Sample records for average respirable dust

  1. 30 CFR 71.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... respirable dust in the mine atmosphere of the active workings contains more than 5 percent quartz, the operator shall continuously maintain the average concentration of respirable dust in the mine atmosphere... 20%, Therefore, the average concentration of respirable dust in the mine atmosphere associated with...

  2. 30 CFR 71.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... respirable dust in the mine atmosphere of the active workings contains more than 5 percent quartz, the operator shall continuously maintain the average concentration of respirable dust in the mine atmosphere... 20%, Therefore, the average concentration of respirable dust in the mine atmosphere associated with...

  3. 30 CFR 71.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... respirable dust in the mine atmosphere of the active workings contains more than 5 percent quartz, the operator shall continuously maintain the average concentration of respirable dust in the mine atmosphere... 20%, Therefore, the average concentration of respirable dust in the mine atmosphere associated with...

  4. 30 CFR 71.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... respirable dust in the mine atmosphere of the active workings contains more than 5 percent quartz, the operator shall continuously maintain the average concentration of respirable dust in the mine atmosphere... 20%, Therefore, the average concentration of respirable dust in the mine atmosphere associated with...

  5. 30 CFR 71.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... respirable dust in the mine atmosphere of the active workings contains more than 5 percent quartz, the operator shall continuously maintain the average concentration of respirable dust in the mine atmosphere... 20%, Therefore, the average concentration of respirable dust in the mine atmosphere associated with...

  6. 30 CFR 90.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quartz is present. When the respirable dust in the mine atmosphere of the active workings to which a Part... average concentration of respirable dust in the mine atmosphere during each shift to which a Part 90 miner...%. Therefore, the average concentration of respirable dust in the mine atmosphere associated with that Part 90...

  7. 30 CFR 90.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quartz is present. When the respirable dust in the mine atmosphere of the active workings to which a Part... average concentration of respirable dust in the mine atmosphere during each shift to which a Part 90 miner...%. Therefore, the average concentration of respirable dust in the mine atmosphere associated with that Part 90...

  8. 30 CFR 90.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quartz is present. When the respirable dust in the mine atmosphere of the active workings to which a Part... average concentration of respirable dust in the mine atmosphere during each shift to which a Part 90 miner...%. Therefore, the average concentration of respirable dust in the mine atmosphere associated with that Part 90...

  9. 30 CFR 90.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quartz is present. When the respirable dust in the mine atmosphere of the active workings to which a Part... average concentration of respirable dust in the mine atmosphere during each shift to which a Part 90 miner...%. Therefore, the average concentration of respirable dust in the mine atmosphere associated with that Part 90...

  10. 30 CFR 90.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quartz is present. When the respirable dust in the mine atmosphere of the active workings to which a Part... average concentration of respirable dust in the mine atmosphere during each shift to which a Part 90 miner...%. Therefore, the average concentration of respirable dust in the mine atmosphere associated with that Part 90...

  11. 30 CFR 70.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Respirable dust standard when quartz is present. When the respirable dust in the mine atmosphere of the... concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active... average concentration of respirable dust in the mine atmosphere associated with that mechanized mining...

  12. 30 CFR 70.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Respirable dust standard when quartz is present. When the respirable dust in the mine atmosphere of the... concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active... average concentration of respirable dust in the mine atmosphere associated with that mechanized mining...

  13. 30 CFR 70.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Respirable dust standard when quartz is present. When the respirable dust in the mine atmosphere of the... concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active... average concentration of respirable dust in the mine atmosphere associated with that mechanized mining...

  14. 30 CFR 70.101 - Respirable dust standard when quartz is present.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Respirable dust standard when quartz is present. When the respirable dust in the mine atmosphere of the... concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active... average concentration of respirable dust in the mine atmosphere associated with that mechanized mining...

  15. An Evaluation of an Aftermarket Local Exhaust Ventilation Device for Suppressing Respirable Dust and Respirable Crystalline Silica Dust from Powered Saws

    PubMed Central

    Garcia, Alberto; Jones, Erica; Echt, Alan S.; Hall, Ronald M.

    2015-01-01

    The objective of this study was to quantify the respirable dust and respirable silica exposures of roofing workers using an electric powered circular saw with an aftermarket local exhaust ventilation attachment to cut concrete roofing tiles. The study was conducted to determine whether the local exhaust ventilation attachment was able to control respirable dust and respirable silica exposure below occupational exposure limits. Time-integrated filter samples and direct reading respirable dust concentrations were evaluated. The local exhaust ventilation consisted of a shroud attached to the cutting plane of the saw; the shroud was then connected to a small electric axial fan, which is intended to collect dust at the point of generation. All sampling was conducted with the control in use. Roofers are defined as those individuals who solely lay tiles. Cutters/roofers are defined as those workers who operate the powered saw to cut tiles and also lay tiles. Respirable dust from this evaluation ranged from 0.13 to 6.59 milligrams per cubic meter (mg/m3) with a geometric mean of 0.38 mg/m3 for roofers and from 0.45 to 3.82 mg/m3 with a geometric mean of 1.84 mg/m3 for cutters/roofers. Cutters/roofers usually handle areas close to crevices, edges, or tips of the roof whereas roofers handle areas where complete tiles can be placed. The respirable dust exposures for all cutters/roofers indicated concentrations exceeding the Occupational Safety and Health Administration’s (OSHA) permissible exposure limit (PEL) for respirable dust containing silica; it was also exceeded for some of the roofers. The respirable silica concentrations ranged from 0.04 to 0.15 mg/m3 with an average of 0.09 mg/m3 for roofers, and from 0.13 to 1.21 mg/m3 with an average of 0.48 mg/m3 for cutters/roofers. As with respirable dust, the respirable silica exposures to cutters/roofers were higher than the exposures for roofers. PMID:25148513

  16. Characterizing Dust from Cutting Corian®, a Solid-Surface Composite Material, in a Laboratory Testing System.

    PubMed

    Qi, Chaolong; Echt, Alan; Murata, Taichi K

    2016-06-01

    We conducted a laboratory test to characterize dust from cutting Corian(®), a solid-surface composite material, with a circular saw. Air samples were collected using filters and direct-reading instruments in an automatic laboratory testing system. The average mass concentrations of the total and respirable dusts from the filter samples were 4.78±0.01 and 1.52±0.01mg cm(-3), respectively, suggesting about 31.8% mass of the airborne dust from cutting Corian(®) is respirable. Analysis of the metal elements on the filter samples reveals that aluminum hydroxide is likely the dominant component of the airborne dust from cutting Corian(®), with the total airborne and respirable dusts containing 86.0±6.6 and 82.2±4.1% aluminum hydroxide, respectively. The results from the direct-reading instruments confirm that the airborne dust generated from cutting Corian(®) were mainly from the cutting process with very few particles released from the running circular saw alone. The number-based size distribution of the dusts from cutting Corian(®) had a peak for fine particles at 1.05 µm with an average total concentration of 871.9 particles cm(-3), and another peak for ultrafine particles at 11.8nm with an average total concentration of 1.19×10(6) particles cm(-3) The small size and high concentration of the ultrafine particles suggest additional investigation is needed to study their chemical composition and possible contribution to pulmonary effect. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.

  17. Characterizing Dust from Cutting Corian®, a Solid-Surface Composite Material, in a Laboratory Testing System

    PubMed Central

    Qi, Chaolong; Echt, Alan; Murata, Taichi K

    2016-01-01

    We conducted a laboratory test to characterize dust from cutting Corian®, a solid-surface composite material, with a circular saw. Air samples were collected using filters and direct-reading instruments in an automatic laboratory testing system. The average mass concentrations of the total and respirable dusts from the filter samples were 4.78±0.01 and 1.52±0.01 mg cm−3, respectively, suggesting about 31.8% mass of the airborne dust from cutting Corian® is respirable. Analysis of the metal elements on the filter samples reveals that aluminum hydroxide is likely the dominant component of the airborne dust from cutting Corian®, with the total airborne and respirable dusts containing 86.0%±6.6% and 82.2%±4.1% aluminum hydroxide, respectively. The results from the direct-reading instruments confirm that the airborne dust generated from cutting Corian® were mainly from the cutting process with very few particles released from the running circular saw alone. The number-based size distribution of the dusts from cutting Corian® had a peak for fine particles at 1.05 µm with an average total concentration of 871.9 particles cm−3, and another peak for ultrafine particles at 11.8 nm with an average total concentration of 1.19×106 particles cm−3. The small size and high concentration of the ultrafine particles suggest additional investigation is needed to study their chemical composition and possible contribution to pulmonary effect. PMID:26872962

  18. Determination of exposure to respirable quartz in the stone crushing units at Azendarian-West of Iran.

    PubMed

    Bahrami, Abdul Rahman; Golbabai, Faridah; Mahjub, Hossien; Qorbani, Farshid; Aliabadi, Mohsan; Barqi, Mohamadali

    2008-08-01

    The purpose of this study is to describe the personal exposure to respirable dust and quartz and in stone crushing units located at west of Iran. A size of 40 personal samples and 40 stationary samples were obtained and analysis was done by X-ray diffraction (XRD). The results of personal sampling were shown the concentrations of respirable dust exposure level in workers of process, hopper and drivers were 1.90, 2.22, 1.41 times greater than Occupational Safety and Health Administration permissible exposure limit (OSHA PEL). The average value of total dust and respirable dust emission from stationary sources was 9.46 mg/m(3), 1.24 mg/m(3) respectively, showing that 13.8 % of total dust is respirable. The efficiency of local exhaust ventilation (LEV) to control of particles inside of industrial units was greater than 99%. It is concluded from this research the particulate generated from stone crushing activities contain a significant amount of respirable particle. The amount of free silica in stone quartz is 85 to 97 percent that emission of particles effect to health workers. LEV has important effect in the removal of silica particles in stone crushing units. The worker of hoppers still exposed to silica more than standard limits.

  19. Change of exposure response over time and long-term risk of silicosis among a cohort of Chinese pottery workers.

    PubMed

    Sun, Yi; Bochmann, Frank; Morfeld, Peter; Ulm, Kurt; Liu, Yuewei; Wang, Heijiao; Yang, Lei; Chen, Weihong

    2011-07-01

    An analysis was conducted on a cohort of Chinese pottery workers to estimate the exposure-response relationship between respirable crystalline silica dust exposure and the incidence of radiographically diagnosed silicosis, and to estimate the long-term risk of developing silicosis until the age of 65. The cohort comprised 3,250 employees with a median follow-up duration of around 37 years. Incident cases of silicosis were identified via silicosis registries (Chinese X-ray stage I, similar to International Labor Organisation classification scheme profusion category 1/1). Individual exposure to respirable crystalline silica dust was estimated based on over 100,000 historical dust measurements. The association between dust exposure, incidence and long-time risk of silicosis was quantified by Poisson regression analysis adjusted for age and smoking. The risk of silicosis depended not only on the cumulative respirable crystalline silica dust exposures, but also on the time-dependent respirable crystalline silica dust exposure pattern (long-term average concentration, highest annual concentration ever experienced and time since first exposure). A long-term "excess" risk of silicosis of approximately 1.5/1,000 was estimated among workers with all annual respirable crystalline silica dust concentration estimates less than 0.1 mg/m(3), using the German measurement strategy. This study indicates the importance of proper consideration of exposure information in risk quantification in epidemiological studies.

  20. Silica exposure to excavation workers during the excavation of a low level radiological waste pit and tritium disposal shafts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, K.M.

    1995-01-01

    This study evaluated the task-length average (TLA) respirable dust and respirable silica airborne concentrations to which construction workers excavating volcanic tuff at Los Alamos National Laboratory (LANL) were exposed. These workers were excavating a low level radiological waste disposal pit of final dimensions 720 feet long, 132 feet wide and 60 feet deep. The objectives of this study were as follows: (1) evaluate exposures; (2) determine if the type of machinery used affects the respirable dust concentration in the breathing zone of the worker; (3) evaluate the efficacy of wetting the pit to reduce the respirable dust exposure; and (4)more » determine if exposure increases with increasing depth of pit due to the walls of the pit blocking the cross wind ventilation.« less

  1. 76 FR 25277 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-04

    ... 1219-AB64 Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust... to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. This extension gives... Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. In response...

  2. Respiratory symptoms associated with low level sulphur dioxide exposure in silicon carbide production workers.

    PubMed Central

    Osterman, J W; Greaves, I A; Smith, T J; Hammond, S K; Robins, J M; Thériault, G

    1989-01-01

    Relations between pulmonary symptoms and exposure to respirable dust and sulphur dioxide (SO2) were evaluated for 145 silicon carbide (SiC) production workers with an average of 13.9 (range 3-41) years of experience in this industry. Eight hour time weighted average exposures to SO2 were 1.5 ppm or less with momentary peaks up to 4 ppm. Cumulative SO2 exposure averaged 1.94 (range 0.02-19.5) ppm-years. Low level respirable dust exposures also occurred (0.63 +/- 0.26 mg/m3). After adjusting for age and current smoking status in multiple logistic regression models, highly significant, positive, dose dependent relations were found between cumulative and average exposure to SO2, and symptoms of usual and chronic phlegm, usual and chronic wheeze, and mild exertional dyspnoea. Mild and moderate dyspnoea were also associated with most recent exposure to SO2. Cough was not associated with SO2. No pulmonary symptoms were associated with exposure to respirable dust nor were any symptoms attributable to an interaction between dust and SO2. Cigarette smoking was strongly associated with cough, phlegm, and wheezing, but not dyspnoea. A greater than additive (synergistic) effect between smoking and exposure to SO2 was present for most symptoms. These findings suggest that long term, variable exposure to SO2 at 1.5 ppm or less was associated with significantly raised rates of phlegm, wheezing, and mild dyspnoea in SiC production workers, and that current threshold limits for SO2 may not adequately protect workers in this industry. PMID:2789966

  3. Development and evaluation of a semi-empirical two-zone dust exposure model for a dusty construction trade.

    PubMed

    Jones, Rachael M; Simmons, Catherine; Boelter, Fred

    2011-06-01

    Drywall finishing is a dusty construction activity. We describe a mathematical model that predicts the time-weighted average concentration of respirable and total dusts in the personal breathing zone of the sander, and in the area surrounding joint compound sanding activities. The model represents spatial variation in dust concentrations using two-zones, and temporal variation using an exponential function. Interzone flux and the relationships between respirable and total dusts are described using empirical factors. For model evaluation, we measured dust concentrations in two field studies, including three workers from a commercial contracting crew, and one unskilled worker. Data from the field studies confirm that the model assumptions and parameterization are reasonable and thus validate the modeling approach. Predicted dust C(twa) were in concordance with measured values for the contracting crew, but under estimated measured values for the unskilled worker. Further characterization of skill-related exposure factors is indicated.

  4. 75 FR 69617 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ... 1219-AB64 Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust... hearings on the proposed rule addressing Lowering Miners' Exposure to Respirable Coal Mine Dust, Including... miners' exposure to respirable coal mine dust by revising the Agency's existing standards on miners...

  5. 76 FR 2617 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-14

    ... 1219-AB64 Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust... comment period on the proposed rule addressing Lowering Miners' Exposure to Respirable Coal Mine Dust...), MSHA published a proposed rule, Lowering Miners' Exposure to Respirable Coal Mine Dust, Including...

  6. Respirable dust measured downwind during rock dust application.

    PubMed

    Harris, M L; Organiscak, J; Klima, S; Perera, I E

    2017-05-01

    The Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health (NIOSH) conducted underground evaluations in an attempt to quantify respirable rock dust generation when using untreated rock dust and rock dust treated with an anticaking additive. Using personal dust monitors, these evaluations measured respirable rock dust levels arising from a flinger-type application of rock dust on rib and roof surfaces. Rock dust with a majority of the respirable component removed was also applied in NIOSH's Bruceton Experimental Mine using a bantam duster. The respirable dust measurements obtained downwind from both of these tests are presented and discussed. This testing did not measure miners' exposure to respirable coal mine dust under acceptable mining practices, but indicates the need for effective continuous administrative controls to be exercised when rock dusting to minimize the measured amount of rock dust in the sampling device.

  7. A survey of size-fractionated dust levels in the U.S. wood processing industry.

    PubMed

    Kalliny, Medhat I; Brisolara, Joseph A; Glindmeyer, Henry; Rando, Roy

    2008-08-01

    A survey of size-fractionated dust exposure was carried out in 10 wood processing plants across the United States as part of a 5-year longitudinal respiratory health study. The facilities included a sawmill, plywood assembly plants, secondary wood milling operations, and factories producing finished wood products such as wood furniture and cabinets. Size-fractionated dust exposures were determined using the RespiCon Personal Particle Sampler. There were 2430 valid sets of respirable, thoracic, and inhalable dust samples collected. Overall, geometric mean (geometric standard deviation) exposure levels were found to be 1.44 (2.67), 0.35 (2.65), and 0.18 (2.54) mg/m, for the inhalable, thoracic, and respirable fractions, respectively. Averaged across all samples, the respirable fraction accounted for 16.7% of the inhalable dust mass, whereas the corresponding figure for thoracic fraction as a percentage of the inhalable fraction was 28.7%. Exposures in the furniture manufacturing plants were significantly higher than those in sawmill and plywood assembly plants, wood milling plants, and cabinet manufacturing plants, whereas the sawmill and plywood assembly plants exhibited significantly lower dust levels than the other industry segments. Among work activities, cleaning with compressed air and sanding processes produced the highest size-fractionated dust exposures, whereas forklift drivers demonstrated the lowest respirable and inhalable dust fractions and shipping processes produced the lowest thoracic dust fraction. Other common work activities such as sawing, milling, and clamping exhibited intermediate exposure levels, but there were significant differences in relative ranking of these across the various industry segments. Processing of hardwood and mixed woods generally were associated with higher exposures than were softwood and plywood, although these results were confounded with industry segment also.

  8. Dust in the underground railway tunnels of an Italian town.

    PubMed

    Ripanucci, G; Grana, M; Vicentini, L; Magrini, A; Bergamaschi, A

    2006-01-01

    This article assesses hazards associated with exposure to dust in tunnels and platforms of the A and B lines of Rome's underground railway and provides an informed opinion on the risks to workers and the travelling public of exposure to tunnel dust. The study focused on the analysis and measurement of dust granulometric classes PM10, respirable fraction, respirable combustible dust, and the organic, metallic, siliceous, and fibrous components. Comparing the measurement values from the tunnels and platforms with those found at the entrances to the underground railway stations, it emerges that dust concentration in the tunnels and platforms is three times higher, with a maximum PM10 value of 479 microg/m3. Averaged over 24 hours, in relation to the above ground levels, drivers and station staff are exposed to an additional value of 11 microg/m3 and 10 microg/m3, respectively. If commuters were to remain in the trains or on the station platforms, the 24-hour average exposure would increase by 3 microg/m3. Iron and silica were the major components found in the dust. The use of silica sand in the emergency braking system of the carriages is capable of causing a dispersion of quartz in the air in percentages varying from 5% to 14%. Methods are suggested in this article for the reduction of dust dispersion.

  9. Grain elevator workers show work-related pulmonary function changes and dose-effect relationships with dust exposure.

    PubMed Central

    Corey, P; Hutcheon, M; Broder, I; Mintz, S

    1982-01-01

    The purpose of this study was to determine whether grain handlers underwent work-related changes in their pulmonary function and, if so, to examine the dose-effect relationships with dust exposure. The pulmonary function of grain handlers was measured at the beginning and end of work shifts over a period of one week, during which their exposure to dust was measured daily. The results showed changes indicative of a within-day obstructive change, in addition to a small restrictive defect occurring over the course of a week. Civic outside labourers who were examined as a control group showed a similar within-week obstructive change without any associated restriction of lung volume. The data on the grain handlers were also used to examine the dose-effect relationships of dust exposure, both on baseline pulmonary function and on within-day changes in these measurements. The baseline flow rates of workers who did not wear a mask were found to vary inversely with their average exposure to respirable dust. In addition, the flow rates underwent a within-day decrease that varied directly with their corresponding exposure to respirable dust and was unrelated to mask wearing. The median of the slopes for this relationship indicated that 50% of the subjects had a decrease of at least 923 ml/s in the value of their Vmax50%VC for each 1 mg/m3 increase in the concentration of respirable dust. Non-respirable dust did not have a measurable effect either on the baseline or the within-day changes in pulmonary function. The acute changes were unaffected by age, duration of employment, or extent of smoking. PMID:7138793

  10. 77 FR 59667 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Respirable...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-28

    ... for OMB Review; Comment Request; Respirable Coal Mine Dust Sampling ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Respirable Coal Mine Dust Sampling,'' to the Office of... operator to protect miners from exposure to excessive dust levels. The respirable coal mine dust sampling...

  11. The evaluation and quantification of respirable coal and silica dust concentrations: a task-based approach.

    PubMed

    Grové, T; Van Dyk, T; Franken, A; Du Plessis, J

    2014-01-01

    Silicosis and coal worker's pneumoconiosis are serious occupational respiratory diseases associated with the coal mining industry and the inhalation of respirable dusts containing crystalline silica. The purpose of this study (funded by the Mine Health and Safety Council of South Africa) was to evaluate the individual contributions of underground coal mining tasks to the respirable dust and respirable silica dust concentrations in an underground section by sampling the respirable dust concentrations at the intake and return of each task. The identified tasks were continuous miner (CM) cutting, construction, transfer of coal, tipping, and roof bolting. The respirable dust-generating hierarchy of the tasks from highest to lowest was: transfer of coal > CM right cutting > CM left cutting > CM face cutting > construction > roof bolting > tipping; and for respirable silica dust: CM left cutting > construction > transfer of coal > CM right cutting. Personal exposure levels were determined by sampling the exposures of workers performing tasks in the section. Respirable dust concentrations and low concentrations of respirable silica dust were found at the intake air side of the section, indicating that air entering the section is already contaminated. The hierarchy for personal respirable dust exposures was as follows, from highest to lowest: CM operator > cable handler > miner > roof bolt operator > shuttle car operator, and for respirable silica dust: shuttle car operator > CM operator > cable handler > roof bolt operator > miner. Dust control methods to lower exposures should include revision of the position of workers with regard to the task performed, positioning of the tasks with regard to the CM cutting, and proper use of the line curtains to direct ventilation appropriately. The correct use of respiratory protection should also be encouraged.

  12. Effects of MERV 16 filters and routine work practices on enclosed cabs for reducing respirable dust and DPM exposures in an underground limestone mine

    PubMed Central

    Noll, J.D.; Cecala, A.B.; J.A.Organiscak; Rider, J.P.

    2015-01-01

    An effective technique to minimize miners’ respirable dust and diesel exposure on mobile mining equipment is to place mine operators in enclosed cabs with designed filtration and pressurization systems. Many factors affect the performance of these enclosed cab systems, and one of the most significant factors is the effectiveness of the filtration system. High-efficiency particulate air (HEPA)-type filters are typically used because they are highly efficient at capturing all types and sizes of particles, including those in the submicron range such as diesel particulate matter (DPM). However, in laboratory tests, minimum efficiency reporting value (MERV) 16 filters have proven to be highly efficient for capturing DPM and respirable dust. Also, MERV 16 filters can be less restrictive to cab airflow and less expensive than HEPA filters. To verify their effectiveness in the field, MERV 16 filters were used in the enclosed cab filtration system on a face drill and roof bolting mining machine and tested at an underground limestone mine. Test results showed that DPM and respirable dust concentrations were reduced by more than 90% when the cabs were properly sealed. However, when the cab door was opened periodically throughout the shift, the reduction efficiency of the MERV 16 filters was reduced to 80% on average. PMID:26236044

  13. High exposure to respirable dust and quartz in a labour-intensive coal mine in Tanzania.

    PubMed

    Mamuya, Simon H D; Bråtveit, Magne; Mwaiselage, Julius; Mashalla, Yohana J S; Moen, Bente E

    2006-03-01

    Labour-intensive mines are numerous in several developing countries, but dust exposure in such mines has not been adequately characterized. The aim of this study was to identify and quantify the determinants of respirable dust and quartz exposure among underground coal mine workers in Tanzania. Personal respirable dust samples (n = 134) were collected from 90 underground workers in June-August 2003 and July-August 2004. The development team had higher exposure to respirable dust and quartz (geometric means 1.80 and 0.073 mg m(-3), respectively) than the mining team (0.47 and 0.013 mg m(-3)), the underground transport team (0.14 and 0.006 mg m(-3)) and the underground maintenance team (0.58 and 0.016 mg m(-3)). The percentages of samples above the threshold limit values (TLVs) of 0.9 mg m(-3) for respirable bituminous coal dust and 0.05 mg m(-3) for respirable quartz, respectively, were higher in the development team (55 and 47%) than in the mining team (20 and 9%). No sample for the underground transport team exceeded the TLV. Drilling in the development was the work task associated with the highest exposure to respirable dust and quartz (17.37 and 0.611 mg m(-3), respectively). Exposure models were constructed using multiple regression model analysis, with log-transformed data on either respirable dust or quartz as the dependent variable and tasks performed as the independent variables. The models for the development section showed that blasting and pneumatic drilling times were major determinants of respirable dust and quartz, explaining 45.2 and 40.7% of the variance, respectively. In the mining team, only blasting significantly determined respirable dust. Immediate actions for improvements are suggested to include implementing effective dust control together with improved training and education programmes for the workers. Dust and quartz in this underground mine should be controlled by giving priority to workers performing drilling and blasting in the development sections of the mine.

  14. Respirable dust and respirable silica exposure in Ontario gold mines.

    PubMed

    Verma, Dave K; Rajhans, Gyan S; Malik, Om P; des Tombe, Karen

    2014-01-01

    A comprehensive survey of respirable dust and respirable silica in Ontario gold mines was conducted by the Ontario Ministry of Labor during 1978-1979. The aim was to assess the feasibility of introducing gravimetric sampling to replace the assessment method which used konimeters, a device which gave results in terms of number of particles per cubic centimeter (ppcc) of air. The study involved both laboratory and field assessments. The field assessment involved measurement of airborne respirable dust and respirable silica at all eight operating gold mines of the time. This article describes the details of the field assessment. A total of 288 long-term (7-8 hr) personal respirable dust air samples were collected from seven occupational categories in eight gold mines. The respirable silica (α-quartz) was determined by x-ray diffraction method. The results show that during 1978-1979, the industry wide mean respirable dust was about 1 mg/m(3), and the mean respirable silica was 0.08 mg/m(3.)The mean% silica in respirable dust was 7.5%. The data set would be useful in future epidemiological and health studies, as well as in assessment of workers' compensation claims for occupational diseases such as silicosis, chronic obstructive pulmonary disease (COPD), and autoimmune diseases such as renal disease and rheumatoid arthritis.

  15. Experimental study on effects of drilling parameters on respirable dust production during roof bolting operations.

    PubMed

    Jiang, Hua; Luo, Yi; McQuerrey, Joe

    2018-02-01

    Underground coalmine roof bolting operators exhibit a continued risk for overexposure to airborne levels of respirable coal and crystalline silica dust from the roof drilling operation. Inhaling these dusts can cause coal worker's pneumoconiosis and silicosis. This research explores the effect of drilling control parameters, specifically drilling bite depth, on the reduction of respirable dust generated during the drilling process. Laboratory drilling experiments were conducted and results demonstrated the feasibility of this dust control approach. Both the weight and size distribution of the dust particles collected from drilling tests with different bite depths were analyzed. The results showed that the amount of total inhalable and respirable dust was inversely proportional to the drilling bite depth. Therefore, control of the drilling process to achieve proper high-bite depth for the rock can be an important approach to reducing the generation of harmful dust. Different from conventional passive engineering controls, such as mist drilling and ventilation approaches, this approach is proactive and can cut down the generation of respirable dust from the source. These findings can be used to develop an integrated drilling control algorithm to achieve the best drilling efficiency as well as reducing respirable dust and noise.

  16. An evaluation of an aftermarket local exhaust ventilation device for suppressing respirable dust and respirable crystalline silica dust from powered saws.

    PubMed

    Garcia, Alberto; Jones, Erica; Echt, Alan S; Hall, Ronald M

    2014-01-01

    The objective of this study was to quantify the respirable dust and respirable silica exposures of roofing workers using an electric-powered circular saw with an aftermarket local exhaust ventilation attachment to cut concrete roofing tiles. The study was conducted to determine whether the local exhaust ventilation attachment was able to control respirable dust and respirable silica exposure below occupational exposure limits (OELs). Time-integrated filter samples and direct reading respirable dust concentrations were evaluated. The local exhaust ventilation consisted of a shroud attached to the cutting plane of the saw; the shroud was then connected to a small electric axial fan, which is intended to collect dust at the point of generation. All sampling was conducted with the control in use. Roofers are defined as those individuals who only lay tiles. Cutters/roofers are defined as those workers who operate the powered saw to cut tiles and also lay tiles. Respirable dust from this evaluation ranged from 0.13 to 6.59 milligrams per cubic meter (mg/m(3)) with a geometric mean of 0.38 mg/m(3) for roofers and from 0.45 to 3.82 mg/m(3) with a geometric mean of 1.84 mg/m(3) for cutters/roofers. Cutters/roofers usually handle areas close to crevices, edges, or tips of the roof whereas roofers handle areas where complete tiles can be placed. The respirable dust exposures for all cutters/roofers indicated concentrations exceeding the Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) for respirable dust containing silica; it was also exceeded for some of the roofers. The respirable silica concentrations ranged from 0.04 to 0.15 mg/m(3) with a geometric mean of 0.09 mg/m(3) for roofers, and from 0.13 to 1.21 mg/m(3) with a geometric mean of 0.48 mg/m(3) for cutters/roofers. As with respirable dust, the respirable silica exposures for cutters/roofers were higher than the exposures for roofers.

  17. [Assessment of occupational exposure to wood dust in the Polish furniture industry].

    PubMed

    Szewczyńska, Małgorzata; Pośniak, Małgorzata

    2017-02-28

    Occupational exposure to wood dust can be responsible for many different harmful health effects, especially in workers employed in the wood industry. The assessment of wood dust adverse effects to humans, as well as the interpretation of its concentration measurements carried out to assess potential occupational exposure are very difficult. First of all, it is due to possible occurrence of different kind of wood dust in the workplace air, namely wood dust from dozens of species of trees belonging to 2 kinds of botanical gymnosperms and angiosperms, as well as to its different chemical composition. Total dust and respirable wood dust in the workplace air in the furniture industry was determined using the filtration-gravimetric method in accordance with Polish Standards PN-Z-04030-05:1991 and PN-Z-04030-06:1991. Air samples were collected based on the principles of individual dosimetry. Total dust concentrations were 0.84-13.92 mg/m3 and inhalable fraction concentrations, obtained after the conversion of total dust by applying a conversion factor of 1.59, were 1.34-22.13 mg/m3. Respirable fraction concentrations were 0.38-4.04 mg/m3, which makes approx. 25% of the inhalable fraction on average. The highest concentrations occurred in grinding and the lowest during milling processes of materials used in the manufacture of furniture. The results indicate that the share of respirable fraction in the inhalable fraction of wood dust is considerable. Due to the determination of the threshold limit value (TLV) for the inhalable fraction of wood dust, it is necessary to replace the previously used samplers for total dust with samplers that provide quantitative separation of wood dust inhalable fractions in accordance with the convention of this fraction as defined in PN-EN 481:1998. Med Pr 2017;68(1):45-60. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  18. Inflammatory markers and exposure to airborne particles among workers in a Swedish pulp and paper mill.

    PubMed

    Westberg, Håkan; Elihn, Karine; Andersson, Eva; Persson, Bodil; Andersson, Lennart; Bryngelsson, Ing-Liss; Karlsson, Cathe; Sjögren, Bengt

    2016-07-01

    To study the relationship between exposure to airborne particles in a pulp and paper mill and markers of inflammation and coagulation in blood. Personal sampling of inhalable dust was performed for 72 subjects working in a Swedish pulp and paper mill. Stationary measurements were used to study concentrations of total dust, respirable dust, PM10 and PM2.5, the particle surface area and the particle number concentrations. Markers of inflammation, interleukins (IL-1b, IL-6, IL-8, and IL-10), C-reactive protein (CRP), serum amyloid A (SAA), and fibrinogen and markers of coagulation factor VIII, von Willebrand, plasminogen activator inhibitor, and D-dimer were measured in plasma or serum. Sampling was performed on the last day of the work free period of 5 days, before and after the shift the first day of work and after the shifts the second and third day. In a mixed model analysis, the relationship between particulate exposures and inflammatory markers was determined. Sex, age, smoking, and BMI were included as covariates. The average 8-h time-weighted average (TWA) air concentration levels of inhalable dust were 0.30 mg/m(3), range 0.005-3.3 mg/m(3). The proxies for average 8-h TWAs of respirable dust were 0.045 mg/m(3). Significant and consistent positive relations were found between several exposure metrics (PM 10, total and inhalable dust) and CRP, SAA and fibrinogen taken post-shift, suggesting a dose-effect relationship. This study supports a relationship between occupational particle exposure and established inflammatory markers, which may indicate an increased risk of cardiovascular disease.

  19. Estimating historical respirable crystalline silica exposures for Chinese pottery workers and iron/copper, tin, and tungsten miners.

    PubMed

    Zhuang, Z; Hearl, F J; Odencrantz, J; Chen, W; Chen, B T; Chen, J Q; McCawley, M A; Gao, P; Soderholm, S C

    2001-11-01

    Collaborative studies of Chinese workers, using over four decades of dust monitoring data, are being conducted by the National Institute for Occupational Safety and Health (NIOSH) and Tongji Medical University in China. The goal of these projects is to establish exposure-response relationships for the development of diseases such as silicosis or lung cancer in cohorts of pottery and mine workers. It is necessary to convert Chinese dust measurements to respirable silica measurements in order to make results from the Chinese data comparable to other results in the literature. This article describes the development of conversion factors and estimates of historical respirable crystalline silica exposure for Chinese workers. Ambient total dust concentrations (n>17000) and crystalline silica concentrations (n=347) in bulk dust were first gathered from historical industrial hygiene records. Analysis of the silica content in historical bulk samples revealed no trend from 1950 up to the present. During 1988-1989, side-by-side airborne dust samples (n=143 pairs) were collected using nylon cyclones and traditional Chinese samplers in 20 metal mines and nine pottery factories in China. These data were used to establish conversion factors between respirable crystalline silica concentrations and Chinese total dust concentrations. Based on the analysis of the available evidence, conversion factors derived from the 1988-1989 sampling campaign are assumed to apply to other time periods in this paper. The conversion factors were estimated to be 0.0143 for iron/copper, 0.0355 for pottery factories, 0.0429 for tin mines, and 0.0861 for tungsten mines. Conversion factors for individual facilities within each industry were also calculated. Analysis of variance revealed that mean conversion factors are significantly different among facilities within the iron/copper industry and within the pottery industry. The relative merits of using facility-specific conversion factors, industry-wide conversion factors, or a weighted average of the two are discussed. The exposure matrix of the historical Chinese total dust concentrations was multiplied by these conversion factors to obtain an exposure matrix of historical respirable crystalline silica concentrations.

  20. 30 CFR 70.300 - Respiratory equipment; respirable dust.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Respiratory equipment; respirable dust. 70.300... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.300 Respiratory equipment; respirable dust. Respiratory equipment approved by NIOSH under 42 CFR part 84 shall be...

  1. 30 CFR 70.300 - Respiratory equipment; respirable dust.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Respiratory equipment; respirable dust. 70.300... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.300 Respiratory equipment; respirable dust. Respiratory equipment approved by NIOSH under 42 CFR part 84 shall be...

  2. 30 CFR 70.300 - Respiratory equipment; respirable dust.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Respiratory equipment; respirable dust. 70.300... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.300 Respiratory equipment; respirable dust. Respiratory equipment approved by NIOSH under 42 CFR part 84 shall be...

  3. 30 CFR 70.300 - Respiratory equipment; respirable dust.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Respiratory equipment; respirable dust. 70.300... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.300 Respiratory equipment; respirable dust. Respiratory equipment approved by NIOSH under 42 CFR part 84 shall be...

  4. 30 CFR 70.300 - Respiratory equipment; respirable dust.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Respiratory equipment; respirable dust. 70.300... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Respiratory Equipment § 70.300 Respiratory equipment; respirable dust. Respiratory equipment approved by NIOSH under 42 CFR part 84 shall be...

  5. 30 CFR 72.700 - Respiratory equipment; respirable dust.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Respiratory equipment; respirable dust. 72.700... SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Miscellaneous § 72.700 Respiratory equipment; respirable dust. (a) Respiratory equipment approved by NIOSH under 42 CFR part 84 shall be made available to...

  6. Effect of the 2.0 mg/m3 coal mine dust standard on underground environmental dust levels.

    PubMed

    Parobeck

    1975-08-01

    The 1969 Federal Coal Mine Health and Safety Act established environmental dust standards for underground coal mines. The Act requires that the average concentration of respirable dust in the active workings of a mine be maintained at or below 3.0 mg/m3; and, that effective December 30, 1972, the 3.0 mg/m3 standard be reduced to 2.0 mg/m3. This paper discusses the current status of dust levels in our underground coal mines, the effect of the 2.0 mg/m3 standard on underground dust levels, and associates the current levels with specific operations and occupations. The comparison is made between current levels and those existing prior to December 30, 1972.

  7. Dust exposure during small-scale mining in Tanzania: a pilot study.

    PubMed

    Bratveit, Magne; Moen, Bente E; Mashalla, Yohana J S; Maalim, Hatua

    2003-04-01

    Small-scale mining in developing countries is generally labour-intensive and carried out with low levels of mechanization. In the Mererani area in the northern part of Tanzania, there are about 15000 underground miners who are constantly subjected to a poor working environment. Gemstones are found at depths down to 500 m. The objectives of this pilot study were to monitor the exposure to dust during work processes, which are typical of small-scale mining in developing countries, and to make a rough estimation of whether there is a risk of chronic pulmonary diseases for the workers. Personal sampling of respirable dust (n = 15) and 'total' dust (n = 5) was carried out during three consecutive days in one mine, which had a total of 50 workers in two shifts. Sampling started immediately before the miners entered the shaft, and lasted until they reappeared at the mine entrance after 5-8 h. The median crystalline silica content and the combustible content of the respirable dust samples were 14.2 and 5.5%, respectively. When drilling, blasting and shovelling were carried out, the exposure measurements showed high median levels of respirable dust (15.5 mg/m(3)), respirable crystalline silica (2.4 mg/m(3)), respirable combustible dust (1.5 mg/m(3)) and 'total' dust (28.4 mg/m(3)). When only shovelling and loading of sacks took place, the median exposures to respirable dust and respirable crystalline silica were 4.3 and 1.1 mg/m(3). This study shows that the exposure to respirable crystalline silica was high during underground small-scale mining. In the absence of personal protective equipment, the miners in the Mererani area are presumably at a high risk of developing chronic silicosis.

  8. Influence of continuous mining arrangements on respirable dust exposures

    PubMed Central

    Beck, T. W.; Organiscak, J. A.; Pollock, D. E.; Potts, J. D.; Reed, W. R.

    2017-01-01

    In underground continuous mining operations, ventilation, water sprays and machine-mounted flooded-bed scrubbers are the primary means of controlling respirable dust exposures at the working face. Changes in mining arrangements — such as face ventilation configuration, orientation of crosscuts mined in relation to the section ventilation and equipment operator positioning — can have impacts on the ability of dust controls to reduce occupational respirable dust exposures. This study reports and analyzes dust concentrations measured by the Pittsburgh Mining Research Division for remote-controlled continuous mining machine operators as well as haulage operators at 10 U.S. underground mines. The results of these respirable dust surveys show that continuous miner exposures varied little with depth of cut but are significantly higher with exhaust ventilation. Haulage operators experienced elevated concentrations with blowing face ventilation. Elevated dust concentrations were observed for both continuous miner operators and haulage operators when working in crosscuts driven into or counter to the section airflow. Individual cuts are highlighted to demonstrate instances of minimal and excessive dust exposures attributable to particular mining configurations. These findings form the basis for recommendations for lowering face worker respirable dust exposures. PMID:28529441

  9. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement

    PubMed Central

    Echt, Alan; Mead, Kenneth

    2016-01-01

    Purpose To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Approach Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. Results All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m−3. This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m−3 of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m−3. The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m3 s−1. Conclusions The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. PMID:26826033

  10. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement.

    PubMed

    Echt, Alan; Mead, Kenneth

    2016-05-01

    To assess the effectiveness of local exhaust ventilation to control respirable crystalline silica exposures to acceptable levels during concrete dowel drilling. Personal breathing zone samples for respirable dust and crystalline silica were collected while laborers drilled holes 3.5 cm diameter by 36 cm deep in a concrete slab using a single-drill slab-riding dowel drill equipped with local exhaust ventilation. Data were collected on air flow, weather, and productivity. All respirable dust samples were below the 90 µg detection limit which, when combined with the largest sample volume, resulted in a minimum detectable concentration of 0.31 mg m(-3). This occurred in a 32-min sample collected when 27 holes were drilled. Quartz was only detected in one air sample; 0.09 mg m(-3) of quartz was found on an 8-min sample collected during a drill maintenance task. The minimum detectable concentration for quartz in personal air samples collected while drilling was performed was 0.02 mg m(-3). The average number of holes drilled during each drilling sample was 23. Over the course of the 2-day study, air flow measured at the dust collector decreased from 2.2 to 1.7 m(3) s(-1). The dust control performed well under the conditions of this test. The initial duct velocity with a clean filter was sufficient to prevent settling, but gradually fell below the recommended value to prevent dust from settling in the duct. The practice of raising the drill between each hole may have prevented the dust from settling in the duct. A slightly higher flow rate and an improved duct design would prevent settling without regard to the position of the drill. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.

  11. 30 CFR 71.301 - Respirable dust control plan; approval by District Manager and posting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... District Manager and posting. 71.301 Section 71.301 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... plan; approval by District Manager and posting. (a) The District Manager will approve respirable dust control plans on a mine-by-mine basis. When approving respirable dust control plans, the District Manager...

  12. Respirable concrete dust--silicosis hazard in the construction industry.

    PubMed

    Linch, Kenneth D

    2002-03-01

    Concrete is an extremely important part of the infrastructure of modern life and must be replaced as it ages. Many of the methods of removing, repairing, or altering existing concrete structures have the potential for producing vast quantities of respirable dust. Since crystalline silica in the form of quartz is a major component of concrete, airborne respirable quartz dust may be produced during construction work involving the disturbance of concrete, thereby producing a silicosis hazard for exposed workers. Silicosis is a debilitating and sometimes fatal lung disease resulting from breathing microscopic particles of crystalline silica. Between 1992 and 1998, the National Institute for Occupational Safety and Health (NIOSH) made visits to construction projects where concrete was being mechanically disturbed in order to obtain data concerning respirable crystalline silica dust exposures. The construction activities studied included: abrasive blasting, concrete pavement sawing and drilling, and asphalt/concrete milling. Air samples of respirable dust were obtained using 10-mm nylon cyclone pre-separators, 37-mm polyvinyl chloride (PVC) filters, and constant-flow pumps calibrated at 1.7 L/min. In addition, high-volume respirable dust samples were obtained on 37-mm PVC filters using 1/2" metal cyclones (Sensidyne model 18) and constant-flow pumps calibrated at 9.0 L/min. Air sample analysis included total weight gain by gravimetric analysis according to NIOSH Analytical Method 600 and respirable crystalline silica (quartz and cristobalite) using x-ray diffraction, as per NIOSH Analytical Method 7500. For abrasive blasting of concrete structures, the respirable crystalline silica (quartz) concentration ranged up to 14.0 mg/m3 for a 96-minute sample resulting in an eight-hour time-weighted average (TWA) of 2.8 mg/m3. For drilling concrete highway pavement the respirable quartz concentrations ranged up to 4.4 mg/m3 for a 358-minute sample, resulting in an eight-hour TWA of 3.3 mg/m3. For concrete wall grinding during new building construction the respirable quartz measurements ranged up to 0.66 mg/m3 for a 191-minute sample, resulting in an eight-hour TWA of 0.26 mg/m3. The air sampling results for concrete sawing ranged up to 14.0 mg/m3 for a 350-minute sample resulting in an eight-hour TWA of 10.0 mg/m3. During the milling of asphalt from concrete highway pavement, the sampling indicated a respirable quartz concentration ranging up to 0.34 mg/m3 for a 504-minute sample, resulting in an eight-hour TWA of 0.36 mg/m3. The results of this work indicate the potential for respirable quartz concentrations involving disturbance of concrete to range up to 280 times the NIOSH Recommended Exposure Limit (REL) of 0.05 mg/m3 assuming exposure for an eight- to ten-hour workday. Considering the aging of the concrete infrastructure in the United States, these results pose a challenge to all who have an interest in preventing silica exposures and the associated disease silicosis.

  13. Air cleaning performance of a new environmentally controlled primary crusher operator booth.

    PubMed

    Organiscak, J A; Cecala, A B; Zimmer, J A; Holen, B; Baregi, J R

    2016-02-01

    The National Institute for Occupational Safety and Health (NIOSH) cooperated with 3M Company in the design and testing of a new environmentally controlled primary crusher operator booth at the company's Wausau granite quarry near Wausau, WI. This quarry had an older crusher booth without a central heating, ventilation and air conditioning (HVAC) system, and without an air filtration and pressurization system. A new replacement operator booth was designed and installed by 3M based on design considerations from past NIOSH research on enclosed cab filtration systems. NIOSH conducted pre-testing of the old booth and post-testing of the new booth to assess the new filtration and pressurization system's effectiveness in controlling airborne dusts and particulates. The booth's dust and particulate control effectiveness is described by its protection factor, expressed as a ratio of the outside to inside concentrations measured during testing. Results indicate that the old booth provided negligible airborne respirable dust protection and low particulate protection from the outside environment. The newly installed booth provided average respirable dust protection factors from 2 to 25 over five shifts of dust sampling with occasional worker ingress and egress from the booth, allowing some unfiltered contaminants to enter the enclosure. Shorter-term particle count testing outside and inside the booth under near-steady-state conditions, with no workers entering or exiting the booth, resulted in protection factors from 35 to 127 on 0.3- to 1.0-μm respirable size particulates under various HVAC airflow operating conditions.

  14. Radiographic abnormalities among construction workers exposed to quartz containing dust

    PubMed Central

    Tjoe, N; Burdorf, A; Parker, J; Attfield, M; van Duivenbooden, C; Heederik, D

    2003-01-01

    Background: Construction workers are exposed to quartz containing respirable dust, at levels that may cause fibrosis in the lungs. Studies so far have not established a dose-response relation for radiographic abnormalities for this occupational group. Aims: To measure the extent of radiographic abnormalities among construction workers primarily exposed to quartz containing respirable dust. Methods: A cross sectional study on radiographic abnormalities indicative of pneumoconiosis was conducted among 1339 construction workers mainly involved in grinding, (jack)-hammering, drilling, cutting, sawing, and polishing. Radiological abnormalities were determined by median results of the 1980 International Labour Organisation system of three certified "B" readers. Questionnaires were used for assessment of occupational history, presence of respiratory diseases, and symptoms and smoking habits. Results: An abnormality of ILO profusion category 1/0 and greater was observed on 10.2% of the chest radiographs, and profusion category of 1/1 or greater on 2.9% of the radiographs. The average duration of exposure of this group was 19 years and the average age was 42. The predominant type of small opacities (irregularly shaped) is presumably indicative of mixed dust pneumoconiosis. The prevalence of early signs of nodular silicosis (small rounded opacities of category 1/0 or greater) was low (0.8%). Conclusions: The study suggests an elevated risk of radiographic abnormalities among these workers with expected high exposure. An association between radiographic abnormalities and cumulative exposure to quartz containing dust from construction sites was observed, after correction for potentially confounding variables. PMID:12771392

  15. An evaluation of on-tool shrouds for controlling respirable crystalline silica in restoration stone work.

    PubMed

    Healy, Catherine B; Coggins, Marie A; Van Tongeren, Martie; MacCalman, Laura; McGowan, Padraic

    2014-11-01

    The task of grinding sandstone with a 5-inch angle grinder is a major source of exposure to respirable crystalline silica (RCS), known to cause diseases such as silicosis and lung cancer among workers who work with these materials. A shroud may be a suitable engineering control for this task. The objectives of this study were to evaluate the effectiveness of four commercially available shrouds at reducing respirable dust and RCS levels during the task of grinding sandstone using tools and accessories typical of restoration stone work. The task of grinding sandstone with a 5-inch angle grinder, equipped with different grinding wheels, was carried out over three trials at a restoration stone masonry site. Photometric and RCS data were collected when a 5-inch grinder, equipped with different grinding wheels, was used to grind sandstone with and without a shroud. A total of 24 short duration samples were collected for each no shroud and with shroud combination. Worker feedback on the practicalities of each shroud evaluated was also collected. Respirable dust concentrations and RCS were both significantly lower (P < 0.001) when the grinders were equipped with a shroud compared with grinders without a shroud. Total geometric mean (GM) photometric respirable dust levels measured when grinding with a shroud were 0.5 mg m(-3), a reduction of 92% compared to grinding without a shroud (7.1 mg m(-3)). The overall GM RCS concentrations were reduced by the use of a shroud by 99%. GM photometric exposure levels were highest when using the Hilti 5-inch diamond grinding cup and Diamond turbo cup and lowest when using the Corundum grinding point. Concentrations of respirable dust and RCS can be significantly reduced by using commercially available shrouds while grinding sandstone with a 5-inch angle grinder in restoration stonework. The short-term photometric respirable dust and RCS measurements collected with and without a shroud indicate that dust and RCS concentrations are reduced by between 90 and 99%. Supplemental exposure controls such as respiratory protective equipment would be required to reduce worker 8-h time-weighted average RCS exposure to below the Scientific Committee on Occupational Exposure Limits recommended occupational exposure limit value of 0.05 mg m(-3) and the American Conference of Governmental Industrial Hygienists threshold limit value of 0.025 mg m(-3). © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  16. Factors influencing dust exposure: finishing activities in drywall construction.

    PubMed

    Simmons, Catherine E; Jones, Rachael M; Boelter, Fred W

    2011-05-01

    Sanding drywall joint compound is a dusty construction activity. We studied potential factors influencing exposure to respirable and total dust for sanders and bystanders in the area of drywall joint compound finishing in 17 test events within a room-scale isolation chamber. We found the air change rate to be negatively correlated with dust C(twa) both in the sander's personal breathing zone and surrounding area. We could not conclude that sanding tool type systematically influences dust C(twa), but the use of 80-grit abrasive was associated with the highest dust C(twa). We found respirable dusts were uniformly dispersed 1-8.2 m from sanding activities at a fixed location. As anticipated, both respirable and total dust C(twa) in the sander's personal breathing zone are higher than in the surrounding area. The respirable fraction of the total dust mass C(twa) was greater in the surrounding area than in the sander's personal breathing zone. Respirable dust concentrations measured in real time increased over the duration of sanding, exhibiting a temporal trend that is similar to that predicted by the well-mixed box model with contaminant removal by mechanical ventilation only, and continuous emission. Dust concentrations returned to pre-activity (background) levels 2-4 hr after cessation of the sanding activity.

  17. Contributions of dust exposure and cigarette smoking to emphysema severity in coal miners in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuempel, E.D.; Wheeler, M.W.; Smith, R.J.

    Previous studies have shown associations between dust exposure or lung burden and emphysema in coal miners, although the separate contributions of various predictors have not been clearly demonstrated. The objective was to quantitatively evaluate the relationship between cumulative exposure to respirable coal mine dust, cigarette smoking, and other factors on emphysema severity. The study group included 722 autopsied coal miners and nonminers in the United States. Data on work history, smoking, race, and age at death were obtained from medical records and questionnaire completed by next-of-kin. Emphysema was classified and graded using a standardized schema. Job-specific mean concentrations of respirablemore » coal mine dust were matched with work histories to estimate cumulative exposure. Relationships between various metrics of dust exposure (including cumulative exposure and lung dust burden) and emphysema severity were investigated in weighted least squares regression models. Emphysema severity was significantly elevated in coal miners compared with nonminers among ever- and never-smokers (P < 0.0001). Cumulative exposure to respirable coal mine dust or coal dust retained in the lungs were significant predictors of emphysema severity (P < 0.0001) after accounting for cigarette smoking, age at death, and race. The contributions of coal mine dust exposure and cigarette smoking were similar in predicting emphysema severity averaged over this cohort. Coal dust exposure, cigarette smoking, age, and race are significant and additive predictors of emphysema severity in this study.« less

  18. 30 CFR 70.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... operator shall not open or tamper with the seal of any filter cassette or alter the weight of any filter... accordance with § 70.202 (Certified person; sampling) shall properly complete the dust data card that is.... Respirable dust samples with data cards not properly completed will be voided by MSHA. (d) All respirable...

  19. 30 CFR 70.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... operator shall not open or tamper with the seal of any filter cassette or alter the weight of any filter... accordance with § 70.202 (Certified person; sampling) shall properly complete the dust data card that is.... Respirable dust samples with data cards not properly completed will be voided by MSHA. (d) All respirable...

  20. The Generation Rate of Respirable Dust from Cutting Fiber Cement Siding Using Different Tools

    PubMed Central

    Qi, Chaolong; Echt, Alan; Gressel, Michael G

    2017-01-01

    This article describes the evaluation of the generation rate of respirable dust (GAPS, defined as the mass of respirable dust generated per unit linear length cut) from cutting fiber cement siding using different tools in a laboratory testing system. We used an aerodynamic particle sizer spectrometer (APS) to continuously monitor the real-time size distributions of the dust throughout cutting tests when using a variety of tools, and calculated the generation rate of respirable dust for each testing condition using the size distribution data. The test result verifies that power shears provided an almost dust-free operation with a GAPS of 0.006 gram meter−1 (g m−1) at the testing condition. For the same power saws, the cuts using saw blades with more teeth generated more respirable dusts. Using the same blade for all four miter saws tested in this study, a positive linear correlation was found between the saws’ blade rotating speed and its dust generation rate. In addition, a circular saw running at the highest blade rotating speed of 9068 RPM generated the greatest amount of dust. All the miter saws generated less dust in the ‘chopping mode’ than in the ‘chopping and sliding’ mode. For the tested saws, GAPS consistently decreased with the increases of the saw cutting feed rate and the number of board in the stack. All the test results point out that fewer cutting interactions between the saw blade’s teeth and the siding board for a unit linear length of cut tend to result in a lower generation rate of respirable dust. These results may help guide optimal operation in practice and future tool development aimed at minimizing dust generation while producing a satisfactory cut. PMID:28395343

  1. The Generation Rate of Respirable Dust from Cutting Fiber Cement Siding Using Different Tools.

    PubMed

    Qi, Chaolong; Echt, Alan; Gressel, Michael G

    2017-03-01

    This article describes the evaluation of the generation rate of respirable dust (GAPS, defined as the mass of respirable dust generated per unit linear length cut) from cutting fiber cement siding using different tools in a laboratory testing system. We used an aerodynamic particle sizer spectrometer (APS) to continuously monitor the real-time size distributions of the dust throughout cutting tests when using a variety of tools, and calculated the generation rate of respirable dust for each testing condition using the size distribution data. The test result verifies that power shears provided an almost dust-free operation with a GAPS of 0.006 g m-1 at the testing condition. For the same power saws, the cuts using saw blades with more teeth generated more respirable dusts. Using the same blade for all four miter saws tested in this study, a positive linear correlation was found between the saws' blade rotating speed and its dust generation rate. In addition, a circular saw running at the highest blade rotating speed of 9068 rpm generated the greatest amount of dust. All the miter saws generated less dust in the 'chopping mode' than in the 'chopping and sliding' mode. For the tested saws, GAPS consistently decreased with the increases of the saw cutting feed rate and the number of board in the stack. All the test results point out that fewer cutting interactions between the saw blade's teeth and the siding board for a unit linear length of cut tend to result in a lower generation rate of respirable dust. These results may help guide optimal operation in practice and future tool development aimed at minimizing dust generation while producing a satisfactory cut. Published by Oxford University Press on behalf of The British Occupational Hygiene Society 2017.

  2. [Comparative studies of personal and steady-state sampling for determining dust exposure in different job groups].

    PubMed

    Cherneva, P; Lukanova, R

    1994-01-01

    The variability of the dust concentration in time and space, as well as the change of worker's place during the working process, define the necessity of introducing personal sampling in the hygiene control practice. However, the laboratory equipment with personal devices is still not sufficient. The aim of this work is to assess the dust exposure of the basic professional groups from the ore- and coal production in Bulgaria by personal sampling in comparative studies of the static ambient sampling used up to now. 63 full-shift investigations of the dust factor were performed on professional groups of miners of the polymetal and coal pits by static ambient devices-[Hygitest production] and personal [from firms "Casella", "Strolein" and "Gilian"] devices, after standardized methods. The results are data processed-by means of logarithmic normal distribution of the relation of the respirable dust concentrations, determined personally and by static ambient sampling. The limits of variation of this correlation are from 0.5 to 4.1 at average geometric value -0.95 and standard geometric deviation-1.8 i.e. both types of sampling are intersubstitutional for the examined groups and sites, as in the underground ores the professional risk of respirable dust is underestimated up to 4 times at static ambient sampling.

  3. Dust control effectiveness of drywall sanding tools.

    PubMed

    Young-Corbett, Deborah E; Nussbaum, Maury A

    2009-07-01

    In this laboratory study, four drywall sanding tools were evaluated in terms of dust generation rates in the respirable and thoracic size classes. In a repeated measures study design, 16 participants performed simulated drywall finishing tasks with each of four tools: (1) ventilated sander, (2) pole sander, (3) block sander, and (4) wet sponge. Dependent variables of interest were thoracic and respirable breathing zone dust concentrations. Analysis by Friedman's Test revealed that the ventilated drywall sanding tool produced significantly less dust, of both size classes, than did the other three tools. The pole and wet sanders produced significantly less dust of both size classes than did the block sander. The block sander, the most commonly used tool in drywall finishing operations, produced significantly more dust of both size classes than did the other three tools. When compared with the block sander, the other tools offer substantial dust reduction. The ventilated tool reduced respirable concentrations by 88% and thoracic concentrations by 85%. The pole sander reduced respirable concentrations by 58% and thoracic by 50%. The wet sander produced reductions of 60% and 47% in the respirable and thoracic classes, respectively. Wet sponge sanders and pole sanders are effective at reducing breathing-zone dust concentrations; however, based on its superior dust control effectiveness, the ventilated sander is the recommended tool for drywall finishing operations.

  4. Exposures to thoracic particulate matter, endotoxin, and glucan during post-Hurricane Katrina restoration work, New Orleans 2005-2012.

    PubMed

    Rando, Roy J; Kwon, Cheol-Woong; Lefante, John J

    2014-01-01

    In the aftermath of Hurricane Katrina, which devastated the city of New Orleans in August 2005, restoration workers were at risk for respiratory illness from exposure to airborne particles and microbial agents. In support of an epidemiologic investigation of this risk, an exposure assessment for restoration work activities (demolition, trash & debris management, landscape restoration, sewer/waterline repair, and mold remediation) was performed from 2005 to 2012. For 2005 and 2006, Occupational Safety and Health Administration (OSHA) data (n = 730) for personal and area monitoring of total and respirable dust exposures of restoration workers were accessed and analyzed. The most significant exposures were for demolition work, with average respirable dust exposures in 2005 above the action level of 2.5 mg/m(3) and 17.6% of exposures exceeding the permissible exposure limit (PEL) (5 mg/m(3)). Additional personal and area monitoring for thoracic particulate matter was performed from 2007 to 2012 (n = 774) and samples were assayed for endotoxin and (1→3, 1→6)-β-D-glucan (n = 202). In order to integrate the OSHA data with the later monitoring data, three independent predictive models were developed to convert total and respirable dust measures into the equivalent thoracic dust. The three models were not statistically different and the modeling results were in good agreement with an overall coefficient of variation of 16% for the thoracic dust means across work activities estimated by each of the three models. Overall, thoracic dust exposure levels decreased by about an order of magnitude within the first year after Katrina and then more gradually declined and stabilized through 2012. Estimated average exposures to endotoxin and microbial glucan in 2005 were as high as 256 EU/m(3) and 118 μg/m(3), respectively, and likewise were seen to decrease dramatically and stabilize after 2005. The results of this exposure assessment support previously published reports of respiratory illness including sinusitis, toxic pneumonitis, and Katrina Cough among restoration workers in the years immediately after the hurricane.

  5. Use of Recirculating Ventilation with Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room

    PubMed Central

    Anthony, T. Renée; Altmaier, Ralph; Jones, Samuel; Gassman, Rich; Park, Jae Hong; Peters, Thomas M.

    2016-01-01

    The performance of a recirculating ventilation system with dust filtration was evaluated to determine its effectiveness to improve the air quality in a swine farrowing room of a concentrated animal feeding operation (CAFO). Air was exhausted from the room (0.47 m3sec−1; 1000 cfm), treated with a filtration unit (Shaker-Dust Collector), and returned to the farrowing room to reduce dust concentrations while retaining heat necessary for livestock health. The air quality in the room was assessed over a winter, during which time limited fresh air is traditionally brought into the building. Over the study period, dust concentrations ranged from 0.005 to 0.31 mg m−3 (respirable) and 0.17 to 2.09 mg m−3 (inhalable). In-room dust concentrations were reduced (41% for respirable and 33% for inhalable) with the system in operation, while gas concentrations (ammonia [NH3], hydrogen sulfide [H2S], carbon monoxide [CO], carbon dioxide [CO2]) were unchanged. The position of the exhaust and return air systems provided reasonably uniform contaminant distributions, although the respirable dust concentrations nearest one of the exhaust ducts was statistically higher than other locations in the room, with differences averaging only 0.05 mg m−3. Throughout the study, CO2 concentrations consistently exceeded 1540 ppm (industry recommendations) and on eight of the 18 study days it exceeded 2500 ppm (50% of the ACGIH TLV), with significantly higher concentrations near a door to a temperature-controlled hallway that was typically often left open. Alternative heaters are recommended to reduce CO2 concentrations in the room. Contaminant concentrations were modeled using production and environmental factors, with NH3 related to the number of sow in the room and outdoor temperatures and CO2 related to the number of piglets and outdoor temperatures. The recirculating ventilation system provided dust reduction without increasing concentrations of hazardous gases. PMID:25950713

  6. Air cleaning performance of a new environmentally controlled primary crusher operator booth

    PubMed Central

    Organiscak, J.A.; Cecala, A.B.; Zimmer, J.A.; Holen, B.; Baregi, J.R.

    2016-01-01

    The National Institute for Occupational Safety and Health (NIOSH) cooperated with 3M Company in the design and testing of a new environmentally controlled primary crusher operator booth at the company’s Wausau granite quarry near Wausau, WI. This quarry had an older crusher booth without a central heating, ventilation and air conditioning (HVAC) system, and without an air filtration and pressurization system. A new replacement operator booth was designed and installed by 3M based on design considerations from past NIOSH research on enclosed cab filtration systems. NIOSH conducted pre-testing of the old booth and post-testing of the new booth to assess the new filtration and pressurization system’s effectiveness in controlling airborne dusts and particulates. The booth’s dust and particulate control effectiveness is described by its protection factor, expressed as a ratio of the outside to inside concentrations measured during testing. Results indicate that the old booth provided negligible airborne respirable dust protection and low particulate protection from the outside environment. The newly installed booth provided average respirable dust protection factors from 2 to 25 over five shifts of dust sampling with occasional worker ingress and egress from the booth, allowing some unfiltered contaminants to enter the enclosure. Shorter-term particle count testing outside and inside the booth under near-steady-state conditions, with no workers entering or exiting the booth, resulted in protection factors from 35 to 127 on 0.3- to 1.0-μm respirable size particulates under various HVAC airflow operating conditions. PMID:26937052

  7. Silica dust exposure: Effect of filter size to compliance determination

    NASA Astrophysics Data System (ADS)

    Amran, Suhaily; Latif, Mohd Talib; Khan, Md Firoz; Leman, Abdul Mutalib; Goh, Eric; Jaafar, Shoffian Amin

    2016-11-01

    Monitoring of respirable dust was performed using a set of integrated sampling system consisting of sampling pump attached with filter media and separating device such as cyclone or special cassette. Based on selected method, filter sizes are either 25 mm or 37 mm poly vinyl chloride (PVC) filter. The aim of this study was to compare performance of two types of filter during personal respirable dust sampling for silica dust under field condition. The comparison strategy focused on the final compliance judgment based on both dataset. Eight hour parallel sampling of personal respirable dust exposure was performed among 30 crusher operators at six quarries. Each crusher operator was attached with parallel set of integrated sampling train containing either 25 mm or 37 mm PVC filter. Each set consisted of standard flow SKC sampler, attached with SKC GS3 cyclone and 2 pieces cassette loaded with 5.0 µm of PVC filter. Samples were analyzed by gravimetric technique. Personal respirable dust exposure between the two types of filters indicated significant positive correlation (p < 0.05) with moderate relationship (r2 = 0.6431). Personal exposure based on 25 mm PVC filter indicated 0.1% non-compliance to overall data while 37 mm PVC filter indicated similar findings at 0.4 %. Both data showed similar arithmetic mean(AM) and geometric mean(GM). In overall we concluded that personal respirable dust exposure either based on 25mm or 37mm PVC filter will give similar compliance determination. Both filters are reliable to be used in respirable dust monitoring for silica dust related exposure.

  8. 42 CFR 84.1145 - Silica dust test; non-powered single-use dust respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Silica dust test; non-powered single-use dust respirators; minimum requirements. 84.1145 Section 84.1145 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  9. 42 CFR 84.1145 - Silica dust test; non-powered single-use dust respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Silica dust test; non-powered single-use dust respirators; minimum requirements. 84.1145 Section 84.1145 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  10. 42 CFR 84.1145 - Silica dust test; non-powered single-use dust respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Silica dust test; non-powered single-use dust respirators; minimum requirements. 84.1145 Section 84.1145 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  11. 42 CFR 84.1145 - Silica dust test; non-powered single-use dust respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Silica dust test; non-powered single-use dust respirators; minimum requirements. 84.1145 Section 84.1145 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  12. 42 CFR 84.1145 - Silica dust test; non-powered single-use dust respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Silica dust test; non-powered single-use dust respirators; minimum requirements. 84.1145 Section 84.1145 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  13. Treated and untreated rock dust: Quartz content and physical characterization.

    PubMed

    Soo, Jhy-Charm; Lee, Taekhee; Chisholm, William P; Farcas, Daniel; Schwegler-Berry, Diane; Harper, Martin

    2016-11-01

    Rock dusting is used to prevent secondary explosions in coal mines, but inhalation of rock dusts can be hazardous if the crystalline silica (e.g., quartz) content in the respirable fraction is high. The objective of this study is to assess the quartz content and physical characteristics of four selected rock dusts, consisting of limestone or marble in both treated (such as treatment with stearic acid or stearates) and untreated forms. Four selected rock dusts (an untreated and treated limestone and an untreated and treated marble) were aerosolized in an aerosol chamber. Respirable size-selective sampling was conducted along with particle size-segregated sampling using a Micro-Orifice Uniform Deposit Impactor. Fourier Transform Infrared spectroscopy and scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) analyses were used to determine quartz mass and particle morphology, respectively. Quartz percentage in the respirable dust fraction of untreated and treated forms of the limestone dust was significantly higher than in bulk samples, but since the bulk percentage was low the enrichment factor would not have resulted in any major change to conclusions regarding the contribution of respirable rock dust to the overall airborne quartz concentration. The quartz percentage in the marble dust (untreated and treated) was very low and the respirable fractions showed no enrichment. The spectra from SEM-EDX analysis for all materials were predominantly from calcium carbonate, clay, and gypsum particles. No free quartz particles were observed. The four rock dusts used in this study are representative of those presented for use in rock dusting, but the conclusions may not be applicable to all available materials.

  14. Cumulative exposure to dust causes accelerated decline in lung function in tunnel workers

    PubMed Central

    Ulvestad, B; Bakke, B; Eduard, W; Kongerud, J; Lund, M

    2001-01-01

    OBJECTIVES—To examine whether underground construction workers exposed to tunnelling pollutants over a follow up period of 8 years have an increased risk of decline in lung function and respiratory symptoms compared with reference subjects working outside the tunnel atmosphere, and relate the findings to job groups and cumulative exposure to dust and gases.
METHODS—96 Tunnel workers and a reference group of 249 other heavy construction workers were examined in 1991 and re-examined in 1999. Exposure measurements were carried out to estimate personal cumulative exposure to total dust, respirable dust, α-quartz, oil mist, and nitrogen dioxide. The subjects answered a questionnaire on respiratory symptoms and smoking habits, performed spirometry, and had chest radiographs taken. Radiological signs of silicosis were evaluated (International Labour Organisation (ILO) classification). Atopy was determined by a multiple radioallergosorbent test (RAST).
RESULTS—The mean exposure to respirable dust and α-quartz in tunnel workers varied from 1.2-3.6 mg/m3 (respirable dust) and 0.019-0.044 mg/m3 (α-quartz) depending on job task performed. Decrease in forced expiratory volume in 1 second (FEV1) was associated with cumulative exposure to respirable dust (p<0.001) and α-quartz (p=0.02). The multiple regression model predicted that in a worker 40 years of age, the annual decrease in FEV1 would be 25 ml in a non-exposed non-smoker, 35 ml in a non-exposed smoker, and 50-63 ml in a non-smoking tunnel worker (depending on job). Compared with the reference group the odds ratio for the occurrence of new respiratory symptoms during the follow up period was increased in the tunnel workers and associated with cumulative exposure to respirable dust.
CONCLUSIONS—Cumulative exposures to respirable dust and α-quartz are the most important risk factors for airflow limitation in underground heavy construction workers, and cumulative exposure to respirable dust is the most important risk factor for respiratory symptoms. The finding of accelerated decline in lung function in tunnel workers suggests that better control of exposures is needed.


Keywords: heavy construction; respirable dust; lung function PMID:11555688

  15. Respirable dust and quartz exposure from three South African farms with sandy, sandy loam, and clay soils.

    PubMed

    Swanepoel, Andrew J; Kromhout, Hans; Jinnah, Zubair A; Portengen, Lützen; Renton, Kevin; Gardiner, Kerry; Rees, David

    2011-07-01

    To quantify personal time-weighted average respirable dust and quartz exposure on a sandy, a sandy loam, and a clay soil farm in the Free State and North West provinces of South Africa and to ascertain whether soil type is a determinant of exposure to respirable quartz. Three farms, located in the Free State and North West provinces of South Africa, had their soil type confirmed as sandy, sandy loam, and clay; and, from these, a total of 298 respirable dust and respirable quartz measurements were collected between July 2006-November 2009 during periods of major farming operations. Values below the limit of detection (LOD) (22 μg · m(-3)) were estimated using multiple 'imputation'. Non-parametric tests were used to compare quartz exposure from the three different soil types. Exposure to respirable quartz occurred on all three farms with the highest individual concentration measured on the sandy soil farm (626 μg · m(-3)). Fifty-seven, 59, and 81% of the measurements on the sandy soil, sandy loam soil, and clay soil farm, respectively, exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) of 25 μg · m(-3). Twelve and 13% of respirable quartz concentrations exceeded 100 μg · m(-3) on the sandy soil and sandy loam soil farms, respectively, but none exceeded this level on the clay soil farm. The proportions of measurements >100 μg · m(-3) were not significantly different between the sandy and sandy loam soil farms ('prop.test'; P = 0.65), but both were significantly larger than for the clay soil farm ('prop.test'; P = 0.0001). The percentage of quartz in respirable dust was determined for all three farms using measurements > the limit of detection. Percentages ranged from 0.5 to 94.4% with no significant difference in the median quartz percentages across the three farms (Kruskal-Wallis test; P = 0.91). This study demonstrates that there is significant potential for over-exposure to respirable quartz in farming and even clay soil farming may pose a risk. Soil type may determine whether exposure is >100 μg · m(3), but the job type and the manner in which the task is performed (e.g. mechanical or manual) may be important determinants of exposure. Identifying quartz exposure determinants (e.g. type of job) and modifiers will be of value to focus implementation of controls of particular importance in developing countries.

  16. 42 CFR 84.1144 - Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum requirements. 84.1144 Section 84.1144 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH...

  17. 42 CFR 84.1144 - Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum requirements. 84.1144 Section 84.1144 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH...

  18. 42 CFR 84.1144 - Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum requirements. 84.1144 Section 84.1144 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH...

  19. 42 CFR 84.1144 - Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum requirements. 84.1144 Section 84.1144 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH...

  20. 42 CFR 84.1144 - Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Silica dust test for dust, fume, and mist respirators; single-use or reusable filters; minimum requirements. 84.1144 Section 84.1144 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH...

  1. 75 FR 64411 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-19

    ...The Mine Safety and Health Administration (MSHA) proposes to lower miners' exposure to respirable coal mine dust by revising the Agency's existing standards on miners' occupational exposure to respirable coal mine dust. The major provisions of the proposal would lower the existing exposure limit; provide for full-shift sampling; redefine the term ``normal production shift; '' and add reexamination and decertification requirements for persons certified to sample, and maintain and calibrate sampling devices. In addition, the proposed rule would provide for single shift compliance sampling under the mine operator and MSHA's inspector sampling programs, and would establish sampling requirements for use of the Continuous Personal Dust Monitor (CPDM) and expanded requirements for medical surveillance. The proposed rule would significantly improve health protections for this Nation's coal miners by reducing their occupational exposure to respirable coal mine dust and lowering the risk that they will suffer material impairment of health or functional capacity over their working lives.

  2. Silica exposure assessment in a mortality study of Vermont granite workers.

    PubMed

    Verma, Dave K; Vacek, Pamela M; des Tombe, Karen; Finkelstein, Murray; Branch, Barbara; Gibbs, Graham W; Graham, William G

    2011-02-01

    A study of past silica and respirable dust exposures in the Vermont granite industry was conducted to develop a job exposure matrix (JEM) that used 5204 industrial hygiene measurements made from 1924-2004. The construction of the JEM involved data entry from several original sources into an Excel database that was reviewed later to ensure accuracy. Exposure measurements by job or location were grouped in two broad categories of quarry or shed and then into 22 job classes. Missing exposure data by time period were computed, taking into account improvements in dust control and periods of significant reduction in dustiness. Percent free silica (α-quartz) in respirable dust was estimated to be 11.0% based on previous published studies in Vermont and on data in the current database. About 60% of all measurement data (primarily from years prior to 1972) were obtained using the impinger and expressed in millions of particles per cubic foot (mppcf), which were converted to equivalent respirable free silica concentrations using the conversion of 10 mppcf = 0.1 mg/m(3) of respirable silica. For impinger data, respirable dust was calculated by multiplying respirable silica by a factor of 9.091 to reflect that the respirable silica was 11.0% respirable dust. This JEM has been used in a recent epidemiologic study to assess mortality in Vermont granite workers and to examine the relationships among mortality from silicosis, lung cancer, and other nonmalignant respiratory diseases.

  3. Characterization of airborne float coal dust emitted during continuous mining, longwall mining and belt transport.

    PubMed

    Shahan, M R; Seaman, C E; Beck, T W; Colinet, J F; Mischler, S E

    2017-09-01

    Float coal dust is produced by various mining methods, carried by ventilating air and deposited on the floor, roof and ribs of mine airways. If deposited, float dust is re-entrained during a methane explosion. Without sufficient inert rock dust quantities, this float coal dust can propagate an explosion throughout mining entries. Consequently, controlling float coal dust is of critical interest to mining operations. Rock dusting, which is the adding of inert material to airway surfaces, is the main control technique currently used by the coal mining industry to reduce the float coal dust explosion hazard. To assist the industry in reducing this hazard, the Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health initiated a project to investigate methods and technologies to reduce float coal dust in underground coal mines through prevention, capture and suppression prior to deposition. Field characterization studies were performed to determine quantitatively the sources, types and amounts of dust produced during various coal mining processes. The operations chosen for study were a continuous miner section, a longwall section and a coal-handling facility. For each of these operations, the primary dust sources were confirmed to be the continuous mining machine, longwall shearer and conveyor belt transfer points, respectively. Respirable and total airborne float dust samples were collected and analyzed for each operation, and the ratio of total airborne float coal dust to respirable dust was calculated. During the continuous mining process, the ratio of total airborne float coal dust to respirable dust ranged from 10.3 to 13.8. The ratios measured on the longwall face were between 18.5 and 21.5. The total airborne float coal dust to respirable dust ratio observed during belt transport ranged between 7.5 and 21.8.

  4. 30 CFR 90.100 - Respirable dust standard.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Dust Standards, Rights of Part 90 Miners § 90.100 Respirable dust standard. After the twentieth calendar day following receipt of notification from MSHA that a Part 90 miner is employed at the mine, the operator shall...

  5. Laboratory evaluation to reduce respirable crystalline silica dust when cutting concrete roofing tiles using a masonry saw.

    PubMed

    Carlo, Rebecca V; Sheehy, John; Feng, H Amy; Sieber, William K

    2010-04-01

    Respirable crystalline silica dust exposure in residential roofers is a recognized hazard resulting from cutting concrete roofing tiles. Roofers cutting tiles using masonry saws can be exposed to high concentrations of respirable dust. Silica exposures remain a serious threat for nearly two million U.S. construction workers. Although it is well established that respiratory diseases associated with exposure to silica dust are preventable, they continue to occur and cause disability or death. The effectiveness of both a commercially available local exhaust ventilation (LEV) system and a water suppression system in reducing silica dust was evaluated separately. The LEV system exhausted 0.24, 0.13, or 0.12 m(3)/sec of dust laden air, while the water suppression system supplied 0.13, 0.06, 0.03, or 0.02 L/sec of water to the saw blade. Using a randomized block design, implemented under laboratory conditions, the aforementioned conditions were evaluated independently on two types of concrete roofing tiles (s-shape and flat) using the same saw and blade. Each engineering control (LEV or water suppression) was replicated eight times, or four times for each type of tile. Analysis of variance was performed by comparing the mean airborne respirable dust concentrations generated during each run and engineering control treatment. The use of water controls and ventilation controls compared with the "no control" treatment resulted in a statistically significant (p < 0.05) reduction of mean respirable dust concentrations generated per tile cut. The percent reduction for respirable dust concentrations was 99% for the water control and 91% for the LEV. Results suggest that water is an effective method for reducing crystalline silica exposures. However, water damage potential, surface discolorations, cleanup, slip hazards, and other requirements may make the use of water problematic in many situations. Concerns with implementing an LEV system to control silica dust exposures include sufficient capture velocity, additional weight of the saw with the LEV system, electricity connections, and cost of air handling unit.

  6. Occupational Exposure to Respirable Dust, Respirable Crystalline Silica and Diesel Engine Exhaust Emissions in the London Tunnelling Environment.

    PubMed

    Galea, Karen S; Mair, Craig; Alexander, Carla; de Vocht, Frank; van Tongeren, Martie

    2016-03-01

    Personal 8-h shift exposure to respirable dust, diesel engine exhaust emissions (DEEE) (as respirable elemental carbon), and respirable crystalline silica of workers involved in constructing an underground metro railway tunnel was assessed. Black carbon (BC) concentrations were also assessed using a MicroAeth AE51. During sprayed concrete lining (SCL) activities in the tunnel, the geometric mean (GM) respirable dust exposure level was 0.91mg m(-3), with the highest exposure measured on a back-up sprayer (3.20mg m(-3)). The GM respirable crystalline silica concentration for SCL workers was 0.03mg m(-3), with the highest measurement also for the back-up sprayer (0.24mg m(-3)). During tunnel boring machine (TBM) activities, the GM respirable dust concentration was 0.54mg m(-3). The GM respirable elemental carbon concentration for all the TBM operators was 18 µg m(-3); with the highest concentration measured on a segment lifter. The BC concentrations were higher in the SCL environment in comparison to the TBM environment (daily GM 18-54 µg m(-3) versus 3-6 µg m(-3)). This small-scale monitoring campaign provides additional personal data on exposures experienced by underground tunnel construction workers. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  7. Work related decrement in pulmonary function in silicon carbide production workers.

    PubMed Central

    Osterman, J W; Greaves, I A; Smith, T J; Hammond, S K; Robins, J M; Thériault, G

    1989-01-01

    The relation between pulmonary function, cigarette smoking, and exposure to mixed respirable dust containing silicon carbide (SiC), hydrocarbons, and small quantities of quartz, cristobalite, and graphite was evaluated in 156SiC production workers using linear regression models on the difference between measured and predicted FEV1 and FVC. Workers had an average of 16 (range 2-41) years of employment and 9.5 (range 0.6-39.7) mg-year/m3 cumulative respirable dust exposure; average dust exposure while employed was 0.63 (range 0.18-1.42) mg/m3. Occasional, low level (less than or equal to 1.5 ppm) sulphur dioxide (SO2) exposure also occurred. Significant decrements in FEV1 (8.2 ml; p less than 0.03) and FVC (9.4 ml; p less than 0.01) were related to each year of employment for the entire group. Never smokers lost 17.8 ml (p less than 0.02) of FEV1 and 17.0 (p less than 0.05) of FVC a year, whereas corresponding decrements of 9.1 ml (p = 0.12) in FEV1 and 14.4 ml (p less than 0.02) in FVC were found in current smokers. Similar losses in FEV1 and FVC were related to each mg-year/m3 of cumulative dust exposure for 138 workers with complete exposure information; these findings, however, were generally not significant owing to the smaller cohort and greater variability in this exposure measure. Never smokers had large decrements in FEV1 (40.7 ml; p less than 0.02) and FVC (32.9 ml; p = 0.08) per mg-year/m3 of cumulative dust exposure and non-significant decrements were found in current smokers (FEV1: -7.1 ml; FVC: -11.7 ml). A non-significant decrement in lung function was also related to average dust exposure while employed. No changes were associated with SO(2) exposure or and SO(2) dust interaction. These findings suggest that employment in SiC production is associated with an excessive decrement in pulmonary function and that current permissible exposure limits for dusts occurring in this industry may not adequately protect workers from developing chronic pulmonary disease. PMID:2818959

  8. 30 CFR 72.800 - Single, full-shift measurement of respirable coal mine dust.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... coal mine dust. 72.800 Section 72.800 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Miscellaneous § 72.800 Single, full-shift measurement of respirable coal mine dust. The Secretary will use a single, full-shift...

  9. 30 CFR 90.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...

  10. 30 CFR 90.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...

  11. 30 CFR 71.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...

  12. 30 CFR 71.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... designated by the District Manager. (b) The operator shall not open or tamper with the seal of any filter... properly complete the dust data card that is provided by the manufacturer for each filter cassette. The... include that person's certification number. Respirable dust samples with data cards not properly completed...

  13. 42 CFR 84.1152 - Silica dust loading test; respirators designed as protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cubic meter and against radionuclides; minimum requirements. 84.1152 Section 84.1152 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH... 42 Public Health 1 2013-10-01 2013-10-01 false Silica dust loading test; respirators designed as...

  14. 42 CFR 84.1152 - Silica dust loading test; respirators designed as protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... cubic meter and against radionuclides; minimum requirements. 84.1152 Section 84.1152 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH... 42 Public Health 1 2011-10-01 2011-10-01 false Silica dust loading test; respirators designed as...

  15. 42 CFR 84.1152 - Silica dust loading test; respirators designed as protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cubic meter and against radionuclides; minimum requirements. 84.1152 Section 84.1152 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH... 42 Public Health 1 2010-10-01 2010-10-01 false Silica dust loading test; respirators designed as...

  16. 42 CFR 84.1152 - Silica dust loading test; respirators designed as protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cubic meter and against radionuclides; minimum requirements. 84.1152 Section 84.1152 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH... 42 Public Health 1 2012-10-01 2012-10-01 false Silica dust loading test; respirators designed as...

  17. 42 CFR 84.1152 - Silica dust loading test; respirators designed as protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... cubic meter and against radionuclides; minimum requirements. 84.1152 Section 84.1152 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH... 42 Public Health 1 2014-10-01 2014-10-01 false Silica dust loading test; respirators designed as...

  18. 76 FR 12648 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-08

    ... be appropriate to use on a short-term basis. 13. The proposed rule addresses (1) which occupations... for respirable coal mine dust, provide for full- shift sampling, redefine the term ``normal production... respect to their availability. If shorter or longer timeframes are recommended, please provide the...

  19. Respiratory health effects of occupational exposure to charcoal dust in Namibia

    PubMed Central

    Kgabi, Nnenesi

    2016-01-01

    Background Charcoal processing activities can increase the risk of adverse respiratory outcomes. Objective To determine dose–response relationships between occupational exposure to charcoal dust, respiratory symptoms and lung function among charcoal-processing workers in Namibia. Methods A cross-sectional study was conducted with 307 workers from charcoal factories in Namibia. All respondents completed interviewer-administered questionnaires. Spirometry was performed, ambient and respirable dust levels were assessed in different work sections. Multiple logistic regression analysis estimated the overall effect of charcoal dust exposure on respiratory outcomes, while linear regression estimated the exposure-related effect on lung function. Workers were stratified according to cumulative dust exposure category. Results Exposure to respirable charcoal dust levels was above occupational exposure limits in most sectors, with packing and weighing having the highest dust exposure levels (median 27.7 mg/m3, range: 0.2–33.0 for the 8-h time-weighted average). The high cumulative dust exposure category was significantly associated with usual cough (OR: 2.1; 95% CI: 1.1–4.0), usual phlegm (OR: 2.1; 95% CI: 1.1–4.1), episodes of phlegm and cough (OR: 2.8; 95% CI: 1.1–6.1), and shortness of breath. A non-statistically significant lower adjusted mean-predicted % FEV1 was observed (98.1% for male and 95.5% for female) among workers with greater exposure. Conclusions Charcoal dust levels exceeded the US OSHA recommended limit of 3.5 mg/m3 for carbon-black-containing material and study participants presented with exposure-related adverse respiratory outcomes in a dose–response manner. Our findings suggest that the Namibian Ministry of Labour introduce stronger enforcement strategies of existing national health and safety regulations within the industry. PMID:27687528

  20. An evaluation of the GCA respirable dust monitor 101-1.

    PubMed

    Marple, V A; Rubow, K L

    1978-01-01

    The GCA RDM 101-1 has been evaluated using aerosols of coal, Arizona road dust, silica, potash, and rock (copper ore) particles. The effects of the dust mass concentration, particle size distribution, and dust material on the instrument response were investigated. The instrument was found to measure the mass concentrations of respirable dust aerosols up to about 16 mg/m3 for coal and rock dust and about 20 mg/m3 for silica, potash, and Arizona road dust, providing there is not appreciable mass in the size range below approximateley 0.7 micrometer aerodynamic diameter.

  1. Systematic on-site monitoring of compliance dust samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grayson, R.L.; Gandy, J.R.

    1996-12-31

    Maintaining compliance with U.S. respirable coal mine dust standards can be difficult on high-productivity longwall panels. Comprehensive and systematic analysis of compliance dust sample data, coupled with access to the U.S. Bureau of Mines (USBM) DUSTPRO, can yield important information for use in maintaining compliance. The objective of this study was to develop and apply a customized software for the collection, storage, modification, and analysis of respirable dust data while providing for flexible export of data and linking with the USBM`s expert advisory system on dust control. An executable, IBM-compatible software was created and customized for use by the personmore » in charge of collecting, submitting, analyzing, and monitoring respirable dust compliance samples. Both descriptive statistics and multiple regression analysis were incorporated. The software allows ASCH files to be exported and directly links with DUSTPRO. After development and validation of the software, longwall compliance data from two different mines was analyzed to evaluate the value of the software. Data included variables on respirable dust concentration, tons produced, the existence of roof/floor rock (dummy variable), and the sampling cycle (dummy variables). Because of confidentiality, specific data will not be presented, only the equations and ANOVA tables. The final regression models explained 83.8% and 61.1% of the variation in the data for the two panels. Important correlations among variables within sampling cycles showed the value of using dummy variables for sampling cycles. The software proved flexible and fast for its intended use. The insights obtained from use improved the systematic monitoring of respirable dust compliance data, especially for pinpointing the most effective dust control methods during specific sampling cycles.« less

  2. NTP Toxicity Study Report on the atmospheric characterization, particle size, chemical composition, and workplace exposure assessment of cellulose insulation (CELLULOSEINS).

    PubMed

    Morgan, Daniel L

    2006-08-01

    Cellulose insulation (CI) is a type of thermal insulation produced primarily from recycled newspapers. The newspapers are shredded, milled, and treated with fire-retardant chemicals. The blowing process for installing CI generates a significant quantity of airborne material that presents a potential inhalation hazard to workers. CI was selected for study based upon the high production volume, the potential for widespread human exposure, and a lack of toxicity data; insufficient information was available to determine whether inhalation studies in laboratory animals were technically feasible or necessary. Studies were conducted to characterize the chemical and physical properties of CI aerosols, to evaluate the potential acute pulmonary toxicity of CI, and to assess occupational exposure of CI installers. Workplace exposure assessments were conducted in collaboration with the National Institute for Occupational Safety and Health (NIOSH, 2001). Chemical analyses were performed on samples of bulk CI from four major United States manufacturers. All samples of the bulk CI were found to contain primarily amorphous cellulose (60% to 65%) with a smaller crystalline component (35% to 40%). The crystalline phase was primarily native cellulose (75% to 85%) with a minor amount of cellulose nitrate (15% to 25%). Elemental analyses of acid digests of CI materials indicated that the major components (>0.1% by weight) included aluminum, boron, calcium, sodium, and sulfur. An acid-insoluble residue present in all four materials (3% to 5% of original sample weight) was found to consist primarily of aluminum silicate hydroxide (kaolinite; approximately 85%) with minor amounts (<5% each) of magnesium silicate hydroxide (talc), potassium aluminum silicate hydroxide (muscovite), and titanium oxide (rutile). Solvent extracts of the bulk materials were analyzed for organic components by gas chromatography with flame ionization detection. Analyses revealed a mass of poorly resolved peaks. Because of the very low concentrations, further quantitative and qualitative analyses were not performed. An aerosol generation system was designed to separate CI particles based upon aerodynamic size and to simulate the process used during CI installation at work sites. Less than 0.1% of each of the CI samples was collected as the small respirable particle fraction. The mean equivalent diameter of respirable particles ranged from 0.6 to 0.7 mum. The numbers of fibers in the respirable fractions ranged from 9.7 x 103 to 1.4 x 106 fibers/g of CI. The respirable particle fractions did not contain cellulose material and consisted mainly of fire retardants and small quantities of clays. The respirable fraction from one CI sample was administered by intratracheal instillation to male Fischer 344 rats at doses of 0, 0.625, 1.25, 2.5, 5, or 10 mg/kg body weight; the bronchoalveolar lavage (BAL) fluid cellularity was evaluated 3 days later. Based upon the relatively mild severity of the inflammatory response, a dose of 5 mg/kg body weight was selected for use in a subsequent 28-day study. Rats received CI, titanium dioxide (particle controls), or sterile saline (controls). BAL fluid was evaluated 1, 3, 7, 14, and 28 days after instillation, and lung histopathology was evaluated 14 and 28 days after treatment. CI caused a greater influx of inflammatory cells than titanium dioxide and caused significant increases in BAL fluid protein and lactate dehydrogenase. These CI-induced changes in BAL fluid parameters were transient and by day 14 were not significantly different than those observed in rats treated with titanium dioxide or phosphate-buffered saline. Unlike titanium dioxide, CI treatment caused a minimal to mild nonprogressive, minimally fibrosing granulomatous pneumonitis characterized by nodular foci of macrophages and giant cells. These results indicated that few respirable particles or fibers are likely generated during the CI application and that the acute pulmonary toxicity is minimal. The CI exposure assessment was conducted with 10 contractors located across the United States. Air samples of total dust and respirable dust were collected for scanning electron microscopy (SEM) to characterize any fibers in the dust. Two SEM air samples for each day of CI activities were collected from the installer and hopper operator. Bulk CI samples were collected and analyzed for metal, boron, and sulfate content. Real-time and video exposure monitoring was conducted to further characterize the CI dust and workers' exposures. The exposure assessment also included a medical component. Investigators collected 175 personal breathing zone (PBZ) total dust, 106 area total dust, and 90 area respirable dust air samples during CI-related activities at the 10 contractor sites. Twenty-six employees' total dust 8-hour time-weighted averages (TWAs) exceeded the Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 15 mg/m3, and 42 exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold-limit value (TLV) of 10 mg/m3. Respirable dust air sampling and real-time monitoring with particle size discrimination indicated low levels of respirable dust generation. The SEM analyses revealed that fibers were an average 28 mum in length and ranged from 5 mum to 150 mum. CI installers' PBZ total dust, area total dust, and area respirable dust air samples were all significantly higher during dry attic applications than wet attic applications (P<0.01). Conversely, the hopper operators' total dust exposures were significantly higher during wet wall and ceiling applications than dry wall and ceiling applications (P=0.02). Analyses of variance tests revealed that exposure concentrations in total dust air samples collected in the PBZ of all CI workers, including installers working in attics, installers during wall applications, hopper operators during attic applications, and hopper operators during wall and ceiling applications, varied significantly during dry applications (P<0.01). The respirable dust air samples collected in attic areas, hopper areas during attic applications, and hopper areas during wall and ceiling applications also differed significantly during dry applications (P=0.03). Twenty-three workers participated in the medical phase of the investigation. The workers completed medical and work history questionnaires, performed serial peak flow tests, and completed multiple acute symptom surveys. The medical questionnaires indicated respiratory, nasal, and skin symptoms that employees attributed to CI exposure. The most common symptoms reported while working with CI included nasal symptoms (35%), eye symptoms (35%), and morning phlegm production (25%). There was a temporal association between CI exposure and eye symptoms, but there was little evidence of lower respiratory system health conditions associated with CI exposure. Chemical analyses of the four bulk CI samples revealed only minor differences in additives. The major elemental components detected were aluminum, boron, calcium, sodium, and sulfur, but they were attributed to the fire retardants aluminum sulfate, boric acid, and sodium sulfate. For all four CI samples, less than 0.1% by weight was collected as the small respirable particle fraction. The fractions consisted mainly of fire retardants and smaller quantities of clays and did not contain cellulose material. Intratracheal instillation of the respirable fraction in rats produced minimal to mild inflammatory responses in the lungs with no increase in severity by 28 days after dosage. Although a significant increase in lung collagen was detected at day 28 in treated rats, microscopic evaluation revealed only a minimal to mild increase in collagen fibrils associated with granulomatous nodules. The results of these studies indicated that few respirable particles or fibers are generated during the aerosolization of CI, and that even at very high doses of respirable CI particles, acute pulmonary toxicity is minimal. These results are supported by the NIOSH workplace exposure assessment conducted on CI workers. Based on the air sample data collected from the 10 contractor site visits, there is a potential for overexposure to CI; however, respirable dust concentrations were typically low. There was increased potential for 8-hour TWAs exceeding the OSHA PEL for total and respirable dust when employees were involved in CI application activities for longer periods of time. There was evidence of work-related eye and mucous membrane irritation among some workers, which were possibly caused by the additives present in CI, such as boric acid. There was little evidence of lower respiratory system health conditions associated with CI exposure. Based upon the results of the CI chemical characterization studies, the pulmonary toxicity study, and the worksite exposure assessment, the NTP concluded that additional studies of CI in laboratory animals are not warranted at this time. However, the animal pulmonary toxicity studies and worker health surveys focused on acute CI exposures and do not preclude the possibility of toxicity resulting from chronic exposure. Although exposure concentrations of respirable CI particulate matter were low, additional information is needed on the biodurability and reactivity of CI particles and fibers in the respiratory tract. CI should continue to be regarded as a nuisance dust, and workers should continue to wear protective masks to prevent inhalation exposure to CI dusts.

  3. Assessment of respirable dust exposures in an opencast coal mine.

    PubMed

    Onder, M; Yigit, E

    2009-05-01

    All major opencast mining activities produce dust. The major operations that produce dust are drilling, blasting, loading, unloading, and transporting. Dust not only deteriorates the environmental air quality in and around the mining site but also creates serious health hazards. Therefore, assessment of dust levels that arise from various opencast mining operations is required to prevent and minimize the health risks. To achieve this objective, an opencast coal mining area was selected to generate site-specific emission data and collect respirable dust measurement samples. The study covered various mining activities in different locations including overburden loading, stock yard, coal loading, drilling, and coal handling plant. The dust levels were examined to assess miners' exposure to respirable dust in each of the opencast mining areas from 1994 to 2005. The data obtained from the dust measurement studies were evaluated by using analysis of variance (ANOVA) and the Tukey-Kramer procedure. The analyses were performed by using Minitab 14 statistical software. It was concluded that, drilling operations produce higher dust concentration levels and thus, drill operators may have higher incidence of respiratory disorders related to exposure to dust in their work environment.

  4. [Dust concentration analysis in non-coal mining. Exposure evaluation based on measurements performed by occupational hygiene laboratories in the years 2001-2005 in Poland].

    PubMed

    Bujak-Pietrek, Stella; Mikołajczyk, Urszula; Szadkowska-Stańczyk, Irena

    2011-01-01

    Non-coal mining includes the extraction of materials for construction (stone, gravel, sand and clay), chemical industry (salt and sulfur), metallurgy (metal ores, uranium and thorium) and other mining and quarrying. Regardless of the type of mining company one of the most common health hazards in this sector is exposure to high concentrations of dust occurring during the extraction of materials. Such activities as drilling, use of blasting agents, processing of raw material, its transportation and loading are the source of large amounts of dust containing crystalline silica. Data on exposure to dust, collected by industrial hygiene laboratories on the basis of dust concentration measurements in the work environment, were obtained from the sanitary inspection service. The analysis of dust concentrations at workplaces in non-coal mining covered the years 2001-2005. The average concentration of inhalable and respirable dust and the degree of results dispersion at workposts in different branches of non-coal mining (according to NACE rev1.1) were evaluated. Also there was estimated the percentage of surveys indicating dust concentrations above hygiene standards. Almost 5000 measurements of dust concentrations were performed in the years under study. The highest concentration of inhalable dust was noted for the production of salt (5.51 mg/m3), other mining and quarrying (4.30 mg/m3) and quarrying of slate (3.77 mg/m3). For respirable dust the highest concentrations were noted in other mining and quarrying (1.10 mg/m3), quarrying of slate (1.09 mg/m3) and quarrying of stone (0.81 mg/m3). Exposure to high concentrations of dust during the extraction of non-carbon is still an important hazard to human health. Almost for all workposts under study the excess of hygiene standards were observed.

  5. Characterization of airborne float coal dust emitted during continuous mining, longwall mining and belt transport

    PubMed Central

    Shahan, M.R.; Seaman, C.E.; Beck, T.W.; Colinet, J.F.; Mischler, S.E.

    2017-01-01

    Float coal dust is produced by various mining methods, carried by ventilating air and deposited on the floor, roof and ribs of mine airways. If deposited, float dust is re-entrained during a methane explosion. Without sufficient inert rock dust quantities, this float coal dust can propagate an explosion throughout mining entries. Consequently, controlling float coal dust is of critical interest to mining operations. Rock dusting, which is the adding of inert material to airway surfaces, is the main control technique currently used by the coal mining industry to reduce the float coal dust explosion hazard. To assist the industry in reducing this hazard, the Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health initiated a project to investigate methods and technologies to reduce float coal dust in underground coal mines through prevention, capture and suppression prior to deposition. Field characterization studies were performed to determine quantitatively the sources, types and amounts of dust produced during various coal mining processes. The operations chosen for study were a continuous miner section, a longwall section and a coal-handling facility. For each of these operations, the primary dust sources were confirmed to be the continuous mining machine, longwall shearer and conveyor belt transfer points, respectively. Respirable and total airborne float dust samples were collected and analyzed for each operation, and the ratio of total airborne float coal dust to respirable dust was calculated. During the continuous mining process, the ratio of total airborne float coal dust to respirable dust ranged from 10.3 to 13.8. The ratios measured on the longwall face were between 18.5 and 21.5. The total airborne float coal dust to respirable dust ratio observed during belt transport ranged between 7.5 and 21.8. PMID:28936001

  6. [Occupational exposure to silica dust by selected sectors of national economy in Poland based on electronic database].

    PubMed

    Bujak-Pietrek, Stella; Mikołajczyk, Urszula; Szadkowska-Stańczyk, Irena; Stroszejn-Mrowca, Grazyna

    2008-01-01

    To evaluate occupational exposure to dusts, the Nofer Institute of Occupational Medicine in Łódź, in collaboration with the Chief Sanitary Inspectorate, has developed the national database to store the results of routine dust exposure measurements performed by occupational hygiene and environmental protection laboratories in Poland in the years 2001-2005. It was assumed that the collected information will be useful in analyzing workers' exposure to free crystalline silica (WKK)-containing dusts in Poland, identyfing exceeded hygiene standards and showing relevant trends, which illustrate the dynamics of exposure in the years under study. Inhalable and respirable dust measurement using personal dosimetry were done according to polish standard PN-91/Z-04030/05 and PN-91/Z-04030/06. In total, 148 638 measurement records, provided by sanitary inspection services from all over Poland, were entered into the database. The database enables the estimation of occupational exposure to dust by the sectors of national economy, according to the Polish Classification of Activity (PKD) and by kinds of dust. The highest exposure level of inhalable and respirable dusts was found in coal mining. Also in this sector, almost 60% of surveys demonstrated exceeded current hygiene standards. High concentrations of both dust fractions (inhalable and respirable) and a considerable percentage of measurements exceeding hygiene standards were found in the manufacture of transport equipment (except for cars), as well as in the chemical, mining (rock, sand, gravel, clay mines) and construction industries. The highest percentage of surveys (inhalable and respirable dust) showing exceeded hygiene standards were observed for coal dust with different content of crystalline silica, organic dust containing more than 10% of SiO2, and highly fibrosis dust containing more than 50% of SiO2.

  7. Effective Dust Control Systems on Concrete Dowel Drilling Machinery

    PubMed Central

    Echt, Alan S.; Sanderson, Wayne T.; Mead, Kenneth R.; Feng, H. Amy; Farwick, Daniel R.; Farwick, Dawn Ramsey

    2016-01-01

    Rotary-type percussion dowel drilling machines, which drill horizontal holes in concrete pavement, have been documented to produce respirable crystalline silica concentrations above recommended exposure criteria. This places operators at potential risk for developing health effects from exposure. United States manufacturers of these machines offer optional dust control systems. The effectiveness of the dust control systems to reduce respirable dust concentrations on two types of drilling machines was evaluated under controlled conditions with the machines operating inside large tent structures in an effort to eliminate secondary exposure sources not related to the dowel-drilling operation. Area air samples were collected at breathing zone height at three locations around each machine. Through equal numbers of sampling rounds with the control systems randomly selected to be on or off, the control systems were found to significantly reduce respirable dust concentrations from a geometric mean of 54 mg per cubic meter to 3.0 mg per cubic meter on one machine and 57 mg per cubic meter to 5.3 mg per cubic meter on the other machine. This research shows that the dust control systems can dramatically reduce respirable dust concentrations by over 90% under controlled conditions. However, these systems need to be evaluated under actual work conditions to determine their effectiveness in reducing worker exposures to crystalline silica below hazardous levels. PMID:27074062

  8. Elemental properties of copper slag and measured airborne exposures at a copper slag processing facility.

    PubMed

    Mugford, Christopher; Gibbs, Jenna L; Boylstein, Randy

    2017-08-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of abrasives containing >1% silica, giving rise to abrasive substitutes like copper slag. We present results from a National Institute for Occupational Safety and Health industrial hygiene survey at a copper slag processing facility that consisted of the collection of bulk samples for metals and silica; and full-shift area and personal air samples for dust, metals, and respirable silica. Carcinogens, suspect carcinogens, and other toxic elements were detected in all bulk samples, and area and personal air samples. Area air samples identified several areas with elevated levels of inhalable and respirable dust, and respirable silica: quality control check area (236 mg/m 3 inhalable; 10.3 mg/m 3 respirable; 0.430 mg/m 3 silica), inside the screen house (109 mg/m 3 inhalable; 13.8 mg/m 3 respirable; 0.686 mg/m 3 silica), under the conveyor belt leading to the screen house (19.8 mg/m 3 inhalable), and inside a conveyor access shack (11.4 mg/m 3 inhalable; 1.74 mg/m 3 respirable; 0.067 mg/m 3 silica). Overall, personal dust samples were lower than area dust samples and did not exceed published occupational exposure limits. Silica samples collected from a plant hand and a laborer exceeded the American Conference of Governmental Industrial Hygienist Threshold Limit Value of 0.025 µg/m 3 . All workers involved in copper slag processing (n = 5) approached or exceeded the Occupational Safety and Health Administration permissible exposure limit of 10 µg/m 3 for arsenic (range: 9.12-18.0 µg/m 3 ). Personal total dust levels were moderately correlated with personal arsenic levels (R s = 0.70) and personal respirable dust levels were strongly correlated with respirable silica levels (R s = 0.89). We identified multiple areas with elevated levels of dust, respirable silica, and metals that may have implications for personal exposure at other facilities if preventive measures are not taken. To our knowledge, this is the first attempt to characterize exposures associated with copper slag processing. More in-depth air monitoring and health surveillance is needed to understand occupational exposures and health outcomes in this industry.

  9. Chalk dustfall during classroom teaching: particle size distribution and morphological characteristics.

    PubMed

    Majumdar, Deepanjan; William, S P M Prince

    2009-01-01

    The study was undertaken to examine the nature of particulate chalk dust settled on classroom floor during traditional teaching with dusting and non-dusting chalks on two types of boards viz. rough and smooth. Settling chalk particles were collected for 30 min during teaching in glass Petri plates placed in classrooms within 3 m distance from the teaching boards. Particle size distribution, scanning electron microscopic images of chalk dusts and compressive strength of two types of chalks were tested and evaluated. Results showed that a larger proportion of dusts generated from anti-dusting chalks were of <4.5 and <2.5 microm size on both smooth and rough boards, as compared to dusting chalks. Non-dusting chalks, on an average, produced about 56% and 62% (by volume) of <4.5 microm (respirable) diameter, on rough and smooth boards, respectively, while the corresponding values for dusting chalks were 36% and 45%. Also, on an average, 83% and 94% (by volume) of the particles were <11 microm (thoracic) in case of non-dusting chalks against 61% and 72% for dusting chalks on rough and smooth boards, respectively. Interestingly, taking into account the mass of chalk dust produced per unit time, which was higher in dusting chalks than non dusting chalks, the former was actually producing higher amount of PM <4.5 and <11 particles from both types of boards. Scanning electron microscope images revealed that chalk particles had random shape, although in dusting chalks prevalence of elongated particles was observed, apparently due to the longitudinal breaking of the chalks during writing, which was confirmed during compressive strength testing. We could conclude that dusting chalks could be potentially more harmful than anti dusting chalks, as they produced higher amount of potentially dangerous PM 4.5 and PM 11.

  10. [Analysis and prevention of dust pollution caused by 5 common prosthetic materials].

    PubMed

    Yang, Xiang-Wen; Wei, Bin; Zhu, Cao-Yun; Qian, Liang; Li, Yi-Han

    2017-10-01

    To analyze and evaluate dust pollution in prosthodontic clinic and make proposal for reasonable protection. This study analyzed the particle size, element composition and dust concentration of 5 materials which were commonly used in dental restorations (veneering ceramics, cobalt-chromium alloy, photosensitive plastic, hard base resin, advanced artificial teeth) by using scanning electron microscopy (SEM), X-ray energy dispersive spectrometer(EDS) and dust concentration laser tester, in order to assess the effects of prosthodontic dust posed on medical staff health and put forward reasonable suggestions for prevention and control of dust pollution. The particle size of veneering ceramics, cobalt-chromium alloy, photosensitive plastic, hard base resin and advanced artificial teeth was (2.15±3.00), (33.78±24.33), (7.78±11.86), (31.16±44.35) and (28.45±39.21)μm, respectively. The time weighted average respirable dust concentration of veneering ceramics was 0.393 mg/m 2 which was beyond the scope of national security. Dust pollution is serious in prosthodontic clinic to which we should pay more attention and take appropriate prevention measures.

  11. Replacement of filters for respirable quartz measurement in coal mine dust by infrared spectroscopy.

    PubMed

    Farcas, Daniel; Lee, Taekhee; Chisholm, William P; Soo, Jhy-Charm; Harper, Martin

    2016-01-01

    The objective of this article is to compare and characterize nylon, polypropylene (PP), and polyvinyl chloride (PVC) membrane filters that might be used to replace the vinyl/acrylic co-polymer (DM-450) filter currently used in the Mine Safety and Health Administration (MSHA) P-7 method (Quartz Analytical Method) and the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods 7603 method (QUARTZ in coal mine dust, by IR re-deposition). This effort is necessary because the DM-450 filters are no longer commercially available. There is an impending shortage of DM-450 filters. For example, the MSHA Pittsburgh laboratory alone analyzes annually approximately 15,000 samples according to the MSHA P-7 method that requires DM-450 filters. Membrane filters suitable for on-filter analysis should have high infrared (IR) transmittance in the spectral region 600-1000 cm(-1). Nylon (47 mm, 0.45 µm pore size), PP (47 mm, 0.45 µm pore size), and PVC (47 mm, 5 µm pore size) filters meet this specification. Limits of detection and limits of quantification were determined from Fourier transform infrared spectroscopy (FTIR) measurements of blank filters. The average measured quartz mass and coefficient of variation were determined from test filters spiked with respirable α-quartz following MSHA P-7 and NIOSH 7603 methods. Quartz was also quantified in samples of respirable coal dust on each test filter type using the MSHA and NIOSH analysis methods. The results indicate that PP and PVC filters may replace the DM-450 filters for quartz measurement in coal dust by FTIR. PVC filters of 5 µm pore size seemed to be suitable replacement although their ability to retain small particulates should be checked by further experiment.

  12. Radiation dose to workers due to the inhalation of dust during granite fabrication.

    PubMed

    Zwack, L M; McCarthy, W B; Stewart, J H; McCarthy, J F; Allen, J G

    2014-03-01

    There has been very little research conducted to determine internal radiation doses resulting from worker exposure to ionising radiation in granite fabrication shops. To address this issue, we estimated the effective radiation dose of granite workers in US fabrication shops who were exposed to the maximum respirable dust and silica concentrations allowed under current US regulations, and also to concentrations reported in the literature. Radiation doses were calculated using standard methods developed by the International Commission on Radiological Protection. The calculated internal doses were very low, and below both US occupational standards (50 mSv yr(-1)) and limits applicable to the general public (1 mSv yr(-1)). Workers exposed to respirable granite dust concentrations at the US Occupational Safety and Health Administration (OSHA) respirable dust permissible exposure limit (PEL) of 5 mg m(-3) over a full year had an estimated radiation dose of 0.062 mSv yr(-1). Workers exposed to respirable granite dust concentrations at the OSHA silica PEL and at the American Conference of Governmental Industrial Hygienists Threshold Limit Value for a full year had expected radiation doses of 0.007 mSv yr(-1) and 0.002 mSv yr(-1), respectively. Using data from studies of respirable granite dust and silica concentrations measured in granite fabrication shops, we calculated median expected radiation doses that ranged from <0.001 to 0.101 mSv yr(-1).

  13. 30 CFR 71.100 - Respirable dust standard.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active... shall be measured with an approved sampling device and expressed in terms of an equivalent concentration determined in accordance with § 71.206 (Approved sampling devices; equivalent concentrations). ...

  14. Effective dust control systems on concrete dowel drilling machinery.

    PubMed

    Echt, Alan S; Sanderson, Wayne T; Mead, Kenneth R; Feng, H Amy; Farwick, Daniel R; Farwick, Dawn Ramsey

    2016-09-01

    Rotary-type percussion dowel drilling machines, which drill horizontal holes in concrete pavement, have been documented to produce respirable crystalline silica concentrations above recommended exposure criteria. This places operators at potential risk for developing health effects from exposure. United States manufacturers of these machines offer optional dust control systems. The effectiveness of the dust control systems to reduce respirable dust concentrations on two types of drilling machines was evaluated under controlled conditions with the machines operating inside large tent structures in an effort to eliminate secondary exposure sources not related to the dowel-drilling operation. Area air samples were collected at breathing zone height at three locations around each machine. Through equal numbers of sampling rounds with the control systems randomly selected to be on or off, the control systems were found to significantly reduce respirable dust concentrations from a geometric mean of 54 mg per cubic meter to 3.0 mg per cubic meter on one machine and 57 mg per cubic meter to 5.3 mg per cubic meter on the other machine. This research shows that the dust control systems can dramatically reduce respirable dust concentrations by over 90% under controlled conditions. However, these systems need to be evaluated under actual work conditions to determine their effectiveness in reducing worker exposures to crystalline silica below hazardous levels.

  15. Measurement of Lung Cancer Tumor Markers in a Glass Wool Company Workers Exposed to Respirable Synthetic Vitreous Fiber and Dust.

    PubMed

    Abtahi, Shabnam; Malekzadeh, Mahyar; Nikravan, Ghafour; Ghaderi, Abbas

    2018-01-01

    Occupational exposures to respirable synthetic vitreous fiber (SVF) and dust are associated with many lung diseases including lung cancer. Low-dose computed tomography is used for screening patients who are highly suspicious of having lung carcinoma. However, it seems not to be cost-effective. Serum biomarkers could be a useful tool for the surveillance of occupational exposure, by providing the possibility of diagnosing lung cancer in its early stages. To determine if serum carcinoembryonic antigen (CEA) and cytokeratin fragment (CYFRA) 21-1 levels in workers exposed more than normal population to respirable SVF and dust may be used as indicators of progression towards lung cancer. An analytic cross-sectional study, including 145 personnel of a glass wool company, along with 25 age-matched healthy individuals, was conducted to investigate the relationship between occupational exposure to respirable SVFs and dust and serum levels of two lung/pleura serum tumor markers, CEA and CYFRA 21-1, measured by ELISA. Individuals exposed to higher than the recommended levels of respirable SVF had higher serum concentrations of CEA and CYFRA 21-1, compared to controls (p=0.008 and 0.040, respectively), as well as in comparison to those exposed to lower than recommended OSHA levels (p=0.046 and 0.033, respectively). Workers with >9 years work experience, had significantly (p=0.045) higher levels of serum CYFRA 21-1 than those with ≤9 years of experience. It seems that working for >9 years in sites with detectable levels of respirable SVF and dust would increase the levels of known lung cancer serum tumor markers. Transferring these workers to sites with respirable SVF concentrations lower than the limit of detection in the air is recommended.

  16. The Effects of Bit Wear on Respirable Silica Dust, Noise and Productivity: A Hammer Drill Bench Study.

    PubMed

    Carty, Paul; Cooper, Michael R; Barr, Alan; Neitzel, Richard L; Balmes, John; Rempel, David

    2017-07-01

    Hammer drills are used extensively in commercial construction for drilling into concrete for tasks including rebar installation for structural upgrades and anchor bolt installation. This drilling task can expose workers to respirable silica dust and noise. The aim of this pilot study was to evaluate the effects of bit wear on respirable silica dust, noise, and drilling productivity. Test bits were worn to three states by drilling consecutive holes to different cumulative drilling depths: 0, 780, and 1560 cm. Each state of bit wear was evaluated by three trials (nine trials total). For each trial, an automated laboratory test bench system drilled 41 holes 1.3 cm diameter, and 10 cm deep into concrete block at a rate of one hole per minute using a commercially available hammer drill and masonry bits. During each trial, dust was continuously captured by two respirable and one inhalable sampling trains and noise was sampled with a noise dosimeter. The room was thoroughly cleaned between trials. When comparing results for the sharp (0 cm) versus dull bit (1560 cm), the mean respirable silica increased from 0.41 to 0.74 mg m-3 in sampler 1 (P = 0.012) and from 0.41 to 0.89 mg m-3 in sampler 2 (P = 0.024); levels above the NIOSH recommended exposure limit of 0.05 mg m-3. Likewise, mean noise levels increased from 112.8 to 114.4 dBA (P < 0.00001). Drilling productivity declined with increasing wear from 10.16 to 7.76 mm s-1 (P < 0.00001). Increasing bit wear was associated with increasing respirable silica dust and noise and reduced drilling productivity. The levels of dust and noise produced by these experimental conditions would require dust capture, hearing protection, and possibly respiratory protection. The findings support the adoption of a bit replacement program by construction contractors. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  17. Variability in quartz exposure in the construction industry: implications for assessing exposure-response relations.

    PubMed

    Tjoe Nij, Evelyn; Höhr, Doris; Borm, Paul; Burstyn, Igor; Spierings, Judith; Steffens, Friso; Lumens, Mieke; Spee, Ton; Heederik, Dick

    2004-03-01

    The aims of this study were to determine implications of inter- and intraindividual variation in exposure to respirable (quartz) dust and of heterogeneity in dust characteristics for epidemiologic research in construction workers. Full-shift personal measurements (n = 67) from 34 construction workers were collected. The between-worker and day-to-day variances of quartz and respirable dust exposure were estimated using mixed models. Heterogeneity in dust characteristics was evaluated by electron microscopic analysis and electron spin resonance. A grouping strategy based on job title resulted in a 2- and 3.5-fold reduction in expected attenuation of a hypothetical exposure-response relation for respirable dust and quartz exposure, respectively, compared to an individual based approach. Material worked on explained most of the between-worker variance in respirable dust and quartz exposure. However, for risk assessment in epidemiology, grouping workers based on the materials they work on is not practical. Microscopic characterization of dust samples showed large quantities of aluminum silicates and large quantities of smaller particles, resulting in a D(50) between 1 and 2 microm. For risk analysis, job title can be used to create exposure groups, although error is introduced by the heterogeneity of dust produced by different construction workers activities and by the nonuniformity of exposure groups. A grouping scheme based on materials worked on would be superior, for both exposure and risk assessment, but is not practical when assessing past exposure. In dust from construction sites, factors are present that are capable of influencing the toxicological potency.

  18. 30 CFR 74.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... respirable dust in coal mine atmospheres that meets the requirements specified under Subpart B of this part... concentrations of respirable dust in coal mine atmospheres that reports within-shift and end-of shift... homogeneous atmosphere about the mean of the population of measurements, divided by the mean at a given...

  19. 30 CFR 74.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... respirable dust in coal mine atmospheres that meets the requirements specified under Subpart B of this part... concentrations of respirable dust in coal mine atmospheres that reports within-shift and end-of shift... homogeneous atmosphere about the mean of the population of measurements, divided by the mean at a given...

  20. 30 CFR 74.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... respirable dust in coal mine atmospheres that meets the requirements specified under Subpart B of this part... concentrations of respirable dust in coal mine atmospheres that reports within-shift and end-of shift... homogeneous atmosphere about the mean of the population of measurements, divided by the mean at a given...

  1. 30 CFR 74.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... respirable dust in coal mine atmospheres that meets the requirements specified under Subpart B of this part... concentrations of respirable dust in coal mine atmospheres that reports within-shift and end-of shift... homogeneous atmosphere about the mean of the population of measurements, divided by the mean at a given...

  2. 30 CFR 71.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...

  3. 30 CFR 90.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operator. 90.209 Section 90.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE... cassette to: Respirable Dust Processing Laboratory, Pittsburgh Safety and Health Technology Center, Cochran...

  4. 30 CFR 71.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...

  5. 30 CFR 71.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...

  6. 30 CFR 90.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator. 90.209 Section 90.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE... cassette to: Respirable Dust Processing Laboratory, Pittsburgh Safety and Health Technology Center, Cochran...

  7. 30 CFR 90.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operator. 90.209 Section 90.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE... cassette to: Respirable Dust Processing Laboratory, Pittsburgh Safety and Health Technology Center, Cochran...

  8. [Amorphous silica. Types, health effects of exposure, NDS].

    PubMed

    Woźniak, H; Wiecek, E

    1995-01-01

    Maximum allowable concentration (MAC) values for amorphous silica dust have not been identified in the Polish legal regulations up-to-date. In this work the authors review values of allowable (recommended) amorphous silica dust concentrations in other countries. Data on other types of amorphous silica (natural and synthetic) used in industry as well as data on health effects of exposure to these types of dust are presented. The work encompasses 42 entries in the references and one Table which includes the following proposed MAC values: Non-calcinate diatomaceous earth (diatomite) and synthetic silica: Total dust--10 mg/m3 Respirable dust--2 mg/m3 Calcinate diatomaceous earth (diatomite) and fused silica (vitreous silica): Total dust--2 mg/m3 Respirable dust--1 mg/m3.

  9. 30 CFR 90.202 - Certified person; sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 90.202 Section 90... Sampling Procedures § 90.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...

  10. 30 CFR 71.202 - Certified person; sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certified person; sampling. 71.202 Section 71... Sampling Procedures § 71.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...

  11. 30 CFR 71.202 - Certified person; sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 71.202 Section 71... Sampling Procedures § 71.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...

  12. 30 CFR 90.202 - Certified person; sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certified person; sampling. 90.202 Section 90... Sampling Procedures § 90.202 Certified person; sampling. (a) The respirable dust sampling required by this... on sampling of respirable coal mine dust. (c) A person may be temporarily certified by MSHA to take...

  13. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  14. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  15. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  16. 42 CFR 84.1142 - Isoamyl acetate tightness test; respirators designed for respiratory protection against dusts...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....1142 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and... 42 Public Health 1 2013-10-01 2013-10-01 false Isoamyl acetate tightness test; respirators...

  17. 42 CFR 84.1142 - Isoamyl acetate tightness test; respirators designed for respiratory protection against dusts...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....1142 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and... 42 Public Health 1 2012-10-01 2012-10-01 false Isoamyl acetate tightness test; respirators...

  18. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  19. 42 CFR 84.1142 - Isoamyl acetate tightness test; respirators designed for respiratory protection against dusts...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....1142 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and... 42 Public Health 1 2011-10-01 2011-10-01 false Isoamyl acetate tightness test; respirators...

  20. 42 CFR 84.1140 - Dust, fume, and mist respirators; performance requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Dust, fume, and mist respirators; performance requirements; general. 84.1140 Section 84.1140 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY...

  1. 42 CFR 84.1142 - Isoamyl acetate tightness test; respirators designed for respiratory protection against dusts...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....1142 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and... 42 Public Health 1 2014-10-01 2014-10-01 false Isoamyl acetate tightness test; respirators...

  2. 42 CFR 84.1142 - Isoamyl acetate tightness test; respirators designed for respiratory protection against dusts...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....1142 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and... 42 Public Health 1 2010-10-01 2010-10-01 false Isoamyl acetate tightness test; respirators...

  3. Exposure to Fibres, Crystalline Silica, Silicon Carbide and Sulphur Dioxide in the Norwegian Silicon Carbide Industry

    PubMed Central

    Føreland, S.; Bye, E.; Bakke, B.; Eduard, W.

    2008-01-01

    Objectives: The aim of this study was to assess personal exposure to fibres, crystalline silica, silicon carbide (SiC) and sulphur dioxide in the Norwegian SiC industry. Methods: Approximately 720 fibre samples, 720 respirable dust samples and 1400 total dust samples were collected from randomly chosen workers from the furnace, processing and maintenance departments in all three Norwegian SiC plants. The respirable dust samples were analysed for quartz, cristobalite and non-fibrous SiC content. Approximately 240 sulphur dioxide samples were collected from workers in the furnace department. Results: The sorting operators from all plants, control room and cleaning operators in Plant A and charger, charger/mix and payloader operators in Plant C had a geometric mean (GM) of fibre exposure above the Norwegian occupational exposure limit (OEL) (0.1 fibre cm−3). The cleaner operators in Plant A had the highest GM exposure to respirable quartz (20 μg m−3). The charger/mix operators in Plant C had the highest GM exposure to respirable cristobalite (38 μg m−3) and the refinery crusher operators in Plant A had the highest GM exposure to non-fibrous SiC (0.65 mg m−3). Exposure to the crystalline silica and non-fibrous SiC was generally low and between 0.4 and 2.1% of the measurements exceeded the OELs. The cleaner operators in Plant A had the highest GM exposure to respirable dust (1.3 mg m−3) and total dust (21 mg m−3). GM exposures for respirable dust above the Norwegian SiC industry-specific OEL of 0.5 mg m−3 were also found for refinery crusher operators in all plants and mix, charger, charger/mix and sorting operators in Plant C. Only 4% of the total dust measurements exceeded the OEL for nuisance dust of (10 mg m−3). Exposure to sulphur dioxide was generally low. However, peaks in the range of 10–100 p.p.m. were observed for control room and crane operators in Plants A and B and for charger and charger/mix operators in Plant C. Conclusion: Workers in the SiC industry are exposed to a mixture of several agents including SiC fibres, quartz, cristobalite, non-fibrous SiC and sulphur dioxide. Exposure levels were generally below the current Norwegian OELs; however, high exposure to fibres and respirable dust still occurs in the furnace department. PMID:18550624

  4. Level and distribution of employee exposures to total and respirable wood dust in two Canadian sawmills.

    PubMed

    Teschke, K; Hertzman, C; Morrison, B

    1994-03-01

    Personal respirable (N = 230) and total (N = 237) dust measurements were made in two coastal British Columbia sawmills using a sampling strategy that randomly selected workers from all jobs in the mills over two seasons. Information about job title, department, season, weather conditions, location of the job relative to wood-cutting machines, and control measures also was collected at the time of sampling. Only 16 respirable wood dust samples were above the detection limit of 0.08 mg/m3; all 16 had levels < or = 0.20 mg/m3. Total wood dust concentrations were also low (36% less than the detection limit), with a mean of 0.51 mg/m3, and ranging from < 0.08 to 52 mg/m3. Measurements of exposure taken close to chippers, planers, and multiple saws had the highest total wood dust levels. Sawmill department and booth enclosures also were associated with wood dust concentrations, while local exhaust ventilation and weather conditions were not. Wood dust levels in this study were generally lower than in other studies of this industry, but most sawmill investigations report mean wood dust concentrations lower than those measured in the furniture and cabinetmaking industries, where concerns about wood dust exposures initially were raised.

  5. Exposure to dust and particle-associated 1-nitropyrene of drivers of diesel-powered equipment in underground mining.

    PubMed

    Scheepers, P T J; Micka, V; Muzyka, V; Anzion, R; Dahmann, D; Poole, J; Bos, R P

    2003-07-01

    A field study was conducted in two mines in order to determine the most suitable strategy for ambient exposure assessment in the framework of a European study aimed at validation of biological monitoring approaches for diesel exhaust (BIOMODEM). Exposure to dust and particle-associated 1-nitropyrene (1-NP) was studied in 20 miners of black coal by the long wall method (Czech Republic) and in 20 workers in oil shale mining by the room and pillar method (Estonia). The study in the oil shale mine was extended to include 100 workers in a second phase (main study). In each mine half of the study population worked underground as drivers of diesel-powered trains (black coal) and excavators (oil shale). The other half consisted of workers occupied in various non-diesel production assignments. Exposure to diesel exhaust was studied by measurement of inhalable and respirable dust at fixed locations and by personal air sampling of respirable dust. The ratio of geometric mean inhalable to respirable dust concentration was approximately two to one. The underground/surface ratio of respirable dust concentrations measured at fixed locations and in the breathing zones of the workers was 2-fold or greater. Respirable dust was 2- to 3-fold higher in the breathing zone than at fixed sampling locations. The 1-NP content in these dust fractions was determined by gas chromatography-mass spectrometry/mass spectrometry and ranged from 0.003 to 42.2 ng/m(3) in the breathing zones of the workers. In mine dust no 1-NP was detected. In both mines 1-NP was observed to be primarily associated with respirable particles. The 1-NP concentrations were also higher underground than on the surface (2- to 3-fold in the coal mine and 10-fold or more in the oil shale mine). Concentrations of 1-NP in the breathing zones were also higher than at fixed sites (2.5-fold in the coal mine and 10-fold in the oil shale mine). For individual exposure assessment personal air sampling is preferred over air sampling at fixed sites. This study also suggests that particle-associated 1-NP much better reflects the ambient exposure to diesel exhaust particles than dust concentrations. Therefore, measurement of particle-associated 1-NP is preferred over measurement of dust concentrations by gravimetry, when linking ambient exposure to biomonitoring outcomes such as protein and DNA adducts and excretion of urinary metabolites of genotoxic substances.

  6. Assessment of respirable dust and its free silica contents in different Indian coalmines.

    PubMed

    Mukherjee, Ashit K; Bhattacharya, Sanat K; Saiyed, Habibullah N

    2005-04-01

    Assessment of respirable dust, personal exposures of miners and free silica contents in dust were undertaken to find out the associated risk of coal workers' pneumoconiosis in 9 coal mines of Eastern India during 1988-91. Mine Research Establishment (MRE), 113A Gravimetric Dust Sampler (GDS) and personal samplers (AFC 123), Cassella, London, approved by Director General of Mines Safety (DGMS) were used respectively for monitoring of mine air dust and personal exposures of miners. Fourier Transform Infra-red (FTIR) Spectroscopy determined free silica in respirable dusts. Thermal Conditions like Wet Bulb Globe Temperature (WBGT) index, humidity and wind velocity were also recorded during monitoring. The dust levels in the face return air of both, Board & Pillar (B&P) and Long Wall (LW) mining were found above the permissible level recommended by DGMS, Govt. of India. The drilling, blasting and loading are the major dusty operations in B&P method. Exposures of driller and loader were varied between, 0.81-9.48 mg/m3 and 0.05-9.84 mg/m3 respectively in B&P mining, whereas exposures of DOSCO loader, Shearer operator and Power Support Face Worker were varied between 2.65-9.11 mg/m3, 0.22-10.00 mg/m3 and 0.12-9.32 mg/m3 respectively in LW mining. In open cast mining, compressor and driller operators are the major exposed groups. The percentage silica in respirable dusts found below 5% in all most all the workers except among query loaders and drillers of open cast mines.

  7. 29 CFR 1926.55 - Gases, vapors, fumes, dusts, and mists.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Nitrous oxide 10024-97-2 E Octachloronaphthalene 2234-13-1 — 0.1 X Octane 111-65-9 400 1900 — Oil mist... — Uranium (as U) 7440-61-1 Soluble compounds — 0.2 — Insoluble compounds — 0.2 — Vanadium 1314-62-1 Respirable dust (as V2 O5) — (C)0.5 — Fume (as V2 O5) — (C)0.1 — Vegetable oil mist Total dust — — Respirable...

  8. 29 CFR 1926.55 - Gases, vapors, fumes, dusts, and mists.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Nitrous oxide 10024-97-2 E Octachloronaphthalene 2234-13-1 — 0.1 X Octane 111-65-9 400 1900 — Oil mist... — Uranium (as U) 7440-61-1 Soluble compounds — 0.2 — Insoluble compounds — 0.2 — Vanadium 1314-62-1 Respirable dust (as V2 O5) — (C)0.5 — Fume (as V2 O5) — (C)0.1 — Vegetable oil mist Total dust — — Respirable...

  9. 29 CFR 1926.55 - Gases, vapors, fumes, dusts, and mists.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Nitrous oxide 10024-97-2 E Octachloronaphthalene 2234-13-1 — 0.1 X Octane 111-65-9 400 1900 — Oil mist... — Uranium (as U) 7440-61-1 Soluble compounds — 0.2 — Insoluble compounds — 0.2 — Vanadium 1314-62-1 Respirable dust (as V2 O5) — (C)0.5 — Fume (as V2 O5) — (C)0.1 — Vegetable oil mist Total dust — — Respirable...

  10. A pilot study of personal exposure to respirable and inhalable dust during the sanding and sawing of medium density fibreboard (MDF) and soft wood.

    PubMed

    Hursthouse, Andrew; Allan, Fraser; Rowley, Louise; Smith, Frank

    2004-08-01

    A pilot study of production of respirable and inhalable dusts from sawing and sanding medium density fibreboard (MDF) and softwood in a typical cabinet-making workshop produced high but variable exposure levels at the bench and operator position. Exposure levels for the total inhalable fraction (approximately <100 microm) were 6.9-91 mg m(-3) for MDF and 2.5-45 mg m(-3) for softwood. For the respirable fraction (< 10 microm) levels were 0.4-13 mg m(-3) for MDF and 0.4-2.9 mg m(-3) for softwood. These results show significant dust loading is produced in the coarser fraction and that the material used has a significant impact on levels produced. It suggests that fuller evaluation of operator influence of fine dust production is needed and may question the common application of a single inhalable exposure standard for wood dust to all wood working scenarios.

  11. 30 CFR 90.210 - Respirable dust samples; report to operator.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.210 Respirable dust samples; report to operator. (a) The Secretary shall... for voiding any samples; and, (7) The Social Security Number of the part 90 miner. (b) Upon receipt...

  12. 42 CFR 84.1147 - Silica mist test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Silica mist test for dust, fume, and mist respirators; minimum requirements. 84.1147 Section 84.1147 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  13. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  14. 42 CFR 84.1158 - Dust, fume, and mist tests; respirators with filters; minimum requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Dust, fume, and mist tests; respirators with filters; minimum requirements; general. 84.1158 Section 84.1158 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  15. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  16. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  17. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2013-10-01 2013-10-01 false DOP filter test; respirators designed as...

  18. 42 CFR 84.1147 - Silica mist test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Silica mist test for dust, fume, and mist respirators; minimum requirements. 84.1147 Section 84.1147 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  19. 42 CFR 84.1147 - Silica mist test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Silica mist test for dust, fume, and mist respirators; minimum requirements. 84.1147 Section 84.1147 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  20. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2014-10-01 2014-10-01 false DOP filter test; respirators designed as...

  1. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2012-10-01 2012-10-01 false DOP filter test; respirators designed as...

  2. 42 CFR 84.1158 - Dust, fume, and mist tests; respirators with filters; minimum requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Dust, fume, and mist tests; respirators with filters; minimum requirements; general. 84.1158 Section 84.1158 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  3. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  4. 42 CFR 84.1158 - Dust, fume, and mist tests; respirators with filters; minimum requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Dust, fume, and mist tests; respirators with filters; minimum requirements; general. 84.1158 Section 84.1158 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  5. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  6. 42 CFR 84.1147 - Silica mist test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Silica mist test for dust, fume, and mist respirators; minimum requirements. 84.1147 Section 84.1147 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  7. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2010-10-01 2010-10-01 false DOP filter test; respirators designed as...

  8. 42 CFR 84.1158 - Dust, fume, and mist tests; respirators with filters; minimum requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Dust, fume, and mist tests; respirators with filters; minimum requirements; general. 84.1158 Section 84.1158 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  9. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  10. 42 CFR 84.1147 - Silica mist test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Silica mist test for dust, fume, and mist respirators; minimum requirements. 84.1147 Section 84.1147 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  11. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  12. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  13. 42 CFR 84.1158 - Dust, fume, and mist tests; respirators with filters; minimum requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Dust, fume, and mist tests; respirators with filters; minimum requirements; general. 84.1158 Section 84.1158 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES...

  14. 42 CFR 84.1149 - Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements. 84.1149 Section 84.1149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  15. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2011-10-01 2011-10-01 false DOP filter test; respirators designed as...

  16. 42 CFR 84.1146 - Lead fume test for dust, fume, and mist respirators; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Lead fume test for dust, fume, and mist respirators; minimum requirements. 84.1146 Section 84.1146 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  17. Evaluation of occupational exposure to toxic metals released in the process of aluminum welding.

    PubMed

    Matczak, Wanda; Gromiec, Jan

    2002-04-01

    The objective of this study was to evaluate occupational exposure to welding fumes and its elements on aluminum welders in Polish industry. The study included 52 MIG/Al fume samples and 18 TIG/Al samples in 3 plants. Air samples were collected in the breathing zone of welders (total and respirable dust). Dust concentration was determined gravimetrically, and the elements in the collected dust were determined by AAS. Mean time-weighted average (TWA) concentrations of the welding dusts/fumes and their components in the breathing zone obtained for different welding processes were, in mg/m3: MIG/Al fumes mean 6.0 (0.8-17.8), Al 2.1 (0.1-7.7), Mg 0.2 (< 0.1-0.9), Mn 0.014 (0.002-0.049), Cu 0.011 (0.002-0.092), Zn 0.016 (0.002-0.14), Pb 0.009 (0.005-0.025), Cr 0.003 (0.002-0.007), and TIG/Al fumes 0.7 (0.3-1.4), Al 0.17 (0.07-0.50). A correlation has been found between the concentration of the main components and the fume/dust concentrations in MIG/Al and TIG/Al fumes. Mean percentages of the individual components in MIG/Al fumes/dusts were Al: 30 (9-56) percent; Mg: 3 (1-5.6) percent; Mn: 0.2 (0.1-0.3) percent; Cu: 0.2 (< 0.1-1.8) percent; Zn: 0.2 (< 0.1-0.8) percent; Pb: 0.2 (< 0.1-1) percent; Cr: < 0.1 percent. The proportion of the respirable fraction in the fumes and their constituents varied between 10 percent and 100 percent. The results showed that MIG/Al fumes concentration was 1.2 times higher than the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV), and the index of the combined exposure to the determined agents was 2.3 (0.4-8.0), mostly because of high Al2O3 contribution. The background concentrations of the components (ca. 5-10 times lower than those in the breathing zone of the welders) did not exceed the Polish MAC value. The elemental composition of total and respirable fume/dust may differ considerably depending on welding methods, the nature of welding-related operations, and work environment conditions.

  18. Exposures to quartz, diesel, dust, and welding fumes during heavy and highway construction.

    PubMed

    Woskie, Susan R; Kalil, Andrew; Bello, Dhimiter; Virji, M Abbas

    2002-01-01

    Personal samples for exposure to dust, diesel exhaust, quartz, and welding fume were collected on heavy and highway construction workers. The respirable, thoracic, and inhalable fractions of dust and quartz exposures were estimated from 260 personal impactor samples. Respirable quartz exposures exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit (REL) in 7-31% of cases for the trades sampled. More than 50% of the samples in the installation of drop ceilings and wall tiles and concrete finish operations exceeded the NIOSH REL for quartz. Thoracic exposures to quartz and dust exceeded respirable exposures by a factor of 4.5 and 2.8, respectively. Inhalable exposures to quartz and dust exceeded respirable exposures by a factor of 25.6 and 9.3, respectively. These findings are important due to the identification of quartz as a carcinogen by the National Toxicology Program and the International Agency for Research on Cancer. Fourteen percent of the personal samples for EC (n = 261), collected as a marker for diesel exhaust, exceeded the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) for diesel exhaust. Seventeen of the 22 (77%) samples taken during a partially enclosed welding operation reached or exceeded the ACGIH TLV of 5 mg/m3 for welding fume.

  19. Comparative Risks of Cancer from Drywall Finishing Based on Stochastic Modeling of Cumulative Exposures to Respirable Dusts and Chrysotile Asbestos Fibers.

    PubMed

    Boelter, Fred W; Xia, Yulin; Dell, Linda

    2015-05-01

    Sanding joint compounds is a dusty activity and exposures are not well characterized. Until the mid 1970s, asbestos-containing joint compounds were used by some people such that sanding could emit dust and asbestos fibers. We estimated the distribution of 8-h TWA concentrations and cumulative exposures to respirable dusts and chrysotile asbestos fibers for four worker groups: (1) drywall specialists, (2) generalists, (3) tradespersons who are bystanders to drywall finishing, and (4) do-it-yourselfers (DIYers). Data collected through a survey of experienced contractors, direct field observations, and literature were used to develop prototypical exposure scenarios for each worker group. To these exposure scenarios, we applied a previously developed semi-empirical mathematical model that predicts area as well as personal breathing zone respirable dust concentrations. An empirical factor was used to estimate chrysotile fiber concentrations from respirable dust concentrations. On a task basis, we found mean 8-h TWA concentrations of respirable dust and chrysotile fibers are numerically highest for specialists, followed by generalists, DIYers, and bystander tradespersons; these concentrations are estimated to be in excess of the respective current but not historical Threshold Limit Values. Due to differences in frequency of activities, annual cumulative exposures are highest for specialists, followed by generalists, bystander tradespersons, and DIYers. Cumulative exposure estimates for chrysotile fibers from drywall finishing are expected to result in few, if any, mesothelioma or excess lung cancer deaths according to recently published risk assessments. Given the dustiness of drywall finishing, we recommend diligence in the use of readily available source controls. © 2014 Society for Risk Analysis.

  20. Cohort mortality study of North American industrial sand workers. III. Estimation of past and present exposures to respirable crystalline silica.

    PubMed

    Rando, R J; Shi, R; Hughes, J M; Weill, H; McDonald, A D; McDonald, J C

    2001-04-01

    Lung cancer and silicosis mortality were examined longitudinally and by a case-referent analysis in a cohort of workers selected from the North American industrial sand industry. Date of hire in the case-referent sub-cohort extended as far back as the second decade of the twentieth century. The aim of this study component was to develop estimates of average and cumulative exposure to respirable crystalline silica for the 342 selected cases and referents. Process and dust control histories were developed for each plant, and quantitative exposure data obtained from each of them and from a trade organization. An algorithm was developed to convert historical exposures reported in particle count concentrations to modern measures of mass concentration of respirable crystalline silica. Personal exposures were adjusted for use of protective equipment based on frequency of use and type of protection. Between 1974 and 1998, a total of 14249 exposure measurements had been taken using a cyclone and membrane filter and gave an overall geometric mean of 42 microg/m3. The only exposure data identified earlier were based on approximately 500 samples collected across the industry between 1947 and 1955 using the Greenburg-Smith impinger, with analysis by microscopy. These data were converted to modern measures using a factor of 1 mppcf = 276 microg/m3 respirable dust and then adjusting for percentage silica. In general, the highest exposures occurred in bagging and bulk-loading operations and the lowest in wet processing of sand. There has been a substantial decline in exposure levels in this industry over time. The decline was rapid between the 1940s and 1970s and current exposures are, on average, less than 50 microg/m3. The use of personal protective equipment was judged to have had little impact on exposure before the 1970s.

  1. Pulmonary risk of intraoral surface conditioning using crystalline silica.

    PubMed

    Mayer, Beate; Raithel, Hans; Weltle, Dieter; Niedermeier, Wilhelm

    2003-01-01

    This study evaluated the pulmonary risk caused by possible respirable dust of Al2O3 and SiO(x) resulting from chairside tribochemical sandblasting procedures in a dental office. Dust was collected using a trap near the working field, and quantitative morphologic determination and identification were performed with SEM and EDAX. Forty blasting processes (total time 20 minutes) were aimed at a dummy to obtain maximum pollution of the workplace. Respirable dust fraction was measured using personal air samplers with an 8-microm cellulose-nitrate filter and a volume flow rate of 2 L/min. Mass of the respirable dust fraction was determined, and respirable free crystalline silica was identified with the help of infrared spectroscopy. Blasting of metal or ceramic surfaces with tribochemical agents produces respirable and potentially harmful SiO(x) and Al2O3 particles with a diameter of less than 5 microm, showing a total concentration in the air of less than 0.3 mg/m3. With and without dental suction, the concentration of the respirable free crystalline silica was smaller than 0.02 mg/m3. Concern regarding the risk of chairside tribochemical methods and possible impairment of health of patients and dental staff is unfounded, even under extreme conditions or without protective measures, since the concentrations of SiO(x) found in the air of the workplace were far below the current threshold value of 0.15 mg/m3.

  2. 30 CFR 90.301 - Respirable dust control plan; approval by District Manager; copy to part 90 miner.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... District Manager; copy to part 90 miner. 90.301 Section 90.301 Mineral Resources MINE SAFETY AND HEALTH... control plan; approval by District Manager; copy to part 90 miner. (a) The District Manager will approve... District Manager shall consider whether: (1) The respirable dust control measures would be likely to...

  3. Calibrating a Respirable Dust Sampling Device. Module 24. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on calibrating a respirable dust sampling device. Following guidelines for students and instructors and an introduction that explains what the student will learn, are three lessons: (1) naming each part of…

  4. Assessing dust exposure in an integrated iron and steel manufacturing plant in South India.

    PubMed

    Ravichandran, B; Krishnamurthy, V; Ravibabu, K; Raghavan, S; Rajan, B K; Rajmohan, H R

    2008-01-01

    A study to monitor and estimate respirable particulate matter (RPM), toxic trace metal concentrations in the work environment was carried out in different sections of an integrated steel manufacturing industry. The average RPM concentration observed varied according to the section blast furnace was 2.41 mg/m;{3}; energy optimization furnace, 1.87 mg/m;{3}; sintering plant, 0.98 mg/m;{3}; continuous casting machine, 1.93 mg/m;{3}. The average trace metal concentration estimated from the RPM samples like iron, manganese, lead and chromium did not exceed ACGIH prescribed levels.

  5. Variability of the health effects of crystalline silica: Fe speciation in industrial quartz reagents and suspended dusts—insights from XAS spectroscopy

    NASA Astrophysics Data System (ADS)

    Di Benedetto, Francesco; D'Acapito, Francesco; Capacci, Fabio; Fornaciai, Gabriele; Innocenti, Massimo; Montegrossi, Giordano; Oberhauser, Werner; Pardi, Luca A.; Romanelli, Maurizio

    2014-03-01

    We investigated the speciation of Fe in bulk and in suspended respirable quartz dusts coming from ceramic and iron-casting industrial processes via X-ray absorption spectroscopy, with the aim of contributing to a better understanding of the variability of crystalline silica toxicity. Four different bulk industrial quartz powders, nominally pure quartz samples with Fe contents below 200 ppm, and three respirable dusts filters were selected. Fe speciation was determined in all samples through a coupled study of the X-ray absorption near-edge structure and extended X-ray absorption fine structure regions, operating at the Fe-K edge. Fe speciation revealed common features at the beginning of the different production processes, whereas significant differences were observed on both respirable dusts and bulk dusts exiting from the production process. Namely, a common pollution of the raw quartz dusts by elemental Fe was evidenced and attributed to residuals of the industrial production of quartz materials. Moreover, the respirable samples indicated that reactivity occurs after the suspension of the powders in air. The gravitational selection during the particle suspension consistently allowed us to clearly discriminate between suspended and bulk dusts. On the basis of the obtained results, we provide an apparent spectroscopic discrimination between the raw materials used in the considered industrial processes, and those that are effectively inhaled by workers. In particular, an amorphous FeIII oxide, with an unsaturated coordination sphere, can be related to silica reactivity (and health consequences).

  6. Open-air sprays for capturing and controlling airborne float coal dust on longwall faces

    PubMed Central

    Beck, T.W.; Seaman, C.E.; Shahan, M.R.; Mischler, S.E.

    2018-01-01

    Float dust deposits in coal mine return airways pose a risk in the event of a methane ignition. Controlling airborne dust prior to deposition in the return would make current rock dusting practices more effective and reduce the risk of coal-dust-fueled explosions. The goal of this U.S. National Institute for Occupational Safety and Health study is to determine the potential of open-air water sprays to reduce concentrations of airborne float coal dust, smaller than 75 µm in diameter, in longwall face airstreams. This study evaluated unconfined water sprays in a featureless tunnel ventilated at a typical longwall face velocity of 3.6 m/s (700 fpm). Experiments were conducted for two nozzle orientations and two water pressures for hollow cone, full cone, flat fan, air atomizing and hydraulic atomizing spray nozzles. Gravimetric samples show that airborne float dust removal efficiencies averaged 19.6 percent for all sprays under all conditions. The results indicate that the preferred spray nozzle should be operated at high fluid pressures to produce smaller droplets and move more air. These findings agree with past respirable dust control research, providing guidance on spray selection and spray array design in ongoing efforts to control airborne float dust over the entire longwall ventilated opening. PMID:29348700

  7. Open-air sprays for capturing and controlling airborne float coal dust on longwall faces.

    PubMed

    Beck, T W; Seaman, C E; Shahan, M R; Mischler, S E

    2018-01-01

    Float dust deposits in coal mine return airways pose a risk in the event of a methane ignition. Controlling airborne dust prior to deposition in the return would make current rock dusting practices more effective and reduce the risk of coal-dust-fueled explosions. The goal of this U.S. National Institute for Occupational Safety and Health study is to determine the potential of open-air water sprays to reduce concentrations of airborne float coal dust, smaller than 75 µm in diameter, in longwall face airstreams. This study evaluated unconfined water sprays in a featureless tunnel ventilated at a typical longwall face velocity of 3.6 m/s (700 fpm). Experiments were conducted for two nozzle orientations and two water pressures for hollow cone, full cone, flat fan, air atomizing and hydraulic atomizing spray nozzles. Gravimetric samples show that airborne float dust removal efficiencies averaged 19.6 percent for all sprays under all conditions. The results indicate that the preferred spray nozzle should be operated at high fluid pressures to produce smaller droplets and move more air. These findings agree with past respirable dust control research, providing guidance on spray selection and spray array design in ongoing efforts to control airborne float dust over the entire longwall ventilated opening.

  8. Lunar Dust Separation for Toxicology Studies

    NASA Technical Reports Server (NTRS)

    Cooper, Bonnie L.; McKay, D. S.; Riofrio, L. M.; Taylor, L. A.; Gonzalex, C. P.

    2010-01-01

    During the Apollo missions, crewmembers were briefly exposed to dust in the lunar module, brought in after extravehicular activity. When the lunar ascent module returned to micro-gravity, the dust that had settled on the floor now floated into the air, causing eye discomfort and occasional respiratory symptoms. Because our goal is to set an exposure standard for 6 months of episodic exposure to lunar dust for crew on the lunar surface, these brief exposures of a few days are not conclusive. Based on experience with industrial minerals such as sandblasting quartz, an exposure of several months may cause serious damage, while a short exposure may cause none. The detailed characteristics of sub-micrometer lunar dust are only poorly known, and this is the size range of particles that are of greatest concern. We have developed a method for extracting respirable dust (<2.5 micron) from Apollo lunar soils. This method meets stringent requirements that the soil must be kept dry, exposed only to pure nitrogen, and must conserve and recover the maximum amount of both respirable dust and coarser soil. In addition, we have developed a method for grinding coarser lunar soil to produce sufficient respirable soil for animal toxicity testing while preserving the freshly exposed grain surfaces in a pristine state.

  9. Measurement of respirable superabsorbent polyacrylate (SAP) dust by ethanol derivatization using gas chromatography-mass spectrometry (GC-MS) detection.

    PubMed

    McCormack, Paul; Lemmo, John S; Macomber, Margaret; Holcomb, Mark L; Lieckfield, Robert

    2011-04-01

    Superabsorbent polyacrylate (SAP) is an important industrial chemical manufactured primarily as sodium polyacrylate but occasionally as potassium salt. It has many applications owing to its intrinsic physical property of very high water absorption, which can be more than 100 times it own weight. SAP is commonly used in disposable diapers and feminine hygiene products and is known by a number of synonyms-sodium polyacrylate, superabsorbent polyacrylate (SAP), polyacrylate absorbent (PA), and superabsorbent material (SAM). Germany and The Netherlands have adopted a nonbinding scientific guideline value 0.05 mg/m³ (8-hr time-weighted average, TWA) as the maximum allowable workplace concentration for the respirable dust of SAP (<10 μm particle diameter). Three industry associations representing Europe, the United States, and Asia have adopted the German scientific guideline value of 0.05 mg/m³ (8-hr TWA) as a voluntary guideline. A new test method based on alcohol derivatization of the acrylate was developed and validated for the analysis of respirable superabsorbent polyacrylate dust collected on filter cassettes in the workplace environment. This method is an alternative to the commonly used sodium-based method, which is limited owing to potential interference by other sources of sodium from the workplace and laboratory environments. The alcohol derivatization method effectively eliminates sodium interference from several classes of sodium compounds, as shown by their purposeful introduction at two and six times the equivalent amount of SAP present in reference samples. The accuracy of the method, as determined by comparison with sodium analysis of known reference samples, was greater than 80% over the study range of 5-50 μg of SAP dust. The lower reporting limit of the method is 3.0 μg of SAP per sample, which is equivalent to 3 (μg/m³) for an 8-hr sampling period at the recommended flow rate of 2.2 L/min.

  10. Protect Yourself: Respirators

    MedlinePlus

    ... dust masks) can be used for dust, mists, welding fumes, etc. They do not provide protection from ... tion against most vapors, acid gases, dust or welding fumes. Cartridges/filters must match contaminant(s) and be ...

  11. Prevalence of dry methods in granite countertop fabrication in Oklahoma.

    PubMed

    Phillips, Margaret L; Johnson, Andrew C

    2012-01-01

    Granite countertop fabricators are at risk of exposure to respirable crystalline silica, which may cause silicosis and other lung conditions. The purpose of this study was to estimate the prevalence of exposure control methods, especially wet methods, in granite countertop fabrication in Oklahoma to assess how many workers might be at risk of overexposure to crystalline silica in this industry. Granite fabrication shops in the three largest metropolitan areas in Oklahoma were enumerated, and 47 of the 52 shops participated in a survey on fabrication methods. Countertop shops were small businesses with average work forces of fewer than 10 employees. Ten shops (21%) reported using exclusively wet methods during all fabrication steps. Thirty-five shops (74%) employing a total of about 200 workers reported using dry methods all or most of the time in at least one fabrication step. The tasks most often performed dry were edge profiling (17% of shops), cutting of grooves for reinforcing rods (62% of shops), and cutting of sink openings (45% of shops). All shops reported providing either half-face or full-face respirators for use during fabrication, but none reported doing respirator fit testing. Few shops reported using any kind of dust collection system. These findings suggest that current consumer demand for granite countertops is giving rise to a new wave of workers at risk of silicosis due to potential overexposure to granite dust.

  12. The biology of talc.

    PubMed Central

    Hildick-Smith, G Y

    1976-01-01

    Data are presented on the effects on health of talc dusts from exposure in industry and use of talc-containing health products. The mineralogy of talc and the composition of cosmetic and industrial grade talc dusts are described. Studies in animals are reviewed, and epidemiological data are considered in relation to exposures that occur during industrial and consumer uses of talc dusts. Hamsters exposed to 8 mg/m3 of respirable cosmetic grade talc dust for up to 150 minutes a day for 300 consecutive days showed no difference in incidence or nature of pathological lesions from those observed in a group of untreated animals. A retrospective study of the causes of death of 227 talc mine millers exposed to cosmetic grade talc at the threshold limit value for talc (20 million parts per cubic foot) for an average of 15-8 years showed that the causes of death were no different from those in a control cohort not exposed to talc dust. The available data indicate that talc dust exposure in the modern mining of cosmetic grade talc does not appear to be injurious to health. The significantly lower dust exposure in the normal use of cosmetic grade talc dusts in talc-containing health and cosmetic products confirms that their use is not a hazard to health. PMID:793610

  13. The Development and Testing of a Prototype Mini-Baghouse to Control the Release of Respirable Crystalline Silica from Sand Movers

    PubMed Central

    Alexander, Barbara M.; Esswein, Eric J.; Gressel, Michael G.; Kratzer, Jerry L.; Feng, H. Amy; King, Bradley; Miller, Arthur L.; Cauda, Emanuele

    2016-01-01

    Inhalation of respirable crystalline silica (RCS) is a significant risk to worker health during well completions operations (which include hydraulic fracturing) at conventional and unconventional oil and gas extraction sites. RCS is generated by pneumatic transfer of quartz-containing sand during hydraulic fracturing operations. National Institute for Occupational Safety and Health (NIOSH) researchers identified concentrations of RCS at hydraulic fracturing sites that exceed 10 times the Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) and up to 50 times the NIOSH Recommended Exposure Limit (REL). NIOSH research identified at least seven point sources of dust release at contemporary oil and gas extraction sites where RCS aerosols were generated. NIOSH researchers recommend the use of engineering controls wherever they can be implemented to limit the RCS released. A control developed to address one of the largest sources of RCS aerosol generation is the NIOSH mini-baghouse assembly, mounted on the thief hatches on top of the sand mover. This manuscript details the results of a trial of the NIOSH mini-baghouse at a sand mine in Arkansas, November 18 – 21, 2013. During the trial, area air samples were collected at 12 locations on and around a sand mover with and without the mini-baghouse control installed. Analytical results for respirable dust and RCS indicate the use of the mini-baghouse effectively reduced both respirable dust and RCS downwind of the thief hatches. Reduction of airborne respirable dust ranged from 85% to 98%; reductions in airborne RCS ranged from 79% to 99%. A bulk sample of dust collected by the baghouse assembly showed the likely presence of freshly fractured quartz, a particularly hazardous form of RCS. Planned future design enhancements will increase the performance and durability of the mini-baghouse, including an improved bag clamp mechanism and upgraded filter fabric with a modified air-to-cloth ratio. Future trials are planned to determine additional respirable dust and RCS concentration reductions achieved through these design changes. PMID:27003622

  14. Controlling dust from concrete saw cutting.

    PubMed

    Shepherd, Susan; Woskie, Susan

    2013-01-01

    Cutting concrete with gas-powered saws is ubiquitous in the construction industry and a source of exposure to respirable crystalline silica. Volunteers from the New England Laborers Training Center were recruited to participate in a field experiment examining dust reductions through the use of water, from a hose and from a sprayer, as a dust control. In four series of tests, reinforced concrete pipe was cut under both "dry" and "wet" control conditions. Overall, the geometric mean respirable dust concentration for "dry" cutting (14.396 mg/m³) exceeded both types of water-based controls by more than tenfold. Wet cutting reduced the respirable dust concentration by 85% compared with dry cutting when comparing tests paired by person and saw blade (n = 79 pairs). Using a respirable cyclone, a total of 178 samples were taken. Due to the high variability in dust exposure found in this and other studies of saw cutting, the data were examined for potential exposure determinants that contribute to that variability. Using mixed models, three fixed effects were statistically significant: control condition, worker experience, and location. A random effect for subject was included in the model to account for repeated measures. When each of the significant fixed effects was included with the random effect, it was apparent that inclusion of worker experience or location reduced the between-worker component of exposure variability, while inclusion of control condition (wet vs. dry) explained a large portion of the within-subject variability. Overall, the fixed effect variable for control condition explained the largest fraction of the total exposure variability.

  15. Silica dust exposures during selected construction activities.

    PubMed

    Flanagan, Mary Ellen; Seixas, Noah; Majar, Maria; Camp, Janice; Morgan, Michael

    2003-01-01

    This study characterized exposure for dust-producing construction tasks. Eight common construction tasks were evaluated for quartz and respirable dust exposure by collecting 113 personal task period samples for cleanup; demolition with handheld tools; concrete cutting; concrete mixing; tuck-point grinding; surface grinding; sacking and patching concrete; and concrete floor sanding using both time-integrating filter samples and direct-reading respirable dust monitors. The geometric mean quartz concentration was 0.10 mg/m(3) (geometric standard deviation [GSD]=4.88) for all run time samples, with 71% exceeding the threshold limit value. Activities with the highest exposures were surface grinding, tuck-point grinding, and concrete demolition (GM[GSD] of 0.63[4.12], 0.22[1.94], and 0.10[2.60], respectively). Factors recorded each minute were task, tool, work area, respiratory protection and controls used, estimated cross draft, and whether anyone nearby was making dust. Factors important to exposure included tool used, work area configuration, controls employed, cross draft, and in some cases nearby dust. More protective respirators were employed as quartz concentration increased, although respiratory protection was found to be inadequate for 42% of exposures. Controls were employed for only 12% of samples. Exposures were reduced with three controls: box fan for surface grinding and floor sanding, and vacuum/shroud for surface grinding, with reductions of 57, 50, and 71%, respectively. Exposures were higher for sweeping compound, box fan for cleanup, ducted fan dilution, and wetted substrate. Construction masons and laborers are frequently overexposed to silica. The usual protection method, respirators, was not always adequate, and engineering control use was infrequent and often ineffective.

  16. Consideration of Kaolinite Interference Correction for Quartz Measurements in Coal Mine Dust

    PubMed Central

    Lee, Taekhee; Chisholm, William P.; Kashon, Michael; Key-Schwartz, Rosa J.; Harper, Martin

    2015-01-01

    Kaolinite interferes with the infrared analysis of quartz. Improper correction can cause over- or underestimation of silica concentration. The standard sampling method for quartz in coal mine dust is size selective, and, since infrared spectrometry is sensitive to particle size, it is intuitively better to use the same size fractions for quantification of quartz and kaolinite. Standard infrared spectrometric methods for quartz measurement in coal mine dust correct interference from the kaolinite, but they do not specify a particle size for the material used for correction. This study compares calibration curves using as-received and respirable size fractions of nine different examples of kaolinite in the different correction methods from the National Institute for Occupational Safety and Health Manual of Analytical Methods (NMAM) 7603 and the Mine Safety and Health Administration (MSHA) P-7. Four kaolinites showed significant differences between calibration curves with as-received and respirable size fractions for NMAM 7603 and seven for MSHA P-7. The quartz mass measured in 48 samples spiked with respirable fraction silica and kaolinite ranged between 0.28 and 23% (NMAM 7603) and 0.18 and 26% (MSHA P-7) of the expected applied mass when the kaolinite interference was corrected with respirable size fraction kaolinite. This is termed “deviation,” not bias, because the applied mass is also subject to unknown variance. Generally, the deviations in the spiked samples are larger when corrected with the as-received size fraction of kaolinite than with the respirable size fraction. Results indicate that if a kaolinite correction with reference material of respirable size fraction is applied in current standard methods for quartz measurement in coal mine dust, the quartz result would be somewhat closer to the true exposure, although the actual mass difference would be small. Most kinds of kaolinite can be used for laboratory calibration, but preferably, the size fraction should be the same as the coal dust being collected. PMID:23767881

  17. Consideration of kaolinite interference correction for quartz measurements in coal mine dust.

    PubMed

    Lee, Taekhee; Chisholm, William P; Kashon, Michael; Key-Schwartz, Rosa J; Harper, Martin

    2013-01-01

    Kaolinite interferes with the infrared analysis of quartz. Improper correction can cause over- or underestimation of silica concentration. The standard sampling method for quartz in coal mine dust is size selective, and, since infrared spectrometry is sensitive to particle size, it is intuitively better to use the same size fractions for quantification of quartz and kaolinite. Standard infrared spectrometric methods for quartz measurement in coal mine dust correct interference from the kaolinite, but they do not specify a particle size for the material used for correction. This study compares calibration curves using as-received and respirable size fractions of nine different examples of kaolinite in the different correction methods from the National Institute for Occupational Safety and Health Manual of Analytical Methods (NMAM) 7603 and the Mine Safety and Health Administration (MSHA) P-7. Four kaolinites showed significant differences between calibration curves with as-received and respirable size fractions for NMAM 7603 and seven for MSHA P-7. The quartz mass measured in 48 samples spiked with respirable fraction silica and kaolinite ranged between 0.28 and 23% (NMAM 7603) and 0.18 and 26% (MSHA P-7) of the expected applied mass when the kaolinite interference was corrected with respirable size fraction kaolinite. This is termed "deviation," not bias, because the applied mass is also subject to unknown variance. Generally, the deviations in the spiked samples are larger when corrected with the as-received size fraction of kaolinite than with the respirable size fraction. Results indicate that if a kaolinite correction with reference material of respirable size fraction is applied in current standard methods for quartz measurement in coal mine dust, the quartz result would be somewhat closer to the true exposure, although the actual mass difference would be small. Most kinds of kaolinite can be used for laboratory calibration, but preferably, the size fraction should be the same as the coal dust being collected.

  18. Dust generation in powders: Effect of particle size distribution

    NASA Astrophysics Data System (ADS)

    Chakravarty, Somik; Le Bihan, Olivier; Fischer, Marc; Morgeneyer, Martin

    2017-06-01

    This study explores the relationship between the bulk and grain-scale properties of powders and dust generation. A vortex shaker dustiness tester was used to evaluate 8 calcium carbonate test powders with median particle sizes ranging from 2μm to 136μm. Respirable aerosols released from the powder samples were characterised by their particle number and mass concentrations. All the powder samples were found to release respirable fractions of dust particles which end up decreasing with time. The variation of powder dustiness as a function of the particle size distribution was analysed for the powders, which were classified into three groups based on the fraction of particles within the respirable range. The trends we observe might be due to the interplay of several mechanisms like de-agglomeration and attrition and their relative importance.

  19. Pulmonary function in workers exposed to diesel exhausts: the effect of control measures.

    PubMed

    Ulfvarson, U; Alexandersson, R; Dahlqvist, M; Ekholm, U; Bergström, B

    1991-01-01

    To assess the protective effect of exhausts pipe filters or respirators on pulmonary function, 15 workers in a tunnel construction site, truck and loading machine drivers, rock workers, and others were studied. The total and respirable dust, combustible matter in respirable dust, carbon monoxide, nitrogen monoxide and nitrogen dioxide were measured for each subject during entire work shifts. The effect of the exposure on the lung function variables was measured by dynamic spirometry, carbon monoxide single breath technique, and nitrogen single breath wash-out. The exhaust pipe filtering had a protective effect, directly discernible in the drivers on vital capacity and FEV1.0 and for the whole group on FEV% and TLco. The dust respirators had no effect, probably because of the difficulties in correctly using personal protection under the circumstances in the tunnel. In the absence of a true exposure assessment, control measures for diesel exhausts can be tested by medical effect studies. Catalytic particle filters of diesel exhausts are one method of rendering the emissions less irritant, although they will not remove irritant gases. An indicator of diesel exhaust exposure should include the particle fraction of the diesel exhausts, but a discrimination between different sources of organic dust must be possible.

  20. Real-time measurement of dust in the workplace using video exposure monitoring: Farming to pharmaceuticals

    NASA Astrophysics Data System (ADS)

    Walsh, P. T.; Forth, A. R.; Clark, R. D. R.; Dowker, K. P.; Thorpe, A.

    2009-02-01

    Real-time, photometric, portable dust monitors have been employed for video exposure monitoring (VEM) to measure and highlight dust levels generated by work activities, illustrate dust control techniques, and demonstrate good practice. Two workplaces, presenting different challenges for measurement, were used to illustrate the capabilities of VEM: (a) poultry farming activities and (b) powder transfer operations in a pharmaceutical company. For the poultry farm work, the real-time monitors were calibrated with respect to the respirable and inhalable dust concentrations using cyclone and IOM reference samplers respectively. Different rankings of exposure for typical activities were found on the small farm studied here compared to previous exposure measurements at larger poultry farms: these were mainly attributed to the different scales of operation. Large variations in the ratios of respirable, inhalable and real-time monitor TWA concentrations of poultry farm dust for various activities were found. This has implications for the calibration of light-scattering dust monitors with respect to inhalable dust concentration. In the pharmaceutical application, the effectiveness of a curtain barrier for dust control when dispensing powder in a downflow booth was rapidly demonstrated.

  1. 78 FR 25308 - Proposed Collection; Comment Request; Coal Mine Dust Sampling Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-30

    ...; Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day.... Background Continuous Personal Dust Monitors (CPDMs) determine the concentration of respirable dust in coal mines. CPDMs must be designed and constructed for coal miners to wear and operate without impeding their...

  2. In-depth survey report: control technology for manual transfer of chemical powders at the B. F. Goodrich Company, Marietta, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gressel, M.G.; Heitbrink, W.A.; McGlothlin, J.D.

    1985-12-01

    A field study was conducted in the B.F. Goodrich Industrial Plastics Division facility, Marietta, Ohio to evaluate sources of worker dust exposure at a ventilated booth used for the weigh out and transfer of powdered materials from large drums to small bags. The sources of dust exposure evaluated were: depth of scooping, clothing, worker anthropometry, work practices, biomechanics, and specific items in the job cycle. Dust exposure for workers wearing clean clothing was not significantly different from exposure for workers wearing dirty clothing. Depth of scooping from the drum significantly affected dust exposure. There appeared also to be a relationshipmore » between the size of the worker and dust exposure when scooping from the bottom of the drum. Work practices may also play a part. The authors conclude that, while the results showed abnormally high dust levels, all three workers studied wore respirable dust respirators during the experiment to protect them from these high levels. Air flow patterns at the booth suggest that the ventillation provided may even contributed to dust exposure.« less

  3. Comparing two-zone models of dust exposure.

    PubMed

    Jones, Rachael M; Simmons, Catherine E; Boelter, Fred W

    2011-09-01

    The selection and application of mathematical models to work tasks is challenging. Previously, we developed and evaluated a semi-empirical two-zone model that predicts time-weighted average (TWA) concentrations (Ctwa) of dust emitted during the sanding of drywall joint compound. Here, we fit the emission rate and random air speed variables of a mechanistic two-zone model to testing event data and apply and evaluate the model using data from two field studies. We found that the fitted random air speed values and emission rate were sensitive to (i) the size of the near-field and (ii) the objective function used for fitting, but this did not substantially impact predicted dust Ctwa. The mechanistic model predictions were lower than the semi-empirical model predictions and measured respirable dust Ctwa at Site A but were within an acceptable range. At Site B, a 10.5 m3 room, the mechanistic model did not capture the observed difference between PBZ and area Ctwa. The model predicted uniform mixing and predicted dust Ctwa up to an order of magnitude greater than was measured. We suggest that applications of the mechanistic model be limited to contexts where the near-field volume is very small relative to the far-field volume.

  4. Endotoxin and dust at respirable and nonrespirable particle sizes are not consistent between cage- and floor-housed poultry operations.

    PubMed

    Kirychuk, Shelley P; Reynolds, Stephen J; Koehncke, Niels K; Lawson, Joshua; Willson, Philip; Senthilselvan, Ambikaipakan; Marciniuk, Darcy; Classen, Henry L; Crowe, Trever; Just, Natasha; Schneberger, David; Dosman, James A

    2010-10-01

    Individuals engaged in work in intensive animal houses experience some of the highest rates of occupationally related respiratory symptoms. Organic dust and in particular endotoxin has been most closely associated with respiratory symptoms and lung function changes in workers. It has previously been shown that for intensive poultry operations, type of poultry housing [cage-housed (CH) versus floor-housed (FH)] can influence the levels of environmental contaminants. The goal of the study was to determine the differences in endotoxin and dust levels at different size fractions between CH and FH poultry operations. Fifteen CH and 15 FH poultry operations were sampled for stationary measurements (area) of dust and associated endotoxin. Fractioned samples were collected utilizing Marple cascade impactors. Gravimetric and endotoxin analysis were conducted on each of the filters. When assessed by individual Marple stage, there was significantly greater airborne endotoxin concentration (endotoxin units per cubic meter) in the size fraction >9.8 μm for the FH operations whereas at the size fraction 1.6-3.5 μm, the CH operations had significantly greater airborne endotoxin concentration than the FH operations. Endotoxin concentration in the dust mass (endotoxin units per milligram) was significantly greater in the CH operations as compared to the FH operations for all size fractions >1.6 μm. As such, endotoxin in the respirable fraction accounted for 24% of the total endotoxin in the CH operations whereas it accounted for only 11% in the FH operations. There was significantly more dust in all size fractions in the FH operations as compared to the CH poultry operations. There is more endotoxin in the presence of significantly lower dust levels in the respirable particle size fractions in CH poultry operations as compared to the FH poultry operations. This difference in respirable endotoxin may be important in relation to the differential respiratory response experienced by CH and FH poultry operation workers.

  5. Risks of respiratory disease in the heavy clay industry

    PubMed Central

    Love, R. G.; Waclawski, E. R.; Maclaren, W. M.; Wetherill, G. Z.; Groat, S. K.; Porteous, R. H.; Soutar, C. A.

    1999-01-01

    OBJECTIVES: Little information is available on the quantitative risks of respiratory disease from quartz in airborne dust in the heavy clay industry. Available evidence suggested that these risks might be low, possibly because of the presence in the dust of other minerals, such as illite and kaolinite, which may reduce the harmful effects of quartz. The aims of the present cross sectional study were to determine among workers in the industry (a) their current and cumulative exposures to respirable mixed dust and quartz; (b) the frequencies of chest radiographic abnormalities and respiratory symptoms; (c) the relations between cumulative exposure to respirable dust and quartz, and risks of radiographic abnormality and respiratory symptoms. METHODS: Factories were chosen where the type of process had changed as little as possible during recent decades. 18 were selected in England and Scotland, ranging in size from 35 to 582 employees, representing all the main types of raw material, end product, kilns, and processes in the manufacture of bricks, pipes, and tiles but excluding refractory products. Weights of respirable dust and quartz in more than 1400 personal dust samples, and site histories, were used to derive occupational groups characterised by their levels of exposure to dust and quartz. Full size chest radiographs, respiratory symptoms, smoking, and occupational history questionnaires were administered to current workers at each factory. Exposure-response relations were examined for radiographic abnormalities (dust and quartz) and respiratory symptoms (dust only). RESULTS: Respirable dust and quartz concentrations ranged from means of 0.4 and 0.04 mg.m-3 for non-process workers to 10.0 and 0.62 mg.m-3 for kiln demolition workers respectively. Although 97% of all quartz concentrations were below the maximum exposure limit of 0.4 mg.m-3, 10% were greater than this among the groups of workers exposed to most dust. Cumulative exposure calculations for dust and quartz took account of changes of occupational group, factory, and kiln type at study and non-study sites. Because of the importance of changes of kiln type additional weighting factors were applied to concentrations of dust and quartz during previous employment at factories that used certain types of kiln. 85% (1934 employees) of the identified workforce attended the medical surveys. The frequency of small opacities in the chest radiograph, category > or = 1/0, was 1.4% (median reading) and seven of these 25 men had category > or = 2/1. Chronic bronchitis was reported by 14.2% of the workforce and breathlessness, when walking with someone of their own age, by 4.4%. Risks of having category > or = 0/1 small opacities differed by site and were also influenced by age, smoking, and lifetime cumulative exposure to respirable dust and quartz. Although exposures to dust and to quartz were highly correlated, the evidence suggested that radiological abnormality was associated with quartz rather than dust. A doubling of cumulative quartz exposure increased the risk of having category > or = 0/1 by a factor of 1.33. Both chronic bronchitis and breathlessness were significantly related to dust exposure. CONCLUSIONS: Although most quartz concentrations at the time of this study were currently below regulatory limits in the heavy clay industry, high exposures regularly occurred in specific processes and occasionally among most occupational groups. However, there are small risks of pneumoconiosis and respiratory symptoms in the industry, although frequency of pneumoconiosis is low in comparison to other quartz exposed workers.   PMID:10448318

  6. Physicochemical properties of respirable-size lunar dust

    NASA Astrophysics Data System (ADS)

    McKay, D. S.; Cooper, B. L.; Taylor, L. A.; James, J. T.; Thomas-Keprta, K.; Pieters, C. M.; Wentworth, S. J.; Wallace, W. T.; Lee, T. S.

    2015-02-01

    We separated the respirable dust and other size fractions from Apollo 14 bulk sample 14003,96 in a dry nitrogen environment. While our toxicology team performed in vivo and in vitro experiments with the respirable fraction, we studied the size distribution and shape, chemistry, mineralogy, spectroscopy, iron content and magnetic resonance of various size fractions. These represent the finest-grained lunar samples ever measured for either FMR np-Fe0 index or precise bulk chemistry, and are the first instance we know of in which SEM/TEM samples have been obtained without using liquids. The concentration of single-domain, nanophase metallic iron (np-Fe0) increases as particle size diminishes to 2 μm, confirming previous extrapolations. Size-distribution studies disclosed that the most frequent particle size was in the 0.1-0.2 μm range suggesting a relatively high surface area and therefore higher potential toxicity. Lunar dust particles are insoluble in isopropanol but slightly soluble in distilled water (~0.2 wt%/3 days). The interaction between water and lunar fines, which results in both agglomeration and partial dissolution, is observable on a macro scale over time periods of less than an hour. Most of the respirable grains were smooth amorphous glass. This suggests less toxicity than if the grains were irregular, porous, or jagged, and may account for the fact that lunar dust is less toxic than ground quartz.

  7. Carbohydrate and protein contents of grain dusts in relation to dust morphology.

    PubMed Central

    Dashek, W V; Olenchock, S A; Mayfield, J E; Wirtz, G H; Wolz, D E; Young, C A

    1986-01-01

    Grain dusts contain a variety of materials which are potentially hazardous to the health of workers in the grain industry. Because the characterization of grain dusts is incomplete, we are defining the botanical, chemical, and microbial contents of several grain dusts collected from grain elevators in the Duluth-Superior regions of the U.S. Here, we report certain of the carbohydrate and protein contents of dusts in relation to dust morphology. Examination of the gross morphologies of the dusts revealed that, except for corn, each dust contained either husk or pericarp (seed coat in the case of flax) fragments in addition to respirable particles. When viewed with the light microscope, the fragments appeared as elongated, pointed structures. The possibility that certain of the fragments within corn, settled, and spring wheat were derived from cell walls was suggested by the detection of pentoses following colorimetric assay of neutralized 2 N trifluoroacetic acid hydrolyzates of these dusts. The presence of pentoses together with the occurrence of proteins within water washings of grain dusts suggests that glycoproteins may be present within the dusts. With scanning electron microscopy, each dust was found to consist of a distinct assortment of particles in addition to respirable particles. Small husk fragments and "trichome-like" objects were common to all but corn dust. Images FIGURE 4. FIGURE 5. PMID:3709476

  8. Exposure to silica and silicosis among tin miners in China: exposure-response analyses and risk assessment

    PubMed Central

    Chen, W; Zhuang, Z; Attfield, M; Chen, B; Gao, P.; Harrison, J; Fu, C; Chen, J; Wallace, W

    2001-01-01

    OBJECTIVES—To investigate the risk of silicosis among tin miners and to investigate the relation between silicosis and cumulative exposure to dust (Chinese total dust and respirable crystalline silica dust).
METHODS—A cohort study of 3010 miners exposed to silica dust and employed for at least 1 year during 1960-5 in any of four Chinese tin mines was conducted. Historical total dust data from China were used to create a job exposure matrix for facility, job title, and calendar year. The total dust exposure data from China were converted to estimates of exposure to respirable crystalline silica for comparison with findings from other epidemiological studies of silicosis. Each worker's work history was abstracted from the complete employment records in mine files. Diagnoses of silicosis were based on 1986 Chinese pneumoconiosis Roentgen diagnostic criteria, which classified silicosis as stages I-III—similar to an International Labour Organisation (ILO) classification of 1/1 or greater.
RESULTS—There were 1015 (33.7%) miners identified with silicosis, who had a mean age of 48.3 years, with a mean of 21.3 years after first exposure (equivalent to 11.0 net years in a dusty job). Among those who had silicosis, 684 miners (67.4%) developed silicosis after exposure ended (a mean of 3.7 years after). The risk of silicosis was strongly related to cumulative exposure to silica dust and was well fitted by the Weibull distribution, with the risk of silicosis less than 0.1% when the Chinese measure of cumulative exposure to total dust (CTD) was under 10 mg/m3-years (or 0.36 mg/m3-years of respirable crystalline silica), increasing to 68.7% when CTD exposure was 150 mg/m3-years (or 5.4 mg/m3-years of respirable crystalline silica). Latency period was not correlated to the risk of silicosis or cumulative dose of exposure. This study predicts about a 36% cumulative risk of silicosis for a 45 year lifetime exposure to these tin mine dusts at the CTD exposure standard of 2 mg/m3, and a 55% risk at 45 years exposure to the current United States Occupational Safety and Health Administration and Mine Safety and Health Administration standards of 0.1 mg/m3 100% respirable crystalline silica dust.
CONCLUSIONS—A clear exposure-response relation was detected for silicosis in Chinese tin miners. The study results were similar to most, but not all, findings from other large scale exposure-response studies.


Keywords: silicosis; exposure to silica; dose-response relation PMID:11119632

  9. Changes in lung function after exposure to vanadium compounds in fuel oil ash

    PubMed Central

    Lees, R E M

    1980-01-01

    ABSTRACT Seventeen men were studied during the cleaning of bottom ash from the boiler of an oil-fired electricity generating station. The men were exposed to a time weighted average respirable dust (<10 μ) of 523 μg/m3, containing 15·3% vanadium. Sixteen of the men wore respirators, subsequently found to have peak leakages of up to 9%, while one volunteer had a one-hour exposure wearing only a compressed paper oronasal mask. Symptoms experienced by the men were recorded, urine samples were collected for assessment of vanadium concentration 24 hours after the first exposure, and spirometry was performed daily for four days and on the eight day. Pronounced reductions in forced vital capacity (mean 0·5 l), forced expiratory volume (mean 0·5 l), and forced mid-expiratory flow (mean 1·16 l/s) had occurred within 24 hours of first exposure to the dust, and had not returned to pre-exposure levels by the eight day. Four weeks after exposure no residual deficits were present. A urinary vanadium concentration of 280 μg/l was found in the volunteer, but none of the others had concentrations above the test-threshold of 40 μg/l. Symptoms and signs of airway irritation were noted. The timing, duration, and quality of changes in lung function, however, indicated that the response could not be attributed solely to a reflex bronchial reaction to irritation by an inert dust. PMID:7426476

  10. Crystalline silica exposure and lung cancer mortality in diatomaceous earth industry workers: a quantitative risk assessment.

    PubMed

    Rice, F L; Park, R; Stayner, L; Smith, R; Gilbert, S; Checkoway, H

    2001-01-01

    To use various exposure-response models to estimate the risk of mortality from lung cancer due to occupational exposure to respirable crystalline silica dust. Data from a cohort mortality study of 2342 white male California diatomaceous earth mining and processing workers exposed to crystalline silica dust (mainly cristobalite) were reanalyzed with Poisson regression and Cox's proportional hazards models. Internal and external adjustments were used to control for potential confounding from the effects of time since first observation, calendar time, age, and Hispanic ethnicity. Cubic smoothing spline models were used to assess the fit of the models. Exposures were lagged by 10 years. Evaluations of the fit of the models were performed by comparing their deviances. Lifetime risks of lung cancer were estimated up to age 85 with an actuarial approach that accounted for competing causes of death. Exposure to respirable crystalline silica dust was a significant predictor (p<0.05) in nearly all of the models evaluated and the linear relative rate model with a 10 year exposure lag seemed to give the best fit in the Poisson regression analysis. For those who died of lung cancer the linear relative rate model predicted rate ratios for mortality from lung cancer of about 1.6 for the mean cumulative exposure to respirable silica compared with no exposure. The excess lifetime risk (to age 85) of mortality from lung cancer for white men exposed for 45 years and with a 10 year lag period at the current Occupational Safety and Health Administration (OSHA) standard of about 0.05 mg/m(3) for respirable cristobalite dust is 19/1000 (95% confidence interval (95% CI) 5/1000 to 46/1000). There was a significant risk of mortality from lung cancer that increased with cumulative exposure to respirable crystalline silica dust. The predicted number of deaths from lung cancer suggests that current occupational health standards may not be adequately protecting workers from the risk of lung cancer.

  11. Biological indicators of exposure to total and respirable aluminium dust fractions in a primary aluminium smelter.

    PubMed Central

    Röllin, H B; Theodorou, P; Cantrell, A C

    1996-01-01

    OBJECTIVES: The study attempts to define biological indicators of aluminium uptake and excretion in workers exposed to airborne aluminium compounds in a primary aluminium smelter. Also, this study defines the total and respirable aluminium dust fractions in two different potrooms, and correlates their concentrations with biological indicators in this group of workers. METHODS: Air was sampled at defined work sites. Non-destructive and conventional techniques were used to find total and respirable aluminium content of the dust. Blood and urine was collected from 84 volunteers employed at various work stations throughout the smelter and from two different cohorts of controls matched for sex, age, and socioeconomic status. Aluminium in serum samples and urine specimens was measured by flameless atomic absorption with a PE 4100 ZL spectrometer. RESULTS: The correlation of aluminium concentrations in serum and urine samples with the degree of exposure was assessed for three arbitrary exposure categories; low (0.036 mg Al/m3), medium (0.35 mg Al/m3) and high (1.47 mg Al/m3) as found in different areas of the smelter. At medium and high exposure, the ratio of respirable to total aluminium in the dust samples varied significantly. At high exposure, serum aluminium, although significantly raised, was still within the normal range of an unexposed population. The workers with low exposure excreted aluminium in urine at levels significantly higher than the controls, but still within the normal range of the population. However, potroom workers with medium and high exposure had significantly higher urinary aluminium than the normal range. CONCLUSIONS: It is concluded that only urinary aluminium constitutes a practical index of occupational exposure at or above 0.35 mg Al/m3, and that the respirable fraction of the dust may play a major role in the biological response to exposure to aluminium in a smelter environment. PMID:8758038

  12. Development of an Advanced Respirator Fit Test Headform (Postprint)

    DTIC Science & Technology

    2012-11-01

    needed to measure the fit of N95 filtering facepiece respirators (FFRs) for protection studies against viable airborne particles. The objective of...N95 filtering facepiece respirators (FFRs) for pro- tection studies against viable airborne particles. A Static (i.e., non-moving, non-speaking...The N95 class of filtering facepiece respirators (FFRs) is commonly used to re- duce exposure to airborne particles, including oil-free aerosols (dusts

  13. Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

    PubMed

    Halterman, Andrew; Sousan, Sinan; Peters, Thomas M

    2017-12-15

    In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  14. Exposure to grain dust in Great Britain.

    PubMed

    Spankie, Sally; Cherrie, John W

    2012-01-01

    Airborne grain dust is a complex mixture of fragments of organic material from grain, plus mineral matter from soil, and possible insect, fungal, or bacterial contamination or their toxic products, such as endotoxin. In the 1990s, grain workers in Britain were frequently exposed to inhalable dust >10 mg.m(-3) (8 h), with particularly high exposures being found at terminals where grain was imported or exported and in drying operations (personal exposure typically approximately 20 mg.m(-3)). Since then, the industry has made substantial progress in improving the control of airborne dust through better-designed processes, increased automation, and an improved focus on product quality. We have used information from the published scientific literature and a small survey of industry representatives to estimate current exposure levels. These data suggest that current long-term exposure to inhalable dust for most workers is on average less than approximately 3 mg.m(-3), with perhaps 15-20% of individual personal exposures being >10 mg.m(-3). There are no published data from Britain on short-term exposure during cleaning and other tasks. We have estimated average levels for a range of tasks and judge that the highest levels, for example during some cleaning activities and certain process tasks such as loading and packing, are probably approximately10 mg.m(-3). Endotoxin levels were judged likely to be <10⁴ EU m(-3) throughout the industry provided inhalable dust levels are <10 mg.m(-3). There are no published exposure data on mycotoxin, respirable crystalline silica, and mite contamination but these are not considered to present widespread problems in the British industry. Further research should be carried out to confirm these findings.

  15. Lead Exposure Assessment among Pregnant Women, Newborns, and Children: Case Study from Karachi, Pakistan.

    PubMed

    Fatmi, Zafar; Sahito, Ambreen; Ikegami, Akihiko; Mizuno, Atsuko; Cui, Xiaoyi; Mise, Nathan; Takagi, Mai; Kobayashi, Yayoi; Kayama, Fujio

    2017-04-13

    Lead (Pb) in petrol has been banned in developed countries. Despite the control of Pb in petrol since 2001, high levels were reported in the blood of pregnant women and children in Pakistan. However, the identification of sources of Pb has been elusive due to its pervasiveness. In this study, we assessed the lead intake of pregnant women and one- to three-year-old children from food, water, house dust, respirable dust, and soil. In addition, we completed the fingerprinting of the Pb isotopic ratios (LIR) of petrol and secondary sources (food, house-dust, respirable dust, soil, surma (eye cosmetics)) of exposure within the blood of pregnant women, newborns, and children. Eight families, with high (~50 μg/dL), medium (~20 μg/dL), and low blood levels (~10 μg/dL), were selected from 60 families. The main sources of exposure to lead for children were food and house-dust, and those for pregnant women were soil, respirable dust, and food. LIR was determined by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) with a two sigma uncertainty of ±0.03%. The LIR of mothers and newborns was similar. In contrast, surma , and to a larger extent petrol, exhibited a negligible contribution to both the child's and mother's blood Pb. Household wet-mopping could be effective in reducing Pb exposure. This intake assessment could be replicated for other developing countries to identify sources of lead and the burden of lead exposure in the population.

  16. Evaluation of Respirable Crystalline Silica in High School Ceramics Classrooms

    PubMed Central

    Fechser, Matthew; Alaves, Victor; Larson, Rodney; Sleeth, Darrah

    2014-01-01

    Air concentrations of respirable crystalline silica were measured in eleven (11) high school ceramics classrooms located in Salt Lake County, UT, USA. Respirable dust was collected on PVC filters using precision flow pumps and cyclone samplers (n = 44). Filters were subsequently analyzed for respirable dust and percent crystalline silica content. The geometric mean of the silica concentrations was 0.009 mg/m3 near the teacher’s work station and 0.008 mg/m3 near the kilns. The number of students in the classroom was correlated to the silica concentration in the ceramics classroom, but no correlation was found between the silica concentrations and either the size of the classroom or the age of the building. Results from this study indicate that ceramics teachers may be at an increased risk of exposure to crystalline silica based on the ACGIH TLV of 0.025 mg/m3, with an exceedance of 21%. PMID:24464235

  17. Evaluation of respirable crystalline silica in high school ceramics classrooms.

    PubMed

    Fechser, Matthew; Alaves, Victor; Larson, Rodney; Sleeth, Darrah

    2014-01-23

    Air concentrations of respirable crystalline silica were measured in eleven (11) high school ceramics classrooms located in Salt Lake County, UT, USA. Respirable dust was collected on PVC filters using precision flow pumps and cyclone samplers (n = 44). Filters were subsequently analyzed for respirable dust and percent crystalline silica content. The geometric mean of the silica concentrations was 0.009 mg/m3 near the teacher's work station and 0.008 mg/m3 near the kilns. The number of students in the classroom was correlated to the silica concentration in the ceramics classroom, but no correlation was found between the silica concentrations and either the size of the classroom or the age of the building. Results from this study indicate that ceramics teachers may be at an increased risk of exposure to crystalline silica based on the ACGIH TLV of 0.025 mg/m3, with an excess of 21%.

  18. Determinants of dust exposure in tunnel construction work.

    PubMed

    Bakke, Berit; Stewart, Patricia; Eduard, Wijnand

    2002-11-01

    In tunnel construction work, dust is generated from rock drilling, rock bolting, grinding, scaling, and transport operations. Other important dust-generating activities are blasting rock and spraying wet concrete on tunnel walls for strength and finishing work. The aim of this study was to identify determinants of dust exposure in tunnel construction work and to propose control measures. Personal exposures to total dust, respirable dust, and alpha-quartz were measured among 209 construction workers who were divided into 8 job groups performing similar tasks: drill and blast workers, shaft drilling workers, tunnel boring machine workers, shotcreting operators, support workers, concrete workers, outdoor concrete workers, and electricians. Information on determinants was obtained from interviewing the workers, observation by the industrial hygienist responsible for the sampling, and the job site superintendent. Multivariate regression models were used to identify determinants associated with the dust exposures within the job groups. The geometric mean exposure to total dust, respirable dust, and alpha-quartz for all tunnel workers was 3.5 mg/m(3) (GSD = 2.6), 1.2 mg/m(3) (GSD = 2.4), and 0.035 mg/m(3) (GSD = 5.0), respectively. A total of 15 percent of the total dust measurements, 5 percent of the respirable dust, and 21 percent of the alpha-quartz exceeded the Norwegian OELs of 10 mg/m(3), 5 mg/m(3), and 0.1 mg/m(3), respectively. Job groups with highest geometric mean total dust exposure were shotcreting operators (6.8 mg/m(3)), tunnel boring machine workers (6.2 mg/m(3)), and shaft drilling workers (6.1 mg/m(3)). The lowest exposed groups to total dust were outdoor concrete workers (1.0 mg/m(3)), electricians (1.4 mg/m(3)), and support workers (1.9 mg/m(3)). Important determinants of exposure were job group, job site, certain tasks (e.g., drilling and scaling), the presence of a cab, and breakthrough of the tunnel. The use of ventilated, closed cabs appeared to be the single most important control measure for lowering exposures.

  19. A comparison between standard methods and structural nested modelling when bias from a healthy worker survivor effect is suspected: an iron-ore mining cohort study.

    PubMed

    Björ, Ove; Damber, Lena; Jonsson, Håkan; Nilsson, Tohr

    2015-07-01

    Iron-ore miners are exposed to extremely dusty and physically arduous work environments. The demanding activities of mining select healthier workers with longer work histories (ie, the Healthy Worker Survivor Effect (HWSE)), and could have a reversing effect on the exposure-response association. The objective of this study was to evaluate an iron-ore mining cohort to determine whether the effect of respirable dust was confounded by the presence of an HWSE. When an HWSE exists, standard modelling methods, such as Cox regression analysis, produce biased results. We compared results from g-estimation of accelerated failure-time modelling adjusted for HWSE with corresponding unadjusted Cox regression modelling results. For all-cause mortality when adjusting for the HWSE, cumulative exposure from respirable dust was associated with a 6% decrease of life expectancy if exposed ≥15 years, compared with never being exposed. Respirable dust continued to be associated with mortality after censoring outcomes known to be associated with dust when adjusting for the HWSE. In contrast, results based on Cox regression analysis did not support that an association was present. The adjustment for the HWSE made a difference when estimating the risk of mortality from respirable dust. The results of this study, therefore, support the recommendation that standard methods of analysis should be complemented with structural modelling analysis techniques, such as g-estimation of accelerated failure-time modelling, to adjust for the HWSE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Estimation of respirable dust exposure among coal miners in South Africa.

    PubMed

    Naidoo, Rajen; Seixas, Noah; Robins, Thomas

    2006-06-01

    The use of retrospective occupational hygiene data for epidemiologic studies is useful in determining exposure-outcome relationships, but the potential for exposure misclassification is high. Although dust sampling in the South African coal industry has been a legal requirement for several decades, these historical data are not readily adequate for estimating past exposures. This study describes the respirable coal mine dust levels in three South African coal mines over time. Each of the participating mining operations had well-documented dust sampling information that was used to describe historical trends in dust exposure. Investigator-collected personal dust samples were taken using standardized techniques from the face, backbye (underground jobs not at the coal face), and surface from 50 miners at each mine, repeated over three sampling cycles. Job histories and exposure information was obtained from a sample of 684 current miners and 188 ex-miners. Linear models were developed to estimate the exposure levels associated with work in each mine, exposure zone, and over time using a combination of operator-collected historical data and investigator-collected samples. The estimated levels were then combined with work history information to calculate cumulative exposure metrics for the miner cohort. The mean historical and investigator-collected respirable dust levels were within international norms and South African standards. Silica content of the dust samples was also below the 5% regulatory action level. Mean respirable dust concentrations at the face, based on investigator-collected samples, were 0.9 mg/m(3), 1.3 mg/m(3), and 1.9 mg/m(3) at Mines 1, 2, and 3, respectively. The operator-collected samples showed considerable variability across exposure zones, mines, and time, with the annual means at the face ranging from 0.4 mg/m(3) to 2.9 mg/m(3). Statistically significant findings were found between operator- and investigator-collected dust samples. Model-based arithmetic mean dust estimates at the face were 1.2 mg/m(3), 2.0 mg/m(3), and 0.9 mg/m(3) for Mines 1, 2, and 3, respectively. Using these levels, the mean cumulative exposure for the cohort was 56.8 mg-years/m(3). Current miners had a mean cumulative exposure of 66.5 mg-years/m(3), compared with ex-miners of 26.8 mg-years/m(3). Improvements in dust management or the use of different sampling equipment could account for the significant differences seen between operator- and investigator-collected data. Regression modeling for estimating mean dust levels over time using combined historical and investigator-collected data seems a reasonable method and useful in constructing models to describe cumulative exposures in a cohort of current and ex-miners.

  1. Respiratory disease mortality among US coal miners; results after 37 years of follow-up

    PubMed Central

    Graber, Judith M; Stayner, Leslie T; Cohen, Robert A; Conroy, Lorraine M; Attfield, Michael D

    2015-01-01

    Objectives To evaluate respiratory related mortality among underground coal miners after 37 years of follow-up. Methods Underlying cause of death for 9033 underground coal miners from 31 US mines enrolled between 1969 and 1971 was evaluated with life table analysis. Cox proportional hazards models were fitted to evaluate the exposure-response relationships between cumulative exposure to coal mine dust and respirable silica and mortality from pneumoconiosis, chronic obstructive pulmonary disease (COPD) and lung cancer. Results Excess mortality was observed for pneumoconiosis (SMR=79.70, 95% CI 72.1 to 87.67), COPD (SMR=1.11, 95% CI 0.99 to 1.24) and lung cancer (SMR=1.08; 95% CI 1.00 to 1.18). Coal mine dust exposure increased risk for mortality from pneumoconiosis and COPD. Mortality from COPD was significantly elevated among ever smokers and former smokers (HR=1.84, 95% CI 1.05 to 3.22; HRK=1.52, 95% CI 0.98 to 2.34, respectively) but not current smokers (HR=0.99, 95% CI 0.76 to 1.28). Respirable silica was positively associated with mortality from pneumoconiosis (HR=1.33, 95% CI 0.94 to 1.33) and COPD (HR=1.04, 95% CI 0.96 to 1.52) in models controlling for coal mine dust. We saw a significant relationship between coal mine dust exposure and lung cancer mortality (HR=1.70; 95% CI 1.02 to 2.83) but not with respirable silica (HR=1.05; 95% CI 0.90 to 1.23). In the most recent follow-up period (2000–2007) both exposures were positively associated with lung cancer mortality, coal mine dust significantly so. Conclusions Our findings support previous studies showing that exposure to coal mine dust and respirable silica leads to increased mortality from malignant and non-malignant respiratory diseases even in the absence of smoking. PMID:24186945

  2. Dust exposure and pneumoconiosis in a South African pottery. 1. Study objectives and dust exposure.

    PubMed Central

    Rees, D; Cronje, R; du Toit, R S

    1992-01-01

    Dust exposure and pneumoconiosis were investigated in a South African pottery that manufactured wall tiles and bathroom fittings. This paper describes the objectives of the investigation and presents dust measurement data. x Ray diffraction showed that the clays used by the pottery had a high quartz content (range 58%-23%, mean 38%). Exposure to respirable dust was measured for 43 workers and was highest (6.6 mg/m3) in a bathroom fitting fettler. Quartz concentrations in excess of 0.1 mg/m3 were found in all sections of the manufacturing process from slip production to biscuit firing and sorting. The proportion of quartz in the respirable dust of these sections was 24% to 33%. This is higher than is usually reported in English potteries. Four hundred and six (80%) of the 509 workers employed at the pottery were potentially at risk of occupational lung disease. The finding of large numbers of pottery workers exposed to unacceptable dust concentrations is not surprising as poor dust control was found in all six wall tile and sanitary ware factories surveyed by the National Centre for Occupational Health between 1973 and 1989. Dust related occupational disease can be expected in potters for many years to come. PMID:1637705

  3. Dust exposure and pneumoconiosis in a South African pottery. 1. Study objectives and dust exposure.

    PubMed

    Rees, D; Cronje, R; du Toit, R S

    1992-07-01

    Dust exposure and pneumoconiosis were investigated in a South African pottery that manufactured wall tiles and bathroom fittings. This paper describes the objectives of the investigation and presents dust measurement data. x Ray diffraction showed that the clays used by the pottery had a high quartz content (range 58%-23%, mean 38%). Exposure to respirable dust was measured for 43 workers and was highest (6.6 mg/m3) in a bathroom fitting fettler. Quartz concentrations in excess of 0.1 mg/m3 were found in all sections of the manufacturing process from slip production to biscuit firing and sorting. The proportion of quartz in the respirable dust of these sections was 24% to 33%. This is higher than is usually reported in English potteries. Four hundred and six (80%) of the 509 workers employed at the pottery were potentially at risk of occupational lung disease. The finding of large numbers of pottery workers exposed to unacceptable dust concentrations is not surprising as poor dust control was found in all six wall tile and sanitary ware factories surveyed by the National Centre for Occupational Health between 1973 and 1989. Dust related occupational disease can be expected in potters for many years to come.

  4. Cross-shift peak expiratory flow changes are unassociated with respirable coal dust exposure among South African coal miners.

    PubMed

    Naidoo, Rajen N; Robins, Thomas G; Becklake, Margaret; Seixas, Noah; Thompson, Mary Lou

    2007-12-01

    The objectives of this study were to determine whether cross-shift changes in peak expiratory flow rate (PEFR) were related to respirable dust exposure in South African coalminers. Fifty workers were randomly selected from a cohort of 684 miners from 3 bituminous coalmines in Mpumalanga, South Africa. Peak expiratory efforts were measured prior to the commencement of the shift, and at the end of the shift on at least two occasions separated by at least 2 weeks, with full shift personal dust sampling being conducted on each occasion for each participant. Interviews were conducted, work histories were obtained and cumulative exposure estimates were constructed. Regression models examined the associations of cross-shift changes in PEFR with current and cumulative exposure, controlling for shift, smoking and past history of tuberculosis. There were marginal differences in cross-shift PEFR (ranging from 0.1 to 2 L/min). Linear regression analyses showed no association between cross-shift change in PEFR and current or cumulative exposure. The specific shift worked by participants in the study showed no effect. Our study showed no association between current respirable dust exposure and cross-shift changes in PEFR. There was a non-significant protective effect of cumulative dust exposure on the outcome, suggesting the presence of a "healthy worker survivor effect" in this data.

  5. Contrasting respirable quartz and kaolin retention of lecithin surfactant and expression of membranolytic activity following phospholipase A2 digestion.

    PubMed

    Wallace, W E; Keane, M J; Mike, P S; Hill, C A; Vallyathan, V; Regad, E D

    1992-11-01

    Respirable-sized quartz, a well-established fibrogenic mineral dust, is compared with kaolin in erythrocyte hemolysis assays after treatment with saline dispersion of dipalmitoyl phosphatidylcholine, a primary phospholipid component of pulmonary surfactant. Both dusts are rendered inactive after treatment, but the membranolytic activity is partly to fully restored after treatment with phospholipase A2, an enzyme normally associated with cellular plasma membranes and lysosomes. Phospholipid-coated dusts were incubated for periods of 2-72 h at a series of applied enzyme concentrations, and the adsorbed lipid species and hemolytic activity were quantitated at each time for both dusts. Surfactant was lost more readily from quartz than from kaolin, with consequent more rapid restoration of mineral surface hemolytic activity for quartz. Interactions of surfactant and mineral surface functional groups responsible for the mineral-specific rate differences, and implications for determining the mineral surface bioavailability of silica and silicate dusts, are discussed.

  6. Examination of a newly developed mobile dry scrubber (DS) for coal mine dust control applications

    PubMed Central

    Organiscak, J.; Noll, J.; Yantek, D.; Kendall, B.

    2017-01-01

    The Office of Mine Safety and Health Research of the U.S. National Institute for Occupational Safety and Health (NIOSH OMSHR) conducted laboratory testing of a self-tramming, remotely controlled mobile Dry Scrubber (DS) that J.H. Fletcher and Co. developed under a contract with NIOSH OMSHR to reduce the exposure of miners to airborne dust. The scrubber was found to average greater than 95 percent dust removal efficiency with disposable filters, and 88 and 90 percent, respectively, with optional washable filters in their prewash and post-wash test conditions. Although the washable filters can be reused, washing them generated personal and downstream respirable dust concentrations of 1.2 and 8.3 mg/m3, respectively, for a 10-min washing period. The scrubber’s velocity-pressure-regulated variable-frequency-drive fan maintained relatively consistent airflow near the targeted 1.42 and 4.25 m3/s (3,000 and 9,000 ft3/min) airflow rates during most of the laboratory dust testing until reaching its maximum 60-Hz fan motor frequency or horsepower rating at 2,610 Pa (10.5 in. w.g.) of filter differential pressure and 3.97 m3/s (8,420 ft3/min) of scrubber airflow quantity. Laboratory sound level measurements of the scrubber showed that the outlet side of the scrubber was noisier, and the loaded filters increased sound levels compared with clean filters at the same airflow quantities. With loaded filters, the scrubber reached a 90 dB(A) sound level at 2.83 m3/s (6,000 ft3/min) of scrubber airflow, indicating that miners should not be overexposed in relation to MSHA’s permissible exposure level — under Title 30 Code of Federal Regulations Part 62.101— of 90 dB(A) at or below this airflow quantity. The scrubber’s washable filters were not used during field-testing because of their lower respirable dust removal efficiency and the airborne dust generated by filter washing. Field-testing the scrubber with disposable filters at two underground coal mine sections showed that it could clean a portion of the section return air and provide dust reduction of about 50 percent at the face area downstream of the continuous-miner operation. PMID:28596699

  7. 78 FR 45566 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Coal Mine...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-29

    ... for OMB Review; Comment Request; Coal Mine Dust Sampling Devices ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Coal Mine Dust Sampling Devices,'' to the Office of Management...) determine the concentration of respirable dust in coal mines. CPDMs must be designed and constructed for...

  8. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2013-10-01 2013-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  9. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2010-10-01 2010-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  10. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2014-10-01 2014-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  11. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2012-10-01 2012-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  12. 42 CFR 84.1141 - Isoamyl acetate tightness test; dust, fume, and mist respirators designed for respiratory...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist... 42 Public Health 1 2011-10-01 2011-10-01 false Isoamyl acetate tightness test; dust, fume, and...

  13. Biomass fuel use and indoor air pollution in homes in Malawi

    PubMed Central

    Fullerton, D G; Semple, S; Kalambo, F; Suseno, A; Malamba, R; Henderson, G; Ayres, J G; Gordon, S B

    2009-01-01

    Background: Air pollution from biomass fuels in Africa is a significant cause of mortality and morbidity both in adults and children. The work describes the nature and quantity of smoke exposure from biomass fuel in Malawian homes. Methods: Markers of indoor air quality were measured in 62 homes (31 rural and 31 urban) over a typical 24 h period. Four different devices were used (one gravimetric device, two photometric devices and a carbon monoxide (HOBO) monitor. Gravimetric samples were analysed for transition metal content. Data on cooking and lighting fuel type together with information on indicators of socioeconomic status were collected by questionnaire. Results: Respirable dust levels in both the urban and rural environment were high with the mean (SD) 24 h average levels being 226 μg/m3 (206 μg/m3). Data from real-time instruments indicated respirable dust concentrations were >250 μg/m3 for >1 h per day in 52% of rural homes and 17% of urban homes. Average carbon monoxide levels were significantly higher in urban compared with rural homes (6.14 ppm vs 1.87 ppm; p<0.001). The transition metal content of the smoke was low, with no significant difference found between urban and rural homes. Conclusions: Indoor air pollution levels in Malawian homes are high. Further investigation is justified because the levels that we have demonstrated are hazardous and are likely to be damaging to health. Interventions should be sought to reduce exposure to concentrations less harmful to health. PMID:19671533

  14. Differential respirable dust related lung function effects between current and former South African coal miners.

    PubMed

    Naidoo, Rajen N; Robins, Thomas G; Seixas, Noah; Lalloo, Umesh G; Becklake, Margaret

    2005-05-01

    Dust-related dose-response decrements in lung function among coal miners have been reported in several studies, with varying magnitudes across populations. Few studies have compared differences between current and former coal miners. No studies on dose response relationships with lung function have been conducted in South African coal mines, one of the top three producers of coal internationally. The objectives of this study were (1) to describe the relationship between respirable dust exposure and lung function among current and former South African coal miners and to determine whether differential dust related effects were present between these employment categories; (2) to examine dust related dose response relationships, controlling for potential confounding by smoking and a history of tuberculosis (TB). Six hundred and eighty-four current and 188 ex-miners from three bituminous coal mines in Mpumalanga Province were studied. Interviews assessing work histories, smoking profiles and other risk factors were conducted. Work histories were also obtained from company records. Standardised spirometry was performed by trained technicians. Cumulative respirable dust exposure (CDE) estimates were constructed from company-collected sampling and measurements conducted by the researchers. Regression models examined the associations of CDE with per cent predicted FEV(1) and FVC, controlling for smoking, past history of TB and employment status. A statistically significant decline in FEV(1) of 1.1 and 2.2 ml/mg-year/m(3) was found in representative 40-year-old, 1.7-m tall current and former miners, respectively. Significant differences were found between the highest and medium exposure categories. Ex-miners had a lower mean per cent predicted lung function than current miners for each cumulative exposure category, suggesting a "healthy worker" effect. Past history of TB contributed to 21 and 14% declines in per cent predicted FEV(1) and FVC, respectively. Thus, in this cohort, a dose-related decline in lung function was associated with respirable dust exposure, with a magnitude of effect similar to that seen in other studies and important differences between current and former employees. A "healthy worker" effect may have attenuated the magnitude of this relationship. TB was a significant contributor to lung function loss.

  15. The Fox Guarding the Chicken Coop: Monitoring Exposure to Respirable Coal Mine Dust, 1969–2000

    PubMed Central

    Weeks, James L.

    2003-01-01

    Following passage of the Coal Mine Health and Safety Act of 1969, underground coal mine operators were required to take air samples in order to monitor compliance with the exposure limit for respirable dust, a task essential for the prevention of pneumoconiosis among coal workers. Miners objected, claiming that having the mine operators perform this task was like “having the fox guard the chicken coop.” This article is a historical narrative of mining industry corruption and of efforts to reform the program of monitoring exposure to coal mine dust. Several important themes common to the practice of occupational health are illustrated; most prominently, that employers should not be expected to regulate themselves. PMID:12893602

  16. An Evaluation of Sharp Cut Cyclones for Sampling Diesel Particulate Matter Aerosol in the Presence of Respirable Dust

    PubMed Central

    Cauda, Emanuele; Sheehan, Maura; Gussman, Robert; Kenny, Lee; Volkwein, Jon

    2015-01-01

    Two prototype cyclones were the subjects of a comparative research campaign with a diesel particulate matter sampler (DPMS) that consists of a respirable cyclone combined with a downstream impactor. The DPMS is currently used in mining environments to separate dust from the diesel particulate matter and to avoid interferences in the analysis of integrated samples and direct-reading monitoring in occupational environments. The sampling characteristics of all three devices were compared using ammonium fluorescein, diesel, and coal dust aerosols. With solid spherical test aerosols at low particle loadings, the aerodynamic size-selection characteristics of all three devices were found to be similar, with 50% penetration efficiencies (d50) close to the design value of 0.8 µm, as required by the US Mine Safety and Health Administration for monitoring occupational exposure to diesel particulate matter in US mining operations. The prototype cyclones were shown to have ‘sharp cut’ size-selection characteristics that equaled or exceeded the sharpness of the DPMS. The penetration of diesel aerosols was optimal for all three samplers, while the results of the tests with coal dust induced the exclusion of one of the prototypes from subsequent testing. The sampling characteristics of the remaining prototype sharp cut cyclone (SCC) and the DPMS were tested with different loading of coal dust. While the characteristics of the SCC remained constant, the deposited respirable coal dust particles altered the size-selection performance of the currently used sampler. This study demonstrates that the SCC performed better overall than the DPMS. PMID:25060240

  17. Lead Exposure Assessment among Pregnant Women, Newborns, and Children: Case Study from Karachi, Pakistan

    PubMed Central

    Fatmi, Zafar; Sahito, Ambreen; Ikegami, Akihiko; Mizuno, Atsuko; Cui, Xiaoyi; Mise, Nathan; Takagi, Mai; Kobayashi, Yayoi; Kayama, Fujio

    2017-01-01

    Lead (Pb) in petrol has been banned in developed countries. Despite the control of Pb in petrol since 2001, high levels were reported in the blood of pregnant women and children in Pakistan. However, the identification of sources of Pb has been elusive due to its pervasiveness. In this study, we assessed the lead intake of pregnant women and one- to three-year-old children from food, water, house dust, respirable dust, and soil. In addition, we completed the fingerprinting of the Pb isotopic ratios (LIR) of petrol and secondary sources (food, house-dust, respirable dust, soil, surma (eye cosmetics)) of exposure within the blood of pregnant women, newborns, and children. Eight families, with high (~50 μg/dL), medium (~20 μg/dL), and low blood levels (~10 μg/dL), were selected from 60 families. The main sources of exposure to lead for children were food and house-dust, and those for pregnant women were soil, respirable dust, and food. LIR was determined by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) with a two sigma uncertainty of ±0.03%. The LIR of mothers and newborns was similar. In contrast, surma, and to a larger extent petrol, exhibited a negligible contribution to both the child’s and mother’s blood Pb. Household wet-mopping could be effective in reducing Pb exposure. This intake assessment could be replicated for other developing countries to identify sources of lead and the burden of lead exposure in the population. PMID:28406467

  18. Effectiveness of dust control methods for crystalline silica and respirable suspended particulate matter exposure during manual concrete surface grinding.

    PubMed

    Akbar-Khanzadeh, Farhang; Milz, Sheryl A; Wagner, Cynthia D; Bisesi, Michael S; Ames, April L; Khuder, Sadik; Susi, Pam; Akbar-Khanzadeh, Mahboubeh

    2010-12-01

    Concrete grinding exposes workers to unacceptable levels of crystalline silica dust, known to cause diseases such as silicosis and possibly lung cancer. This study examined the influence of major factors of exposure and effectiveness of existing dust control methods by simulating field concrete grinding in an enclosed workplace laboratory. Air was monitored during 201 concrete grinding sessions while using a variety of grinders, accessories, and existing dust control methods, including general ventilation (GV), local exhaust ventilation (LEV), and wet grinding. Task-specific geometric mean (GM) of respirable crystalline silica dust concentrations (mg/m³ for LEV:HEPA-, LEV:Shop-vac-, wet-, and uncontrolled-grinding, while GV was off/on, were 0.17/0.09, 0.57/0.13, 1.11/0.44, and 23.1/6.80, respectively. Silica dust concentrations (mg/m³ using 100-125 mm (4-5 inch) and 180 mm (7 inch) grinding cups were 0.53/0.22 and 2.43/0.56, respectively. GM concentrations of silica dust were significantly lower for (1) GV on (66.0%) vs. off, and (2) LEV:HEPA- (99.0%), LEV:Shop-vac- (98.1%) or wet- (94.4%) vs. uncontrolled-grinding. Task-specific GM of respirable suspended particulate matter (RSP) concentrations (mg/m³ for LEV:HEPA-, LEV:Shop-vac-, wet-, and uncontrolled grinding, while GV was off/on, were 1.58/0.63, 7.20/1.15, 9.52/4.13, and 152/47.8, respectively. GM concentrations of RSP using 100-125 mm and 180 mm grinding cups were 4.78/1.62 and 22.2/5.06, respectively. GM concentrations of RSP were significantly lower for (1) GV on (70.2%) vs. off, and (2) LEV:HEPA- (98.9%), LEV:Shop-vac- (96.9%) or wet- (92.6%) vs. uncontrolled grinding. Silica dust and RSP were not significantly affected by (1) orientation of grinding surfaces (vertical vs. inclined); (2) water flow rates for wet grinding; (3) length of task-specific sampling time; or, (4) among cup sizes of 100, 115 or 125 mm. No combination of factors or control methods reduced an 8-hr exposure level to below the recommended criterion of 0.025 mg/m³ for crystalline silica, requiring further refinement in engineering controls, administrative controls, or the use of respirators.

  19. Crystalline silica exposure and lung cancer mortality in diatomaceous earth industry workers: a quantitative risk assessment

    PubMed Central

    Rice, F; Park, R; Stayner, L; Smith, R; Gilbert, S; Checkoway, H

    2001-01-01

    OBJECTIVE—To use various exposure-response models to estimate the risk of mortality from lung cancer due to occupational exposure to respirable crystalline silica dust.
METHODS—Data from a cohort mortality study of 2342 white male California diatomaceous earth mining and processing workers exposed to crystalline silica dust (mainly cristobalite) were reanalyzed with Poisson regression and Cox's proportional hazards models. Internal and external adjustments were used to control for potential confounding from the effects of time since first observation, calendar time, age, and Hispanic ethnicity. Cubic smoothing spline models were used to assess the fit of the models. Exposures were lagged by 10 years. Evaluations of the fit of the models were performed by comparing their deviances. Lifetime risks of lung cancer were estimated up to age 85 with an actuarial approach that accounted for competing causes of death.
RESULTS—Exposure to respirable crystalline silica dust was a significant predictor (p<0.05) in nearly all of the models evaluated and the linear relative rate model with a 10 year exposure lag seemed to give the best fit in the Poisson regression analysis. For those who died of lung cancer the linear relative rate model predicted rate ratios for mortality from lung cancer of about 1.6 for the mean cumulative exposure to respirable silica compared with no exposure. The excess lifetime risk (to age 85) of mortality from lung cancer for white men exposed for 45 years and with a 10 year lag period at the current Occupational Safety and Health Administration (OSHA) standard of about 0.05 mg/m3 for respirable cristobalite dust is 19/1000 (95% confidence interval (95% CI) 5/1000 to 46/1000).
CONCLUSIONS—There was a significant risk of mortality from lung cancer that increased with cumulative exposure to respirable crystalline silica dust. The predicted number of deaths from lung cancer suggests that current occupational health standards may not be adequately protecting workers from the risk of lung cancer.


Keywords: crystalline silica; cristobalite; lung cancer PMID:11119633

  20. 42 CFR 84.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., or other organization that designs, manufactures, assembles, or controls the assembly of a respirator... source of production and at each step of the manufacturing process, so that departures from... respirator component designed to provide a gas-tight or dust-tight fit with the face and may include...

  1. 42 CFR 84.1134 - Respirator containers; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Respirator containers; minimum requirements. 84.1134 Section 84.1134 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  2. 42 CFR 84.1130 - Respirators; description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Respirators; description. 84.1130 Section 84.1130 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist...

  3. 42 CFR 84.1134 - Respirator containers; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Respirator containers; minimum requirements. 84.1134 Section 84.1134 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  4. 42 CFR 84.1130 - Respirators; description.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Respirators; description. 84.1130 Section 84.1130 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist...

  5. 42 CFR 84.1134 - Respirator containers; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Respirator containers; minimum requirements. 84.1134 Section 84.1134 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  6. 42 CFR 84.1130 - Respirators; description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Respirators; description. 84.1130 Section 84.1130 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist...

  7. 42 CFR 84.1130 - Respirators; description.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Respirators; description. 84.1130 Section 84.1130 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist...

  8. 42 CFR 84.1131 - Respirators; required components.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Respirators; required components. 84.1131 Section 84.1131 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume...

  9. 42 CFR 84.1131 - Respirators; required components.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Respirators; required components. 84.1131 Section 84.1131 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume...

  10. 42 CFR 84.1134 - Respirator containers; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Respirator containers; minimum requirements. 84.1134 Section 84.1134 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  11. 42 CFR 84.1134 - Respirator containers; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Respirator containers; minimum requirements. 84.1134 Section 84.1134 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust...

  12. 42 CFR 84.1131 - Respirators; required components.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Respirators; required components. 84.1131 Section 84.1131 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume...

  13. 42 CFR 84.1131 - Respirators; required components.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Respirators; required components. 84.1131 Section 84.1131 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume...

  14. 42 CFR 84.1131 - Respirators; required components.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Respirators; required components. 84.1131 Section 84.1131 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume...

  15. 42 CFR 84.1130 - Respirators; description.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Respirators; description. 84.1130 Section 84.1130 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist...

  16. Promoting early exposure monitoring for respirable crystalline silica: Taking the laboratory to the mine site

    PubMed Central

    Cauda, Emanuele; Miller, Arthur; Drake, Pamela

    2017-01-01

    The exposure to respirable crystalline silica (RCS) in the mining industry is a recognized occupational hazard. The assessment and monitoring of the exposure to RCS is limited by two main factors: (1) variability of the silica percent in the mining dust and (2) lengthy off-site laboratory analysis of collected samples. The monitoring of respirable dust via traditional or real-time techniques is not adequate. A solution for on-site quantification of RCS in dust samples is being investigated by the Office of Mine Safety and Health Research, a division of the National Institute for Occupational Safety and Health. The use of portable Fourier transform infrared analyzers in conjunction with a direct-on-filter analysis approach is proposed. The progress made so far, the necessary steps in progress, and the application of the monitoring solution to a small data set is presented. When developed, the solution will allow operators to estimate RCS immediately after sampling, resulting in timelier monitoring of RCS for self-assessment of compliance at the end of the shift, more effective engineering monitoring, and better evaluation of control technologies. PMID:26558490

  17. Biopersistent Granular Dust and Chronic Obstructive Pulmonary Disease: A Systematic Review and Meta-Analysis

    PubMed Central

    Brüske, Irene; Thiering, Elisabeth; Heinrich, Joachim; Huster, Katharina; Nowak, Dennis

    2013-01-01

    Objective Applying a systematic review to identify studies eligible for meta-analysis of the association between occupational exposure to inorganic dust and the development of chronic obstructive pulmonary disease (COPD), and conducting a meta-analysis. Data Sources Searches of PubMed and Embase for the time period 1970–2010 yielded 257 cross-sectional and longitudinal studies on people exposed to inorganic dust at the workplace with data on lung function. These studies were independently abstracted and evaluated by two authors; any disagreement was resolved by a third reviewer. Of 55 publications accepted for meta-analysis, 27 investigated the effects of occupational exposure to biopersistent granular dust (bg-dust). Methods A random effects meta-analysis allowed us to provide an estimate of the average exposure effect on spirometric parameters presented in forest plots. Between-study heterogeneity was assessed by using I2 statistics, with I2>25% indicating significant heterogeneity. Publication bias was investigated by visual inspection of funnel plots. The influence of individual studies was assessed by dropping the respective study before pooling study-specific estimates. Results The mean FEV1 of workers exposed to bg-dust was 160 ml lower or 5.7% less than predicted compared to workers with no/low exposure. The risk of an obstructive airway disease—defined as FEV1/FVC < 70%—increased by 7% per 1 mg· m-3 respirable bg-dust. Conclusion Occupational inhalative exposure to bg-dust was associated with a statistically significant decreased FEV1 and FEV1/FVC revealing airway obstruction consistent with COPD. PMID:24278358

  18. Evaluation of an improved prototype mini-baghouse to control the release of respirable crystalline silica from sand movers.

    PubMed

    Alexander, Barbara M; Esswein, Eric J; Gressel, Michael G; Kratzer, Jerry L; Feng, H Amy; Miller, Arthur L; Cauda, Emanuele; Heil, Graeham

    2018-01-01

    The OSHA final rule on respirable crystalline silica (RCS) will require hydraulic fracturing companies to implement engineering controls to limit workers' exposure to RCS. RCS is generated by pneumatic transfer of quartz-containing sand during hydraulic fracturing operations. Chronic inhalation of RCS can lead to serious disease, including silicosis and lung cancer. NIOSH research identified at least seven sources where RCS aerosols were generated at hydraulic fracturing sites. NIOSH researchers developed an engineering control to address one of the largest sources of RCS aerosol generation, RCS escaping from thief hatches on the top of sand movers. The control, the NIOSH Mini-Baghouse Retrofit Assembly (NMBRA), mounts on the thief hatches. Unlike most commercially available engineering controls, the NMBRA has no moving parts and requires no power source. This article details the results of an evaluation of generation 3 of the NMBRA at a sand mine in Arkansas from May 19-21, 2015. During the evaluation, 168 area air samples were collected at 12 locations on and around a sand mover with and without the NMBRA installed. Analytical results for respirable dust and RCS indicated the use of the NMBRA effectively reduced concentrations of both respirable dust and RCS downwind of the thief hatches. Reductions of airborne respirable dust were estimated at 99+%; reductions in airborne RCS ranged from 98-99%. Analysis of bulk samples of the dust showed the likely presence of freshly fractured quartz, a particularly hazardous form of RCS. Use of an improved filter fabric and a larger area of filter cloth led to substantial improvements in filtration and pressures during these trials, as compared to the generation 2 NMBRA. Planned future design enhancements, including a weather cover, will increase the performance and durability of the NMBRA. Future trials are planned to evaluate the long-term operability of the technology.

  19. Concentrations and size distribution of inhalable and respirable dust among sugar industry workers: a pilot study in Khon Kaen, Thailand.

    PubMed

    Sakunkoo, Pornpun; Chaiear, Naesinee; Chaikittiporn, Chalermchai; Sadhra, Steven

    2011-11-01

    There has been very limited information regarding bagasse exposure among workers in sugar industries as well as on health outcomes. The authors determined the occupational exposure of sugar industry workers in Khon Kaen to airborne bagasse dust. The size of the bagasse dust ranged from 0.08 to 9 µm with the highest size concentration of 2.1 to 4.7 µm. The most common size had a geometric mean diameter of 5.2 µm, with a mass concentration of 6.89 mg/m(3)/log µm. The highest mean values of inhalable and respirable dust were found to be 9.29 mg/m(3) from February to April in bagasse storage, 5.12 mg/m(3) from May to September, and 4.12 mg/m(3) from October to January. Inhalable dust concentrations were 0.33, 0.47, and 0.41 mg/m(3), respectively. Workers are likely to be exposed to high concentrations of bagasse dust and are at risk of respiratory diseases. Preventive measures, both in the form of engineering designs and personal protective devices, should be implemented.

  20. Health-hazard evaluation report HETA 83-391-1683, Continental Coffee Products Company, Houston, Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, S.J.; Markel, H.L.; Morawetz, J.S.

    1986-04-01

    The International Chemical Workers Union requested an evaluation be made of the health status of employees at the Continental Coffee Products Company, Houston, Texas with particular attention given to potential exposure to pesticide residues on imported coffee beans. Analysis of air samples revealed the following concentration ranges: 29 personal respirable-dust samples ranging from 0.03 to 2.03 milligrams/cubic meter (mg/m3); 27 of 28 personal total dust samples, 0.09 to 2.65 mg/m3; four area respirable-dust samples, 0.11 to 0.53 mg/m3; and four area total dust samples, 0.16 to 2.39 mg/m3. Pesticide exposures were significantly below acceptable daily intakes. The authors conclude thatmore » it would not be expected that employees would be exposed to pesticide levels posing an appreciable threat to health. Recommendations were made to increase the use of local exhaust ventilation; to improve work practices to reduce generation of dust and accumulation; increase ventilation in the basement re-mix operation; and train employees toward the understanding of potential hazards and their role in controlling dust.« less

  1. Instituting a filtration/pressurization system to reduce dust concentrations in a control room at a mineral processing plant

    PubMed Central

    Noll, J.; Cecala, A.; Hummer, J.

    2016-01-01

    The National Institute for Occupational Safety and Health has observed that many control rooms and operator compartments in the U.S. mining industry do not have filtration systems capable of maintaining low dust concentrations in these areas. In this study at a mineral processing plant, to reduce respirable dust concentrations in a control room that had no cleaning system for intake air, a filtration and pressurization system originally designed for enclosed cabs was modified and installed. This system was composed of two filtering units: one to filter outside air and one to filter and recirculate the air inside the control room. Eighty-seven percent of submicrometer particles were reduced by the system under static conditions. This means that greater than 87 percent of respirable dust particles should be reduced as the particle-size distribution of respirable dust particles is greater than that of submicrometer particles, and filtration systems usually are more efficient in capturing the larger particles. A positive pressure near 0.02 inches of water gauge was produced, which is an important component of an effective system and minimizes the entry of particles, such as dust, into the room. The intake airflow was around 118 cfm, greater than the airflow suggested by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) for acceptable indoor air quality. After one year, the loading of the filter caused the airflow to decrease to 80 cfm, which still produces acceptable indoor air quality. Due to the loading of the filters, the reduction efficiency for submicrometer particles under static conditions increased to 94 percent from 87 percent. PMID:26834293

  2. Relationships between Personal Measurements of 'Total' Dust, Respirable, Thoracic, and Inhalable Aerosol Fractions in the Cement Production Industry.

    PubMed

    Notø, Hilde P; Nordby, Karl-Christian; Eduard, Wijnand

    2016-05-01

    The aims of this study were to examine the relationships and establish conversion factors between 'total' dust, respirable, thoracic, and inhalable aerosol fractions measured by parallel personal sampling on workers from the production departments of cement plants. 'Total' dust in this study refers to aerosol sampled by the closed face 37-mm Millipore filter cassette. Side-by-side personal measurements of 'total' dust and respirable, thoracic, and inhalable aerosol fractions were performed on workers in 17 European and Turkish cement plants. Simple linear and mixed model regressions were used to model the associations between the samplers. The total number of personal samples collected on 141 workers was 512. Of these 8.4% were excluded leaving 469 for statistical analysis. The different aerosol fractions contained from 90 to 130 measurements and-side-by side measurements of all four aerosol fractions were collected on 72 workers.The median ratios between observed results of the respirable, 'total' dust, and inhalable fractions relative to the thoracic aerosol fractions were 0.51, 2.4, and 5.9 respectively. The ratios between the samplers were not constant over the measured concentration range and were best described by regression models. Job type, position of samplers on left or right shoulder and plant had no substantial effect on the ratios. The ratios between aerosol fractions changed with different air concentrations. Conversion models for estimation of the fractions were established. These models explained a high proportion of the variance (74-91%) indicating that they are useful for the estimation of concentrations based on measurements of a different aerosol fraction. The calculated uncertainties at most observed concentrations were below 30% which is acceptable for comparison with limit values (EN 482, 2012). The cement industry will therefore be able to predict the health related aerosol fractions from their former or future measurements of one of the fractions. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. 15 years of monitoring occupational exposure to respirable dust and quartz within the European industrial minerals sector.

    PubMed

    Zilaout, Hicham; Vlaanderen, Jelle; Houba, Remko; Kromhout, Hans

    2017-07-01

    In 2000, a prospective Dust Monitoring Program (DMP) was started in which measurements of worker's exposure to respirable dust and quartz are collected in member companies from the European Industrial Minerals Association (IMA-Europe). After 15 years, the resulting IMA-DMP database allows a detailed overview of exposure levels of respirable dust and quartz over time within this industrial sector. Our aim is to describe the IMA-DMP and the current state of the corresponding database which due to continuation of the IMA-DMP is still growing. The future use of the database will also be highlighted including its utility for the industrial minerals producing sector. Exposure data are being obtained following a common protocol including a standardized sampling strategy, standardized sampling and analytical methods and a data management system. Following strict quality control procedures, exposure data are consequently added to a central database. The data comprises personal exposure measurements including auxiliary information on work and other conditions during sampling. Currently, the IMA-DMP database consists of almost 28,000 personal measurements which have been performed from 2000 until 2015 representing 29 half-yearly sampling campaigns. The exposure data have been collected from 160 different worksites owned by 35 industrial mineral companies and comes from 23 European countries and approximately 5000 workers. The IMA-DMP database provides the European minerals sector with reliable data regarding worker personal exposures to respirable dust and quartz. The database can be used as a powerful tool to address outstanding scientific issues on long-term exposure trends and exposure variability, and importantly, as a surveillance tool to evaluate exposure control measures. The database will be valuable for future epidemiological studies on respiratory health effects and will allow for estimation of quantitative exposure response relationships. Copyright © 2017 The Authors. Published by Elsevier GmbH.. All rights reserved.

  4. Occupational exposure to crystalline silica at Alberta work sites.

    PubMed

    Radnoff, Diane; Todor, Maria S; Beach, Jeremy

    2014-01-01

    Although crystalline silica has been recognized as a health hazard for many years, it is still encountered in many work environments. Numerous studies have revealed an association between exposure to respirable crystalline silica and the development of silicosis and other lung diseases including lung cancer. Alberta Jobs, Skills, Training and Labour conducted a project to evaluate exposure to crystalline silica at a total of 40 work sites across 13 industries. Total airborne respirable dust and respirable crystalline silica concentrations were quite variable, but there was a potential to exceed the Alberta Occupational Exposure Limit (OEL) of 0.025 mg/m(3) for respirable crystalline silica at many of the work sites evaluated. The industries with the highest potentials for overexposure occurred in sand and mineral processing (GM 0.090 mg/m(3)), followed by new commercial building construction (GM 0.055 mg/m(3)), aggregate mining and crushing (GM 0.048 mg/m(3)), abrasive blasting (GM 0.027 mg/m(3)), and demolition (GM 0.027 mg/m(3)). For worker occupations, geometric mean exposure ranged from 0.105 mg/m(3) (brick layer/mason/concrete cutting) to 0.008 mg/m(3) (dispatcher/shipping, administration). Potential for GM exposure exceeding the OEL was identified in a number of occupations where it was not expected, such as electricians, carpenters and painters. These exposures were generally related to the specific task the worker was doing, or arose from incidental exposure from other activities at the work site. The results indicate that where there is a potential for activities producing airborne respirable crystalline silica, it is critical that the employer include all worker occupations at the work site in their hazard assessment. There appears to be a relationship between airborne total respirable dust concentration and total respirable dust concentrations, but further study is require to fully characterize this relationship. If this relationship holds true, it may provide a useful hazard assessment tool for employers by which the potential for exposure to airborne respirable silica at the work site can be more easily estimated.

  5. 75 FR 73995 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    ... http://www.msha.gov/REGS/FEDREG/PROPOSED/2010PROP/2010-25249.pdf . The proposed rule would revise the.../PROPOSED/2010PROP/2010-25249.pdf . The following error in the preamble to the proposed rule is corrected to...

  6. Physico-chemical characterization of grain dust in storage air of Bangalore.

    PubMed

    Mukherjee, A K; Nag, D P; Kakde, Y; Babu, K R; Prdkash, M N; Rao, S R

    1998-06-01

    An Anderson personal cascade impactor was used to study the particle mass size distribution in the storage air of two major grain storage centers in Bangalore. Dust levels in storage air as well as the personal exposures of workers were determined along with a detailed study on the particle size distribution. Protein and carbohydrate content of the dust were also determined respectively in the phosphate buffer saline (PBS) and water extracts by using the standard analytical techniques. Personal exposures in both of the grain storage centers have been found to be much above the limit prescribed by ACGIH (1995-96). But the results of particle size analysis showed a higher particle mass distribution in the non-respirable size range. The mass median diameters (MMD) of the storage air particulate of both the centers were found to be beyond the respirable range. Presence of protein and carbohydrate in the storage air dust is indicative of the existence of glyco-proteins, mostly of membrane origin.

  7. Performance of high flow rate samplers for respirable particle collection.

    PubMed

    Lee, Taekhee; Kim, Seung Won; Chisholm, William P; Slaven, James; Harper, Martin

    2010-08-01

    The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m(-3) in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins-Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size ((50)d(ae)) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 microm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2-11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 microm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.

  8. Performance of High Flow Rate Samplers for Respirable Particle Collection

    PubMed Central

    Lee, Taekhee; Kim, Seung Won; Chisholm, William P.; Slaven, James; Harper, Martin

    2010-01-01

    The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m−3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 μm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 μm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted. PMID:20660144

  9. Indoor and outdoor PM10 levels at schools located near mine dumps in Gauteng and North West Provinces, South Africa.

    PubMed

    Nkosi, Vusumuzi; Wichmann, Janine; Voyi, Kuku

    2017-01-06

    Few studies in South Africa have investigated the exposure of asthmatic learners to indoor and outdoor air pollution at schools. This study compared outdoor PM 10 and SO 2 exposure levels in exposed (1-2 km from gold mine dumps) and unexposed schools (5 km or more from gold mine dumps). It also examined exposure of asthmatic children to indoor respirable dust at exposed and unexposed schools. The study was conducted between 1 and 31 October 2012 in five schools from exposed and five from unexposed communities. Outdoor PM 10 and SO 2 levels were measured for 8-h at each school. Ten asthmatic learners were randomly selected from each school for 8-h personal respirable dust sampling during school hours. The level of outdoor PM 10 for exposed was 16.42 vs. 11.47 mg.m -3 for the unexposed communities (p < 0.001). The outdoor SO 2 for exposed was 0.02 ppb vs. 0.01 ppb for unexposed communities (p < 0.001). Indoor respirable dust in the classroom differed significantly between exposed (0.17 mg.m -3 ) vs. unexposed (0.01 mg.m -3 ) children with asthma at each school (p < 0.001). The significant differences between exposed and unexposed schools could reveal a serious potential health hazard for school children, although they were within the South African Air Quality Standards' set by the Department of Environmental Affairs. The indoor respirable dust levels in exposed schools could have an impact on children with asthma, as they were significantly higher than the unexposed schools, although there are no published standards for environmental exposure for children with asthma.

  10. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    PubMed

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p < 0.001). The breathing resistances of the unused FFRs and dust masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p < 0.001). After dust loading there was a significant difference between the BR caused by the ARD dust layer on each FFR and dust mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values < 5% and quality factors (0.26 and 0.33) comparable to those obtained for the two FFRs (0.23 and 0.31). However, the remaining three dust masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  11. 42 CFR 84.1148 - Tests for respirators designed for respiratory protection against more than one type of...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2010-10-01 2010-10-01 false Tests for respirators designed for respiratory...

  12. 42 CFR 84.1148 - Tests for respirators designed for respiratory protection against more than one type of...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2013-10-01 2013-10-01 false Tests for respirators designed for respiratory...

  13. 42 CFR 84.1148 - Tests for respirators designed for respiratory protection against more than one type of...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2012-10-01 2012-10-01 false Tests for respirators designed for respiratory...

  14. 42 CFR 84.1148 - Tests for respirators designed for respiratory protection against more than one type of...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2011-10-01 2011-10-01 false Tests for respirators designed for respiratory...

  15. 42 CFR 84.1148 - Tests for respirators designed for respiratory protection against more than one type of...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Dust, Fume, and Mist; Pesticide... 42 Public Health 1 2014-10-01 2014-10-01 false Tests for respirators designed for respiratory...

  16. 77 FR 38323 - Proposed Extension of Existing Information Collection; Respirable Coal Mine Dust Sampling

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ...-9440 (voice); or 202-693-9441 (facsimile). SUPPLEMENTARY INFORMATION: I. Background The title of the..., silicosis, and chronic bronchitis, known collectively as ``black lung.'' These diseases are debilitating and... dust levels since 1970 and, consequently, the prevalence rate of black lung among coal miners, severe...

  17. 30 CFR 90.220 - Status change reports.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Procedures § 90.201 Sampling; general and technical requirements. (a) An approved coal mine dust personal sampler unit (CMDPSU) shall be used to take samples of the concentration of respirable coal mine dust in...

  18. Dustiness of Fine and Nanoscale Powders

    PubMed Central

    Evans, Douglas E.; Baron, Paul A.

    2013-01-01

    Dustiness may be defined as the propensity of a powder to form airborne dust by a prescribed mechanical stimulus; dustiness testing is typically intended to replicate mechanisms of dust generation encountered in workplaces. A novel dustiness testing device, developed for pharmaceutical application, was evaluated in the dustiness investigation of 27 fine and nanoscale powders. The device efficiently dispersed small (mg) quantities of a wide variety of fine and nanoscale powders, into a small sampling chamber. Measurements consisted of gravimetrically determined total and respirable dustiness. The following materials were studied: single and multiwalled carbon nanotubes, carbon nanofibers, and carbon blacks; fumed oxides of titanium, aluminum, silicon, and cerium; metallic nanoparticles (nickel, cobalt, manganese, and silver) silicon carbide, Arizona road dust; nanoclays; and lithium titanate. Both the total and respirable dustiness spanned two orders of magnitude (0.3–37.9% and 0.1–31.8% of the predispersed test powders, respectively). For many powders, a significant respirable dustiness was observed. For most powders studied, the respirable dustiness accounted for approximately one-third of the total dustiness. It is believed that this relationship holds for many fine and nanoscale test powders (i.e. those primarily selected for this study), but may not hold for coarse powders. Neither total nor respirable dustiness was found to be correlated with BET surface area, therefore dustiness is not determined by primary particle size. For a subset of test powders, aerodynamic particle size distributions by number were measured (with an electrical low-pressure impactor and an aerodynamic particle sizer). Particle size modes ranged from approximately 300nm to several micrometers, but no modes below 100nm, were observed. It is therefore unlikely that these materials would exhibit a substantial sub-100nm particle contribution in a workplace. PMID:23065675

  19. Hazard-evaluation and technical-assistance report No. ta-77-68, McDaniel Art Studio, Cincinnati, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kronoveter, K.J.

    1978-06-01

    In response to a request from the McDaniel Art Studio, located in Cincinnati, Ohio, an investigation was made of possible hazardous working conditions at the site, specifically the exposure to dust during sculpturing. Air sampling revealed potential dust exposures as high as 50 mg/m3 of total dust while using a powered disc grinder to sculpt. The sculpting process involved grinding with a 6-inch electric disc grinder or using such hand tools as files and chisels. The sculptor used primarily limestone, marble, talc, and onyx, working about 6 hours per day. The talc sculpting stone showed the presence of asbestos onmore » bulk analysis. The sculptor wore safety glasses with side shields and an appropriate, approved respirator. An industrial vacuum cleaner was used for dust cleanup. The author recommends that the sculptor continue to use the NIOSH approved respirator and that, if possible, the disc grinder not be used on potential asbestos sources such as serpentine and talc. Wet working of the stone would reduce the dust levels significantly. Several precautionary measures are listed from a publication dealing with the health risks associated with common art and hobby materials.« less

  20. Evaluation of Diffuse Reflection Infrared Spectrometry for End-of-Shift Measurement of α-quartz in Coal Dust Samples

    PubMed Central

    Miller, Arthur L.; Murphy, Nathaniel C.; Bayman, Sean J.; Briggs, Zachary P.; Kilpatrick, Andrew D.; Quinn, Courtney A.; Wadas, Mackenzie R.; Cauda, Emanuele G.; Griffiths, Peter R.

    2015-01-01

    The inhalation of toxic substances is a major threat to the health of miners, and dust containing respirable crystalline silica (α-quartz) is of particular concern, due to the recent rise in cases of coal workers’ pneumoconiosis and silicosis in some U.S. mining regions. Currently, there is no field-portable instrument that can measure airborne α-quartz and give miners timely feedback on their exposure. The U.S. National Institute for Occupational Safety and Health (NIOSH) is therefore conducting studies to investigate technologies capable of end-of-shift or real-time measurement of airborne quartz. The present study focuses on the potential application of Fourier transform infrared (FT-IR) spectrometry conducted in the diffuse reflection (DR) mode as a technique for measuring α-quartz in respirable mine dust. A DR accessory was used to analyze lab-generated respirable samples of Min-U-Sil 5 (which contains more than 90% α-quartz) and coal dust, at mass loadings in the ranges of 100–600 μg and 600–5300 μg, respectively. The dust samples were deposited onto three different types of filters, borosilicate fiberglass, nylon, and polyvinyl chloride (PVC). The reflectance, R, was calculated by the ratio of a blank filter and a filter with deposited mine dust. Results suggest that for coal and pure quartz dusts deposited on 37 mm PVC filters, measurements of −log R correlate linearly with known amounts of quartz on filters, with R2 values of approximately 0.99 and 0.94, respectively, for samples loaded up to ~4000 μg. Additional tests were conducted to measure quartz in coal dusts deposited onto the borosilicate fiberglass and nylon filter media used in the NIOSH-developed Personal Dust Monitor (PDM). The nylon filter was shown to be amenable to DR analysis, but quantification of quartz is more accurate when the filter is “free,” as opposed to being mounted in the PDM filter holder. The borosilicate fiberglass filters were shown to produce excessive interference, making quartz quantification impossible. It was concluded that, while the DR/FT-IR method is potentially useful for on-filter measurement of quartz in dust samples, the use of PVC filters produced the most accurate results. PMID:25636081

  1. Evaluation of Diffuse Reflection Infrared Spectrometry for End-of-Shift Measurement of α-quartz in Coal Dust Samples.

    PubMed

    Miller, Arthur L; Murphy, Nathaniel C; Bayman, Sean J; Briggs, Zachary P; Kilpatrick, Andrew D; Quinn, Courtney A; Wadas, Mackenzie R; Cauda, Emanuele G; Griffiths, Peter R

    2015-01-01

    The inhalation of toxic substances is a major threat to the health of miners, and dust containing respirable crystalline silica (α-quartz) is of particular concern, due to the recent rise in cases of coal workers' pneumoconiosis and silicosis in some U.S. mining regions. Currently, there is no field-portable instrument that can measure airborne α-quartz and give miners timely feedback on their exposure. The U.S. National Institute for Occupational Safety and Health (NIOSH) is therefore conducting studies to investigate technologies capable of end-of-shift or real-time measurement of airborne quartz. The present study focuses on the potential application of Fourier transform infrared (FT-IR) spectrometry conducted in the diffuse reflection (DR) mode as a technique for measuring α-quartz in respirable mine dust. A DR accessory was used to analyze lab-generated respirable samples of Min-U-Sil 5 (which contains more than 90% α-quartz) and coal dust, at mass loadings in the ranges of 100-600 μg and 600-5300 μg, respectively. The dust samples were deposited onto three different types of filters, borosilicate fiberglass, nylon, and polyvinyl chloride (PVC). The reflectance, R, was calculated by the ratio of a blank filter and a filter with deposited mine dust. Results suggest that for coal and pure quartz dusts deposited on 37 mm PVC filters, measurements of -log R correlate linearly with known amounts of quartz on filters, with R(2) values of approximately 0.99 and 0.94, respectively, for samples loaded up to ∼4000 μg. Additional tests were conducted to measure quartz in coal dusts deposited onto the borosilicate fiberglass and nylon filter media used in the NIOSH-developed Personal Dust Monitor (PDM). The nylon filter was shown to be amenable to DR analysis, but quantification of quartz is more accurate when the filter is "free," as opposed to being mounted in the PDM filter holder. The borosilicate fiberglass filters were shown to produce excessive interference, making quartz quantification impossible. It was concluded that, while the DR/FT-IR method is potentially useful for on-filter measurement of quartz in dust samples, the use of PVC filters produced the most accurate results.

  2. Assessing exposure risk for dust storm events-associated lung function decrement in asthmatics and implications for control

    NASA Astrophysics Data System (ADS)

    Hsieh, Nan-Hung; Liao, Chung-Min

    2013-04-01

    Asian dust storms (ADS) events are seasonally-based meteorological phenomena that exacerbate chronic respiratory diseases. The purpose of this study was to assess human health risk from airborne dust exposure during ADS events in Taiwan. A probabilistic risk assessment framework was developed based on exposure and experimental data to quantify ADS events induced lung function decrement. The study reanalyzed experimental data from aerosol challenge in asthmatic individuals to construct the dose-response relationship between inhaled dust aerosol dose and decreasing percentage of forced expiratory volume in 1 s (%FEV1). An empirical lung deposition model was used to predict deposition fraction for size specific dust aerosols in pulmonary regions. The toxicokinetic and toxicodynamic models were used to simulate dust aerosols binding kinetics in lung airway in that %FEV1 change was also predicted. The mask respirators were applied to control the inhaled dose under dust aerosols exposure. Our results found that only 2% probability the mild ADS events were likely to cause %FEV1 decrement higher than 5%. There were 50% probability of decreasing %FEV1 exceeding 16.9, 18.9, and 7.1% in north, center, and south Taiwan under severe ADS events, respectively. Our result implicates that the use of activated carbon of mask respirators has the best efficacy for reducing inhaled dust aerosol dose, by which the %FEV1 decrement can be reduced up to less than 1%.

  3. Field evaluation of an engineering control for respirable crystalline silica exposures during mortar removal.

    PubMed

    Collingwood, Scott; Heitbrink, William A

    2007-11-01

    During mortar removal with a right angle grinder, a building renovation process known as "tuck pointing," worker exposures to respirable crystalline silica can be as high as 5 mg/m(3), 100 times the recommended exposure limit developed by the National Institute for Occupational Safety and Health. To reduce the risk of silicosis among these workers, a vacuum cleaner can be used to exhaust 80 ft(3)/min (2.26 m(3)/min) from a hood mounted on the grinder. Field trials examined the ability of vacuum cleaners to maintain adequate exhaust ventilation rates and measure exposure outcomes when using this engineering control. These field trials involved task-based exposure measurement of respirable dust and crystalline silica exposures during mortar removal. These measurements were compared with published exposure data. Vacuum cleaner airflows were obtained by measuring and digitally logging vacuum cleaner static pressure at the inlet to the vacuum cleaner motor. Static pressures were converted to airflows based on experimentally determined fan curves. In two cases, video exposure monitoring was conducted to study the relationship between worker activities and dust exposure. Worker activities were video taped concurrent with aerosol photometer measurement of dust exposure and vacuum cleaner static pressure as a measure of airflow. During these field trials, respirable crystalline silica exposures for 22 samples had a geometric mean of 0.06 mg/m(3) and a range of less than 0.01 to 0.86 mg/m(3). For three other studies, respirable crystalline silica exposures during mortar removal have a geometric means of 1.1 to 0.35. Although this field study documented noticeably less exposure to crystalline silica, video exposure monitoring found that the local exhaust ventilation provided incomplete dust control due to low exhaust flow rates, certain work practices, and missing mortar. Vacuum cleaner airflow decrease had a range of 3 to 0.4 ft(3)/min (0.08 to 0.01 m(3)/sec(2)) over a range of vacuum cleaners, hose diameters, and hose lengths. To control worker exposure to respirable crystalline silica, local exhaust ventilation needs to be incorporated into a comprehensive silica control program that includes respiratory protection, worker training, and local exhaust ventilation.

  4. Case cluster of pneumoconiosis at a coal slag processing facility.

    PubMed

    Fagan, Kathleen M; Cropsey, Erin B; Armstrong, Jenna L

    2015-05-01

    During an inspection by the Occupational Safety and Health Administration (OSHA) of a small coal slag processing plant with 12 current workers, four cases of pneumoconiosis were identified among former workers. The OSHA investigation consisted of industrial hygiene sampling, a review of medical records, and case interviews. Some personal sampling measurements exceeded the OSHA Permissible Exposure Limit (PEL) for total dust exposures of 15 mg/m(3), and the measured respirable silica exposure of 0.043 mg/m(3), although below OSHA's current PEL for respirable dust containing silica, was above the American Conference of Governmental Industrial Hygienists' Threshold Limit Value (TLV). Chest x-rays for all four workers identified small opacities consistent with pneumoconiosis. This is the first known report of lung disease in workers processing coal slag and raises concerns for workers exposed to coal slag dust. © 2015 Wiley Periodicals, Inc.

  5. Epidemiological study of respiratory disease in workers exposed to polyvinylchloride dust.

    PubMed Central

    Soutar, C A; Copland, L H; Thornley, P E; Hurley, J F; Ottery, J; Adams, W G; Bennett, B

    1980-01-01

    The respiratory health of workers exposed to polyvinylchloride (PVC) dust has been investigated in 818 men sampled from the work force of a factory manufacturing PVC. In a cross-sectional survey, the lung function and prevalences of respiratory symptoms and chest radiographic abnormalities were compared with estimates of individual PVC dust exposures based on detailed occupational histories and current measurements of respirable PVC dust. Complaints of slight exertional dyspnoea were associated with PVC dust exposure, though age and smoking effects were much stronger. The forced expired volume in one second (FEV1) and forced vital capacity (FVC) were inversely related to dust exposure after age, height, and smoking effects had been taken into account. This effect was seen principally in cigarette smokers, and there was suggestive evidence that PVC dust exposure and cigarette smoking interacted in the reduction of FEV1 and FVC. Gas transfer factor was not related to dust exposure. The chest radiographs were read according to the ILO U/C classification by three experienced readers. One reader recorded a low prevalence of small rounded opacities, and these were not related to age or dust exposure. Another reader recorded a higher prevalence of small rounded opacities category 0/1 or more, and these were related to age but not to dust exposure. The third reader recorded the highest prevalence of small rounded opacities (though none greater than category 1/1), and these were independently related both to age and to PVC dust exposure, indicating an effect of PVC dust on the appearance of the chest radiography. These appearances were so slight that only the higher sensitivity of this reader in the interpretation of profusion of small rounded opacities on the ILO U/C scale enabled detection of this effect of PVC dust. In conclusion, exposure to PVC dust is associated with some deterioration of lung function, slight abnormalities of the chest radiograph, and complaints of slight dyspnoea. The mean decline in FEV1 associated with the average dust exposure experienced in the study was small, though some of the men with higher dust exposures may have suffered clinically important loss of lung function as a result of their occupation. PMID:7444838

  6. [Effect of humidity and temperature on filter and gravimetric measurement of ambient particulate matter in a balance room].

    PubMed

    Su, Wen-jin; Wang, Li-min; Weng, Shao-fan; Wang, Hai-jiao; Du, Li-li; Liu, Yue-wei; Yang, Lei; Chen, Wei-hong

    2008-04-01

    To assess the effects of the alteration of humidity and (or) temperature on weight of filters without and with ambient particulate matter in a balance room. The mass of blank dust sampling filters were weighed under (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively, with the humidity varying from 35% relative humidity (RH) to 100% RH in a balance room. Then the blank filters were divided into two groups and were used to sample total dust and respirable dust. After sampling, the loaded filters were re-weighed under above conditions and the mass difference before and after the sampling were compared and analyzed. The vibration of the average mass of filters varied from 0.10 to 0.13 mg and from 0.06 to 0.09 mg under the temperatures of (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively; When both the temperature and humidity changed, it varied from 0.12 to 0.16 mg. The deviation of average mass difference ranged from 0.07 to 0.10 mg and from 0.04 to 0.08 mg under the two temperatures mentioned above; When both the temperature and humidity changed, it varied from 0.09 to 0.14 mg. The average mass of blank filters and loaded filters were all positively correlated with the change of humidity (P < 0.01). No effects of humidity on the average mass difference of the loaded filters were observed. The average mass differences of loaded filters and blank filters under (18 +/- 1) degrees C were significantly higher than that under (28 +/- 1) degrees C (P < 0.01) when humidity was not changed. The alteration of humidity and (or) temperature in a balance room attributes to the deviation of the measurement of the mass of filters and thus affects the gravimetric measurements of ambient particulate matter.

  7. Risk of Adverse Health and Performance Effects of Celestial Dust Exposure

    NASA Technical Reports Server (NTRS)

    Scully, Robert R.; Meyers, Valerie E.

    2015-01-01

    Crew members can be directly exposed to celestial dust in several ways. After crew members perform extravehicular activities (EVAs), they may introduce into the habitat dust that will have collected on spacesuits and boots. Cleaning of the suits between EVAs and changing of the Environmental Control Life Support System filters are other operations that could result in direct exposure to celestial dusts. In addition, if the spacesuits used in exploration missions abrade the skin, as current EVA suits have, then contact with these wounds would provide a source of exposure. Further, if celestial dusts gain access to a suit's interior, as was the case during the Apollo missions, the dust could serve as an additional source of abrasions or enhance suit-induced injuries. When a crew leaves the surface of a celestial body and returns to microgravity, the dust that is introduced into the return vehicle will "float," thus increasing the opportunity for ocular and respiratory injury. Because the features of the respirable fraction of lunar dusts indicate they could be toxic to humans, NASA conducted several studies utilizing lunar dust simulants and authentic lunar dust to determine the unique properties of lunar dust that affect physiology, assess the dermal and ocular irritancy of the dust, and establish a permissible exposure limit for episodic exposure to airborne lunar dust during missions that would involve no more than 6 months stay on the lunar surface. Studies, with authentic lunar soils from both highland (Apollo 16) and mare (Apollo17) regions demonstrated that the lunar soil is highly abrasive to a high fidelity model of human skin. Studies of lunar dust returned during the Apollo 14 mission from an area of the moon in which the soils were comprised of mineral constituents from both major geological regions (highlands and mares regions) demonstrated only minimal ocular irritancy, and pulmonary toxicity that was less than the highly toxic terrestrial crystalline silica (Permissible Exposure Limit [PEL] 0.05 mg/m3) but more toxic than the nuisance dust titanium dioxide (TiO2 [PEL 5.0 mg/m3]). A PEL for episodic exposure to airborne lunar dust during a six-month stay on the lunar surface was established, in consultation with an independent, extramural panel of expert pulmonary toxicologists, at 0.3 mg/m3. The PEL provided for lunar dust is limited to the conditions and exposure specified therefore additional research remains to be accomplished with lunar dust to further address the issues of activation, address other areas of more unique lunar geology (Glotch et al., 2010; Greenhagen et al., 2010), examine potential toxicological effects of inhaled or ingested dust upon other organ systems, such cardiovascular, nervous systems, and examine effects of acute exposure to massive doses of dust such as may occur during off-nominal situations. Work to support the establishment of PELs for Martian dust and dusts of asteroids remains to be accomplished. The literature that describes health effects of exposure to toxic terrestrial dusts provides substantial basis for concern that prolonged exposure to respirable celestial dust could be detrimental to human health. Celestial bodies where a substantial portion of the dust is in the respirable range or where the dusts have large reactive surface areas or contain transition metals or volatile organics, represent greater risks of adverse effects from exposure to the dust. It is possible that in addition to adverse effects to the respiratory system, inhalation and ingestion of celestial dusts could pose risks to other systems

  8. Evaluation of Dust Exposure among the Workers in Agricultural Industries in North-East India.

    PubMed

    Dewangan, Krishna N; Patil, Mahesh R

    2015-11-01

    This study aims to quantify dust exposure among the workers in four different industrial settings: rice mills, flour mills, oil mills, and tea factories and to compare the obtained data with the permissible exposure limit (PEL) of Indian Union Ministry of Labour as well as to compare the dust exposure across activities and seasons. RespiCon(TM) particle sampler was used for collecting dust concentration in the breathing zone of the workers. In total, 149 workers participated in the study and 204 samples were collected. Samples were collected in the vicinity of different processing operations. Samples in the rice mills were collected for two consecutive years in two seasons; however samples from other industries were collected for 1 year. The results indicate that geometric mean (GM) of dust exposure was significantly (P < 0.0001) different among industrial settings. Respirable dust were 8.22, 5.76, 2.98, and 6.34mg m(-3) and total dust exposure were 81.05, 111.02, 56.68, and 39.85mg m(-3) in the rice mills, oil mills, flour mills, and tea factories, respectively. Considerable variations in dust exposure were observed in different activities in the rice and oil mills; however variation was relatively less in the flour mills and tea factories. In the rice mills, dust concentration was higher in winter than those obtained in autumn and it is significantly different (P < 0.05) for inhalable dust and total dust. Positive correlation was obtained in thoracic dust (r (2) = 0.94) and inhalable dust (r (2) = 0.97) with total dust and thoracic dust with inhalable dust (r (2) = 0.89). The results show that majority of the workers are exposed to higher level of respirable dust as compared to the PEL, while total dust exposure to all the workers were higher than the PEL; thus, immediate reduction of dust exposure among the workers is necessary for preventing respiratory system impairment. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  9. Health-hazard evaluation determination report No. 75-181-287, Fibreboard Corporation, Stockton, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okawa, M.T.

    1976-05-01

    Employees in the Litho Department of the Fibreboard Corporation Plant in Stockton, California are not found to be exposed to toxic concentrations of dusting powders, but are exposed to airborne dust levels from the powders which exceed the State of California OSHA standard and the threshold limits for nuisance dust. Safety recommendations include servicing of exhaust ventilation systems regularly, vacuum cleaning instead of dry sweeping, and making NIOSH Certified Respirators available whenever needed.

  10. The influence of coal physical and mechanical properties and mining energy consumption factor on airborne respirable dust level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koziel, A.; Malec, M.; Wardas, E.

    1999-07-01

    The fact that there are not any explicitly defined relationships describing the influence of physical and mechanical properties of coal and of energy consumption factor on dust level prompted Polish and American investigators to carry out a joint research project within the framework of the US-Poland Maria Sklodowska-Curie Joint Fund II. The paper presents methods used to perform tests under laboratory conditions at the Pittsburgh Research Laboratory as well as under real conditions in the course of coal cutting in Polish coal mines. Measuring systems and results of the tests are described. The analysis carried out has provided a basismore » for determining the influence of specified operational parameters, i.e., coal compression strength R{sub c}, coal cuttability factor A, energy consumption factor of mining E{sub uc}, load of cutting drums as well as of laboratory parameters, i.e., grindability, coal breakage characteristics (product size distribution), moisture content, volatile and fixed carbon content, specific energy of crushing on a level of generated dust (total dust, specific dust and airborne respirable dust). The effect of technical parameters, i.e., face height, airflow velocity in a face, amount and pressure of water in spraying systems of longwall shearers, depth of cut taken by a cutting drum and application of powered cowls on dust level under operating conditions are also presented. Results of the tests made it possible to work out guidelines relating to methods and technology for effective reduction of dust emission on longwall faces.« less

  11. Occupational exposure to carbon black in its manufacture.

    PubMed

    Gardiner, K; Trethowan, W N; Harrington, J M; Calvert, I A; Glass, D C

    1992-10-01

    Carbon black is manufactured by the vapour phase pyrolysis of heavy aromatic hydrocarbon feedstocks. Its manufacture is worldwide and the majority of its production is for use in the rubber industry especially tyre manufacture. Its carbonaceous nature has led many to investigate the occurrence of exposure-related medical conditions. To quantify any such relationships, it is necessary to assess exposure accurately. As part of such an epidemiological investigation survey involving the measurement both of respirable and of total inhalable carbon black was undertaken in 18 plants in seven European countries between mid-1987 and mid-1989. A total of 1298 respirable samples (SIMPEDS cyclone) and 1317 total inhalable samples (IOM head) were taken and deemed of sufficient quality for inclusion in the study. The distributions of the time-weighted average values were assessed and found to be best described by a log-normal distribution, and so exposure is characterized by geometric means and standard deviations. The data are presented in terms of 13 separate job titles for both dust fractions and shows a wide variation between job titles, with the highest mean exposure experienced by the site cleaners, and 30% of the samples taken from the warehouse packers being in excess of the relevant countries' occupational exposure limits for total inhalable dust. The quality and extent of this data allows both for comparison with exposure standards and for generation of occupational exposure indices, which will be presented in another paper (Gardiner et al., in preparation).

  12. A Cross-Sectional Study of the Cardiovascular Effects of Welding Fumes.

    PubMed

    Li, Huiqi; Hedmer, Maria; Kåredal, Monica; Björk, Jonas; Stockfelt, Leo; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-01-01

    Occupational exposure to particulate air pollution has been associated with an increased risk of cardiovascular disease. However, the risk to welders working today remains unclear. We aimed to elucidate the cardiovascular effects of exposure to welding fumes. In a cross-sectional study, structured interviews and biological sampling were conducted for 101 welders and 127 controls (all non-smoking males) from southern Sweden. Personal breathing zone sampling of respirable dust was performed. Blood pressure (BP) and endothelial function (using peripheral arterial tonometry) were measured. Plasma and serum samples were collected from peripheral blood for measurement of C-reactive protein, low-density lipoprotein, homocysteine, serum amyloid A, and cytokines. Welders were exposed to 10-fold higher levels of particles than controls. Welders had significantly higher BP compared to controls, an average of 5 mm Hg higher systolic and diastolic BP (P ≤ 0.001). IL-8 was 3.4 ng/L higher in welders (P=0.010). Years working as a welder were significantly associated with increased BP (β=0.35, 95%CI 0.13 - 0.58, P=0.0024 for systolic BP; β=0.32, 95%CI 0.16 - 0.48, P<0.001 for diastolic BP, adjusted for BMI) but exposure to respirable dust was not associated with BP. No clear associations occurred between welding and endothelial function, or other effect markers. A modest increase in BP was found among welders compared to controls suggesting that low-to-moderate exposure to welding fumes remains a risk factor for cardiovascular disease.

  13. 76 FR 30878 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-27

    ... Eastern Daylight Saving Time on June 20, 2011. ADDRESSES: Comments must be identified with ``RIN 1219-AB64... commenters additional time to review and comment on the proposed rule. DATES: The comment period for the... providing additional time for interested parties to submit comments. MSHA is extending the comment period...

  14. Exposure assessment of lead from food and airborne dusts and biomonitoring in pregnant mothers, their fetus and siblings in Karachi, Pakistan and Shimotsuke, Japan.

    PubMed

    Kayama, Fujio; Fatmi, Zafar; Ikegami, Akihiko; Mizuno, Atsuko; Ohtsu, Mayumi; Mise, Nathern; Cui, Xiaoyi; Ogawa, Masanori; Sakamoto, Takako; Nakagi, Yoshiko; Yoshida, Takahiko; Sahito, Ambreen; Naeem, Shahla; Ghias, Kulsoom; Zuberi, Hina; Tariq, Kanwal; Kobayashi, Yayoi; Nohara, Keiko

    2016-03-01

    Exposure assessment of lead (Pb) and Arsenic (As) from food, water, and house dust intake were assessed among pregnant women, their children and fetuses in Pakistan and Japan, as well as their body burden of the metals in their blood. Fifty families which included a pregnant woman, a fetus and the 1-3-year-old siblings were recruited in Karachi and Khairpur in Pakistan, and Shimotsuke and Asahikawa in Japan, respectively. Their dietary exposure to Pb and As was measured in 3-day food duplicates and drinking water by ICP-MP. Pb in house dust and respirable dust was evaluated with an energy dispersive X-ray fluorescence spectrometry. Non-radioactive isotope Pb profiles of blood specimens will be compared with those of the exposure origins, such as food duplicates, respirable house dust, the soils nearby, and gasoline. Judging from the data collected and analyzed so far, contribution from dietary intake is highly correlated to higher body burden of Pb among Pakistani mothers. Additional data analyses will reveal the status of Pb and As body burden in Pakistani mothers, fetuses and their siblings, and causal sources of high body burden is delineated by Pb isotope profile analysis of different sources of Pb exposure.

  15. An analysis of employee exposure to organic dust at large-scale composting facilities

    NASA Astrophysics Data System (ADS)

    Sykes, P.; Allen, J. A.; Wildsmith, J. D.; Jones, K. P.

    2009-02-01

    The occupational health implications from exposure to dust, endotoxin and 1-3 β Glucan at commercial composting sites are uncertain. This study aims to establish employee exposure levels to inhalable and respirable dust, endotoxin and 1-3 β Glucan during various operational practices in the composting process. Personal samples were collected and the inhalable and respirable dust fractions were determined by gravimetric analysis. Endotoxin concentrations were determined using a Limulus Amebocyte Lysate assay (LAL). 1-3 β Glucan levels were estimated using a specific blocking agent to establish the contribution that these compounds gave to the original endotoxin assay. Employees' exposure to dust was found to be generally lower than the levels stipulated in the Control of Substances Hazardous to Health Regulations (COSHH) 2002 (as amended), (median inhalable fraction 1.08 mg/m3, min 0.25 mg/m3 max 10.80 mg/m3, median respirable fraction 0.05 mg/m3, min 0.02 mg/m3, max 1.49 mg/m3). Determination of the biological component of the dust showed that employees' exposures to endotoxin were elevated (median 31.5 EU/m3, min 2.00 EU/m3, max 1741.78 EU/m3), particularly when waste was agitated (median 175.0 EU/m3, min 2.03 EU/m3, max 1741.78 EU/m3). Eight out of 32 (25%) of the personal exposure data for endotoxin exceeded the 200 EU/m3 temporary legal limit adopted in the Netherlands and thirteen out of 32 (40.6%) exceeded the suggested 50 EU/m3 guidance level suggested to protect workers from respiratory health effects. A significant correlation was observed between employee inhalable dust exposure and personal endotoxin concentration (r = 0.728, p<0.05) and also personal endotoxin exposure and 1-3 β Glucan concentration (r = 0.817, p<0.05). Further work is needed to explore the possibility of using inhalable dust concentration as a predictor for personal endotoxin exposure. The general dust levels stipulated in the COSHH Regulations 2002 (as amended) are inadequate for managing the potential health risks associated with endotoxin exposure at composting sites. Employee exposure levels and dose-response disease mechanisms are not well understood at this present time. Consequently, in light of this uncertainty, it is recommended that a precautionary approach be adopted in managing the potential health risks associated with inhalation of organic dusts at composting sites.

  16. Effect of manual feeding on the level of farmer's exposure to airborne contaminants in the confinement nursery pig house.

    PubMed

    Kim, Ki-Youn; Ko, Han-Jong; Kim, Hyeon-Tae; Kim, Chi-Nyon; Kim, Yoon-Shin; Roh, Young-Man

    2008-04-01

    The objective of the study is to demonstrate an effect of manual feeding on the level of farmer's exposure to airborne contaminants in the confinement nursery pig house. The levels of all the airborne contaminants besides respirable dust, total airborne fungi and ammonia were significantly higher in the treated nursery pig house with feeding than the control nursery pig house without feeding. Although there is no significant difference in respirable dust and total airborne fungi between the treatment and the control, their concentrations in the treated nursery pig house were also higher than the control nursery pig house. The result that the level of ammonia in the treated nursery pig house is lower than the control nursery pig house would be reasoned by the mechanism of ammonia generation in the pig house and adsorption property of ammonia to dust particles. In conclusion, manual feeding by farmer increased the exposure level of airborne contaminants compared to no feeding activity.

  17. Respirable coal dust exposure and respiratory symptoms in South-African coal miners: A comparison of current and ex-miners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Naidoo, R.N.; Robins, T.G.; Seixas, N.

    2006-06-15

    Dose-response associations between respirable dust exposure and respiratory symptoms and between symptoms and spirometry outcomes among currently employed and formerly employed South-African coal miners were investigated. Work histories, interviews, and spirometry and cumulative exposure were assessed among 684 current and 212 ex-miners. Results: Lower prevalences of symptoms were found among employed compared with ex-miners. Associations with increasing exposure for symptoms of phlegm and past history of tuberculosis were observed, whereas other symptom prevalences were higher in the higher exposure categories. Symptomatic ex-miners exhibited lower lung-function compared to the nonsymptomatic. Compared with published data, symptoms rates were low in current minersmore » but high in ex-miners. Although explanations could include the low prevalence of smoking and/or reporting/selection bias, a 'Survivor' and/or a 'hire' effect is more likely, resulting in an underestimation of the dust-related effect.« less

  18. Occupational exposures to respirable crystalline silica during hydraulic fracturing.

    PubMed

    Esswein, Eric J; Breitenstein, Michael; Snawder, John; Kiefer, Max; Sieber, W Karl

    2013-01-01

    This report describes a previously uncharacterized occupational health hazard: work crew exposures to respirable crystalline silica during hydraulic fracturing. Hydraulic fracturing involves high pressure injection of large volumes of water and sand, and smaller quantities of well treatment chemicals, into a gas or oil well to fracture shale or other rock formations, allowing more efficient recovery of hydrocarbons from a petroleum-bearing reservoir. Crystalline silica ("frac sand") is commonly used as a proppant to hold open cracks and fissures created by hydraulic pressure. Each stage of the process requires hundreds of thousands of pounds of quartz-containing sand; millions of pounds may be needed for all zones of a well. Mechanical handling of frac sand creates respirable crystalline silica dust, a potential exposure hazard for workers. Researchers at the National Institute for Occupational Safety and Health collected 111 personal breathing zone samples at 11 sites in five states to evaluate worker exposures to respirable crystalline silica during hydraulic fracturing. At each of the 11 sites, full-shift samples exceeded occupational health criteria (e.g., the Occupational Safety and Health Administration calculated permissible exposure limit, the NIOSH recommended exposure limit, or the ACGIH threshold limit value), in some cases, by 10 or more times the occupational health criteria. Based on these evaluations, an occupational health hazard was determined to exist for workplace exposures to crystalline silica. Seven points of dust generation were identified, including sand handling machinery and dust generated from the work site itself. Recommendations to control exposures include product substitution (when feasible), engineering controls or modifications to sand handling machinery, administrative controls, and use of personal protective equipment. To our knowledge, this represents the first systematic study of work crew exposures to crystalline silica during hydraulic fracturing. Companies that conduct hydraulic fracturing using silica sand should evaluate their operations to determine the potential for worker exposure to respirable crystalline silica and implement controls as necessary to protect workers.

  19. Investigation of coal properties and airborne respirable dust generation. Report of investigations/1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Organiscak, J.A.; Page, S.J.

    1998-10-01

    Laboratory crushing experiments were conducted on a range of low- to high-volatile bituminous coals to investigate the various factors influencing airborne respirable dust (ARD) generation. This research was conducted to identify the principles of ARD liberation from the coal product. Five U.S. bituminous coals were uniformly prepared and processed through a double roll crusher located in a low-velocity wind tunnel. Experimental factors studied included inherent coal seam constituents, coal grindability, specific energy of crushing, product size characteristics, dust cloud electrostatic field, and specific ARD generated. The results of this investigation indicate that a combination of several factors are associated withmore » ARD generation. One factor is the effect of coal rank, described by the inherent moist fuel ratio, on the product size characteristics, defined by Schuhmann size function parameters. Another key factor is the effect of air dry loss (ADL) moisture in the coal seam on the breakage-induced electrostatic field of airborne dust. The effect of these factors is that different percentages of <10-micrometers coal particles are dispersed as ARD. A discussion of electrostatic field principles, coal ADL, and its effect on ARD generation is presented.« less

  20. Emphysema and pulmonary impairment in coal miners: Quantitative relationship with dust exposure and cigarette smoking

    NASA Astrophysics Data System (ADS)

    Kuempel, E. D.; Vallyathan, V.; Green, F. H. Y.

    2009-02-01

    Coal miners have been shown to be at increased risk of developing chronic obstructive pulmonary diseases including emphysema. The objective of this study was to determine whether lifetime cumulative exposure to respirable coal mine dust is a significant predictor of developing emphysema at a clinically-relevant level of severity by the end of life, after controlling for cigarette smoking and other covariates. Clinically-relevant emphysema severity was determined from the association between individuals' lung function during life (forced expiratory volume in one second, FEV1, as a percentage of predicted normal values) and emphysema severity at autopsy (as the proportion of lung tissue affected). In a logistic regression model, cumulative exposure to respirable coal mine dust was a statistically significant predictor of developing clinically-relevant emphysema severity, among both ever-smokers and never-smokers. The odds ratio for developing emphysema associated with FEV1 <80% at the cohort mean cumulative coal dust exposure (87 mg/m3 x yr) was 2.30 (1.46-3.64, 95% confidence limits), and at the cohort mean cigarette smoking (among smokers: 42 pack-years) was 1.95 (1.39-2.79).

  1. Helmet-Cam: tool for assessing miners’ respirable dust exposure

    PubMed Central

    Cecala, A.B.; Reed, W.R.; Joy, G.J.; Westmoreland, S.C.; O’Brien, A.D.

    2015-01-01

    Video technology coupled with datalogging exposure monitors have been used to evaluate worker exposure to different types of contaminants. However, previous application of this technology used a stationary video camera to record the worker’s activity while the worker wore some type of contaminant monitor. These techniques are not applicable to mobile workers in the mining industry because of their need to move around the operation while performing their duties. The Helmet-Cam is a recently developed exposure assessment tool that integrates a person-wearable video recorder with a datalogging dust monitor. These are worn by the miner in a backpack, safety belt or safety vest to identify areas or job tasks of elevated exposure. After a miner performs his or her job while wearing the unit, the video and dust exposure data files are downloaded to a computer and then merged together through a NIOSH-developed computer software program called Enhanced Video Analysis of Dust Exposure (EVADE). By providing synchronized playback of the merged video footage and dust exposure data, the EVADE software allows for the assessment and identification of key work areas and processes, as well as work tasks that significantly impact a worker’s personal respirable dust exposure. The Helmet-Cam technology has been tested at a number of metal/nonmetal mining operations and has proven to be a valuable assessment tool. Mining companies wishing to use this technique can purchase a commercially available video camera and an instantaneous dust monitor to obtain the necessary data, and the NIOSH-developed EVADE software will be available for download at no cost on the NIOSH website. PMID:26380529

  2. Using Dust Assessment Technology to Leverage Mine Site Manager-Worker Communication and Health Behavior: A Longitudinal Case Study

    PubMed Central

    Haas, Emily J.; Cecala, Andrew B.; Hoebbel, Cassandra L.

    2016-01-01

    Research continues to investigate barriers to managing occupational health and safety behaviors among the workforce. Recent literature argues that (1) there is a lack of consistent, multilevel communication and application of health and safety practices, and (2) social scientific methods are absent when determining how to manage injury prevention in the workplace. In response, the current study developed and tested a multilevel intervention case study at two industrial mineral mines to help managers and workers communicate about and reduce respirable silica dust exposures at their mine sites. A dust assessment technology, the Helmet-CAM, was used to identify and encourage communication about potential problem areas and tasks on site that contributed to elevated exposures. The intervention involved pre- and post-assessment field visits, four weeks apart that included multiple forms of data collection from workers and managers. Results revealed that mine management can utilize dust assessment technology as a risk communication tool to prompt and communicate about healthier behaviors with their workforce. Additionally, when workers were debriefed with the Helmet-CAM data through the device software, the dust exposure data can help improve the knowledge and awareness of workers, empowering them to change subtle behaviors that could reduce future elevated exposures to respirable silica dust. This case study demonstrates that incorporating social scientific methods into the application of health and safety management strategies, such as behavioral modification and technology integration, can leverage managers’ communication practices with workers, subsequently improving health and safety behaviors. PMID:26807445

  3. Temporal variation of indoor air quality in an enclosed swine confinement building.

    PubMed

    O'Shaughnessy, P T; Achutan, C; Karsten, A W

    2002-11-01

    Human health hazards can exist in swine confinement buildings due to poor indoor air quality (IAQ). During this study, airborne dust and ammonia concentrations were monitored within a working farrowing facility as indicators of IAQ. The purposes of this study were to assess the temporal variability of the airborne dust and ammonia levels over both a daily and seasonal basis, and to determine the accuracy of real-time sensors relative to actively sampled data. An ammonia sensor, aerosol photometer, indoor relative humidity sensor, and datalogger containing an indoor temperature sensor were mounted on a board 180 cm above the floor in the center of a room in the facility. Sensor readings were taken once every 4 minutes during animal occupancy (3-week intervals). Measurements of total and respirable dust concentrations by standard method, aerosol size distribution, and ammonia concentrations were taken once per week, in addition to temperature and relative humidity measurements using a thermometer and sling psychrometer, respectively. Samples were taken between September 1999 and August 2000. Diurnal variations in airborne dust revealed an inverse relationship with changes in indoor temperature and, by association, changes in airflow rate. Ammonia levels changed despite relatively stable internal temperatures. This change may be related to both changes in flow rates and in volatility rates. As expected, contaminant concentrations increased during the cold weather months, but these differences were not significantly different from other seasons. However, total dust concentrations were very low (geometric mean = 0.8 mg/m3) throughout the year. Likewise, ammonia concentrations averaged only 3.6 ppm in the well-maintained study site.

  4. A Cross-Sectional Study of the Cardiovascular Effects of Welding Fumes

    PubMed Central

    Li, Huiqi; Hedmer, Maria; Kåredal, Monica; Björk, Jonas; Stockfelt, Leo; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-01-01

    Objectives Occupational exposure to particulate air pollution has been associated with an increased risk of cardiovascular disease. However, the risk to welders working today remains unclear. We aimed to elucidate the cardiovascular effects of exposure to welding fumes. Methods In a cross-sectional study, structured interviews and biological sampling were conducted for 101 welders and 127 controls (all non-smoking males) from southern Sweden. Personal breathing zone sampling of respirable dust was performed. Blood pressure (BP) and endothelial function (using peripheral arterial tonometry) were measured. Plasma and serum samples were collected from peripheral blood for measurement of C-reactive protein, low-density lipoprotein, homocysteine, serum amyloid A, and cytokines. Results Welders were exposed to 10-fold higher levels of particles than controls. Welders had significantly higher BP compared to controls, an average of 5 mm Hg higher systolic and diastolic BP (P≤0.001). IL-8 was 3.4 ng/L higher in welders (P=0.010). Years working as a welder were significantly associated with increased BP (β=0.35, 95%CI 0.13 – 0.58, P=0.0024 for systolic BP; β=0.32, 95%CI 0.16 – 0.48, P<0.001 for diastolic BP, adjusted for BMI) but exposure to respirable dust was not associated with BP. No clear associations occurred between welding and endothelial function, or other effect markers. Conclusions A modest increase in BP was found among welders compared to controls suggesting that low-to-moderate exposure to welding fumes remains a risk factor for cardiovascular disease. PMID:26147298

  5. Health-hazard evaluation report HETA 88-104-2207, Asarco-Troy Unit Mine, Troy, Montana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cornwell, R.J.; Knutti, E.B.

    1992-04-01

    In response to a request from the United Mine Workers of America, an investigation was made of possible exposures to diesel exhaust, silica (14808607) and noise at the ASARCO Troy Unit Mine (SIC-1044), Troy, Montana. The silver mine was also a significant copper producer. Approximately 314 persons were employed in two basic operations of mining and ore concentration. The ore was mined by the room and pillar method. Extraction calls for drilling, blasting, scaling and roof bolting, mucking and hauling. Exposures to nitrogen-dioxide (10102440) ranged from 0.16 to 4.61 parts per million (ppm) some of which were in excess ofmore » the recommended NIOSH limit of 1ppm. Coal-tar-pitch volatiles ranged in concentration from 0.11 to 1.67mg/cu m. Exposure to diesel particulates ranged from 0.22 to 3.99mg/cu m with a mean concentration of 1.60mg/cu m. Respirable dust concentrations ranged from 0.26 to 16.74mg/cu m with a mean of 2.24mg/cu m. The mean quartz content of surface dust samples was 24% and of underground samples was 7%. Noise exposures ranged from 65.5 to 103.8 decibels-A for the 8 hour time weighted average samples. The authors conclude that a health hazard existed due to exposures to respirable silica, noise and diesel combustion products. The authors recommend specific measures to reduce the potential hazardous exposures and enhance the company's medical surveillance program.« less

  6. Performance of High-Flow-Rate Samplers for Respirable Crystalline Silica Measurement Under Field Conditions: Preliminary Study.

    PubMed

    Coggins, Marie A; Healy, Catherine B; Lee, Taekhee; Harper, Martin

    2014-01-01

    Restoration stone work regularly involves work with high-silica-content materials (e.g., sandstone), but low-silica-content materials (<2 % quartz) such as limestone and lime mortar are also used. A combination of short sample duration and low silica content makes the quantification of worker exposure to respirable crystalline silica (RCS) difficult. This problem will be further compounded by the introduction of lower occupational exposure standards for RCS. The objective of this work was to determine whether higher-flow samplers might be an effective tool in characterizing lower RCS concentrations. A short study was performed to evaluate the performance of three high-flow samplers (FSP10, CIP10-R, and GK2.69) using side-by-side sampling with low-flow samplers (SIMPEDS and 10-mm nylon cyclones) for RCS exposure measurement at a restoration stonemasonry field site. A total of 19 side-by-side sample replicates for each high-flow and low-flow sampler pair were collected from work tasks involving limestone and sandstone. Most of the RCS (quartz) masses collected with the high-flow-rate samplers were above the limit of detection (62 % to 84 %) relative to the low-flow-rate samplers (58 % to 78 %). The average of the respirable mass concentration ratios for CIP10-R/SIMPEDS, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs and the range of the quartz concentration ratios for the CIP10-R/SIMPEDS, CIP10-R/10-mm nylon, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs included unity with an average close to unity, indicating no likely difference between the reported values for each sampler. Workers reported problems related to the weight of the sampling pumps for the high-flow-rate samplers. Respirable mass concentration data suggest that the high-flow-rate samplers evaluated would be appropriate for sampling respirable dust concentrations during restoration stone work. Results from the comparison of average quartz concentration ratios between high-and low-flow samplers suggest that the higher mass collected by the high-flow-rate samplers did not interfere with the quartz measurement. A sig-nificant portion of the data collected with the high-flow-rate samplers (>82 %) were greater than the limit of detection, which indicates that these samplers are suitable for quantifying exposures, even with low-quartz materials.

  7. 30 CFR 75.330 - Face ventilation control devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... maintaining concentrations of respirable dust, methane, and other harmful gases, in accordance with the levels..., production activities in the working place shall cease until necessary repairs are made and adequate...

  8. 30 CFR 75.330 - Face ventilation control devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... maintaining concentrations of respirable dust, methane, and other harmful gases, in accordance with the levels..., production activities in the working place shall cease until necessary repairs are made and adequate...

  9. 30 CFR 75.330 - Face ventilation control devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... maintaining concentrations of respirable dust, methane, and other harmful gases, in accordance with the levels..., production activities in the working place shall cease until necessary repairs are made and adequate...

  10. 30 CFR 75.330 - Face ventilation control devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maintaining concentrations of respirable dust, methane, and other harmful gases, in accordance with the levels..., production activities in the working place shall cease until necessary repairs are made and adequate...

  11. 30 CFR 75.330 - Face ventilation control devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... maintaining concentrations of respirable dust, methane, and other harmful gases, in accordance with the levels..., production activities in the working place shall cease until necessary repairs are made and adequate...

  12. Pneumoconiosis after sericite inhalation.

    PubMed

    Algranti, E; Handar, A M; Dumortier, P; Mendonça, E M C; Rodrigues, G L; Santos, A M A; Mauad, T; Dolhnikoff, M; De Vuyst, P; Saldiva, P H N; Bussacos, M A

    2005-03-01

    Between 1997 and 1999 three sericite plant workers in Parana, Brazil, were diagnosed with pneumoconiosis. To investigate and describe the radiological, clinical, and pathological changes in miners and millers exposed to sericite dust with mineralogical characteristics of inhaled dust. The working premises were visited to examine the sericite processing and to classify the jobs according to make qualitative evaluation. Respirable dust was collected and the amount of crystalline silica and particle size distribution were measured. Forty four workers were examined by a standard questionnaire for respiratory symptoms, spirometry, and chest x ray. Material from an open lung biopsy was reviewed for histopathological and mineralogical analysis, together with sericite samples from the work site to compare the mineral characteristics in lung lesions and work area. Respirable dust contained 4.5-10.0% crystalline silica. Particle size distribution showed a heavy burden of very fine particles (23-55%) with a mean diameter of <0.5 microm. Mean age of sericite miners was 41.0 (11.9) and mean number of years of exposure was 13.5 (10.1). In 52.3% of workers (23/44), chest radiographs presented a median category of 1/0 or above, and 18.2% (8/44) had a reduced FEV1. There was a significant association between exposure indices and x ray category. Histological studies of the lung biopsy showed lesions compatible with mixed dust fibrosis with no silicotic nodules. x Ray diffraction analysis of the lung dust residue and the bulk samples collected from work area showed similar mineralogical characteristics. Muscovite and kaolinite were the major mineral particle inclusions in the lung. Exposure to fine sericite particles is associated with the development of functional and radiological changes in workers inducing mixed dust lesions, which are distinct histologically from silicosis.

  13. Dust exposure in workers from grain storage facilities in Costa Rica.

    PubMed

    Rodríguez-Zamora, María G; Medina-Escobar, Lourdes; Mora, Glend; Zock, Jan-Paul; van Wendel de Joode, Berna; Mora, Ana M

    2017-08-01

    About 12 million workers are involved in the production of basic grains in Central America. However, few studies in the region have examined the occupational factors associated with inhalable dust exposure. (i) To assess the exposure to inhalable dust in workers from rice, maize, and wheat storage facilities in Costa Rica; (ii) to examine the occupational factors associated with this exposure; and (iii) to measure concentrations of respirable and thoracic particles in different areas of the storage facilities. We measured inhalable (<100μm) dust concentrations in 176 personal samples collected from 136 workers of eight grain storage facilities in Costa Rica. We also measured respirable (<4μm) and thoracic (<10μm) dust particles in several areas of the storage facilities. Geometric mean (GM) and geometric standard deviation (GSD) inhalable dust concentrations were 2.0mg/m 3 and 7.8 (range=<0.2-275.4mg/m 3 ). Personal inhalable dust concentrations were associated with job category [GM for category/GM for administrative staff and other workers (95% CI)=4.4 (2.6, 7.2) for packing; 20.4 (12.3, 34.7) for dehulling; 109.6 (50.1, 234.4) for unloading in flat bed sheds; 24.0 (14.5, 39.8) for unloading in pits; and 31.6 (18.6, 52.5) for drying], and cleaning task [15.8 (95% CI: 10.0, 26.3) in workers who cleaned in addition to their regular tasks]. Higher area concentrations of thoracic dust particles were found in wheat (GM and GSD=4.3mg/m 3 and 4.5) and maize (3.0mg/m 3 and 3.9) storage facilities, and in grain drying (2.3mg/m 3 and 3.1) and unloading (1.5mg/m 3 and 4.8) areas. Operators of grain storage facilities showed elevated inhalable dust concentrations, mostly above international exposure limits. Better engineering and administrative controls are needed. Copyright © 2017 Elsevier GmbH. All rights reserved.

  14. Inhalation Toxicity of Ground Lunar Dust Prepared from Apollo-14 Soil

    NASA Technical Reports Server (NTRS)

    James, John T.; Lam, Chiu-wing; Scully, Robert R.; Cooper, Bonnie L.

    2011-01-01

    Within the decade one or more space-faring nations intend to return humans to the moon for more in depth exploration of the lunar surface and subsurface than was conducted during the Apollo days. The lunar surface is blanketed with fine dust, much of it in the respirable size range (<10 micron). Eventually, there is likely to be a habitable base and rovers available to reach distant targets for sample acquisition. Despite designs that could minimize the entry of dust into habitats and rovers, it is reasonable to expect lunar dust to pollute both as operations progress. Apollo astronauts were exposed briefly to dust at nuisance levels, but stays of up to 6 months on the lunar surface are envisioned. Will repeated episodic exposures to lunar dust present a health hazard to those engaged in lunar exploration? Using rats exposed to lunar dust by nose-only inhalation, we set out to investigate that question.

  15. Risk and Prevention of Aspergillosis

    MedlinePlus

    ... respirators . Avoid activities that involve close contact to soil or dust, such as yard work or gardening. ... areas. Wear gloves when handling materials such as soil, moss, or manure. To reduce the chances of ...

  16. Assessing Worker Exposures during Composite Material and Fiberglass Repair: A Special

    DTIC Science & Technology

    2015-01-01

    zinc, or lead chromate. 3.2.3 Clean Wiping. Removal of dust, dirt, and oil from depainted surfaces. After depainting, residual dust is present on...aspiration and deposition characteristics of the human respiratory tract. The primary size distributions of interest during advanced composite...the respiratory tract, while the respirable mass is that portion of the total aerosol that ends up in the gas -exchange region of the lungs

  17. Dust and gas exposure in tunnel construction work.

    PubMed

    Bakke, B; Stewart, P; Ulvestad, B; Eduard, W

    2001-01-01

    Personal exposures to dust and gases were measured among 189 underground construction workers who were divided into seven occupational groups performing similar tasks in similar working conditions: drill and blast crew; shaft-drilling crew; tunnel-boring machine crew; shotcreting operators; support workers; concrete workers; and electricians. Outdoor tunnel workers were included as a low-exposed reference group. The highest geometric mean (GM) exposures to total dust (6-7 mg/m3) and respirable dust (2-3 mg/m3) were found for the shotcreters, shaft drillers, and tunnel-boring machine workers. Shaft drillers and tunnel-boring machine workers also had the highest GM exposures to respirable alpha-quartz (0.3-0.4 mg/m3), which exceeded the Norwegian occupational exposure limit (OEL) of 0.1 mg/m3. Shaft drillers had the highest exposure to oil mists (GM=1.4 mg/m3), which was generated mainly from pneumatic drilling. For other groups, exposure to oil mist from diesel exhaust and spraying of oil onto concrete forms resulted in exposures of 0.1-0.5 mg/m3. Exposure to nitrogen dioxide was similar across all groups (GM=0.4-0.9 ppm), except for shaft drillers and tunnel-boring machine workers, who had lower exposures. High short-term exposures (>10 ppm), however, occurred when workers were passing through the blasting cloud.

  18. Silica dust and lung cancer in the German stone, quarrying, and ceramics industries: results of a case-control study

    PubMed Central

    Ulm, K; Waschulzik, B; Ehnes, H; Guldner, K; Thomasson, B; Schwebig, A; Nuss, H

    1999-01-01

    BACKGROUND—A work force based case-control study of lung cancer was performed in non-silicotic subjects exposed to crystalline silica to investigate the association between silica dust and lung cancer excluding the influence of silicosis.
METHODS—Two hundred and forty seven patients with lung cancer and 795 control subjects were enrolled, all of whom had been employed in the German stone, quarrying, or ceramics industries. Smoking was used as a matching criterion. Exposure to silica was quantified by measurements, if available, or otherwise by industrial hygienists. Several indices (peak, average and cumulative exposure) were used to analyse the relationship between the level of exposure and risk of lung cancer as odds ratios (OR).
RESULTS—The risk of lung cancer is associated with the year of and age at first exposure to silica, duration of exposure, and latency. All odds ratios were adjusted for these factors. Considering the peak exposure, the OR for workers exposed to high levels (⩾0.15 mg/m3 respirable silica dust which is the current occupational threshold value for Germany) compared with those exposed to low levels (<0.15 mg/m3) was 0.85 (95% CI 0.58 to 1.25). For the time weighted average exposure the OR was 0.91 (95% CI 0.57 to 1.46). The OR for the cumulative exposure was 1.02 (95% CI 0.67 to 1.55). No increase in risk was evident with increasing exposure.
CONCLUSIONS—This study shows no association between exposure to crystalline silica and lung cancer. The exclusion of subjects with silicosis may have led to dilution with respect to the level of exposure and therefore reduced the power to detect a small risk. Alternatively, the risk of getting lung cancer may be restricted to subjects with silicosis and is not directly linked to silica dust.

 PMID:10092697

  19. 75 FR 20546 - Total Inward Leakage Requirements for Respirators

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-20

    ... respiratory protection to intended users against toxic dusts, mists, fumes, fibers, and biological and infectious aerosols (e.g., influenza A (H5N1), Bacillus anthracis, severe acute respiratory syndrome (SARS...

  20. Amplification and dampening of soil respiration by changes in temperature variability

    USGS Publications Warehouse

    Sierra, C.A.; Harmon, M.E.; Thomann, E.; Perakis, S.S.; Loescher, H.W.

    2011-01-01

    Accelerated release of carbon from soils is one of the most important feed backs related to anthropogenically induced climate change. Studies addressing the mechanisms for soil carbon release through organic matter decomposition have focused on the effect of changes in the average temperature, with little attention to changes in temperature vari-ability. Anthropogenic activities are likely to modify both the average state and the variability of the climatic system; therefore, the effects of future warming on decomposition should not only focus on trends in the average temperature, but also variability expressed as a change of the probability distribution of temperature.Using analytical and numerical analyses we tested common relationships between temperature and respiration and found that the variability of temperature plays an important role determining respiration rates of soil organic matter. Changes in temperature variability, without changes in the average temperature, can affect the amount of carbon released through respiration over the long term. Furthermore, simultaneous changes in the average and variance of temperature can either amplify or dampen there release of carbon through soil respiration as climate regimes change. The effects depend on the degree of convexity of the relationship between temperature and respiration and the magnitude of the change in temperature variance. A potential consequence of this effect of variability would be higher respiration in regions where both the mean and variance of temperature are expected to increase, such as in some low latitude regions; and lower amounts of respiration where the average temperature is expected to increase and the variance to decrease, such as in northern high latitudes.

  1. Respiratory dysfunction in swine production facility workers: dose-response relationships of environmental exposures and pulmonary function.

    PubMed

    Donham, K J; Reynolds, S J; Whitten, P; Merchant, J A; Burmeister, L; Popendorf, W J

    1995-03-01

    Human respiratory health hazards for people working in livestock confinement buildings have been recognized since 1974. However, before comprehensive control programs can be implemented, more knowledge is needed of specific hazardous substances present in the air of these buildings, and at what concentrations they are harmful. Therefore, a medical epidemiological and exposure-response study was conducted on 207 swine producers using intensive housing systems (108 farms). Dose-response relationships between pulmonary function and exposures are reported here. Positive correlations were seen between change in pulmonary function over a work period and exposure to total dust, respirable dust, ammonia, respirable endotoxin, and the interactions of age-of-producer and dust exposure and years-of-working-in-the-facility and dust exposure. Relationships between baseline pulmonary function and exposures were not strong and therefore, not pursued in this study. The correlations between exposure and response were stronger after 6 years of exposure. Multiple regression models were used to identify total dust and ammonia as the two primary environmental predictors of pulmonary function decrements over a work period. The regression models were then used to determine exposure concentrations related to pulmonary function decrements suggestive of a health hazard. Total dust concentrations > or = 2.8 mg/m3 were predictive of a work period decrement of > or = 10% in FEV1. Ammonia concentrations of > or = 7.5 ppm were predictive of a > or = 3% work period decrement in FEV1. These predictive concentrations were similar to a previous dose-response study, which suggested 2.5 mg/m3 of total dust and 7 ppm of NH3 were associated with significant work period decrements. Therefore, dust > or = 2.8 mg/m3 and ammonia > or = 7.5 ppm should be considered reasonable evidence for guidelines regarding hazardous exposure concentrations in this work environment.

  2. Evaluations of bit sleeve and twisted-body bit designs for controlling roof bolter dust

    PubMed Central

    Beck, T.W.

    2015-01-01

    Drilling into coal mine roof strata to install roof bolts has the potential to release substantial quantities of respirable dust. Due to the proximity of drill holes to the breathing zone of roof bolting personnel, dust escaping the holes and avoiding capture by the dust collection system pose a potential respiratory health risk. Controls are available to complement the typical dry vacuum collection system and minimize harmful exposures during the initial phase of drilling. This paper examines the use of a bit sleeve in combination with a dust-hog-type bit to improve dust extraction during the critical initial phase of drilling. A twisted-body drill bit is also evaluated to determine the quantity of dust liberated in comparison with the dust-hog-type bit. Based on the results of our laboratory tests, the bit sleeve may reduce dust emissions by one-half during the initial phase of drilling before the drill bit is fully enclosed by the drill hole. Because collaring is responsible for the largest dust liberations, overall dust emission can also be substantially reduced. The use of a twisted-body bit has minimal improvement on dust capture compared with the commonly used dust-hog-type bit. PMID:26257435

  3. Respiratory exposures associated with silicon carbide production: estimation of cumulative exposures for an epidemiological study.

    PubMed Central

    Smith, T J; Hammond, S K; Laidlaw, F; Fine, S

    1984-01-01

    Silicon carbide is produced by heating a mixture of petroleum coke and silica sand to approximately 2000 degrees C in an electric furnace for 36 hours. During heating, large amounts of carbon monoxide are released, sulphur dioxide is produced from residual sulphur in the coke, and hydrocarbon fume is produced by pyrolysis of the coke. Loading and unloading furnaces causes exposures to respirable dust containing crystalline silica, silicon carbide, and hydrocarbons. In the autumn of 1980 extensive measurements were made of personal exposures to air contaminants. Eight hour time weighted exposures to sulphur dioxide ranged from less than 0.1 ppm to 1.5 ppm and respirable participate exposures ranged from 0.01 mg/m3 to 9.0 mg/m3. Geometric mean particulate exposures for jobs ranged from 0.1 mg/m3 to 1.46 mg/m3. The particulate contained varying amounts of alpha-quartz, ranging from less than 1% to 17%, and most quartz exposures were substantially below the threshold limit value of 100 micrograms/m3. Only traces of cristobalite (less than 1%) were found in the particulate. Median exposures to air contaminants in each job were estimated. Since the operations at the plant had been stable over the past 30 years, it was possible to estimate long term exposures of workers to sulphur dioxide, respirable particulate, quartz, total inorganic material, and extractable organic material. Cumulative exposure (average concentration times exposure duration) for each of the air contaminants was estimated for each worker using his job history. There was sufficient independent variability in the sulphur dioxide and respirable particulate cumulative exposures to make an assessment of their independent effects feasible. The theoretical basis for using the cumulative exposure index and its shortcomings for epidemiological applications were presented. PMID:6691927

  4. 30 CFR 71.201 - Sampling; general requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... rain restriction for a normal work shift as defined in § 71.2 (Definitions) for a period not to exceed... frequency of rain; and (2) The operator did not have reasonable opportunity to complete the respirable dust...

  5. 30 CFR 71.201 - Sampling; general requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... rain restriction for a normal work shift as defined in § 71.2 (Definitions) for a period not to exceed... frequency of rain; and (2) The operator did not have reasonable opportunity to complete the respirable dust...

  6. 30 CFR 71.201 - Sampling; general requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rain restriction for a normal work shift as defined in § 71.2 (Definitions) for a period not to exceed... frequency of rain; and (2) The operator did not have reasonable opportunity to complete the respirable dust...

  7. Health hazard evaluation report HETA 84-437-1532, Perry Nuclear Power Plant, Perry, Ohio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moseley, C.L.

    1984-11-01

    Breathing-zone samples were analyzed for iron, zinc, lead, nickel, and chromium fumes, quartz, cristobalite, and respirable particulates during construction of the Perry Nuclear Power facility, Perry, Ohio in August, 1984. The survey was requested by Local 210 of the Pipefitters Union to evaluate exposure of airborne contaminants to construction workers at the facility. All metal fume and respirable particulates were well below the relevant standards. The author notes that NIOSH conducted two previous surveys at the site and the concentrations of all contaminants have decreased since work has progressed at the facility. The quartz overexposure is due to residual constructionmore » dust. Each contractor should assume responsibility for the health and safety of his employees. Break areas should be vacuumed daily. Good housekeeping practices should be maintained in all areas to prevent exposure to quartz dust.« less

  8. Identification of potential hazards associated with new residential construction.

    PubMed

    Methner, M M

    2000-02-01

    There were several advantages and limitations of this observational study. The most important advantage of this study was the opportunity to observe residential construction workers performing their jobs. By observing work practices, valuable information was gathered about specific trades and their potential exposure to various chemical and physical agents. This information will be useful in guiding subsequent exposure assessments. Probably the greatest limitation of this study was the lack of participation by homebuilders. Ideally, observations of construction processes would have been more objective if the study included the participation of more than one homebuilder. Aside from one worker who was observed to wear safety glasses, leather gloves, and a dust mask, virtually no personal protective equipment (PPE) was observed onsite. Often small contractors do not have the financial resources necessary to procure the appropriate PPE and issue these items to the workers. Based on hazard prevalence, professional judgement, and the degree of hazardous product use, potential exposures that warrant quantitative sampling efforts during Phase 2 of this study are: bulldozer/backhoe operators--noise, vibration, diesel exhaust; concrete workers--naphtha, mineral spirits, Portland cement; asphalt workers--petroleum hydrocarbons, asphalt, mineral spirits; plumbers--methylethyl ketone, acetone, tetrahydrofuran, cyclohexanone; drywall finishers--total and respirable dust, hexane, acetone; painters--ethylene glycol, VOCs; masons--dust (during the preparation of mortar); floor preparation technicians--total and respirable dust; and ceramic tile installers--toluene, naphtha, silica (from grout powder).

  9. Respiratory symptoms and farming practices in farmers associated with an acute febrile illness after organic dust exposure.

    PubMed

    Von Essen, S; Fryzek, J; Nowakowski, B; Wampler, M

    1999-11-01

    To conduct a preliminary study of occupational respiratory complaints in farmers who have experienced organic dust toxic syndrome (ODTS) symptoms. Cross-sectional. An agricultural trade show. None. Two hundred ninety-seven people (204 men, 93 women) completed a questionnaire about agricultural practices, respiratory health (including history of febrile episodes while handling grain), and use of respirators. Spirometry was also performed. ODTS symptoms were described by 107 of the people (36%). A strong significant association was found between ODTS and cough or chest tightness after handling grain (odds ratio [OR], 7.5; 95% confidence ratio [CI], 4.2 to 13.5). People who experienced cough or chest tightness after handling grain were more likely to report handling grain sorghum than people who had not experienced cough or chest tightening after handling grain (OR, 2.1; 95% CI, 1.3 to 3.5). The strong association seen between ODTS and frequent use of a respirator while working in grain bins (OR, 3.9; 95% CI, 1.6 to 9.4) may indicate that farmers began using respirators after respiratory symptoms developed. Having a history consistent with ODTS exposure was very common in the farmers surveyed. Farmers who had a history consistent with ODTS were more likely to report cough or chest tightness with handling grain. Exposure to grain sorghum was more likely to be associated with respiratory symptoms than was exposure to other types of grain. There is a need for additional studies to further examine the relationship between ODTS and respiratory symptoms with grain dust exposure in farmers.

  10. Changes in lung function of granite crushers exposed to moderately high silica concentrations: a 12 year follow up.

    PubMed Central

    Malmberg, P; Hedenström, H; Sundblad, B M

    1993-01-01

    45 granite crushers and 45 age and smoking matched referents underwent pulmonary function tests in 1976 and 1988. On average, the granite crushers at follow up had worked for 22 years, were 52 (range 36-78) years old, and had inhaled a cumulated amount of 7 mg of silica in the respirable dust fraction. Between 1976 and 1988 the average concentration of respirable quartz in air was 0.16 mg/m3 (threshold limit value (TLV) = 0.10 mg/m3). In 1988 the granite crushers had somewhat lower forced expiratory flows (forced expiratory volume in one second/vital capacity (FEV1/VC) -4.5% and forced midexpiratory flow FEF50 -15%) compared with the referents and a more uneven ventilation distribution (17% higher slope of phase III in the nitrogen single breath curve). Five smoking granite crushers, but none of the referents, had an FEV1 < 80% of the predicted. During the 12 year interval the granite crushers had--compared with the matched referents--a greater decrease in FEV1 (-4.6%), FEV1/VC (-5.4%), maximal expiratory flow, (-8%) and FEF50 (-14%), and a larger increase in phase III and static compliance (p < 0.02 in all variables). The functional changes suggest the presence of airways obstruction and increased compliance of the lungs. Exposure to silica at concentrations of about twice the present TLV was thus associated with airways obstruction and loss of elastic recoil rather than fibrosis and a restrictive function loss as seen in silicosis. The changes were on average small, but in some tobacco smokers more pronounced changes were found. PMID:8398859

  11. Occupational exposure to airborne fungi among rice mill workers with special reference to aflatoxin producing A. flavus strains.

    PubMed

    Desai, Manisha Rajib; Ghosh, Sandip

    2003-01-01

    A study was undertaken on environmental mycoflora of rice mills situated in Bawla town, Ahmedabad district. The airborne fungal communities were isolated and identified quantitatively by using Andersen-6-stage viable sampler, midget impinger and high volume samplers (Cone and Hexhlet for total and respirable dusts respectively). Of all the isolates, genus Aspergillus was predominant and among the Aspergillus species, A. flavus was the common isolate, irrespective of the method applied for sample collection. Number of isolates recovered from the working place was significantly greater (p < 0.01) compared to control. Total percentage of aflatoxin positive strains of A. flavus was 8 %. These aflatoxin producing strains were identified on various media, such as Czapek agar (Cz) with 0.05 % anisaldehyde, APA and CAM. Surface morphology of aflatoxin positive strains was studied by SEM. Highly significant total and respirable dust concentrations were found in the work place (p < 0.01) whereas in the store, only the total dust concentration was significantly higher (p < 0.05) than the control site. The study indicates that the rice mill workers are occupationally exposed to airborne aflatoxin producing strains of A. flavus. Thus, they require protective mask for their safety.

  12. In vitro effects of coal fly ashes: hydroxyl radical generation, iron release, and DNA damage and toxicity in rat lung epithelial cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van Maanen, J.M.; Borm, P.J.; Knaapen, A

    1999-12-15

    The authors measured iron release, acellular generation of hydroxyl radicals, and oxidative DNA damage and cytotoxicity in rat lung epithelial (RLE) cells by different coal fly ashes (CFA) that contain both quartz and iron. Seven samples of CFA with different particle size and quartz content (up to 14.1%) were tested along with silica (alpha-quartz), ground coal, and coal mine dust (respirable) as positive control particles, and fine TiO{sub 2} (anatase) as a negative control. Five test samples were pulverized fuel ashes (PFA), two samples were coal gasification (SCG) ashes (quartz content {lt} 0.1%), and one sample was a ground coal.more » No marked differences between SCG and PFA fly ashes were observed, and toxicity did not correlate with physicochemical characteristics or effect parameters. Stable surface radicals were only detected in the reference particles silica and coal mine dust, but not in CFA. On the other hand, hydroxyl radical generation by all fly ashes was observed in the presence of hydrogen peroxide. Also a relationship between acellular hydroxyl radical generation and oxidative DNA damage in RLE cells by CFA was observed. The respirable ashes (MAT023, 38, and 41) showed an extensive level of hydroxyl radical generation in comparison to nonrespirable fly ashes and respirable references. This was related to the iron mobilization from these particles. Themechanisms by which CFA and the positive references (silica, coal mine dust) affect rat lung epithelial cells seem to be different, and the data suggest that quartz in CFA does not act the same as quartz in silica or coal mine dust. However, the results indicate an important role for size and iron release in generation and subsequent effects of reactive oxygen species caused by CFA.« less

  13. Pulmonary function, respiratory symptoms, and dust exposures among workers engaged in early manufacturing processes of tea: a cohort study.

    PubMed

    Shieh, Tzong-Shiun; Chung, Jui-Jung; Wang, Chung-Jing; Tsai, Perng-Jy; Kuo, Yau-Chang; Guo, How-Ran

    2012-02-13

    To evaluate pulmonary function and respiratory symptoms in workers engaged in the early manufacturing processes of tea and to identify the associated factors, we conducted a study in a tea production area in Taiwan. We recruited tea workers who engaged in the early manufacturing process in the Mountain Ali area in Taiwan and a comparison group of local office workers who were matched for age, gender, and smoking habits. We performed questionnaire interviews, pulmonary function tests, skin prick tests, and measurement of specific IgE for tea on the participants and assessed tea dust exposures in the tea factories. The 91 participating tea workers had higher prevalence of respiratory symptoms than the comparison group (32 participants). Among tea workers, ball-rolling workers had the highest prevalence of symptoms and the highest exposures of inhalable dusts. At baseline, tea workers had similar pulmonary functions as the comparison group, but compared to the other tea workers ball-rolling workers had a lower ratio of the 1-second forced expiratory volume to forced vital capacity (FEV1/FVC) and a lower maximal mid-expiratory flow rate expressed as% of the predicted value--MMF (%pred). A total of 58 tea workers participated in the on-site investigation and the cross-shift lung function measurements. We found ball-rolling yielded the highest inhalable dust level, panning yielded the highest respirable dust level, and withering yielded the lowest levels of both dusts. Ball-rolling also yielded the highest coarse fraction (defined as inhalable dusts minus respirable dusts), which represented exposures from nose to tracheobronchial tract. During the shift, we observed significant declines in pulmonary function, especially in ball-rolling workers. Multiple regressions showed that age, height, work tasks, coarse fraction, and number of months working in tea manufacturing each year were independent predictors of certain pulmonary function parameters in tea workers. Tea workers engaged in early manufacturing processes of tea have higher prevalence of respiratory symptoms and pulmonary function impairment, which might be related to tea dust exposures, especially the coarse fraction.

  14. Radiographic outcomes among South African coal miners.

    PubMed

    Naidoo, Rajen N; Robins, Thomas G; Solomon, A; White, Neil; Franzblau, Alfred

    2004-10-01

    This study, the first to document the prevalence of pneumoconiosis among a living South African coal mining cohort, describes dose-response relationships between coal workers' pneumoconiosis and respirable dust exposure, and relationships between pneumoconiosis and both lung function deterioration and respiratory symptoms. A total of 684 current miners and 188 ex-miners from three bituminous-coal mines in Mpumalanga, South Africa, was studied. Chest radiographs were read according to the International Labour Organization (ILO) classification by two experienced readers, one an accredited National Institute for Occupational Safety and Health (NIOSH) "B" reader. Interviews were conducted to assess symptoms, work histories (also obtained from company records), smoking, and other risk factors. Spirometry was performed by trained technicians. Cumulative respirable dust exposure (CDE) estimates were constructed from historical company-collected sampling and researcher-collected personal dust measurements. kappa-Statistics compared the radiographic outcomes predicted by the two readers. An average profusion score was used in the analysis for the outcomes of interest. Because of possible confounding by employment status, most analyses were stratified on current and ex-miner status. The overall prevalence of pneumoconiosis was low (2%-4%). The degree of agreement between the two readers for profusion was moderate to high (kappa=0.58). A significant association (P<0.001) and trend (P<0.001) was seen for pneumoconiosis with increasing categories of CDE among current miners only. A significant (P<0.0001) additional 58 mg-years/m3 CDE was seen among those with pneumoconiosis compared to those without. CDE contributed to a statistically significant 0.19% and 0.11% greater decline in the percent predicted 1-second forced expiration volume (FEV1) and forced vital capacity (FVC), respectively, among current miners with pneumoconiosis than among those without. Logistic regression models showed no significant relationships between pneumoconiosis and symptoms. The overall prevalence of pneumoconiosis, although significantly associated with CDE, was low. The presence of pneumoconiosis is associated with meaningful health effects, including deterioration in lung function. Intervention measures that control exposure are indicated, to reduce these functional effects.

  15. Retrospective view of airborne dust levels in workplace of a chrysotile mine in Ural, Russia.

    PubMed

    Kashansky, S V; Domnin, S G; Kochelayev, V A; Monakhov, D D; Kogan, F M

    2001-04-01

    The Bazhenovskoye chrysotile asbestos deposit has been exploited for 115 years. All the technological operations in the quarry are accompanied by the formation of high-dispersion asbestos-containing aerosols. The dust concentrations at the miner's working places for the last 30 years (1970-2000) were at or below the Russian MACs(m.s.) level (4.0 mg/m3). The seasonal precipitation amount in the deposit area causes a rise in dust content in certain periods. The maximum density of asbestos respirable fibres exceeded 2.7 f/cm3. All the identified fibres belonged to chrysotile asbestos, and no amphibole asbestos, such as tremolite asbestos, has been identified. An excessive dust level remains, despite the dust content level decrease, at the work sites of oversized lump drillers and unloaders, and oncopathology heightened risk remains in these occupational groups, as a result.

  16. RESPIRATION AND INTENSITY DEPENDENCE OF PHOTOSYNTHESIS IN CHLORELLA

    PubMed Central

    Brackett, Frederick S.; Olson, Rodney A.; Crickard, Robert G.

    1953-01-01

    1. Respiration changes as a result of illumination. 2. In the absence of glucose or other supply of substrate, respiration decays in the dark showing at least two types—a fast decay in a few minutes and a slow decay lasting hours. 3. Respiratory response to illumination is delayed. 4. Intermittent illumination (in the absence of glucose, etc.) produces a periodic variation in respiration with a delay or phase lag. 5. Periodic variation of respiration may produce a higher average value in the dark than in the light due to the lag and depending upon the period of intermittent illumination. 6. Based upon average respiration values our data confirm the Kok effect. 7. Interpolated values of respiration, however, result in photosynthetic rates which are linearly dependent upon intensity of illumination. 8. Thus the quantum efficiency is found to be independent of intensity, over the wide range of intensities investigated. PMID:13035068

  17. Laboratory evaluation of the CIP 10 personal dust sampler.

    PubMed

    Gero, A; Tomb, T

    1988-06-01

    The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow through the sampler is induced by the third stage, which is a rotating collector cup that contains a fine grade sponge. Laboratory tests were conducted in a dust chamber using aerosols of Arizona road dust, coal dust and silica dust. Aerosol concentrations measured with the CIP 10 were compared to those measured with the coal mine dust personal sampler unit used in the United States. The results of this study showed that aerosol concentrations measured with the CIP 10 were linearly related to those obtained with the coal mine dust personal sampler. The relationship, however, was dependent on preselector configuration and aerosol characteristics. The collection medium allows some small particles (less than 3 microns) to pass through the sampler without being collected. As much as 13% (by weight) of the aerosol that penetrated through the preseparating stages was exhausted from the sampler.

  18. Effects of disinfectant fogging procedure on dust, ammonia concentration, aerobic bacteria and fungal spores in a farrowing-weaning room.

    PubMed

    Costa, Annamaria; Colosio, Claudio; Gusmara, Claudia; Sala, Vittorio; Guarino, Marcella

    2014-01-01

    In the last decades, large-scale swine production has led to intensive rearing systems in which air quality can be easily degraded by aerial contaminants that can pose a health risk to the pigs and farm workers. This study evaluated the effects of fogging disinfectant procedure on productive performance, ammonia and dust concentration, aerobic bacteria and fungal spores spreading in the farrowing-weaning room. This trial was conducted in 2 identical farrowing-weaning rooms of a piggery. In both rooms, 30 pregnant sows were lodged in individual cages. At 75 days of age, the piglets were moved to the fattening room. In the treated room, with the birth of the first suckling-pig, the fogging disinfection with diluted Virkon S was applied once a day in the experimental room per 15 minutes at 11:00. The fogging disinfectant treatment was switched between rooms at the end of the first trial period. Temperature, relative humidity, dust (TSP-RF fractions and number of particles), ammonia concentration and aerial contaminants (enterococci, Micrococcaeae and fungal spores) were monitored in both rooms. Ammonia concentration reduction induced by fogging disinfection was estimated 18%, total suspended particles and the respirable fraction were significantly lower in the experimental room. Fungal spores resulted in a significant reduction by the fogging procedure, together with dust respirable fraction and fine particulate matter abatement. The fogging disinfection procedure improved air quality in the piggery, thereby enhancing workers and animals health.

  19. Vehicle non-exhaust emissions from the tyre-road interface - effect of stud properties, traction sanding and resuspension

    NASA Astrophysics Data System (ADS)

    Kupiainen, Kaarle J.; Pirjola, Liisa

    2011-08-01

    In Northern cities respirable street dust emission levels (PM 10) are especially high during spring. The spring time dust has been observed to cause health effects as well as discomfort among citizens. Major sources of the dust are the abrasion products from the pavement and traction sand aggregates that are formed due to the motion of the tyre. We studied the formation of respirable abrasion particles in the tyre-road interface due to tyre studs and traction sanding by a mobile laboratory vehicle Sniffer. The measurements were preformed on a test track, where the influence of varying stud weight and stud number per tyre on PM 10 emissions was studied. Studded tyres resulted in higher emission levels than studless tyres especially with speeds 50 km h -1 and higher; however, by using light weight studs, which approximately halves the weight of studs, or by reducing the number of studs per tyre to half, the emission levels decreased by approximately half. Additionally measurements were done with and without traction sand coverage on the pavement of a public road. After traction sanding the emission levels were not affected by tyre type but by formation and suspension of traction sand related dust from the road surface. The emissions after traction sanding decreased as a function of time as passing vehicles' motion shifted the sand grains away from the areas with most tyre-road contact.

  20. Respiratory health effects of opencast coalmining: a cross sectional study of current workers.

    PubMed Central

    Love, R G; Miller, B G; Groat, S K; Hagen, S; Cowie, H A; Johnston, P P; Hutchison, P A; Soutar, C A

    1997-01-01

    OBJECTIVE: To identify whether there is evidence of pneumoconiosis and other respiratory health effects associated with exposure to respirable mixed dust and quartz in United Kingdom opencast coalmines. METHODS: A cross sectional study of current workers (1224 men, 25 women) was carried out at nine large and medium sized opencast sites in England, Scotland, and Wales. To characterise a range of occupational groups within the industry, full shift measurements of personal exposures to respirable dust and quartz were taken. Up to three surveys were carried out at each site, covering all four seasons. For the purposes of comparisons with health indices these groups were further condensed into five broad combined occupational groups. Full sized chest radiographs, respiratory symptoms, occupational history questionnaires, and simple spirometry were used to characterise the respiratory health of the workforce. Logistic or multiple regression techniques were used to examine relations between indices of exposure and respiratory health. RESULTS: None of the group geometric mean dust concentrations, based on 626 valid dust samples, exceeded 1 mg.m-3, and 99% of all quartz concentrations were below 0.4 mg.m-3, the current maximum exposure limit. The highest quartz concentrations were experienced by the rock drilling team and drivers of bulldozers (used to move earth and stone from layers of coal). There were clear differences in mean respirable dust and quartz concentrations between occupational groups. These were consistent across the different sites, but depended in part on the day of measurement. The variations between sites were not much greater than between days, suggesting that differences between sites were at least partly explained by differences in conditions at the time of the measurements. The prevalence of radiographic small opacities profusion category > or = 1/0, based on the median of three readings, was 4.4%. Five men had category 2 pneumoconiosis and two men (including one of these five) had progressive massive fibrosis category A. From regression analyses, the relative risk of attaining a profusion of category > or = 0/1 was estimated to be doubled for every 10 years worked in the dustiest, preproduction opencast jobs, after allowing for age, smoking, and site effects. Risk was not associated with time worked in any other occupation within the industry, nor with previous employment in underground mining or other dusty jobs. Symptoms of chronic bronchitis were present in 13% of the men. Frequency of chronic bronchitis was influenced by years worked in dusty jobs outside opencast mining, but not by time spent in occupations within the industry. Asthmatic symptoms were reported by 5% of the workforce, close to the mean frequency found in adult men. No positive associations were found between asthma and occupational exposures. Lung function on average was close to predicted value and showed no relation to time worked in opencast occupations. CONCLUSIONS: Frequency of (mostly mild) chest radiographic abnormalities is associated with working in the dustier, preproduction jobs in the industry. Although some of these mild abnormalities may be non-occupational (due to aging or smoking), the association with exposure indicates a small risk of pneumoconiosis in these men, and the need to monitor and control exposures, particularly in the high risk occupations. PMID:9245948

  1. Gene Expression Profiling in Lung Tissues from Rat Exposed to Lunar Dust Particles

    NASA Technical Reports Server (NTRS)

    Zhang, Ye; Lam, Chiu-Wing; Zalesak, Selina M.; Kidane, Yared H.; Feiveson, Alan H.; Ploutz-Snyder, Robert; Scully, Robert R.; Williams, Kyle; Wu, Honglu; James, John T.

    2014-01-01

    The Moon's surface is covered by a layer of fine, reactive dust. Lunar dust contain about 1-2% of very fine dust (< 3 micron), that is respirable. The habitable area of any lunar landing vehicle and outpost would inevitably be contaminated with lunar dust that could pose a health risk. The purpose of the study is to analyze the dynamics of global gene expression changes in lung tissues from rats exposed to lunar dust particles. F344 rats were exposed for 4 weeks (6h/d; 5d/wk) in nose-only inhalation chambers to concentrations of 0 (control air), 2.1, 6.8, 21, and 61 mg/m(exp 3) of lunar dust. Five rats per group were euthanized 1 day, and 3 months after the last inhalation exposure. The total RNAs were isolated from lung tissues after being lavaged. The Agilent Rat GE v3 microarray was used to profile global gene expression (44K). The genes with significant expression changes are identified and the gene expression data were further analyzed using various statistical tools.

  2. Field and wind tunnel comparison of four aerosol samplers using agricultural dusts.

    PubMed

    Reynolds, Stephen J; Nakatsu, Jason; Tillery, Marvin; Keefe, Thomas; Mehaffy, John; Thorne, Peter S; Donham, Kelley; Nonnenmann, Matthew; Golla, Vijay; O'shaughnessy, Patrick

    2009-08-01

    Occupational lung disease is a significant problem among agricultural workers exposed to organic dusts. Measurements of exposure in agricultural environments in the USA have traditionally been conducted using 37-mm closed-face cassettes (CFCs) and respirable Cyclones. Inhalable aerosol samplers offer significant improvement for dose estimation studies to reduce respiratory disease. The goals of this study were to determine correction factors between the inhalable samplers (IOM and Button) and the CFC and Cyclone for dusts sampled in livestock buildings and to determine whether these factors vary among livestock types. Determination of these correction factors will allow comparison between inhalable measurements and historical measurements. Ten sets of samples were collected in swine, chicken, turkey, and dairy facilities in both Colorado and Iowa. Pairs of each sampling device were attached to the front and back of a rotating mannequin. Laboratory studies using a still-air chamber and a wind tunnel provided information regarding the effect of wind speed on sampler performance. Overall, the IOM had the lowest coefficient of variation (best precision) and was least affected by changes in wind speed. The performance of the Button was negatively impacted in poultry environments where larger (feather) particulates clogged the holes in the initial screen. The CFC/IOM ratios are important for comparisons between newer and older studies. Wind speed and dust type were both important factors affecting ratios. Based on the field studies (Table 6), a ratio of 0.56 is suggested as a conversion factor for the CFC/IOM (average for all environments because of no statistical difference). Suggested conversion factors for the Button/IOM are swine (0.57), chicken (0.80), turkey (0.53), and dairy (0.67). Any attempt to apply a conversion factor between the Cyclone and inhalable samplers is not recommended.

  3. Occupational Exposure to Crystalline Silica Dust in the United States, 1988–2003

    PubMed Central

    Yassin, Abdiaziz; Yebesi, Francis; Tingle, Rex

    2005-01-01

    The purposes of this study were a) to summarize measurements of airborne (respirable) crystalline silica dust exposure levels among U.S. workers, b) to provide an update of the 1990 Stewart and Rice report on airborne silica exposure levels in high-risk industries and occupations with data for the time period 1988–2003, c) to estimate the number of workers potentially exposed to silica in industries that the Occupational Safety and Health Administration (OSHA) inspected for high exposure levels, and d) to conduct time trend analyses on airborne silica dust exposure levels for time-weighted average (TWA) measurements. Compliance inspection data that were taken from the OSHA Integrated Management Information System (IMIS) for 1988–2003 (n = 7,209) were used to measure the airborne crystalline silica dust exposure levels among U.S. workers. A second-order autoregressive model was applied to assess the change in the mean silica exposure measurements over time. The overall geometric mean of silica exposure levels for 8-hr personal TWA samples collected during programmed inspections was 0.077 mg/m3, well above the applicable American Conference of Governmental Industrial Hygienists threshold limit value of 0.05 mg/m3. Surgical appliances supplies industry [Standard Industrial Classification (SIC) 3842] had the lowest geometric mean silica exposure level of 0.017 mg/m3, compared with the highest level, 0.166 mg/m3, for the metal valves and pipe fitting industry (SIC 3494), for an 8-hr TWA measurement. Although a downward trend in the airborne silica exposure levels was observed during 1988–2003, the results showed that 3.6% of the sampled workers were exposed above the OSHA-calculated permissible exposure limit. PMID:15743711

  4. Simulation of air quality and operational cost to ventilate swine farrowing facilities in Midwest U.S. during winter

    PubMed Central

    Park, Jae Hong; Peters, Thomas M.; Altmaier, Ralph; Jones, Samuel M.; Gassman, Richard; Anthony, T. Renée

    2017-01-01

    We have developed a time-dependent simulation model to estimate in-room concentrations of multiple contaminants [ammonia (NH3), carbon dioxide (CO2), carbon monoxide (CO) and dust] as a function of increased ventilation with filtered recirculation for swine farrowing facilities. Energy and mass balance equations were used to simulate the indoor air quality (IAQ) and operational cost for a variety of ventilation conditions over a 3-month winter period for a facility located in the Midwest U.S., using simplified and real-time production parameters, comparing results to field data. A revised model was improved by minimizing the sum of squared errors (SSE) between modeled and measured NH3 and CO2. After optimizing NH3 and CO2, other IAQ results from the simulation were compared to field measurements using linear regression. For NH3, the coefficient of determination (R2) for simulation results and field measurements improved from 0.02 with the original model to 0.37 with the new model. For CO2, the R2 for simulation results and field measurements was 0.49 with the new model. When the makeup air was matched to hallway air CO2 concentrations (1,500 ppm), simulation results showed the smallest SSE. With the new model, the R2 for other contaminants were 0.34 for inhalable dust, 0.36 for respirable dust, and 0.26 for CO. Operation of the air cleaner decreased inhalable dust by 35% and respirable dust concentrations by 33%, while having no effect on NH3, CO2, in agreement with field data, and increasing operational cost by $860 (58%) for the three-month period. PMID:28775911

  5. Mycobacterium tuberculosis transmission rates in a sanatorium: implications for new preventive guidelines.

    PubMed

    Jernigan, J A; Adal, K A; Anglim, A M; Byers, K E; Farr, B M

    1994-12-01

    In 1990, the Centers for Disease Control and Prevention recommended substituting dust-mist particulate respirators for simple isolation masks in acid-fast bacillus isolation rooms, reasoning that air leaks around the simple masks could result in a higher rate of purified protein derivative skin-test conversion. In 1993, a Centers for Disease Control and Prevention draft guideline proposed that high-efficiency particulate air filter respirators be used instead of dust-mist particulate respirators. Epidemiologic data were not available to assess the importance of these changes or their cost-effectiveness. The University of Virginia was affiliated with a tuberculosis hospital from 1979 until 1987. We surveyed physicians who had served as residents in internal medicine during this period regarding purified protein derivative skin-test history. duration of work at the tuberculosis sanatorium, and any history of unprotected exposures to patients with active pulmonary or laryngeal tuberculosis. Patients with active tuberculosis at the sanatorium were isolated in negative-pressure rooms with UV lights. Physicians wore simple isolation masks in these rooms. Responses were received from 83 former resident physicians. Fifty-two physicians had worked on the tuberculosis wards for a total of 420 weeks, with no subsequent skin-test conversions (95% CI 0 to 1 conversion/8 physician-years). These data document a low risk of occupational transmission of Mycobacterium tuberculosis to physicians who wear simple isolation masks in negative-pressure ventilation rooms with UV lights. This low rate predicts that the additional protective efficacy and cost-effectiveness of the more expensive high-efficiency particulate air filter respirators and the respiratory protection program will be low.

  6. Separation of mycotoxin-containing sources in grain dust and determination of their mycotoxin potential.

    PubMed Central

    Palmgren, M S; Lee, L S

    1986-01-01

    Two distinct reservoirs of mycotoxins exist in fungal-infected cereal grains--the fungal spores and the spore-free mycelium-substrate matrix. Many fungal spores are of respirable size and the mycelium-substrate matrix can be pulverized to form particles of respirable size during routine handling of grain. In order to determine the contribution of each source to the level of mycotoxin contamination of dust, we developed techniques to harvest and separate mycelium-substrate matrices from spores of fungi. Conventional quantitative chromatographic analyses of separated materials indicated that aflatoxin from Aspergillus parasiticus, norsolorinic acid from a mutant of A. parasiticus, and secalonic acid D from Penicillium oxalicum were concentrated in the mycelium-substrate matrices and not in the spores. In contrast, spores of Aspergillus niger and Aspergillus fumigatus contained significant concentrations of aurasperone C and fumigaclavine C, respectively; only negligible amounts of the toxins were detected in the mycelium-substrate matrices of these two fungi. PMID:3709472

  7. Persistent Expression Changes of Fibrosis Related Genes in the Lung Tissues of Rats Exposed to Lunar Dust Particles

    NASA Technical Reports Server (NTRS)

    Zhang, Ye; Lam, Chiu-Wing; Scully, Robert R.; Theriot, Corey; Zalesak, Selina; Yeshitla, Samrawit; Williams, Kyle; Wu, Honglu; James, John T.

    2014-01-01

    The Moon's surface is covered by a layer of reactive dust, containing 1-2% of respirable fine dust (< 3 microns). The habitable area of any lunar landing vehicle would inevitably be contaminated with lunar dust that could pose a health risk. The purpose of the study is to evaluate the toxicity of Apollo moon dust in rodents through inhalation to assess the health risk of dust exposures to humans and to identify the mechanisms and potential pathways involved in lunar dust-induced toxicity. Ccl3, Ccl12, Cxcl2, Cxcl5, Itgb8, Tnf, Ldhc, Clec4e, Bmp7, and Smad6, showed persistently significant expression changes in the lung tissue. The expression of several of these genes were dose- and time- dependent, and were significantly correlated with other pathological. Our previous data showed that no pathological changes were detected in low dose groups. However, several genes, primarily produced by lung epithelial, were significantly altered persistently in response to low-dose dust exposure. The data presented in this study, for the first time, explores the molecular mechanisms of lunar dust induced toxicity, contributing not only the risk assessment for future space exploration, but also understandings of the dust-induced toxicity to humans on earth.

  8. Phospholipid lung surfactant and nanoparticle surface toxicity: Lessons from diesel soots and silicate dusts

    NASA Astrophysics Data System (ADS)

    Wallace, William E.; Keane, Michael J.; Murray, David K.; Chisholm, William P.; Maynard, Andrew D.; Ong, Tong-man

    2007-01-01

    Because of their small size, the specific surface areas of nanoparticulate materials (NP), described as particles having at least one dimension smaller than 100 nm, can be large compared with micrometer-sized respirable particles. This high specific surface area or nanostructural surface properties may affect NP toxicity in comparison with micrometer-sized respirable particles of the same overall composition. Respirable particles depositing on the deep lung surfaces of the respiratory bronchioles or alveoli will contact pulmonary surfactants in the surface hypophase. Diesel exhaust ultrafine particles and respirable silicate micrometer-sized insoluble particles can adsorb components of that surfactant onto the particle surfaces, conditioning the particles surfaces and affecting their in vitro expression of cytotoxicity or genotoxicity. Those effects can be particle surface composition-specific. Effects of particle surface conditioning by a primary component of phospholipid pulmonary surfactant, diacyl phosphatidyl choline, are reviewed for in vitro expression of genotoxicity by diesel exhaust particles and of cytotoxicity by respirable quartz and aluminosilicate kaolin clay particles. Those effects suggest methods and cautions for assaying and interpreting NP properties and biological activities.

  9. Examination of water spray airborne coal dust capture with three wetting agents

    PubMed Central

    Organiscak, J.A.

    2015-01-01

    Water spray applications are one of the principal means of controlling airborne respirable dust in coal mines. Since many coals are hydrophobic and not easily wetted by water, wetting agents can be added to the spray water in an effort to improve coal wetting and assist with dust capture. In order to study wetting agent effects on coal dust capture, laboratory experiments were conducted with three wetting agents used by the coal industry on -325 mesh sized Pocahontas No. 3 coal dust. Significant differences in coal dust sink times were observed among the three wetting agents at water mixture concentrations of 0.05%, 0.1% and 0.2%. The best wetting agent as identified by the coal dust sink test was only tested at the lowest 0.05% water mixture concentration and was found to have a negligible effect on spray airborne dust capture. Water spray airborne dust capture results for all three wetting agents tested at a 0.2% water mixture concentration showed that all three wetting agents exhibit similar but small improvements in dust capture efficiency as compared with water. These results indicate that the coal dust sink test may not be a good predictor for the capture of airborne dust. Additional research is needed to examine if the coal dust sink test is a better predictor of wetting agent dust suppression effects during cutting, loading, conveying and dumping of coal products by comparison to airborne dust capture from sprays. PMID:26251565

  10. Lung cancer risk, silica exposure, and silicosis in Chinese mines and pottery factories: the modifying role of other workplace lung carcinogens.

    PubMed

    Cocco, P; Rice, C H; Chen, J Q; McCawley, M A; McLaughlin, J K; Dosemeci, M

    2001-12-01

    Aims of our study were to explore whether and to what extent exposure to other lung carcinogens, or staging and clinical features of silicosis modify or confound the association between silica and lung cancer. We used data from a nested case-control study, conducted in the late 1980s in 29 Chinese mines and potteries (10 tungsten mines, 6 copper and iron mines, 4 tin mines, 8 pottery factories, and 1 clay mine), that included 316 lung cancer cases and 1,356 controls, matched by decade of birth and facility type. The previous analysis of these data presented results by type of mine or factory. In our study, pooling all 29 Chinese work sites, lung cancer risk showed a modest association with silica exposure. Risk did not vary after excluding subjects with silicosis or adjusting the risk estimates by radiological staging of silicosis. Strong correlation among exposures prevented a detailed evaluation of the role of individual exposures. However, lung cancer risk was for the most part absent when concomitant exposure to other workplace lung carcinogens, such as polycyclic aromatic hydrocarbons (PAHs), nickel or radon-daughters, was considered. The cross classification of lung cancer risk by categories of exposure to respirable silica and total respirable dust did not show an independent effect of total respirable dust. Silicosis showed a modest association with lung cancer, which did not vary by severity of radiological staging, or by radiological evidence of disease progression, or by level of silica exposure. However, among silicotic subjects, lung cancer risk was significantly elevated only when exposure to cadmium and PAH had occurred. Our results suggest that, among silica-exposed Chinese workers, numerous occupational and non-occupational risk factors interact in a complex fashion to modify lung cancer risk. Future epidemiological studies on silica and lung cancer should incorporate detailed information on exposure to other workplace lung carcinogens, total respirable dust, and on surface size and age of silica particles to understand whether and to what extent they affect the carcinogenic potential of silica. Copyright 2001 Wiley-Liss, Inc

  11. Response of Respiration of Soybean Leaves Grown at Ambient and Elevated Carbon Dioxide Concentrations to Day-to-day Variation in Light and Temperature under Field Conditions

    PubMed Central

    BUNCE, JAMES A.

    2005-01-01

    • Background and Aims Respiration is an important component of plant carbon balance, but it remains uncertain how respiration will respond to increases in atmospheric carbon dioxide concentration, and there are few measurements of respiration for crop plants grown at elevated [CO2] under field conditions. The hypothesis that respiration of leaves of soybeans grown at elevated [CO2] is increased is tested; and the effects of photosynthesis and acclimation to temperature examined. • Methods Net rates of carbon dioxide exchange were recorded every 10 min, 24 h per day for mature upper canopy leaves of soybeans grown in field plots at the current ambient [CO2] and at ambient plus 350 µmol mol−1 [CO2] in open top chambers. Measurements were made on pairs of leaves from both [CO2] treatments on a total of 16 d during the middle of the growing seasons of two years. • Key Results Elevated [CO2] increased daytime net carbon dioxide fixation rates per unit of leaf area by an average of 48 %, but had no effect on night-time respiration expressed per unit of area, which averaged 53 mmol m−2 d−1 (1·4 µmol m−2 s−1) for both the ambient and elevated [CO2] treatments. Leaf dry mass per unit of area was increased on average by 23 % by elevated [CO2], and respiration per unit of mass was significantly lower at elevated [CO2]. Respiration increased by a factor of 2·5 between 18 and 26 °C average night temperature, for both [CO2] treatments. • Conclusions These results do not support predictions that elevated [CO2] would increase respiration per unit of area by increasing photosynthesis or by increasing leaf mass per unit of area, nor the idea that acclimation of respiration to temperature would be rapid enough to make dark respiration insensitive to variation in temperature between nights. PMID:15781437

  12. 30 CFR 90.207 - Compliance sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Compliance sampling. 90.207 Section 90.207... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.207 Compliance sampling. (a) The operator shall take five valid respirable dust samples for...

  13. 30 CFR 90.208 - Bimonthly sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bimonthly sampling. 90.208 Section 90.208... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.208 Bimonthly sampling. (a) Each operator shall take one valid respirable dust sample for...

  14. 30 CFR 90.207 - Compliance sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compliance sampling. 90.207 Section 90.207... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.207 Compliance sampling. (a) The operator shall take five valid respirable dust samples for...

  15. 30 CFR 90.208 - Bimonthly sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling. 90.208 Section 90.208... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.208 Bimonthly sampling. (a) Each operator shall take one valid respirable dust sample for...

  16. 30 CFR 70.208 - Bimonthly sampling; designated areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling; designated areas. 70.208... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.208 Bimonthly sampling; designated areas. (a) Each operator shall take one valid respirable dust sample from...

  17. 30 CFR 70.208 - Bimonthly sampling; designated areas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bimonthly sampling; designated areas. 70.208... SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.208 Bimonthly sampling; designated areas. (a) Each operator shall take one valid respirable dust sample from...

  18. 30 CFR 70.100 - Respirable dust standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... mine atmosphere during each shift to which each miner in the active workings of each mine is exposed at... sampling device and in terms of an equivalent concentration determined in accordance with § 70.206 (Approved sampling devices; equivalent concentrations). (b) Each operator shall continuously maintain the...

  19. 30 CFR 70.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... operator. 70.209 Section 70.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures... Laboratory, Pittsburgh Safety and Health Technology Center, Cochran Mill Road, Building 38, P.O. Box 18179...

  20. 30 CFR 70.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... operator. 70.209 Section 70.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures... Laboratory, Pittsburgh Safety and Health Technology Center, Cochran Mill Road, Building 38, P.O. Box 18179...

  1. 30 CFR 70.209 - Respirable dust samples; transmission by operator.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... operator. 70.209 Section 70.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures... Laboratory, Pittsburgh Safety and Health Technology Center, Cochran Mill Road, Building 38, P.O. Box 18179...

  2. METHOD INDUCED EXPOSURE MISCLASSIFICATION FOR A RESPIRABLE DUST SAMPLED USING ISO/ACGIH/CEN CRITERIA. (R826786)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  3. 30 CFR 70.220 - Status change reports.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.220 Status change reports. (a) If there is a change in operational status that affects the respirable dust sampling requirements of this...

  4. True Measures

    ERIC Educational Resources Information Center

    Cox, Ron

    2010-01-01

    Air filters perform an important function in commercial and institutional facilities. Because indoor air typically is two to five times more polluted than outdoor air, air filters are needed to remove respirable particles such as microorganisms, dust and allergens from the breathing air. In fact, air filters provide the primary defense for…

  5. 30 CFR 70.207 - Bimonthly sampling; mechanized mining units.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling; mechanized mining units. 70... Bimonthly sampling; mechanized mining units. (a) Each operator shall take five valid respirable dust samples from the designated occupation in each mechanized mining unit during each bimonthly period beginning...

  6. Elemental properties of coal slag and measured airborne exposures at two coal slag processing facilities

    PubMed Central

    Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L

    2017-01-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; b) full-shift area air samples for dust, metals, and crystalline silica; and c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43–0.48% (4,300–4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2–38 mg/m3) and bag house (21 mg/m3) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1–6.6 mg/m3 total; and 0.1–0.4 mg/m3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities. PMID:27808662

  7. Elemental properties of coal slag and measured airborne exposures at two coal slag processing facilities.

    PubMed

    Mugford, Christopher; Boylstein, Randy; Gibbs, Jenna L

    2017-05-01

    In 1974, the National Institute for Occupational Safety and Health recommended a ban on the use of silica sand abrasives containing >1% silica due to the risk of silicosis. This gave rise to substitutes including coal slag. An Occupational Safety and Health Administration investigation in 2010 uncovered a case cluster of suspected pneumoconiosis in four former workers at a coal slag processing facility in Illinois, possibly attributable to occupational exposure to coal slag dust. This article presents the results from a National Institute for Occupational Safety and Health industrial hygiene survey at the same coal slag processing facility and a second facility. The industrial hygiene survey consisted of the collection of: (a) bulk samples of unprocessed coal slag, finished granule product, and settled dust for metals and silica; (b) full-shift area air samples for dust, metals, and crystalline silica; and (c) full-shift personal air samples for dust, metals, and crystalline silica. Bulk samples consisted mainly of iron, manganese, titanium, and vanadium. Some samples had detectable levels of arsenic, beryllium, cadmium, and cobalt. Unprocessed coal slags from Illinois and Kentucky contained 0.43-0.48% (4,300-4,800 mg/kg) silica. Full-shift area air samples identified elevated total dust levels in the screen (2-38 mg/m 3 ) and bag house (21 mg/m 3 ) areas. Full-shift area air samples identified beryllium, chromium, cobalt, copper, iron, nickel, manganese, and vanadium. Overall, personal air samples for total and respirable dust (0.1-6.6 mg/m 3 total; and 0.1-0.4 mg/m 3 respirable) were lower than area air samples. All full-shift personal air samples for metals and silica were below published occupational exposure limits. All bulk samples of finished product granules contained less than 1% silica, supporting the claim coal slag may present less risk for silicosis than silica sand. We note that the results presented here are solely from two coal slag processing facilities, and more in-depth air monitoring is needed to better characterize occupational exposure to coal slag dust, metals, and silica at similar facilities.

  8. Dust control by air-blocking shelves and dust collector-to-bailing airflow ratios for a surface mine drill shroud

    PubMed Central

    Zheng, Y.; Reed, W.R.; Potts, J.D.; Li, M.; Rider, J.P.

    2018-01-01

    The National Institute for Occupational Safety and Health (NIOSH) recently developed a series of validated models utilizing computational fluid dynamics (CFD) to study the effects of air-blocking shelves on airflows and respirable dust distribution associated with medium-sized surface blasthole drill shrouds as part of a dry dust collector system. Using validated CFD models, three different air-blocking shelves were included in the present study: a 15.2-cm (6-in.)-wide shelf; a 7.6-cm (3-in.)-wide shelf; and a 7.6-cm (3-in.)-wide shelf at four different shelf heights. In addition, the dust-collector-to-bailing airflow ratios of 1.75:1, 1.5:1, 1.25:1 and 1:1 were evaluated for the 15.2-cm (6-in.)-wide air-blocking shelf. This paper describes the methodology used to develop the CFD models. The effects of air-blocking shelves and dust collector-to-bailing airflow ratios were identified by the study, and problem regions were revealed under certain conditions.

  9. 30 CFR 70.202 - Certified person; sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certified person; sampling. 70.202 Section 70... HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.202 Certified person; sampling. (a) The respirable dust sampling required by this part shall be done by a certified person. (b...

  10. 30 CFR 70.201 - Sampling; general requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Sampling; general requirements. 70.201 Section... AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.201 Sampling... respirable dust in the active workings of the mine as required by this part with a sampling device approved...

  11. 30 CFR 70.202 - Certified person; sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certified person; sampling. 70.202 Section 70... HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.202 Certified person; sampling. (a) The respirable dust sampling required by this part shall be done by a certified person. (b...

  12. 30 CFR 70.201 - Sampling; general requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Sampling; general requirements. 70.201 Section... AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.201 Sampling... respirable dust in the active workings of the mine as required by this part with a sampling device approved...

  13. Generation rate and particle size distribution of wood dust by handheld sanding operation.

    PubMed

    Ojima, Jun

    2016-11-29

    The International Agency for Research on Cancer (IARC) and Japan Society for Occupational Health (JSOH) classified wood dust as a human carcinogen. Former studies have suggested that sanding with a portable sander is one of the processes that are liable to cause highest exposure to wood dust. However, the wood dust by sanding operation has not been investigated sufficiently. In this study, the generation rate and the particle size distribution of the wood dust produced by handheld sanding operation were observed by laboratory experiments. Beech and cypress were taken as typical hard and soft wood specimen respectively, and sanded with a portable sander. Three grades of sand paper (coarse, medium, fine) were attached to the sander in turn to be tested. The quantity of the wood dust produced by the sander was measured by weighing the specimen before and after the sanding and then the generation rate of the dust was calculated. Soft wood generated more dust than hard wood due to the difference in abrasion durability. A coarse sand paper produced more dust than a fine sand paper. The particles of less than 1 μm diameter were scarcely observed in the wood dust. When the specimens were sanded with a fine sand paper, the mass median aerodynamic diameters of beech dust and cypress dust were 9.0 μm and 9.8 μm, respectively. Respirable wood dust is able to be controlled by general ventilation with more than 0.7-4.2 m 3 /min ventilation rate.

  14. Debilitating lung disease among surface coal miners with no underground mining tenure.

    PubMed

    Halldin, Cara N; Reed, William R; Joy, Gerald J; Colinet, Jay F; Rider, James P; Petsonk, Edward L; Abraham, Jerrold L; Wolfe, Anita L; Storey, Eileen; Laney, A Scott

    2015-01-01

    To characterize exposure histories and respiratory disease among surface coal miners identified with progressive massive fibrosis from a 2010 to 2011 pneumoconiosis survey. Job history, tenure, and radiograph interpretations were verified. Previous radiographs were reviewed when available. Telephone follow-up sought additional work and medical history information. Among eight miners who worked as drill operators or blasters for most of their tenure (median, 35.5 years), two reported poor dust control practices, working in visible dust clouds as recently as 2012. Chest radiographs progressed to progressive massive fibrosis in as few as 11 years. One miner's lung biopsy demonstrated fibrosis and interstitial accumulation of macrophages containing abundant silica, aluminum silicate, and titanium dust particles. Overexposure to respirable silica resulted in progressive massive fibrosis among current surface coal miners with no underground mining tenure. Inadequate dust control during drilling/blasting is likely an important etiologic factor.

  15. Debilitating Lung Disease Among Surface Coal Miners With No Underground Mining Tenure

    PubMed Central

    Halldin, Cara N.; Reed, William R.; Joy, Gerald J.; Colinet, Jay F.; Rider, James P.; Petsonk, Edward L.; Abraham, Jerrold L.; Wolfe, Anita L.; Storey, Eileen; Laney, A. Scott

    2015-01-01

    Objective To characterize exposure histories and respiratory disease among surface coal miners identified with progressive massive fibrosis from a 2010 to 2011 pneumoconiosis survey. Methods Job history, tenure, and radiograph interpretations were verified. Previous radiographs were reviewed when available. Telephone follow-up sought additional work and medical history information. Results Among eight miners who worked as drill operators or blasters for most of their tenure (median, 35.5 years), two reported poor dust control practices, working in visible dust clouds as recently as 2012. Chest radiographs progressed to progressive massive fibrosis in as few as 11 years. One miner’s lung biopsy demonstrated fibrosis and interstitial accumulation of macrophages containing abundant silica, aluminum silicate, and titanium dust particles. Conclusions Overexposure to respirable silica resulted in progressive massive fibrosis among current surface coal miners with no underground mining tenure. Inadequate dust control during drilling/blasting is likely an important etiologic factor. PMID:25563541

  16. Determination of crystalline silica in respirable dust upon occupational exposure for Egyptian workers

    PubMed Central

    MOHAMED, Sabrein H.; EL-ANSARY, Aida L.; EL-AZIZ, Eman M. Abd

    2017-01-01

    Crystalline free silica is considered as a lung carcinogen and the occupational exposure to its dust is a health hazard to workers employed in industries that involve ores of mineral dust. In Egypt, thousands of people work under conditions of silica dust exposure exceeding the occupational exposure limit, as a result the monitoring of this occupational exposure to crystalline silica dust is required by government legislation. The assessment of the later is a multi-phase process, depend on workplace measurements, quantitative analyses of samples, and comparison of results with the permissible limits. This study aims to investigate occupational exposure to crystalline silica dust at 22 factories in Egypt with different industrial activities like stone cutting, glass making, ceramic, and sand blasting. Dust samples were collected from work sites at the breathing zone using a personal sampling pump and a size-selective cyclone and analyzed using FTIR. The sampling period was 60–120 min. The results show that the exposure at each of the industrial sectors is very much higher than the current national and international limits, and that lead to a great risk of lung cancer and mortality to workers. PMID:29199263

  17. Toxicity of Lunar Dust in Lungs Assessed by Examining Biomarkers in Exposed Mice

    NASA Technical Reports Server (NTRS)

    Lam, C.-W.; James, J. T.; Zeidler-Erdely, P. C.; Castranova, V.; Young, S. H.; Quan, C. L.; Khan-Mayberry, N.; Taylor, L. A.

    2010-01-01

    NASA is contemplating to build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of soil, of which the finest portion is highly reactive dust. Dust samples of respirable sizes were aerodynamically isolated from two lunar soil samples of different maturities (cosmic exposure ages) collected during the Apollo 16 mission. The lunar dust samples, TiO2, or quartz, suspended in normal saline were given to groups of 5 C57 male mice by intrapharyngeal aspiration at 0. 1, 0.3, or 1.0 mg/mouse. Because lunar dust aggregates rapidly in aqueous media, some tests were conducted with dusts suspended in Survanta/saline (1:1). The mice were euthanized 7 or 30 days later, and their lungs were lavaged to assess the presence of toxicity biomarkers in bronchioalveolar lavage fluids. The overall results showed that the two lunar dust samples were similar in toxicity, they were more toxic than T102 , but less toxic than quartz. This preliminary study is a part of the large study to obtain data for setting exposure limits for astronauts living on the Moon

  18. Exposure to respirable dust and manganese and prevalence of airways symptoms, among Swedish mild steel welders in the manufacturing industry.

    PubMed

    Hedmer, Maria; Karlsson, Jan-Eric; Andersson, Ulla; Jacobsson, Helene; Nielsen, Jörn; Tinnerberg, Håkan

    2014-08-01

    Welding fume consists of metal fumes, e.g., manganese (Mn) and gases, e.g., ozone. Particles in the respirable dust (RD) size range dominate. Exposure to welding fume could cause short- and long-term respiratory effects. The prevalence of work-related symptoms among mild steel welders was studied, and the occupational exposure to welding fumes was quantified by repeated measurements of RD, respirable Mn, and ozone. Also the variance components were studied. A questionnaire concerning airway symptoms and occupational history was answered by 79% of a cohort of 484 welders. A group of welders (N = 108) were selected and surveyed by personal exposure measurements of RD and ozone three times during 1 year. The welders had a high frequency of work-related symptoms, e.g., stuffy nose (33%), ocular symptoms (28%), and dry cough (24%). The geometric mean exposure to RD and respirable Mn was 1.3 mg/m(3) (min-max 0.1-38.3 mg/m(3)) and 0.08 mg/m(3) (min-max <0.01-2.13 mg/m(3)), respectively. More than 50% of the Mn concentrations exceeded the Swedish occupational exposure limit (OEL). Mainly, low concentrations of ozone were measured, but 2% of the samples exceeded the OEL. Of the total variance for RD, 30 and 33% can be attributed to within-worker variability and between-company variability, respectively. Welders had a high prevalence of work-related symptom from the airways and eyes. The welders' exposure to Mn was unacceptably high. To reduce the exposure further, control measures in the welding workshops are needed. Correct use of general mechanical ventilation and local exhaust ventilation can, for example, efficiently reduce the exposure.

  19. Lunar Airborne Dust Toxicity Hazard Assessments (Invited)

    NASA Astrophysics Data System (ADS)

    Cooper, B. L.; McKay, D. S.; Taylor, L. A.; Wallace, W. T.; James, J.; Riofrio, L.; Gonzalez, C. P.

    2009-12-01

    The Lunar Airborne Dust Toxicity Assessment Group (LADTAG) is developing data to set the permissible limits for human exposure to lunar dust. This standard will guide the design of airlocks and ports for EVA, as well as the requirements for filtering and monitoring the atmosphere in habitable vehicles, rovers and other modules. LADTAG’s recommendation for permissible exposure limits will be delivered to the Constellation Program in late 2010. The current worst-case exposure limit of 0.05 mg/m3, estimated by LADTAG in 2006, reflects the concern that lunar dust may be as toxic as quartz dust. Freshly-ground quartz is known to be more toxic than un-ground quartz dust. Our research has shown that the surfaces of lunar soil grains can be more readily activated by grinding than quartz. Activation was measured by the amount of free radicals generated—activated simulants generate Reactive Oxygen Species (ROS) i.e., production of hydroxyl free radicals. Of the various influences in the lunar environment, micrometeorite bombardment probably creates the most long-lasting reactivity on the surfaces of grains, although solar wind impingement and short-wavelength UV radiation also contribute. The comminution process creates fractured surfaces with unsatisfied bonds. When these grains are inhaled and carried into the lungs, they will react with lung surfactant and cells, potentially causing tissue damage and disease. Tests on lunar simulants have shown that dissolution and leaching of metals can occur when the grains are exposed to water—the primary component of lung fluid. However, simulants may behave differently than actual lunar soils. Rodent toxicity testing will be done using the respirable fraction of actual lunar soils (particles with physical size of less than 2.5 micrometers). We are currently separating the fine material from the coarser material that comprises >95% of the mass of each soil sample. Dry sieving is not practical in this size range, so a new system was developed for this task. The dust separation system includes a fluidized bed, an elutriation flask, and a cyclone. The product dust is collected on a membrane filter with 0.45 micrometer pore size. Collection and separation efficiencies, and particle size distribution measurements of the material retained in the various components are tracked as development and tests proceed. Calculations show that respirable-sized particles, if released in a habitat, would remain suspended in the air for extended periods of time. Without active dust control, most of this fine dust would end up in the crew’s lungs. Dust exposure standards, similar to those established for quartz on Earth, will determine the design, mass, power, and cost of dust control systems incorporated into lunar habitats and pressurized rovers.

  20. Halogenated flame-retardant concentrations in settled dust, respirable and inhalable particulates and polyurethane foam at gymnastic training facilities and residences.

    PubMed

    La Guardia, Mark J; Hale, Robert C

    2015-06-01

    Halogenated flame-retardants (FRs) are used in a wide array of polymer-containing products. Animal studies and structure-activity modeling exercises suggest that FR exposure may result in detrimental toxicological effects. Workers with extended contact with such polymers (e.g., electronic dismantlers, carpet installers and aircraft personnel) have previously been observed to exhibit elevated body burdens of FRs, e.g., polybrominated diphenyl ethers (PBDEs). Recently, elevated PBDE blood levels were also reported in a non-occupational exposure group, gymnasts. These levels were hypothesized to be related to the large volumes of FR-treated polyurethane foam in gymnastics facilities. To further our understanding of workers' potential exposure, we analyzed FR concentrations in indoor dust and size-fractionated air particulates (respirable (<4 μm) and inhalable (>4 μm)) from gymnastic studios. Values were compared to samples from the homes of coaches employed at these facilities. Polyurethane foam blocks (i.e., pit foam) were also analyzed to characterize potential FR sources. FRs examined included those used to flame-retard polyurethane foam: 8 PBDE congeners, two brominated components of Firemaster 550 (2-ethylhexyl 2, 3, 4, 5-tetrabromobenzoate (TBB) and bis(2-ethylhexyl) 3, 4, 5, 6-tetrabromophthalate (TBPH)) and three chlorinated organophosphates (tris(2-chloroethyl) phosphate (TCEP), tris(1-chloro-2-propyl) phosphate (TCPP) and tris(1,3-dichloro-2-propyl) phosphate (TDCPP)). Several additional FRs not used in polyurethane were also evaluated. These have also been detected in indoor dust and air and may also lead to adverse health effects. These include: BDE-183 and its replacement product (1, 2-bis(2, 4, 6-tribromophenoxy) ethane (BTBPE), two congeners of the deca-BDE formulation (BDE-206, -209) and their replacement decabromodiphenyl ethane (DBDPE) and hexabromocyclododecane (α-, β-, γ-HBCD), and tetrabromobisphenol-A (TBBPA)). Pit foam contained multiple FRs at cumulative concentrations of 12,100 to 25,800 μg g(-1), or 1.2% to 2.6% by weight. TBB and TBPH were the most abundant FRs detected, followed by TDCPP and several PBDEs. The mean total FR burden detected at the gyms was 8.6-fold higher (574 μg g(-1)) than that observed in the house dust samples (66.8 μg g(-1)). However, the polyurethane additives TBB and TDCPP were the only FRs that exhibited significantly greater levels (P<0.05) in gym than house dust. Mean levels of five FRs (BDE-99, -100, -153, -209 and TDCPP) were also higher in respirable particulates from the gyms than the homes and four FRs (BDE-47, TBB, TBPH and DBDPE) were higher at the homes than the gyms; these differences were not significant (P>0.05). Several additional FRs were detected in inhalable particulates; mean levels of BDE-66, -206 and TCPP were higher in the homes and BDE-47, -85, -99, -100, -153, -209, TBB, TBPH, and TDCPP were higher at the gyms. But, only the polyurethane additives i.e., BDE-100, TBB and TDCPP were significantly greater (P<0.05) in inhalable particulates from the gyms than at the homes. In conclusion, polyurethane foam collected from gymnastic studios exhibited a variety of FR compositional signatures; likely reflective of changes in FR usage over time and by different manufacturers. FR concentrations and compositional signatures also differed between settled dust, respirable and inhalable particulates between the gyms and homes. Concentrations of FRs used in polyurethane foam were higher in gym air and dust compared to homes, particularly TBB and TDCPP - which were also the primary FRs detected in the pit foam samples. Although these results should be interpreted with caution, as the sample size was small, these findings do suggest that FR concentrations observed in dust and air particulates from the gymnastic studios are further evidence that individuals frequenting these environments are at greater risk for exposure to these polymer additives. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Signaling Pathways Involved in Lunar Dust Induced Cytotoxicity

    NASA Technical Reports Server (NTRS)

    Zhang, Ye; Lam, Chiu-Wing; Scully, Robert R.; Williams, Kyle; Zalesak, Selina; Wu, Honglu; James, John T.

    2014-01-01

    The Moon's surface is covered by a layer of fine, reactive dust. Lunar dust contain about 1-2% of very fine dust (< 3 micron), that is respirable. The habitable area of any lunar landing vehicle and outpost would inevitably be contaminated with lunar dust that could pose a health risk. The purpose of the study is to evaluate the toxicity of Apollo moon dust in rodents to assess the health risk of dust exposures to humans. One of the particular interests in the study is to evaluate dust-induced changes of the expression of fibrosis-related genes, and to identify specific signaling pathways involved in lunar dust-induced toxicity. F344 rats were exposed for 4 weeks (6h/d; 5d/wk) in nose-only inhalation chambers to concentrations of 0 (control air), 2.1, 6.1, 21, and 61 mg/m(exp 3) of lunar dust. Five rats per group were euthanized 1 day, 1 week, 1 month, and 3 months after the last inhalation exposure. The total RNAs were isolated from the blood or lung tissue after being lavaged, using the Qigen RNeasy kit. The Rat Fibrosis RT2 Profile PCR Array was used to profile the expression of 84 genes relevant to fibrosis. The genes with significant expression changes are identified and the gene expression data were further analyzed using IPA pathway analysis tool to determine the signaling pathways with significant changes.

  2. Altered immune responses in broiler chicken husbandry workers and their association with endotoxin exposure

    PubMed Central

    GAUTAM, Ravi; HEO, Yong; LIM, GyeongDong; SONG, EunSeob; ROQUE, Katharine; LEE, JaeHee; KIM, YeonGyeong; CHO, AhRang; SHIN, SoJung; KIM, ChangYul; BANG, GiHwan; BAHNG, JiYun; KIM, HyoungAh

    2017-01-01

    Exposure to bioaerosols in indoor animal farms associates with respiratory illnesses, but little is known about the immune modulation to chicken farmers. This study aimed to compare the general immunity of chicken farmers with those of control subjects with non-agricultural jobs. Blood taken from the farmers and controls was subjected to plasma IgE and IgG subclass measurements. Isolated peripheral blood mononuclear cells (PBMC) were stimulated and cytokine production was measured. Indoor total and respirable dust levels and their endotoxin (LPS) and aflatoxin (AF) levels in the farms were measured. In total, 29 chicken farmers on 19 farms and 14 age- and sex-matched office workers participated. Hematological differences were not observed. The farmers tended to have higher serum IgE and IgG subclass levels with significance for IgG1. The cytokines released by PBMC from farmers indicated skewing toward Type-2 helper T-cell responses: interferon (IFN)-γ:interleukin (IL)-4 and IFNγ:IL-13 ratios were significantly lower than for control PBMC. The farms had 707.1 EU/m3 LPS in total dust, and 15.8 EU/m3 LPS in respirable dust. Farmers exhibited immune skewing towards allergic immune responses that correlated with the LPS levels on their farms. Chicken farmers may be at risk of respiratory allergies due to occupational endotoxin exposure. PMID:28835578

  3. EVALUATION OF THE PULMONARY TOXICITY OF AMBIENT PARTICULATE MATTER FROM CAMP VICTORY, IRAQ

    PubMed Central

    Porter, K. L.; Green, F. H. Y.; Harley, R. A.; Vallyathan, V.; Castranova, V.; Waldron, N. R.; Leonard, S. S.; Nelson, D. E.; Lewis, J. A.; Jackson, D. A.

    2016-01-01

    Anecdotal reports in the press and epidemiological studies suggest that deployment to Iraq and Afghanistan may be associated with respiratory diseases and symptoms in U.S. military personnel and veterans. Exposures during military operations were complex, but virtually all service members were exposed to high levels of respirable, geogenic dust. Inhalation of other dusts has been shown to be associated with adverse health effects, but the pulmonary toxicity of ambient dust from Iraq has not been previously studied. The relative toxicity of Camp Victory dust was evaluated by comparing it to particulate matter from northern Kuwait, a standard U.S. urban dust, and crystalline silica using a single intratracheal instillation in rats. Lung histology, protein levels, and cell counts were evaluated in the bronchoalveolar lavage fluid 1–150 d later. The Iraq dust provoked an early significant, acute inflammatory response. However, the level of inflammation in response to the Iraq dust, U.S. urban dust, and Kuwait dust rapidly declined and was nearly at control levels by the end of the study At later times, animals exposed to the Iraq, U.S. urban, or Kuwait dusts showed increased small airway remodeling and emphysema compared to silica-exposed and control animals without evidence of fibrosis or premalignant changes. The severity and persistence of pulmonary toxicity of these three dusts from the Middle East resemble those of a U.S. urban dust and are less than those of silica. Therefore, Iraq dust exposure is not highly toxic, but similar to other poorly soluble low-toxicity dusts. PMID:26594896

  4. Aerosol Emission Monitoring and Assessment of Potential Exposure to Multi-walled Carbon Nanotubes in the Manufacture of Polymer Nanocomposites

    PubMed Central

    Thompson, Drew; Chen, Sheng-Chieh; Wang, Jing; Pui, David Y.H.

    2015-01-01

    Recent animal studies have shown that carbon nanotubes (CNTs) may pose a significant health risk to those exposed in the workplace. To further understand this potential risk, effort must be taken to measure the occupational exposure to CNTs. Results from an assessment of potential exposure to multi-walled carbon nanotubes (MWCNTs) conducted at an industrial facility where polymer nanocomposites were manufactured by an extrusion process are presented. Exposure to MWCNTs was quantified by the thermal-optical analysis for elemental carbon (EC) of respirable dust collected by personal sampling. All personal respirable samples collected (n = 8) had estimated 8-h time weighted average (TWA) EC concentrations below the limit of detection for the analysis which was about one-half of the recommended exposure limit for CNTs, 1 µg EC/m3 as an 8-h TWA respirable mass concentration. Potential exposure sources were identified and characterized by direct-reading instruments and area sampling. Area samples analyzed for EC yielded quantifiable mass concentrations inside an enclosure where unbound MWCNTs were handled and near a pelletizer where nanocomposite was cut, while those analyzed by electron microscopy detected the presence of MWCNTs at six locations throughout the facility. Through size selective area sampling it was identified that the airborne MWCNTs present in the workplace were in the form of large agglomerates. This was confirmed by electron microscopy where most of the MWCNT structures observed were in the form of micrometer-sized ropey agglomerates. However, a small fraction of single, free MWCNTs was also observed. It was found that the high number concentrations of nanoparticles, ~200000 particles/cm3, present in the manufacturing facility were likely attributable to polymer fumes produced in the extrusion process. PMID:26209597

  5. Exposure Assessment of a High-energy Tensile Test With Large Carbon Fiber Reinforced Polymer Cables.

    PubMed

    Schlagenhauf, Lukas; Kuo, Yu-Ying; Michel, Silvain; Terrasi, Giovanni; Wang, Jing

    2015-01-01

    This study investigated the particle and fiber release from two carbon fiber reinforced polymer cables that underwent high-energy tensile tests until rupture. The failing event was the source of a large amount of dust whereof a part was suspected to be containing possibly respirable fibers that could cause adverse health effects. The released fibers were suspected to migrate through small openings to the experiment control room and also to an adjacent machine hall where workers were active. To investigate the fiber release and exposure risk of the affected workers, the generated particles were measured with aerosol devices to obtain the particle size and particle concentrations. Furthermore, particles were collected on filter samples to investigate the particle shape and the fiber concentration. Three situations were monitored for the control room and the machine hall: the background concentrations, the impact of the cable failure, and the venting of the exposed rooms afterward. The results showed four important findings: The cable failure caused the release of respirable fibers with diameters below 3 μm and an average length of 13.9 μm; the released particles did migrate to the control room and to the machine hall; the measured peak fiber concentration of 0.76 fibers/cm(3) and the overall fiber concentration of 0.07 fibers/cm(3) in the control room were below the Permissible Exposure Limit (PEL) for fibers without indication of carcinogenicity; and the venting of the rooms was fast and effective. Even though respirable fibers were released, the low fiber concentration and effective venting indicated that the suspected health risks from the experiment on the affected workers was low. However, the effect of long-term exposure is not known therefore additional control measures are recommended.

  6. Annual ecosystem respiration variability of alpine peatland on the eastern Qinghai-Tibet Plateau and its controlling factors.

    PubMed

    Peng, Haijun; Hong, Bing; Hong, Yetang; Zhu, Yongxuan; Cai, Chen; Yuan, Lingui; Wang, Yu

    2015-09-01

    Peatlands are widely developed in the eastern Qinghai-Tibet Plateau, but little is known about carbon budgets for these alpine peatland ecosystems. In this study, we used an automatic chamber system to measure ecosystem respiration in the Hongyuan peatland, which is located in the eastern Qinghai-Tibet Plateau. Annual ecosystem respiration measurements showed a typical seasonal pattern, with the peak appearing in June. The highest respiration was 10.43 μmol CO2/m(2)/s, and the lowest was 0.20 μmol CO2/m(2)/s. The annual average ecosystem respiration was 2.06 μmol CO2/m(2)/s. The total annual respiration was 599.98 g C/m(2), and respiration during the growing season (from May to September) accounted for 78 % of the annual sum. Nonlinear regression revealed that ecosystem respiration has a significant exponential correlation with soil temperature at 10-cm depth (R (2) = 0.98). The Q 10 value was 3.90, which is far higher than the average Q 10 value of terrestrial ecosystems. Ecosystem respiration had an apparent diurnal variation pattern in growing season, with peaks and valleys appearing at approximately 14:00 and 10:00, respectively, which could be explained by soil temperature and soil water content variation at 10-cm depth.

  7. Exposure-Reducing Behaviors among Residents Living near a Coal Ash Storage Site

    ERIC Educational Resources Information Center

    Zierold, Kristina M.; Sears, Clara G.; Brock, Guy N.

    2016-01-01

    Coal ash, a waste product generated from burning coal for energy, is composed of highly respirable particles containing heavy metals, radioactive elements, and polycylic aromatic hydrocarbons. Coal ash is stored in landfills and surface impoundments frequently located near neighborhoods. Fugitive dust from the storage sites exposes neighborhoods,…

  8. The Mine Safety and Health Administration's criterion threshold value policy increases miners' risk of pneumoconiosis.

    PubMed

    Weeks, James L

    2006-06-01

    The Mine Safety and Health Administration (MSHA) proposes to issue citations for non-compliance with the exposure limit for respirable coal mine dust when measured exposure exceeds the exposure limit with a "high degree of confidence." This criterion threshold value (CTV) is derived from the sampling and analytical error of the measurement method. This policy is based on a combination of statistical and legal reasoning: the one-tailed 95% confidence limit of the sampling method, the apparent principle of due process and a standard of proof analogous to "beyond a reasonable doubt." This policy raises the effective exposure limit, it is contrary to the precautionary principle, it is not a fair sharing of the burden of uncertainty, and it employs an inappropriate standard of proof. Its own advisory committee and NIOSH have advised against this policy. For longwall mining sections, it results in a failure to issue citations for approximately 36% of the measured values that exceed the statutory exposure limit. Citations for non-compliance with the respirable dust standard should be issued for any measure exposure that exceeds the exposure limit.

  9. Technology Insertion (TI)/Industrial Process Improvement (IPI) Task Order Number 15, Data Base Documentation Book SA-ALC/MAE & MAT

    DTIC Science & Technology

    1990-12-14

    r . ,,,’ , ,.r ,-z /Ar A i-, ’- -. q <-->- as 7/ 4, ’C ’ 4’ / de /- --, AI c " (/’r)i -l 74 7 C/L CAe 71C, eX X-- r , ’Ie? 74-4 c- 7,’/,, , /’ 74 V1;he...GLASSES SAFETY GOGGLES CHEMICAL SPLASH GOGGLES &rFACE SHIELD RESPIRATOR ORGANIC VAPOR SPRAY PAINT METAL FUME I TOXIC ,._ ____r _ _ _ OTHER (Speci’y...SAFETY GOGGLES CHEMICAL SPLASH GOGGLES - , FACE SHIELD RESPIRATOR ORGANIC VAPOR SPRAY PAINT METAL FUME ’ TOXIC DUST OTHER (Specify) 23. EMERGENCY

  10. Generation rate and particle size distribution of wood dust by handheld sanding operation

    PubMed Central

    Ojima, Jun

    2016-01-01

    Objectives: The International Agency for Research on Cancer (IARC) and Japan Society for Occupational Health (JSOH) classified wood dust as a human carcinogen. Former studies have suggested that sanding with a portable sander is one of the processes that are liable to cause highest exposure to wood dust. However, the wood dust by sanding operation has not been investigated sufficiently. In this study, the generation rate and the particle size distribution of the wood dust produced by handheld sanding operation were observed by laboratory experiments. Methods: Beech and cypress were taken as typical hard and soft wood specimen respectively, and sanded with a portable sander. Three grades of sand paper (coarse, medium, fine) were attached to the sander in turn to be tested. The quantity of the wood dust produced by the sander was measured by weighing the specimen before and after the sanding and then the generation rate of the dust was calculated. Results: Soft wood generated more dust than hard wood due to the difference in abrasion durability. A coarse sand paper produced more dust than a fine sand paper. The particles of less than 1 μm diameter were scarcely observed in the wood dust. When the specimens were sanded with a fine sand paper, the mass median aerodynamic diameters of beech dust and cypress dust were 9.0 μm and 9.8 μm, respectively. Conclusions: Respirable wood dust is able to be controlled by general ventilation with more than 0.7-4.2 m3/min ventilation rate. PMID:27725491

  11. [The new German general threshold limit value for dust--pro and contra the adoption in Austria].

    PubMed

    Godnic-Cvar, Jasminka; Ponocny, Ivo

    2004-01-01

    Since it has been realised that inhalation of inert dust is one of the important confounding variables for the development of chronic bronchitis, the threshold values for occupational exposure to these dusts needs to be further decreased. The German Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area (MAK-Commission) has set a new threshold (MAK-Value) for inert dusts (4 mg/m3 for inhalable dust, 1.5 mg/m3 for respirable dust) in 1997. This value is much lower than the threshold values currently used world-wide. The aim of the present article is to assess the scientific plausibility of the methodology (databases and statistics) used to set these new German MAK-Values, regarding their adoption in Austria. Although we believe that it is substantial to lower the MAK-Value for inert dust in order to prevent the development of chronic bronchitis as a consequence of occupational exposure to inert dusts, the applied methodology used by the German MAK-Commission in 1997 to set the new MAK-Values does not justify the reduction of the threshold limit value. A carefully designed study to establish an appropriate scientific basis for setting a new threshold value for inert dusts in the workplace should be carried out. Meanwhile, at least the currently internationally applied threshold values should be adopted in Austria.

  12. Diacetyl emissions and airborne dust from butter flavorings used in microwave popcorn production.

    PubMed

    Boylstein, Randy; Piacitelli, Chris; Grote, Ardith; Kanwal, Richard; Kullman, Greg; Kreiss, Kathleen

    2006-10-01

    In microwave popcorn workers, exposure to butter flavorings has been associated with fixed obstructive lung disease resembling bronchiolitis obliterans. Inhalation toxicology studies have shown severe respiratory effects in rats exposed to vapors from a paste butter flavoring, and to diacetyl, a diketone found in most butter flavorings. To gain a better understanding of worker exposures, we assessed diacetyl emissions and airborne dust levels from butter flavorings used by several microwave popcorn manufacturing companies. We heated bulk samples of 40 different butter flavorings (liquids, pastes, and powders) to approximately 50 degrees C and used gas chromatography, with a mass selective detector, to measure the relative abundance of volatile organic compounds emitted. Air sampling was conducted for diacetyl and for total and respirable dust during the mixing of powder, liquid, or paste flavorings with heated soybean oil at a microwave popcorn plant. To further examine the potential for respiratory exposures to powders, we measured dust generated during different simulated methods of manual handling of several powder butter flavorings. Powder flavorings were found to give off much lower diacetyl emissions than pastes or liquids. The mean diacetyl emissions from liquids and pastes were 64 and 26 times larger, respectively, than the mean of diacetyl emissions from powders. The median diacetyl emissions from liquids and pastes were 364 and 72 times larger, respectively, than the median of diacetyl emissions from powders. Fourteen of 16 powders had diacetyl emissions that were lower than the diacetyl emissions from any liquid flavoring and from most paste flavorings. However, simulated handling of powder flavorings showed that a substantial amount of the airborne dust generated was of respirable size and could thus pose its own respiratory hazard. Companies that use butter flavorings should consider substituting flavorings with lower diacetyl emissions and the use of ventilation and enclosure engineering controls to minimize exposures. Until controls are fully implemented, companies should institute mandatory respiratory protection for all exposed workers.

  13. Oxidative stress, telomere shortening, and DNA methylation in relation to low-to-moderate occupational exposure to welding fumes.

    PubMed

    Li, Huiqi; Hedmer, Maria; Wojdacz, Tomasz; Hossain, Mohammad Bakhtiar; Lindh, Christian H; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-10-01

    Evidence suggests that exposure to welding fumes is a risk factor for lung cancer. We examined relationships between low-to-moderate occupational exposure to particles from welding fumes and cancer-related biomarkers for oxidative stress, changes in telomere length, and alterations in DNA methylation. We enrolled 101 welders and 127 controls (all currently nonsmoking men) from southern Sweden. We performed personal sampling of respirable dust and measured 8-oxodG concentrations in urine using a simplified liquid chromatography tandem mass spectrometry method. Telomere length in peripheral blood was measured by quantitative polymerase chain reaction. Methylation status of 10 tumor suppressor genes was determined by methylation-sensitive high-resolution melting analysis. All analyses were adjusted for age, body mass index, previous smoking, passive smoking, current residence, and wood burning stove/boiler at home. Welders were exposed to respirable dust at 1.2 mg/m(3) (standard deviation, 3.3 mg/m(3); range, 0.1-19.3), whereas control exposures did not exceed 0.1 mg/m(3) (P < 0.001). Welders and controls did not differ in 8-oxodG levels (β = 1.2, P = 0.17) or relative telomere length (β = -0.053, P = 0.083) in adjusted models. Welders showed higher probability of adenomatous polyposis coli (APC) methylation in the unadjusted model (odds ratio = 14, P = 0.014), but this was not significant in the fully adjusted model (P = 0.052). Every working year as a welder was associated with 0.0066 units shorter telomeres (95% confidence interval -0.013 to -0.00053, P = 0.033). Although there were no clear associations between concentrations of respirable dust and the biomarkers, there were modest signs of associations between oxidative stress, telomere alterations, DNA methylation, and occupational exposure to low-to-moderate levels of particles. © 2015 Wiley Periodicals, Inc.

  14. Forecasting Dust Storms Using the CARMA-Dust Model and MM5 Weather Data

    NASA Astrophysics Data System (ADS)

    Barnum, B. H.; Winstead, N. S.; Wesely, J.; Hakola, A.; Colarco, P.; Toon, O. B.; Ginoux, P.; Brooks, G.; Hasselbarth, L. M.; Toth, B.; Sterner, R.

    2002-12-01

    An operational model for the forecast of dust storms in Northern Africa, the Middle East and Southwest Asia has been developed for the United States Air Force Weather Agency (AFWA). The dust forecast model uses the 5th generation Penn State Mesoscale Meteorology Model (MM5), and a modified version of the Colorado Aerosol and Radiation Model for Atmospheres (CARMA). AFWA conducted a 60 day evaluation of the dust model to look at the model's ability to forecast dust storms for short, medium and long range (72 hour) forecast periods. The study used satellite and ground observations of dust storms to verify the model's effectiveness. Each of the main mesoscale forecast theaters was broken down into smaller sub-regions for detailed analysis. The study found the forecast model was able to forecast dust storms in Saharan Africa and the Sahel region with an average Probability of Detection (POD)exceeding 68%, with a 16% False Alarm Rate (FAR). The Southwest Asian theater had average POD's of 61% with FAR's averaging 10%.

  15. A prospective cohort study among new Chinese coal miners: the early pattern of lung function change.

    PubMed

    Wang, M-L; Wu, Z-E; Du, Q-G; Petsonk, E L; Peng, K-L; Li, Y-D; Li, S-K; Han, G-H; Atffield, M D

    2005-11-01

    To investigate the early pattern of longitudinal change in forced expiratory volume in 1 second (FEV1) among new Chinese coal miners, and the relation between coal mine dust exposure and the decline of lung function. The early pattern of lung function changes in 317 newly hired Chinese underground coal miners was compared to 132 referents. This three year prospective cohort study involved a pre-employment and 15 follow up health surveys, including a questionnaire and spirometry tests. Twice a month, total and respirable dust area sampling was done. The authors used a two stage analysis and a linear mixed effects model approach to analyse the longitudinal spirometry data, and to investigate the changes in FEV1 over time, controlling for age, height, pack years of smoking, mean respirable dust concentration, the room temperature during testing, and the groupxtime interaction terms. FEV1 change over time in new miners is non-linear. New miners experience initial rapid FEV1 declines, primarily during the first year of mining, little change during the second year, and partial recovery during the third year. Both linear and quadratic time trends in FEV1 change are highly significant. Smoking miners lost more FEV1 than non-smokers. Referents, all age less than 20 years, showed continued lung growth, whereas the miners who were under age 20 exhibited a decline in FEV1. Dust and smoking affect lung function in young, newly hired Chinese coal miners. FEV1 change over the first three years of employment is non-linear. The findings have implications for both methods and interpretation of medical screening in coal mining and other dusty work: during the first several years of employment more frequent testing may be desirable, and caution is required in interpreting early FEV1 declines.

  16. Blood antioxidant enzymes as markers of exposure or effect in coal miners.

    PubMed Central

    Perrin-Nadif, R; Auburtin, G; Dusch, M; Porcher, J M; Mur, J M

    1996-01-01

    OBJECTIVE--To investigate if blood Cu++/Zn++ superoxide dismutase, glutathione peroxidase, catalase, and total plasma antioxidant activities could be markers of biological activity resulting from exposure to respirable coal mine dust in active miners, and of pneumoconiosis in retired miners. METHODS--Blood samples were randomly obtained from active surface workers (n = 30) and underground miners (n = 34), and from retired miners without (n = 21), and with (n = 33) pneumoconiosis. Antioxidant enzyme activities and total plasma antioxidants were measured in erythrocytes and plasma. Non-parametric tests were completed by analyses of covariance to compare antioxidants between groups, taking into account potential confounding factors (age, smoking history (pack-years)). RESULTS--Erythrocyte Cu++/Zn++ superoxide dismutase activity was significantly higher in the group of underground miners than the group of surface workers. The differences in total plasma antioxidants and plasma glutathione peroxidase activity between both groups were related to age. Glutathione peroxidase activity increased in the plasma of retired miners with pneumoconiosis, compared with retired miners without pneumoconiosis. No differences were found either in erythrocyte antioxidant enzyme activities or in total plasma antioxidants between the groups of retired miners without and with pneumoconiosis. CONCLUSIONS--In this study, erythrocyte Cu++/Zn++ superoxide dismutase activity may be considered as a marker of effect of respirable coal mine dust in exposed workers. This result is in agreement with the hypothesis that reactive oxygen species are involved in cell injury induced by coal mine dust, and may be predictive of the degree of inflammation and pneumoconiosis induced by coal mine dust. The increase in glutathione peroxidase activity in the plasma of retired miners with pneumoconiosis may be the result of a response to the increasing hydrogen peroxide (H2O2) production due to the disease process. PMID:8563856

  17. Exposure to welding fumes is associated with hypomethylation of the F2RL3 gene: a cardiovascular disease marker

    PubMed Central

    Hossain, Mohammad B; Li, Huiqi; Hedmer, Maria; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-01-01

    Background Welders are at risk for cardiovascular disease. Recent studies linked tobacco smoke exposure to hypomethylation of the F2RL3 (coagulation factor II (thrombin) receptor-like 3) gene, a marker for cardiovascular disease prognosis and mortality. However, whether welding fumes cause hypomethylation of F2RL3 remains unknown. Methods We investigated 101 welders (median span of working as a welder: 7 years) and 127 unexposed controls (non-welders with no obvious exposure to respirable dust at work), age range 23–60 years, all currently non-smoking, in Sweden. The participants were interviewed about their work history, lifestyle factors and diseases. Personal sampling of respirable dust was performed for the welders. DNA methylation of F2RL3 in blood was assessed by pyrosequencing of four CpG sites, CpG_2 (corresponds to cg03636183) to CpG_5, in F2RL3. Multivariable linear regression analysis was used to assess the association between exposure to welding fumes and F2RL3 methylation. Results Welders had 2.6% lower methylation of CpG_5 than controls (p<0.001). Higher concentrations of measured respirable dust among the welders were associated with hypomethylation of CpG_2, CpG_4 and CpG_5 (β=−0.49 to −1.4, p<0.012); p<0.029 adjusted for age, previous smoking, passive smoking, education, current residence and respirator use. Increasing the number of years working as a welder was associated with hypomethylation of CpG_4 (linear regression analysis, β=−0.11, p=0.039, adjusted for previous smoking). Previous tobacco smokers had 1.5–4.7% (p<0.014) lower methylation of 3 of the 4 CpG sites in F2RL3 (CpG_2, CpG_4 and CpG_5) compared to never-smokers. A non-significant lower risk of cardiovascular disease with more methylation was observed for all CpG sites. Conclusions Welding fumes exposure and previous smoking were associated with F2RL3 hypomethylation. This finding links low-to-moderate exposure to welding fumes to adverse effects on the cardiovascular system, and suggests a potential mechanistic pathway for this link, via epigenetic effects on F2RL3 expression. PMID:26395445

  18. Potential pulmonary effects of man-made organic fiber (MMOF) dusts.

    PubMed

    Warheit, D B; Hart, G A; Hesterberg, T W; Collins, J J; Dyer, W M; Swaen, G M; Castranova, V; Soiefer, A I; Kennedy, G L

    2001-11-01

    In the first half of the twentieth century epidemiologic evidence linked elevated incidences of pulmonary fibrosis and cancer with inhalation of chrysotile and crocidolite asbestos, a family of naturally occurring inorganic fibrous materials. As the serpentine and amphibole forms of asbestos were phased out, synthetic vitreous fibers (SVFs; fiber glass, mineral wool, and refractory fiber) became increasingly utilized, and concerns were raised that they too might cause adverse health effects. Extensive toxicological research on SVFs has demonstrated that their pulmonary effects are directly related to fiber dose in the lung over time. This is the result of deposition (thin fibers deposit in the lower lung more efficiently than thick fibers) and lung-persistence ("biopersistence" is directly related to fiber length and inversely related to dissolution and fragmentation rates). In rat inhalation studies, asbestos was determined to be 7- to 10-fold more biopersistent in the lung than SVFs. Other than its effect on biopersistence, fiber composition did not appear to play a direct role in the biological activity of SVFs. Recently, the utilization of man-made organic fibers (MMOFs) (also referred to by some as synthetic organic fibers) has increased rapidly for a variety of applications. In contrast to SVFs, research on the potential pulmonary effects of MMOFs is relatively limited, because traditionally MMOFs were manufactured in diameters too thick to be respirable (inhalable into the lower lung). However, new developments in the MMOF industry have resulted in the production of increasingly fine-diameter fibers for special applications, and certain post-manufacturing processes (e.g., chopping) generate respirable-sized MMOF dust. Until the mid-1990s, there was no consistent evidence of human health affects attributed to occupational exposure to MMOFs. Very recently, however, a unique form of interstitial lung disease has been reported in nylon flock workers in three different plants, and respirable-sized nylon shreds (including fibers) were identified in workplace air samples. Whether nylon dust or other occupational exposures are responsible for the development of lung disease in these workers remains to be determined. It is also unknown whether the biological mechanisms that determine the respirability and toxicity of SVFs apply to MMOFs. Thus, it is appropriate and timely to review the current data regarding MMOF workplace exposure and pulmonary health effects, including the database on epidemiological, exposure assessment, and toxicology studies.

  19. Estimate of safe human exposure levels for lunar dust based on comparative benchmark dose modeling.

    PubMed

    James, John T; Lam, Chiu-Wing; Santana, Patricia A; Scully, Robert R

    2013-04-01

    Brief exposures of Apollo astronauts to lunar dust occasionally elicited upper respiratory irritation; however, no limits were ever set for prolonged exposure to lunar dust. The United States and other space faring nations intend to return to the moon for extensive exploration within a few decades. In the meantime, habitats for that exploration, whether mobile or fixed, must be designed to limit human exposure to lunar dust to safe levels. Herein we estimate safe exposure limits for lunar dust collected during the Apollo 14 mission. We instilled three respirable-sized (∼2 μ mass median diameter) lunar dusts (two ground and one unground) and two standard dusts of widely different toxicities (quartz and TiO₂) into the respiratory system of rats. Rats in groups of six were given 0, 1, 2.5 or 7.5 mg of the test dust in a saline-Survanta® vehicle, and biochemical and cellular biomarkers of toxicity in lung lavage fluid were assayed 1 week and one month after instillation. By comparing the dose--response curves of sensitive biomarkers, we estimated safe exposure levels for astronauts and concluded that unground lunar dust and dust ground by two different methods were not toxicologically distinguishable. The safe exposure estimates were 1.3 ± 0.4 mg/m³ (jet-milled dust), 1.0 ± 0.5 mg/m³ (ball-milled dust) and 0.9 ± 0.3 mg/m³ (unground, natural dust). We estimate that 0.5-1 mg/m³ of lunar dust is safe for periodic human exposures during long stays in habitats on the lunar surface.

  20. [Effects of simulated acid rain on respiration rate of cropland system with different soil pH].

    PubMed

    Zhu, Xue-zhu; Zhang, Gao-chuan; Li, Hui

    2009-10-15

    To evaluate the effects of acid rain on the respiration rate of cropland system, an outdoor pot experiment was conducted with paddy soils of pH 5.48 (S1), pH 6.70 (S1) and pH 8.18 (S3) during the 2005-2007 wheat-growing seasons. The cropland system was exposed to acid rain by spraying the wheat foliage and irrigating the soil with simulated rainwater of T1 (pH 6.0), T2 (pH 6.0, ionic concentration was twice as rainwater T1), and T3 (pH 4.4, ionic concentration was twice as rainwater T1), respectively. The static opaque chamber-gas chromatograph method was used to measure CO2 fluxes from cropland system. The results showed that acid rain affected the respiration rate of cropland system through crop plant, and the cropland system could adapt to acid rain. Acid rainwater significantly increased the average respiration rate in alkaline soil (S3) cropland system, while it had no significant effects on the average respiration rate in neutral soil (S2) and acidic soil (S1) cropland systems. During 2005-2006, after the alkaline soil cropland system was treated with rainwater T3, the average respiration rate was 23.6% and 27.6% higher than that of alkaline soil cropland system treated with rainwater T1 and T2, respectively. During March to April, the respiration rate was enhanced with the increase of rainwater ionic concentration, while it was dropped with the decrease of rainwater pH value in acidic soil cropland system. It was demonstrated that soil pH and crop plant played important roles on the respiration rate of cropland system.

  1. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santoro, J. P.; McNamara, J.; Yorke, E.

    2012-10-15

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged imagesmore » for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.« less

  2. Microbes and Microstructure: Dust's Role in the Snowpack Evolution

    NASA Astrophysics Data System (ADS)

    Lieblappen, R.; Courville, Z.; Fegyveresi, J. M.; Barbato, R.; Thurston, A.

    2017-12-01

    Dust is a primary vehicle for transporting microbial communities to polar and alpine snowpacks both through wind distribution (dry deposition) and snowfall events (wet deposition). The resulting microbial community diversity in the snowpack may then resemble the source material properties rather than its new habitat. Dust also has a strong influence on the microstructural properties of snow, resulting in changes to radiative and mechanical properties. As local reductions in snowpack albedo lead to enhanced melting and a heterogeneous snow surface, the microbial communities are also impacted. Here we study the impact of the changing microstructure in the snowpack, its influence on microbial function, and the fate of dust particles within the snow matrix. We seek to quantify the changes in respiration and water availability with the onset of melt. Polar samples were collected from the McMurdo Ice Shelf, Antarctica in February, 2017, while alpine samples were collected from Silverton, CO from October to May, 2017 as part of the Colorado Dust on Snow (CDOS) network. At each site, coincident meteorological data provides temperature, wind, and radiative measurements. Samples were collected immediately following dust deposition events and after subsequent snowpack evolution. We used x-ray micro-computed tomography to quantify the microstructural evolution of the snow, while also imaging the microstructural distribution of the dust within the snow. The dust was then collected and analyzed for chemical and microbial activity.

  3. Fogging formulations for fixation of particulate contamination in ductwork and enclosures

    DOEpatents

    Maresca, Jr., Joseph W.; Kostelnik, Lori M.; Kriskivich, James R.; Demmer, Rick L.; Tripp, Julia L.

    2015-09-08

    A method and an apparatus using aqueous fixatives for fogging of ventilation ductwork, enclosures, or buildings containing dust, lint, and particulates that may be contaminated by radionuclides and other dangerous or unsafe particulate contaminants, which method and apparatus are capable of (1) obtaining full coverage within the ductwork and (2) penetrating and fixing the lint, dust and large particles present in the ductwork so that no airborne particles are released during or after the application of the fixative. New aqueous fogging solutions outperform conventional glycerin-based solutions. These aqueous solutions will fog using conventional methods of application and contain a surfactant to aid wetting and penetration of the lint and dust, a binder to stabilize loose or respirable particles, and an agent to aid in fogging and enhance adhesiveness. The solutions are safe and easy to use.

  4. Aerosol Chemistry over a High Altitude Station at Northeastern Himalayas, India

    PubMed Central

    Chatterjee, Abhijit; Adak, Anandamay; Singh, Ajay K.; Srivastava, Manoj K.; Ghosh, Sanjay K.; Tiwari, Suresh; Devara, Panuganti C. S.; Raha, Sibaji

    2010-01-01

    Background There is an urgent need for an improved understanding of the sources, distributions and properties of atmospheric aerosol in order to control the atmospheric pollution over northeastern Himalayas where rising anthropogenic interferences from rapid urbanization and development is becoming an increasing concern. Methodology/Principal Findings An extensive aerosol sampling program was conducted in Darjeeling (altitude ∼2200 meter above sea level (masl), latitude 27°01′N and longitude 88°15′E), a high altitude station in northeastern Himalayas, during January–December 2005. Samples were collected using a respirable dust sampler and a fine dust sampler simultaneously. Ion chromatograph was used to analyze the water soluble ionic species of aerosol. The average concentrations of fine and coarse mode aerosol were found to be 29.5±20.8 µg m−3 and 19.6±11.1 µg m−3 respectively. Fine mode aerosol dominated during dry seasons and coarse mode aerosol dominated during monsoon. Nitrate existed as NH4NO3 in fine mode aerosol during winter and as NaNO3 in coarse mode aerosol during monsoon. Gas phase photochemical oxidation of SO2 during premonsoon and aqueous phase oxidation during winter and postmonsoon were the major pathways for the formation of SO4 2− in the atmosphere. Long range transport of dust aerosol from arid regions of western India was observed during premonsoon. The acidity of fine mode aerosol was higher in dry seasons compared to monsoon whereas the coarse mode acidity was higher in monsoon compared to dry seasons. Biomass burning, vehicular emissions and dust particles were the major types of aerosol from local and continental regions whereas sea salt particles were the major types of aerosol from marine source regions. Conclusions/Significance The year-long data presented in this paper provide substantial improvements to the heretofore poor knowledge regarding aerosol chemistry over northeastern Himalayas, and should be useful to policy makers in making control strategies. PMID:20585397

  5. Aerosol chemistry over a high altitude station at northeastern Himalayas, India.

    PubMed

    Chatterjee, Abhijit; Adak, Anandamay; Singh, Ajay K; Srivastava, Manoj K; Ghosh, Sanjay K; Tiwari, Suresh; Devara, Panuganti C S; Raha, Sibaji

    2010-06-16

    There is an urgent need for an improved understanding of the sources, distributions and properties of atmospheric aerosol in order to control the atmospheric pollution over northeastern Himalayas where rising anthropogenic interferences from rapid urbanization and development is becoming an increasing concern. An extensive aerosol sampling program was conducted in Darjeeling (altitude approximately 2200 meter above sea level (masl), latitude 27 degrees 01'N and longitude 88 degrees 15'E), a high altitude station in northeastern Himalayas, during January-December 2005. Samples were collected using a respirable dust sampler and a fine dust sampler simultaneously. Ion chromatograph was used to analyze the water soluble ionic species of aerosol. The average concentrations of fine and coarse mode aerosol were found to be 29.5+/-20.8 microg m(-3) and 19.6+/-11.1 microg m(-3) respectively. Fine mode aerosol dominated during dry seasons and coarse mode aerosol dominated during monsoon. Nitrate existed as NH(4)NO(3) in fine mode aerosol during winter and as NaNO(3) in coarse mode aerosol during monsoon. Gas phase photochemical oxidation of SO(2) during premonsoon and aqueous phase oxidation during winter and postmonsoon were the major pathways for the formation of SO(4)(2-) in the atmosphere. Long range transport of dust aerosol from arid regions of western India was observed during premonsoon. The acidity of fine mode aerosol was higher in dry seasons compared to monsoon whereas the coarse mode acidity was higher in monsoon compared to dry seasons. Biomass burning, vehicular emissions and dust particles were the major types of aerosol from local and continental regions whereas sea salt particles were the major types of aerosol from marine source regions. The year-long data presented in this paper provide substantial improvements to the heretofore poor knowledge regarding aerosol chemistry over northeastern Himalayas, and should be useful to policy makers in making control strategies.

  6. Toxicity of Lunar Dust in Lungs Assessed by Examining Biomarkers in Exposed Mice

    NASA Technical Reports Server (NTRS)

    Lam, C.-W.; James, J. T.; Zeidler-Erdely, P. C.; Castranova, V.; Young, S. H.; Quan, C. L.; Khan-Mayberry, N.; Taylor, L. A.

    2009-01-01

    NASA plans to build an outpost on the Moon for prolonged human habitation and research. The lunar surface is covered by a layer of soil, of which the finest portion is highly reactive dust. NASA has invited NIOSH to collaboratively investigate the toxicity of lunar dust. Dust samples of respirable sizes were aerodynamically isolated from two lunar soil samples of different maturities (cosmic exposure ages) collected during the Apollo 16 mission. The lunar dust samples, titanium dioxide, or quartz, suspended in normal saline or in Survanta (a bovine lung surfactant), were given to groups of 5 mice (C-57 male) by intrapharyngeal aspiration at 1, 0.3, or 0.1 mg/mouse. The mice were euthanized 7 or 30 days later, and their lungs were lavaged to assess the toxicity biomarkers in bronchioalveolar lavage fluids. The acellular fractions were assayed for total proteins, lactate dehydrogenase activities, and cytokines; the cellular portions were assessed for total cell counts and cell differentials. Results from the high-dose groups showed that lunar dust, suspended in saline, was more toxic than TiO 2, but less toxic than quartz. Lunar dust particles aggregate and settle out rapidly in water or saline, but not in Survanta. Lunar dust suspended in Survanta manifested greater toxicity than lunar dust in saline. The increase in toxicity presumably was due to that Survanta gave a better particle dispersion in the lungs. The two lunar dust samples showed similar toxicity. The overall results showed that lunar dust is more toxic than TiO 2 but less toxic than quartz.

  7. Clinically important respiratory effects of dust exposure and smoking in British coal miners

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marine, W.M.; Gurr, D.; Jacobsen, M.

    A unique data set of 3380 British coal miners has been reanalyzed with major focus on nonpneumoconiotic respiratory conditions. The aim was to assess the independent contribution of smoking and exposure to respirable dust to clinically significant measures of respiratory dysfunction. Exposure to coal-mine dust was monitored over a 10-yr period. Medical surveys provided estimates of prior dust exposure and recorded respiratory symptoms. Each man's FEV1 was compared with the level predicted for his age and height by an internally derived prediction equation for FEV1. Four respiratory indices were considered at the end of the 10-yr period: FEV1 less thanmore » 80%, chronic bronchitis, chronic bronchitis with FEV1 less than 80%, and FEV1 less than 65%. Results were uniformly incorporated into logistic regression equations for each condition. The equations include coefficients for age, dust, and when indicated, an interaction term for age and dust. Dust-related increases in prevalence of each of the 4 conditions were statistically significant and were similar for smokers and nonsmokers at the mean age (47 yr). There was no evidence that smoking potentiates the effect of exposure to dust. Estimates of prevalences at the mean age of all 4 measures of respiratory dysfunction were greater in smokers. At intermediate and high dust exposure the prevalence of the 4 conditions in nonsmokers approached the prevalence in smokers at hypothetically zero dust exposure. Both smoking and dust exposure can cause clinically important respiratory dysfunction and their separate contributions to obstructive airway disease in coal miners appear to be additive.« less

  8. Community, environmental, and occupational health risks associated with fossil fuel energy production

    NASA Astrophysics Data System (ADS)

    Shepherd, Mark A.

    Short-term and long-term health risks associated with fossil fuel power production can be grouped into three broad categories: risks to the surrounding community, the natural environment and to plant workers. The results of three studies examining the primary short-term or long-term impacts of fossil fuel power plants are presented within this dissertation. The first study estimates the plausible community health effects associated with peak SO2 emissions from three coal-fired power plants in the Baltimore, Maryland area. Concentrations from mobile and stationary air monitoring were compared to human clinical studies that demonstrated respiratory morbidity. Results indicate that exposure concentrations are below levels associated with respiratory symptoms. A single measurement at one monitoring site, however, may indicate risk of asymptomatic lung function decrement for SO2-sensitive asthmatics. The second study estimates the relationship between operational, environmental and temporal factors at a Texas coastal power plant and fish and shellfish impingement. Impingement is a long-term risk to fish populations near power plants. When large quantities of water are withdrawn from water bodies for cooling, fish and shellfish may be harmed if impinged against screens intended to remove debris. In this study, impingement of fish and shellfish was best explained by dissolved oxygen concentration, sampling month and sampling time. When examined separately, temperature and sampling month were most important in explaining fish impingement, while for shellfish, sampling month and sampling time were most important. Operational factors were not significant predictors of impingement. The third study examines whether the number of worker similar exposure groups classified using observation methods was the same as groups classified using personal exposure monitoring. Using observational techniques and personal monitoring, power plant workers were grouped according to exposure similarity for respirable silica, respirable particulates, total dust, chromium and arsenic. For respirable particulates, the number of groups estimated using observational techniques is similar to the number estimated using personal monitoring. For respirable silica, total dust, and arsenic, observational techniques indicated more groups than indicated using personal monitoring. No significant exposure differences to chromium were found. Except for respirable silica, the number of similarly exposed groups among power plants is comparable.

  9. Respirable Crystalline Silica Exposures During Asphalt Pavement Milling at Eleven Highway Construction Sites

    PubMed Central

    Hammond, Duane R.; Shulman, Stanley A.; Echt, Alan S.

    2016-01-01

    Asphalt pavement milling machines use a rotating cutter drum to remove the deteriorated road surface for recycling. The removal of the road surface has the potential to release respirable crystalline silica, to which workers can be exposed. This paper describes an evaluation of respirable crystalline silica exposures to the operator and ground worker from two different half-lane and larger asphalt pavement milling machines that had ventilation dust controls and water-sprays designed and installed by the manufacturers. Manufacturer A completed milling for eleven days at four highway construction sites in Wisconsin, while Manufacturer B completed milling for ten days at seven highway construction sites in Indiana. To evaluate the dust controls, full-shift personal breathing zone air samples were collected from an operator and ground worker during the course of normal employee work activities of asphalt pavement milling at eleven different sites. Forty-two personal breathing zone air samples were collected over 21 days (sampling on an operator and ground worker each day). All samples were below 50 µg/m3 for respirable crystalline silica, the National Institute for Occupational Safety and Health recommended exposure limit. The geometric mean personal breathing zone air sample was 6.2 µg/m3 for the operator and 6.1 µg/m3 for the ground worker for the Manufacturer A milling machine. The geometric mean personal breathing zone air sample was 4.2 µg/m3 for the operator and 9.0 µg/m3 for the ground worker for the Manufacturer B milling machine. In addition, upper 95% confidence limits for the mean exposure for each occupation were well below 50 µg/m3 for both studies. The silica content in the bulk asphalt material being milled ranged from 7% to 23% silica for roads milled by Manufacturer A and from 5% to 12% silica for roads milled by Manufacturer B. The results indicate that engineering controls consisting of ventilation controls in combination with water-sprays are capable of controlling occupational exposures to respirable crystalline silica generated by asphalt pavement milling machines on highway construction sites. PMID:26913983

  10. Respirable crystalline silica exposures during asphalt pavement milling at eleven highway construction sites.

    PubMed

    Hammond, Duane R; Shulman, Stanley A; Echt, Alan S

    2016-07-01

    Asphalt pavement milling machines use a rotating cutter drum to remove the deteriorated road surface for recycling. The removal of the road surface has the potential to release respirable crystalline silica, to which workers can be exposed. This article describes an evaluation of respirable crystalline silica exposures to the operator and ground worker from two different half-lane and larger asphalt pavement milling machines that had ventilation dust controls and water-sprays designed and installed by the manufacturers. Manufacturer A completed milling for 11 days at 4 highway construction sites in Wisconsin, and Manufacturer B completed milling for 10 days at 7 highway construction sites in Indiana. To evaluate the dust controls, full-shift personal breathing zone air samples were collected from an operator and ground worker during the course of normal employee work activities of asphalt pavement milling at 11 different sites. Forty-two personal breathing zone air samples were collected over 21 days (sampling on an operator and ground worker each day). All samples were below 50 µg/m(3) for respirable crystalline silica, the National Institute for Occupational Safety and Health recommended exposure limit. The geometric mean personal breathing zone air sample was 6.2 µg/m(3) for the operator and 6.1 µg/m(3) for the ground worker for the Manufacturer A milling machine. The geometric mean personal breathing zone air sample was 4.2 µg/m(3) for the operator and 9.0 µg/m(3) for the ground worker for the Manufacturer B milling machine. In addition, upper 95% confidence limits for the mean exposure for each occupation were well below 50 µg/m(3) for both studies. The silica content in the bulk asphalt material being milled ranged from 7-23% silica for roads milled by Manufacturer A and from 5-12% silica for roads milled by Manufacturer B. The results indicate that engineering controls consisting of ventilation controls in combination with water-sprays are capable of controlling occupational exposures to respirable crystalline silica generated by asphalt pavement milling machines on highway construction sites.

  11. Lung cancer incidence among Norwegian silicon carbide industry workers: associations with particulate exposure factors

    PubMed Central

    Kjærheim, Kristina; Føreland, Solveig; Eduard, Wijnand; Kjuus, Helge

    2012-01-01

    Objectives An increased lung cancer risk associated with total dust exposure in the silicon carbide (SiC) industry has previously been reported. The aim of the present study was to examine the relative importance of specific exposure factors by using a comprehensive, historic job exposure matrix based on about 8000 measurements. Methods Cumulative exposure to total and respirable dust, respirable quartz, cristobalite, and SiC particles and SiC fibres was assessed for 1687 long-term workers employed during 1913–2003 in the Norwegian SiC industry. Standardised incidence ratios for lung cancer, with follow-up during 1953–2008, were calculated stratified by cumulative exposure categories. Poisson regression analyses were performed using both categorised and log-transformed cumulative exposure variables. Results The lung cancer incidence was about twofold increased at the highest level of exposure to each of the exposure factors (standardised incidence ratios 1.9–2.3 for all agents). Internal analyses showed associations between exposure level and lung cancer incidence for all investigated factors, but a significant trend only for total dust and cristobalite. In multivariate analyses, cristobalite showed the most consistent associations, followed by SiC fibres. Conclusions The results indicated that crystalline silica in the form of cristobalite was the most important occupational exposure factor responsible for lung cancer excess in the Norwegian SiC industry. SiC fibres seemed to have an additional effect. PMID:22611173

  12. Iron mineralogy and bioaccessibility of dust generated from soils as determined by reflectance spectroscopy and magnetic and chemical properties--Nellis Dunes recreational area, Nevada

    USGS Publications Warehouse

    Goldstein, Harland L.; Reynolds, Richard L.; Morman, Suzette A.; Moskowitz, Bruce; Kokaly, Raymond F.; Goossens, Dirk; Buck, Brenda J.; Flagg, Cody; Till, Jessica; Yauk, Kimberly; Berquó, Thelma S.

    2013-01-01

    Atmospheric mineral dust exerts many important effects on the Earth system, such as atmospheric temperatures, marine productivity, and melting of snow and ice. Mineral dust also can have detrimental effects on human health through respiration of very small particles and the leaching of metals in various organs. These effects can be better understood through characterization of the physical and chemical properties of dust, including certain iron oxide minerals, for their extraordinary radiative properties and possible effects on lung inflammation. Studies of dust from the Nellis Dunes recreation area near Las Vegas, Nevada, focus on characteristics of radiative properties (capacity of dust to absorb solar radiation), iron oxide mineral type and size, chemistry, and bioaccessibility of metals in fluids that simulate human gastric, lung, and phagolysosomal fluids. In samples of dust from the Nellis Dunes recreation area with median grain sizes of 2.4, 3.1, and 4.3 micrometers, the ferric oxide minerals goethite and hematite, at least some of it nanosized, were identified. In one sample, in vitro bioaccessibility experiments revealed high bioaccessibility of arsenic in all three biofluids and higher leachate concentration and bioaccessibility for copper, uranium, and vanadium in the simulated lung fluid than in the phagolysosomal fluid. The combination of methods used here to characterize mineral dust at the Nellis Dunes recreation area can be applied to global dust and broad issues of public health.

  13. Environmental monitoring of secondhand smoke exposure

    PubMed Central

    Apelberg, Benjamin J; Hepp, Lisa M; Avila-Tang, Erika; Gundel, Lara; Hammond, S Katharine; Hovell, Melbourne F; Hyland, Andrew; Klepeis, Neil E; Madsen, Camille C; Navas-Acien, Ana; Repace, James; Samet, Jonathan M

    2013-01-01

    The complex composition of secondhand smoke (SHS) provides a range of constituents that can be measured in environmental samples (air, dust and on surfaces) and therefore used to assess non-smokers' exposure to tobacco smoke. Monitoring SHS exposure (SHSe) in indoor environments provides useful information on the extent and consequences of SHSe, implementing and evaluating tobacco control programmes and behavioural interventions, and estimating overall burden of disease caused by SHSe. The most widely used markers have been vapour-phase nicotine and respirable particulate matter (PM). Numerous other environmental analytes of SHS have been measured in the air including carbon monoxide, 3-ethenylpyridine, polycyclic aromatic hydrocarbons, tobacco-specific nitrosamines, nitrogen oxides, aldehydes and volatile organic compounds, as well as nicotine in dust and on surfaces. The measurement of nicotine in the air has the advantage of reflecting the presence of tobacco smoke. While PM measurements are not as specific, they can be taken continuously, allowing for assessment of exposure and its variation over time. In general, when nicotine and PM are measured in the same setting using a common sampling period, an increase in nicotine concentration of 1 μg/m3 corresponds to an average increase of 10 μg/m3 of PM. This topic assessment presents a comprehensive summary of SHSe monitoring approaches using environmental markers and discusses the strengths and weaknesses of these methods and approaches. PMID:22949497

  14. Characterisation of airborne particulate pollution in the Cu smelter and former mining town of Karabash, South Ural Mountains of Russia.

    PubMed

    Williamson, B J; Udachin, V; Purvis, O W; Spiro, B; Cressey, G; Jones, G C

    2004-11-01

    Airborne total suspended particulates (TSP), dusts from smelter blast furnace and converter stacks, and filtrates of snow melt waters have been characterised in the Cu smelter and former mining town of Karabash, Russia. TSP was collected at sites up- and downwind of the smelter and large waste and tailings dumps (Oct. 2000 and July 2001). Methods for particle size, mineralogical and elemental determinations have been tested and described, and a new PSD-MicroSOURCE XRD technique developed for the mineralogical analysis of microsamples on filter substrates. TSP in downwind samples has a mean equivalent spherical diameter of 0.5 microm (s.d. = 0.2) and was found to be 100% respirable. The main element of human health/environmental concern, above Russian maximum permitted levels (1 microg m(-3), average over any time period), was Pb which was measured at 16-30 microg m(-3) in downwind samples. Individual particulates mainly consisted of complex mixtures of anglesite (PbSO4), Zn2SnO4 and poorly ordered Zn sulphates. From experimental and theoretical considerations, a high proportion of contained Pb, Zn, Cd and As in this material is considered to be in a readily bioavailable form. Chemical and mineralogical differences between the TSP, stack dusts and snow samples are discussed, as well as the implications for human and regional environmental health.

  15. Velocity-amplified microbial respiration rates in the lower Amazon River: Amazon River respiration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, Nicholas D.; Sawakuchi, Henrique O.; Neu, Vania

    Most measurements of respiration rates in large tropical rivers do not account for the influence of river flow conditions on microbial activity. We developed a ship-board spinning incubation system for measuring O2 drawdown under different rotation velocities and deployed the system along the lower Amazon River during four hydrologic periods. Average respiration rates in incubation chambers rotated at 0.22 and 0.66 m s-1 were 1.4 and 2.4 times higher than stationary chambers, respectively. On average, depth-integrated respiration rates in chambers spun at 0.22 and 0.66 m s-1 accounted for 64 ± 22% and 104 ± 36% of CO2 outgassing rates,more » respectively, in mainstem sites. Continuous measurements of in situ pCO2 were also made along with cross-channel profiles of river velocity. A positive correlation between river velocity and pCO2 was observed along the lower river (r2=0.67-0.96) and throughout a tidal cycle.« less

  16. Boreal and temperate trees show strong acclimation of respiration to warming.

    PubMed

    Reich, Peter B; Sendall, Kerrie M; Stefanski, Artur; Wei, Xiaorong; Rich, Roy L; Montgomery, Rebecca A

    2016-03-31

    Plant respiration results in an annual flux of carbon dioxide (CO2) to the atmosphere that is six times as large as that due to the emissions from fossil fuel burning, so changes in either will impact future climate. As plant respiration responds positively to temperature, a warming world may result in additional respiratory CO2 release, and hence further atmospheric warming. Plant respiration can acclimate to altered temperatures, however, weakening the positive feedback of plant respiration to rising global air temperature, but a lack of evidence on long-term (weeks to years) acclimation to climate warming in field settings currently hinders realistic predictions of respiratory release of CO2 under future climatic conditions. Here we demonstrate strong acclimation of leaf respiration to both experimental warming and seasonal temperature variation for juveniles of ten North American tree species growing for several years in forest conditions. Plants grown and measured at 3.4 °C above ambient temperature increased leaf respiration by an average of 5% compared to plants grown and measured at ambient temperature; without acclimation, these increases would have been 23%. Thus, acclimation eliminated 80% of the expected increase in leaf respiration of non-acclimated plants. Acclimation of leaf respiration per degree temperature change was similar for experimental warming and seasonal temperature variation. Moreover, the observed increase in leaf respiration per degree increase in temperature was less than half as large as the average reported for previous studies, which were conducted largely over shorter time scales in laboratory settings. If such dampening effects of leaf thermal acclimation occur generally, the increase in respiration rates of terrestrial plants in response to climate warming may be less than predicted, and thus may not raise atmospheric CO2 concentrations as much as anticipated.

  17. Differential Response of Human Nasal and Bronchial Epithelial Cells upon Exposure to Size-fractionated Dairy Dust

    PubMed Central

    Hawley, Brie; Schaeffer, Joshua; Poole, Jill A.; Dooley, Gregory P.; Reynolds, Stephen; Volckens, John

    2015-01-01

    Exposure to organic dusts is associated with increased respiratory morbidity and mortality in agricultural workers. Organic dusts in dairy farm environments are complex, polydisperse mixtures of toxic and immunogenic compounds. Previous toxicological studies focused primarily on exposures to the respirable size fraction, however, organic dusts in dairy farm environments are known to contain larger particles. Given the size distribution of dusts from dairy farm environments, the nasal and bronchial epithelia represent targets of agricultural dust exposures. In this study, well-differentiated normal human bronchial epithelial cells and human nasal epithelial cells were exposed to two different size fractions (PM10 and PM>10) of dairy parlor dust using a novel aerosol-to-cell exposure system. Levels of pro-inflammatory transcripts (IL-8, IL-6, and TNF-α) were measured two hr after exposure. Lactate dehydrogenase (LDH) release was also measured as an indicator of cytotoxicity. Cell exposure to dust was measured in each size fraction as a function of mass, endotoxin, and muramic acid levels. To our knowledge, this is the first study to evaluate the effects of distinct size fractions of agricultural dust on human airway epithelial cells. Our results suggest that both PM10 and PM>10 size fractions elicit a pro-inflammatory response in airway epithelial cells and that the entire inhalable size fraction needs to be considered when assessing potential risks from exposure to agricultural dusts. Further, data suggest that human bronchial cells respond differently to these dusts than human nasal cells and, therefore, the two cell types need to be considered separately in airway cell models of agricultural dust toxicity. PMID:25965193

  18. Dust fallout in Kuwait city: deposition and characterization.

    PubMed

    Al-Awadhi, Jasem M; Alshuaibi, Arafat A

    2013-09-01

    Dust fallouts in Kuwait city was monitored on monthly basis during the period from March 2011 to February 2012 at 10 locations. The results of this study reveal that: (1) monthly dust deposition rates ranged from 0.002 to 0.32 kg/m(2) with average deposition rate of 0.053 kg/m(2) and annual average deposition rate of 0.59 kg/m(2), ranking the first out of 56 dust deposition rates observed throughout the world; (2) on average, about 55.9% of the settled dust have fine to very fine sand fraction sizes, while silt and clay comprise an average of 37.4 and 1.4% of the total sample, respectively; (3) the concentrations for Zn and Mo out of 15 other elements analyzed from the dust were up to 11 times higher than their soil background values in Kuwait, while Pb and Ni were about seven times higher; (4) Mo, Ni, Pb and Zn show maximum enrichment relative to the upper continental crustal component (Mn); (5) Sr, Zr and Zn show highest concretions among all collected samples; and (6) quartz and calcite were the dominant minerals in the dust samples. The distribution of the heavy metals in dust seems to be controlled mainly by the land uses and the volume of traffic emissions. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Navy Occupational Health Information Management System (NOHIMS). Environmental Exposure Module. Operators’ Guide

    DTIC Science & Technology

    1987-01-01

    be recorded. Obviously, without the close transaction the module cannot maintain the current status of each boundary. 4-1 0% Sle.t SOUNDARY tD NUMBER...HOp: 134 (MIMS) ... 0KI YES//-.. (YES) ARE YOU ADDING A NEW EMPLOYEE (THE 11TH FOR THIS IOUNDARY)9 Y (YES) RESPIRATOR TYPE: 1r~PF HALF FACE, DUST FUME

  20. African Dust Transport Captured by Rare Earth Elemental Concentrations in Coral Microatolls

    NASA Astrophysics Data System (ADS)

    Ouellette, G., Jr.; DeLong, K.; Herrmann, A.; Huang, C. Y.; Shen, C. C.

    2017-12-01

    Winds are integral components of the climate system; unfortunately, windsare also among the climate variables that are most difficult to study prior to the instrumentalrecord. Paleoclimatologists use sedimentary dust records (e.g., lake and ocean cores) tounderstand past wind circulation conditions; however, these types of records typically are notamenable to sub-annual interpretation due to their limited temporal resolution. Here wedeveloped a coral-based dust-wind proxy to overcome these temporal limitations by usingtrace (nmol/mol) rare earth elemental concentrations recorded in the skeletons of coralmicroatolls. The rare earth elements (REE; the lanthanides as well as scandium and yttrium)behave similarly in geologic and geochemical systems, and have served as useful proxies ofgeological processes in both deep and shallow time. Corals incorporate REE as they deposittheir exoskeletons that extend incrementally with time forming annual density band couplets.Coral microatolls grow at or near the sea surface, where coral REE concentrations are mostsensitive to dust deposition. Our study site off the west coast of Haiti is down stream of light-REE depleted bedrock whereas REE in African dust, transported by the easterly trade winds,reflect average crustal abundances. This unique "upstream" source signature allows forterrestrial contamination of the dust-wind signal to be ruled out. Light REE concentrations (esp.Nd and Pr) demonstrate an order of magnitude increase within coral aragonite coincident withmajor African dust plume events throughout the past decade, with Nd/Ca and Pr/Ca increasingfrom an average of 27 nmol/mol to an average 144 nmol/mol and an average of 5 nmol/mol toan average of 37 nmol/mol, respectively, during major African dust plume events. Monthly-resolved REE analysis shows these REE peaks coincide with the summer dust season rather thanHaiti's two wet seasons in spring and autumn. Regression of our coral REE dust proxy tosatellite records of African dust aerosol optical depth (AOD) provides a significant transferfunction [(REE)=3.00(AOD)-3.11, R 2 = 0.72, p ≤ 0.0005, df= 24]. Our results suggest coral REErecords have the potential to robustly reconstruct past African dust plume transport, thusproviding insight into the regional easterly trade wind patterns driving them.

  1. High concentrations of regional dust from deserts to plains across the central Rocky Mountains, USA

    NASA Astrophysics Data System (ADS)

    Reynolds, R. L.; Munson, S. M.; Fernandez, D. P.; Neff, J. C.

    2015-12-01

    Regional mineral dust in the American Southwest affects snow-melt rates, biogeochemical cycling, visibility, and public health. We measured total suspended particulates (TSP) across a 500-km-long sampling network of five remote sites in Utah and Colorado, USA, forming a gradient in distance from major dust emitting areas. The two westernmost sites on the Colorado Plateau desert had similar TSP concentrations (2008-2012, daily average=126 μg m-3; max. daily average over a two-week period=700 μg m-3 at Canyonlands National Park, Utah), while the easternmost High Plains site, close to cropped and grazed areas in northeastern Colorado, had an average concentration of 143 μg m-3 in 2011-2012 (max. daily average=656 μg m-3). Such concentrations rank comparably with those of TSP in several African and Asian cities in the paths of frequent dust storms. Dust loadings at the two intervening montane sites decreased from the western slope of the Rocky Mountains (Telluride, daily average=68 μg m-3) to an eastern site (Niwot Ridge, daily average=58 μg m-3). Back-trajectory analyses and satellite retrievals indicated that the three westernmost sites received most dust from large desert-source regions as far as 300 km to their southwest. These sources also sometimes sent dust to the two easternmost sites, which additionally captured dust from sources north and northwest of the central Rocky Mountains as well as locally at the Plains site. The PM10 fraction accounted for <15% of TSP, but most TSP is only slightly larger (typical median size, 15-20 μm) after about 100-800 km transport distances. Correlations between TSP and PM10 values indicate increases in both fractions during regional wind storms, especially related to Pacific frontal systems during late winter to late spring. These measurements and observations indicate that most dust deposition and associated air-quality problems in the interior American West are connected to regional dust sources and not to those in Asia.

  2. Soil respiration rates and δ13C(CO2) in natural beech forest (Fagus sylvatica L.) in relation to stand structure.

    PubMed

    Cater, Matjaz; Ogrinc, Nives

    2011-06-01

    Soil respiration rates were studied as a function of soil type, texture and light intensity at five selected natural beech forest stands with contrasting geology: stands on silicate bedrock at Kladje and Bricka in Pohorje, a stand on quartz sandstone at Vrhovo and two stands on a carbonate bedrock in the Karstic-Dinaric area in Kocevski Rog, Snezna jama and Rajhenav, Slovenia, during the growing season in 2005-2006. Soil respiration exhibited pronounced seasonal and spatial variations in the studied forest ecosystem plots. The CO(2) flux rates ranged from minimum averages of 2.3 μmol CO(2) m(-2) s(-1) (winter) to maximum averages of about 7 μmol CO(2) m(-2) s(-1) (summer) at all the investigated locations. An empirical model describing the relationship between soil respiration and soil temperature predicted seasonal variations in soil respiration reasonably well during 2006. Nevertheless, there were also some indications that soil moisture in relation to soil texture could influence the soil CO(2) efflux rates in both sampling seasons. It was shown that spatial variability of mean soil respiration at the investigated sites was high and strongly related to root biomass. Based on the [image omitted]  data, it was shown that new photoassimilates could account for a major part of the total soil respiration under canopy conditions in forest ecosystems where no carbonate rocks are present, indicating that microbial respiration could not always dominate bulk soil CO(2) fluxes. At Snezna jama and Rajhenav, the abiotic CO(2) derived from carbonate dissolution had a pronounced influence on CO(2) efflux accounting, on average, to ∼17%. Further spatial heterogeneity of soil respiration was clearly affected by management practice. Higher respiration rates as well as higher variability in respiration rates were observed in the virgin forest (Rajhenav) than in the management forest (Snezna jama) and could be related to a higher amount of detritus and consequently to less pronounced influence of inorganic pool to CO(2) efflux, lower mixing with atmospheric CO(2) and higher sensitivity to environmental changes. Major differences in soil carbon dynamics among these five forest ecosystems can be explained by the influence of bedrock geology (particularly, the presence or absence of carbonate minerals) and soil texture (affecting gas exchange with overlying air and soil moisture).

  3. Characterizing Particle Size Distributions of Crystalline Silica in Gold Mine Dust

    PubMed Central

    Chubb, Lauren G.; Cauda, Emanuele G.

    2017-01-01

    Dust containing crystalline silica is common in mining environments in the U.S. and around the world. The exposure to respirable crystalline silica remains an important occupational issue and it can lead to the development of silicosis and other respiratory diseases. Little has been done with regard to the characterization of the crystalline silica content of specific particle sizes of mine-generated dust. Such characterization could improve monitoring techniques and control technologies for crystalline silica, decreasing worker exposure to silica and preventing future incidence of silicosis. Three gold mine dust samples were aerosolized in a laboratory chamber. Particle size-specific samples were collected for gravimetric analysis and for quantification of silica using the Microorifice Uniform Deposit Impactor (MOUDI). Dust size distributions were characterized via aerodynamic and scanning mobility particle sizers (APS, SMPS) and gravimetrically via the MOUDI. Silica size distributions were constructed using gravimetric data from the MOUDI and proportional silica content corresponding to each size range of particles collected by the MOUDI, as determined via X-ray diffraction and infrared spectroscopic quantification of silica. Results indicate that silica does not comprise a uniform proportion of total dust across all particle sizes and that the size distributions of a given dust and its silica component are similar but not equivalent. Additional research characterizing the silica content of dusts from a variety of mine types and other occupational environments is necessary in order to ascertain trends that could be beneficial in developing better monitoring and control strategies. PMID:28217139

  4. Dust deposition and ambient PM10 concentration in northwest China: spatial and temporal variability

    NASA Astrophysics Data System (ADS)

    Zhang, Xiao-Xiao; Sharratt, Brenton; Chen, Xi; Wang, Zi-Fa; Liu, Lian-You; Guo, Yu-Hong; Li, Jie; Chen, Huan-Sheng; Yang, Wen-Yi

    2017-02-01

    Eolian dust transport and deposition are important geophysical processes which influence global bio-geochemical cycles. Currently, reliable deposition data are scarce in central and east Asia. Located at the boundary of central and east Asia, Xinjiang Province of northwestern China has long played a strategic role in cultural and economic trade between Asia and Europe. In this paper, we investigated the spatial distribution and temporal variation in dust deposition and ambient PM10 (particulate matter in aerodynamic diameter ≤ 10 µm) concentration from 2000 to 2013 in Xinjiang Province. This variation was assessed using environmental monitoring records from 14 stations in the province. Over the 14 years, annual average dust deposition across stations in the province ranged from 255.7 to 421.4 t km-2. Annual dust deposition was greater in southern Xinjiang (663.6 t km-2) than northern (147.8 t km-2) and eastern Xinjiang (194.9 t km-2). Annual average PM10 concentration across stations in the province varied from 100 to 196 µg m-3 and was 70, 115 and 239 µg m-3 in northern, eastern and southern Xinjiang, respectively. The highest annual dust deposition (1394.1 t km-2) and ambient PM10 concentration (352 µg m-3) were observed in Hotan, which is located in southern Xinjiang and at the southern boundary of the Taklamakan Desert. Dust deposition was more intense during the spring and summer than other seasons. PM10 was the main air pollutant that significantly influenced regional air quality. Annual average dust deposition increased logarithmically with ambient PM10 concentration (R2 ≥ 0.81). While the annual average dust storm frequency remained unchanged from 2000 to 2013, there was a positive relationship between dust storm days and dust deposition and PM10 concentration across stations. This study suggests that sand storms are a major factor affecting the temporal variability and spatial distribution of dust deposition in northwest China.

  5. A Multi-Year Dust Devil Vortex Survey Using an Automated Search of Pressure Time-Series

    NASA Astrophysics Data System (ADS)

    Jackson, Brian K.; Lorenz, Ralph

    2014-11-01

    Dust devils occur in arid climates on the Earth and ubiquitously on Mars, where they likely dominate the supply of atmospheric dust and influence climate. Martian dust devils have been studied with a combination of orbiting and landed spacecraft, while most studies of terrestrial dust devils have involved manned monitoring of field sites, which can be costly both in time and personnel. As an alternative approach, we describe a multi-year in-situ survey of terrestrial dust devils using pressure loggers deployed at El Dorado Playa in Nevada, USA, a site known for dust devil activity. Analogous to previous surveys for Martian dust devils, we conduct a post-hoc analysis of the barometric data to search for putative dust devil pressure dips using a new automated detection algorithm. We investigate the completeness and false positive rates of our new algorithm and conduct several statistically robust analyses of the resulting population of dips. We also investigate seasonal, annual, and spatial variability of the putative dust devil dips, possible correlations with precipitation, and the influence of sample size on the derived population statistics. Our results suggest that large numbers of dips (> 1,000) collected over multiple seasons are probably required for accurate assessment of the underlying dust devil population. Correlating long-term barometric time-series with other data streams (e.g., solar flux measurements from photovoltaic cells) can uniquely elucidate the natures and origins of dust devils, and accurately assessing their influence requires consideration of the full distribution of dust devil properties, rather than average values. For example, our results suggest the dust flux from the average terrestrial devil is nearly 1,000 times smaller than the (more representative) population-weighted average flux. If applicable to Martian dust devils, such corrections may help resolve purported discrepancies between the dust fluxes estimated from dust devil studies and those required to maintain the atmospheric dust concentration.

  6. Silica exposure and silicosis among Ontario hardrock miners: II. Exposure estimates.

    PubMed

    Verma, D K; Sebestyen, A; Julian, J A; Muir, D C; Schmidt, H; Bernholz, C D; Shannon, H S

    1989-01-01

    An epidemiological investigation was carried out to determine the relationship between silicosis in hardrock miners in Ontario and cumulative exposure to silica (free crystalline silica--alpha quartz) dust. This second report describes a side-by-side air-sampling program used to derive a konimeter/gravimetric silica conversion curve. A total of 2,360 filter samples and 90,000 konimeter samples were taken over 2 years in two mines representing the ore types gold and uranium, both in existing conditions as well as in an experimental stope in which dry drilling was used to simulate the high dust conditions of the past. The method of calculating cumulative respirable silica exposure indices for each miner is reported.

  7. A Brief Review of Silicosis in the United States

    PubMed Central

    Thomas, Carson R.; Kelley, Timothy R.

    2010-01-01

    Silicosis may be defined as the disease resulting from chronic occupational exposure to silica dust. Silica is primarily composed of quartz dust and has been classified since 2000 as a known human carcinogen by the U.S. government. Silicosis may lead to impairment of lung function resulting from fibrosis of the lungs. This may in turn lead to an increased susceptibility to the development of tuberculosis. Respirable particles are in the size range of less than one micrometer to as large as 30 micrometers. Silicosis is an untreatable, but preventable disease. This review explores the history of silicosis in the U.S. mining industry, including case studies of occupational silicosis. PMID:20523881

  8. Exposure to respirable crystalline silica in South African farm workers

    NASA Astrophysics Data System (ADS)

    Swanepoel, Andrew; Rees, David; Renton, Kevin; Kromhout, Hans

    2009-02-01

    Although listed in some publications as an activity associated with silica (quartz) exposure, agriculture is not widely recognized as an industry with a potential for silica associated diseases. Because so many people work in agriculture; and because silica exposure and silicosis are associated with serious diseases such as tuberculosis (TB), particular in those immunological compromised by the Human immunodeficiency virus (HIV), silica exposure in agriculture is potentially very important. But in South Africa (SA) very little is known about silica exposure in this industry. The objectives of this project are: (a) to measure inhalable and respirable dust and its quartz content on two typical sandy soil farms in the Free State province of SA for all major tasks done on the farms; and (b) to characterise the mineralogy soil type of these farms. Two typical farms in the sandy soil region of the Free State province were studied. The potential health effects faced by these farm workers from exposure to respirable crystalline silica are discussed.

  9. Cytotoxic effects of composite dust on human bronchial epithelial cells.

    PubMed

    Cokic, Stevan M; Hoet, Peter; Godderis, Lode; Wiemann, Martin; Asbach, Christof; Reichl, Franz X; De Munck, Jan; Van Meerbeek, Bart; Van Landuyt, Kirsten L

    2016-12-01

    Previous research revealed that during routine abrasive procedures like polishing, shaping or removing of composites, high amounts of respirable dust particles (<5μm) including nano-sized particles (<100nm) may be released. To determine the cytotoxic potential of composite dust particles on bronchial epithelium cells. Composite dust of five commercial composites (one nano-composite, two nano-hybrid and two hybrid composites) was generated following a clinically relevant protocol. Polymerized composite samples were cut with a rough diamond bur (grain size 100μm, speed 200,000rpm) and all composite dust was collected in a sterile chamber. Human bronchial epithelial cells (16HBE14o-) were exposed to serially diluted suspensions of composite dust in cell culture medium at concentrations between 1.1 and 3.3mg/ml. After 24h-exposure, cell viability and membrane integrity were assessed by the WST-1 and the LDH leakage assay, respectively. The release of IL-1β and IL-6 was evaluated. The composite dust particles were characterized by transmission electron microscopy and by dynamic and electrophoretic light scattering. Neither membrane damage nor release of IL-1β was detected over the complete concentration range. However, metabolic activity gradually declined for concentrations higher than 660μg/ml and the release of IL-6 was reduced when cells were exposed to the highest concentrations of dust. Composite dust prepared by conventional dental abrasion methods only affected human bronchial epithelial cells in very high concentrations. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  10. Direct-on-Filter α-Quartz Estimation in Respirable Coal Mine Dust Using Transmission Fourier Transform Infrared Spectrometry and Partial Least Squares Regression

    PubMed Central

    Miller, Arthur L.; Weakley, Andrew Todd; Griffiths, Peter R.; Cauda, Emanuele G.; Bayman, Sean

    2017-01-01

    In order to help reduce silicosis in miners, the National Institute for Occupational Health and Safety (NIOSH) is developing field-portable methods for measuring airborne respirable crystalline silica (RCS), specifically the polymorph α-quartz, in mine dusts. In this study we demonstrate the feasibility of end-of-shift measurement of α-quartz using a direct-on-filter (DoF) method to analyze coal mine dust samples deposited onto polyvinyl chloride filters. The DoF method is potentially amenable for on-site analyses, but deviates from the current regulatory determination of RCS for coal mines by eliminating two sample preparation steps: ashing the sampling filter and redepositing the ash prior to quantification by Fourier transform infrared (FT-IR) spectrometry. In this study, the FT-IR spectra of 66 coal dust samples from active mines were used, and the RCS was quantified by using: (1) an ordinary least squares (OLS) calibration approach that utilizes standard silica material as done in the Mine Safety and Health Administration's P7 method; and (2) a partial least squares (PLS) regression approach. Both were capable of accounting for kaolinite, which can confound the IR analysis of silica. The OLS method utilized analytical standards for silica calibration and kaolin correction, resulting in a good linear correlation with P7 results and minimal bias but with the accuracy limited by the presence of kaolinite. The PLS approach also produced predictions well-correlated to the P7 method, as well as better accuracy in RCS prediction, and no bias due to variable kaolinite mass. Besides decreased sensitivity to mineral or substrate confounders, PLS has the advantage that the analyst is not required to correct for the presence of kaolinite or background interferences related to the substrate, making the method potentially viable for automated RCS prediction in the field. This study demonstrated the efficacy of FT-IR transmission spectrometry for silica determination in coal mine dusts, using both OLS and PLS analyses, when kaolinite was present. PMID:27645724

  11. Direct-on-Filter α-Quartz Estimation in Respirable Coal Mine Dust Using Transmission Fourier Transform Infrared Spectrometry and Partial Least Squares Regression.

    PubMed

    Miller, Arthur L; Weakley, Andrew Todd; Griffiths, Peter R; Cauda, Emanuele G; Bayman, Sean

    2017-05-01

    In order to help reduce silicosis in miners, the National Institute for Occupational Health and Safety (NIOSH) is developing field-portable methods for measuring airborne respirable crystalline silica (RCS), specifically the polymorph α-quartz, in mine dusts. In this study we demonstrate the feasibility of end-of-shift measurement of α-quartz using a direct-on-filter (DoF) method to analyze coal mine dust samples deposited onto polyvinyl chloride filters. The DoF method is potentially amenable for on-site analyses, but deviates from the current regulatory determination of RCS for coal mines by eliminating two sample preparation steps: ashing the sampling filter and redepositing the ash prior to quantification by Fourier transform infrared (FT-IR) spectrometry. In this study, the FT-IR spectra of 66 coal dust samples from active mines were used, and the RCS was quantified by using: (1) an ordinary least squares (OLS) calibration approach that utilizes standard silica material as done in the Mine Safety and Health Administration's P7 method; and (2) a partial least squares (PLS) regression approach. Both were capable of accounting for kaolinite, which can confound the IR analysis of silica. The OLS method utilized analytical standards for silica calibration and kaolin correction, resulting in a good linear correlation with P7 results and minimal bias but with the accuracy limited by the presence of kaolinite. The PLS approach also produced predictions well-correlated to the P7 method, as well as better accuracy in RCS prediction, and no bias due to variable kaolinite mass. Besides decreased sensitivity to mineral or substrate confounders, PLS has the advantage that the analyst is not required to correct for the presence of kaolinite or background interferences related to the substrate, making the method potentially viable for automated RCS prediction in the field. This study demonstrated the efficacy of FT-IR transmission spectrometry for silica determination in coal mine dusts, using both OLS and PLS analyses, when kaolinite was present.

  12. Exposure to welding fumes is associated with hypomethylation of the F2RL3 gene: a cardiovascular disease marker.

    PubMed

    Hossain, Mohammad B; Li, Huiqi; Hedmer, Maria; Tinnerberg, Håkan; Albin, Maria; Broberg, Karin

    2015-12-01

    Welders are at risk for cardiovascular disease. Recent studies linked tobacco smoke exposure to hypomethylation of the F2RL3 (coagulation factor II (thrombin) receptor-like 3) gene, a marker for cardiovascular disease prognosis and mortality. However, whether welding fumes cause hypomethylation of F2RL3 remains unknown. We investigated 101 welders (median span of working as a welder: 7 years) and 127 unexposed controls (non-welders with no obvious exposure to respirable dust at work), age range 23-60 years, all currently non-smoking, in Sweden. The participants were interviewed about their work history, lifestyle factors and diseases. Personal sampling of respirable dust was performed for the welders. DNA methylation of F2RL3 in blood was assessed by pyrosequencing of four CpG sites, CpG_2 (corresponds to cg03636183) to CpG_5, in F2RL3. Multivariable linear regression analysis was used to assess the association between exposure to welding fumes and F2RL3 methylation. Welders had 2.6% lower methylation of CpG_5 than controls (p<0.001). Higher concentrations of measured respirable dust among the welders were associated with hypomethylation of CpG_2, CpG_4 and CpG_5 (β=-0.49 to -1.4, p<0.012); p<0.029 adjusted for age, previous smoking, passive smoking, education, current residence and respirator use. Increasing the number of years working as a welder was associated with hypomethylation of CpG_4 (linear regression analysis, β=-0.11, p=0.039, adjusted for previous smoking). Previous tobacco smokers had 1.5-4.7% (p<0.014) lower methylation of 3 of the 4 CpG sites in F2RL3 (CpG_2, CpG_4 and CpG_5) compared to never-smokers. A non-significant lower risk of cardiovascular disease with more methylation was observed for all CpG sites. Welding fumes exposure and previous smoking were associated with F2RL3 hypomethylation. This finding links low-to-moderate exposure to welding fumes to adverse effects on the cardiovascular system, and suggests a potential mechanistic pathway for this link, via epigenetic effects on F2RL3 expression. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. A comparative study of health risk of potentially toxic metals in urban and suburban road dust in the most populated city of China

    NASA Astrophysics Data System (ADS)

    Shi, Guitao; Chen, Zhenlou; Bi, Chunjuan; Wang, Li; Teng, Jiyan; Li, Yuansheng; Xu, Shiyuan

    2011-01-01

    Urban and suburban road dust samples were collected in the most populated city of China, Shanghai. Size fractions of dust particles were analyzed; metal levels of the dust were also measured. Human exposure to individual toxic metals through road dust was assessed for both children and adults. The results showed that dust particles from urban and suburban road were presented similar size distribution pattern, with most particles in the range of 100-400 μm. Urban road dust consisted of higher proportions of inhalable, thoracic and respirable particles with increased risk of adverse effects to human. In general, mean grain sizes of urban road dust were smaller than suburban dust. Total organic carbon contents and levels of Pb, Cd, Cu, Zn, Ni, Cr in urban dust were higher than those of suburban dust. But the concentrations of As and Hg from suburban dust were higher, indicting a different main source. The exposure pathway which resulted in the highest level of risk for human exposed to road dust was ingestion of this material, which was followed by dermal contact. Except for some locations, risk values of both cancer and non-cancer obtained in this study were in the receivable range on the whole. Children had greater health risks than adults. The overall risks of non-cancer in urban area were higher than those in suburban area, but the values of cancer in the two areas were comparable. As for the aggregate noncarcinogenic risk, Pb was of most concern regarding the potential occurrence of health impacts. Of the three carcinogenic metals As, Cr and Cd, the only mean risk higher than 10 -6 was Cr, accounting for a great percentage (95%) of the overall risk of cancer. Hence, potentially adverse health effects arising from Pb and Cr in road dust should arouse wide concern.

  14. [Health hazards resulting from exposure to zinc and its inorganic compounds in industry].

    PubMed

    Pakulska, Daria; Czerczak, Sławomir

    2017-10-17

    This article deals with health risks resulting from exposure to zinc and its inorganic compounds in industry. The main source of zinc exposure are fumes generated during thermal and chemical processes, mainly zinc oxide fume formed by immediate oxidation of metallic zinc vapor formed during high-temperature processes, as well as dust generated during the mechanical processing of zinc-containing materials. It is recognized that zinc ions are responsible for health effects of exposure to dust/fumes of the majority of zinc compounds, and the final effect of exposure depends on the degree of dispersion of dusts/fumes suspended in the air. Since the effects of exposure depends on the particle size, occupational exposure limits have began to be established separately for respirable and inhalable fractions. A critical effect of acute exposure to respirable fraction is a "fume fever" which in chronic exposure occurs as an effect associated with recurrent symptoms of acute poisoning. Impaired lung function and asthma symptoms are considered to be the main effects of exposure to inhalable fraction. Due to the limited number of the available data it is not possible to assess carcinogenicity, reproductive toxicity and teratogenicity of zinc and its compounds. The aim of the study was to analyze the major health hazards resulting from occupational exposure to zinc and its inorganic compounds in the context of their physico-chemical properties, a wide range of applications and occupational exposure data. Med Pr 2017;68(6):779-794. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  15. Risk Evaluation of Construction Workers' Exposure to Silica Dust and the Possible Lung Function Impairments.

    PubMed

    Tavakol, Elahe; Azari, Mansour; Zendehdel, Rezvan; Salehpour, Sousan; Khodakrim, Soheila; Nikoo, Saeed; Saranjam, Behzad

    2017-06-01

    Aerosols generated during construction activities are an integral part of building operations. Considering the nature of materials used in construction activities, respirable dust contains crystalline silica and particulates not otherwise specified (PNOS). Due to lack of data regarding the occupational health status of Iranian construction workers, the objective of this study was to evaluate occupational exposure to silica and to examine their respiratory health status. In this cross sectional study, 85 construction workers and 40 controls (without active exposure to construction dust) were studied. The workers' exposure to PNOS and silica aerosols was monitored by the NIOSH method No.0600 and a new Fourier transform infrared spectroscopy (FTIR)-based method, respectively. All subjects were also monitored for lung function parameters, such as forced expiratory volume/forced vital capacity (FEV 1 /FVC), peak expiratory flow rate (PEFR), forced expiratory flow (FEF 25-75 ), FVC, and FEV 1 . The mean exposure of workers to respirable PNOS and silica was 9.8 (0.35) and 0.13 (0.019) mg/m 3 , respectively. The groups of construction workers showed significant differences in exposure to PNOS ( P < 0.001) and silica ( P = 0.007). The mean pulmonary function parameters, including FEV 1 % and FVC%, were significantly lower among construction workers, compared to the control group ( P < 0.001 and P = 0.009, respectively). The pulmonary status of 51.8% of construction workers showed moderate restriction, while 4.70% exhibited obstruction. Considering the construction workers' excessive exposure to PNOS and silica, besides depressed lung function parameters, they can be classified as a high-risk group for respiratory diseases.

  16. Oxidative stress, telomere shortening, and DNA methylation in relation to low‐to‐moderate occupational exposure to welding fumes

    PubMed Central

    Li, Huiqi; Hedmer, Maria; Wojdacz, Tomasz; Hossain, Mohammad Bakhtiar; Lindh, Christian H.; Tinnerberg, Håkan; Albin, Maria

    2015-01-01

    Evidence suggests that exposure to welding fumes is a risk factor for lung cancer. We examined relationships between low‐to‐moderate occupational exposure to particles from welding fumes and cancer‐related biomarkers for oxidative stress, changes in telomere length, and alterations in DNA methylation. We enrolled 101 welders and 127 controls (all currently nonsmoking men) from southern Sweden. We performed personal sampling of respirable dust and measured 8‐oxodG concentrations in urine using a simplified liquid chromatography tandem mass spectrometry method. Telomere length in peripheral blood was measured by quantitative polymerase chain reaction. Methylation status of 10 tumor suppressor genes was determined by methylation‐sensitive high‐resolution melting analysis. All analyses were adjusted for age, body mass index, previous smoking, passive smoking, current residence, and wood burning stove/boiler at home. Welders were exposed to respirable dust at 1.2 mg/m3 (standard deviation, 3.3 mg/m3; range, 0.1–19.3), whereas control exposures did not exceed 0.1 mg/m3 (P < 0.001). Welders and controls did not differ in 8‐oxodG levels (β = 1.2, P = 0.17) or relative telomere length (β = −0.053, P = 0.083) in adjusted models. Welders showed higher probability of adenomatous polyposis coli (APC) methylation in the unadjusted model (odds ratio = 14, P = 0.014), but this was not significant in the fully adjusted model (P = 0.052). Every working year as a welder was associated with 0.0066 units shorter telomeres (95% confidence interval −0.013 to −0.00053, P = 0.033). Although there were no clear associations between concentrations of respirable dust and the biomarkers, there were modest signs of associations between oxidative stress, telomere alterations, DNA methylation, and occupational exposure to low‐to‐moderate levels of particles. Environ. Mol. Mutagen. 56:684–693, 2015. © 2015 The Authors. Environmental and Molecular Mutagenesis Published by Wiley Periodicals, Inc. PMID:26013103

  17. Naturally occurring diacetyl and 2,3-pentanedione concentrations associated with roasting and grinding unflavored coffee beans in a commercial setting.

    PubMed

    Gaffney, Shannon H; Abelmann, Anders; Pierce, Jennifer S; Glynn, Meghan E; Henshaw, John L; McCarthy, Lauren A; Lotter, Jason T; Liong, Monty; Finley, Brent L

    2015-01-01

    Over the last decade, concerns have been raised about potential respiratory health effects associated with occupational exposure to the flavoring additives diacetyl and 2,3-pentanedione. Both of these diketones are also natural components of many foods and beverages, including roasted coffee. To date, there are no published studies characterizing workplace exposures to these diketones during commercial roasting and grinding of unflavored coffee beans. In this study, we measured naturally occurring diacetyl, 2,3-pentanedione, and respirable dust at a facility that roasts and grinds coffee beans with no added flavoring agents. Sampling was conducted over the course of three roasting batches and three grinding batches at varying distances from a commercial roaster and grinder. The three batches consisted of lightly roasted soft beans, lightly roasted hard beans, and dark roasted hard beans. Roasting occurred for 37 to 41 min, and the grinding process took between 8 and 11 min. Diacetyl, 2,3-pentanedione, and respirable dust concentrations measured during roasting ranged from less than the limit of detection (

  18. Mortality of Sardinian lead and zinc miners: 1960-88.

    PubMed Central

    Cocco, P L; Carta, P; Belli, S; Picchiri, G F; Flore, M V

    1994-01-01

    The mortality of 4740 male workers of two lead and zinc mines was followed up from 1960 to 1988. Exposure to respirable dust was comparable in the two mines, but the median concentration of silica in respirable dust was 10-fold higher in mine B (12.8%) than in mine A (1.2%), but the mean annual exposure to radon daughters in underground workplaces differed in the opposite direction (mine A: 0.13 working levels (WL), mine B: 0.011 WL). Total observed deaths (1205) were similar to expected figures (1156.3) over a total of 119 390.5 person-years at risk. Underground workers of mine B had significant increases in risk of pulmonary tuberculosis (SMR 706, 95% confidence interval (95% CI) 473-1014) and non-malignant respiratory diseases (SMR 518; 95% CI 440-1606), whereas the only significant excess at mine A was for non-malignant respiratory diseases (SMR 246; 95% CI 191-312). Total cancer and lung cancer mortality did not exceed the expectation in the two mines combined. A 15% excess mortality for lung cancer, increased up to an SMR 204 (95% CI 89-470) for subjects employed > or = 26 years, was, however, found among underground workers in mine A who on the average experienced an exposure to radon daughters 10-fold higher than those of mine B. By contrast, despite their higher exposure to silica, mine B underground workers experienced a lower than expected lung cancer mortality. A ninefold increase in risk of peritoneal and retroperitoneal cancer combined was also found among underground workers of mine A (SMR 917; 95% CI 250-2347; based on four deaths). A causal association with workplace exposures is unlikely, however, as the SMR showed an inverse trend by duration of employment. These findings are consistent with low level exposure to radon daughters as a risk factor for lung cancer among metal miners. Exposure to silica at the levels estimated for the mine B underground environment did not increase the risk of lung cancer. PMID:8000492

  19. Net photosynthesis and respiration of sago pondweed (Potamogeton pectinatus) exposed to herbicides

    USGS Publications Warehouse

    Fleming, W.J.; Ailstock, M.S.; Momot, J.J.; Hughes, Jane S.; Biddinger, Gregory R.; Mones, Eugene

    1995-01-01

    We determined net photosynthesis and respiration rates for sago pondweed (potamogeton pectinatus) exposed to various concentrations of 11 herbicides widely used in Maryland during the past decade. Net photosynthesis and respiration were determined by measuring changes in the. oxygen content of solutions containing dilutions of technical grade herbicides. At 20-22? C and 58 umol/m2/sec of photosynthetically active radiation (PAR), oxygen production of undosed plants averaged 0.72-2.03 mg/g fresh wt/h. Respiration rates of undosed plants averaged 0.46-0.60 mg O2/g fresh wt/h. Nominal herbicide concentrations (ng/L) that reduced net photosynthesis by 5O percent (IC5O) were: metribuzin, 8; atrazine, 29; cyanazine, 32; linuron, 70; simazine, 164; and paraquat, 240. IC5O values for 2,4-D, acifluorfen, glyphosate and metolachlor exceeded the maximum test concentration of 10,000 ng/L. The IC5O value for alachlor was estimated to be between 1,000 and 10,000 ng/L. None of the herbicides tested had a significant effect on dark respiration.

  20. A Robust Apnea Period Detection Method in Changing Sleep Posture by Average Mutual Information of Heartbeat and Respiration

    NASA Astrophysics Data System (ADS)

    Kurihara, Yosuke; Watanabe, Kajiro; Kobayashi, Kazuyuki; Tanaka, Tanaka

    Sleep disorders disturb the recovery from mental and physical fatigues, one of the functions of the sleep. The majority of those who with the disorders are suffering from Sleep Apnea Syndrome (SAS). Continuous Hypoxia during sleep due to SAS cause Circulatory Disturbances, such as hypertension and ischemic heart disease, and Malfunction of Autonomic Nervous System, and other severe complications, often times bringing the suffers to death. In order to prevent these from happening, it is important to detect the SAS in its early stage by monitoring the daily respirations during sleep, and to provide appropriate treatments at medical institutions. In this paper, the Pneumatic Method to detect the Apnea period during sleep is proposed. Pneumatic method can measure heartbeat and respiration signal. Respiration signal can be considered as noise against heartbeat signal, and the decrease in the respiration signal due to Apnea increases the Average Mutual Information of heartbeat. The result of scaling analysis of the average mutual information is defined as threshold to detect the apnea period. The root mean square error between the lengths of Apnea measured by Strain Gauge using for reference and those measured by using the proposed method was 3.1 seconds. And, error of the number of apnea times judged by doctor and proposal method in OSAS patients was 3.3 times.

  1. Dust deposition in southern Nevada and California, 1984-1989: Relations to climate, source area, and source lithology

    NASA Astrophysics Data System (ADS)

    Reheis, Marith C.; Kihl, Rolf

    1995-05-01

    Dust samples collected annually for 5 years from 55 sites in southern Nevada and California provide the first regional source of information on modern rates of dust deposition, grain size, and mineralogical and chemical composition relative to climate and to type and lithology of dust source. The average silt and clay flux (rate of deposition) in southern Nevada and southeastern California ranges from 4.3 to 15.7 g/m2/yr, but in southwestern California the average silt and clay flux is as high as 30 g/m2/yr. The climatic factors that affect dust flux interact with each other and with the factors of source type (playas versus alluvium), source lithology, geographic area, and human disturbance. Average dust flux increases with mean annual temperature but is not correlated to decreases in mean annual precipitation because the regional winds bring dust to relatively wet areas. In contrast, annual dust flux mostly reflects changes in annual precipitation (relative drought) rather than temperature. Although playa and alluvial sources produce about the same amount of dust per unit area, the total volume of dust from the more extensive alluvial sources is much larger. In addition, playa and alluvial sources respond differently to annual changes in precipitation. Most playas produce dust that is richer in soluble salts and carbonate than that from alluvial sources (except carbonate-rich alluvium). Gypsum dust may be produced by the interaction of carbonate dust and anthropogenic or marine sulfates. The dust flux in an arid urbanizing area may be as much as twice that before disturbance but decreases when construction stops. The mineralogic and major-oxide composition of the dust samples indicates that sand and some silt is locally derived and deposited, whereas clay and some silt from different sources can be far-traveled. Dust deposited in the Transverse Ranges of California by the Santa Ana winds appears to be mainly derived from sources to the north and east.

  2. Evaluation of the SKC DPM cassette for monitoring diesel particulate matter in coal mines.

    PubMed

    Noll, James D; Birch, Eileen

    2004-12-01

    In a previous study, the efficacy of commercial and prototype impactors for sampling diesel particulate matter (DPM) in coal mines was investigated. Laboratory and field samples were collected on quartz-fiber filters and analyzed for organic and elemental carbon. Coal dust contributed a minimal amount of elemental carbon when commercial cascade impactors and prototype impactors, designed by the University of Minnesota (UMN) and the US Bureau of Mines (BOM), were used to collect submicrometer dust fractions. Other impactors were not as effective at excluding coal dust. The impactors evaluated in that study were either not commercially available or were multi-stage, expensive, and difficult to use for personal measurements. A commercial version of the BOM impactor, called the DPM Cassette, was recently introduced by SKC. Tests were conducted to evaluate the performance of the DPM Cassette for measuring diesel-source elemental carbon in the presence of coal dust. Bituminous coals from three mines in two different coal provinces were examined. The dust particle diameters were small and the coal dust contained a high percentage of carbon, thereby giving a worst-case condition for non-anthracite coal mines. Results for the DPM Cassette were essentially identical to those obtained by the BOM impactors in a previous study. At a respirable coal dust concentration of 5.46 mg m(-3), which is 3.8 times the regulatory limit, the DPM Cassette collected only 34 microg m(-3) of coal-source elemental carbon.

  3. Foam property tests to evaluate the potential for longwall shield dust control.

    PubMed

    Reed, W R; Beck, T W; Zheng, Y; Klima, S; Driscoll, J

    2018-01-01

    Tests were conducted to determine properties of four foam agents for their potential use in longwall mining dust control. Foam has been tried in underground mining in the past for dust control and is currently being reconsidered for use in underground coal longwall operations in order to help those operations comply with the Mine Safety and Health Administration's lower coal mine respirable dust standard of 1.5 mg/m 3 . Foams were generated using two different methods. One method used compressed air and water pressure to generate foam, while the other method used low-pressure air generated by a blower and water pressure using a foam generator developed by the U.S. National Institute for Occupational Safety and Health. Foam property tests, consisting of a foam expansion ratio test and a water drainage test, were conducted to classify foams. Compressed-air-generated foams tended to have low expansion ratios, from 10 to 19, with high water drainage. Blower-air-generated foams had higher foam expansion ratios, from 30 to 60, with lower water drainage. Foams produced within these ranges of expansion ratios are stable and potentially suitable for dust control. The test results eliminated two foam agents for future testing because they had poor expansion ratios. The remaining two foam agents seem to have properties adequate for dust control. These material property tests can be used to classify foams for their potential use in longwall mining dust control.

  4. Foam property tests to evaluate the potential for longwall shield dust control

    PubMed Central

    Reed, W.R.; Beck, T.W.; Zheng, Y.; Klima, S.; Driscoll, J.

    2018-01-01

    Tests were conducted to determine properties of four foam agents for their potential use in longwall mining dust control. Foam has been tried in underground mining in the past for dust control and is currently being reconsidered for use in underground coal longwall operations in order to help those operations comply with the Mine Safety and Health Administration’s lower coal mine respirable dust standard of 1.5 mg/m3. Foams were generated using two different methods. One method used compressed air and water pressure to generate foam, while the other method used low-pressure air generated by a blower and water pressure using a foam generator developed by the U.S. National Institute for Occupational Safety and Health. Foam property tests, consisting of a foam expansion ratio test and a water drainage test, were conducted to classify foams. Compressed-air-generated foams tended to have low expansion ratios, from 10 to 19, with high water drainage. Blower-air-generated foams had higher foam expansion ratios, from 30 to 60, with lower water drainage. Foams produced within these ranges of expansion ratios are stable and potentially suitable for dust control. The test results eliminated two foam agents for future testing because they had poor expansion ratios. The remaining two foam agents seem to have properties adequate for dust control. These material property tests can be used to classify foams for their potential use in longwall mining dust control. PMID:29416179

  5. Particle Size-Selective Assessment of Protection of European Standard FFP Respirators and Surgical Masks against Particles-Tested with Human Subjects

    PubMed Central

    Hwang, Dong-Chir; Li, He-Yi; Tsai, Chieh-Fu; Chen, Chun-Wan; Chen, Jen-Kun

    2016-01-01

    This study was conducted to investigate the protection of disposable filtering half-facepiece respirators of different grades against particles between 0.093 and 1.61 μm. A personal sampling system was used to particle size-selectively assess the protection of respirators. The results show that about 10.9% of FFP2 respirators and 28.2% of FFP3 respirators demonstrate assigned protection factors (APFs) below 10 and 20, which are the levels assigned for these respirators by the British Standard. On average, the protection factors of FFP respirators were 11.5 to 15.9 times greater than those of surgical masks. The minimum protection factors (PFs) were observed for particles between 0.263 and 0.384 μm. No significant difference in PF results was found among FFP respirator categories and particle size. A strong association between fit factors and protection factors was found. The study indicates that FFP respirators may not achieve the expected protection level and the APFs may need to be revised for these classes of respirators. PMID:27195721

  6. Characterization of air contaminants formed by the interaction of lava and sea water.

    PubMed

    Kullman, G J; Jones, W G; Cornwell, R J; Parker, J E

    1994-05-01

    We made environmental measurements to characterize contaminants generated when basaltic lava from Hawaii's Kilauea volcano enters sea water. This interaction of lava with sea water produces large clouds of mist (LAZE). Island winds occasionally directed the LAZE toward the adjacent village of Kalapana and the Hawaii Volcanos National Park, creating health concerns. Environmental samples were taken to measure airborne concentrations of respirable dust, crystalline silica and other mineral compounds, fibers, trace metals, inorganic acids, and organic and inorganic gases. The LAZE contained quantifiable concentrations of hydrochloric acid (HCl) and hydrofluoric acid (HF); HCl was predominant. HCl and HF concentrations were highest in dense plumes of LAZE near the sea. The HCl concentration at this sampling location averaged 7.1 ppm; this exceeds the current occupational exposure ceiling of 5 ppm. HF was detected in nearly half the samples, but all concentrations were <1 ppm Sulfur dioxide was detected in one of four short-term indicator tube samples at approximately 1.5 ppm. Airborne particulates were composed largely of chloride salts (predominantly sodium chloride). Crystalline silica concentrations were below detectable limits, less than approximately 0.03 mg/m3 of air. Settled dust samples showed a predominance of glass flakes and glass fibers. Airborne fibers were detected at quantifiable levels in 1 of 11 samples. These fibers were composed largely of hydrated calcium sulfate. These findings suggest that individuals should avoid concentrated plumes of LAZE near its origin to prevent over exposure to inorganic acids, specifically HCl.

  7. Long range transport of fine grained sediments on Mars: Atmospheric dust loading, as inferred from Viking Lander imaging data

    NASA Technical Reports Server (NTRS)

    Pollack, J. B.; Colburn, D. S.

    1984-01-01

    During the first Viking year, two global dust storms occurred and they contributed about 90% of the dust suspended in the Martian atmosphere on a global average, over the course of this year. The remainder was due to the cumulative effect of local dust storms. When globally distributed, the amount of suspended dust introduced into the atmosphere this Martian year was about 5x10(-3) g/sq cm. This mass loading was derived from the incremental optical depths measured over this year and estimates of the mean size of the dust particles (2.5 microns). During the second Martian year, global dust storms were far more muted than during the first year. No near perihelion dust storm occurred, and a somewhat weaker dust storm may have occurred near the start of the spring season in the Southern Hemisphere, at about the same time that the first global dust storm of the first year occurred. Thus, the dust loading derived for the first Martian year may be somewhat higher than the average over many Martian years, a conclusion that appears to be supported by preliminary studies of Martian years beyond the second Viking year on Mars.

  8. [Prevalence and risk factors of bronchial asthma among Li nationality in Hainan province].

    PubMed

    Ding, Yi-peng; Yao, Hong-xia; Tang, Xiao-lan; He, Hai-wu; Shi, Hui-fang; Lin, Li; Li, Min; Chen, Shan; Chen, Jing; Wang, Hai-jiao

    2011-02-01

    To study the risk factors of bronchial asthma of Li nationality in Hainan. A total of 13 050 subjects of Li nationality were selected by random unequal ratio stratified cluster sampling method from southern, central and western part of Hainan and investigated with Hainan Epidemiological Asthma Survey Questionnaire of Li Nationality. There were 441 cases of bronchial asthma, and 1296 cases of control that were sampled by random number table method. The logistic regression method was used to analyze risk factors. The asthma prevalence of Li nationality in Hainan was 3.38%(441/13 050). The main risk factors of asthma were family asthma (OR = 4.323, 95%CI = 3.259 - 5.735), hypersensitiveness (OR = 7.775, 95%CI = 5.686 - 10.632), smoking (OR = 1.494, 95%CI = 1.174 - 1.902), cooking fuels and living environment. Cold air change (OR = 1.604, 95%CI = 1.286 - 2.001) and respirable dust or irritant gas (OR = 2.123, 95%CI = 1.702 - 2.648) were the important incentives. The main risk factors of asthma among Li nationality were family asthma, hypersensitiveness, smoking, cooking fuels by means of fuel oil, hay or wood, living environment by means of couch grass room and human-livestock mix live, cold air change, respirable dust or irritant gas.

  9. Pulmonary epithelial response in the rat lung to instilled Montserrat respirable dusts and their major mineral components.

    PubMed

    Housley, D G; Bérubé, K A; Jones, T P; Anderson, S; Pooley, F D; Richards, R J

    2002-07-01

    The Soufriere Hills, a stratovolcano on Montserrat, started erupting in July 1995, producing volcanic ash, both from dome collapse pyroclastic flows and phreatic explosions. The eruptions/ash resuspension result in high concentrations of suspended particulate matter in the atmosphere, which includes cristobalite, a mineral implicated in respiratory disorders. To conduct toxicological studies on characterised samples of ash, together with major components of the dust mixture (anorthite, cristobalite), and a bioreactive mineral control (DQ12 quartz). Rats were challenged with a single mass (1 mg) dose of particles via intratracheal instillation and groups sacrificed at one, three, and nine weeks. Acute bioreactivity of the particles was assessed by increases in lung permeability and inflammation, changes in epithelial cell markers, and increase in the size of bronchothoracic lymph nodes. Data indicated that respirable ash derived from pyroclastic flows (20.1% cristobalite) or phreatic explosion (8.6% cristobalite) had minimal bioreactivity in the lung. Anorthite showed low bioreactivity, in contrast to pure cristobalite, which showed progressive increases in lung damage. Results suggests that either the percentage mass of cristobalite particles present in Montserrat ash was not sufficient as a catalyst in the lung environment, or its surface reactivity was masked by the non-reactive volcanic glass components during the process of ash formation.

  10. Bentonite toxicology and epidemiology - a review.

    PubMed

    Maxim, L Daniel; Niebo, Ron; McConnell, Ernest E

    2016-11-01

    Bentonite, a clay with numerous industrial and consumer applications, is mined and processed in many countries of the world. Its many beneficial uses also create the potential for widespread occupational and consumer exposure. The available studies on toxicity and epidemiology indicate that the principal exposure pathway of concern is inhalation of respirable dust by occupationally exposed cohorts. Bentonite itself is probably not more toxic than any other particulate not otherwise regulated and is not classified as a carcinogen by any regulatory or advisory body, but some bentonite may contain variable amounts of respirable crystalline silica, a recognized human carcinogen. Therefore, prudent management and adherence to occupational exposure limits is appropriate. This review summarizes the literature available on production, applications, exposure, toxicity, and epidemiology of bentonite and identifies data gaps and limitations.

  11. Relationship between chicken cellular immunity and endotoxin levels in dust from chicken housing environments

    PubMed Central

    Roque, Katharine; Shin, Kyung-Min; Jo, Ji-Hoon; Kim, Hyoung-Ah

    2015-01-01

    Hazardous biochemical agents in animal husbandry indoor environments are known to promote the occurrence of various illnesses among workers and animals. The relationship between endotoxin levels in dust collected from chicken farms and various immunological markers was investigated. Peripheral blood was obtained from 20 broiler chickens and 20 laying hens from four different chicken farms in Korea. Concentrations of total or respirable dust in the inside the chicken farm buildings were measured using a polyvinyl chloride membrane filter and mini volume sampler. Endotoxin levels in the dust were determined by the Limulus Amebocyte Lysate Kinetic method. Interferon-γ production by peripheral blood mononuclear cells stimulated with concanavalin A was significantly lower in broilers or layers from the farms with higher endotoxin concentrations than the chickens from the farms with lower endotoxin levels. An opposite pattern was observed for plasma cortisol concentrations with higher cortisol levels found in chickens from the farms with higher endotoxin levels. When peripheral lymphocytes were examined, the percentage of CD3-Ia+ B cells was lower in layers from farms with higher endotoxin levels than those from locations with lower endotoxin levels. Overall, these results suggest a probable negative association between dust endotoxin levels and cell-mediated immunity in chickens. PMID:25549222

  12. Numerical simulation of migration behavior of uranium ore dust particles in the human respiratory tract

    NASA Astrophysics Data System (ADS)

    Ye, Yong-jun; Yin, An-song; Li, Zhi; Lei, Bo; Ding, De-xin

    2017-04-01

    There is a certain concentration of radioactive dust particles in the air of workplace of underground uranium mines. Some small diameter particles will pass through the masks and enter the respiratory tract which will cause radiation damage to the human body. In order to study deposition regularity of uranium dust in the human respiratory tract, in this paper, we firstly use the RNG turbulence model to simulate the gas flow field in the human respiratory tract Z0 ∼ Z3 level under different respiratory intensity. Then we use DPM discrete phase model to simulate the concentration, particle size distribution, deposition rate and deposition share of uranium dust particles after being filtered through the masks in the human respiratory tract Z0 to Z3 bronchus. According to the simulation results, we have got the following conclusions: the particles’ number concentration of uranium dust after being filtered through the mask in the human respiratory tract basically decreases with the increasing of particle size under different respiratory intensities on the environment of uranium mine. In addition, the intensity of respiration and the mass concentration of particles have an important influence on the deposition rate and the deposition of particles in the respiratory tract.

  13. Environmental and medical study of byssinosis and other respiratory conditions in the cotton textile industry in Egypt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noweir, M.H.; Noweir, K.H.; Osman, H.A.

    1984-01-01

    This study was conducted in a typical Egyptian textile plant located in Alexandria. Male workers from all operations (N . 506) were examined and their dust exposures were assessed. Results showed that airborne dust concentrations were very high and that the plant fraction is mostly concentrated in respirable dust. Byssinosis prevailed in 21% of workers in opening and cleaning sections and in 13% in carding and combing rooms, but was found in none of the workers in drawing, twisting, and spinning operations, in only 1.1% in weaving, and in 3.1% of workers in other ''auxiliary'' occupations. The rare prevalence ofmore » byssinosis among the latter workers groups was attributed to the workers continuous exposure without fixed weekend interruption, the personal and family history of exposure to cotton, the low proportion of plant materials in dust evolved in related operations, the fine quality of Egyptian cotton, and/or the population characteristics of Egyptian workers. Reduction in FEV 1.0 at the end of the first work shift after absence from work occured more often than byssinosis, which indicates the importance of this test for the early detection of effects of cotton dust exposure. It is suggested that a nationwide study in the cotton textile industry is indicated.« less

  14. An assessment of hopanes in settled dust and air as indicators of exposure to traffic-related air pollution in Windsor, Ontario

    NASA Astrophysics Data System (ADS)

    Curran, Jason

    Traffic-related air pollution (TRAP) has been linked with several adverse health effects. We investigated hopanes, markers of primary particle emissions from gasoline and diesel engines, in house dust as an alternative approach for assessing exposure to TRAP in Windsor, Ontario. Settled house dust was collected from the homes of 28 study participants (10 -- 13 yrs). The dust was then analyzed for a suite of hopanes by gas chromatography-mass spectrometry. We calculated correlations between dust hopane concentrations and estimates of annual average NO2 concentrations derived from an existing LUR model. Hopanes were consistently present in detectable quantities in house dust. Annual average outdoor NO2 estimated was moderately correlated with hopanes in house dust (r = 0.46; p<0.05). The correlations did not vary by infiltration efficiency or the presence of an attached garage. Hopanes measured in settled house dust show promise as an indicator of long-term exposure to traffic-related air pollution. Keywords: hopane; air pollution; traffic; dust; exposure; TRAP.

  15. Macromolecular Rate Theory (MMRT) Provides a Thermodynamics Rationale to Underpin the Convergent Temperature Response in Plant Leaf Respiration

    NASA Astrophysics Data System (ADS)

    Liang, L. L.; Arcus, V. L.; Heskel, M.; O'Sullivan, O. S.; Weerasinghe, L. K.; Creek, D.; Egerton, J. J. G.; Tjoelker, M. G.; Atkin, O. K.; Schipper, L. A.

    2017-12-01

    Temperature is a crucial factor in determining the rates of ecosystem processes such as leaf respiration (R) - the flux of plant respired carbon dioxide (CO2) from leaves to the atmosphere. Generally, respiration rate increases exponentially with temperature as modelled by the Arrhenius equation, but a recent study (Heskel et al., 2016) showed a universally convergent temperature response of R using an empirical exponential/polynomial model whereby the exponent in the Arrhenius model is replaced by a quadratic function of temperature. The exponential/polynomial model has been used elsewhere to describe shoot respiration and plant respiration. What are the principles that underlie these empirical observations? Here, we demonstrate that macromolecular rate theory (MMRT), based on transition state theory for chemical kinetics, is equivalent to the exponential/polynomial model. We re-analyse the data from Heskel et al. 2016 using MMRT to show this equivalence and thus, provide an explanation based on thermodynamics, for the convergent temperature response of R. Using statistical tools, we also show the equivalent explanatory power of MMRT when compared to the exponential/polynomial model and the superiority of both of these models over the Arrhenius function. Three meaningful parameters emerge from MMRT analysis: the temperature at which the rate of respiration is maximum (the so called optimum temperature, Topt), the temperature at which the respiration rate is most sensitive to changes in temperature (the inflection temperature, Tinf) and the overall curvature of the log(rate) versus temperature plot (the so called change in heat capacity for the system, ). The latter term originates from the change in heat capacity between an enzyme-substrate complex and an enzyme transition state complex in enzyme-catalysed metabolic reactions. From MMRT, we find the average Topt and Tinf of R are 67.0±1.2 °C and 41.4±0.7 °C across global sites. The average curvature (average negative) is -1.2±0.1 kJ.mol-1K-1. MMRT extends the classic transition state theory to enzyme-catalysed reactions and scales up to more complex processes including micro-organism growth rates and ecosystem processes.

  16. The moisture response of soil heterotrophic respiration: Interaction with soil properties.

    USDA-ARS?s Scientific Manuscript database

    Soil moisture-respiration functions are used to simulate the various mechanisms determining the relations between soil moisture content and carbon mineralization. Soil models used in the simulation of global carbon fluxes often apply simplified functions assumed to represent an average moisture-resp...

  17. Lead isotopes and trace metals in dust at Yucca Mountain

    USGS Publications Warehouse

    Kwak, Loretta; Neymark, Leonid A.; Peterman, Zell E.

    2008-01-01

    Lead (Pb)-isotope compositions and trace-metal concentrations were determined for samples of dust collected from underground and surface locations at and near the proposed radioactive waste repository at Yucca Mountain, Nevada. Rare earth element concentrations in the dust samples from the underground tunnels are similar to those in wholerock samples of the repository host rocks (Miocene Tiva Canyon Tuff and Topopah Spring Tuff), supporting interpretation that the subsurface dust is mainly composed of rock comminuted during tunnel construction. Other trace metals (arsenic, cadmium, cobalt, chromium, copper, manganese, nickel, lead, antimony, thallium, and zinc) are variably enriched in the subsurface dust samples relative to the average concentrations in the host rocks. Average concentrations of arsenic and lead in dust samples, high concentrations of which can cause corrosion of waste canisters, have enrichment factors from 1.2 to 1.6 and are insignificant relative to the range of concentrations for these metals observed in the host rock samples. Most dust samples from surface sites also are enriched in many of these trace metals relative to average repository host rocks. At least some of these enrichments may be artifacts of sampling. Plotted on a 208Pb/206Pb-207Pb/206Pb graph, Pb-isotope compositions of dust samples from underground sites form a mixing line extending from host-rock Pb-isotope compositions towards compositions of many of the dust samples from surface sites; however, combined Pb concentration and isotope data indicate the presence of a Pbenriched component in the subsurface dust that is not derived from host rock or surface dust and may derive from anthropogenic materials introduced into the underground environment.

  18. Velocity-amplified microbial respiration rates in the lower Amazon River

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, Nicholas D.; Sawakuchi, Henrique O.; Neu, Va

    2018-01-31

    Most measurements of respiration rates in large tropical rivers do not account for the influence of river flow conditions on microbial activity. We developed a ship-board spinning incubation system for measuring O2 drawdown under different rotation velocities and deployed the system along the lower Amazon River during four hydrologic periods. Average respiration rates in incubation chambers rotated at 0.22 and 0.66 m s-1 were 1.4 and 2.4 times higher than stationary chambers, respectively. On average, depth-integrated respiration rates in chambers spun at 0.22 and 0.66 m s-1 accounted for 64 ± 22% and 104 ± 36% of CO2 outgassing rates,more » respectively, in mainstem sites. Continuous measurements of in situ pCO2 were also made along with cross-channel profiles of river velocity. A positive correlation between river velocity and pCO2 was observed along the lower river (r2=0.67-0.96) and throughout a tidal cycle.« less

  19. Integration of CO2 flux and remotely-sensed data for primary production and ecosystem respiration analyses in the Northern Great Plains: potential for quantitative spatial extrapolation

    USGS Publications Warehouse

    Gilmanov, Tagir G.; Tieszen, Larry L.; Wylie, Bruce K.; Flanagan, Larry B.; Frank, Albert B.; Haferkamp, Marshall R.; Meyers, Tilden P.; Morgan, Jack A.

    2005-01-01

    Aim  Extrapolation of tower CO2 fluxes will be greatly facilitated if robust relationships between flux components and remotely sensed factors are established. Long-term measurements at five Northern Great Plains locations were used to obtain relationships between CO2fluxes and photosynthetically active radiation (Q), other on-site factors, and Normalized Difference Vegetation Index (NDVI) from the SPOT VEGETATION data set. Location  CO2 flux data from the following stations and years were analysed: Lethbridge, Alberta 1998–2001; Fort Peck, MT 2000, 2002; Miles City, MT 2000–01; Mandan, ND 1999–2001; and Cheyenne, WY 1997–98. Results  Analyses based on light-response functions allowed partitioning net CO2 flux (F) into gross primary productivity (Pg) and ecosystem respiration (Re). Weekly averages of daytime respiration, γday, estimated from light responses were closely correlated with weekly averages of measured night-time respiration, γnight (R2 0.64 to 0.95). Daytime respiration tended to be higher than night-time respiration, and regressions of γday on γnight for all sites were different from 1 : 1 relationships. Over 13 site-years, gross primary production varied from 459 to 2491 g CO2 m−2 year−1, ecosystem respiration from 996 to 1881 g CO2 m−2 year−1, and net ecosystem exchange from −537 (source) to +610 g CO2 m−2 year−1 (sink). Maximum daily ecological light-use efficiencies, ɛd,max = Pg/Q, were in the range 0.014 to 0.032 mol CO2 (mol incident quanta)−1. Main conclusions  Ten-day average Pg was significantly more highly correlated with NDVI than 10-day average daytime flux, Pd (R2 = 0.46 to 0.77 for Pg-NDVI and 0.05 to 0.58 for Pd-NDVI relationships). Ten-day average Re was also positively correlated with NDVI, with R2values from 0.57 to 0.77. Patterns of the relationships of Pg and Re with NDVI and other factors indicate possibilities for establishing multivariate functions allowing scaling-up local fluxes to larger areas using GIS data, temporal NDVI, and other factors.

  20. Non-exhaust emission measurement system of the mobile laboratory SNIFFER

    NASA Astrophysics Data System (ADS)

    Pirjola, L.; Kupiainen, K. J.; Perhoniemi, P.; Tervahattu, H.; Vesala, H.

    In this paper we describe and quality assure the sampling system of a mobile research laboratory SNIFFER which was shown to be a useful tool for studying emission levels of respirable dust from street surfaces. The dust plume had bimodal structure; another mode rising to higher altitudes whereas the other mode remained at lower altitudes. The system was tested on a route in Helsinki, Finland, during spring 2005 and 2006. The PM 2.5 and PM 10 were positively correlated and the PM levels increased with the vehicle speed. SNIFFER was able to identify the characteristic emission levels on different streets. A clear downward trend in the concentrations was observed in all street locations between April and June. The composition of the street dust collected by SNIFFER was compared with springtime PM 10 aerosol samples from the air quality monitoring stations in Helsinki. The results showed similarities in the abundance and composition of the mineral fraction but contained significantly more salt particles.

  1. Global Gene Expression Profiling in Lung Tissues of Rat Exposed to Lunar Dust Particles

    NASA Technical Reports Server (NTRS)

    Yeshitla, Samrawit A.; Lam, Chiu-Wing; Kidane, Yared H.; Feiveson, Alan H.; Ploutz-Snyder, Robert; Wu, Honglu; James, John T.; Meyers, Valerie E.; Zhang, Ye

    2014-01-01

    The Moon's surface is covered by a layer of fine, potential reactive dust. Lunar dust contain about 1-2% respirable very fine dust (less than 3 micrometers). The habitable area of any lunar landing vehicle and outpost would inevitably be contaminated with lunar dust that could pose a health risk. The purpose of the study is to analyze the dynamics of global gene expression changes in lung tissues of rats exposed to lunar dust particles. F344 rats were exposed for 4 weeks (6h/d; 5d/wk) in nose-only inhalation chambers to concentrations of 0 (control air), 2.1, 6.8, 21, and 61 mg/m3 of lunar dust. Animals were euthanized at 1 day and 13 weeks after the last inhalation exposure. After being lavaged, lung tissue from each animal was collected and total RNA was isolated. Four samples of each dose group were analyzed using Agilent Rat GE v3 microarray to profile global gene expression of 44K transcripts. After background subtraction, normalization, and log transformation, t tests were used to compare the mean expression levels of each exposed group to the control group. Correction for multiple testing was made using the method of Benjamini, Krieger, and Yekuteli (1) to control the false discovery rate. Genes with significant changes of at least 1.75 fold were identified as genes of interest. Both low and high doses of lunar dust caused dramatic, dose-dependent global gene expression changes in the lung tissues. However, the responses of lung tissue to low dose lunar dust are distinguished from those of high doses, especially those associated with 61mg/m3 dust exposure. The data were further integrated into the Ingenuity system to analyze the gene ontology (GO), pathway distribution and putative upstream regulators and gene targets. Multiple pathways, functions, and upstream regulators have been identified in response to lunar dust induced damage in the lung tissue.

  2. Airborne manganese as dust vs. fume determining blood levels in workers at a manganese alloy production plant

    PubMed Central

    Park, Robert M.; Baldwin, Mary; Bouchard, Maryse F.; Mergler, Donna

    2015-01-01

    The appropriate exposure metrics for characterizing manganese (Mn) exposure associated with neurobehavioral effects have not been established. Blood levels of Mn (B-Mn) provide a potentially important intermediate marker of Mn airborne exposures. Using data from a study of a population of silicon- and ferro-manganese alloy production workers employed between 1973 and 1991, B-Mn levels were modeled in relation to prior Mn exposure using detailed work histories and estimated respirable Mn concentrations from air-sampling records. Despite wide variation in exposure levels estimated for individual jobs, duration of employment (exposure) was itself a strong predictor of B-Mn levels and strongest when an 80-day half-life was applied to contributions over time (t = 6.95, 7.44, respectively; p < 10 −5). Partitioning exposure concentrations based on process origin into two categories: (1) “large” respirable particulate (Mn-LRP) derived mainly from mechanically generated dust, and (2) “small” respirable particulate (Mn-SRP) primarily electric furnace condensation fume, revealed that B-Mn levels largely track the small, fume exposures. With a half-life of 65 days applied in a model with cumulative exposure terms for both Mn-LRP (t = −0.16, p = 0.87) and Mn-SRP (t = 6.45, p < 10 −5), the contribution of the large-size fraction contribution was negligible. Constructing metrics based on the square root of SRP exposure concentrations produced a better model fit (t = 7.87 vs. 7.44, R2 = 0.2333 vs. 0.2157). In a model containing both duration (t = 0.79, p = 0.43) and (square root) fume (t = 2.47, p = 0.01) metrics, the duration term was a weak contributor. Furnace-derived, small respirable Mn particulate appears to be the primary contributor to B-Mn levels, with a dose-rate dependence in a population chronically exposed to Mn, with air-concentrations declining in recent years. These observations may reflect the presence of homeostatic control of Mn levels in the blood and other body tissues and be useful in assessing Mn exposures for evaluating neurotoxic effects. PMID:24726792

  3. Diffusion in biofilms respiring on electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renslow, Ryan S.; Babauta, Jerome T.; Majors, Paul D.

    2012-11-15

    The goal of this study was to measure spatially and temporally resolved effective diffusion coefficients (De) in biofilms respiring on electrodes. Two model electrochemically active biofilms, Geobacter sulfurreducens PCA and Shewanella oneidensis MR-1, were investigated. A novel nuclear magnetic resonance microimaging perfusion probe capable of simultaneous electrochemical and pulsed-field gradient nuclear magnetic resonance (PFG-NMR) techniques was used. PFG-NMR allowed for noninvasive, nondestructive, high spatial resolution in situ De measurements in living biofilms respiring on electrodes. The electrodes were polarized so that they would act as the sole terminal electron acceptor for microbial metabolism. We present our results as both two-dimensionalmore » De heat maps and surface-averaged relative effective diffusion coefficient (Drs) depth profiles. We found that (1) Drs decreases with depth in G. sulfurreducens biofilms, following a sigmoid shape; (2) Drs at a given location decreases with G. sulfurreducens biofilm age; (3) average De and Drs profiles in G. sulfurreducens biofilms are lower than those in S. oneidensis biofilms—the G. sulfurreducens biofilms studied here were on average 10 times denser than the S. oneidensis biofilms; and (4) halting the respiration of a G. sulfurreducens biofilm decreases the De values. Density, reflected by De, plays a major role in the extracellular electron transfer strategies of electrochemically active biofilms.« less

  4. Motion of dust in a planetary magnetosphere - Orbit-averaged equations for oblateness, electromagnetic, and radiation forces with application to Saturn's E ring

    NASA Technical Reports Server (NTRS)

    Hamilton, Douglas P.

    1993-01-01

    The orbital dynamics of micrometer-sized dust grains is explored numerically and analytically, treating the strongest perturbation forces acting on close circumplanetary dust grains: higher-order gravity, radiation pressure, and the electromagnetic force. The appropriate orbit-average equations are derived and applied to the E ring. Arguments are made for the existence of azimuthal and vertical asymmetries in the E ring. New understanding of the dynamics of E ring dust grains is applied to problems of the ring's breadth and height. The possibility for further ground-based and spacecraft observations is considered.

  5. Radon Monitoring in Army Stand-Alone Housing Units

    DTIC Science & Technology

    1990-04-01

    greater damage to tissues. The internal exposures to alpha radiation resulting from inhalation of radioactive radon daughters (adsorbed onto airborne...appropriate detector, the monitor can measure all or some of the radon daughters adsorbed onto airborne, respirable dust particles. As with the 3...input to the cell is equipped with a 0.8-rim micropore filter that3removes any solid radon daughters from the air stream. Alpha I 26 Final Report, April

  6. Respirator Qualitative/Quantitative Fit Test Method Analysis

    DTIC Science & Technology

    1980-08-01

    carefully fitted to sample the atmosphere in the oral/ nasal or visual cavity. Leakage is expressed as a ratio of the ambient challenge atmosphere...8, 10, 40, 205, 274). While cer- Lain counercial polymer films have reportedly caused fibrosarcomas and other tumors in rats, this has been attributed... nasal passages (Portland cement dust), or cause injury to the skin or mucous membranes by chemical or mechanical action per se or by the rigorous skin

  7. Concentrations and emission rates of aerial ammonia, nitrous oxide, methane, carbon dioxide, dust and endotoxin in UK broiler and layer houses.

    PubMed

    Wathes, C M; Holden, M R; Sneath, R W; White, R P; Phillips, V R

    1997-03-01

    1. A survey of the concentration and emission rates of aerial ammonia, nitrous oxide, methane, carbon dioxide, dust and endotoxin was undertaken in 4 examples each of typical UK broiler, cage and perchery houses over 24 h during winter and summer. 2. Overall the air quality within the poultry houses was unsatisfactory as judged by the dual criteria of farmer health and bird performance. 3. Mean concentrations of ammonia ranged from 12.3 to 24.2 ppm while concentrations of methane and nitrous oxide were close to ambient levels. Mass concentrations of aerial dust ranged from 2 to 10 mg/m3 and 0.3 to 1.2 mg/m3 for inspirable and respirable fractions respectively, while endotoxin concentration was typically about 0.1 microgram/m3 (inspirable fraction). 4. Emission rates of gaseous ammonia were rapid (9.2 g (NH3)/h per 500 kg live body weight) and uniform across the three types of building, while emissions of methane and nitrous oxide were slow. Rates of dust emission ranged from 0.86 to 8.24 g/h per 500 kg live body weight in the inspirable size fraction.

  8. Work-related symptoms and dose-response relationships for personal exposures and pulmonary function among woodworkers.

    PubMed

    Mandryk, J; Alwis, K U; Hocking, A D

    1999-05-01

    Four sawmills, a wood chipping mill, and five joineries in New South Wales, Australia, were studied for the effects of personal exposure to wood dust, endotoxins. (1-->3)-beta-D-glucans, Gram-negative bacteria, and fungi on lung function among woodworkers. Personal inhalable and respirable dust sampling was carried out. The lung function tests of workers were conducted before and after a workshift. The mean percentage cross-shift decrease in lung function was markedly high for woodworkers compared with the controls. Dose-response relationships among personal exposures and percentage cross-shift decrease in lung function and percentage predicted lung function were more pronounced among joinery workers compared with sawmill and chip mill workers. Woodworkers had markedly high prevalence of regular cough, phlegm, and chronic bronchitis compared with controls. Significant associations were found between percentage cross-shift decrease in FVC and regular phlegm and blocked nose among sawmill and chip mill workers. Both joinery workers and sawmill and chip mill workers showed significant relationships between percentage predicted lung function (FVC, FEV1, FEV1/FVC, FEF25-75%) and respiratory symptoms. Wood dust and biohazards associated with wood dust are potential health hazards and should be controlled.

  9. Quantifying the Interannual Variability in Global Carbon Fluxes from Heterotrophic Respiration using a Testbed and Pulse Response Modeling Approach.

    NASA Astrophysics Data System (ADS)

    Basile, S.; Wieder, W. R.; Hartman, M. D.; Keppel-Aleks, G.

    2017-12-01

    The atmospheric growth rate of carbon dioxide (CO2) varies interannually and is strongly correlated with climate factors, including temperature and drought. These climate drivers affect vegetation productivity and the rate of respiration of organic matter to CO2 (heterotrophic respiration). Here we quantified the interannual variability in global carbon fluxes from heterotrophic respiration and their relationship to climate drivers. We used a novel testbed approach to simulate respiration, then simulated the imprint that these modeled heterotrophic fluxes have on atmospheric CO2 using an idealized pulse response model. Two of the testbed formulations (MIMICS and CORPSE) are microbially explicit by incorporation of microbial physiological tradeoffs and microbial activity in soil near fine roots (rhizosphere soils), respectively, while the third model (CASA) uses a CENTURY-like microbially implicit framework. Modeled respiration exhibited subtle differences, with MIMICS showing the largest seasonal amplitude in the Northern Hemisphere and the strongest correlation with global temperature variations. At Mauna Loa (MLO) the simulated seasonal CO2 amplitude in response to global heterotrophic respiration ranged by a factor of 1.5 across the models with the MIMICS and CASA models producing the higher amplitude responses between 1987 and 2006. The seasonal CO2 amplitude at MLO varied by about 5% interannually, with the largest variation in the MIMICS model. In the Northern Hemisphere there was a similar response range in average peak-to-trough seasonal CO2 but all models showed slightly higher amplitude values. Comparatively in the Northern Hemisphere, the average seasonal CO2 amplitude in response to respiration ranged between 30%-41% of the seasonal CO2 amplitude in response to net primary productivity. We expect that exploring the imprint of heterotrophic respiration on atmospheric CO2 from these three different models will improve our understanding of the imprint that heterotrophic respiration imparts on atmospheric data. The aim of this work is to ultimately yield an approach for combining CO2 observations with remote sensing-based observations of terrestrial productivity to produce regional constraints on heterotrophic respiration.

  10. [Influence of traffic restriction on road and construction fugitive dust].

    PubMed

    Tian, Gang; Li, Gang; Qin, Jian-Ping; Fan, Shou-Bin; Huang, Yu-Hu; Nie, Lei

    2009-05-15

    By monitoring the road and construction dust fall continuously during the "Good Luck Beijing" sport events, the reduction of road and construction dust fall caused by traffic restriction was studied. The contribution rate of road and construction dust to particulate matter of Beijing atmosphere environment, and the emission ratio of it to total local PM10 emission were analyzed. The results show that the traffic restriction reduces road and construction dust fall significantly. The dust fall average value of ring roads was 0.27 g x (m2 x d)(-1) in the "traffic restriction" period, and the values were 0.81 and 0.59 g x (m2 x d)(-1) 1 month and 7 days before. The dust fall average value of major arterial and minor arterial was 0.21 g x (m2 x d)(-1) in the "traffic restriction" period, and the values were 0.54 and 0.58 g x (m2 x d)(-1) 1 month and 7 days before. The roads emission reduced 60%-70% compared with before traffic restriction. The dust fall average values of civil architecture and utility architecture were 0.61 and 1.06 g x (m2 x d)(-1) in the "traffic restriction" period, and the values were 1.15 and 1.55 g x (m2 x d)(-1) 20 days before. The construction dust reduced 30%-47% compared with 20 days before traffic restriction. Road and construction dust emission are the main source of atmosphere particulate matter in Beijing, and its contribution to ambient PM10 concentration is 21%-36%. PM10 emitted from roads and constructions account for 42%-72% and 30%-51% of local emission while the local PM10 account for 50% and 70% of the total emission.

  11. Increasing dust fluxes on the northeastern Tibetan Plateau linked with the Little Ice Age and recent human activity since the 1950s

    NASA Astrophysics Data System (ADS)

    Wan, Dejun; Jin, Zhangdong; Zhang, Fei; Song, Lei; Yang, Jinsong

    2016-12-01

    Arid and semi-arid areas in inner Asia contribute lots of mineral dust in the northern hemisphere, but dust flux evolution in the past is poorly constrained. Based on particle sizes and elemental compositions of a sediment core from Lake Qinghai on the northeastern Tibetan Plateau, dust fluxes during ∼1518-2011 A.D. were reconstructed based on 18-100 μm fractions of the lake sediment. The dust fluxes during the past ∼500 years ranged between 100 and 300 g/m2/yr, averaging 202 g/m2/yr, experiencing four stages: Stage 1 (∼1518-1590s), the flux was averaged 165 g/m2/yr, much lower than that in the Stage 2 (1590s-1730s, 254 g/m2/yr); similarly, an average flux of 169 g/m2/yr in the Stage 3 (1730s-1950s) was followed by an increased flux of 259 g/m2/yr in the Stage 4 (1950s-2011). During the first three stages the fluxes were dominated by natural dust activities in arid inner Asia, having a positive relation with wind intensity but a poor correlation with effective moisture (or precipitation) and temperature. The high dust flux in Stage 2 was due to relatively strong wind during the maximum Little Ice Age, whereas the remarkably high flux in 1950s-2011 was resulted from recent increasing human activities in northwestern China. The dust record not only documents past dust fluxes on the northeastern Tibetan Plateau but also reflects evolutions and mechanisms of dust activity/emission in inner Asia during the past ∼500 years.

  12. Toxicity of lunar dust assessed in inhalation-exposed rats

    PubMed Central

    Lam, Chiu-wing; Scully, Robert R.; Zhang, Ye; Renne, Roger A.; Hunter, Robert L.; McCluskey, Richard A.; Chen, Bean T.; Castranova, Vincent; Driscoll, Kevin E.; Gardner, Donald E.; McClellan, Roger O.; Cooper, Bonnie L.; McKay, David S.; Marshall, Linda; James, John T.

    2015-01-01

    Humans will again set foot on the moon. The moon is covered by a layer of fine dust, which can pose a respiratory hazard. We investigated the pulmonary toxicity of lunar dust in rats exposed to 0, 2.1, 6.8, 20.8 and 60.6 mg/m3 of respirable-size lunar dust for 4 weeks (6 h/day, 5 days/week); the aerosols in the nose-only exposure chambers were generated from a jet-mill ground preparation of a lunar soil collected during the Apollo 14 mission. After 4 weeks of exposure to air or lunar dust, groups of five rats were euthanized 1 day, 1 week, 4 weeks or 13 weeks after the last exposure for assessment of pulmonary toxicity. Biomarkers of toxicity assessed in bronchoalveolar fluids showed concentration-dependent changes; biomarkers that showed treatment effects were total cell and neutrophil counts, total protein concentrations and cellular enzymes (lactate dehydrogenase, glutamyl transferase and aspartate transaminase). No statistically significant differences in these biomarkers were detected between rats exposed to air and those exposed to the two low concentrations of lunar dust. Dose-dependent histopathology, including inflammation, septal thickening, fibrosis and granulomas, in the lung was observed at the two higher exposure concentrations. No lesions were detected in rats exposed to ≤6.8 mg/m3. This 4-week exposure study in rats showed that 6.8 mg/m3 was the highest no-observable-adverse-effect level (NOAEL). These results will be useful for assessing the health risk to humans of exposure to lunar dust, establishing human exposure limits and guiding the design of dust mitigation systems in lunar landers or habitats. PMID:24102467

  13. Toxicity of lunar dust assessed in inhalation-exposed rats.

    PubMed

    Lam, Chiu-wing; Scully, Robert R; Zhang, Ye; Renne, Roger A; Hunter, Robert L; McCluskey, Richard A; Chen, Bean T; Castranova, Vincent; Driscoll, Kevin E; Gardner, Donald E; McClellan, Roger O; Cooper, Bonnie L; McKay, David S; Marshall, Linda; James, John T

    2013-10-01

    Humans will again set foot on the moon. The moon is covered by a layer of fine dust, which can pose a respiratory hazard. We investigated the pulmonary toxicity of lunar dust in rats exposed to 0, 2.1, 6.8, 20.8 and 60.6 mg/m(3) of respirable-size lunar dust for 4 weeks (6 h/day, 5 days/week); the aerosols in the nose-only exposure chambers were generated from a jet-mill ground preparation of a lunar soil collected during the Apollo 14 mission. After 4 weeks of exposure to air or lunar dust, groups of five rats were euthanized 1 day, 1 week, 4 weeks or 13 weeks after the last exposure for assessment of pulmonary toxicity. Biomarkers of toxicity assessed in bronchoalveolar fluids showed concentration-dependent changes; biomarkers that showed treatment effects were total cell and neutrophil counts, total protein concentrations and cellular enzymes (lactate dehydrogenase, glutamyl transferase and aspartate transaminase). No statistically significant differences in these biomarkers were detected between rats exposed to air and those exposed to the two low concentrations of lunar dust. Dose-dependent histopathology, including inflammation, septal thickening, fibrosis and granulomas, in the lung was observed at the two higher exposure concentrations. No lesions were detected in rats exposed to ≤6.8 mg/m(3). This 4-week exposure study in rats showed that 6.8 mg/m(3) was the highest no-observable-adverse-effect level (NOAEL). These results will be useful for assessing the health risk to humans of exposure to lunar dust, establishing human exposure limits and guiding the design of dust mitigation systems in lunar landers or habitats.

  14. Health hazard evaluation report HETA 81-472-1380, Pennsylvania Power and Light, Martins Creek Steam Electric Station, Martins Creek, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, F.A.

    1983-10-01

    In August 1980, the National Institute for Occupational Safety and Health (NIOSH) received a request from the International Brotherhood of Electrical Workers Local 1600 for a Health Hazard Evaluation at the Pennsylvania Power and Light Company's Martins Creek Steam Electric Station in Martins Creek, Pennsylvania. The union was concerned about potential health and explosion hazards to employees from coal dust in Units 1 and 2 and the coal field. Based on environmental studies conducted at the time of the survey, NIOSH has determined that a potential health hazard may have existed due to exposure to respirable coal dust and quartz.more » Recommendations were made to ensure that potential health and explosion hazards are avoided in the future.« less

  15. Toxicity of mycotoxins for the rat pulmonary macrophage in vitro

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorenson, W.G.; Gerberick, G.F.; Lewis, D.M.

    1986-04-01

    The presence of mycotoxins in grains is well documented. Workers in grain handling occupations are commonly exposed to grain dust aerosols. Work in our laboratory has shown that T-2 toxin is highly toxic to rat alveolar macrophages in vitro, causing loss of viability, release of radiolabeled chromium, inhibition of macromolecular synthesis, inhibition of phagocytosis, and inhibition of macrophage activation. Similarly, patulin caused a significant release of radiolabeled chromium, decrease in ATP levels, significant inhibition of protein and RNA synthesis, and inhibition of phagocytosis. The data show that both T-2 toxin and patulin are highly toxic to rat alveolar macrophages inmore » vitro. The data further suggest that the presence of these mycotoxins in airborne respirable dust might present a hazard to exposed workers.« less

  16. Frost Induces Respiration and Accelerates Carbon Depletion in Trees.

    PubMed

    Sperling, Or; Earles, J Mason; Secchi, Francesca; Godfrey, Jessie; Zwieniecki, Maciej A

    2015-01-01

    Cellular respiration depletes stored carbohydrates during extended periods of limited photosynthesis, e.g. winter dormancy or drought. As respiration rate is largely a function of temperature, the thermal conditions during such periods may affect non-structural carbohydrate (NSC) availability and, ultimately, recovery. Here, we surveyed stem responses to temperature changes in 15 woody species. For two species with divergent respirational response to frost, P. integerrima and P. trichocarpa, we also examined corresponding changes in NSC levels. Finally, we simulated respiration-induced NSC depletion using historical temperature data for the western US. We report a novel finding that tree stems significantly increase respiration in response to near freezing temperatures. We observed this excess respiration in 13 of 15 species, deviating 10% to 170% over values predicted by the Arrhenius equation. Excess respiration persisted at temperatures above 0 °C during warming and reoccurred over multiple frost-warming cycles. A large adjustment of NSCs accompanied excess respiration in P. integerrima, whereas P. trichocarpa neither excessively respired nor adjusted NSCs. Over the course of the years included in our model, frost-induced respiration accelerated stem NSC consumption by 8.4 mg (glucose eq.) cm(-3) yr(-1) on average in the western US, a level of depletion that may continue to significantly affect spring NSC availability. This novel finding revises the current paradigm of low temperature respiration kinetics.

  17. Frost Induces Respiration and Accelerates Carbon Depletion in Trees

    PubMed Central

    Sperling, Or; Earles, J. Mason; Secchi, Francesca; Godfrey, Jessie; Zwieniecki, Maciej A.

    2015-01-01

    Cellular respiration depletes stored carbohydrates during extended periods of limited photosynthesis, e.g. winter dormancy or drought. As respiration rate is largely a function of temperature, the thermal conditions during such periods may affect non-structural carbohydrate (NSC) availability and, ultimately, recovery. Here, we surveyed stem responses to temperature changes in 15 woody species. For two species with divergent respirational response to frost, P. integerrima and P. trichocarpa, we also examined corresponding changes in NSC levels. Finally, we simulated respiration-induced NSC depletion using historical temperature data for the western US. We report a novel finding that tree stems significantly increase respiration in response to near freezing temperatures. We observed this excess respiration in 13 of 15 species, deviating 10% to 170% over values predicted by the Arrhenius equation. Excess respiration persisted at temperatures above 0°C during warming and reoccurred over multiple frost-warming cycles. A large adjustment of NSCs accompanied excess respiration in P. integerrima, whereas P. trichocarpa neither excessively respired nor adjusted NSCs. Over the course of the years included in our model, frost-induced respiration accelerated stem NSC consumption by 8.4 mg (glucose eq.) cm-3 yr-1 on average in the western US, a level of depletion that may continue to significantly affect spring NSC availability. This novel finding revises the current paradigm of low temperature respiration kinetics. PMID:26629819

  18. Assessment of dust exposure in a steel plant in the eastern coast of peninsular Malaysia.

    PubMed

    Nurul, Ainun Hamzah; Shamsul, Bahri Mohd Tamrin; Noor Hassim, Ismail

    2016-11-22

    Steel manufacturing produces dust, fumes, and pollutant gases that may give adverse health effects to the respiratory function of workers. Improper occupational hygiene practice in the workplace will affect both workers wellbeing and productivity. To assess the level of particulate matter [(PM2.5, PM10, and Total Particulate Matter (TPM)], and trace metal dust concentrations in different sections of a steel plant and compare with the occupational exposure values. The work environmental parameters of the particulate matters were evaluated using Indoor Air Quality, while metal dust concentrations were measured using portable personal air sampler. A total of 184 personal samples were randomly collected from workers in three major sections; steel making plant, direct reduced plant, and support group. Trace metal dust concentrations were subjected to wet mineral acid mixture digestion and analysed by atomic absorption spectrophotometer (AAS). The overall average PM2.5 concentration observed was varied according to the section: steel making plant was 0.18 mg/m3, direct reduced iron plant was 0.05 mg/m3, and support plant was 0.05 mg/m3. Average PM 10 concentration in steel making shop (SMS) plant, direct reduced (DR) plant, and support plant were 0.70 mg/m3, 0.84 mg/m3, and 0.58 mg/m3, respectively. The average TWA8 of trace metal dusts (cobalt and chromium) in all the sections exceeded 1 to 3 times the ACGIH prescribed values, OSHA PELs, NIOSH RELs as well as USECHH OSHA, whereas TWA8 concentration of nickel for each section did not exceed the occupational exposure values. The average PM2.5, PM10 and TPM did not exceed the prescribed values, while average trace metal dust concentration TWA8 for cobalt and chromium in all plants exceeded occupational exposure prescribed values. However, the nickel found did not exceed the prescribed values in all the plants except for NIOSH RELs.

  19. Historical climate controls soil respiration responses to current soil moisture.

    PubMed

    Hawkes, Christine V; Waring, Bonnie G; Rocca, Jennifer D; Kivlin, Stephanie N

    2017-06-13

    Ecosystem carbon losses from soil microbial respiration are a key component of global carbon cycling, resulting in the transfer of 40-70 Pg carbon from soil to the atmosphere each year. Because these microbial processes can feed back to climate change, understanding respiration responses to environmental factors is necessary for improved projections. We focus on respiration responses to soil moisture, which remain unresolved in ecosystem models. A common assumption of large-scale models is that soil microorganisms respond to moisture in the same way, regardless of location or climate. Here, we show that soil respiration is constrained by historical climate. We find that historical rainfall controls both the moisture dependence and sensitivity of respiration. Moisture sensitivity, defined as the slope of respiration vs. moisture, increased fourfold across a 480-mm rainfall gradient, resulting in twofold greater carbon loss on average in historically wetter soils compared with historically drier soils. The respiration-moisture relationship was resistant to environmental change in field common gardens and field rainfall manipulations, supporting a persistent effect of historical climate on microbial respiration. Based on these results, predicting future carbon cycling with climate change will require an understanding of the spatial variation and temporal lags in microbial responses created by historical rainfall.

  20. Saharan Dust Particle Size And Concentration Distribution In Central Ghana

    NASA Astrophysics Data System (ADS)

    Sunnu, A. K.

    2010-12-01

    A.K. Sunnu*, G. M. Afeti* and F. Resch+ *Department of Mechanical Engineering, Kwame Nkrumah University of Science and Technology (KNUST) Kumasi, Ghana. E-mail: albertsunnu@yahoo.com +Laboratoire Lepi, ISITV-Université du Sud Toulon-Var, 83162 La Valette cedex, France E-mail: resch@univ-tln.fr Keywords: Atmospheric aerosol; Saharan dust; Particle size distributions; Particle concentrations. Abstract The Saharan dust that is transported and deposited over many countries in the West African atmospheric environment (5°N), every year, during the months of November to March, known locally as the Harmattan season, have been studied over a 13-year period, between 1996 and 2009, using a location at Kumasi in central Ghana (6° 40'N, 1° 34'W) as the reference geographical point. The suspended Saharan dust particles were sampled by an optical particle counter, and the particle size distributions and concentrations were analysed. The counter gives the total dust loads as number of particles per unit volume of air. The optical particle counter used did not discriminate the smoke fractions (due to spontaneous bush fires during the dry season) from the Saharan dust. Within the particle size range measured (0.5 μm-25 μm.), the average inter-annual mean particle diameter, number and mass concentrations during the northern winter months of January and February were determined. The average daily number concentrations ranged from 15 particles/cm3 to 63 particles/cm3 with an average of 31 particles/cm3. The average daily mass concentrations ranged from 122 μg/m3 to 1344 μg/m3 with an average of 532 μg/m3. The measured particle concentrations outside the winter period were consistently less than 10 cm-3. The overall dust mean particle diameter, analyzed from the peak representative Harmattan periods over the 13-year period, ranged from 0.89 μm to 2.43 μm with an average of 1.5 μm ± 0.5. The particle size distributions exhibited the typical distribution pattern for atmospheric aerosols with a coarse mode diameter situated at about 3.5 μm. The experimental results reported in this study will be important in validating satellite based observations and simulation models of the African dust plume towards the Gulf of Guinea during winter.

  1. [Soil respiration and carbon balance in wheat field under conservation tillage].

    PubMed

    Zhang, Sai; Wang, Long-Chang; Huang, Zhao-Cun; Jia, Hui-Juan; Ran, Chun-Yan

    2014-06-01

    In order to study the characteristics of carbon sources and sinks in the winter wheat farmland ecosystem in southwest hilly region of China, the LI6400-09 respiratory chamber was adopted in the experiment conducted in the experimental field in Southwest University in Chongqing. The soil respiration and plant growth dynamics were analyzed during the growth period of wheat in the triple intercropping system of wheat-maize-soybean. Four treatments including T (traditional tillage), R (ridge tillage), TS (traditional tillage + straw mulching), and RS (ridge tillage + straw mulching) were designed. Root biomass regression (RR) and root exclusion (RE) were used to compare the contribution of root respiration to total soil respiration. The results showed that the average soil respiration rate was 1.71 micromol x (m2 x s)(-1) with a variation of 0.62-2.91 micromol x (m2 x s)(-1). Significant differences in soil respiration rate were detected among different treatments. The average soil respiration rate of T, R, TS and RS were 1.29, 1.59, 1.99 and 1.96 micromol x (m2 x s)(-1), respectively. R treatment did not increase the soil respiration rate significantly until the jointing stage. Straw mulching treatment significantly increased soil respiration, with a steadily high rate during the whole growth period. During the 169 days of growth, the total soil respiration was 2 266.82, 2799.52, 3 483.73 and 3 443.89 kg x hm(-2) while the cumulative aboveground biomasses were 51 800.84, 59 563.20, 66 015.37 and 7 1331.63 kg x hm(-2). Compared with the control, the yield of R, TS and RS increased by 14.99%, 27.44% and 37.70%, respectively. The contribution of root respiration to total soil respiration was 47.05% by RBR, while it was 53.97% by RE. In the early growth period, the carbon source was weak. The capacity of carbon sink started to increase at the jointing stage and reached the maximum during the filling stage. The carbon budget of wheat field was 5 924.512, 6743.807, 8350.741, 8 876.115 kg x hm(-2), respectively. The results indicated that ridge tillage and straw mulching conservation tillage significantly improved the carbon sink in the wheat farmland ecosystem.

  2. Computational fluid dynamic modeling of a medium-sized surface mine blasthole drill shroud

    PubMed Central

    Zheng, Y.; Reed, W.R.; Zhou, L.; Rider, J.P.

    2016-01-01

    The Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health (NIOSH) recently developed a series of models using computational fluid dynamics (CFD) to study airflows and respirable dust distribution associated with a medium-sized surface blasthole drill shroud with a dry dust collector system. Previously run experiments conducted in NIOSH’s full-scale drill shroud laboratory were used to validate the models. The setup values in the CFD models were calculated from experimental data obtained from the drill shroud laboratory and measurements of test material particle size. Subsequent simulation results were compared with the experimental data for several test scenarios, including 0.14 m3/s (300 cfm) and 0.24 m3/s (500 cfm) bailing airflow with 2:1, 3:1 and 4:1 dust collector-to-bailing airflow ratios. For the 2:1 and 3:1 ratios, the calculated dust concentrations from the CFD models were within the 95 percent confidence intervals of the experimental data. This paper describes the methodology used to develop the CFD models, to calculate the model input and to validate the models based on the experimental data. Problem regions were identified and revealed by the study. The simulation results could be used for future development of dust control methods for a surface mine blasthole drill shroud. PMID:27932851

  3. Atmospherically transported elements and deposition in the Southeastern United States: Local or transoceanic?

    USGS Publications Warehouse

    Holmes, C.W.; Miller, R.

    2004-01-01

    Saharan dust is persistently transported and deposited in ecosystems of the western Atlantic Ocean. This dust is an aggregate of clay and quartz particles cemented with Fe oxides. Samples collected and analyzed from Mali (central Africa), the Azores, the Caribbean and the Eastern United States document the levels of minor and trace metals in the dust. Metal loadings, particularly the toxic elements - Hg and As, are significantly higher than average crustal rocks. Over the past decade, the focus has been to understand the cycling of Hg in south Florida, but As has received very little attention. Arsenic in the sediment deposited in the past decade in south Florida averages 14 mg/kg and appears to be correlated with Al, a proxy for dust. The largest available aerosol data set containing As is the IMPROVE (Interagency Monitoring of Protected Visual Environments) data set. The average concentrations in aerosols collected during this program range from 17 mg/kg in the Virgin Islands to 79 mg/kg at Chassahowitzka, Florida. At Chassahowitzka, most of the As appears to be associated with organic C. If it is assumed that the concentrations in Mali dust and in the aerosols in the Virgin Islands are indicative of soil dust, then the higher values at Chassahowitzka may be derived from local or regional sources. A simple calculation indicates that African dust supplies about 25% of the As deposited from aerosols in the southeastern United States. Comparison of the average yearly As concentrations measured in the Virgin Islands and Everglades shows a negative relationship with the North Atlantic Oscillation (NAO). This relationship demonstrates the influence of climate on the transport and deposition of aerosols to the southeastern United States.

  4. Meridional Distribution of Aerosol Optical Thickness over the Tropical Atlantic Ocean

    NASA Technical Reports Server (NTRS)

    Kishcha, P.; Silva, Arlindo M.; Starobinets, B.; Long, C. N.; Kalashnikova, O.; Alpert, P.

    2015-01-01

    Previous studies showed that, over the global ocean, there is hemispheric asymmetry in aerosols and no noticeable asymmetry in cloud fraction (CF). In the current study, we focus on the tropical Atlantic (30 Deg N 30 Deg S) which is characterized by significant amounts of Saharan dust dominating other aerosol species over the North Atlantic. We found that, by contrast to the global ocean, over a limited area such as the tropical Atlantic, strong meridional asymmetry in dust aerosols was accompanied by meridional CF asymmetry. During the 10-year study period (July 2002 June 2012), NASA Aerosol Reanalysis (aka MERRAero) showed that, when the meridional asymmetry in dust aerosol optical thickness (AOT) was the most pronounced (particularly in July), dust AOT averaged separately over the tropical North Atlantic was one order of magnitude higher than dust AOT averaged over the tropical South Atlantic. In the presence of such strong meridional asymmetry in dust AOT in July, CF averaged separately over the tropical North Atlantic exceeded CF averaged over the tropical South Atlantic by 20%. Our study showed significant cloud cover, up to 0.8 - 0.9, in July along the Saharan Air Layer which contributed to above-mentioned meridional CF asymmetry. Both Multi-Angle Imaging SpectroRadiometer (MISR) measurements and MERRAero data were in agreement on seasonal variations in meridional aerosol asymmetry. Meridional asymmetry in total AOT over the Atlantic was the most pronounced between March and July, when dust presence over the North Atlantic was maximal. In September and October, there was no noticeable meridional asymmetry in total AOT and meridional CF distribution over the tropical Atlantic was almost symmetrical.

  5. Environmental Sensor Technologies and Procedures for Detecting and Identifying Indoor Air Pollution

    DTIC Science & Technology

    1992-03-01

    problem of radon or biological contaminants. Radon daughters --the radioactive decay products of radon gas-are most dangerous when they attach to a...entry points. Radon itself decays into radon daughters which are dangerous when they bond with dust particles that allow them to embed in the lining...because it contains respirable particles to which radon daughters can attach and embed in the lungs. The most direct way to check the ETS level is to

  6. Environmental Sensor Technologies and Procedures for Detecting and Identifying Indoor Air Pollution

    DTIC Science & Technology

    1992-03-01

    level of RSP in the air. RSP aggravates dust-related allergies. It also aggravates the problem of radon or biological contaminants. Radon daughters -the...the earth and is pulled into buildings through cracks in the foundation and other entry points. Radon itself decays into radon daughters which are...heart disease. ETS aggravates the danger of exposure to radon by a factor of 5 because it contains respirable particles to which radon daughters can

  7. Mine safety: Occupational health -- general studies. (Latest citations from the NTIS bibliographic database). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-07-01

    The bibliography contains citations concerning occupational hazards in the metals and fossil fuel mining environment. Topics include the detection, control and effects of respirable dust, safety aspects of various mining methods, gas detection, and field surveys of specific operations. Some attention is given to legislative aspects of mine safety and benefits to the disabled.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  8. 29 CFR 1915.1000 - Air contaminants.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... E Octachloronaphthalene 2234-13-1 — 0.1 X Octane 111-65-9 400 1900 — Oil mist, mineral 8012-95-1 — 5... — Turpentine 8006-64-2 100 560 — Uranium (as U) 7440-61-1 Soluble compounds — 0.2 — Insoluble compounds — 0.2 — Vanadium 1314-62-1 Respirable dust (as V2 O5) — (C)0.5 — Fume (as V2 O5) — (C)0.1 — Vegetable oil mist...

  9. 29 CFR 1915.1000 - Air contaminants.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... E Octachloronaphthalene 2234-13-1 — 0.1 X Octane 111-65-9 400 1900 — Oil mist, mineral 8012-95-1 — 5... — Turpentine 8006-64-2 100 560 — Uranium (as U) 7440-61-1 Soluble compounds — 0.2 — Insoluble compounds — 0.2 — Vanadium 1314-62-1 Respirable dust (as V2 O5) — (C)0.5 — Fume (as V2 O5) — (C)0.1 — Vegetable oil mist...

  10. 29 CFR 1915.1000 - Air contaminants.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... E Octachloronaphthalene 2234-13-1 — 0.1 X Octane 111-65-9 400 1900 — Oil mist, mineral 8012-95-1 — 5... — Turpentine 8006-64-2 100 560 — Uranium (as U) 7440-61-1 Soluble compounds — 0.2 — Insoluble compounds — 0.2 — Vanadium 1314-62-1 Respirable dust (as V2 O5) — (C)0.5 — Fume (as V2 O5) — (C)0.1 — Vegetable oil mist...

  11. Investigation of effects of prolonged inhalation of nickel-enriched fly ash in Syrian Golden hamsters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wehner, A.P.

    1981-01-01

    Groups of 102 Male Syrian Golden hamsters were chronically exposed to approx. 70 micrograms/l respirable Nickel Enriched Fly Ash aerosol (high NEFA group), approx. 17 micrograms/l (low NEFA group), or approx. 70 micrograms/l FA 6 hrs/day, 5 days/week for 4, 8, 12, 16, and 20 months. Identical control groups received sham exposures. The NEFA particles of respirable size contained approximately 6% nickel, compared to about 0.3% for FA. Exposure to NEFA had no significant effect on the apparent well being, body weight and life span of the animals although heavy deposits of NEFA in the lungs were found. The lungmore » weights and mean lung volumes of the high NEFA and FA exposed animals were significantly higher and larger, respectively, than for the low NEFA and control groups. There was a 100% incidence of dust deposition (anthracosis) and significantly higher incidence plus severity of interstitial reaction and bronchiolization in the dust-exposed groups than the controls. The severity of lung reactions was significantly lower in the low NEFA group than the high NEFA and FA groups. The results of this study conclude that the addition of nickel to fly ash under these conditions did not significantly (P< 0.05) enhance the pathogenicity (including carcinogenicity) of fly ash in this animal model.« less

  12. Control technology assessment for coal gasification and liquefaction processes, coal gasification facility, Caterpillar Tractor Company, York, Pennsylvania. Report for the site visit of May 1981. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Telesca, D.R.

    A control technology survey was conducted at the coal gasification facility of the Caterpillar Tractor Company (SIC-5161), in York, Pennsylvania on August 18, 1980 and May 7, 1981, in conjunction with an industrial hygiene characterization study. Potential hazards included coal dust, noise, fire, carbon-monoxide (630080) (CO), polynuclear aromatics, hydrogen sulfide (7783064), phenols, and flammable and explosive gases. Preemployment physicals were given to employees including complete medical histories, physical examinations, and skin examination. Examinations were given annually for the first 5 years and semiannually thereafter. The most hazardous activities were poking, cleaning, inspection of process equipment, and equipment maintenance. Coal dustmore » emissions were effectively reduced by enclosure and venting. Venturi steam injectors in the gasifier pokeholes prevented gas emissions during poking. Ash dust was controlled by removal and handling while it was wet. An audible and visual alarm was used for CO monitoring. The ventilation system in the building effectively prevented accumulation of gases. The author recommends separate lockers for contaminated and clean clothing; a clean area for eating; escape pack respirators located in the rectifier room, control room, and coal bunker; and supplied air respirators in dangerous areas. Disposal of off gas from the feeding system should be addressed.« less

  13. Pulmonary epithelial response in the rat lung to instilled Montserrat respirable dusts and their major mineral components

    PubMed Central

    Housley, D; Berube, K; Jones, T; Anderson, S; Pooley, F; Richards, R

    2002-01-01

    Background: The Soufriere Hills, a stratovolcano on Montserrat, started erupting in July 1995, producing volcanic ash, both from dome collapse pyroclastic flows and phreatic explosions. The eruptions/ash resuspension result in high concentrations of suspended particulate matter in the atmosphere, which includes cristobalite, a mineral implicated in respiratory disorders. Aims: To conduct toxicological studies on characterised samples of ash, together with major components of the dust mixture (anorthite, cristobalite), and a bioreactive mineral control (DQ12 quartz). Methods: Rats were challenged with a single mass (1 mg) dose of particles via intratracheal instillation and groups sacrificed at one, three, and nine weeks. Acute bioreactivity of the particles was assessed by increases in lung permeability and inflammation, changes in epithelial cell markers, and increase in the size of bronchothoracic lymph nodes. Results: Data indicated that respirable ash derived from pyroclastic flows (20.1% cristobalite) or phreatic explosion (8.6% cristobalite) had minimal bioreactivity in the lung. Anorthite showed low bioreactivity, in contrast to pure cristobalite, which showed progressive increases in lung damage. Conclusion: Results suggests that either the percentage mass of cristobalite particles present in Montserrat ash was not sufficient as a catalyst in the lung environment, or its surface reactivity was masked by the non-reactive volcanic glass components during the process of ash formation. PMID:12107295

  14. Can Lightning Produce Significant Levels of Mass-Independent Oxygen Isotopic Fractionation in Nebular Dust?

    NASA Technical Reports Server (NTRS)

    Nuth, Joseph A.; Paquette, John A.; Farquhar, Adam

    2012-01-01

    Based on recent evidence that oxide grains condensed from a plasma will contain oxygen that is mass independently fractionated compared to the initial composition of the vapor, we present a first attempt to evaluate the potential magnitude of this effect on dust in the primitive solar nebula. This assessment relies on previous studies of nebular lightning to provide reasonable ranges of physical parameters to form a very simple model to evaluate the plausibility that lightning could affect a significant fraction of nebular dust and that such effects could cause a significant change in the oxygen isotopic composition of solids in the solar nebula over time. If only a small fraction of the accretion energy is dissipated as lightning over the volume of the inner solar nebula, then a large fraction of nebular dust will be exposed to lightning. If the temperature of such bolts is a few percent of the temperatures measured in terrestrial discharges, then dust will vaporize and recondense in an ionized environment. Finally, if only a small average decrease is assumed in the O-16 content of freshly condensed dust, then over the last 5 million years of nebular accretion the average delta O-17 of the dust could increase by more than 30 per mil. We conclude that it is possible that the measured " slope 1" oxygen isotope line measured in meteorites and their components represents a time-evolution sequence of nebular dust over the last several million years of nebular evolution O-16-rich materials formed first, then escaped further processing as the average isotopic composition of the dust graduaUy became increasingly depleted in O-16 .

  15. Multi-decadal and seasonal variability of dust observations in West Greenland.

    NASA Astrophysics Data System (ADS)

    Bullard, Joanna E.; Mockford, Tom

    2017-04-01

    Since the early 1900s expedition records from west Greenland have reported local dust storms. The Kangerlussuaq region, near the inland ice, is dry (mean annual precipitation <160 mm) with, on average, 150 snow-free days per year. The main local dust sources are active, proglacial outwash plains although reworking of loess deposits may also be important. This paper presents an analysis of 70-years of dust storm observations (1945-2015) based on WMO weather codes 6 (dust haze), 7 (raised dust or sand) and 9 (distant or past dust storm) and associated wind data. The 70-year average number of dust observations days is 5 per year but variable ranging from 0 observations to 23 observations in 1985. Over the past 7 decades the number of dust days has increased from <30 in 1945-54 to >75 in 1995-2004 and 2005-2015. The seasonality of dust observations has remained consistent throughout most of the period. Dust days occur all year round but are most frequent in May-June and September-October and are associated with minimum snow cover and glacial meltwater-driven sediment supply to the outwash plains during spring and fall flood events. Wind regime is bimodal dominated by katabatic winds from the northeast, which are strongest and most frequent during winter months (Nov-Jan), with less frequent, southwesterly winds generated by Atlantic storms mostly confined to spring (May, June). The southwesterly winds are those most likely to transport dust onto the Greenland ice sheet.

  16. Engineering control technologies to reduce occupational silica exposures in masonry cutting and tuckpointing.

    PubMed

    Meeker, John D; Cooper, Michael R; Lefkowitz, Daniel; Susi, Pam

    2009-01-01

    A number of tasks in construction generate worker overexposures to respirable crystalline silica dust, which is a significant contributor to occupational mortality and morbidity. This study evaluated the performance of commercially available engineering controls used in dusty construction tasks commonly performed by bricklayers. Local exhaust ventilation (LEV) controls for a portable abrasive cutter and for tuckpointing grinders were examined at a bricklayers' training center, as were two stationary wet saws. Personal breathing zone air samples were collected with and without the use of LEV or water suppression during simulated concrete block cutting, brick cutting, and tuckpointing. Compared with the use of no exposure control during block and brick cutting, the portable LEV unit significantly reduced mean respirable quartz exposures by 96% for block cutting and 91% for brick cutting (p < 0.01). The use of stationary wet saws was also associated with 91% reductions in exposure (p < 0.01). For tuckpointing, the reductions in mean respirable quartz concentrations were between 91% and 93% with the LEV controls (p < 0.05). Reductions of up to 96% in mean respirable quartz concentration were observed between control and no-control scenarios. These reductions with commercially available off-the-shelf tools demonstrate the effectiveness of engineering control interventions to reduce crystalline silica exposures in construction. Strategies to further improve control performance and approaches for increasing control interventions in construction are needed.

  17. Spatial distribution, health risk assessment, and isotopic composition of lead contamination of street dusts in different functional areas of Beijing, China.

    PubMed

    Han, Lanfang; Gao, Bo; Wei, Xin; Xu, Dongyu; Gao, Li

    2016-02-01

    Street dusts from heavy density traffic area (HDTA), tourism area (TA), residential area (RA), and educational area (EA) in Beijing were collected to explore the distribution, health risk assessment, and source of lead (Pb). The average concentration of Pb in TA was the highest among the four areas. Compared with other cities, Pb concentrations in Beijing were generally at moderate or low levels. The average value (14.05) of ecological risk index (RI) indicated that Pb was at "low pollution risk" status. According to the calculation on hazard index (HI), the ingestion of dust particles of children and adults was the major route of exposure to street dusts in four studied areas, followed by dermal contact. The lower values of HI than 1 further suggested that non-carcinogenic risks of Pb in the street dusts were in the low range. Comparing (206)Pb/(207)Pb and (208)Pb/(207)Pb ratios of street dusts with other environmental samples, it was found that atmospheric deposition of coal combustion dust might be the main pathway for anthropogenic Pb input to the street dusts in four functional areas.

  18. The Lunar Environment: Determining the Health Effects of Exposure to Moon Dusts

    NASA Technical Reports Server (NTRS)

    Khan-Mayberry, Noreen

    2007-01-01

    The Earth s moon presents a hostile environment in which to live and work. There is no atmosphere to protect its surface from the ravages of solar wind and micrometeorite impacts. As a result, the moon s surface is covered with a thin layer of fine, charged, reactive dust capable of entering habitats and vehicle compartments, where it can result in crewmember health problems. During the Apollo missions, lunar dusts were introduced into the crew vehicle, resulting in direct exposure and occasional reports of respiratory, dermal and ocular irritation. In order to study the toxicological effects of lunar dust, NASA formed the Lunar Airborne Dust Toxicity Advisory Group (LADTAG). This interdisciplinary group is comprised of leading experts in space toxicology, lunar geology, space medicine and biomedical research. LADTAG has demonstrated that lunar soil contains several types of reactive dusts, including an extremely fine respirable component. These dusts have highly reactive surfaces in the lunar environment; the grains contain surface coatings which are generated by vapor phases formed by hypervelocity impact of micrometeorites. This unique class of dusts has surface properties that are unlike any Earth based analog. These distinctive properties are why lunar dusts are of great toxicological interest. Understanding how these reactive components behave "biochemically" in a moisture-rich pulmonary environment will aid in determining how toxic these particles are to humans. The data obtained from toxicological examination of lunar dusts will determine the human risk criteria for lunar dust exposure and produce a lunar health standard. LADTAG s analysis of lunar dusts and lunar dust simulants will include detailed lunar particle characterizations, determining the properties of particle activation, reactivation of lunar dust, the process of dust passivation and discerning the pathology of lunar dust exposure via inhalation, intratracheal instillation, cell culture exposure, dermal exposure and ocular exposure. The resulting health standard will be time-based and will vary by the duration and type of exposure. It may also be necessary to set multiple standards for different types of lunar dust, as well as for dust in its activated form vs. aged & passivated dust. This standard, set to protect the health of our robust astronaut crews, will not only impact NASA medical operations, but engineering designs as well. The data from our multidisciplinary research are vital in developing remediation devices and environmental monitors. Ultimately, the engineering and safety groups will design and develop countermeasures for space vehicles, suits, rovers and habitats that will be sustained within the limits of the health standard.

  19. Analysis of dust storms observed in Mongolia during 1937-1999

    NASA Astrophysics Data System (ADS)

    Natsagdorj, L.; Jugder, D.; Chung, Y. S.

    Climatology of dust storms in Mongolia is compiled based on observational data of 49 meteorological stations from 1960 to 1999 and compared them with data between 1937 and 1989. Three different maps of the distribution of dust storms, drifting dust and the number of dusty days are presented. The results of the analysis show that the number of days with dust storms is <5 days over the Altai, the Khangai and the Khentei mountainous regions and more than 20-37 days in the Gobi Desert and semi-desert area. The greatest occurrence of drifting dust arises around the Mongol Els area of west Mongolia. The number of dusty days, which is derived from the sum of the number of days with dust storms and drifting dust, is <10 days in the mountainous area and 61-127 days in the Gobi Desert and the Great Lakes hollow of west Mongolia. It is found that 61% of dust storms occur in the spring in Mongolia and a dust storm lasts on average from 3.1 to 6.0 h. About 65.5-91.0% of dust storms occur in daytime and 9.0-34.5% at night. Dust storms occur more frequently in the city region and are accompanied by surface wind speeds usually from 6 to 20 ms -1. Dust storms usually occur when soil and air are dry, and 70% of dust storms occur in dry soil conditions. When dust storms occur, relative humidity averages 20-40% in Mongolia. An important outcome of this study is the trend of dusty days between 1960 and 1999. It shows that the number of dusty days has tripled from the 1960s to 1990s and has decreased since 1990.

  20. Ecological Restoration Programs Induced Amelioration of the Dust Pollution in North China Plain

    NASA Astrophysics Data System (ADS)

    Long, X.; Tie, X.; Li, G.; Junji, C.

    2017-12-01

    With Moderate Resolution Imaging Spectroradiometer (MODIS) land cover product (MCD12Q1), we quantitatively evaluate the ecological restoration programs (ERP) induced land cover change in China by calculating gridded the land use fraction (LUF). We clearly capture two obvious vegetation (grass and forest) protective barriers arise between the dust source region DSR and North China Plain NCP from 2011 to 2013. The WRF-DUST model is applied to investigate the impact of ERPs on dust pollution from 2 to 8 March 2016, corresponding to a national dust storm event over China. Despite some model biases, the WRF-DUST model reasonably reproduced the temporal variations of dust storm event, involving IOA of 0.96 and NMB of 2% for DSR, with IOA of 0.83 and NMB of -15% for downwind area of NCP. Generally, the WRF-DUST model well capture the spatial variations and evolutions of dust storm events with episode-average [PMC] correlation coefficient (R) of 0.77, especially the dust storm outbreak and transport evolution, involving daily average [PMC] R of 0.9 and 0.73 on 4-5 March, respectively. It is found that the ERPs generally reduce the dust pollution in NCP, especially for BTH, involving upper dust pollution control benefits of -15.3% (-21.0 μg m-3) for BTH, and -6.2% (-9.3 μg m-3) for NCP. We are the first to conduct model sensitivity studies to quantitatively evaluate the impacts of the ERPs on the dust pollution in NCP. And our narrative is independently based on first-hand sources, whereas government statistics.

Top