectives were defined for this work. The first objective was to determine, assess, and compare the performance, heat transfer characteristics, economics, and feasibility of real-world stationary and dual-axis tracking grid-connected photovoltaic (PV) systems in the Upper Midwest. This objective was achieved by installing two grid-connected PV systems with different mounting schemes in central Iowa, implementing extensive data acquisition systems, monitoring operation of the PV systems for one full year, and performing detailed experimental performance and economic studies. The two PV systems that were installed, monitored, and analyzed included a 4.59 kWp roof-mounted stationary system oriented for maximum annual energy production, and a 1.02 kWp pole-mounted actively controlled dual-axis tracking system. The second objective was to demonstrate the actual use and performance of real-world stationary and dual-axis tracking grid-connected PV systems used for building energy generation applications. This objective was achieved by offering the installed PV systems to the public for demonstration purposes and through the development of three computer-based tools: a software interface that has the ability to display real-time and historical performance and meteorological data of both systems side-by-side, a software interface that shows real-time and historical video and photographs of each system, and a calculator that can predict performance and economics of stationary and dual-axis tracking grid-connected PV systems at various locations in the United States. The final objective was to disseminate this work to social, professional, scientific, and academic communities in a way that is applicable, objective, accurate, accessible, and comprehensible. This final objective will be addressed by publishing the results of this work and making the computer-based tools available on a public website (www.energy.iastate.edu/Renewable/solar). Detailed experimental performance analyses were performed for both systems; results were quantified and compared between systems, focusing on measures of solar resource, energy generation, power production, and efficiency. This work also presents heat transfer characteristics of both arrays and quantifies the affects of operating temperature on PV system performance in terms of overall heat transfer coefficients and temperature coefficients for power. To assess potential performance of PV in the Upper Midwest, models were built to predict performance of the PV systems operating at lower temperatures. Economic analyses were performed for both systems focusing on measures of life-cycle cost, payback period, internal rate of return, and average incremental cost of solar energy. The potential economic feasibility of grid-connected stationary PV systems used for building energy generation in the Upper Midwest was assessed under assumptions of higher utility energy costs, lower initial installed costs, and different metering agreements. The annual average daily solar insolation seen by the stationary and dual-axis tracking systems was found to be 4.37 and 5.95 kWh/m2, respectively. In terms of energy generation, the tracking system outperformed the stationary system on annual, monthly, and often daily bases; normalized annual energy generation for the tracking and stationary systems were found to be 1,779 and 1,264 kWh/kWp, respectively. The annual average conversion efficiencies of the tracking and stationary systems were found to be approximately 11 and 10.7 percent, respectively. Annual performance ratio values of the tracking and stationary system were found to be 0.819 and 0.792, respectively. The net present values of both systems under all assumed discount rates were determined to be negative. Further, neither system was found to have a payback period less than the assumed system life of 25 years. The rate-of-return of the stationary and tracking systems were found to be -3.3 and -4.9 percent, respectively. Furthermore, the average incremental cost of energy provided by the stationary and dual-axis tracking systems over their assumed useful life is projected to be 0.31 and 0.37 dollars per kWh, respectively. Results of this study suggest that grid-connected PV systems used for building energy generation in the Upper Midwest are not yet economically feasible when compared to a range of alternative investments; however, PV systems could show feasibility under more favorable economic scenarios. Throughout the year of monitoring, array operating temperatures ranged from -24.7°C (-12.4°F) to 61.7°C (143.1°F) for the stationary system and -23.9 °C (-11°F) to 52.7°C (126.9°F) for the dual-axis tracking system during periods of system operation. The hourly average overall heat transfer coefficients for solar irradiance levels greater than 200 W/m 2 for the stationary and dual-axis tracking systems were found to be 20.8 and 29.4 W/m2°C, respectively. The experimental temperature coefficients for power for the stationary and dual-axis tracking systems at a solar irradiance level of 1,000 W/m2 were -0.30 and -0.38 %/°C, respectively. Simulations of the stationary and dual-axis tracking systems operating at lower temperatures suggest that annual conversion efficiencies could potentially be increased by to up 4.3 and 4.6 percent, respectively.

  4. Reduction of enteric infectious disease in rural China by providing deep-well tap water.

    PubMed Central

    Wang, Z. S.; Shepard, D. S.; Zhu, Y. C.; Cash, R. A.; Zhao, R. J.; Zhu, Z. X.; Shen, F. M.

    1989-01-01

    Enteric infectious disease (EID), defined here as bacillary dysentery, viral hepatitis A, El Tor cholera, or acute watery diarrhoea, is an important public health problem in most developing countries. This study assessed the impact on EID of providing deep-well tap water (DWTW) through household taps in rural China. For this purpose, we compared the incidence of EID in six study villages (population, 10,290) in Qidong County that had DWTW with that in six control villages (population 9397) that had only surface water. Both the bacterial counts and chemical properties of the DWTW met established hygiene standards for drinking water. The incidence of EID in the study region was 38.6% lower than in the control region; however, the introduction of DWTW supplies did not significantly affect the incidence of bacillary dysentery. These results indicate that the construction and use of DWTW systems with household taps is associated with decreased incidences of El Tor cholera, viral hepatitis A, and acute watery diarrhoea. Since high construction costs have led many authorities to question the value of DWTW, we carried out a cost-benefit analysis of the programme. The cost of constructing a DWTW system averaged US $36,000 at 1983 prices, or US $10.50 per capita. The combined capital and operating costs of a DWTW system were US $1.46 per capita per annum over its 20-year estimated life. The benefits derived from reductions in cost of illness and savings in time to fetch water were 2.2 times the costs at present values Capital outlays were recouped in a 3.6-year payback period and the provision of DWTW proved highly beneficial in both economic and social terms. PMID:2501042

  5. Bedside ROP screening and telemedicine interpretation integrated to a neonatal transport system: Economic aspects and return on investment analysis.

    PubMed

    Kovács, Gábor; Somogyvári, Zsolt; Maka, Erika; Nagyjánosi, László

    Peter Cerny Ambulance Service - Premature Eye Rescue Program (PCA-PERP) uses digital retinal imaging (DRI) with remote interpretation in bedside ROP screening, which has advantages over binocular indirect ophthalmoscopy (BIO) in screening of premature newborns. We aimed to demonstrate that PCA-PERP provides good value for the money and to model the cost ramifications of a similar newly launched system. As DRI was demonstrated to have high diagnostic performance, only the costs of bedside DRI-based screening were compared to those of traditional transport and BIO-based screening (cost-minimization analysis). The total costs of investment and maintenance were analyzed with micro-costing method. A ten-year analysis time-horizon and service provider's perspective were applied. From the launch of PCA-PERP up to the end of 2014, 3722 bedside examinations were performed in the PCA covered central region of Hungary. From 2009 to 2014, PCA-PERP saved 92,248km and 3633 staff working hours, with an annual nominal cost-savings ranging from 17,435 to 35,140 Euro. The net present value was 127,847 Euro at the end of 2014, with a payback period of 4.1years and an internal rate of return of 20.8%. Our model presented the NPVs of different scenarios with different initial investments, annual number of transports and average transport distances. PCA-PERP as bedside screening with remote interpretation, when compared to a transport-based screening with BIO, produced better cost-savings from the perspective of the service provider and provided a return on initial investment within five years after the project initiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. MOD control center automated information systems security evolution

    NASA Technical Reports Server (NTRS)

    Owen, Rich

    1991-01-01

    The role of the technology infusion process in future Control Center Automated Information Systems (AIS) is highlighted. The following subject areas are presented in the form of the viewgraphs: goals, background, threat, MOD's AISS program, TQM, SDLC integration, payback, future challenges, and bottom line.

  7. Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-11-01

    This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryersmore » used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  8. Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-12-01

    The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers usedmore » for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  9. Cost effective solar hot water system for Econo-Travel Motor Hotel located at Woodbrdge, VA. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1978-11-01

    The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 13317 Gordon Boulevard, Woodbridge, Virginia is given. The description of the system along with the final breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 7.2 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used formore » the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.« less

  10. Industry's tireless eyes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-08-01

    This article reports that there are literally hundreds of machine vision systems from which to choose. They range in cost from $10,000 to $1,000,000. Most have been designed for specific applications; the same systems if used for a different application may fail dismally. How can you avoid wasting money on inferior, useless, or nonexpandable systems. A good reference is the Automated Vision Association in Ann Arbor, Mich., a trade group comprised of North American machine vision manufacturers. Reputable suppliers caution users to do their homework before making an investment. Important considerations include comprehensive details on the objects to be viewed-thatmore » is, quantity, shape, dimension, size, and configuration details; lighting characteristics and variations; component orientation details. Then, what do you expect the system to do-inspect, locate components, aid in robotic vision. Other criteria include system speed and related accuracy and reliability. What are the projected benefits and system paybacks.. Examine primarily paybacks associated with scrap and rework reduction as well as reduced warranty costs.« less

  11. DEEP: A Database of Energy Efficiency Performance to Accelerate Energy Retrofitting of Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoon Lee, Sang; Hong, Tianzhen; Sawaya, Geof

    The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions andmore » 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit. DEEP will be migrated into the DEnCity - DOE’s Energy City, which integrates large-scale energy data for multi-purpose, open, and dynamic database leveraging diverse source of existing simulation data.« less

  12. Action Research: Enhancing Classroom Practice and Fulfilling Educational Responsibilities

    ERIC Educational Resources Information Center

    Young, Mark R.; Rapp, Eve; Murphy, James W.

    2010-01-01

    Action Research is an applied scholarly paradigm resulting in action for continuous improvement in our teaching and learning techniques offering faculty immediate classroom payback and providing documentation of meeting our educational responsibilities as required by AACSB standards. This article reviews the iterative action research process of…

  13. The financial viability of an SOFC cogeneration system in single-family dwellings

    NASA Astrophysics Data System (ADS)

    Alanne, Kari; Saari, Arto; Ugursal, V. Ismet; Good, Joel

    In the near future, fuel cell-based residential micro-CHP systems will compete with traditional methods of energy supply. A micro-CHP system may be considered viable if its incremental capital cost compared to its competitors equals to cumulated savings during a given period of time. A simplified model is developed in this study to estimate the operation of a residential solid oxide fuel cell (SOFC) system. A comparative assessment of the SOFC system vis-à-vis heating systems based on gas, oil and electricity is conducted using the simplified model for a single-family house located in Ottawa and Vancouver. The energy consumption of the house is estimated using the HOT2000 building simulation program. A financial analysis is carried out to evaluate the sensitivity of the maximum allowable capital cost with respect to system sizing, acceptable payback period, energy price and the electricity buyback strategy of an energy utility. Based on the financial analysis, small (1-2 kW e) SOFC systems seem to be feasible in the considered case. The present study shows also that an SOFC system is especially an alternative to heating systems based on oil and electrical furnaces.

  14. CO2 heat pumps for commercial building applications with simultaneous heating and cooling demand

    NASA Astrophysics Data System (ADS)

    Dharkar, Supriya

    Many commercial buildings, including data centers, hotels and hospitals, have a simultaneous heating and cooling demand depending on the season, occupation and auxiliary equipment. A data center on the Purdue University, West Lafayette campus is used as a case study. The electrical equipment in data centers produce heat, which must be removed to prevent the equipment temperature from rising to a certain level. With proper integration, this heat has the potential to be used as a cost-effective energy source for heating the building in which the data center resides or the near-by buildings. The proposed heat pump system utilizes carbon dioxide with global warming potential of 1, as the refrigerant. System simulations are carried out to determine the feasibility of the system for a 12-month period. In addition, energy, environmental and economic analyses are carried out to show the benefits of this alternative technology when compared to the conventional system currently installed in the facility. Primary energy savings of ~28% to ~61%, a payback period of 3 to 4.5 years and a decrease in the environmental impact value by ~36% makes this system an attractive option. The results are then extended to other commercial buildings.

  15. The effects of regeneration temperature of the desiccant wheel on the performance of desiccant cooling cycles for greenhouse thermally insulated

    NASA Astrophysics Data System (ADS)

    Rjibi, Amel; Kooli, Sami; Guizani, Amenaallah

    2018-05-01

    The use of solar energy for cooling greenhouses in the hot period in Mediterranean climate is an important issue. Desiccant evaporative cooling (DEC) system is advantageous because it uses a low grade thermal energy and preserves the merits to be friendly environmentally technology. In this paper, a numerical investigation was carried out on a desiccant cooling system powered by air solar collectors coupled to an insulated greenhouse. The influence of the regeneration temperature on the air stream properties at every system component state point was studied. The performance of the desiccant cooling system was evaluated in terms of thermal and electric coefficient of performance. Results show that the best performance of the system (COPel = 14 and COPth = 0.94) was obtained for a 60 °C regeneration temperature and a supply flow rate ratio of 0.2. An economic analysis shows that the use of the DEC system for greenhouse cooling is attractive and profitable since the payback period is 1 years. The use of the proposed system allows saving 9396 kWh/year of electric energy compared to conventional system.

  16. Building America Case Study: Philadelphia Housing Authority Energy-Efficiency Turnover Protocols, Philadelphia, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-02-01

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16 percent and duct leakage reductions averaged 23 percent. Total source energy consumption savings due to implemented measures was estimated at 3-10 percent based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less

  17. Islip Housing Authority Energy Efficiency Turnover Protocols, Islip, New York (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-08-01

    More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations atmore » the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.« less

  18. Public Housing: A Tailored Approach to Energy Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Podorson, D.

    2016-02-18

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time whenmore » units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16% and duct leakage reductions averaged 23%. Total source energy consumption savings due to implemented measures was estimated at 3-10% based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.« less

  19. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  20. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  1. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  2. 20 CFR 655.310 - Attestations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... school, and the course of study shall be one accredited by a State Board of Nursing (or its equivalent... 4-year college, or a diploma school. See § 655.350(b) of this part. Financing by the facility... or pay-back programs) to such persons. (ii) Unreasonableness of second step. The steps described in...

  3. 20 CFR 655.310 - Attestations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... school, and the course of study shall be one accredited by a State Board of Nursing (or its equivalent... 4-year college, or a diploma school. See § 655.350(b) of this part. Financing by the facility... or pay-back programs) to such persons. (ii) Unreasonableness of second step. The steps described in...

  4. 20 CFR 655.1114 - Element IV-What are the timely and significant steps an H-1C employer must take to recruit and...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... diploma school, and the course of study must be one accredited by a State Board of Nursing (or its... by means of financial assistance (e.g., scholarship, loan or pay-back programs) to such persons. (v...

  5. 7 CFR 4288.21 - Application review and scoring.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...

  6. 7 CFR 4288.21 - Application review and scoring.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...

  7. 7 CFR 4288.21 - Application review and scoring.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... projects based on the cost, cost-effectiveness, and capacity of projects to reduce fossil fuels. The cost... economically produce energy from renewable biomass to replace its dependence on fossil fuels. Projects with... projects on simple payback as well as the percentage of fossil fuel reduction. (a) Review. The Agency will...

  8. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... building energy or water system with an energy or water conservation measure by retrofit to an existing... estimated payback time is significantly less than the useful life of that system, and of the Federal...

  9. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... building energy or water system with an energy or water conservation measure by retrofit to an existing... estimated payback time is significantly less than the useful life of that system, and of the Federal...

  10. Fast Payback

    ERIC Educational Resources Information Center

    Simon, David

    2008-01-01

    Energy costs are projected to rise as much as 12 percent in 2008, and a facility's "carbon footprint" has become an issue of increasing importance. So, many schools and universities are taking a hard look at their energy consumption. Education facilities can save tens of thousands of dollars in yearly electric costs, and cut harmful emissions by…

  11. SOLFEAS: An Interactive Program for Estimating the Economic Feasibility of an Active Solar Thermal Energy System.

    DTIC Science & Technology

    1983-01-01

    SOt MET State city Station Number HAWAII Barbers Point 22514 Hilo 21504 Honolulu 22521 Lihue 22536 IDAHO Boise 24131 Lewiston 24149 Pocatello 24156...Hawaii 10 Washington, Oregon, Idaho , Alaska SOLFEAS treats the impact of these published fuel costs and escalation rates on the system payback as

  12. Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting at T.J.Maxx in Manchester, NH Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myer, Michael; Goettel, Russell T.

    2010-06-29

    A report describing the process and results of replacing existing parking lot lighting, looking at a LED option with occupancy sensors, and conventional alternates. Criteria include payback, light levels, occupant satisfaction. This report is Phase I of II. Phase I deals with initial installation.

  13. Payback Time? Discourses of Lack, Debt and the Moral Regulation of Teacher Education

    ERIC Educational Resources Information Center

    Beighton, Chris

    2016-01-01

    This paper analyses recent policy and discourse in the UK lifelong learning sector to identify a tension in discourse which positions teacher educators as essential to the knowledge economy while simultaneously insisting on the deficits they represent. Drawing on critical analyses from Friedrich Nietzsche, Maurizio Lazzarato and Gilles Deleuze, I…

  14. 78 FR 76759 - Magnuson-Stevens Fishery Conservation and Management Act Provisions; Fisheries of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... determination. This rule implements a system of AMs that would result in a payback if: (1) The stock is... catch target (ACT) setting process because it is ``flawed and produces highly inaccurate results,'' but... chronic overharvesting in the recreational fishery. NMFS does not have the legal authority to redistribute...

  15. Energy Assessment Helps Kaiser Aluminum Save Energy and Improve Productivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2008-07-01

    The Kaiser Aluminum plant in Sherman, Texas, adjusted controls and made repairs to a furnace for a simple payback of 1 month. Kaiser adopted DOE's Process Heating Assessment and Survey Tool (PHAST) software as the corporate diagnostic tool and has used it to evaluate process heating systems at five other aluminum plants.

  16. 78 FR 36197 - Request for Public Comment: 60-Day Proposed Information Collection: Application for Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-17

    ... Section 3506 (c)(2)(A) of the Paperwork Reduction Act of 1995 which requires 60-days advance opportunity... Management and Budget (OMB) for review. Proposed Collection: Title: 0917-0006, ``Application for... performance of recipients; and to place recipients at payback sites. The IHS Scholarship Program streamlined...

  17. A Comparison of Prediction Methods for Design of Pump as Turbine for Small Hydro Plant: Implemented Plant

    NASA Astrophysics Data System (ADS)

    Naeimi, Hossein; Nayebi Shahabi, Mina; Mohammadi, Sohrab

    2017-08-01

    In developing countries, small and micro hydropower plants are very effective source for electricity generation with energy pay-back time (EPBT) less than other conventional electricity generation systems. Using pump as turbine (PAT) is an attractive, significant and cost-effective alternative. Pump manufacturers do not normally provide the characteristic curves of their pumps working as turbines. Therefore, choosing an appropriate Pump to work as a turbine is essential in implementing the small-hydro plants. In this paper, in order to find the best fitting method to choose a PAT, the results of a small-hydro plant implemented on the by-pass of a Pressure Reducing Valve (PRV) in Urmia city in Iran are presented. Some of the prediction methods of Best Efficiency Point of PATs are derived. Then, the results of implemented project have been compared to the prediction methods results and the deviation of from measured data were considered and discussed and the best method that predicts the specifications of PAT more accurately determined. Finally, the energy pay-back time for the plant is calculated.

  18. Payback time for soil carbon and sugar-cane ethanol

    NASA Astrophysics Data System (ADS)

    Mello, Francisco F. C.; Cerri, Carlos E. P.; Davies, Christian A.; Holbrook, N. Michele; Paustian, Keith; Maia, Stoécio M. F.; Galdos, Marcelo V.; Bernoux, Martial; Cerri, Carlos C.

    2014-07-01

    The effects of land-use change (LUC) on soil carbon (C) balance has to be taken into account in calculating the CO2 savings attributed to bioenergy crops. There have been few direct field measurements that quantify the effects of LUC on soil C for the most common land-use transitions into sugar cane in Brazil, the world's largest producer . We quantified the C balance for LUC as a net loss (carbon debt) or net gain (carbon credit) in soil C for sugar-cane expansion in Brazil. We sampled 135 field sites to 1 m depth, representing three major LUC scenarios. Our results demonstrate that soil C stocks decrease following LUC from native vegetation and pastures, and increase where cropland is converted to sugar cane. The payback time for the soil C debt was eight years for native vegetation and two to three years for pastures. With an increasing need for biofuels and the potential for Brazil to help meet global demand, our results will be invaluable for guiding expansion policies of sugar-cane production towards greater sustainability.

  19. Is a Clean Development Mechanism project economically justified? Case study of an International Carbon Sequestration Project in Iran.

    PubMed

    Katircioglu, Salih; Dalir, Sara; Olya, Hossein G

    2016-01-01

    The present study evaluates a carbon sequestration project for the three plant species in arid and semiarid regions of Iran. Results show that Haloxylon performed appropriately in the carbon sequestration process during the 6 years of the International Carbon Sequestration Project (ICSP). In addition to a high degree of carbon dioxide sequestration, Haloxylon shows high compatibility with severe environmental conditions and low maintenance costs. Financial and economic analysis demonstrated that the ICSP was justified from an economic perspective. The financial assessment showed that net present value (NPV) (US$1,098,022.70), internal rate of return (IRR) (21.53%), and payback period (6 years) were in an acceptable range. The results of the economic analysis suggested an NPV of US$4,407,805.15 and an IRR of 50.63%. Therefore, results of this study suggest that there are sufficient incentives for investors to participate in such kind of Clean Development Mechanism (CDM) projects.

  20. Biohydrogen production from waste bread in a continuous stirred tank reactor: A techno-economic analysis.

    PubMed

    Han, Wei; Hu, Yun Yi; Li, Shi Yi; Li, Fei Fei; Tang, Jun Hong

    2016-12-01

    Biohydrogen production from waste bread in a continuous stirred tank reactor (CSTR) was techno-economically assessed. The treating capacity of the H 2 -producing plant was assumed to be 2 ton waste bread per day with lifetime of 10years. Aspen Plus was used to simulate the mass and energy balance of the plant. The total capital investment (TCI), total annual production cost (TAPC) and annual revenue of the plant were USD931020, USD299746/year and USD639920/year, respectively. The unit hydrogen production cost was USD1.34/m 3 H 2 (or USD14.89/kg H 2 ). The payback period and net present value (NPV) of the plant were 4.8years and USD1266654, respectively. Hydrogen price and operators cost were the most important variables on the NPV. It was concluded that biohydrogen production from waste bread in the CSTR was feasible for practical application. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Demonstration Assessment of Light-Emitting Diode Parking Structure Lighting at U.S. Department of Labor Headquarters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    2013-03-01

    This report documents a solid-state lighting (SSL) technology demonstration at the parking structure of the U.S. Department of Labor (DOL) Headquarters in Washington, DC, in which light-emitting diode (LED) luminaires were substituted for the incumbent high-pressure sodium (HPS) luminaires and evaluated for relative light quantity and performance. The demonstration results show energy savings of 52% from the initial conversion of HPS to the LED product. These savings were increased to 88% by using occupancy sensor controls that were ultimately set to reduce power to 10% of high state operation after a time delay of 2.5 minutes. Because of the relativelymore » high cost of the LED luminaires at their time of purchase for this project (2010), the simple payback periods were 6.5 years and 4.9 years for retrofit and new construction scenarios, respectively. Staff at DOL Headquarters reported high satisfaction with the operation of the LED product.« less

  2. Energy efficiency opportunities in the brewery industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Worrell, Ernst; Galitsky, Christina; Martin, Nathan

    2002-06-28

    Breweries in the United States spend annually over $200 Million on energy. Energy consumption is equal to 3-8% of the production costs of beer, making energy efficiency improvement an important way to reduce costs, especially in times of high energy price volatility. After a summary of the beer making process and energy use, we examine energy efficiency opportunities available for breweries. We provide specific primary energy savings for each energy efficiency measure based on case studies that have implemented the measures, as well as references to technical literature. If available, we have also listed typical payback periods. Our findings suggestmore » that there may still be opportunities to reduce energy consumption cost-effectively for breweries. Major brewing companies have and will continue to spend capital on cost effective measures that do not impact the quality of the beer. Further research on the economics of the measures, as well as their applicability to different brewing practices, is needed to assess implementation of selected technologies at individual breweries.« less

  3. High Voltage Distribution System (HVDS) as a better system compared to Low Voltage Distribution System (LVDS) applied at Medan city power network

    NASA Astrophysics Data System (ADS)

    Dinzi, R.; Hamonangan, TS; Fahmi, F.

    2018-02-01

    In the current distribution system, a large-capacity distribution transformer supplies loads to remote locations. The use of 220/380 V network is nowadays less common compared to 20 kV network. This results in losses due to the non-optimal distribution transformer, which neglected the load location, poor consumer profile, and large power losses along the carrier. This paper discusses how high voltage distribution systems (HVDS) can be a better system used in distribution networks than the currently used distribution system (Low Voltage Distribution System, LVDS). The proposed change of the system into the new configuration is done by replacing a large-capacity distribution transformer with some smaller-capacity distribution transformers and installed them in positions that closest to the load. The use of high voltage distribution systems will result in better voltage profiles and fewer power losses. From the non-technical side, the annual savings and payback periods on high voltage distribution systems will also be the advantage.

  4. Technical and economic feasibility of a solar-bio-powered waste utilization and treatment system in Central America.

    PubMed

    Aguilar Alvarez, Ronald Esteban; Bustamante Roman, Mauricio; Kirk, Dana; Miranda Chavarria, Jose Alberto; Baudrit, Daniel; Aguilar Pereira, Jose Francisco; Rodriguez Montero, Werner; Reinhold, Dawn; Liao, Wei

    2016-12-15

    The purpose of this study was to implement and evaluate a pilot-scale and closed-loop system that synergistically combines solar thermal collector, anaerobic digester, and constructed treatment wetland to simultaneously treat and utilize organic wastes. The system utilizes 863 kg of mixed animal and food wastes to generate 263 MJ renewable energy, produced 28 kg nitrogen and phosphorus fertilizer, and reclaimed 550 kg water per day. The net revenue considering electricity and fertilizer was $2436 annually. The payback period for the system is estimated to be 17.8 years for a relatively dilute waste stream (i.e., 2% total solids). The implemented system has successfully demonstrated a self-efficient and flexible waste utilization and treatment system. It creates a win-win solution to satisfy the energy needs of the community and address environmental concerns of organic wastes disposal in the region. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Retrofit energy conservation in residential buildings in southern California

    NASA Technical Reports Server (NTRS)

    Turner, R. H.; Birur, G. C.; Daksla, C.

    1982-01-01

    The common energy conservation techniques (ECTs) that can be retrofit-installed into residential buildings are surveyed. The quantity of saved energy for heating and cooling attributable to each ECT is evaluated for three common modes of heating: natural gas heating at 60/therm; heating via heat pump at $1.20/therm; and electric resistance heating at $2.40/therm. In every case, a life cycle cost comparison is made between the long term revenue due to energy conservation and a safe and conventional alternative investment that might be available to the prudent homeowner. The comparison between investment in an ECT and the alternative investment is brought into perspective using the life cycle payback period and an economic Figure of Merit (FOM). The FOM allows for relative ranking between candidate ECTs. Because the entire spectrum of winter heating climates in California is surveyed, the decision maker can determine whether or not a considered ECT is recommended in a given climate, and under what conditions an ECT investment becomes attractive.

  6. End-of-life healthcare expenditure: Testing economic explanations using a discrete choice experiment.

    PubMed

    Fischer, Barbara; Telser, Harry; Zweifel, Peter

    2018-06-07

    Healthcare expenditure (HCE) spent during an individual's last year of life accounts for a high share of lifetime HCE. This finding is puzzling because an investment in health is unlikely to have a sufficiently long payback period. However, Becker et al. (2007) and Philipson et al. (2010) have advanced a theory designed to explain high willingness to pay (WTP) for an extension of life close to its end. Their testable implications are complemented by the concept of 'pain of risk bearing' introduced by Eeckhoudt and Schlesinger (2006). They are tested using a discrete choice experiment performed in 2014, involving 1,529 Swiss adults. An individual setting where the price attribute is substantial out-of-pocket payment for a novel drug for treatment of terminal cancer is distinguished from a societal one, where it is an increase in contributions to social health insurance. Most of the economic predictions receive empirical support. Copyright © 2018. Published by Elsevier B.V.

  7. Cost effective dry anaerobic digestion in textile bioreactors: Experimental and economic evaluation.

    PubMed

    Patinvoh, Regina J; Osadolor, Osagie A; Sárvári Horváth, Ilona; Taherzadeh, Mohammad J

    2017-12-01

    The aim of this work was to study dry anaerobic digestion (dry-AD) of manure bedded with straw using textile-based bioreactor in repeated batches. The 90-L reactor filled with the feedstocks (22-30% total solid) and inoculum without any further treatment, while the biogas produced were collected and analyzed. The digestate residue was also analyzed to check its suitability as bio-fertilizer. Methane yield after acclimatization increased from 183 to 290NmlCH 4 /gVS, degradation time decreased from 136 to 92days and the digestate composition point to suitable bio-fertilizer. The results then used to carry out economical evaluation, which shows dry-AD in textile bioreactors is a profitable method of handling the waste with maximum payback period of 5years, net present value from $7,000 to $9,800,000 (small to large bioreactors) with internal rate of return from 56.6 to 19.3%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Potential for large-scale solar collector system to offset carbon-based heating in the Ontario greenhouse sector

    NASA Astrophysics Data System (ADS)

    Semple, Lucas M.; Carriveau, Rupp; Ting, David S.-K.

    2018-04-01

    In the Ontario greenhouse sector the misalignment of available solar radiation during the summer months and large heating demand during the winter months makes solar thermal collector systems an unviable option without some form of seasonal energy storage. Information obtained from Ontario greenhouse operators has shown that over 20% of annual natural gas usage occurs during the summer months for greenhouse pre-heating prior to sunrise. A transient model of the greenhouse microclimate and indoor conditioning systems is carried out using TRNSYS software and validated with actual natural gas usage data. A large-scale solar thermal collector system is then incorporated and found to reduce the annual heating energy demand by approximately 35%. The inclusion of the collector system correlates to a reduction of about 120 tonnes of CO2 equivalent emissions per acre of greenhouse per year. System payback period is discussed considering the benefits of a future Ontario carbon tax.

  9. Wood-fired fuel cells in selected buildings

    NASA Astrophysics Data System (ADS)

    McIlveen-Wright, D. R.; McMullan, J. T.; Guiney, D. J.

    The positive attributes of fuel cells for high efficiency power generation at any scale and of biomass as a renewable energy source which is not intermittent, location-dependent or very difficult to store, suggest that a combined heat and power (CHP) system consisting of a fuel cell integrated with a wood gasifier (FCIWG) may offer a combination for delivering heat and electricity cleanly and efficiently. Phosphoric acid fuel cell (PAFC) systems, fuelled by natural gas, have already been used in a range of CHP applications in urban settings. Some of these applications are examined here using integrated biomass gasification/fuel cell systems in CHP configurations. Five building systems, which have different energy demand profiles, are assessed. These are a hospital, a hotel, a leisure centre, a multi-residential community and a university hall of residence. Heat and electricity use profiles for typical examples of these buildings were obtained and the FCIWG system was scaled to the power demand. The FCIWG system was modelled for two different types of fuel cell, the molten carbonate and the phosphoric acid. In each case an oxygen-fired gasification system is proposed, in order to eliminate the need for a methane reformer. Technical, environmental and economic analyses of each version were made, using the ECLIPSE process simulation package. Since fuel cell lifetimes are not yet precisely known, economics for a range of fuel cell lifetimes have been produced. The wood-fired PAFC system was found to have low electrical efficiency (13-16%), but much of the heat could be recovered, so that the overall efficiency was 64-67%, suitable where high heat/electricity values are required. The wood-fired molten carbonate fuel cell (MCFC) system was found to be quite efficient for electricity generation (24-27%), with an overall energy efficiency of 60-63%. The expected capital costs of both systems would currently make them uncompetitive for general use, but the specific features of selected buildings in rural areas, with regard to the high cost of importing other fuel, and/or lack of grid electricity, could still make these systems attractive options. Any economic analysis of these systems is beset with severe difficulties. Capital costs of the major system components are not known with any great precision. However, a guideline assessment of the payback period for such CHP systems was made. When the best available capital costs for system components were used, most of these systems were found to have unacceptably long payback periods, particularly where the fuel cell lifetimes are short, but the larger systems show the potential for a reasonable economic return.

  10. Alternative Fuels Data Center: Massachusetts Fleet Braun's Express

    Science.gov Websites

    economy by an estimated 1 mile per gallon (MPG) across Braun's 185 tractor fleet. This equates to 1,500 has collected, the APUs improve overall fuel economy from 5.87 MPG to 6.75 MPG and have a payback Aerodynamics Technologies that improve a vehicle's aerodynamics can provide significant fuel economy

  11. Solar power satellite. Concept evaluation. Activities report. Volume 2: Detailed report

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Comparative data are presented among various design approaches to thermal engine and photovoltaic SPS (Solar Power System) concepts, to provide criteria for selecting the most promising systems for more detailed definition. The major areas of the SPS system to be examined include solar cells, microwave power transmission, transportation, structure, rectenna, energy payback, resources, and environmental issues.

  12. Save Energy Now Assessment Helps Expand Energy Management Program at Shaw Industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The Shaw Industries carpet manufacturing plant #20 in Dalton, Georgia, optimized boiler operation and installed waste heat exchangers on two processes in the dye house and an economizer on one boiler, for a payback of 1.7 years. These results prompted plant #4, also located in Dalton, to participate in an assessment.

  13. Choice Behavior of Nonpathological Women Playing Concurrently Available Slot Machines: Effect of Changes in Payback Percentages

    ERIC Educational Resources Information Center

    Weatherly, Jeffrey N.; Thompson, Bradley J.; Hodny, Marisa; Meier, Ellen

    2009-01-01

    In a simulated casino environment, 6 nonpathological women played concurrently available commercial slot machines programmed to pay out at different rates. Participants did not always demonstrate preferences for the higher paying machine. The data suggest that factors other than programmed or obtained rate of reinforcement may control gambling…

  14. Lessons Learned from the Private Sector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robichaud, Robert J

    This session is focused on lessons learned from private sector energy projects that could be applied to the federal sector. This presentation tees up the subsequent presentations by outlining the differences between private and federal sectors in objectives, metrics for determining success, funding resources/mechanisms, payback and ROI evaluation, risk tolerance/aversion, new technology adoption perspectives, and contracting mechanisms.

  15. 75 FR 20369 - Request for Public Comment: 30-Day Proposed Information Collection: Application for Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-19

    ... Act of 1995 which requires a 30-day advance opportunity for public comment on the proposed information collection project, the Indian Health Service (IHS) has submitted to the Office of Management and Budget (OMB... the academic performance of awardees, to place awardees at payback sites, and for awardees to request...

  16. Addressing Student Debt: A New Post Secondary Learning Support System

    ERIC Educational Resources Information Center

    Association of Canadian Community Colleges, 2001

    2001-01-01

    Access and affordability are bountiful concepts and key words used by policy makers in defining the role of post-secondary education and training in Canada. However, these words have not translated into action for many learners due to student debt. Incurred from high tuition fees, costly and complex payback schemes and under-funding, chronic…

  17. Comparison of fermented animal feed and mushroom growth media as two value-added options for waste Cassava pulp management.

    PubMed

    Trakulvichean, Sivalee; Chaiprasert, Pawinee; Otmakhova, Julia; Songkasiri, Warinthorn

    2017-12-01

    Cassava is one of the main processed crops in Thailand, but this generates large amounts (7.3 million tons in 2015) of waste cassava pulp (WCP). The solid WCP is sold directly to farmers or pulp-drying companies at a low cost to reduce the burden of on-site waste storage. Using an integrated direct and environmental cost model, fermented animal feed and mushroom growth media were compared as added-value waste management alternatives for WCP to mitigate environmental problems. Primary and secondary data were collected from the literature, field data, and case studies. Data boundaries were restricted to a gate-to-gate scenario with a receiving capacity of 500 t WCP/d, and based on a new production unit being set up at the starch factory. The total production cost of each WCP utilization option was analyzed from the economic and environmental costs. Fermented animal feed was an economically attractive scenario, giving a higher net present value (NPV), lower investment cost and environmental impact, and a shorter payback period for the 10-year operational period. The selling price of mushrooms was the most sensitive parameter regarding the NPV, while the NPV for the price of fermented animal feed had the highest value in the best-case scenario.

  18. Gender Aspects of the Economic Payback of a Tuition-Charging Higher Education

    ERIC Educational Resources Information Center

    Baskakova, M. E.

    2004-01-01

    For many decades now the sphere of education in Russia has been considered to be among the most well off among other spheres of activity, from the standpoint of gender equality. One component of radical economic reforms in Russia in the 1990s was the transformation of education financing. During the reform years the number of students in higher…

  19. Camp Pendleton Saves 91% in Parking Lot Lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-01-01

    Case study describes how Camp Pendleton Marine Corps Base replaced high-pressure sodium (HPS) fixtures in one parking lot with high-efficiency induction fixtures for 91% savings in energy use and $5,700 in cost savings annually. This parking lot is estimated to have a simple payback of 2.9 years. Sitewide up-grades yielded annual savings of 1 million kWh.

  20. The Canonical Robot Command Language (CRCL).

    PubMed

    Proctor, Frederick M; Balakirsky, Stephen B; Kootbally, Zeid; Kramer, Thomas R; Schlenoff, Craig I; Shackleford, William P

    2016-01-01

    Industrial robots can perform motion with sub-millimeter repeatability when programmed using the teach-and-playback method. While effective, this method requires significant up-front time, tying up the robot and a person during the teaching phase. Off-line programming can be used to generate robot programs, but the accuracy of this method is poor unless supplemented with good calibration to remove systematic errors, feed-forward models to anticipate robot response to loads, and sensing to compensate for unmodeled errors. These increase the complexity and up-front cost of the system, but the payback in the reduction of recurring teach programming time can be worth the effort. This payback especially benefits small-batch, short-turnaround applications typical of small-to-medium enterprises, who need the agility afforded by off-line application development to be competitive against low-cost manual labor. To fully benefit from this agile application tasking model, a common representation of tasks should be used that is understood by all of the resources required for the job: robots, tooling, sensors, and people. This paper describes an information model, the Canonical Robot Command Language (CRCL), which provides a high-level description of robot tasks and associated control and status information.

  1. Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Geoffrey C.; Federspiel, Clifford

    Control software and wireless sensors designed for closed-loop, monitoring and control of IT equipment's inlet air temperatures in datacenters were evaluated and tested while other datacenter cooling best practices were implemented. The controls software and hardware along with each best practice were installed sequentially and evaluated using a measurement and verification procedure between each measure. The results show that the overall project eliminates 475,239 kWh per year, which is 21.3percent of the baseline energy consumption of the data center. The total project, including the best practices will save $42,772 per year and cost $134,057 yielding a simple payback of 3.1more » years. However, the control system alone eliminates 59.6percent of the baseline energy used to move air in the datacenter and 13.6percent of the baseline cooling energy, which is 15.2percent of the baseline energy consumption (see Project Approach, Task 1, below, for additional information) while keeping temperatures substantially within the limits recommended by ASHRAE. Savings attributed to the control system are $30,564 per year with a cost $56,824 for a simple payback of 1.9 years.« less

  2. Applications of thermal energy storage to process heat and waste heat recovery in the iron and steel industry

    NASA Technical Reports Server (NTRS)

    Katter, L. B.; Peterson, D. J.

    1978-01-01

    The system identified operates from the primary arc furnace evacuation system as a heat source. Energy from the fume stream is stored as sensible energy in a solid medium (packed bed). A steam-driven turbine is arranged to generate power for peak shaving. A parametric design approach is presented since the overall system design, at optimum payback is strongly dependent upon the nature of the electric pricing structure. The scope of the project was limited to consideration of available technology so that industry-wide application could be achieved by 1985. A search of the literature, coupled with interviews with representatives of major steel producers, served as the means whereby the techniques and technologies indicated for the specific site are extrapolated to the industry as a whole and to the 1985 time frame. The conclusion of the study is that by 1985, a national yearly savings of 1.9 million barrels of oil could be realized through recovery of waste heat from primary arc furnace fume gases on an industry-wide basis. Economic studies indicate that the proposed system has a plant payback time of approximately 5 years.

  3. 25th anniversary article: Rise to power--OPV-based solar parks.

    PubMed

    Krebs, Frederik C; Espinosa, Nieves; Hösel, Markus; Søndergaard, Roar R; Jørgensen, Mikkel

    2014-01-08

    A solar park based on polymer solar cells is described and analyzed with respect to performance, practicality, installation speed, and energy payback time. It is found that a high voltage installation where solar cells are all printed in series enables an installation rate in Watts installed per minute that far exceed any other PV technology in existence. The energy payback time for the practical installation of polymer solar cell foil on a wooden 250 square meter platform in its present form is 277 days when operated in Denmark and 180 days when operated in southern Spain. The installation and de-installation rate is above 100 m min⁻¹, which, with the present performance and web width, implies installation of >200 W min⁻¹. In comparison, this also exceeds the overall manufacturing speed of the polymer solar cell foil with a width of 305 mm which is currently 1 m min⁻¹ for complete encapsulated and tested foil. It is also significant that simultaneous installation and de-installation which enables efficient schemes for decommissioning and recycling is possible. It is highlighted where research efforts should most rationally be invested in order to make grid electricity from OPV a reality (and it is within reach).

  4. The Canonical Robot Command Language (CRCL)

    PubMed Central

    Proctor, Frederick M.; Balakirsky, Stephen B.; Kootbally, Zeid; Kramer, Thomas R.; Schlenoff, Craig I.; Shackleford, William P.

    2017-01-01

    Industrial robots can perform motion with sub-millimeter repeatability when programmed using the teach-and-playback method. While effective, this method requires significant up-front time, tying up the robot and a person during the teaching phase. Off-line programming can be used to generate robot programs, but the accuracy of this method is poor unless supplemented with good calibration to remove systematic errors, feed-forward models to anticipate robot response to loads, and sensing to compensate for unmodeled errors. These increase the complexity and up-front cost of the system, but the payback in the reduction of recurring teach programming time can be worth the effort. This payback especially benefits small-batch, short-turnaround applications typical of small-to-medium enterprises, who need the agility afforded by off-line application development to be competitive against low-cost manual labor. To fully benefit from this agile application tasking model, a common representation of tasks should be used that is understood by all of the resources required for the job: robots, tooling, sensors, and people. This paper describes an information model, the Canonical Robot Command Language (CRCL), which provides a high-level description of robot tasks and associated control and status information. PMID:28529393

  5. Waste Heat Recovery and Recycling in Thermal Separation Processes: Distillation, Multi-Effect Evaporation (MEE) and Crystallization Processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emmanuel A. Dada; Chandrakant B. Panchal; Luke K. Achenie

    Evaporation and crystallization are key thermal separation processes for concentrating and purifying inorganic and organic products with energy consumption over 1,000 trillion Btu/yr. This project focused on a challenging task of recovering low-temperature latent heat that can have a paradigm shift in the way thermal process units will be designed and operated to achieve high-energy efficiency and significantly reduce the carbon footprint as well as water footprint. Moreover, this project has evaluated the technical merits of waste-heat powered thermal heat pumps for recovery of latent heat from distillation, multi-effect evaporation (MEE), and crystallization processes and recycling into the process. Themore » Project Team has estimated the potential energy, economics and environmental benefits with the focus on reduction in CO2 emissions that can be realized by 2020, assuming successful development and commercialization of the technology being developed. Specifically, with aggressive industry-wide applications of heat recovery and recycling with absorption heat pumps, energy savings of about 26.7 trillion Btu/yr have been estimated for distillation process. The direct environmental benefits of this project are the reduced emissions of combustible products. The estimated major reduction in environmental pollutants in the distillation processes is in CO2 emission equivalent to 3.5 billion lbs/year. Energy consumption associated with water supply and treatments can vary between 1,900 kWh and 23,700 kWh per million-gallon water depending on sources of natural waters [US DOE, 2006]. Successful implementation of this technology would significantly reduce the demand for cooling-tower waters, and thereby the use and discharge of water treatment chemicals. The Project Team has also identified and characterized working fluid pairs for the moderate-temperature heat pump. For an MEE process, the two promising fluids are LiNO3+KNO3+NANO3 (53:28:19 ) and LiNO3+KNO3+NANO2(53:35:12). And for an H2O2 distillation process, the two promising fluids are Trifluoroethanol (TFE) + Triethylene Glycol Dimethyl ether (DMETEG) and Ammonia+ Water. Thermo-physical properties calculated by Aspen+ are reasonably accurate. Documentation of the installation of pilot-plants or full commercial units were not found in the literature for validating thermo-physical properties in an operating unit. Therefore, it is essential to install a pilot-scale unit to verify thermo-physical properties of working fluid pairs and validate the overall efficiency of the thermal heat pump at temperatures typical of distillation processes. For an HO2 process, the ammonia-water heat pump system is more compact and preferable than the TFE-DMETEG heat pump. The ammonia-water heat pump is therefore recommended for the H2O2 process. Based on the complex nature of the heat recovery system, we anticipated that capital costs could make investments financially unattractive where steam costs are low, especially where co-generation is involved. We believe that the enhanced heat transfer equipment has the potential to significantly improve the performance of TEE crystallizers, independent of the absorption heat-pump recovery system. Where steam costs are high, more detailed design/cost engineering will be required to verify the economic viability of the technology. Due to the long payback period estimated for the TEE open system, further studies on the TEE system are not warranted unless there are significant future improvements to heat pump technology. For the H2O2 distillation cycle heat pump waste heat recovery system, there were no significant process constraints and the estimated 5 years payback period is encouraging. We therefore recommend further developments of application of the thermal heat pump in the H2O2 distillation process with the focus on the technical and economic viability of heat exchangers equipped with the state-of-the-art enhancements. This will require additional funding for a prototype unit to validate enhanced thermal performances of heat transfer equipment, evaluate the fouling characteristics in field testing, and remove the uncertainty factors included in the estimated payback period for the H2O2 distillation system.« less

  6. Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting in Leavenworth, KS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myer, Michael; Kinzey, Bruce R.; Curry, Ku'uipo

    2011-05-06

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a commercial parking lot lighting application, under the U.S. Department of Energy (DOE) Solid-State Lighting Technology GATEWAY Demonstration Program. The parking lot is for customers and employees of a Walmart Supercenter in Leavenworth, Kansas and this installation represents the first use of the LED Parking Lot Performance Specification developed by the DOE’s Commercial Building Energy Alliance. The application is a parking lot covering more than a half million square feet, lighted primarily by light-emitting diodes (LEDs). Metal halide wall packs were installed along themore » building facade. This site is new construction, so the installed baseline(s) were hypothetical designs. It was acknowledged early on that deviating from Walmart’s typical design would reduce the illuminance on the site. Walmart primarily uses 1000W pulse-start metal halide (PMH) lamps. In order to provide a comparison between both typical design and a design using conventional luminaires providing a lower illuminance, a 400W PMH design was also considered. As mentioned already, the illuminance would be reduced by shifting from the PMH system to the LED system. The Illuminating Engineering Society of North America (IES) provides recommended minimum illuminance values for parking lots. All designs exceeded the recommended illuminance values in IES RP-20, some by a wider margin than others. Energy savings from installing the LED system compared to the different PMH systems varied. Compared to the 1000W PMH system, the LED system would save 63 percent of the energy. However, this corresponds to a 68 percent reduction in illuminance as well. In comparison to the 400W PMH system, the LED system would save 44 percent of the energy and provide similar minimum illuminance values at the time of relamping. The LED system cost more than either of the PMH systems when comparing initial costs. However, when the life-cycle costs from energy and maintenance were factored into the scenario, the LED system had lower costs at the end of a 10-year analysis period. The LED system had a 6.1 year payback compared to the 1000W PMH system and a 7.5 year payback versus the 400W PMH system. The costs reflect high initial cost for the LED luminaire, plus more luminaires and (subsequently) more poles for the LED system. The other major issue affecting cost effectiveness was that Leavenworth, Kansas has very low electricity costs. The melded rate for this site was $0.056 per kWh for electricity. However, if the national electricity rate of $0.1022/kWh was used the payback would change to between four and five years for the LED system. This demonstration met the GATEWAY requirements of saving energy, matching or improving illumination, and being cost effective. The project also demonstrated that the Commercial Building Energy Alliance (CBEA) specification works in practice. Walmart appreciated having an entire site lighted by LEDs to gain more experience with the technology. Walmart is reviewing the results of the demonstration as they consider their entire real estate portfolio.« less

  7. An assessment of the impact of the NHS Health Technology Assessment Programme.

    PubMed

    Hanney, S; Buxton, M; Green, C; Coulson, D; Raftery, J

    2007-12-01

    To consider how the impact of the NHS Health Technology Assessment (HTA) Programme should be measured. To determine what models are available and their strengths and weaknesses. To assess the impact of the first 10 years of the NHS HTA programme from its inception in 1993 to June 2003 and to identify the factors associated with HTA research that are making an impact. Main electronic databases from 1990 to June 2005. The documentation of the National Coordinating Centre for Health Technology Assessment (NCCHTA). Questionnaires to eligible researchers. Interviews with lead investigators. Case study documentation. A literature review of research programmes was carried out, the work of the NCCHTA was reviewed, lead researchers were surveyed and 16 detailed case studies were undertaken. Each case study was written up using the payback framework. A cross-case analysis informed the analysis of factors associated with achieving payback. Each case study was scored for impact before and after the interview to assess the gain in information due to the interview. The draft write-up of each study was checked with each respondent for accuracy and changed if necessary. The literature review identified a highly diverse literature but confirmed that the 'payback' framework pioneered by Buxton and Hanney was the most widely used and most appropriate model available. The review also confirmed that impact on knowledge generation was more easily quantified than that on policy, behaviour or especially health gain. The review of the included studies indicated a higher level of impact on policy than is often assumed to occur. The survey showed that data pertinent to payback exist and can be collected. The completed questionnaires showed that the HTA Programme had considerable impact in terms of publications, dissemination, policy and behaviour. It also showed, as expected, that different parts of the Programme had different impacts. The Technology Assessment Reports (TARs) for the National Institute for Health and Clinical Excellence (NICE) had the clearest impact on policy in the form of NICE guidance. Mean publications per project were 2.93 (1.98 excluding the monographs), above the level reported for other programmes. The case studies revealed the large diversity in the levels and forms of impacts and the ways in which they arise. All the NICE TARs and more than half of the other case studies had some impact on policy making at the national level whether through NICE, the National Screening Committee, the National Service Frameworks, professional bodies or the Department of Health. This underlines the importance of having a customer or 'receptor' body. A few case studies had very considerable impact in terms of knowledge production and in informing national and international policies. In some of these the principal investigator had prior expertise and/or a research record in the topic. The case studies confirmed the questionnaire responses but also showed how some projects led to further research. This study concluded that the HTA Programme has had considerable impact in terms of knowledge generation and perceived impact on policy and to some extent on practice. This high impact may have resulted partly from the HTA Programme's objectives, in that topics tend to be of relevance to the NHS and have policy customers. The required use of scientific methods, notably systematic reviews and trials, coupled with strict peer reviewing, may have helped projects publish in high-quality peer-reviewed journals. Further research should cover more detailed, comprehensive case studies, as well as enhancement of the 'payback framework'. A project that collated health research impact studies in an ongoing manner and analysed them in a consistent fashion would also be valuable.

  8. Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting at the I-35W Bridge, Minneapolis, MN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    2009-08-31

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology conducted in 2009 at the recently reconstructed I-35W bridge in Minneapolis, MN. The project was supported under the U.S. Department of Energy (DOE) Solid-State Lighting GATEWAY Technology Demonstration Program. Other participants in the demonstration project included the Minnesota Department of Transportation (Mn/DOT), Federal Highways Administration (FHWA), and BetaLED™ (a division of Ruud Lighting). Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. DOE has implemented a three-year evaluation of the LED luminaires in this installation in order to develop new longitudinalmore » field data on LED performance in a challenging, real-world environment. This document provides information through the initial phase of the I-35W bridge project, up to and including the opening of the bridge to the public and the initial feedback received on the LED lighting installation from bridge users. Initial findings of the evaluation are favorable, with minimum energy savings level of 13% for the LED installation relative to the simulated base case using 250W high-pressure sodium (HPS) fixtures. The LEDs had an average illuminance level of 0.91 foot candles compared to 1.29 fc for the HPS lamps. The LED luminaires cost $38,000 more than HPS lamps, yielding a lengthy payback period, however the bridge contractor had offered to include the LED luminaires as part of the construction package at no additional cost. One potentially significant benefit of the LEDs in this installation is avoiding rolling lane closures on the heavily-traveled interstate bridge for the purpose of relamping the HPS fixtures. Rolling lane closures involve multiple crew members and various maintenance and safety vehicles, diversion of traffic, as well as related administrative tasks (e.g., approvals, scheduling, etc.). Mn/DOT records show an average cost of relamping fixtures along interstate roadways of between $130-150 per pole. The previous bridge saw a lamp mortality rate of approximately 50% every two years, though the new bridge was designed to minimize many of the vibration issues. A voluntary Web-based feedback survey of nearly 500 self-described bridge users showed strong preference for the LED lighting - positive comments outnumbered negative ones by about five-to-one.« less

  9. Conducting retrospective impact analysis to inform a medical research charity’s funding strategies: the case of Asthma UK

    PubMed Central

    2013-01-01

    Background Debate is intensifying about how to assess the full range of impacts from medical research. Complexity increases when assessing the diverse funding streams of funders such as Asthma UK, a charitable patient organisation supporting medical research to benefit people with asthma. This paper aims to describe the various impacts identified from a range of Asthma UK research, and explore how Asthma UK utilised the characteristics of successful funding approaches to inform future research strategies. Methods We adapted the Payback Framework, using it both in a survey and to help structure interviews, documentary analysis, and case studies. We sent surveys to 153 lead researchers of projects, plus 10 past research fellows, and also conducted 14 detailed case studies. These covered nine projects and two fellowships, in addition to the innovative case studies on the professorial chairs (funded since 1988) and the MRC-Asthma UK Centre in Allergic Mechanisms of Asthma (the ‘Centre’) which together facilitated a comprehensive analysis of the whole funding portfolio. We organised each case study to capture whatever academic and wider societal impacts (or payback) might have arisen given the diverse timescales, size of funding involved, and extent to which Asthma UK funding contributed to the impacts. Results Projects recorded an average of four peer-reviewed journal articles. Together the chairs reported over 500 papers. All streams of funding attracted follow-on funding. Each of the various categories of societal impacts arose from only a minority of individual projects and fellowships. Some of the research portfolio is influencing asthma-related clinical guidelines, and some contributing to product development. The latter includes potentially major breakthroughs in asthma therapies (in immunotherapy, and new inhaled drugs) trialled by university spin-out companies. Such research-informed guidelines and medicines can, in turn, contribute to health improvements. The role of the chairs and the pioneering collaborative Centre is shown as being particularly important. Conclusions We systematically demonstrate that all types of Asthma UK’s research funding assessed are making impacts at different levels, but the main societal impacts from projects and fellowships come from a minority of those funded. Asthma UK used the study’s findings, especially in relation to the Centre, to inform research funding strategies to promote the achievement of impact. PMID:23651523

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, George

    VICE 2.0 is the second generation of the VICE financial model developed by the National Renewable Energy Laboratory for fleet managers to assess the financial soundness of converting their fleets to run on CNG. VICE 2.0 uses a number of variables for infrastructure and vehicles to estimate the business case for decision-makers when considering CNG as a vehicle fuel. Enhancements in version 2.0 include the ability to select the project type (vehicles and infrastructure or vehicle acquisitions only), and to decouple vehicle acquisition from the infrastructure investment, so the two investments may be made independently. Outputs now include graphical presentationsmore » of investment cash flow, payback period (simple and discounted), petroleum displacement (annual and cumulative), and annual greenhouse gas reductions. Also, the Vehicle Data are now built around several common conventionally fueled (gasoline and diesel) fleet vehicles. Descriptions of the various model sections and available inputs follow. Each description includes default values for the base-case business model, which was created so economic sensitivities can be investigated by altering various project parameters one at a time.« less

  11. Thermal Energy Storage using PCM for Solar Domestic Hot Water Systems: A Review

    NASA Astrophysics Data System (ADS)

    Khot, S. A.; Sane, N. K.; Gawali, B. S.

    2012-06-01

    Thermal energy storage using phase chase materials (PCM) has received considerable attention in the past two decades for time dependent energy source such as solar energy. From several experimental and theoretical analyses that have been made to assess the performance of thermal energy storage systems, it has been demonstrated that PCM-based systems are reliable and viable options. This paper covers such information on PCMs and PCM-based systems developed for the application of solar domestic hot water system. In addition, economic analysis of thermal storage system using PCM in comparison with conventional storage system helps to validate its commercial possibility. From the economic analysis, it is found that, PCM based solar domestic hot water system (SWHS) provides 23 % more cumulative and life cycle savings than conventional SWHS and will continue to perform efficiently even after 15 years due to application of non-metallic tank. Payback period of PCM-based system is also less compared to conventional system. In conclusion, PCM based solar water heating systems can meet the requirements of Indian climatic situation in a cost effective and reliable manner.

  12. Design and Analysis of Photovoltaic (PV) Power Plant at Different Locations in Malaysia

    NASA Astrophysics Data System (ADS)

    Islam, M. A.; Hasanuzzaman, M.; Rahim, N. A.

    2018-05-01

    Power generation from sun oriented vitality through a photovoltaic (PV) system is ended up prevalent over the world due to clean innovation. Geographical location of Malaysia is very favorable for PV power generation system. The Malaysian government has also taken different steps to increase the use of solar energy especially by emphasizing on building integrated PV (BIPV) system. Comparative study on the feasibility of BIPV installation at the different location of Malaysia is rarely found. On the other hand, solar cell temperature has a negative impact on the electricity generation. So in this study cost effectiveness and initial investment cost of building integrated grid connected solar PV power plant in different regions of Malaysia have been carried. The effect of PV solar cell temperature on the payback period (PBP) is also investigated. Highest PBP is 12.38 years at Selangor and lowest PBP is 9.70 years at Sabah (Kota Kinabalu). Solar cell temperature significantly increases the PBP of PV plant and highest 14.64% and lowest 13.20% raise of PBP are encountered at Penang and Sarawak respectively.

  13. Dual-objective optimization of organic Rankine cycle (ORC) systems using genetic algorithm: a comparison between basic and recuperative cycles

    NASA Astrophysics Data System (ADS)

    Hayat, Nasir; Ameen, Muhammad Tahir; Tariq, Muhammad Kashif; Shah, Syed Nadeem Abbas; Naveed, Ahmad

    2017-08-01

    Exploitation of low potential waste thermal energy for useful net power output can be done by manipulating organic Rankine cycle systems. In the current article dual-objectives (η_{th} and SIC) optimization of ORC systems [basic organic Rankine cycle (BORC) and recuperative organic Rankine cycle (RORC)] has been done using non-dominated sorting genetic algorithm (II). Seven organic compounds (R-123, R-1234ze, R-152a, R-21, R-236ea, R-245ca and R-601) have been employed in basic cycle and four dry compounds (R-123, R-236ea, R-245ca and R-601) have been employed in recuperative cycle to investigate the behaviour of two systems and compare their performance. Sensitivity analyses show that recuperation boosts the thermodynamic behaviour of systems but it also raises specific investment cost significantly. R-21, R-245ca and R-601 show attractive performance in BORC whereas R-601 and R-236ea in RORC. RORC, due to higher total investment cost and operation & maintenance costs, has longer payback periods as compared to BORC.

  14. A model to determine financial indicators for organic solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, Colin; Bender, Timothy; Lawryshyn, Yuri

    2009-11-15

    Organic solar cells are an emerging photovoltaic technology that is inexpensive and easy to manufacture, despite low efficiency and stability. A model, named TEEOS (Technical and Economic Evaluator for Organic Solar), is presented that evaluates organic solar cells for various solar energy applications in different geographic locations, in terms of two financial indicators, payback period and net present value (NPV). TEEOS uses SMARTS2 software to estimate broadband (280-4000 nm) spectral irradiance data and with the use of a cloud modification factor, predicts hourly irradiation in the absence of actual broadband irradiance data, which is scarce for most urban locations. Bymore » using the avoided cost of electricity, annual savings are calculated which produce the financial indicators. It is hoped that these financial indicators can help guide certain technical decisions regarding the direction of research for organic solar cells, for example, increasing efficiency or increasing the absorptive wavelength range. A sample calculation using solar hats is shown to be uneconomical, but a good example of large-scale organic PV production. (author)« less

  15. Development of cost-effective surfactant flooding technology, Quarterly report, October 1995--December 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, G.A.; Sepehrnoori, K.

    1995-12-31

    The objective of this research is to develop cost-effective surfactant flooding technology by using simulation studies to evaluate and optimize alternative design strategies taking into account reservoir characteristics process chemistry, and process design options such as horizontal wells. Task 1 is the development of an improved numerical method for our simulator that will enable us to solve a wider class of these difficult simulation problems accurately and affordably. Task 2 is the application of this simulator to the optimization of surfactant flooding to reduce its risk and cost. In this quarter, we have continued working on Task 2 to optimizemore » surfactant flooding design and have included economic analysis to the optimization process. An economic model was developed using a spreadsheet and the discounted cash flow (DCF) method of economic analysis. The model was designed specifically for a domestic onshore surfactant flood and has been used to economically evaluate previous work that used a technical approach to optimization. The DCF model outputs common economic decision making criteria, such as net present value (NPV), internal rate of return (IRR), and payback period.« less

  16. A quality-of-life-oriented endpoint for comparing therapies.

    PubMed

    Gelber, R D; Gelman, R S; Goldhirsch, A

    1989-09-01

    An endpoint, time without symptoms of disease and toxicity of treatment (TWiST), is defined to provide a single measure of length and quality of survival. Time with subjective side effects of treatment and time with unpleasant symptoms of disease are subtracted from overall survival time to calculate TWiST for each patient. The purpose of this paper is to describe the construction of this endpoint, and to elaborate on its interpretation for patient care decision-making. Estimating the distribution of TWiST using actuarial methods is shown by simulation studies to be biased as a result of induced dependency between TWiST and its censoring distribution. Considering the distribution of TWiST accumulated within a specified time from start of therapy, L, allows one to reduce this bias by substituting estimated TWiST for censored values and provides a method to evaluate the "payback" period for early toxic effects. Quantile distance plots provide graphical representations for treatment comparisons. The analysis of Ludwig Trial III evaluating toxic adjuvant therapies versus a no-treatment control group for postmenopausal women with node-positive breast cancer illustrates the methodology.

  17. Effect of a constant-level lighting control system on small offices with windows. Final technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edgar, L.

    To reduce energy consumption stemming from lighting, some of the fixtures in Army office buildings have been delamped and building energy managers have instituted the policy of turning lights off when not in use. Even with these measures, lighting is still one of the largest consumers of electricity. The current problem is to find ways to reduce the energy consumption of lighting systems when they are in use. The objectives of this research was to provide information on the performance and energy savings potential of constant level lighting (CLL) controls. Based on a review of product information, researchers selected themore » Conservolite Plus 20 for testing and installed it in 10 office spaces. After 4 months of operation, a survey of the office occupants revealed that they were satisfied with the CLL system. Although electrical cost savings were realized, the payback period varied greatly, depending on the cost of replacing old or inoperable lamps and ballasts. Before large scale installation of CLL systems, it is recommended that the power factor and harmonic distortion be monitored at a large facility.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chua, S.E.; Abito, G.F.; Berbano, M.C.

    A 1 MWth multi-crop dehydration plant using waste geothermal energy is being operated by the Philippine National Oil Company-Energy Development Corporation (PNOC-EDC) at one of the reinjection pads at the Southern Negros Geothermal Project (SNGP). The facility is composed of two heat exchange systems, seven modular dryers of three different designs, a processing and storage area, a laboratory for quality control tests and an office for general administration and other services. Products from the plant include copra (dried coconut meat), dried fruits, fish and squid, and other agricultural products. Pilot demonstration runs showed the techno-economic: viability of the drying plant.more » Calculated IRR for production of copra and fruits is 19.3 %, giving a payback period on capital investment of 4.2 years. Sustainability of the operation of the plant requires detailed logistical, production, and marketing plans for the assumed production mix. The facility, which is from a grant from the United Nations Development Programme, is proposed to be {open_quotes}turned over{close_quotes} to a PNOC-formed consortium of farmers cooperatives and associations for its continuous operation and management as a profitable business venture for the community.« less

  19. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lustbader, Jason Aaron; Kekelia, Bidzina; Tomerlin, Jeff

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers willmore » enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation with a reflective barrier to the thermal load reduction package resulted in a 53.3% reduction in the overall heat transfer coefficient.« less

  20. Long-Haul Truck Sleeper Heating Load Reduction Package for Rest Period Idling: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lustbader, Jason; Kekelia, Bidzina; Tomerlin, Jeff

    Annual fuel use for sleeper cab truck rest period idling is estimated at 667 million gallons in the United States, or 6.8% of long-haul truck fuel use. Truck idling during a rest period represents zero freight efficiency and is largely done to supply accessory power for climate conditioning of the cab. The National Renewable Energy Laboratory's CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck thermal management systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers willmore » enable smaller, lighter, and more cost-effective idle reduction solutions. In addition, if the fuel savings provide a one- to three-year payback period, fleet owners will be economically motivated to incorporate them. For candidate idle reduction technologies to be implemented by original equipment manufacturers and fleets, their effectiveness must be quantified. To address this need, several promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. Load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, conductive pathways, and efficient equipment. Technologies in each of these focus areas were investigated in collaboration with industry partners. The most promising of these technologies were then combined with the goal of exceeding a 30% reduction in HVAC loads. These technologies included 'ultra-white' paint, advanced insulation, and advanced curtain design. Previous testing showed more than a 35.7% reduction in air conditioning loads. This paper describes the overall heat transfer coefficient testing of this advanced load reduction technology package that showed more than a 43% reduction in heating load. Adding an additional layer of advanced insulation with a reflective barrier to the thermal load reduction package resulted in a 53.3% reduction in the overall heat transfer coefficient.« less

  1. Extended use of grey water for irrigating home gardens in an arid environment.

    PubMed

    Al-Ismaili, Abdulrahim M; Ahmed, Mushtaque; Al-Busaidi, Ahmed; Al-Adawi, Seif; Tandlich, Roman; Al-Amri, Mohammed

    2017-05-01

    The use of treated grey water (GW) for home gardens, peri-urban agriculture and landscaping is becoming popular in many water stressed countries such as Oman. This study aims to investigate the treatment efficacy, health and chemical concerns, cost-benefits and maintenance protocol of a GW treatment system as well as the effect of irrigation with GW on crop yield. Therefore, a decentralized homemade GW treatment system was installed in a newly constructed house in Muscat, Oman and studied over a 2-year period. The treated GW was found to be suitable for irrigation as per Omani standards. GW when mixed with kitchen effluent substituted the use of nutrient supplements for plants and did not show any harmful chemical or biological contamination. The capital cost of the system was around US $980, and the annual operating cost was US $78 with annual income and savings from the system being around US $572 indicating a payback period of nearly 2 years. It was found that the system required simple but regular maintenance particularly cleaning of the top layer of the filter. It can be concluded from this study that such a GW system should be technically, economically and environmentally feasible in Oman. Also, wider acceptance by the general public to the idea of GW reuse will help in mitigating the water shortage problem of the country to some extent.

  2. Energy Efficiency Opportunities in Highway Lodging Buildings: Development of 50% Energy Savings Design Technology Packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Wei; Gowri, Krishnan; Thornton, Brian A.

    2010-06-30

    This paper presents the process, methodology, and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document that provides specific recommendations for achieving 50% energy savings in roadside motels (highway lodging) above the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004. This 50% solution represents a further step toward realization of the U.S. Department of Energy’s net-zero energy building goal, and go beyond the 30% savings in the Advanced Energy Design Guide series (upon which this work was built). This work can serve as the technical feasibility study for the development of a 50%more » saving Advanced Energy Design Guide for highway lodging, and thus should greatly expedite the development process. The purpose of this design package is to provide user-friendly design assistance to designers, developers, and owners of highway lodging properties. It is intended to encourage energy-efficient design by providing prescriptive energy-efficiency recommendations for each climate zone that attains the 50% the energy savings target. This paper describes the steps that were taken to demonstrate the technical feasibility of achieving a 50% reduction in whole-building energy use with practical and commercially available technologies. The energy analysis results are presented, indicating the recommended energy-efficient measures achieved a national-weighted average energy savings of 55%, relative to Standard 90.1-2004. The cost-effectiveness of the recommended technology package is evaluated and the result shows an average simple payback of 11.3 years.« less

  3. Cost-benefit analysis of electronic medical record system at a tertiary care hospital.

    PubMed

    Choi, Jong Soo; Lee, Woo Baik; Rhee, Poong-Lyul

    2013-09-01

    Although Electronic Medical Record (EMR) systems provide various benefits, there are both advantages and disadvantages regarding its cost-effectiveness. This study analyzed the economic effects of EMR systems using a cost-benefit analysis based on the differential costs of managerial accounting. Samsung Medical Center (SMC) is a general hospital in Korea that developed an EMR system for outpatients from 2006 to 2008. This study measured the total costs and benefits during an 8-year period after EMR adoption. The costs include the system costs of building the EMR and the costs incurred in smoothing its adoption. The benefits included cost reductions after its adoption and additional revenues from both remodeling of paper-chart storage areas and medical transcriptionists' contribution. The measured amounts were discounted by SMC's expected interest rate to calculate the net present value (NPV), benefit-cost ratio (BCR), and discounted payback period (DPP). During the analysis period, the cumulative NPV and the BCR were US$3,617 thousand and 1.23, respectively. The DPP was about 6.18 years. Although the adoption of an EMR resulted in overall growth in administrative costs, it is cost-effective since the cumulative NPV was positive. The positive NPV was attributed to both cost reductions and additional revenues. EMR adoption is not so attractive to management in that the DPP is longer than 5 years at 6.18 and the BCR is near 1 at 1.23. However, an EMR is a worthwhile investment, seeing that this study did not include any qualitative benefits and that the paper-chart system was cost-centric.

  4. A Review of Education and Training for Officers (RETO). Volume 2. Career Progression.

    DTIC Science & Technology

    1978-06-30

    any control over the academic disciplines being pursued by scholarship students resulted in a few ROTC graduates with disciplines of no reasonable...direct application to the military environment. Providing scholarship winners a list of academic majors from which to choose and thereafter channel their... academic endeavors, would provide a better link between precommissioning education and known Army requirements. (2) introducing a "pay-back" option

  5. Process gas hear recovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, W.M.; Thurner, R.P.

    1977-01-01

    In considering the use of regenerative and recuperative heat exchangers for process-gas heat recovery general information regarding heat-exchanger effectiveness versus initial capital investment and operating costs is discussed. Specific examples for preheating combustion air for process furnaces and for using primary and secondary heat exchangers in conjunction with an air-pollution-control system for drying and curing ovens cover basic heat-exchanger design and application considerations as well as investment-payback factors.

  6. Critical Code: Software Producibility for Defense

    DTIC Science & Technology

    2010-01-01

    the hazard of a single system failing can often be associated with a much larger aggregate of systems, often spread across a wide geography. The...four words: fault, error, failure, and hazard . These are defined and illustrated in Box 4.2. Information Loss and Traceability As noted above, the...design information when payback is uncertain, diffuse , or most likely far in the future. A goal in formulating incentive models that motivate developer

  7. Sustainability Action Planning and Initiatives at Twentynine Palms Marine Corps Air Ground Combat Center (MCAGCC)

    DTIC Science & Technology

    2011-05-01

    Energy and water security/ independence; sustain leadership • Compliance and environmental stewardship (cannot impact training mission...reduction, with efforts underway and cogeneration opportunities 18.3% of energy consumed by facilities is produced or procured from renewable...payback timeframes of ɠ years on existing cogeneration plant and ɛ years on new cogeneration plant Renewable Energy • In FY2010, approximately 6.2% of

  8. Selling solar energy as a cash crop

    NASA Technical Reports Server (NTRS)

    Brantley, L. W.

    1978-01-01

    The paper considers solar energy equipment which, besides supplying energy for farmstead needs, would convert excess energy to a transportable form to sell to a power company. It is suggested that a concentrating two-axis tracking spheroidal collector would cost as little as $5/sq ft if mass produced. The proposed system uses 7854 sq ft of collector area (set in about one acre of land), and the cost payback is estimated.

  9. Techno-economic feasibility of waste biorefinery: Using slaughtering waste streams as starting material for biopolyester production.

    PubMed

    Shahzad, Khurram; Narodoslawsky, Michael; Sagir, Muhammad; Ali, Nadeem; Ali, Shahid; Rashid, Muhammad Imtiaz; Ismail, Iqbal Mohammad Ibrahim; Koller, Martin

    2017-09-01

    The utilization of industrial waste streams as input materials for bio-mediated production processes constitutes a current R&D objective not only to reduce process costs at the input side but in parallel, to minimize hazardous environmental emissions. In this context, the EU-funded project ANIMPOL elaborated a process for the production of polyhydroxyalkanoate (PHA) biopolymers starting from diverse waste streams of the animal processing industry. This article provides a detailed economic analysis of PHA production from this waste biorefinery concept, encompassing the utilization of low-quality biodiesel, offal material and meat and bone meal (MBM). Techno-economic analysis reveals that PHA production cost varies from 1.41 €/kg to 1.64 €/kg when considering offal on the one hand as waste, or, on the other hand, accounting its market price, while calculating with fixed costs for the co-products biodiesel (0.97 €/L) and MBM (350 €/t), respectively. The effect of fluctuating market prices for offal materials, biodiesel, and MBM on the final PHA production cost as well as the investment payback time have been evaluated. Depending on the current market situation, the calculated investment payback time varies from 3.25 to 4.5years. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Experience with ethylene plant computer control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nasi, M.; Darby, M.L.; Sourander, M.

    This article discusses the control strategies, results and opinions of management and operations of a computer based ethylene plant control system. The ethylene unit contains 9 cracking heaters, and its nameplate capacity is 200,000 tpa ethylene. Reports on control performance during different unit loading and using different feedstock types. By converting the yield and utility consumption benefits due to computer control into monetary units, the payback time of the system is less than 2 yrs.

  11. Sustainability-Related Publications: Calendar Years 2014 - 2015

    DTIC Science & Technology

    2016-03-03

    five 100 kW wind turbines . The best performing turbine assessed at a hub height of 37 m could provide 52% of the site’s annual electric power needs...with a payback of approxi- mately 18 to 19.6 years. However, extrapo- lated long-term wind speeds suggest the best performing turbine assessed could... Wind Resource Assessment: Center Strafford Training Center, http://acwc.sdp.sirsi.net/client/search/asset/1047667 The New Hampshire Army National

  12. Simplified energy design economics: Principles of economics applied to energy conservation and solar energy investments in buildings

    NASA Astrophysics Data System (ADS)

    Marshall, H. E.; Ruegg, R. T.; Wilson, F.

    1980-01-01

    Economic analysis techniques for evaluating alternative energy conservation investments in buildings are presented. Life cycle cost, benefit cost, savings to investment, payback, and rate of return analyses are explained and illustrated. The procedure for discounting is described for a heat pump investment. Formulas, tables of discount factors, and detailed instructions are provided to give all information required to make economic evaluations of energy conserving building designs.

  13. Survey State of the Art: Electrical Load Management Techniques and Equipment.

    DTIC Science & Technology

    1986-10-31

    automobiles and even appliances. Applications in the area of demand and energy management have been multifaceted, given the needs involved and rapid paybacks...copy of the programming to be reloaded into the controller at any time and by designing this module with erasable and reprogrammable memory, the...points and performs DDC programming is stored in (direct digital control) of output reprogrammable , permanent memory points. A RIM may accommodate up

  14. U.S. Energy Service Company Industry: Market Size and Project Performance from 1990-2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Peter; Goldman, Charles; Satchwell, Andrew

    2012-08-21

    The U.S. energy service company (ESCO) industry is an example of a private sector business model where energy savings are delivered to customers primarily through the use of performance-based contracts. This study was conceived as a snapshot of the ESCO industry prior to the economic slowdown and the introduction of federal stimulus funding mandated by enactment of the American Recovery and Reinvestment Act of 2009 (ARRA). This study utilizes two parallel analytic approaches to characterize ESCO industry and market trends in the U.S.: (1) a ?top-down? approach involving a survey of individual ESCOs to estimate aggregate industry activity and (2)more » a ?bottom-up? analysis of a database of ~;;3,250 projects (representing over $8B in project investment) that reports market trends including installed EE retrofit strategies, project installation costs and savings, project payback times, and benefit-cost ratios over time. Despite the onset of a severe economic recession, the U.S. ESCO industry managed to grow at about 7percent per year between 2006 and 2008. ESCO industry revenues were about $4.1 billion in 2008 and ESCOs anticipate accelerated growth through 2011 (25percent per year). We found that 2,484 ESCO projects in our database generated ~;;$4.0 billion ($2009) in net, direct economic benefits to their customers. We estimate that the ESCO project database includes about 20percent of all U.S. ESCO market activity from 1990-2008. Assuming the net benefits per project are comparable for ESCO projects that are not included in the LBNL database, this would suggest that the ESCO industry has generated ~;;$23 billion in net direct economic benefits for customers at projects installed between 1990 and 2008. There is empirical evidence confirming that the industry is evolving by installing more comprehensive and complex measures?including onsite generation and measures to address deferred maintenance?but this evolution has significant implications for customer project economics, especially at K-12 schools. We found that the median simple payback time has increased from 1.9 to 3.2 years in private sector projects since the early-to-mid 1990s and from 5.2 to 10.5 years in public sector projects for the same time period.« less

  15. The US Orphan Drug Act: rare disease research stimulator or commercial opportunity?

    PubMed

    Wellman-Labadie, Olivier; Zhou, Youwen

    2010-05-01

    This study investigates issues associated with the United States Orphan Drug Act. A comprehensive orphan drug database was compiled from FDA data and corporate annual reports of major pharmaceutical companies. Analysis allowed the generation of a descriptive orphan drug portrait as well as documentation of orphan drugs along their lifecycle. Currently, 2002 products have obtained orphan drug designation with 352 drugs obtaining FDA approval. Approximately 33% of orphan drugs are oncology products. On average, products obtain 1.7 orphan designations with approximately 70% obtaining a single designation. At least 9% of orphan drugs have reached blockbuster status with two-thirds having two or more designations. An additional 25 orphan drugs had sales exceeding US$ 100 million in 2008 alone. Since 1983, at least 14 previously discontinued products have been recycled as orphan drugs. The United States Orphan Drug Act has created issues which, in some cases, have led to commercial and ethical abuses. Orphan Drug Act reform is necessary but current incentives, including 7 year market exclusivity, should be maintained in order to favour patients as well as economic prosperity. Suggested reforms include price regulation, subsidy paybacks for profitable drugs and the establishment of an International Orphan Drug Office. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  16. 40 CFR 80.305 - How are credits generated during the time period 2000 through 2003?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Abt... averaging period. Va = Total volume of gasoline produced during the averaging period at the refinery (or for a foreign refinery, the total volume of gasoline produced during the averaging period at the...

  17. 40 CFR 80.305 - How are credits generated during the time period 2000 through 2003?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Abt... averaging period. Va = Total volume of gasoline produced during the averaging period at the refinery (or for a foreign refinery, the total volume of gasoline produced during the averaging period at the...

  18. Solar energy system economic evaluation for IBM System 3, Glendo, Wyoming

    NASA Technical Reports Server (NTRS)

    1980-01-01

    This analysis was based on the technical and economic models in f-chart design procedures with inputs based on the characteristics of the parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings, and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables was also investigated.

  19. City of Raleigh, Wilders Grove Service Center, Solid Waste Services Facility. Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert Cox; Bill Black; Battle, Fred

    Final Report for DOE Grant EE0002808. Grant award was for technology demonstration of geothermal energy systems. One of the major objectives identified for the demonstration portion of the grant was to prove the viability of Ground Source Heat Pump (GSHP) systems in significantly reducing energy usage of HVAC and domestic water heating systems compared to traditional systems. Data were monitored and conclusions drawn, including estimating payback timeframes and documenting lessons learned.

  20. Problems of Waste Management at Poultry Plants and Ways to Address Them

    NASA Astrophysics Data System (ADS)

    Lazareva, L. P.; Kostryakova, O. N.

    2017-11-01

    The paper analyzes scientific literature on manure recycling and systems of waste management at two poultry plants that use different technologies of poultry housing and manure disposal and calculates the volumes of waste generation for two plants. The authors suggest an economically and ecologically efficient manure utilization technology, consider the feasibility of replacing traditional fuel with the one produced by manure recycling and calculate expected profits and the payback time of equipment.

  1. Manned Orbital Transfer Vehicle (MOTV). Volume 5: Turnaround analysis

    NASA Technical Reports Server (NTRS)

    Boyland, R. E.; Sherman, S. W.; Morfin, H. W.

    1979-01-01

    The development of a low-cost reliable turnaround process to employ the MOTV in enhancing the utilization of the geosynchronous space region is analyzed. It is indicated that a routine effective turnaround/maintenance plan must make maximum use of flight data for maintenance planning, a high degree of test automation, and MOTV maintainability features in order to minimize tests, facilitate repair, and reduce manpower requirements. An effective turnaround plan provides a payback of reduced risks.

  2. Executive summary for increment A, B and G energy study at Forest Glen, Walter Reed Army Medical Center, Washington, DC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1984-04-18

    The purpose of this study is to determine the amount of energy being used, the cost of this energy, and to recommend projects that will reduce energy consumption for Buildings 101, 104, 107, 114, 116, 118, 119, 120, 122, 125 and 138, located in the Forest Glen Complex, which is part of the Walter Reed Army Medical Center (WRAMC). Executive Order No. 12003, 20 July 1977, established energy conservation goals for existing Federal facilities requiring a reduction of 20% in the average energy use in FY 85 from the average annual energy requirements in FY 75. The Energy Conservation Investmentmore » Program (ECIP) is a Military Construction funded program for retrofitting existing DOD facilities to make them more energy efficient and thus providing substantial savings in utility costs. Each project is assessed in terms of source energy saved, the value of the energy and the capital and operating costs of the changes. The ECIP guidance provides two criteria for evaluating energy saving opportunities. These are an energy/cost ratio (E/C) and a benefit/cost ratio (B/C). For FY 84 the E/C ratio must be 13 or more with a B/C greater than one. Beginning with FY 85, ECIP projects will be prioritized on the basis of the greatest life cycle payback as determined by the savings to investment ratio (SIR). Overall projects and discrete portions of projects must be life cycle cost effective (SIR equal to or greater than 1). All energy savings projected in FY 85 shall be based on full occupancy of the buildings in the study.« less

  3. Combined Space and Water Heating: Next Steps to Improved Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B. Schoenbauer; Bohac, D.; Huelman, P.

    2016-07-13

    A combined space- and water-heating (combi) system uses a high-efficiency direct-vent burner that eliminates safety issues associated with natural draft appliances. Past research with these systems shows that using condensing water heaters or boilers with hydronic air handling units can provide both space and water heating with efficiencies of 90% or higher. Improved controls have the potential to reduce complexity and improve upon the measured performance. This project demonstrates that controls can significantly benefit these first-generation systems. Laboratory tests and daily load/performance models showed that the set point temperature reset control produced a 2.1%–4.3% (20–40 therms/year) savings for storage andmore » hybrid water heater combi systems operated in moderate-load homes. The full modulation control showed additional savings over set point control (in high-load homes almost doubling the savings: 4%–5% over the no-control case). At the time of installation the reset control can be implemented for $200–$400, which would provide paybacks of 6–25 years for low-load houses and 3–15 years for high-load houses. Full modulation implementation costs would be similar to the outdoor reset and would provide paybacks of 5-½–20 years for low-load houses and 2-½–10 years for high-load houses.« less

  4. Potential fresh water saving using greywater in toilet flushing in Syria.

    PubMed

    Mourad, Khaldoon A; Berndtsson, Justyna C; Berndtsson, Ronny

    2011-10-01

    Greywater reuse is becoming an increasingly important factor for potable water saving in many countries. Syria is one of the most water scarce countries in the Middle East. However, greywater reuse is still not common in the country. Regulations and standards for greywater reuse are not available. Recently, however, several stakeholders have started to plan for greywater reuse. The main objective of this paper is to evaluate the potential for potable water saving by using greywater for toilet flushing in a typical Syrian city. The Sweida city in the southern part of Syria was chosen for this purpose. Interviews were made in order to reflect the social acceptance, water consumption, and the percentage of different indoor water uses. An artificial wetland (AW) and a commercial bio filter (CBF) were proposed to treat the greywater, and an economic analysis was performed for the treatment system. Results show that using treated greywater for toilet flushing would save about 35% of the drinking water. The economic analyses of the two proposed systems showed that, in the current water tariff, the payback period for AW and CBF in block systems is 7 and 52 years, respectively. However, this period will reduce to 3 and 21 years, respectively, if full water costs are paid by beneficiaries. Hence, introducing artificial wetlands in order to make greywater use efficient appears to be a viable alternative to save potable water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Evaluation of auxiliary power subsystems for gas engine heat pumps, phase 2

    NASA Astrophysics Data System (ADS)

    Rasmussen, R. W.; Wahlstedt, D. A.; Planer, N.; Fink, J.; Persson, E.

    1988-12-01

    The need to determine the practical, technical and economic viability for a stand-alone Gas Engine Heat Pump (GEHP) system capable of generating its own needed electricity is addressed. Thirty-eight reasonable design configurations were conceived based upon small-sized power conversion equipment that is either commercially available or close to emerging on the market. Nine of these configurations were analyzed due to their potential for low first cost, high conversion efficiency, availability or simplicity. It was found that electric consumption can be reduced by over 60 percent through the implementation of high efficiency, brushless, permanent magnet motors as fan and pump drivers. Of the nine selected configurations employing variable-speed fans, two were found to have simple incremental payback periods of 4.2 to 16 years, depending on the U.S. city chosen for analysis. Although the auxiliary power subsystem option is only marginally attractive from an economic standpoint, the increased gas load provided to the local gas utility may be sufficient to encourage further development. The ability of the system to operate completely disconnected from the electric power source may be a feature of high merit.

  6. Choice of information system for Russian companies

    NASA Astrophysics Data System (ADS)

    Demyanova, O. V.; Biktemirova, M. H.

    2018-05-01

    The relevance of work is caused by the importance of an integrated approach to automating the business processes of organizations. Understanding the relevance of the problem came to Russia with some delay, in comparison with the West. Recently the interest in information technologies, which are inseparably linked with a concept of an information system of the corporate level and capable to provide effective management of the entity, has grown. Also the modern models of information technologies allow one to put into practice methods of the game theory by means of which it is possible to count and predict important results and on its basis to make the right management decision. The purpose of this work was to choose an optimal information system and to research efficiency of its application for the pharmaceutical company Pharmstandard. Mathematical and marketing methods were used during the research. The choice of a certain corporate information system and calculation of efficiency of its usage and a payback period are the result of the work. Results of the conducted research can be used by the specialists of various industrial enterprises for development of the competitive activities in the sphere of strategic planning.

  7. Engineering Analysis and Economic Evaluation of the Synthesis of Composite CuO/ZnO/ZrO2 Nanocatalyst

    NASA Astrophysics Data System (ADS)

    Nandiyanto, A. B. D.; Hayati, W. R.; Aziz, T. A.; Ragadhita, R.; Abdullah, A. G.; Widiaty, I.

    2018-02-01

    The purpose of this study was to evaluate the synthesis process of composite CuO/ZnO/ZrO2 (CZZ) nanocatalyst. The CZZ nanocatalyst is used as a catalyst in the hydrogenation reaction, which is used to convert harmful CO2 gas into liquid fuels such as methanol. In this study, CZZ produced using the sol-gel autocombustion method was selected as a model of the production procedure. The evaluation was conducted into two factors: engineering and economic analysis. Engineering analysis was analyzed based on the available apparatuses and raw materials in online web. Then, these data were used and compared with the mass balance approximation. The economic analysis was done using several economic parameters, including such as gross margin, internal rate return, payback period, cumulative net value, break even point (BEP), profitability index on sales to investment. Engineering analysis showed the present method can be applied using available apparatuses and raw materials in market. Economic analysis result confirmed that the present project is profitable. The analysis concluded that the present project for the production of CZZ nanocatalyst is prospective in small scale industry and profitable (by positive values in all economic parameters).

  8. Feasibility Study Analysis of Establishing Archery Sports Special Place

    NASA Astrophysics Data System (ADS)

    Tarigan, U. P. P.; Mardhatillah, A.; Budiman, I.; Sembiring, A. C.; Ramadhan, M. S.

    2018-04-01

    This study essentially discusses the basic concepts related to the decision and process of selecting a sports archery business project in order to provide economic and social benefits over time. Archery sports is a sport that requires special skills, both accuracy, coordination mental training and improves the physical condition of the prime. In Medan, it's still a bit of practice archery, but many people love this sport. From the data collected, there are three locations where archery in the city of the field of the Sunggal Knights is located at Jl Tunggul Hitam no.1A, Kec. Medan Sunggal, Avros Educational Park Aval address at Avros Street No.60 Medan, and the Knights of Johor Archery Club which is located at Jl. The work of Darma Gg. Ujung Family, Medan Johor. Therefore a feasibility study was undertaken in establishing an archery sports place in the field. The aspects to be considered in making feasibility studies are market and marketing aspects, technical and equipment aspects, management aspects, legal aspects, economic and social aspects, and financial aspects. Financial analysis using own capital got Payback Period 3 years 5,8 months, Net Present Value Rp 11.684.026 and obtained Internal Rate of Return of 17%.

  9. Technical and Socioeconomic Potential of Biogas from Cassava Waste in Ghana.

    PubMed

    Kemausuor, Francis; Addo, Ahmad; Darkwah, Lawrence

    2015-01-01

    This study analyses technical potential and ex ante socioeconomic impacts of biogas production using cassava waste from agroprocessing plants. An analysis was performed for two biodigesters in two cassava processing communities in Ghana. The results showed that the two communities generate an excess of 4,500 tonnes of cassava peels per year. Using approximately 5% of the peels generated and livestock manure as inoculum can generate approximately 75,000 m(3) of gas with an estimated 60% methane content from two separate plants of capacities 500 m(3) and 300 m(3) in the two communities. If used internally as process fuel, the potential gas available could replace over 300 tonnes of firewood per year for cassava processing. The displacement of firewood with gas could have environmental, economic, and social benefits in creating sustainable development. With a 10 percent discount rate, an assumed 20-year biodigester will have a Net Present Value of approximately US$ 148,000, 7-year Payback Period, and an Internal Rate of Return of 18.7%. The project will create 10 full-time unskilled labour positions during the investment year and 4 positions during operation years.

  10. Energy Efficiency Improvement and Cost Saving Opportunities for Breweries: An ENERGY STAR(R) Guide for Energy and Plant Managers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galitsky, Christina; Martin, Nathan; Worrell, Ernst

    2003-09-01

    Annually, breweries in the United States spend over $200 million on energy. Energy consumption is equal to 38 percent of the production costs of beer, making energy efficiency improvement an important way to reduce costs, especially in times of high energy price volatility. After a summary of the beer making process and energy use, we examine energy efficiency opportunities available for breweries. We provide specific primary energy savings for each energy efficiency measure based on case studies that have implemented the measures, as well as references to technical literature. If available, we have also listed typical payback periods. Our findingsmore » suggest that given available technology, there are still opportunities to reduce energy consumption cost-effectively in the brewing industry. Brewers value highly the quality, taste and drinkability of their beer. Brewing companies have and are expected to continue to spend capital on cost-effective energy conservation measures that meet these quality, taste and drinkability requirements. For individual plants, further research on the economics of the measures, as well as their applicability to different brewing practices, is needed to assess implementation of selected technologies.« less

  11. Feasibility study of a solar domestic hot water system for Oliver Hall, the University of Kansas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, J.C.W.

    1985-01-01

    Solar water heating represents a low-temperature use of solar energy. It has been proven cost effective in residential applications with renewable energy tax credits. However, tax credits for solar application are not available for state owned buildings, which incur higher system costs and may not economically justify solar energy. The purpose of this project was to design a site assembled solar hot water heating system to reduce system costs. Oliver Hall, a dormitory building at the University of Kansas, was chosen for this research project. The optimum size of the solar system was determined via several different methods to bemore » approximately 1800 square feet. The site chosen for the location of solar arrays was a ground-mounting on the west side of the dormitory due to the adjacency to the mechanical room, ease of maintenance, and lower initial cost. System components and equipment were chosen as the product of performance, cost, maintenance and product life. After completion of the system design, the unit cost data for each component was collected and the initial system cost was estimated to be $49,244 which translates into a payback period of 16 years.« less

  12. The prospect of hazardous sludge reduction through gasification process

    NASA Astrophysics Data System (ADS)

    Hakiki, R.; Wikaningrum, T.; Kurniawan, T.

    2018-01-01

    Biological sludge generated from centralized industrial WWTP is classified as toxic and hazardous waste based on the Indonesian’s Government Regulation No. 101/2014. The amount of mass and volume of sludge produced have an impact in the cost to manage or to dispose. The main objective of this study is to identify the opportunity of gasification technology which can be applied to reduce hazardous sludge quantity before sending to the final disposal. This preliminary study covers the technical and economic assessment of the application of gasification process, which was a combination of lab-scale experimental results and assumptions based on prior research. The results showed that the process was quite effective in reducing the amount and volume of hazardous sludge which results in reducing the disposal costs without causing negative impact on the environment. The reduced mass are moisture and volatile carbon which are decomposed, while residues are fix carbon and other minerals which are not decomposed by thermal process. The economical simulation showed that the project will achieve payback period in 2.5 years, IRR value of 53 % and BC Ratio of 2.3. The further study in the pilot scale to obtain the more accurate design and calculations is recommended.

  13. Water Management Planning: A Case Study at Blue Grass Army Depot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solana, Amy E.; Mcmordie, Katherine

    2006-04-03

    Executive Order 13123, Greening the Government Through Efficient Energy Management, mandates an aggressive policy for reducing potable water consumption at federal facilities. Implementation guid¬ance from the U.S. Department of Energy (DOE) set a requirement for each federal agency to “reduce potable water usage by implementing life cycle, cost-effective water efficiency programs that include a water management plan, and not less than four Federal Energy Management Program (FEMP) Best Manage¬ment Practices (BMPs).” The objective of this plan is to gain full compliance with Executive Order 13123 and associated DOE implementation guidance on behalf of Blue Grass Army Depot (BGAD), Richmond, Kentucky.more » In accordance with this plan, BGAD must: • Incorporate the plan as a component of the Installation energy conservation plan • Investigate the water savings potential and life-cycle cost effectiveness of the Operations and Maintenance (O&M) and retrofit/replacement options associated with the ten FEMP BMPs • Put into practice all applicable O&M options • Identify retrofit/replacement options appropriate for implementation (based upon calculation of the simple payback periods) • Establish a schedule for implementation of applicable and cost-effective retrofit/replacement options.« less

  14. Energy performance of areas for urban development (Arkhangelsk is given as example)

    NASA Astrophysics Data System (ADS)

    Popova, Olga; Glebova, Yulia

    2017-01-01

    The present research provides an overview and analysis of the legal framework and the technology to increase energy save and energy efficiency. The challenges of the mentioned activities implementation in urban areas are revealed in the paper. A comparison was made of the principal methods of increasing energy efficiency that is based on payback period. The basic shortcomings of the methods used are found. The way of capital reproducing assets acquisition is proposed with consideration of the rate of wear and tear and upgrading of urban residential development. The present research aims at characterizing energy sustainability of urban areas for forming the information basis that identifies capital construction projects together within the urban area. A new concept - area energy sustainability is introduced in the study to use system-structural approach to energy saving and energy efficiency. Energy sustainability of the area as an integral indicator of the static characteristics of the territory is considered as a complex involving the following terms: energy security, energy intensity and energy efficiency dynamic indicators of all the components of the power system of the area. Dimensions and parameters of energy sustainability of the area are determined. Arkhangelsk is given as example.

  15. Technical and Socioeconomic Potential of Biogas from Cassava Waste in Ghana

    PubMed Central

    Kemausuor, Francis; Addo, Ahmad; Darkwah, Lawrence

    2015-01-01

    This study analyses technical potential and ex ante socioeconomic impacts of biogas production using cassava waste from agroprocessing plants. An analysis was performed for two biodigesters in two cassava processing communities in Ghana. The results showed that the two communities generate an excess of 4,500 tonnes of cassava peels per year. Using approximately 5% of the peels generated and livestock manure as inoculum can generate approximately 75,000 m3 of gas with an estimated 60% methane content from two separate plants of capacities 500 m3 and 300 m3 in the two communities. If used internally as process fuel, the potential gas available could replace over 300 tonnes of firewood per year for cassava processing. The displacement of firewood with gas could have environmental, economic, and social benefits in creating sustainable development. With a 10 percent discount rate, an assumed 20-year biodigester will have a Net Present Value of approximately US$ 148,000, 7-year Payback Period, and an Internal Rate of Return of 18.7%. The project will create 10 full-time unskilled labour positions during the investment year and 4 positions during operation years. PMID:26664752

  16. Case Study - Propane School Bus Fleets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laughlin, M; Burnham, A.

    As part of the U.S. Department of Energy’s (DOE’s) effort to deploy transportation technologies that reduce U.S. dependence on imported petroleum, this study examines five school districts, one in Virginia and four in Texas, successful use of propane school buses. These school districts used school buses equipped with the newly developed liquid propane injection system that improves vehicle performance. Some of the school districts in this study saved nearly 50% on a cost per mile basis for fuel and maintenance relative to diesel. Using Argonne National Laboratory’s Alternative Fuel Life-Cycle Environmental and Economic Transportation (AFLEET) Tool developed for the DOE’smore » Clean Cities program to help Clean Cities stakeholders estimate petroleum use, greenhouse gas (GHG) emissions, air pollutant emissions and cost of ownership of light-duty and heavy-duty vehicles, the results showed payback period ranges from 3—8 years, recouping the incremental cost of the vehicles and infrastructure. Overall, fuel economy for these propane vehicles is close to that of displaced diesel vehicles, on an energy-equivalent basis. In addition, the 110 propane buses examined demonstrated petroleum displacement, 212,000 diesel gallon equivalents per year, and GHG benefits of 770 tons per year.« less

  17. Utilities Privatization-Is the US Army on the Right Circuit?

    DTIC Science & Technology

    2009-04-29

    is interested, the DoD must use competitive procedures to make the selection. DoD must receive an amount equal to the fair market value (FMV) of the...Aid of Construction versus Fair Market Value Issue and Discussion The first utilities privatization issue existing today centers around the payment of...a 10 percent depreciation rate of the system value so the contract length of the pay-back is 10 years. The contractor’s interest rate or rate of

  18. Improving customer service on the phone: a multidimensional effort with a big payback.

    PubMed

    Brown, Sally

    2005-01-01

    Telephone communications are the first line of contact for new patients and established patients who require ongoing care. They also represent one of many Achilles' heels for practices. Poor handling of phones can be inefficient and costly. This article outlines The Vancouver Clinic's experience in viewing the problems, identifying the issues, and resolving them with the minimum of expense and personnel disruption. It documents the marked lowering of call abandonment rates and the decrease in call-to-answer times.

  19. Regional hospital improves efficiency with co-generation retrofit.

    PubMed

    Knutson, D; Anderson, L

    1999-11-01

    Feasibility analysis of the co-generation retrofit of the Red Deer Regional Hospital pointed to a reasonable payback of capital cost and increased efficiency in operation of the facility. Budget restrictions nearly stopped the project from proceeding. Innovative construction procedures proposed by the Facility Management Group, in particular, Mr Keith Metcalfe, Director of Maintenance, allowed a worthwhile project to reach successful completion. We feel that this model can perhaps be used by similar facilities in the future to achieve their energy efficiency goals.

  20. Advanced propulsion for LEO-Moon transport. 3: Transportation model. M.S. Thesis - California Univ.

    NASA Technical Reports Server (NTRS)

    Henley, Mark W.

    1992-01-01

    A simplified computational model of low Earth orbit-Moon transportation system has been developed to provide insight into the benefits of new transportation technologies. A reference transportation infrastructure, based upon near-term technology developments, is used as a departure point for assessing other, more advanced alternatives. Comparison of the benefits of technology application, measured in terms of a mass payback ratio, suggests that several of the advanced technology alternatives could substantially improve the efficiency of low Earth orbit-Moon transportation.

  1. Guidebook for solar process-heat applications

    NASA Astrophysics Data System (ADS)

    Fazzolare, R.; Mignon, G.; Campoy, L.; Luttmann, F.

    1981-01-01

    The potential for solar process heat in Arizona and some of the general technical aspects of solar, such as insolation, siting, and process analysis are explored. Major aspects of a solar plant design are presented. Collectors, storage, and heat exchange are discussed. Reducing hardware costs to annual dollar benefits is also discussed. Rate of return, cash flow, and payback are discussed as they relate to solar systems. Design analysis procedures are presented. The design cost optimization techniques using a yearly computer simulation of a solar process operation is demonstrated.

  2. 29 CFR 548.302 - Average earnings for period other than a workweek.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 3 2011-07-01 2011-07-01 false Average earnings for period other than a workweek. 548.302... LABOR REGULATIONS AUTHORIZATION OF ESTABLISHED BASIC RATES FOR COMPUTING OVERTIME PAY Interpretations Authorized Basic Rates § 548.302 Average earnings for period other than a workweek. (a) Section 548.3(b...

  3. A decision-making tool to determine economic feasibility and break-even prices for artisan cheese operations.

    PubMed

    Durham, Catherine A; Bouma, Andrea; Meunier-Goddik, Lisbeth

    2015-12-01

    Artisan cheese makers lack access to valid economic data to help them evaluate business opportunities and make important business decisions such as determining cheese pricing structure. The objective of this study was to utilize an economic model to evaluate the net present value (NPV), internal rate of return, and payback period for artisan cheese production at different annual production volumes. The model was also used to determine the minimum retail price necessary to ensure positive NPV for 5 different cheese types produced at 4 different production volumes. Milk type, cheese yield, and aging time all affected variable costs. However, aged cheeses required additional investment for aging space (which needs to be larger for longer aging times), as did lower yield cheeses (by requiring larger-volume equipment for pasteurization and milk handling). As the volume of milk required increased, switching from vat pasteurization to high-temperature, short-time pasteurization was necessary for low-yield cheeses before being required for high-yield cheeses, which causes an additional increase in investment costs. Because of these differences, high-moisture, fresh cow milk cheeses can be sold for about half the price of hard, aged goat milk cheeses at the largest production volume or for about two-thirds the price at the lowest production volume examined. For example, for the given model assumptions, at an annual production of 13,608kg of cheese (30,000 lb), a fresh cow milk mozzarella should be sold at a minimum retail price of $27.29/kg ($12.38/lb), whereas a goat milk Gouda needs a minimum retail price of $49.54/kg ($22.47/lb). Artisan cheese makers should carefully evaluate annual production volumes. Although larger production volumes decrease average fixed cost and improve production efficiency, production can reach volumes where it becomes necessary to sell through distributors. Because distributors might pay as little as 35% of retail price, the retail price needs to be higher to compensate. An artisan cheese company that has not achieved the recognition needed to achieve a premium price may not find distribution through distributors profitable. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Oil Bypass Filter Technology Evaluation - Third Quarterly Report, April--June 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurence R. Zirker; James E. Francfort

    2003-08-01

    This Third Quarterly report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy’s FreedomCAR & Vehicle Technologies Program. Eight full-size, four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass filter systems from the PuraDYN Corporation. The reported engine lubricating oil-filtering capability (down to 0.1 microns) and additive package of the bypass filter system is intended to extend oil-drain intervals. To validate the extended oil-drain intervals, an oil-analysis regime monitors the presence of necessary additives inmore » the oil, detects undesirable contaminants and engine wear metals, and evaluates the fitness of the oil for continued service. The eight buses have accumulated 185,000 miles to date without any oil changes. The preliminary economic analysis suggests that the per bus payback point for the oil bypass filter technology should be between 108,000 miles when 74 gallons of oil use is avoided and 168,000 miles when 118 gallons of oil use is avoided. As discussed in the report, the variation in the payback point is dependant on the assumed cost of oil. In anticipation of also evaluating oil bypass systems on six Chevrolet Tahoe sport utility vehicles, the oil is being sampled on the six Tahoes to develop an oil characterization history for each engine.« less

  5. Reliability, return periods, and risk under nonstationarity

    NASA Astrophysics Data System (ADS)

    Read, Laura K.; Vogel, Richard M.

    2015-08-01

    Water resources design has widely used the average return period as a concept to inform management and communication of the risk of experiencing an exceedance event within a planning horizon. Even though nonstationarity is often apparent, in practice hydrologic design often mistakenly assumes that the probability of exceedance, p, is constant from year to year which leads to an average return period To equal to 1/p; this expression is far more complex under nonstationarity. Even for stationary processes, the common application of an average return period is problematic: it does not account for planning horizon, is an average value that may not be representative of the time to the next flood, and is generally not applied in other areas of water planning. We combine existing theoretical and empirical results from the literature to provide the first general, comprehensive description of the probabilistic behavior of the return period and reliability under nonstationarity. We show that under nonstationarity, the underlying distribution of the return period exhibits a more complex shape than the exponential distribution under stationary conditions. Using a nonstationary lognormal model, we document the increased complexity and challenges associated with planning for future flood events over a planning horizon. We compare application of the average return period with the more common concept of reliability and recommend replacing the average return period with reliability as a more practical way to communicate event likelihood in both stationary and nonstationary contexts.

  6. Evaluation of empowerment program to increase production capacity of fishery processing business in Semarang City, Indonesia

    NASA Astrophysics Data System (ADS)

    Swastawati, F.; Roessali, W.; Wijayanti, I.; Anggo, A. D.

    2018-01-01

    This study aims to evaluate the empowerment program to increase the production capacity of fishery product processing. Empowerment program was the implementation and utilization of science and technology in the area (IPTEKDA) LIPI Indonesia for Higher Education. Activity carried out in 2016 on fish processing industry “Lumintu Group”. Implementation of activities includes the transfer of technology to increase production capacity, business capital assistance in the form of production equipment, production assistance, and business management. This study uses qualitative, descriptive analysis, data collection with observation, interviews, and questionnaires. The results showed that the total number of active members was 24 people, 50% of the members specially cultivated the smoked fish that is the type of Catfish (Arius thalassinus) and Stingray (Dasyatis sp), while 45.83% of members processed boneless milkfish, and 4,17% produce salted fish. Increased average production scale of 31.82% in smoked fish business, 12.4% in boneless milkfish and 38.89% in salted fish business. Willingness to return capital in the good category, meaning that all members were able to carry out the schedule of relative payback on time. Approximately 83.3% of the group members felt that the program that followed had greatly assisted in increasing the scale of business but hoped to improve skills in terms of processing and marketing.

  7. Method for detection and correction of errors in speech pitch period estimates

    NASA Technical Reports Server (NTRS)

    Bhaskar, Udaya (Inventor)

    1989-01-01

    A method of detecting and correcting received values of a pitch period estimate of a speech signal for use in a speech coder or the like. An average is calculated of the nonzero values of received pitch period estimate since the previous reset. If a current pitch period estimate is within a range of 0.75 to 1.25 times the average, it is assumed correct, while if not, a correction process is carried out. If correction is required successively for more than a preset number of times, which will most likely occur when the speaker changes, the average is discarded and a new average calculated.

  8. 40 CFR Table 2 to Subpart Kkkkk of... - Operating Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Maintain the average scrubber pressure drop for each 3-hour block period at or above the average pressure drop established during the performance test; andb. Maintain the average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test...

  9. Cost-Benefit Analysis of Telemedicine Systems/Units in Greek Remote Areas.

    PubMed

    Kouskoukis, Marios-Nikolaos; Botsaris, Charalambos

    2017-06-01

    Telemedicine units and information technology systems provide special healthcare services to remote populations using telecommunication technology, in order to reduce or even remove the usual and typical face-to-face contact between doctor and patient. This innovative approach to medical care delivery has been expanding for several years and currently covers various medical specialties. To facilitate installation of telemedicine systems/units in Greek remote areas, this article presents results of a cost-benefit analysis for two Greek islands, Patmos and Leros, using specific economic criteria. Net present value (NPV), internal rate of return (IRR), and payback period were calculated, in order to monetize the economic benefits and the costs savings, estimate the depreciation of each project, and highlight the social benefits. Costs were reduced (through saved air medical transportations) by €19,005 for Patmos and €78,225 for Leros each year. NPV and IRR were positive; NPV was €29,608 for Patmos and €293,245 for Leros, and IRR was 21.5% for Patmos and 140.5% for Leros. Each project depreciated faster than the 5-year life-cycle period, and specifically in 3.13 years for Patmos and in 0.70 years for Leros. The establishment of telemedicine systems/units in Patmos and Leros was evaluated and assessed positively, with large savings, economical and social, gained by reducing or even removing the face-to-face contact between doctor and patient. Telemedicine systems/units seem to be a promising solution, especially in Greece, where the problem of primary healthcare services in remote/inaccessible areas is of great concern.

  10. Evolution of the U.S. Energy Service Company Industry: Market Size and Project Performance from 1990-2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Peter; Goldman, Charles A.; Satchwell, Andrew

    2012-05-08

    The U.S. energy service company (ESCO) industry is an example of a private sector business model where energy savings are delivered to customers primarily through the use of performance-based contracts. This study was conceived as a snapshot of the ESCO industry prior to the economic slowdown and the introduction of federal stimulus funding mandated by enactment of the American Recovery and Reinvestment Act of 2009 (ARRA). This study utilizes two parallel analytic approaches to characterize ESCO industry and market trends in the U.S.: (1) a “top-down” approach involving a survey of individual ESCOs to estimate aggregate industry activity and (2)more » a “bottom-up” analysis of a database of -3,265 projects (representing over $8B in project investment) that reports market trends including installed EE retrofit strategies, project installation costs and savings, project payback times, and benefit-cost ratios over time. Despite the onset of an economic recession, the U.S. ESCO industry managed to grow at about 7% per year between 2006 and 2008. ESCO industry revenues are relatively small compared to total U.S. energy expenditures (about $4.1 billion in 2008), but ESCOs anticipated accelerated growth through 2011 (25% per year). We found that 2,484 ESCO projects in our database generated -$4.0 billion ($2009) in net, direct economic benefits to their customers. We estimate that the ESCO project database includes about 20% of all U.S. ESCO market activity from 1990-2008. Assuming the net benefits per project are comparable for ESCO projects that are not included in the LBNL database, this would suggest that the ESCO industry has generated -$23 billion in net direct economic benefits for customers at projects installed between 1990 and 2008. We found that nearly 85% of all public and institutional projects met or exceeded the guaranteed level of savings. We estimated that a typical ESCO project generated $1.5 dollars of direct benefits for every dollar of customer investment. There is empirical evidence confirming that the industry is responding to customer demand by installing more comprehensive and complex measures—including onsite generation and measures to address deferred maintenance—but this evolution has significant implications for customer project economics, especially at K-12 schools. We found that the median simple payback time has increased from 1.9 to 3.2 years in private sector projects since the early-to-mid 1990s and from 5.2 to 10.5 years in public sector projects for the same time period.« less

  11. 40 CFR Table 2 to Subpart Jjjjj of... - Operating Limits

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Kiln equipped with a WS a. Maintain the average scrubber pressure drop for each 3-hour block period at... average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test; and c. Maintain the average scrubber liquid flow rate for each 3-hour...

  12. 40 CFR Table 2 to Subpart Jjjjj of... - Operating Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Kiln equipped with a WS a. Maintain the average scrubber pressure drop for each 3-hour block period at... average scrubber liquid pH for each 3-hour block period at or above the average scrubber liquid pH established during the performance test; and c. Maintain the average scrubber liquid flow rate for each 3-hour...

  13. Financial modeling in medicine: cash flow, basic metrics, the time value of money, discount rates, and internal rate of return.

    PubMed

    Lexa, Frank James; Berlin, Jonathan W

    2005-03-01

    In this article, the authors cover tools for financial modeling. Commonly used time lines and cash flow diagrams are discussed. Commonly used but limited terms such as payback and breakeven are introduced. The important topics of the time value of money and discount rates are introduced to lay the foundation for their use in modeling and in more advanced metrics such as the internal rate of return. Finally, the authors broach the more sophisticated topic of net present value.

  14. JT8D engine performance retention

    NASA Technical Reports Server (NTRS)

    James, A. D.; Weisel, D. R.

    1981-01-01

    The attractive performance retention characteristics of the JT8D engine are described. Because of its moderate bypass ratio and turbine temperature, and stiff structural design, the performance retention versus flight cycles of the JT8D engine sets a standard that is difficult for other engines to equal. In addition, the significant benefits of refurbishment of the JT8D engine are presented. Cold section refurbishment offers thrust specific fuel consumption improvements of up to 2 percent and payback in less than a year, making a very attractive investment option for the airlines.

  15. Progress of solar technology and potential farm uses

    NASA Astrophysics Data System (ADS)

    Heid, W. G., Jr.; Trotter, W. K.

    1982-09-01

    The efficient use of solar energy on farms for space heating and cooling of livestock buildings, drying crops, and heating farm homes is discussed. Low cost, homemade solar collectors, having multiple uses and a payback of less than 5 years, are the most popular systems. In contrast, most commercially produced systems are still too expensive for agricultural uses, partly because they fail to qualify for tax credits as large as those allowed for residential uses. The solar industry has shown little interest in marketing the low cost technologies specifically developed for agriculture.

  16. Cost of capital to the hospital sector.

    PubMed

    Sloan, F A; Valvona, J; Hassan, M; Morrisey, M A

    1988-03-01

    This paper provides estimates of the cost of equity and debt capital to for-profit and non-profit hospitals in the U.S. for the years 1972-83. The cost of equity is estimated using, alternatively, the Capital Asset Pricing Model and Arbitrage Pricing Theory. We find that the cost of equity capital, using either model, substantially exceeded anticipated inflation. The cost of debt capital was much lower. Accounting for the corporate tax shield on debt and capital paybacks by cost-based insurers lowered the net cost of capital to hospitals.

  17. Hill Problem Analytical Theory to the Order Four. Application to the Computation of Frozen Orbits around Planetary Satellites

    NASA Technical Reports Server (NTRS)

    Lara, Martin; Palacian, Jesus F.

    2007-01-01

    Frozen orbits of the Hill problem are determined in the double averaged problem, where short and long period terms are removed by means of Lie transforms. The computation of initial conditions of corresponding quasi periodic solutions in the non-averaged problem is straightforward for the perturbation method used provides the explicit equations of the transformation that connects the averaged and non-averaged models. A fourth order analytical theory reveals necessary for the accurate computation of quasi periodic, frozen orbits.

  18. Influence of mobile phone traffic on base station exposure of the general public.

    PubMed

    Joseph, Wout; Verloock, Leen

    2010-11-01

    The influence of mobile phone traffic on temporal radiofrequency exposure due to base stations during 7 d is compared for five different sites with Erlang data (representing average mobile phone traffic intensity during a period of time). The time periods of high exposure and high traffic during a day are compared and good agreement is obtained. The minimal required measurement periods to obtain accurate estimates for maximal and average long-period exposure (7 d) are determined. It is shown that these periods may be very long, indicating the necessity of new methodologies to estimate maximal and average exposure from short-period measurement data. Therefore, a new method to calculate the fields at a time instant from fields at another time instant using normalized Erlang values is proposed. This enables the estimation of maximal and average exposure during a week from short-period measurements using only Erlang data and avoids the necessity of long measurement times.

  19. Commercial launch systems: A risky investment?

    NASA Astrophysics Data System (ADS)

    Dupnick, Edwin; Skratt, John

    1996-03-01

    A myriad of evolutionary paths connect the current state of government-dominated space launch operations to true commercial access to space. Every potential path requires the investment of private capital sufficient to fund the commercial venture with a perceived risk/return ratio acceptable to the investors. What is the private sector willing to invest? Does government participation reduce financial risk? How viable is a commercial launch system without government participation and support? We examine the interplay between various forms of government participation in commercial launch system development, alternative launch system designs, life cycle cost estimates, and typical industry risk aversion levels. The boundaries of this n-dimensional envelope are examined with an ECON-developed business financial model which provides for the parametric assessment and interaction of SSTO design variables (including various operational scenarios with financial variables including debt/equity assumptions, and commercial enterprise burden rates on various functions. We overlay this structure with observations from previous ECON research which characterize financial risk aversion levels for selected industrial sectors in terms of acceptable initial lump-sum investments, cumulative investments, probability of failure, payback periods, and ROI. The financial model allows the construction of parametric tradeoffs based on ranges of variables which can be said to actually encompass the ``true'' cost of operations and determine what level of ``true'' costs can be tolerated by private capitalization.

  20. Tracking blood products in blood centres using radio frequency identification: a comprehensive assessment.

    PubMed

    Davis, Rodeina; Geiger, Bradley; Gutierrez, Alfonso; Heaser, Julie; Veeramani, Dharmaraj

    2009-07-01

    Radio frequency identification (RFID) can be a key enabler for enhancing productivity and safety of the blood product supply chain. This article describes a systematic approach developed by the RFID Blood Consortium for a comprehensive feasibility and impact assessment of RFID application in blood centre operations. Our comprehensive assessment approach incorporates process-orientated and technological perspectives as well as impact analysis. Assessment of RFID-enabled process redesign is based on generic core processes derived from the three participating blood centres. The technological assessment includes RFID tag readability and performance evaluation, testing of temperature and biological effects of RF energy on blood products, and RFID system architecture design and standards. The scope of this article is limited to blood centre processes (from donation to manufacturing/distribution) for selected mainstream blood products (red blood cells and platelets). Radio frequency identification can help overcome a number of common challenges and process inefficiencies associated with identification and tracking of blood products. High frequency-based RFID technology performs adequately and safely for red blood cell and platelet products. Productivity and quality improvements in RFID-enabled blood centre processes can recoup investment cost in a 4-year payback period. Radio frequency identification application has significant process-orientated and technological implications. It is feasible and economically justifiable to incorporate RFID into blood centre processes.

  1. Feed-in tariff structure development for photovoltaic electricity and the associated benefits for the Kingdom of Bahrain

    NASA Astrophysics Data System (ADS)

    Haji, Shaker; Durazi, Amal; Al-Alawi, Yaser

    2018-05-01

    In this study, the feed-in tariff (FIT) scheme was considered to facilitate an effective introduction of renewable energy in the Kingdom of Bahrain. An economic model was developed for the estimation of feasible FIT rates for photovoltaic (PV) electricity on a residential scale. The calculations of FIT rates were based mainly on the local solar radiation, the cost of a grid-connected PV system, the operation and maintenance cost, and the provided financial support. The net present value and internal rate of return methods were selected for model evaluation with the guide of simple payback period to determine the cost of energy and feasible FIT rates under several scenarios involving different capital rebate percentages, loan down payment percentages, and PV system costs. Moreover, to capitalise on the FIT benefits, its impact on the stakeholders beyond the households was investigated in terms of natural gas savings, emissions cutback, job creation, and PV-electricity contribution towards the energy demand growth. The study recommended the introduction of the FIT scheme in the Kingdom of Bahrain due to its considerable benefits through a setup where each household would purchase the PV system through a loan, with the government and the electricity customers sharing the FIT cost.

  2. Technical and economic analysis use of flare gas into alternative energy as a breakthrough in achieving zero routine flaring

    NASA Astrophysics Data System (ADS)

    Petri, Y.; Juliza, H.; Humala, N.

    2018-03-01

    The activity of exploring natural oil and gas will produce gas flare 0.584 MMSCFD. A gas flare is the combustion of gas remaining to avoid poisonous gas like H2S and CO which is very dangerous for human and environmental health. The combustion can bring about environmental pollution and losses because it still contains valuable energy. It needs the policy to encourage the use of flare gas with Zero Routine Flaring and green productivity to reduce waste and pollution. The objective of the research was to determine the use of gas flare so that it will have economic value and can achieve Zero Routine Flaring. It was started by analysing based on volume or rate and composition gas flare was used to determine technical feasibility, and the estimation of the gas reserves as the determination of the economy of a gas well. The results showed that the use of flare gas as fuel for power generation feasible to be implemented technically and economically with Internal Rate of Return (IRR) 19.32% and the Payback Period (PP) 5 year. Thus, it can increase gas flare value economically and can achieve a breakthrough in Zero Routine Flaring.

  3. Thermo Dynamics and Economics Evaluations: Substitution of the Extraction Steam with the Wasted Heat of Flue Gas

    NASA Astrophysics Data System (ADS)

    Hao, Lifen; Qiu, Lixia; Li, Jinping; Li, Dongxiong

    2018-01-01

    A new heat supplying system is proposed that utilizes the exhausted gas of the boiler to substitute the extraction steam from the turbine as the driving force for the adsorption heat pump regarding the recovery of the condensation heat of power plant. However, our system is not subject to the low efficiency of wasted heat utilization due to the low temperature of flue gas, which hence possesses higher performance in COP factors in the utilization of heat than that of the conventional techniques of using flues gas, so the amount of extracted gas from turbine can be reduced and the power generate rate be enhanced. Subsequently, detailed evaluation of the performance of this system in the point of views of thermodynamics and economics are presented in this work. For the instance of a 330 MW heat supply unit, 5 sample cities are chosen to demonstrate and confirm our economic analysis. It is revealed that when the heating coefficient of the heat pump is 1.8, the investment payback periods for these 5 cities are within the range of 2.4 to 4.8 years, which are far below the service year of the heat pump, demonstrating remarkable economic benefits for our system.

  4. An Experimental Study of Briquetting Process of Torrefied Rubber Seed Kernel and Palm Oil Shell.

    PubMed

    Hamid, M Fadzli; Idroas, M Yusof; Ishak, M Zulfikar; Zainal Alauddin, Z Alimuddin; Miskam, M Azman; Abdullah, M Khalil

    2016-01-01

    Torrefaction process of biomass material is essential in converting them into biofuel with improved calorific value and physical strength. However, the production of torrefied biomass is loose, powdery, and nonuniform. One method of upgrading this material to improve their handling and combustion properties is by densification into briquettes of higher density than the original bulk density of the material. The effects of critical parameters of briquetting process that includes the type of biomass material used for torrefaction and briquetting, densification temperature, and composition of binder for torrefied biomass are studied and characterized. Starch is used as a binder in the study. The results showed that the briquette of torrefied rubber seed kernel (RSK) is better than torrefied palm oil shell (POS) in both calorific value and compressive strength. The best quality of briquettes is yielded from torrefied RSK at the ambient temperature of briquetting process with the composition of 60% water and 5% binder. The maximum compressive load for the briquettes of torrefied RSK is 141 N and the calorific value is 16 MJ/kg. Based on the economic evaluation analysis, the return of investment (ROI) for the mass production of both RSK and POS briquettes is estimated in 2-year period and the annual profit after payback was approximately 107,428.6 USD.

  5. Waste management in the meat processing industry: Conversion of paunch and DAF sludge into solid fuel.

    PubMed

    Hamawand, Ihsan; Pittaway, Pam; Lewis, Larry; Chakrabarty, Sayan; Caldwell, Justin; Eberhard, Jochen; Chakraborty, Arpita

    2017-02-01

    This article addresses the novel dewatering process of immersion-frying of paunch and dissolved air flotation (DAF) sludge to produce high energy pellets. Literature have been analysed to address the feasibility of replacing conventional boiler fuel at meat processing facilities with high energy paunch-DAF sludge pellets (capsules). The value proposition of pelleting and frying this mixture into energy pellets is based on a Cost-Benefit Analysis (CBA). The CBA is based on information derived from the literature and consultation with the Australian Meat Processing Industry. The calorific properties of a mixture of paunch cake solids and DAF sludge were predicted from literature and industry consultation to validate the product. This study shows that the concept of pelletizing and frying paunch is economically feasible. The complete frying and dewatering of the paunch and DAF sludge mixture produces pellets with energy content per kilogram equivalent to coal. The estimated cost of this new product is half the price of coal and the payback period is estimated to be between 1.8 and 3.2years. Further research is required for proof of concept, and to identify the technical challenges associated with integrating this technology into existing meat processing plants. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  6. Management and Feasibility Analysis of Smoked Fish Business in Ambon

    NASA Astrophysics Data System (ADS)

    Nanlohy, Hellen; Apituley, Yolanda M. T. N.; Tapotubun, Alfonsina M.; Reiuwpassa, Frederik; Matrutty, Theodora E. A. A.

    2017-10-01

    This research aims to examine management and feasibility aspects of smoked fish business in Ambon. By using survey, this research focused on smoked fish business in Negeri Hative Kecil and Silale, known as dried fish producer villages.Primary and secondary data collected by using interview, observation, and recording. Analysis methods used are qualitative descriptive analysis and business feasibility analysis covers NPV, Payback Period (PP), and Break Even Point (BEP). The result shows that most of the smoked fish businessmen do not apply the proper management in their business. Two to three people do all the works (from production to marketing) without a clear job description. Feasibility analysis for smoked fish business in Negeri Hative Kecil shows that NPV is 21.501.053,- PP is 58 days, and Benefit Cost Ratio (B/C) is 1,06. BEP Production is 1,455 kg, and BEP Price is IDR 19,941, while the feasibility analysis for smoked fish business in Desa Silale shows that NPV is 30.745.837,-, PP is 24 days and Benefit Cost Ratio (B/C) is 1,41. BEP Production is 988 kg, and BEP Price is IDR 7,966. Based on the result, the two smoked fish business in Ambon is feasible to be developed. However, good management with clear job description should be applied to improve the business.

  7. 4E analysis and multi objective optimization of a micro gas turbine and solid oxide fuel cell hybrid combined heat and power system

    NASA Astrophysics Data System (ADS)

    Sanaye, Sepehr; Katebi, Arash

    2014-02-01

    Energy, exergy, economic and environmental (4E) analysis and optimization of a hybrid solid oxide fuel cell and micro gas turbine (SOFC-MGT) system for use as combined generation of heat and power (CHP) is investigated in this paper. The hybrid system is modeled and performance related results are validated using available data in literature. Then a multi-objective optimization approach based on genetic algorithm is incorporated. Eight system design parameters are selected for the optimization procedure. System exergy efficiency and total cost rate (including capital or investment cost, operational cost and penalty cost of environmental emissions) are the two objectives. The effects of fuel unit cost, capital investment and system power output on optimum design parameters are also investigated. It is observed that the most sensitive and important design parameter in the hybrid system is fuel cell current density which has a significant effect on the balance between system cost and efficiency. The selected design point from the Pareto distribution of optimization results indicates a total system exergy efficiency of 60.7%, with estimated electrical energy cost 0.057 kW-1 h-1, and payback period of about 6.3 years for the investment.

  8. Social Security reform: evaluating current proposals. Latest results of the EBRI-SSASIM2 policy simulation model.

    PubMed

    Copeland, C; VanDerhei, J; Salisbury, D L

    1999-06-01

    The present Social Security program has been shown to be financially unsustainable in the future without modification to the current program. The purpose of this Issue Brief, EBRI's fourth in a series on Social Security reform, is threefold: to illustrate new features of the EBRI-SSASIM2 policy simulation model not available in earlier EBRI publications, to expand quantitative analysis to specific proposals, and to evaluate the uncertainty involved in proposals that rely on equity investment. This analysis compares the Gregg/Breaux-Kolbe/Stenholm (GB-KS) and Moynihan/Kerrey proposals with three generic or "traditional" reforms: increasing taxes, reducing benefits, and/or increasing the retirement age. Both proposals would create individual accounts by "carving out" funds from current Social Security payroll taxes. This analysis also examines other proposed changes that would "add on" to existing Social Security funds through the use of general revenue transfers and/or investment in the equities market. President Clinton has proposed a general revenue transfer and the collective investment of some of the OASDI trust fund assets in equities. Reps. Archer and Shaw have proposed a general revenue tax credit to establish individual accounts that would be invested partially in the equities markets. When comparing Social Security reform proposals that would specifically alter benefit levels, the Moynihan/Kerrey bill compares quite favorably with the other proposals in both benefit levels and payback ratios, when individuals elect to use the individual account option. In contrast, the GB-KS bills do not compare quite as favorably for their benefit levels, but do compare favorably in terms of payback ratios. An important comparison in these bills is the administrative costs of managing the individual accounts, since benefits can be lowered by up to 23 percent when going from the assumed low to high administrative costs. Moreover, allowing individuals to decide whether to save the 2 percent of their OASDI taxable income or to receive higher takehome pay, as would be allowed in Moynihan/Kerrey, could lead to substantial differences in ultimate retirement income. Allowing for individual investment choices and using actual 401(k) participant allocation data, as opposed to an assumed average allocation for everyone, results in substantial differences in account balances. The Archer/Shaw approach mandates a 60 percent/40 percent equity/bond split specifically to avoid the variations in returns that arise from individual investment allocation decisions. Although there are greater chances for higher returns for equity investment in the president's proposal, there are also greater chances for worse outcomes. This is also true for other reforms that would invest Social Security assets in equities.

  9. A Case Study to Improve Emergency Room Patient Flow at Womack Army Medical Center

    DTIC Science & Technology

    2009-06-01

    use just the previous month, moving average 2-month period ( MA2 ) uses the average from the previous two months, moving average 3-month period (MA3...ED prior to discharge by provider) MA2 /MA3/MA4 - moving averages of 2-4 months in length MAD - mean absolute deviation (measure of accuracy for

  10. Response of soil respiration to climate across biofuel crops and land use histories

    NASA Astrophysics Data System (ADS)

    Su, Y.; Chen, J.; Shao, C.; Shen, W.; Zenone, T.; John, R.; Deal, M.; Hamilton, S. K.; Robertson, G. P.

    2013-12-01

    Land use change (LUC) due to the worldwide increasing production of biofuel crops creates carbon debt that would require decades to repay. The payback time depends on the net ecosystem exchange (NEE) of CO2 and more determined by the carbon loss, such as soil respiration, than photosynthesis offset. Soil respiration is not only an important part of ecosystem respiration, but is also highly correlated with ecosystem production, via substrate subsidies from plants. Both autotrophic and heterotrophic soil respiration were regulated by climated-induced factors (e.g. soil temperature and soil water content) and also affected by substrate supply. In 2009, three sites in conservation reserve program (CRP) and conventional corn-soybean rotation agricultural lands (AG), were converted to soybean production, in experimental sites at Kellogg Biological Station, MI. In 2010, the three sites of differential previous land uses were then converted to corn (Cr), switchgrass (Sw) and prairie mixture (Pr) production. A reference site has been maintained CRP status since then. We used chamber-based method to assess total and heterotrophic soil respirations rate (SRRt and SRRh) from control treatment (C) and root exclusion treatment (E) at all sites, in 2011 and 2012, to explore how soil respiration rate (SRR) respond to the change of abiotic and biotic factors. Our results show that soil temperature (Ts) are important factors that affect SRR patterns. At the beginning of growing season, SRRs are low (average SRRt and SRRh are 3.19 and 3.11 umol CO2/m2s, respectively, on April 10th, 2011) when soil temperature is low. SRRs in general increased over time in a year, peaked in late July- early August, 1-2 weeks after soil temperature arrive its peak (maximum average SRRt and SRRh are 8.64 and 5.68, respectively, on August 3rd/4th, 2011). Soil water content (VWC) did not affect the time of SRR peak but limited its amount; when VWCs were extremely low in 2012 (average VWC at C and E treatment decreased 2.25% and 8.55%, respectively, in mid-summer between 2011 and 2012), SRRs were also comparatively low (average SRRt and SRRh decreased 5.57 and 3.12 umol CO2/m2s, respectively, in 2012). Besides, substrate supply importantly regulates SRRs; the patterns of SRR coincide that of crop growth through a growing season. SRRs of annual plan (corn) sites have very narrow peaks while SRRs of perennial crops (all of the rest crops in the experiment) have extended periods of highest SRRs. This may be a consequence of the difference between the phenology of annual and perennial crops. Generally, SRRh are lower than SRRt at all AG and reference sites (the difference between SRRh and SRRt are 5.23, 2.32, 3.87 and 6.03 at AG-Cr, AG-Sw, AG-Pr and reference site, respectively) in mid-summer in 2011, however, the difference between SRRh and SRRt are close at CRP sites (the difference are 1.42, 1.87 and -0.07 at CRP-Cr, CRP-Sw and CRP-Pr site). Large amount of carbon released into soil due to land use change at CRP sites would lead to high SRRh.

  11. Design and construction evaluation of a photovoltaic DC LED lighting system

    NASA Astrophysics Data System (ADS)

    Bhamidipati, Jyotsna

    2008-08-01

    The market demand for commercialization of Photovoltaic (PV) systems depends a lot on the reliability, efficiency and performance of various components within the system. PV panels produce DC power when exposed to sunlight, and an inverter converts this to AC power in a typical solar powered building. Though, PV lighting has existed for a long time it hasn't been very effective, as incandescent light sources were commonly used which are inefficient. Today fluorescent fixtures are mostly used with PV's due to its high efficacy. Light-emitting diodes present a new vision to energy efficiency in lighting design with their low energy consumption. Current research predicts improved efficiencies of LED light fixtures and their commercial use is a few years away. LEDs which operate on DC voltages when coupled with photovoltaics can be a simple PV lighting application and a sustainable solution with potential for payback. This research evaluates the design and construction of a photovoltaic DC LED lighting system for a solar house at Pennsylvania State University. A detailed cost and payback analysis of a PV DC LED lighting system is presented in this research. PV output simulations for the solar house are presented. Results presented in this research indicate that the Solid state lighting market is evolving rapidly and that LED's are a choice in stand-alone photovoltaic DC lighting systems. The efficiency and the cost-effectiveness of such systems would however improve in the coming years with research and development now focused on PV systems and on Solid state lighting technologies.

  12. Cost effectiveness of converting to alternative motor vehicle fuels. A technical assistance study for the City of Longview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCoy, G.A.

    1983-11-18

    The City of Longview can obtain significant fuel savings benefits by converting a portion of their vehicle fleet to operate on either compressed natural gas (CNG) or liquid petroleum gas (LPG) fuels. The conversion of 41 vehicles including police units, sedans, pickups, and light duty trucks to CNG use would offset approximately 47% of the city's 1982 gasoline consumption. The CNG conversion capital outlay of $115,000 would be recovered through fuel cost reductions. The Cascade Natural Gas Corporation sells natural gas under an interruptible tariff for $0.505 per therm, equivalent to slightly less than one gallon of gasoline. The citymore » currently purchases unleaded gasoline at $1.115 per gallon. A payback analysis indicates that 39.6 months are required for the CNG fuel savings benefits to offset the initial or first costs of the conversion. The conversion of fleet vehicles to liquid petroleum gas (LPG) or propane produces comparable savings in vehicle operating costs. The conversion of 59 vehicles including police units, pickup and one ton trucks, street sweepers, and five cubic yard dump trucks would cost approximately $59,900. The annual purchase of 107,000 gallons of propane would offset the consumption of 96,300 gallons of gasoline, or approximately 67% of the city's 1982 usage. Propane is currently retailing for $0.68 to $0.74 per gallon. A payback analysis indicates that 27.7 months are required for the fuel savings benefits to offset the initial LPG conversion costs.« less

  13. Net energy payback and CO2 emissions from three midwestern wind farms: An update

    USGS Publications Warehouse

    White, S.W.

    2006-01-01

    This paper updates a life-cycle net energy analysis and carbon dioxide emissions analysis of three Midwestern utility-scale wind systems. Both the Energy Payback Ratio (EPR) and CO2 analysis results provide useful data for policy discussions regarding an efficient and low-carbon energy mix. The EPR is the amount of electrical energy produced for the lifetime of the power plant divided by the total amount of energy required to procure and transport the materials, build, operate, and decommission the power plants. The CO2 analysis for each power plant was calculated from the life-cycle energy input data. A previous study also analyzed coal and nuclear fission power plants. At the time of that study, two of the three wind systems had less than a full year of generation data to project the life-cycle energy production. This study updates the analysis of three wind systems with an additional four to eight years of operating data. The EPR for the utility-scale wind systems ranges from a low of 11 for a two-turbine system in Wisconsin to 28 for a 143-turbine system in southwestern Minnesota. The EPR is 11 for coal, 25 for fission with gas centrifuge enriched uranium and 7 for gaseous diffusion enriched uranium. The normalized CO2 emissions, in tonnes of CO2 per GW eh, ranges from 14 to 33 for the wind systems, 974 for coal, and 10 and 34 for nuclear fission using gas centrifuge and gaseous diffusion enriched uranium, respectively. ?? Springer Science+Business Media, LLC 2007.

  14. The Relationship Between Structural Game Characteristics and Gambling Behavior: A Population-Level Study.

    PubMed

    Leino, Tony; Torsheim, Torbjørn; Blaszczynski, Alex; Griffiths, Mark; Mentzoni, Rune; Pallesen, Ståle; Molde, Helge

    2015-12-01

    The aim of this study was to examine the relationship between the structural characteristics and gambling behavior among video lottery terminal (VLT) gamblers. The study was ecological valid, because the data consisted of actual gambling behavior registered in the participants natural gambling environment without intrusion by researchers. Online behavioral tracking data from Multix, an eight game video lottery terminal, were supplied by Norsk-Tipping (the state owned gambling company in Norway). The sample comprised the entire population of Multix gamblers (N = 31,109) who had gambled in January 2010. The individual number of bets made across games was defined as the dependent variable, reward characteristics of a game (i.e., payback percentage, hit frequency, size of winnings and size of jackpot) and bet characteristics of a game (i.e., range of betting options and availability of advanced betting options) served as the independent variables. Control variables were age and gender. Two separate cross-classified multilevel random intercepts models were used to analyze the relationship between bets made, reward characteristics and bet characteristics, where the number of bets was nested within both individuals and within games. The results show that the number of bets is positively associated with payback percentage, hit frequency, being female and age, and negatively associated with size of wins and range of available betting options. In summary, the results show that the reward characteristics and betting options explained 27% and 15% of the variance in the number of bets made, respectively. It is concluded that structural game characteristics affect gambling behavior. Implications of responsible gambling are discussed.

  15. Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widder, Sarah H.; Parker, Graham B.; Baechler, Michael C.

    2012-08-01

    To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures ofmore » each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.« less

  16. 7 CFR 1940.302 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... flood—A flood of a magnitude that occurs once every 100 years on the average. Within any one-year period... a magnitude that occurs once every 500 years on the average. (Within any one-year period there is... that occurs once every 100 years on the average (the flood having a one-percent chance of being...

  17. 7 CFR 1940.302 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... flood—A flood of a magnitude that occurs once every 100 years on the average. Within any one-year period... a magnitude that occurs once every 500 years on the average. (Within any one-year period there is... that occurs once every 100 years on the average (the flood having a one-percent chance of being...

  18. 40 CFR 133.101 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... arithmetic mean of pollutant parameter values for samples collected in a period of 7 consecutive days. (b) 30-day average. The arithmetic mean of pollutant parameter values of samples collected in a period of 30... percentile value for the 30-day average effluent quality achieved by a treatment works in a period of at...

  19. RHIC BPM system average orbit calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff,R.; Cerniglia, P.; Degen, C.

    2009-05-04

    RHIC beam position monitor (BPM) system average orbit was originally calculated by averaging positions of 10000 consecutive turns for a single selected bunch. Known perturbations in RHIC particle trajectories, with multiple frequencies around 10 Hz, contribute to observed average orbit fluctuations. In 2006, the number of turns for average orbit calculations was made programmable; this was used to explore averaging over single periods near 10 Hz. Although this has provided an average orbit signal quality improvement, an average over many periods would further improve the accuracy of the measured closed orbit. A new continuous average orbit calculation was developed justmore » prior to the 2009 RHIC run and was made operational in March 2009. This paper discusses the new algorithm and performance with beam.« less

  20. Solar energy for electricity and fuels.

    PubMed

    Inganäs, Olle; Sundström, Villy

    2016-01-01

    Solar energy conversion into electricity by photovoltaic modules is now a mature technology. We discuss the need for materials and device developments using conventional silicon and other materials, pointing to the need to use scalable materials and to reduce the energy payback time. Storage of solar energy can be achieved using the energy of light to produce a fuel. We discuss how this can be achieved in a direct process mimicking the photosynthetic processes, using synthetic organic, inorganic, or hybrid materials for light collection and catalysis. We also briefly discuss challenges and needs for large-scale implementation of direct solar fuel technologies.

  1. Present capabilities and future requirements for computer-aided geometric modeling in the design and manufacture of gas turbine

    NASA Technical Reports Server (NTRS)

    Caille, E.; Propen, M.; Hoffman, A.

    1984-01-01

    Gas turbine engine design requires the ability to rapidly develop complex structures which are subject to severe thermal and mechanical operating loads. As in all facets of the aerospace industry, engine designs are constantly driving towards increased performance, higher temperatures, higher speeds, and lower weight. The ability to address such requirements in a relatively short time frame has resulted in a major thrust towards integrated design/analysis/manufacturing systems. These computer driven graphics systems represent a unique challenge, with major payback opportunities if properly conceived, implemented, and applied.

  2. Naftokrak-Naftdbudowa & MPEC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szewczyk, T.; Mazur, J.

    1995-12-31

    Polish graded coal is being burned on existing stoker boilers at MPEC`s Balicka plant, using Control Techtronics microprocess-based system. Pictures were shown of the equipment controlling three hot water WR-10 boilers, and (two) steam 22.5 boilers. The results of this installation include; 85% reduction in stack particulate emission, 25% increase in boiler energy efficiency, 65% reduction in fan electrical energy, achieving {open_quotes}ultra low fire{close_quotes} which provides 3 or 4 to 1 turndown, versus 2 to 1, for substantially reduced fuel use at low heating requirements, and 2 to 3 years payback on invested capital.

  3. Managing loss adjustment expenses: strategies for health care risk managers.

    PubMed

    Quinley, K M

    1991-01-01

    Like most businesses, adjusting companies are not charitable organizations. They are entitled to a reasonable profit, which the risk manager should not begrudge. As a buyer of adjusting services, a risk manager with an inordinate obsession with slashing adjusting bills can destroy the goal of high-quality service. It is best for risk managers to pick and choose the areas for cutting adjusting expenses. To an extent, health care risk managers should view payment of high-quality adjusting services as an investment, with the payback being money saved by fighting fraudulent, exaggerated, and questionable claims.

  4. Analysis of the economics of typical business applications of solar energy

    NASA Astrophysics Data System (ADS)

    1981-11-01

    An economic analysis is provided of flat plate collector systems in industrial, commercial, and agricultural business applications in a variety of locations. A key element of the analysis is the federal solar investment tax credit. The SOLCOST Solar Energy Design Program is used for the study. The differences between industrial agricultural and commercial applications are considered, as are finance and tax data and fuel data. The rate of return and payback are the criteria used to compare the economic viability of systems. Market penetration estimates for process steam were derived for seven southwestern states where direct solar radiation is highest.

  5. Processes and energy costs for mining lunar Helium-3

    NASA Technical Reports Server (NTRS)

    Sviatoslavsky, I. N.

    1988-01-01

    Preliminary investigations show that obtaining He-3 from the moon is technically feasible and economically viable. With the exception of beneficiation, the proposed procedures are state of the art. Mass of equipment needed from earth is of some concern, but resupply will eventually be ameliorated by the use of titanium from indigenous ilmenite. A complete energy payback from a D/He-3 fusion reactor utilizing lunar He-3 is approx. 80, providing ample incentive for commercial investment is forthcoming. Byproducts will be of great value to the resupply of a permanent lunar base and enhancement of space exploration.

  6. Refrigerated Warehouse Demand Response Strategy Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Doug; Castillo, Rafael; Larson, Kyle

    This guide summarizes demand response measures that can be implemented in refrigerated warehouses. In an appendix, it also addresses related energy efficiency opportunities. Reducing overall grid demand during peak periods and energy consumption has benefits for facility operators, grid operators, utility companies, and society. State wide demand response potential for the refrigerated warehouse sector in California is estimated to be over 22.1 Megawatts. Two categories of demand response strategies are described in this guide: load shifting and load shedding. Load shifting can be accomplished via pre-cooling, capacity limiting, and battery charger load management. Load shedding can be achieved by lightingmore » reduction, demand defrost and defrost termination, infiltration reduction, and shutting down miscellaneous equipment. Estimation of the costs and benefits of demand response participation yields simple payback periods of 2-4 years. To improve demand response performance, it’s suggested to install air curtains and another form of infiltration barrier, such as a rollup door, for the passageways. Further modifications to increase efficiency of the refrigeration unit are also analyzed. A larger condenser can maintain the minimum saturated condensing temperature (SCT) for more hours of the day. Lowering the SCT reduces the compressor lift, which results in an overall increase in refrigeration system capacity and energy efficiency. Another way of saving energy in refrigerated warehouses is eliminating the use of under-floor resistance heaters. A more energy efficient alternative to resistance heaters is to utilize the heat that is being rejected from the condenser through a heat exchanger. These energy efficiency measures improve efficiency either by reducing the required electric energy input for the refrigeration system, by helping to curtail the refrigeration load on the system, or by reducing both the load and required energy input.« less

  7. [Estimation of the asymptomatic latent period of alveolar hydatidosis in patients infected in foreign endemic areas].

    PubMed

    Doi, Rikuo

    2007-03-01

    Alveolar hydatidosis (AH) is a parasitic disease with an extremely long latent period which has an important role in the endemic of human AH. The individual and average latent periods of human AH were estimated from the case histories of 19 male patients who were infected in foreign endemic areas and diagnosed surgically and pathologically as having AH after returning to Honshu, mainland of Japan. The beginning (A) and the end (C) of stay in foreign endemic areas of AH, and the midpoint (B) between (A) and (C), the time of onset of symptoms (D) and death (E) of AH were determined in the case reports. The period (D-B) from the midpoint (B) to the onset of symptoms (D) was considered as an individual latent period of AH, and the average latent period was estimated from D-B periods. The individual latent periods ranged from 3 to 44 years, and the average was 20 +/- 10 (mean +/- SD) years in the 19 cases. The average latent period was longer in 7 surviving cases (26 +/- 12) than in 12 fatal cases (16 +/- 7) at the publication of the case reports, but there was no statistically significant difference between them. The estimated latent period in this report was very close to that by Doi et al. (2000), and the traditional 5-15 years should be changed to 7-35 years.

  8. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Conlin, Francis; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  9. Air Distribution Retrofit Strategies for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, J.; Conlin, F.; Holloway, Parker

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  10. 20 CFR 10.216 - How is the pay rate for COP calculated?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... for COP purposes is equal to the employee's regular “weekly” pay (the average of the weekly pay over... period of appointment), the weekly pay rate is an average of the weekly earnings, established by dividing... or every week of the year (or period of appointment), the weekly pay rate is the average weekly...

  11. Sources of suspended sediment in the Waikele watershed, Oʻahu, Hawaiʻi

    USGS Publications Warehouse

    Izuka, Scot K.

    2012-01-01

    Data from streamflow/sediment gages and measurements of changes in channel-bed sediment storage were gathered between October 1, 2007, and September 30, 2010, to assess the sources of suspended sediment in the Waikele watershed, Oʻahu, Hawaiʻi. Streamflow from the watershed averaged 33 cubic feet per second during the study period, with interannual variations corresponding with variations in the frequency and magnitude of storm-flow peaks. Average streamflow during the study period was lower than the long-term average, but the study period included a storm on December 11, 2008, that caused record-high streamflows in parts of the watershed. Suspended-sediment yield from the Waikele watershed during the study period averaged 82,500 tons per year, which is 2.7 times higher than the long-term average. More than 90 percent of the yield during the study period was discharged during the December 11, 2008, storm. The study-period results are consistent with long-term records that show that the vast majority of suspended-sediment transport occurs during a few large storms. Results of this study also show that all but a small percentage of the suspended-sediment yield came from hillslopes. Only a small fraction of bed sediments is fine enough to be transported as suspended load; most bed sediments in the watershed are coarse. Silt and clay constitute less than 3 percent of the bed-sediment volume on average. Some larger clasts, however, can disintegrate during transport and contribute to the suspended load downstream. During the study period, suspended-sediment yield from the urbanized Mililani subbasin averaged 25 tons per year per square mile (tons/yr/mi2), which was much smaller than the yield from any other subbasin; these results indicate that urban land use yields much less sediment than other land uses. The wet, forested Kipapa subbasin had an average normalized hillslope suspended-sediment yield of 386 tons/yr/mi2; the average yield for forested areas in the watershed may be lower. Suspended-sediment yield from agricultural land use in the watershed is estimated to range between 5,590 and 6,440 tons/yr/mi2 during the study period; the long-term average is estimated to be 2,070 to 2,390 tons/yr/mi2. Of the three land uses considered, agriculture had by far the highest normalized suspended-sediment yield during this study - about an order of magnitude higher than forests and two orders of magnitude higher than urban areas.

  12. 40 CFR 80.101 - Standards applicable to refiners and importers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... are produced or imported over a period no longer than one month; (iii) Uses the total of the volumes... Administrator may grant an averaging period of two, three, four or five years upon petition of a refiner who: (A... for a two or three year averaging period must be submitted by June 1, 2003. Regardless of the...

  13. 40 CFR 80.101 - Standards applicable to refiners and importers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... are produced or imported over a period no longer than one month; (iii) Uses the total of the volumes... Administrator may grant an averaging period of two, three, four or five years upon petition of a refiner who: (A... for a two or three year averaging period must be submitted by June 1, 2003. Regardless of the...

  14. 40 CFR 80.101 - Standards applicable to refiners and importers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... are produced or imported over a period no longer than one month; (iii) Uses the total of the volumes... Administrator may grant an averaging period of two, three, four or five years upon petition of a refiner who: (A... for a two or three year averaging period must be submitted by June 1, 2003. Regardless of the...

  15. Effects of Agricultural Land-Use Changes and Rainfall on Ground-Water Recharge in Central and West Maui, Hawai`i, 1926-2004

    USGS Publications Warehouse

    Engott, John A.; Vana, Thomas T.

    2007-01-01

    Concern surrounding declines in ground-water levels and an increase in the chloride concentration of water pumped from wells in the Iao aquifer system on the Island of Maui has prompted an investigation into the long-term sustainability of current (2006) and future ground-water withdrawals. As part of this investigation, a water budget for central and west Maui was calculated from which (1) ground-water recharge was estimated for the period 1926-2004 and (2) the effects of agricultural land-use changes and drought were analyzed. Estimated mean ground-water recharge decreased 44 percent from 1979 to 2004 in central and west Maui. Reduction in agricultural irrigation, resulting from more efficient irrigation methods and a reduction in the acreage used for agriculture, is largely responsible for the declining recharge. Recently, periods of lower-than-average rainfall have further reduced recharge. During the period 1926-79, ground-water recharge averaged 693 Mgal/d, irrigation averaged 437 Mgal/d, and rainfall averaged 897 Mgal/d. During the period 2000-04, ground-water recharge averaged 391 Mgal/d, irrigation averaged 237 Mgal/d, and rainfall averaged 796 Mgal/d. Simulations of hypothetical future conditions indicate that a cessation of agriculture in central and west Maui would reduce mean ground-water recharge by 18 percent in comparison with current conditions, assuming that current climatic conditions are the same as the long-term-average conditions during the period 1926-2004. A period of drought identical to that of 1998-2002 would reduce mean recharge by 27 percent. Mean recharge would decrease by 46 percent if this drought were to occur after a cessation of agriculture in central and western Maui. Whereas droughts are transient phenomena, a reduction in agricultural irrigation is likely a permanent condition.

  16. The effect of long working hours on cerebrovascular and cardiovascular disease; A case-crossover study.

    PubMed

    Shin, Kyong-Sok; Chung, Yun Kyung; Kwon, Young-Jun; Son, Jun-Seok; Lee, Se-Hoon

    2017-09-01

    This study investigated the relationship between weekly working hours and the occurrence of cerebro-cardiovascular diseases using a case-crossover study design. We investigated average working hours during the 7 days before the onset of illness (hazard period) and average weekly working hours between 8 days and 3 months before the onset of cerebro-cardiovascular diseases (control period) for 1,042 cases from the workers' compensation database for 2009. Among all subjects, the odds ratio by conditional logistic regression for the risk of cerebro-cardiovascular diseases with a 10 hr increase in average weekly working hours was 1.45 (95% confidence interval [CI]: 1.22-1.72), a significant association. An increase in average weekly working hours may trigger the onset of cerebro-cardiovascular disease. Am. J. Ind. Med. 60:753-761, 2017. © 2017. Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. LCA as a Tool to Evaluate Green Infrastructure's Environmental Performance

    NASA Astrophysics Data System (ADS)

    Catalano De Sousa, M.; Erispaha, A.; Spatari, S.; Montalto, F.

    2011-12-01

    Decentralized approaches to managing urban stormwater through use of green infrastructure (GI) often lead to system-wide efficiency gains within the urban watershed's energy supply system. These efficiencies lead to direct greenhouse gas (GHG) emissions savings, and also restore some ecosystem functions within the urban landscape. We developed a consequential life cycle assessment (LCA) model to estimate the life cycle energy, global warming potential (GWP), and payback times for each if GI were applied within a select neighborhood in New York City. We applied the SIMAPRO LCA software and the economic input-output LCA (EIO-LCA) tool developed by Carnegie Mellon University. The results showed that for a new intersection installation highlighted in this study a conventional infrastructure construction would emit and use approximately 3 times more for both CO2 and energy than a design using GI. Two GI benefits were analyzed with regards to retrofitting the existing intersection. The first was related to the savings in energy and CO2 at the Waste Water Treatment Plant via runoff reduction accrued from GI use. The second benefit was related to the avoided environmental costs associated with an additional new grey infrastructure installation needed to prevent CSO in case of no GI implementation. The first benefit indicated a high payback time for a GI installation in terms of CO2 and energy demand (80 and 90 years respectively) and suggest a slow energy and carbon recovery time. However, concerning to the second benefit, GI proved to be a sustainable alternative considering the high CO2 releases (429 MTE) and energy demand (5.5 TJ) associated with a grey infrastructure construction.

  18. Spatially-explicit estimates of greenhouse-gas payback times for perennial cellulosic biomass production on open lands in the Lake States

    NASA Astrophysics Data System (ADS)

    Sahajpal, R.

    2015-12-01

    The development of renewable energy sources is an integral step towards mitigating the carbon dioxide induced component of climate change. One important renewable source is plant biomass, comprising both food crops such as corn (Zea mays) and cellulosic biomass from short-rotation woody crops (SRWC) such as hybrid-poplar (Populus spp.) and Willow (Salix spp.). Due to their market acceptability and excellent energy balance, cellulosic feedstocks represent an abundant and if managed properly, a carbon-neutral and environmentally beneficial resource. We evaluate how site variability impacts the greenhouse-gas (GHG) benefits of SRWC plantations on lands potentially suited for bioenergy feedstock production in the Lake States (Minnesota, Wisconsin, Michigan). We combine high-resolution, spatially-explicit estimates of biomass, soil organic carbon and nitrous oxide emissions for SRWC plantations from the Environmental Policy Integrated Climate (EPIC) model along with life cycle analysis results from the GREET model to determine the greenhouse-gas payback time (GPBT) or the time needed before the GHG savings due to displacement of fossil fuels exceeds the initial losses from plantation establishment. We calibrate our models using unique yield and N2O emission data from sites across the Lake states that have been converted from pasture and hayfields to SRWC plantations. Our results show a reduction of 800,000 ha in non-agricultural open land availability for biomass production, a loss of nearly 37% (see attached figure). Overall, GPBTs range between 1 and 38 years, with the longest GPBTs occurring in the northern Lake states. Initial soil nitrate levels and site drainage potential explain more than half of the variation in GPBTs. Our results indicate a rapidly closing window of opportunity to establish a sustainable cellulosic feedstock economy in the Lake States.

  19. A Practical Application of Value of Information and Prospective Payback of Research to Prioritize Evaluative Research.

    PubMed

    Andronis, Lazaros; Billingham, Lucinda J; Bryan, Stirling; James, Nicholas D; Barton, Pelham M

    2016-04-01

    Efforts to ensure that funded research represents "value for money" have led to increasing calls for the use of analytic methods in research prioritization. A number of analytic approaches have been proposed to assist research funding decisions, the most prominent of which are value of information (VOI) and prospective payback of research (PPoR). Despite the increasing interest in the topic, there are insufficient VOI and PPoR applications on the same case study to contrast their methods and compare their outcomes. We undertook VOI and PPoR analyses to determine the value of conducting 2 proposed research programs. The application served as a vehicle for identifying differences and similarities between the methods, provided insight into the assumptions and practical requirements of undertaking prospective analyses for research prioritization, and highlighted areas for future research. VOI and PPoR were applied to case studies representing proposals for clinical trials in advanced non-small-cell lung cancer and prostate cancer. Decision models were built to synthesize the evidence available prior to the funding decision. VOI (expected value of perfect and sample information) and PPoR (PATHS model) analyses were undertaken using the developed models. VOI and PPoR results agreed in direction, suggesting that the proposed trials would be cost-effective investments. However, results differed in magnitude, largely due to the way each method conceptualizes the possible outcomes of further research and the implementation of research results in practice. Compared with VOI, PPoR is less complex but requires more assumptions. Although the approaches are not free from limitations, they can provide useful input for research funding decisions. © The Author(s) 2015.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frischknecht, Rolf; Heath, Garvin; Raugei, Marco

    Life Cycle Assessment (LCA) is a structured, comprehensive method of quantifying material- and energy-flows and their associated emissions caused in the life cycle of goods and services. The ISO 14040 and 14044 standards provide the framework for LCA. However, this framework leaves the individual practitioner with a range of choices that can affect the results and thus the conclusions of an LCA study. The current IEA guidelines were developed to provide guidance on assuring consistency, balance, and quality to enhance the credibility and reliability of the results from LCAs on photovoltaic (PV) electricity generation systems. The guidelines represent a consensusmore » among the authors - PV LCA experts in North America, Europe, and Asia - for assumptions made on PV performance, decisions on process input and emissions allocation, methods of analysis, and reporting of the results. Guidance is given on PV-specific parameters used as inputs in LCA and on choices and assumptions in life cycle inventory (LCI) data analysis and on implementation of modeling approaches. A consistent approach towards system modeling, the functional unit, the system boundaries, water use modeling and the allocation aspects enhances the credibility of PV electricity LCA studies and enables balanced LCA-based comparisons of different electricity producing technologies. The document discusses metrics like greenhouse gas emissions (GHG), cumulative energy demand (CED), acidification potential (AP), ozone depletion potential (ODP), human toxicity, ecotoxicity and ionizing radiation. Guidance is given for the definition of the energy payback time (EPBT), the nonrenewable energy payback time (NREPBT), and the impact mitigation potentials (IMP). The indicator energy return on investment (EROI) is described in a separate International Energy Agency (IEA) PV Power Systems (PVPS) Task 12 report (Raugei et al. 2015). The guidelines on the reporting and communication of the results serve the need for producing clear, comprehensive and transparent reports.« less

  1. Low-flow analysis and selected flow statistics representative of 1930-2002 for streamflow-gaging stations in or near West Virginia

    USGS Publications Warehouse

    Wiley, Jeffrey B.

    2006-01-01

    Five time periods between 1930 and 2002 are identified as having distinct patterns of annual minimum daily mean flows (minimum flows). Average minimum flows increased around 1970 at many streamflow-gaging stations in West Virginia. Before 1930, however, there might have been a period of minimum flows greater than any period identified between 1930 and 2002. The effects of climate variability are probably the principal causes of the differences among the five time periods. Comparisons of selected streamflow statistics are made between values computed for the five identified time periods and values computed for the 1930-2002 interval for 15 streamflow-gaging stations. The average difference between statistics computed for the five time periods and the 1930-2002 interval decreases with increasing magnitude of the low-flow statistic. The greatest individual-station absolute difference was 582.5 percent greater for the 7-day 10-year low flow computed for 1970-1979 compared to the value computed for 1930-2002. The hydrologically based low flows indicate approximately equal or smaller absolute differences than biologically based low flows. The average 1-day 3-year biologically based low flow (1B3) and 4-day 3-year biologically based low flow (4B3) are less than the average 1-day 10-year hydrologically based low flow (1Q10) and 7-day 10-year hydrologic-based low flow (7Q10) respectively, and range between 28.5 percent less and 13.6 percent greater. Seasonally, the average difference between low-flow statistics computed for the five time periods and 1930-2002 is not consistent between magnitudes of low-flow statistics, and the greatest difference is for the summer (July 1-September 30) and fall (October 1-December 31) for the same time period as the greatest difference determined in the annual analysis. The greatest average difference between 1B3 and 4B3 compared to 1Q10 and 7Q10, respectively, is in the spring (April 1-June 30), ranging between 11.6 and 102.3 percent greater. Statistics computed for the individual station's record period may not represent the statistics computed for the period 1930 to 2002 because (1) station records are available predominantly after about 1970 when minimum flows were greater than the average between 1930 and 2002 and (2) some short-term station records are mostly during dry periods, whereas others are mostly during wet periods. A criterion-based sampling of the individual station's record periods at stations was taken to reduce the effects of statistics computed for the entire record periods not representing the statistics computed for 1930-2002. The criterion used to sample the entire record periods is based on a comparison between the regional minimum flows and the minimum flows at the stations. Criterion-based sampling of the available record periods was superior to record-extension techniques for this study because more stations were selected and areal distribution of stations was more widespread. Principal component and correlation analyses of the minimum flows at 20 stations in or near West Virginia identify three regions of the State encompassing stations with similar patterns of minimum flows: the Lower Appalachian Plateaus, the Upper Appalachian Plateaus, and the Eastern Panhandle. All record periods of 10 years or greater between 1930 and 2002 where the average of the regional minimum flows are nearly equal to the average for 1930-2002 are determined as representative of 1930-2002. Selected statistics are presented for the longest representative record period that matches the record period for 77 stations in West Virginia and 40 stations near West Virginia. These statistics can be used to develop equations for estimating flow in ungaged stream locations.

  2. Evaluation of effects of groundwater withdrawals at the proposed Allen combined-cycle combustion turbine plant, Shelby County, Tennessee

    USGS Publications Warehouse

    Haugh, Connor J.

    2016-08-10

    The Mississippi Embayment Regional Aquifer Study groundwater-flow model was used to simulate the potential effects of future groundwater withdrawals at the proposed Allen combined-cycle combustion turbine plant in Shelby County, Tennessee. The scenario used in the simulation consisted of a 30-year average withdrawal period followed by a 30-day maximum withdrawal period. Effects of withdrawals at the Allen plant site on the Mississippi embayment aquifer system were evaluated by comparing the difference in simulated water levels in the aquifers at the end of the 30-year average withdrawal period and at the end of the scenario to a base case without the Allen combined-cycle combustion turbine plant withdrawals. Simulated potentiometric surface declines in the Memphis aquifer at the Allen plant site were about 7 feet at the end of the 30-year average withdrawal period and 11 feet at the end of the scenario. The affected area of the Memphis aquifer at the Allen plant site as delineated by the 4-foot potentiometric surface-decline contour was 2,590 acres at the end of the 30-year average withdrawal period and 11,380 acres at the end of the scenario. Simulated declines in the underlying Fort Pillow aquifer and overlying shallow aquifer were both less than 1 foot at the end of the 30-year average withdrawal period and the end of the scenario.

  3. Demonstration Assessment of Light Emitting Diode (LED) Commercial Garage Lights In the Providence Portland Medical Center, Portland, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ton, My K.; Richman, Eric E.; Gilbride, Theresa L.

    2008-11-11

    This U.S. Department of Energy GATEWAY Demonstration project studied the applicability of light-emitting diode (LED) luminaires for commercial parking garage applications. High-pressure sodium (HPS) area luminaires were replaced with new LED area luminaires. The project was supported under the U.S. Department of Energy (DOE) Solid State Lighting Program. Other participants in the demonstration project included Providence Portland Medical Center in Portland, Oregon, the Energy Trust of Oregon, and Lighting Sciences Group (LSG) Inc. Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. PNNL manages GATEWAY demonstrations for DOE and represents their perspective in the conduct ofmore » the work. Quantitative and qualitative measurements of light and electrical power were taken at the site for both HPS and LED light sources. Economic costs were estimated and garage users’ responses to the new light sources were gauged with a survey. Six LED luminaires were installed in the below-ground parking level A, replacing six existing 150W HPS lamps spread out over two rows of parking spaces. Illuminance measurements were taken at floor level approximately every 4 ft on a 60-ft x 40-ft grid to measure light output of these LED luminaires which were termed the “Version 1” luminaires. PNNL conducted power measurements of the circuit in the garage to which the 6 luminaires were connected and determined that they drew an average of 82 W per lamp. An improved LED luminaire, Version 2, was installed in Level B of the parking garage. Illuminance measurements were not made of this second luminaire on site due to higher traffic conditions, but photometric measurements of this lamp and Version 1 were made in an independent testing laboratory and power usage for Version 2 was also measured. Version 1 was found to produce 3600 lumens and Version 2 was found to produce 4700 lumens of light and to consume 78 Watts. Maximum and minimum light levels were measured for the HPS and LED Version 1 luminaires and projected for the Version 2 luminaires. Maximum light levels were 23.51 foot candles, 20.54 fc, and 26.7 fc respectively and minimum light levels were 1.49 fc, 1.45 fc, and 1.88 fc. These results indicate very similar or even slightly higher light levels produced by the LED lamps, despite the higher lumen output of the HPS lamp. The LED lamps provide higher luminaire efficacy because all of the light is directed down and out. None of it is “lost” in the fixture. Also the HPS luminaire had poorly designed optics and a plastic covering that tended to get dirty and cracked, further decreasing the realized light output.[is this an accurate way to say this?] Consumer perceptions of the Version 2 LED were collected via a written survey form given to maintenance and security personnel. More than half felt the LED luminaires provided more light than the HPS lamps and a majority expressed a preference for the new lamps when viewing the relamped area through a security camera. Respondents commented that the LED luminaires were less glary, created less shadows, had a positive impact on visibility, and improved the overall appearance of the area. PNNL conducted an economic analysis and found that the Version 1 lamp produced annual energy savings of 955 kWh and energy cost savings of $76.39 per lamp at electricity rates of 6.5 cents per kWh and $105.03 at 11 cents per kWh. PNNL found that the Version 2 lamp produced annual energy savings of 991 kWh and energy cost savings of $79.26 per lamp at electricity rates of 6.5 cents per kWh and $108.98 at 11 cents per kWh. PNNL also calculated simple payback and found that Version 1 showed paybacks of 5.4 yrs at 6.5c/kWh and 4.1 yrs at 11c/kWh while Version 2 showed paybacks of 5.2 yrs at 6.5c/kWh and 3.9 yrs at 11c/kWh.« less

  4. The need for higher-order averaging in the stability analysis of hovering, flapping-wing flight.

    PubMed

    Taha, Haithem E; Tahmasian, Sevak; Woolsey, Craig A; Nayfeh, Ali H; Hajj, Muhammad R

    2015-01-05

    Because of the relatively high flapping frequency associated with hovering insects and flapping wing micro-air vehicles (FWMAVs), dynamic stability analysis typically involves direct averaging of the time-periodic dynamics over a flapping cycle. However, direct application of the averaging theorem may lead to false conclusions about the dynamics and stability of hovering insects and FWMAVs. Higher-order averaging techniques may be needed to understand the dynamics of flapping wing flight and to analyze its stability. We use second-order averaging to analyze the hovering dynamics of five insects in response to high-amplitude, high-frequency, periodic wing motion. We discuss the applicability of direct averaging versus second-order averaging for these insects.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Ansanelli, Eric; Henderson, Hugh

    Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperaturemore » modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.« less

  6. Feasibility study for retrofitting biogas cogeneration systems to district heating in South Korea.

    PubMed

    Chung, Mo; Park, Hwa-Choon

    2015-08-01

    A feasibility study was performed to assess the technical and economic merits of retrofitting biogas-based cogeneration systems to district heating networks. Three district heating plants were selected as candidates for accommodating heat recovery from nearby waste treatment stations, where a massive amount of biogas can be produced on a regular basis. The scenario involves constructing cogeneration systems in each waste treatment station and producing electricity and heat. The amounts of biogas production for each station are estimated based on the monthly treatment capacities surveyed over the most recent years. Heat produced by the cogeneration system is first consumed on site by the waste treatment system to keep the operating temperature at a proper level. If surplus heat is available, it will be transported to the nearest district heating plant. The year-round operation of the cogeneration system was simulated to estimate the electricity and heat production. We considered cost associated with the installation of the cogeneration system and piping as initial investments. Profits from selling electricity and recovering heat are counted as income, while costs associated with buying biogas are expenses. Simple payback periods of 2-10 years were projected under the current economic conditions of South Korea. We found that most of the proposed scenarios can contribute to both energy savings and environmental protection. © The Author(s) 2015.

  7. A feasibility assessment for the application of biogas and wind power in the farm environment as sustainable sources of energy

    NASA Astrophysics Data System (ADS)

    Carbo, Laura C.

    The depletion of energy sources and the ever-increasing energy demand---and consequently price escalation---is a problem that concerns the global population. Despite the concept of energy crisis being widely accepted nowadays, there is a lot of scepticism and misinformation on the possible alternatives to alleviate the environmental and economic impacts of conventional energy generation. Renewable energy technologies are constantly experiencing significant innovation and improvements. This thesis sought to assess the potential of small dairy farms to make an energy shift and identify the practical benefits and possible downfalls of this shift. Wind power and biogas digestion were analysed in this thesis, and a model to assess these technologies at any given farm was developed on VBA. For the case studied in this research both technologies were concluded to be feasible from an economic point of view. Although the initial investment can seem costly, considering the relatively low payback period and the currently available subsidies the economic implications are not an obstacle. The model developed on VBA is applicable to any region, given the right data is put into the programme. Considering the global energy concern, models such as the one developed in this thesis are an appropriate tool to identify potential shifts to greener solutions and prove to users that it can be economically profitable for them as well as environmentally beneficial.

  8. Osmosis process for leachate treatment in industrial platform: Economic and performances evaluations to zero liquid discharge.

    PubMed

    Cingolani, Diego; Eusebi, Anna Laura; Battistoni, Paolo

    2017-12-01

    The industrial processes require large quantities of water. The presence of discharges results not only in significant environmental impact but implies wastage of water resources. This problem could be solved treating and reusing the produced wastewaters and applying the new zero liquid discharge approach. This paper discusses the design and the performances of reverse osmosis membranes for the upgrading of full scale platform for industrial liquid wastes. The final effluent from the ultrafiltration unit of the full scale plant was monitored to design the reverse osmosis unit. Previous modelling phase was used to evaluate the specific ordinary and maintenance costs and the final effluent quality (2.7 €/m 3 ). The system was designed in triple stages at different operative pressures. The economic feasibility and the payback period of the technology at different percentages of produced permeate were determined. The recovery of 90% was identified as profitable for the reverse osmosis application. One experimental pilot plant applying the reverse osmosis was used to test the final effluent. Moreover, the same flow was treated with second pilot system based on the forward osmosis process. The final efficiencies were compared. Removals higher than 95% using the reverse system were obtained for the main macropollutants and ions. No sustainable applicability of the forward osmosis was determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The Aircraft Electric Taxi System: A Qualitative Multi Case Study

    NASA Astrophysics Data System (ADS)

    Johnson, Thomas Frank

    The problem this research addresses is the airline industry, and the seemingly unwillingness attitude towards adopting ways to taxi aircraft without utilizing thrust from the main engines. The purpose of the study was to get a better understanding of the decision-making process of airline executives, in respect to investing in cost saving technology. A qualitative research method is used from personal interviews with 24 airline executives from two major U.S. airlines, related industry journal articles, and aircraft performance data. The following three research questions are addressed. RQ1. Does the cost of jet fuel influence airline executives' decision of adopting the aircraft electric taxi system technology? RQ2 Does the measurable payback period for a return on investment influence airline executives' decision of adopting ETS technology? RQ3. Does the amount of government assistance influence airline executives' decision of adopting ETS technology? A multi case research study design is used with a triangulation technique. The participant perceptions indicate the need to reduce operating costs, they have concerns about investment risk, and they are in favor of future government sponsored performance improvement projects. Based on the framework, findings and implications of this study, a future research paper could focus on the positive environmental effects of the ETS application. A study could be conducted on current airport area air quality and the effects that aircraft main engine thrust taxiing has on the surrounding air quality.

  10. Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerrigan, P.; Loomis, H.

    2014-09-01

    The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America program goals, specifically compliance with the DOE Challenge Home Program. BSC consulted on the construction of five test houses by three cold climate production builders in three U.S. cities and worked with the builders to develop a design package tailored to the cost-related impacts for each builder. Also, BSC provided support through performance testing of the five test homes. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive ormore » performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations on the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: adding services to the scope of work for various trades, such as HERS Rater, HVAC contractor; and increased material costs related to the checklists, especially the EPA Indoor airPLUS and EPA WaterSense® Efficient Hot Water Distribution requirement.« less

  11. Techno-economic assessment of Levulinic Acid Plant from Sorghum Bicolor in Indonesia

    NASA Astrophysics Data System (ADS)

    Gozan, M.; Ryan, B.; Krisnandi, Y.

    2018-04-01

    The increasing need of energy is one of the main energy security issues in Indonesia. Hence, alternative energy is needed. Levulinic acid (LA) is among chemical platform used in the synthesis for avariety of high-value materials, such as fuels and commodity chemicals. It is predicted that global LA market demand to reach 3.1 tons in 2016. This study examines industrial processdesign and economic analysis for LA production in Indonesia.Sorghum bicolor was used as feed because of its high cellulose, low lignin contents and availability in Indonesia. The conventional economic problem from biomass based production was diminished sincethe valuable waste from pretreatment processwas sold to otherindustry.This plant was recommended to be built in an industrial estate area in Jawa Timur (East Java) province. Results from simulation using SuperPro Designer 9.0 was used for the techno-economic assessment.The plant assessment showed that the minimum production capacity was 7.7 ton per day to achieve an internal rate of return (IRR) and payback period (PBP) values of 19.61% and 3.93 years, respectively. Sensitivity analysis showed that product selling price was the most predominant factor for IRR, NPV, PBP and ROI. Raw material and water had low effects on those economic parameters. These values indicated that LA plant was feasible to be built in Indonesia.

  12. Thermal Energy Storage for Electricity Peak-demand Mitigation: A Solution in Developing and Developed World Alike

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeForest, Nicholas; Mendes, Goncalo; Stadler, Michael

    2013-06-02

    In much of the developed world, air-conditioning in buildings is the dominant driver of summer peak electricity demand. In the developing world a steadily increasing utilization of air-conditioning places additional strain on already-congested grids. This common thread represents a large and growing threat to the reliable delivery of electricity around the world, requiring capital-intensive expansion of capacity and draining available investment resources. Thermal energy storage (TES), in the form of ice or chilled water, may be one of the few technologies currently capable of mitigating this problem cost effectively and at scale. The installation of TES capacity allows a buildingmore » to meet its on-peak air conditioning load without interruption using electricity purchased off-peak and operating with improved thermodynamic efficiency. In this way, TES has the potential to fundamentally alter consumption dynamics and reduce impacts of air conditioning. This investigation presents a simulation study of a large office building in four distinct geographical contexts: Miami, Lisbon, Shanghai, and Mumbai. The optimization tool DER-CAM (Distributed Energy Resources Customer Adoption Model) is applied to optimally size TES systems for each location. Summer load profiles are investigated to assess the effectiveness and consistency in reducing peak electricity demand. Additionally, annual energy requirements are used to determine system cost feasibility, payback periods and customer savings under local utility tariffs.« less

  13. Selecting a proper design period for heliostat field layout optimization using Campo code

    NASA Astrophysics Data System (ADS)

    Saghafifar, Mohammad; Gadalla, Mohamed

    2016-09-01

    In this paper, different approaches are considered to calculate the cosine factor which is utilized in Campo code to expand the heliostat field layout and maximize its annual thermal output. Furthermore, three heliostat fields containing different number of mirrors are taken into consideration. Cosine factor is determined by considering instantaneous and time-average approaches. For instantaneous method, different design days and design hours are selected. For the time average method, daily time average, monthly time average, seasonally time average, and yearly time averaged cosine factor determinations are considered. Results indicate that instantaneous methods are more appropriate for small scale heliostat field optimization. Consequently, it is proposed to consider the design period as the second design variable to ensure the best outcome. For medium and large scale heliostat fields, selecting an appropriate design period is more important. Therefore, it is more reliable to select one of the recommended time average methods to optimize the field layout. Optimum annual weighted efficiency for heliostat fields (small, medium, and large) containing 350, 1460, and 3450 mirrors are 66.14%, 60.87%, and 54.04%, respectively.

  14. Increase in nitrate uptake by soybean plants during interruption of the dark period with low intensity light

    NASA Technical Reports Server (NTRS)

    Raper, C. D. Jr; Vessey, J. K.; Henry, L. T.

    1991-01-01

    Diurnal patterns of net NO3- uptake by nonnodulated soybean [Glycine max (L.) Merr. cv. Ransom] plants growing in flowing hydroponic culture at 26 and 16 degrees C root temperatures were measured at hourly intervals during alternate days of a 12-day growth period. Ion chromatography was used to determine removal of NO3- from the culture solution. Day and night periods of 9 and 15 h were used during growth. The night period included two 6-h dark periods and an intervening 3-h period of night interruption by incandescent lamps to effect a long-day photoperiod and repress floral initiation. At both root temperatures, the average specific rates of NO3- uptake were twice as great during the night interruption period as during the day period; they were greater during the day period than during the dark periods; and they were greater during the dark period immediately following the day period than during the later dark period that followed the night interruption. While these average patterns were repetitious among days, measured rates of uptake varied hourly and included intervals of net efflux scattered through the day period and more frequently through the 2 dark periods. Root temperature did not affect the average daily specific rates of uptake or the qualitative relationships among day, dark and night interruption periods of the diurnal cycle.

  15. Regional grassland productivity responses to precipitation during multiyear above- and below-average rainfall periods.

    PubMed

    Petrie, Matthew D; Peters, Debra P C; Yao, Jin; Blair, John M; Burruss, Nathan D; Collins, Scott L; Derner, Justin D; Gherardi, Laureano A; Hendrickson, John R; Sala, Osvaldo E; Starks, Patrick J; Steiner, Jean L

    2018-05-01

    There is considerable uncertainty in the magnitude and direction of changes in precipitation associated with climate change, and ecosystem responses are also uncertain. Multiyear periods of above- and below-average rainfall may foretell consequences of changes in rainfall regime. We compiled long-term aboveground net primary productivity (ANPP) and precipitation (PPT) data for eight North American grasslands, and quantified relationships between ANPP and PPT at each site, and in 1-3 year periods of above- and below-average rainfall for mesic, semiarid cool, and semiarid warm grassland types. Our objective was to improve understanding of ANPP dynamics associated with changing climatic conditions by contrasting PPT-ANPP relationships in above- and below-average PPT years to those that occurred during sequences of multiple above- and below-average years. We found differences in PPT-ANPP relationships in above- and below-average years compared to long-term site averages, and variation in ANPP not explained by PPT totals that likely are attributed to legacy effects. The correlation between ANPP and current- and prior-year conditions changed from year to year throughout multiyear periods, with some legacy effects declining, and new responses emerging. Thus, ANPP in a given year was influenced by sequences of conditions that varied across grassland types and climates. Most importantly, the influence of prior-year ANPP often increased with the length of multiyear periods, whereas the influence of the amount of current-year PPT declined. Although the mechanisms by which a directional change in the frequency of above- and below-average years imposes a persistent change in grassland ANPP require further investigation, our results emphasize the importance of legacy effects on productivity for sequences of above- vs. below-average years, and illustrate the utility of long-term data to examine these patterns. © 2018 John Wiley & Sons Ltd.

  16. Indonesia sea surface temperature from TRMM Microwave Imaging (TMI) sensor

    NASA Astrophysics Data System (ADS)

    Marini, Y.; Setiawan, K. T.

    2018-05-01

    We analysis the Tropical Rainfall Measuring Mission's (TRMM) Microwave Imager (TMI) data to monitor the sea surface temperature (SST) of Indonesia waters for a decade of 2005-2014. The TMI SST data shows the seasonal and interannual SST in Indonesian waters. In general, the SST average was highest in March-May period with SST average was 29.4°C, and the lowest was in June – August period with the SST average was 28.5°C. The monthly SST average fluctuation of Indonesian waters for 10 years tends to increase. The lowest SST average of Indonesia occurred in August 2006 with the SST average was 27.6° C, while the maximum occurred in May 2014 with the monthly SST average temperature was 29.9 ° C.

  17. Climate, canopy disturbance, and radial growth averaging in a second-growth mixed-oak forest in West Virginia, USA

    Treesearch

    James S. Rentch; B. Desta Fekedulegn; Gary W. Miller

    2002-01-01

    This study evaluated the use of radial growth averaging as a technique of identifying canopy disturbances in a thinned 55-year-old mixed-oak stand in West Virginia. We used analysis of variance to determine the time interval (averaging period) and lag period (time between thinning and growth increase) that best captured the growth increase associated with different...

  18. A Life Cycle Assessment and Economic Analysis of Wind Turbines Using Monte Carlo Simulation

    DTIC Science & Technology

    2003-03-01

    1,521 1,579 2,699 2,817 1,683 1,849 2,037 1,915 2,008 94849 MI Alpena 806 948 1,110 1,142 1,953 2,068 1,128 1,269 1,434 1,324 1,405 94847 MI Detroit...AK Anchorage, AK Payback (years) 115 0 10 20 30 40 50 60 70 80 Lansing, MI Houghton, MI Grand Rapids, MI Flint, MI Detroit, MI Alpena , MI Portland...Grand Rapids, MI Flint, MI Detroit, MI Alpena , MI Portland, ME Caribou, ME Baltimore, MD Worchester, MA Boston, MA Shreveport, LA New Orleans, LA Lake

  19. Chapter 16: Retrocommissioning Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Tiessen, Alex

    Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.

  20. Purchasing in a supply chain environment.

    PubMed

    Schorr, J E

    2000-08-01

    Why the interest in purchasing? In the typical company, material costs are 40% to 75% of the cost of goods sold, labor is 5% to 15%, and the balance is burden. The typical company has $4-$5 in purchased cost to $1 in labor. Most companies are implementing material requirements planning (MRP II) and enterprise resource planning systems to control the $1 in labor and have little expectation in the area of purchasing savings. Yet a dollar saved in purchasing goes directly to the bottom line. I ran a survey of 100 Class A users of MRP II; in all 100 of the companies, the biggest payback was in the area of purchasing.

  1. Semiconductor grade, solar silicon purification project

    NASA Technical Reports Server (NTRS)

    Ingle, W. M.; Rosler, R. R.; Thompson, S. W.; Chaney, R. E.

    1979-01-01

    Experimental apparatus and procedures used in the development of a 3-step SiF2(x) polymer transport purification process are described. Both S.S.M.S. and E.S. analysis demonstrated that major purification had occured and some samples were indistinguishable from semiconductor grade silicon (except possibly for phosphorus). Recent electrical analysis via crystal growth reveals that the product contains compensated phosphorus and boron. The low projected product cost and short energy payback time suggest that the economics of this process will result in a cost less than the goal of $10/Kg(1975 dollars). The process appears to be readily scalable to a major silicon purification facility.

  2. Particle tower technology applied to metallurgic plants and peak-time boosting of steam power plants

    NASA Astrophysics Data System (ADS)

    Amsbeck, Lars; Buck, Reiner; Prosin, Tobias

    2016-05-01

    Using solar tower technology with ceramic particles as heat transfer and storage medium to preheat scrap for induction furnaces in foundries provides solar generated heat to save electricity. With such a system an unsubsidized payback time of only 4 years is achieved for a 70000t/a foundry in Brazil. The same system can be also used for heat treatment of metals. If electricity is used to heat inert atmospheres a favorable economic performance is also achievable for the particle system. The storage in a particle system enables solar boosting to be restricted to only peak times, enabling an interesting business case opportunity.

  3. Cost Benefit Analysis Modeling Tool for Electric vs. ICE Airport Ground Support Equipment – Development and Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Francfort; Kevin Morrow; Dimitri Hochard

    2007-02-01

    This report documents efforts to develop a computer tool for modeling the economic payback for comparative airport ground support equipment (GSE) that are propelled by either electric motors or gasoline and diesel engines. The types of GSE modeled are pushback tractors, baggage tractors, and belt loaders. The GSE modeling tool includes an emissions module that estimates the amount of tailpipe emissions saved by replacing internal combustion engine GSE with electric GSE. This report contains modeling assumptions, methodology, a user’s manual, and modeling results. The model was developed based on the operations of two airlines at four United States airports.

  4. Personalized Vehicle Energy Efficiency & Range Predictor/MyGreenCar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SAXENA, SAMVEG

    MyGreenCar provides users with the ability to predict the range capabilities, fuel economy, and operating costs for any vehicle for their individual driving patterns. Users launce the MyGreeCar mobile app on their smartphones to collect their driving patterns over any duration (e.g. serval days, weeks, months, etc) using a phones's locational capabilities. Using vehicle powertrain models for any user-specified vehicle type, MyGreenCar, calculates the component-level energy and power interactions for the chosen vehicle to predict several important quantities, including: 1. For Evs: Alleviating range anxiety 2. Comparing fuel economy, operating costs, and payback time across models and types.

  5. Quantification of differences between occupancy and total monitoring periods for better assessment of exposure to particles in indoor environments

    NASA Astrophysics Data System (ADS)

    Wierzbicka, A.; Bohgard, M.; Pagels, J. H.; Dahl, A.; Löndahl, J.; Hussein, T.; Swietlicki, E.; Gudmundsson, A.

    2015-04-01

    For the assessment of personal exposure, information about the concentration of pollutants when people are in given indoor environments (occupancy time) are of prime importance. However this kind of data frequently is not reported. The aim of this study was to assess differences in particle characteristics between occupancy time and the total monitoring period, with the latter being the most frequently used averaging time in the published data. Seven indoor environments were selected in Sweden and Finland: an apartment, two houses, two schools, a supermarket, and a restaurant. They were assessed for particle number and mass concentrations and number size distributions. The measurements using a Scanning Mobility Particle Sizer and two photometers were conducted for seven consecutive days during winter in each location. Particle concentrations in residences and schools were, as expected, the highest during occupancy time. In the apartment average and median PM2.5 mass concentrations during the occupancy time were 29% and 17% higher, respectively compared to total monitoring period. In both schools, the average and medium values of the PM2.5 mass concentrations were on average higher during teaching hours compared to the total monitoring period by 16% and 32%, respectively. When it comes to particle number concentrations (PNC), in the apartment during occupancy, the average and median values were 33% and 58% higher, respectively than during the total monitoring period. In both houses and schools the average and median PNC were similar for the occupancy and total monitoring periods. General conclusions on the basis of measurements in the limited number of indoor environments cannot be drawn. However the results confirm a strong dependence on type and frequency of indoor activities that generate particles and site specificity. The results also indicate that the exclusion of data series during non-occupancy periods can improve the estimates of particle concentrations and characteristics suitable for exposure assessment, which is crucial for estimating health effects in epidemiological and toxicological studies.

  6. Child-Langmuir flow with periodically varying anode voltage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rokhlenko, A.

    Using the Lagrangian technique, we study settled Child-Langmuir flows in a one dimensional planar diodes whose anode voltages periodically vary around given positive values. Our goal is to find analytically if the average currents in these systems can exceed the famous Child-Langmuir limit found for the stationary current a long time ago. The main result of our study is that in a periodic quasi-stationary regime the average current can be larger than the Child-Langmuir maximum even by 50% compared with its adiabatic average value. The cathode current in this case has the form of rectangular pulses which are formed bymore » a very special triangular voltage modulation. This regime, i.e., periodicity, shape of pulses, and their amplitude, needs to be carefully chosen for the best performance.« less

  7. Surface waters of Elk Creek basin in southwestern Oklahoma

    USGS Publications Warehouse

    Westfall, A.O.

    1963-01-01

    The purpose of this study is to (1) determine the average discharge during a period that is representative of average streamflow conditions, (2) determine the range of discharge, and (3) determine the storage required to supplement natural flows during drought periods. Elk Creek drains 587 square miles of the North Fork Red River basin. The climate is subhumid, and precipitation averages about 23 inches per year. The average discharge at the gaging station near Hobart is 50 cfs (cubic feet per second) or 36,200 acre-feet per year during a 19-year base period, water years 1938-56. The yearly average discharge ranged from 4.6 cfs in 1940 to 146 cfs in 1957. Maximum runoff generally occurs during May and June. The maximum monthly runoff was 64,520 acre-feet in May 1957. The maximum yearly runoff was 105,500 acre-feet in 1957. There is no sustained base flow in the basin. Severe droughts occurred in 1938-40 and 1952-56. The most extended drought occurred from June 1951 to March 1957, during which time there was a prolonged period of no flow of 182 days in 1954-55. A usable storage of 28,000 acre-feet would have been required to provide a regulated discharge of 1,500 acre-feet per month throughout these drought periods. (available as photostat copy only)

  8. A comparative statistical study of long-term agroclimatic conditions affecting the growth of US winter wheat: Distributions of regional monthly average precipitation on the Great Plains and the state of Maryland and the effect of agroclimatic conditions on yield in the state of Kansas

    NASA Technical Reports Server (NTRS)

    Welker, J.

    1981-01-01

    A histogram analysis of average monthly precipitation over 30 and 84 year periods for both Maryland and Kansas was made and the results compared. A second analysis, a statistical assessment of the effect of average monthly precipitation on Kansas winter wheat yield was made. The data sets covered the three periods of 1941-1970, 1887-1970, and 1887-1921. Analyses of the limited data sets used (only the average monthly precipitation and temperature were correlated against yield) indicated that fall precipitation values, especially those of September and October, were more important to winter wheat yield than were spring values, particularly for the period 1941-1970.

  9. National Hospital Input Price Index

    PubMed Central

    Freeland, Mark S.; Anderson, Gerard; Schendler, Carol Ellen

    1979-01-01

    The national community hospital input price index presented here isolates the effects of prices of goods and services required to produce hospital care and measures the average percent change in prices for a fixed market basket of hospital inputs. Using the methodology described in this article, weights for various expenditure categories were estimated and proxy price variables associated with each were selected. The index is calculated for the historical period 1970 through 1978 and forecast for 1979 through 1981. During the historical period, the input price index increased an average of 8.0 percent a year, compared with an average rate of increase of 6.6 percent for overall consumer prices. For the period 1979 through 1981, the average annual increase is forecast at between 8.5 and 9.0 percent. Using the index to deflate growth in expenses, the level of real growth in expenditures per inpatient day (net service intensity growth) averaged 4.5 percent per year with considerable annual variation related to government and hospital industry policies. PMID:10309052

  10. National hospital input price index.

    PubMed

    Freeland, M S; Anderson, G; Schendler, C E

    1979-01-01

    The national community hospital input price index presented here isolates the effects of prices of goods and services required to produce hospital care and measures the average percent change in prices for a fixed market basket of hospital inputs. Using the methodology described in this article, weights for various expenditure categories were estimated and proxy price variables associated with each were selected. The index is calculated for the historical period 1970 through 1978 and forecast for 1979 through 1981. During the historical period, the input price index increased an average of 8.0 percent a year, compared with an average rate of increase of 6.6 percent for overall consumer prices. For the period 1979 through 1981, the average annual increase is forecast at between 8.5 and 9.0 per cent. Using the index to deflate growth in expenses, the level of real growth in expenditures per inpatient day (net service intensity growth) averaged 4.5 percent per year with considerable annual variation related to government and hospital industry policies.

  11. Estimation of physical work load by statistical analysis of the heart rate in a conveyor-belt worker.

    PubMed

    Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J

    1994-12-01

    Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.

  12. Decomposition Analyses Applied to a Complex Ultradian Biorhythm: The Oscillating NADH Oxidase Activity of Plasma Membranes Having a Potential Time-Keeping (Clock) Function

    PubMed Central

    Foster, Ken; Anwar, Nasim; Pogue, Rhea; Morré, Dorothy M.; Keenan, T. W.; Morré, D. James

    2003-01-01

    Seasonal decomposition analyses were applied to the statistical evaluation of an oscillating activity for a plasma membrane NADH oxidase activity with a temperature compensated period of 24 min. The decomposition fits were used to validate the cyclic oscillatory pattern. Three measured values, average percentage error (MAPE), a measure of the periodic oscillation, mean average deviation (MAD), a measure of the absolute average deviations from the fitted values, and mean standard deviation (MSD), the measure of standard deviation from the fitted values plus R-squared and the Henriksson-Merton p value were used to evaluate accuracy. Decomposition was carried out by fitting a trend line to the data, then detrending the data if necessary, by subtracting the trend component. The data, with or without detrending, were then smoothed by subtracting a centered moving average of length equal to the period length determined by Fourier analysis. Finally, the time series were decomposed into cyclic and error components. The findings not only validate the periodic nature of the major oscillations but suggest, as well, that the minor intervening fluctuations also recur within each period with a reproducible pattern of recurrence. PMID:19330112

  13. Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less

  14. 40 CFR 80.105 - Reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 1995 averaging period, and for each subsequent averaging period, any refiner for each refinery or group... per million; (E) The difference between the applicable sulfur content standard under § 80.101(b)(1)(ii... olefin content under § 80.101(g) in volume percent; (H) The difference between the applicable olefin...

  15. 40 CFR 86.1370-2007 - Not-To-Exceed test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that include discrete regeneration events and that send a recordable electronic signal indicating the start and end of the regeneration event, determine the minimum averaging period for each NTE event that... averaging period is used to determine whether the individual NTE event is a valid NTE event. For engines...

  16. 7 CFR 760.4 - Normal marketings of milk.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURE SPECIAL PROGRAMS INDEMNITY PAYMENT PROGRAMS Dairy Indemnity Payment Program Payments to Dairy... section are adjusted for any change in the daily average number of cows milked during each pay period the milk is off the market compared with the average number of cows milked daily during the base period. (d...

  17. 20 CFR 654.5 - Classification of labor surplus areas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... unemployment rate for all civilian workers in the civil jurisdiction for the reference period is (1) 120 percent of the national average unemployment rate for civilian workers or higher for the reference period... shall be classified as a labor surplus area if the average unemployment rate for all civilian workers...

  18. Globally Averaged Atmospheric CFC-11 Concentrations: Monthly and Annual Data for the Period 1975-1992 (DB1010)

    DOE Data Explorer

    Khalil, M. A.K. [Oregon Graduate Institute of Science and Technology Portland, Oregon (USA); Rasmussen, R. A. [Oregon Graduate Institute of Science and Technology Portland, Oregon

    1996-01-01

    This data set presents globally averaged atmospheric concentrations of chlorofluorocarbon 11, known also as CFC-11 or F-11 (chemical name: trichlorofluoromethane; formula: CCl3F). The monthly global average data are derived from flask air samples collected at eight sites in six locations over the period August 1980-July 1992. The sites are Barrow (Alaska), Cape Meares (Oregon), Cape Kumukahi and Mauna Loa (Hawaii), Cape Matatula (American Samoa), Cape Grim (Tasmania), Palmer Station, and the South Pole (Antarctica). At each collection site, monthly averages were obtained from three flask samples collected every week. In addition to the monthly global averages available for 1980-992, this data set also contains annual global average data for 1975-1985. These annual global averages were derived from January measurements at the South Pole and in the Pacific Northwest of the United States (specifically, Washington state and the Oregon coast).

  19. Life cycle assessment in support of sustainable transportation

    NASA Astrophysics Data System (ADS)

    Eckelman, Matthew J.

    2013-06-01

    In our rapidly urbanizing world, sustainable transportation presents a major challenge. Transportation decisions have considerable direct impacts on urban society, both positive and negative, for example through changes in transit times and economic productivity, urban connectivity, tailpipe emissions and attendant air quality concerns, traffic accidents, and noise pollution. Much research has been dedicated to quantifying these direct impacts for various transportation modes. Transportation planning decisions also result in a variety of indirect environmental and human health impacts, a portion of which can accrue outside of the transit service area and so outside of the local decision-making process. Integrated modeling of direct and indirect impacts over the life cycle of different transportation modes provides decision support that is more comprehensive and less prone to triggering unintended consequences than a sole focus on direct tailpipe emissions. The recent work of Chester et al (2013) in this journal makes important contributions to this research by examining the environmental implications of introducing bus rapid transit and light rail in Los Angeles using life cycle assessment (LCA). Transport in the LA region is dominated by automobile trips, and the authors show that potential shifts to either bus or train modes would reduce energy use and emissions of criteria air pollutants, on an average passenger mile travelled basis. This work compares not just the use of each vehicle, but also upstream impacts from its manufacturing and maintenance, as well as the construction and maintenance of the entire infrastructure required for each mode. Previous work by the lead author (Chester and Horvath 2009), has shown that these non-operational sources and largely non-local can dominate life cycle impacts from transportation, again on an average (or attributional) basis, for example increasing rail-related GHG emissions by >150% over just operational emissions. While average results are valuable in comparing transport modes generally, they are less representative of local planning decisions, where the focus is on understanding the consequences of new infrastructure and how it might affect traffic, community impacts, and environmental aspects going forward. Chester et al (2013) also present their results using consequential LCA, which provides more detailed insights about the marginal effects of the specific rapid bus and light rail lines under study. The trade-offs between the additional resources required to install the public transit infrastructure (the 'resource debt') and the environmental advantages during the operation of these modes can be considered explicitly in terms of environmental impact payback periods, which vary with the type of environmental impact being considered. For example, bus rapid transit incurs a relatively small carbon debt associated with the GHG emissions of manufacturing new buses and installing transit infrastructure and pays this debt off almost immediately, while it takes half a century for the light rail line to pay off the 'smog debt' of its required infrastructure. This payback period approach, ubiquitous in life cycle costing, has been useful for communicating the magnitude of unintended environmental consequences from other resource and land management decisions, e.g., the release of soil carbon from land conversion to bioenergy crops (Fargione et al 2008), and will likely grow in prevalence as consequential LCA is used for decision support. The locations of projected emissions is just as important to decision-making as their magnitudes, as policy-making bodies seek to understand effects in their jurisdictions; however, life cycle impact assessment methods typically aggregate results by impact category rather than by source or sink location. Chester et al (2013) address this issue by providing both local (within Los Angeles) and total emissions results, with accompanying local-only payback periods. Much more challenging is the geographic mapping of impacts that these emissions will cause, given the many point and mobile sources of air pollutants over the entire transportation life cycle. Integration of LCA with high-resolution data sets is an active area of model development (Mutel and Hellweg 2009) and will provide site- and population-specific information for impacts ranging from water quality to biodiversity to human respiratory health. Another complex challenge in modeling environmental impacts of transportation (and cities in general) is the long run, interdependent relationship between transportation technologies and urban form. LCA modeling has tended to assume a fixed pattern of settlements and demand for mobility and then examined changes to a particular technology or practice within the transportation system, such as electric or hybrid vehicles or improved pavement materials. New transit options or other travel demand management strategies might induce mode switching or reduced trips, but the overall pattern of where people live and work is generally assumed in these models to be constant in the short run. In contrast, the automobile has been influencing land-use patterns for a century, and it is the resulting geographic structure that determines the baseline need for transportation, and thus drives the use of material and energy resources used in transportation systems (Kunstler 1994). We have seen that cities with high population densities tend to have lower tailpipe emissions from transportation (Kennedy et al 2009). Recent studies have modeled how changes in urban land-use or zoning changes the geographic structure of transportation demand and then used LCA to determine the environmental benefits of such policies. For example, Mashayekh et al (2012) summarized travel demand reductions projected from several studies of compact, smart growth, and brownfield in-fill development strategies to find benefits ranging up to 75% reductions in life cycle GHG and air pollutant emissions. A related study in Toronto on life cycle energy use and GHG emissions for high- and low-density development strategies found a ~60% difference in GHG emissions, largely due to transportation (Norman et al 2006). System dynamics and agent-based models may complement LCA in capturing long-term effects of transportation strategies as they are inherently dynamic (Stepp et al 2009), and can internalize spatially resolved decisions about where to settle and work (Waddell 2002). Transportation planning decisions have both direct and indirect, spatially distributed, often long-term effects on our health and our environment. The accompanying work by Chester et al (2013) provides a well-documented case study that highlights the potential of LCA as a rich source of decision support. References Chester M, Pincetl S, Elizabeth Z, Eisenstein W and Matute J 2013 Infrastructure and automobile shifts: positioning transit to reduce life-cycle environmental impacts for urban sustainability goals Environ. Res. Lett. 8 015041 Chester M V and Horvath A 2009 Environmental assessment of passenger transportation should include infrastructure and supply chains Environ. Res. Lett. 4 024008 Fargione J, Hill J, Tilman D, Polasky S and Hawthorne P 2008 Land clearing and the biofuel carbon debt Science 319 1235-8 Kennedy C, Steinberger J, Gasson B, Hansen Y, Hillman T, Havránek M, Pataki D, Phdungsilp A, Ramaswami A and Mendez G V 2009 Greenhouse gas emissions from global cities Environ. Sci. Technol. 43 7297-302 Kunstler J H 1994 Geography of Nowhere: The Rise and Decline of America's Man-Made Landscape (New York: Free Press) Mashayekh Y, Jaramillo P, Samaras C, Hendrickson C T, Blackhurst M, MacLean H L and Matthews H S 2012 Potentials for sustainable transportation in cities to alleviate climate change impacts Environ. Sci. Technol. 46 2529-37 Mutel C L and Hellweg S 2009 Regionalized life cycle assessment: computational methodology and application to inventory databases Environ. Sci. Technol. 43 5797-803 Norman J, MacLean H L and Kennedy C A 2006 Comparing high and low residential density: life-cycle analysis of energy use and greenhouse gas emissions J. Urban Plann. Dev. 132 10-21 Stepp M D, Winebrake J J, Hawker J S and Skerlos S J 2009 Greenhouse gas mitigation policies and the transportation sector: the role of feedback effects on policy effectiveness Energy Policy 37 2774-87 Waddell P 2002 UrbanSim: modeling urban development for land use, transportation, and environmental planning J. Am. Plann. Assoc. 68 297-314

  20. 24 CFR 92.222 - Reduction of matching contribution requirement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... period specified in paragraph (a)(4) of this section. (i) Poverty rate. The average poverty rate in the participating jurisdiction was equal to or greater than 125 percent of the average national poverty rate during... be reduced by 50 percent, for the period specified in paragraph (a)(4) of this section. (i) Poverty...

  1. 13 CFR 121.106 - How does SBA calculate number of employees?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... average number of employees is used for each of the pay periods during which it has been in business. (4... includes the following principles: (1) The average number of employees of the concern is used (including... pay periods for the preceding completed 12 calendar months. (2) Part-time and temporary employees are...

  2. 13 CFR 121.106 - How does SBA calculate number of employees?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... average number of employees is used for each of the pay periods during which it has been in business. (4... includes the following principles: (1) The average number of employees of the concern is used (including... pay periods for the preceding completed 12 calendar months. (2) Part-time and temporary employees are...

  3. 12 CFR 1777.10 - Developments prompting supervisory response.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) An Enterprise's publicly reported net income for the most recent calendar quarter is less than one-half of its average quarterly net income for any four-quarter period during the prior eight quarters... than one-half of its average NIM for any four-quarter period during the prior eight quarters; (d) For...

  4. 40 CFR 80.80 - Penalties.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... penalty of not more than the sum of $25,000 for every day of each such violation and the amount of... every day in the averaging period. Any violation of any credit creation or credit transfer requirement shall constitute a separate day of violation for each and every day in the averaging period. (d)(1)(i...

  5. 24 CFR 92.222 - Reduction of matching contribution requirement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... period specified in paragraph (a)(4) of this section. (i) Poverty rate. The average poverty rate in the participating jurisdiction was equal to or greater than 125 percent of the average national poverty rate during... be reduced by 50 percent, for the period specified in paragraph (a)(4) of this section. (i) Poverty...

  6. 24 CFR 92.222 - Reduction of matching contribution requirement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... period specified in paragraph (a)(4) of this section. (i) Poverty rate. The average poverty rate in the participating jurisdiction was equal to or greater than 125 percent of the average national poverty rate during... be reduced by 50 percent, for the period specified in paragraph (a)(4) of this section. (i) Poverty...

  7. 24 CFR 92.222 - Reduction of matching contribution requirement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... period specified in paragraph (a)(4) of this section. (i) Poverty rate. The average poverty rate in the participating jurisdiction was equal to or greater than 125 percent of the average national poverty rate during... be reduced by 50 percent, for the period specified in paragraph (a)(4) of this section. (i) Poverty...

  8. 24 CFR 92.222 - Reduction of matching contribution requirement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... period specified in paragraph (a)(4) of this section. (i) Poverty rate. The average poverty rate in the participating jurisdiction was equal to or greater than 125 percent of the average national poverty rate during... be reduced by 50 percent, for the period specified in paragraph (a)(4) of this section. (i) Poverty...

  9. Risk for Sleep Disorder Measured during Students' First College Semester May Predict Institutional Retention and Grade Point Average over a 3-Year Period, with Indirect Effects through Self-Efficacy

    ERIC Educational Resources Information Center

    Gaultney, Jane F.

    2016-01-01

    The present study used a validated survey to assess freshmen college students' sleep patterns and risk for sleep disorders and then examined associations with retention and grade point average (GPA) over a 3-year period. Students at risk for a sleep disorder were more likely to leave the institution over the 3-year period, although this…

  10. 7 CFR 59.200 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... these same swine. Average lean percentage. The term “average lean percentage” means the value equal to the average percentage of the carcass weight comprised of lean meat for the swine slaughtered during the applicable reporting period. Whenever the packer changes the manner in which the average lean...

  11. 7 CFR 59.200 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... these same swine. Average lean percentage. The term “average lean percentage” means the value equal to the average percentage of the carcass weight comprised of lean meat for the swine slaughtered during the applicable reporting period. Whenever the packer changes the manner in which the average lean...

  12. Solar energy system economic evaluation: IBM System 4, Clinton, Mississippi

    NASA Technical Reports Server (NTRS)

    1980-01-01

    An economic analysis of the solar energy system was developed for five sites, typical of a wide range of environmental and economic conditions in the continental United States. The analysis was based on the technical and economic models in the F-chart design procedure, with inputs based on the characteristic of the installed system and local conditions. The results are of the economic parameters of present worth of system cost over a 20 year time span: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

  13. Capture of liquid hydrogen boiloff with metal hydride absorbers

    NASA Technical Reports Server (NTRS)

    Rosso, M. J.; Golben, P. M.

    1984-01-01

    A procedure which uses metal hydrides to capture some of this low pressure (,1 psig) hydrogen for subsequent reliquefaction is described. Of the five normally occurring sources of boil-off vapor the stream associated with the off-loading of liquid tankers during dewar refill was identified as the most cost effective and readily recoverable. The design, fabrication and testing of a proof-of-concept capture device, operating at a rate that is commensurate with the evolution of vapor by the target stream, is described. Liberation of the captured hydrogen gas at pressure .15 psig at normal temperatures (typical liquefier compressor suction pressure) are also demonstrated. A payback time of less than three years is projected.

  14. Study of the application of solar chemical dehumidification system to wind tunnel facilities of NASA Lewis Research Center at Cleveland, Ohio

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Energy utilization and cost payback analyses were prepared for proposed modifications. A 50,000 CFM standard compact packaged solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing solar energy and is stored in a storage tank. A steam boiler is provided as a back-up for the solar system. A 50,000 CFM standard compact package solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing a steam boiler and a heat exchanger and is stored in a storage tank.

  15. Defining quality health care with outcomes assessment while achieving economic value.

    PubMed

    Shaw, L J; Miller, D D

    2000-02-01

    The effectiveness of a procedure is increasingly guided by the evaluation of patient outcomes. Outcomes data is used to develop clinical pathways of care and to define appropriate resource-use levels without sacrificing quality of care. Integration of the economic implications of medical services into an outcome-based guideline allows for the development of disease-management strategies. In cardiovascular medicine, risk reduction is associated with high cost due to the "pay-back" of new technologies and therapies. A major challenge is to define a balance between "high tech" care and cost. This paper devises an outpatient evidence-based guideline using clinical and economic outcomes data for the diagnosis of coronary disease.

  16. Analysis and evaluation in the production process and equipment area of the low-cost solar array project

    NASA Technical Reports Server (NTRS)

    Goldman, H.; Wolf, M.

    1979-01-01

    The energy consumed in manufacturing silicon solar cell modules was calculated for the current process, as well as for 1982 and 1986 projected processes. In addition, energy payback times for the above three sequences are shown. The module manufacturing energy was partitioned two ways. In one way, the silicon reduction, silicon purification, sheet formation, cell fabrication, and encapsulation energies were found. In addition, the facility, equipment, processing material and direct material lost-in-process energies were appropriated in junction formation processes and full module manufacturing sequences. A brief methodology accounting for the energy of silicon wafers lost-in-processing during cell manufacturing is described.

  17. Energy Efficiency Improvement and Cost Saving Oportunities for the Concrete Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kermeli, Katerina; Worrell, Ernst; Masanet, Eric

    2011-12-01

    The U.S. concrete industry is the main consumer of U.S.-produced cement. The manufacturing of ready mixed concrete accounts for more than 75% of the U.S. concrete production following the manufacturing of precast concrete and masonry units. The most significant expenditure is the cost of materials accounting for more than 50% of total concrete production costs - cement only accounts for nearly 24%. In 2009, energy costs of the U.S. concrete industry were over $610 million. Hence, energy efficiency improvements along with efficient use of materials without negatively affecting product quality and yield, especially in times of increased fuel and materialmore » costs, can significantly reduce production costs and increase competitiveness. The Energy Guide starts with an overview of the U.S. concrete industry’s structure and energy use, a description of the various manufacturing processes, and identification of the major energy consuming areas in the different industry segments. This is followed by a description of general and process related energy- and cost-efficiency measures applicable to the concrete industry. Specific energy and cost savings and a typical payback period are included based on literature and case studies, when available. The Energy Guide intends to provide information on cost reduction opportunities to energy and plant managers in the U.S. concrete industry. Every cost saving opportunity should be assessed carefully prior to implementation in individual plants, as the economics and the potential energy and material savings may differ.« less

  18. Economic assessment and energy model scenarios of municipal solid waste incineration and gas turbine hybrid dual-fueled cycles in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Udomsri, Seksan, E-mail: seksan.udomsri@energy.kth.s; Martin, Andrew R.; Fransson, Torsten H.

    Finding environmentally benign methods related to sound municipal solid waste (MSW) management is of highest priority in Southeast Asia. It is very important to study new approaches which can reduce waste generation and simultaneously enhance energy recovery. One concrete example of particular significance is the concept of hybrid dual-fuel power plants featuring MSW and another high-quality fuel like natural gas. The hybrid dual-fuel cycles provide significantly higher electrical efficiencies than a composite of separate single-fuel power plant (standalone gas turbine combined cycle and MSW incineration). Although hybrid versions are of great importance for energy conversion from MSW, an economic assessmentmore » of these systems must be addressed for a realistic appraisal of these technologies. This paper aims to further examine an economic assessment and energy model analysis of different conversion technologies. Energy models are developed to further refine the expected potential of MSW incineration with regards to energy recovery and environmental issues. Results show that MSW incineration can play role for greenhouse gas reduction, energy recovery and waste management. In Bangkok, the electric power production via conventional incineration and hybrid power plants can cover 2.5% and 8% of total electricity consumption, respectively. The hybrid power plants have a relative short payback period (5 years) and can further reduce the CO{sub 2} levels by 3% in comparison with current thermal power plants.« less

  19. Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperaturemore » modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.« less

  20. Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Dentz; E. Ansanelli, H. Henderson, Jr.; K. Varshney

    Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperaturemore » modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.« less

  1. Learning-Based Research: The Re-Integration of Learning Styles into STEM Research Through the Context of Solar Energy and Climate Literacy

    NASA Astrophysics Data System (ADS)

    Bosman, L.

    2014-12-01

    This presentation will provide an overview of a NASA NICE-T funded research project at the College of Menominee Nation, a small federally recognized Tribal College located in northern Wisconsin. One main objective of the research project is to provide an experiential learning opportunity for 4-6 STEM students to construct a user friendly solar energy system evaluation tool, incorporating the real-world performance of different solar modules at Argonne National Laboratory, NASA weather and solar irradiation data, and detailed cost analysis and investment payback period. A natural connection exists between Native Americans and renewable energy. The generally clean character of renewable energies provides a great synergy and complimentary attribute for Native Americans' respect and pride for the environment and the overarching concern for future generations (Council, Pierce et al. 2000). Furthermore, Native American cultures have a strong creative and artistic focus, often motivated by their respect and appreciation for nature. The purpose of this learning-based research is to apply a cross-disciplinary approach to integrate the humanities with STEM research within the context of solar energy and climate literacy. Using 7 different learning styles (visual, aural, verbal, physical, logical, social, and solitary), students have the opportunity to showcase their research efforts through a variety of modes and artifacts including graphic novel development (Visual), spoken word poetry (Aural), conference presentation (Verbal), experiential display and demonstration (Physical), debate (Logical), social media and viral messaging (Social), and article submission (Solitary).

  2. Heating facilities: Klamath Lutheran Church, Klamath Falls, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-08-01

    The Klamath Lutheran Church is a masonry structure with cathedral ceiling containing approximately 5800 sq ft of floor area. This building is currently heated by two duct furnaces and a unit heater all of which are gas fired. An Educational Wing of approximately 6300 sq ft was added in 1958. This building, containing 2 assembly rooms and a number of classrooms is of uninsulated frame construction, with extensive glass area. A gas-fired boiler supplying finned tube radiators currently heats this wing. Four specific options for displacing all or part of the heating duty with geothermal were examined. These options are:more » case 1 - drilling a production and injection well on the property and using the resultant hot water (180/sup 0/F) to heat the entire facility; case 3 - using effluent from the Klamath Union High School to heat the entire facility; no well drilling required; case 2 - using effluent from the Klamath Union High School to heat only the church building; the present gas boiler would heat the Educational Wing; and case 4 - drilling a production and injection well on the property and using the resulting water (70/sup 0/F) to supply a water-to-water heat pump. Of the four cases examined, case 3 (heating of both the church building and educational wing with effluent from the Klamath Union High School) seems to offer the greatest potential and earliest simple payback period. (MHR)« less

  3. Comparative life cycle assessment and life cycle costing of four disposal scenarios for used polyethylene terephthalate bottles in Mauritius.

    PubMed

    Foolmaun, Rajendra Kumar; Ramjeeawon, Toolseeram

    2012-09-01

    The annual rise in population growth coupled with the flourishing tourism industry in Mauritius has lead to a considerable increase in the amount of solid waste generated. In parallel, the disposal of non-biodegradable wastes, especially plastic packaging and plastic bottles, has also shown a steady rise. Improper disposal of used polyethylene terephthalate (PET) bottles constitutes an eyesore to the environmental landscape and is a threat to the flourishing tourism industry. It is of utmost importance, therefore, to determine a suitable disposal method for used PET bottles which is not only environmentally efficient but is also cost effective. This study investigated the environmental impacts and the cost effectiveness of four selected disposal alternatives for used PET bottles in Mauritius. The four disposal routes investigated were: 100% landfilling; 75% incineration with energy recovery and 25% landfilling; 40% flake production (partial recycling) and 60% landfilling; and 75% flake production and 25% landfilling. Environmental impacts of the disposal alternatives were determined using ISO standardized life cycle assessment (LCA) and with the support of SimaPro 7.1 software. Cost effectiveness was determined using life cycle costing (LCC). Collected data were entered into a constructed Excel-based model to calculate the different cost categories, Net present values, damage costs and payback periods. LCA and LCC results indicated that 75% flake production and 25% landfilling was the most environmentally efficient and cost-effective disposal route for used PET bottles in Mauritius.

  4. A project of reuse of reclaimed wastewater in the Po Valley, Italy: Polishing sequence and cost benefit analysis

    NASA Astrophysics Data System (ADS)

    Verlicchi, P.; Al Aukidy, M.; Galletti, A.; Zambello, E.; Zanni, G.; Masotti, L.

    2012-04-01

    SummaryThe paper presents a study carried out in the environmentally sensitive area of the Po Valley in northern Italy, with the aim of evaluating, from technical and economic perspectives, a project to reuse part of the final effluent from the Ferrara wastewater treatment plant for irrigation and to develop the site for recreational purposes. Although this area features plentiful supplies of surface water, the Ministry of the Environment has declared it to be at risk of environmental crises due to eutrophication and the drought recurring over the last decade. Thus the availability of fresh water, particularly for agricultural purposes, is threatened, and prompt water saving and protection measures are required. Hence, the possibility of reusing reclaimed wastewater from this plant was investigated, with the aim of exploiting the space around the WWTP, situated within a large urban park, to install natural polishing treatment systems and create green spaces for recreational use. Based on experimental investigation on a pilot plant (featuring both natural and conventional treatments), the study outlines the rationale behind the treatment train selected for the project, details the initial and ongoing costs involved, evaluates the benefits deriving from the project, and assesses public acceptance of the project by the contingent valuation method. A cost-benefit analysis completes the study, and various economic indicators (net present value, benefit-cost ratio, pay-back period, and internal rate of return) revealed that the proposed project was financially feasible.

  5. Integrated Assessment of Palm Oil Mill Residues to Sustainable Electricity System (POMR-SES): A Case Study from Peninsular Malaysia

    NASA Astrophysics Data System (ADS)

    Jaye, I. F. Md; Sadhukhan, J.; Murphy, R. J.

    2018-05-01

    Generating electricity from biomass are undeniably gives huge advantages to the energy security, environmental protection and the social development. Nevertheless, it always been negatively claimed as not economically competitive as compared to the conventional electricity generation system using fossil fuel. Due to the unfair subsidies given to renewable energy based fuel and the maturity of conventional electricity generation system, the commercialization of this system is rather discouraging. The uniqueness of the chemical and physical properties of the biomass and the functionality of the system are fully depending on the availability of the biomass resources, the capital expenditure of the system is relatively expensive. To remain competitive, biomass based system must be developed in their most economical form. Therefore the justification of the economies of scale of such system is become essential. This study will provide a comprehensive review of process to select an appropriate size for electricity generation plant from palm oil mill (POM) residues through the combustion of an empty fruit bunch (EFB) and biogas from the anaerobic digestion of palm oil mill effluent (POME) in Peninsular Malaysia using a mathematical model and simulation using ASPEN Plus software package. The system operated at 4 MW capacity is expected to provide a return on investment (ROI) of 20% with a payback period of 6.5 years. It is notably agreed that the correct selection of generation plant size will have a significant impact on overall economic and environmental feasibility of the system.

  6. Building America Case Study: Meeting DOE Challenge Home Program Certification, Chicago, Illinois; Denver, Colorado; Devens, Massachusetts (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. BSC consulted on the construction of five test houses by three Cold Climate production builders in three separate US cities. BSC worked with the builders to develop a design package tailored to the cost-related impacts for each builder. Therefore, the resulting design packages do vary from builder to builder. BSC provided support through this research project on the design, construction and performance testing ofmore » the five test homes. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations on the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: 1. Adding services to the scope of work for various trades, such as HERS Rater, HVAC contractor. 2. Increased material costs related to the checklists, especially the EPA Indoor airPLUS and EPA WaterSense Efficient Hot Water Distribution requirement.« less

  7. Evaluation of the U.S. Department of Energy Challenge Home Program Certification of Production Builders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerrigan, P.; Loomis, H.

    2014-09-01

    The purpose of this project was to evaluate integrated packages of advanced measures in individual test homes to assess their performance with respect to Building America Program goals, specifically compliance with the DOE Challenge Home Program. BSC consulted on the construction of five test houses by three Cold Climate production builders in three separate US cities. BSC worked with the builders to develop a design package tailored to the cost-related impacts for each builder. Therefore, the resulting design packages do vary from builder to builder. BSC provided support through this research project on the design, construction and performance testing ofmore » the five test homes. Overall, the builders have concluded that the energy related upgrades (either through the prescriptive or performance path) represent reasonable upgrades. The builders commented that while not every improvement in specification was cost effective (as in a reasonable payback period), many were improvements that could improve the marketability of the homes and serve to attract more energy efficiency discerning prospective homeowners. However, the builders did express reservations on the associated checklists and added certifications. An increase in administrative time was observed with all builders. The checklists and certifications also inherently increase cost due to: 1. Adding services to the scope of work for various trades, such as HERS Rater, HVAC contractor; 2. Increased material costs related to the checklists, especially the EPA Indoor airPLUS and EPA WaterSense(R) Efficient Hot Water Distribution requirement.« less

  8. Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dentz, Jordan; Ansanelli, Eric; Henderson, Hugh

    Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperaturemore » modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.« less

  9. Converting campus waste into renewable energy - a case study for the University of Cincinnati.

    PubMed

    Tu, Qingshi; Zhu, Chao; McAvoy, Drew C

    2015-05-01

    This paper evaluates the implementation of three waste-to-energy projects at the University of Cincinnati: waste cooking oil-to-biodiesel, waste paper-to-fuel pellets and food waste-to-biogas, respectively. The implementation of these waste-to-energy (WTE) projects would lead to the improvement of campus sustainability by minimizing waste management efforts and reducing GHG emissions via the displacement of fossil fuel usage. Technical and economic aspects of their implementation were assessed and the corresponding GHG reduction was estimated. Results showed that on-site implementation of these projects would: (1) divert 3682L (974 gallons) of waste cooking oil to 3712L (982 gallons) of biodiesel; (2) produce 138tonnes of fuel pellets from 133tonnes of waste paper (with the addition of 20.75tonnes of plastics) to replace121tonnes of coal; and (3) produce biogas that would be enough to replace 12,767m(3) natural gas every year from 146tonnes of food waste. The economic analysis determined that the payback periods for the three projects would be 16months for the biodiesel, 155months for the fuel pellet, and 74months for the biogas projects. The reduction of GHG emission from the implementation of the three WTE projects was determined to be 9.37 (biodiesel), 260.49 (fuel pellets), and 11.36 (biogas) tonnes of CO2-eq per year, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Economic assessment and energy model scenarios of municipal solid waste incineration and gas turbine hybrid dual-fueled cycles in Thailand.

    PubMed

    Udomsri, Seksan; Martin, Andrew R; Fransson, Torsten H

    2010-07-01

    Finding environmentally benign methods related to sound municipal solid waste (MSW) management is of highest priority in Southeast Asia. It is very important to study new approaches which can reduce waste generation and simultaneously enhance energy recovery. One concrete example of particular significance is the concept of hybrid dual-fuel power plants featuring MSW and another high-quality fuel like natural gas. The hybrid dual-fuel cycles provide significantly higher electrical efficiencies than a composite of separate single-fuel power plant (standalone gas turbine combined cycle and MSW incineration). Although hybrid versions are of great importance for energy conversion from MSW, an economic assessment of these systems must be addressed for a realistic appraisal of these technologies. This paper aims to further examine an economic assessment and energy model analysis of different conversion technologies. Energy models are developed to further refine the expected potential of MSW incineration with regards to energy recovery and environmental issues. Results show that MSW incineration can play role for greenhouse gas reduction, energy recovery and waste management. In Bangkok, the electric power production via conventional incineration and hybrid power plants can cover 2.5% and 8% of total electricity consumption, respectively. The hybrid power plants have a relative short payback period (5 years) and can further reduce the CO(2) levels by 3% in comparison with current thermal power plants. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  11. The temporal organization of behavior on periodic food schedules.

    PubMed Central

    Reid, A K; Bacha, G; Morán, C

    1993-01-01

    Various theories of temporal control and schedule induction imply that periodic schedules temporally modulate an organism's motivational states within interreinforcement intervals. This speculation has been fueled by frequently observed multimodal activity distributions created by averaging across interreinforcement intervals. We tested this hypothesis by manipulating the cost associated with schedule-induced activities and the availability of other activities to determine the degree to which (a) the temporal distributions of activities within the interreinforcement interval are fixed or can be temporally displaced, (b) rats can reallocate activities across different interreinforcement intervals, and (c) noninduced activities can substitute for schedule-induced activities. Obtained multimodal activity distributions created by averaging across interreinforcement intervals were not representative of the transitions occurring within individual intervals, so the averaged multimodal distributions should not be assumed to represent changes in the subject's motivational states within the interval. Rather, the multimodal distributions often result from averaging across interreinforcement intervals in which only a single activity occurs. A direct influence of the periodic schedule on the motivational states implies that drinking and running should occur at different periods within the interval, but in three experiments the starting times of drinking and running within interreinforcement intervals were equal. Thus, the sequential pattern of drinking and running on periodic schedules does not result from temporal modulation of motivational states within interreinforcement intervals. PMID:8433061

  12. Payback time: the associations of debt and income with medical student career choice.

    PubMed

    Grayson, Martha S; Newton, Dale A; Thompson, Lori F

    2012-10-01

    With impending health care reform in the USA, there is an imperative to increase the number of students choosing primary care (PC) careers. Research is needed to better understand the roles of economic factors in medical student career choice. The objective of this study was to examine the relationships among debt, income and career choice by comparing students planning PC careers with those aspiring to one of the 12 non-PC fields in which median income exceeds US$300 000 ('high-paying non-primary care' [HPNPC]). Surveys (response rate = 81%) were administered to Year 1 students scheduled to graduate between 1996 and 2012, and Year 4 students graduating between 1993 and 2010. Respondents were students at New York Medical College and East Carolina University's Brody School of Medicine. Analyses focused on the 2674 Year 1 respondents choosing a PC (n = 1437, 54%) or HPNPC (n = 1237, 46%) career, and the 2307 Year 4 respondents intending to pursue PC (n = 992, 43%) or HPNPC (n = 1315, 57%). Longitudinal analyses examining changes in career goals during medical school were based on students who completed surveys in both Years 1 and 4. The outcome measures studied were self-reported debt, anticipated income and self-rated value placed on income. Relative to their PC counterparts, students intending to pursue HPNPC careers anticipated an average of US$24 904 (Year 4 students) or US$29 237 (Year 1 students) greater debt, placed a higher importance value on income, and anticipated earning an average of US$58 463 (Year 1 students) and US$89 909 (Year 4 students) more in annual income after graduation. Debt was associated with the value placed on income in the choice of career and the amount of future income anticipated. Students who valued income highly were especially inclined to switch from PC during medical school. The switch away from PC was associated with debt, as well as with a marked increase in anticipated income. Debt and anticipated income are important concerns which may shape future supplies of PC doctors. © Blackwell Publishing Ltd 2012.

  13. Adrenaline (epinephrine) dosing period and survival after in-hospital cardiac arrest: a retrospective review of prospectively collected data.

    PubMed

    Warren, Sam A; Huszti, Ella; Bradley, Steven M; Chan, Paul S; Bryson, Chris L; Fitzpatrick, Annette L; Nichol, Graham

    2014-03-01

    Expert guidelines for treatment of cardiac arrest recommend administration of adrenaline (epinephrine) every three to five minutes. However, the effects of different dosing periods of epinephrine remain unclear. We sought to evaluate the association between epinephrine average dosing period and survival to hospital discharge in adults with an in-hospital cardiac arrest (IHCA). We performed a retrospective review of prospectively collected data on 20,909 IHCA events from 505 hospitals participating in the Get With The Guidelines-Resuscitation (GWTG-R) quality improvement registry. Epinephrine average dosing period was defined as the time between the first epinephrine dose and the resuscitation endpoint, divided by the total number of epinephrine doses received subsequent to the first epinephrine dose. Associations with survival to hospital discharge were assessed by using generalized estimating equations to construct multivariable logistic regression models. Compared to a referent epinephrine average dosing period of 4 to <5 min per dose, survival to hospital discharge was significantly higher in patients with the following epinephrine average dosing periods: for 6 to <7 min/dose, adjusted odds ratio [OR], 1.41 (95%CI: 1.12, 1.78); for 7 to <8 min/dose, adjusted OR, 1.30 (95%CI: 1.02, 1.65); for 8 to <9 min/dose, adjusted OR, 1.79 (95%CI: 1.38, 2.32); for 9 to <10 min/dose, adjusted OR, 2.17 (95%CI: 1.62, 2.92). This pattern was consistent for both shockable and non-shockable cardiac arrest rhythms. Less frequent average epinephrine dosing than recommended by consensus guidelines was associated with improved survival of in-hospital cardiac arrest. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Interpretation of link fluctuations in climate networks during El Niño periods

    NASA Astrophysics Data System (ADS)

    Martin, E. A.; Paczuski, M.; Davidsen, J.

    2013-05-01

    Recent work has shown that the topologies of functional climate networks are sensitive to El Niño events. One important interpretation of the findings was that parts of the globe act in correlated relationships which become weaker, on average, during El Niño periods (this was shown using monthly averaged data where no time lag is required, and with daily averaged data where time lags were utilized). In contrast to this, we show that El Niño periods actually exhibit higher correlations than “Normal” climate conditions, while typically having lower correlations than La Niña periods. We also show that it is crucial to establish the sensitivity and the robustness of a given method used to extract functional climate networks —parameters such as time lags can significantly influence and even totally alter the outcome.

  15. 78 FR 75432 - Self-Regulatory Organizations; New York Stock Exchange LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-11

    ... Proposed Rule Change To Amend Its Price List To Specify the Exclusion of Odd Lot Transactions From Consolidated Average Daily Volume Calculations for a Limited Period of Time for Purposes of Certain Transaction... transactions from consolidated average daily volume (``CADV'') calculations for a limited period of time for...

  16. Passive magnetic bearing systems stabilizer/bearing utilizing time-averaging of a periodic magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Post, Richard F.

    A high-stiffness stabilizer/bearings for passive magnetic bearing systems is provide where the key to its operation resides in the fact that when the frequency of variation of the repelling forces of the periodic magnet array is large compared to the reciprocal of the growth time of the unstable motion, the rotating system will feel only the time-averaged value of the force. When the time-averaged value of the force is radially repelling by the choice of the geometry of the periodic magnet array, the Earnshaw-related unstable hit motion that would occur at zero rotational speed is suppressed when the system ismore » rotating at operating speeds.« less

  17. 40 CFR 60.758 - Recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to demonstrate compliance with § 60.752(b)(2)(iii) through use of an enclosed combustion device other...: (i) The average combustion temperature measured at least every 15 minutes and averaged over the same... periods of operation during which the average combustion temperature was more than 28 oC below the average...

  18. 40 CFR 60.758 - Recordkeeping requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to demonstrate compliance with § 60.752(b)(2)(iii) through use of an enclosed combustion device other...: (i) The average combustion temperature measured at least every 15 minutes and averaged over the same... periods of operation during which the average combustion temperature was more than 28 oC below the average...

  19. Average cross-responses in correlated financial markets

    NASA Astrophysics Data System (ADS)

    Wang, Shanshan; Schäfer, Rudi; Guhr, Thomas

    2016-09-01

    There are non-vanishing price responses across different stocks in correlated financial markets, reflecting non-Markovian features. We further study this issue by performing different averages, which identify active and passive cross-responses. The two average cross-responses show different characteristic dependences on the time lag. The passive cross-response exhibits a shorter response period with sizeable volatilities, while the corresponding period for the active cross-response is longer. The average cross-responses for a given stock are evaluated either with respect to the whole market or to different sectors. Using the response strength, the influences of individual stocks are identified and discussed. Moreover, the various cross-responses as well as the average cross-responses are compared with the self-responses. In contrast to the short-memory trade sign cross-correlations for each pair of stocks, the sign cross-correlations averaged over different pairs of stocks show long memory.

  20. Measurement in a marine environment using low cost sensors of temperature and dissolved oxygen

    USGS Publications Warehouse

    Godshall, F.A.; Cory, R.L.; Phinney, D.E.

    1974-01-01

    Continuous records of physical parameters of the marine environment are difficult as well as expensive to obtain. This paper describes preliminary results of an investigative program with the purpose of developing low cost time integrating measurement and averaging devices for water temperature and dissolved oxygen. Measurements were made in an estuarine area of the Chesapeake Bay over two week periods. With chemical thermometers average water temperature for the two week period was found to be equal to average water temperature measured with thermocouples plus or minus 1.0 C. The slow diffusion of oxygen through the semipermiable sides of plastic bottles permitted the use of water filled bottles to obtain averaged oxygen measurements. Oxygen measurements for two week averaging times using 500 ml polyethylene bottles were found to vary from conventionally measured and averaged dissolved oxygen by about 1.8 mg/l. ?? 1974 Estuarine Research Federation.

  1. Average bond energies between boron and elements of the fourth, fifth, sixth, and seventh groups of the periodic table

    NASA Technical Reports Server (NTRS)

    Altshuller, Aubrey P

    1955-01-01

    The average bond energies D(gm)(B-Z) for boron-containing molecules have been calculated by the Pauling geometric-mean equation. These calculated bond energies are compared with the average bond energies D(exp)(B-Z) obtained from experimental data. The higher values of D(exp)(B-Z) in comparison with D(gm)(B-Z) when Z is an element in the fifth, sixth, or seventh periodic group may be attributed to resonance stabilization or double-bond character.

  2. Estimating energy intensity and CO{sub 2} emission reduction potentials in the manufacturing sectors in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wangskarn, P.; Khummongkol, P.; Schrattenholzer, L.

    The final energy consumption in Thailand increased at about ten percent annually within the last 10 years. To slow the energy demand growth rate while maintaining the country`s economic advance and environmental sustainability, the Energy Conservation Promotion Act (ECPA) was adopted in 1992. With this Act, a comprehensive Energy Conservation Program (ENCON) was initiated. ENCON commits the government to promoting energy conservation, to developing appropriate regulations, and to providing financial and organizational resources for program implementation. Due to this existing ENCON program a great benefit is expected not only to reducing energy consumption, but also to decreasing GHGs emissions substantially.more » This study is a part of the ENCON research program which was supported by the German Federal Government under the program called Prompt-Start Measures to Implement the U.N. Framework Convention on Climate Change (FCCC). The basic activities carried out during the project included (1) An assessment of Thailand`s total and specific energy consumption in the industrial sectors and commercial buildings; (2) Identification of existing and candidate technologies for GHG emission reduction and energy efficiency improvements in specific factories and commercial buildings; and (3) Identification of individual factories and commercial buildings as candidates for detailed further study. Although the energy assessment had been carried out for the commercial buildings also, this paper will cover only the work on the manufacturing sector. On the basis of these steps, 14 factories were visited by the project team and preliminary energy audits were performed. As a result, concrete measures and investments were proposed and classified into two groups according to their economic characteristics. Those investments with a payback time of less than four years were considered together in a Moderate scenario, and those with longer payback times in an Intensive scenario.« less

  3. Electricity as Transportation ``Fuel''

    NASA Astrophysics Data System (ADS)

    Tamor, Michael

    2013-04-01

    The personal automobile is a surprisingly efficient device, but its place in a sustainable transportation future hinges on its ability use a sustainable fuel. While electricity is widely expected to be such a ``fuel,'' the viability of electric vehicles rests on the validity of three assumptions. First, that the emissions from generation will be significantly lower than those from competing chemical fuels whether `renewable' or fossil. Second, that advances in battery technology will deliver adequate range and durability at an affordable cost. Third, that most customers will accept any functional limitations intrinsic to electrochemical energy storage. While the first two are subjects of active research and vigorous policy debate, the third is treated virtually as a given. Popular statements to the effect that ``because 70% of all daily travel is accomplished in less than 100 miles, mass deployment of 100 mile EVs will electrify 70% of all travel'' are based on collections of one-day travel reports such as the National Household Travel Survey, and so effectively ignore the complexities of individual needs. We have analyzed the day-to-day variations of individual vehicle usage in multiple regions and draw very different conclusions. Most significant is that limited EV range results in a level of inconvenience that is likely to be unacceptable to the vast majority of vehicle owners, and for those who would accept that inconvenience, battery costs must be absurdly low to achieve any economic payback. In contrast, the plug-in hybrid (PHEV) does not suffer range limitations and delivers economic payback for most users at realistic battery costs. More importantly, these findings appear to be universal in developed nations, with labor market population density being a powerful predictor of personal vehicle usage. This ``scalable city'' hypothesis may prove to a powerful predictor of the evolution of transportation in the large cities of the developing world.

  4. The accuracy of pain and fatigue items across different reporting periods

    PubMed Central

    Broderick, Joan E.; Schwartz, Joseph E.; Vikingstad, Gregory; Pribbernow, Michelle; Grossman, Steven; Stone, Arthur A.

    2008-01-01

    The length of the reporting period specified for items assessing pain and fatigue varies among instruments. How the length of recall impacts the accuracy of symptom reporting is largely unknown. This study investigated the accuracy of ratings for reporting periods ranging from 1 day to 28 days for several items from widely used pain and fatigue measures (SF36v2, Brief Pain Inventory, McGill Pain Questionnaire, Brief Fatigue Inventory). Patients from a community rheumatology practice (N=83) completed momentary pain and fatigue items on average 5.4 times per day for a month using an electronic diary. Averaged momentary ratings formed the basis for comparison with recall ratings interspersed throughout the month referencing 1-day, 3-day, 7-day, and 28-day periods. As found in previous research, recall ratings were consistently inflated relative to averaged momentary ratings. Across most items, 1-day recall corresponded well to the averaged momentary assessments for the day. Several, but not all, items demonstrated substantial correlations across the different reporting periods. An additional 7 day-by-day recall task suggested that patients have increasing difficulty actually remembering symptom levels beyond the past several days. These data were collected while patients were receiving usual care and may not generalize to conditions where new interventions are being introduced and outcomes evaluated. Reporting periods can influence the accuracy of retrospective symptom reports and should be a consideration in study design. PMID:18455312

  5. 40 CFR 61.65 - Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... basis and analyzes the samples with gas chromatography or, if the owner or operator assumes that all... concentration of vinyl chloride in the exhaust gases does not exceed 10 ppm (average for 3-hour period), or... chloride in the exhaust gases does not exceed 10 ppm (average for 3-hour period), or equivalent as provided...

  6. 40 CFR 80.405 - What penalties apply under this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subject to civil penalties as specified in section 205 of the Clean Air Act for every day of each such... violation for each and every day in the averaging period. Any person liable under § 80.395(b) for a failure... correction, is subject to a separate day of violation for each and every day in the averaging period in which...

  7. What Is Climate Change?

    ERIC Educational Resources Information Center

    Beswick, Adele

    2007-01-01

    Weather consists of those meteorological events, such as rain, wind and sunshine, which can change day-by-day or even hour-by-hour. Climate is the average of all these events, taken over a period of time. The climate varies over different parts of the world. Climate is usually defined as the average of the weather over a 30-year period. It is when…

  8. Large rivers of the United States

    USGS Publications Warehouse

    Iseri, Kathleen T.; Langbein, Walter Basil

    1974-01-01

    Information on the flow of the 28 largest rivers in the United States is presented for the base periods 1931-60 and 1941-70. Drainage area, stream length, source, and mouth are included. Table 1 shows the average discharge at downstream gaging stations. Table 2 lists large rivers in order of average discharge at the mouth, based on the period 1941-70.

  9. Ground-motion prediction equations for the average horizontal component of PGA, PGV, and 5%-damped PSA at spectral periods between 0.01 s and 10.0 s

    USGS Publications Warehouse

    Boore, D.M.; Atkinson, G.M.

    2008-01-01

    This paper contains ground-motion prediction equations (GMPEs) for average horizontal-component ground motions as a function of earthquake magnitude, distance from source to site, local average shear-wave velocity, and fault type. Our equations are for peak ground acceleration (PGA), peak ground velocity (PGV), and 5%-damped pseudo-absolute-acceleration spectra (PSA) at periods between 0.01 s and 10 s. They were derived by empirical regression of an extensive strong-motion database compiled by the 'PEER NGA' (Pacific Earthquake Engineering Research Center's Next Generation Attenuation) project. For periods less than 1 s, the analysis used 1,574 records from 58 mainshocks in the distance range from 0 km to 400 km (the number of available data decreased as period increased). The primary predictor variables are moment magnitude (M), closest horizontal distance to the surface projection of the fault plane (RJB), and the time-averaged shear-wave velocity from the surface to 30 m (VS30). The equations are applicable for M=5-8, RJB<200 km, and VS30= 180-1300 m/s. ?? 2008, Earthquake Engineering Research Institute.

  10. Maximum likelihood estimation for periodic autoregressive moving average models

    USGS Publications Warehouse

    Vecchia, A.V.

    1985-01-01

    A useful class of models for seasonal time series that cannot be filtered or standardized to achieve second-order stationarity is that of periodic autoregressive moving average (PARMA) models, which are extensions of ARMA models that allow periodic (seasonal) parameters. An approximation to the exact likelihood for Gaussian PARMA processes is developed, and a straightforward algorithm for its maximization is presented. The algorithm is tested on several periodic ARMA(1, 1) models through simulation studies and is compared to moment estimation via the seasonal Yule-Walker equations. Applicability of the technique is demonstrated through an analysis of a seasonal stream-flow series from the Rio Caroni River in Venezuela.

  11. 26 CFR 1.410(b)-5 - Average benefit percentage test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... percentage of a group of employees for a testing period is the average of the employee benefit percentages... different definitions of average annual compensation; (C) Use of different testing ages; (D) Use of...) Restriction on use of separate testing group determination method. A plan does not satisfy the average benefit...

  12. Glacier mass budget measurements by hydrologic means

    USGS Publications Warehouse

    Tangborn, Wendell V.

    1966-01-01

    Ice storage changes for the South Cascade Glacier drainage basin were determined for the 1957–1964 period using basin runoff and precipitation measurements. Measurements indicate that evaporation and condensation are negligible compared with the large runoff and precipitation values. Runoff, measured by a stream discharge station, averaged 4.04 m/yr; precipitation, determined by snow accumulation measurements at a central point on the glacier and by storage gages, averaged 3.82 m/yr, resulting in a basin net loss of about 0.22 m/yr. During the same period, South Cascade Glacier net budgets were determined by ablation stakes, snow density-depth profiles, and maps. The average glacier net budget for the period was −0.61sol;yr of water. This amount is equivalent to −0.26 m of water when averaged over the drainage basin (43% glacier-covered), which is in fair agreement with the net storage change measured by hydrologic methods. Agreement between the two methods for individual years is slightly less perfect.

  13. Acid rain monitoring in East-Central Florida from 1977 to present

    NASA Technical Reports Server (NTRS)

    Madsen, B. C.; Kheoh, T.; Hinkle, C. R.; Dreschel, T. W.

    1990-01-01

    Rainfall has been collected on the University of Central Florida campus and at the Kennedy Space Center over a 12 year period. The chemical composition has been determined and summarized by monthly, annual periods, and for the entire 12 year period at both locations. The weighted average pH at each site is 4.58; however, annual weighted average pH has been equal to or above the 12 year average during six of the past eight years. Nitrate concentrations have increased slightly during recent years while excess sulfate concentrations have remained below the 12 year weighted average during six of the past seven years. Stepwise regression suggests that sulfate, nitrate, ammonium ion and calcium play major roles in the description of rainwater acidity. Annual acid deposition and annual rainfall have varied from 20 to 50 meg/(m(exp 2) year) and 100 to 180 cm/year, respectively. Sea salt comprises at least 25 percent of the total ionic composition.

  14. The financial cost of hamstring strain injuries in the Australian Football League.

    PubMed

    Hickey, Jack; Shield, Anthony J; Williams, Morgan D; Opar, David A

    2014-04-01

    Hamstring strain injuries (HSIs) have remained the most prevalent injury in the Australian Football League (AFL) over the past 21 regular seasons. The effect of HSIs in sports is often expressed as regular season games missed due to injury. However, the financial cost of athletes missing games due to injury has not been investigated. The aim of this report is to estimate the financial cost of games missed due to HSIs in the AFL. Data were collected using publicly available information from the AFL's injury report and the official AFL annual report for the past 10 competitive AFL seasons. Average athlete salary and injury epidemiology data were used to determine the average yearly financial cost of HSIs for AFL clubs and the average financial cost of a single HSI over this time period. Across the observed period, average yearly financial cost of HSIs per club increased by 71% compared with a 43% increase in average yearly athlete salary. Over the same time period the average financial cost of a single HSI increased by 56% from $A25,603 in 2003 to $A40,021 in 2012, despite little change in the HSI rates during the period. The observed increased financial cost of HSIs was ultimately explained by the failure of teams to decrease HSI rates, but coupled with increases in athlete salaries over the past 10 season. The information presented in this report highlights the financial cost of HSIs and other sporting injuries, raising greater awareness and the need for further funding for research into injury prevention strategies to maximise economical return for investment in athletes.

  15. Carbon dioxide and water exchange rates by a wheat crop in NASA's biomass production chamber: Results from an 86-day study (January to April 1989)

    NASA Technical Reports Server (NTRS)

    Wheeler, R. M.; Sager, J. C.

    1990-01-01

    Gas exchange measurements were taken for a 20 sq m wheat stand grown from seed to harvest in NASA's Biomass Production Chamber. Respiration of the wheat stand caused the CO2 concentrations to rise an average of 440 ppm during the 4-h dark period each day, or 7.2 umol/sq m/sec. Dark period respiration was sensitive to temperature changes and could be increased 70 to 75 percent by raising the temperature from 16 C to 24 C. Stand photosynthesis (measured from the rate of CO2 drawdown immediately after the lights came on each day) peaked at 27 umol/sq m/sec at 25 days after planting and averaged 15 umol/sq m/sec throughout the study. By combining the average light period photosynthesis and average dark period respiration, a net of 860 g or 470 liters of CO2 were fixed per day. Stand photosynthetic rates showed a linear increase with increasing irradiance (750 umol/sq m/sec PPF the highest level tested), with an average light compensation point after day 30 of 190 umol/sq m/sec. Stand photosynthesis decreased slightly when CO2 levels were decreased from 2200 to 800 ppm, but dropped sharply when CO2 was decreased below 700 to 800 ppm. Water production from stand transpiration peaked at 120 L/day near 25 days and averaged about 90 L/day, or 4.5 L/sq m/day throughout the study.

  16. Estimation of spatial patterns of urban air pollution over a 4-week period from repeated 5-min measurements

    NASA Astrophysics Data System (ADS)

    Gillespie, Jonathan; Masey, Nicola; Heal, Mathew R.; Hamilton, Scott; Beverland, Iain J.

    2017-02-01

    Determination of intra-urban spatial variations in air pollutant concentrations for exposure assessment requires substantial time and monitoring equipment. The objective of this study was to establish if short-duration measurements of air pollutants can be used to estimate longer-term pollutant concentrations. We compared 5-min measurements of black carbon (BC) and particle number (PN) concentrations made once per week on 5 occasions, with 4 consecutive 1-week average nitrogen dioxide (NO2) concentrations at 18 locations at a range of distances from busy roads in Glasgow, UK. 5-min BC and PN measurements (averaged over the two 5-min periods at the start and end of a week) explained 40-80%, and 7-64% respectively, of spatial variation in the intervening 1-week NO2 concentrations for individual weeks. Adjustment for variations in background concentrations increased the percentage of explained variation in the bivariate relationship between the full set of NO2 and BC measurements over the 4-week period from 28% to 50% prior to averaging of repeat measurements. The averages of five 5-min BC and PN measurements made over 5 weeks explained 75% and 33% respectively of the variation in average 1-week NO2 concentrations over the same period. The relatively high explained variation observed between BC and NO2 measured on different time scales suggests that, with appropriate steps to correct or average out temporal variations, repeated short-term measurements can be used to provide useful information on longer-term spatial patterns for these traffic-related pollutants.

  17. Kuru

    MedlinePlus

    ... years afterward because the disease has a long incubation period. The incubation period is the time it takes for symptoms ... can lead to malnutrition or starvation. The average incubation period is 10 to 13 years, but incubation ...

  18. [Risk factors for absenteeism due to sick leave in the petroleum industry].

    PubMed

    Oenning, Nágila Soares Xavier; Carvalho, Fernando Martins; Lima, Veronica Maria Cadena

    2014-02-01

    To identify risk factors for absenteeism among workers with sick leave in an oil company. A case-control study (120 cases and 656 controls) nested in a retrospective cohort study following up all employees of an oil company in the North-Northeast of Brazil from 2007 to 2009. The response variable used to represent absenteeism with sick leave was the average incidence of sick leave, defined as the ratio between total sick days and potential working days in the period. Logistic regression techniques were used to investigate the association between average incidence of sick leave > 5.0% over the period and the variables sex, position, age, time at work, shift work, smoking, arterial hypertension, body mass index, physical activity, coronary risk, sleep, glycemia, non-managed diabetes, cardiovascular, digestive, musculoskeletal, neurological and neoplastic diseases, straining body positioning during work, satisfaction at work, relationship with management, and concentrated attention at work. Average incidence of sick leave higher than 5.0% in the cohort period was 15.5%. The logistic model revealed that workers with average incidence of sick leave higher than 5.0% were 2.6 times more likely to be female; 2.0 time more likely to be smokers; 1.8 time more likely to be former smokers; 2.2 times more likely to report abnormal sleep and 10.5 times more likely to report dissatisfaction with their than workers with average incidence of sick leave ≤ 5.0% in the period. In this population, female gender, being a smoker or a former smoker, reporting dissatisfaction with the job and reporting abnormal sleep are good predictors of occupational absenteeism with sick leave. To identify risk factors for absenteeism among workers with sick leave in an oil company. A case-control study (120 cases and 656 controls) nested in a retrospective cohort study following up all employees of an oil company in the North-Northeast of Brazil from 2007 to 2009. The response variable used to represent absenteeism with sick leave was the average incidence of sick leave, defined as the ratio between total sick days and potential working days in the period. Logistic regression techniques were used to investigate the association between average incidence of sick leave > 5.0% over the period and the variables sex, position, age, time at work, shift work, smoking, arterial hypertension, body mass index, physical activity, coronary risk, sleep, glycemia, non-managed diabetes, cardiovascular, digestive, musculoskeletal, neurological and neoplastic diseases, straining body positioning during work, satisfaction at work, relationship with management, and concentrated attention at work. Average incidence of sick leave higher than 5.0% in the cohort period was 15.5%. The logistic model revealed that workers with average incidence of sick leave higher than 5.0% were 2.6 times more likely to be female; 2.0 time more likely to be smokers; 1.8 time more likely to be former smokers; 2.2 times more likely to report abnormal sleep and 10.5 times more likely to report dissatisfaction with their than workers with average incidence of sick leave ≤ 5.0% in the period. In this population, female gender, being a smoker or a former smoker, reporting dissatisfaction with the job and reporting abnormal sleep are good predictors of occupational absenteeism with sick leave.

  19. Stability, precision, and near-24-hour period of the human circadian pacemaker

    NASA Technical Reports Server (NTRS)

    Czeisler, C. A.; Duffy, J. F.; Shanahan, T. L.; Brown, E. N.; Mitchell, J. F.; Rimmer, D. W.; Ronda, J. M.; Silva, E. J.; Allan, J. S.; Emens, J. S.; hide

    1999-01-01

    Regulation of circadian period in humans was thought to differ from that of other species, with the period of the activity rhythm reported to range from 13 to 65 hours (median 25.2 hours) and the period of the body temperature rhythm reported to average 25 hours in adulthood, and to shorten with age. However, those observations were based on studies of humans exposed to light levels sufficient to confound circadian period estimation. Precise estimation of the periods of the endogenous circadian rhythms of melatonin, core body temperature, and cortisol in healthy young and older individuals living in carefully controlled lighting conditions has now revealed that the intrinsic period of the human circadian pacemaker averages 24.18 hours in both age groups, with a tight distribution consistent with other species. These findings have important implications for understanding the pathophysiology of disrupted sleep in older people.

  20. Bioaerosols study in central Taiwan during summer season.

    PubMed

    Wang, Chun-Chin; Fang, Guor-Cheng; Lee, LienYao

    2007-04-01

    Suspended particles, of which bioaerosols are one type, constitute one of the main reasons to cause severe air quality in Taiwan. Bioaerosols include allergens such as fungi, bacteria, actinomycetes, arthropods and protozoa, as well as microbial products such as mycotoxins, endotoxins and glucans. When allergens and microbial products are suspended in the air, local air quality will be influenced severely. In addition, when the particle size is small enough to pass through the respiratory tract entering the human body, the health of the local population is also threatened. Therefore, the purpose of this study attempted to understand the concentration and types of bacteria during summer period at four sampling sites in Taichung city, central Taiwan. The results indicated that total average bacterial concentration by using R2A medium incubated for 48 h were 7.3 x 10(2) and 1.2 x 10(3) cfu/m3 for Chung-Ming elementary sampling site during daytime and night-time period of summer season. In addition, total average bacterial concentration by using R2A medium incubated for 48 h were 2.2 x 10(3) and 2.5 x 10(3) cfu/m3 for Taichung refuse incineration plant sampling site during daytime and night-time period of summer season. As for Rice Field sampling site during daytime and night-time period of summer season, the results also reflected that the total average bacterial concentration by using R2A medium incubated for 48 h were 3.4 x 10(3) and 3.5 x 10(3) cfu/m3. Finally, total average bacterial concentration by using R2A medium incubated for 48 h were 1.6 x 10(3) and 1.9 x 10(3) cfu/m3 for Central Taiwan Science Park sampling site during daytime and night-time period of summer season. Moreover, the average bacterial concentration increased as the incubated time in a growth medium increased for particle sizes of 0.65-1.1, 1.1-2.1, 2.1-3.3, 3.3-4.7 and 4.7-7.0 microm. The total average bacterial concentration has no significant difference for day and night sampling period at any sampling site for the expression of bacterial concentration in term of order. The high average bacterial concentration was found in the particle size of 0.53-0.71 mm (average bioaerosol size was in the range of 2.1-4.7 microm) for each sampling site. Besides, there were exceeded 20 kinds of bacteria for each sampling site and the bacterial shape were rod, coccus and filamentous.

Top