Vizzeri, Gianmarco; Bowd, Christopher; Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M
2008-08-01
Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Observational clinical study. Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered on the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 microm), superiorly (106.2 microm), or inferiorly (104.1 microm) displaced scans and the centered scans (106.4 microm). However, a significant difference (analysis of variance with Dunnett's test: F=8.82, P<0.0001) was found between temporally displaced scans (115.8 microm) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. In normal eyes, average RNFL thickness measurements are robust and similar with significant superior, inferior, and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.
Cordeiro, Daniela Valença; Lima, Verônica Castro; Castro, Dinorah P; Castro, Leonardo C; Pacheco, Maria Angélica; Lee, Jae Min; Dimantas, Marcelo I; Prata, Tiago Santos
2011-01-01
To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect was observed.
Seo, Sam; Lee, Chong Eun; Jeong, Jae Hoon; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2017-03-11
To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm 2 , P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.
Huynh, Son C; Wang, Xiu Ying; Rochtchina, Elena; Mitchell, Paul
2006-09-01
To study the distribution of retinal nerve fiber layer (RNFL) thickness by ocular and demographic variables in a population-based study of young children. Population-based cross-sectional study. One thousand seven hundred sixty-five of 2238 (78.9%) eligible 6-year-old children participated in the Sydney Childhood Eye Study between 2003 and 2004. Mean age was 6.7 years (50.9% boys). Detailed examination included cycloplegic autorefraction and measurement of axial length. Retinal nerve fiber layer scans using an optical coherence tomographer were performed with a circular scan pattern of 3.4-mm diameter. Multivariate analyses were performed to examine the distribution of RNFL parameters with gender, ethnicity, axial length, and refraction. Peripapillary RNFL thickness and RNFL(estimated integral) (RNFL(EI)), which measures the total cross-sectional area of ganglion cell axons converging onto the optic nerve head. Peripapillary RNFL thickness and RNFL(EI) were normally distributed. The mean+/-standard deviation RNFL average thickness was 103.7+/-11.4 microm and RNFL(EI) was 1.05+/-0.12 mm2. Retinal nerve fiber layer thickness was least for the temporal quadrant (75.7+/-14.7 microm), followed by the nasal (81.7+/-19.6 microm), inferior (127.8+/-20.5 microm), and superior (129.5+/-20.6 microm) quadrants. Multivariate adjusted RNFL average thickness was marginally greater in boys than in girls (104.7 microm vs. 103.2 microm; P = 0.007) and in East Asian than in white children (107.7 microm vs. 102.7 microm; P<0.0001). The RNFL was thinner with greater axial length (P(trend)<0.0001) and less positive spherical equivalent refractions (P(trend) = 0.004). Retinal nerve fiber layer average thickness and RNFL(EI) followed a normal distribution. Retinal nerve fiber layer thickness varied marginally with gender, but differences were more marked between white and East Asian children. Retinal nerve fiber layer thinning was associated with increasing axial length and less positive refractions.
Characteristics of peripapillary retinal nerve fiber layer in preterm children.
Wang, Jingyun; Spencer, Rand; Leffler, Joel N; Birch, Eileen E
2012-05-01
To examine quantitatively characteristics of the peripapillary retinal nerve fiber layer (RNFL) in preterm children using Fourier-domain optical coherence tomography (FD-OCT). Prospective cross-sectional study. A 3-mm high-resolution FD-OCT peripapillary RNFL circular scan centered on the optic disc was obtained from right eyes of 25 preterm children (10.6 ± 3.7 years old, 8 preterm and 17 with regressed retinopathy of prematurity with normal-appearing posterior poles) and 54 full-term controls (9.8 ± 3.2 years old). Images were analyzed using Spectralis FD-OCT software to obtain average thickness measurements for 6 sectors (temporal superior, temporal, temporal inferior, nasal inferior, nasal, nasal superior), and the global average. The RNFL global average for preterm children was 8% thinner than for full-term controls. In the preterm group, peripapillary RNFL thickness on the temporal side of the disc was 6% thicker than in full-term controls, while all other peripapillary RNFL sectors were 9% to 13% thinner. In the preterm group, temporal sector peripapillary RNFL thickness was correlated with gestational age (r = -0.47, P < .001), with foveal center total thickness (r = 0.48, P = .008, 1-tailed), and with visual acuity (r = 0.42; P = .026, 1-tailed). The significantly thinner RNFL global average for preterm children suggests that prematurity is associated with subclinical optic nerve hypoplasia. Significant correlations between temporal sector RNFL thickness and both the foveal thickness and visual acuity suggest that the peripapillary RNFL is related to abnormalities in macular development as a result of preterm birth. Copyright © 2012 Elsevier Inc. All rights reserved.
Mittal, Deepti; Dubey, Suneeta; Gandhi, Monica; Pegu, Julie; Bhoot, Madhu; Gupta, Yadunandan Prasad
2018-01-01
Purpose: The aim of this study is to determine which parameter of Cirrus and RTVue optical coherence tomography (OCT) has the highest ability to discriminate between early, moderate, and advanced glaucoma. Simultaneously, to compare the performance of the two OCT devices in terms of their ability to differentiate the three stages of glaucoma. Further, to analyze the macular parameters of both devices and compare them with the conventional retinal nerve fiber layer (RNFL) parameters. Methods: One hundred and twenty eyes (30 healthy and 90 glaucomatous [30 mild, 30 moderate, and 30 advanced glaucoma]) of 65 participants (15 healthy, 50 glaucomatous [15 mild, 15 moderate, and 20 advanced glaucoma]) underwent Cirrus and RTVue OCT scanning on a single visit. Results: Average RNFL thickness and superior RNFL thickness of both the devices and inferior (ganglion cell complex [GCC] of RTVue device best differentiated normals from all stage glaucomatous eyes (P > 0.05). Cirrus average RNFL thickness and superior RNFL thickness performed better than other parameters (P < 0.05) in differentiating early glaucoma from moderate and advanced. In differentiating advanced from early and moderate glaucoma, RTVue average, superior, and inferior RNFL thickness and inferior GCC parameters had the highest discriminating ability (P < 0.05). Conclusion: Overall, average RNFL thickness had the highest ability to distinguish different stages of the disease. No significant difference was found between RTVue and Cirrus OCT device in different severity levels. No significant difference was observed between RNFL and macular parameters in different stages of glaucoma. PMID:29676314
Mittal, Deepti; Dubey, Suneeta; Gandhi, Monica; Pegu, Julie; Bhoot, Madhu; Gupta, Yadunandan Prasad
2018-05-01
The aim of this study is to determine which parameter of Cirrus and RTVue optical coherence tomography (OCT) has the highest ability to discriminate between early, moderate, and advanced glaucoma. Simultaneously, to compare the performance of the two OCT devices in terms of their ability to differentiate the three stages of glaucoma. Further, to analyze the macular parameters of both devices and compare them with the conventional retinal nerve fiber layer (RNFL) parameters. One hundred and twenty eyes (30 healthy and 90 glaucomatous [30 mild, 30 moderate, and 30 advanced glaucoma]) of 65 participants (15 healthy, 50 glaucomatous [15 mild, 15 moderate, and 20 advanced glaucoma]) underwent Cirrus and RTVue OCT scanning on a single visit. Average RNFL thickness and superior RNFL thickness of both the devices and inferior (ganglion cell complex [GCC] of RTVue device best differentiated normals from all stage glaucomatous eyes (P > 0.05). Cirrus average RNFL thickness and superior RNFL thickness performed better than other parameters (P < 0.05) in differentiating early glaucoma from moderate and advanced. In differentiating advanced from early and moderate glaucoma, RTVue average, superior, and inferior RNFL thickness and inferior GCC parameters had the highest discriminating ability (P < 0.05). Overall, average RNFL thickness had the highest ability to distinguish different stages of the disease. No significant difference was found between RTVue and Cirrus OCT device in different severity levels. No significant difference was observed between RNFL and macular parameters in different stages of glaucoma.
Wang, Xiao-en; Wang, Xiao-yu; Gu, Yang-shun; Huang, Zhu
2013-01-01
Fundus changes associated with high myopia (HM) may mask those associated with primary open-angle glaucoma (POAG). This study aim to determine the characteristics of RNFL thickness changes in patients with both POAG and HM and compare these to changes in patients with only HM. The diagnostic capabilities of both OCT and GDxVCC in this subset of patients are also evaluated. Twenty-two eyes with POAG and HM (spherical equivalent (SE) between -6.0 and -12.0 D) were evaluated, and 22 eyes with HM were used for comparison. Characteristic retinal nerve fiber layer (RNFL) thickness profiles in patients with POAG and HM were examined using optical coherence tomography (OCT) and scanning laser polarimetry with variable corneal compensation (GDxVCC), and the diagnostic capabilities of these imaging modalities were compared. RNFL parameters evaluated included superior average (Savg-GDx), inferior average (Iavg-GDx), temporal-superior-nasal- inferior-temporal (TSNIT) average, and nerve fiber indicator (NFI) on GDxVCC and superior average (Savg-OCT), inferior average (Iavg-OCT), nasal average (Navg-OCT), temporal average (Tavg-OCT), and average thickness (AvgThick-OCT) on OCT (fast RNFL scan). Visual field testing was performed and defects were evaluated using mean defect (MD) and pattern standard deviation (PSD). The RNFL parameters (P < 0.05) significantly different between groups included Savg-GDx, Iavg-GDx, TSNIT average, NFI, Savg-OCT, Iavg-OCT, Tavg-OCT, and AvgThick-OCT. Significant correlations existed between TSNIT average and AvgThick-OCT (r = 0.778), TSNIT average and MD (r = 0.749), AvgThick-OCT and MD (r = 0.647), TSNIT average and PSD (r = -0.756), and AvgThick-OCT and PSD (r = -0.784). The area under the receiver operating characteristic curve (AUROC) values of TSNIT average, Savg-GDx, Iavg-GDx, NFI, Savg-OCT, Iavg-OCT, Navg-OCT, Tavg-OCT, and AvgThick-OCT were 0.947, 0.962, 0.973, 0.994, 0.909, 0.917, 0.511, 0.906, and 0.913, respectively. The NFI AUROC was the highest value. RNFL thickness was significantly lower in all but the nasal quadrant in patients with POAG and HM, compared to patients with only HM. Measurements with OCT and GDxVCC were well-correlated, and both modalities detected RNFL thickness changes. However, GDxVCC was better than OCT in detecting POAG in HM patients.
Dada, Tanuj; Behera, Geeta; Agarwal, Anand; Kumar, Sanjeev; Sihota, Ramanjit; Panda, Anita
2010-01-01
To study the effect of cataract extraction on the retinal nerve fiber layer (RNFL) thickness, and assessment by scanning laser polarimetry (SLP), with variable corneal compensation (GDx VCC), at the glaucoma service of a tertiary care center in North India. Thirty-two eyes of 32 subjects were enrolled in the study. The subjects underwent RNFL analysis by SLP (GDx VCC) before undergoing phacoemulsification cataract extraction with intraocular lens (IOL) implantation (Acrysof SA 60 AT) four weeks following cataract surgery. The RNFL thickness parameters evaluated both before and after surgery included temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and nerve fiber index (NFI). The mean age of subjects was 57.6 +/- 11.7 years (18 males, 14 females). Mean TSNIT average thickness (microm) pre- and post-cataract surgery was 49.2 +/- 14.1 and 56.5 +/- 7.6 ( P = 0.001). There was a statistically significant increase in RNFL thickness parameters (TSNIT average, superior average, and inferior average) and decrease in NFI post-cataract surgery as compared to the baseline values. Mean NFI pre- and post-cataract surgery was 41.3 +/- 15.3 and 21.6 +/- 11.8 ( P = 0.001). Measurement of RNFL thickness parameters by scanning laser polarimetry is significantly altered following cataract surgery. Post the cataract surgery, a new baseline needs to be established for assessing the longitudinal follow-up of a glaucoma patient. The presence of cataract may lead to an underestimation of the RNFL thickness, and this should be taken into account when analyzing progression in a glaucoma patient.
Ganglion cell complex scan in the early prediction of glaucoma.
Ganekal, S
2012-01-01
To compare the macular ganglion cell complex (GCC) with peripapillary retinal fiber layer (RNFL) thickness map in glaucoma suspects and patients. Forty participants (20 glaucoma suspects and 20 glaucoma patients) were enrolled. Macular GCC and RNFL thickness maps were performed in both eyes of each participant in the same visit. The sensitivity and specificity of a color code less than 5% (red or yellow) for glaucoma diagnosis were calculated. Standard Automated Perimetry was performed with the Octopus 3.1.1 Dynamic 24-2 program. The statistical analysis was performed with the SPSS 10.1 (SPSS Inc. Chicago, IL, EUA). Results were expressed as mean +/- standard deviation and a p value of 0.05 or less was considered significant. Provide absolute numbers of these findings with their units of measurement. There was a statistically significant difference in average RNFL thickness (p=0.004), superior RNFL thickness (p=0.006), inferior RNFL thickness (p=0.0005) and average GCC (p=0.03) between the suspects and glaucoma patients. There was no difference in optic disc area (p=0.35) and vertical cup/disc ratio (p=0.234) in both groups. While 38% eyes had an abnormal GCC and 13% had an abnormal RNFL thickness in the glaucoma suspect group, 98% had an abnormal GCC and 90% had an abnormal RNFL thickness in the glaucoma group. The ability to diagnose glaucoma with macular GCC thickness is comparable to that with peripapillary RNFL thickness . Macular GCC thickness measurements may be a good alternative or a complementary measurement to RNFL thickness assessment in the clinical evaluation of glaucoma. © NEPjOPH.
Aydogan, Tuğba; Akçay, BetÜl İlkay Sezgin; Kardeş, Esra; Ergin, Ahmet
2017-11-01
The objective of this study is to evaluate the diagnostic ability of retinal nerve fiber layer (RNFL), macular, optic nerve head (ONH) parameters in healthy subjects, ocular hypertension (OHT), preperimetric glaucoma (PPG), and early glaucoma (EG) patients, to reveal factors affecting the diagnostic ability of spectral domain-optical coherence tomography (SD-OCT) parameters and risk factors for glaucoma. Three hundred and twenty-six eyes (89 healthy, 77 OHT, 94 PPG, and 66 EG eyes) were analyzed. RNFL, macular, and ONH parameters were measured with SD-OCT. The area under the receiver operating characteristic curve (AUC) and sensitivity at 95% specificity was calculated. Logistic regression analysis was used to determine the glaucoma risk factors. Receiver operating characteristic regression analysis was used to evaluate the influence of covariates on the diagnostic ability of parameters. In PPG patients, parameters that had the largest AUC value were average RNFL thickness (0.83) and rim volume (0.83). In EG patients, parameter that had the largest AUC value was average RNFL thickness (0.98). The logistic regression analysis showed average RNFL thickness was a risk factor for both PPG and EG. Diagnostic ability of average RNFL and average ganglion cell complex thickness increased as disease severity increased. Signal strength index did not affect diagnostic abilities. Diagnostic ability of average RNFL and rim area increased as disc area increased. When evaluating patients with glaucoma, patients at risk for glaucoma, and healthy controls RNFL parameters deserve more attention in clinical practice. Further studies are needed to fully understand the influence of covariates on the diagnostic ability of OCT parameters.
Reduced retinal nerve fiber layer (RNFL) thickness in ALS patients: a window to disease progression.
Rohani, Mohammad; Meysamie, Alipasha; Zamani, Babak; Sowlat, Mohammad Mahdi; Akhoundi, Fahimeh Haji
2018-04-30
To assess RNFL thickness in ALS patients and compare it to healthy controls, and to detect possible correlations between RNFL thickness in ALS patients and disease severity and duration. Study population consisted of ALS patients and age- and sex-matched controls. We used the revised ALS functional rating scale (ALSFRS-R) as a measure of disease severity. RNFL thickness in the four quadrants were measured with a spectral domain OCT (Topcon 3D, 2015). We evaluated 20 ALS patients (40 eyes) and 25 healthy matched controls. Average RNFL thickness in ALS patients was significantly reduced compared to controls (102.57 ± 13.46 compared to 97.11 ± 10.76, p 0.04). There was a significant positive correlation between the functional abilities of the patients based on the ALSFRS-R and average RNFL thickness and also RNFL thickness in most quadrants. A linear regression analysis proved that this correlation was independent of age. In ALS patients, RNFL thickness in the nasal quadrant of the left eyes was significantly reduced compared to the corresponding quadrant in the right eyes even after adjustment for multiplicity (85.80 ± 23.20 compared to 96.80 ± 16.96, p = 0.008). RNFL thickness in ALS patients is reduced compared to healthy controls. OCT probably could serve as a marker of neurodegeneration and progression of the disease in ALS patients. RNFL thickness is different among the right and left eyes of ALS patients pointing to the fact that asymmetric CNS involvement in ALS is not confined to the motor system.
Ability of Cirrus™ HD-OCT Optic Nerve Head Parameters to Discriminate Normal from Glaucomatous Eyes
Mwanza, Jean-Claude; Oakley, Jonathan D; Budenz, Donald L; Anderson, Douglas R
2010-01-01
Purpose To determine the ability of optic nerve head (ONH) parameters measured with spectral domain Cirrus™ HD-OCT to discriminate between normal and glaucomatous eyes and to compare them to the discriminating ability of peripapillary retinal nerve fiber layer (RNFL) thickness measurements performed with Cirrus™ HD-OCT. Design Evaluation of diagnostic test or technology. Participants Seventy-three subjects with glaucoma and one hundred and forty-six age-matched normal subjects. Methods Peripapillary ONH parameters and RNFL thickness were measured in one randomly selected eye of each participant within a 200×200 pixel A-scan acquired with Cirrus™ HD-OCT centered on the ONH. Main Outcome Measures ONH topographic parameters, peripapillary RNFL thickness, and the area under receiver operating characteristic curves (AUCs). Results For distinguishing normal from glaucomatous eyes, regardless of disease stage, the six best parameters (expressed as AUC) were vertical rim thickness (VRT, 0.963), rim area (RA, 0.962), RNFL thickness at clock-hour 7 (0.957), RNFL thickness of the inferior quadrant (0.953), vertical cup-to-disc ratio (VCDR, 0.951) and average RNFL thickness (0.950). The AUC for distinguishing between normal and eyes with mild glaucoma was greatest for RNFL thickness of clock-hour 7 (0.918), VRT (0.914), RA (0.912), RNFL thickness of inferior quadrant (0.895), average RNFL thickness (0.893) and VCDR (0.890). There were no statistically significant differences between AUCs for the best ONH parameters and RNFL thickness measurements (p > 0.05). Conclusions Cirrus™ HD-OCT ONH parameters are able to discriminate between eyes that are normal from those with glaucoma or even mild glaucoma. There is no difference in the ability of ONH parameters and RNFL thickness measurement, as measured with Cirrus™ OCT, to distinguish between normal and glaucomatous eyes. PMID:20920824
Sezgin Akcay, Betul Ilkay; Gunay, Betul Onal; Kardes, Esra; Unlu, Cihan; Ergin, Ahmet
2017-01-01
To assess the effect of low, moderate, and high myopia on the thickness of the retinal nerve fiber layer (RNFL) and Ganglion cell complex (GCC) measured by Spectral Domain Optical Coherence Tomography (SD-OCT) in non-glaucomatous subjects. The subjects were divided into three groups: low (n = 81, 35.6%), moderate (n = 79, 34.8%), and highly myopic eyes (n = 67, 29.5%). The RNFL thickness profile, including the average, superior, nasal, inferior, and temporal quadrant and each of the eight directional thicknesses, was measured. GCC parameters, including the average, superior, and inferior values, the focal loss volume (FLV), and the global loss volume (GLV), were measured. The correlation between the OCT measurements and the axial length was evaluated. The average, superior, inferior, and nasal RNFL thicknesses of low and moderate myopic eyes were found to be significantly higher than those of highly myopic eyes. The temporal RNFL thicknesses were not different among the three groups. The average, superior, and inferior ganglion cell complex values of low and moderate myopic eyes were significantly higher than those of highly myopic eyes. The FLV and GLV of low and moderate myopic eyes were significantly higher than those of highly myopic eyes (p = 0.001 for all). In the moderate and high myopia groups, the average RNFL thickness and GCC thickness were both negatively correlated with the axial length. Highly myopic subjects tend to have thinner RNFL and GCC thicknesses than subjects with low and moderate myopia.
Shin, Hye-Young; Park, Hae-Young Lopilly; Jung, Kyoung-In; Choi, Jin-A; Park, Chan Kee
2014-01-01
To determine whether the ganglion cell-inner plexiform layer (GCIPL) or circumpapillary retinal nerve fiber layer (cpRNFL) is better at distinguishing eyes with early glaucoma from normal eyes on the basis of the the initial location of the visual field (VF) damage. Retrospective, observational study. Eighty-four patients with early glaucoma and 43 normal subjects were enrolled. The patients with glaucoma were subdivided into 2 groups according to the location of VF damage: (1) an isolated parafoveal scotoma (PFS, N = 42) within 12 points of a central 10 degrees in 1 hemifield or (2) an isolated peripheral nasal step (PNS, N = 42) within the nasal periphery outside 10 degrees of fixation in 1 hemifield. All patients underwent macular and optic disc scanning using Cirrus high-definition optical coherence tomography (Carl Zeiss Meditec, Dublin, CA). The GCIPL and cpRNFL thicknesses were compared between groups. Areas under the receiver operating characteristic curves (AUCs) were calculated. Comparison of diagnostic ability using AUCs. The average and minimum GCIPL of the PFS group were significantly thinner than those of the PNS group, whereas there was no significant difference in the average retinal nerve fiber layer (RNFL) thickness between the 2 groups. The AUCs of the average (0.962) and minimum GCIPL (0.973) thicknesses did not differ from that of the average RNFL thickness (0.972) for discriminating glaucomatous changes between normal and all glaucoma eyes (P =0.566 and 0.974, respectively). In the PFS group, the AUCs of the average (0.988) and minimum GCIPL (0.999) thicknesses were greater than that of the average RNFL thickness (0.961, P =0.307 and 0.125, respectively). However, the AUCs of the average (0.936) and minimum GCIPL (0.947) thicknesses were lower than that of the average RNFL thickness (0.984) in the PNS group (P =0.032 and 0.069, respectively). The GCIPL parameters were more valuable than the cpRNFL parameters for detecting glaucoma in eyes with parafoveal VF loss, and the cpRNFL parameters were better than the GCIPL parameters for detecting glaucoma in eyes with peripheral VF loss. Clinicians should know that the diagnostic capability of macular GCIPL parameters depends largely on the location of the VF loss. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Dada, Tanuj; Behera, Geeta; Agarwal, Anand; Kumar, Sanjeev; Sihota, Ramanjit; Panda, Anita
2010-01-01
Purpose: To study the effect of cataract extraction on the retinal nerve fiber layer (RNFL) thickness, and assessment by scanning laser polarimetry (SLP), with variable corneal compensation (GDx VCC), at the glaucoma service of a tertiary care center in North India. Materials and Methods: Thirty-two eyes of 32 subjects were enrolled in the study. The subjects underwent RNFL analysis by SLP (GDx VCC) before undergoing phacoemulsification cataract extraction with intraocular lens (IOL) implantation (Acrysof SA 60 AT) four weeks following cataract surgery. The RNFL thickness parameters evaluated both before and after surgery included temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and nerve fiber index (NFI). Results: The mean age of subjects was 57.6 ± 11.7 years (18 males, 14 females). Mean TSNIT average thickness (μm) pre- and post-cataract surgery was 49.2 ± 14.1 and 56.5 ± 7.6 (P = 0.001). There was a statistically significant increase in RNFL thickness parameters (TSNIT average, superior average, and inferior average) and decrease in NFI post-cataract surgery as compared to the baseline values. Mean NFI pre- and post-cataract surgery was 41.3 ± 15.3 and 21.6 ± 11.8 (P = 0.001). Conclusions: Measurement of RNFL thickness parameters by scanning laser polarimetry is significantly altered following cataract surgery. Post the cataract surgery, a new baseline needs to be established for assessing the longitudinal follow-up of a glaucoma patient. The presence of cataract may lead to an underestimation of the RNFL thickness, and this should be taken into account when analyzing progression in a glaucoma patient. PMID:20689193
Quelly, Amanda; Cheng, Han; Laron, Michal; Schiffman, Jade S.; Tang, Rosa A.
2010-01-01
Purpose To compare optical coherence tomography (OCT) and scanning laser polarimetry (GDx) measurements of the retinal nerve fiber layer (RNFL) in multiple sclerosis (MS) patients with and without optic neuritis (ON). Methods OCT and GDx were performed on 68 MS patients. Qualifying eyes were divided into two groups: 51 eyes with an ON history ≥ 6 months prior (ON eyes), and 65 eyes with no history of ON (non-ON eyes). Several GDx and OCT parameters and criteria were used to define an eye as abnormal, for example, GDx nerve fiber indicator (NFI) above 20 or 30, OCT average RNFL thickness and GDx temporal-superior-nasal-inferior-temporal average (TSNIT) below 5% or 1% of the instruments’ normative database. Agreement between OCT and GDx parameters was reported as percent of observed agreement, along with the AC1 statistic. Linear regression analyses were used to examine the relationship between OCT average RNFL thickness and GDx NFI and TSNIT. Results All OCT and GDx measurements showed significantly more RNFL damage in ON than in non-ON eyes. Agreement between OCT and GDx parameters ranged from 69–90% (AC1 0.37–0.81) in ON eyes, and 52–91% (AC1 = 0.21–0.90) in non-ON eyes. Best agreement was observed between OCT average RNFL thickness (P < 0.01) and NFI (>30) in ON eyes (90%, AC1 = 0.81), and between OCT average RNFL thickness (P < 0.01) and GDx TSNIT average (P < 0.01) in non-ON eyes (91%, AC1 = 0.90). In ON eyes, the OCT average RNFL thickness showed good linear correlation with NFI (R2 = 0.69, P < 0.0001) and TSNIT (R2 = 0.55, P < 0.0001). Conclusions OCT and GDx show good agreement and can be useful in detecting RNFL loss in MS/ON eyes. PMID:20495500
Aydoğan, Tuğba; Akçay, Betül İlkay Sezgin; Kardeş, Esra; Ergin, Ahmet
2017-01-01
Purpose: The objective of this study is to evaluate the diagnostic ability of retinal nerve fiber layer (RNFL), macular, optic nerve head (ONH) parameters in healthy subjects, ocular hypertension (OHT), preperimetric glaucoma (PPG), and early glaucoma (EG) patients, to reveal factors affecting the diagnostic ability of spectral domain-optical coherence tomography (SD-OCT) parameters and risk factors for glaucoma. Methods: Three hundred and twenty-six eyes (89 healthy, 77 OHT, 94 PPG, and 66 EG eyes) were analyzed. RNFL, macular, and ONH parameters were measured with SD-OCT. The area under the receiver operating characteristic curve (AUC) and sensitivity at 95% specificity was calculated. Logistic regression analysis was used to determine the glaucoma risk factors. Receiver operating characteristic regression analysis was used to evaluate the influence of covariates on the diagnostic ability of parameters. Results: In PPG patients, parameters that had the largest AUC value were average RNFL thickness (0.83) and rim volume (0.83). In EG patients, parameter that had the largest AUC value was average RNFL thickness (0.98). The logistic regression analysis showed average RNFL thickness was a risk factor for both PPG and EG. Diagnostic ability of average RNFL and average ganglion cell complex thickness increased as disease severity increased. Signal strength index did not affect diagnostic abilities. Diagnostic ability of average RNFL and rim area increased as disc area increased. Conclusion: When evaluating patients with glaucoma, patients at risk for glaucoma, and healthy controls RNFL parameters deserve more attention in clinical practice. Further studies are needed to fully understand the influence of covariates on the diagnostic ability of OCT parameters. PMID:29133640
Yang, Zi-Jiao; Wei, Jing; Mao, Cheng-Jie; Zhang, Jin-Ru; Chen, Jing; Ji, Xiao-Yan; Liu, Jun-Yi; Shen, Yun; Xiong, Kang-Ping; Huang, Jun-Ying; Yang, Ya-Ping; Liu, Chun-Feng
2016-12-01
Retinal nerve fiber layer (RNFL) thinning occurs in Parkinson's disease (PD) and other neurodegenerative diseases. Idiopathic RBD (iRBD) is a well-established prodromal hallmark of synucleinopathies and occurs secondary to many neurodegenerative diseases, including PD. The aim of this study is to determine whether or not retinal structures are altered with the onset of rapid eye movement (REM) sleep behavior disorders (RBD). In all, a total of 63 patients with PD, 14 patients with idiopathic RBD, and 26 sex- and age-matched healthy controls were enrolled and underwent optical coherence tomography measurements (HD-OCT (Zeiss) ) for the average and every quadrant of RNFL thickness. The REM Sleep Behavior Disorder Screening Questionnaire (RBDSQ) was used to classify PD patients with clinically probable RBD (PD + pRBD) or without probable RBD (PD - pRBD). Patients with iRBD were identified by polysomnography. For patients with RBD (idiopathic or secondary to PD), we found a significant decrease in RNFL thickness compared with groups without RBD (PD - pRBD and healthy controls) (all p < 0.05). Average RNFL thickness in patients with iRBD is significantly thinner than in healthy controls (p < 0.05). In PD, the average RNFL thickness was dramatically thinner in the PD + pRBD group than the PD - pRBD group (p < 0.005). Compared with healthy controls, RNFL thickness was slightly thinner in the drug-naive PD group but not the PD group with drug treatment. Multiple linear regression analysis showed that RBDSQ score was negatively associated with average and inferior RNFL variation in PD (all p < 0.005). The findings show that RNFL was slightly but significantly thinner in idiopathic RBD. In PD, RNFL thickness may vary depending on the presence of RBD.
Schuster, Alexander Karl-Georg; Fischer, Joachim Ernst; Vossmerbaeumer, Christine; Vossmerbaeumer, Urs
2016-10-01
Optical coherence tomography (OCT) allows quantitative image analysis of retinal tissue in vivo. Peripapillary retinal nerve fiber layer (pRNFL) thickness is widely used for evaluation of retinal nerve fiber rarefaction in several optic neuropathies. This study evaluates associations of pRNFL thickness in healthy adult subjects in order to evaluate influencing factors. A cross-sectional study was performed in a working-age population. Only eyes without detectable ocular pathologies were included in the analysis. Among analyzed systemic cardiovascular parameters were age, gender, body-mass index, mean arterial blood pressure, HbA1c, high- and low-density-lipoproteins, and triglycerides. A comprehensive ophthalmological examination including refraction, tonometry, keratometry, and central corneal thickness measurmentwas performed. In addition, pRNFL thickness was imaged by spectral-domain OCT. Univariable and multivariable associations of pRNFL thickness in all four quadrants and on average with systemic and ocular parameters were calculated using a generalized estimating equation model. Three hundred and six subjects were included. pRNFL thickness measurements showed a significant association with spherical equivalent: pRNFL thickness decreased with increasing myopia in all quadrants (multivariable regression coefficients Beta: superior: 1.16, 95 % CI [0.62;1.71], p < 0.001; temporal: 0.87, [0.33;1.41], p = 0.001; inferior: 1.80, [1.18;2.42], p < 0.001; nasal: 2.60, [2.01;3.20], p < 0.001) and on average (1.51, [1.20;1.82], p < 0.001). A thicker central cornea thickness was related to lower pRNFL in the superior (-0.05, [-0.10; -0.01], p = 0.01), the inferior quadrant (-0.05, [-0.10;0.00], p = 0.03) and on average (-0.04, [-0.07; -0.01], p = 0.02). All other parameters were not associated. Our findings highlight the importance of refraction when evaluating pRNFL thickness and its independence from other systemic parameters.
Lee, Ju-Yeun; Han, Jinu; Seo, Jeong Gi; Park, Kyung-Ah; Oh, Sei Yeul
2018-04-26
To evaluate the diagnostic value of macular ganglion cell-inner plexiform layer (mGCIPL) thickness versus peripapillary retinal nerve fibre layer (pRNFL) thickness for the early detection of ethambutol-induced optic neuropathy (EON). Twenty-eight eyes of 15 patients in the EON group and 100 eyes of 53 healthy subjects in the control group were included. All patients with EON demonstrated the onset of visual symptoms within 3 weeks. Diagnostic power for pRNFL and mGCIPL thicknesses measured by Cirrus spectral-domain optical coherence tomography was assessed by area under the receiver operating characteristic (AUROC) curves and sensitivity. All of the mGCIPL thickness measurements were thinner in the EON group than in the control group in early EON (p<0.001). All of pRNFL thicknesses except inferior RNFL showed AUROC curves above 0.5, and all of the mGCIPL thicknesses showed AUROC curves above 0.5. The AUROC of the average mGCIPL (0.812) thickness was significantly greater than that of the average pRNFL (0.507) thickness (p<0.001). Of all the mGCIPL-related parameters considered, the minimum thickness showed the greatest AUROC value (0.863). The average mGCIPL thickness showed a weak correlation with visual field pattern standard deviations (r 2 =0.158, p<0.001). In challenging cases of EON, the mGCIPL thickness has better diagnostic performance in detecting early-onset EON as compared with using pRNFL thickness. Among the early detection ability of mGCIPL thickness, minimum GCIPL thickness has high diagnostic ability. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Kalyani, Partho S.; Holland, Gary N.; Fawzi, Amani A.; Arantes, Tiago E.F.; Yu, Fei; Sadun, Alfredo A.
2014-01-01
Purpose To investigate relationships between contrast sensitivity (CS), color vision, and retinal nerve fiber layer (RNFL) among people with human immunodeficiency virus (HIV) infection; to evaluate the effect of time since diagnosis of HIV infection on RNFL thickness. Design Noninterventional cross-sectional study. Methods We evaluated 102 eyes of 57 HIV-infected individuals without ocular opportunistic infections. Peripapillary RNFL thickness was determined with spectraldomain optical coherence tomography in 4 quadrants. CS was measured with the Pelli-Robson technique (expressed as logCS); color vision was measured with the Lanthony desaturated 15-hue technique (expressed as color confusion index [C-index], with higher scores indicating worse color vision). Correlations between values were assessed using Spearman correlation coefficients. Results Median RNFL thickness (average of 4 quadrants) was 102.9 μm (range, 75.0–134.7 μm). Median logCS was 1.90 (range, 1.25–1.95). Median C-index was 1.58 (range, 0.96–4.07). Temporal RNFL thickness was correlated with logCS (r = 0.295, P = .003) and C-index (r = −0.338, P = .0005). Time since diagnosis of HIV infection was shorter for those with thick average RNFL than for those with thin average RNFL (P = .18). Conclusions Both worse CS and worse color vision are correlated with thinning of the temporal RNFL, with possible threshold effects. Increased prevalences of abnormal CS and abnormal color vision in this population are therefore likely attributable to neuroretinal compromise. This pattern of structural and functional losses may reflect preferential damage to small-caliber axons in the maculopapillary bundle, possibly associated with mitochondrial dysfunction, providing a potential disease mechanism for HIV-associated “neuroretinal disorder.” PMID:22245459
Hammel, Naama; Belghith, Akram; Weinreb, Robert N; Medeiros, Felipe A; Mendoza, Nadia; Zangwill, Linda M
2017-06-01
To compare the rates of circumpapillary retinal nerve fiber layer (RNFL) and macular retinal ganglion cell-inner plexiform layer (GCIPL) change over time in healthy and glaucoma eyes. Cohort study. The rates of circumpapillary RNFL and macular GCIPL loss in 28 healthy subjects and 97 glaucoma subjects from the Diagnostic Innovations in Glaucoma Study (DIGS) were compared using mixed-effects models. The median follow-up time and number of visits were 1.7 years and 6 visits and 3.2 years and 7 visits for healthy and glaucoma eyes, respectively. Significant rates of loss of both global circumpapillary RNFL and average macular GCIPL thickness were detectable in early and moderate glaucoma eyes; in severe glaucoma eyes, rates of average macular GCIPL loss were significant, but rates of global circumpapillary RNFL loss were not. In glaucoma eyes, mean rates of global circumpapillary RNFL thickness change (-0.98 μm/year [95% confidence interval (CI), -1.20 to -0.76]) and normalized global circumpapillary RNFL change (-1.7%/year [95% CI, -2.1 to -1.3]) were significantly faster than average macular GCIPL change (-0.57 μm/year [(95% CI, -0.73 to -0.41]) and normalized macular GCIPL change (-1.3%/year [95% CI, -1.7 to -0.9]). The rates of global and inferior RNFL change were weakly correlated with global and inferior macular GCIPL change (r ranges from 0.16 to 0.23, all P < .05). In this cohort, the rate of circumpapillary RNFL thickness change was faster than macular GCIPL change for glaucoma eyes. Global circumpapillary RNFL thickness loss was detectable in early and moderate glaucoma, and average macular GCIPL thickness loss was detectable in early, moderate, and severe glaucoma, suggesting that structural changes can be detected in severe glaucoma. Copyright © 2017 Elsevier Inc. All rights reserved.
Retinal nerve fiber layer thickness in normals measured by spectral domain OCT.
Bendschneider, Delia; Tornow, Ralf P; Horn, Folkert K; Laemmer, Robert; Roessler, Christopher W; Juenemann, Anselm G; Kruse, Friedrich E; Mardin, Christian Y
2010-09-01
To determine normal values for peripapillary retinal nerve fiber layer thickness (RNFL) measured by spectral domain Optical Coherence Tomography (SOCT) in healthy white adults and to examine the relationship of RNFL with age, gender, and clinical variables. The peripapillary RNFL of 170 healthy patients (96 males and 74 females, age 20 to 78 y) was imaged with a high-resolution SOCT (Spectralis HRA+OCT, Heidelberg Engineering) in an observational cross-sectional study. RNFL thickness was measured around the optic nerve head using 16 automatically averaged, consecutive circular B-scans with 3.4-mm diameter. The automatically segmented RNFL thickness was divided into 32 segments (11.25 degrees each). One randomly selected eye per subject entered the study. Mean RNFL thickness in the study population was 97.2 ± 9.7 μm. Mean RNFL thickness was significantly negatively correlated with age (r = -0.214, P = 0.005), mean RNFL decrease per decade was 1.90 μm. As age dependency was different in different segments, age-correction of RNFL values was made for all segments separately. Age-adjusted RNFL thickness showed a significant correlation with axial length (r = -0.391, P = 0.001) and with refractive error (r = 0.396, P<0.001), but not with disc size (r = 0.124). Normal RNFL results with SOCT are comparable to those reported with time-domain OCT. In accordance with the literature on other devices, RNFL thickness measured with SOCT was significantly correlated with age and axial length. For creating a normative database of SOCT RNFL values have to be age adjusted.
Zhang, Zhihua; Yang, Xiaolu; Jin, Huiyi; Qu, Yuan; Zhang, Yuan; Liu, Kun; Xu, Xun
2016-12-06
Conbercept is a recombinant fusion protein with high affinity for all vascular endothelial growth factor isoforms and placental growth factor. The repeated intravitreal injection of conbercept may cause intraocular pressure (IOP) fluctuations and long-term suppression of neurotrophic cytokines, which could lead to retinal nerve fiber layer (RNFL) damage. This retrospective fellow-eye controlled study included 98 eyes of 49 patients. The changes in IOP and RNFL thickness as well as the correlation between RNFL changes and associated factors were evaluated. The IOP value between the baseline and the last follow-up visit in the injection group and the IOP value of the last follow-up visit between the injection and non-injection groups were not significantly different (p = 0.452 and 0.476, respectively). The global average thickness of the RNFL (μm) in the injection group decreased from 108.9 to 106.1; however, the change was not statistically significant (p = 0.118). No significant difference in the average RNFL thickness was observed at the last follow-up visit between the injection and non-injection groups (p = 0.821). The type of disease was the only factor associated with RNFL thickness changes. In conclusion, repeated intravitreal injections with 0.05 mL conbercept revealed an excellent safety profile for RNFL thickness, although short-term IOP changes were observed.
Perez, Claudio I; Chansangpetch, Sunee; Thai, Andy; Nguyen, Anh-Hien; Nguyen, Anwell; Mora, Marta; Nguyen, Ngoc; Lin, Shan C
2018-06-05
Evaluate the distribution and the color probability codes of the peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy Vietnamese population and compare them with the original color-codes provided by the Cirrus spectral domain OCT. Cross-sectional study. We recruited non-glaucomatous Vietnamese subjects and constructed a normative database for peripapillary RNFL and macular GCIPL thickness. The probability color-codes for each decade of age were calculated. We evaluated the agreement with Kappa coefficient (κ) between OCT color probability codes with Cirrus built-in original normative database and the Vietnamese normative database. 149 eyes of 149 subjects were included. The mean age of enrollees was 60.77 (±11.09) years, with a mean spherical equivalent of +0.65 (±1.58) D and mean axial length of 23.4 (±0.87) mm. Average RNFL thickness was 97.86 (±9.19) microns and average macular GCIPL was 82.49 (±6.09) microns. Agreement between original and adjusted normative database for RNFL was fair for average and inferior quadrant (κ=0.25 and 0.2, respectively); and good for other quadrants (range: κ=0.63-0.73). For macular GCIPL κ agreement ranged between 0.39 and 0.69. After adjusting with the normative Vietnamese database, the percent of yellow and red color-codes increased significantly for peripapillary RNFL thickness. Vietnamese population has a thicker RNFL in comparison with Cirrus normative database. This leads to a poor color-code agreement in average and inferior quadrant between the original and adjusted database. These findings should encourage to create a peripapillary RNFL normative database for each ethnicity.
Aleman, Tomas S.; Huang, Jiayan; Garrity, Sean T.; Carter, Stuart B.; Aleman, Wendy D.; Ying, Gui-shuang; Tamhankar, Madhura A.
2014-01-01
Purpose To study the relationship between the appearance of the optic nerve and the retinal nerve fiber layer (RNFL) thickness determined by spectral domain optical coherence tomography (OCT). Methods Records from patients with spectral domain-OCT imaging in a neuro-ophthalmology practice were reviewed. Eyes with glaucoma/glaucoma suspicion, macular/optic nerve edema, pseudophakia, and with refractive errors > 6D were excluded. Optic nerve appearance by slit lamp biomicroscopy was related to the RNFL thickness by spectral domain-OCT and to visual field results. Results Ninety-one patients (176 eyes; mean age: 49 ± 15 years) were included. Eighty-three eyes (47%) showed optic nerve pallor; 89 eyes (50.6%) showed RNFL thinning (sectoral or average peripapillary). Average peripapillary RNFL thickness in eyes with pallor (mean ± SD = 76 ± 17 μm) was thinner compared to eyes without pallor (91 ± 14 μm, P < 0.001). Optic nerve pallor predicted RNFL thinning with a sensitivity of 69% and a specificity of 75%. Optic nerve appearance predicted RNFL thinning (with a sensitivity and specificity of 81%) when RNFL had thinned by ∼ 40%. Most patients with pallor had RNFL thinning with (66%) or without (25%) visual field loss; the remainder had normal RNFL and fields (5%) or with visual field abnormalities (4%). Conclusions Optic nerve pallor as a predictor of RNFL thinning showed fair sensitivity and specificity, although it is optimally sensitive/specific only when substantial RNFL loss has occurred. Translational Relevance Finding an acceptable relationship between the optic nerve appearance by ophthalmoscopy and spectral domain-OCT RNFL measures will help the clinician's interpretation of the information provided by this technology, which is gaining momentum in neuro-ophthalmic research. PMID:25374773
Likelihood Ratios for Glaucoma Diagnosis Using Spectral Domain Optical Coherence Tomography
Lisboa, Renato; Mansouri, Kaweh; Zangwill, Linda M.; Weinreb, Robert N.; Medeiros, Felipe A.
2014-01-01
Purpose To present a methodology for calculating likelihood ratios for glaucoma diagnosis for continuous retinal nerve fiber layer (RNFL) thickness measurements from spectral domain optical coherence tomography (spectral-domain OCT). Design Observational cohort study. Methods 262 eyes of 187 patients with glaucoma and 190 eyes of 100 control subjects were included in the study. Subjects were recruited from the Diagnostic Innovations Glaucoma Study. Eyes with preperimetric and perimetric glaucomatous damage were included in the glaucoma group. The control group was composed of healthy eyes with normal visual fields from subjects recruited from the general population. All eyes underwent RNFL imaging with Spectralis spectral-domain OCT. Likelihood ratios for glaucoma diagnosis were estimated for specific global RNFL thickness measurements using a methodology based on estimating the tangents to the Receiver Operating Characteristic (ROC) curve. Results Likelihood ratios could be determined for continuous values of average RNFL thickness. Average RNFL thickness values lower than 86μm were associated with positive LRs, i.e., LRs greater than 1; whereas RNFL thickness values higher than 86μm were associated with negative LRs, i.e., LRs smaller than 1. A modified Fagan nomogram was provided to assist calculation of post-test probability of disease from the calculated likelihood ratios and pretest probability of disease. Conclusion The methodology allowed calculation of likelihood ratios for specific RNFL thickness values. By avoiding arbitrary categorization of test results, it potentially allows for an improved integration of test results into diagnostic clinical decision-making. PMID:23972303
Nakatani, Yusuke; Higashide, Tomomi; Ohkubo, Shinji; Sugiyama, Kazuhisa
2014-10-23
We investigated the influences of the inner retinal sublayers and analytical areas in macular scans by spectral-domain optical coherence tomography (OCT) on the diagnostic ability of early glaucoma. A total of 64 early (including 24 preperimetric) glaucomatous and 40 normal eyes underwent macular and peripapillary retinal nerve fiber layer (pRNFL) scans (3D-OCT-2000). The area under the receiver operating characteristics (AUC) for glaucoma diagnosis was determined from the average thickness of the total 100 grids (6 × 6 mm), central 44 grids (3.6 × 4.8 mm), and peripheral 56 grids (outside of the 44 grids), and for each macular sublayer: macular RNFL (mRNFL), ganglion cell layer plus inner plexiform layer (GCL/IPL), and mRNFL plus GCL/IPL (ganglion cell complex [GCC]). Correlation of OCT parameters with visual field parameters was evaluated by Spearman's rank correlation coefficients (rs). The GCC-related parameters had a significantly larger AUC (0.82-0.97) than GCL/IPL (0.81-0.91), mRNFL-related parameters (0.72-0.94), or average pRNFL (0.88) in more than half of all comparisons. The central 44 grids had a significantly lower AUC than other analytical areas in GCC and mRNFL thickness. Conversely, the peripheral 56 grids had a significantly lower AUC than the 100 grids in GCL/IPL inferior thickness. Inferior thickness of GCC (rs, 0.45-0.49) and mRNFL (rs, 0.43-0.51) showed comparably high correlations with central visual field parameters to average pRNFL thickness (rs, 0.41, 0.47) even in the central 44 grids. The diagnostic ability of macular OCT parameters for early glaucoma differed by inner retinal sublayers and also by the analytical areas studied. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Diagnostic ability of macular ganglion cell-inner plexiform layer thickness in glaucoma suspects.
Xu, Xiaoyu; Xiao, Hui; Guo, Xinxing; Chen, Xiangxi; Hao, Linlin; Luo, Jingyi; Liu, Xing
2017-12-01
The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), and 225 normal eyes were included. GCIPL thickness (average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal), retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured using Cirrus high-definition optical coherence tomography (OCT) and compared. The diagnostic ability of OCT parameters was assessed by area under receiver operating characteristic curve (AUROC) in 3 distinguishing groups: normal eyes and eyes with early glaucoma, normal eyes and eyes with glaucoma regardless of disease stage, and nonglaucomatous eyes (normal eyes, eyes with OHT, and enlarged C/D) and early glaucomatous eyes.Glaucomatous eyes showed a significant reduction in GCIPL thickness compared with nonglaucomatous eyes. In all 3 distinguishing groups, best-performing parameters of GCIPL thickness, RNFL thickness, and ONH parameters were minimum GCIPL thickness (expressed in AUROC, 0.899, 0.952, and 0.900, respectively), average RNFL thickness (0.904, 0.953, and 0.892, respectively), and rim area (0.861, 0.925, and 0.824, respectively). There was no statistical significance of AUROC between minimum GCIPL thickness and average RNFL thickness (all P > .05).GCIPL thickness could discriminate early glaucoma from normal and glaucoma suspects with good sensitivity and specificity. The glaucoma diagnostic ability of GCIPL thickness was comparable to that of RNFL thickness. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Hong, Samin; Kim, Chan Yun; Lee, Won Seok; Seong, Gong Je
2010-01-01
To assess the reproducibility of the new spectral domain Cirrus high-definition optical coherence tomography (HD-OCT; Carl Zeiss Meditec, Dublin, CA, USA) for analysis of peripapillary retinal nerve fiber layer (RNFL) thickness in healthy eyes. Thirty healthy Korean volunteers were enrolled. Three optic disc cube 200 x 200 Cirrus HD-OCT scans were taken on the same day in discontinuous sessions by the same operator without using the repeat scan function. The reproducibility of the calculated RNFL thickness and probability code were determined by the intraclass correlation coefficient (ICC), coefficient of variation (CV), test-retest variability, and Fleiss' generalized kappa (kappa). Thirty-six eyes were analyzed. For average RNFL thickness, the ICC was 0.970, CV was 2.38%, and test-retest variability was 4.5 microm. For all quadrants except the nasal, ICCs were 0.972 or higher and CVs were 4.26% or less. Overall test-retest variability ranged from 5.8 to 8.1 microm. The kappa value of probability codes for average RNFL thickness was 0.690. The kappa values of quadrants and clock-hour sectors were lower in the nasal areas than in other areas. The reproducibility of Cirrus HD-OCT to analyze peripapillary RNFL thickness in healthy eyes was excellent compared with the previous reports for time domain Stratus OCT. For the calculated RNFL thickness and probability code, variability was relatively higher in the nasal area, and more careful analyses are needed.
Huang, David; Chopra, Vikas; Lu, Ake Tzu-Hui; Tan, Ou; Francis, Brian; Varma, Rohit
2012-01-01
Purpose. To determine the relationship between retinal nerve fiber layer (RNFL) thickness, optic disc size, and image magnification. Methods. The cohort consisted of 196 normal eyes of 101 participants in the Advanced Imaging for Glaucoma Study (AIGS), a multicenter, prospective, longitudinal study to develop advanced imaging technologies for glaucoma diagnosis. Scanning laser tomography was used to measure disc size. Optical coherence tomography (OCT) was used to perform circumpapillary RNFL thickness measurements using the standard fixed 3.46-mm nominal scan diameter. A theoretical model of magnification effects was developed to relate RNFL thickness (overall average) with axial length and magnification. Results. Multivariate regression showed no significant correlation between RNFL thickness and optic disc area (95% confidence interval [CI] = −0.9 to 4.1 μm/mm2, P = 0.21). Linear regression showed that RNFL thickness depended significantly on axial length (slope = −3.1 μm/mm, 95% CI = −4.9 to −1.3, P = 0.001) and age (slope = −0.3 μm/y, 95% CI = −0.5 to −0.2, P = 0.0002). The slope values agreed closely with the values predicted by the magnification model. Conclusions. There is no significant association between RNFL thickness and optic disc area. Previous publications that showed such an association may have been biased by the effect of axial length on fundus image magnification and, therefore, both measured RNFL thickness and apparent disc area. The true diameter of the circumpapillary OCT scan is larger for a longer eye (more myopic eye), leading to a thinner RNFL measurement. Adjustment of measured RNFL thickness by axial length, in addition to age, may lead to a tighter normative range and improve the detection of RNFL thinning due to glaucoma. PMID:22743319
Xu, WanWan; Kurup, Sudhi P; Fawzi, Amani A; Durbin, Mary K; Maumenee, Irene H; Mets, Marilyn B
2017-01-01
To report the distribution of macular and optic nerve topography in the eyes of individuals with Marfan syndrome aged 8-56 years using spectral domain optical coherence tomography (SD-OCT). Thirty-three patients with Marfan syndrome underwent a full eye examination including slit-lamp biomicroscopy, indirect ophthalmoscopy, and axial length measurement; and SD-OCT measurements of the retinal nerve fiber layer (RNFL) and macular thickness. For patients between the ages of 8 and 12 years, the average RNFL thickness is 98 ± 9 μm, the vertical cup to disc (C:D) ratio is 0.50 ± 0.10, the central subfield thickness (CST) is 274 ± 38 μm, and the macular volume is 10.3 ± 0.6 mm 3 . For patients between the ages of 13 and 17 years, the average RNFL is 86 ± 16 μm, the vertical C:D ratio is 0.35 ± 0.20, the CST is 259 ± 15 μm, and the macular volume is 10.1 ± 0.5 mm 3 . For patients 18 years or older, the average RNFL is 89 ± 12 μm, the vertical C:D ratio is 0.46 ± 0.18, the CST is 262 ± 20 μm, and the macular volume is 10.2 ± 0.4 mm 3 . When the average RNFL data are compared to a normative, age-adjusted database, 6 of 33 (18%) were thinner than the 5% limit. This study reports the distribution of SD-OCT data for patients with Marfan syndrome. Compared to a normative database, 18% of eyes with Marfan syndrome had RNFL thickness < 5% of the population.
Likelihood ratios for glaucoma diagnosis using spectral-domain optical coherence tomography.
Lisboa, Renato; Mansouri, Kaweh; Zangwill, Linda M; Weinreb, Robert N; Medeiros, Felipe A
2013-11-01
To present a methodology for calculating likelihood ratios for glaucoma diagnosis for continuous retinal nerve fiber layer (RNFL) thickness measurements from spectral-domain optical coherence tomography (spectral-domain OCT). Observational cohort study. A total of 262 eyes of 187 patients with glaucoma and 190 eyes of 100 control subjects were included in the study. Subjects were recruited from the Diagnostic Innovations Glaucoma Study. Eyes with preperimetric and perimetric glaucomatous damage were included in the glaucoma group. The control group was composed of healthy eyes with normal visual fields from subjects recruited from the general population. All eyes underwent RNFL imaging with Spectralis spectral-domain OCT. Likelihood ratios for glaucoma diagnosis were estimated for specific global RNFL thickness measurements using a methodology based on estimating the tangents to the receiver operating characteristic (ROC) curve. Likelihood ratios could be determined for continuous values of average RNFL thickness. Average RNFL thickness values lower than 86 μm were associated with positive likelihood ratios (ie, likelihood ratios greater than 1), whereas RNFL thickness values higher than 86 μm were associated with negative likelihood ratios (ie, likelihood ratios smaller than 1). A modified Fagan nomogram was provided to assist calculation of posttest probability of disease from the calculated likelihood ratios and pretest probability of disease. The methodology allowed calculation of likelihood ratios for specific RNFL thickness values. By avoiding arbitrary categorization of test results, it potentially allows for an improved integration of test results into diagnostic clinical decision making. Copyright © 2013. Published by Elsevier Inc.
Shin, Ji Soo
2017-01-01
Purpose The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. Methods This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. Results The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p < 0.001), whereas that of the retinal pigment epithelium at each follow-up decreased significantly from baseline (p < 0.001). The average thickness of the peripapillary RNFL increased significantly at one month (p < 0.001). This thickness subsequently recovered to 7.48 µm, and there were no significant changes at six or 12 months compared to baseline (p > 0.05). Conclusions Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. PMID:29022292
Shin, Ji Soo; Lee, Young Hoon
2017-12-01
The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p < 0.001), whereas that of the retinal pigment epithelium at each follow-up decreased significantly from baseline (p < 0.001). The average thickness of the peripapillary RNFL increased significantly at one month (p < 0.001). This thickness subsequently recovered to 7.48 μm, and there were no significant changes at six or 12 months compared to baseline (p > 0.05). Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. © 2017 The Korean Ophthalmological Society
Shi, Rui; Guo, Zhonglan; Wang, Feng; Li, Rong; Zhao, Lei; Lin, Rong
2018-02-01
To investigate the loss of retinal nerve fiber layer (RNFL) in type-2 diabetic patients with early-stage diabetic retinopathy (DR) and to identify potential risk factors accounting for these alterations. In this cross-sectional study, 158 type-2 diabetic patients were divided into three groups based on their DR status. RNFL thickness and other optic disc parameters were obtained by optical coherence tomography (OCT) and then compared among different groups. We investigated the potential association between RNFL loss and systemic risk factors for DR, including diabetes duration, body mass index (BMI), serum lipids, hemoglobin A1c (HbA1c) and albumin-creatinine ratio (ACR). One-way ANOVA was carried out to compare RNFL thickness among different groups, Pearson correlation and multivariate linear regression analysis were performed to determine potential risk factors related to RNFL thickness in these patients. There were significant differences in the average (F = 8.872, P = 0.003), superior (F = 8.769, P = 0.004), and inferior (F = 8.857, P = 0.003) RNFL thickness of both eyes among the groups, but no obvious difference in optic disc parameters was found. Diabetic duration, BMI, TG, High density lipoprotein cholesterol (HDL), HbA1c, and ACR were found negatively related to the RNFL thickness in both or single eye according to Pearson correlation analysis. After controlling for age, gender, and axis length (AL) in multivariate linear regression analysis, the diabetic duration was associated significantly with RNFL thickness of superior in both eye (right eye: p = 0.016, left eye: p = 0.024), BMI was related to the nasal quadrant of the right eye (p = 0.034), and TG was related to the inferior of the right eye (p = 0.037), HbA1c (p = 0.026) was associated significantly with the average RNFL thickness of the right eye. In addition, ACR was found negatively related to average (p = 0.042) and inferior quadrant (p = 0.014) of the left eye, respectively. RNFL loss might be the earliest structural change of retina in diabetic patients, and associated with diabetic duration, BMI, TG, HbA1c, and ACR. The conclusions of this study need to be proved by other well-matched and large-scale prospective clinical trials in the future, because the correlations discovered in our study were weak.
Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun
2016-07-03
BACKGROUND The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. MATERIAL AND METHODS Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. RESULTS The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). CONCLUSIONS GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients.
Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun
2016-01-01
Background The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. Material/Methods Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. Results The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). Conclusions GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients. PMID:27372909
Retinal Layers Measurements following Silicone Oil Tamponade for Retinal Detachment Surgery.
Jurišić, Darija; Geber, Mia Zorić; Ćavar, Ivan; Utrobičić, Dobrila Karlica
2017-12-19
This study aimed to investigate the influence of silicone oil on the retinal nerve fiber layer (RNFL) thickness in patients with primary rhegmatogenous retinal detachment who underwent vitreoretinal surgery. The study included 47 patients (eyes), who underwent a pars plana vitrectomy with the silicone oil tamponade. The control group included unoperated eye of all participants. Spectral-domain optical coherence tomography (SD-OCT) was used for the measurements of peripapilar and macular RNFL thickness. The average peripapillary RNFL thickness was significantly higher in the silicone oil filled eyes during endotamponade and after its removal. The eyes with elevated IOP had less thickening of the RNFL in comparison to the eyes with normal IOP. Central macular thickness and macular volume were decreased in the silicone oil filled eyes in comparison to the control eyes. In conclusion, silicone oil caused peripapilar RNFL thickening in the vitrectomized eyes during endotamponade and after silicone oil removal.
Park, Kyung-Ah; Kim, Yoon-Duck; Woo, Kyung In
2018-06-01
The purpose of our study was to assess changes in peripapillary retinal nerve fiber layer (RNFL) thickness after orbital wall decompression in eyes with dysthyroid optic neuropathy (DON). We analyzed peripapillary optical coherence tomography (OCT) images (Cirrus HD-OCT) from controls and patients with DON before and 1 and 6 months after orbital wall decompression. There was no significant difference in mean preoperative peripapillary retinal nerve fiber layer thickness between eyes with DON and controls. The superior and inferior peripapillary RNFL thickness decreased significantly 1 month after decompression surgery compared to preoperative values (p = 0.043 and p = 0.022, respectively). The global average, superior, temporal, and inferior peripapillary RNFL thickness decreased significantly 6 months after decompression surgery compared to preoperative values (p = 0.015, p = 0.028, p = 0.009, and p = 0.006, respectively). Patients with greater preoperative inferior peripapillary RNFL thickness tended to have better postoperative visual acuity at the last visit (p = 0.024, OR = 0.926). Our data revealed a significant decrease in peripapillary RNFL thickness postoperatively after orbital decompression surgery in patients with DON. We also found that greater preoperative inferior peripapillary RNFL thickness was associated with better visual outcomes. We suggest that RNFL thickness can be used as a prognostic factor for DON before decompression surgery.
Liu, Lin; Zou, Jun; Huang, Hui; Yang, Jian-guo; Chen, Shao-rong
2012-05-23
To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was -1.17 diopters (D; SD 0.64; range -0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was -0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of -1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895.
Knight, O'Rese J; Girkin, Christopher A; Budenz, Donald L; Durbin, Mary K; Feuer, William J
2012-03-01
To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P ≤ .005) except rim area (P = .22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r(2) = 0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups.
Knight, O’Rese J.; Girkin, Christopher A.; Budenz, Donald L.; Durbin, Mary K.; Feuer, William J.
2017-01-01
Objective To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. Methods In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. Results The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P≤.005) except rim area (P=.22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r2=0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. Conclusions There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups. PMID:22411660
Savini, G; Zanini, M; Carelli, V; Sadun, A A; Ross-Cisneros, F N; Barboni, P
2005-04-01
To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4 acquisition protocol). ONH analysis was performed by means of six radial scans centred on the optic disc (Stratus OCT, Fast Optic Disc acquisition protocol). The mean RNFL values were correlated with the data obtained by ONH analysis. The superior, nasal, and inferior quadrant RNFL thickness showed a significant correlation with the optic disc area (R = 0.3822, p = 0.0043), (R = 0.3024, p = 0.026), (R = 0.4048, p = 0.0024) and the horizontal disc diameter (R = 0.2971, p = 0.0291), (R = 0.2752, p = 0.044), (R = 0.3970, p = 0.003). The superior and inferior quadrant RNFL thickness was also positively correlated with the vertical disc diameter (R = 0.3774, p = 0.0049), (R = 0.2793, p = 0.0408). A significant correlation was observed between the 360 degrees average RNFL thickness and the optic disc area and the vertical and horizontal disc diameters of the ONH (R = 0.4985, p = 0.0001), (R = 0.4454, p = 0.0007), (R = 0.4301, p = 0.0012). RNFL thickness measurements obtained by Stratus OCT increased significantly with an increase in optic disc size. It is not clear if eyes with large ONHs show a thicker RNFL as a result of an increased amount of nerve fibres or to the shorter distance between the circular scan and the optic disc edge.
Kwon, Jin Young; Yang, Ji Ho; Han, Ji Sang; Kim, Do Gyun
2017-12-01
To compare the retinal nerve fiber layer (RNFL) as well as the macula volume and thickness in the eyes of age-matched healthy controls with no cognitive disabilities with those of elderly people with mild cognitive impairment (MCI) or Alzheimer disease (AD). We used optical coherence tomography (OCT) to determine the effectiveness of the above quantities for early diagnosis of MCI or AD. Ninety eyes were considered in this study, split between 30 normal eyes, 30 eyes from patients with MCI, and 30eyes from patients with AD. All subjects underwent ophthalmologic and cognitive examinations, and measurements of the RNFL thickness as well as macular volume and thickness were taken for all patients using OCT. The mean RNFL thickness upon OCT was significantly thinner in the AD group than in the MCI group (p = 0.01). The RNFL was thinner in the superior quadrant in patients with AD when compared to the healthy controls (p = 0.03). The RNFL thicknesses in the inferior, nasal, and temporal quadrants did not differ significantly between the groups. Measurements in the 12 clock-hour zones revealed that zone 11 had a significantly thinner RNFL in the AD group as compared with the healthy control group (p = 0.02). In zone 2, the MCI group had a significantly thinner RNFL than the AD group (p = 0.03). Our OCT findings revealed a neuroanatomic difference in the RNFL thickness among the three groups, i.e., the AD, MCI, and healthy control groups. This suggests that a change in average RNFL thickness could be a meaningful index for diagnosing early AD. © 2017 The Korean Ophthalmological Society
Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira
2004-12-01
To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.
Mugdha, Kumari; Kaur, Apjit; Sinha, Neha; Saxena, Sandeep
2016-01-01
AIM To evaluate retinal nerve fiber layer (RNFL) thickness profile in patients of thyroid ophthalmopathy with no clinical signs of optic nerve dysfunction. METHODS A prospective, case-control, observational study conducted at a tertiary care centre. Inclusion criteria consisted of patients with eyelid retraction in association with any one of: biochemical thyroid dysfunction, exophthalmos, or extraocular muscle involvement; or thyroid dysfunction in association with either exophthalmos or extra-ocular muscle involvement; or a clinical activity score (CAS)>3/7. Two measurements of RNFL thickness were done for each eye, by Cirrus HD-optical coherence tomography 6mo apart. RESULTS Mean age of the sample was 38.75y (range 13-70y) with 18 males and 22 females. Average RNFL thickness at first visit was 92.06±12.44 µm, significantly lower than control group (101.28±6.64 µm) (P=0.0001). Thickness of inferior quadrant decreased from 118.2±21.27 µm to 115.0±22.27 µm after 6mo (P=0.02). There was no correlation between the change in CAS and RNFL thickness. CONCLUSION Decreased RNFL thickness is an important feature of thyroid orbitopathy, which is an inherent outcome of compressive optic neuropathy of any etiology. Subclinical RNFL damage continues in the absence of clinical activity of the disease. RNFL evaluation is essential in Grave's disease and active intervention may be warranted in the presence of significant damage. PMID:27990368
Toprak, Ibrahim; Yaylalı, Volkan; Yildirim, Cem
2017-01-01
To assess diagnostic consistency and relation between spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in patients with primary open-angle glaucoma (POAG). This retrospective study comprised 51 eyes of 51 patients with a confirmed diagnosis of POAG. The qualitative and quantitative SD-OCT parameters (retinal nerve fiber layer thicknesses [RNFL; average, superior, inferior, nasal and temporal], RNFL symmetry, rim area, disc area, average and vertical cup/disc [C/D] ratio and cup volume) were compared with parameters of SAP (mean deviation, pattern standard deviation, visual field index, and glaucoma hemifield test reports). Fifty-one eyes of 51 patients with POAG were recruited. Twenty-nine eyes (56.9%) had consistent RNFL and visual field (VF) damage. However, nine patients (17.6%) showed isolated RNFL damage on SD-OCT and 13 patients (25.5%) had abnormal VF test with normal RNFL. In patients with VF defect, age, average C/D ratio, vertical C/D ratio, and cup volume were significantly higher and rim area was lower when compared to those of the patients with normal VF. In addition to these parameters, worsening in average, superior, inferior, and temporal RNFL thicknesses and RNFL symmetry was significantly associated with consistent SD-OCT and SAP outcomes. In routine practice, patients with POAG can be manifested with inconsistent reports between SD-OCT and SAP. An older age, higher C/D ratio, larger cup volume, and lower rim area on SD-OCT appears to be associated with detectable VF damage. Moreover, additional worsening in RNFL parameters might reinforce diagnostic consistency between SD-OCT and SAP.
2012-01-01
Background To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Methods Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was −1.17 diopters (D; SD 0.64; range −0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was −0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of −1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. Results No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). Conclusions The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895 PMID:22621341
Hong, Seung Woo; Lee, Seung Bum; Jee, Dong-Hyun; Ahn, Myung Douk
2016-09-01
The purpose of study was to measure the diagnostic utility of interocular retinal nerve fiber layer (RNFL) symmetry and interocular RNFL thickness comparison. Both eyes of 103 normal subjects and 106 glaucoma patients (31 patients with early glaucoma and 75 patients with moderate to severe glaucoma) received comprehensive ophthalmologic evaluation including visual field testing and optic disc scanning using optical coherence tomography. RNFL thickness values for 256 measurement points were rearranged according to a new reference line connecting the optic disc center and the foveola. The interocular RNFL thickness symmetry value and absolute and fractional interocular difference in RNFL thickness were calculated and compared between groups. Area under the receiver operating characteristic curves (AUROCs) were calculated and compared. Among the parameters reflecting whole RNFL status, the corrected interocular RNFL thickness symmetry exhibited the largest AUROCs at all glaucoma stages. RNFL thickness and absolute and fractional interocular difference in RNFL thickness exhibited largest AUROC in the inferotemporal area, regardless of glaucoma stage. In the early glaucoma group, absolute and fractional interocular RNFL thickness differences in the temporal and superotemporal areas exhibited equal to or larger AUROCs than RNFL thickness. The AUROCs for RNFL thickness were greater than those for absolute and fractional interocular RNFL thickness differences in the moderate to severe glaucoma group except in the nasal and temporal area. The corrected interocular RNFL thickness symmetry value is an effective diagnostic tool for glaucoma. Interocular comparison of RNFL thickness has good diagnostic performance and gives information about the RNFL beyond just the RNFL thickness itself.
Goh, Jody P; Koh, Victor; Chan, Yiong Huak; Ngo, Cheryl
2017-07-01
To study the distribution of macular ganglion cell-inner plexiform layer (GC-IPL) thickness and peripapillary retinal nerve fiber layer (RNFL) thickness in children with refractive errors. Two hundred forty-three healthy eyes from 139 children with refractive error ranging from -10.00 to +5.00 D were recruited from the National University Hospital Eye Surgery outpatient clinic. After a comprehensive ocular examination, refraction, and axial length (AL) measurement (IOLMaster), macular GC-IPL and RNFL thickness values were obtained with a spectral domain Cirrus high definition optical coherence tomography system (Carl Zeiss Meditec Inc.). Only scans with signal strength of >6/10 were included. Correlation between variables was calculated using the Pearson correlation coefficient. A multivariate analysis using mixed models was done to adjust for confounders. The mean spherical equivalent refraction was -3.20±3.51 D and mean AL was 24.39±1.72 mm. Average, minimum, superior, and inferior GC-IPL were 82.59±6.29, 77.17±9.65, 83.68±6.96, and 81.64±6.70 μm, respectively. Average, superior, and inferior peripapillary RNFL were 99.00±11.45, 123.20±25.81, and 124.24±22.23 μm, respectively. Average, superior, and inferior GC-IPL were correlated with AL (β=-2.056, P-value 0.000; β=-2.383, P-value 0.000; β=-1.721, P-value 0.000), but minimum GC-IPL was not (β=-1.056, P-value 0.115). None of the RNFL parameters were correlated with AL. This study establishes normative macular GC-IPL and RNFL thickness in children with refractive errors. Our results suggest that high definition optical coherence tomography RNFL parameters and minimum GC-IPL are not affected by AL or myopia in children, and therefore warrants further evaluation in pediatric glaucoma patients.
Quantitative RNFL attenuation coefficient measurements by RPE-normalized OCT data
NASA Astrophysics Data System (ADS)
Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.
2012-03-01
We demonstrate significantly different scattering coefficients of the retinal nerve fiber layer (RNFL) between normal and glaucoma subjects. In clinical care, SD-OCT is routinely used to assess the RNFL thickness for glaucoma management. In this way, the full OCT data set is conveniently reduced to an easy to interpret output, matching results from older (non- OCT) instruments. However, OCT provides more data, such as the signal strength itself, which is due to backscattering in the retinal layers. For quantitative analysis, this signal should be normalized to adjust for local differences in the intensity of the beam that reaches the retina. In this paper, we introduce a model that relates the OCT signal to the attenuation coefficient of the tissue. The average RNFL signal (within an A-line) was then normalized based on the observed RPE signal, resulting in normalized RNFL attenuation coefficient maps. These maps showed local defects matching those found in thickness data. The average (normalized) RNFL attenuation coefficient of a fixed band around the optic nerve head was significantly lower in glaucomatous eyes than in normal eyes (3.0mm-1 vs. 4.9mm-1, P<0.01, Mann-Whitney test).
Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK.
Zangwill, Linda M; Abunto, Teresa; Bowd, Christopher; Angeles, Raymund; Schanzlin, David J; Weinreb, Robert N
2005-02-01
To compare retinal nerve fiber layer (RNFL) thickness measurements before and after LASIK. Cohort study. Twenty participants undergoing LASIK and 14 normal controls. Retinal nerve fiber layer thickness was measured before LASIK and approximately 3 months after surgery in one eye each of 20 patients using a scanning laser polarimeter (GDx Nerve Fiber Analyzer) with fixed corneal compensation (FCC), one with variable corneal compensation (GDx VCC), and optical coherence tomography (OCT). Fourteen normal controls also were tested at baseline and approximately 3 months later. Retinal nerve fiber layer thicknesses measured with the GDx FCC, GDx VCC, and OCT. At baseline, mean (95% confidence interval [CI]) RNFL thicknesses for the GDx FCC, GDx VCC, and OCT were 78.1 microm (72.2-83.9), 54.3 microm (52.7-56.0), and 96.8 microm (93.2-100.5), respectively. In both LASIK and control groups, there were no significant changes between baseline and follow-up examinations in GDx VCC and OCT RNFL thickness measurements globally or in the superior and inferior quadrants (mean change, <5 microm for each instrument). In the control group, there also was no significant change in GDx FCC measurements between baseline and follow-up. In LASIK patients, significant reductions were observed in GDx FCC RNFL measurements. Average absolute values of the mean (95% CI) change in thickness were 12.4 microm (7.7-17.2), 15.3 microm (9.6-20.9), and 12.9 microm (7.6-18.1) for GDx FCC RNFL measurements superiorly, inferiorly, and globally, respectively (all Ps < or = 0.001). LASIK does not seem to change RNFL thickness. Reduction in GDx FCC RNFL thickness measurements after LASIK is a measurement artifact and is most likely due to erroneous compensation for corneal birefringence. With scanning laser polarimetry, it is mandatory to compensate individually for change in corneal birefringence after LASIK to ensure accurate RNFL assessment.
A framework for comparing structural and functional measures of glaucomatous damage
Hood, Donald C.; Kardon, Randy H.
2007-01-01
While it is often said that structural damage due to glaucoma precedes functional damage, it is not always clear what this statement means. This review has two purposes: first, to show that a simple linear relationship describes the data relating a particular functional test (standard automated perimetry (SAP)) to a particular structural test (optical coherence tomography (OCT)); and, second, to propose a general framework for relating structural and functional damage, and for evaluating if one precedes the other. The specific functional and structural tests employed are described in Section 2. To compare SAP sensitivity loss to loss of the retinal nerve fiber layer (RNFL) requires a map that relates local field regions to local regions of the optic disc as described in Section 3. When RNFL thickness in the superior and inferior arcuate sectors of the disc are plotted against SAP sensitivity loss (dB units) in the corresponding arcuate regions of the visual field, RNFL thickness becomes asymptotic for sensitivity losses greater than about 10 dB. These data are well described by a simple linear model presented in Section 4. The model assumes that the RNFL thickness measured with OCT has two components. One component is the axons of the retinal ganglion cells and the other, the residual, is everything else (e.g. glial cells, blood vessels). The axon portion is assumed to decrease in a linear fashion with losses in SAP sensitivity (in linear units); the residual portion is assumed to remain constant. Based upon severe SAP losses in anterior ischemic optic neuropathy (AION), the residual RNFL thickness in the arcuate regions is, on average, about one-third of the premorbid (normal) thickness of that region. The model also predicts that, to a first approximation, SAP sensitivity in control subjects does not depend upon RNFL thickness. The data (Section 6) are, in general, consistent with this prediction showing a very weak correlation between RNFL thickness and SAP sensitivity. In Section 7, the model is used to estimate the proportion of patients showing statistical abnormalities (worse than the 5th percentile) on the OCT RNFL test before they show abnormalities on the 24-2 SAP field test. Ignoring measurement error, the patients with a relatively thick RNFL, when healthy, will be more likely to show significant SAP sensitivity loss before statistically significant OCT RNFL loss, while the reverse will be true for those who start with an average or a relatively thin RNFL when healthy. Thus, it is important to understand the implications of the wide variation in RNFL thickness among control subjects. Section 8 describes two of the factors contributing to this variation, variations in the position of blood vessels and variations in the mapping of field regions to disc sectors. Finally, in Sections 7 and 9, the findings are related to the general debate in the literature about the relationship between structural and functional glaucomatous damage and a framework is proposed for understanding what is meant by the question, ‘Does structural damage precede functional damage in glaucoma?’ An emphasis is placed upon the need to distinguish between “statistical” and “relational” meanings of this question. PMID:17889587
Retinal nerve fibre layer thinning is associated with drug resistance in epilepsy
Balestrini, Simona; Clayton, Lisa M S; Bartmann, Ana P; Chinthapalli, Krishna; Novy, Jan; Coppola, Antonietta; Wandschneider, Britta; Stern, William M; Acheson, James; Bell, Gail S; Sander, Josemir W; Sisodiya, Sanjay M
2016-01-01
Objective Retinal nerve fibre layer (RNFL) thickness is related to the axonal anterior visual pathway and is considered a marker of overall white matter ‘integrity’. We hypothesised that RNFL changes would occur in people with epilepsy, independently of vigabatrin exposure, and be related to clinical characteristics of epilepsy. Methods Three hundred people with epilepsy attending specialist clinics and 90 healthy controls were included in this cross-sectional cohort study. RNFL imaging was performed using spectral-domain optical coherence tomography (OCT). Drug resistance was defined as failure of adequate trials of two antiepileptic drugs to achieve sustained seizure freedom. Results The average RNFL thickness and the thickness of each of the 90° quadrants were significantly thinner in people with epilepsy than healthy controls (p<0.001, t test). In a multivariate logistic regression model, drug resistance was the only significant predictor of abnormal RNFL thinning (OR=2.09, 95% CI 1.09 to 4.01, p=0.03). Duration of epilepsy (coefficient −0.16, p=0.004) and presence of intellectual disability (coefficient −4.0, p=0.044) also showed a significant relationship with RNFL thinning in a multivariate linear regression model. Conclusions Our results suggest that people with epilepsy with no previous exposure to vigabatrin have a significantly thinner RNFL than healthy participants. Drug resistance emerged as a significant independent predictor of RNFL borderline attenuation or abnormal thinning in a logistic regression model. As this is easily assessed by OCT, RNFL thickness might be used to better understand the mechanisms underlying drug resistance, and possibly severity. Longitudinal studies are needed to confirm our findings. PMID:25886782
Huang, Jehn-Yu; Pekmezci, Melike; Mesiwala, Nisreen; Kao, Andrew; Lin, Shan
2011-02-01
To evaluate the capability of the optic disc, peripapillary retinal nerve fiber layer (P-RNFL), macular inner retinal layer (M-IRL) parameters, and their combination obtained by Fourier-domain optical coherent tomography (OCT) in differentiating a glaucoma suspect from perimetric glaucoma. Two hundred and twenty eyes from 220 patients were enrolled in this study. The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis on the basis of OCT parameters and demographic factors. The diagnostic power of these parameters was evaluated with receiver operating characteristic (ROC) curve analysis. The diagnostic power in the clinically relevant range (specificity ≥ 80%) was presented as the partial area under the ROC curve (partial AROC). The individual OCT parameter with the largest AROC and partial AROC in the high specificity (≥ 80%) range were cup/disc vertical ratio (AROC = 0.854 and partial AROC = 0.142) for the optic disc parameters, average thickness (AROC = 0.919 and partial AROC = 0.147) for P-RNFL parameters, inferior hemisphere thickness (AROC = 0.871 and partial AROC = 0.138) for M-IRL parameters, respectively. The linear discriminant function further enhanced the ability in detecting perimetric glaucoma (AROC = 0.970 and partial AROC = 0.172). Average P-RNFL thickness is the optimal individual OCT parameter to detect perimetric glaucoma. Simultaneous evaluation on disc morphology, P-RNFL, and M-IRL thickness can improve the diagnostic accuracy in diagnosing glaucoma.
Yu, Ji-Guo; Huang, Qing; Zhou, Xiao-Fang; Ding, Yi; Li, Jing; Xiang, Yi
2018-01-01
To evaluate and compare changes in retinal nerve fiber layer (RNFL) thickness in patients with the pseudoexfoliation syndrome (PXS) and healthy controls. Case-control studies were selected through an electronic search of the Cochrane Controlled Trials Register, PubMed, and Embase. Results were reviewed to ensure that the included studies met prespecified inclusion/exclusion criteria, and the quality of each study was assessed using the Newcastle-Ottawa Scale. All included studies measured average and 4-quadrant (temporal, superior, nasal, and inferior) RNFL thickness using optical coherence tomography (OCT). For the continuous outcomes, we calculated the weighted mean difference (WMD) and 95% confidence intervals (CIs). Eight case-control studies were included in this meta-analysis involving 225 eyes of PXS patients and 208 eyes of healthy controls in total. Statistical analysis revealed that the average RNFL thickness in PXS patients was significantly reduced compared to healthy controls (WMD = -6.91, 95% CI: -9.99 to -3.82, p < 0.0001). Additionally, differences in RNFL thickness in the superior quadrant (WMD = -10.68, 95% CI: -16.40 to -4.95, p = 0.0003), inferior quadrant (WMD = -8.20, 95% CI: -10.85 to -5.55, p < 0.00001), nasal quadrant (WMD = -3.05, 95% CI: -5.21 to -0.90, p = 0.005), and temporal quadrant (WMD = -6.39, 95% CI: -9.98 to -2.80, p = 0.0005) were all significant between the two groups. These results suggest that it is important to evaluate RNFL thickness and the optic nerve head through OCT in patients with PXS in order to determine early glaucomatous damage and start timely intervention prior to visual field loss. © 2017 S. Karger AG, Basel.
Arifoglu, Hasan Basri; Simavli, Huseyin; Midillioglu, Inci; Berk Ergun, Sule; Simsek, Saban
2017-01-01
To evaluate the ganglion cell complex (GCC) and retinal nerve fiber layer (RNFL) thickness in pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG) with RTVue spectral domain optical coherence tomography (SD-OCT). A total of 102 subjects were enrolled: 29 with PDS, 18 with PG, and 55 normal subjects. Full ophthalmic examination including visual field analysis was performed. SD-OCT was used to analyze GCC superior, GCC inferior, and average RNFL thickness. To compare the discrimination capabilities, the areas under the receiver operating characteristic curves were assessed. Superior GCC, inferior GCC, and RNFL thickness values of patients with PG were statistically signicantly lower than those of patients with PDS (p < 0.001) and healthy individuals (p < 0.001 for all). No statistically significant difference was found between PDS and normal subjects in same parameters (p > 0.05). The SD-OCT-derived GCC and RNFL thickness parameters can be useful to discriminate PG from both PDS and normal subjects.
Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2016-01-01
To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size.
Hložánek, Martin; Ošmera, Jakub; Ležatková, Pavlína; Sedláčková, Petra; Filouš, Aleš
2012-12-01
To compare the thickness of the retinal nerve fibre layer (RNFL) in hydrophthalmic glaucomatous eyes in children with age-matched healthy controls using scanning laser polarimetry with variable corneal compensation (GDxVCC). Twenty hydrophthalmic eyes of 20 patients with the mean age of 10.64 ± 3.02 years being treated for congenital or infantile glaucoma were included in the analysis. Evaluation of RNFL thickness measured by GDxVCC in standard Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was performed. The results were compared to TSNIT values of an age-matched control group of 120 healthy children published recently as referential values. The correlation between horizontal corneal diameter and RNFL thickness in hydrophthalmic eyes was also investigated. The mean ± SD values in TSNIT Average, Superior Average, Inferior Average and TSNIT SD in hydrophthalmic eyes were 52.3 ± 11.4, 59.7 ± 17.1, 62.0 ± 15.6 and 20.0 ± 7.8 μm, respectively. All these values were significantly lower compared to referential TSNIT parameters of age-matched healthy eyes (p = 0.021, p = 0.001, p = 0.003 and p = 0.018, respectively). A substantial number of hydrophthalmic eyes laid below the level of 5% probability of normality in respective TSNIT parameters: 30% of the eyes in TSNIT average, 50% of the eyes in superior average, 30% of the eyes in inferior average and 45% of the eyes in TSNIT SD. No significant correlation between enlarged corneal diameter and RNFL thickness was found. The mean values of all standard TSNIT parameters assessed using GDxVCC in hydrophthalmic glaucomatous eyes in children were significantly lower in comparison with referential values of healthy age-matched children. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Tunç, Abdulkadir; Güngen, Belma Doğan; Evliyaoğlu, Ferhat; Aras, Yeşim Güzey; Tekeşin, Aysel Kaya
2017-03-01
The aim of this study was to investigate retinal nerve fiber layer (RNFL), ganglion cell layer (GCL) thickness, macular changes (central subfield thickness (CST), cube average thickness (CAT), cube volume (CV) in patients with migraine using spectral-domain optical coherence tomography (OCT) and to assess if there was any correlation with white matter lesions (WML). In this prospective case-control study, RNFL, GCL thickness and macular changes of 19 migraine patients with aura (MA), 41 migraine without aura (MO) and 60 age- and gender-matched healthy subjects were measured using OCT device. OCT measurements were taken at the same time of the day to minimize the effects of diurnal variation. The average, inferior and superior quadrant RNFL thickness were significantly thinner in patients with migraine (p = 0.017, p = 0.010, p = 0.048). There was also a significant difference between patients with and without aura in the mean and superior quadrant RNFL thickness (p = 0.02, p = 0.043).While there was a significant thinning in CST and CAT in patients with migraine (p = 0.020), there were no significant difference in GCL measurements (p = 0.184). When the groups were compared to the control group, there were significant differences between MA and the control group regarding average, superior and inferior quadrant RNLF thickness (p < 0.001, p = 0.025, p < 0.001). On the other hand, there were significant differences between MO and the control group regarding average and inferior faces (p = 0.037, p = 0.04). When OCT measurements were evaluated according to the frequency of attacks, CST and GCL thickness were significantly thinner in patients who had more than four attacks a month (p = 0.024, p = 0.014). In patients with WML, only CV measurements were significantly thinner than migraine patients without WML (p = 0.014). The decreased RNFL, CST, CAT and CV of the migraine patients might be related to the vascular pathology of the disease. Because WML was not correlated with the same measurements except CV, we think that further studies are needed to evaluate the etiopathologic relationship between OCT measurements and WML in migraine patients.
Aptel, Florent; Sayous, Romain; Fortoul, Vincent; Beccat, Sylvain; Denis, Philippe
2010-12-01
To evaluate and compare the regional relationships between visual field sensitivity and retinal nerve fiber layer (RNFL) thickness as measured by spectral-domain optical coherence tomography (OCT) and scanning laser polarimetry. Prospective cross-sectional study. One hundred and twenty eyes of 120 patients (40 with healthy eyes, 40 with suspected glaucoma, and 40 with glaucoma) were tested on Cirrus-OCT, GDx VCC, and standard automated perimetry. Raw data on RNFL thickness were extracted for 256 peripapillary sectors of 1.40625 degrees each for the OCT measurement ellipse and 64 peripapillary sectors of 5.625 degrees each for the GDx VCC measurement ellipse. Correlations between peripapillary RNFL thickness in 6 sectors and visual field sensitivity in the 6 corresponding areas were evaluated using linear and logarithmic regression analysis. Receiver operating curve areas were calculated for each instrument. With spectral-domain OCT, the correlations (r(2)) between RNFL thickness and visual field sensitivity ranged from 0.082 (nasal RNFL and corresponding visual field area, linear regression) to 0.726 (supratemporal RNFL and corresponding visual field area, logarithmic regression). By comparison, with GDx-VCC, the correlations ranged from 0.062 (temporal RNFL and corresponding visual field area, linear regression) to 0.362 (supratemporal RNFL and corresponding visual field area, logarithmic regression). In pairwise comparisons, these structure-function correlations were generally stronger with spectral-domain OCT than with GDx VCC and with logarithmic regression than with linear regression. The largest areas under the receiver operating curve were seen for OCT superior thickness (0.963 ± 0.022; P < .001) in eyes with glaucoma and for OCT average thickness (0.888 ± 0.072; P < .001) in eyes with suspected glaucoma. The structure-function relationship was significantly stronger with spectral-domain OCT than with scanning laser polarimetry, and was better expressed logarithmically than linearly. Measurements with these 2 instruments should not be considered to be interchangeable. Copyright © 2010 Elsevier Inc. All rights reserved.
Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis
NASA Astrophysics Data System (ADS)
Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.
2013-03-01
Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.
Şahin, Muhammed; Şahin, Alparslan; Kılınç, Faruk; Yüksel, Harun; Özkurt, Zeynep Gürsel; Türkcü, Fatih Mehmet; Pekkolay, Zafer; Soylu, Hikmet; Çaça, İhsan
2017-06-01
Increased secretion of growth hormone and insulin-like growth factor-1 in acromegaly has various effects on multiple organs. However, the ocular effects of acromegaly have yet to be investigated in detail. The aim of the present study was to compare retina ganglion cell/inner plexiform layer (GCIPL) and peripapillary nerve fiber layer thickness (pRNFL) between patients with acromegaly and healthy control subjects using spectral domain optical coherence tomography (SD-OCT). This cross-sectional, comparative study included 18 patients with acromegaly and 20 control subjects. All participants underwent SD-OCT to measure pRNFL (in the seven peripapillary areas), GCIPL (in the nine ETDRS areas), and central macular thickness (CMT). Visual field (VF) examinations were performed using a Humphrey field analyzer in acromegalic patients. Measurements were compared between patients with acromegaly and control subjects. A total of 33 eyes of 18 patients with acromegaly and 40 eyes of 20 control subjects met the inclusion criteria of the present study. The overall calculated average pRNFL thickness was significantly lower in patients with acromegaly than in control subjects (P = 0.01), with pRNFL thickness significantly lower in the temporal superior and temporal inferior quadrants. Contrary to our expectations, pRNFL thickness in the nasal quadrant was similar between acromegalic and control subjects. The mean overall pRNFL thickness and superonasal, nasal, inferonasal, and inferotemporal quadrant pRNFL thicknesses were found to correlate with the mean deviation (MD) according to Spearman's correlation. However, other quadrants were not correlated with VF sensitivity. No significant difference in CMT values was observed (P = 0.6). GCIPL thickness was significantly lower in all quadrants of the inner and outer macula, except for central and inferior outer quadrants, in the acromegaly group than that in the control group (P < 0.05). GCIPL thicknesses of the inferior inner and outer macula quadrants were found to correlate with MD, whereas no correlation was observed between other quadrants and VF sensitivity. We demonstrated that GCIPL thickness decreased in patients with acromegaly compared with that in control subjects. However, the nasal quadrant pRNFL thickness was similar in acromegaly, in contrast to our expectations. SD-OCT may have utility in the assessment of the effects of acromegaly on retinal structures.
Barboni, Piero; Carbonelli, Michele; Savini, Giacomo; Ramos, Carolina do V F; Carta, Arturo; Berezovsky, Adriana; Salomao, Solange R; Carelli, Valerio; Sadun, Alfredo A
2010-03-01
To investigate by optical coherence tomography (OCT) the topographic pattern and temporal sequence of fiber loss in the peripapillary retinal nerve fiber layer (RNFL) of patients with Leber's hereditary optic neuropathy (LHON) in a longitudinal follow-up. Cohort study. Six eyes of 4 patients with molecularly defined LHON were enrolled before the subacute period of visual loss. Subjects were studied by StratusOCT (Carl Zeiss Meditec, Inc., Dublin, CA) during a 9-month follow-up starting from the presymptomatic stage of the disease. Examinations were carried out at 4 different time points: presymptomatic stage, time of visual loss, and 3 and 9 months later. Peripapillary RNFL thickness for each quadrant of the optic nerve. Statistical comparisons were performed by ordinary analysis of variance with Dunnett's post-test. A significant increase of RNFL thickness was detected in the temporal and inferior quadrants between the presymptomatic stage and the disease onset (P<0.05). The 360-degree average and the superior and nasal quadrants showed a nonstatistically significant increase of thickness at this time. In the 360-degree average (P<0.01), superior (P<0.01), nasal (P<0.05), and inferior (P<0.01) quadrants, RNFL thickening showed statistically significant changes between the presymptomatic stage and the 3-month follow-up. At 3 months, a nonsignificant reduction of RNFL thickness was detected in the temporal quadrant. A significant reduction of RNFL was detected in all but the nasal quadrants between the presymptomatic stage and the 9-month Follow-up. The RNFL thickness increase first appeared at the temporal and inferior quadrants. Conversely, at 3 months the thickening fibers were more evident in the superior and nasal quadrants. These findings are consistent with the established preferential early involvement of the papillomacular bundle in LHON. We also demonstrated the previously unrecognized simultaneous early involvement of the inferior quadrant. The late involvement of both superior and nasal quadrants suggests a dynamic evolution of the acute stage that continues for 3 months and may represent a therapeutic window of opportunity. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Bellocq, David; Maucort-Boulch, Delphine; Kodjikian, Laurent; Denis, Philippe
2017-03-01
To evaluate the correlation of retinal nerve fibre layer (RNFL) thickness measured using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP) in uveitic eyes compared with healthy eyes. A descriptive, observational, prospective, consecutive, cross-sectional, controlled, monocentre case series was conducted from May to October 2015. Clinical characteristics, best-corrected visual acuity, intraocular pressure, RNFL thickness measurement with SD-OCT and SLP using GDx variable corneal compensation (GDx VCC) were performed for each patient. An evaluation of anterior chamber inflammation with laser flare-cell meter was also carried out. Correlations between SD-OCT and GDx VCC RNFL measurement were evaluated by linear regression analysis. Fifty-four patients were included and divided into two groups: 50 healthy eyes in 29 patients and 42 uveitic eyes in 25 patients. The mean RNFL thickness was 98.08(±8.42) and 113.21(±20.53) μm in the healthy group and the uveitic group, respectively, when measured with SD-OCT (p<0.001); and 56.43(±5.24) and 58.77(±6.67) μm, respectively, when measured with GDx VCC (p=0.078). There was a strong correlation between total average RNFL thickness measured using SD-OCT and GDX (r=0.48, p<0.001) in healthy eyes but there was no correlation in the uveitic eyes (r=0.2, p=0.19). RNFL thickness was significantly greater when measured using SD-OCT in active uveitis as compared with GDx. There was no correlation between the RNFL thickness measurements obtained using the two techniques in uveitic eyes. The discrepancies between the results suggest that for these patients both techniques should be used in conjunction to obtain an accurate measurement of RNFL. IRB 00008855 Société Française d'Ophtalmologie IRB#1. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
García-Medina, José Javier; García-Piñero, María; Del-Río-Vellosillo, Mónica; Fares-Valdivia, Jesarán; Ragel-Hernández, Ana Belén; Martínez-Saura, Salvador; Cárcel-López, María Dolores; Zanon-Moreno, Vicente; Pinazo-Duran, María Dolores; Villegas-Pérez, María Paz
2017-11-01
To compare thicknesses of intraretinal layers segmented by spectral-domain optical coherence tomography (SD-OCT) between autism spectrum disorder (ASD) and neurotypical (NT) individuals. We performed 2 scans on 108 eyes from 54 participants (27 high-functioning ASD and 27 age- and sex-matched NT subjects): macular fast volume and peripapillary retinal nerve fiber layer (pRNFL). Macula was automatically segmented. The mean foveal and macular thickness of nine different layers and the thickness of nine pRNFL sectors were considered. Data from the right and left eyes were averaged for each participant. The results were compared between the ASD and NT groups. Associations between the Kaufman brief intelligence test (K-BIT), head circumference and SD-OCT results were also investigated in ASD individuals. ASD subjects showed greater foveal thickness at total retina, total inner retina, inner plexiform and inner nuclear layers, and greater macular thickness at total retina and total inner retina. Inferior, nasal inferior and temporal inferior sectors of pRNFL were also thicker in the ASD participants than in the controls (P < 0.05, unpaired t-test). Significant correlations were found between some K-BIT results and temporal inferior and inferior pRNFL thicknesses in the ASD group (P < 0.05, Spearman's rank correlation). No associations were seen between head circumference and OCT parameters. There are intraretinal thickenings at different locations in ASD subjects when compared to NT controls. This fact should be taken into account when interpreting SD-OCT examinations in ASD individuals. Plus, some pRNFL thicknesses present positive correlations with scores of cognitive status in ASD.
Park, Jung-Won; Jung, Hyun-Ho; Heo, Hwan; Park, Sang-Woo
2015-08-01
To evaluate the diagnostic validity of temporal-to-nasal macular ganglion cell-inner plexiform layer thickness (TNM) ratio using Cirrus high definition-optical coherence tomography (HD-OCT) in patients with early glaucomatous damage. Enrolled participants included 130 normal controls, 50 patients with preperimetric glaucoma and 106 patients with early glaucoma. The patients with early glaucoma were classified into two subgroups according to the pattern of the visual field (VF) defects: the paracentral scotoma (PCS, n = 54) and the peripheral scotoma (PPS, n = 52). The thickness of the macular ganglion cell-inner plexiform layer (mGCIPL) and circumpapillary retinal nerve fibre layer (cpRNFL) was measured by Cirrus HD-OCT, and the average, superior and inferior TNM ratio was calculated. The average TNM ratio is a sum of superotemporal and inferotemporal mGCIPL thicknesses divided by the sum of superonasal and inferonasal mGCIPL thicknesses. Area under the receiver operating characteristic curve (AROC) of each parameter was compared between the groups. The parameter with the best AROC was the average TNM ratio and inferotemporal mGCIPL thickness in the PCS group and average cpRNFL thickness in the PPS group. The AROCs of the average, superior and inferior TNM ratio (p < 0.001, p = 0.007 and p < 0.001, respectively), minimum, average, inferotemporal and inferior mGCIPL thickness (p = 0.004, p = 0.003, p = 0.002 and p = 0.001, respectively) of the PCS were significantly higher than those of the PPS. However, the AROCs of the all cpRNFL thickness parameters did not show statistically significant differences between two subgroups. Asymmetry of temporal-to-nasal mGCIPL thickness could be an important parameter in the diagnosis of early glaucoma with paracentral VF defects. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Gao, LiYan; Liu, Ying; Li, XiaoHong; Bai, QuanHao; Liu, Ping
2015-01-01
We investigated possible abnormalities in the retinal nerve fiber layer (RNFL) and macula lutea of patients diagnosed with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and tested for any correlation with the severity of dementia. A total of 72 subjects, comprising 25 AD patients, 26 MCI patients and 21 healthy individuals (controls) were enrolled in this study. The thickness of the RNFL and volume of the macula lutea was determined using optical coherence tomography (OCT). When compared with controls, we found statistically significant thinning of the RNFL in AD patients at all clock-hour positions except 12:00, and nasal quadrant, 2:00, 3:00 and 4:00. After adjusting several risk factors, the average thickness of the RNFL was reduced in MCI patients compared to AD patients, with specific reductions at inferior quadrant, 5:00 and 6:00. Compared to controls, MCI patients showed a significant decrease in RNFL thickness only in the temporal quadrant, 8:00, 9:00 and 10:00. We found significant reduction in the volume of the macula lutea both in AD and MCI patients. Finally, we could not establish any correlation between patient Mini-Mental State Examination (MMSE) scores (an estimation of the severity of cognitive impairment) and any OCT parameter. Retinal degeneration in AD and MCI patients results in decreased thickness of the RNFL, and reduced macular volume in AD and MCI patients. However, there seems to be no correlation between these changes and the severity of dementia. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung
2016-01-01
Purpose To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. Methods A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Results Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Conclusions Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size. PMID:27490718
Bae, Hyoung Won; Lee, Sang Yeop; Kim, Sangah; Park, Chan Keum; Lee, Kwanghyun; Kim, Chan Yun; Seong, Gong Je
2018-01-01
To assess whether the asymmetry in the peripapillary retinal nerve fiber layer (pRNFL) thickness between superior and inferior hemispheres on optical coherence tomography (OCT) is useful for early detection of glaucoma. The patient population consisted of Training set (a total of 60 subjects with early glaucoma and 59 normal subjects) and Validation set (30 subjects with early glaucoma and 30 normal subjects). Two kinds of ratios were employed to measure the asymmetry between the superior and inferior pRNFL thickness using OCT. One was the ratio of the superior to inferior peak thicknesses (peak pRNFL thickness ratio; PTR), and the other was the ratio of the superior to inferior average thickness (average pRNFL thickness ratio; ATR). The diagnostic abilities of the PTR and ATR were compared to the color code classification in OCT. Using the optimal cut-off values of the PTR and ATR obtained from the Training set, the two ratios were independently validated for diagnostic capability. For the Training set, the sensitivities/specificities of the PTR, ATR, quadrants color code classification, and clock-hour color code classification were 81.7%/93.2%, 71.7%/74.6%, 75.0%/93.2%, and 75.0%/79.7%, respectively. The PTR showed a better diagnostic performance for early glaucoma detection than the ATR and the clock-hour color code classification in terms of areas under the receiver operating characteristic curves (AUCs) (0.898, 0.765, and 0.773, respectively). For the Validation set, the PTR also showed the best sensitivity and AUC. The PTR is a simple method with considerable diagnostic ability for early glaucoma detection. It can, therefore, be widely used as a new screening method for early glaucoma. © Copyright: Yonsei University College of Medicine 2018
Chien, Jason L; Ghassibi, Mark P; Patthanathamrongkasem, Thipnapa; Abumasmah, Ramiz; Rosman, Michael S; Skaat, Alon; Tello, Celso; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul
2017-03-01
To compare glaucoma diagnostic capability of global/regional macular layer parameters in different-sized grids. Serial horizontal spectral-domain optical coherence tomography scans of macula were obtained. Automated macular grids with diameters of 3, 3.45, and 6 mm were used. For each grid, 10 parameters (total volume; average thicknesses in 9 regions) were obtained for 5 layers: macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), ganglion cell-inner plexiform layer (GCIPL; GCL+IPL), and ganglion cell complex (GCC; mRNFL+GCL+IPL). Sixty-nine normal eyes (69 subjects) and 87 glaucomatous eyes (87 patients) were included. For the total volume parameter, the area under the receiver operating characteristic curves (AUCs) in 6-mm grid were larger than the AUCs in 3- and 3.45-mm grids for GCL, GCC, GCIPL, and mRNFL (all P<0.020). For the average thickness parameters, the best AUC in 6-mm grid (T2 region for GCL, IPL, and GCIPL; I2 region for mRNFL and GCC) was greater than the best AUC in 3-mm grid for GCL, GCC, and mRNFL (P<0.045). The AUC of GCL volume (0.920) was similar to those of GCC (0.920) and GCIPL (0.909) volume. The AUC of GCL T2 region thickness (0.942) was similar to those of GCC I2 region (0.942) and GCIPL T2 region (0.934) thickness. Isolated macular GCL appears to be as good as GCC and GCIPL in glaucoma diagnosis, while IPL does not. Larger macular grids may be better at detecting glaucoma. Each layer has a characteristic region with the best glaucoma diagnostic capability.
Ambiya, Vikas; Goud, Abhilash; Khodani, Mitali; Chhablani, Jay
2017-04-01
The aim of this study was to evaluate ganglion cell layer and nerve fiber layer thickness after Brilliant Blue G (BBG)-assisted internal limiting membrane (ILM) peeling for vitreomacular disorders. Retrospective analysis of spectral domain optical coherence tomography (SD-OCT) of 42 eyes of 42 patients, who underwent pars plana vitrectomy with BBG-assisted ILM peeling, was performed. Inclusion criteria were idiopathic macular hole, idiopathic vitreomacular traction, and idiopathic epiretinal membrane. Key exclusion criteria were vitreoretinal interface abnormalities secondary to any other diseases, follow-up period of less than 3 months, and any other associated retinal pathology. Average, minimum, and sectoral ganglion cell, and inner plexiform layers (GCIPL) and retinal nerve fiber layer (RNFL) parameters were collected. Changes in these parameters from baseline to 3- and 6-month visits after surgery were analyzed. At 3 months after surgery, we found a statistically significant reduction in the average GCIPL thickness (P = 0.031) and also in the superior sectors (P < 0.05) compared to the baseline values. A similar reduction was observed in the minimum RNFL thickness (P = 0.028) as well as in the superior sectoral RNFL thickness (P < 0.05). In 14 eyes with 6 months of follow-up, a similar statistically significant thinning of the GCIPL and RNFL was observed. However, the difference between the 3-month and 6-month values was not statistically significant (P = 0.679). BBG-assisted ILM peeling for vitreomacular interface disorders leads to thinning of the inner retina including GCIPL and RNFL. These structural changes should be correlated with retinal function tests to explore the pros and cons of this surgical step.
Stemplewitz, Birthe; Keserü, Matthias; Bittersohl, Diana; Buhmann, Carsten; Skevas, Christos; Richard, Gisbert; Hassenstein, Andrea
2015-12-01
Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP). Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed. Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD. PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Alasil, Tarek; Wang, Kaidi; Yu, Fei; Field, Matthew G.; Lee, Hang; Baniasadi, Neda; de Boer, Johannes F.; Coleman, Anne L.; Chen, Teresa C.
2015-01-01
Purpose To determine the retinal nerve fiber layer (RNFL) thickness at which visual field (VF) damage becomes detectable and associated with structural loss. Design Retrospective cross-sectional study. Methods Eighty seven healthy and 108 glaucoma subjects (one eye per subject) were recruited from an academic institution. All patients had VF examinations (Swedish Interactive Threshold Algorithm 24-2 test of the Humphrey visual field analyzer 750i; Carl Zeiss Meditec, Dublin, CA) and spectral domain optical coherence tomography RNFL scans (Spectralis, Heidelberg Engineering, Heidelberg, Germany). Comparison of RNFL thicknesses values with VF threshold values showed a plateau of VF threshold values at high RNFL thickness values and then a sharp decrease at lower RNFL thickness values. A broken stick statistical analysis was utilized to estimate the tipping point at which RNFL thickness values are associated with VF defects. The slope for the association between structure and function was computed for data above and below the tipping point. Results The mean RNFL thickness value that was associated with initial VF loss was 89 μm. The superior RNFL thickness value that was associated with initial corresponding inferior VF loss was 100 μm. The inferior RNFL thickness value that was associated with initial corresponding superior VF loss was 73 μm. The differences between all the slopes above and below the aforementioned tipping points were statistically significant (p<0.001). Conclusions In open angle glaucoma, substantial RNFL thinning or structural loss appears to be necessary before functional visual field defects become detectable. PMID:24487047
Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián
2018-02-01
This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.
Dada, Tanuj; Aggarwal, A; Bali, S J; Sharma, A; Shah, B M; Angmo, D; Panda, A
2013-01-01
Myopia presents a significant challenge to the ophthalmologist as myopic discs are often large, tilted, with deep cups and have a thinner neuroretinal rim all of which may mimic glaucomatous optic nerve head changes causing an error in diagnosis. To evaluate the retinal fiber layer (RNFL) thickness in low, moderate and high myopia using scanning laser polarimetry with variable corneal compensation (GDxVCC). One hundred eyes of 100 emmetropes, 30 eyes of low myopes (0 to - 4 D spherical equivalent(SE), 45 eyes with moderate myopia (- 4 to - 8D SE), and 30 eyes with high myopia (- 8 to - 15D SE) were subjected to retinal nerve fiber layer assessment using the scanning laser polarimetry (GDxVCC) in all subjects using the standard protocol. Subjects with IOP > 21 mm Hg, optic nerve head or visual field changes suggestive of glaucoma were excluded from the study. The major outcome parameters were temporal-superior-nasal-inferiortemporal (TSNIT) average, the superior and inferior average and the nerve fibre indicator (NFI). The TSNIT average (p = 0.009), superior (p = 0.001) and inferior average (p = 0.008) were significantly lower; the NFI was higher (P less than 0.001) in moderate myopes as compared to that in emmetropes. In high myopia the RNFL showed supranormal values; the TSNIT average, superior and inferior average was significantly higher(p less than 0.001) as compared to that in emmetropes. The RNFL measurements on scanning laser polarimetry are affected by the myopic refractive error. Moderate myopes show a significant thinning of the RNFL. In high myopia due to peripapillary chorioretinal atrophy and contribution of scleral birefringence, the RNFL values are abnormally high. These findings need to be taken into account while assessing and monitoring glaucoma damage in moderate to high myopes on GDxVCC. © NEPjOPH.
Mwanza, Jean-Claude; Budenz, Donald L; Godfrey, David G; Neelakantan, Arvind; Sayyad, Fouad E; Chang, Robert T; Lee, Richard K
2014-04-01
To evaluate the glaucoma diagnostic performance of ganglion cell inner-plexiform layer (GCIPL) parameters used individually and in combination with retinal nerve fiber layer (RNFL) or optic nerve head (ONH) parameters measured with Cirrus HD-OCT (Carl Zeiss Meditec, Inc, Dublin, CA). Prospective cross-sectional study. Fifty patients with early perimetric glaucoma and 49 age-matched healthy subjects. Three peripapillary RNFL and 3 macular GCIPL scans were obtained in 1 eye of each participant. A patient was considered glaucomatous if at least 2 of the 3 RNFL or GCIPL scans had the average or at least 1 sector measurement flagged at 1% to 5% or less than 1%. The diagnostic performance was determined for each GCIPL, RNFL, and ONH parameter as well as for binary or-logic and and-logic combinations of GCIPL with RNFL or ONH parameters. Sensitivity, specificity, positive likelihood ratio (PLR), and negative likelihood ratio (NLR). Among GCIPL parameters, the minimum had the best diagnostic performance (sensitivity, 82.0%; specificity, 87.8%; PLR, 6.69; and NLR, 0.21). Inferior quadrant was the best RNFL parameter (sensitivity, 74%; specificity, 95.9%; PLR, 18.13; and NLR, 0.27), as was rim area (sensitivity, 68%; specificity, 98%; PLR, 33.3; and NLR, 0.33) among ONH parameters. The or-logic combination of minimum GCIPL and average RNFL provided the overall best diagnostic performance (sensitivity, 94%; specificity, 85.7%; PRL, 6.58; and NLR, 0.07) as compared with the best RNFL, best ONH, and best and-logic combination (minimum GCIPL and inferior quadrant RNFL; sensitivity, 64%; specificity, 100%; PLR, infinity; and NPR, 0.36). The binary or-logic combination of minimum GCIPL and average RNFL or rim area provides better diagnostic performances than those of and-logic combinations or best single GCIPL, RNFL, or ONH parameters. This finding may be clinically valuable for the diagnosis of early glaucoma. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Yang, Zhiyong; Tatham, Andrew J; Weinreb, Robert N; Medeiros, Felipe A; Liu, Ting; Zangwill, Linda M
2015-01-01
To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements. The study included 106 glaucomatous eyes of 80 subjects and 41 eyes of 22 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Macular ganglion cell and inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and cpRNFL thickness were assessed using SS-OCT and SD-OCT, and area under the receiver operating characteristic curves (AUCs) were calculated to determine ability to differentiate glaucomatous and healthy eyes and between early glaucomatous and healthy eyes. Mean (± standard deviation) mGCIPL and mGCC thickness were thinner in both healthy and glaucomatous eyes using SS-OCT compared to using SD-OCT. Fixed and proportional biases were detected between SS-OCT and SD-OCT measures. Diagnostic accuracy (AUCs) for differentiating between healthy and glaucomatous eyes for average and sectoral mGCIPL was similar in SS-OCT (0.65 to 0.81) and SD-OCT (0.63 to 0.83). AUCs for average cpRNFL acquired using SS-OCT and SD-OCT tended to be higher (0.83 and 0.85, respectively) than for average mGCC (0.82 and 0.78, respectively), and mGCIPL (0.73 and 0.75, respectively) but these differences did not consistently reach statistical significance. Minimum SD-OCT mGCIPL and mGCC thickness (unavailable in SS-OCT) had the highest AUC (0.86) among macular measurements. Assessment of mGCIPL thickness using SS-OCT or SD-OCT is useful for detecting glaucomatous damage, but measurements are not interchangeable for patient management decisions. Diagnostic accuracies of mGCIPL and mGCC from both SS-OCT and SD-OCT were similar to that of cpRNFL for glaucoma detection.
Yang, Zhiyong; Tatham, Andrew J.; Weinreb, Robert N.; Medeiros, Felipe A.; Liu, Ting; Zangwill, Linda M.
2015-01-01
Purpose To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements. Methods The study included 106 glaucomatous eyes of 80 subjects and 41 eyes of 22 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Macular ganglion cell and inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and cpRNFL thickness were assessed using SS-OCT and SD-OCT, and area under the receiver operating characteristic curves (AUCs) were calculated to determine ability to differentiate glaucomatous and healthy eyes and between early glaucomatous and healthy eyes. Results Mean (± standard deviation) mGCIPL and mGCC thickness were thinner in both healthy and glaucomatous eyes using SS-OCT compared to using SD-OCT. Fixed and proportional biases were detected between SS-OCT and SD-OCT measures. Diagnostic accuracy (AUCs) for differentiating between healthy and glaucomatous eyes for average and sectoral mGCIPL was similar in SS-OCT (0.65 to 0.81) and SD-OCT (0.63 to 0.83). AUCs for average cpRNFL acquired using SS-OCT and SD-OCT tended to be higher (0.83 and 0.85, respectively) than for average mGCC (0.82 and 0.78, respectively), and mGCIPL (0.73 and 0.75, respectively) but these differences did not consistently reach statistical significance. Minimum SD-OCT mGCIPL and mGCC thickness (unavailable in SS-OCT) had the highest AUC (0.86) among macular measurements. Conclusion Assessment of mGCIPL thickness using SS-OCT or SD-OCT is useful for detecting glaucomatous damage, but measurements are not interchangeable for patient management decisions. Diagnostic accuracies of mGCIPL and mGCC from both SS-OCT and SD-OCT were similar to that of cpRNFL for glaucoma detection. PMID:25978420
Chansangpetch, Sunee; Huang, Guofu; Coh, Paul; Oldenburg, Catherine; Amoozgar, Behzad; He, Mingguang; Lin, Shan C
2018-04-01
To compare optic nerve head, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell complex (GCC) parameters between Caucasian and ethnic Chinese. Normal subjects above 40 years old and self-identified as being Caucasian and Chinese were recruited. They were evaluated with spectral-domain optical coherence tomography (RTVue-100). Parameters related to the optic nerve head, pRNFL, and GCC analysis protocols were acquired. Multivariable linear regression was performed adjusting for potential confounders. Data from 116 Caucasian and 130 Chinese subjects were available for analysis. Mean age of all participants was 66.72 (SD 10.82) years. There were statistically significant differences for disc area (DA), area cup-to-disc, vertical cup-to-disc, and cup volume (P=0.02, 0.004, 0.02, and 0.03, respectively), greater in Chinese. After adjusting for age, sex, axial length (AL), intraocular pressure (IOP), DA, and GCC thickness, Chinese subjects had significantly greater thickness in all pRNFL parameters (mean differences ranged between 4.29 and 9.93 μm; all P<0.001) except the nasal quadrant. GCC outcomes were also adjusted for DA and pRNFL; Caucasians had significantly higher average GCC and inferior GCC (mean difference 2.97 and 3.45 μm, respectively; P<0.01), whereas the Chinese group had significantly higher ganglion cell global loss volume (mean difference 2.47 %, P<0.001). This study suggests there is significantly greater pRNFL thickness in Chinese, which were independent of age, AL, IOP, and DA, and possibly greater GCC in Caucasians after adjustment for age, AL, IOP, DA, and pRNFL thickness.
Retinal Nerve Fiber Layer Thickness in Children With ADHD.
Hergüner, Arzu; Alpfidan, İsmail; Yar, Ahmet; Erdoğan, Erkan; Metin, Özge; Sakarya, Yaşar; Hergüner, Sabri
2018-05-01
The current study aims to compare retinal nerve fiber layer (RNFL) thickness, macular thickness, and macular volume between children with ADHD and a control group. The study group included children with ADHD and the control group consisted of age- and gender-matched participants without any psychiatric disorder. In all participants, RNFL thickness, macular thickness, and macular volume were measured by using spectral domain-optical coherence tomography (SD-OCT). ADHD symptom severity was evaluated by using parent-report measures, including Conners' Parent Rating Scale-Revised: Short Form (CPRS-R: S) and the Strengths and Difficulties Questionnaire: Parent Form (SDQ: P). We compared 90 eyes of 45 children with ADHD and 90 eyes of 45 controls. ADHD group had significantly lower RNFL thickness only in nasal quadrant than the controls. The remaining RNFL quadrants, macular thickness, and volume were not significantly different between groups. There was a reverse correlation between RNFL thickness and ADHD symptom severity. This is the first study examining the RNFL thickness in ADHD. Our findings showed that nasal RNFL thickness was lower, indicating reduced unmyelinated axons in the retina of children with ADHD. The results of this study support the evidence that ADHD involves a lag in cortical maturation and this is measurable in the retina.
The Distinct Biometric Features of High Myopia Compared to Moderate Myopia.
Chung, Hye Jin; Park, Chan Kee
2016-12-01
To evaluate changes in biometric parameters in myopic eyes. 412 eyes of 412 young myopic patients underwent ophthalmic examinations including assessments of refractive error, axial length (AL), anterior chamber depth (ACD), and central corneal thickness (CCT). By using spectral domain optical coherence tomography (SD-OCT), peripapillary retinal nerve fiber layer (pRNFL) thickness was measured. Subjects were divided into two groups: a moderate-myope group (-6 diopters (D) or more) and a high-myope group (less than -6 D). The relationships among ocular biometric parameters including pRNFL thickness, AL, ACD, and CCT were calculated for each group. In the moderate-myopia group, the anterior chamber deepened as AL increased (Pearson's coefficient = 0.346, p < 0.01). However, in the high-myopia group, ACD did not correlate with AL (Pearson's r = 0.065, p = 0.383). Average pRNFL thickness was also more related to SE than AL in highly myopic eyes. In highly myopic eyes, ACD did not increase as AL increased. pRNFL thickness was more related to SE than to AL. That might be due to the uneven elongation of anterior and posterior portions of the eyeball and the discrepancy between distance from the cornea to the fovea and distance from the cornea to the bottom of the eyeball as axial eye elongation. Interpretation of ocular biometric parameter in highly myopic eyes should consider these differences.
Nurieva, Olga; Diblik, Pavel; Kuthan, Pavel; Sklenka, Petr; Meliska, Martin; Bydzovsky, Jan; Heissigerova, Jarmila; Urban, Pavel; Kotikova, Katerina; Navratil, Tomas; Komarc, Martin; Seidl, Zdenek; Vaneckova, Manuela; Pelclova, Daniela; Zakharov, Sergey
2018-04-27
To study the dynamics and clinical determinants of chronic retinal nerve fiber layer thickness (RNFL) loss after methanol-induced optic neuropathy. Prospective cohort study. All patients underwent complete ophthalmic evaluation including SD-OCT three times during four years of observation:4.9[±0.6], 25.0[±0.6], and 49.9[±0.5] months after discharge. Eighty-four eyes of 42 survivors of methanol poisoning; mean age (standard deviation) of 45.7[±4.4] years, and 82 eyes of 41 controls; mean age 44.0[±4.2] years. global and temporal RNFL loss. Abnormal RNFL thickness was registered in 13/42(31%) survivors of methanol poisoning and chronic axonal loss in 10/42(24%) patients. Significant decrease of global/temporal RNFL thickness during the observation period was found in the study population compared to the controls (p<0.001). The risk estimate of chronic global RNFL loss for arterial blood pH<7.3 at admission was: 11.65(1.91-71.12;95%CI) after adjusting for age and sex. The patients with chronic axonal degeneration demonstrated progressive visual loss in 7/10 cases. The patients with abnormal RNFL thickness had magnetic resonance signs of brain damage in 10/13 versus 8/29 cases with normal RNFL thickness (p=0.003). Signs of brain hemorrhages were present in 7/13 patients with abnormal RNFL thickness versus 5/29 cases with normal RNFL thickness (p=0.015). Methanol-induced optic neuropathy may lead to chronic retinal axonal loss during the following years. Arterial blood pH on admission is the strongest predictor of chronic RNFL thickness decrease. Chronic retinal neurodegeneration is associated with the progressive loss of visual functions and necrotic brain lesions. Copyright © 2018. Published by Elsevier Inc.
Peripapillary Retinoschisis in Glaucoma Patients
Bayraktar, Serife; Cebeci, Zafer; Kabaalioglu, Melis; Ciloglu, Serife; Kir, Nur; Izgi, Belgin
2016-01-01
Purpose. To investigate peripapillary retinoschisis and its effect on retinal nerve fiber layer (RNFL) thickness measurements by using spectral-domain optical coherence tomography (SD-OCT) in glaucomatous eyes. Methods. Circumpapillary RNFL (cpRNFL) B-scan images of 940 glaucoma patients (Group 1) and 801 glaucoma-suspect patients (Group 2) obtained by SD-OCT were reviewed. The structural and clinical characteristics of the retinoschisis were investigated. The RNFL thickness measurements taken at the time of retinoschisis diagnosis and at the follow-up visits were also compared. Results. Twenty-nine retinoschisis areas were found in 26 of the 940 glaucoma patients (3.1%) in Group 1 and seven areas were found in 801 patients (0.87%) in Group 2. In glaucomatous eyes, the retinoschisis was attached to the optic disc and overlapped with the RNFL defect. At the time of retinoschisis, the RNFL thickness was statistically greater in the inferior temporal quadrant when compared with the follow-up scans (p < 0.001). No macular involvement or retinal detachment was observed. Conclusion. The present study investigated 33 peripapillary retinoschisis patients. Increase in RNFL thickness measurements was observed at the time of retinoschisis. It is important to examine the cpRNFL B-scan images of glaucoma patients so that the RNFL thickness is not overestimated. PMID:27069674
Mansberger, Steven L; Menda, Shivali A; Fortune, Brad A; Gardiner, Stuart K; Demirel, Shaban
2017-02-01
To characterize the error of optical coherence tomography (OCT) measurements of retinal nerve fiber layer (RNFL) thickness when using automated retinal layer segmentation algorithms without manual refinement. Cross-sectional study. This study was set in a glaucoma clinical practice, and the dataset included 3490 scans from 412 eyes of 213 individuals with a diagnosis of glaucoma or glaucoma suspect. We used spectral domain OCT (Spectralis) to measure RNFL thickness in a 6-degree peripapillary circle, and exported the native "automated segmentation only" results. In addition, we exported the results after "manual refinement" to correct errors in the automated segmentation of the anterior (internal limiting membrane) and the posterior boundary of the RNFL. Our outcome measures included differences in RNFL thickness and glaucoma classification (i.e., normal, borderline, or outside normal limits) between scans with automated segmentation only and scans using manual refinement. Automated segmentation only resulted in a thinner global RNFL thickness (1.6 μm thinner, P < .001) when compared to manual refinement. When adjusted by operator, a multivariate model showed increased differences with decreasing RNFL thickness (P < .001), decreasing scan quality (P < .001), and increasing age (P < .03). Manual refinement changed 298 of 3486 (8.5%) of scans to a different global glaucoma classification, wherein 146 of 617 (23.7%) of borderline classifications became normal. Superior and inferior temporal clock hours had the largest differences. Automated segmentation without manual refinement resulted in reduced global RNFL thickness and overestimated the classification of glaucoma. Differences increased in eyes with a thinner RNFL thickness, older age, and decreased scan quality. Operators should inspect and manually refine OCT retinal layer segmentation when assessing RNFL thickness in the management of patients with glaucoma. Copyright © 2016 Elsevier Inc. All rights reserved.
Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahinoglu-Keskek, Nedime; Sahin, Alparslan; Sahin, Muhammed; Yuksel, Harun; Caca, Ihsan
2014-09-01
The aim of this study was to evaluate the retinal nerve fiber layer (RNFL) thickness in vernal keratoconjunctivitis (VKC) patients who were under long-term topical corticosteroid therapy. Thirty-six eyes of 36 VKC patients with clear cornea and normal videokeratography and 40 eyes of 40 age- and gender-matched normal children were included in the study. Clinical and demographic characteristics of the patients were noted and detailed ophthalmological examination was performed. Visual acuity (VA), spherical equivalent (SE), axial length (AL) and RNFL thickness measurements were compared between the groups. To correct ocular magnification effect on RNFL, we used Littmann's formula. All VKC patients had history of topical corticosteroid use and the mean duration of the topical corticosteroid use was 23.8 ± 9.09 months. There was no significant difference between the groups in terms of intraocular pressure (IOP). VKC group had significantly worse VA, greater SE and AL and thinner mean global, superior and inferior RNFL thickness. There were significant negative correlations between the duration of topical corticosteroid use and the mean global, superior and temporal RNFL thickness in VKC group. After correction of magnification effect, VKC group still had thinner mean global, superior and inferior RNFL thickness, and significant difference between the groups in inferior RNFL thickness did not disappear. Significant RNFL thickness difference between the groups suggests a possible effect of long-term corticosteroid use in VKC patients. Because visual field (VF) analysis in pediatric patients is difficult to perform and IOP may be illusive, RNFL thickness measurements in addition to routine examinations in VKC patients may help clinicians in their practice.
An Assessment of Retinal Nerve Fiber Layer Thickness in Non-Diabetic Obese Children and Adolescents
Özen, Bediz; Öztürk, Hakan; Çatlı, Gönül; Dündar, Bumin
2018-01-01
Objective: Obesity affects almost all systems in the body. This includes the retinal nerve fibers which may be damaged due to a chronic inflammatory process. To determine changes in retinal nerve fiber layer (RNFL) thickness in non-diabetic children and adolescents using optical coherence tomography (OCT) and to evaluate the relationship between this change, metabolic risk factors and pubertal stage. Methods: Thirty-eight obese and 40 healthy children and adolescents aged 10-18 years were included in the study. RNFL measurements from the optic disk and all surrounding quadrants were obtained using OCT from both eyes of the individuals in the study groups. Correlations between RNFL thickness and age, auxological measurements, pubertal stage, systolic and diastolic blood pressure, homeostasis model assessment-insulin resistance (HOMA-IR) index and lipid values were investigated. Results: A general decrease was observed in RNFL thickness in obese subjects compared to the controls, the decrease being highest in the inferior quadrant, although these differences were not statistically significant (p>0.05). RNFL thickness was negatively correlated with body mass index (BMI) standard deviation score (SDS) in both groups (control group r=-0.345, p=0.029; obese group r=-0.355, p=0.022). Significant negative correlations were determined between diastolic blood pressure, HOMA-IR, low density lipoprotein cholesterol level and RNFL thickness (r=-0.366, p=0.024; r=-0.394, p=0.016; and r=-0.374, p=0.022, respectively) in the obese group, while there was no association between these parameters and RNFL thickness in the control group. Conclusion: In this cross-sectional study, no statistically significant difference in RNFL thicknesses between the obese and control groups was determined. However, RNFL thickness was found to decrease in both healthy and obese children as BMI-SDS values increased. Further prospective studies may be of benefit to determine whether the decrease in RNFL values might become more pronounced on long-term follow-up. PMID:28739552
Chung, Jae Keun; Hwang, Young Hoon; Wi, Jae Min; Kim, Mijin; Jung, Jong Jin
2017-11-01
To investigate the glaucoma diagnostic abilities of vessel density parameters as determined by optical coherence tomography (OCT) angiography in different stages of glaucoma. A total of 113 healthy eyes and 140 glaucomatous eyes were enrolled. Diagnostic abilities of the OCT vessel density parameters in the optic nerve head (ONH), peripapillary, and macular regions were evaluated by calculating the area under the receiver operation characteristic curves (AUCs). AUCs of the peripapillary vessel density parameters and circumpapillary retinal nerve fiber layer (RNFL) thickness were compared. OCT angiography vessel densities in the ONH, peripapillary, and macular regions in the glaucomatous eyes were significantly lower than those in the healthy eyes (P < 0.05). Among the vessel density parameters, the average peripapillary vessel density showed higher AUC than the ONH and macular region (AUCs: 0.807, 0.566, and 0.651, respectively) for glaucoma detection. The peripapillary vessel density parameters showed similar AUCs with the corresponding sectoral RNFL thickness (P > 0.05). However, in the early stage of glaucoma, the AUCs of the inferotemporal and temporal peripapillary vessel densities were significantly lower than that of the RNFL thickness (P < 0.05). The glaucomatous eyes showed decreased vessel density as determined by OCT angiography. Although the peripapillary vessel density parameters showed similar glaucoma diagnostic ability with circumpapillary RNFL thickness, in the early stage, the vessel density parameters showed limited clinical value.
Rajjoub, Raneem D; Trimboli-Heidler, Carmelina; Packer, Roger J; Avery, Robert A
2015-01-01
To determine the intra- and intervisit reproducibility of circumpapillary retinal nerve fiber layer (RNFL) thickness measures using eye tracking-assisted spectral-domain optical coherence tomography (SD OCT) in children with nonglaucomatous optic neuropathy. Prospective longitudinal study. Circumpapillary RNFL thickness measures were acquired with SD OCT using the eye-tracking feature at 2 separate study visits. Children with normal and abnormal vision (visual acuity ≥ 0.2 logMAR above normal and/or visual field loss) who demonstrated clinical and radiographic stability were enrolled. Intra- and intervisit reproducibility was calculated for the global average and 9 anatomic sectors by calculating the coefficient of variation and intraclass correlation coefficient. Forty-two subjects (median age 8.6 years, range 3.9-18.2 years) met inclusion criteria and contributed 62 study eyes. Both the abnormal and normal vision cohort demonstrated the lowest intravisit coefficient of variation for the global RNFL thickness. Intervisit reproducibility remained good for those with normal and abnormal vision, although small but statistically significant increases in the coefficient of variation were observed for multiple anatomic sectors in both cohorts. The magnitude of visual acuity loss was significantly associated with the global (ß = 0.026, P < .01) and temporal sector coefficient of variation (ß = 0.099, P < .01). SD OCT with eye tracking demonstrates highly reproducible RNFL thickness measures. Subjects with vision loss demonstrate greater intra- and intervisit variability than those with normal vision. Copyright © 2015 Elsevier Inc. All rights reserved.
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Schuman, Joel S
2016-01-01
Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t -test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects.
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Kagemann, Larry; Schuman, Joel S.
2016-01-01
Purpose Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Methods Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. Results All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t-test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. Conclusion The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Translational Relevance Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects. PMID:26835180
Longitudinal analysis of progression in glaucoma using spectral-domain optical coherence tomography.
Wessel, Julia M; Horn, Folkert K; Tornow, Ralf P; Schmid, Matthias; Mardin, Christian Y; Kruse, Friedrich E; Juenemann, Anselm G; Laemmer, Robert
2013-05-01
To compare the longitudinal loss of RNFL thickness measurements by SD-OCT in healthy individuals and glaucoma patients with or without progression concerning optic disc morphology. A total of 62 eyes, comprising 38 glaucomatous eyes with open angle glaucoma and 24 healthy controls, were included in the study (Erlangen Glaucoma Registry, NTC00494923). All patients were investigated annually over a period of 3 years by Spectralis SD-OCT measuring peripapillary RNFL thickness. By masked comparative analysis of photographs, the eyes were classified into nonprogressive and progressive glaucoma cases. Longitudinal loss of RNFL thickness was compared with morphological changes of optic disc morphology. Mixed model analysis of annual OCT scans revealed an estimated annual decrease of the RNFL thickness by 2.12 μm in glaucoma eyes with progression, whereas glaucoma eyes without progression in optic disc morphology lost 1.18 μm per year in RNFL thickness (P = 0.002). The rate of change in healthy eyes was 0.60 μm and thereby also significantly lower than in glaucoma eyes with progression (P < 0.001). The intrasession variability of three successive measurements without head repositioning was 1.5 ± 0.7 μm. The loss of mean RNFL thickness exceeded the intrasession variability in 60% of nonprogressive eyes, and in 85% of progressive eyes after 3 years. LONGITUDINAL MEASUREMENTS OF RNFL THICKNESS USING SD-OCT SHOW A MORE PRONOUNCED REDUCTION OF RNFL THICKNESS IN PATIENTS WITH PROGRESSION COMPARED WITH PATIENTS WITHOUT PROGRESSION IN GLAUCOMATOUS OPTIC DISC CHANGES. (www.clinicaltrials.gov number, NTC00494923.).
Retinal and Optic Nerve Degeneration in Patients with Multiple Sclerosis Followed up for 5 Years.
Garcia-Martin, Elena; Ara, Jose R; Martin, Jesus; Almarcegui, Carmen; Dolz, Isabel; Vilades, Elisa; Gil-Arribas, Laura; Fernandez, Francisco J; Polo, Vicente; Larrosa, Jose M; Pablo, Luis E; Satue, Maria
2017-05-01
To quantify retinal nerve fiber layer (RNFL) changes in patients with multiple sclerosis (MS) and healthy controls with a 5-year follow-up and to analyze correlations between disability progression and RNFL degeneration. Observational and longitudinal study. One hundred patients with relapsing-remitting MS and 50 healthy controls. All participants underwent a complete ophthalmic and electrophysiologic exploration and were re-evaluated annually for 5 years. Visual acuity (Snellen chart), color vision (Ishihara pseudoisochromatic plates), visual field examination, optical coherence tomography (OCT), scanning laser polarimetry (SLP), and visual evoked potentials. Expanded Disability Status Scale (EDSS) scores, disease duration, treatments, prior optic neuritis episodes, and quality of life (QOL; based on the 54-item Multiple Sclerosis Quality of Life Scale score). Optical coherence tomography (OCT) revealed changes in all RNFL thicknesses in both groups. In the MS group, changes were detected in average thickness and in the mean deviation using the GDx-VCC nerve fiber analyzer (Laser Diagnostic Technologies, San Diego, CA) and in the P100 latency of visual evoked potentials; no changes were detected in visual acuity, color vision, or visual fields. Optical coherence tomography showed greater differences in the inferior and temporal RNFL thicknesses in both groups. In MS patients only, OCT revealed a moderate correlation between the increase in EDSS and temporal and superior RNFL thinning. Temporal RNFL thinning based on OCT results was correlated moderately with decreased QOL. Multiple sclerosis patients exhibit a progressive axonal loss in the optic nerve fiber layer. Retinal nerve fiber layer thinning based on OCT results is a useful marker for assessing MS progression and correlates with increased disability and reduced QOL. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Dehghani, Cirous; Srinivasan, Sangeetha; Edwards, Katie; Pritchard, Nicola; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2017-05-01
Reduced retinal nerve fiber layer (RNFL) thickness has been demonstrated in patients with diabetic peripheral neuropathy (DPN) in cross-sectional studies. This prospective study defines longitudinal alterations to the RNFL thickness in individuals with type 1 diabetes without (DPN-ve) and with (DPN+ve) DPN and in relation to risk factors for nerve damage. A cohort of 105 individuals with type 1 diabetes (20% DPN+ve) with predominantly mild or no retinopathy and no previous retinal photocoagulation underwent spectral-domain optical coherence tomography (SD-OCT) at baseline, 2 years, and 4 years. SD-OCT scans were acquired at 3.45-mm diameter around the optic nerve head and the overall RNFL and RNFL in the nasal, superior, temporal, and inferior quadrants were quantified. By including serial quantified RNFL parameters, linear mixed models were applied to assess the change in RNFL thickness over time and to explore the associations with other clinical variables. There was a significant decline in the overall RNFL thickness (-0.7 μm/y, P = 0.02) and RNFL in the superior quadrant (-1.9 μm/y, P < 0.01) in the DPN+ve group compared with DPN-ve group. The overall RNFL thickness and RNFL in the superior and nasal quadrants were inversely associated with age (β = -0.29, -0.41, and -0.29, respectively; P ≤ 0.02). Sex, retinopathy, diabetes duration, hemoglobin A1c, lipid profile, blood pressure, cigarette use, alcohol consumption, and body mass index did not show any significant effects (P > 0.05). Individuals with DPN showed a progressive RNFL thinning overall and in the superior quadrant, which was more pronounced in older individuals. There may be common pathways for retinal and peripheral neurodegeneration that are independent of conventional DPN risk factors.
Lim, Jong Hoon; Park, Jun Sang; Lee, So Yeon; Hong, Young Jae
2016-05-25
To investigate the incidence and risk factors of glaucoma in normal-tension glaucoma (NTG) suspect patients who had been lost-to-follow-up for at least 24 months. Seventy-two eyes of 72 NTG suspect patients who returned to the hospital after at least 24 months of follow-up loss were enrolled in this study between January 2009 and June 2013. The data were collected retrospectively. The incidence of glaucoma was investigated using a comprehensive glaucoma evaluation in lost-to-follow-up NTG suspect patients. The patients were classified into the glaucoma group, who developed glaucoma during the study period, and the glaucoma suspect group, who did not, to analyse the risk factors for glaucoma. The number of patients who developed glaucoma was 7 (9.7 %) out of the 72 NTG suspect patients who had been mean lost-to-follow-up for 44 months. The rate of progression from suspected to glaucoma was 2.6 %/year. In the glaucoma group, the baseline intraocular pressure (IOP) was 18.43 ± 2.44 mmHg, and the average retinal nerve fiber layer (RNFL) thickness was 78.14 ± 7.60 μm; in the glaucoma suspect group, the baseline IOP was 14.95 ± 2.47 mmHg, and the average RNFL thickness was 92.55 ± 7.65 μm. The study results showed that the glaucoma group had higher baseline IOP and a thinner average RNFL (p = 0.003; p < 0.001). The results of the multivariable logistic regression analysis showed that the risk factors for glaucoma were high baseline IOP (OR = 1.63; p = 0.037) and a thin average RNFL (OR = 0.841; p = 0.004). The incidence of glaucoma in the lost-to-follow-up NTG suspect patients was 9.7 % for approximately 44 months, at a rate of 2.6 %/year. The risk factors for glaucoma in these patients were high baseline IOP and a thin average RNFL.
Thickness related textural properties of retinal nerve fiber layer in color fundus images.
Odstrcilik, Jan; Kolar, Radim; Tornow, Ralf-Peter; Jan, Jiri; Budai, Attila; Mayer, Markus; Vodakova, Martina; Laemmer, Robert; Lamos, Martin; Kuna, Zdenek; Gazarek, Jiri; Kubena, Tomas; Cernosek, Pavel; Ronzhina, Marina
2014-09-01
Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Ashtari, Fereshteh; Emami, Parisa; Akbari, Mojtaba
2015-01-01
Multiple Sclerosis (MS) is a neurological disease in which demyelination and axonal loss leads to progressive disability. Cognition impairment is among the most common complication. Studying axonal loss in the retina is a new marker for MS. The main goal of our study is to search for correlations between magnetic resonance imaging (MRI) findings and the retinal nerve fiber layer (RNFL) thickness at the macula and head of the optic nerve and Wechsler Adult Intelligence Scale-Revised (WAIS-R) Scores that assess multiple domains of intelligence, and to explore the relationship between changes in the RNFL thickness with intellectual and cognitive dysfunction. A prospective cross-sectional study was conducted at the University Hospital of Kashani, Isfahan, Iran, from September to December 2013. All patients were assessed with a full-scale intelligence quotient (IQ) on the WAIS-R. An optical coherence tomography study and brain MRI were performed in the same week for all the patients. Statistical analysis was conducted by using a bivariate correlation, by utilizing SPSS 20.0. A P value ≤ 0.05 was the threshold of statistical significance. Examination of a 100 patients showed a significant correlation between the average RNFL thickness of the macula and the verbal IQ (P value = 0.01) and full IQ (P value = 0.01). There was a significant correlation between brain atrophy and verbal IQ. The RNFL loss was correlated with verbal IQ and full IQ.
Evaluation of a Myopic Normative Database for Analysis of Retinal Nerve Fiber Layer Thickness.
Biswas, Sayantan; Lin, Chen; Leung, Christopher K S
2016-09-01
Analysis of retinal nerve fiber layer (RNFL) abnormalities with optical coherence tomography in eyes with high myopia has been complicated by high rates of false-positive errors. An understanding of whether the application of a myopic normative database can improve the specificity for detection of RNFL abnormalities in eyes with high myopia is relevant. To evaluate the diagnostic performance of a myopic normative database for detection of RNFL abnormalities in eyes with high myopia (spherical equivalent, -6.0 diopters [D] or less). In this cross-sectional study, 180 eyes with high myopia (mean [SD] spherical equivalent, -8.0 [1.8] D) from 180 healthy individuals were included in the myopic normative database. Another 46 eyes with high myopia from healthy individuals (mean [SD] spherical equivalent, -8.1 [1.8] D) and 74 eyes from patients with high myopia and glaucoma (mean [SD] spherical equivalent, -8.3 [1.9] D) were included for evaluation of specificity and sensitivity. The 95th and 99th percentiles of the mean and clock-hour circumpapillary RNFL thicknesses and the individual superpixel thicknesses of the RNFL thickness map measured by spectral-domain optical coherence tomography were calculated from the 180 eyes with high myopia. Participants were recruited from January 2, 2013, to December 30, 2015. The following 6 criteria of RNFL abnormalities were examined: (1) mean circumpapillary RNFL thickness below the lower 95th or (2) the lower 99th percentile; (3) one clock-hour or more for RNFL thickness below the lower 95th or (4) the lower 99th percentile; and (5) twenty contiguous superpixels or more of RNFL thickness in the RNFL thickness map below the lower 95th or (6) the lower 99th percentile. Specificities and sensitivities for detection of RNFL abnormalities. Of the 46 healthy eyes and 74 eyes with glaucoma studied (from 39 men and 38 women), the myopic normative database showed a higher specificity (63.0%-100%) than did the built-in normative database of the optical coherence tomography instrument (8.7%-87.0%) for detection of RNFL abnormalities across all the criteria examined (differences in specificities between 13.0% [95% CI, 1.1%-24.9%; P = .01] and 54.3% [95% CI, 37.8%-70.9%; P < .001]) except for the criterion of mean RNFL thickness below the lower 99th percentile, in which both normative databases had the same specificities (100%) but the myopic normative database exhibited a higher sensitivity (71.6% vs 86.5%; difference in sensitivities, 14.9% [95% CI, 4.6%-25.1%; P = .002]). The application of a myopic normative database improved the specificity without compromising the sensitivity compared with the optical coherence tomography instrument's built-in normative database for detection of RNFL abnormalities in eyes with high myopia. Inclusion of myopic normative databases should be considered in optical coherence tomography instruments.
Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel
2015-12-01
To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.
2014-01-01
Purpose. Optical coherence tomography (OCT) has been used to investigate papilledema in single-site, mostly retrospective studies. We investigated whether spectral-domain OCT (SD-OCT), which provides thickness and volume measurements of the optic nerve head and retina, could reliably demonstrate structural changes due to papilledema in a prospective multisite clinical trial setting. Methods. At entry, 126 subjects in the Idiopathic Intracranial Hypertension Treatment Trial (IIHTT) with mild visual field loss had optic disc and macular scans, using the Cirrus SD-OCT. Images were analyzed by using the proprietary commercial and custom 3D-segmentation algorithms to calculate retinal nerve fiber layer (RNFL), total retinal thickness (TRT), optic nerve head volume (ONHV), and retinal ganglion cell layer (GCL) thickness. We evaluated variability, with interocular comparison and correlation between results for both methods. Results. The average RNFL thickness > 95% of normal controls in 90% of eyes and the RNFL, TRT, ONH height, and ONHV showed strong (r > 0.8) correlations for interocular comparisons. Variability for repeated testing of OCT parameters was low for both methods and intraclass correlations > 0.9 except for the proprietary GCL thickness. The proprietary algorithm–derived RNFL, TRT, and GCL thickness measurements had failure rates of 10%, 16%, and 20% for all eyes respectively, which were uncommon with 3D-segmentation–derived measurements. Only 7% of eyes had GCL thinning that was less than fifth percentile of normal age-matched control eyes by both methods. Conclusions. Spectral-domain OCT provides reliable continuous variables and quantified assessment of structural alterations due to papilledema. (ClinicalTrials.gov number, NCT01003639.) PMID:25370510
Gabriele, Michelle L.; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Townsend, Kelly A.; Kagemann, Larry; Wojtkowski, Maciej; Srinivasan, Vivek J.; Fujimoto, James G.; Duker, Jay S.; Schuman, Joel S.
2009-01-01
PURPOSE To investigate the effect on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness measurements of varying the standard 3.4-mm-diameter circle location. METHODS The optic nerve head (ONH) region of 17 eyes of 17 healthy subjects was imaged with high-speed, ultrahigh-resolution OCT (hsUHR-OCT; 501 × 180 axial scans covering a 6 × 6-mm area; scan time, 3.84 seconds) for a comprehensive sampling. This method allows for systematic simulation of the variable circle placement effect. RNFL thickness was measured on this three-dimensional dataset by using a custom-designed software program. RNFL thickness was resampled along a 3.4-mm-diameter circle centered on the ONH, then along 3.4-mm circles shifted horizontally (x-shift), vertically (y-shift) and diagonally up to ±500 µm (at 100-µm intervals). Linear mixed-effects models were used to determine RNFL thickness as a function of the scan circle shift. A model for the distance between the two thickest measurements along the RNFL thickness circular profile (peak distance) was also calculated. RESULTS RNFL thickness tended to decrease with both positive and negative x- and y-shifts. The range of shifts that caused a decrease greater than the variability inherent to the commercial device was greater in both nasal and temporal quadrants than in the superior and inferior ones. The model for peak distance demonstrated that as the scan moves nasally, the RNFL peak distance increases, and as the circle moves temporally, the distance decreases. Vertical shifts had a minimal effect on peak distance. CONCLUSIONS The location of the OCT scan circle affects RNFL thickness measurements. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination (ClinicalTrials.gov number, NCT00286637). PMID:18515577
Reznicek, Lukas; Muth, Daniel; Vogel, Michaela; Hirneiß, Christoph
2017-03-01
To evaluate the relationship between functional parameters of repeated flicker-defined form perimetry (FDF) and structural parameters of spectral-domain optical coherence tomography (SD-OCT) in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP). Patients with optic nerve heads (ONH) clinically suspicious for glaucoma and normal SAP findings were enrolled in this prospective study. Each participant underwent visual field (VF) testing with FDF perimetry, using the Heidelberg Edge Perimeter (HEP, Heidelberg Engineering, Heidelberg, Germany) at two consecutive visits. Peripapillary RNFL thickness was obtained by SD-OCT (Spectralis, Heidelberg Engineering, Heidelberg, Germany). Correlations and regression analyses of global and sectoral peripapillary RNFL thickness with corresponding global and regional VF sensitivities were investigated. A consecutive series of 65 study eyes of 36 patients were prospectively included. The second FDF test (HEP II) was used for analysis. Cluster-point based suspicious VF defects were found in 34 eyes (52%). Significant correlations were observed between mean global MD (PSD) of HEP II and SD-OCT-based global peripapillary RNFL thickness (r = 0.380, p = 0.003 for MD and r = -0.516, p < 0.001 for PSD) and RNFL classification scores (R 2 = 0.157, p = 0.002 for MD and R 2 = 0.172, p = 0.001 for PSD). Correlations between mean global MD and PSD of HEP II and sectoral peripapillary RNFL thickness and classification scores showed highest correlations between function and structure for the temporal superior and temporal inferior sectors whereas sectoral MD and PSD correlated weaker with sectoral RNFL thickness. Correlations between linear RNFL values and untransformed logarithmic MD values for each segment were less significant than correlations between logarithmic MD values and RNFL thickness. In glaucoma suspects with normal SAP, global and sectoral peripapillary RNFL thickness is correlated with sensitivity and VF defects in FDF perimetry.
Kim, Ho Soong; Yang, Heon; Lee, Tae Heon; Lee, Kyung Heon
2016-06-01
To determine the diagnostic value of the ganglion cell-inner plexiform layer (GCIPL) thickness in glaucomatous eyes with superior or inferior visual hemifield defects. Eighty-five patients with glaucoma (42 isolated superior hemifield defects and 43 isolated inferior hemifield defects) and 46 normal subjects were enrolled. All patients underwent Cirrus high-definition optical coherence tomography and standard automated perimetry. The area under the receiver operating characteristic curve (AUC) was calculated to determine the diagnostic ability of the GCIPL and peripapillary retinal nerve fiber layer (pRNFL). In the superior hemifield defect glaucoma group, the best parameters for discriminating normal eyes from glaucomatous eyes were the inferotemporal GCIPL thickness (0.942), inferior quadrant RNFL thickness (0.974), and 7 o'clock sector RNFL thickness (0.999). For diagnosing inferior hemifield defect glaucoma, the AUCs of all GCIPL parameters (0.331 to 0.702) were significantly lower than that of the superior quadrant RNFL thickness (0.866, P<0.05). The diagnostic ability of GCIPL parameters was similar to that of the pRNFL parameters in superior hemifield defect glaucoma. However, the diagnostic performance of the GCIPL parameters was significantly inferior to those of the pRNFL parameters in eyes with inferior hemifield defect glaucoma.
Wang, Jui-Kai; Kardon, Randy H.; Kupersmith, Mark J.; Garvin, Mona K.
2012-01-01
Purpose. To develop an automated method for the quantification of volumetric optic disc swelling in papilledema subjects using spectral-domain optical coherence tomography (SD-OCT) and to determine the extent that such volumetric measurements correlate with Frisén scale grades (from fundus photographs) and two-dimensional (2-D) peripapillary retinal nerve fiber layer (RNFL) and total retinal (TR) thickness measurements from SD-OCT. Methods. A custom image-analysis algorithm was developed to obtain peripapillary circular RNFL thickness, TR thickness, and TR volume measurements from SD-OCT volumes of subjects with papilledema. In addition, peripapillary RNFL thickness measures from the commercially available Zeiss SD-OCT machine were obtained. Expert Frisén scale grades were independently obtained from corresponding fundus photographs. Results. In 71 SD-OCT scans, the mean (± standard deviation) resulting TR volumes for Frisén scale 0 to scale 4 were 11.36 ± 0.56, 12.53 ± 1.21, 14.42 ± 2.11, 17.48 ± 2.63, and 21.81 ± 3.16 mm3, respectively. The Spearman's rank correlation coefficient was 0.737. Using 55 eyes with valid Zeiss RNFL measurements, Pearson's correlation coefficient (r) between the TR volume and the custom algorithm's TR thickness, the custom algorithm's RNFL thickness, and Zeiss' RNFL thickness was 0.980, 0.929, and 0.946, respectively. Between Zeiss' RNFL and the custom algorithm's RNFL, and the study's TR thickness, r was 0.901 and 0.961, respectively. Conclusions. Volumetric measurements of the degree of disc swelling in subjects with papilledema can be obtained from SD-OCT volumes, with the mean volume appearing to be roughly linearly related to the Frisén scale grade. Using such an approach can provide a more continuous, objective, and robust means for assessing the degree of disc swelling compared with presently available approaches. PMID:22599584
Retina nerve fiber layer and choroidal thickness changes in obstructive sleep apnea syndrome.
Ozge, Gokhan; Dogan, Deniz; Koylu, Mehmet Talay; Ayyildiz, Onder; Akincioglu, Dorukcan; Mumcuoglu, Tarkan; Mutlu, Fatih Mehmet
2016-01-01
The purpose of this study was to determine the effects of obstructive sleep apnea syndrome (OSAS) on the submacular and peripapillary retinal nerve fiber layer (RNFL) and choroidal thickness (ChT). Eighty-four eyes of 42 male patients with OSAS and 112 eyes of 56 aged-matched and body mass index-matched healthy male subjects were enrolled in this case-control study. The ChT and peripapillary RNFL thickness was measured using enhanced depth imaging optical coherence tomography. The ChT and RNFL thickness measurements of the groups were compared, and correlations among the Apnea Hypopnea Index (AHI) values and these measurements were calculated. Right and left eyes were separately evaluated. There were no significant differences in the subfoveal and temporal ChT between the groups (p > 0.05). The OSAS group had significantly thicker ChT at 0.5 and 1.5 mm nasal to the fovea in both eyes than the control group (p < 0.05). The peripapillary ChT were significantly thicker in the OSAS group at all segments except for the temporal and superotemporal segments when compared with the control group (p < 0.05 for all quadrants except temporal and superotemporal). When compared with controls, the OSAS group had significantly thinner nasal RNFL thickness in the right eye (p = 0.01) and thinner mean RNFL thickness in both eyes (p < 0.001). Other RNFL thickness measurements were similar between groups (p > 0.05). Between AHI and mean RNFL thickness showed a median negative correlation (r = - 0.411, p = 0.001). The choroidal thickening in patients with OSAS may be associated with the pathophysiology of the neurodegeneration process of the disease.
Kuo, Jane Z.; Zangwill, Linda M.; Medeiros, Felipe A.; Liebmann, Jeffery M.; Girkin, Christopher A.; Hammel, Na’ama; Rotter, Jerome I.; Weinreb, Robert N.
2015-01-01
Purpose To perform a quantitative trait locus (QTL) analysis and evaluate whether a locus between SIX1 and SIX6 is associated with retinal nerve fiber layer (RNFL) thickness in individuals of European descent. Design Observational, multi-center, cross-sectional study. Methods 231 participants were recruited from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Association of rs10483727 in SIX1-SIX6 with global and sectoral RNFL thickness was performed. Quantitative trait analysis with the additive model of inheritance was analyzed using linear regression. Trend analysis was performed to evaluate the mean global and sectoral RNFL thickness with 3 genotypes of interest (T/T, C/T, C/C). All models were adjusted for age and gender. Results Direction of association between T allele and RNFL thickness was consistent in the global and different sectoral RNFL regions. Each copy of the T risk allele in rs10483727 was associated with −0.16 μm thinner global RNFL thickness (β=−0.16, 95% CI: −0.28 to −0.03; P=0.01). Similar patterns were found for the sectoral regions, including inferior (P=0.03), inferior-nasal (P=0.017), superior-nasal (P=0.0025), superior (P=0.002) and superior-temporal (P=0.008). The greatest differences were observed in the superior and inferior quadrants, supporting clinical observations for RNFL thinning in glaucoma. Thinner global RNFL was found in subjects with T/T genotypes compared to subjects with C/T and C/C genotypes (P=0.044). Conclusions Each copy of the T risk allele has an additive effect and was associated with thinner global and sectoral RNFL. Findings from this QTL analysis further support a genetic contribution to glaucoma pathophysiology. PMID:25849520
Başkan, Ceyda; Köz, Özlem G; Duman, Rahmi; Gökçe, Sabite E; Yarangümeli, Ahmet A; Kural, Gülcan
2016-12-01
The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension. Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT. Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and Imax/Tavg ratio (P=0.023) and negative correlation with Smax/Navg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05). There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.
Bassi, Shikha Talwar; Mohana, Kuppuswamy Parthasarthy
2014-12-01
To compare the spectral domain optical coherence tomography (SD-OCT) findings of the optic disc and the peripapillary retina of patients with a true papilledema and pseudopapilledema with and without optic nerve head drusen (ONHD). Retrospective Case Control Study. Peripapillary retinal nerve fiber layer (PPRNFL) thickness as depicted by SD-OCT of 94 eyes of 66 patients with papilledema (30 eyes), pseudopapiledema (31 eyes), and normal controls (33 eyes) was analyzed. The mean RNFL thickness, total retinal thickness (TRT) at a superior and inferior edge of the disc and the quadrant wise topography of increased RNFL were compared in all three groups. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) were calculated for all the parameters. The median RNFL thickness was 185.4 (129.5-349.3 μm), 122.3 (109-156.3 μm) and 91.62 ± 7 μm in papilledema, pseudopapilledema, and controls, respectively. Papilledema group had thicker PPRNFL in all quadrants except temporal quadrant. TRT was thicker in papilledema and pseudopapilledema compared to controls. ONHD could be directly visualized as high reflective clumps in the sub-retinal space or the RNFL in 30 eyes. Increased RNFL thickness in all four quadrants was noted 43.3% in papilledema and 9.7% in pseudopapilledema. Normal RNFL thickness in all four quadrants was noted in 0% in papilledema and 32.3% in pseudopapilledema. Nasal RNFL had the highest AROC (0.792) indicating high diagnostic ability to differentiate papilledema from pseudopapilledema. SD-OCT can be used as a tool to differentiate between papilledema and pseudopapilledema.
Retinal architecture and mfERG: Optic nerve head component response characteristics in MS.
Schnurman, Zane S; Frohman, Teresa C; Beh, Shin C; Conger, Darrel; Conger, Amy; Saidha, Shiv; Galetta, Steven; Calabresi, Peter A; Green, Ari J; Balcer, Laura J; Frohman, Elliot M
2014-05-27
To describe a novel neurophysiologic signature of the retinal ganglion cell and to elucidate its relationship to abnormalities in validated structural and functional measures of the visual system. We used multifocal electroretinogram-generated optic nerve head component (ONHC) responses from normal subjects (n = 18), patients with multiple sclerosis (MS) (n = 18), and those with glaucoma (n = 3). We then characterized the relationship between ONHC response abnormalities and performance on low-contrast visual acuity, multifocal visual-evoked potential-induced cortical responses, and average and quadrant retinal nerve fiber layer (RNFL) thicknesses, as measured by spectral-domain optical coherence tomography. Compared with the eyes of normal subjects, the eyes of patients with MS exhibited an increased number of abnormal or absent ONHC responses (p < 0.0001). For every 7-letter reduction in low-contrast letter acuity, there were corresponding 4.6 abnormal ONHC responses at 2.5% contrast (p < 0.0001) and 6.6 abnormalities at the 1.25% contrast level (p < 0.0001). Regarding average RNFL thickness, for each 10-μm thickness reduction, we correspondingly observed 6.8 abnormal ONHC responses (p = 0.0002). The most robust association was between RNFL thinning in the temporal quadrant and ONHC response abnormalities (p < 0.0001). Further characterization of ONHC abnormalities (those that are reversible and irreversible) may contribute to the development of novel neurotherapeutic strategies aimed at achieving neuroprotective, and perhaps even neurorestorative, effects in disorders that target the CNS in general, and MS in particular. © 2014 American Academy of Neurology.
Pazos, Marta; Dyrda, Agnieszka Anna; Biarnés, Marc; Gómez, Alicia; Martín, Carlos; Mora, Clara; Fatti, Gianluca; Antón, Alfonso
2017-08-01
To evaluate the accuracy of the macular retinal layer segmentation software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany) to discriminate between healthy and early glaucoma (EG) eyes. Prospective, cross-sectional study. Forty EG eyes and 40 healthy controls were included. All participants were examined using the standard posterior pole and the peripapillary retinal nerve fiber layer (pRNFL) protocols of the Spectralis OCT device. Using an Early Treatment Diagnostic Retinopathy Study circle at the macular level, the automated retinal segmentation software was applied to determine thicknesses of the following parameters: total retinal thickness, inner retinal layer (IRL), macular retinal nerve fiber layer (mRNFL), macular ganglion cell layer (mGCL), macular inner plexiform layer (mIPL), macular inner nuclear layer (mINL), macular outer plexiform layer (mOPL), macular outer nuclear layer (mONL), photoreceptors (PR), and retinal pigmentary epithelium (RPE). The ganglion cell complex (GCC) was determined by adding the mRNFL, mGCL, and mIPL parameters and the ganglion cell layer-inner plexiform layer (mGCL-IPL) was determined by combining the mGCL and mIPL parameters. Thickness of each layer was compared between the groups, and the layer and sector with the best area under the receiver operating characteristic curve (AUC) were identified. Comparison of pRNFL, IRL, mRNFL, mGCL, mIPL, mGCC, mGCL-IPL, mINL, mOPL, mONL, PR, and RPE parameters and total retinal thicknesses between groups for the different areas and their corresponding AUCs. Peripapillary RNFL was significantly thinner in the EG group globally and in all 6 sectors assessed (P < 0.0005). For the macular variables, retinal thickness was significantly reduced in the EG group for total retinal thickness, mIRL, mRNFL, mGCL, and mIPL. The 2 best isolated parameters to discriminate between the 2 groups were pRNFL (AUC, 0.956) and mRNFL (AUC, 0.906). When mRNFL, mGCL, and mIPL measurements were combined (mGCC and mGCL plus mIPL), then its diagnostic performance improved (AUC, 0.940 and 0.952, respectively). Macular RNFL, mGCL-IPL, and mGCC measurements showed a high diagnostic capability to discriminate between healthy and EG participants. However, macular intraretinal measurements still have not overcome standard pRNFL parameters. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Sehi, Mitra; Greenfield, David S.
2006-01-01
Purpose To describe a case of progressive glaucomatous optic neuropathy using scanning laser polarimetry with fixed (SLP-FCC) and variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT). Design Observational case report. Methods A 21-year-old male with juvenile primary open-angle glaucoma developed progression because of noncompliance with therapy. The patient underwent dilated stereoscopic examination and photography of the optic disk, standard automated perimetry (SAP), OCT, and SLP imaging with FCC and VCC at the baseline examination and after four years of follow-up. Results Optic disk, retinal nerve fiber layer (RNFL) atrophy, and SAP progression was observed. Reduction in mean RNFL thickness (average, superior, inferior) was 18, 18, and 27 microns (OCT); 22, 40, and 17 microns (SLP-FCC); and 6, 12, and 12 microns (SLP-VCC), respectively. Conclusions This case demonstrates that digital imaging of the peripapillary RNFL is capable of documentation and measurement of progressive glaucomatous RNFL atrophy. PMID:17157591
Lee, Won June; Na, Kyeong Ik; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-06-01
To evaluate the diagnostic ability of wide-field retinal nerve fiber layer (RNFL) maps with swept-source optical coherence tomography (SS-OCT) for detection of preperimetric (PPG) and early perimetric glaucoma (EG). One hundred eighty-four eyes, including 67 healthy eyes, 43 eyes with PPG, and 74 eyes with EG, were analyzed. Patients underwent a comprehensive ocular examination including red-free RNFL photography, visual field testing and wide-field SS-OCT scanning (DRI-OCT-1 Atlantis; Topcon, Tokyo, Japan). SS-OCT provides a wide-field RNFL thickness map and a SuperPixel map, which are composed of the RNFL deviation map of the peripapillary area and the deviation map of the composition of the ganglion cell layer with the inner plexiform layer and RNFL (GC-IPL+RNFL) in the macular area. The ability to discriminate PPG and EG from healthy eyes was assessed using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for all parameters and criteria provided by the wide-field SS-OCT scan. The wide-field RNFL thickness map using SS-OCT showed the highest sensitivity of PPG-diagnostic and EG-diagnostic performance compared with the other SS-OCT criteria based on the internal normative base (93.0 and 97.3%, respectively). Among the SS-OCT continuous parameters, the RFNL thickness of the 7 clock-hour, inferior and inferotemporal macular ganglion cell analyses showed the largest AUC of PPG-diagnostic and EG-diagnostic performance (AUC=0.809 to 0.865). The wide-field RNFL thickness map using SS-OCT performed well in distinguishing eyes with PPG and EG from healthy eyes. In the clinical setting, wide-field RNFL maps of SS-OCT can be useful tools for detection of early-stage glaucoma.
Seol, Bo Ram; Kim, Dong Myung; Park, Ki Ho; Jeoung, Jin Wook
2017-11-01
To evaluate the optical coherence tomography (OCT) color probability codes based on a myopic normative database and to investigate whether the implementation of the myopic normative database can improve the OCT diagnostic ability in myopic glaucoma. Comparative validity study. In this study, 305 eyes (154 myopic healthy eyes and 151 myopic glaucoma eyes) were included. A myopic normative database was obtained based on myopic healthy eyes. We evaluated the agreement between OCT color probability codes after applying the built-in and myopic normative databases, respectively. Another 120 eyes (60 myopic healthy eyes and 60 myopic glaucoma eyes) were included and the diagnostic performance of OCT color codes using a myopic normative database was investigated. The mean weighted kappa (Kw) coefficients for quadrant retinal nerve fiber layer (RNFL) thickness, clock-hour RNFL thickness, and ganglion cell-inner plexiform layer (GCIPL) thickness were 0.636, 0.627, and 0.564, respectively. The myopic normative database showed a higher specificity than did the built-in normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P < .001, P < .001, and P < .001, respectively). The receiver operating characteristic curve values increased when using the myopic normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P = .011, P = .004, P < .001, respectively). The diagnostic ability of OCT color codes for detection of myopic glaucoma significantly improved after application of the myopic normative database. The implementation of a myopic normative database is needed to allow more precise interpretation of OCT color probability codes when used in myopic eyes. Copyright © 2017 Elsevier Inc. All rights reserved.
Sousa, Rafael M; Oyamada, Maria K; Cunha, Leonardo P; Monteiro, Mário L R
2017-09-01
To verify whether multifocal visual evoked potential (mfVEP) can differentiate eyes with temporal hemianopia due to chiasmal compression from healthy controls. To assess the relationship between mfVEP, standard automated perimetry (SAP), and Fourier domain-optical coherence tomography (FD-OCT) macular and peripapillary retinal nerve fiber layer (RNFL) thickness measurements. Twenty-seven eyes with permanent temporal visual field (VF) defects from chiasmal compression on SAP and 43 eyes of healthy controls were submitted to mfVEP and FD-OCT scanning. Multifocal visual evoked potential was elicited using a stimulus pattern of 60 sectors and the responses were averaged for the four quadrants and two hemifields. Optical coherence tomography macular measurements were averaged in quadrants and halves, while peripapillary RNFL thickness was averaged in four sectors around the disc. Visual field loss was estimated in four quadrants and each half of the 24-2 strategy test points. Multifocal visual evoked potential measurements in the two groups were compared using generalized estimated equations, and the correlations between mfVEP, VF, and OCT findings were quantified. Multifocal visual evoked potential-measured temporal P1 and N2 amplitudes were significantly smaller in patients than in controls. No significant difference in amplitude was observed for nasal parameters. A significant correlation was found between mfVEP amplitudes and temporal VF loss, and between mfVEP amplitudes and the corresponding OCT-measured macular and RNFL thickness parameters. Multifocal visual evoked potential amplitude parameters were able to differentiate eyes with temporal hemianopia from controls and were significantly correlated with VF and OCT findings, suggesting mfVEP is a useful tool for the detection of visual abnormalities in patients with chiasmal compression.
Bassi, Shikha Talwar; Mohana, Kuppuswamy Parthasarthy
2014-01-01
Aim: To compare the spectral domain optical coherence tomography (SD-OCT) findings of the optic disc and the peripapillary retina of patients with a true papilledema and pseudopapilledema with and without optic nerve head drusen (ONHD). Study Design: Retrospective Case Control Study. Subjects and Methods: Peripapillary retinal nerve fiber layer (PPRNFL) thickness as depicted by SD-OCT of 94 eyes of 66 patients with papilledema (30 eyes), pseudopapiledema (31 eyes), and normal controls (33 eyes) was analyzed. The mean RNFL thickness, total retinal thickness (TRT) at a superior and inferior edge of the disc and the quadrant wise topography of increased RNFL were compared in all three groups. Sensitivity, specificity, and area under the receiver operating characteristic curve (AROC) were calculated for all the parameters. Results: The median RNFL thickness was 185.4 (129.5–349.3 μm), 122.3 (109–156.3 μm) and 91.62 ± 7 μm in papilledema, pseudopapilledema, and controls, respectively. Papilledema group had thicker PPRNFL in all quadrants except temporal quadrant. TRT was thicker in papilledema and pseudopapilledema compared to controls. ONHD could be directly visualized as high reflective clumps in the sub-retinal space or the RNFL in 30 eyes. Increased RNFL thickness in all four quadrants was noted 43.3% in papilledema and 9.7% in pseudopapilledema. Normal RNFL thickness in all four quadrants was noted in 0% in papilledema and 32.3% in pseudopapilledema. Nasal RNFL had the highest AROC (0.792) indicating high diagnostic ability to differentiate papilledema from pseudopapilledema. Conclusion: SD-OCT can be used as a tool to differentiate between papilledema and pseudopapilledema. PMID:25579359
Khoueir, Ziad; Jassim, Firas; Poon, Linda Yi-Chieh; Tsikata, Edem; Ben-David, Geulah S; Liu, Yingna; Shieh, Eric; Lee, Ramon; Guo, Rong; Papadogeorgou, Georgia; Braaf, Boy; Simavli, Huseyin; Que, Christian; Vakoc, Benjamin J; Bouma, Brett E; de Boer, Johannes F; Chen, Teresa C
2017-10-01
To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral-domain optical coherence tomography (OCT) volume scans for open-angle glaucoma (OAG). Assessment of diagnostic accuracy. Setting: Academic clinical setting. Total of 180 patients (113 OAG and 67 normal subjects). One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using 4 different-size annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios. Among all 2D and 3D RNFL parameters, best diagnostic capability was associated with inferior quadrant 3D RNFL volume of the smallest annulus (AUROC value 0.977). Otherwise, global 3D RNFL volume AUROC values were comparable to global 2D RNFL thickness AUROC values for all 4 annulus sizes (P values: .0593 to .6866). When comparing the 4 annulus sizes for global RNFL volume, the smallest annulus had the best AUROC values (P values: .0317 to .0380). The smallest-size annulus may have the best diagnostic potential, partly owing to having no areas excluded for being larger than the 6 × 6 mm 2 scanned region. Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma. Peripapillary 3D RNFL volume parameters have the same or better diagnostic capability compared to peripapillary 2D RNFL thickness measurements, although differences were not statistically significant. Copyright © 2017 Elsevier Inc. All rights reserved.
Carpineto, P; Toto, L; Aloia, R; Ciciarelli, V; Borrelli, E; Vitacolonna, E; Di Nicola, M; Di Antonio, L; Mastropasqua, R
2016-05-01
PurposeTo study neuroretinal alterations in patients affected by type 2 diabetes with no diabetic retinopathy (DR) or mild nonproliferative diabetic retinopathy (NPDR) and without any sign of diabetic macular edema.Patients and methodsIn total, 150 type 2 diabetic patients with no (131 eyes) or mild NPDR (19 eyes) and 50 healthy controls were enrolled in our study. All underwent a complete ophthalmologic examination, including Spectral-Domain optical coherence tomography (SD-OCT). Ganglion cell-inner plexiform layer (GC-IPL) and retinal nerve fiber layer (RNFL) thickness values were calculated after automated segmentation of SD-OCT scans.ResultsMean best-corrected visual acuity was 0.0±0.0 LogMAR in all the groups. Mean GC-IPL thickness was 80.6±8.1 μm in diabetic patients and 85.3±9.9 μm in healthy controls, respectively (P=0.001). Moreover, evaluating the two different diabetic groups, GC-IPL thickness was 80.7±8.1 μm and 79.7±8.8 μm in no-DR and mild-NPDR group (P=0.001 and P=0.022 compared with healthy controls, respectively). Average RNFL thickness was 86.1±10.1 μm in diabetes patients and 91.2±7.3 μm in controls, respectively (P=0.003). RNFL thickness was 86.4±10.2 μm in no-DR group and 84.1±9.4 μm in mild-NPDR group (P=0.007 and P=0.017 compared with healthy controls, respectively).ConclusionWe demonstrated a significantly reduced GC-IPL and RNFL thickness values in both no-DR and mild-NPDR groups compared with healthy controls. These data confirmed neuroretinal alterations are early in diabetes, preceding microvascular damages.
Sung, Mi-Sun; Kang, Byung-Wan; Kim, Hwang-Gyun; Heo, Hwan; Park, Sang-Woo
2014-08-01
To evaluate the repeatability and diagnostic power of macular ganglion cell complex (mGCC) thickness and peripapillary retinal nerve fiber layer (pRNFL) thickness using a spectral domain-optical coherence tomography in advanced glaucoma. Forty advanced glaucoma patients were enrolled. Patients were divided into 2 groups of 20 patients each, according to the MD between -20 and -10 dB, and <-20 dB. The thickness of mGCC and pRNFL were measured with spectral domain-optical coherence tomography in both the groups. The repeatability of each parameter was assessed in both the groups, and the diagnostic power of each parameter was compared with the normal controls. Comparison of diagnostic power between the pRNFL and mGCC parameters revealed that the area under the receiver operating characteristic curve was not significantly different in patients with advanced glaucoma. The repeatability of pRNFL parameters was similar, irrespective of the severity of glaucoma. However, the repeatability of mGCC parameters became lower as the severity increased in patients with advanced glaucoma. In advanced glaucoma, the measurement of mGCC thickness has similar diagnostic power as the measurement of pRNFL thickness. However, the measurement of mGCC thickness showed a lower repeatability as MD decreased.
Stemplewitz, Birthe; Kromer, Robert; Vettorazzi, Eik; Hidding, Ute; Frings, Andreas; Buhmann, Carsten
2017-07-13
This cross-sectional study compared the retinal morphology between patients with progressive supranuclear palsy (PSP) and healthy controls. (The retinal nerve fiber layer (RNFL) around the optic disc and the retina in the macular area of 22 PSP patients and 151 controls were investigated by spectral domain optical coherence tomography (SD-OCT). Additionally, the RNFL and the nerve fiber index (NFI) were measured by scanning laser polarimetry (SLP). Results of RNFL measurements with SD-OCT and SLP were compared to assess diagnostic discriminatory power. Applying OCT, PSP patients showed a smaller RNFL thickness in the inferior nasal and inferior temporal areas. The macular volume and the thickness of the majority of macular sectors were reduced compared to controls. SLP data showed a thinner RNFL thickness and an increase in the NFI in PSP patients. Sensitivity and specificity to discriminate PSP patients from controls were higher applying SLP than SD-OCT. Retinal changes did not correlate with disease duration or severity in any OCT or SLP measurement. PSP seems to be associated with reduced thickness and volume of the macula and reduction of the RNFL, independent of disease duration or severity. Retinal imaging with SD-OCT and SLP might become an additional tool in PSP diagnosis.
Malik, Rizwan; Belliveau, Anne C; Sharpe, Glen P; Shuba, Lesya M; Chauhan, Balwantray C; Nicolela, Marcelo T
2016-06-01
Ruling out glaucoma in myopic eyes often poses a diagnostic challenge because of atypical optic disc morphology and visual field defects that can mimic glaucoma. We determined whether neuroretinal rim assessment based on Bruch's membrane opening (BMO), rather than conventional optic disc margin (DM)-based assessment or retinal nerve fiber layer (RNFL) thickness, yielded higher diagnostic accuracy in myopic patients with glaucoma. Case-control, cross-sectional study. Myopic patients with glaucoma (n = 56) and myopic normal controls (n = 74). Myopic subjects with refraction error greater than -2 diopters (D) (spherical equivalent) and typical myopic optic disc morphology, with and without glaucoma, were recruited from a glaucoma clinic and a local optometry practice. The final classification of myopic glaucoma or myopic control was based on consensus assessment by 3 clinicians of visual fields and optic disc photographs. Participants underwent imaging with confocal scanning laser tomography for measurement of DM rim area (DM-RA) and with spectral domain optical coherence tomography (SD OCT) for quantification of a BMO-based neuroretinal rim parameter, minimum rim width (BMO-MRW), and RNFL thickness. Sensitivity of DM-RA, BMO-MRW, and RNFL thickness at a fixed specificity of 90% and partial area under the curves (pAUCs) for global and sectoral parameters for specificities ≥90%. Sensitivities at 90% specificity were 30% for DM-RA and 71% for both BMO-MRW and RNFL thickness. The pAUC was higher for the BMO-MRW compared with DM-RA (P < 0.001), but similar to RNFL thickness (P > 0.5). Sectoral values of BMO-MRW tended to have a higher, but nonsignificant, pAUC across all sectors compared with RNFL thickness. Bruch's membrane opening MRW is more sensitive than DM-RA and similar to RNFL thickness for the identification of glaucoma in myopic eyes and offers a valuable diagnostic tool for patients with glaucoma with myopic optic discs. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Bowd, Christopher; Medeiros, Felipe A.; Zhang, Zuohua; Zangwill, Linda M.; Hao, Jiucang; Lee, Te-Won; Sejnowski, Terrence J.; Weinreb, Robert N.; Goldbaum, Michael H.
2010-01-01
Purpose To classify healthy and glaucomatous eyes using relevance vector machine (RVM) and support vector machine (SVM) learning classifiers trained on retinal nerve fiber layer (RNFL) thickness measurements obtained by scanning laser polarimetry (SLP). Methods Seventy-two eyes of 72 healthy control subjects (average age = 64.3 ± 8.8 years, visual field mean deviation =−0.71 ± 1.2 dB) and 92 eyes of 92 patients with glaucoma (average age = 66.9 ± 8.9 years, visual field mean deviation =−5.32 ± 4.0 dB) were imaged with SLP with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, San Diego, CA). RVM and SVM learning classifiers were trained and tested on SLP-determined RNFL thickness measurements from 14 standard parameters and 64 sectors (approximately 5.6° each) obtained in the circumpapillary area under the instrument-defined measurement ellipse (total 78 parameters). Tenfold cross-validation was used to train and test RVM and SVM classifiers on unique subsets of the full 164-eye data set and areas under the receiver operating characteristic (AUROC) curve for the classification of eyes in the test set were generated. AUROC curve results from RVM and SVM were compared to those for 14 SLP software-generated global and regional RNFL thickness parameters. Also reported was the AUROC curve for the GDx VCC software-generated nerve fiber indicator (NFI). Results The AUROC curves for RVM and SVM were 0.90 and 0.91, respectively, and increased to 0.93 and 0.94 when the training sets were optimized with sequential forward and backward selection (resulting in reduced dimensional data sets). AUROC curves for optimized RVM and SVM were significantly larger than those for all individual SLP parameters. The AUROC curve for the NFI was 0.87. Conclusions Results from RVM and SVM trained on SLP RNFL thickness measurements are similar and provide accurate classification of glaucomatous and healthy eyes. RVM may be preferable to SVM, because it provides a Bayesian-derived probability of glaucoma as an output. These results suggest that these machine learning classifiers show good potential for glaucoma diagnosis. PMID:15790898
Diagnostic Capability of Spectral Domain Optical Coherence Tomography for Glaucoma
Wu, Huijuan; de Boer, Johannes F.; Chen, Teresa C.
2012-01-01
Purpose To determine the diagnostic capability of spectral domain optical coherence tomography (OCT) in glaucoma patients with visual field (VF) defects. Design Prospective, cross-sectional study. Methods Setting Participants were recruited from a university hospital clinic. Study Population One eye of 85 normal subjects and 61 glaucoma patients [with average VF mean deviation (MD) of -9.61 ± 8.76 dB] were randomly selected for the study. A subgroup of the glaucoma patients with early VF defects was calculated separately. Observation Procedures Spectralis OCT circular scans were performed to obtain peripapillary retinal nerve fiber layer (RNFL) thicknesses. The RNFL diagnostic parameters based on the normative database were used alone or in combination for identifying glaucomatous RNFL thinning. Main Outcome Measures To evaluate diagnostic performance, calculations included areas under the receiver operating characteristic curve (AROC), sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio. Results Overall RNFL thickness had the highest AROC value (0.952 for all patients, 0.895 for the early glaucoma subgroup). For all patients, the highest sensitivity (98.4%, CI 96.3-100%) was achieved by using two criteria: ≥1 RNFL sectors being abnormal at the < 5% level, and overall classification of borderline or outside normal limits, with specificities of 88.9% (CI 84.0-94.0%) and 87.1% (CI 81.6-92.5%) respectively for these two criteria. Conclusions Statistical parameters for evaluating the diagnostic performance of the Spectralis spectral domain OCT were good for early perimetric glaucoma and excellent for moderately-advanced perimetric glaucoma. PMID:22265147
Xue, Kang; Wang, Min; Chen, Junyi; Huang, Xin; Xu, Gezhi
2013-01-01
To measure the thickness of the retinal nerve fiber layer (RNFL) of patients with retinitis pigmentosa (RP) and that of normal controls by scanning laser polarimetry with enhanced corneal compensation (GDxECC) and RTVue-optical coherence tomography (OCT). Fifty-two eyes of 26 patients were included. All patients underwent complete ophthalmological examinations and testing with GDxECC. Twenty-eight of 52 eyes of RP patients underwent RTVue-OCT measurements. A group of 50 eyes of 25 normal subjects (controls) was also included. GDxECC measured RNFL thickness in the peripapillary area in all subjects as well as temporal-superior-nasal-inferior-temporal (TSNIT) parameters, including TSNIT means, superior and inferior region means, TSNIT standard deviation (SD), inter-eye symmetry and nerve fiber indicator (NFI). RTVue-OCT measured the mean, superior, inferior, temporal and nasal quadrant RNFL thickness. In RP patients and controls, TSNIT means by GDxECC were, respectively, 65.00 ± 7.35 and 55.32 ± 5.20. Mean superior quadrant thicknesses were 80.56 ± 10.93 and 69.54 ± 7.45. Mean inferior thicknesses were 80.58 ± 9.34 and 69.12 ± 7.78. SDs were 27.92 ± 5.21 and 28.23 ± 4.01. Inter-eye symmetries were 0.82 ± 0.17 and 0.87 ± 0.09. NFIs were 9.74 ± 8.73 and 16.81 ± 8.13. The differences between mean TSNIT, mean superior and mean inferior quadrant thicknesses and NFIs were statistically significant (p < 0.001). In RTVue-OCT measurements, the differences between mean, superior, inferior and temporal quadrant RNFL thicknesses were statistically significant (p = 0.0322, 0.0213, 0.0387, 0.0005). The RNFL measured by GDxECC was significantly thicker in RP patients than in controls. RNFL thickness measured by RTVue-OCT was significantly greater in RP patients than in controls in the superior, inferior and temporal regions. This contribution provides information on RNFL thickness and discusses the mechanism underlying this phenomenon. Copyright © 2012 S. Karger AG, Basel.
Grundy, Sara J; Tshering, Lhab; Wanjala, Stanley W; Diamond, Megan B; Audi, Martin S; Prasad, Sashank; Shinohara, Russell T; Rogo, Debora; Wangmo, Dechen; Wangdi, Ugyen; Aarayang, Abi; Tshering, Thukten; Burke, Thomas F; Mateen, Farrah J
2018-06-11
The retina shares embryological derivation with the brain and may provide a new measurement of overall growth status, especially useful in resource-limited settings. Optical coherence tomography (OCT) provides detailed quantification of retinal structures. We enrolled community-dwelling children ages 3-11 years old in Siaya, Kenya and Thimphu, Bhutan in 2016. We measured head circumference (age < 5 years only), height, and weight, and standardized these by age and gender. Research staff performed OCT ( iScan ; Optovue, Inc., Fremont, CA), measuring the peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell complex (GCC) thicknesses. A neuro-ophthalmologist performed quality control for centration, motion artifact, and algorithm-derived quality scores. Generalized estimating equations were used to determine the relationship between anthropometric and retinal measurements. Two hundred and fifty-eight children (139 females, average age 6.4 years) successfully completed at least one retinal scan, totaling 1,048 scans. Nine hundred and twenty-two scans (88.0%) were deemed usable. Fifty-three of the 258 children (20.5%) were able to complete all six scans. Kenyan children had a thinner average GCC ( P < 0.001) than Bhutanese children after adjustment for age and gender, but not RNFL ( P = 0.70). In models adjusting for age, gender, and study location, none of standardized height, weight, and body mass index (BMI) were statistically significantly associated with RNFL or GCC. We determined that OCT is feasible in some children in resource-limited settings, particularly those > 4 years old, using the iScan device. We found no evidence for GCC or RNFL as a proxy for height-, weight-, or BMI-for-age. The variation in mean GCC thickness in Asian versus African children warrants further investigation.
Rao, Harsha L; Addepalli, Uday K; Yadav, Ravi K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2014-03-01
To evaluate the effect of scan quality on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) parameters of spectral-domain optical coherence tomography (SD OCT) in glaucoma. Cross-sectional study. Two hundred fifty-two eyes of 183 control subjects (mean deviation [MD]: -1.84 dB) and 207 eyes of 159 glaucoma patients (MD: -7.31 dB) underwent ONH, RNFL, and GCC scanning with SD OCT. Scan quality of SD OCT images was based on signal strength index (SSI) values. Influence of SSI on diagnostic accuracy of SD OCT was evaluated by receiver operating characteristic (ROC) regression. Diagnostic accuracies of all SD OCT parameters were better when the SSI values were higher. This effect was statistically significant (P < .05) for ONH and RNFL but not for GCC parameters. In mild glaucoma (MD of -5 dB), area under ROC curve (AUC) for rim area, average RNFL thickness, and average GCC thickness parameters improved from 0.651, 0.678, and 0.726, respectively, at an SSI value of 30 to 0.873, 0.962, and 0.886, respectively, at an SSI of 70. AUCs of the same parameters in advanced glaucoma (MD of -15 dB) improved from 0.747, 0.890, and 0.873, respectively, at an SSI value of 30 to 0.922, 0.994, and 0.959, respectively, at an SSI of 70. Diagnostic accuracies of SD OCT parameters in glaucoma were significantly influenced by the scan quality even when the SSI values were within the manufacturer-recommended limits. These results should be considered while interpreting the SD OCT scans for glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.
Rao, Harsha L; Venkatesh, Chirravuri R; Vidyasagar, Kelli; Yadav, Ravi K; Addepalli, Uday K; Jude, Aarthi; Senthil, Sirisha; Garudadri, Chandra S
2014-12-01
To evaluate the (i) effects of biological (age and axial length) and instrument-related [typical scan score (TSS) and corneal birefringence] parameters on the retinal nerve fiber layer (RNFL) measurements and (ii) repeatability of RNFL measurements with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in healthy subjects. In a cross-sectional study, 140 eyes of 73 healthy subjects underwent RNFL imaging with the ECC protocol of SLP. Linear mixed modeling methods were used to evaluate the effects of age, axial length, TSS, and corneal birefringence on RNFL measurements. One randomly selected eye of 48 subjects from the cohort underwent 3 serial scans during the same session to determine the repeatability. Age significantly influenced all RNFL measurements. RNFL measurements decreased by 1 µm for every decade increase in age. TSS affected the overall average RNFL measurement (β=-0.62, P=0.003), whereas residual anterior segment retardance affected the superior quadrant measurement (β=1.14, P=0.01). Axial length and corneal birefringence measurements did not influence RNFL measurements. Repeatability, as assessed by the coefficient of variation, ranged between 1.7% for the overall average RNFL measurement and 11.4% for th nerve fiber indicator. Age significantly affected all RNFL measurements with the ECC protocol of SLP, whereas TSS and residual anterior segment retardance affected the overall average and the superior average RNFL measurements, respectively. Axial length and corneal birefringence measurements did not influence any RNFL measurements. RNFL measurements had good intrasession repeatability. These results are important while evaluating the change in structural measurements over time in glaucoma patients.
Hua, Zanmei; Fang, Qiuyun; Sha, Xiangyin; Yang, Ruiming; Hong, Zuopeng
2015-03-01
Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography (OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters. A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer (RNFL) thickness and the optic disc tomography by spectral-domain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma (POAG). This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control (n = 51, 98 eyes), suspected glaucoma (n = 81, 146 eyes), and POAG groups (n = 55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness, disc area (DA), cup area (CA), rim area (RA), disc volume (DV), cup volume (CV), rim volume (RV), cup/disc area ratio (CA/DA), rim/disc area ratio (RA/DA), cup/disc volume ratio (CV/DV) and rim/disc volume ratio (RV/DV). Superior, nasal, and mean RNFL parameters, DA, CA,RA, DV, CV, CA/DA, RA/DA, CV/DV and RV/DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group, the maximum area under the ROC curve (AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA/DA (0.998), followed by CA/DA (0.997). The AROC of CA, RA, CV, and DV were all > 0.900. OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG.
Yoon, Chang Ki; Yu, Hyeong Gon
2018-03-01
To investigate how macular ganglion cell-inner plexiform layer (GCIPL) and retinal nerve fibre layer (RNFL) thicknesses within the macula change with retinitis pigmentosa (RP) severity. Spectral domain optical coherence tomography (SD-OCT) was used to examine 177 patients with RP and 177 normal controls. An optical coherence tomography (OCT) line scan was used to grade RP severity. Retinitis pigmentosa (RP) was categorized as more advanced if there was no identifiable inner segment ellipsoid (ISe) band (NISE) and as less advanced if an ISe band could be identified and peripheral loss of ISe was apparent (IISE). Ganglion cell-inner plexiform layer (GCIPL) and RNFL thicknesses were manually measured on OCT images and analysed. Pearson's correlation analyses were used to examine correlations between GCIPL thickness, RNFL thickness, visual acuity (VA) and visual field extent in patients and controls. Ganglion cell-inner plexiform layer (GCIPL) was significantly thicker in IISE than in control eyes (p < 0.001), but significantly thinner in NISE than in IISE eyes (p < 0.001) in both horizontal and vertical OCT scans. Retinal nerve fibre layer (RNFL) was significantly thicker in eyes with IISE and NISE than in control eyes in both horizontal and vertical meridians (all p < 0.001). Ganglion cell-inner plexiform layer (GCIPL) thickness showed a weak positive correlation with vision, and RNFL thickness showed a weak negative correlation with vision and visual field extent. Based on these results, the inner retina, including the GCIPL and RNFL, maintains its gross integrity longer than the photoreceptor layer in RP. Additionally, thickening of the inner retina may have some functional implications in patients with RP. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Tsikata, Edem; Lee, Ramon; Shieh, Eric; Simavli, Huseyin; Que, Christian J.; Guo, Rong; Khoueir, Ziad; de Boer, Johannes; Chen, Teresa C.
2016-01-01
Purpose To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. Methods Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-μm reference surface–based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. Results The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-μm reference surface had diagnostic capabilities similar to RNFL thickness. Conclusions The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors. PMID:27768203
Gulmez Sevim, Duygu; Unlu, Metin; Gultekin, Murat; Karaca, Cagatay
2018-02-12
There have been ongoing clinical trials of therapeutic agents in Huntington's disease (HD) which requires development of reliable biomarkers of disease progression. There have been studies in the literature with conflicting results on the involvement of retina in HD, and up to date there is not a study evaluating the single retinal layers in HD. We aimed to evaluate the specific retinal changes in HD and their usability as potential disease progression markers. This cross-sectional study used spectral-domain optical coherence tomography with automatic segmentation to measure peripapillary retinal nerve fiber layer (pRNFL) thickness and the thickness and volume of retinal layers in foveal scans of 15 patients with HD and 15 age- and sex-matched controls. Genetic testing results, disease duration, HD disease burden scores and Unified HD Rating Scales motor scores were acquired for the patients. Temporal pRNFL, macular RNFL (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer and outer plexiform layer thicknesses and IPL, retinal pigment epithelium and outer macular volume were found lower in HD compared to controls, while outer nuclear layer and outer retinal layer thickness were increased (p < 0.05). We found significant correlations between inner retinal layer thicknesses, most significantly with mRNFL and GCL and disease progression markers. The outcomes of this study points out that retinal layers, most significantly mRNFL and GCL, are strongly correlated with the disease progression in HD and could serve as useful biomarkers for disease progression.
Diagnostic capability of spectral-domain optical coherence tomography for glaucoma.
Wu, Huijuan; de Boer, Johannes F; Chen, Teresa C
2012-05-01
To determine the diagnostic capability of spectral-domain optical coherence tomography in glaucoma patients with visual field defects. Prospective, cross-sectional study. Participants were recruited from a university hospital clinic. One eye of 85 normal subjects and 61 glaucoma patients with average visual field mean deviation of -9.61 ± 8.76 dB was selected randomly for the study. A subgroup of the glaucoma patients with early visual field defects was calculated separately. Spectralis optical coherence tomography (Heidelberg Engineering, Inc) circular scans were performed to obtain peripapillary retinal nerve fiber layer (RNFL) thicknesses. The RNFL diagnostic parameters based on the normative database were used alone or in combination for identifying glaucomatous RNFL thinning. To evaluate diagnostic performance, calculations included areas under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio. Overall RNFL thickness had the highest area under the receiver operating characteristic curve values: 0.952 for all patients and 0.895 for the early glaucoma subgroup. For all patients, the highest sensitivity (98.4%; 95% confidence interval, 96.3% to 100%) was achieved by using 2 criteria: ≥ 1 RNFL sectors being abnormal at the < 5% level and overall classification of borderline or outside normal limits, with specificities of 88.9% (95% confidence interval, 84.0% to 94.0%) and 87.1% (95% confidence interval, 81.6% to 92.5%), respectively, for these 2 criteria. Statistical parameters for evaluating the diagnostic performance of the Spectralis spectral-domain optical coherence tomography were good for early perimetric glaucoma and were excellent for moderately advanced perimetric glaucoma. Copyright © 2012 Elsevier Inc. All rights reserved.
Qiao, Nidan; Ye, Zhao; Shou, Xuefei; Wang, Yongfei; Li, Shiqi; Wang, Min; Zhao, Yao
2016-12-01
The relationship between functional and structural measurements is of fundamental importance in monitoring treatment and progression in patients with pituitary adenoma. In the present study, we examined the association between longitudinal changes in standard automated perimetry (SAP), retinal nerve fiber layer (RNFL) thickness and multifocal visual evoked potential (mfVEP) amplitude after transsphenoidal surgery. Thirty patients with pituitary adenoma were recruited from Huashan Hospital between September 2010 and January 2014. The examination included pupil examination, anterior and posterior segment examination, SAP, RNFL and mfVEP. At three months and nine months after transsphenoid surgery, follow-up measurements were conducted in twenty-three patients, and at 18 months after surgery, the same examinations were performed in seven patients. The average age of patients was 42.6±12.1years, with 23 males and 7 females. The mean score of SAP improved significantly: 1.75 before surgery; 0.62 at three months after surgery (p=0.00) and 0.50 at nine months after surgery (p=0.00). No significant improvement in RNFL thickness was observed at three months or nine months after surgery. The mean score of mfVEP also improved significantly: 0.85 before surgery; 0.53 at three months (p=0.00) and 0.38 at nine months after surgery (P=0.00). No statistical difference was observed in the outcome of patients at nine months of follow-up and 18 months of follow-up. Visual field and mfVEP recovery with unchanged RNFL thickness was observed in patients after transsphenoid pituitary adenoma resection. Copyright © 2016. Published by Elsevier B.V.
Schrems, W A; Laemmer, R; Hoesl, L M; Horn, F K; Mardin, C Y; Kruse, F E; Tornow, R P
2011-10-01
To investigate the influence of atypical retardation pattern (ARP) on the distribution of peripapillary retinal nerve fibre layer (RNFL) thickness measured with scanning laser polarimetry in healthy individuals and to compare these results with RNFL thickness from spectral domain optical coherence tomography (OCT) in the same subjects. 120 healthy subjects were investigated in this study. All volunteers received detailed ophthalmological examination, GDx variable corneal compensation (VCC) and Spectralis-OCT. The subjects were divided into four subgroups according to their typical scan score (TSS): very typical with TSS=100, typical with 99 ≥ TSS ≥ 91, less typical with 90 ≥ TSS ≥ 81 and atypical with TSS ≤ 80. Deviations from very typical normal values were calculated for 32 sectors for each group. There was a systematic variation of the RNFL thickness deviation around the optic nerve head in the atypical group for the GDxVCC results. The highest percentage deviation of about 96% appeared temporal with decreasing deviation towards the superior and inferior sectors, and nasal sectors exhibited a deviation of 30%. Percentage deviations from very typical RNFL values decreased with increasing TSS. No systematic variation could be found if the RNFL thickness deviation between different TSS-groups was compared with the OCT results. The ARP has a major impact on the peripapillary RNFL distribution assessed by GDx VCC; thus, the TSS should be included in the standard printout.
Kim, Yong Woo; Lee, Eun Ji; Kim, Tae-Woo; Kim, Mijin; Kim, Hyunjoong
2014-07-01
To investigate whether the rate of retinal nerve fiber layer (RNFL) thinning differs according to the microstructure of β-zone parapapillary atrophy (PPA) as evaluated by spectral-domain (SD) optical coherence tomography (OCT) in primary open-angle glaucoma (POAG). Prospective, observational, comparative study. A total of 195 eyes with POAG that had been evaluated by serial SD-OCT RNFL thickness measurements for ≥ 2 years. On the basis of the extent of Bruch's membrane (BM) within the β-zone PPA (area without retinal pigment epithelium [RPE]), as shown in the infrared fundus images, PPA was divided into PPA+BM (PPA with intact BM) and PPA-BM (PPA devoid of BM). Eyes were categorized into group A (having PPA+BM only, n=64), group B (having both PPA+BM and PPA-BM, n=58), group C (having PPA-BM only, n=32), and group D (without β-zone PPA, n=41). The rate of progressive OCT RNFL thinning was determined by linear regression and compared between groups. Factors influencing the rate of RNFL thinning were evaluated, including age, sex, follow-up duration, history of filtering surgery, baseline RNFL thickness, baseline intraocular pressure (IOP), mean IOP and IOP fluctuation during follow-up, PPA types, baseline PPA width, PPA width increase, axial length (AXL), central corneal thickness, and visual field mean deviation (MD). Rate of thinning of OCT RNFL thicknesses over time. Patients in groups B and C were significantly younger and more myopic, and had a greater AXL, than those in groups A and D (all P<0.001). The rate of global RNFL thinning was significantly faster in group A (-1.66 ± 2.94 μm/year) than in the other groups (group B, -0.87 ± 1.28 μm/year; group C, 0.20 ± 1.86 μm/year; group D, -0.28 ± 1.74 μm/year; P = 0.001). Multivariate regression showed a significant association of shorter follow-up period (P = 0.016), greater baseline global RNFL thickness (P = 0.035), type of β-zone PPA (group A, P = 0.023), and greater baseline PPA+BM width (P = 0.034) with a faster rate of RNFL thinning. The rate of RNFL thinning differed according to the microstructure of β-zone PPA. It was faster for eyes with β-zone PPA with intact BM than for eyes without β-zone PPA or with β-zone PPA devoid of BM. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Şahin, Muhammed; Şahin, Alparslan; Kılınç, Faruk; Karaalp, Ümit; Yüksel, Harun; Özkurt, Zeynep Gürsel; Türkcü, Fatih Mehmet; Çaça, İhsan
2018-02-01
To compare the retina ganglion cell complex (GCC) layer and peripapillary nerve fibre layer thickness (pRNFL) in patients with prediabetes and healthy subjects analysed by spectral domain optical coherence tomography (SD-OCT). This cross-sectional and comparative study included prediabetic patients and healthy subjects. All participants underwent SD-OCT measurement of pRNFL thickness, and GCC thickness. A total of 30 eyes of the 30 patients with prediabetes and 30 eyes of 30 controls were included. The overall calculated pRNFL thicknesses were similar between the prediabetic and control subjects. The GCC thickness was significantly lower in all quadrants of the inner macula, and outer nasal quadrant in the prediabetes group when compared to the control group. Our study demonstrated that inner macular GCC thickness was significantly thinner in prediabetic subjects. As a result neurodegeneration may play role in the thinning of GCC.
Kim, Eun Kyoung; Park, Hae-Young Lopilly; Park, Chan Kee
2017-01-01
To evaluate the changes of retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses and compare structure-function relationships of 4 retinal layers using spectral-domain optical coherence tomography (SD-OCT) in macular region of glaucoma patients. In cross-sectional study, a total of 85 eyes with pre-perimetric to advanced glaucoma and 26 normal controls were enrolled. The glaucomatous eyes were subdivided into three groups according to the severity of visual field defect: a preperimetric glaucoma group, an early glaucoma group, and a moderate to advanced glaucoma group. RNFL, GCL, IPL, and GCIPL thicknesses were measured at the level of the macula by the Spectralis (Heidelberg Engineering, Heidelberg, Germany) SD-OCT with automated segmentation software. For functional evaluation, corresponding mean sensitivity (MS) values were measured using 24-2 standard automated perimetry (SAP). RNFL, GCL, IPL, and GCIPL thicknesses were significantly different among 4 groups (P < .001). Macular structure losses were positively correlated with the MS values of the 24-2 SAP for RNFL, GCL, IPL, and GCIPL (R = 0.553, 0.636, 0.648 and 0.646, respectively, P < .001). In regression analysis, IPL and GCIPL thicknesses showed stronger association with the corresponding MS values of 24-2 SAP compared with RNFL and GCL thicknesses (R2 = 0.420, P < .001 for IPL; R2 = 0.417, P< .001 for GCIPL thickness). Segmented IPL thickness was significantly associated with the degree of glaucoma. Segmental analysis of the inner retinal layer including the IPL in macular region may provide valuable information for evaluating glaucoma.
Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting.
Biberoğlu, Esra; Eraslan, Muhsin; Baltacıoğlu, Feyyaz; Midi, İpek
2017-08-01
The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome.
Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
Biberoğlu, Esra; Eraslan, Muhsin; Baltacıoğlu, Feyyaz; Midi, İpek
2017-01-01
Objectives: The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. Materials and Methods: This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). Results: There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). Conclusion: IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome. PMID:28845322
Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT.
Kim, Young Kook; Ha, Ahnul; Lee, Won June; Jeoung, Jin Wook; Park, Ki Ho
2017-12-01
To introduce the measurement method of optic disc cup surface depth using spectral-domain optical coherence tomography (SD-OCT) and then evaluate the rates of cup surface depression at 3 different stages of glaucoma. We retrospectively identified 52 eyes with preperimetric glaucoma, 56 with mild-or-moderate glaucoma and 50 with severe glaucoma and followed them for at least 48 months. Eyes were imaged using SD-OCT (Cirrus HD-OCT) at 12-month intervals. The mean cup surface depth was calculated using the following formula: Cup volume/(disc area×average cup-to-disc ratio)-200 μm. The rates of mean cup surface depression (μm/y) were significantly greater in mild-or-moderate glaucoma (-7.96±1.03) than in preperimetric (-3.11±0.61) and severe glaucoma (-0.70±0.12; all P<0.001). The percentile rates of mean cup surface depression (%/y) were significantly greater than those of average of retinal nerve fiber layer (RNFL) thinning (%/y) in preperimetric glaucoma (-1.64±0.12 vs. -1.11±0.07; P<0.001) and mild-or-moderate glaucoma (-4.20±0.33 vs. -3.14±0.19; P<0.001); and conversely, in severe glaucoma, mean cup surface depth changed slower than did average RNFL thickness (-0.64±0.06 vs. -0.75±0.08%/y; P<0.001). In early-to-moderate glaucoma, the cup surface depth changed faster than did the RNFL thickness. These results signify the possibility that SD-OCT-based estimation of cup surface depth might be useful for monitoring of glaucoma development and progression.
Ganglion cell loss in relation to visual disability in multiple sclerosis.
Walter, Scott D; Ishikawa, Hiroshi; Galetta, Kristin M; Sakai, Reiko E; Feller, Daniel J; Henderson, Sam B; Wilson, James A; Maguire, Maureen G; Galetta, Steven L; Frohman, Elliot; Calabresi, Peter A; Schuman, Joel S; Balcer, Laura J
2012-06-01
We used high-resolution spectral-domain optical coherence tomography (SD-OCT) with retinal segmentation to determine how ganglion cell loss relates to history of acute optic neuritis (ON), retinal nerve fiber layer (RNFL) thinning, visual function, and vision-related quality of life (QOL) in multiple sclerosis (MS). Cross-sectional study. A convenience sample of patients with MS (n = 122; 239 eyes) and disease-free controls (n = 31; 61 eyes). Among MS eyes, 87 had a history of ON before enrollment. The SD-OCT images were captured using Macular Cube (200×200 or 512×128) and ONH Cube 200×200 protocols. Retinal layer segmentation was performed using algorithms established for glaucoma studies. Thicknesses of the ganglion cell layer/inner plexiform layer (GCL+IPL), RNFL, outer plexiform/inner nuclear layers (OPL+INL), and outer nuclear/photoreceptor layers (ONL+PRL) were measured and compared in MS versus control eyes and MS ON versus non-ON eyes. The relation between changes in macular thickness and visual disability was also examined. The OCT measurements of GCL+IPL and RNFL thickness; high contrast visual acuity (VA); low-contrast letter acuity (LCLA) at 2.5% and 1.25% contrast; on the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) and 10-Item Neuro-Ophthalmic Supplement composite score. Macular RNFL and GCL+IPL were significantly decreased in MS versus control eyes (P<0.001 and P = 0.001) and in MS ON versus non-ON eyes (P<0.001 for both measures). Peripapillary RNFL, macular RNFL, GCL+IPL, and the combination of macular RNFL+GCL+IPL were significantly correlated with VA (P≤0.001), 2.5% LCLA (P<0.001), and 1.25% LCLA (P≤0.001). Among OCT measurements, reductions in GCL+IPL (P<0.001), macular RNFL (P = 0.006), and the combination (macular RNFL+GCL+IPL; P<0.001) were most strongly associated with lower (worse) NEI-VFQ-25 and 10-Item Supplement QOL scores; GCL+IPL thinning was significant even accounting for macular RNFL thickness (P = 0.03 for GCL+IPL, P = 0.39 for macular RNFL). We demonstrated that GCL+IPL thinning is most significantly correlated with both visual function and vision-specific QOL in MS, and may serve as a useful structural marker of disease. Our findings parallel those of magnetic resonance imaging studies that show gray matter disease is a marker of neurologic disability in MS. Proprietary or commercial disclosure may be found after the references. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Hasanov, Samir; Demirkilinc Biler, Elif; Acarer, Ahmet; Akkın, Cezmi; Colakoglu, Zafer; Uretmen, Onder
2018-05-09
To evaluate and follow-up of functional and morphological changes of the optic nerve and ocular structures prospectively in patients with early-stage Parkinson's disease. Nineteen patients with a diagnosis of early-stage Parkinson's disease and 19 age-matched healthy controls were included in the study. All participants were examined minimum three times at the intervals of at least 6 month following initial examination. Pattern visually evoked potentials (VEP), contrast sensitivity assessments at photopic conditions, color vision tests with Ishihara cards and full-field visual field tests were performed in addition to measurement of retinal nerve fiber layer (RNFL) thickness of four quadrants (top, bottom, nasal, temporal), central and mean macular thickness and macular volumes. Best corrected visual acuity was observed significantly lower in study group within all three examinations. Contrast sensitivity values of the patient group were significantly lower in all spatial frequencies. P100 wave latency of VEP was significantly longer, and amplitude was lower in patient group; however, significant deterioration was not observed during the follow-up. Although average peripapillary RNFL thickness was not significant between groups, RNFL thickness in the upper quadrant was thinner in the patient group. While there was no difference in terms of mean macular thickness and total macular volume values between the groups initially, a significant decrease occurred in the patient group during the follow-up. During the initial and follow-up process, a significant deterioration in visual field was observed in the patient group. Structural and functional disorders shown as electro-physiologically and morphologically exist in different parts of visual pathways in early-stage Parkinson's disease.
Vinuthinee-Naidu, Munisamy-Naidu; Zunaina, Embong; Azreen-Redzal, Anuar; Nyi-Nyi, Naing
2017-06-14
Uric acid is a final breakdown product of purine catabolism in humans. It's a potent antioxidant and can also act as a pro-oxidant that induces oxidative stress on the vascular endothelial cells, thus mediating progression of diabetic related diseases. Various epidemiological and experimental evidence suggest that uric acid has a role in the etiology of type 2 diabetes mellitus. We conducted a cross-sectional study to evaluate the correlation of retinal nerve fibre layer (RNFL) and macular thickness with serum uric acid in type 2 diabetic patients. A cross-sectional study was conducted in the Eye Clinic, Hospital Universiti Sains Malaysia, Kelantan between the period of August 2013 till July 2015 involving type 2 diabetes mellitus patients with no diabetic retinopathy and with non-proliferative diabetic retinopathy (NPDR). An evaluation for RNFL and macular thickness was measured using Spectralis Heidelberg optical coherence tomography. Six ml of venous blood was taken for the measurement of serum uric acid and glycosylated haemoglobin (HbA1 C ). A total of 180 diabetic patients were recruited (90 patients with no diabetic retinopathy and 90 patients with NPDR) into the study. The mean level of serum uric acid for both the groups was within normal range and there was no significance difference between the two groups. Based on gender, both male and female gender showed significantly higher level of mean serum uric acid in no diabetic retinopathy group (p = 0.004 respectively). The mean serum uric acid was significantly higher in patient with HbA1 C < 6.5% (p < 0.031). Patients with NPDR have thicker RNFL and macular thickness compared to patients with no diabetic retinopathy. However, only the RNFL thickness of the temporal quadrant and the macular thickness of the superior outer, inferior outer and temporal outer subfields were statistically significant (p = 0.038, p = 0.004, 0.033 and <0.001 respectively). There was poor correlation between RNFL and macular thickness with serum uric acid in both the groups. Serum uric acid showed a poor correlation with RNFL and macular thickness among type 2 diabetic patients.
Fan, Kenneth Chen; Tsikata, Edem; Khoueir, Ziad; Simavli, Huseyin; Guo, Rong; DeLuna, Regina; Pandit, Sumir; Que, Christian John; de Boer, Johannes F.; Chen, Teresa C.
2017-01-01
Purpose To compare the diagnostic capability of 3-dimensional (3D) neuroretinal rim parameters with existing 2-dimensional (2D) neuroretinal and retinal nerve fiber layer (RNFL) thickness rim parameters using spectral domain optical coherence tomography (SD-OCT) volume scans Materials and Methods Design Institutional prospective pilot study. Study population 65 subjects (35 open angle glaucoma patients, 30 normal patients). Observation procedures One eye of each subject was included. SD-OCT was used to obtain 2D retinal nerve fiber layer (RNFL) thickness values and five neuroretinal rim parameters [i.e. 3D minimum distance band (MDB) thickness, 3D Bruch’s membrane opening-minimum rim width (BMO-MRW), 3D rim volume, 2D rim area, and 2D rim thickness]. Main outcome measures Area under the receiver operating characteristic (AUROC) curve values, sensitivity, specificity. Results Comparing all 3D with all 2D parameters, 3D rim parameters (MDB, BMO-MRW, rim volume) generally had higher AUROC curve values (range 0.770–0.946) compared to 2D parameters (RNFL thickness, rim area, rim thickness; range 0.678–0.911). For global region analyses, all 3D rim parameters (BMO-MRW, rim volume, MDB) were equal to or better than 2D parameters (RNFL thickness, rim area, rim thickness; p-values from 0.023–1.0). Among the three 3D rim parameters (MDB, BMO-MRW, and rim volume), there were no significant differences in diagnostic capability (false discovery rate > 0.05 at 95% specificity). Conclusion 3D neuroretinal rim parameters (MDB, BMO-MRW, and rim volume) demonstrated better diagnostic capability for primary and secondary open angle glaucomas compared to 2D neuroretinal parameters (rim area, rim thickness). Compared to 2D RNFL thickness, 3D neuroretinal rim parameters have the same or better diagnostic capability. PMID:28234677
Amanullah, Sarah; Okudolo, Joseph; Rahmatnejad, Kamran; Lin, Shuai-Chun; Wizov, Sheryl S; Manzi Muhire, Remy S; Hark, Lisa A; Zheng, Cindy X; Zhan, Tingting; Spaeth, George L
2017-12-01
To evaluate the correlation between contrast sensitivity (CS) and retinal nerve fiber layer (RNFL) in different areas of vision. This report is a sub-analysis of a prospective, observational cohort study investigating changes in performance-based assessment, vision-related quality of life, and clinical measures in patients with moderate to advanced glaucoma. The study included 161 participants with at least a 2-year history of glaucoma who underwent annual testing for 4 years. Contrast sensitivity was measured using the Spaeth/Richman contrast sensitivity (SPARCS) test, while RNFL thickness (RNFLT) was measured using Cirrus optical coherence tomography (OCT). Statistical analyses were performed to determine correlations between CS and RNFLT; the correlations were calculated for each annual visit, totaling four correlation coefficients for each patient over the course of 4 years. The SPARCS score in the left upper area of vision correlated the most strongly with the RNFLT of the inferior quadrant for both eyes at each annual visit, specifically in the seven o'clock sector for the left eye and the six o'clock sector for the right eye (p < 0.05). There were no discernible trends for the correlations between the other areas of CS and RNFL quadrants or clock hours over the 4 years of the study. Linear regression between the SPARCS total score and average RNFLT showed a significant direct correlation at each visit (p < 0.01). Contrast sensitivity in the left upper area of vision for both eyes correlated most strongly with the thickness of the inferior quadrant of the RNFL. These fibers project to the temporal portion of the right occipital lobe, implying a potential center for contrast perception in this area. The longitudinal nature of the study suggests that CS may be a predictive tool for changes in RNFL in patients with glaucoma. Despite this finding, retinal damage and its relationship to CS was diffuse. In addition, SPARCS was shown to predict RNFLT. Further research is warranted to understand how CS can be used as a tool in the clinical setting.
The Comparison of Regional RNFL and Fundus Vasculature by OCTA in Chinese Myopia Population.
Li, Yuanjun; Miara, Hamza; Ouyang, Pingbo; Jiang, Bing
2018-01-01
To determine the correlations between peripapillary vessel density, retinal nerve fibre layer (RNFL) thickness, and myopic indices at retina quadrants with optical coherence tomography angiography (OCTA) in Chinese. Fifty-six subjects with a mean spherical equivalent (MSE) of -3.63 ± 0.29 D were included. Peripapillary RNFL thickness and retinal vessel density in four sectors (superior, nasal, inferior, and temporal quadrants) were determined by OCTA, and correlations of the main outcomes were analyzed. Negative correlations were found between the peripapillary RNFL thickness and axial length (AL) at superior ( r = -0.335, P = 0.001) and inferior ( r = -0.551, P < 0.001) quadrants. There was a significant positive correlation with spherical equivalent (SE) at the corresponding quadrants as well as at the nasal quadrant ( r = 0.339, P = 0.001; r = 0.379, P < 0.001; and r = 0.209, P = 0.039, resp.). Peripapillary retinal vessel density was also negatively correlated with AL at the nasal quadrant ( r = -0.392, P < 0.001), and only at the nasal quadrant, there was a positive correlation between the peripapillary vessel density and SE ( r = 0.319, P = 0.001). The degree of myopia and elongation of AL were negatively correlated with peripapillary RNFL thickness at superior and inferior quadrants and with peripapillary retinal vessel density at the nasal quadrant.
The Comparison of Regional RNFL and Fundus Vasculature by OCTA in Chinese Myopia Population
2018-01-01
Purpose To determine the correlations between peripapillary vessel density, retinal nerve fibre layer (RNFL) thickness, and myopic indices at retina quadrants with optical coherence tomography angiography (OCTA) in Chinese. Methods Fifty-six subjects with a mean spherical equivalent (MSE) of −3.63 ± 0.29 D were included. Peripapillary RNFL thickness and retinal vessel density in four sectors (superior, nasal, inferior, and temporal quadrants) were determined by OCTA, and correlations of the main outcomes were analyzed. Results Negative correlations were found between the peripapillary RNFL thickness and axial length (AL) at superior (r = −0.335, P = 0.001) and inferior (r = −0.551, P < 0.001) quadrants. There was a significant positive correlation with spherical equivalent (SE) at the corresponding quadrants as well as at the nasal quadrant (r = 0.339, P = 0.001; r = 0.379, P < 0.001; and r = 0.209, P = 0.039, resp.). Peripapillary retinal vessel density was also negatively correlated with AL at the nasal quadrant (r = −0.392, P < 0.001), and only at the nasal quadrant, there was a positive correlation between the peripapillary vessel density and SE (r = 0.319, P = 0.001). Conclusions The degree of myopia and elongation of AL were negatively correlated with peripapillary RNFL thickness at superior and inferior quadrants and with peripapillary retinal vessel density at the nasal quadrant. PMID:29651341
Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina
2005-01-01
The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.
Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography
Smith, Michael; Frost, Andrew; Graham, Christopher Mark; Shaw, Steven
2007-01-01
Aims To examine the effect of pupillary dilatation on the reliability of retinal nerve fibre layer (RNFL) and optic nerve head (ONH) assessments using Stratus OCT in a glaucoma clinic. Methods Observational study of 38 patients attending a glaucoma clinic. The “fast optic disc” and “fast RNFL thickness” programs on Stratus OCT were used to measure the RNFL thickness and ONH cup to disc ratio (CDR). Two scans were done before dilatation and two after dilatation with tropicamide 1% drops. The mean values and reproducibility before and after dilatation were compared, along with the quality of scans as indicated by the “signal strength” score. Results In nine patients (23.7%) no images were obtained undilated but after dilatation examination was possible in all patients. Inability to obtain an undilated scan was associated with smaller pupil size and increasing cataract. The scan quality, as judged by the signal strength score, was higher dilated than undilated for both RNFL thickness (p = 0.011) and ONH CDR (p = 0.007). Reproducibility was higher with dilated scans for RNFL thickness but not for ONH CDR. There were significant differences between the dilated and undilated examinations for three of the five RNFL thickness variables and two of the three ONH CDR categories. Conclusions Acquisition of high quality OCT images was not possible without pupillary dilatation in about 25% of the patients. The dilated scans were more reproducible and of higher quality than the undilated scans. The two methods of examination do not appear to be interchangeable, suggesting that in follow up examinations the pupil should be in the same condition as at baseline. Pupillary dilatation is recommended before glaucoma assessments using Stratus OCT. PMID:17556429
Tornow, Ralf P.; Odstrcilik, Jan; Mayer, Markus A.; Gazarek, Jiri; Jan, Jiri; Kubena, Tomas; Cernosek, Pavel
2013-01-01
The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects. PMID:24454526
Kolar, Radim; Tornow, Ralf P; Laemmer, Robert; Odstrcilik, Jan; Mayer, Markus A; Gazarek, Jiri; Jan, Jiri; Kubena, Tomas; Cernosek, Pavel
2013-01-01
The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.
Reduction in Retinal Nerve Fiber Layer Thickness in Young Adults with Autism Spectrum Disorders
ERIC Educational Resources Information Center
Emberti Gialloreti, Leonardo; Pardini, Matteo; Benassi, Francesca; Marciano, Sara; Amore, Mario; Mutolo, Maria Giulia; Porfirio, Maria Cristina; Curatolo, Paolo
2014-01-01
Recent years have seen an increase in the use of retinal nerve fiber layer (RNFL) evaluation as an easy-to-use, reproducible, proxy-measure of brain structural abnormalities. Here, we evaluated RNFL thickness in a group of subjects with high functioning autism (HFA) or with Asperger Syndrome (AS) to its potential as a tool to study autism…
Dagi, Linda R; Tiedemann, Laura M; Heidary, Gena; Robson, Caroline D; Hall, Amber M; Zurakowski, David
2014-12-01
Detecting and monitoring optic neuropathy in patients with craniosynostosis is a clinical challenge due to limited cooperation, and subjective measures of visual function. The purpose of this study was to appraise the correlation of peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral-domain ocular coherence tomography (SD-OCT) with indication of optic neuropathy based on fundus examination. The medical records of all patients with craniosynostosis presenting for ophthalmic evaluation during 2013 were retrospectively reviewed. The following data were abstracted from the record: diagnosis, historical evidence of elevated intracranial pressure, current ophthalmic evaluation and visual field results, and current peripapillary RNFL thickness. A total of 54 patients were included (mean age, 10.6 years [range, 2.4-33.8 years]). Thirteen (24%) had evidence of optic neuropathy based on current fundus examination. Of these, 10 (77%) demonstrated either peripapillary RNFL elevation and papilledema or depression with optic atrophy. Sensitivity for detecting optic atrophy was 88%; for papilledema, 60%; and for either form of optic neuropathy, 77%. Specificity was 94%, 90%, and 83%, respectively. Kappa agreement was substantial for optic atrophy (κ = 0.73) and moderate for papilledema (κ = 0.39) and for either form of optic neuropathy (κ = 0.54). Logistic regression indicated that peripapillary RNFL thickness was predictive of optic neuropathy (P < 0.001). Multivariable analysis demonstrated that RNFL thickness measurements were more sensitive at detecting optic neuropathy than visual field testing (likelihood ratio = 10.02; P = 0.002). Sensitivity and specificity of logMAR visual acuity in detecting optic neuropathy were 15% and 95%, respectively. Peripapillary RNFL thickness measured by SD-OCT provides adjunctive evidence for identifying optic neuropathy in patients with craniosynostosis and appears more sensitive at detecting optic atrophy than papilledema. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Duman, R; Yavas, G F; Veliyev, I; Dogan, M; Duman, R
2018-05-10
The aim was to assess the ganglion cell complex (GCC) thickness, retinal nerve fiber layer (RNFL) thickness and optic disk features in the affected eyes (AE) and unaffected fellow eyes (FE) of subjects with unilateral nonarteritic anterior ischemic optic neuropathy (NAION) and to compare with healthy control eyes (CE) using spectral domain-optical coherence tomography (SD-OCT). This study included 28 patients and age, sex and refraction-matched 28 control subjects. Mean GCC thickness and peripapillary RNFL thickness in four quadrants measured by cirrus SD-OCT were evaluated in both AE and FE of patients and CE. In addition, optic disk measurements obtained with OCT were evaluated. Mean GCC thickness was significantly lower in AE compared with both FE and CE (P < 0.001), and mean GCC thickness in FE was significantly lower than CE (P = 0.022). In addition, mean RNFL thickness in superior and nasal quadrants significantly decreased in FE compared with CE (P = 0.020 and 0.010, respectively). Furthermore, AE had significantly greater optic disk cupping compared with both FE and CE (P < 0.001). GCC and RNFL thickness decreased significantly at late stages of NAION, in both AE and FE compared with CE, suggesting that some subclinical structural changes may occur in FE despite lack of obvious visual symptoms. In addition, there was no significant difference in optic disk features between the CE and FE. And significantly greater optic disk cupping in the AE compared with both FE and CE supports the acquired enlargement of cupping after the onset of NAION.
Scanning laser polarimetry in glaucoma
Dada, Tanuj; Sharma, Reetika; Angmo, Dewang; Sinha, Gautam; Bhartiya, Shibal; Mishra, Sanjay K; Panda, Anita; Sihota, Ramanjit
2014-01-01
Glaucoma is an acquired progressive optic neuropathy which is characterized by changes in the optic nerve head and retinal nerve fiber layer (RNFL). White-on-white perimetry is the gold standard for the diagnosis of glaucoma. However, it can detect defects in the visual field only after the loss of as many as 40% of the ganglion cells. Hence, the measurement of RNFL thickness has come up. Optical coherence tomography and scanning laser polarimetry (SLP) are the techniques that utilize the evaluation of RNFL for the evaluation of glaucoma. SLP provides RNFL thickness measurements based upon the birefringence of the retinal ganglion cell axons. We have reviewed the published literature on the use of SLP in glaucoma. This review elucidates the technological principles, recent developments and the role of SLP in the diagnosis and monitoring of glaucomatous optic neuropathy, in the light of scientific evidence so far. PMID:25494244
Scanning laser polarimetry in glaucoma.
Dada, Tanuj; Sharma, Reetika; Angmo, Dewang; Sinha, Gautam; Bhartiya, Shibal; Mishra, Sanjay K; Panda, Anita; Sihota, Ramanjit
2014-11-01
Glaucoma is an acquired progressive optic neuropathy which is characterized by changes in the optic nerve head and retinal nerve fiber layer (RNFL). White-on-white perimetry is the gold standard for the diagnosis of glaucoma. However, it can detect defects in the visual field only after the loss of as many as 40% of the ganglion cells. Hence, the measurement of RNFL thickness has come up. Optical coherence tomography and scanning laser polarimetry (SLP) are the techniques that utilize the evaluation of RNFL for the evaluation of glaucoma. SLP provides RNFL thickness measurements based upon the birefringence of the retinal ganglion cell axons. We have reviewed the published literature on the use of SLP in glaucoma. This review elucidates the technological principles, recent developments and the role of SLP in the diagnosis and monitoring of glaucomatous optic neuropathy, in the light of scientific evidence so far.
Comparison of macular OCTs in right and left eyes of normal people
NASA Astrophysics Data System (ADS)
Mahmudi, Tahereh; Kafieh, Rahele; Rabbani, Hossein; Mehri dehnavi, Alireza; Akhlagi, Mohammadreza
2014-03-01
Retinal 3D Optical coherence tomography (OCT) is a non-invasive imaging modality in ocular diseases. Due to large volumes of OCT data, it is better to utilize automatic extraction of information from OCT images, such as total retinal thickness and retinal nerve fiber layer thickness (RNFLT). These two thickness values have become useful indices to indicate the progress of diseases like glaucoma, according to the asymmetry between two eyes of an individual. Furthermore, the loss of ganglion cells may not be diagnosable by other tests and even not be evaluated when we only consider the thickness of one eye (due to dramatic different thickness among individuals). This can justify our need to have a comparison between thicknesses of two eyes in symmetricity. Therefore, we have proposed an asymmetry analysis of the retinal nerve layer thickness and total retinal thickness around the macula in the normal Iranian population. In the first step retinal borders are segmented by diffusion map method and thickness profiles were made. Then we found the middle point of the macula by pattern matching scheme. RNFLT and retinal thickness are analyzed in 9 sectors and the mean and standard deviation of each sector in the right and left eye are obtained. The maximums of the average RNFL thickness in right and left eyes are seen in the perifoveal nasal, and the minimums are seen in the fovea. Tolerance limits in RNFL thickness is shown to be between 0.78 to 2.4 μm for 19 volunteers used in this study.
Horn, Folkert K; Tornow, Ralf P; Jünemann, Anselm G; Laemmer, Robert; Kremers, Jan
2014-04-11
We compared the results of flicker-defined form (FDF) perimetry with standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements using spectral domain optical coherence tomography (OCT). A total of 64 healthy subjects, 45 ocular hypertensive patients, and 97 "early" open-angle glaucoma (OAG) patients participated in this study. Definition of glaucoma was based exclusively on glaucomatous optic disc appearance. All subjects underwent FDF perimetry, SAP, and peripapillary measurements of the RNFL thickness. The FDF perimetry and SAP were performed at identical test locations (G1 protocol). Exclusion criteria were subjects younger than 34 years, SAP mean defect (SAP MD) > 5 dB, eye diseases other than glaucoma, or nonreliable FDF measurements. The correlations between the perimetric data on one hand and RNFL thicknesses on the other hand were analyzed statistically. The age-corrected sensitivity values and the local results from the controls were used to determine FDF mean defect (FDF MD). The FDF perimetry and SAP showed high concordance in this cohort of experienced patients (MD values, R = -0.69, P < 0.001). Of a total of 42 OAG patients with abnormal SAP MD, 38 also displayed abnormal FDF MD. However, FDF MD was abnormal in 28 of 55 OAG patients with normal SAP MD. The FDF MD was significantly (R = -0.61, P < 0.001) correlated with RNFL thickness with a (nonsignificantly) larger correlation coefficient than conventional SAP MD (R = -0.48, P < 0.001). The FDF perimetry is able to uncover functional changes concurrent with the changes in RNFL thickness. The FDF perimetry may be an efficient functional test to detect early glaucomatous nerve atrophy. (ClinicalTrials.gov number, NCT00494923.).
Horn, Folkert K; Kaltwasser, Christoph; Jünemann, Anselm G; Kremers, Jan; Tornow, Ralf P
2012-04-01
There is evidence that multifocal visual evoked potentials (VEPs) can be used as an objective tool to detect visual field loss. The aim of this study was to correlate multifocal VEP amplitudes with standard perimetry data and retinal nerve fibre layer (RNFL) thickness. Multifocal VEP recordings were performed with a four-channel electrode array using 58 stimulus fields (pattern reversal dartboard). For each field, the recording from the channel with maximal signal-to-noise ratio (SNR) was retained, resulting in an SNR optimised virtual recording. Correlation with RNFL thickness, measured with spectral domain optical coherence tomography and with standard perimetry, was performed for nerve fibre bundle related areas. The mean amplitudes in nerve fibre related areas were smaller in glaucoma patients than in normal subjects. The differences between both groups were most significant in mid-peripheral areas. Amplitudes in these areas were significantly correlated with corresponding RNFL thickness (Spearman R=0.76) and with standard perimetry (R=0.71). The multifocal VEP amplitude was correlated with perimetric visual field data and the RNFL thickness of the corresponding regions. This method of SNR optimisation is useful for extracting data from recordings and may be appropriate for objective assessment of visual function at different locations. This study has been registered at http://www.clinicaltrials.gov (NCT00494923).
Liu, G Y; Utset, T O; Bernard, J T
2015-10-01
Due to the lack of reliable biomarkers in diagnosing and monitoring neuropsychiatric systemic lupus erythematosus (NPSLE), the aim of this study was to examine the utility of measurements obtained through spectral domain optical coherence tomography (SD-OCT) as a biomarker for NP involvement in SLE. Retinal nerve fiber layer (RNFL) and macula scans were performed using SD-OCT on 15 NPSLE patients, 16 SLE patients without NP symptoms (non-NP SLE), and 16 healthy controls. Macular volume and thickness of the central macula and peripapillary RNFL were compared between the groups and to scores on two validated cognitive tests. NPSLE patients did not differ significantly from non-NP SLE patients in retinal thickness or macular volume. However, SLE patients as a whole showed significant RNFL and macular thinning compared to controls. Scores on the Trail Making Test B, a test of complex attention, showed significant correlation to temporal superior and temporal inferior RNFL thickness. Our results demonstrate RNFL thinning in SLE, and confirm the previous finding of high incidence of abnormal brain scans in SLE. These findings suggest that OCT measurements may be indicative of neurodegeneration in SLE and may be a useful biomarker for early cognitive impairment in SLE. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Kucukevcilioglu, Murat; Ayyildiz, Onder; Aykas, Seckin; Gokce, Gokcen; Koylu, Mehmet Talay; Ozgonul, Cem; Ozge, Gokhan; Mumcuoglu, Tarkan; Yumusak, Erhan
2017-02-01
To investigate retinal nerve fiber layer thickness (RNFL-T) and peripapillary choroidal thickness (PC-T) in non-glaucomatous optic atrophy (OA) patients in comparison with unaffected and control eyes, furthermore, to compare thickness profiles with unilateral pseudoexfoliative advanced glaucoma. Thirty-three eyes with OA (Group A), 33 unaffected fellow eyes (Group B), 25 right eyes of 25 control subjects (Group C), and 15 eyes with advanced glaucoma (Group D) were enrolled. RNFL-T was measured in six regions by spectral-domain optical coherence tomography. Enhanced depth imaging optical coherence tomography was obtained to evaluate PC-T in corresponding regions. RNFL-T was significantly lower in Group A than in Groups B and C globally and at all peripapillary regions (all p < 0.001). P-CT in Group A was significantly lower globally (p = 0.03) and in three regions (temporal, p = 0.001; temporal-superior, p = 0.01; and nasal-inferior, p = 0.037) versus Group C. However, it was significantly thinner than in Group B in all regions (temporal, p = 0.02; temporal-superior, p = 0.013; nasal-superior, p = 0.044; nasal, p = 0.02; nasal-inferior, p < 0.001; and temporal-inferior, p < 0.001) and globally (p < 0.001). In Group A RNFL-T (thicker superiorly and inferiorly; thinner temporally and nasally) and PC-T (superior > temporal > nasal > inferior) profiles were almost identical to that in unaffected fellow eyes and control eyes. However, Group D showed different patterns with less regional differences in RNFL-T, and the greatest value of PC-T in nasal quadrant. Besides retinal nerve fiber layer thinning, non-glaucomatous OA is associated with choroidal thinning. The RNFL-T and PC-T profiles in advanced glaucoma eyes differed from the common patterns seen among OA eyes, unaffected fellow eyes, and control eyes.
Sobacı, Güngör; Güngör, Rıza; Özge, Gökhan
2013-01-01
AIM To determine the effect of multiple injections of ranibizumab or bevacizumab on retinal nerve fiber layer (RNFL) and intraocular pressure (IOP) in patients with age-related macular degeneration (AMD). METHODS This retrospective study includes 35 eyes of 35 patients treated with intravitreal bevacizumab (IVB, 1.25mg/0.05mL) and 30 eyes of 30 patients with intravitreal ranibizumab (IVR, 0.5mg/0.05mL) who had Fast RNFL analysis (Stratus™); IOP measurements were taken 30 minutes and 24 hours after each injection. RESULTS The mean ages were 68.0±7.5 and 69.1±7.7 years in the IVR and IVB groups, respectively (P=0.55). They underwent (6.3±1.9) and (5.1±1.3) injections (P=0.07) over (13.6±2.1) and (14.05±2.6) months (P=0.45) in the IVR and IVB groups, respectively. Changes in overall and temporal RNFL thickness in IVR-treated eyes (105.3±6.9µm and 74.4±11.2µm) were not different from those in untreated eyes in the IVR group (104.6± 8.4µm and 75.1±12.6µm) (P=0.57 and P=0.41, respectively). Similarly, overall and temporal RNFL thickness in IVB-treated eyes (105.8±8.1µm and 74.5±11.8µm) were not different from those in untreated eyes in the IVB group (104.6±8µm and 74.8±12.9µm) (P=0.42 and P=0.80, respectively). The frequencies of IOP rise (P=0.60) and changes in RNFL thickness from baseline (P=0.16) were comparable between groups. CONCLUSION Repeated intravitreal injection of ranibizumab or bevacizumab does not seem have adverse effects on RNFL thickness or IOP in wet AMD patients. PMID:23638426
Sobacı, Güngör; Güngör, Rıza; Ozge, Gökhan
2013-01-01
To determine the effect of multiple injections of ranibizumab or bevacizumab on retinal nerve fiber layer (RNFL) and intraocular pressure (IOP) in patients with age-related macular degeneration (AMD). This retrospective study includes 35 eyes of 35 patients treated with intravitreal bevacizumab (IVB, 1.25mg/0.05mL) and 30 eyes of 30 patients with intravitreal ranibizumab (IVR, 0.5mg/0.05mL) who had Fast RNFL analysis (Stratus™); IOP measurements were taken 30 minutes and 24 hours after each injection. The mean ages were 68.0±7.5 and 69.1±7.7 years in the IVR and IVB groups, respectively (P=0.55). They underwent (6.3±1.9) and (5.1±1.3) injections (P=0.07) over (13.6±2.1) and (14.05±2.6) months (P=0.45) in the IVR and IVB groups, respectively. Changes in overall and temporal RNFL thickness in IVR-treated eyes (105.3±6.9µm and 74.4±11.2µm) were not different from those in untreated eyes in the IVR group (104.6± 8.4µm and 75.1±12.6µm) (P=0.57 and P=0.41, respectively). Similarly, overall and temporal RNFL thickness in IVB-treated eyes (105.8±8.1µm and 74.5±11.8µm) were not different from those in untreated eyes in the IVB group (104.6±8µm and 74.8±12.9µm) (P=0.42 and P=0.80, respectively). The frequencies of IOP rise (P=0.60) and changes in RNFL thickness from baseline (P=0.16) were comparable between groups. Repeated intravitreal injection of ranibizumab or bevacizumab does not seem have adverse effects on RNFL thickness or IOP in wet AMD patients.
Retinal tissue thickness in type 1 and type 2 diabetes.
Srinivasan, Sangeetha; Pritchard, Nicola; Sampson, Geoff P; Edwards, Katie; Vagenas, Dimitrios; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2016-01-01
The objective was to investigate full retinal and inner retinal thickness in individuals with type 1 and type 2 diabetes. Eighty-four individuals with type 1 diabetes (T1DM), 67 individuals with type 2 diabetes (T2DM) and 42 non-diabetic individuals (control group) were enrolled. Participants underwent full retinal thickness evaluation in the central retinal, parafoveal and perifoveal zones and in the retinal nerve fibre layer (RNFL) and ganglion cell complex (GCC), using spectral domain optical coherence tomography. As a preliminary step, the key variables of interest - age, sex, diabetic retinopathy (DR), duration of diabetes and HbA1c levels - were analysed and compared between the three groups. Full retinal thickness, RNFL and GCC thicknesses were also compared between the groups. The relationship between the type of diabetes and retinal tissue thickness was explored, adjusting for the five potential confounders. Compared to individuals with T1DM, individuals with T2DM had significantly reduced full retinal thickness in the parafovea and perifovea and reduced RNFL and GCC thickness. The mean differences were six (p = 0.020), seven (p = 0.008), six (p = 0.021) and four micrometres (p = 0.013) for the parafovea, perifovea, RNFL and GCC thicknesses, respectively. Thicknesses within the central zone (p = 0.018) and at the parafovea (p = 0.007) were significantly reduced in T2DM when compared to the control group. After adjusting for age, sex, diabetic retinopathy, duration of diabetes and HbA1c levels, the relationship between type of diabetes and retinal tissue thickness was not statistically significant (p > 0.056). Retinal tissue thickness is not significantly different between type 1 and type 2 diabetes, when adjusted for age, sex, diabetic retinopathy, duration of diabetes and HbA1c levels. © 2016 Optometry Australia.
Kalenderoglu, Aysun; Çelik, Mustafa; Sevgi-Karadag, Ayse; Egilmez, Oguzhan Bekir
2016-11-01
Previous research has consistently detected inflammation in the etiology of depression and neuroimaging studies have demonstrated gray matter abnormalities implying a neurodegenerative process in depression. The aim of this study was to compare ganglion cell layer (GCL), and inner plexiform layer (IPL) volumes and retinal nerve fiber layer (RNFL) thickness between first episode and recurrent major depressive disorder (MDD) patients and controls using optic coherence tomography (OCT) in order to detect findings supporting a degenerative process. Also choroid thicknesses of the same groups were compared to examine effects of inflammation on MDD. This study included 50 recurrent MDD patients, 50 first episode MDD patients and 50 controls. OCT measurements were performed by a spectral OCT device. GCL and IPL volumes and RNFL and choroid thicknesses were measured automatically by the device. GCL and IPL volumes were significantly smaller in recurrent depression patients than first episode patients and in all MDD patients than controls. Also there were significant negative correlations between their volumes and disease severity parameters such as Ham-D and CGI scores, and disease duration. RNFL thicknesses were also lower in recurrent MDD patients than first episode patients and all MDD patients than controls but statistical significance was achieved only for global RNFL and temporal superior RNFL. Mean choroid thickness was higher in MDD patients than controls and in first episode MDD patients than recurrent MDD patients. Cross-sectional design of our study limits conclusions about progressive degeneration during the course of MDD. Lack of a control neuroimaging method like magnetic resonance imaging makes it hard to draw firm conclusions from our results. OCT finding of decreased GCL and IPL volumes supports previous research suggesting degeneration in MDD. OCT may be an important tool to track neurodegeneration in patients with major depression. Considering RNFL to be the latest layer that will be affected during course of degeneration, GCL and IPL volumes appear to be better parameters to follow. In addition, choroid may be an important structure to detect acute attack period and to follow inflammatory process in MDD like in systemic inflammatory diseases. Copyright © 2016 Elsevier B.V. All rights reserved.
Guclu, Orkut; Guclu, Hande; Huseyin, Serhat; Korkmaz, Selcuk; Yuksel, Volkan; Canbaz, Suat; Pelitli Gurlu, Vuslat
2018-06-23
To examine changes in retinal ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (RNFL) thicknesses by optical coherence tomography (OCT) in contralateral and ipsilatateral eyes of carotid artery stenosis (CAS) patients before and after carotid endarterectomy (CEA). Forty-two consecutive patients diagnosed with CAS (70-99% stenosis rate) who underwent CEA were included in this prospective cross-sectional study. The indication for CEA was based on the Asymptomatic Carotid Atherosclerosis Study. Doppler ultrasonography and computed tomography angiography were performed to calculate CAS. All the subjects underwent an ophthalmological examination, including best corrected visual acuity (BCVA), intraocular pressure (IOP) measurements, biomicroscopy, fundoscopy, and OCT before and after the surgery. The mean preoperative intraocular pressure was 15.2 ± 2.1 mmHg in the ipsilateral eye and 15.8 ± 2.7 in the contralateral eye. The mean postoperative intraocular pressure in the ipsilateral and contralateral eye was 18.6 ± 3.0 and 19.3 ± 3.8, respectively. The intraocular pressure was significantly higher in postoperative eyes (p = 0.0001). There was a statistically significant decrease in peripapillary RNFL thickness in superior quadrants postoperatively in ipsilateral eyes. The retinal GCC layer thickness was not significantly different before and after CEA in ipsilateral and contralateral eyes. Carotid endarterectomy results in thinning of the superior peripapillary RNFL thickness. To the best of our knowledge, this is the first study to examine peripapillary RNFL and GCC thicknesses before and after CEA.
Alnawaiseh, Maged; Hömberg, Lisann; Eter, Nicole; Prokosch, Verena
2017-01-01
To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3-6) or the control group (group B: RNFL score 0-2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP.
Qiu, Kunliang; Wang, Geng; Lu, Xuehui; Zhang, Riping; Sun, Lixia; Zhang, Mingzhi
2018-03-01
We determined the applicability of inferior > superior > nasal > temporal (ISNT) rules on retinal nerve fibre layer (RNFL) thickness and rim area and evaluated the impact of various ocular factors on the performance of the ISNT rules in healthy myopic eyes. A total of 138 eyes from 138 healthy myopic subjects were included in this cross-sectional observational study. The peripapillary RNFL and optic disc in each eye were imaged with Cirrus HD optical coherence tomography (OCT) and Heidelberg Retina Tomograph II (HRT2), respectively. The performance of the inferior > superior (IS), inferior > superior > nasal > temporal (IST) and ISNT rules on RNFL thickness and rim area was determined and compared between low-to-moderate myopia and high myopia. The effects of ocular factors [including axial length, disc area, disc tilt, disc torsion, disc-fovea angle (DFA) and retina artery angle] on the performance of ISNT rules were evaluated with logistic regression analysis. The mean axial length and refractive error were 25.57 ± 1.09 mm (range, 22.52-28.77 mm) and -5.12 ± 2.30 D [range, -9.63 to -0.50 dioptres (D)], respectively. Sixty-three per cent of the healthy eyes were compliant with the ISNT rule on rim area, while ISNT rule on RNFL thickness was followed in only 11.6% of the included eyes. For rim area, smaller disc area was significantly associated with increased compliance of the IS rule (odds ratio: 0.46, p = 0.039), IST rule (odds ratio: 0.46, p = 0.037) and ISNT rule (odds ratio: 0.44, p = 0.030). For RNFL thickness, greater DFA was significantly associated with increased compliance of the IS and IST rules (odds ratio: 1.30, p < 0.001; odds ratio: 1.19, p = 0.006, respectively). In healthy myopic subjects, 88.4% and 37% of eyes did not comply with the ISNT rule on RNFL thickness and rim area, respectively. Due to significant low compliance in healthy eyes, the ISNT rule and its variants have limited potential utility in diagnosing glaucoma in myopic subjects. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Rates of retinal nerve fiber layer thinning in glaucoma suspect eyes
Miki, Atsuya; Medeiros, Felipe A.; Weinreb, Robert N.; Jain, Sonia; He, Feng; Sharpsten, Lucie; Khachatryan, Naira; Hammel, Na’ama; Liebmann, Jeffrey M.; Girkin, Christopher A.; Sample, Pamela A.; Zangwill, Linda M.
2015-01-01
Purpose To compare the rates of retinal nerve fiber layer (RNFL) loss in patients suspect of having glaucoma who developed visual field damage (VFD) to those who did not develop VFD, and to determine whether the rate of RNFL loss can be used to predict who will develop VFD.. Design Prospective observational cohort study Participants Glaucoma suspects, defined as having glaucomatous optic neuropathy or ocular hypertension (Intraocular pressure (IOP)>21 mmHg) without repeatable VFD at baseline from the Diagnostic Innovations in Glaucoma Study, and the African Descent and Glaucoma Evaluation Study. Methods Global and quadrant RNFL thickness (RNFLT) were measured with the Spectralis spectral-domain optical coherence tomography (SD-OCT). VFD was defined as having 3 consecutive abnormal visual fields. The rate of RNFL loss in eyes developing VFD was compared with eyes not developing VFD using multivariable linear mixed-effects models. A joint longitudinal survival model utilized the estimated RNFLT slope to predict the risk of developing VFD, while adjusting for potential confounding variables. Main Outcome Measures The rate of RNFL thinning and the probability of developing VFD. Results Four hundred and fifty-four eyes of 294 glaucoma suspects were included. The average number of SD-OCT examinations was 4.6 (range, 2–9) with median follow-up time of 2.2 (0.4–4.1) years. Forty eyes (8.8%) developed VFD. The estimated mean rate of global RNFL loss was significantly faster in eyes developing VFD compared with eyes that did not (−2.02μm/year vs. −0.82μm/year, P<0.001). The joint longitudinal survival model showed that each 1μm/year faster rate of global RNFL loss corresponded to a 2.05 times higher risk of developing VFD (Hazards Ratio (HR)=2.05, 95% Confidence Interval (CI): 1.14–3.71; p=0.017). Conclusions The rate of global RNFL loss was more than twice as fast in eyes developing VFD compared with eyes that did not develop them. Joint longitudinal survival model showed that a 1μm/year faster rate of RNFLT loss corresponded to a 2.05 times higher risk of developing VFD. These results suggest that measuring the rate of SD-OCT RNFL loss may be a useful tool to help identify patients who are at a high risk of developing visual field loss. PMID:24629619
Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K W; Yoshimura, Nagahisa
2016-01-01
To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction.
Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K. W.; Yoshimura, Nagahisa
2016-01-01
Purpose To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. Methods The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Results Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. Conclusions The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction. PMID:26814541
Moon, Byung Gil; Cho, Jung Woo; Kang, Sung Yong; Yun, Sung-Cheol; Na, Jung Hwa; Lee, Youngrok; Kook, Michael S.
2012-01-01
Purpose To evaluate the use of scanning laser polarimetry (SLP, GDx VCC) to measure the retinal nerve fiber layer (RNFL) thickness in order to evaluate the progression of glaucoma. Methods Test-retest measurement variability was determined in 47 glaucomatous eyes. One eye each from 152 glaucomatous patients with at least 4 years of follow-up was enrolled. Visual field (VF) loss progression was determined by both event analysis (EA, Humphrey guided progression analysis) and trend analysis (TA, linear regression analysis of the visual field index). SLP progression was defined as a reduction of RNFL exceeding the predetermined repeatability coefficient in three consecutive exams, as compared to the baseline measure (EA). The slope of RNFL thickness change over time was determined by linear regression analysis (TA). Results Twenty-two eyes (14.5%) progressed according to the VF EA, 16 (10.5%) by VF TA, 37 (24.3%) by SLP EA and 19 (12.5%) by SLP TA. Agreement between VF and SLP progression was poor in both EA and TA (VF EA vs. SLP EA, k = 0.110; VF TA vs. SLP TA, k = 0.129). The mean (±standard deviation) progression rate of RNFL thickness as measured by SLP TA did not significantly differ between VF EA progressors and non-progressors (-0.224 ± 0.148 µm/yr vs. -0.218 ± 0.151 µm/yr, p = 0.874). SLP TA and EA showed similar levels of sensitivity when VF progression was considered as the reference standard. Conclusions RNFL thickness as measurement by SLP was shown to be capable of detecting glaucoma progression. Both EA and TA of SLP showed poor agreement with VF outcomes in detecting glaucoma progression. PMID:22670073
Moon, Byung Gil; Sung, Kyung Rim; Cho, Jung Woo; Kang, Sung Yong; Yun, Sung-Cheol; Na, Jung Hwa; Lee, Youngrok; Kook, Michael S
2012-06-01
To evaluate the use of scanning laser polarimetry (SLP, GDx VCC) to measure the retinal nerve fiber layer (RNFL) thickness in order to evaluate the progression of glaucoma. Test-retest measurement variability was determined in 47 glaucomatous eyes. One eye each from 152 glaucomatous patients with at least 4 years of follow-up was enrolled. Visual field (VF) loss progression was determined by both event analysis (EA, Humphrey guided progression analysis) and trend analysis (TA, linear regression analysis of the visual field index). SLP progression was defined as a reduction of RNFL exceeding the predetermined repeatability coefficient in three consecutive exams, as compared to the baseline measure (EA). The slope of RNFL thickness change over time was determined by linear regression analysis (TA). Twenty-two eyes (14.5%) progressed according to the VF EA, 16 (10.5%) by VF TA, 37 (24.3%) by SLP EA and 19 (12.5%) by SLP TA. Agreement between VF and SLP progression was poor in both EA and TA (VF EA vs. SLP EA, k = 0.110; VF TA vs. SLP TA, k = 0.129). The mean (±standard deviation) progression rate of RNFL thickness as measured by SLP TA did not significantly differ between VF EA progressors and non-progressors (-0.224 ± 0.148 µm/yr vs. -0.218 ± 0.151 µm/yr, p = 0.874). SLP TA and EA showed similar levels of sensitivity when VF progression was considered as the reference standard. RNFL thickness as measurement by SLP was shown to be capable of detecting glaucoma progression. Both EA and TA of SLP showed poor agreement with VF outcomes in detecting glaucoma progression.
Hood, Donald C; Chen, Monica F; Lee, Dongwon; Epstein, Benjamin; Alhadeff, Paula; Rosen, Richard B; Ritch, Robert; Dubra, Alfredo; Chui, Toco Y P
2015-04-01
To improve our understanding of glaucomatous damage as seen on circumpapillary disc scans obtained with frequency-domain optical coherence tomography (fdOCT), fdOCT scans were compared to images of the peripapillary retinal nerve fiber (RNF) bundles obtained with an adaptive optics-scanning light ophthalmoscope (AO-SLO). The AO-SLO images and fdOCT scans were obtained on 6 eyes of 6 patients with deep arcuate defects (5 points ≤-15 db) on 10-2 visual fields. The AO-SLO images were montaged and aligned with the fdOCT images to compare the RNF bundles seen with AO-SLO to the RNF layer thickness measured with fdOCT. All 6 eyes had an abnormally thin (1% confidence limit) RNF layer (RNFL) on fdOCT and abnormal (hyporeflective) regions of RNF bundles on AO-SLO in corresponding regions. However, regions of abnormal, but equal, RNFL thickness on fdOCT scans varied in appearance on AO-SLO images. These regions could be largely devoid of RNF bundles (5 eyes), have abnormal-appearing bundles of lower contrast (6 eyes), or have isolated areas with a few relatively normal-appearing bundles (2 eyes). There also were local variations in reflectivity of the fdOCT RNFL that corresponded to the variations in AO-SLO RNF bundle appearance. Relatively similar 10-2 defects with similar fdOCT RNFL thickness profiles can have very different degrees of RNF bundle damage as seen on fdOCT and AO-SLO. While the results point to limitations of fdOCT RNFL thickness as typically analyzed, they also illustrate the potential for improving fdOCT by attending to variations in local intensity.
Gür Güngör, Sirel; Akman, Ahmet; Sarıgül Sezenöz, Almila; Tanrıaşıkı, Gülşah
2016-12-01
The presence of retinal nerve fiber layer (RNFL) split bundles was recently described in normal eyes scanned using scanning laser polarimetry and by histologic studies. Split bundles may resemble RNFL loss in healthy eyes. The aim of our study was to determine the prevalence of nerve fiber layer split bundles in healthy people. We imaged 718 eyes of 359 healthy persons with the spectral domain optical coherence tomography in this cross-sectional study. All eyes had intraocular pressure of 21 mmHg or less, normal appearance of the optic nerve head, and normal visual fields (Humphrey Field Analyzer 24-2 full threshold program). In our study, a bundle was defined as 'split' when there is localized defect not resembling a wedge defect in the RNFL deviation map with a symmetrically divided RNFL appearance on the RNFL thickness map. The classification was performed by two independent observers who used an identical set of reference examples to standardize the classification. Inter-observer consensus was reached in all cases. Bilateral superior split bundles were seen in 19 cases (5.29%) and unilateral superior split was observed in 15 cases (4.16%). In 325 cases (90.52%) there was no split bundle. Split nerve fiber layer bundles, in contrast to single nerve fiber layer bundles, are not common findings in healthy eyes. In eyes with normal optic disc appearance, especially when a superior RNFL defect is observed in RNFL deviation map, the RNLF thickness map and graphs should also be examined for split nerve fiber layer bundles.
Macular Thickness Assessment in Patients with Glaucoma and Its Correlation with Visual Fields
Vaz, Fernando T; Ramalho, Mário; Pedrosa, Catarina; Lisboa, Maria; Kaku, Paulo; Esperancinha, Florindo
2016-01-01
Aim To determine the relationship between macular thickness (MT) and visual field (VF) parameters, as well as with changes in the retinal nerve fiber layer (RNFL) thickness in patients with glaucoma and ocular hypertension (OH). Materials and methods Cross-sectional statistical analysis of spectral domain optical coherence tomography (SD-OCT) compared with several VF parameters (mean defect - MD and loss variance - LV), in a nonrandom sample of 70 eyes from patients with glaucoma or OH. Statistical analysis was performed using Statistical Package for Social Sciences®. The correlation coefficient used was determined by Spearman correlation and the value of p < 0.05 was considered statistically significant. Results A significant correlation was seen between VF parameters and decrease in MT (MD: r = –0.363, p = 0.002; LV: r=–0.378, p = 0.001). The results were more significant when we compared the LV in the group with average MT 270 to 300 μm (r = –0.413, p = 0.015). Asymmetry between the superior macula and inferior macula correlated with LV (r = 0.432, p = 0.019) in the group with MT < 270 μm. There was also a significant correlation between thinning of superior-temporal and inferior-temporal RNFL and the decrease of the superior and inferior MT respectively (p < 0.001). Conclusion Spectral domain optical coherence tomography measurements of retinal thickness in the macula correlate with VF parameters and RNFL parameters in glaucoma patients. This relationship was first demonstrated with static computerized perimetry made with Octopus 101®. These results can be a valuable aid for evaluating and monitoring of glaucoma patients, establishing a correlation between structure and function. Measurements of retinal thickness in the macula may be an additional instrument for early detection of structural changes and its correlation with functional defects. How to cite this article Mota M, Vaz FT, Ramalho M, Pedrosa C, Lisboa M, Kaku P, Esperancinha F. Macular Thickness Assessment in Patients with Glaucoma and Its Correlation with Visual Fields. J Curr Glaucoma Pract 2016;10(3):85-90. PMID:27857487
Tatham, Andrew J; Boer, Erwin R; Rosen, Peter N; Della Penna, Mauro; Meira-Freitas, Daniel; Weinreb, Robert N; Zangwill, Linda M; Medeiros, Felipe A
2014-11-01
To examine the relationship between glaucomatous structural damage and ability to divide attention during simulated driving. Cross-sectional observational study. Hamilton Glaucoma Center, University of California San Diego. Total of 158 subjects from the Diagnostic Innovations in Glaucoma Study, including 82 with glaucoma and 76 similarly aged controls. Ability to divide attention was investigated by measuring reaction times to peripheral stimuli (at low, medium, or high contrast) while concomitantly performing a central driving task (car following or curve negotiation). All subjects had standard automated perimetry (SAP) and optical coherence tomography was used to measure retinal nerve fiber layer (RNFL) thickness. Cognitive ability was assessed using the Montreal Cognitive Assessment and subjects completed a driving history questionnaire. Reaction times to the driving simulator divided attention task. The mean reaction times to the low-contrast stimulus were 1.05 s and 0.64 s in glaucoma and controls, respectively, during curve negotiation (P < .001), and 1.19 s and 0.77 s (P = .025), respectively, during car following. There was a nonlinear relationship between reaction times and RNFL thickness in the better eye. RNFL thickness remained significantly associated with reaction times even after adjusting for age, SAP mean deviation in the better eye, cognitive ability, and central driving task performance. Although worse SAP sensitivity was associated with worse ability to divide attention, RNFL thickness measurements provided additional information. Information from structural tests may improve our ability to determine which patients are likely to have problems performing daily activities, such as driving. Copyright © 2014 Elsevier Inc. All rights reserved.
Electrophysiology and optical coherence tomography to evaluate Parkinson disease severity.
Garcia-Martin, Elena; Rodriguez-Mena, Diego; Satue, Maria; Almarcegui, Carmen; Dolz, Isabel; Alarcia, Raquel; Seral, Maria; Polo, Vicente; Larrosa, Jose M; Pablo, Luis E
2014-02-04
To evaluate correlations between visual evoked potentials (VEP), pattern electroretinogram (PERG), and macular and retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) and the severity of Parkinson disease (PD). Forty-six PD patients and 33 age and sex-matched healthy controls were enrolled, and underwent VEP, PERG, and OCT measurements of macular and RNFL thicknesses, and evaluation of PD severity using the Hoehn and Yahr scale to measure PD symptom progression, the Schwab and England Activities of Daily Living Scale (SE-ADL) to evaluate patient quality of life (QOL), and disease duration. Logistical regression was performed to analyze which measures, if any, could predict PD symptom progression or effect on QOL. Visual functional parameters (best corrected visual acuity, mean deviation of visual field, PERG positive (P) component at 50 ms -P50- and negative (N) component at 95 ms -N95- component amplitude, and PERG P50 component latency) and structural parameters (OCT measurements of RNFL and retinal thickness) were decreased in PD patients compared with healthy controls. OCT measurements were significantly negatively correlated with the Hoehn and Yahr scale, and significantly positively correlated with the SE-ADL scale. Based on logistical regression analysis, fovea thickness provided by OCT equipment predicted PD severity, and QOL and amplitude of the PERG N95 component predicted a lower SE-ADL score. Patients with greater damage in the RNFL tend to have lower QOL and more severe PD symptoms. Foveal thicknesses and the PERG N95 component provide good biomarkers for predicting QOL and disease severity.
Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening
Sobacı, Güngör; Özge, Gökhan; Gündoğan, Fatih Ç
2012-01-01
Purpose To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Methods Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port® system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Results Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = −0.55, P = 0.004, r = 0.68, P = 0.001, r = −0.65, P = 0.001, and r = −0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Conclusion Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system. PMID:22536039
Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening.
Sobacı, Güngör; Ozge, Gökhan; Gündoğan, Fatih Ç
2012-01-01
To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port(®) system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = -0.55, P = 0.004, r = 0.68, P = 0.001, r = -0.65, P = 0.001, and r = -0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system.
Retina and Nerve Fiber Layer Thickness in Eyes with Thyroid-Associated Ophthalmopathy.
Blum Meirovitch, Sharon; Leibovitch, Igal; Kesler, Anat; Varssano, David; Rosenblatt, Amir; Neudorfer, Meira
2017-05-01
Thyroid-associated ophthalmopathy (TAO) is an inflammatory disease that affects the thyroid gland and the eye orbit. Of patients with TAO, 3%-5% have severe sight-threatening disease due to optic neuropathy Optical coherence tomography (OCT), the non-invasive imaging technology that yields high-resolution cross-sectional images of the retina, provides qualitative and quantitative data on the retina. To apply this technique to quantitatively assess retinal nerve fiber layer (RNFL) and macular ring thicknesses in healthy subjects and in patients with TAO to determine their relationship to the severity of the orbital disease. All patients in the ophthalmology clinic who were diagnosed with TAO and underwent OCT imaging as part of their ocular examination comprised the study group, and healthy patients who volunteered to undergo OCT examination served as controls. Results of the complete ophthalmologic examination and OCT findings were collected from medical files, including the thickness of the RNFL and the macula. The study comprised 21 patients and 41 healthy controls. TAO patients exhibited RNFL thickening and inner macula thinning compared to healthy subjects. Mean RNFL thickness was correlated with the severity of the orbital disease. The OCT findings suggest that the retina is involved in TAO, probably as early as the subclinical stage. This highlights the ability of OCT to identify retinal changes earlier and far more accurately than is detected today, enabling earlier diagnosis and more timely treatment to prevent severe visual sequelae.
Hömberg, Lisann; Eter, Nicole
2017-01-01
Purpose To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). Materials and Methods 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3–6) or the control group (group B: RNFL score 0–2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Results Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. Conclusions In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP. PMID:29119021
Grewal, Dilraj S.; Sehi, Mitra; Cook, Richard J.
2011-01-01
Purpose. To examine the impact of retardance pattern variability on retinal nerve fiber layer (RNFL) measurements over time using scanning laser polarimetry with variable (GDxVCC) and enhanced corneal compensation (GDxECC; both by Carl Zeiss Meditec, Inc., Dublin, CA). Methods. Glaucoma suspect and glaucomatous eyes with 4 years of follow-up participating in the Advanced Imaging in Glaucoma Study were prospectively enrolled. All eyes underwent standard automated perimetry (SAP), GDxVCC, and GDxECC imaging every 6 months. SAP progression was determined with point-wise linear regression analysis of SAP sensitivity values. Typical scan score (TSS) values were extracted as a measure of retardance image quality; an atypical retardation pattern (ARP) was defined as TSS < 80. TSS fluctuation over time was measured using three parameters: change in TSS from baseline, absolute difference (maximum minus minimum TSS value), and TSS variance. Linear mixed-effects models that accommodated the association between the two eyes were constructed to evaluate the relationship between change in TSS and RNFL thickness over time. Results. Eighty-six eyes (51 suspected glaucoma, 35 glaucomatous) of 45 patients were enrolled. Twenty (23.3%) eyes demonstrated SAP progression. There was significantly greater fluctuation in TSS over time with GDxVCC compared with GDxECC as measured by absolute difference (18.40 ± 15.35 units vs. 2.50 ± 4.69 units; P < 0.001), TSS variance (59.63 ± 87.27 units vs. 3.82 ± 9.63 units, P < 0.001), and change in TSS from baseline (−0.83 ± 11.2 vs. 0.25 ± 2.9, P = 0.01). The change in TSS over time significantly (P = 0.006) influenced the TSNIT average RNFL thickness when measured by GDxVCC but not by GDxECC. Conclusions. Longitudinal images obtained with GDxECC have significantly less variability in TSS and retardance patterns and have reduced bias produced by ARP on RNFL progression assessment. PMID:21296821
Rao, Harsha L; Kadambi, Sujatha V; Weinreb, Robert N; Puttaiah, Narendra K; Pradhan, Zia S; Rao, Dhanaraj A S; Kumar, Rajesh S; Webers, Carroll A B; Shetty, Rohit
2017-08-01
To evaluate the diagnostic ability of peripapillary vessel density measurements on optical coherence tomography angiography (OCTA) in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), and to compare these with peripapillary retinal nerve fibre layer (RNFL) thickness measurements. In a cross-sectional study, 48 eyes of 33 healthy control subjects, 63 eyes of 39 patients with POAG and 49 eyes of 32 patients with PACG underwent OCTA (RTVue-XR, Optovue, Fremont, California, USA) and RNFL imaging with spectral domain OCT. Diagnostic abilities of vessel density and RNFL parameters were evaluated using area under receiver operating characteristic curves (AUC) and sensitivities at fixed specificities. AUCs of peripapillary vessel density ranged between 0.48 for the temporal sector and 0.88 for the inferotemporal sector in POAG. The same in PACG ranged between 0.57 and 0.86. Sensitivities at 95% specificity ranged from 13% to 70% in POAG, and from 10% to 67% in PACG. AUCs of peripapillary RNFL thickness ranged between 0.51 for the temporal sector and 0.91 for the inferonasal sector in POAG. The same in PACG ranged between 0.61 and 0.87. Sensitivities at 95% specificity ranged from 8% to 68% in POAG, and from 2% to 67% in PACG. AUCs of all peripapillary vessel density measurements were comparable (p>0.05) to the corresponding RNFL thickness measurements in both POAG and PACG. Diagnostic ability of peripapillary vessel density parameters of OCTA, especially the inferotemporal sector measurement, was good in POAG and PACG. Diagnostic abilities of vessel density measurements were comparable to RNFL measurements in both POAG and PACG. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Fu, Lanxing; Aspinall, Peter; Bennett, Gary; Magidson, Jay; Tatham, Andrew J
2017-04-01
To quantify the influence of spectral domain optical coherence tomography (SDOCT) on decision-making in patients with suspected glaucoma. A prospective cross-sectional study involving 40 eyes of 20 patients referred by community optometrists due to suspected glaucoma. All patients had disc photographs and standard automated perimetry (SAP), and results were presented to 13 ophthalmologists who estimated pre-test probability of glaucoma (0-100%) for a total of 520 observations. Ophthalmologists were then permitted to modify probabilities of disease based on SDOCT retinal nerve fiber layer (RNFL) measurements (post-test probability). The effect of information from SDOCT on decision to treat, monitor, or discharge was assessed. Agreement among graders was assessed using intraclass correlation coefficients (ICC) and correlated component regression (CCR) was used to identify variables influencing management decisions. Patients had an average age of 69.0 ± 10.1 years, SAP mean deviation of 2.71 ± 3.13 dB, and RNFL thickness of 86.2 ± 16.7 μm. Average pre-test probability of glaucoma was 37.0 ± 33.6% with SDOCT resulting in a 13.3 ± 18.1% change in estimated probability. Incorporating information from SDOCT improved agreement regarding probability of glaucoma (ICC = 0.50 (95% CI 0.38 to 0.64) without SDOCT versus 0.64 (95% CI 0.52 to 0.76) with SDOCT). SDOCT led to a change from decision to "treat or monitor" to "discharge" in 22 of 520 cases and a change from "discharge" to "treat or monitor" in 11 of 520 cases. Pre-test probability and RNFL thickness were predictors of post-test probability of glaucoma, contributing 69 and 31% of the variance in post-test probability, respectively. Information from SDOCT altered estimated probability of glaucoma and improved agreement among clinicians in those suspected of having the disease.
Srivastav, Khushboo; Mahdi, Abbas A.; Shukla, Rajendra K.; Meyer, Carsten H.; Akduman, Levent; Khanna, Vinay K.
2016-01-01
Purpose To study the correlation between serum levels of vitamin B12, folic acid, and homocysteine and the severity of diabetic retinopathy and the correlation with retinal nerve fiber layer (RNFL) thinning on spectral domain optical coherence tomography (SD-OCT). Methods In a tertiary care center–based prospective cross-sectional study, 60 consecutive cases and 20 healthy controls in the age group of 40–65 years were included. The eyes of the cases were divided into three groups according to Early Treatment Diabetic Retinopathy Study (ETDRS) classification: diabetes mellitus without retinopathy (n = 20), non-proliferative diabetic retinopathy with macular edema (n = 20), and proliferative diabetic retinopathy with macular edema (n = 20). The serum levels of vitamin B12 and folic acid were measured using a standard protocol. The serum homocysteine assay was performed using an enzyme-linked immunosorbent assay (ELISA) kit. Average RNFL thickness was measured using SD-OCT. Statistical analysis was used to assess the correlations between the study variables. Results Increased severity of diabetic retinopathy was found to correlate with an increase in the serum levels of homocysteine (F = 53.79; p<0.001). The mean serum levels of vitamin B12 and folic acid were found to be within the normal reference range. A positive correlation was found between retinal nerve fiber layer thinning and serum levels of homocysteine (p<0.001). Conclusions This study, for the first time, demonstrated a correlation between increased homocysteine with a decrease in RNFL thickness and increased severity of diabetic retinopathy. PMID:27994434
Diagnostic Capability of Peripapillary Retinal Thickness in Glaucoma Using 3D Volume Scans
Simavli, Huseyin; Que, Christian John; Akduman, Mustafa; Rizzo, Jennifer L.; Tsikata, Edem; de Boer, Johannes F.; Chen, Teresa C.
2015-01-01
Purpose To determine the diagnostic capability of spectral domain optical coherence tomography (SD-OCT) peripapillary retinal thickness (RT) measurements from 3-dimensional (3D) volume scans for primary open angle glaucoma (POAG). Design Cross-sectional study. Methods Setting Institutional Study population 156 patients (89 POAG and 67 normal subjects) Observation procedures One eye of each subject was included. SD-OCT peripapillary RT values from 3D volume scans were calculated for four quadrants of three different sized annuli. Peripapillary retinal nerve fiber layer (RNFL) thickness values were also determined. Main outcome measures Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. Results The top five RT AUROCs for all glaucoma patients and for a subset of early glaucoma patients were for the inferior quadrant of outer circumpapillary annulus of circular grid (OCA) 1 (0.959, 0.939), inferior quadrant of OCA2 (0.945, 0.921), superior quadrant of OCA1 (0.890, 0.811), inferior quadrant of OCA3 (0.887, 0.854), and superior quadrant of OCA2 (0.879, 0.807). Smaller RT annuli OCA1 and OCA2 consistently showed better diagnostic performance than the larger RT annulus OCA3. For both RNFL and RT measurements, best AUROC values were found for inferior RT OCA1 and OCA2, followed by inferior and overall RNFL thickness. Conclusion Peripapillary RT measurements from 3D volume scans showed excellent diagnostic performance for detecting both glaucoma and early glaucoma patients. Peripapillary RT values have the same or better diagnostic capability compared to peripapillary RNFL thickness measurements, while also having fewer algorithm errors. PMID:25498354
Tatham, Andrew J.; Boer, Erwin R.; Rosen, Peter N.; Penna, Mauro Della; Meira-Freitas, Daniel; Weinreb, Robert N.; Zangwill, Linda M.; Medeiros, Felipe A.
2014-01-01
Purpose To examine the relationship between glaucomatous structural damage and ability to divide attention during simulated driving. Design Cross-sectional observational study. Methods Setting Hamilton Glaucoma Center, University of California San Diego. Patient Population 158 subjects from the Diagnostic Innovations in Glaucoma Study, including 82 with glaucoma and 76 similarly aged controls. Observation Procedure Ability to divide attention was investigated by measuring reaction times to peripheral stimuli (at low, medium or high contrast) while concomitantly performing a central driving task (car following or curve negotiation). All subjects had standard automated perimetry (SAP) and optical coherence tomography was used to measured retinal nerve fiber (RNFL) thickness. Cognitive ability was assessed using the Montreal Cognitive Assessment and subjects completed a driving history questionnaire. Main outcome measures Reaction times to the driving simulator divided attention task. Results The mean reaction times to the low contrast stimulus were 1.05 s and 0.64 s in glaucoma and controls respectively during curve negotiation (P <0.001), and 1.19 s and 0.77 s (P = 0.025) respectively during car following. There was a non-linear relationship between reaction times and RNFL thickness in the better eye. RNFL thickness remained significantly associated with reaction times even after adjusting for age, SAP mean deviation in the better eye, cognitive ability and central driving task performance. Conclusions Although worse SAP sensitivity was associated with worse ability to divide attention, RNFL thickness measurements provided additional information. Information from structural tests may improve our ability to determine which patients are likely to have problems performing daily activities, such as driving. PMID:25068641
Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.
2016-01-01
Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P < 0.001; and wiVD: 46.2 ± 6%, 51.3 ± 5%, and 56.6 ± 3%, respectively; P < 0.001). For differentiating between glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505
Bae, Hyoung Won; Ji, Yongwoo; Lee, Hye Sun; Lee, Naeun; Hong, Samin; Seong, Gong Je; Sung, Kyung Rim; Kim, Chan Yun
2015-01-01
Normal-tension glaucoma (NTG) is a heterogenous disease, and there is still controversy about subclassifications of this disorder. On the basis of spectral-domain optical coherence tomography (SD-OCT), we subdivided NTG with hierarchical cluster analysis using optic nerve head (ONH) parameters and retinal nerve fiber layer (RNFL) thicknesses. A total of 200 eyes of 200 NTG patients between March 2011 and June 2012 underwent SD-OCT scans to measure ONH parameters and RNFL thicknesses. We classified NTG into homogenous subgroups based on these variables using a hierarchical cluster analysis, and compared clusters to evaluate diverse NTG characteristics. Three clusters were found after hierarchical cluster analysis. Cluster 1 (62 eyes) had the thickest RNFL and widest rim area, and showed early glaucoma features. Cluster 2 (60 eyes) was characterized by the largest cup/disc ratio and cup volume, and showed advanced glaucomatous damage. Cluster 3 (78 eyes) had small disc areas in SD-OCT and were comprised of patients with significantly younger age, longer axial length, and greater myopia than the other 2 groups. A hierarchical cluster analysis of SD-OCT scans divided NTG patients into 3 groups based upon ONH parameters and RNFL thicknesses. It is anticipated that the small disc area group comprised of younger and more myopic patients may show unique features unlike the other 2 groups.
Lee, Pei-Jung; Liu, Catherine Jui-Ling.; Wojciechowski, Robert; Bailey-Wilson, Joan E.; Cheng, Ching-Yu
2010-01-01
Purpose To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry (SLP) and visual field (VF) sensitivity in primary open angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Design Prospective, comparative, observational cases series Methods Fifty patients with POAG and 56 with PACG were examined using SLP with variable corneal compensation (GDx VCC) and Humphrey VF analyzer between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity (MS) in both decibel (dB) and 1/Lambert (L) scales, were estimated by Spearman's rank correlation coefficient (rs) and multivariate median regression models (pseudo R2). The correlations were determined globally and for six RNFL sectors and their corresponding VF regions. Results The correlation between RNFL thickness and MS (in dB) was weaker in the PACG group (rs = 0.38, P = 0.004, pseudo R2 = 0.17) than in the POAG group (rs = 0.51, P <0.001, pseudo R2 = 0.31), but the difference in the magnitude of correlation was not significant (P = 0.42).With Bonferroni correction, the structure-function correlation was significant in the superotemporal (rs = 0.62), superonasal (rs = 0.56), inferonasal (rs = 0.53), and inferotemporal (rs = 0.50) sectors in the POAG group (all P <0.001), while it was significant only in the superotemporal (rs = 0.53) and inferotemporal (rs = 0.48) sectors in the PACG group (both P <0.001). The results were similar when MS was expressed as 1/L scale. Conclusions Both POAG and PACG eyes had moderate structure-function correlations using SLP. Compared to eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. PMID:20202618
Wang, Mingwu; Lu, Ake Tzu-Hui; Varma, Rohit; Schuman, Joel S; Greenfield, David S; Huang, David
2014-03-01
To improve the diagnosis of glaucoma by combining time-domain optical coherence tomography (TD-OCT) measurements of the optic disc, circumpapillary retinal nerve fiber layer (RNFL), and macular retinal thickness. Ninety-six age-matched normal and 96 perimetric glaucoma participants were included in this observational, cross-sectional study. Or-logic, support vector machine, relevance vector machine, and linear discrimination function were used to analyze the performances of combined TD-OCT diagnostic variables. The area under the receiver-operating curve (AROC) was used to evaluate the diagnostic accuracy and to compare the diagnostic performance of single and combined anatomic variables. The best RNFL thickness variables were the inferior (AROC=0.900), overall (AROC=0.892), and superior quadrants (AROC=0.850). The best optic disc variables were horizontal integrated rim width (AROC=0.909), vertical integrated rim area (AROC=0.908), and cup/disc vertical ratio (AROC=0.890). All macular retinal thickness variables had AROCs of 0.829 or less. Combining the top 3 RNFL and optic disc variables in optimizing glaucoma diagnosis, support vector machine had the highest AROC, 0.954, followed by or-logic (AROC=0.946), linear discrimination function (AROC=0.946), and relevance vector machine (AROC=0.943). All combination diagnostic variables had significantly larger AROCs than any single diagnostic variable. There are no significant differences among the combination diagnostic indices. With TD-OCT, RNFL and optic disc variables had better diagnostic accuracy than macular retinal variables. Combining top RNFL and optic disc variables significantly improved diagnostic performance. Clinically, or-logic classification was the most practical analytical tool with sufficient accuracy to diagnose early glaucoma.
Long-term structural retinal changes in patients with optic neuritis related to multiple sclerosis.
Andersen, Maria Rene; Roar, Malte; Sejbaek, Tobias; Illes, Zsolt; Grauslund, Jakob
2017-01-01
To evaluate the long-term structural and functional outcome in patients with multiple sclerosis (MS) with and without a history of optic neuritis (ON). This was a cross-sectional study of 82 patients diagnosed with MS between 2000 and 2006 from a tertiary hospital center in Denmark. Patients gave a self-reported history of ON, and functional (visual acuity and color vision) and structural (spectra domain optical coherence tomography) markers of vision were tested. Median age and MS duration at the time of the clinical examination were 49.9 years (range 30.7-72.6 years) and 13 years (range 9-15 years), respectively. ON was not associated with impairment of visual acuity or color vision. Twenty-three patients had a history of ON in at least one eye. Compared to non-affected patients, these had a lower inferior (109 vs 113 μm, P =0.04) and temporal retinal nerve fiber layer (RNFL) thickness (56 vs 67 μm, P =0.01). In an age- and sex-adjusted logistic regression model, lower inferior and temporal RNFL were associated with a higher risk of ON (odds ratio [OR] 1.56 [95% confidence interval {CI} 1.01-2.41] and OR 1.74 [95% CI 1.10-2.77] per 10 μm decrement in RNFL thickness, respectively). Twenty patients had a history of ON in one eye. Compared to the non-affected eye, this eye had a lower RNFL (109 vs 115 μm, P =0.04) and a higher central retinal thickness/mean RNFL ratio (2.7 vs 2.4, P =0.04). Although patients with long-term MS and a previous history of ON did not have any functional loss of vision, structural neurodegeneration could be demonstrated in the affected eye.
Enders, Philip; Adler, Werner; Kiessling, David; Weber, Vincent; Schaub, Friederike; Hermann, Manuel M; Dietlein, Thomas; Cursiefen, Claus; Heindl, Ludwig M
2018-03-24
To characterize the two-dimensional parameter Bruch's membrane opening minimum rim area (BMO-MRA) in spectral domain optical coherence tomography (SD-OCT) of the optic nerve head (ONH) compared to minimum rim width (BMO-MRW) and retinal nerve fibre layer (RNFL) thickness in a large patient cohort. Case-control, cross-sectional study of 705 eyes of 445 participants. A total of 449 eyes with glaucoma, 67 eyes with ocular hypertension and 189 healthy controls, underwent SD-OCT and confocal laser scanning tomography (CSLT), visual field testing and clinical examination. Morphometric ONH parameters, visual field function and diagnostic power were compared. Main outcome measures were SD-OCT-derived BMO-MRA, BMO-MRW, RNFL thickness and CSLT-derived rim area (DM-RA). Mean ONH area was 2.11 ± 0.57 mm 2 ; mean BMO area was 1.89 ± 0.45 mm 2 . Correlation of mean deviation in visual field to morphometric parameters was ρ = 0.70, (p < 0.001) for RNFL thickness, ρ = 0.68 (p < 0.001) for BMO-MRA, ρ = 0.66 (p < 0.001) for BMO-MRW. These correlations were not significantly different (p > 0.05), while DM-RA correlated significantly worse (ρ = 0.55; p < 0.001). In receiver operating characteristics, the calculated area under the curve (AUC) and sensitivity at 90% specificity to differentiate glaucoma were 0.87% and 70.1% for BMO-MRA, 0.86% and 68.1% for RNFL thickness, 0.84% and 66.0% for BMO-MRW, 0.82% and 51.3% for DM-RA. In a heterogenous clinical cohort of glaucoma patients, all analysed SD-OCT parameters excel DM-RA of CSLT. The two-dimensional parameter BMO-MRA shows comparable levels of diagnostic power to detect glaucoma compared to established parameters BMO-MRW and RNFL thickness. Given higher comparability between ONH sizes, BMO-MRA might become an additional standard tool in SD-OCT imaging for glaucoma. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Ocular changes in primary hypothyroidism.
Ozturk, Banu T; Kerimoglu, Hurkan; Dikbas, Oguz; Pekel, Hamiyet; Gonen, Mustafa S
2009-12-29
To determine the ocular changes related to hypothyrodism in newly diagnosed patients without orbitopathy. Thirty-three patients diagnosed to have primary overt hypothyroidism were enrolled in the study. All subjects were assigned to underwent central corneal thickness (CCT), anterior chamber volume, depth and angle measurements with the Scheimpflug camera (Pentacam, Oculus) and cup to disc ratio (C/D), mean retinal thickness and mean retinal nerve fiber layer (RNFL) thickness measurements with optical coherence tomography (OCT) in addition to ophthalmological examination preceeding the replacement therapy and at the 1(st), 3(rd )and 6(th )months of treatment. The mean age of the patients included in the study were 40.58 +/- 1.32 years. The thyroid hormone levels return to normal levels in all patients during the follow-up period, however the mean intraocular pressure (IOP) revealed no significant change. The mean CCT was 538.05 +/- 3.85 mu initially and demonstrated no statistically significant change as the anterior chamber volume, depth and angle measurements did. The mean C/D ratio was 0.29 +/- 0.03 and the mean retinal thickness was 255.83 +/- 19.49 mu initially and the treatment did not give rise to any significant change. The mean RNFL thickness was also stable during the control visits, so no statistically significant change was encountered. Neither hypothyroidism, nor its replacement therapy gave rise to any change of IOP, CCT, anterior chamber parameters, RNFL, retinal thickness and C/D ratio.
Sarfraz, Muhammad Haroon; Mehboob, Mohammad Asim; Haq, Rana Intisar Ul
2017-01-01
To evaluate the correlation between Central Corneal Thickness (CCT) and Visual Field (VF) defect parameters like Mean Deviation (MD) and Pattern Standard Deviation (PSD), Cup-to-Disc Ratio (CDR) and Retinal Nerve Fibre Layer Thickness (RNFL-T) in Primary Open-Angle Glaucoma (POAG) patients. This cross sectional study was conducted at Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi from September 2015 to September 2016. Sixty eyes of 30 patients with diagnosed POAG were analysed. Correlation of CCT with other variables was studied. Mean age of study population was 43.13±7.54 years. Out of 30 patients, 19 (63.33%) were males and 11 (36.67%) were females. Mean CCT, MD, PSD, CDR and RNFL-T of study population was 528.57±25.47µm, -9.11±3.07, 6.93±2.73, 0.63±0.13 and 77.79±10.44µm respectively. There was significant correlation of CCT with MD, PSD and CDR (r=-0.52, p<0.001; r=-0.59, p<0.001;r=-0.41, p=0.001 respectively). The correlation of CCT with RNFL-T was not statistically significant (r=-0.14, p=0.284). Central corneal thickness had significant correlation with visual field parameters like mean deviation and pattern standard deviation, as well as with cup-to-disc ratio. However, central corneal thickness had no significant relationship with retinal nerve fibre layer thickness.
Ashina, Håkan; Li, Xiao Qiang; Olsen, Else Marie; Skovgaard, Anne Mette; Larsen, Michael; Munch, Inger Christine
2017-04-01
Both maternal smoking during pregnancy and low birth weight have been implicated in impaired development of the retina. To investigate the associations of maternal smoking during pregnancy and low birth weight with retinal nerve fiber layer (RNFL) thickness in preadolescent children. The Copenhagen Child Cohort 2000 Eye Study is a prospective, population-based, birth cohort study that included all children (n = 6090) born in 2000 in Copenhagen, Denmark. Maternal smoking data were collected through parental interviews. Birth weight, pregnancy, and medical history data were obtained from the Danish Medical Birth Registry. As a follow-up, the study performed eye examinations on 1406 of these children from May 1, 2011, to October 31, 2012, when the children were aged 11 or 12 years. The participants were predominantly (1296 [92.4%]) of European descent. Study data were analyzed from June 1, 2016, to October 1, 2016. Peripapillary RNFL thickness measured using optical coherence tomography at the 11- or 12-year examination. Of the 1406 children in the study, 1323 were included in the analysis (mean [SD] age was 11.7 [0.4] years; 633 [47.8%] were boys and 690 [52.2%] were girls). The mean (SD) RNFL thickness was 104 (9.6) μm. In 227 children whose mothers had smoked during pregnancy, the peripapillary RNFL was 5.7 μm (95% CI, 4.3-7.1 μm; P < .001) thinner than in children whose mothers had not smoked after correction for age, sex, birth weight, height, body weight, Tanner stage of pubertal development, axial length, and spherical equivalent refractive error. In low-birth-weight children (<2500 g), the RNFL was 3.5 μm (95% CI, 0.6-6.3 μm; P = .02) thinner than in normal-birth-weight children after adjustment for all variables. Exposure to maternal smoking during uterine life and low birth weight were independently associated with having a thinner RNFL at age 11 or 12 years. These observations support previous findings that intrauterine and perinatal factors can have long-lasting effects on the retina and the optic nerve. The results of this study add evidence to existing recommendations to avoid smoking during pregnancy and support measures that promote maternal and fetal health.
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Arakawa, Naoko; Oshima, Susumu; Shibata, Naohisa; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2012-01-01
To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created. AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001) AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.
Medeiros, Felipe A.; Alencar, Luciana M.; Zangwill, Linda M.; Bowd, Christopher; Vizzeri, Gianmarco; Sample, Pamela A.; Weinreb, Robert N.
2010-01-01
Purpose To evaluate the ability of scanning laser polarimetry with variable corneal compensation to detect progressive retinal nerve fiber layer (RNFL) loss in glaucoma patients and patients suspected of having the disease. Methods This was an observational cohort study that included 335 eyes of 195 patients. Images were obtained annually with the GDx VCC scanning laser polarimeter, along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. The median follow-up time was 3.94 years. Progression was determined using commercial software for SAP and by masked assessment of optic disc stereophotographs performed by expert graders. Random coefficient models were used to evaluate the relationship between RNFL thickness measurements over time and progression as determined by SAP and/or stereophotographs. Results From the 335 eyes, 34 (10%) showed progression over time by stereophotographs and/or SAP. Average GDx VCC measurements decreased significantly over time for both progressors as well as non-progressors. However, the rate of decline was significantly higher in the progressing group (−0.70 μm/year) compared to the non-progressing group (−0.14 μm/year; P = 0.001). Black race and male sex were significantly associated with higher rates of RNFL loss during follow-up. Conclusions The GDx VCC scanning laser polarimeter was able to identify longitudinal RNFL loss in eyes that showed progression in optic disc stereophotographs and/or visual fields. These findings suggest that this technology could be useful to detect and monitor progressive disease in patients with established diagnosis of glaucoma or suspected of having the disease. PMID:19029038
Kim, Kyung Hoon; Choi, Jaewan; Lee, Chang Hwan; Cho, Beom-Jin; Kook, Michael S.
2008-01-01
Purpose To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. Methods Fifty-three eyes with an atypical birefringence pattern (ABP) based on SLP-VCC (28 glaucomatous eyes and 25 normal healthy eyes) were enrolled in this cross-sectional study. RNFL thickness was measured by both VCC and ECC techniques, and the visual field was examined by HVFA with 24-2 full-threshold program. The relationships between RNFL measurements in superior and inferior sectors and corresponding retinal mean sensitivity were sought globally and regionally with linear regression analysis in each group. Coefficients of the determination were calculated and compared between VCC and ECC techniques. Results In eyes with ABP, R2 values for the association between SLP parameters and retinal sensitivity were 0.06-0.16 with VCC, whereas they were 0.21-0.48 with ECC. The association of RNFL thickness with retinal sensitivity was significantly better with ECC than with VCC in 5 out of 8 regression models between SLP parameters and HVF parameters (P<0.05). Conclusions The strength of the structure-function association was higher with ECC than with VCC in eyes with ABP, which suggests that the ECC algorithm is a better approach for evaluating the structure-function relationship in eyes with ABP. PMID:18323701
Zhao, Peng-Fei; Zhou, Yue-Hua; Zhang, Jing; Wei, Wen-Bin
2017-09-20
Localized macular edema and retinal nerve fiber layer (RNFL) thinning have been reported shortly after laser in situ keratomileusis (LASIK) in adults. However, it is still unclear how LASIK affects the retina of children. This study aimed to investigate the macular retina and RNFL thickness in children with refractive amblyopia who underwent femtosecond laser-assisted LASIK (FS-LASIK). In this study, we included 56 eyes of 32 patients with refractive amblyopia who underwent FS-LASIK in our hospital from January 2012 to December 2016. Foveal (foveal center retinal, parafoveal retinal, and perifoveal), macular inner retinal (superior and inferior), and peripapillary RNFL thicknesses (superior, inferior, temporal, and nasal) were measured using Fourier-domain optical coherence tomography before surgery and 1 day, 3 days, and 1 week after surgery. We divided these patients into three groups based on their refractive error: High myopic group with 22 eyes (equivalent sphere, >6.00 D), mild myopic group with 19 eyes (equivalent sphere, 0-6.00 D), and hyperopic group with 15 eyes (equivalent sphere, >+0.50 D). We compared the macular retina and RNFL thickness before and after LASIK. A paired simple t-test was used for data analysis. One week after surgery, the visual acuity for all 56 eyes of the 32 patients reached their preoperative best-corrected vision. Visual acuity improved two lines or better for 31% of the patients. The residual refractive errors in 89% of the patients were within ±0.5 D. In the high myopic group, the foveal center retinal and parafoveal retinal thicknesses were thicker 1 day and 3 days after surgery than before surgery (t = 2.689, P = 0.012; t = 2.383, P = 0.018, respectively); no significant difference was found 1 week after surgery (P > 0.05). The foveal center retinal and parafoveal retinal thicknesses were greater 1 day after surgery than they were before surgery (P = 0.000 and P = 0.005, respectively) in the mild myopic and hyperopic groups. No significant difference was found 3 days or 1 week after surgery (P > 0.05). In all three groups, no significant difference was found in the macular inner retinal or peripapillary RNFL thickness 1 day, 3 days, or 1 week after surgery (P > 0.05). The foveal center retinal edema after FS-LASIK is mild and reversible in children, that mostly occurred in the high myopic group with no effect on the visual acuity, and is always relieved within 1 week.
Optical Coherence Tomography in Alzheimer's Disease: A Meta-Analysis.
Coppola, Gianluca; Di Renzo, Antonio; Ziccardi, Lucia; Martelli, Francesco; Fadda, Antonello; Manni, Gianluca; Barboni, Piero; Pierelli, Francesco; Sadun, Alfredo A; Parisi, Vincenzo
2015-01-01
Alzheimer's disease (AD) is a neurodegenerative disorder, which is likely to start as mild cognitive impairment (MCI) several years before the its full-blown clinical manifestation. Optical coherence tomography (OCT) has been used to detect a loss in peripapillary retina nerve fiber layer (RNFL) and a reduction in macular thickness and volume of people affected by MCI or AD. Here, we performed an aggregate meta-analysis combining results from different studies. Data sources were case-control studies published between January 2001 and August 2014 (identified through PubMed and Google Scholar databases) that examined the RNFL thickness by means of OCT in AD and MCI patients compared with cognitively healthy controls. 11 studies were identified, including 380 patients with AD, 68 with MCI and 293 healthy controls (HC). The studies suggest that the mean RNFL thickness is reduced in MCI (weighted mean differences in μm, WMD = -13.39, 95% CI: -17.34 to -9.45, p = 0.031) and, even more so, in AD (WMD = -15.95, 95% CI: -21.65 to -10.21, p<0.0001) patients compared to HC. RNFL in the 4 quadrants were all significantly thinner in AD superior (superior WMD = -24.0, 95% CI: -34.9 to -13.1, p<0.0001; inferior WMD = -20.8, 95% CI: -32.0 to -9.7, p<0.0001; nasal WMD = -14.7, 95% CI: -23.9 to -5.5, p<0.0001; and temporal WMD = -10.7, 95% CI: -19.9 to -1.4, p<0.0001); the same significant reduction in quadrant RNFL was observed in MCI patients compared with HC (Inferior WMD = -20.22, 95% CI: -30.41 to -10.03, p = 0.0001; nasal WMD = -7.4, 95% CI: -10.08 to -4.7, p = 0.0000; and temporal WMD = -6.88, 95% CI: -12.62 to -1.13, p = 0.01), with the exception of superior quadrant (WMD = -19.45, 95% CI: -40.23 to 1.32, p = 0.06). Results from the meta-analysis support the important role of OCT for RNFL analysis in monitoring the progression of AD and in assessing the effectiveness of purported AD treatments.
Dotan, Gad; Kesler, Anat; Naftaliev, Elvira; Skarf, Barry
2015-05-01
To report on the correlation of structural damage to the axons of the optic nerve and visual outcome following bilateral non-arteritic anterior ischemic optic neuropathy. A retrospective review of the medical records of 25 patients with bilateral sequential non-arteritic anterior ischemic optic neuropathy was performed. Outcome measures were peripapillary retinal nerve fiber layer thickness measured with the Stratus optical coherence tomography scanner, visual acuity and visual field loss. Median peripapillary retinal nerve fiber layer (RNFL) thickness, mean deviation (MD) of visual field, and visual acuity of initially involved NAION eyes (54.00 µm, -17.77 decibels (dB), 0.4, respectively) were comparable to the same parameters measured following development of second NAION event in the other eye (53.70 µm, p = 0.740; -16.83 dB, p = 0.692; 0.4, p = 0.942, respectively). In patients with bilateral NAION, there was a significant correlation of peripapillary RNFL thickness (r = 0.583, p = 0.002) and MD of the visual field (r = 0.457, p = 0.042) for the pairs of affected eyes, whereas a poor correlation was found in visual acuity of these eyes (r = 0.279, p = 0.176). Peripapillary RNFL thickness following NAION was positively correlated with MD of visual field (r = 0.312, p = 0.043) and negatively correlated with logMAR visual acuity (r = -0.365, p = 0.009). In patients who experience bilateral NAION, the magnitude of RNFL loss is similar in each eye. There is a greater similarity in visual field loss than in visual acuity between the two affected eyes with NAION of the same individual.
Sun, Ming-Hui; Liao, Yaping Joyce
2017-09-01
The optic nerve head is vulnerable to ischemia leading to anterior ischemic optic neuropathy (AION), the most common acute optic neuropathy in those older than 50 years of age. We performed a cross-sectional study of 55 nonarteritic anterior ischemic optic neuropathy (NAION) eyes in 34 patients to assess clinical outcome and perform structure-function correlations. The peak age of NAION onset was between 50 and 55 years. Sixty-seven percent of patients presented with their first event between the ages of 40 and 60 years, and 32% presented at ≤50 years. Those with NAION onset at age ≤50 years did not have significantly better visual outcome per logMAR visual acuity, automated perimetric mean deviation (PMD) or optical coherence tomography (OCT) measurements. Kaplan-Meier survival curve and multivariate Cox proportional regression analysis showed that age >50 years at NAION onset was associated with greater risk of second eye involvement, with hazard ratio of 20. Older age at onset was significantly correlated with greater thinning of the ganglion cell complex (GCC) (P = 0.022) but not with logMAR visual acuity, PMD, or thinning of retinal nerve fiber layer (RNFL). Using area under receiver operating characteristic curve analyses, we found that thinning of RNFL and GCC was best able to predict visual outcome, and that mean RNFL thickness >65 μm or macular GCC thickness >55 μm significantly correlated with good visual field outcome. We showed that NAION onset at age >50 years had a greater risk of second eye involvement. Patients with OCT mean RNFL thickness >65 μm and mean macular ganglion cell complex thickness >55 μm had better visual outcomes.
Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P
2011-01-01
To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). The study included 330 experienced participants in five age-related groups: 77 'preperimetric' open-angle glaucoma (OAG) patients, 52 'early' OAG, 50 'moderate' OAG, 54 ocular hypertensive patients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an 'FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone.
Horn, F K; Mardin, C Y; Bendschneider, D; Jünemann, A G; Adler, W; Tornow, R P
2011-01-01
Purpose To assess the combined diagnostic power of frequency-doubling technique (FDT)-perimetry and retinal nerve fibre layer (RNFL) thickness measurements with spectral domain optical coherence tomography (SDOCT). Methods The study included 330 experienced participants in five age-related groups: 77 ‘preperimetric' open-angle glaucoma (OAG) patients, 52 ‘early' OAG, 50 ‘moderate' OAG, 54 ocular hypertensivepatients, and 97 healthy subjects. For glaucoma assessment in all subjects conventional perimetry, evaluation of fundus photographs, FDT-perimetry and RNFL thickness measurement with SDOCT was done. Glaucomatous visual field defects were classified using the Glaucoma Staging System. FDT evaluation used a published method with casewise calculation of an ‘FDT-score', including all missed localized probability levels. SDOCT evaluation used mean RNFL thickness and a new individual SDOCT-score considering normal confidence limits in 32 sectors of a peripapillary circular scan. To examine the joined value of both methods a combined score was introduced. Significance of the difference between Receiver-operating-characteristic (ROC) curves was calculated for a specificity of 96%. Results Sensitivity in the preperimetric glaucoma group was 44% for SDOCT-score, 25% for FDT-score, and 44% for combined score, in the early glaucoma group 83, 81, and 89%, respectively, and in the moderate glaucoma group 94, 94, and 98%, respectively, all at a specificity of 96%. ROC performance of the newly developed combined score is significantly above single ROC curves of FDT-score in preperimetric and early OAG and above RNFL thickness in moderate OAG. Conclusion Combination of function and morphology by using the FDT-score and the SDOCT-score performs equal or even better than each single method alone. PMID:21102494
Arikan, Sedat; Gokmen, Ferhat; Comez, Arzu Taskiran; Gencer, Baran; Kara, Selcuk; Akbal, Ayla
2015-01-01
The contrast sensitivity (CS) function in patients with primary Sjögren's syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage.
Ocular changes in primary hypothyroidism
2009-01-01
Background To determine the ocular changes related to hypothyrodism in newly diagnosed patients without orbitopathy. Findings Thirty-three patients diagnosed to have primary overt hypothyroidism were enrolled in the study. All subjects were assigned to underwent central corneal thickness (CCT), anterior chamber volume, depth and angle measurements with the Scheimpflug camera (Pentacam, Oculus) and cup to disc ratio (C/D), mean retinal thickness and mean retinal nerve fiber layer (RNFL) thickness measurements with optical coherence tomography (OCT) in addition to ophthalmological examination preceeding the replacement therapy and at the 1st, 3rd and 6th months of treatment. The mean age of the patients included in the study were 40.58 ± 1.32 years. The thyroid hormone levels return to normal levels in all patients during the follow-up period, however the mean intraocular pressure (IOP) revealed no significant change. The mean CCT was 538.05 ± 3.85 μ initially and demonstrated no statistically significant change as the anterior chamber volume, depth and angle measurements did. The mean C/D ratio was 0.29 ± 0.03 and the mean retinal thickness was 255.83 ± 19.49 μ initially and the treatment did not give rise to any significant change. The mean RNFL thickness was also stable during the control visits, so no statistically significant change was encountered. Conclusions Neither hypothyroidism, nor its replacement therapy gave rise to any change of IOP, CCT, anterior chamber parameters, RNFL, retinal thickness and C/D ratio. PMID:20040111
Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis.
Kansal, Vinay; Armstrong, James J; Pintwala, Robert; Hutnik, Cindy
2018-01-01
Early detection, monitoring and understanding of changes in the retina are central to the diagnosis of glaucomatous optic neuropathy, and vital to reduce visual loss from this progressive condition. The main objective of this investigation was to compare glaucoma diagnostic accuracy of commercially available optical coherence tomography (OCT) devices (Zeiss Stratus, Zeiss Cirrus, Heidelberg Spectralis and Optovue RTVue, and Topcon 3D-OCT). 16,104 glaucomatous and 11,543 normal eyes reported in 150 studies. Between Jan. 2017 and Feb 2017, MEDLINE®, EMBASE®, CINAHL®, Cochrane Library®, Web of Science®, and BIOSIS® were searched for studies assessing glaucoma diagnostic accuracy of the aforementioned OCT devices. Meta-analysis was performed pooling area under the receiver operating characteristic curve (AUROC) estimates for all devices, stratified by OCT type (RNFL, macula), and area imaged. 150 studies with 16,104 glaucomatous and 11,543 normal control eyes were included. Key findings: AUROC of glaucoma diagnosis for RNFL average for all glaucoma patients was 0.897 (0.887-0.906, n = 16,782 patient eyes), for macula ganglion cell complex (GCC) was 0.885 (0.869-0.901, n = 4841 eyes), for macula ganglion cell inner plexiform layer (GCIPL) was 0.858 (0.835-0.880, n = 4211 eyes), and for total macular thickness was 0.795 (0.754-0.834, n = 1063 eyes). The classification capability was similar across all 5 OCT devices. More diagnostically favorable AUROCs were demonstrated in patients with increased glaucoma severity. Diagnostic accuracy of RNFL and segmented macular regions (GCIPL, GCC) scans were similar and higher than total macular thickness. This study provides a synthesis of contemporary evidence with features of robust inclusion criteria and large sample size. These findings may provide guidance to clinicians when navigating this rapidly evolving diagnostic area characterized by numerous options.
Fibromyalgia Is Correlated with Retinal Nerve Fiber Layer Thinning.
Garcia-Martin, Elena; Garcia-Campayo, Javier; Puebla-Guedea, Marta; Ascaso, Francisco J; Roca, Miguel; Gutierrez-Ruiz, Fernando; Vilades, Elisa; Polo, Vicente; Larrosa, Jose M; Pablo, Luis E; Satue, Maria
2016-01-01
To investigate whether fibromyalgia induces axonal damage in the optic nerve that can be detected using optical coherence tomography (OCT), as the retinal nerve fiber layer (RNFL) is atrophied in patients with fibromyalgia compared with controls. Fibromyalgia patients (n = 116) and age-matched healthy controls (n = 144) were included in this observational and prospective cohort study. All subjects underwent visual acuity measurement and structural analysis of the RNFL using two OCT devices (Cirrus and Spectralis). Fibromyalgia patients were evaluated according to Giesecke's fibromyalgia subgroups, the Fibromyalgia Impact Questionnaire (FIQ), and the European Quality of Life-5 Dimensions (EQ5D) scale. We compared the differences between fibromyalgia patients and controls, and analyzed the correlations between OCT measurements, disease duration, fibromyalgia subgroups, severity, and quality of life. The impact on quality of life in fibromyalgia subgroups and in patients with different disease severity was also analyzed. A significant decrease in the RNFL was detected in fibromyalgia patients compared with controls using the two OCT devices: Cirrus OCT ganglion cell layer analysis registered a significant decrease in the minimum thickness of the inner plexiform layer (74.99±16.63 vs 79.36±3.38 μm, respectively; p = 0.023), nasal inferior, temporal inferior and temporal superior sectors (p = 0.040; 0.011 and 0.046 respectively). The Glaucoma application of the Spectralis OCT revealed thinning in the nasal, temporal inferior and temporal superior sectors (p = 0.009, 0.006, and 0.002 respectively) of fibromyalgia patients and the Axonal application in all sectors, except the nasal superior and temporal sectors. The odds ratio (OR) to estimate the size effect of FM in RNFL thickness was 1.39. RNFL atrophy was detected in patients with FIQ scores <60 (patients in early disease stages) compared with controls in the temporal inferior sector (78.74±17.75 vs 81.65±3.61; p = 0.020) and the temporal superior sector (78.20±14.50 vs 80.74±3.88; p = 0.039) with Cirrus OCT; in the temporal inferior sector (145.85±24.32 vs 150.18±19.71; p = 0.012) and temporal superior sector (131.54±20.53 vs 138.13±16.67; p = 0.002) with the Glaucoma application of the Spectralis OCT; and in all sectors, except the average, nasal superior, and temporal sectors, and parameters with the Axonal application of the Spectralis OCT. Temporal inferior RNFL thickness was significantly reduced in patients with severe fibromyalgia (FIQ≥60) compared with patients with mild fibromyalgia (FIQ<60; 145.85±24.32 vs 138.99±18.09 μm, respectively; 145.43±13.21 vs 139.85±13.09 μm, p = 0.032 with the Glaucoma application and p = 0.021 with the Axonal application). The subgroup with biologic fibromyalgia exhibited significant thinning in the temporal inferior and superior sectors (115.17±20.82 μm and 117.05±24.19 μm, respectively) compared with the depressive (130.83±22.97 μm and 127.71±26.10 μm, respectively) and atypical (128.60±26.54 μm and 125.55±23.65 μm, respectively) subgroups (p = 0.005 and 0.001 respectively). Fibromyalgia causes subclinical axonal damage in the RNFL that can be detected using innocuous and non-invasive OCT, even in the early disease stages. The impact on the RNFL in the temporal sectors is greater in patients with biologic fibromyalgia, suggesting the presence of neurodegenerative processes in this subgroup of patients with fibromyalgia.
Fibromyalgia Is Correlated with Retinal Nerve Fiber Layer Thinning
Garcia-Martin, Elena; Garcia-Campayo, Javier; Puebla-Guedea, Marta; Ascaso, Francisco J.; Roca, Miguel; Gutierrez-Ruiz, Fernando; Vilades, Elisa; Polo, Vicente; Larrosa, Jose M.; Pablo, Luis E.; Satue, Maria
2016-01-01
Objective To investigate whether fibromyalgia induces axonal damage in the optic nerve that can be detected using optical coherence tomography (OCT), as the retinal nerve fiber layer (RNFL) is atrophied in patients with fibromyalgia compared with controls. Methods Fibromyalgia patients (n = 116) and age-matched healthy controls (n = 144) were included in this observational and prospective cohort study. All subjects underwent visual acuity measurement and structural analysis of the RNFL using two OCT devices (Cirrus and Spectralis). Fibromyalgia patients were evaluated according to Giesecke’s fibromyalgia subgroups, the Fibromyalgia Impact Questionnaire (FIQ), and the European Quality of Life-5 Dimensions (EQ5D) scale. We compared the differences between fibromyalgia patients and controls, and analyzed the correlations between OCT measurements, disease duration, fibromyalgia subgroups, severity, and quality of life. The impact on quality of life in fibromyalgia subgroups and in patients with different disease severity was also analyzed. Results A significant decrease in the RNFL was detected in fibromyalgia patients compared with controls using the two OCT devices: Cirrus OCT ganglion cell layer analysis registered a significant decrease in the minimum thickness of the inner plexiform layer (74.99±16.63 vs 79.36±3.38 μm, respectively; p = 0.023), nasal inferior, temporal inferior and temporal superior sectors (p = 0.040; 0.011 and 0.046 respectively). The Glaucoma application of the Spectralis OCT revealed thinning in the nasal, temporal inferior and temporal superior sectors (p = 0.009, 0.006, and 0.002 respectively) of fibromyalgia patients and the Axonal application in all sectors, except the nasal superior and temporal sectors. The odds ratio (OR) to estimate the size effect of FM in RNFL thickness was 1.39. RNFL atrophy was detected in patients with FIQ scores <60 (patients in early disease stages) compared with controls in the temporal inferior sector (78.74±17.75 vs 81.65±3.61; p = 0.020) and the temporal superior sector (78.20±14.50 vs 80.74±3.88; p = 0.039) with Cirrus OCT; in the temporal inferior sector (145.85±24.32 vs 150.18±19.71; p = 0.012) and temporal superior sector (131.54±20.53 vs 138.13±16.67; p = 0.002) with the Glaucoma application of the Spectralis OCT; and in all sectors, except the average, nasal superior, and temporal sectors, and parameters with the Axonal application of the Spectralis OCT. Temporal inferior RNFL thickness was significantly reduced in patients with severe fibromyalgia (FIQ≥60) compared with patients with mild fibromyalgia (FIQ<60; 145.85±24.32 vs 138.99±18.09 μm, respectively; 145.43±13.21 vs 139.85±13.09 μm, p = 0.032 with the Glaucoma application and p = 0.021 with the Axonal application). The subgroup with biologic fibromyalgia exhibited significant thinning in the temporal inferior and superior sectors (115.17±20.82 μm and 117.05±24.19 μm, respectively) compared with the depressive (130.83±22.97 μm and 127.71±26.10 μm, respectively) and atypical (128.60±26.54 μm and 125.55±23.65 μm, respectively) subgroups (p = 0.005 and 0.001 respectively). Conclusions Fibromyalgia causes subclinical axonal damage in the RNFL that can be detected using innocuous and non-invasive OCT, even in the early disease stages. The impact on the RNFL in the temporal sectors is greater in patients with biologic fibromyalgia, suggesting the presence of neurodegenerative processes in this subgroup of patients with fibromyalgia. PMID:27584145
Green disease in optical coherence tomography diagnosis of glaucoma.
Sayed, Mohamed S; Margolis, Michael; Lee, Richard K
2017-03-01
Optical coherence tomography (OCT) has become an integral component of modern glaucoma practice. Utilizing color codes, OCT analysis has rendered glaucoma diagnosis and follow-up simpler and faster for the busy clinician. However, green labeling of OCT parameters suggesting normal values may confer a false sense of security, potentially leading to missed diagnoses of glaucoma and/or glaucoma progression. Conditions in which OCT color coding may be falsely negative (i.e., green disease) are identified. Early glaucoma in which retinal nerve fiber layer (RNFL) thickness and optic disc parameters, albeit labeled green, are asymmetric in both eyes may result in glaucoma being undetected. Progressively decreasing RNFL thickness may reveal the presence of progressive glaucoma that, because of green labeling, can be missed by the clinician. Other ocular conditions that can increase RNFL thickness can make the diagnosis of coexisting glaucoma difficult. Recently introduced progression analysis features of OCT may help detect green disease. Recognition of green disease is of paramount importance in diagnosing and treating glaucoma. Understanding the limitations of imaging technologies coupled with evaluation of serial OCT analyses, prompt clinical examination, and structure-function correlation is important to avoid missing real glaucoma requiring treatment.
Han, Mei; Zhao, Chen; Han, Quan-Hong; Xie, Shiyong; Li, Yan
2016-08-01
To examine the changes of non-arteritic anterior ischemic optic neuropathy (NAION) by serial morphometry using Fourier domain optical coherence tomography (FD-OCT). Retrospective study in patients with newly diagnosed NAION (n=33, all unilateral) and controls (n=75 unilateral NAION patients with full contralateral eye vision) who underwent FD-OCT of the optic disk, optic nerve head (ONH), and macula within 1 week of onset and again 1, 3, 6, and 12 months later. The patients showed no improvement in vision during follow-up. Within 1 week of onset, all NAION eyes exhibited severe ONH fiber crowding and peripapillary retinal nerve fiber layer (RNFL) edema. Four had subretinal fluid accumulation and 12 had posterior vitreous detachment (PVD) at the optic disc surface. Ganglion cell complex (GCC) and RNFL thicknesses were reduced at 1 and 3 months (p < 0.05), with no deterioration thereafter. Initial RNFL/GCC contraction magnitude in the superior hemisphere correlated with the severity of inferior visual field deficits. NAION progression is characterized by an initial phase of accelerated RNFL and GCC deterioration. These results reveal that the kinetic change of neural retina in NAION and may have implication on the time window for treatment of NAION. FD-OCT is useful in the evaluation of NAION.
Diagnostic capability of retinal thickness measures in diabetic peripheral neuropathy.
Srinivasan, Sangeetha; Pritchard, Nicola; Sampson, Geoff P; Edwards, Katie; Vagenas, Dimitrios; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
To examine the diagnostic capability of the full retinal and inner retinal thickness measures in differentiating individuals with diabetic peripheral neuropathy (DPN) from those without neuropathy and non-diabetic controls. Individuals with (n=44) and without (n=107) diabetic neuropathy and non-diabetic control (n=42) participants underwent spectral domain optical coherence tomography (SDOCT). Retinal thickness in the central 1mm zone (including the fovea), parafovea and perifovea was assessed in addition to ganglion cell complex (GCC) global loss volume (GCC GLV) and focal loss volume (GCC FLV), and retinal nerve fiber layer (RNFL) thickness. Diabetic neuropathy was defined using a modified neuropathy disability score (NDS) recorded on a 0-10 scale, wherein, NDS ≥3 indicated neuropathy and NDS indicated <3 no neuropathy. Diagnostic performance was assessed by areas under the receiver operating characteristic curves (AUCs), 95 per cent confidence intervals (CI), sensitivities at fixed specificities, positive likelihood ratio (+LR), negative likelihood ratio (-LR) and the cut-off points for the best AUCs obtained. The AUC for GCC FLV was 0.732 (95% CI: 0.624-0.840, p<0.001) with a sensitivity of 53% and specificity of 80% for differentiating DPN from controls. Evaluation of the LRs showed that GCC FLV was associated with only small effects on the post-test probability of the disease. The cut-off point calculated using the Youden index was 0.48% (67% sensitivity and 73% specificity) for GCC FLV. For distinguishing those with neuropathy from those without neuropathy, the AUCs of retinal parameters ranged from 0.508 for the central zone to 0.690 for the inferior RNFL thickness. For distinguishing those with moderate or advanced neuropathy from those with mild or no neuropathy, the inferior RNFL thickness demonstrated the highest AUC of 0.820, (95% CI: 0.731-0.909, p<0.001) with a sensitivity of 69% and 80% specificity. The cut-off-point for the inferior RNFL thickness was 97μm, with 81% sensitivity and 72% specificity. The GCC FLV can differentiate individuals with diabetic neuropathy from healthy controls, while the inferior RNFL thickness is able to differentiate those with greater degrees of neuropathy from those with mild or no neuropathy, both with an acceptable level of accuracy. Optical coherence tomography represents a non-invasive technology that aids in detection of retinal structural changes in patients with established diabetic neuropathy. Further refinement of the technique and the analytical approaches may be required to identify patients with minimal neuropathy. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.
Kupersmith, Mark J; Anderson, Susan; Durbin, Mary; Kardon, Randy
2013-08-15
Scanning laser polarimetry (SLP) reveals abnormal retardance of birefringence in locations of the edematous peripapillary retinal nerve fiber layer (RNFL), which appear thickened by optical coherence tomography (OCT), in nonarteritic anterior ischemic optic neuropathy (NAION). We hypothesize initial sector SLP RNFL abnormalities will correlate with long-term regional visual field loss due to ischemic injury. We prospectively performed automated perimetry, SLP, and high definition OCT (HD-OCT) of the RNFL in 25 eyes with acute NAION. We grouped visual field threshold and RNFL values into Garway-Heath inferior/superior disc sectors and corresponding superior/inferior field regions. We compared sector SLP RNFL thickness with corresponding visual field values at presentation and at >3 months. At presentation, 12 eyes had superior sector SLP reduction, 11 of which had inferior field loss. Six eyes, all with superior field loss, had inferior sector SLP reduction. No eyes had reduced OCT-derived RNFL acutely. Eyes with abnormal field regions had corresponding SLP sectors thinner (P = 0.003) than for sectors with normal field regions. During the acute phase, the SLP-derived sector correlated with presentation (r = 0.59, P = 0.02) and with >3-month after presentation (r = 0.44, P = 0.02) corresponding superior and inferior field thresholds. Abnormal RNFL birefringence occurs in sectors corresponding to regional visual field loss during acute NAION when OCT-derived RNFL shows thickening. Since the visual field deficits show no significant recovery, SLP can be an early marker for axonal injury, which may be used to assess recovery potential at RNFL locations with respect to new treatments for acute NAION.
Lee, Pei-Jung; Liu, Catherine Jui-Ling; Wojciechowski, Robert; Bailey-Wilson, Joan E; Cheng, Ching-Yu
2010-05-01
To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry and visual field (VF) sensitivity in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Prospective, comparative, observational cases series. Fifty patients with POAG and 56 patients with PACG were examined using scanning laser polarimetry with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, Inc.) and Humphrey VF analyzer (Carl Zeiss Meditec, Inc.) between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity in both decibel and 1/Lambert scales, were estimated by the Spearman rank correlation coefficient (r(s)) and multivariate median regression models (pseudo R(2)). The correlations were determined globally and for 6 RNFL sectors and their corresponding VF regions. The correlation between RNFL thickness and mean sensitivity (in decibels) was weaker in the PACG group (r(s) = 0.38; P = .004; pseudo R(2) = 0.17) than in the POAG group (r(s) = 0.51; P < .001; pseudo R(2) = .31), but the difference in the magnitude of correlation was not significant (P = .42). With Bonferroni correction, the structure-function correlation was significant in the superotemporal (r(s) = 0.62), superonasal (r(s) = 0.56), inferonasal (r(s) = 0.53), and inferotemporal (r(s) = 0.50) sectors in the POAG group (all P < .001), whereas it was significant only in the superotemporal (r(s) = 0.53) and inferotemporal (r(s) = 0.48) sectors in the PACG group (both P < .001). The results were similar when mean sensitivity was expressed as 1/Lambert scale. Both POAG and PACG eyes had moderate structure-function correlations using scanning laser polarimetry. Compared with eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.
Long-term structural retinal changes in patients with optic neuritis related to multiple sclerosis
Andersen, Maria Rene; Roar, Malte; Sejbaek, Tobias; Illes, Zsolt; Grauslund, Jakob
2017-01-01
Purpose To evaluate the long-term structural and functional outcome in patients with multiple sclerosis (MS) with and without a history of optic neuritis (ON). Methods This was a cross-sectional study of 82 patients diagnosed with MS between 2000 and 2006 from a tertiary hospital center in Denmark. Patients gave a self-reported history of ON, and functional (visual acuity and color vision) and structural (spectra domain optical coherence tomography) markers of vision were tested. Results Median age and MS duration at the time of the clinical examination were 49.9 years (range 30.7–72.6 years) and 13 years (range 9–15 years), respectively. ON was not associated with impairment of visual acuity or color vision. Twenty-three patients had a history of ON in at least one eye. Compared to non-affected patients, these had a lower inferior (109 vs 113 μm, P=0.04) and temporal retinal nerve fiber layer (RNFL) thickness (56 vs 67 μm, P=0.01). In an age- and sex-adjusted logistic regression model, lower inferior and temporal RNFL were associated with a higher risk of ON (odds ratio [OR] 1.56 [95% confidence interval {CI} 1.01–2.41] and OR 1.74 [95% CI 1.10–2.77] per 10 μm decrement in RNFL thickness, respectively). Twenty patients had a history of ON in one eye. Compared to the non-affected eye, this eye had a lower RNFL (109 vs 115 μm, P=0.04) and a higher central retinal thickness/mean RNFL ratio (2.7 vs 2.4, P=0.04). Conclusion Although patients with long-term MS and a previous history of ON did not have any functional loss of vision, structural neurodegeneration could be demonstrated in the affected eye. PMID:28860702
Mase, Tomoko; Ishibazawa, Akihiro; Nagaoka, Taiji; Yokota, Harumasa; Yoshida, Akitoshi
2016-07-01
We quantitatively analyzed the features of a radial peripapillary capillary (RPC) network visualized using wide-field montage optical coherence tomography (OCT) angiography in healthy human eyes. Twenty eyes of 20 healthy subjects were recruited. En face 3 × 3-mm OCT angiograms of multiple locations in the posterior pole were acquired using the RTVue XR Avanti, and wide-field montage images of the RPC were created. To evaluate the RPC density, the montage images were binarized and skeletonized. The correlation between the RPC density and the retinal nerve fiber layer (RNFL) thickness measured by an OCT circle scan was investigated. The RPC at the temporal retina was detected as far as 7.6 ± 0.7 mm from the edge of the optic disc but not around the perifoveal area within 0.9 ± 0.1 mm of the fovea. Capillary-free zones beside the first branches of the arterioles were significantly (P < 0.0001) narrower than those beside the second ones. The RPC densities at 0.5, 2.5, and 5 mm from the optic disc edge were 13.6 ± 0.8, 11.9 ± 0.9, and 10.4 ± 0.9 mm-1. The RPC density also was correlated significantly (r = 0.64, P < 0.0001) with the RNFL thickness, with the greatest density in the inferotemporal region. Montage OCT angiograms can visualize expansion of the RPC network. The RPC is present in the superficial peripapillary retina in proportion to the RNFL thickness, supporting the idea that the RPC may be the vascular network primarily responsible for RNFL nourishment.
Choi, Yun Jeong; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung
2016-03-01
To determine and validate the diagnostic ability of a linear discriminant function (LDF) based on retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL) thickness obtained using high-definition optical coherence tomography (Cirrus HD-OCT) for discriminating between healthy controls and early glaucoma subjects. We prospectively selected 214 healthy controls and 152 glaucoma subjects (teaching set) and another independent sample of 86 healthy controls and 71 glaucoma subjects (validating set). Two scans, including 1 macular and 1 peripapillary RNFL scan, were obtained. After calculating the LDF in the teaching set using the binary logistic regression analysis, receiver operating characteristic curves were plotted and compared between the OCT-provided parameters and LDF in the validating set. The proposed LDF was 16.529-(0.132×superior RNFL)-(0.064×inferior RNFL)+(0.039×12 o'clock RNFL)+(0.038×1 o'clock RNFL)+(0.084×superior GCIPL)-(0.144×minimum GCIPL). The highest area under the receiver operating characteristic (AUROC) curve was obtained for LDF in both sets (AUROC=0.95 and 0.96). In the validating set, the LDF showed significantly higher AUROC than the best RNFL (inferior RNFL=0.91) and GCIPL parameter (minimum GCIPL=0.88). The LDF yielded a sensitivity of 93.0% at a fixed specificity of 85.0%. The LDF showed better diagnostic ability for differentiating between healthy and early glaucoma subjects than individual OCT parameters. A classification algorithm based on the LDF can be used in the OCT analysis for glaucoma diagnosis.
Grewal, Dilraj S; Tanna, Angelo P
2013-03-01
With the rapid adoption of spectral domain optical coherence tomography (SDOCT) in clinical practice and the recent advances in software technology, there is a need for a review of the literature on glaucoma detection and progression analysis algorithms designed for the commercially available instruments. Peripapillary retinal nerve fiber layer (RNFL) thickness and macular thickness, including segmental macular thickness calculation algorithms, have been demonstrated to be repeatable and reproducible, and have a high degree of diagnostic sensitivity and specificity in discriminating between healthy and glaucomatous eyes across the glaucoma continuum. Newer software capabilities such as glaucoma progression detection algorithms provide an objective analysis of longitudinally obtained structural data that enhances our ability to detect glaucomatous progression. RNFL measurements obtained with SDOCT appear more sensitive than time domain OCT (TDOCT) for glaucoma progression detection; however, agreement with the assessments of visual field progression is poor. Over the last few years, several studies have been performed to assess the diagnostic performance of SDOCT structural imaging and its validity in assessing glaucoma progression. Most evidence suggests that SDOCT performs similarly to TDOCT for glaucoma diagnosis; however, SDOCT may be superior for the detection of early stage disease. With respect to progression detection, SDOCT represents an important technological advance because of its improved resolution and repeatability. Advancements in RNFL thickness quantification, segmental macular thickness calculation and progression detection algorithms, when used correctly, may help to improve our ability to diagnose and manage glaucoma.
Chen, Chieh-Li; Bojikian, Karine D; Wen, Joanne C; Zhang, Qinqin; Xin, Chen; Mudumbai, Raghu C; Johnstone, Murray A; Chen, Philip P; Wang, Ruikang K
2017-05-01
Understanding the differences in vascular microcirculation of the peripapillary retinal nerve fiber layer (RNFL) between the hemispheres in eyes with glaucoma with single-hemifield visual field (VF) defects may provide insight into the pathophysiology of glaucoma. To investigate the changes in the microcirculation of the peripapillary RNFL of eyes with glaucoma by using optical microangiography. Eyes with glaucoma and single-hemifield VF defect and normal eyes underwent scanning using an optical microangiography system covering a 6.7 × 6.7-mm2 area centered at the optic nerve head. The RNFL microcirculation was measured within an annulus region centered at the optic nerve head divided into superior and inferior hemispheres. Blood flux index (the mean flow signal intensity in the vessels) and vessel area density (the percentage of the detected vessels in the annulus) were measured. Differences in microcirculation between the hemispheres in eyes with glaucoma and normal eyes and correlations among blood flow metrics, VF thresholds, and clinical optical coherence tomography structural measurements were assessed. Twenty-one eyes from 21 patients with glaucoma (7 men and 14 women; mean [SD] age, 63.7 [9.9] years) and 20 eyes from 20 healthy control individuals (9 men and 11 women; mean [SD] age, 68.3 [10.7] years) were studied. In eyes with glaucoma, the abnormal hemisphere showed a thinner RNFL (mean [SE] difference, 23.5 [4.5] μm; 95% CI, 15.1-32.0 µm; P < .001), lower RNFL blood flux index (mean [SE] difference, 0.04 [0.01]; 95% CI, 0.02-0.05; P < .001), and less vessel area density (mean [SE] difference, 0.08% [0.02%]; 95% CI, 0.05%-0.10%; P < .001) than did the normal hemisphere. Compared with normal eyes, reduced RNFL microcirculation was found in the normal hemisphere of eyes with glaucoma, measured by mean [SE] differences in blood flux index (0.06 [0.01]; 95% CI, 0.04-0.09; P < .001) and vessel area density (0.04% [0.02%]; 95% CI, 0.02%-0.08%; P = .003) but not in RNFL thickness (3.4 [4.7] μm; 95% CI, -6.2 to 12.9 µm; P = .48). Strong correlations were found between the blood flux index and VF mean deviation (Spearman ρ = 0.44; P = .045) and RNFL thickness (Spearman ρ = 0.65; P = .001) in the normal hemisphere of the eye with glaucoma. Reduced RNFL microcirculation was detected in the normal hemisphere of eyes with glaucoma, with strong correspondence with VF loss and RNFL thinning. Although the results suggest that vascular dysfunction precedes structural changes seen in glaucoma, longitudinal studies would be needed to confirm this finding.
Ara, Mirian; Ferreras, Antonio; Pajarin, Ana B; Calvo, Pilar; Figus, Michele; Frezzotti, Paolo
2015-01-01
To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.
Tak, Ali Zeynel Abidin; Sengul, Yıldızhan; Bilak, Şemsettin
2018-03-01
The aim of our study is to assess retinal nerve fiber layer (RNFL), the ganglion cell layer (GCL), inner-plexiform layer (IPL), and choroidal layer in migraine patients with white matter lesion (WML) or without WML, using spectral domain optical coherence tomography (OCT). To our study, 77 migraine patients who are diagnosed with migraine in accordance to the International Classification of Headache Disorders (ICHD)-3 beta and 43 healthy control are included. In accordance to cranial MRI, migraine patients are divided into two groups as those who have white matter lesions (39 patients), and those who do not have a lesion (38 patients). OCT was performed for participants. The average age of participants was comparable. The RNFL average thickness parameter in the migraine group was significantly lower than in the control group (p < 0.01). However, no significant difference was detected among those migraine patients who have WML, and those who do not have. No significant difference is detected among all groups in terms of IPL, GCL, and choroidal layer measuring scales. The proofs showing that affected retinal nerve fiber layer are increased in migraine patients. However, it is not known whether this may affect other layers of retina, or whether there is a correlation between affected retinal structures and white matter lesions. In our study, we found thinner RNFL in migraine patients when we compared with controls but IPL, GCL, and choroid layer values were similar between each patient groups and controls. Also, all parameters were similar between patients with WML and without WML. Studies in this regard are required.
Zhao, Peng-Fei; Zhou, Yue-Hua; Zhang, Jing; Wei, Wen-Bin
2017-01-01
Background: Localized macular edema and retinal nerve fiber layer (RNFL) thinning have been reported shortly after laser in situ keratomileusis (LASIK) in adults. However, it is still unclear how LASIK affects the retina of children. This study aimed to investigate the macular retina and RNFL thickness in children with refractive amblyopia who underwent femtosecond laser-assisted LASIK (FS-LASIK). Methods: In this study, we included 56 eyes of 32 patients with refractive amblyopia who underwent FS-LASIK in our hospital from January 2012 to December 2016. Foveal (foveal center retinal, parafoveal retinal, and perifoveal), macular inner retinal (superior and inferior), and peripapillary RNFL thicknesses (superior, inferior, temporal, and nasal) were measured using Fourier-domain optical coherence tomography before surgery and 1 day, 3 days, and 1 week after surgery. We divided these patients into three groups based on their refractive error: High myopic group with 22 eyes (equivalent sphere, >6.00 D), mild myopic group with 19 eyes (equivalent sphere, 0–6.00 D), and hyperopic group with 15 eyes (equivalent sphere, >+0.50 D). We compared the macular retina and RNFL thickness before and after LASIK. A paired simple t-test was used for data analysis. Results: One week after surgery, the visual acuity for all 56 eyes of the 32 patients reached their preoperative best-corrected vision. Visual acuity improved two lines or better for 31% of the patients. The residual refractive errors in 89% of the patients were within ±0.5 D. In the high myopic group, the foveal center retinal and parafoveal retinal thicknesses were thicker 1 day and 3 days after surgery than before surgery (t = 2.689, P = 0.012; t = 2.383, P = 0.018, respectively); no significant difference was found 1 week after surgery (P > 0.05). The foveal center retinal and parafoveal retinal thicknesses were greater 1 day after surgery than they were before surgery (P = 0.000 and P = 0.005, respectively) in the mild myopic and hyperopic groups. No significant difference was found 3 days or 1 week after surgery (P > 0.05). In all three groups, no significant difference was found in the macular inner retinal or peripapillary RNFL thickness 1 day, 3 days, or 1 week after surgery (P > 0.05). Conclusions: The foveal center retinal edema after FS-LASIK is mild and reversible in children, that mostly occurred in the high myopic group with no effect on the visual acuity, and is always relieved within 1 week. PMID:28875960
Luo, Xunda; Patel, Nimesh B.; Rajagopalan, Lakshmi P.; Harwerth, Ronald S.; Frishman, Laura J.
2014-01-01
Purpose. We investigated relations between macular retinal ganglion cell plus inner plexiform layer (RGC+IPL) thickness and macular retinal function revealed by multifocal electroretinonography (mfERG) in a nonhuman primate model of experimental glaucoma. Methods. Retinal ganglion cell (RGC) structure and function were followed with spectral-domain optical coherence tomography (SD-OCT) and ERGs in five macaques with unilateral experimental glaucoma. Linear regression was used to study correlations in control (Con) and experimental (Exp) eyes between peripapillary retinal nerve fiber layer (RNFL) thickness, macular RGC+IPL thickness, multifocal photopic negative response (mfPhNR) and high-frequency multifocal oscillatory potentials (mfOP) in slow-sequence mfERG, and low-frequency component (mfLFC) in global-flash mfERG. We used ANOVA and paired t-tests to compare glaucoma-related mfERG changes between superior and inferior hemifields, foveal hexagon, inner three rings, and four quadrants of macula. Results. Average macular RGC+IPL and temporal RNFL thickness were strongly correlated (r2 = 0.90, P < 0.001). In hexagon-by-hexagon analysis, all three mfERG measures were correlated (P < 0.001) with RGC+IPL thickness for Con (r2, 0.33–0.51) and Exp eyes (r2, 0.17–0.35). The RGC structural and functional metrics decreased as eccentricity increased. The reduction in amplitude of mfERG measures in Exp eyes relative to Con eyes was proportionally greater, in general, than the relative thinning of RGC+IPL at the same location for eyes in which structural loss was not evident, or mild to moderate. Although not statistically significant, percent amplitude reduction of mfERG measures was greatest in the inferior temporal quadrant. Conclusions. Macular RGC+IPL thickness and mfERG measures of RGC function can be complementary tools in assessing glaucomatous neuropathy. PMID:24970256
Frau, Jessica; Fenu, Giuseppe; Signori, Alessio; Coghe, Giancarlo; Lorefice, Lorena; Barracciu, Maria Antonietta; Sechi, Vincenzo; Cabras, Federico; Badas, Mauro; Marrosu, Maria Giovanna; Cocco, Eleonora
2018-05-11
The principal biomarker of neurodegeneration in multiple sclerosis (MS) is believed to be brain volume, which is associated with cognitive functions and retinal nerve fibre layer (RNFL). A cross-sectional and longitudinal assessment of the relationship between RNFL, cognitive functions and brain volume. At baseline, relapsing patients and healthy controls underwent 1.5 T MRI to estimate the normalized volume of brain (NBV), grey (NGV), white (NWV) and peripheral grey (pNGV) matter. Cognitive functions were evaluated by BICAMS, RNFL by Spectral-Domain OCT. Patients were re-evaluated after 12 months. Cognitive functions, brain volume, and RNFL differed between the group of 66 patients and that of 16 healthy controls. In the MS group, at baseline, an association was found between: p-NGV and symbol-digit (SDMT) (p = 0.022); temporal-RNFL and NBV (p = 0.007), NWV (p = 0.012), NGV (p = 0.048), and p-NGV (p = 0.021); papillo-macular bundle-RNFL and NBV (p = 0.013), NWV (p = 0.02), NGV (p = 0.049), and p-NGV (p = 0.032). Over the observational period, we found a reduction of brain volume (p < 0.001), average-RNFL (p = 0.001), temporal-RNFL (p = 0.006), and papillo-macular bundle-RNFL (p = 0.009). No association was found between OCT, MRI, and cognitive changes. Brain volume, cognitive functions, and RNFL are continuous measures of different neurodegenerative aspects. BICAMS and OCT have low costs and can be easily used in clinical practice to monitor neurodegeneration.
Evaluation of Retinal Changes in Progressive Supranuclear Palsy and Parkinson Disease.
Gulmez Sevim, Duygu; Unlu, Metin; Gultekin, Murat; Karaca, Cagatay; Mirza, Meral; Mirza, Galip Ertugrul
2018-06-01
Differentiating Parkinson disease (PD) from progressive supranuclear palsy (PSP) can be challenging early in the clinical course. The aim of our study was to see if specific retinal changes could serve as a distinguishing feature. We used spectral domain optical coherence tomography (SD-OCT) with automatic segmentation to measure peripapillary nerve fiber layer thickness and the thickness and volume of retinal layers at the macula. Thicknesses of superior peripapillary retinal nerve fiber layer (pRNFL), macular ganglion cell layer, inner plexiform layer, inner nuclear layer, and macular volume were more affected in PSP compared with PD (P < 0.05). Thicker inferotemporal pRNFL and lower macular volume were detected in levodopa users compared with nonusers in patients with PD. PD and PSP are associated with distinct changes in retinal morphology, which can be assessed with SD-OCT.
Mastropasqua, Rodolfo; Borrelli, Enrico; Agnifili, Luca; Toto, Lisa; Di Antonio, Luca; Senatore, Alfonso; Palmieri, Michele; D'Uffizi, Alessandro; Carpineto, Paolo
2017-01-01
To investigate radial peripapillary capillary (RPC) network in patients affected by retinitis pigmentosa (RP). Eleven patients (22 eyes) with previous diagnosis of RP and 16 age-matched healthy subjects (16 eyes) were enrolled. The diagnosis of RP was made based on both clinical features and electrophysiological examination. All patients underwent a complete ophthalmologic examination, including optical coherence tomography angiography and visual field (VF). The primary outcomes were the RPC vessel density in the peripapillary and disk areas; the secondary outcomes were the peripapillary retinal nerve fiber layer (RNFL) thickness and the mean defect at VF. A total of 19 eyes of 11 RP patients (5 males, 6 females) and 16 eyes of 16 healthy subjects (10 males, 6 females) were included for the analysis. RPC vessel density in the disk area was 46.5 ± 7.1% in the RP group and 45.4 ± 10.6% in the control group ( p = 0.754). RPC vessel density in the peripapillary area was significantly reduced in the RP group after the comparison with the control group (52.5 ± 5.0 and 57.2 ± 5.1%, respectively, p = 0.011). RNFL thickness was 85.9 ± 20.4 μm in the RP group and 104.0 ± 6.4 μm in the control group ( p = 0.002). RPC vessel density was significantly correlated with RNFL thickness values in RP patients, both in the disk and in the peripapillary area (Rho = 0.599 and p = 0.007 in the disk area, Rho = 0.665 and p = 0.002 in the peripapillary area, respectively). We showed that density of RPC is reduced in these patients in the peripapillary area. Moreover, the RPC vessel density correlates with the RNFL thickness.
Visual Structure and Function in Collision Sport Athletes.
Leong, Danielle; Morettin, Christina; Messner, Leonard V; Steinmetz, Robert J; Pang, Yi; Galetta, Steven L; Balcer, Laura J
2017-09-06
Vision-based measures have been shown to be useful markers in multiple sclerosis (MS), Alzheimer and Parkinson disease. Therefore, these testing paradigms may have applications to populations explaining repetitive head trauma that has been associated with long-term neurodegenerative sequelae. We investigated retinal structure and visual function in professional collision sport athletes compared to age- and race-matched control participants. In this cross-sectional study, participants underwent spectral-domain optical coherence tomography (OCT) measurements of peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell complex (GCC = ganglion cell + inner plexiform layers) thickness. High-contrast visual acuity (100% level), low-contrast letter acuity (LCLA) (1.25% and 2.5% levels), and King-Devick Test of rapid number naming performance were administered. Vision-specific quality of life (QOL) measures were assessed. Among 46 collision sport athletes (boxing, n = 14; football, n = 29; ice hockey, n = 3) and 104 control participants, average RNFL thickness was a significant predictor of athlete vs control status with athletes demonstrating 4.8-μm of thinning compared to controls (P = 0.01, generalized estimating equation [GEE] models accounting for age and within-subject, intereye correlations). Athlete vs control status was not a predictor of RNFL thickness for the subgroup of football players in this cohort (P = 0.60). Binocular (P = 0.001) and monocular (P = 0.02) LCLA at 2.5% contrast and vision-specific QOL (P = 0.04) were significant predictors of athlete vs control status (GEE models accounting for age and within-subject, intereye correlations). Rapid number naming performance times were not significantly different between the control and athlete groups. This study showed that retinal axonal and neuronal loss is present among collision sport athletes, with most notable differences seen in boxers. These findings are accompanied by reductions in visual function and QOL, similar to patterns observed in multiple sclerosis, Alzheimer and Parkinson diseases. Vision-based changes associated with head trauma exposure that have the potential to be detected in vivo represent a unique opportunity for further study to determine if these changes in collision sport athletes are predictive of future neurodegeneration.
Yu, Marco; Lin, Chen; Weinreb, Robert N; Lai, Gilda; Chiu, Vivian; Leung, Christopher Kai-Shun
2016-06-01
To investigate whether progressive retinal nerve fiber layer (RNFL) thinning is predictive of progressive visual field (VF) loss in glaucoma. Prospective study. A total of 139 primary open-angle glaucoma patients (240 eyes) followed up for ≥5 years. Retinal nerve fiber layer imaging and VF testing were performed at ∼4-month intervals. Progressive RNFL thinning was determined by event analysis (Guided Progression Analysis [GPA]) and trend analysis (Trend-based Progression Analysis [TPA]) of serial registered RNFL thickness maps. VF progression was detected according to the Early Manifest Glaucoma Trial (EMGT) ("likely progression") and pointwise linear regression (PLR) criteria (≥3 contiguous locations with sensitivity change <0 decibels [dB]/year at P < 0.01). Hazard ratios (HRs) for predicting VF progression were calculated by Cox proportional hazard modeling with progressive RNFL thinning as a time-dependent covariate. The specificity of GPA/TPA for detection of RNFL changes was determined by the proportion of eyes with significant RNFL thinning/thickening in 25 normal subjects followed weekly for 8 consecutive weeks and the proportion with significant RNFL thickening in the glaucoma group. The HRs of VF progression. A total of 65 (27.1%) and 117 eyes (48.8%) had progressive RNFL thinning based on GPA and TPA, respectively, and 30 (12.5%) and 39 eyes (16.3%) had VF progression per the EMGT and PLR criteria, respectively, during follow-up. Eyes with progressive RNFL thinning had lower VF survival estimates and a faster decline of visual field index than eyes without. Progressive RNFL thinning predicted the development of VF progression with HRs of 8.44 (95% confidence interval, 3.30-21.61) (EMGT criteria) and 5.11 (2.51-10.42) (PLR criteria) for TPA and 3.95 (1.74-8.93) (EMGT criteria) and 3.81 (1.83-7.92) (PLR criteria) for GPA after controlling for baseline covariates. The specificities of GPA and TPA were 100% (83.4%-100.0%) in the normal group and 81.7% (76.2%-86.4%) and 84.2% (78.9%-88.6%), respectively, in the glaucoma group. Progressive RNFL thinning determined by GPA and TPA is predictive of detectable functional decline in glaucoma. This finding underscores the significance of detecting progressive RNFL thinning and its relevance to initiate or augment treatment for glaucoma patients. Regulatory authorities may consider progressive RNFL thinning as an outcome measure in clinical trials for evaluation of glaucoma treatment. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Retinal Tissue Thickness is Reduced in Diabetic Peripheral Neuropathy.
Srinivasan, Sangeetha; Pritchard, Nicola; Vagenas, Dimitrios; Edwards, Katie; Sampson, Geoff P; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2016-10-01
To investigate the relationship between diabetic peripheral neuropathy (DPN) and retinal tissue thickness. Full retinal thickness in the central retinal, parafoveal, and perifoveal zones and thickness of the ganglion cell complex and retinal nerve fiber layer (RNFL) were assessed in 193 individuals (84 with type 1 diabetes, 67 with type 2 diabetes, and 42 healthy controls) using spectral domain optical coherence tomography. Among those with diabetes, 44 had neuropathy defined using a modified neuropathy disability score recorded on a 0-10 scale. Multiple regression analysis was performed to investigate the relationship between diabetic neuropathy and retinal tissue thickness, adjusted for the presence of diabetic retinopathy (DR), age, sex, duration of diabetes, and HbA 1c levels. In individuals with diabetes, perifoveal thickness was inversely related to the severity of neuropathy (p < 0.05), when adjusted for age, sex, duration of diabetes, and HbA 1c levels. DR was associated with reduced thickness in parafovea (p < 0.01). The RNFL was thinner in individuals with greater degrees of neuropathy (p < 0.04). DPN is associated with structural compromise involving several retinal layers. This compromise may represent a threat to visual integrity and therefore warrants examination of functional correlates.
Glaucoma Structural and Functional Progression in American and Korean Cohorts
Kostanyan, Tigran; Sung, Kyung Rim; Schuman, Joel S.; Ling, Yun; Lucy, Katie A.; Bilonick, Richard A.; Ishikawa, Hiroshi; Kagemann, Larry; Lee, Jin Y.; Wollstein, Gadi
2016-01-01
Objective To compare the rate of glaucoma structural and functional progression in American and Korean cohorts. Design Retrospective longitudinal study. Participants 313 eyes from 189 glaucoma and glaucoma suspects, followed for an average of 38 months. Methods All subjects were examined semiannually with visual field (VF) testing and spectral-domain optical coherence tomography. All subjects had ≥5 reliable visits. Main Outcome Measurements The rates of change of retinal nerve fiber layer (RNFL) thickness, cup-to-disc (C/D) ratios, and VF mean deviation (MD) were compared between the cohorts. Variables affecting the rate of change for each parameter were determined, including ethnicity, refraction, baseline age and severity, disease subtype (high vs. normal tension glaucoma), clinical diagnosis (glaucoma vs. glaucoma suspect), and the interactions between variables. Results The Korean cohort was predominantly normal tension glaucoma, while the American cohort was high tension glaucoma. Cohorts had similar VF parameters at baseline, but the Korean eyes had significantly thinner mean RNFL and larger cups. Korean glaucoma eyes showed a faster thinning of mean RNFL (mean: −0.71 vs. −0.24μm/year, p<0.01). There was no detectable difference in the rate of change between the glaucoma cohorts for C/D ratios and VF MD and for all parameters in glaucoma suspect eyes. Different combinations of the tested variables significantly impacted the rate of change. Conclusion Ethnicity, baseline severity, disease subtype, and clinical diagnosis should be considered when comparing glaucoma progression studies. PMID:26778345
Saini, VK; Gupta, Saroj; Sharma, Anjali
2014-01-01
ABSTRACT Purpose: To evaluate the normative data of macular thickness and retinal nerve fiber layer thickness (RNFL) among normal subjects using spectral domain optical coherence tomography (OCT). Materials and methods: Normal subjects presenting to a tertiary medical hospital were included in the study. All patient underwent clinical examination followed by study of macular thickness and RN FL thick ness by spectral domain Topc on OCT. The data was collected and analyzed for variations in gender and age. The data was also compared with available literature. Results: Total numbers of patients enrolled in the study were 154 (308 eyes). Numbers of males were 79 (158 eyes) and numbers of females were 75 (150 eyes). The mean age among males was 42.67 ± 12.15 years and mean age among females was 42.88 ± 11.73 years. Overall the mean mac ular thickness (central 1 mm zone) with SD - OCT was 241.75 ± 17.3 microns. The mean macular volume was 7.6 cu. mm ± 0.33. On analysis of the RNFL thickness, we observed that the RNFL was thickest in the inferior quadrant (138.58) followed by superior (122.30) nasal (116.32) and temporal quadrant (73.04). Gender-wise comparison of the data revealed no statistically significant difference for age, macular thickness parameters, volume and RFNL values except outer temporal thickness among males and females. No age-related difference was noted in the above parameters. On comparison with available norma tive data from India and elsewhere, we found significant variations with different machines. Conclusion: The study is the first to provide normative data using SD-OCT from central India. The data from spectral domain OCT correlated well with the values obtained from similar studies with SD - OCT. Values obtained from time domain OCT machines are different and are not comparable. How to cite this article: Agarwal P, Saini VK, Gupta S, Sharma A. Evaluation of Central Macular Thickness and Retinal Nerve Fiber Layer Thickness using Spectral Domain Optical Coherence Tomography in a Tertiary Care Hospital. J Curr Glaucoma Pract 2014;8(2):75-81. PMID:26997813
Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis
Armstrong, James J.; Pintwala, Robert; Hutnik, Cindy
2018-01-01
Purpose Early detection, monitoring and understanding of changes in the retina are central to the diagnosis of glaucomatous optic neuropathy, and vital to reduce visual loss from this progressive condition. The main objective of this investigation was to compare glaucoma diagnostic accuracy of commercially available optical coherence tomography (OCT) devices (Zeiss Stratus, Zeiss Cirrus, Heidelberg Spectralis and Optovue RTVue, and Topcon 3D-OCT). Patients 16,104 glaucomatous and 11,543 normal eyes reported in 150 studies. Methods Between Jan. 2017 and Feb 2017, MEDLINE®, EMBASE®, CINAHL®, Cochrane Library®, Web of Science®, and BIOSIS® were searched for studies assessing glaucoma diagnostic accuracy of the aforementioned OCT devices. Meta-analysis was performed pooling area under the receiver operating characteristic curve (AUROC) estimates for all devices, stratified by OCT type (RNFL, macula), and area imaged. Results 150 studies with 16,104 glaucomatous and 11,543 normal control eyes were included. Key findings: AUROC of glaucoma diagnosis for RNFL average for all glaucoma patients was 0.897 (0.887–0.906, n = 16,782 patient eyes), for macula ganglion cell complex (GCC) was 0.885 (0.869–0.901, n = 4841 eyes), for macula ganglion cell inner plexiform layer (GCIPL) was 0.858 (0.835–0.880, n = 4211 eyes), and for total macular thickness was 0.795 (0.754–0.834, n = 1063 eyes). Conclusion The classification capability was similar across all 5 OCT devices. More diagnostically favorable AUROCs were demonstrated in patients with increased glaucoma severity. Diagnostic accuracy of RNFL and segmented macular regions (GCIPL, GCC) scans were similar and higher than total macular thickness. This study provides a synthesis of contemporary evidence with features of robust inclusion criteria and large sample size. These findings may provide guidance to clinicians when navigating this rapidly evolving diagnostic area characterized by numerous options. PMID:29300765
Ara, Mirian; Pajarin, Ana B.
2015-01-01
Objective. To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. Methods. One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. Results. ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. Conclusions. The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression. PMID:26185762
Nieves-Moreno, María; Martínez-de-la-Casa, José M; Morales-Fernández, Laura; Sánchez-Jean, Rubén; Sáenz-Francés, Federico; García-Feijoó, Julián
2018-01-01
To examine differences in individual retinal layer thicknesses measured by spectral domain optical coherence tomography (SD-OCT) (Spectralis®) produced with age and according to sex. Cross-sectional, observational study. The study was conducted in 297 eyes of 297 healthy subjects aged 18 to 87 years. In one randomly selected eye of each participant the volume and mean thicknesses of the different macular layers were measured by SD-OCT using the instrument's macular segmentation software. Volume and mean thickness of macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), retinal pigmentary epithelium (RPE) and photoreceptor layer (PR). Retinal thickness was reduced by 0.24 μm for every one year of age. Age adjusted linear regression analysis revealed mean GCL, IPL, ONL and PR thickness reductions and a mean OPL thickness increase with age. Women had significantly lower mean GCL, IPL, INL, ONL and PR thicknesses and volumes and a significantly greater mRNFL volume than men. The thickness of most retinal layers varies both with age and according to sex. Longitudinal studies are needed to determine the rate of layer thinning produced with age.
Hirasawa, Kazunori; Shoji, Nobuyuki
2017-01-01
To evaluate the influence of corneal power on circumpapillary retinal nerve fiber layer (cpRNFL) and optic nerve head (ONH) measurements by spectral-domain optical coherence tomography (SD-OCT). Twenty-five eyes of 25 healthy participants (mean age 23.6±3.6y) were imaged by SD-OCT using horizontal raster scans. Disposable soft contact lenses of different powers (from -11 to +5 diopters including 0 diopter) were worn to induce 2-diopter changes in corneal power. Differences in the cpRNFL and ONH measurements per diopter of change in corneal power were analyzed. As corneal power increased by 1 diopter, total and quadrant cpRNFL thicknesses, except for the nasal sector, decreased by --0.19 to -0.32 µm ( P <0.01). Furthermore, the disc, cup, and rim areas decreased by -0.017, -0.007, and -0.015 mm 2 , respectively ( P <0.001); the cup and rim volumes decreased by -0.0013 and -0.006 mm 3 , respectively ( P <0.01); and the vertical and horizontal disc diameters decreased by -0.006 and -0.007 mm, respectively ( P <0.001). For more precise OCT imaging, the ocular magnification should be corrected by considering both the axial length and corneal power. However, the effect of corneal power changes on cpRNFL thickness and ONH topography are small when compare with those of the axial length.
Lim, Michele C; Tanimoto, Suzana A; Furlani, Bruno A; Lum, Brent; Pinto, Luciano M; Eliason, David; Prata, Tiago S; Brandt, James D; Morse, Lawrence S; Park, Susanna S; Melo, Luiz A S
2009-07-01
To determine if panretinal photocoagulation (PRP) alters retinal nerve fiber layer (RNFL) thickness and optic nerve appearance. Patients with diabetes who did and did not undergo PRP and nondiabetic control subjects were enrolled in a prospective study. Participants underwent optical coherence tomography of the peripapillary retina and optic nerve. Stereoscopic optic nerve photographs were graded in a masked fashion. Ninety-four eyes of 48 healthy individuals, 89 eyes of 55 diabetic patients who did not undergo PRP, and 37 eyes of 24 subjects with diabetes who underwent PRP were included in this study. Eyes that had been treated with PRP had thinner peripapillary RNFL compared with the other groups; this was statistically significantly different in the inferior (P = .004) and nasal (P = .003) regions. Optic nerve cupping did not increase with severity of disease classification, but the proportion of optic nerves graded as suspicious for glaucoma or as having nonglaucomatous optic neuropathy did (P = .008). These grading categories were associated with thinner RNFL measurements. Diabetic eyes that have been treated with PRP have thinner RNFL than nondiabetic eyes. Optic nerves in eyes treated with PRP are more likely to be graded as abnormal, but their appearance is not necessarily glaucomatous and may be related to thinning of the RNFL.
Springelkamp, Henriët; Lee, Kyungmoo; Wolfs, Roger C W; Buitendijk, Gabriëlle H S; Ramdas, Wishal D; Hofman, Albert; Vingerling, Johannes R; Klaver, Caroline C W; Abràmoff, Michael D; Jansonius, Nomdo M
2014-11-20
We determined the glaucoma screening performance of regional optical coherence tomography (OCT) layer thickness measurements in the peripapillary and macular region, in a population-based setting. Subjects (n = 1224) in the Rotterdam Study underwent visual field testing (Humphrey Field Analyzer) and OCT of the macula and optic nerve head (Topcon 3-D OCT-1000). We determined the mean thicknesses of the retinal nerve fiber layer (RNFL), retinal ganglion cell layer (RGCL), and inner plexiform layer for regions-of-interest; thus, defining a series of OCT parameters, using the Iowa Reference Algorithms. Reference standard was the presence of glaucomatous visual field loss (GVFL); controls were subjects without GVFL, an intraocular pressure (IOP) of 21 mm Hg or less, and no positive family history for glaucoma. We calculated the area under the receiver operating characteristics curve (AUCs) and the sensitivity at 97.5% specificity for each parameter. After excluding 23 subjects with an IOP > 21 mm Hg and 73 subjects with a positive family history for glaucoma, there were 1087 controls and 41 glaucoma cases. Mean RGCL thickness in the inferior half of the macular region showed the highest AUC (0.85; 95% confidence interval [CI] 0.77-0.92) and sensitivity (53.7%; 95% CI, 38.7-68.0%). The mean thickness of the peripapillary RNFL had an AUC of 0.77 (95% CI, 0.69-0.85) and a sensitivity of 24.4% (95% CI, 13.7-39.5%). Macular RGCL loss is at least as common as peripapillary RNFL abnormalities in population-based glaucoma cases. Screening for glaucoma using OCT-derived regional thickness identifies approximately half of those cases of glaucoma as diagnosed by perimetry. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Mavrommatis, Maria A; Wu, Zhichao; Naegele, Saskia I; Nunez, Jason; De Moraes, Carlos; Ritch, Robert; Hood, Donald C
2018-02-01
To examine the structure-function relationship in glaucoma between deep defects on visual fields (VF) and deep losses in the circumpapillary retinal nerve fiber layer (cpRNFL) on optical coherence tomography (OCT) circle scans. Thirty two glaucomatous eyes with deep VF defects, as defined by at least one test location worse than ≤ -15 dB on the 10-2 and/or 24-2 VF pattern deviation (PD) plots, were included from 87 eyes with "early" glaucoma (i.e., 24-2 mean deviation better than -6 dB). Using the location of the deep VF points and a schematic model, the location of local damage on an OCT circle scan was predicted. The thinnest location of cpRNFL (i.e., deepest loss) was also determined. In 19 of 32 eyes, a region of complete or near complete cpRNFL loss was observed. All 19 of these had deep VF defects on the 24-2 and/or 10-2. All of the 32 eyes with deep VF defects had abnormal cpRNFL regions (red, 1%) and all but 2 had a region of cpRNFL thickness <21 μm. The midpoint of the VF defect and the location of deepest cpRNFL had a 95% limit of agreement within approximately two-thirds of a clock-hour (or 30°) sector (between -22.1° to 25.2°). Individual fovea-to-disc angle (FtoDa) adjustment improved agreement in one eye with an extreme FtoDa. Although studies relating local structural (OCT) and functional (VF) measures typically show poor to moderate correlations, there is good qualitative agreement between the location of deep cpRNFL loss and deep defects on VFs.
The effect of parental factors in children with large cup-to-disc ratios.
Park, Hae-Young Lopilly; Ha, Min Ji; Shin, Sun Young
2017-01-01
To investigate large cup-to-disc ratios (CDR) in children and to determine the relationship between parental CDR and clinical characteristics associated with glaucoma. Two hundred thirty six children aged 6 to 12 years with CDR ≥ 0.6 were enrolled in this study. Subjects were classified into two groups based on parental CDR: disc suspect children with disc suspect (CDR ≥0.6) parents and disc suspect children without disc suspect parents. Ocular variables were compared between the two groups. Of the 236 disc suspect children, 100 (42.4%) had at least one disc suspect parent. Intraocular pressure (IOP) was higher in disc suspect children with disc suspect parents (16.52±2.66 mmHg) than in disc suspect children without disc suspect parents (14.38±2.30 mmHg, p = 0.023). In the group with disc suspect parents, vertical CDR significantly correlated with IOP (R = -0.325, p = 0.001), average retinal nerve fiber layer (RNFL) thickness (R = -0.319, p = 0.001), rim area (R = -0.740, p = 0.001), and cup volume (R = 0.499, p = 0.001). However, spherical equivalent (R = 0.333, p = 0.001), AL (R = -0.223, p = 0.009), and disc area (R = 0.325, p = 0.001) significantly correlated with vertical CDR in disc suspect children without disc suspect parents, in contrast to those with disc suspect parents. Larger vertical CDR was associated with the presence of disc suspect parents (p = 0.001), larger disc area (p = 0.001), thinner rim area (p = 0.001), larger average CDR (p = 0.001), and larger cup volume (p = 0.021). Family history of large CDR was a significant factor associated with large vertical CDR in children. In children with disc suspect parents, there were significant correlations between IOP and average RNFL thickness and vertical CDR.
Histogram Matching Extends Acceptable Signal Strength Range on Optical Coherence Tomography Images
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Sigal, Ian A.; Kagemann, Larry; Schuman, Joel S.
2015-01-01
Purpose. We minimized the influence of image quality variability, as measured by signal strength (SS), on optical coherence tomography (OCT) thickness measurements using the histogram matching (HM) method. Methods. We scanned 12 eyes from 12 healthy subjects with the Cirrus HD-OCT device to obtain a series of OCT images with a wide range of SS (maximal range, 1–10) at the same visit. For each eye, the histogram of an image with the highest SS (best image quality) was set as the reference. We applied HM to the images with lower SS by shaping the input histogram into the reference histogram. Retinal nerve fiber layer (RNFL) thickness was automatically measured before and after HM processing (defined as original and HM measurements), and compared to the device output (device measurements). Nonlinear mixed effects models were used to analyze the relationship between RNFL thickness and SS. In addition, the lowest tolerable SSs, which gave the RNFL thickness within the variability margin of manufacturer recommended SS range (6–10), were determined for device, original, and HM measurements. Results. The HM measurements showed less variability across a wide range of image quality than the original and device measurements (slope = 1.17 vs. 4.89 and 1.72 μm/SS, respectively). The lowest tolerable SS was successfully reduced to 4.5 after HM processing. Conclusions. The HM method successfully extended the acceptable SS range on OCT images. This would qualify more OCT images with low SS for clinical assessment, broadening the OCT application to a wider range of subjects. PMID:26066749
Yamashita, Takehiro; Asaoka, Ryo; Kii, Yuya; Terasaki, Hiroto; Murata, Hiroshi; Sakamoto, Taiji
2017-01-01
The location of the peaks of the circumpapillary retinal nerve fiber layer (cpRNFL) thickness is affected by several ocular parameters. In this study, we have generated equations that can determine the peaks of the cpRNFL. This study was a prospective, observational, cross sectional study of 118 healthy right eyes. The axial length, optic disc tilt, superiortemporal (ST)- and inferiortemporal (IT)-peaks of the cpRNFL thickness, and angles of the ST and IT retinal arteries (RA) and veins (RV) were determined. The correlations between the location of the ST- and IT-peaks and ocular structural parameters and the sex, body height and weight were calculated. The best fit equations to generate the location of the ST/IT-peaks were determined using corrected-Akaike Information Criteria. The location of the ST-peak was 0.72+(0.40 x ST-RA)+(0.27 x ST-RV)+(0.14 x height)-(0.47 x papillo-macular-position)-(0.11 x disc tilt) with a coefficient of correlation of 0.61 (P<0.0001). The location of the IT-peak was 21.88+(0.53 x IT-RA)+(0.15 x IT-RV)+(0.041 x corneal thickness)-(1.00 x axial length) with a coefficient of correlation of 0.59 (P<0.0001). The location of ST/IT peaks is determined by different parameters of the ocular structure. These equations allow clinicians to obtain an accurate location of the peaks for a more accurate diagnosis of glaucoma.
Bertsch-Gout, Marcel; Loeb, Richard; Finch, Ashley K; Javed, Adil; Bernard, Jacqueline
2018-01-15
There is a need for biomarkers that can classify optic neuritis (ON) attacks as belonging to either neuromyelitis optica spectrum disorder with optic neuritis (NMOSD-ON) or relapsing remitting multiple sclerosis with optic neuritis (MS-ON). This study uses spectral domain optical coherence tomography (SD-OCT) data to perform a preliminary contrast between NMOSD-ON and MS-ON by analyzing peripapillary retinal nerve fiber layer and intra-macular layer patterns of injury. In this cross-sectional study, we used SD-OCT to obtain peripapillary retinal nerve fiber layer and intra-macular layer data for 26 NMOSD-ON, 25 MS-ON, and 26 healthy control (HC) age-matched eyes. Additionally, sub-comparisons compared 11 NMOSD-ON eyes that were seronegative for IgG antibodies against aquaporin 4 (NMOSD-ON (-)) and 16 NMOSD-ON eyes that were seropositive (NMOSD-ON (+)) to age-matched MS-ON eyes. Layer thicknesses were assessed using an automated algorithm and were then statistically compared using generalized estimating equations to account for inter-eye correlations. Selective thinning was found in the pRNFL, mRNFL, and GCL in NMOSD-ON compared to MS-ON. Thinning in the pRNFL nasal sector was found to persist in both NMOSD-ON (-) (P=0.017) and NMOSD-ON (+) (P=0.021) compared to MS-ON. Thinning in the mRNFL temporal sector was found to persist in NMOSD-ON (+) compared to MS-ON. Diffuse thinning was found in the pRNFL, mRNFL, GCL and IPL in NMOSD-ON compared to HC, and while diffuse thinning was also found in the GCL and IPL in MS-ON compared to HC, selective thinning was found in the pRNFL and mRNFL. The nasal region of the pRNFL may be capable of distinguishing between NMOSD-ON and MS-ON regardless of antibody status. Additionally, NMOSD-ON may cause more profound nasal axonal and inferior arcuate neuronal degeneration compared to MS-ON. Copyright © 2017 Elsevier B.V. All rights reserved.
2012-01-01
Bakground To evaluate objectively the anatomical and functional changes of optic nerve in eyes with primary open angle glaucoma (POAG) by the joint use of optical coherence tomography (OCT) and multifocal visual evoked potentials (mfVEP). Methods 29 eyes with open angle glaucoma and visual field defects, as well as 20 eyes of 10 age-matched control normal subjects were tested. All participants underwent a complete ophthalmological examination. Moreover, Humphrey visual field test, OCT examination and recording of mfVEP were performed. Amplitude and implicit time of mfVEP, as well as RNFL thickness were measured. Differences in density components of mfVEP and in RNFL thickness among POAG eyes and control eyes were examined using Student’s t-test. Results In glaucomatous eyes the mean Retinal Response Density (RRD) was lower than normal in ring 1, 2 and 3 of mfVEP (p < 0.0001). Specifically the mean amplitude of mfVEP in POAG eyes was estimated at 34.2 ± 17.6 nV/deg2, 6.9 ± 4.8 nV/deg2 and 2.6 ± 1.6 nV/deg2 in rings 1, 2 and 3 respectively. In contrast the mean implicit time was similar to control eyes. In addition, the mean RNFL thickness in POAG eyes was estimated at 76.8 ± 26.6 μm in the superior area, 52.1 ± 16.3 μm in the temporal area, 75.9 ± 32.5 μm in the inferior area and 58.6 ± 19.4 μm in the nasal area. There was a statistically significant difference in RNFL thickness in all peripapillary areas (p < 0.0001) between POAG eyes and controls, with superior and inferior area to present the highest decrease. Conclusions Our study shows that, although Standard Automatic Perimetry is the gold standard to evaluate glaucomatous neuropathy, the joint use of mfVEP and OCT could be useful in better monitoring glaucoma progression. PMID:22856337
Thinner retinal layers are associated with changes in the visual pathway: A population-based study.
Mutlu, Unal; Ikram, Mohammad K; Roshchupkin, Gennady V; Bonnemaijer, Pieter W M; Colijn, Johanna M; Vingerling, Johannes R; Niessen, Wiro J; Ikram, Mohammad A; Klaver, Caroline C W; Vernooij, Meike W
2018-06-23
Increasing evidence shows that thinner retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL), assessed on optical coherence tomography (OCT), are reflecting global brain atrophy. Yet, little is known on the relation of these layers with specific brain regions. Using voxel-based analysis, we aimed to unravel specific brain regions associated with these retinal layers. We included 2,235 persons (mean age: 67.3 years, 55% women) from the Rotterdam Study (2007-2012) who had gradable retinal OCT images and brain magnetic resonance imaging (MRI) scans, including diffusion tensor (DT) imaging. Thicknesses of peripapillary RNFL and perimacular GCL were measured using an automated segmentation algorithm. Voxel-based morphometry protocols were applied to process DT-MRI data. We investigated the association between retinal layer thickness with voxel-wise gray matter density and white matter microstructure by performing linear regression models. We found that thinner RNFL and GCL were associated with lower gray matter density in the visual cortex, and with lower fractional anisotropy and higher mean diffusivity in white matter tracts that are part of the optic radiation. Furthermore, thinner GCL was associated with lower gray matter density of the thalamus. Thinner RNFL and GCL are associated with gray and white matter changes in the visual pathway suggesting that retinal thinning on OCT may be specifically associated with changes in the visual pathway rather than with changes in the global brain. These findings may serve as a basis for understanding visual symptoms in elderly patients, patients with Alzheimer's disease, or patients with posterior cortical atrophy. © 2018 Wiley Periodicals, Inc.
Garcia-Martin, Elena; Rodriguez-Mena, Diego; Dolz, Isabel; Almarcegui, Carmen; Gil-Arribas, Laura; Bambo, Maria P; Larrosa, Jose M; Polo, Vicente; Pablo, Luis E
2013-08-01
To evaluate the effect of uncomplicated cataract phacoemulsification on the measurements of visual evoked potentials (VEP), pattern electroretinogram (PERG), and macular and retinal nerve fiber layer (RNFL) using 2 spectral-domain optical coherence tomography (OCT) instruments, the Cirrus OCT (Carl Zeiss Meditech) and Spectralis OCT (Heidelberg Engineering), in patients with retinitis pigmentosa (RP), and to assess the reliability of the OCT measurements before and after cataract surgery. Observational cross-sectional study. Thirty-five eyes of 35 patients with RP (20 men and 15 women, 45-66 years) who underwent cataract phacoemulsification were studied. At 1 month before and 1 month after surgery, visual acuity, VEP, PERG, and 3 repetitions of scans using the RNFL and macular analysis protocols of the Cirrus and Spectralis OCT instruments were performed. The differences in measurements between the 2 visits were analyzed. Repeatability of OCT measurements was evaluated by calculating the coefficients of variation. VEP amplitude, RNFL thicknesses provided by Cirrus and Spectralis, and macular measurements provided by Cirrus OCT differed between the 2 visits. VEP latency, PERG measurements, and macular thicknesses provided by the Spectralis OCT before surgery did not differ significantly from those after surgery. The OCT repeatability was better after surgery, with lower coefficients of variation for scans performed after surgical removal of the cataract. The nuclear, cortical, and posterior subcapsular types of cataracts did not show different repeatability. The presence of cataracts affects VEP amplitude, RNFL, and macular measurements performed with OCT in eyes with RP. Image repeatability significantly improves after cataract phacoemulsification. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Antony, Bhavna J.; Abràmoff, Michael D.; Lee, Kyungmoo; Sonkova, Pavlina; Gupta, Priya; Kwon, Young; Niemeijer, Meindert; Hu, Zhihong; Garvin, Mona K.
2010-03-01
Optical coherence tomography (OCT), being a noninvasive imaging modality, has begun to find vast use in the diagnosis and management of ocular diseases such as glaucoma, where the retinal nerve fiber layer (RNFL) has been known to thin. Furthermore, the recent availability of the considerably larger volumetric data with spectral-domain OCT has increased the need for new processing techniques. In this paper, we present an automated 3-D graph-theoretic approach for the segmentation of 7 surfaces (6 layers) of the retina from 3-D spectral-domain OCT images centered on the optic nerve head (ONH). The multiple surfaces are detected simultaneously through the computation of a minimum-cost closed set in a vertex-weighted graph constructed using edge/regional information, and subject to a priori determined varying surface interaction and smoothness constraints. The method also addresses the challenges posed by presence of the large blood vessels and the optic disc. The algorithm was compared to the average manual tracings of two observers on a total of 15 volumetric scans, and the border positioning error was found to be 7.25 +/- 1.08 μm and 8.94 +/- 3.76 μm for the normal and glaucomatous eyes, respectively. The RNFL thickness was also computed for 26 normal and 70 glaucomatous scans where the glaucomatous eyes showed a significant thinning (p < 0.01, mean thickness 73.7 +/- 32.7 μm in normal eyes versus 60.4 +/- 25.2 μm in glaucomatous eyes).
Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Saunders, Luke J.; Suh, Min Hee; Wu, Zhichao; Manalastas, Patricia Isabel C.; Akagi, Tadamichi; Medeiros, Felipe A.; Weinreb, Robert N.
2017-01-01
Purpose To compare hemifield differences in the vessel density of the optic nerve head and macula in open-angle glaucoma (OAG) eyes with visual field (VF) defect confined to one hemifield using optical coherence tomography angiography (OCT-A). Design Cross-sectional study. Participants Fifty-eight eyes of 58 glaucoma patients with VF loss confined to a single hemifield, and 28 healthy eyes. Methods Retinal vasculature information was summarized as circumpapillary vessel density (cpVD) and perifoveal vessel density (pfVD). Circumpapillary retinal nerve fiber layer (cpRNFL) and macular ganglion cell complex (mGCC) thickness were also calculated using spectral domain OCT. Paired and unpaired t-tests were utilized to evaluate differences between the perimetrically affected and intact hemiretinae and healthy hemiretinae. Linear regression analyses were performed to evaluate the associations between VF measures with vascular and structural measurements. Main Outcome Measures Total and hemispheric cpVD, pfVD, cpRNFL, mGCC and mean sensitivity (MS). Results Mean cpVD and pfVD in the intact hemiretinae of OAG eyes (59.0% and 51.1%) were higher than the affected hemiretinae (54.7% and 48.3%; p<0.001) but lower than healthy eyes (62.4% and 53.8%; p<0.001). Similar results were noted with cpRNFL and mGCC thickness measurements (p<0.05 for both). The strongest associations between MS in the affected hemifields were found for cpVD (r = 0.707), followed by pfVD (r = 0.615), cpRNFL (r = 0.496) and mGCC (r = 0.482) in the corresponding hemiretinae (p<0.001 for all). Moreover the correlations in the intact hemifields between MS with cpVD and pfVD were found to be higher (r = 0.450 and 0.403) than the correlations between MS and cpRNFL and mGCC thickness measurements (r = 0.340 and 0.290; all p-values <0.05 for all). Conclusions Reduced peripapillary and macular vessel density was detectable in the perimetrically intact hemiretinae of glaucoma eyes with a single-hemifield defect. Moreover vessel density attenuation in both affected and intact hemiretinae was associated with the extent of VF damage in the corresponding hemifields. OCT-A potentially shows promise for identifying glaucomatous damage before focal VF defects are detectable. PMID:28196732
Patel, Aarti; Purohit, Ravi; Lee, Helena; Sheth, Viral; Maconachie, Gail; Papageorgiou, Eleni; McLean, Rebecca J; Gottlob, Irene; Proudlock, Frank A
2016-10-01
To determine feasibility of optic nerve head (ONH) imaging and to characterize ONH development in full-term infants without sedation using handheld spectral-domain optical coherence tomography (SD OCT). Prospective cross-sectional study. Three hundred fifty-two children aged between 1 day and 13 years. All participants were imaged using handheld SD OCT without sedation during a single scan session. The percentage of successful scans was calculated. Interexaminer reproducibility and differences between right and left eyes were assessed using intraclass correlation coefficients (ICCs). Images were analyzed using ImageJ software. The developmental trajectories over time for ONH parameters were calculated using fractional polynomial modelling. Disc and cup diameter (expressed as distance in micrometers and visual angle in degrees), cup depth, Bruch's membrane opening-minimum rim width (BMO-MRW), retinal thickness, and retinal nerve fiber layer (RNFL; 1700 μm and 6° from the disc center). On average, 70% of participants were imaged successfully. Interexaminer reliability was excellent (ICC, >0.89) for diametric and retinal thickness parameters. Right and left eyes were similar for diametric measurements (ICC, >0.79), but more variable for nasal BMO-MRW, RNFL, and retinal thickness. The mean disc and cup diameter increase by 30% and 40%, respectively, between birth and 13 years of age when expressed as a distance measure, but remained constant (at 5°-5.5° and 2°, respectively) when expressed as a visual angle with reference to the eye nodal point. The peripapillary temporal RNFL demonstrated a marked initial decrease of nearly 35% between birth and approximately 18 months of age. This was followed by a slow increase up to 12 years of age when measured at 1700 μm from the disc center, although there was little change when measured at 6° from the disc center. We demonstrated feasibility of handheld SD OCT imaging of the ONH in full-term infants and children without anaesthesia or sedation. This is the first in vivo handheld SD OCT study to describe the development of ONH parameters during the critical early years of visual maturation. Our results provide a normative database for use in routine practice and further studies of ONH pathologic features. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Rao, Harsha L; Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2015-03-01
To evaluate the effect of typical scan score (TSS), when within the acceptable limits, on the diagnostic performance of retinal nerve fibre layer (RNFL) parameters with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in glaucoma. In a cross-sectional study, 203 eyes of 160 glaucoma patients and 140 eyes of 104 control subjects underwent RNFL imaging with the ECC protocol of SLP. TSS was used to quantify atypical birefringence pattern (ABP) images. Influence of TSS on the diagnostic ability of SLP parameters was evaluated by receiver operating characteristic (ROC) regression models after adjusting for the effect of disease severity [based on mean deviation (MD)] on standard automated perimetry). Diagnostic abilities of all RNFL parameters of SLP increased when the TSS values were higher. This effect was statistically significant for TSNIT (coefficient: 0.08, p<0.001) and inferior average parameters (coefficient: 0.06, p=0.002) but not for nerve fibre indicator (NFI, coefficient: 0.03, p=0.21). In early glaucoma (MD of -5 dB), predicted area under ROC curve (AUC) for TSNIT average parameter improved from 0.642 at a TSS of 90 to 0.845 at a TSS of 100. In advanced glaucoma (MD of -15 dB), AUC for TSNIT average improved from 0.832 at a TSS of 90 to 0.947 at 100. Diagnostic performances of TSNIT and inferior average RNFL parameters with ECC protocol of SLP were significantly influenced by TSS even when the TSS values were within the acceptable limits. Diagnostic ability of NFI was unaffected by TSS values. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics.
Kocaoglu, Omer P; Cense, Barry; Jonnal, Ravi S; Wang, Qiang; Lee, Sangyeol; Gao, Weihua; Miller, Donald T
2011-08-15
Early detection of axonal tissue loss in retinal nerve fiber layer (RNFL) is critical for effective treatment and management of diseases such as glaucoma. This study aims to evaluate the capability of ultrahigh-resolution optical coherence tomography with adaptive optics (UHR-AO-OCT) for imaging the RNFL axonal bundles (RNFBs) with 3×3×3μm(3) resolution in the eye. We used a research-grade UHR-AO-OCT system to acquire 3°×3° volumes in four normal subjects and one subject with an arcuate retinal nerve fiber layer defect (n=5; 29-62years). Cross section (B-scans) and en face (C-scan) slices extracted from the volumes were used to assess visibility and size distribution of individual RNFBs. In one subject, we reimaged the same RNFBs twice over a 7month interval and compared bundle width and thickness between the two imaging sessions. Lastly we compared images of an arcuate RNFL defect acquired with UHR-AO-OCT and commercial OCT (Heidelberg Spectralis). Individual RNFBs were distinguishable in all subjects at 3° retinal eccentricity in both cross-sectional and en face views (width: 30-50μm, thickness: 10-15μm). At 6° retinal eccentricity, RNFBs were distinguishable in three of the five subjects in both views (width: 30-45μm, thickness: 20-40μm). Width and thickness RNFB measurements taken 7months apart were strongly correlated (p<0.0005). Mean difference and standard deviation of the differences between the two measurement sessions were -0.1±4.0μm (width) and 0.3±1.5μm (thickness). UHR-AO-OCT outperformed commercial OCT in terms of clarity of the microscopic retina. To our knowledge, these are the first measurements of RNFB cross section reported in the living human eye. Copyright © 2011 Elsevier Ltd. All rights reserved.
Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics
Kocaoglu, Omer P.; Cense, Barry; Jonnal, Ravi S.; Wang, Qiang; Lee, Sangyeol; Gao, Weihua; Miller, Donald T.
2011-01-01
Early detection of axonal tissue loss in retinal nerve fiber layer (RNFL) is critical for effective treatment and management of diseases such as glaucoma. This study aims to evaluate the capability of ultrahigh-resolution optical coherence tomography with adaptive optics (UHR-AO-OCT) for imaging the RNFL axonal bundles (RNFBs) with 3×3×3 μm3 resolution in the eye. We used a research-grade UHR-AO-OCT system to acquire 3°×3° volumes in four normal subjects and one subject with an arcuate retinal nerve fiber layer defect (n=5; 29–62yrs). Cross section (B-scans) and en face (C-scan) slices extracted from the volumes were used to assess visibility and size distribution of individual RNFBs. In one subject, we reimaged the same RNFBs twice over a seven month interval and compared bundle width and thickness between the two imaging sessions. Lastly we compared images of an arcuate RNFL defect acquired with UHR-AO-OCT and commercial OCT (Heidelberg Spectralis). Individual RNFBs were distinguishable in all subjects at 3° retinal eccentricity in both cross-sectional and en face views (width: 30–50μm, thickness: 10–15μm). At 6° retinal eccentricity, RNFBs were distinguishable in three of the five subjects in both views (width: 30–45μm, thickness: 20–40μm). Width and thickness RNFB measurements taken seven months apart were strongly correlated (p<0.0005). Mean difference and standard deviation of the differences between the two measurement sessions were −0.1±4.0 μm (width) and 0.3±1.5 μm (thickness). UHR-AO-OCT outperformed commercial OCT in terms of clarity of the microscopic retina. To our knowledge, these are the first measurements of RNFB cross section reported in the living human eye. PMID:21722662
Optical Coherence Tomographic Comparison of Cuban Epidemic and Leber’s Hereditary Optic Neuropathy
Santiesteban-Freixas, Rosaralis; Pola-Alvarado, Lester; Columbie-Garbey, Yannara; Gonzalez-Quevedo, Alina; Juvier-Riesgo, Tamara; Hernandez-Echevarria, Odelaisys; Hedges, Thomas R.; Mendoza-Santiesteban, Carlos
2015-01-01
Abstract Following the epidemic of optic and peripheral neuropathy, which occurred in Cuba between 1991 and 1993, a number of patients have been re-evaluated, including testing with optical coherence tomography (OCT) and electrophysiology. At the same time, a number of patients with Leber’s hereditary optic neuropathy have also been evaluated. The purpose of this study was to detect residual loss of retinal nerve fibre layer (RNFL) in patients who suffered Cuban epidemic optic neuropathy (CEON), and to compare these findings with those in patients with Leber’s hereditary optic neuropathy (LHON). Optical coherence tomography as well as clinical examinations were performed on 11 patients diagnosed with CEON 15 years following the epidemic and 14 patients with LHON. OCT in CEON patients showed thinning of the RNFL in the temporal sector and normal thickness in other quadrants. However, patients with chronic LHON had more diffuse RNFL loss throughout the retina. OCT findings corresponded with clinical findings in CEON and LHON. There was drop out of the papillomacular bundle in both diseases. Two patients in the acute stages of LHON and three LHON carriers showed thinning of the temporal RNFL only. This is the first report of OCT in CEON that shows residual damage in the papillomacular bundle compared with chronic LHON where there is more diffuse and progressive loss of the RNFL. The importance of OCT for the diagnosis and evaluation of similar optic neuropathies is emphasised. PMID:27928368
Enders, Philip; Adler, Werner; Schaub, Friederike; Hermann, Manuel M; Dietlein, Thomas; Cursiefen, Claus; Heindl, Ludwig M
2016-12-01
The purpose of this study was to assess the diagnostic power of the novel two-dimensional parameter Bruch's membrane opening minimal rim area (BMO-MRA) in spectral-domain optical coherence tomography (SD-OCT) for detection of glaucoma compared to minimal rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness in large and small optic discs. In this case-control, cross-sectional study, 207 eyes of 207 participants, including 89 controls and 97 patients with glaucoma and 21 with ocular hypertension (OHT), with a disc size <1.63 mm2 or >2.43 mm2 underwent SD-OCT, confocal laser scanning tomography (CSLT), visual field testing, and clinical examination. Bruch's membrane opening-MRA BMO-MRW, RNFL thickness of SD-OCT and disc margin rim area (DM-RA) of CSLT were evaluated and analyzed for diagnostic power to detect glaucoma. In healthy eyes with macrodiscs, mean BMO-MRW of 243.14 ± 43.12 μm was significantly smaller than BMO-MRW in microdiscs (338.97 ± 69.39; P < 0.001). Bruch's membrane opening-MRA was comparable between disc size groups with 1.22 ± 0.25 mm2 for macrodiscs and 1.26 ± 0.27 mm2 for microdiscs (P = 0.51), as was RNFL thickness (82.69 ± 15.76 μm versus 78.53 ± 11.01 μm, respectively; P = 0.28). Perimetric mean deviation was -8.7 ± 6.3 dB in glaucoma and -0.6 ± 1.60 dB in OHT patients. Correlation of BMO-MRA and visual field function was rho (ρ) = 0.70 (P < 0.001). Diagnostic power to differentiate glaucoma patients was highest for BMO-MRA. Partial area under the curve (pAUC) for BMO-MRA was 0.14 for specificity between 0.8 and 1.0, exceeding pAUCs of BMO-MRW (P < 0.001), RNFL thickness (P = 0.03), and DM-RA (P = 0.01). Bruch's membrane opening-based minimum rim area measurements offer advantages compared to one-dimensional parameters assessing neuroretinal rim by SD-OCT. In nonglaucomatous eyes, BMO-MRA values seem comparable for the full range of disc sizes. Bruch's membrane opening-MRA surpasses other parameters in diagnostic power for glaucoma.
Hood, Donald C
2007-05-01
Glaucoma causes damage to the retinal ganglion cells and their axons, and this damage can be detected with both structural and functional tests. The purpose of this study was to better understand the relationship between a structural measure of retinal nerve fiber layer (RNFL) and the most common functional test, behavioral sensitivity with static automated perimetry (SAP). First, a linear model, previously shown to describe the relationship between local visual evoked potentials and SAP sensitivity, was modified to predict the change in RNFL as measured by optical coherence tomography. Second, previous work by others was shown to be consistent with this model.
Abbott, Carla J; Choe, Tiffany E; Burgoyne, Claude F; Cull, Grant; Wang, Lin; Fortune, Brad
2014-01-01
To compare in young and old rats longitudinal measurements of retinal nerve fiber layer thickness (RNFLT) and axonal transport 3-weeks after chronic IOP elevation. IOP was elevated unilaterally in 2- and 9.5-month-old Brown-Norway rats by intracameral injections of magnetic microbeads. RNFLT was measured by spectral domain optical coherence tomography. Anterograde axonal transport was assessed from confocal scanning laser ophthalmolscopy of superior colliculi (SC) after bilateral intravitreal injections of cholera toxin-B-488. Optic nerve sections were graded for damage. Mean IOP was elevated in both groups (young 37, old 38 mmHg, p = 0.95). RNFL in young rats exhibited 10% thickening at 1-week (50.9±8.1 µm, p<0.05) vs. baseline (46.4±2.4 µm), then 7% thinning at 2-weeks (43.0±7.2 µm, p>0.05) and 3-weeks (43.5±4.4 µm, p>0.05), representing 20% loss of dynamic range. RNFLT in old rats showed no significant change at 1-week (44.9±4.1 µm) vs. baseline (49.2±5.3 µm), but progression to 22% thinning at 2-weeks (38.0±3.7 µm, p<0.01) and 3-weeks (40.0±6.6 µm, p<0.05), representing 59% loss of dynamic range. Relative SC fluorescence intensity was reduced in both groups (p<0.001), representing 77-80% loss of dynamic range and a severe transport deficit. Optic nerves showed 75-95% damage (p<0.001). There was greater RNFL thinning in old rats (p<0.05), despite equivalent IOP insult, transport deficit and nerve damage between age groups (all p>0.05). Chronic IOP elevation resulted in severely disrupted axonal transport and optic nerve axon damage in all rats, associated with mild RNFL loss in young rats but a moderate RNFL loss in old rats despite the similar IOP insult. Hence, the glaucomatous injury response within the RNFL depends on age.
Patel, Nimesh; Pass, Anastas; Mason, Sara; Gibson, Charles R; Otto, Christian
2018-02-01
After long-duration spaceflight, morphological changes in the optic nerve head (ONH) and surrounding tissues have been reported. To develop methods to quantify ONH and surrounding tissue changes using preflight and postflight optical coherence tomographic scans of the ONH region. Two separate analyses were done on retrospective data, with the first comparing a preflight group with a control group, followed by preflight to postflight analysis. All astronaut data were collected on the same instrument and maintained by the National Aeronautics and Space Administration (NASA) Lifetime Surveillance of Astronaut Health. Control data were all collected at the University of Houston. Participants were 15 astronauts who had previously been on an approximately 6-month long-duration mission and had associated preflight and postflight ONH scans. The control group consisted of 43 individuals with no history of ocular pathology or microgravity exposure. Development of algorithms and data analysis were performed between 2012 and 2015. The optical coherence tomography data were analyzed using custom MATLAB programs (MathWorks) in which the Bruch membrane opening (BMO) was manually delineated and used as a reference for all morphological measures. The retinal pigment epithelium (RPE) position 2 mm from the center of the BMO was used to calculate the BMO height. Global and quadrant total retinal thickness and retinal nerve fiber layer (RNFL) thickness were calculated for elliptical annular regions referenced to the BMO. The standard circumpapillary circular scan was used to quantify RNFL and choroidal thickness. Among 15 astronauts (mean [SD] age at preflight evaluation, 48.7 [4.0] years) in this retrospective study, the BMO was recessed in preflight astronauts compared with healthy controls and deepened after long-duration microgravity exposure (median change, -9.9 μm; 95% CI of difference, -16.3 to 3.7 μm; P = .03). After long-duration missions, there was an increase in total retinal thickness to 1000 μm and RNFL to 500 μm from the BMO. Circumpapillary RNFL thickness increased by a median of 2.9 μm (95% CI of difference, 1.1-4.4 μm; P < .01), and there was no change in choroidal thickness (median change, 9.3 μm; 95% CI of difference, -12.1 to 19.6 μm; P = .66). After long-duration microgravity exposure, there are disc edema-like changes in the morphology of the ONH and surrounding tissue. The methods developed to analyze the ONH and surrounding tissue can be useful for assessing longitudinal changes and countermeasures in astronauts, as well as potentially for terrestrial disc edema causes.
Mead, Ben; Hill, Lisa J; Blanch, Richard J; Ward, Kelly; Logan, Ann; Berry, Martin; Leadbeater, Wendy; Scheven, Ben A
2016-04-01
Glaucoma is a leading cause of irreversible blindness involving loss of retinal ganglion cells (RGC). Mesenchymal stromal cells (MSC) have shown promise as a paracrine-mediated therapy for compromised neurons. It is, however, unknown whether dental pulp stem cells (DPSC) are effective as a cellular therapy in glaucoma and how their hypothesized influence compares with other more widely researched MSC sources. The present study aimed to compare the efficacy of adipose-derived stem cells, bone marrow-derived MSC (BMSC) and DPSC in preventing the loss of RGC and visual function when transplanted into the vitreous of glaucomatous rodent eyes. Thirty-five days after raised intraocular pressure (IOP) and intravitreal stem cell transplantation, Brn3a(+) RGC numbers, retinal nerve fibre layer thickness (RNFL) and RGC function were evaluated by immunohistochemistry, optical coherence tomography and electroretinography, respectively. Control glaucomatous eyes that were sham-treated with heat-killed DPSC had a significant loss of RGC numbers, RNFL thickness and function compared with intact eyes. BMSC and, to a greater extent, DPSC provided significant protection from RGC loss and RNFL thinning and preserved RGC function. The study supports the use of DPSC as a neuroprotective cellular therapy in retinal degenerative disease such as glaucoma. Copyright © 2016 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Jeoung, Jin Wook; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung
2013-07-01
We evaluated the diagnostic accuracy of macular ganglion cell-inner plexiform layer (GCIPL) measurements using a high-definition optical coherence tomography (Cirrus HD-OCT) ganglion cell analysis algorithm for detecting early and moderate-to-severe glaucoma. Totals of 119 normal subjects and 306 glaucoma patients (164 patients with early glaucoma and 142 with moderate-to-severe glaucoma) were enrolled from the Macular Ganglion Cell Imaging Study. Macular GCIPL, peripapillary retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured in each subject. Areas under the receiver operating characteristic curves (AUROCs) were calculated and compared. Based on the internal normative database, the sensitivity and specificity for detecting early and moderate-to-severe glaucoma were calculated. There was no statistically significant difference between the AUROCs for the best OCT parameters. For detecting early glaucoma, the sensitivity of the Cirrus GCIPL parameters ranged from 26.8% to 73.2% and that of the Cirrus RNFL parameters ranged from 6.1% to 61.6%. For the early glaucoma group, the best parameter from the GCIPL generally had a higher sensitivity than those of the RNFL and ONH parameters with comparable specificity (P < 0.05, McNemar's test). There were no significant differences between the AUROCs for Cirrus GCIPL, RNFL, and ONH parameters, indicating that these maps have similar diagnostic potentials for glaucoma. The minimum GCIPL showed better glaucoma diagnostic performance than the other parameters at comparable specificities. However, other GCIPL parameters showed performances comparable to those of the RNFL parameters.
Initial Arcuate Defects within the Central 10 Degrees in Glaucoma
Raza, Ali S.; de Moraes, Carlos Gustavo V.; Odel, Jeffrey G.; Greenstein, Vivienne C.; Liebmann, Jeffrey M.; Ritch, Robert
2011-01-01
Purpose. To better understand the relationship between the spatial patterns of functional (visual field [VF] loss) and structural (axon loss) abnormalities in patients with glaucomatous arcuate defects largely confined to the central 10° on achromatic perimetry. Methods. Eleven eyes (9 patients) with arcuate glaucomatous VF defects largely confined to the macula were selected from a larger group of patients with both 10-2 and 24-2 VF tests. Eyes were included if their 10-2 VF had an arcuate defect and if the 24-2 test was normal outside the central 10° (i.e., did not have a cluster of three contiguous points within a hemifield). For the structural analysis, plots of retinal nerve fiber layer (RNFL) thickness of the macula were obtained with frequency-domain optical coherence tomography (fdOCT). The optic disc locations of the RNFL defects were identified on peripapillary fdOCT scans. Results. The VF arcuate defects extended to within 1° of fixation on the 10-2 test and were present in the superior hemifield in 10 of the 11 eyes. The arcuate RNFL damage, seen in the macular fdOCT scans of all 11 eyes, involved the temporal and inferior temporal portions of the disc on the peripapillary scans. Conclusions. Glaucomatous arcuate defects of the macula's RNFL meet the disc temporal to the peak of the main arcuate bundles and produce a range of macular VF defects from clear arcuate scotomas to a papillofoveal horizontal step (“pistol barrel scotoma”). If RGC displacement is taken into consideration, the RNFL and VF defects can be compared directly. PMID:20881293
Ozge, Gokhan; Koylu, Mehmet Talay; Mumcuoglu, Tarkan; Gundogan, Fatih Cakir; Ozgonul, Cem; Ayyildiz, Onder; Kucukevcilioglu, Murat
2016-05-01
To compare retinal nerve fiber layer thickness (RNFLT) and choroidal thickness (ChT) measurements in eyes with pseudoexfoliative (PEX) glaucoma, PEX syndrome and healthy control eyes. Eighteen patients with PEX glaucoma in one eye and PEX syndrome in the fellow eye were included. The right eyes of thirty-nine age- and sex-matched healthy subjects were included as control group. All participants underwent a detailed biomicroscopic and funduscopic examination. RNFLT and ChT measurements were performed with a commercially available spectral-domain optical coherence tomography (SD-OCT). ChT measurements were performed by using enhanced depth imaging (EDI) mode. Patients with PEX underwent diurnal IOP measurements with 4-hour intervals before inclusion in the study. RNFLT results included the average measurement and 6 quadrants (temporal, inferotemporal, inferonasal, nasal, superonasal and supero-temporal). ChT measurements were performed in the subfoveal region and around the fovea (500µm and 1500 µm nasal and temporal to the fovea), as well as around the optic disc (average peripapillary and eight quadrants in the peripapillary region (temporal, inferotemporal, inferior, inferonasal, nasal, superonasal, superior, supero-temporal)). RNFLT in all quadrants and average thickness were significantly lower in PEX glaucoma eyes compared to PEX syndrome eyes and healthy control eyes (p<0.001 for both). RNFLT comparisons between PEX syndrome and healthy control eyes did not show a significant difference (p>0.05) except the inferotemporal quadrant. ChT measurements were similar between groups (p>0.05). Thinning of the RNFL in association with unchanged ChT may mean that the presence of PEX material is a much more significant risk factor than choroidal changes in the progression of PEX syndrome to PEX glaucoma.
Yuvacı, İsa; Pangal, Emine; Bayram, Nurettin; Yüksel, Sevgi Arık; Alabay, Bedirhan; Ağadayı, Alperen; Sırakaya, Ender; Gülhan, Ahmet
2016-01-01
Evaluation of the nerve fiber thicknesses of the macula, choroid, and retina using the apnea-hypopnea index in individuals with obstructive sleep apnea syndrome (OSAS) without systemic components. Prospective, controlled study. The central macular, choroidal, and retinal nerve fiber layer (RNFL) thicknesses were evaluated using enhanced depth imaging-spectral domain optical coherence tomography in individuals with OSAS. In people with severe OSAS who had received treatment, posterior ocular structures were examined over 3 months (4th and 12th weeks), and changes were evaluated. Only the right eyes of the participants were evaluated in the study. A total of 72 people were involved in the study, with 18 in the control group and 19 with mild, 16 with moderate, and 19 with severe OSAS. No significant difference was found among the groups in terms of demographic measures. No significant differences were found among the groups in terms of the measures of central macular, central subfoveal choroidal (CSCT), temporal choroidal, nasal choroidal, and RNFL thicknesses. In severe OSAS cases in which treatment was administered, although subjective clinical recovery was observed, statistically significant thinning was detected during the 3-month follow-up period in the CSCT, general RNFL, as well as in the inferior and superior nasal quadrants, and temporal superior quadrant (p=0.005, p=0.009, p=0.039, p=0.003, and p=0.02, respectively). In the group with severe OSAS, thinning in some posterior ocular tissues was observed. Although patients with severe OSAS may experience clinical recovery, we recommend that they would be followed up in terms of ocular ischemic injury.
Lee, Seung Hyen; Lee, Eun Ji; Kim, Tae-Woo
2015-10-01
The optic disc pit (ODP) has been considered a region of localized susceptibility to the damage of glaucoma. To determine whether the rate of retinal nerve fiber layer (RNFL) thinning differs according to the presence and structural characteristics of an ODP in primary open-angle glaucoma. We performed a prospective case-control study that included 163 eyes with primary open-angle glaucoma (83 with an ODP and 80 without an ODP) from Glaucoma Clinic of Seoul National University Bundang Hospital. Participants were enrolled from the ongoing Investigating Glaucoma Progression Study from January 1, 2012, through May 31, 2014. Mean (SD) follow-up was 3.32 (0.49) years (through May 31, 2014). Optic nerve heads underwent swept-source optical coherence tomography (OCT) to determine the presence of focal lamina cribrosa alteration and its structural characteristics. Eyes with and without photographic ODPs and corresponding microscopic laminar alterations were assigned to the ODP and non-ODP groups, respectively. The rates of progressive thinning of global and 6 sectoral spectral-domain OCT RNFL thicknesses were determined by linear regression and compared between the 2 groups. We used a general linear model to determine the factors associated with the rate of RNFL thinning; data obtained from September 21, 2009, through May 31, 2014, were used to calculate the rate of RNFL thinning. The relationship between the presence and structural characteristics of ODPs and the rate of progressive OCT RNFL thinning. Thinning of the RNFL was faster in the ODP group than in the non-ODP group in the global (mean [SD], -1.44 [1.31] vs -0.93 [1.10] [95% CI, -0.97 to -0.19] μm/y; P = .008), temporoinferior (mean [SD], -4.17 [4.15] vs -1.97 [3.26] [95% CI, -3.36 to -1.04] μm/y; P < .001), and temporal (mean [SD], -1.92 [2.62] vs -0.89 [1.62] [95% CI, -1.70 to -0.35] μm/y; P = .003) sectors. The rate of RNFL thinning was maximum in the temporoinferior sector (mean [SD], -4.17 [4.15] μm/y) and corresponded to the frequency distribution of ODPs. Regression analysis revealed that faster global RNFL thinning was related to a higher untreated intraocular pressure (β = -0.07; 95% CI, -0.11 to -0.03; P = .001), episodes of disc hemorrhage (β = -0.74; 95% CI, -1.79 to 0.31; P = .003), the presence of β-zone parapapillary atrophy (β = -0.47; 95% CI, -1.13 to 0.20; P = .02), and the presence of ODPs (β = -0.41; 95% CI, -1.14 to 0.32; P = .02). The maximum rate of RNFL thinning was associated with higher untreated intraocular pressure (β = -0.24; 95% CI, -0.35 to -0.13; P < .001), disc hemorrhage (β = -1.54; 95% CI, -2.88 to -0.19; P < .001), and the presence (β = -1.04; 95% CI, -2.14 to 0.07; P = .004), far-peripheral location (β = -1.75; 95% CI, -3.05 to -0.46; P = .008), and partial-thickness depth (β = -1.45; 95% CI, -2.75 to -0.16; P = .03) of an ODP. The presence and structural characteristics of ODPs were associated with global and focal progression as assessed by the rate of OCT RNFL thinning. The assessment of ODP structure using swept-source OCT may help to predict the location of future progression.
Yadav, Ravi K; Begum, Viquar U; Addepalli, Uday K; Senthil, Sirisha; Garudadri, Chandra S; Rao, Harsha L
2016-02-01
To compare the abilities of retinal nerve fiber layer (RNFL) parameters of variable corneal compensation (VCC) and enhanced corneal compensation (ECC) algorithms of scanning laser polarimetry (GDx) in detecting various severities of glaucoma. Two hundred and eighty-five eyes of 194 subjects from the Longitudinal Glaucoma Evaluation Study who underwent GDx VCC and ECC imaging were evaluated. Abilities of RNFL parameters of GDx VCC and ECC to diagnose glaucoma were compared using area under receiver operating characteristic curves (AUC), sensitivities at fixed specificities, and likelihood ratios. After excluding 5 eyes that failed to satisfy manufacturer-recommended quality parameters with ECC and 68 with VCC, 56 eyes of 41 normal subjects and 161 eyes of 121 glaucoma patients [36 eyes with preperimetric glaucoma, 52 eyes with early (MD>-6 dB), 34 with moderate (MD between -6 and -12 dB), and 39 with severe glaucoma (MD<-12 dB)] were included for the analysis. Inferior RNFL, average RNFL, and nerve fiber indicator parameters showed the best AUCs and sensitivities both with GDx VCC and ECC in diagnosing all severities of glaucoma. AUCs and sensitivities of all RNFL parameters were comparable between the VCC and ECC algorithms (P>0.20 for all comparisons). Likelihood ratios associated with the diagnostic categorization of RNFL parameters were comparable between the VCC and ECC algorithms. In scans satisfying the manufacturer-recommended quality parameters, which were significantly greater with ECC than VCC algorithm, diagnostic abilities of GDx ECC and VCC in glaucoma were similar.
Peripapillary Retinoschisis in Glaucomatous Eyes
Lee, Eun Ji; Kim, Tae-Woo; Kim, Mijin; Choi, Yun Jeong
2014-01-01
Purpose To investigate the structural and clinical characteristics of peripapillary retinoschisis observed in glaucomatous eyes using spectral-domain optical coherence tomography (SD-OCT). Methods Circumpapillary retinal nerve fiber layer (cpRNFL) and macular cross-hair SD-OCT scans and infrared fundus images of the glaucoma patients from the Investigating Glaucoma Progression Study (IGPS) and healthy volunteers were reviewed. Optic disc images obtained using enhanced depth imaging (EDI) SD-OCT were also evaluated. The structural characteristics and clinical course of the retinoschisis associated with glaucoma were investigated. Results Twenty-five retinoschisis areas were found in 22 of the 372 patients (5.9%) included in the IGPS, and in 1 area in 1 of 187 healthy control subjects (0.5%). In the 22 glaucomatous eyes with retinoschisis, the schisis was attached to the optic disc and overlapped with the retinal nerve fiber layer (RNFL) defect. The RNFL was the layer most commonly affected by the retinoschisis, either alone or together with other deeper layers. Acquired optic disc pit was identified in 8 eyes on disc photography and/or B-scan images obtained by EDI SD-OCT. Spontaneous resolution of this condition was observed in nine eyes. No retinal detachment or macular involvement of the retinoschisis was observed in any of the eyes. Multivariate analysis showed a significant influence of a higher intraocular pressure at SD-OCT scanning on the presence of retinoschisis (Odds ratio = 1.418, P = 0.001). Conclusions The present study investigated 22 cases of peripapillary retinoschisis in glaucomatous eyes. The retinoschisis was attached to the optic nerve and topographically correlated with RNFL defect. It often resolved spontaneously without causing severe visual disturbance. Care should be taken not to overestimate the RNFL thickness in eyes with retinoschisis, and also not to misinterpret the resolution of retinoschisis as a rapid glaucomatous RNFL deterioration. PMID:24587238
Faria, Mun Yueh; Ferreira, Nuno P; Cristóvao, Diana M; Mano, Sofia; Sousa, David Cordeiro; Monteiro-Grillo, Manuel
2018-01-01
To highlight tomographic structural changes of retinal layers after internal limiting membrane (ILM) peeling in macular hole surgery. Nonrandomized prospective, interventional study in 38 eyes (34 patients) subjected to pars plana vitrectomy and ILM peeling for idiopathic macular hole. Retinal layers were assessed in nasal and temporal regions before and 6 months after surgery using spectral domain optical coherence tomography. Total retinal thickness increased in the nasal region and decreased in the temporal region. The retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) showed thinning on both nasal and temporal sides of the fovea. The thickness of the outer plexiform layer (OPL) increased. The outer nuclear layer (ONL) and outer retinal layers (ORL) increased in thickness after surgery in both nasal and temporal regions. ILM peeling is associated with important alterations in the inner retinal layer architecture, with thinning of the RNFL-GCL-IPL complex and thickening of OPL, ONL, and ORL. These structural alterations can help explain functional outcome and could give indications regarding the extent of ILM peeling, even though peeling seems important for higher rate of hole closure. © 2017 S. Karger AG, Basel.
Distinguishing ischaemic optic neuropathy from optic neuritis by ganglion cell analysis.
Erlich-Malona, Natalie; Mendoza-Santiesteban, Carlos E; Hedges, Thomas R; Patel, Nimesh; Monaco, Caitlin; Cole, Emily
2016-12-01
To determine whether a pattern of altitudinal ganglion cell loss, as detected and measured by optical coherence tomography (OCT), can be used to distinguish non-arteritic ischaemic optic neuropathy (NAION) from optic neuritis (ON) during the acute phase, and whether the rate or severity of ganglion cell loss differs between the two diseases. We performed a retrospective, case-control study of 44 patients (50 eyes) with ON or NAION and 44 age-matched controls. Non-arteritic ischaemic optic neuropathy and ON patients had OCT at presentation and four consecutive follow-up visits. Controls had OCT at one point in time. The ganglion cell complex (GCC) was evaluated in the macula, and the retinal nerve fibre layer (RNFL) was evaluated in the peripapillary region. Ganglion cell complex thickness, RNFL thickness and GCC mean superior and inferior hemispheric difference were compared between NAION and ON patients at each time-point using unpaired t-tests and between disease and control subjects at first measurement using paired t-tests. Mean time from onset of symptoms to initial presentation was 10.7 ± 6.6 days in NAION and 11.7 ± 8.6 days in ON (p = 0.67). There was a significantly greater vertical hemispheric difference in GCC thickness in NAION patients than ON patients at all time-points (5.5-10.7 μm versus 3.1-3.6 μm, p = 0.01-0.049). Mean GCC thickness was significantly decreased at less than 2 weeks after onset in NAION compared to age-matched controls (72.1 μm versus 82.1 μm, p < 0.001), as well as in ON compared to age-matched controls (74.3 μm versus 84.5 μm, p < 0.001). Progression and severity of GCC and RNFL loss did not differ significantly between NAION and ON. A quantitative comparison of mean superior and inferior hemispheric GCC thickness with OCT may be used to distinguish NAION from ON. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Lleó-Pérez, A; Ortuño-Soto, A; Rahhal, M S; Martínez-Soriano, F; Sanchis-Gimeno, J A
2004-01-01
To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and achromatic automated perimetry. RNFL were measured using scanning laser polarimeter (GDx-VCC) and optical coherence tomography (OCT Model 3000). Reproducibility of the RNFL measurements obtained with both nerve fiber analyzers were compared using the coefficient of variation. In both groups the authors found fair correlations between the two methods in all ratio and thickness parameters. The mean coefficient of variation for measurement of the variables ranged from 2.24% to 13.12% for GDx-VCC, and from 5.01% to 9.24% for OCT Model 3000. The authors could not detect any significant differences between healthy and ocular hypertensive eyes, although in normal eyes the correlations improved slightly. Nevertheless, the test-retest correlation was slightly better for GDx-VCC than for OCT Model 3000 (5.55% and 7.11%, respectively). Retinal mapping software of both nerve fiber analyzers allows reproducible measurement of RNFL in both healthy subjects and ocular hypertensive eyes, and shows fair correlations and good intraobserver reproducibility. However, in our study, GDx showed a better test-retest correlation.
Civelekler, Mustafa; Halili, Ismail; Gundogan, Faith C; Sobaci, Gungor
2009-01-01
Purpose: To investigate the value of temporal retinal nerve fiber layer (RNFLtemporal) thickness in the prediction of malingering. Materials and Methods: This prospective, cross-sectional study was conducted on 33 military conscripts with optic disc temporal pallor (ODTP) and 33 age-and sex-matched healthy controls. Initial visual acuity (VAi) and visual acuity after simulation examination techniques (VAaset) were assessed. The subjects whose VAaset were two or more lines higher than VAi were determined as malingerers. Thickness of the peripapillary RNFL was determined with OCT (Stratus OCT™, Carl Zeiss Meditec, Inc.). RNFLtemporal thickness of the subjects were categorized into one of the 1+ to 4+ groups according to 50% confidence interval (CI), 25% CI and 5% CI values which were assessed in the control group. The VAs were converted to LogMAR-VAs for statistical comparisons. Results: A significant difference was found only in the temporal quadrant of RNFL thickness in subjects with ODTP (P=0.002). Mean LogMAR-VA increased significantly after SETs (P<0.001). Sensitivity, specificity, positive and negative predictive values of categorized RNFLtemporal thickness in diagnosing malingering were 84.6%, 75.0%, 68.8%, 88.2%, respectively. ROC curve showed that RNFLtemporal thickness of 67.5 μm is a significant cut-off point in determining malingering (P=0.001, area under the curve:0.862). The correlations between LogMAR-VAs and RNFLtemporal thicknesses were significant; the correlation coefficient for LogMAR-VAi was lower than the correlation for LogMAR-VAaset (r=−0.447, P=0.009 for LogMAR-VAi; r=−0.676, P<0.001 for LogMAR-VAaset). Conclusions: RNFLtemporal thickness assessment may be a valuable tool in determining malingering in subjects with ODTP objectively. PMID:19700875
Fallon, M; Pazos, M; Morilla, A; Sebastián, M A; Xancó, R; Mora, C; Calderón, B; Vega, Z; Antón, A
2015-11-01
To evaluate morphological parameters of optic disc and retinal nerve fiber layer (RNFL) examined with confocal laser tomography (HRT3) and laser polarimetry (GDx-VCC) in a normal population, and analyze correlations of these parameters with demographic variables. Cross-sectional study in the context of a glaucoma screening campaign in the primary care center of Barcelona. The individuals selected were non-hypertensive Mediterranean Caucasians with risk for glaucoma development (individuals≥60 years old or≥40 years old with family history of glaucoma or intraocular pressure or myopia>3diopter). All subjects underwent a complete ophthalmic examination, confocal laser tomography (HRT3) and scanning laser polarimetry (GDX-VCC), subjects with results within normal limits only being included. Structural parameters were analyzed along with age, refraction, and pachymetry based on the Spearman rank correlation test. A total of 224 subjects included, with a mean age of 63.4±11.1 years. Disc areas, excavation and ring area were 2.14±0.52mm(2), 0.44±0.34mm (2) and 1.69±0.38mm(2), respectively. The mean RNFL (GDX) was 55.9±6.9μm. Age was correlated with lower ring volume, highest rate of cup shape measure, largest mean and maximum cup depth, lower nerve fiber index (NFI) and RNFL (all p-values below .05). The mean values and distribution of several parameters of the papilla and the RNFL in normal Mediterranean Caucasians population are presented. A loss of thickness of the RNFL, ring thinning, and enlarged cup was observed with increased age. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Tiryaki Demir, Semra; Oba, Mehmet Ersin; Erdoğan, Ezgi Tuna; Odabaşı, Mahmut; Dirim, Ayşe Burcu; Demir, Mehmet; Can, Efe; Kara, Orhan; Yekta Şendül, Selam
2015-01-01
Objectives: To investigate the correlation of visual field (VF), pattern electroretinography (PERG) and Fourier domain optical coherence tomography (FD-OCT) results in patients with ocular hypertension (OHT) and early primary open-angle glaucoma (POAG). Materials and Methods: The study included 72 eyes of 37 patients with early POAG, 76 eyes of 38 patients with OHT, and 60 eyes of 30 controls. All subjects underwent full ophthalmologic examination, VF assessment with 24-2 Humphrey standard automated perimetry (Swedish Interactive Thresholding Algorithm (SITA)-Standard), retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness measurement with FD-OCT, and PERG P50 and N95 wave latency and amplitude measurements with electroretinography (Nihon Kohden). Results: With the exception of the nasal quadrant, all GCC parameters and RNFL results were significantly lower in the POAG group compared to the OHT and control groups. There was no statistically significant difference between the OHT and control group. PERG amplitudes were lower in the POAG and OHT groups than in the control group. Reduction in N95 amplitude was greater than that of P50 amplitude. No difference was detected in PERG latencies among groups. GCC was significantly correlated with VF and RNFL in the POAG group. Conclusion: Significant thinning of the GCC and RNFL occurs in addition to VF pathologies in patients with early POAG, and these examinations should be concomitantly evaluated. During diagnostic assessment of patients with early POAG, GCC and RNFL analysis by FD-OCT are highly effective. GCC is as reliable as RNLF in the early diagnosis of glaucoma and there is a highly significant correlation between them. Dysfunction of ganglion cells in patients with OHT may be detected earlier using PERG amplitude analysis. PMID:27800239
Are All Retinal Nerve Fiber Layer Defects on Optic Coherence Tomography Glaucomatous?
Gür Güngör, Sirel; Ahmet, Akman
2017-01-01
Objectives: In this study, we investigated the patients who were referred to our clinic with a prediagnosis of glaucoma based on retinal nerve fiber layer (RNFL) defects on optic coherence tomography (OCT) but were determined to have nonglaucomatous RNLF defects upon detailed examination. Materials and Methods: The ophthalmic examination notes, OCT images, Heidelberg retinal tomography (HRT) II and fundus photographs of 357 patients were retrospectively evaluated. Final diagnoses of these patients were investigated. Results: Of the 357 patients, 216 (60.5%) were diagnosed as open angle glaucoma, 33 (9.2%) as low-tension glaucoma, 39 (10.9%) as pre-perimetric glaucoma. The ophthalmic examinations of 14 patients (3.9%) were normal and there were no RNFL defects in OCT examinations after dilatation. In 39 patients (10.9%), the ophthalmic and optic disc examinations were completely normal and no etiologic factor explaining RNFL defects was found. Twenty-two eyes of 16 patients (4.5%) were included in this study (the mean age was 53.8±11.5 years; 9 men and 7 women). After detailed questioning of the medical history and systemic and neurologic examinations, a diagnosis of ischemic optic neuropathy was made in 11 eyes (10 patients) (2.8%), optic neuritis in 3 eyes (2 patients) (0.6%), optic disc drusen in 4 eyes (2 patients) (0.6%), pseudotumor cerebri in 2 eyes (1 patient) (0.3%), and cerebral palsy in 2 eyes (1 patient) (0.3%). Conclusion: Decrease in RNFL thickness on OCT images alone may be misleading in glaucoma examination. In cases where optic disc cupping is not evident, diagnosis should not be based on OCT RNFL examinations alone, and the patient’s medical history, detailed ophthalmic examination, OCT optic disc parameters, HRT, and visual field tests should all be carefully evaluated together. PMID:29109895
Choroidal thickness in Chinese patients with non-arteritic anterior ischemic optic neuropathy.
Jiang, Libin; Chen, Lanlan; Qiu, Xiujuan; Jiang, Ran; Wang, Yaxing; Xu, Liang; Lai, Timothy Y Y
2016-08-31
Non-arteritic anterior ischemic optic neuropathy (NA-AION) is one of the most common types of ischemic optic neuropathy. Several recent studies suggested that abnormalities of choroidal thickness might be associated with NA-AION. The main objective of this case-control study was to evaluate whether choroidal thickness is an ocular risk factor for the development of NA-AION by evaluating the peripapillary and subfoveal choroidal thicknesses in affected Chinese patients. Forty-four Chinese patients with unilateral NA-AION were recruited and compared with 60 eyes of 60 normal age and refractive-error matched control subjects. Peripapillary and subfoveal choroidal thicknesses were measured by enhanced depth imaging optical coherence tomography. Choroidal thicknesses of eyes with NA-AION and unaffected fellow eyes were compared with normal controls. Choroidal thicknesses of NA-AION eyes with or without optic disc edema were also compared. The correlation between choroidal thickness and retinal nerve fiber layer (RNFL) thickness, logMAR best-corrected visual acuity (BCVA), and the mean deviation (MD) of Humphrey static perimetry in NA-AION eyes were analyzed. The peripapillary choroidal thicknesses at the nasal, nasal inferior and temporal inferior segments in NA-AION eyes with optic disc edema were significantly thicker compared with that of normal subjects (P < 0.05). There was no significant difference in the choroidal thicknesses between the unaffected fellow eyes of NA-AION patients and normal eyes of healthy controls; or between the NA-AION eyes with resolved optic disc edema and normal eyes (all P > 0.05). No significant correlation between choroidal thickness and RNFL thickness, logMAR BCVA and perimetry MD was found in eyes affected by NA-AION (all P > 0.05). Increase in peripapillary choroid thickness in some segments was found in NA-ION eyes with optic disc edema. However, our findings do not support the hypothesis that choroidal thickness is abnormal in Chinese patients with NA-AION compared with normal subjects with similar age and refractive error status.
Kim, Dong Myung; Seo, Je Hyun; Kim, Seok Hwan; Hwang, Seung-Sik
2007-05-01
To compare the features of localized retinal nerve fiber layer (RNFL) defects between a low-teen intraocular pressure (IOP) group and a high-teen IOP group in normal-tension glaucoma (NTG) patients. Seventy-seven eyes of 77 NTG patients showing localized RNFL defects on RNFL photographs and corresponding visual filed defects at the initial visit to a glaucoma specialist were selected for this study. Patients with range of diurnal IOP within low-teen or high-teen in both eyes were included. All participants completed refraction, diurnal IOP measurement, central corneal thickness (CCT) measurement, stereoscopic disc photography, RNFL photography, and automated perimetry. On RNFL photograph, approximation of the defect to the macula (angle alpha) and width of the defects (angle beta) were measured to represent RNFL defects. The patients were divided into 2 groups according to the level of IOP. A low-teen group had highest IOP of
Gracitelli, Carolina P. B.; Tatham, Andrew J.; Zangwill, Linda M.; Weinreb, Robert N.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Paranhos, Augusto; Baig, Saif; Medeiros, Felipe A.
2016-01-01
Purpose We examined the relationship between relative afferent pupillary defects (RAPDs) and macular structural damage measured by macular thickness and macular ganglion cell-inner plexiform layer (mGCIPL) thickness in patients with glaucoma. Methods A cross-sectional study was done of 106 glaucoma patients and 85 healthy individuals from the Diagnostic Innovations in Glaucoma Study. All subjects underwent standard automated perimetry (SAP) and optic nerve and macular imaging using Cirrus Spectral Domain Optical Coherence Tomography (SDOCT). Glaucoma was defined as repeatable abnormal SAP or progressive glaucomatous changes on stereo photographs. Pupil responses were assessed using an automated pupillometer, which records the magnitude of RAPD (RAPD score), with additional RAPD scores recorded for each of a series of colored stimuli (blue, red, green, and yellow). The relationship between RAPD score and intereye differences (right minus left eye) in circumpapillary retinal nerve fiber layer (cpRNFL) thickness, mGCIPL, macular thickness, and SAP mean deviation (MD), was examined using linear regression. Results There was fair correlation between RAPD score and asymmetric macular structural damage measured by intereye difference in mGCIPL thickness (R2 = 0.285, P < 0.001). The relationship between RAPD score and intereye difference in macular thickness was weaker (R2 = 0.167, P < 0.001). Intereye difference in cpRNFL thickness (R2 = 0.350, P < 0.001) and SAP MD (R2 = 0.594, P < 0.001) had stronger association with RAPD scores compared to intereye difference in mGCIPL and macular thickness. Conclusions Objective assessment of pupillary responses using a pupillometer was associated with asymmetric macular structural damage in patients with glaucoma. PMID:27064394
Araki, Syunsuke; Miki, Atsushi; Goto, Katsutoshi; Yamashita, Tsutomu; Takizawa, Go; Haruishi, Kazuko; Ieki, Yoshiaki; Kiryu, Junichi; Yaoeda, Kiyoshi
2017-09-15
To investigate macular retinal and choroidal thickness in amblyopic eyes compared to that in fellow and normal eyes using swept-source optical coherence tomography (SS-OCT). This study examined 31 patients with hyperopic anisometropic amblyopia (6.9 ± 3.8 years, mean ± standard deviation), 15 patients with strabismic amblyopia without anisometropia (7.9 ± 4.2 years), and 24 age-matched controls (7.8 ± 3.3 years). Retinal and choroidal thickness was measured by 3D scans using SS-OCT. A 6-mm area around the fovea was automatically analyzed using the Early Treatment Diabetic Retinopathy Study map. The thickness from SS-OCT was corrected for magnification error using individual axial length, spherical refraction, cylinder refraction, and corneal radius. Retinal thickness was divided into the macular retinal nerve fiber layer (mRNFL), ganglion cell layer + inner plexiform layer (GCL+IPL), ganglion cell complex (GCC), and the inner limiting membrane to the retinal pigment epithelium (ILM-RPE) thickness. Retinal and choroidal thickness was compared among amblyopic, fellow, and normal eyes. In both amblyopia groups, there was no significant difference in the mRNFL, GCL+IPL, and GCC thicknesses among the amblyopic, fellow, and control eyes. In the anisometropic amblyopia group, choroidal thickness (subfovea, center 1 mm, nasal and inferior of the inner ring, nasal of the outer ring, and center 6 mm) of amblyopic eyes were significantly greater than that of fellow and normal eyes. In contrast, none of the choroidal thicknesses were significantly different among the investigated eyes in the strabismic amblyopia group. We found no significant difference in inner retinal thickness in patients with unilateral amblyopia. Although there were significant differences in choroidal thickness with hyperopic anisometropic amblyopia, there was no significant difference for the strabismic amblyopia. The discrepancy in choroidal thickness between the two types of amblyopia may be due to both differences in ocular size and underlying mechanism.
Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan
2015-03-01
To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Contrast Sensitivity Perimetry and Clinical Measures of Glaucomatous Damage
Swanson, William H.; Malinovsky, Victor E.; Dul, Mitchell W.; Malik, Rizwan; Torbit, Julie K.; Sutton, Bradley M.; Horner, Douglas G.
2014-01-01
ABSTRACT Purpose To compare conventional structural and functional measures of glaucomatous damage with a new functional measure—contrast sensitivity perimetry (CSP-2). Methods One eye each was tested for 51 patients with glaucoma and 62 age-similar control subjects using CSP-2, size III 24-2 conventional automated perimetry (CAP), 24-2 frequency-doubling perimetry (FDP), and retinal nerve fiber layer (RNFL) thickness. For superior temporal (ST) and inferior temporal (IT) optic disc sectors, defect depth was computed as amount below mean normal, in log units. Bland-Altman analysis was used to assess agreement on defect depth, using limits of agreement and three indices: intercept, slope, and mean difference. A criterion of p < 0.0014 for significance used Bonferroni correction. Results Contrast sensitivity perimetry-2 and FDP were in agreement for both sectors. Normal variability was lower for CSP-2 than for CAP and FDP (F > 1.69, p < 0.02), and Bland-Altman limits of agreement for patient data were consistent with variability of control subjects (mean difference, −0.01 log units; SD, 0.11 log units). Intercepts for IT indicated that CSP-2 and FDP were below mean normal when CAP was at mean normal (t > 4, p < 0.0005). Slopes indicated that, as sector damage became more severe, CAP defects for IT and ST deepened more rapidly than CSP-2 defects (t > 4.3, p < 0.0005) and RNFL defects for ST deepened more slowly than for CSP, FDP, and CAP. Mean differences indicated that FDP defects for ST and IT were on average deeper than RNFL defects, as were CSP-2 defects for ST (t > 4.9, p < 0.0001). Conclusions Contrast sensitivity perimetry-2 and FDP defects were deeper than CAP defects in optic disc sectors with mild damage and revealed greater residual function in sectors with severe damage. The discordance between different measures of glaucomatous damage can be accounted for by variability in people free of disease. PMID:25259758
Contrast sensitivity perimetry and clinical measures of glaucomatous damage.
Swanson, William H; Malinovsky, Victor E; Dul, Mitchell W; Malik, Rizwan; Torbit, Julie K; Sutton, Bradley M; Horner, Douglas G
2014-11-01
To compare conventional structural and functional measures of glaucomatous damage with a new functional measure-contrast sensitivity perimetry (CSP-2). One eye each was tested for 51 patients with glaucoma and 62 age-similar control subjects using CSP-2, size III 24-2 conventional automated perimetry (CAP), 24-2 frequency-doubling perimetry (FDP), and retinal nerve fiber layer (RNFL) thickness. For superior temporal (ST) and inferior temporal (IT) optic disc sectors, defect depth was computed as amount below mean normal, in log units. Bland-Altman analysis was used to assess agreement on defect depth, using limits of agreement and three indices: intercept, slope, and mean difference. A criterion of p < 0.0014 for significance used Bonferroni correction. Contrast sensitivity perimetry-2 and FDP were in agreement for both sectors. Normal variability was lower for CSP-2 than for CAP and FDP (F > 1.69, p < 0.02), and Bland-Altman limits of agreement for patient data were consistent with variability of control subjects (mean difference, -0.01 log units; SD, 0.11 log units). Intercepts for IT indicated that CSP-2 and FDP were below mean normal when CAP was at mean normal (t > 4, p < 0.0005). Slopes indicated that, as sector damage became more severe, CAP defects for IT and ST deepened more rapidly than CSP-2 defects (t > 4.3, p < 0.0005) and RNFL defects for ST deepened more slowly than for CSP, FDP, and CAP. Mean differences indicated that FDP defects for ST and IT were on average deeper than RNFL defects, as were CSP-2 defects for ST (t > 4.9, p < 0.0001). Contrast sensitivity perimetry-2 and FDP defects were deeper than CAP defects in optic disc sectors with mild damage and revealed greater residual function in sectors with severe damage. The discordance between different measures of glaucomatous damage can be accounted for by variability in people free of disease.
Automated diagnosis of diabetic retinopathy and glaucoma using fundus and OCT images.
Pachiyappan, Arulmozhivarman; Das, Undurti N; Murthy, Tatavarti Vsp; Tatavarti, Rao
2012-06-13
We describe a system for the automated diagnosis of diabetic retinopathy and glaucoma using fundus and optical coherence tomography (OCT) images. Automatic screening will help the doctors to quickly identify the condition of the patient in a more accurate way. The macular abnormalities caused due to diabetic retinopathy can be detected by applying morphological operations, filters and thresholds on the fundus images of the patient. Early detection of glaucoma is done by estimating the Retinal Nerve Fiber Layer (RNFL) thickness from the OCT images of the patient. The RNFL thickness estimation involves the use of active contours based deformable snake algorithm for segmentation of the anterior and posterior boundaries of the retinal nerve fiber layer. The algorithm was tested on a set of 89 fundus images of which 85 were found to have at least mild retinopathy and OCT images of 31 patients out of which 13 were found to be glaucomatous. The accuracy for optical disk detection is found to be 97.75%. The proposed system therefore is accurate, reliable and robust and can be realized.
Automated diagnosis of diabetic retinopathy and glaucoma using fundus and OCT images
2012-01-01
We describe a system for the automated diagnosis of diabetic retinopathy and glaucoma using fundus and optical coherence tomography (OCT) images. Automatic screening will help the doctors to quickly identify the condition of the patient in a more accurate way. The macular abnormalities caused due to diabetic retinopathy can be detected by applying morphological operations, filters and thresholds on the fundus images of the patient. Early detection of glaucoma is done by estimating the Retinal Nerve Fiber Layer (RNFL) thickness from the OCT images of the patient. The RNFL thickness estimation involves the use of active contours based deformable snake algorithm for segmentation of the anterior and posterior boundaries of the retinal nerve fiber layer. The algorithm was tested on a set of 89 fundus images of which 85 were found to have at least mild retinopathy and OCT images of 31 patients out of which 13 were found to be glaucomatous. The accuracy for optical disk detection is found to be 97.75%. The proposed system therefore is accurate, reliable and robust and can be realized. PMID:22695250
Hood, Donald C; Anderson, Susan C; Wall, Michael; Raza, Ali S; Kardon, Randy H
2009-09-01
Retinal nerve fiber (RNFL) thickness and visual field loss data from patients with glaucoma were analyzed in the context of a model, to better understand individual variation in structure versus function. Optical coherence tomography (OCT) RNFL thickness and standard automated perimetry (SAP) visual field loss were measured in the arcuate regions of one eye of 140 patients with glaucoma and 82 normal control subjects. An estimate of within-individual (measurement) error was obtained by repeat measures made on different days within a short period in 34 patients and 22 control subjects. A linear model, previously shown to describe the general characteristics of the structure-function data, was extended to predict the variability in the data. For normal control subjects, between-individual error (individual differences) accounted for 87% and 71% of the total variance in OCT and SAP measures, respectively. SAP within-individual error increased and then decreased with increased SAP loss, whereas OCT error remained constant. The linear model with variability (LMV) described much of the variability in the data. However, 12.5% of the patients' points fell outside the 95% boundary. An examination of these points revealed factors that can contribute to the overall variability in the data. These factors include epiretinal membranes, edema, individual variation in field-to-disc mapping, and the location of blood vessels and degree to which they are included by the RNFL algorithm. The model and the partitioning of within- versus between-individual variability helped elucidate the factors contributing to the considerable variability in the structure-versus-function data.
Protective effect of high concentration of BN52021 on retinal contusion in cat eyes.
Huang, Jin-Feng; Zhao, Hai-Peng; Yang, Yan-Feng; Huang, Hui-Min; Yao, Yi; Wang, Zhi-Jun
2015-05-09
Blunt injuries/contusion on eyes might cause retina blunt trauma. This study is to evaluate the protective function of BN52021 against retinal trauma. A total of 70 cats, 6 months old, were divided into six groups: Group A to E (n = 12) and normal control (N) group (n = 10). The right eyes in Group A to E were contused. All experiments were performed under general anesthetization. Retrobulbar injections of medication in right eyes were performed. Cats were administrated with 0.5 mL of normal saline (NS), dimethyl sulphoxide, 0.2 g/L BN52021, 1 g/L BN52021 and 5 g/L BN52021, respectively. Cats in Group N were administrated with 0.5 mL of NS. Intraocular pressure (IOP), flash electroretinogram (ERG), and retinal nerve fiber layer (RNFL) thickness were measured. Hematoxylin and eosin (HE) staining and transmission electron microscope (TEM) were detected. No significant difference was observed in IOP levels among groups. Comparing with cats in Group N, those in Group A to E showed significant lower amplitudes of rod a- and b-waves (P < 0.05). Amplitudes of rod a- and b-waves were increased by administration of high concentration of BN52021 (≥ 1 g/L). Moreover, high concentration of BN52021 decreased the RNFL thickness increased by contusion. Axons in RNFL in Group E arranged neatly at 7 days after modeling. The degenerated axons caused by contusion were repaired by BN52021. The administration of high concentration of (≥ 1 g/L) BN52021 could partially repair retinal function in contused cat eyes.
Kremmer, Stephan; Keienburg, Marcus; Anastassiou, Gerasimos; Schallenberg, Maurice; Steuhl, Klaus-Peter; Selbach, J Michael
2012-01-01
To compare the performance of scanning laser topography (SLT) and scanning laser polarimetry (SLP) on the rim of the optic nerve head and its surrounding area and thereby to evaluate whether these imaging technologies are influenced by other factors beyond the thickness of the retinal nerve fiber layer (RNFL). A total of 154 eyes from 5 different groups were examined: young healthy subjects (YNorm), old healthy subjects (ONorm), patients with normal tension glaucoma (NTG), patients with open-angle glaucoma and early glaucomatous damage (OAGE) and patients with open-angle glaucoma and advanced glaucomatous damage (OAGA). SLT and SLP measurements were taken. Four concentric circles were superimposed on each of the images: the first one measuring at the rim of the optic nerve head (1.0 ONHD), the next measuring at 1.25 optic nerve head diameters (ONHD), at 1.5 ONHD and at 1.75 ONHD. The aligned images were analyzed using GDx/NFA software. Both methods showed peaks of RNFL thickness in the superior and inferior segments of the ONH. The maximum thickness, registered by the SLT device was at the ONH rim where the SLP device tended to measure the lowest values. SLT measurements at the ONH were influenced by other tissues besides the RNFL like blood vessels and glial tissues. SLT and SLP were most strongly correlated at distances of 1.25 and 1.5 ONHD. While both imaging technologies are valuable tools in detecting glaucoma, measurements at the ONH rim should be interpreted critically since both methods might provide misleading results. For the assessment of the retinal nerve fiber layer we would like to recommend for both imaging technologies, SLT and SLP, measurements in 1.25 and 1.5 ONHD distance of the rim of the optic nerve head.
Effect of optic neuritis on progressive axonal damage in multiple sclerosis patients.
Garcia-Martin, E; Pueyo, V; Ara, J R; Almarcegui, C; Martin, J; Pablo, L; Dolz, I; Sancho, E; Fernandez, F J
2011-07-01
The objective of this research was to study the effect of optic neuritis (ON) on axonal damage in multiple sclerosis (MS) patients. Specifically, we compared changes over 2 years in the retinal nerve fibre layer (RNFL) between affected and contralateral eyes in MS patients with a prior history of ON. Thirty-four patients with one unilateral definitive episode of ON were included and underwent a complete ophthalmic examination, optical coherence tomography (OCT), scanning laser polarimetry, visual evoked potentials (VEP) and pattern electroretinogram (pERG). All patients were re-evaluated at 12 and 24 months. Parameters were compared between ON-affected and contralateral eyes in an initial exploration and over the course of the follow-up. Correlations between parameter changes were analysed. RNFL thickness and functional parameters showed more affection in ON eyes (p ≤ 0.05), but changes in measurements during the study were similar between both groups of eyes. Progressive axonal loss can be detected in the optic nerve, but ON is not a risk factor for increased chronic damage in MS patients without ophthalmic relapses. Loss of the RNFL is caused by progressive degeneration associated with the disease.
Analysis of various factors affecting pupil size in patients with glaucoma.
Park, Ji Woong; Kang, Bong Hui; Kwon, Ji Won; Cho, Kyong Jin
2017-09-16
Pupil size is an important factor in predicting post-operative satisfaction. We assessed the correlation between pupil size, measured by Humphrey static perimetry, and various affecting factors in patients with glaucoma. In total, 825 eyes of 415 patients were evaluated retrospectively. Pupil size was measured with Humphrey static perimetry. Comparisons of pupil size according to the presence of glaucoma were evaluated, as were correlations between pupil size and various factors, including age, logMAR best corrected visual acuity (BCVA), retinal nerve fiber layer (RNFL) thickness, spherical equivalent, intraocular pressure, axial length, central corneal thickness, white-to-white, and the kappa angle. Pupil size was significantly smaller in glaucoma patients than in glaucoma suspects (p < 0.001) or the normal group (p < 0.001). Pupil size decreased significantly as age (p < 0.001) and central cornea thickness (p = 0.007) increased, and increased significantly as logMAR BCVA (p = 0.02) became worse and spherical equivalent (p = 0.007) and RNFL thickness (p = 0.042) increased. In patients older than 50 years, pupil size was significantly larger in eyes with a history of cataract surgery. Humphrey static perimetry can be useful in measuring pupil size. Pupil size was significantly smaller in eyes with glaucoma. Other factors affecting pupil size can be used in a preoperative evaluation when considering cataract surgery or laser refractive surgery.
Ely, Amanda L; El-Dairi, Mays A; Freedman, Sharon F
2014-11-01
To identify optic nerve head (ONH) cupping reversal and associated optical coherence tomography (OCT) and Humphrey visual field changes in pediatric glaucoma. Retrospective observational case series. Sequential surgical cases of juvenile open-angle glaucoma (OAG) or primary congenital glaucoma (PCG) with sustained postoperative intraocular pressure (IOP) reduction. Group 1 had preoperative and postoperative ONH photographs and OCT; Group 2 had preoperative clinical ONH assessment and postoperative imaging. Cupping evaluation was confirmed by masked glaucoma and neuro-ophthalmology specialists. Of 80 cases, 9 eyes (9 children) met criteria for Group 1; 24 eyes (19 children) met criteria for Group 2. Group 1: Five of 9 eyes (56%) demonstrated cupping reversal, with preoperative vs postoperative mean IOP 34.2 ± 6.6 mm Hg vs 10.6 ± 4.1 mm Hg (P < .00001) and mean average retinal nerve fiber layer (RNFL) 71.0 ± 30 μm vs 62.8 ± 24 μm (P = .4), respectively. RNFL was stable in 4 of 5 eyes (all juvenile OAG), but thinned (Δ = -41 μm) in 1 eye with PCG. Humphrey visual fields (reliable in 2 of 3 eyes) showed no significant change. Group 2: Fourteen of 24 PCG eyes (58%) demonstrated cupping reversal, with preoperative vs postoperative mean IOP 36.1 ± 8.9 mm Hg vs 13.3 ± 2.1 mm Hg (P < .00001). Two eyes had thin RNFL postoperatively despite healthy-appearing ONH. Postoperative RNFL showed statistically significant linear correlation with preoperative (but not postoperative) cup-to-disc ratio. Limitations include small numbers, few reliable Humphrey visual fields, and absent preoperative imaging (Group 2). Some eyes with IOP reduction and ONH cupping reversal show continued RNFL thinning postoperatively. The preoperative ONH cup-to-disc ratio predicted the postoperative RNFL better than the postoperative "reversed and smaller" cup-to-disc ratio. Cupping reversal in pediatric glaucoma may not predict improved ONH health and deserves further study. Copyright © 2014 Elsevier Inc. All rights reserved.
Shin, Hye-Young; Park, Hae-Young Lopilly; Jung, Younhea; Choi, Jin-A; Park, Chan Kee
2014-10-01
To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Retrospective, observational study. A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic disc damage in early glaucoma. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Influence of optic disc leakage on objective optic nerve head assessment in patients with uveitis.
Heinz, Carsten; Kogelboom, Katy; Heiligenhaus, Arnd
2016-02-01
Secondary glaucoma is a common complication in patients with uveitis. Heidelberg Retina Tomography (HRT) and retinal nerve fiber layer (RNFL) thickness on optical coherence tomography (OCT) are widely used for examining optic nerve head changes. We evaluated these parameters in patients with uveitis and secondary glaucoma and with inflammatory papillary leakage on fluorescein angiography. Prospective single-center analysis of patients with uveitis, evaluating the impact of optic disc leakage on objective optic disc imaging parameters. Overall, 96 eyes of 59 patients were included. Papillary leakage was found in 42 eyes (43.8 %), and secondary glaucoma was found in 41 eyes (42.7 %). Glaucoma and papillary leakage were present in 12 (29 %) eyes with leakage and in 29 (54 %) eyes without leakage (p = 0.023). Neuroretinal rim area (p = 0.004), rim volume on HRT (p = 0.004), and RNFL thickness on OCT (p = 0.0008) were significantly increased in eyes with papillary leakage, while RNFL on HRT was unchanged (p = 0.255). When only eyes with normal IOP were examined, all objective parameters on OCT and HRT were significantly increased, whereas in eyes with secondary glaucoma, there was only a trend in the same direction, which did not reach significance. A comparison of eyes with secondary glaucoma and optic disc leakage to normal eyes with no glaucoma or leakage revealed no difference in any of the parameters. The objective parameters of optic nerve head imaging tools are significantly influenced by papillary leakage. In patients with secondary glaucoma and papillary leakage, these techniques are unable to detect and monitor glaucomatous damage.
Ahn, J; Yun, I S; Yoo, H G; Choi, J-J; Lee, M
2017-01-01
Purpose To evaluate a progression-detecting algorithm for a new automated matched alternation flicker (AMAF) in glaucoma patients. Methods Open-angle glaucoma patients with a baseline mean deviation of visual field (VF) test>−6 dB were included in this longitudinal and retrospective study. Functional progression was detected by two VF progression criteria and structural progression by both AMAF and conventional comparison methods using optic disc and retinal nerve fiber layer (RNFL) photography. Progression-detecting performances of AMAF and the conventional method were evaluated by an agreement between functional and structural progression criteria. RNFL thickness changes measured by optical coherence tomography (OCT) were compared between progressing and stable eyes determined by each method. Results Among 103 eyes, 47 (45.6%), 21 (20.4%), and 32 (31.1%) eyes were evaluated as glaucoma progression using AMAF, the conventional method, and guided progression analysis (GPA) of the VF test, respectively. The AMAF showed better agreement than the conventional method, using GPA of the VF test (κ=0.337; P<0.001 and κ=0.124; P=0.191, respectively). The rates of RNFL thickness decay using OCT were significantly different between the progressing and stable eyes when progression was determined by AMAF (−3.49±2.86 μm per year vs −1.83±3.22 μm per year; P=0.007) but not by the conventional method (−3.24±2.42 μm per year vs −2.42±3.33 μm per year; P=0.290). Conclusions The AMAF was better than the conventional comparison method in discriminating structural changes during glaucoma progression, and showed a moderate agreement with functional progression criteria. PMID:27662466
Peripapillary vessel density changes in Leber's Hereditary Optic Neuropathy: a new biomarker.
Balducci, Nicole; Cascavilla, Maria Lucia; Ciardella, Antonio; La Morgia, Chiara; Triolo, Giacinto; Parisi, Vincenzo; Bandello, Francesco; Sadun, Alfredo A; Carelli, Valerio; Barboni, Piero
2018-05-22
The contribution of the microvascular supply to the pathogenesis of Leber's Hereditary Optic Neuropathy (LHON) is poorly understood. We aimed at measuring the peripapillary capillary vessel density (VD) using optical coherence tomography angiography (OCT-A) at different stages of LHON. Prospective, cross-sectional, multicenter, observational study. Twenty-two LHON patients divided in 4 groups: unaffected mutation carriers (LHON-u); early subacute stage (LHON-e); late subacute stage (LHON-l); chronic stage (LHON-ch). OCT-A scans centered on the optic disc were obtained by spectral domain OCT system. VD, retinal nerve fiber layer (RNFL) and ganglion cell inner plexiform layer (GC-IPL) thickness were compared between groups. Significant VD changes were detected in every sector (p<0.0001). In LHON-e, the VD was reduced in the temporal sector compared with LHON-u and in the temporal and inferotemporal sectors compared with controls. In LHON-l, VD was reduced in whole, temporal, superotemporal and inferotemporal sectors compared with LHON-u and controls. In LHON-ch, the VD was reduced in all sectors compared to the other groups. An asynchronous pattern emerged in the temporal sector with VD changes occurring earlier than RNFL thickness changes and together with GC-IPL thinning. Significant peripapillary miscrovascular changes were detected over the different stages of LHON. Studying the vascular network separately from fibers revealed that microvascular changes in the temporal sector preceded the changes of RNFL and mirrored the GC-IPL changes. Measurements of the peripapillary vascular network may become a useful biomarker to monitor the disease process, evaluate therapeutic efficacy and elucidate pathophysiology. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Larrosa, José Manuel; Moreno-Montañés, Javier; Martinez-de-la-Casa, José María; Polo, Vicente; Velázquez-Villoria, Álvaro; Berrozpe, Clara; García-Granero, Marta
2015-10-01
The purpose of this study was to develop and validate a multivariate predictive model to detect glaucoma by using a combination of retinal nerve fiber layer (RNFL), retinal ganglion cell-inner plexiform (GCIPL), and optic disc parameters measured using spectral-domain optical coherence tomography (OCT). Five hundred eyes from 500 participants and 187 eyes of another 187 participants were included in the study and validation groups, respectively. Patients with glaucoma were classified in five groups based on visual field damage. Sensitivity and specificity of all glaucoma OCT parameters were analyzed. Receiver operating characteristic curves (ROC) and areas under the ROC (AUC) were compared. Three predictive multivariate models (quantitative, qualitative, and combined) that used a combination of the best OCT parameters were constructed. A diagnostic calculator was created using the combined multivariate model. The best AUC parameters were: inferior RNFL, average RNFL, vertical cup/disc ratio, minimal GCIPL, and inferior-temporal GCIPL. Comparisons among the parameters did not show that the GCIPL parameters were better than those of the RNFL in early and advanced glaucoma. The highest AUC was in the combined predictive model (0.937; 95% confidence interval, 0.911-0.957) and was significantly (P = 0.0001) higher than the other isolated parameters considered in early and advanced glaucoma. The validation group displayed similar results to those of the study group. Best GCIPL, RNFL, and optic disc parameters showed a similar ability to detect glaucoma. The combined predictive formula improved the glaucoma detection compared to the best isolated parameters evaluated. The diagnostic calculator obtained good classification from participants in both the study and validation groups.
Neuro-ophthalmologic evaluation, quality of life, and functional disability in patients with MS.
Garcia-Martin, Elena; Rodriguez-Mena, Diego; Herrero, Raquel; Almarcegui, Carmen; Dolz, Isabel; Martin, Jesus; Ara, Jose R; Larrosa, Jose M; Polo, Vicente; Fernández, Javier; Pablo, Luis E
2013-07-02
To evaluate correlations between longitudinal changes in neuro-ophthalmologic measures and quality of life (QOL) and disability in patients with multiple sclerosis (MS), using optical coherence tomography (OCT), visual evoked potentials (VEP), and visual field examination. Fifty-four patients with relapsing-remitting MS were enrolled in this study and underwent Multiple Sclerosis Quality of Life questionnaire (54 items) (MSQOL-54) and Expanded Disability Status Scale (EDSS) evaluation, as well as complete neuro-ophthalmologic examination including visual field testing and retinal nerve fiber layer (RNFL) measurements using Cirrus and Spectralis OCT and VEP. All patients were re-evaluated at 12, 24, and 36 months. Logistical regression was performed to analyze which measures, if any, could predict QOL. Overall, RNFL thickness results at the baseline evaluation were significantly different from those at 3 years (p ≤ 0.05), but there were no differences in functional measures (visual acuity, contrast sensitivity, color vision, visual field, and VEP). A reduced MSQOL-54 score was associated with an increase in EDSS score and a decrease in both functional and structural parameters. Patients with longer MS duration presented with a lower MSQOL-54 score (reduction in QOL). Patients with progressive axonal loss as seen in RNFL results had a lower QOL and more functional disability.
Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa
2014-01-01
The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss.
Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa
2014-01-01
Background The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Methods Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. Results No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. Conclusion In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss. PMID:24379653
Retinal nerve fiber layer thickness map and blood flow pulsation measured with SDOCT
NASA Astrophysics Data System (ADS)
Mujat, Mircea; Chan, Raymond C.; Cense, Barry; Pierce, Mark; Park, Hyle; Joo, Chulmin; Chen, Teresa C.; de Boer, Johannes F.
2006-02-01
Spectral-Domain Optical Coherence Tomography (SDOCT) allows for in-vivo video-rate investigation of biomedical tissue depth structure intended for non-invasive optical diagnostics. It has been suggested that OCT can be used for di-agnosis of glaucoma by measuring the thickness of the Retinal Nerve Fiber Layer (RNLF). We present an automated method for determining the RNFL thickness from a 3-D dataset based on edge detection using a deformable spline algo-rithm. The RNFL thickness map is combined with an integrated reflectance map and retinal cross-sectional images to provide the ophthalmologist with a familiar image for interpreting the OCT data. The video-rate capabilities of our SDOCT system allow for mapping the true retinal topography since motion artifacts are significantly reduced as com-pared to slower time-domain systems. Combined with Doppler Velocimetry, SDOCT also provides information on retinal blood flow dynamics. We analyzed the pulsatile nature of the bidirectional flow dynamics in an artery-vein pair for a healthy volunteer at different locations and for different blood vessel diameters. The Doppler phase shift is determined as the phase difference at the same point of adjacent depth profiles, and is integrated over the area delimited by two circles corresponding to the blood vessels location. Its temporal evolution clearly shows the blood flow pulsatile nature, the cardiac cycle, in both artery and vein. The artery is identified as having a stronger variation of the integrated phase shift. We observe that artery pulsation is always easily detectable, while vein pulsation seems to depend on the veins diameter.
Chen, Teresa C.
2009-01-01
Purpose: To demonstrate that video-rate spectral domain optical coherence tomography (SDOCT) can qualitatively and quantitatively evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) glaucomatous structural changes. To correlate quantitative SDOCT parameters with disc photography and visual fields. Methods: SDOCT images from 4 glaucoma eyes (4 patients) with varying stages of open-angle glaucoma (ie, early, moderate, late) were qualitatively contrasted with 2 age-matched normal eyes (2 patients). Of 61 other consecutive patients recruited in an institutional setting, 53 eyes (33 patients) met inclusion/exclusion criteria for quantitative studies. Images were obtained using two experimental SDOCT systems, one utilizing a superluminescent diode and the other a titanium:sapphire laser source, with axial resolutions of about 6 μm and 3 μm, respectively. Results: Classic glaucomatous ONH and RNFL structural changes were seen in SDOCT images. An SDOCT reference plane 139 μm above the retinal pigment epithelium yielded cup-disc ratios that best correlated with masked physician disc photography cup-disc ratio assessments. The minimum distance band, a novel SDOCT neuroretinal rim parameter, showed good correlation with physician cup-disc ratio assessments, visual field mean deviation, and pattern standard deviation (P values range, .0003–.024). RNFL and retinal thickness maps correlated well with disc photography and visual field testing. Conclusions: To our knowledge, this thesis presents the first comprehensive qualitative and quantitative evaluation of SDOCT images of the ONH and RNFL in glaucoma. This pilot study provides basis for developing more automated quantitative SDOCT-specific glaucoma algorithms needed for future prospective multicenter national trials. PMID:20126502
Lamparter, Julia; Schmidtmann, Irene; Schuster, Alexander K; Siouli, Angeliki; Wasielica-Poslednik, Joanna; Mirshahi, Alireza; Höhn, René; Unterrainer, Josef; Wild, Philipp S; Binder, Harald; Lackner, Karl; Beutel, Manfred E; Münzel, Thomas; Pfeiffer, Norbert; Hoffmann, Esther M
2018-01-01
Glaucoma is a neurodegenerative disease, leading to thinning of the retinal nerve fibre layer (RNFL). The exact influence of ocular, cardiovascular, morphometric, lifestyle and cognitive factors on RNFL thickness (RNFLT) is unknown and was analysed in a subgroup of the Gutenberg Health Study (GHS). Global peripapillary RNFLT was measured in 3224 eyes of 1973 subjects (49% female) using spectral-domain optical coherence tomography (SD-OCT). The association of age, sex, ocular, cardiovascular, morphometric, lifestyle and cognitive factors on RNFLT was analysed using Pearson correlation coefficient and fitting a linear mixed model. In the univariable analysis highest correlations were found for axial length (r = -0.27), spherical equivalent (r = 0.24), and glaucoma (r = -0.15) (p<0.0001, respectively). Other significant correlations with RNFLT were found for age, sex, intraocular pressure, systemic hypertension and systolic blood pressure, previous eye surgery, cholesterol, homocysteine, history of coronary artery disease, history of myocardial infarction, apnoea, diabetes and alcohol intake, p<0.05, respectively. Body length, body weight, BMI, diastolic blood pressure, blood glucose, HbA1c, history of apoplexy, cognitive function, peripheral artery disease, tinnitus, migraine, nicotine intake, central corneal thickness, and pseudophakia were not significantly correlated with RNFLT. The regression model revealed a significant relationship between RNFLT and age in decades (p<0.02), spherical equivalent (p<0.0001), axial length (p<0.0001), glaucoma (p<0.0001), tinnitus (p = 0.04), apnoea (p = 0.047), homocysteine (p = 0.05) and alcohol intake >10g/d for women and >20g/d for men (p = 0.02). Glaucoma, apnoea, higher homocysteine, higher alcohol intake and higher axial length as well as age were related to decreased RNFLT while higher spherical equivalent or history for tinnitus were related to thicker RNFL. RNFLT is related to age, ocular parameters and lifestyle factors. Considering these parameters in normative databases could improve the evaluation of peripapillary RNFLT. It is necessary to evaluate if a reduction of alcohol intake as well as the therapy of apnea or high homocysteine levels could positively influence RNFLT.
NASA Astrophysics Data System (ADS)
Alluwimi, Muhammed Saad
Glaucoma is the second leading cause of the blindness worldwide. It is a group of chronic, progressive, and potentially blinding optic neuropathies characterized by abnormalities of the optic nerve head and/or retinal nerve fiber layer (RNFL) associated with visual field abnormality. When diagnosing and managing patients with glaucoma, clinicians evaluate the agreement between structural and functional measures. However, it has been widely recognized that there is often a discordance between structural and functional (e.g., perimetry) measures in glaucoma, posing a challenge for clinicians to make their decisions. As explained in the literature, this discordance may relate to high normal between-subject variation, insufficient knowledge of the RNFL bundle organization, sparse spacing of the perimetric locations used to measure the functional performance of ganglion cells, high test-retest variation for the most commonly used stimulus for perimetry, and poor perimetric sampling of the macula. The aim of this thesis was to overcome this discordance by conducting three experiments: First, asymmetry analysis was used to reduce between-subject variation of the macular thickness and ganglion cell thickness measurements with OCT. This variation was decreased at particular regions of the macula. Outside the macula, the variation remained high leading to the second experiment in which customized closely-spaced perimetric locations were presented at wedge defects, guided by the OCT en face images of the RNFL bundles. A rapid suprathreshold perimetric strategy was used and perimetric defect was, in most cases, in correspondence with the structural defect. To threshold perimetric defects, an elongated blur-resistant stimulus was oriented within damaged RNFL bundles. It was found that contrast sensitivities were below the 95% normal limit in 37 of 44 locations. The latter experiment focused on wedge defects outside the macula, which led to the third experiment in which the goal was to investigate the feasibility of a basis to individualize perimetric locations within the macula guided by structural damage seen on OCT en face images. In preliminary data, it was feasible to individualize perimetric locations within the macula. In this thesis, the agreement between structural and functional measures was improved in glaucoma, by developing methods and techniques that provided a framework to help overcome challenges in clinical decision making.
Riga, Fryni; Georgalas, Ilias; Tsikripis, Panagiotis; Papaconstantinou, Dimitrios
2014-01-01
To compare and evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina tomography (HRT) to visual field (VF) parameters in normal and in patients with pseudoexfoliation with or without increased intraocular pressure (IOP). A total of 96 subjects were included in our study aged between 65 years and 78 years. The normal group consisted of 28 subjects (14 men and 14 women). Out of the total number of patients, 68 patients who showed pseudoexfoliation (21 men and 47 women) were divided into two groups. Of these, the first group had pseudoexfoliation with increased IOP and the second group showed deposits of pseudoexfoliative material without an increase in IOP. The normal controls were randomly chosen and restricted to those without any glaucomatous optic disc damages, VF defects, and an IOP <15 mmHg. All subjects were prospectively included for repeated measurements of IOP, OCT, HRT, and VFs during the same visit by the same examiner and all measurements were repeated every 3 months. Mean RNFL thickness measured by OCT was larger in the normal controls than in the other two groups (98.04 μm (first group) vs 75.42 μm and 97.02 μm (second group), P<0.05). Four-quadrant RNFL thickness measurements were significantly different between the normal and the group 1 (P<0.05) but not with the group 2 (P>0.05). Rim area had a mean difference of -0.44, whereas cup-to-disc ratio (C/D) showed a mean difference of 0.31, thus being significantly different between the normal and the two groups (all P<0.05). The median of the mean deviation parameter of VFs was -0.28 for the normal vs -0.32 and -0.18 for the other two groups, whereas pattern standard deviation median difference was 0.89 for the normal and 1.32 and 1.20 for the other two groups, respectively (P<0.05). Both OCT and HRT showed early ONH and RNFL changes in their parameters and did not correlate with the normal findings of the automated perimetry.
Riga, Fryni; Georgalas, Ilias; Tsikripis, Panagiotis; Papaconstantinou, Dimitrios
2014-01-01
Purpose To compare and evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) measurements obtained with the optical coherence tomography (OCT) and the Heidelberg retina tomography (HRT) to visual field (VF) parameters in normal and in patients with pseudoexfoliation with or without increased intraocular pressure (IOP). Methods A total of 96 subjects were included in our study aged between 65 years and 78 years. The normal group consisted of 28 subjects (14 men and 14 women). Out of the total number of patients, 68 patients who showed pseudoexfoliation (21 men and 47 women) were divided into two groups. Of these, the first group had pseudoexfoliation with increased IOP and the second group showed deposits of pseudoexfoliative material without an increase in IOP. The normal controls were randomly chosen and restricted to those without any glaucomatous optic disc damages, VF defects, and an IOP <15 mmHg. All subjects were prospectively included for repeated measurements of IOP, OCT, HRT, and VFs during the same visit by the same examiner and all measurements were repeated every 3 months. Results Mean RNFL thickness measured by OCT was larger in the normal controls than in the other two groups (98.04 μm (first group) vs 75.42 μm and 97.02 μm (second group), P<0.05). Four-quadrant RNFL thickness measurements were significantly different between the normal and the group 1 (P<0.05) but not with the group 2 (P>0.05). Rim area had a mean difference of −0.44, whereas cup-to-disc ratio (C/D) showed a mean difference of 0.31, thus being significantly different between the normal and the two groups (all P<0.05). The median of the mean deviation parameter of VFs was −0.28 for the normal vs −0.32 and −0.18 for the other two groups, whereas pattern standard deviation median difference was 0.89 for the normal and 1.32 and 1.20 for the other two groups, respectively (P<0.05). Conclusion Both OCT and HRT showed early ONH and RNFL changes in their parameters and did not correlate with the normal findings of the automated perimetry. PMID:25506206
Evaluation of a New Scoring System for Retinal Nerve Fiber Layer Photography Using HRA1 in 964 Eyes
Hong, Samin; Moon, Jong Wook; Ha, Seung Joo; Kim, Chan Yun; Seong, Gong Je
2007-01-01
Purpose To evaluate retinal nerve fiber layer (RNFL) defect by a new scoring system for RNFL photography using the Heidelberg Retina Angiograph 1 (HRA1). Methods This retrospective study included 128 healthy eyes and 836 primary open-angle glaucoma eyes. The RNFL photography using HRA1 was interpreted using a new scoring system, and correlated with visual field indices of standard automated perimetry (SAP). Using the presence of RNFL defect, darkness, width, and location, we established the new scoring system of RNFL photos. Results The mean RNFL defect score I in the early, moderate, severe, and control groups were 7.3, 9.2, 10.4, and 3.6, respectively. The mean RNFL defect score II in the early, moderate, severe, and control groups were 14.5, 28.5, 43.4, and 3.4, respectively. Correlations between the RNFL defect score II and the mean deviation of SAP was the strongest of the various combinations (r=-0.675, P<.001). Conclusions Using a new scoring system, we propose a method for semi-quantitative interpretation of RNFL photographs. This scoring system may be helpful to distinguish between normal and glaucomatous eyes, and the score is associated with the severity of visual field loss. PMID:18063886
Ocular findings in coal miners diagnosed with pneumoconiosis.
Ayar, Orhan; Orcun Akdemir, Mehmet; Erboy, Fatma; Yazgan, Serpil; Hayri Ugurbas, Suat
2017-06-01
Our study aimed at evaluating ocular findings and structural changes in coal mine workers who were chronically exposed to coal mine dust and diagnosed with pneumoconiosis. Ocular findings of 161 eyes of 81 patients diagnosed with pneumoconiosis who had previously worked or are currently working in coal mines were analyzed. Forty-six coal mine workers and sex matched healthy people (n = 20) participated in the study. Workers who had early changes of pneumoconiosis were included in Group 1 (n = 17), workers diagnosed with pneumoconiosis were included in Group 2 (n = 29), and healthy subjects were included in Group 3 (n = 20). Outcome measures were the difference in peripapillary retinal nerve fiber layer (RNFL) thickness, choroidal thickness (CT), central macular thickness (CMT) and tear function tests between the groups. RNFL thickness values in Group 1 and 2 were lower than in Group 3, the control group, in all quadrants except the temporal quadrant. However, there was no statistically significant difference in peripapillary RNFL thickness values in any quadrants among the three groups (p > 0.05). Central subfoveal choroidal thickness and CMT measurements were thinner in Group 1 and 2 than in the control group. However, this difference among groups was not statistically significant (p > 0.05). Mean schirmer's test result was 8.8 ± 1.6 mm in group 1, 7.1 ± 1.8 mm in Group 2 and 11.5 ± 3.6 mm in the control group. Mean tear break up time (BUT) test result was 7.1 ± 1.3 seconds (sec) in Group 1, 6.5 ± 1.8 sec in Group 2 and 10.4 ± 2.9 s in the control group. The Schirmer's test and BUT test results were both statistically significantly lower in coal mine workers (Group 1 and 2) compared to the control group. Group 1 and Group 2 did not show statistically significant difference in terms of Schirmer's test and BUT test results. The association between pneumoconiosis and coal mine dust contiguity is thought to be due to the effect of coal dust by producing chronic inflammation. In addition, there are several trace elements in coal dust which are toxic to vital tissues. In this study, ocular findings suggest that systemic levels of trace elements and chronic inflammation may not reach to a level that influences ocular structures. Nonetheless, tear functions seem to be affected in coal mine workers. This study suggests that the systemic effect of coal mine dust in ocular structures is not evident. However, direct contact with coal mine and fume leads to a decrease in tear function tests.
Peripapillary schisis in open-angle glaucoma.
Dhingra, N; Manoharan, R; Gill, S; Nagar, M
2017-03-01
PurposeTo report clinical features, topographic findings and outcome of 10 eyes with peripapillary schisis in open-angle glaucoma.Patients and methodsA retrospective review of patients with open-angle glaucoma who were noted to have peripapillary schisis on optical coherence tomography (OCT) were included. Serial peripapillary and macula infrared and OCT images, visual acuity, visual fields, and schisis appearance were reviewed.ResultsTen eyes of nine patients with open-angle glaucoma were detected to have the presence of peripapillary schisis. Nerve fibre layer schisis was detected in all eyes and one eye had an associated macular schisis. None of the eyes had an acquired pit of the optic nerve or pathological myopia. The mean intraocular pressures at detection was 18.3±4.3 mm Hg and the schisis resolved in four eyes after a mean follow-up of 21.2±8.8 months. Visual field worsening was noted in 4 of the 10 eyes and the resolution of schisis resulted in significant reduction in the retinal nerve fibre layer (RNFL) thickness.ConclusionsPeripapillary schisis detected during the normal course of open-angle glaucoma can resolve spontaneously and rarely involves the macula. Its resolution leads to reduction in RNFL thickness; therefore, caution is advised while interpreting serial scans.
Garcia-Martin, Elena; Pueyo, Victoria; Almarcegui, Carmen; Martin, Jesus; Ara, Jose R; Sancho, Eva; Pablo, Luis E; Dolz, Isabel; Fernandez, Javier
2011-11-01
To quantify structural and functional degeneration in the retinal nerve fibre layer (RNFL) of patients with multiple sclerosis (MS) over a 2-year time period, and to analyse the effect of prior optic neuritis (ON) as well as the duration and incidence of MS relapses. 166 MS patients and 120 healthy controls underwent assessment of visual acuity and colour vision, visual field examination, optical coherence tomography, scanning laser polarimetry and visual evoked potentials (VEPs). All subjects were re-evaluated after a period of 12 and 24 months. Changes in the optic nerve were detected by structural measurements but not by functional assessments. Changes registered in MS patients were greater than changes in healthy controls (p<0.05). Eyes with previous ON showed a greater reduction of parameters in the baseline evaluation, but RNFL atrophy was not significantly greater in the longitudinal study. Patients with MS relapses showed a greater reduction of RNFL thickness and VEP amplitude compared with non-relapsing cases. Patients with and without treatment showed similar measurement reduction, but the non-treated group had a significantly higher increase in Expanded Disability Status Scale (p=0.029). MS causes progressive axonal loss in the optic nerve, regardless of a history of ON. This ganglion cell atrophy occurs in all eyes but is more marked in MS eyes than in healthy eyes.
The structure and function of the macula in patients with advanced retinitis pigmentosa.
Vámos, Rita; Tátrai, Erika; Németh, János; Holder, Graham E; DeBuc, Delia Cabrera; Somfai, Gábor Márk
2011-10-28
To assess the structure and function of the macula in advanced retinitis pigmentosa (RP). Twenty-nine eyes of 22 patients with RP were compared against 17 control eyes. Time-domain optical coherence tomography (OCT) data were processed using OCTRIMA (optical coherence tomography retinal image analysis) as a means of quantifying commercial OCT system images. The thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer and outer plexiform layer complex (INL+OPL), and the outer nuclear layer (ONL) were measured. Multifocal electroretinography (mfERG) was performed; two groups were formed based on the mfERG findings. Fourteen eyes had no detectable central retinal function (NCRF) on mfERG; detectable but abnormal retinal function (DRF) was present in the mfERG of the other 15 eyes. The thickness of the ONL in the central macular region was significantly less in the NCRF eyes compared with that in both DRF eyes and controls. The ONL was significantly thinner in the pericentral region in both patient groups compared with that in controls, whereas the thickness of the GCL+IPL and INL+OPL was significantly decreased only in the NCRF eyes. The RNFL in the peripheral region was significantly thicker, whereas the thickness of the GCL+IPL and ONL was significantly thinner in both patient groups compared with that in controls. The results are consistent with degeneration of the outer retina preceding inner retinal changes in RP. OCT image segmentation enables objective evaluation of retinal structural changes in RP, with potential use in the planning of therapeutic interventions and conceivably as an outcome measure.
The Structure and Function of the Macula in Patients with Advanced Retinitis Pigmentosa
Vámos, Rita; Tátrai, Erika; Németh, János; Holder, Graham E.; DeBuc, Delia Cabrera
2011-01-01
Purpose. To assess the structure and function of the macula in advanced retinitis pigmentosa (RP). Methods. Twenty-nine eyes of 22 patients with RP were compared against 17 control eyes. Time-domain optical coherence tomography (OCT) data were processed using OCTRIMA (optical coherence tomography retinal image analysis) as a means of quantifying commercial OCT system images. The thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer and outer plexiform layer complex (INL+OPL), and the outer nuclear layer (ONL) were measured. Multifocal electroretinography (mfERG) was performed; two groups were formed based on the mfERG findings. Fourteen eyes had no detectable central retinal function (NCRF) on mfERG; detectable but abnormal retinal function (DRF) was present in the mfERG of the other 15 eyes. Results. The thickness of the ONL in the central macular region was significantly less in the NCRF eyes compared with that in both DRF eyes and controls. The ONL was significantly thinner in the pericentral region in both patient groups compared with that in controls, whereas the thickness of the GCL+IPL and INL+OPL was significantly decreased only in the NCRF eyes. The RNFL in the peripheral region was significantly thicker, whereas the thickness of the GCL+IPL and ONL was significantly thinner in both patient groups compared with that in controls. Conclusions. The results are consistent with degeneration of the outer retina preceding inner retinal changes in RP. OCT image segmentation enables objective evaluation of retinal structural changes in RP, with potential use in the planning of therapeutic interventions and conceivably as an outcome measure. PMID:21948552
Ayyildiz, Onder; Kucukevcilioglu, Murat; Ozge, Gokhan; Koylu, Mehmet Talay; Ozgonul, Cem; Gokce, Gokcen; Mumcuoglu, Tarkan; Durukan, Ali Hakan; Mutlu, Fatih Mehmet
2016-05-01
To compare peripapillary choroidal thickness (PP-CT) measurements using a spectral domain optical coherence tomography (SD-OCT) device with and without enhanced depth imaging (EDI). Sixty healthy subjects aged from 18 to 40 years were included in this study. PP-CTs were measured in the right eyes by manual segmentation via SD-OCT both with and without EDI. The intraclass correlation coefficient (ICC) for each technique and comparison of PP-CT measurements between two techniques were evaluated. The correlation between retinal nerve fiber layer (RNFL) thickness and PP-CT was also explored on images of SD-OCT without EDI. The PP-CT measurements of 55 subjects were evaluated. The ICC was 0.999 (95% CI: 0.998-1.0, p < 0.001) for SD-OCT with EDI and 0.996 (95% CI: 0.995-0.997, p < 0.001) for SD-OCT without EDI. The mean PP-CT measurements in all regions and the overall mean PP-CT measurements between the two techniques were not different (p > 0.05). Additionally, there was no correlation between RNFL thickness and PP-CT (r = -0.109; p = 0.335). The PP-CT measurements via SD-OCT without EDI were consistent with the measurements via SD-OCT with EDI. Ophthalmologists who do not have access to EDI technology can use images of SD-OCT without EDI to measure the peripapillary choroid for research purposes. However, thicker peripapillary choroids cannot be measured using this technique and require further modifications or newer technologies, such as SD-OCT with EDI.
Fanihagh, Farsad; Kremmer, Stephan; Anastassiou, Gerasimos; Schallenberg, Maurice
2015-01-01
To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO). 114 eyes of patients with moderate open angle glaucoma underwent spectral domain OCT (Topcon SD-OCT 2000 and Zeiss Cirrus HD-OCT), SLP (GDx VCC and GDx Pro) and CSLO (Heidelberg Retina Tomograph, HRT 3). Correlation coefficients were calculated between the structural parameters yielded by these examinations. The quantitative relationship between the measured RNFL thickness globally and for the four regions (superior, inferior, nasal, temporal) were evaluated with different regression models for all used imaging systems. The strongest correlation of RNFL measurements was found between devices using the same technology like GDx VCC and GDx Pro as well as Topcon OCT and Cirrus OCT. In glaucoma patients, the strongest associations (R²) were found between RNFL measurements of the two optical coherence tomography devices Topcon OCT and Cirrus OCT (R² = 0.513) and between GDx VCC and GDx Pro (R² = 0.451). The results of the OCTs and GDX Pro also had a strong quantitative relationship (Topcon OCT R² = 0.339 and Cirrus OCT R² = 0.347). GDx VCC and the OCTs showed a mild to moderate association (Topcon OCT R² = 0.207 and Cirrus OCT R² = 0.258). The confocal scanning laser ophthalmoscopy (HRT 3) had the lowest association to all other devices (Topcon OCT R² = 0.254, Cirrus OCT R² = 0.158, GDx Pro R² = 0.086 and GDx VCC R² = 0.1). The measurements of the RNFL in glaucoma patients reveal a high correlation of OCT and GDx devices because OCTs can measure all major retinal layers and SLP can detect nerve fibers allowing a comparison between the results of this devices. However, CSLO by means of HRT topography can only measure height values of the retinal surface but it cannot distinguish between different retinal layers. This may explain the rather poor correlations and associations between CSLO measurements and those of all other imaging devices which makes it difficult to compare HRT 3 nerve fiber data. These correlations are important in clinical routine especially when different techniques are used in the follow-up of glaucoma patients.
Age-Related Alterations in the Retinal Microvasculature, Microcirculation, and Microstructure.
Wei, Yantao; Jiang, Hong; Shi, Yingying; Qu, Dongyi; Gregori, Giovanni; Zheng, Fang; Rundek, Tatjana; Wang, Jianhua
2017-07-01
To characterize age-related alterations in the retinal microcirculation, microvascular network, and microstructure in healthy subjects. Seventy-four healthy subjects aged from 18 to 82 years were recruited and divided into four age groups (G1 with age <35 years, G2 with age 35 ∼ 49 years, G3 with age 50 ∼ 64 years, and G4 with age ≥65 years). Custom ultra-high resolution optical coherence tomography (UHR-OCT) was used to acquire six intraretinal layers of the macula. OCT angiography (OCTA) was used to image the retinal microvascular network. The retinal blood flow velocity (BFV) was measured using a Retinal Function Imager (RFI). Compared to G1, G2 had significant thinning of the retinal nerve fiber layer (RNFL) (P < 0.05), while G3 had thinning of the RNFL and ganglion cell and inner plexiform layer (GCIPL) (P < 0.05), in addition to thickening of the outer plexiform layer (OPL) and photoreceptor layer (PR) (P < 0.05). G4 had loss in retinal vessel density, thinning in RNFL and GCIPL, and decrease in venular BFV, in addition to thickening of the OPL and PR (P < 0.05). Age was negatively related to retinal vessel densities, the inner retinal layers, and venular BFV (P < 0.05). By contrast, age was positively related to OPL and PR (P < 0.05). During aging, decreases in retinal vessel density, inner retinal layer thickness, and venular BFV were evident and impacted each other as observed by simultaneous changes in multiple retinal components.
Compromised Integrity of Central Visual Pathways in Patients With Macular Degeneration.
Malania, Maka; Konrad, Julia; Jägle, Herbert; Werner, John S; Greenlee, Mark W
2017-06-01
Macular degeneration (MD) affects the central retina and leads to gradual loss of foveal vision. Although, photoreceptors are primarily affected in MD, the retinal nerve fiber layer (RNFL) and central visual pathways may also be altered subsequent to photoreceptor degeneration. Here we investigate whether retinal damage caused by MD alters microstructural properties of visual pathways using diffusion-weighted magnetic resonance imaging. Six MD patients and six healthy control subjects participated in the study. Retinal images were obtained by spectral-domain optical coherence tomography (SD-OCT). Diffusion tensor images (DTI) and high-resolution T1-weighted structural images were collected for each subject. We used diffusion-based tensor modeling and probabilistic fiber tractography to identify the optic tract (OT) and optic radiations (OR), as well as nonvisual pathways (corticospinal tract and anterior fibers of corpus callosum). Fractional anisotropy (FA) and axial and radial diffusivity values (AD, RD) were calculated along the nonvisual and visual pathways. Measurement of RNFL thickness reveals that the temporal circumpapillary retinal nerve fiber layer was significantly thinner in eyes with macular degeneration than normal. While we did not find significant differences in diffusion properties in nonvisual pathways, patients showed significant changes in diffusion scalars (FA, RD, and AD) both in OT and OR. The results indicate that the RNFL and the white matter of the visual pathways are significantly altered in MD patients. Damage to the photoreceptors in MD leads to atrophy of the ganglion cell axons and to corresponding changes in microstructural properties of central visual pathways.
Oh, Jong-Hyun
2009-01-01
Purpose To compare the ability of scanning laser polarimetry with variable corneal compensation (GDx-VCC) and Stratus optical coherence tomography (OCT) to detect photographic retinal nerve fiber layer (RNFL) defects. Methods This retrospective cross-sectional study included 45 eyes of 45 consecutive glaucoma patients with RNFL defects in red-free fundus photographs. The superior and inferior temporal quadrants in each eye were included for data analysis separately. The location and presence of RNFL defects seen in red-free fundus photographs were compared with those seen in GDx-VCC deviation maps and OCT RNFL analysis maps for each quadrant. Results Of the 90 quadrants (45 eyes), 31 (34%) had no apparent RNFL defects, 29 (32%) had focal RNFL defects, and 30 (33%) had diffuse RNFL defects in red-free fundus photographs. The highest agreement between GDx-VCC and red-free photography was 73% when we defined GDx-VCC RNFL defects as a cluster of three or more color-coded squares (p<5%) along the traveling line of the retinal nerve fiber in the GDx-VCC deviation map (kappa value, 0.388; 95% confidence interval (CI), 0.195 to 0.582). The highest agreement between OCT and red-free photography was 85% (kappa value, 0.666; 95% CI, 0.506 to 0.825) when a value of 5% outside the normal limit for the OCT analysis map was used as a cut-off value for OCT RNFL defects. Conclusions According to the kappa values, the agreement between GDx-VCC deviation maps and red-free photography was poor, whereas the agreement between OCT analysis maps and red-free photography was good. PMID:19794943
Validation of the UNC OCT Index for the Diagnosis of Early Glaucoma
Lee, Gary; Budenz, Donald L.; Warren, Joshua L.; Wall, Michael; Artes, Paul H.; Callan, Thomas M.; Flanagan, John G.
2018-01-01
Purpose To independently validate the performance of the University of North Carolina Optical Coherence Tomography (UNC OCT) Index in diagnosing and predicting early glaucoma. Methods Data of 118 normal subjects (118 eyes) and 96 subjects (96 eyes) with early glaucoma defined as visual field mean deviation (MD) greater than −4 decibels (dB), aged 40 to 80 years, and who were enrolled in the Full-Threshold Testing Size III, V, VI comparison study were used in this study. CIRRUS OCT average and quadrants' retinal nerve fiber layer (RNFL); optic disc vertical cup-to-disc ratio (VCDR), cup-to-disc area ratio, and rim area; and average, minimum, and six sectoral ganglion cell-inner plexiform layer (GCIPL) measurements were run through the UNC OCT Index algorithm. Area under the receiver operating characteristic curve (AUC) and sensitivities at 95% and 99% specificity were calculated and compared between single parameters and the UNC OCT Index. Results Mean age was 60.1 ± 11.0 years for normal subjects and 66.5 ± 8.1 years for glaucoma patients (P < 0.001). MD was 0.29 ± 1.04 dB and −1.30 ± 1.35 dB in normal and glaucomatous eyes (P < 0.001), respectively. The AUC of the UNC OCT Index was 0.96. The best single metrics when compared to the UNC OCT Index were VCDR (0.93, P = 0.054), average RNFL (0.92, P = 0.014), and minimum GCIPL (0.91, P = 0.009). The sensitivities at 95% and 99% specificity were 85.4% and 76.0% (UNC OCT Index), 71.9% and 62.5% (VCDR, all P < 0.001), 64.6% and 53.1% (average RNFL, all P < 0.001), and 66.7% and 58.3% (minimum GCIPL, all P < 0.001), respectively. Conclusions The findings confirm that the UNC OCT Index may provide improved diagnostic perforce over that of single OCT parameters and may be a good tool for detection of early glaucoma. Translational Relevance The UNC OCT Index algorithm may be incorporated easily into routine clinical practice and be useful for detecting early glaucoma. PMID:29629238
Validation of the UNC OCT Index for the Diagnosis of Early Glaucoma.
Mwanza, Jean-Claude; Lee, Gary; Budenz, Donald L; Warren, Joshua L; Wall, Michael; Artes, Paul H; Callan, Thomas M; Flanagan, John G
2018-04-01
To independently validate the performance of the University of North Carolina Optical Coherence Tomography (UNC OCT) Index in diagnosing and predicting early glaucoma. Data of 118 normal subjects (118 eyes) and 96 subjects (96 eyes) with early glaucoma defined as visual field mean deviation (MD) greater than -4 decibels (dB), aged 40 to 80 years, and who were enrolled in the Full-Threshold Testing Size III, V, VI comparison study were used in this study. CIRRUS OCT average and quadrants' retinal nerve fiber layer (RNFL); optic disc vertical cup-to-disc ratio (VCDR), cup-to-disc area ratio, and rim area; and average, minimum, and six sectoral ganglion cell-inner plexiform layer (GCIPL) measurements were run through the UNC OCT Index algorithm. Area under the receiver operating characteristic curve (AUC) and sensitivities at 95% and 99% specificity were calculated and compared between single parameters and the UNC OCT Index. Mean age was 60.1 ± 11.0 years for normal subjects and 66.5 ± 8.1 years for glaucoma patients ( P < 0.001). MD was 0.29 ± 1.04 dB and -1.30 ± 1.35 dB in normal and glaucomatous eyes ( P < 0.001), respectively. The AUC of the UNC OCT Index was 0.96. The best single metrics when compared to the UNC OCT Index were VCDR (0.93, P = 0.054), average RNFL (0.92, P = 0.014), and minimum GCIPL (0.91, P = 0.009). The sensitivities at 95% and 99% specificity were 85.4% and 76.0% (UNC OCT Index), 71.9% and 62.5% (VCDR, all P < 0.001), 64.6% and 53.1% (average RNFL, all P < 0.001), and 66.7% and 58.3% (minimum GCIPL, all P < 0.001), respectively. The findings confirm that the UNC OCT Index may provide improved diagnostic perforce over that of single OCT parameters and may be a good tool for detection of early glaucoma. The UNC OCT Index algorithm may be incorporated easily into routine clinical practice and be useful for detecting early glaucoma.
Safety and efficacy of gas-forced infusion (air pump) in coaxial phacoemulsification.
Chaudhry, Prashaant; Prakash, Gaurav; Jacob, Soosan; Narasimhan, Smita; Agarwal, Sunita; Agarwal, Amar
2010-12-01
To evaluate the safety and efficacy of gas-forced infusion (air pump) in uncomplicated coaxial phacoemulsification. Dr. Agarwal's Eye Hospital, Chennai, India. Comparative case series. Specular microscopy and optical coherence tomography were used to analyze the endothelium, central macular thickness (CMT), and peripapillary retinal nerve fiber layer (RNFL) thickness before and approximately 1, 7, 30, and 90 days after coaxial phacoemulsification with (infusion group) or without (control group) gas-forced infusion. Surgical time, surge, phaco energy, irrigation fluid volume, surgical ease, complications, and visual gain in the 2 groups were compared. The mean endothelial cell loss was lower in the infusion group than in the control group (6.98% ± 8.46% [SD] versus 10.54% ± 11.24%; P = .045) and the irrigation/aspiration time significantly shorter (54 ± 39 seconds versus 105 ± 84 seconds; P = .0001). The surgery was rated as easier with gas-forced infusion (scale 1 to 10: mean 8.3 ± 2.1 versus 6.6 ± 1.6; P = .00002). However, the amount of irrigating fluid volume was higher in the infusion group (117 ± 37 mL versus 94 ± 41 mL; P = .003). No surge occurred in the infusion group; it occurred a mean of 3.00 ± 4.16 times in the control group (P<.0001). The rate of visual gain, CMT, peripapillary RNFL thickness, phaco time, and amount of phaco energy were comparable in the 2 groups. Gas-forced infusion was safe and effective in controlling surge and increased the safety, ease, and speed of coaxial phacoemulsification. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Age-Related Alterations in the Retinal Microvasculature, Microcirculation, and Microstructure
Wei, Yantao; Jiang, Hong; Shi, Yingying; Qu, Dongyi; Gregori, Giovanni; Zheng, Fang; Rundek, Tatjana; Wang, Jianhua
2017-01-01
Purpose To characterize age-related alterations in the retinal microcirculation, microvascular network, and microstructure in healthy subjects. Methods Seventy-four healthy subjects aged from 18 to 82 years were recruited and divided into four age groups (G1 with age <35 years, G2 with age 35 ∼ 49 years, G3 with age 50 ∼ 64 years, and G4 with age ≥65 years). Custom ultra-high resolution optical coherence tomography (UHR-OCT) was used to acquire six intraretinal layers of the macula. OCT angiography (OCTA) was used to image the retinal microvascular network. The retinal blood flow velocity (BFV) was measured using a Retinal Function Imager (RFI). Results Compared to G1, G2 had significant thinning of the retinal nerve fiber layer (RNFL) (P < 0.05), while G3 had thinning of the RNFL and ganglion cell and inner plexiform layer (GCIPL) (P < 0.05), in addition to thickening of the outer plexiform layer (OPL) and photoreceptor layer (PR) (P < 0.05). G4 had loss in retinal vessel density, thinning in RNFL and GCIPL, and decrease in venular BFV, in addition to thickening of the OPL and PR (P < 0.05). Age was negatively related to retinal vessel densities, the inner retinal layers, and venular BFV (P < 0.05). By contrast, age was positively related to OPL and PR (P < 0.05). Conclusions During aging, decreases in retinal vessel density, inner retinal layer thickness, and venular BFV were evident and impacted each other as observed by simultaneous changes in multiple retinal components. PMID:28744554
He, Lin; Yang, Hongli; Gardiner, Stuart K.; Williams, Galen; Hardin, Christy; Strouthidis, Nicholas G.; Fortune, Brad; Burgoyne, Claude F.
2014-01-01
Purpose. We determined if the detection of spectral-domain optical coherence tomography (SDOCT) optic nerve head (ONH) change precedes the detection of confocal scanning laser tomography (CSLT) ONH surface, SDOCT retinal nerve fiber layer (RNFL), scanning laser perimetry (SLP), and multifocal electroretinography (mfERG) change in eight experimental glaucoma (EG) eyes. Methods. Both eyes from eight monkeys were tested at least three times at baseline, and then every 2 weeks following laser-induced chronic unilateral IOP elevation. Event and trend-based definitions of onset in the control and EG eyes for 11 SDOCT neural and connective tissue, CSLT surface, SDOCT RNFL, SLP, and mfERG parameters were explored. The frequency and timing of onset for each parameter were compared using a logrank test. Results. Maximum post-laser IOP was 18 to 42 mm Hg in the EG eyes and 12 to 20 mm Hg in the control eyes. For event- and trend-based analyses, onsets were achieved earliest and most frequently within the ONH neural and connective tissues using SDOCT, and at the ONH surface using CSLT. SDOCT ONH neural and connective tissue parameter change preceded or coincided with CSLT ONH surface change in most EG eyes. The SDOCT and SLP measures of RNFL thickness, and mfERG measures of visual function demonstrated similar onset rates, but occurred later than SDOCT ONH and CSLT surface change, and in fewer eyes. Conclusions. SDOCT ONH change detection commonly precedes or coincides with CSLT ONH surface change detection, and consistently precedes RNFLT, SLP, and mfERG change detection in monkey experimental glaucoma. PMID:24255047
Schweitzer, Cedric; Korobelnik, Jean-Francois; Le Goff, Melanie; Rahimian, Olivier; Malet, Florence; Rougier, Marie-Benedicte; Delyfer, Marie-Noelle; Dartigues, Jean-Francois; Delcourt, Cecile
2016-11-01
To assess diagnostic accuracy of spectral-domain optical coherence tomography (SD-OCT) to discriminate glaucoma and control subjects in an elderly population. The antioxidants, essential lipids, nutrition and ocular maladies study (ALIENOR: "Antioxydants, Lipides Essentiels, Nutrition et Maladies Oculaires") is a population-based study. From 2009 to 2010, a total of 624 subjects, aged 74 years or older underwent a complete eye examination, including optic disc color photography and SD-OCT examination of the macula and the optic nerve head. Glaucoma diagnosis was made using retinophotography of the optic nerve head and International Society for Epidemiologic and Geographical Ophthalmology criteria. Average and sectorial peripapillary retinal nerve fiber layer thicknesses (RNFLT) were compared between glaucoma and control subjects using area under the receiver operating characteristic curves (AUC), positive and negative likelihood ratios (LR+/LR-), and diagnostic odds ratios (DOR). A total of 532 subjects had complete data, 492 were classified as controls and 40 were classified as glaucoma. Mean age was 82.1 ± 4.2 years and average RNFLT was significantly different between both groups (controls: 88.7 ± 12.2 μm, glaucoma: 65.4 ± 14.4 μm, P < 0.001). Highest AUC values were observed for average (0.895), temporal-inferior (0.874), and temporal-superior (0.868) RNFLT. Temporal-superior RNFLT had the highest DOR (25.31; LR+, 4.65; LR-, 0.18), followed by average RNFLT (DOR: 24.80; LR+, 6.36; LR-, 0.26). When using the normative database provided by the machine, DOR increased to 31.03 (LR+, 1.75; LR-, 0.06) if at least one parameter was considered abnormal (at P < 0.05). Parameters of SD-OCT RNFL may provide valuable information in a screening strategy to improve glaucoma detection in a general population of elderly people.
Shin, Joong Won; Lee, Jiyun; Kwon, Junki; Choi, Jaewan; Kook, Michael S
2017-12-01
To study whether there are global and regional relationships between peripapillary vascular density (pVD) assessed by optical coherence tomography angiography (OCT-A) and visual field (VF) mean sensitivity at different glaucoma stages. Microvascular images and peripapillary retinal nerve fibre layer (pRNFL) thicknesses were obtained using a Cirrus OCT-A device in 91 glaucoma subjects. The pVD was measured at various spatial locations according to the Garway-Heath map, using a MATLAB software (The MathWorks, Natick, Massachusetts). VF mean sensitivity (VFMS) was recorded in the 1/L scale. Global and regional vasculature-function (pVD vs VFMS) relationships were assessed in separate patient groups at mild and moderate-to-advanced stages of glaucoma. The pVDs at superotemporal and inferotemporal regions were significantly associated with corresponding VFMS in mild glaucoma (p<0.05). In moderate-to-advanced glaucoma, there were significant associations between pVD and VFMS, regardless of location. The association between global pVD and VFMS was significantly stronger than that between global pRNFL thickness and VFMS in moderate-to-advanced stage glaucoma (p <0.05). Global and regional pVD measured by OCT-A was significantly associated with corresponding VFMS in moderate-to-advanced glaucoma. OCT-A may be useful in monitoring glaucoma at various stages. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Corneal and Retinal Neuronal Degeneration in Early Stages of Diabetic Retinopathy.
Srinivasan, Sangeetha; Dehghani, Cirous; Pritchard, Nicola; Edwards, Katie; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2017-12-01
To examine the neuronal structural integrity of cornea and retina as markers for neuronal degeneration in nonproliferative diabetic retinopathy (NPDR). Participants were recruited from the broader Brisbane community, Queensland, Australia. Two hundred forty-one participants (187 with diabetes and 54 nondiabetic controls) were examined. Diabetic retinopathy (DR) was graded according to the Early Treatment Diabetic Retinopathy Study (ETDRS) scale. Corneal nerve fiber length (CNFL), corneal nerve branch density (CNBD), corneal nerve fiber tortuosity (CNFT), full retinal thickness, retinal nerve fiber layer (RNFL), ganglion cell complex (GCC), focal (FLV) and global loss volumes (GLV), hemoglobin A1c (HbA1c), nephropathy, neuropathy, and cardiovascular measures were examined. The central zone (P = 0.174), parafoveal thickness (P = 0.090), perifovea (P = 0.592), RNFL (P = 0.866), GCC (P = 0.798), and GCC GLV (P = 0.338) did not differ significantly between the groups. In comparison to the control group, those with very mild NPDR and those with mild NPDR had significantly higher focal loss in GCC volume (P = 0.036). CNFL was significantly lower in those with mild NPDR (P = 0.004) in comparison to the control group and those with no DR. The CNBD (P = 0.094) and CNFT (P = 0.458) did not differ between the groups. Both corneal and retinal neuronal degeneration may occur in early stages of diabetic retinopathy. Further studies are required to examine these potential markers for neuronal degeneration in the absence of clinical signs of DR.
Picconi, Fabiana; Parravano, Mariacristina; Ylli, Dorina; Pasqualetti, Patrizio; Coluzzi, Sara; Giordani, Ilaria; Malandrucco, Ilaria; Lauro, Davide; Scarinci, Fabio; Giorno, Paola; Varano, Monica; Frontoni, Simona
2017-05-01
Recent studies have identified neuroretinal abnormalities in persons affected by diabetes mellitus, before the onset of microvascular alterations. However, the role of glycemic variability (GV) on early retinal neurodegeneration is still not clarified. To explore the relationship between glycemic control and neuroretinal characteristics, 37 persons with Type 1 diabetes mellitus (Type 1 DM) divided into two groups with no signs (noRD) and with mild non-proliferative diabetic retinopathy (NPDR) compared to 13 healthy control participants (C) were recruited. All persons underwent an optical coherence tomography with automatic segmentation of all neuroretinal layers. Measurements of mean of nasal (N)/temporal (T)/superior (S)/inferior (I) macular quadrants for individual layer were also calculated. Metabolic control was evaluated by glycated hemoglobin (HbA1c), and indexes of GV were calculated from continuous glucose monitoring. The difference among the three groups in terms of RNFL thickness was significantly dependent on quadrant (F(6;132) = 2.315; p = 0.037). This interaction was due to a specific difference in RNFL-N thickness, where both Type 1 DM groups showed a similar reduction versus C (-3.9 for noDR and -4.9 for NPDR), without any relevant difference between them (-1.0). Inner nuclear layer (INL) was increased in all quadrants in the two Type 1 DM groups compared to C (mean difference = 7.73; 95% CI: 0.32-15.14, p = 0.043; mean difference = 7.74; 95% CI: 0.33-15.15, p = 0.043, respectively). A negative correlation between RNFL-N and low blood glucose index (r = -0.382, p = 0.034) and positive correlation between INL and continuous overall net glycemic action -1, -2, -4 h (r = 0.40, p = 0.025; r = 0.39, p = 0.031; r = 0.41, p = 0.021, respectively) were observed in Type 1 DM patients. The triglycerides were positively and significantly correlated to INL (r = 0.48, p = 0.011), in Type 1 DM subjects. GV and triglycerides resulted both independent predictors of increased INL thickness. No correlation was found with HbA1c. Early structural damage of neuroretina in persons with Type 1 DM patients is related to glucose fluctuations. GV should be addressed, even in the presence of a good metabolic control.
Serial Diffusion Tensor Imaging of the Optic Radiations after Acute Optic Neuritis.
Kolbe, Scott C; van der Walt, Anneke; Butzkueven, Helmut; Klistorner, Alexander; Egan, Gary F; Kilpatrick, Trevor J
2016-01-01
Previous studies have reported diffusion tensor imaging (DTI) changes within the optic radiations of patients after optic neuritis (ON). We aimed to study optic radiation DTI changes over 12 months following acute ON and to study correlations between DTI parameters and damage to the optic nerve and primary visual cortex (V1). We measured DTI parameters [fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), and mean diffusivity (MD)] from the optic radiations of 38 acute ON patients at presentation and 6 and 12 months after acute ON. In addition, we measured retinal nerve fibre layer thickness, visual evoked potential amplitude, optic radiation lesion load, and V1 thickness. At baseline, FA was reduced and RD and MD were increased compared to control. Over 12 months, FA reduced in patients at an average rate of -2.6% per annum (control = -0.51%; p = 0.006). Change in FA, RD, and MD correlated with V1 thinning over 12 months (FA: R = 0.450, p = 0.006; RD: R = -0.428, p = 0.009; MD: R = -0.365, p = 0.029). In patients with no optic radiation lesions, AD significantly correlated with RNFL thinning at 12 months (R = 0.489, p = 0.039). In conclusion, DTI can detect optic radiation changes over 12 months following acute ON that correlate with optic nerve and V1 damage.
Serial Diffusion Tensor Imaging of the Optic Radiations after Acute Optic Neuritis
van der Walt, Anneke; Butzkueven, Helmut; Klistorner, Alexander; Egan, Gary F.; Kilpatrick, Trevor J.
2016-01-01
Previous studies have reported diffusion tensor imaging (DTI) changes within the optic radiations of patients after optic neuritis (ON). We aimed to study optic radiation DTI changes over 12 months following acute ON and to study correlations between DTI parameters and damage to the optic nerve and primary visual cortex (V1). We measured DTI parameters [fractional anisotropy (FA), axial diffusivity (AD), radial diffusivity (RD), and mean diffusivity (MD)] from the optic radiations of 38 acute ON patients at presentation and 6 and 12 months after acute ON. In addition, we measured retinal nerve fibre layer thickness, visual evoked potential amplitude, optic radiation lesion load, and V1 thickness. At baseline, FA was reduced and RD and MD were increased compared to control. Over 12 months, FA reduced in patients at an average rate of −2.6% per annum (control = −0.51%; p = 0.006). Change in FA, RD, and MD correlated with V1 thinning over 12 months (FA: R = 0.450, p = 0.006; RD: R = −0.428, p = 0.009; MD: R = −0.365, p = 0.029). In patients with no optic radiation lesions, AD significantly correlated with RNFL thinning at 12 months (R = 0.489, p = 0.039). In conclusion, DTI can detect optic radiation changes over 12 months following acute ON that correlate with optic nerve and V1 damage. PMID:27555964
A basis for customising perimetric locations within the macula in glaucoma.
Alluwimi, Muhammed S; Swanson, William H; Malinovsky, Victor E; King, Brett J
2018-03-01
It has been recognised that the 24-2 grid used for perimetry may poorly sample the macula, which has been recently identified as a critical region for diagnosing and managing patients with glaucoma. We compared data derived from patients and controls to investigate the efficacy of a basis for customising perimetric locations within the macula, guided by en face images of retinal nerve fibre layer (RNFL) bundles. We used SD-OCT en face montages (www.heidelbergengineering.com) of the RNFL in 10 patients with glaucoma (ages 56-80 years, median 67.5 years) and 30 age-similar controls (ages 47-77, median 58). These patients were selected because of either the absence of perimetric defect while glaucomatous damage to the RNFL bundles was observed, or because of perimetric defect that did not reflect the extent and locations of the glaucomatous damage that appeared in the RNFL images. We used a customised blob stimulus for perimetric testing (a Gaussian blob with 0.25° standard deviation) at 10-2 grid locations, to assess the correspondence between perimetric defects and damaged RNFL bundles observed on en face images and perimetric defects. Data from the age-similar controls were used to compute total deviation (TD) and pattern deviation (PD) values at each location; a perimetric defect for a location was defined as a TD or PD value of -0.5 log unit or deeper. A McNemar's test was used to compare the proportions of locations with perimetric defects that fell outside the damaged RNFL bundles, with and without accounting for displacement of ganglion cell bodies. All patients but one had perimetric defects that were consistent with the patterns of damaged RNFL bundles observed on the en face images. We found six abnormal perimetric locations of 2040 tested in controls and 132 abnormal perimetric locations of 680 tested in patients. The proportions of abnormal locations that fell outside the damaged RNFL bundles, with and without accounting for displacement of the ganglion cell bodies were 0.08 and 0.07, respectively. The difference between the two proportions did not reach statistical significance (p = 0.5 for a one-tailed test). We demonstrated that it is effective to customise perimetric locations within the macula, guided by en face images of the RNFL bundles. The perimetric losses found with a 10-2 grid demonstrated similar patterns as the damaged RNFL bundles observed on the en face images. © 2018 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.
Iyigundogdu, Ilkin; Derle, Eda; Asena, Leyla; Kural, Feride; Kibaroglu, Seda; Ocal, Ruhsen; Akkoyun, Imren; Can, Ufuk
2018-02-01
Aim To compare the relationship between white matter hyperintensities (WMH) on brain magnetic resonance imaging and retinal nerve fiber layer (RNFL), choroid, and ganglion cell layer (GCL) thicknesses in migraine patients and healthy subjects. We also assessed the role of cerebral hypoperfusion in the formation of these WMH lesions. Methods We enrolled 35 migraine patients without WMH, 37 migraine patients with WMH, and 37 healthy control subjects examined in the Neurology outpatient clinic of our tertiary center from May to December 2015. RFNL, choroid, and GCL thicknesses were measured by optic coherence tomography. Results There were no differences in the RFNL, choroid, or GCL thicknesses between migraine patients with and without WMH ( p > 0.05). Choroid layer thicknesses were significantly lower in migraine patients compared to control subjects ( p < 0.05), while there were no differences in RFNL and GCL thicknesses ( p > 0.05). Conclusions The 'only cerebral hypoperfusion' theory was insufficient to explain the pathophysiology of WMH lesions in migraine patients. In addition, the thinning of the choroid thicknesses in migraine patients suggests a potential causative role for cerebral hypoperfusion and decreased perfusion pressure of the choroid layer.
Strouthidis, Nicholas G.; Fortune, Brad; Yang, Hongli; Sigal, Ian A.
2011-01-01
Purpose. To investigate whether longitudinal changes deep within the optic nerve head (ONH) are detectable by spectral domain optical coherence tomography (SDOCT) in experimental glaucoma (EG) and whether these changes are detectable at the onset of Heidelberg Retina Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany)–defined surface topography depression. Methods. Longitudinal SDOCT imaging (Spectralis; Heidelberg Engineering) was performed in both eyes of nine rhesus macaques every 1 to 3 weeks. One eye of each underwent trabecular laser-induced IOP elevation. Four masked operators delineated internal limiting membrane (ILM), retinal nerve fiber layer (RNFL), Bruch's membrane/retinal pigment epithelium (BM/RPE), neural canal opening (NCO), and anterior lamina cribrosa surface (ALCS) by using custom software. Longitudinal changes were assessed and compared between the EG and control (nonlasered) eyes at the onset of HRT-detected surface depression (follow-up 1; [FU1]) and at the most recent image (follow-up 2; [FU2]). Results. Mean IOP in EG eyes was 7.1 to 24.6 mm Hg at FU1 and 13.5 to 31.9 mm Hg at FU2. In control eyes, the mean IOP was 7.2 to 12.6 mm Hg (FU1) and 8.9 to 16.0 mm Hg (FU2). At FU1, neuroretinal rim decreased and ALCS depth increased significantly (paired t-test, P < 0.01); no change in RNFL thickness was detected. At FU2, however, significant prelaminar tissue thinning, posterior displacement of NCO, and RNFL thinning were observed. Conclusions. Longitudinal SDOCT imaging can detect deep ONH changes in EG eyes, the earliest of which are present at the onset of HRT-detected ONH surface height depression. These parameters represent realistic targets for SDOCT detection of glaucomatous progression in human subjects. PMID:21217108
Hood, D C; Harizman, N; Kanadani, F N; Grippo, T M; Baharestani, S; Greenstein, V C; Liebmann, J M; Ritch, R
2007-07-01
To assess the accuracy of optical coherence tomography (OCT) in detecting damage to a hemifield, patients with hemifield defects confirmed on both static automated perimetry (SAP) and multifocal visual evoked potentials (mfVEP) were studied. Eyes of 40 patients with concomitant SAP and mfVEP glaucomatous loss and 25 controls underwent OCT retinal nerve fibre layer (RNFL), mfVEP and 24-2 SAP tests. For the mfVEP and 24-2 SAP, a hemifield was defined as abnormal based upon cluster criteria. On OCT, a hemifield was considered abnormal if one of the five clock hour sectors (3 and 9 o'clock excluded) was at <1% (red) or two were at <5% (yellow). Seventy seven (43%) of the hemifields were abnormal on both mfVEP and SAP tests. The OCT was abnormal for 73 (95%) of these. Only 1 (1%) of the 100 hemifields of the controls was abnormal on OCT. Sensitivity/specificity (one eye per person) was 95/98%. The OCT RNFL test accurately detects abnormal hemifields confirmed on both subjective and objective functional tests. Identifying abnormal hemifields with a criterion of 1 red (1%) or 2 yellow (5%) clock hours may prove useful in clinical practice.
Ruggeri, Marco; Major, James C.; McKeown, Craig; Knighton, Robert W.; Puliafito, Carmen A.
2010-01-01
Purpose. To reveal three-dimensional (3-D) information about the retinal structures of birds of prey in vivo. Methods. An ultra-high resolution spectral-domain optical coherence tomography (SD-OCT) system was built for in vivo imaging of retinas of birds of prey. The calibrated imaging depth and axial resolution of the system were 3.1 mm and 2.8 μm (in tissue), respectively. 3-D segmentation was performed for calculation of the retinal nerve fiber layer (RNFL) map. Results. High-resolution OCT images were obtained of the retinas of four species of birds of prey: two diurnal hawks (Buteo platypterus and Buteo brachyurus) and two nocturnal owls (Bubo virginianus and Strix varia). These images showed the detailed retinal anatomy, including the retinal layers and the structure of the deep and shallow foveae. The calculated thickness map showed the RNFL distribution. Traumatic injury to one bird's retina was also successfully imaged. Conclusions. Ultra-high resolution SD-OCT provides unprecedented high-quality 2-D and 3-D in vivo visualization of the retinal structures of birds of prey. SD-OCT is a powerful imaging tool for vision research in birds of prey. PMID:20554605
Pocock, Ginger M.; Aranibar, Roberto G.; Kemp, Nate J.; Specht, Charles S.; Markey, Mia K.; Rylander, H.G.
2009-01-01
Purpose To determine the degree of correlation between spatial characteristics of the retinal nerve fiber layer (RNFL) birefringence (ΔnRNFL) surrounding the optic nerve head (ONH) with the corresponding anatomy of retinal ganglion cell (RGC) axons and their respective organelles. Methods RNFL phase retardation per unit depth (PR/UD, proportional to ΔnRNFL) was measured in two cynomolgus monkeys using enhanced polarization-sensitive optical coherence tomography (EPS-OCT). The monkeys were perfused with glutaraldehyde and eyes were enucleated and prepared for transmission electron microscopy (TEM) histological analysis. Morphological measurements from TEM images were used to estimate values of neurotubule density (ρRNFL), axoplasmic area (Ax) mode, axon area (Aa) mode, slope (u) of neurotubule number versus axoplasmic area [neurotubule packing density], fractional area of axoplasm in the nerve fiber bundle (f), mitochondrial fractional area in the nerve fiber bundle (xm), mitochondriated axon profile fraction (mp), and length of axonal membrane profiles per unit nerve fiber bundle area (Lam/Ab). Registered PR/UD and morphological parameters from corresponding angular sections were then correlated using Pearson’s correlation and multi-level models. Results In one eye, there was a statistically significant correlation between PR/UD and ρRNFL (r = 0.67, P =0.005) and between PR/UD and neurotubule packing density (r = 0.70, P = 0.002). Correlation coefficients of r = 0.81 (P=0.01) and r = 0.50 (P = 0.05) were observed between PR/UD and (Ax) mode for each respective subject. Conclusion Neurotubules are the primary source of birefringence in the RNFL of the primate retina. PMID:19494208
Raftopoulos, Rhian; Hickman, Simon J; Toosy, Ahmed; Sharrack, Basil; Mallik, Shahrukh; Paling, David; Altmann, Daniel R; Yiannakas, Marios C; Malladi, Prasad; Sheridan, Rose; Sarrigiannis, Ptolemaios G; Hoggard, Nigel; Koltzenburg, Martin; Gandini Wheeler-Kingshott, Claudia A M; Schmierer, Klaus; Giovannoni, Gavin; Miller, David H; Kapoor, Raju
2016-03-01
Acute demyelinating optic neuritis, a common feature of multiple sclerosis, can damage vision through neurodegeneration in the optic nerve and in its fibres in the retina. Inhibition of voltage-gated sodium channels is neuroprotective in preclinical models. In this study we aimed to establish whether sodium-channel inhibition with phenytoin is neuroprotective in patient with acute optic neuritis. We did a randomised, placebo-controlled, double-blind phase 2 trial at two UK academic hospitals in London and Sheffield. Patients with acute optic neuritis aged 18-60 years, presenting within 2 weeks of onset, with visual acuity of 6/9 or worse, were randomly assigned (1:1) by minimisation via a web-based service to oral phenytoin (maintenance dose 4 mg/kg per day if randomised before or on July 16, 2013, and 6 mg/kg per day if randomised on or after July 17, 2013) or placebo for 3 months, stratified by time from onset, centre, previous multiple sclerosis diagnosis, use of disease-modifying treatment, and use of corticosteroids for acute optic neuritis. Participants and treating and assessing physicians were masked to group assignment. The primary outcome was retinal nerve fibre layer (RNFL) thickness in the affected eye at 6 months, adjusted for fellow-eye RNFL thickness at baseline, analysed in a modified intention-to-treat population of all randomised participants who were followed up at 6 months. Safety was analysed in the entire population, including those who were lost to follow-up. The trial is registered with ClinicalTrials.gov, number NCT 01451593. We recruited 86 participants between Feb 3, 2012, and May 22, 2014 (42 assigned to phenytoin and 44 to placebo). 29 were assigned to phenytoin 4 mg/kg and 13 to phenytoin 6 mg/kg. Five participants were lost to follow-up, so the primary analysis included 81 participants (39 assigned to phenytoin and 42 to placebo). Mean 6-month RNFL thickness in the affected eye at 6 months was 81.46 μm (SD 16.27) in the phenytoin group (a mean decrease of 16.69 μm [SD 13.73] from baseline) versus 74.29 μm (15.14) in the placebo group (a mean decrease of 23.79 μm [13.97] since baseline; adjusted 6-month difference of 7.15 μm [95% CI 1.08-13.22]; p=0.021), corresponding to a 30% reduction in the extent of RNFL loss with phenytoin compared with placebo. Treatment was well tolerated, with five (12%) of 42 patients having a serious adverse event in the phenytoin group (only one, severe rash, was attributable to phenytoin) compared with two (5%) of 44 in the placebo group. These findings support the concept of neuroprotection with phenytoin in patients with acute optic neuritis at concentrations at which it blocks voltage-gated sodium channels selectively. Further investigation in larger clinical trials in optic neuritis and in relapsing multiple sclerosis is warranted. US National Multiple Sclerosis Society, Multiple Sclerosis Society of Great Britain and Northern Ireland, Novartis, UK National Institute for Health Research (NIHR), and NIHR UCLH/UCL Biomedical Research Centre. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pinto, Luciano Moreira; Costa, Elaine Fiod; Melo, Luiz Alberto S; Gross, Paula Blasco; Sato, Eduardo Toshio; Almeida, Andrea Pereira; Maia, Andre; Paranhos, Augusto
2014-04-10
We examined the structure-function relationship between two perimetric tests, the frequency doubling technology (FDT) matrix and standard automated perimetry (SAP), and two optical coherence tomography (OCT) devices (time-domain and spectral-domain). This cross-sectional study included 97 eyes from 29 healthy individuals, and 68 individuals with early, moderate, or advanced primary open-angle glaucoma. The correlations between overall and sectorial parameters of retinal nerve fiber layer thickness (RNFL) measured with Stratus and Spectralis OCT, and the visual field sensitivity obtained with FDT matrix and SAP were assessed. The relationship also was evaluated using a previously described linear model. The correlation coefficients for the threshold sensitivity measured with SAP and Stratus OCT ranged from 0.44 to 0.79, and those for Spectralis OCT ranged from 0.30 to 0.75. Regarding FDT matrix, the correlation ranged from 0.40 to 0.79 with Stratus OCT and from 0.39 to 0.79 with Spectralis OCT. Stronger correlations were found in the overall measurements and the arcuate sectors for both visual fields and OCT devices. A linear relationship was observed between FDT matrix sensitivity and the OCT devices. The previously described linear model fit the data from SAP and the OCT devices well, particularly in the inferotemporal sector. The FDT matrix and SAP visual sensitivities were related strongly to the RNFL thickness measured with the Stratus and Spectralis OCT devices, particularly in the overall and arcuate sectors. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Intravitreal erythropoietin injection in late-stage optic neuropathy: a safety study on human.
Acar, Ugur; Kucuk, Bekir; Sevinc, Mehmet Koray; Aykas, Seckin; Erdurmus, Mesut; Sobaci, Gungor
2018-06-01
To evaluate the whether intravitreal erythropoietin (EPO) administration has any beneficial or adverse effect in patients with late-stage optic neuropathy (ON) or not. The study examined 16 eyes of 16 patients who had late-stage ON and ≥1/20 best-corrected visual acuity (BCVA) in their affected eye. There were nonarteritic ischemic ON in 10 (62.5%) eyes, traumatic ON in 4 (25.0%) eyes and methanol-induced ON in 2 (12.5%) eyes. Using pars plana approach, 2000 IU/0.2 ml EPO was administered intravitreally with a 30-gauge needle. Injections were administered three times with 6-week intervals. We compared the differences in the BCVA, intraocular pressure (IOP), retinal nerve fiber layer (RNFL) thickness, pattern visual evoked potentials (p-VEP) and pattern electroretinography (p-ERG) parameters performed at initial examination and final visits. The mean age of the patients was 52.38 ± 12.00 years; 2 (12.50%) of them were female, and 14 (87.50%) of them were male. The mean BCVA levels of 16 patients with optic atrophy were 1.12 ± 0.25 logMAR at the initial examination and 1.08 ± 0.26 logMAR at the final visit (p = 0.102). There was no statistically significant difference between the initial and final RNFL thicknesses, IOP values, p-ERG or p-VEP responses. Intravitreal EPO injections have no beneficial or detrimental effect on the late stage of ON. Further studies are necessary to compare our results in patients with ON in earlier stages.
Lee, Eun Ji; Choi, Yun Jeong; Kim, Tae-Woo; Hwang, Jeong-Min
2016-01-01
To compare the deep optic nerve head (ONH) structure between normal-tension glaucoma (NTG) and nonarteritic anterior ischemic optic neuropathy (NAION) and also in healthy subjects as a control using enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). This prospective cross-sectional study included 21 NAION patients who had been diagnosed as NAION at least 6 months prior to study entry, and 42 NTG patients and 42 healthy controls who were matched with NAION patients in terms of age, intraocular pressure (IOP), and optic disc area. The retinal nerve fiber layer (RNFL) thickness in the affected sector was also matched between NAION and NTG patients. The ONH was imaged using SD-OCT with the EDI technique. The anterior lamina cribrosa surface depth (LCD) and average prelaminar tissue (PT) thickness were measured in a sector of interest in each eye and compared among the three groups. In the sector-matched comparison, LCD was largest in NTG patients, followed by NAION patients, while PT was thinner in NTG patients than in NAION patients (all P < 0.001). NAION patients had a comparable LCD and a thinner PT relative to normal controls (P = 0.170 and < 0.001, respectively). The deep ONH configuration is strikingly different between NTG and NAION. The differing features provide comparative insight into the pathophysiology of the two diseases, and may be useful for differential diagnosis.
Reflectance Speckle of Retinal Nerve Fiber Layer Reveals Axonal Activity
Huang, Xiang-Run; Knighton, Robert W.; Zhou, Ye; Zhao, Xiao-Peng
2013-01-01
Purpose. This study investigated the retinal nerve fiber layer (RNFL) reflectance speckle and tested the hypothesis that temporal change of RNFL speckle reveals axonal dynamic activity. Methods. RNFL reflectance speckle of isolated rat retinas was studied with monochromatic illumination. A series of reflectance images was collected every 5 seconds for approximately 15 minutes. Correlation coefficients (CC) of selected areas between a reference and subsequent images were calculated and plotted as a function of the time intervals between images. An exponential function fit to the time course was used to evaluate temporal change of speckle pattern. To relate temporal change of speckle to axonal activity, in vitro living retina perfused at a normal (34°C) and a lower (24°C) temperature, paraformaldehyde-fixed retina, and retina treated with microtubule depolymerization were used. Results. RNFL reflectance was not uniform; rather nerve fiber bundles had a speckled texture that changed with time. In normally perfused retina, the time constant of the CC change was 0.56 ± 0.26 minutes. In retinas treated with lower temperature and microtubule depolymerization, the time constants increased by two to four times, indicating that the speckle pattern changed more slowly. The speckled texture in fixed retina was stationary. Conclusions. Fixation stops axonal activity; treatments with either lower temperature or microtubule depolymerization are known to decrease axonal transport. The results obtained in this study suggest that temporal change of RNFL speckle reveals structural change due to axonal activity. Assessment of RNFL reflectance speckle may offer a new means of evaluating axonal function. PMID:23532525
Specific Location of Disc Hemorrhage is Linked to Nerve Fiber Layer Defects.
Yoo, Young Cheol; Kim, Joon Mo; Park, Han Seok; Yoo, Chungkwon; Shim, Seong Hee; Won, Yu Sam; Park, Ki Ho; Chang, Robert T
2017-06-01
To investigate the relationship between retinal nerve fiber layer (RNFL) defects and the quadrant and proximal location of disc hemorrhages (DHs) in a large population examined for health screening. A total of 168,044 subjects older than 20 years underwent a single screening ophthalmic examination with color fundus photography as part of a comprehensive health screening program. The presence and location of DHs and RNFL defects were assessed. The DH locations were defined according to the quadrant location (inferotemporal, superotemporal, inferonasal, or superonasal) and the most proximal end of DHs relative to the disc center (cup base, cup margin, disc rim, or extrapapillary region). Using these two location descriptors as independent variables, a logistic regression analysis was conducted to explore the effects of DH location on RNFL defects. Two hundred twenty-six eyes had DH and 120 (53.1%) of them had RNFL defects. After adjusting for proximal location, DHs located in the inferotemporal quadrant accompanied RFNL defects 12 times more frequently than those in the superonasal quadrant (odds ratio [OR], 11.81; P = .004). Conversely, after adjusting for quadrant location, the ORs for an associated RNFL defect were 3.73 (P < .001), 16.54 (P < .001), and 8.91 (P = .002) for DHs with the proximal end at the disc rim, cup margin, and cup base, respectively. Among the four quadrants and four proximal locations, DHs were identified most frequently in the inferotemporal quadrant and outside the disc, respectively. Some DH locations, such as the inferotemporal quadrant and the cup margin, were associated with RNFL defects, whereas others were not.
Development of machine learning models for diagnosis of glaucoma.
Kim, Seong Jae; Cho, Kyong Jin; Oh, Sejong
2017-01-01
The study aimed to develop machine learning models that have strong prediction power and interpretability for diagnosis of glaucoma based on retinal nerve fiber layer (RNFL) thickness and visual field (VF). We collected various candidate features from the examination of retinal nerve fiber layer (RNFL) thickness and visual field (VF). We also developed synthesized features from original features. We then selected the best features proper for classification (diagnosis) through feature evaluation. We used 100 cases of data as a test dataset and 399 cases of data as a training and validation dataset. To develop the glaucoma prediction model, we considered four machine learning algorithms: C5.0, random forest (RF), support vector machine (SVM), and k-nearest neighbor (KNN). We repeatedly composed a learning model using the training dataset and evaluated it by using the validation dataset. Finally, we got the best learning model that produces the highest validation accuracy. We analyzed quality of the models using several measures. The random forest model shows best performance and C5.0, SVM, and KNN models show similar accuracy. In the random forest model, the classification accuracy is 0.98, sensitivity is 0.983, specificity is 0.975, and AUC is 0.979. The developed prediction models show high accuracy, sensitivity, specificity, and AUC in classifying among glaucoma and healthy eyes. It will be used for predicting glaucoma against unknown examination records. Clinicians may reference the prediction results and be able to make better decisions. We may combine multiple learning models to increase prediction accuracy. The C5.0 model includes decision rules for prediction. It can be used to explain the reasons for specific predictions.
Ing, Eliesa; Ivers, Kevin M.; Yang, Hongli; Gardiner, Stuart K.; Reynaud, Juan; Cull, Grant; Wang, Lin; Burgoyne, Claude F.
2016-01-01
Purpose To use optical coherence tomography (OCT) to test the hypothesis that optic nerve head (ONH) “cupping” in the monkey optic nerve transection (ONT) model does not include posterior laminar deformation. Methods Five monkeys (aged 5.5–7.8 years) underwent ONH and retinal nerve fiber layer (RNFL) OCT imaging five times at baseline and biweekly following unilateral ONT until euthanization at ∼40% RNFL loss. Retinal nerve fiber layer thickness (RNFLT) and minimum rim width (MRW) were calculated from each pre- and post-ONT imaging session. The anterior lamina cribrosa surface (ALCS) was delineated within baseline and pre-euthanasia data sets. Significant ONT versus control eye pre-euthanasia change in prelaminar tissue thickness (PLTT), MRW, RNFLT, and ALCS depth (ALCSD) was determined using a linear mixed-effects model. Eye-specific change in each parameter exceeded the 95% confidence interval constructed from baseline measurements. Results Animals were euthanized 49 to 51 days post ONT. Overall ONT eye change from baseline was significant for MRW (−26.2%, P = 0.0011), RNFLT (−43.8%, P < 0.0001), PLTT (−23.8%, P = 0.0013), and ALCSD (−20.8%, P = 0.033). All five ONT eyes demonstrated significant eye-specific decreases in MRW (−23.7% to −31.8%) and RNFLT (−39.6% to −49.7%). Four ONT eyes showed significant PLTT thinning (−23.0% to −28.2%). The ALCS was anteriorly displaced in three of the ONT eyes (−25.7% to −39.2%). No ONT eye demonstrated posterior laminar displacement. Conclusions Seven weeks following surgical ONT in the monkey eye, ONH cupping involves prelaminar and rim tissue thinning without posterior deformation of the lamina cribrosa. PMID:27168368
Melanopsin retinal ganglion cell loss in Alzheimer disease
Ross‐Cisneros, Fred N.; Koronyo, Yosef; Hannibal, Jens; Gallassi, Roberto; Cantalupo, Gaetano; Sambati, Luisa; Pan, Billy X.; Tozer, Kevin R.; Barboni, Piero; Provini, Federica; Avanzini, Pietro; Carbonelli, Michele; Pelosi, Annalisa; Chui, Helena; Liguori, Rocco; Baruzzi, Agostino; Koronyo‐Hamaoui, Maya; Sadun, Alfredo A.; Carelli, Valerio
2015-01-01
Objective Melanopsin retinal ganglion cells (mRGCs) are photoreceptors driving circadian photoentrainment, and circadian dysfunction characterizes Alzheimer disease (AD). We investigated mRGCs in AD, hypothesizing that they contribute to circadian dysfunction. Methods We assessed retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT) in 21 mild‐moderate AD patients, and in a subgroup of 16 we evaluated rest–activity circadian rhythm by actigraphy. We studied postmortem mRGCs by immunohistochemistry in retinas, and axons in optic nerve cross‐sections of 14 neuropathologically confirmed AD patients. We coimmunostained for retinal amyloid β (Aβ) deposition and melanopsin to locate mRGCs. All AD cohorts were compared with age‐matched controls. Results We demonstrated an age‐related optic neuropathy in AD by OCT, with a significant reduction of RNFL thickness (p = 0.038), more evident in the superior quadrant (p = 0.006). Axonal loss was confirmed in postmortem AD optic nerves. Abnormal circadian function characterized only a subgroup of AD patients. Sleep efficiency was significantly reduced in AD patients (p = 0.001). We also found a significant loss of mRGCs in postmortem AD retinal specimens (p = 0.003) across all ages and abnormal mRGC dendritic morphology and size (p = 0.003). In flat‐mounted AD retinas, Aβ accumulation was remarkably evident inside and around mRGCs. Interpretation We show variable degrees of rest–activity circadian dysfunction in AD patients. We also demonstrate age‐related loss of optic nerve axons and specifically mRGC loss and pathology in postmortem AD retinal specimens, associated with Aβ deposition. These results all support the concept that mRGC degeneration is a contributor to circadian rhythm dysfunction in AD. ANN NEUROL 2016;79:90–109 PMID:26505992
Casas, Paula; Ascaso, Francisco J; Vicente, Eugenio; Tejero-Garcés, Gloria; Adiego, María I; Cristóbal, José A
2018-03-02
To assess the retinal sensitivity in obstructive sleep apnea hypopnea syndrome (OSAHS) patients evaluated with standard automated perimetry (SAP). And to correlate the functional SAP results with structural parameters obtained with optical coherence tomography (OCT). This prospective, observational, case-control study consisted of 63 eyes of 63 OSAHS patients (mean age 51.7 ± 12.7 years, best corrected visual acuity ≥20/25, refractive error less than three spherical or two cylindrical diopters, and intraocular pressure < 21 mmHg) who were enrolled and compared with 38 eyes of 38 age-matched controls. Peripapillary retinal nerve fiber layer (RNFL) thickness was measured by Stratus OCT and SAP sensitivities and indices were explored with Humphrey Field Analyzer perimeter. Correlations between functional and structural parameters were calculated, as well as the relationship between ophthalmologic and systemic indices in OSAHS patients. OSAHS patients showed a significant reduction of the sensitivity for superior visual field division (p = 0.034, t-student test). When dividing the OSAHS group in accordance with the severity of the disease, nasal peripapillary RNFL thickness was significantly lower in severe OSAHS than that in controls and mild-moderate cases (p = 0.031 and p = 0.016 respectively, Mann-Whitney U test). There were no differences between groups for SAP parameters. We found no correlation between structural and functional variables. The central visual field sensitivity of the SAP revealed a poor Pearson correlation with the apnea-hipopnea index (0.284, p = 0.024). Retinal sensitivity show minor differences between healthy subjects and OSAHS. Functional deterioration in OSAHS patients is not easy to demonstrate with visual field examination.
Qiao, Nidan; Zhang, Yichao; Ye, Zhao; Shen, Ming; Shou, Xuefei; Wang, Yongfei; Li, Shiqi; Wang, Min; Zhao, Yao
2015-10-01
There have been no studies investigating the correlation between structural [thickness of the retinal nerve fiber layer (RNFL) as determined by optical coherence tomography (OCT)] and functional [Humphrey visual field (HVF) or visual evoked potential (VEP) amplitude] measures of optic nerve integrity in patients with pituitary adenomas (PA). Patients with PAs were recruited between September 2010 and September 2013. OCT, standard automated perimetry (SAP), and multifical VEP (mfVEP) were performed. Agreement between OCT, SAP, and mfVEP values in classifying eyes/quadrants was determined using AC1 statistics. Pearson's correlation was used to examine relationships between structural and functional data. In total, 88.7% of the eyes tested showed abnormal SAP findings and 93.7% showed abnormal mfVEP findings. Only 14.8% of the eyes showed abnormal OCT findings. The agreement between SAP and mfVEP findings was 88.9% (AC1 = 0.87). The agreement between OCT and mfVEP findings was 24.2% (AC1 = -0.52), and that between OCT and SAP findings was 21.5% (AC1 = -0.56). The correlation values between RNFL thickness and the functional measurements were -0.601 for the mfVEP score (P = 0.000) and -0.441 for the SAP score (P = 0.000). The correlation between the mfVEP and SAP scores was -0.617 (P = 0.000). mfVEP, SAP, and OCT provided complementary information for detecting visual pathway abnormalities in patients with PAs. Good agreement was demonstrated between SAP and mfVEP and quantitative analysis of structure-function measurements revealed a moderate correlation.
Sun, Min; Zhang, Zhi-Qiang; Ma, Chi-Yuan; Chen, Sui-Hua; Chen, Xin-Jian
2017-01-01
To determine the dominant predictive factors of postoperative visual recovery for patients with pituitary adenoma. PubMed, Google Scholar, Web of Science and Cochrane Library were searched for relevant human studies, which investigated the prediction of the postoperative visual recovery of patients with pituitary adenoma, from January 2000 to May 2017. Meta-analyses were performed on the primary outcomes. After the related data were extracted by two independent investigators, pooled weighted mean difference (WMD) and odds ratio (OR) with 95% confidence interval (CI) were estimated using a random-effects or a fixed-effects model. Nineteen studies were included in the literature review, and nine trials were included in the Meta-analysis, which comprised 530 patients (975 eyes) with pituitary adenoma. For the primary outcomes, there was a significant difference between preoperative and postoperative mean deviation (MD) values of the visual field (WMD -5.85; 95%CI: -8.19 to -3.51; P <0.00001). Predictive characteristics of four factors were revealed in this Meta-analysis by assigning the patients to sufficient and insufficient groups according to postoperative visual field improvements, including preoperative visual field defect (WMD 10.09; 95%CI: 6.17 to 14.02; P <0.00001), patient age (WMD -12.32; 95%CI: -18.42 to -6.22; P <0.0001), symptom duration (WMD -5.04; 95%CI: -9.71 to -0.37; P =0.03), and preoperative peripapillary retinal nerve fiber layer (pRNFL) thickness (OR 0.1; 95% CI: 0.04 to 0.23; P <0.00001). Preoperative visual field defect, symptom duration, patient age, and preoperative pRNFL thickness are the dominant predictive factors of the postoperative recovery of the visual field for patients with pituitary adenoma.
Behbehani, Raed; Ahmed, Samar; Al-Hashel, Jasem; Rousseff, Rossen T; Alroughani, Raed
2017-02-01
Visual evoked potentials and spectral-domain optical coherence tomography are common ancillary studies that assess the visual pathways from a functional and structural aspect, respectively. To compare prevalence of abnormalities of Visual evoked potentials (VEP) and spectral-domain optical coherence tomography (SDOCT) in patients with relapsing remitting multiple sclerosis (RRMS). A cross-sectional study of 100 eyes with disease duration of less than 5 years since the diagnosis. Correlation between retinal nerve fiber layer and ganglion-cell/inner plexiform layer with pattern-reversal visual evoked potentials amplitude and latency and contrast sensitivity was performed. The prevalence of abnormalities in pattern-reversal visual VEP was 56% while that of SOCT was 48% in all eyes. There was significant negative correlations between the average RNFL (r=-0.34, p=0.001) and GCIPL (r=-0.39, p<0.001) with VEP latency. In eyes with prior optic neuritis, a significant negative correlation was seen between average RNFL (r=-0.33, p=0.037) and GCIPL (r=-0.40, p=0.010) with VEP latency. We have found higher prevalence of VEP abnormalities than SCOCT in early relapsing-remitting multiple sclerosis. This suggests that VEP has a higher sensitivity for detecting lesions of the visual pathway in patients with early RRMS. Copyright © 2016 Elsevier B.V. All rights reserved.
Hood, D C; Harizman, N; Kanadani, F N; Grippo, T M; Baharestani, S; Greenstein, V C; Liebmann, J M; Ritch, R
2007-01-01
Aim To assess the accuracy of optical coherence tomography (OCT) in detecting damage to a hemifield, patients with hemifield defects confirmed on both static automated perimetry (SAP) and multifocal visual evoked potentials (mfVEP) were studied. Methods Eyes of 40 patients with concomitant SAP and mfVEP glaucomatous loss and 25 controls underwent OCT retinal nerve fibre layer (RNFL), mfVEP and 24‐2 SAP tests. For the mfVEP and 24‐2 SAP, a hemifield was defined as abnormal based upon cluster criteria. On OCT, a hemifield was considered abnormal if one of the five clock hour sectors (3 and 9 o'clock excluded) was at <1% (red) or two were at <5% (yellow). Results Seventy seven (43%) of the hemifields were abnormal on both mfVEP and SAP tests. The OCT was abnormal for 73 (95%) of these. Only 1 (1%) of the 100 hemifields of the controls was abnormal on OCT. Sensitivity/specificity (one eye per person) was 95/98%. Conclusions The OCT RNFL test accurately detects abnormal hemifields confirmed on both subjective and objective functional tests. Identifying abnormal hemifields with a criterion of 1 red (1%) or 2 yellow (5%) clock hours may prove useful in clinical practice. PMID:17301118
Glaucoma and its association with obstructive sleep apnea: A narrative review
Chaitanya, Aditya; Pai, Vijaya H.; Mohapatra, Aswini Kumar; Ve, Ramesh S.
2016-01-01
Obstructive sleep apnea (OSA) is one of the systemic risk factors for glaucoma which causes irreversible visual field (VF) damage. We reviewed the published data of all types of studies on the association between these two conditions and papers regarding functional and structural changes related to glaucomatous damage using Scopus, web of science, and PubMed databases. There is evidence that the prevalence of glaucoma is higher in OSA patients, which independent of intraocular pressure (IOP). Studies have reported thinning of retinal nerve fiber layer (RNFL), alteration of optic nerve head, choroidal and macular thickness, and reduced VF sensitivity in patients of OSA with no history glaucoma. A negative correlation of apnea-hypopnea index with RNFL and VF indices has been described in some studies. Raised IOP was noted which is possibly related to obesity, supine position during sleep, and raised intracranial pressure. Diurnal fluctuations of IOP show more variations in OSA patients before and after continuous positive airway pressure (CPAP) therapy when compared with the normal cases. The vascular factors behind the pathogenesis include recurrent hypoxia with increased vascular resistance, oxidative stress damage to the optic nerve. In conclusion, comprehensive glaucoma evaluation should be recommended in patients with OSA and should also periodically monitor IOP during CPAP treatment which may trigger the progression of glaucomatous damage. PMID:27843225
Diekmann, Theresa; Schrems-Hoesl, Laura M; Mardin, Christian Y; Laemmer, Robert; Horn, Folkert K; Kruse, Friedrich E; Schrems, Wolfgang A
2018-02-01
The purpose of this study was to compare the ability of scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (SD-OCT) to predict future visual field conversion of subjects with ocular hypertension and early glaucoma. All patients were recruited from the Erlangen glaucoma registry and examined using standard automated perimetry, 24-hour intraocular pressure profile, and optic disc photography. Peripapillary retinal nerve fiber layer thickness (RNFL) measurements were obtained by SLP (GDx-VCC) and SD-OCT (Spectralis OCT). Positive and negative predictive values (PPV, NPV) were calculated for morphologic parameters of SLP and SD-OCT. Kaplan-Meier survival curves were plotted and log-rank tests were performed to compare the survival distributions. Contingency tables and Venn-diagrams were calculated to compare the predictive ability. The study included 207 patients-75 with ocular hypertension, 85 with early glaucoma, and 47 controls. Median follow-up was 4.5 years. A total of 29 patients (14.0%) developed visual field conversion during follow-up. SLP temporal-inferior RNFL [0.667; 95% confidence interval (CI), 0.281-0.935] and SD-OCT temporal-inferior RNFL (0.571; 95% CI, 0.317-0.802) achieved the highest PPV; nerve fiber indicator (0.923; 95% CI, 0.876-0.957) and SD-OCT mean (0.898; 95% CI, 0.847-0.937) achieved the highest NPV of all investigated parameters. The Kaplan-Meier curves confirmed significantly higher survival for subjects within normal limits of measurements of both devices (P<0.001). Venn diagrams tested with McNemar test statistics showed no significant difference for PPV (P=0.219) or NPV (P=0.678). Both GDx-VCC and SD-OCT demonstrate comparable results in predicting future visual field conversion if taking typical scans for GDx-VCC. In addition, the likelihood ratios suggest that GDx-VCC's nerve fiber indicator<30 may be the most useful parameter to confirm future nonconversion. (http://www.ClinicalTrials.gov number, NTC00494923; Erlangen Glaucoma Registry).
Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma
Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki
2015-01-01
Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580
Progressive Retinal Nerve Fiber Layer Atrophy Associated With Enlarging Peripapillary Pit.
Lee, Eun Ji; Kim, Tae-Woo
2017-02-01
To report a case in which progressive retinal nerve fiber layer (RNFL) atrophy was observed along with enlargement of the peripapillary pit. A 34-year-old male was diagnosed with primary open-angle glaucoma and followed up for 4 years with regular ophthalmic examinations. Both eyes were myopic (-10 D, OD and -10.5 D, OS), and untreated intraocular pressures were 18 mm Hg (OD) and 16 mm Hg (OS). A subtle depression of the superotemporal peripapillary area was deepened and emerged as a peripapillary pit during the follow-up period. With the enlargement of the peripapillary pit, a RNFL defect at the location of pit widened and thinned continuously. The enlargement of the pit was documented by the spectral-domain optical coherence tomography posterior pole scanning. Progressive RNFL atrophy was observed with enlargement of the peripapillary pit. The finding suggests that tensile stress derived from the scleral stretching may have significant influence on the integrity of the RNFL.
Repeatability of Spectral Domain Optical Coherence Tomography Measurements in High Myopia.
Rao, Harsha L; Kumar, Addepalli U; Bonala, Sampath R; Yogesh, Kadam; Lakshmi, Bodduluri
2016-05-01
The purpose of this study was to compare the repeatability of spectral domain optical coherence tomography (SDOCT) parameters in high-myopic and emmetropic healthy subjects, and to evaluate the influence of axial length on the repeatability of SDOCT parameters in high myopia. In a prospective study, 93 eyes of 63 high-myopic subjects (spherical refractive error, -6 to -12 D; median age, 25 y) and 28 eyes of 14 emmetropic (spherical refractive error, 0 D; median age, 30 y) subjects underwent optic nerve head, retinal nerve fiber layer (RNFL), and ganglion cell complex imaging with SDOCT. For the repeatability analysis, 31 eyes of 31 high-myopic subjects and 14 eyes of 14 emmetropic subjects underwent 3 repeated scans in the same session. Among the optic nerve head parameters, within-subject coefficient of variation (CVw) measurements of the disc area (0.6% vs. 0.2%), rim area (8.7 vs. 2.8), and rim volume (16.7 vs. 8.9) were significantly larger (worse) in high-myopic compared with the emmetropic subjects. CVw measurements of all RNFL (range, 1.7 to 22.4) and ganglion cell complex (range, 1.8 to 2.5) parameters in high-myopic subjects were comparable to that in emmetropic subjects (2.4 to 24.0 and 1.7 to 2.0, respectively). Axial length significantly affected the CVw of nasal (coefficient, 0.01; P=0.04) and average RNFL (coefficient, 0.004; P=0.001) parameters but not that of the other SDOCT parameters. Repeatabilities of most of the SDOCT parameters in high-myopic subjects were good and comparable to that of emmetropic subjects. This suggests that SDOCT can be useful for following up high-myopic glaucoma patients to detect progression.
Cense, B; Chen, T C; de Boer, J F
2006-01-01
Thinning of the retinal nerve fiber layer and changes in retinal nerve fiber layer birefringence may both precede clinically detectable glaucomatous vision loss. We present in vivo thickness and depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Using a fiber-based PS-OCT setup real-time images of the human retina in vivo were recorded, co-registered with retinal video images of the location of PS-OCT scans. PS-OCT scans around the optic nerve head (ONH) of two healthy young volunteers were made using 10 concentric circles of increasing radius. Both the mean retinal nerve fiber layer thickness and mean retinal nerve fiber birefringence for each of 48 sectors on a circle were determined. The retinal nerve fiber layer thickness and birefringence varied as a function of sector around the ONH. Measured double pass phase retardation per unit depth values around the ONH range between 0.10 and 0.35 degrees/microm. The retinal nerve fiber layer becomes thinner with increasing distance from the ONH. In contrast, the birefringence does not vary significantly with increasing distance from the ONH.
Suh, Min Hee; Zangwill, Linda M.; Manalastas, Patricia Isabel C.; Belghith, Akram; Yarmohammadi, Adeleh; Medeiros, Felipe A.; Diniz-Filho, Alberto; Saunders, Luke J.; Weinreb, Robert N.
2016-01-01
Purpose To investigate factors associated with dropout of the deep retinal layer microvasculature within the β-zone parapapillary atrophy (βPPA) assessed by optical coherence tomography angiography (OCT-A) in glaucomatous eyes. Design Cross-sectional study. Participants Seventy-one eyes from 71 primary open angle glaucoma (POAG) patients with βPPA enrolled in the Diagnostic Innovations in Glaucoma Study. Methods βPPA deep layer microvasculature dropout was defined as a complete loss of the microvasculature located within deep retinal layer of the βPPA from OCT-A-derived optic nerve head vessel density maps by standardized qualitative assessment. Circumpapillary vessel density (cpVD) within the retinal nerve fiber layer (RNFL) was also calculated using OCT-A. Choroidal thickness and presence of the focal lamina cribrosa (LC) defect were determined using swept-source OCT. Main Outcome Measures Presence of the βPPA deep layer microvasculature dropout. Parameters including age, systolic and diastolic blood pressure, axial length, intraocular pressure, disc hemorrhage, cpVD, visual field (VF) mean deviation (MD), focal LC defect, βPPA area, and choroidal thickness were analyzed. Results βPPA deep layer microvasculature dropout was detected in 37 eyes (52.1%) of eyes with POAG. Eyes with dropouts had a higher prevalence of LC defect (70.3 vs. 32.4%), lower cpVD (52.7 vs. 58.8%), worse VF MD (-9.06 vs. -3.83dB), thinner total choroidal thickness (126.5 vs. 169.1/μm), longer axial length (24.7 vs. 24.0mm), larger βPPA (1.2 vs. 0.76mm2) and lower diastolic blood pressure (74.7 vs. 81.7mmHg) than those without dropouts (P< 0.05, respectively). In the multivariate logistic regression, higher prevalence of focal LC defect (odds ratio [OR], 6.27; P = 0.012), reduced cpVD (OR, 1.27; P = 0.002), worse VF MD (OR, 1.27; P = 0.001), thinner choroidal thickness (OR, 1.02; P = 0.014), and lower diastolic blood pressure (OR, 1.16; P = 0.003) were significantly associated with the dropout. Conclusions Certain systemic and ocular factors such as focal LC defect, more advanced disease status, reduced RNFL vessel density, thinner choroidal thickness, and lower diastolic blood pressure were factors associated with the βPPA deep layer microvasculature dropout in glaucomatous eyes. Longitudinal studies are required to elucidate the temporal relationship between βPPA deep layer dropout and these factors. PMID:27769587
Suh, Min Hee; Zangwill, Linda M; Manalastas, Patricia Isabel C; Belghith, Akram; Yarmohammadi, Adeleh; Medeiros, Felipe A; Diniz-Filho, Alberto; Saunders, Luke J; Weinreb, Robert N
2016-12-01
To investigate factors associated with dropout of the parapapillary deep retinal layer microvasculature assessed by optical coherence tomography angiography (OCTA) in glaucomatous eyes. Cross-sectional study. Seventy-one eyes from 71 primary open-angle glaucoma (POAG) patients with β-zone parapapillary atrophy (βPPA) enrolled in the Diagnostic Innovations in Glaucoma Study. Parapapillary deep-layer microvasculature dropout was defined as a complete loss of the microvasculature located within the deep retinal layer of the βPPA from OCTA-derived optic nerve head vessel density maps by standardized qualitative assessment. Circumpapillary vessel density (cpVD) within the retinal nerve fiber layer (RNFL) also was calculated using OCTA. Choroidal thickness and presence of focal lamina cribrosa (LC) defects were determined using swept-source optical coherence tomography. Presence of parapapillary deep-layer microvasculature dropout. Parameters including age, systolic and diastolic blood pressure, axial length, intraocular pressure, disc hemorrhage, cpVD, visual field (VF) mean deviation (MD), focal LC defects βPPA area, and choroidal thickness were analyzed. Parapapillary deep-layer microvasculature dropout was detected in 37 POAG eyes (52.1%). Eyes with microvasculature dropout had a higher prevalence of LC defects (70.3% vs. 32.4%), lower cpVD (52.7% vs. 58.8%), worse VF MD (-9.06 dB vs. -3.83 dB), thinner total choroidal thickness (126.5 μm vs. 169.1 μm), longer axial length (24.7 mm vs. 24.0 mm), larger βPPA (1.2 mm 2 vs. 0.76 mm 2 ), and lower diastolic blood pressure (74.7 mmHg vs. 81.7 mmHg) than those without dropout (P < 0.05, respectively). In the multivariate logistic regression analysis, higher prevalence of focal LC defects (odds ratio [OR], 6.27; P = 0.012), reduced cpVD (OR, 1.27; P = 0.002), worse VF MD (OR, 1.27; P = 0.001), thinner choroidal thickness (OR, 1.02; P = 0.014), and lower diastolic blood pressure (OR, 1.16; P = 0.003) were associated significantly with the dropout. Systemic and ocular factors including focal LC defects more advanced glaucoma, reduced RNFL vessel density, thinner choroidal thickness, and lower diastolic blood pressure were factors associated with the parapapillary deep-layer microvasculature dropout in glaucomatous eyes. Longitudinal studies are required to elucidate the temporal relationship between parapapillary deep-layer microvasculature dropout and systemic and ocular factors. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Optical Coherence Tomography in Glaucoma
NASA Astrophysics Data System (ADS)
Berisha, Fatmire; Hoffmann, Esther M.; Pfeiffer, Norbert
Retinal nerve fiber layer (RNFL) thinning and optic nerve head cupping are key diagnostic features of glaucomatous optic neuropathy. The higher resolution of the recently introduced SD-OCT offers enhanced visualization and improved segmentation of the retinal layers, providing a higher accuracy in identification of subtle changes of the optic disc and RNFL thinning associated with glaucoma.
High-speed polarization sensitive optical coherence tomography for retinal diagnostics
NASA Astrophysics Data System (ADS)
Yin, Biwei; Wang, Bingqing; Vemishetty, Kalyanramu; Nagle, Jim; Liu, Shuang; Wang, Tianyi; Rylander, Henry G., III; Milner, Thomas E.
2012-01-01
We report design and construction of an FPGA-based high-speed swept-source polarization-sensitive optical coherence tomography (SS-PS-OCT) system for clinical retinal imaging. Clinical application of the SS-PS-OCT system is accurate measurement and display of thickness, phase retardation and birefringence maps of the retinal nerve fiber layer (RNFL) in human subjects for early detection of glaucoma. The FPGA-based SS-PS-OCT system provides three incident polarization states on the eye and uses a bulk-optic polarization sensitive balanced detection module to record two orthogonal interference fringe signals. Interference fringe signals and relative phase retardation between two orthogonal polarization states are used to obtain Stokes vectors of light returning from each RNFL depth. We implement a Levenberg-Marquardt algorithm on a Field Programmable Gate Array (FPGA) to compute accurate phase retardation and birefringence maps. For each retinal scan, a three-state Levenberg-Marquardt nonlinear algorithm is applied to 360 clusters each consisting of 100 A-scans to determine accurate maps of phase retardation and birefringence in less than 1 second after patient measurement allowing real-time clinical imaging-a speedup of more than 300 times over previous implementations. We report application of the FPGA-based SS-PS-OCT system for real-time clinical imaging of patients enrolled in a clinical study at the Eye Institute of Austin and Duke Eye Center.
Oddone, Francesco; Lucenteforte, Ersilia; Michelessi, Manuele; Rizzo, Stanislao; Donati, Simone; Parravano, Mariacristina; Virgili, Gianni
2016-05-01
Macular parameters have been proposed as an alternative to retinal nerve fiber layer (RNFL) parameters to diagnose glaucoma. Comparing the diagnostic accuracy of macular parameters, specifically the ganglion cell complex (GCC) and ganglion cell inner plexiform layer (GCIPL), with the accuracy of RNFL parameters for detecting manifest glaucoma is important to guide clinical practice and future research. Studies using spectral domain optical coherence tomography (SD OCT) and reporting macular parameters were included if they allowed the extraction of accuracy data for diagnosing manifest glaucoma, as confirmed with automated perimetry or a clinician's optic nerve head (ONH) assessment. Cross-sectional cohort studies and case-control studies were included. The QUADAS 2 tool was used to assess methodological quality. Only direct comparisons of macular versus RNFL parameters (i.e., in the same study) were conducted. Summary sensitivity and specificity of each macular or RNFL parameter were reported, and the relative diagnostic odds ratio (DOR) was calculated in hierarchical summary receiver operating characteristic (HSROC) models to compare them. Thirty-four studies investigated macular parameters using RTVue OCT (Optovue Inc., Fremont, CA) (19 studies, 3094 subjects), Cirrus OCT (Carl Zeiss Meditec Inc., Dublin, CA) (14 studies, 2164 subjects), or 3D Topcon OCT (Topcon, Inc., Tokyo, Japan) (4 studies, 522 subjects). Thirty-two of these studies allowed comparisons between macular and RNFL parameters. Studies generally reported sensitivities at fixed specificities, more commonly 0.90 or 0.95, with sensitivities of most best-performing parameters between 0.65 and 0.75. For all OCT devices, compared with RNFL parameters, macular parameters were similarly or slightly less accurate for detecting glaucoma at the highest reported specificity, which was confirmed in analyses at the lowest specificity. Included studies suffered from limitations, especially the case-control study design, which is known to overestimate accuracy. However, this flaw is less relevant as a source of bias in direct comparisons conducted within studies. With the use of OCT, RNFL parameters are still preferable to macular parameters for diagnosing manifest glaucoma, but the differences are small. Because of high heterogeneity, direct comparative or randomized studies of OCT devices or OCT parameters and diagnostic strategies are essential. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Retinal layer segmentation in multiple sclerosis: a systematic review and meta-analysis.
Petzold, Axel; Balcer, Laura J; Calabresi, Peter A; Costello, Fiona; Frohman, Teresa C; Frohman, Elliot M; Martinez-Lapiscina, Elena H; Green, Ari J; Kardon, Randy; Outteryck, Olivier; Paul, Friedemann; Schippling, Sven; Vermersch, Patrik; Villoslada, Pablo; Balk, Lisanne J
2017-10-01
Structural retinal imaging biomarkers are important for early recognition and monitoring of inflammation and neurodegeneration in multiple sclerosis. With the introduction of spectral domain optical coherence tomography (SD-OCT), supervised automated segmentation of individual retinal layers is possible. We aimed to investigate which retinal layers show atrophy associated with neurodegeneration in multiple sclerosis when measured with SD-OCT. In this systematic review and meta-analysis, we searched for studies in which SD-OCT was used to look at the retina in people with multiple sclerosis with or without optic neuritis in PubMed, Web of Science, and Google Scholar between Nov 22, 1991, and April 19, 2016. Data were taken from cross-sectional cohorts and from one timepoint from longitudinal studies (at least 3 months after onset in studies of optic neuritis). We classified data on eyes into healthy controls, multiple-sclerosis-associated optic neuritis (MSON), and multiple sclerosis without optic neuritis (MSNON). We assessed thickness of the retinal layers and we rated individual layer segmentation performance by random effects meta-analysis for MSON eyes versus control eyes, MSNON eyes versus control eyes, and MSNON eyes versus MSON eyes. We excluded relevant sources of bias by funnel plots. Of 25 497 records identified, 110 articles were eligible and 40 reported data (in total 5776 eyes from patients with multiple sclerosis [1667 MSON eyes and 4109 MSNON eyes] and 1697 eyes from healthy controls) that met published OCT quality control criteria and were suitable for meta-analysis. Compared with control eyes, the peripapillary retinal nerve fibre layer (RNFL) showed thinning in MSON eyes (mean difference -20·10 μm, 95% CI -22·76 to -17·44; p<0·0001) and in MSNON eyes (-7·41 μm, -8·98 to -5·83; p<0·0001). The macula showed RNFL thinning of -6·18 μm (-8·07 to -4·28; p<0·0001) in MSON eyes and -2·15 μm (-3·15 to -1·15; p<0·0001) in MSNON eyes compared with control eyes. Atrophy of the macular ganglion cell layer and inner plexiform layer (GCIPL) was -16·42 μm (-19·23 to -13·60; p<0·0001) for MSON eyes and -6·31 μm (-7·75 to -4·87; p<0·0001) for MSNON eyes compared with control eyes. A small degree of inner nuclear layer (INL) thickening occurred in MSON eyes compared with control eyes (0·77 μm, 0·25 to 1·28; p=0·003). We found no statistical difference in the thickness of the combined outer nuclear layer and outer plexiform layer when we compared MSNON or MSON eyes with control eyes, but we found a small degree of thickening of the combined layer when we compared MSON eyes with MSNON eyes (1·21 μm, 0·24 to 2·19; p=0·01). The largest and most robust differences between the eyes of people with multiple sclerosis and control eyes were found in the peripapillary RNFL and macular GCIPL. Inflammatory disease activity might be captured by the INL. Because of the consistency, robustness, and large effect size, we recommend inclusion of the peripapillary RNFL and macular GCIPL for diagnosis, monitoring, and research. None. Copyright © 2017 Elsevier Ltd. All rights reserved.
Alluwimi, Muhammed S.; Swanson, William H.; Malinovsky, Victor E.; King, Brett J.
2018-01-01
Purpose Prior studies suggested the use of customized perimetric locations in glaucoma; these studies were limited by imaging only the superficial depths of the retinal nerve fiber layer (RNFL) and by prolonged perimetric testing. We aimed to develop a rapid perimetric test guided by high-resolution images of RNFL bundles. Methods We recruited 10 patients with glaucoma, ages 56 to 80 years, median 68 years, and 10 controls, ages 55 to 77 years, median 68 years. The patients were selected based on discrepancies between locations of glaucomatous damage for perimetric and structural measures. Montaging was used to produce optical coherence tomography en face images of the RNFL covering much of the 24-2 grid locations. In experiment 1, we presented the Goldmann size III stimulus at preselected retinal locations of glaucomatous damage, using just two contrasts. In experiment 2, we developed an elongated sinusoidal stimulus, aligned within the defect, to measure contrast sensitivities; abnormalities were defined based on lower 95% reference limits derived from the controls. Results The percentage of predicted locations where size III was not seen at 28 dB ranged from 16% to 80%, with a median of 48%. Contrast sensitivity for the sinusoidal stimulus was below the 95% reference range for 37 of 44 stimuli aligned within the defects. Conclusions We developed methods for rapid perimetric testing guided by en face images of the RNFL bundles in patients with glaucoma. Results indicated ganglion cell damage under all of the visible RNFL defects. Translational Relevance Customized perimetric locations have potential to improve clinical assessment of glaucoma. PMID:29576929
Wang, Xiaolei; Kong, Xiangmei; Jiang, Chunhui; Li, Mengwei; Yu, Jian; Sun, Xinghuai
2016-03-11
The aim of this study was to evaluate the peripapillary and parafoveal perfusion of young, healthy myopic subjects with spectral domain optical coherence tomography (OCT) angiography. A prospective comparative study was conducted from December 2014 to January 2015. Participants recruited from a population-based study performed by the Eye, Ear, Nose and Throat Hospital of Fudan University in Shanghai. A total of 78 Chinese normal subjects (78 eyes) with different refraction were included. Myopia was divided into 4 groups on the basis of the refractive status: 20 eyes with emmetropia (mean spherical equivalent (MSE) 0.50D to -0.50D), 20 eyes with mild myopia (MSE -0.75D to -2.75D), 20 eyes with moderate myopia (MSE -3.00D to -5.75D), and 18 eyes with high myopia (MSE≤-6.00D). Peripapillary and parafoveal retinal and choroidal perfusion parameters and their relationships with axial length (AL) and retinal nerve fibre layer (RNFL) thickness were analysed. Significant differences were found for the retinal flow index and vessel density in the peripapillary area among the 4 groups, but not in the parafoveal area. The high myopia group had the lowest peripapillary retinal flow index and vessel density. In addition, there was a negative correlation (β=-0.002, p=0.047) between the AL and peripapillary retinal flow index and a positive correlation between RNFL thickness and the peripapillary retinal perfusion parameters (flow index: β=0.001, p=0.006; vessel density: β=0.350, p=0.002) even after adjustment for other variables. Highly myopic eyes have a decreased peripapillary retinal perfusion compared with emmetropic eyes. Such vascular features might increase the susceptibility to vascular-related eye diseases. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Mendez-Hernandez, Carmen; Rodriguez-Uña, Ignacio; Gonzalez-de-la Rosa, Manuel; Arribas-Pardo, Paula; Garcia-Feijoo, Julian
2016-11-01
The computer program laguna onhe determines optic nerve head haemoglobin (ONH Hb) on retinal photographs based on detecting colour differences. This study compares the diagnostic capacity of Laguna ONhE with that of spectral domain optical coherence tomography (OCT) and confocal tomography (HRT III). In a prospective, observational, cross-sectional study, glaucomatous (n = 66) and healthy (n = 52) eyes were examined by Spectralis OCT, HRT III and Laguna ONhE. The following Laguna ONhE variables were determined: ONH Hb across the vertical disc diameter (8&20 Hb), estimated cup-disc ratio (C/D) and the glaucoma discriminant function (GDF), which combines the slope of Hb amount with the mean in 8&20 Hb. The three diagnostic methods were compared by calculating areas under ROC curves (AUCs). Correlations between variables were assessed through Spearman's rho coefficient. Areas under ROC curves (AUCs) were 0.785 (95% CI: 0.700-0.863) for GDF, 0.807 (95% CI: 0.730-0.883) for OCT retinal nerve fibre layer thickness (OCT-RNFL) and 0.714 (95% CI: 0.618-0.810) and 0.721 (95% CI: 0.628-0.815) for the HRT III variable GPS (glaucoma probability score) and vertical C/D ratio, respectively. Glaucoma discriminant function (GDF) was correlated with OCT-RNFL (0.587, p 0.001; 0.507, p 0.045; and -0.119, p 0.713 for mild, moderate and advanced glaucoma, respectively), mostly so with inferior OCT-RNFL (0.622; p < 0.001). Glaucoma discriminant function (GDF)-HRT III correlations were lower (rim area 0.471, p < 0.0001; rim/disc area 0.426, p < 0.0001; vertical C/D -0.413, p < 0.0001; GPS -0.408, p < 0.0001; rim volume 0.341, p < 0.0001). Similar diagnostic power was observed for Laguna ONhE, Spectralis OCT and HRT III. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Laron, Michal; Cheng, Han; Zhang, Bin; Schiffman, Jade S.; Tang, Rosa A.; Frishman, Laura J.
2010-01-01
Background Multifocal visual evoked potentials (mfVEP) measure local response amplitude and latency in the field of vision Objective To compare the sensitivity of mfVEP, Humphrey visual field (HVF) and optical coherence tomography (OCT) in detecting visual abnormality in multiple sclerosis (MS) patients. Methods MfVEP, HVF, and OCT (retinal nerve fiber layer [RNFL]) were performed in 47 MS-ON eyes (last optic neuritis (ON) attack ≥ 6 months prior) and 65 MS-no-ON eyes without ON history. Criteria to define an eye as abnormal were: mfVEP 1) amplitude/latency: either amplitude or latency probability plots meeting cluster criteria with 95% specificity 2) amplitude or latency alone (specificity: 97% and 98%, respectively); HVF and OCT, mean deviation and RNFL thickness meeting p < 0.05, respectively. Results MfVEP (amplitude/latency) identified more abnormality in MS-ON eyes (89%) than HVF (72%), OCT (62%), mfVEP amplitude (66%) or latency (67%) alone. 18% of MS-no-ON eyes were abnormal for both mfVEP (amplitude/latency) and HVF compared to 8% with OCT. Agreement between tests ranged from 60% to 79%. MfVEP (amplitude/latency) categorized an additional 15% of MS-ON eyes as abnormal compared to HVF and OCT combined. Conclusions MfVEP, which detects both demyelination (increased latency) and neural degeneration (reduced amplitude) revealed more abnormality than HVF or OCT in MS patients. PMID:20207786
Retinal nerve fiber layer reflectance for early glaucoma diagnosis.
Liu, Shuang; Wang, Bingqing; Yin, Biwei; Milner, Thomas E; Markey, Mia K; McKinnon, Stuart J; Rylander, Henry G
2014-01-01
Compare performance of normalized reflectance index (NRI) and retinal nerve fiber layer thickness (RNFLT) parameters determined from optical coherence tomography (OCT) images for glaucoma and glaucoma suspect diagnosis. Seventy-five eyes from 71 human subjects were studied: 33 controls, 24 glaucomatous, and 18 glaucoma-suspects. RNFLT and NRI maps were measured using 2 custom-built OCT systems and the commercial instrument RTVue. Using area under the receiver operating characteristic curve, RNFLT and NRI measured in 7 RNFL locations were analyzed to distinguish between control, glaucomatous, and glaucoma-suspect eyes. The mean NRI of the control group was significantly larger than the means of glaucomatous and glaucoma-suspect groups in most RNFL locations for all 3 OCT systems (P<0.05 for all comparisons). NRI performs significantly better than RNFLT at distinguishing between glaucoma-suspect and control eyes using RTVue OCT (P=0.008). The performances of NRI and RNFLT for classifying glaucoma-suspect versus control eyes were statistically indistinguishable for PS-OCT-EIA (P=0.101) and PS-OCT-DEC (P=0.227). The performances of NRI and RNFLT for classifying glaucomatous versus control eyes were statistically indistinguishable (PS-OCT-EIA: P=0.379; PS-OCT-DEC: P=0.338; RTVue OCT: P=0.877). NRI is a promising measure for distinguishing between glaucoma-suspect and control eyes and may indicate disease in the preperimetric stage. Results of this pilot clinical study warrant a larger study to confirm the diagnostic power of NRI for diagnosing preperimetric glaucoma.
Comparison of Ocular Outcomes in Two 14-Day Bed Rest Studies
NASA Technical Reports Server (NTRS)
Cromwell, R. L.; Zanello, S. B.; Yarbough, P. O.; Taibbi, G.; Vizzeri, G.
2011-01-01
Reports of astronauts visual changes raised concern about ocular health during long-duration spaceflight. Some of these findings included hyperopic shifts, choroidal folds, optic disc edema, retinal nerve fiber layer (RNFL) thickening, and cotton wool spots. While the etiology remains unknown, hypotheses speculate that hypertension in the brain caused by cephalad fluid shifts during spaceflight is a possible mechanism for these ocular changes. Head-down tilt (HDT) bed rest is a spaceflight analog that induces cephalad fluid shifts. In addition, previous studies of the HDT position demonstrated body fluid shifts associated with changes in intraocular pressure (IOP). For these reasons, vision monitoring of HDT bed rest subjects was implemented for NASA bed rest studies. Subjects selected for these studies were healthy adults (14 males and 5 females). Average age was 37.5 plus or minus 9.1 years, weight was 77.4 plus or minus 11.3 Kg, and height was 173.4 plus or minus 7.2 14 cm. Controlled conditions followed for all NASA bed rest studies were implemented. These conditions included factors such as eating a standardized diet, maintaining a strict sleep wake cycle, and remaining in bed for 24 hours each day. In one study, subjects maintained a horizontal (0 degree) position while in bed and were exercised six days per week with an integrated resistance and aerobic training (iRAT) program. In the other study, subjects were placed at 6 degrees HDT while in bed and did not engage in exercise. All subjects underwent pre- and post bed rest vision testing. While the battery of vision tests for each study was not identical, measures common to both studies will be presented. These measures included IOP and measures that provided an indication of optic disc swelling as derived from optical coherence tomography (OCT) testing: average retinal nerve fiber layer (RNFL) thickness (millimeters), disc area (square millimeters), rim area (square millimters), and average cup to disc (C/D) ratio. For all measures, there was no significant difference between subject groups for pre-bed rest testing. Post bed rest values also remained similar between groups. Comparison of pre- to post bed rest testing within each group did not demonstrate any statistical differences. These preliminary results from 14-day bed rest studies suggest that the combination of exercise and horizontal bed rest as compared to 6 degrees HDT bed rest did not produce differences in the ocular response with regard to IOP and optic disc parameters. The ocular measures reported here only included pre- and post bed rest time points. Further investigation is needed to examine both the acute response and long term adaptation of structural and functional ocular parameters in the bed rest platform and determine its usefulness for studying spaceflight phenomena. From a clinical perspective, the ability to study ocular responses in the controlled environment of the bed rest platform can provide valuable information for the care of patients restricted to bed rest.
Registration of adaptive optics corrected retinal nerve fiber layer (RNFL) images
Ramaswamy, Gomathy; Lombardo, Marco; Devaney, Nicholas
2014-01-01
Glaucoma is the leading cause of preventable blindness in the western world. Investigation of high-resolution retinal nerve fiber layer (RNFL) images in patients may lead to new indicators of its onset. Adaptive optics (AO) can provide diffraction-limited images of the retina, providing new opportunities for earlier detection of neuroretinal pathologies. However, precise processing is required to correct for three effects in sequences of AO-assisted, flood-illumination images: uneven illumination, residual image motion and image rotation. This processing can be challenging for images of the RNFL due to their low contrast and lack of clearly noticeable features. Here we develop specific processing techniques and show that their application leads to improved image quality on the nerve fiber bundles. This in turn improves the reliability of measures of fiber texture such as the correlation of Gray-Level Co-occurrence Matrix (GLCM). PMID:24940551
Registration of adaptive optics corrected retinal nerve fiber layer (RNFL) images.
Ramaswamy, Gomathy; Lombardo, Marco; Devaney, Nicholas
2014-06-01
Glaucoma is the leading cause of preventable blindness in the western world. Investigation of high-resolution retinal nerve fiber layer (RNFL) images in patients may lead to new indicators of its onset. Adaptive optics (AO) can provide diffraction-limited images of the retina, providing new opportunities for earlier detection of neuroretinal pathologies. However, precise processing is required to correct for three effects in sequences of AO-assisted, flood-illumination images: uneven illumination, residual image motion and image rotation. This processing can be challenging for images of the RNFL due to their low contrast and lack of clearly noticeable features. Here we develop specific processing techniques and show that their application leads to improved image quality on the nerve fiber bundles. This in turn improves the reliability of measures of fiber texture such as the correlation of Gray-Level Co-occurrence Matrix (GLCM).
Faria, Mun Y; Ferreira, Nuno P; Mano, Sofia; Cristóvao, Diana M; Sousa, David C; Monteiro-Grillo, Manuel E
2018-05-01
To provide a spectral-domain optical coherence tomography (SD-OCT)-based analysis of retinal layers thickness and nasal displacement of closed macular hole after internal limiting membrane peeling in macular hole surgery. In this nonrandomized prospective interventional study, 36 eyes of 32 patients were subjected to pars plana vitrectomy and 3.5 mm diameter internal limiting membrane (ILM) peeling for idiopathic macular hole (IMH). Nasal and temporal internal retinal layer thickness were assessed with SD-OCT. Each scan included optic disc border so that distance between optic disc border and fovea were measured. Thirty-six eyes had a successful surgery with macular hole closure. Total nasal retinal thickening (p<0.001) and total temporal retinal thinning (p<0.0001) were observed. Outer retinal layers increased thickness after surgery (nasal p<0.05 and temporal p<0.01). Middle part of inner retinal layers (mIRL) had nasal thickening (p<0.001) and temporal thinning (p<0.05). The mIRL was obtained by deducting ganglion cell layer (GCL) and retinal nerve fiber layer (RNFL) thickness from overall thickness of the inner retinal layer. Papillofoveal distance was shorter after ILM peeling in macular hole surgery (3,651 ± 323 μm preoperatively and 3,361 ± 279 μm at 6 months; p<0.0001). Internal limiting membrane peel is associated with important alteration in inner retinal layer architecture, with thickening of mIRL and shortening of papillofoveal distance. These factors may contribute to recovery of disrupted foveal photoreceptor and vision improvement after IMH closure.
A Comparison of Functional and Structural Measures for Identifying Progression of Glaucoma
Xin, Daiyan; Greenstein, Vivienne C.; Ritch, Robert; Liebmann, Jeffrey M.; De Moraes, Carlos Gustavo
2011-01-01
Purpose. To compare glaucoma progression by functional and structural tests. Methods. The authors prospectively studied 33 glaucoma patients (55 eyes); 20 eyes (15 patients) had disc hemorrhage, and 35 eyes (18 patients) had exfoliation glaucoma. The following tests were performed at two baseline and three follow-up examinations: frequency doubling perimetry (FDT), 24-2 Humphrey visual fields (HVF), multifocal visual evoked potentials (mfVEP), and optical coherence tomography (OCT). To identify progression, the baseline measurements were averaged and compared to those obtained at the final examination. Stereophotographs of the optic disc were obtained at baseline and compared with those at the final examination. Results. Patients were followed up for 21.1 ± 1.8 months. For HVF there were significant changes in mean deviation (MD) in eight (14.5%) eyes but in pattern standard deviation (P/SD) in only two (3.6%) eyes. For FDT, there were significant changes in MD in 13 (23.6%) eyes. Five eyes showed changes in MD for HVF and FDT. For mfVEP, there was an increase in abnormal points in nine (16.4%) eyes. Six of these eyes did not show significant HVF or FDT changes. For OCT, RNFL average thickness values were significantly decreased in nine (16.4%) eyes. Nine (16.4%) eyes showed progression on stereophotography; four of these eyes did not show significant changes on OCT and functional tests. Conclusions. Each test showed evidence of progression in some eyes. However, agreement among tests and stereophotography regarding which eyes showed progression was poor, illustrating the importance of following up patients with a combination of functional and structural tests. PMID:20847115
Rao, Harsha L; Kumbar, Tukaram; Addepalli, Uday K; Bharti, Neha; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2012-02-29
To evaluate the influence of a control group on the diagnostic accuracy of spectral-domain optical coherence tomography (SD-OCT) in early glaucoma. In a diagnostic, case-control study, 119 eyes of 60 normal subjects with no findings suspicious for glaucoma (control cohort 1); 76 eyes of 41 subjects referred by general ophthalmologists as glaucoma suspects based on optic disc morphology, but found by glaucoma experts to be normal but with physiological variations in their optic nerves (control cohort 2); and 65 eyes of 46 early-glaucoma patients (cases) underwent imaging of the optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) by SD-OCT. Areas under the receiver operating characteristic curves (AUC) of ONH parameters discriminating glaucomatous eyes from normal eyes of control cohort 2 were significantly lesser (P < 0.001) than those discriminating glaucomatous eyes from normal eyes of control cohort 1. AUCs of RNFL parameters discriminating glaucomatous eyes from normal eyes of control cohorts 2 and 1 were comparable. Although the AUCs of GCC thickness parameters were comparable, AUCs of GCC focal and global loss volume in control cohort 2 (0.684 and 0.671. respectively) were significantly less (P < 0.05) than in control cohort 1 (0.881 and 0.841, respectively). The effectiveness of most SD-OCT parameters in detecting glaucoma significantly decreased when evaluated against a clinically relevant control group with suspicious-looking optic nerves compared with that against a control group consisting of normal subjects with no findings suspicious for glaucoma.
High-Resolution Imaging of the Optic Nerve and Retina in Optic Nerve Hypoplasia
Pilat, Anastasia; Sibley, Daniel; McLean, Rebecca J.; Proudlock, Frank A.; Gottlob, Irene
2015-01-01
Purpose To investigate the optic nerve and macular morphology in patients with optic nerve hypoplasia (ONH) using spectral-domain optical coherence tomography (SD OCT). Design Prospective, cross-sectional, observational study. Subjects A total of 16 participants with ONH (10 female and 6 male; mean age, 17.2 years; 6 bilateral involvement) and 32 gender-, age-, ethnicity-, and refraction-matched healthy controls. Methods High-resolution SD OCT (Copernicus [Optopol Technology S.A., Zawiercie, Poland], 3 μm resolution) and handheld SD OCT (Bioptigen Inc [Research Triangle Park, NC], 2.6 μm resolution) devices were used to acquire horizontal scans through the center of the optic disc and macula. Main Outcome Measures Horizontal optic disc/cup and rim diameters, cup depth, peripapillary retinal nerve fiber layer (RNFL), and thickness of individual retinal layers in participants with ONH and in controls. Results Patients with ONH had significantly smaller discs (P < 0.03 and P < 0.001 compared with unaffected eye and healthy controls, respectively), horizontal cup diameter (P < 0.02 for both), and cup depth (P < 0.02 and P < 0.01, respectively). In the macula, significantly thinner RNFL (nasally), ganglion cell layer (GCL) (nasally and temporally), inner plexiform layer (IPL) (nasally), outer nuclear layer (ONL) (nasally), and inner segment (centrally and temporally) were found in patients with ONH compared with the control group (P < 0.05 for all comparisons). Continuation of significantly thicker GCL, IPL, and outer plexiform layer in the central retinal area (i.e., foveal hypoplasia) was found in more than 80% of patients with ONH. Clinically unaffected fellow eyes of patients with ONH showed mild features of underdevelopment. Visual acuity and presence of septo-optic dysplasia were associated with changes in GCL and IPL. Sensitivity and specificity for the detection of ONH based on disc and retinal optical coherence tomography (OCT) parameters were >80%. Conclusions Our study provides evidence of retinal changes in ONH. In addition to thinning of retina layers mainly involving the RNFL and GCL, signs reminiscent of foveal hypoplasia were observed in patients with ONH. Optic nerve and foveal parameters measured using OCT showed high sensitivity and specificity for detecting ONH, demonstrating their useful for clinical diagnosis. PMID:25939636
Ocular Outcomes Comparison Between 14- and 70-day Head-down Tilt Bed Rest
NASA Technical Reports Server (NTRS)
Cromwell, R.L.; Taibbi, G.; Zanello, S.B.; Yarbough, P.O.; Ploutz-Snyder, R.J.; Vizzen, G.
2015-01-01
INTRODUCTION: Ophthalmological changes, including optic disc edema with optic nerve sheath distension, posterior globe flattening with hyperopic shift, choroidal folds and cotton wool spots have been detected in some astronauts involved in long-duration spaceflights. (sup 1) It is hypothesized that elevated intracranial pressure resulting from microgravity-induced cephalad fluid shifts may be responsible for most of these findings. Head-down tilt bed rest (HTDBR) is a ground-based microgravity analog which also produces cephalad fluid shifts. It is conceivable that prolonged HDTBR exposure may induce ocular changes similar to those experienced in microgravity. Therefore, the purpose of the present study was to compare structural and functional ocular outcomes between 14- and 70-day HDTBR in healthy human subjects. It is hypothesized that 70-d HDTBR induced ocular changes of greater magnitude as compared to 14-d HDTBR. METHODS: Two HDTBR studies were conducted at the NASA Flight Analogs Research Unit, located at The University of Texas Medical Branch at Galveston, TX. Identical NASA standard screening procedures and BR conditions (e.g., strict sleep-wake cycle, standardized diet, continuous video monitoring) were implemented in both studies. Participants spent 14 and/or 70 consecutive days in a 6deg HDT position and did not engage in exercise. Subjects received weekly ocular examinations before, during, and after HDTBR. Ocular testing included: distance and near best-corrected visual acuity (BCVA), cycloplegic refraction, intraocular pressure (IOP) measurement, color vision, red dot test, modified Amsler grid test, confrontational visual field, color fundus photography and Spectral-domain OCT scans of the macula and the optic disc. Pre/post HDTBR differences between the two studies will be evaluated for BCVA, spherical equivalent, IOP, retinal nerve fiber layer (RNFL) thickness and macular OCT parameters. RESULTS: 16 (12 males and 4 females) and 6 (5 males and 1 female) subjects participated in the 14 and 70-day HDTBR studies, respectively. One subject participated in both studies. The demographic and ophthalmological characteristics of the 14-day HDTBR study have been presented elsewhere.2 In the 70- day study, subjects age averaged 39.5 +/- 7.8 years; pre- and post-HDTBR Goldmann IOP were, on average, 15.4 and 14.6 mmHg in the right eye, and 15.3 and 14.4 mmHg in the left eye, respectively; preand post-HDTBR Spectralis OCT (Heidelberg Engineering, GmbH, Heidelberg, Germany) average RNFL thickness were 103.8 and 106 µm in the right eye, and 103 and 104.3 µm in the left eye, respectively. In both studies, color vision, red dot test, modified Amsler grid test and confrontational visual field were within normal limits at all time points; no changes were detected on stereoscopic color optic disc photography. For the above outcomes, preliminary results of the pre/post HDTBR differences between the two studies will be presented at the 2015 Human Research Program Investigators' Workshop. CONCLUSIONS: Although 14-day HDTBR did not seem to induce clinically relevant ocular changes, (sup 2) a systematic evaluation and comparison with the 70-day HDTBR study results will elucidate whether the magnitude of ocular structural and functional changes is affected by the time spent in the recumbent position. Further research will also address the effects of integrated resistance and aerobic training during HDTBR on the ocular outcomes. REFERENCES: 1. Mader TH et al. Optic disc edema, globe flattening, choroidal folds, and hyperopic shifts observed in astronauts after long-duration space flight. Ophthalmology. 2011;118(10):2058-69. 2. Taibbi G et al. Ocular outcomes evaluation in a 14-day head-down bed rest study. Aviat Space Environ Med. 2014;85(10):983-92.
Liu, Ziyuan; Wang, Hongli; Fan, Dongsheng; Wang, Wei
2018-02-01
Recent studies revealing genetic connection of primary open angle glaucoma (POAG) and amyotrophic lateral sclerosis (ALS) have received particular attention. Exploring the evidence for common pathogenesis of these two progressive neurological disorders may assist in understanding the mechanism and searching for new treatment. Retinal nerve fiber layer (RNFL) defect and corresponding visual field (VF) impairment are well known neuropathy signs in glaucoma. In our study, thickness of certain retinal layer in ALS patients was analyzed to detect ganglion cell's soma and axon, and for first time visual field was examined for ALS. The correlation of retinal involvement and ALS progression were also investigated. The results were compared with those of POAG. The study may provide new knowledge for these two neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.
Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.
Simavli, Huseyin; Poon, Linda Yi-Chieh; Que, Christian J; Liu, Yingna; Akduman, Mustafa; Tsikata, Edem; de Boer, Johannes F; Chen, Teresa C
2017-06-01
To determine the diagnostic capability of spectral domain optical coherence tomography peripapillary retinal volume (RV) measurements. A total of 156 patients, 89 primary open-angle glaucoma and 67 normal subjects, were recruited. Spectral domain optical coherence tomography peripapillary RV was calculated for 4 quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing primary open-angle glaucoma. The pairwise comparisons of the best ROC curves for RV and retinal nerve fiber layer (RNFL) were performed. The artifact rates were analyzed. Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (P<0.05 for all quadrants). OCA1 and OCA2 had similar diagnostic performance, except for the inferior quadrant which was better for OCA1 (P=0.0033). The pairwise comparisons of the best ROC curves for RV and RNFL were not statistically significant. RV measurements had lower rates of artifacts at 7.4% while RNFL measurements had higher rates at 42.9%. Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable with that of RNFL parameters in glaucoma but with lower artifact rates.
Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma
Simavli, Huseyin; Poon, Linda Yi-Chieh; Que, Christian John; Liu, Yingna; Akduman, Mustafa; Tsikata, Edem; de Boer, Johannes F.; Chen, Teresa C.
2017-01-01
Purpose To determine the diagnostic capability of spectral domain optical coherence tomography (SD-OCT) peripapillary retinal volume (RV) measurements. Materials and Methods A total of 156 patients, 89 primary open angle (POAG) and 67 normal subjects, were recruited. SD-OCT peripapillary RV was calculated for four quadrants using 3 annuli of varying scan circle diameters: outer circumpapillary annuli of circular grids 1, 2, and 3 (OCA1, OCA2, OCA3). Area under the receiver operating characteristic (AUROC) curves and pairwise comparisons of receiver operating characteristic (ROC) curves were performed to determine which quadrants were best for diagnosing POAG. The pairwise comparisons of the best ROC curves for RV and RNFL were performed. The artifact rates were analyzed. Results Pairwise comparisons showed that the smaller annuli OCA1 and OCA2 had better diagnostic performance than the largest annulus OCA3 (p<0.05 for all quadrants). OCA1 and OCA2 had similar diagnostic performance, except for the inferior quadrant which was better for OCA1 (p=0.0033).The pairwise comparisons of the best ROC curves for RV and RNFL were not statistically significant. Retinal volume measurements had lower rates of artifacts at 7.4% while RNFL measurements had higher rates at 42.9%. Conclusion Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients. The inferior quadrant of peripapillary annulus OCA1 demonstrated the best diagnostic capability for both glaucoma and early glaucoma. The diagnostic ability of RV is comparable to that of RNFL parameters in glaucoma but with lower artifact rates. PMID:28079657
Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C
2011-09-09
To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.
Holló, Gábor
2016-12-01
Myelinated retinal nerve fibers (MRNF) represent an asymptomatic developmental anomaly in which myelin sheaths extend to a group of retinal nerve fibers along their intraocular portion. The additional volume of the myelin sheaths causes displacement of the axons toward the vitreous body. We investigated the effect of localized MRNF on peripapillary vessel density measurement results using optical coherence tomography (OCT) angiography. Peripapillary angioflow density measurements (PAFD, % of the analyzed retinal area) were made with the AngioVue OCT (Optovue Inc., Fremont, USA). In both cases, the predominant position of MRNF was inferonasal to the disk. Vessel density was clearly greater in the area of the MRNF than in the surrounding retina in the optic nerve head (ONH) level, but it was lower than in the surrounding retina in the retinal nerve fiber layer (RNFL) level. In the ONH level, PAFD was higher in the MRNF area than in the spatially corresponding superonasal area (Case 1: 64.6 vs. 57.6 %; Case 2: 65.8 vs. 56.3 %). In contrast, in the RNFL level, PAFD was lower in the MRNF area than in the corresponding superonasal area (Case 1: 60.1 vs. 65.4 %; Case 2: 46.5 vs. 58.5 %). Our cases show that the effect of MRNF on OCT angiography vessel density is different in the different measurement layers. Clinicians may separate decreased vessel density caused by anterior RNFL displacement in MRNF areas from that caused by nerve fiber damage in optic neuropathies by evaluating PAFD in both the ONH and RNFL levels.
Cho, Hyun-Kyung; Lee, Min Gyu; Kee, Changwon
2018-06-12
This study aimed to investigate the association of the frequency of optic disk hemorrhage (DH) and progression of normal tension glaucoma (NTG) between each group based on the location of the initial retinal nerve fiber layer (RNFL) defect. In this retrospective, observational cohort study, 142 NTG patients who underwent more than 5 reliable visual field tests with initial superior hemifield (group 2, n = 51), inferior hemifield (group 1, n = 44), or both hemifield (group 3, n = 47) defects were included. The number of DHs was inspected in serial optic disk photographs by 2 different ophthalmologists. Progression rates, which are the slope of mean thresholds from the 52 points, were calculated using a linear mixed effect model. The mean follow-up period was 8.19 ± 3.30 years. DHs related with the initial RNFL defect occurred significantly more frequently in group 2 (35 in inferior hemifield) than in group 1 (6 in superior hemifield) (p = 0.009) or group 3 (6 in inferior hemifield) (p = 0.006). The progression rate in group 2 was significantly faster than in group 1 (p = 0.019) or the superior hemifield of group 3 (p = 0.001). The progression rate of subjects showing recurrent DH was significantly faster than those showing single DH from all groups (-0.5460 vs. -0.2867 dB/year, p = 0.0053). More careful examination and caution are required when NTG patients show recurrent DH in the inferior hemifield related to the initial RNFL defect. © 2018 S. Karger AG, Basel.
Raza, Ali S.; Zhang, Xian; De Moraes, Carlos G. V.; Reisman, Charles A.; Liebmann, Jeffrey M.; Ritch, Robert; Hood, Donald C.
2014-01-01
Purpose. To improve the detection of glaucoma, techniques for assessing local patterns of damage and for combining structure and function were developed. Methods. Standard automated perimetry (SAP) and frequency-domain optical coherence tomography (fdOCT) data, consisting of macular retinal ganglion cell plus inner plexiform layer (mRGCPL) as well as macular and optic disc retinal nerve fiber layer (mRNFL and dRNFL) thicknesses, were collected from 52 eyes of 52 healthy controls and 156 eyes of 96 glaucoma suspects and patients. In addition to generating simple global metrics, SAP and fdOCT data were searched for contiguous clusters of abnormal points and converted to a continuous metric (pcc). The pcc metric, along with simpler methods, was used to combine the information from the SAP and fdOCT. The performance of different methods was assessed using the area under receiver operator characteristic curves (AROC scores). Results. The pcc metric performed better than simple global measures for both the fdOCT and SAP. The best combined structure-function metric (mRGCPL&SAP pcc, AROC = 0.868 ± 0.032) was better (statistically significant) than the best metrics for independent measures of structure and function. When SAP was used as part of the inclusion and exclusion criteria, AROC scores increased for all metrics, including the best combined structure-function metric (AROC = 0.975 ± 0.014). Conclusions. A combined structure-function metric improved the detection of glaucomatous eyes. Overall, the primary sources of value-added for glaucoma detection stem from the continuous cluster search (the pcc), the mRGCPL data, and the combination of structure and function. PMID:24408977
Predictors of vision impairment in Multiple Sclerosis.
Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo
2018-01-01
Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.
Lee, Haeng-Jin; Kang, Tae-Seen; Kwak, Baek-Soo; Jo, Young-Joon; Kim, Jung-Yeul
2017-08-01
To evaluate the effects of panretinal photocoagulation on spectral domain optical coherence tomography measurements in diabetic retinopathy by comparing the thicknesses of the central macula, retinal nerve fiber layer, and ganglion cell layer, we used a Cirrus HD OCT® (Carl Zeiss Meditec, Dublin, CA, USA) in normal and diabetic retinopathy cohorts. We analyzed patients who visited our retinal clinic between May 2013 and July 2014. The patients were classified into four groups: normal (Group A), diabetes without diabetic retinopathy (Group B), severe nonproliferative or proliferative diabetic retinopathy (Group C), and at least 3 years after panretinal photocoagulation treatment (Group D). The mean thicknesses of the macula, retinal nerve fiber layer, and ganglion cell layer in each group were compared by measuring a macular cube 512 × 128 scan and an optic disc cube 200 × 200 scan twice. In total, 154 patients were enrolled. The mean thickness of the central macula in groups A to D was 257.2, 256.8, 257.4, and 255.6 µm, respectively, and did not differ significantly. The mean thickness of the RNFL in group A to D was 96.8, 96.5, 97.2, and 92.8 µm, respectively, and was significantly lower in group D (decreased in the inferior, superior, and nasal sectors, but increased in the temporal). The mean thickness of the ganglion cell layer was also significantly lower in group D (A, 84.5 µm; B, 84.4 µm; C, 82.5 µm; D, 78.5 µm). The mean thicknesses of the retinal nerve fiber and ganglion cell layers were decreased significantly in eyes with diabetic eye disease treated with panretinal photocoagulation compared to normal or eyes with diabetic eye disease that had not been laser-treated. Laser treatment might have altered the thickness of the inner layer of the retina, and such changes should be considered in diabetic retinopathy patients after panretinal photocoagulation treatment.
Iutaka, Natalia A; Grochowski, Rubens A; Kasahara, Niro
2017-01-01
To evaluate the correlation between visual field index (VFI) and both structural and functional measures of the optic disc in primary open angle glaucoma patients and suspects. In this retrospective study, 162 glaucoma patients and suspects underwent standard automated perimetry (SAP), retinography, and retinal nerve fiber layer (RNFL) measurement. The optic disc was stratified according to the vertical cup/disc ratio (C/D) and sorted by the disc damage likelihood scale (DDLS). RNFL was measured with the optical coherence tomography. The VFI perimetry was correlated with the mean deviation (MD) and pattern standard deviation (PSD) obtained by SAP, and structural parameters by Pearson's correlation coefficients. VFI displayed strong correlation with MD ( R = 0.959) and PSD ( R = -0.744). The linear correlations between VFI and structural measures including C/D ( R = -0.179, P = 0.012), DDLS ( R = -0.214, P = 0.006), and RNFL ( R = 0.416, P < 0.001) were weak but statistically significant. VFI showed a strong correlation with MD and PSD but demonstrated a weak correlation with structural measures. It can possibly be used as a marker for functional impairment severity in patients with glaucoma.
Najjar, Raymond P; Sharma, Sourabh; Atalay, Eray; Rukmini, Annadata V; Sun, Christopher; Lock, Jing Zhan; Baskaran, Mani; Perera, Shamira A; Husain, Rahat; Lamoureux, Ecosse; Gooley, Joshua J; Aung, Tin; Milea, Dan
2018-03-21
To evaluate the ability of chromatic pupillometry to reveal abnormal pupillary responses to light in patients with early-stage primary open-angle glaucoma (POAG) and to test whether the degree of pupillometric impairment correlates with structural hallmarks of optic nerve damage in the disease. Cross-sectional study. Forty-six patients with early-stage POAG (63.4±8.3 years, 63% male, 87% ethnic-Chinese) and 90 age-matched healthy controls (61.4±8.6 years, 34% male, 89% ethnic-Chinese). Patients with POAG had a visual field mean deviation (VFMD) of -6 decibels or better on automated perimetry. Each participant underwent a monocular 2-minute exposure to blue light (462 nm) followed by another 2-minute exposure to red light (638 nm) using a modified Ganzfeld dome equipped with a light-emitting diode lighting system. The light stimuli intensity was increased logarithmically to evaluate the combined extrinsic and intrinsic response of intrinsically photosensitive retinal ganglion cells (ipRGCs). Light-induced changes in horizontal pupil diameter were assessed monocularly using infrared pupillography. Baseline-adjusted, light-induced pupillary constriction amplitudes were calculated, and individual irradiance-response curves were constructed for each stimulus. Pupillary constriction amplitudes were compared between groups and across light intensities using a linear mixed model analysis. The linear relationship between pupillometric parameters and different structural and functional features of glaucoma was assessed using Pearson's correlation analysis. Light-induced pupillary constriction was reduced in patients with early-stage POAG compared with controls at moderate to high irradiances (≥11 Log photons/cm 2 /s) of blue (P = 0.003) and red (P < 0.001) light. Maximal pupillary constriction amplitude was correlated with retinal nerve fiber layer thickness (RNFL) thickness (blue: r = 0.51, P < 0.001; red: r = 0.45, P = 0.002) in patients with POAG but not in controls. Conversely, pupillometric parameters were not correlated with visual field scores in patients with early-stage POAG. Patients with early-stage POAG exhibit reduced pupillary responses to moderate and high irradiances of blue and red lights. This wavelength-independent functional alteration correlates with structural thinning of the RNFL and could be the consequence of dysfunction or loss of melanopsin expressing ipRGCs in the early stages of the disease. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Retinal Thickening and Photoreceptor Loss in HIV Eyes without Retinitis.
Arcinue, Cheryl A; Bartsch, Dirk-Uwe; El-Emam, Sharif Y; Ma, Feiyan; Doede, Aubrey; Sharpsten, Lucie; Gomez, Maria Laura; Freeman, William R
2015-01-01
To determine the presence of structural changes in HIV retinae (i.e., photoreceptor density and retinal thickness in the macula) compared with age-matched HIV-negative controls. Cohort of patients with known HIV under CART (combination Antiretroviral Therapy) treatment were examined with a flood-illuminated retinal AO camera to assess the cone photoreceptor mosaic and spectral-domain optical coherence tomography (SD-OCT) to assess retinal layers and retinal thickness. Twenty-four eyes of 12 patients (n = 6 HIV-positive and 6 HIV-negative) were imaged with the adaptive optics camera. In each of the regions of interest studied (nasal, temporal, superior, inferior), the HIV group had significantly less mean cone photoreceptor density compared with age-matched controls (difference range, 4,308-6,872 cones/mm2). A different subset of forty eyes of 20 patients (n = 10 HIV-positive and 10 HIV-negative) was included in the retinal thickness measurements and retinal layer segmentation with the SD-OCT. We observed significant thickening in HIV positive eyes in the total retinal thickness at the foveal center, and in each of the three horizontal B-scans (through the macular center, superior, and inferior to the fovea). We also noted that the inner retina (combined thickness from ILM through RNFL to GCL layer) was also significantly thickened in all the different locations scanned compared with HIV-negative controls. Our present study shows that the cone photoreceptor density is significantly reduced in HIV retinae compared with age-matched controls. HIV retinae also have increased macular retinal thickness that may be caused by inner retinal edema secondary to retinovascular disease in HIV. The interaction of photoreceptors with the aging RPE, as well as possible low-grade ocular inflammation causing diffuse inner retinal edema, may be the key to the progressive vision changes in HIV-positive patients without overt retinitis.
Hou, Huiyuan; Moghimi, Sasan; Zangwill, Linda M; Shoji, Takuhei; Ghahari, Elham; Manalastas, Patricia Isabel C; Penteado, Rafaella C; Weinreb, Robert N
2018-03-23
To investigate inter-eye retinal vessel density asymmetry in healthy, glaucoma suspect, and mild to moderate glaucoma subjects, and its potential utility for early detection of glaucomatous damage. Cross-sectional study. 153 subjects including 55 healthy, 32 glaucoma suspect, and 66 glaucoma subjects enrolled in the Diagnostic Innovations in Glaucoma Study(DIGS). Vessel density was obtained from optical coherence tomography angiography (OCT-A) macular and optic nerve head scans. Thickness of peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell complex (mGCC) was measured with spectral-domain optical coherence tomography (SD-OCT) scans. Inter-eye asymmetry was calculated by taking the absolute value of difference in vessel density and thickness between the right and left eyes. Inter-eye retinal vessel density asymmetry parameters were significantly different among the three groups. Glaucoma suspects had significantly higher peripapillary and macular inter-eye vessel density asymmetries compared to healthy groups in univariate (1.1% vs. 2.0%, P=0.014 and 1.2% vs. 2.5%, P=0.027, respectively) and multivariate analyses (P=0.007 and 0.038, respectively). No significant differences in asymmetry of thickness parameters were found between glaucoma suspect and healthy groups (all P> 0.718). However significant differences in asymmetry of thickness parameters between glaucoma suspects and glaucoma patients (P<0.01) were found for all parameters. Inter-eye vessel density asymmetry can be quantified by OCT-A measurement. Glaucoma suspects have significantly greater vessel density asymmetry than healthy eyes. Longitudinal studies are needed to better characterize the relationship of vessel density asymmetry with the development and progression of glaucoma. Copyright © 2018 Elsevier Inc. All rights reserved.
Bizios, Dimitrios; Heijl, Anders; Hougaard, Jesper Leth; Bengtsson, Boel
2010-02-01
To compare the performance of two machine learning classifiers (MLCs), artificial neural networks (ANNs) and support vector machines (SVMs), with input based on retinal nerve fibre layer thickness (RNFLT) measurements by optical coherence tomography (OCT), on the diagnosis of glaucoma, and to assess the effects of different input parameters. We analysed Stratus OCT data from 90 healthy persons and 62 glaucoma patients. Performance of MLCs was compared using conventional OCT RNFLT parameters plus novel parameters such as minimum RNFLT values, 10th and 90th percentiles of measured RNFLT, and transformations of A-scan measurements. For each input parameter and MLC, the area under the receiver operating characteristic curve (AROC) was calculated. There were no statistically significant differences between ANNs and SVMs. The best AROCs for both ANN (0.982, 95%CI: 0.966-0.999) and SVM (0.989, 95% CI: 0.979-1.0) were based on input of transformed A-scan measurements. Our SVM trained on this input performed better than ANNs or SVMs trained on any of the single RNFLT parameters (p < or = 0.038). The performance of ANNs and SVMs trained on minimum thickness values and the 10th and 90th percentiles were at least as good as ANNs and SVMs with input based on the conventional RNFLT parameters. No differences between ANN and SVM were observed in this study. Both MLCs performed very well, with similar diagnostic performance. Input parameters have a larger impact on diagnostic performance than the type of machine classifier. Our results suggest that parameters based on transformed A-scan thickness measurements of the RNFL processed by machine classifiers can improve OCT-based glaucoma diagnosis.
Sehi, M; Bhardwaj, N; Chung, Y S; Greenfield, D S
2012-12-01
The objective of this study is to assess whether baseline optic nerve head (ONH) topography and retinal nerve fiber layer thickness (RNFLT) are predictive of glaucomatous visual-field progression in glaucoma suspect (GS) and glaucomatous eyes, and to calculate the level of risk associated with each of these parameters. Participants with ≥28 months of follow-up were recruited from the longitudinal Advanced Imaging for Glaucoma Study. All eyes underwent standard automated perimetry (SAP), confocal scanning laser ophthalmoscopy (CSLO), time-domain optical coherence tomography (TDOCT), and scanning laser polarimetry using enhanced corneal compensation (SLPECC) every 6 months. Visual-field progression was assessed using pointwise linear-regression analysis of SAP sensitivity values (progressor) and defined as significant sensitivity loss of >1 dB/year at ≥2 adjacent test locations in the same hemifield at P<0.01. Cox proportional hazard ratios (HR) were calculated to determine the predictive ability of baseline ONH and RNFL parameters for SAP progression using univariate and multivariate models. Seventy-three eyes of 73 patients (43 GS and 30 glaucoma, mean age 63.2±9.5 years) were enrolled (mean follow-up 51.5±11.3 months). Four of 43 GS (9.3%) and 6 of 30 (20%) glaucomatous eyes demonstrated progression. Mean time to progression was 50.8±11.4 months. Using multivariate models, abnormal CSLO temporal-inferior Moorfields classification (HR=3.76, 95% confidence interval (CI): 1.02-6.80, P=0.04), SLPECC inferior RNFLT (per -1 μm, HR=1.38, 95% CI: 1.02-2.2, P=0.02), and TDOCT inferior RNFLT (per -1 μm, HR=1.11, 95% CI: 1.04-1.2, P=0.001) had significant HRs for SAP progression. Abnormal baseline ONH topography and reduced inferior RNFL are predictive of SAP progression in GS and glaucomatous eyes.
Sehi, M; Bhardwaj, N; Chung, Y S; Greenfield, D S
2012-01-01
Purpose The objective of this study is to assess whether baseline optic nerve head (ONH) topography and retinal nerve fiber layer thickness (RNFLT) are predictive of glaucomatous visual-field progression in glaucoma suspect (GS) and glaucomatous eyes, and to calculate the level of risk associated with each of these parameters. Methods Participants with ≥28 months of follow-up were recruited from the longitudinal Advanced Imaging for Glaucoma Study. All eyes underwent standard automated perimetry (SAP), confocal scanning laser ophthalmoscopy (CSLO), time-domain optical coherence tomography (TDOCT), and scanning laser polarimetry using enhanced corneal compensation (SLPECC) every 6 months. Visual-field progression was assessed using pointwise linear-regression analysis of SAP sensitivity values (progressor) and defined as significant sensitivity loss of >1 dB/year at ≥2 adjacent test locations in the same hemifield at P<0.01. Cox proportional hazard ratios (HR) were calculated to determine the predictive ability of baseline ONH and RNFL parameters for SAP progression using univariate and multivariate models. Results Seventy-three eyes of 73 patients (43 GS and 30 glaucoma, mean age 63.2±9.5 years) were enrolled (mean follow-up 51.5±11.3 months). Four of 43 GS (9.3%) and 6 of 30 (20%) glaucomatous eyes demonstrated progression. Mean time to progression was 50.8±11.4 months. Using multivariate models, abnormal CSLO temporal-inferior Moorfields classification (HR=3.76, 95% confidence interval (CI): 1.02–6.80, P=0.04), SLPECC inferior RNFLT (per −1 μm, HR=1.38, 95% CI: 1.02–2.2, P=0.02), and TDOCT inferior RNFLT (per −1 μm, HR=1.11, 95% CI: 1.04–1.2, P=0.001) had significant HRs for SAP progression. Conclusion Abnormal baseline ONH topography and reduced inferior RNFL are predictive of SAP progression in GS and glaucomatous eyes. PMID:23060026
Automated choroid segmentation based on gradual intensity distance in HD-OCT images.
Chen, Qiang; Fan, Wen; Niu, Sijie; Shi, Jiajia; Shen, Honglie; Yuan, Songtao
2015-04-06
The choroid is an important structure of the eye and plays a vital role in the pathology of retinal diseases. This paper presents an automated choroid segmentation method for high-definition optical coherence tomography (HD-OCT) images, including Bruch's membrane (BM) segmentation and choroidal-scleral interface (CSI) segmentation. An improved retinal nerve fiber layer (RNFL) complex removal algorithm is presented to segment BM by considering the structure characteristics of retinal layers. By analyzing the characteristics of CSI boundaries, we present a novel algorithm to generate a gradual intensity distance image. Then an improved 2-D graph search method with curve smooth constraints is used to obtain the CSI segmentation. Experimental results with 212 HD-OCT images from 110 eyes in 66 patients demonstrate that the proposed method can achieve high segmentation accuracy. The mean choroid thickness difference and overlap ratio between our proposed method and outlines drawn by experts was 6.72µm and 85.04%, respectively.
Optic nerve head and fibre layer imaging for diagnosing glaucoma.
Michelessi, Manuele; Lucenteforte, Ersilia; Oddone, Francesco; Brazzelli, Miriam; Parravano, Mariacristina; Franchi, Sara; Ng, Sueko M; Virgili, Gianni
2015-11-30
The diagnosis of glaucoma is traditionally based on the finding of optic nerve head (ONH) damage assessed subjectively by ophthalmoscopy or photography or by corresponding damage to the visual field assessed by automated perimetry, or both. Diagnostic assessments are usually required when ophthalmologists or primary eye care professionals find elevated intraocular pressure (IOP) or a suspect appearance of the ONH. Imaging tests such as confocal scanning laser ophthalmoscopy (HRT), optical coherence tomography (OCT) and scanning laser polarimetry (SLP, as used by the GDx instrument), provide an objective measure of the structural changes of retinal nerve fibre layer (RNFL) thickness and ONH parameters occurring in glaucoma. To determine the diagnostic accuracy of HRT, OCT and GDx for diagnosing manifest glaucoma by detecting ONH and RNFL damage. We searched several databases for this review. The most recent searches were on 19 February 2015. We included prospective and retrospective cohort studies and case-control studies that evaluated the accuracy of OCT, HRT or the GDx for diagnosing glaucoma. We excluded population-based screening studies, since we planned to consider studies on self-referred people or participants in whom a risk factor for glaucoma had already been identified in primary care, such as elevated IOP or a family history of glaucoma. We only considered recent commercial versions of the tests: spectral domain OCT, HRT III and GDx VCC or ECC. We adopted standard Cochrane methods. We fitted a hierarchical summary ROC (HSROC) model using the METADAS macro in SAS software. After studies were selected, we decided to use 2 x 2 data at 0.95 specificity or closer in meta-analyses, since this was the most commonly-reported level. We included 106 studies in this review, which analysed 16,260 eyes (8353 cases, 7907 controls) in total. Forty studies (5574 participants) assessed GDx, 18 studies (3550 participants) HRT, and 63 (9390 participants) OCT, with 12 of these studies comparing two or three tests. Regarding study quality, a case-control design in 103 studies raised concerns as it can overestimate accuracy and reduce the applicability of the results to daily practice. Twenty-four studies were sponsored by the manufacturer, and in 15 the potential conflict of interest was unclear.Comparisons made within each test were more reliable than those between tests, as they were mostly based on direct comparisons within each study.The Nerve Fibre Indicator yielded the highest accuracy (estimate, 95% confidence interval (CI)) among GDx parameters (sensitivity: 0.67, 0.55 to 0.77; specificity: 0.94, 0.92 to 0.95). For HRT measures, the Vertical Cup/Disc (C/D) ratio (sensitivity: 0.72, 0.60 to 0.68; specificity: 0.94, 0.92 to 0.95) was no different from other parameters. With OCT, the accuracy of average RNFL retinal thickness was similar to the inferior sector (0.72, 0.65 to 0.77; specificity: 0.93, 0.92 to 0.95) and, in different studies, to the vertical C/D ratio.Comparing the parameters with the highest diagnostic odds ratio (DOR) for each device in a single HSROC model, the performance of GDx, HRT and OCT was remarkably similar. At a sensitivity of 0.70 and a high specificity close to 0.95 as in most of these studies, in 1000 people referred by primary eye care, of whom 200 have manifest glaucoma, such as in those who have already undergone some functional or anatomic testing by optometrists, the best measures of GDx, HRT and OCT would miss about 60 cases out of the 200 patients with glaucoma, and would incorrectly refer 50 out of 800 patients without glaucoma. If prevalence were 5%, e.g. such as in people referred only because of family history of glaucoma, the corresponding figures would be 15 patients missed out of 50 with manifest glaucoma, avoiding referral of about 890 out of 950 non-glaucomatous people.Heterogeneity investigations found that sensitivity estimate was higher for studies with more severe glaucoma, expressed as worse average mean deviation (MD): 0.79 (0.74 to 0.83) for MD < -6 db versus 0.64 (0.60 to 0.69) for MD ≥ -6 db, at a similar summary specificity (0.93, 95% CI 0.92 to 0.94 and, respectively, 0.94; 95% CI 0.93 to 0.95; P < 0.0001 for the difference in relative DOR). The accuracy of imaging tests for detecting manifest glaucoma was variable across studies, but overall similar for different devices. Accuracy may have been overestimated due to the case-control design, which is a serious limitation of the current evidence base.We recommend that further diagnostic accuracy studies are carried out on patients selected consecutively at a defined step of the clinical pathway, providing a description of risk factors leading to referral and bearing in mind the consequences of false positives and false negatives in the setting in which the diagnostic question is made. Future research should report accuracy for each threshold of these continuous measures, or publish raw data.
Holló, Gábor
2017-07-01
To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.
Vidotti, Vanessa G; Costa, Vital P; Silva, Fabrício R; Resende, Graziela M; Cremasco, Fernanda; Dias, Marcelo; Gomi, Edson S
2012-06-15
Purpose. To investigate the sensitivity and specificity of machine learning classifiers (MLC) and spectral domain optical coherence tomography (SD-OCT) for the diagnosis of glaucoma. Methods. Sixty-two patients with early to moderate glaucomatous visual field damage and 48 healthy individuals were included. All subjects underwent a complete ophthalmologic examination, achromatic standard automated perimetry, and RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, California, USA). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters. Subsequently, the following MLCs were tested: Classification Tree (CTREE), Random Forest (RAN), Bagging (BAG), AdaBoost M1 (ADA), Ensemble Selection (ENS), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Naive-Bayes (NB), and Support Vector Machine (SVM). Areas under the ROC curves (aROCs) obtained for each parameter and each MLC were compared. Results. The mean age was 57.0±9.2 years for healthy individuals and 59.9±9.0 years for glaucoma patients (p=0.103). Mean deviation values were -4.1±2.4 dB for glaucoma patients and -1.5±1.6 dB for healthy individuals (p<0.001). The SD-OCT parameters with the greater aROCs were inferior quadrant (0.813), average thickness (0.807), 7 o'clock position (0.765), and 6 o'clock position (0.754). The aROCs from classifiers varied from 0.785 (ADA) to 0.818 (BAG). The aROC obtained with BAG was not significantly different from the aROC obtained with the best single SD-OCT parameter (p=0.93). Conclusions. The SD-OCT showed good diagnostic accuracy in a group of patients with early glaucoma. In this series, MLCs did not improve the sensitivity and specificity of SD-OCT for the diagnosis of glaucoma.
Correlation between CHA2DS2-VASc Score and Glaucoma Treatment and Prognosis.
Pikkel, Yoav Y; Krebs, Daniel; Igal, Vadim; Sharabi-Nov, Adi; Epstein, Irena; Pikkel, Joseph
2018-01-01
To find if CHA 2 DS 2 -VASc scale can accurately predict the treatment, prognosis, and outcome for primary open-angle glaucoma (POAG). A survey of 250,000 patient years was taken, using the records of the Ophthalmology Department at Ziv Medical Center. Data was collected regarding the retinal nerve fiber layer (RNFL), visual field (VF), line of treatment (LOT) of glaucoma, and all the data needed to accurately calculate CHA 2 DS 2 -VASc score for each patient. Sixty-seven patients were included in the statistical analysis. The mean age was 72.5 years. The mean CHA 2 DS 2 -VASc score was 3.27 + -1.7. Positive Pearson's correlation coefficients were found for LOT and CHA 2 DS 2 -VASc score, 0.35, and for RNFL grade and CHA2DS2-VASc score, 0.37. The correlation was negative for RNFL width and CHA2DS2-VASc score, -0.35. CHA 2 DS 2 -VASc score was shown to be correlated with glaucoma. This correlation was manifested positively by the LOT needed to stop glaucoma progression, with higher CHA 2 DS 2 -VASc scores correlated with more aggressive treatment. Since glaucoma is a disease with a progressing nature, it is important to treat patients aggressively on one hand, while offering the most benign treatment as possible on the other hand. Modification of the CHA 2 DS 2 -VASc score could achieve an even higher correlation.
Study of long term structural and functional changes in medically controlled glaucoma
Pandey, Achyut N; Sujata, S
2014-01-01
AIM Prospectively analyze the long term structural and functional changes in patients of primary open angle glaucoma (POAG) receiving medical therapy (beta blockers and non beta blockers). In this study an attempt has been made to evaluate whether medical reduction of IOP prevents or delays the progression of glaucomatous visual field loss and/or optic nerve damage in patients with open angle glaucoma. METHODS Study conducted over a period of 27 months, at a tertiary eye care hospital including both eyes of 40 patients with POAG. Group 1 (20 patients, 40 eyes) received beta-blockers, and Group 2 (20 patients, 40 eyes) received non-beta-blockers. Each patient underwent intraocular pressure measurement, best corrected visual acuity, slit-lamp, fundus examination, gonioscopy, central corneal thickness, visual field assessment by Humphrey automated perimetry and retinal nerve fibre layer thickness by Stratus optical coherence tomography at baseline and at two subsequent visits. The average time interval between each visit was 10-11 months. The statistical analysis was done using one-way analysis of variance (ANOVA). Post-hoc test, using tukey' method were adopted. Probablity (P) value of 0.05 or less was considered to be statistically significant. RESULTS A total of 80 eyes of 40 patients of POAG were enrolled, 24 males, 16 females, age group 50-80 years. In both beta and non beta blocker group, reduction (improvement) in mean IOP from initial levels to the levels achieved at the 2nd and 3rd visits was statistically significant. One way ANOVA (df=2), fisher f value=11.64, P=0.000, one way ANOVA (df=3), fisher f value=35.61, P=0.000. Both mean deviation (MD) and pattern standard deviation (PSD) in both beta and non beta blockers at different visits were not statistically significant. Retinal nerve fibre layer thickness (RNFL) -only mean inferior retinal nerve fibre layer, the difference between the mean value in beta and non beta blocker groupwere statistically significant. [unpaired t test value (df=78) =2.27, P=0.03]. Side effects with beta blocker were conjunctival hyperemia (10%), burning (5%), and conjunctival hyperemia (5%) in non beta blockers. CONCLUSION Non-beta-blockers are as effective as beta-blockers in bringing about a significant lowering of intraocular pressure to the normal range, and in preventing progressive damage to the visual fields and retinal nerve fibre layer. The absence of systemic side effects and superior IOP lowering efficacy has made non beta-blockers attractive for first line therapy for the treatment of glaucoma worldwide. PMID:24634878
Study of long term structural and functional changes in medically controlled glaucoma.
Pandey, Achyut N; Sujata, S
2014-01-01
Prospectively analyze the long term structural and functional changes in patients of primary open angle glaucoma (POAG) receiving medical therapy (beta blockers and non beta blockers). In this study an attempt has been made to evaluate whether medical reduction of IOP prevents or delays the progression of glaucomatous visual field loss and/or optic nerve damage in patients with open angle glaucoma. Study conducted over a period of 27 months, at a tertiary eye care hospital including both eyes of 40 patients with POAG. Group 1 (20 patients, 40 eyes) received beta-blockers, and Group 2 (20 patients, 40 eyes) received non-beta-blockers. Each patient underwent intraocular pressure measurement, best corrected visual acuity, slit-lamp, fundus examination, gonioscopy, central corneal thickness, visual field assessment by Humphrey automated perimetry and retinal nerve fibre layer thickness by Stratus optical coherence tomography at baseline and at two subsequent visits. The average time interval between each visit was 10-11 months. The statistical analysis was done using one-way analysis of variance (ANOVA). Post-hoc test, using tukey' method were adopted. Probablity (P) value of 0.05 or less was considered to be statistically significant. A total of 80 eyes of 40 patients of POAG were enrolled, 24 males, 16 females, age group 50-80 years. In both beta and non beta blocker group, reduction (improvement) in mean IOP from initial levels to the levels achieved at the 2nd and 3rd visits was statistically significant. One way ANOVA (df=2), fisher f value=11.64, P=0.000, one way ANOVA (df=3), fisher f value=35.61, P=0.000. Both mean deviation (MD) and pattern standard deviation (PSD) in both beta and non beta blockers at different visits were not statistically significant. Retinal nerve fibre layer thickness (RNFL) -only mean inferior retinal nerve fibre layer, the difference between the mean value in beta and non beta blocker groupwere statistically significant. [unpaired t test value (df=78) =2.27, P=0.03]. Side effects with beta blocker were conjunctival hyperemia (10%), burning (5%), and conjunctival hyperemia (5%) in non beta blockers. Non-beta-blockers are as effective as beta-blockers in bringing about a significant lowering of intraocular pressure to the normal range, and in preventing progressive damage to the visual fields and retinal nerve fibre layer. The absence of systemic side effects and superior IOP lowering efficacy has made non beta-blockers attractive for first line therapy for the treatment of glaucoma worldwide.
Three-dimensional spectral domain optical coherence tomography in X linked foveal retinoschisis
Saxena, Sandeep; Manisha; Meyer, Carsten H
2013-01-01
Spectral domain optical coherence tomography (SD-OCT) was performed in two cases of bilateral X linked foveal retinoschisis of different age groups. On fundus examination spoke wheel and honeycomb pattern of cysts were observed along with retinal nerve fibre layer (RNFL) defects. On SD-OCT, schisis was observed in the outer plexiform layer. External limiting membrane disruption was observed in the subfoveal area, along with disruption of outer nuclear layer (ONL) and inner–outer segment junction. Elevation of ONL due to tractional pull of central palisade was a novel observation. Retinoschisis extended beyond the optic disc up to the nasal region. Extracted RNFL tomogram presented an unprecedented visualisation of schisis along 360° of the optic disc. Tractional elevation in the foveal area and schisis involving nasal region, not observed upon clinical examination, was highlighted on SD-OCT. This investigative modality is an important adjunct in the assessment of foveal retinoschisis. PMID:23563673
Moster, Stephen; Wilson, James A; Galetta, Steven L; Balcer, Laura J
2014-08-15
We investigated the King-Devick (K-D) test of rapid number naming as a visual performance measure in a cohort of patients with multiple sclerosis (MS). In this cross-sectional study, 81 patients with MS and 20 disease-free controls from an ongoing study of visual outcomes underwent K-D testing. A test of rapid number naming, K-D requires saccadic eye movements as well as intact vision, attention and concentration. To perform the K-D test, participants are asked to read numbers aloud as quickly as possible from three test cards; the sum of the three test card times in seconds constitutes the summary score. High-contrast visual acuity (VA), low-contrast letter acuity (1.25% and 2.5% levels), retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), MS Functional Composite (MSFC) and vision-specific quality of life (QOL) measures (25-Item NEI Visual Functioning Questionnaire [NEI-VFQ-25] and 10-Item Neuro-Ophthalmic Supplement) were also assessed. K-D time scores in the MS cohort (total time to read the three test cards) were significantly higher (worse) compared to those for disease-free controls (P=0.003, linear regression, accounting for age). Within the MS cohort, higher K-D scores were associated with worse scores for the NEI-VFQ-25 composite (P<0.001), 10-Item Neuro-Ophthalmic Supplement (P<0.001), binocular low-contrast acuity (2.5%, 1.25%, P<0.001, and high-contrast VA (P=0.003). Monocular low-contrast vision scores (P=0.001-0.009) and RNFL thickness (P=0.001) were also reduced in eyes of patients with worse K-D scores (GEE models accounting for age and within-patient, inter-eye correlations). Patients with a history of optic neuritis (ON) had increased (worse) K-D scores. Patients who classified their work disability status as disabled (receiving disability pension) did worse on K-D testing compared to those working full-time (P=0.001, accounting for age). The K-D test, a <2 minute bedside test of rapid number naming, is associated with visual dysfunction, neurologic impairment, and reduced vision-specific QOL in patients with MS. Scores reflect work disability as well as structural changes as measured by OCT imaging. History of ON and abnormal binocular acuities were associated with worse K-D scores, suggesting that abnormalities detected by K-D may go along with afferent dysfunction in MS patients. A brief test that requires saccadic eye movements, K-D should be considered for future MS trials as a rapid visual performance measure. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zwick, Harry; Stuck, Bruce E.; Akers, A.; Edsall, Peter; DiCarlo, Cheryl D.; Lund, David J.
2005-04-01
Laser induced retinal damage may involve primary injury to the central retina and secondary damage, including intraretinal scar formation (IRSF) retinal traction (RT) and retinal nerve fiber layer injury (RNFL). We have evaluated these laser induced retinal pathologies with MFERG in non-human primates (NHPs) with a Veris (4.9) MFERG system 103 Hexagons, centered on the macula with non-scaled arrays and in one NHP with a 2-frame/M-step sequence to assess long term exposure effects within the RNFL. Chemical restraint was achieved using Ketamine stability HCL (10 mg/kg IM) and Propofol (0.5 mg-1.2/Kg/min via syringe pump). Peribulbar eye blocks were performed using 2% lidocain or a mixture of 2% Lidocain/Marcain (monitored ocular motility was less than 40 microns in retinal space). Primary and secondary damage effects were induced with either q-switched single pulse Neodymium (1064 nm, 1.0 mJ) or Argon CW (10 to 1000 msec, 10-150 mW). MFERG demonstrated capability to detect primary and secondary induced retinal damage in both 1st and 2nd order kernels. Primary and secondary damage in the central retina was often suppressed in amplitude and with longer latencies relative to the MFERG norm. Preliminary investigations in one NHP with Primary and secondary RNFL damage at 9 to 14 months showed recovery with non-scaled array one frame / M-step sequence but demonstrated significant abnormalities for a two frame/ M-step sequence. Utilization of advanced Veris recording parameters involving spatial and temporal manipulation of the stimulus parameters can improve detection of functional deficits induced by focal laser retinal injury.
Barua, Nabanita; Sitaraman, Chitra; Goel, Sonu; Chakraborti, Chandana; Mukherjee, Sonai; Parashar, Hemandra
2016-01-01
Context: Analysis of diagnostic ability of macular ganglionic cell complex and retinal nerve fiber layer (RNFL) in glaucoma. Aim: To correlate functional and structural parameters and comparing predictive value of each of the structural parameters using Fourier-domain (FD) optical coherence tomography (OCT) among primary open angle glaucoma (POAG) and ocular hypertension (OHT) versus normal population. Setting and Design: Single centric, cross-sectional study done in 234 eyes. Materials and Methods: Patients were enrolled in three groups: POAG, ocular hypertensive and normal (40 patients in each group). After comprehensive ophthalmological examination, patients underwent standard automated perimetry and FD-OCT scan in optic nerve head and ganglion cell mode. The relationship was assessed by correlating ganglion cell complex (GCC) parameters with mean deviation. Results were compared with RNFL parameters. Statistical Analysis: Data were analyzed with SPSS, analysis of variance, t-test, Pearson's coefficient, and receiver operating curve. Results: All parameters showed strong correlation with visual field (P < 0.001). Inferior GCC had highest area under curve (AUC) for detecting glaucoma (0.827) in POAG from normal population. However, the difference was not statistically significant (P > 0.5) when compared with other parameters. None of the parameters showed significant diagnostic capability to detect OHT from normal population. In diagnosing early glaucoma from OHT and normal population, only inferior GCC had statistically significant AUC value (0.715). Conclusion: In this study, GCC and RNFL parameters showed equal predictive capability in perimetric versus normal group. In early stage, inferior GCC was the best parameter. In OHT population, single day cross-sectional imaging was not valuable. PMID:27221682
Water resources of Lincoln and Union counties, South Dakota
Niehus, C.A.
1994-01-01
Water resources of Lincoln and Union Counties occur as surface water in streams and lakes and ground water in ten major glacial and one major bedrock aquifers. The major surface-water sources are the Missouri and Big Sioux Rivers. Glacial aquifers contain about 4 million acre-feet of water in storage; 1.5 million acre-feet are contained in the Missouri aquifer. The Wall Lake, Shindler, and Upper Vemillion-Missouri aquifers are deeply buried, confined aquifers with average thicknesses ranging from 31 to 41 feet. The Harrisburg and Big Sioux aquifers are shallow, water-table aquifers with average thicknesses of 26 and 28 feet, respectively. The Parker-Centerville, Newton Hills, and Brule Creek aquifers are buried, confined aquifers with average thicknesses ranging from 33 to 36 feet. The Lower Vermillion-Missouri aquifer is a buried, confined aquifer with an average thickness of 99 feet. The Missouri aquifer is confined in the northeastern portion of the aquifer and is a shallow, water-table aquifer elsewhere with average cumulative thickness of 84 feet.
Gonzalez Caldito, Natalia; Antony, Bhavna; He, Yufan; Lang, Andrew; Nguyen, James; Rothman, Alissa; Ogbuokiri, Esther; Avornu, Ama; Balcer, Laura; Frohman, Elliot; Frohman, Teresa C; Bhargava, Pavan; Prince, Jerry; Calabresi, Peter A; Saidha, Shiv
2018-03-01
Optical coherence tomography (OCT) is a reliable method used to quantify discrete layers of the retina. Spectralis OCT is a device used for this purpose. Spectralis OCT macular scan imaging acquisition can be obtained on either the horizontal or vertical plane. The vertical protocol has been proposed as favorable, due to postulated reduction in confound of Henle's fibers on segmentation-derived metrics. Yet, agreement of the segmentation measures of horizontal and vertical macular scans remains unexplored. Our aim was to determine this agreement. Horizontal and vertical macular scans on Spectralis OCT were acquired in 20 healthy controls (HCs) and 20 multiple sclerosis (MS) patients. All scans were segmented using Heidelberg software and a Johns Hopkins University (JHU)-developed method. Agreement was analyzed using Bland-Altman analyses and intra-class correlation coefficients (ICCs). Using both segmentation techniques, mean differences (agreement at the cohort level) in the thicknesses of all macular layers derived from both acquisition protocols in MS patients and HCs were narrow (<1 µm), while the limits of agreement (LOA) (agreement at the individual level) were wider. Using JHU segmentation mean differences (and LOA) for the macular retinal nerve fiber layer (RNFL) and ganglion cell layer + inner plexiform layer (GCIP) in MS were 0.21 µm (-1.57-1.99 µm) and -0.36 µm (-1.44-1.37 µm), respectively. OCT segmentation measures of discrete retinal-layer thicknesses derived from both vertical and horizontal protocols on Spectralis OCT agree excellently at the cohort level (narrow mean differences), but only moderately at the individual level (wide LOA). This suggests patients scanned using either protocol should continue to be scanned with the same protocol. However, due to excellent agreement at the cohort level, measures derived from both acquisitions can be pooled for outcome purposes in clinical trials.
[A clinical study of Leber hereditary optic neuropathy].
Wei, Qi-Ping; Sun, Yan-Hong; Zhou, Xiang-tian; Zhou, Jian; Gong, Xiao-hong; Jia, Xiao-yun
2012-12-01
To investigate the clinical characteristics of Leber hereditary optic neurology (LHON) patients with different primary site mutation. Four hundred and fourteen patients with optic neuropathy were divided into three groups: clinically diagnosed LHON group (group A), probable LHON group (group B), optic neuropathy of unknown reason group (group C). Visual acuity (VA), colour vision, Intraocular pressure (IOP), virtual field and visual evoked potential (VEP) were tested for all the patients. Some (64 cases) had optical coherence tomography (OCT) measurement. Mutations of mtDNA were detected for all the groups, and clinical analysis were carried out emphatically in the patients with the 11778 mutation confirmed by gene assessment. T paired test was used to evaluate two group patients of different Mitochondrial DNA mutation. Gene mutations were found in 215 of the 414 patients (52%). Approximately 93% (199/255) of the patients were caused by the common primary mutations (11778, 14484, 3460 mutation), in which 100% mutation (106/106) in group A, 65% (91/139) in group B, and 11% (18/169) in group C. No cases were diagnosed with confirmed LHON in the patients with unilateral optic neuropathy. Fundus examination in 334 eyes of 167 cases showed pseudo papilledema (54 eyes), normal (67 eyes), pale disc or pale on the temporal side of the optic disc (213 eyes). On the basis data of OCT from 64 patients and 84 normal person, RNFL was found thickening at the early stage and thinning gradually at the later stage in the LHON patients. But, the RNFL thickness of patients with 1-2 years history was not significantly different from the patients with over 2 years history(P = 0.051), and there was no difference among the patients with different mitochondrial DNA mutations. The initial mean VA of patients with the 14484 mutation and 11778 mutation were 3.6 ± 0.65, 3.75 ± 0.54 (t = 0.536, P > 0.05), but the follow-up VA were 4.29 ± 0.55 (t = 4.034, P < 0.001) and 3.93 ± 0.49 respectively (t = 1.857, P > 0.05). The symptoms and fundus manifestation were similar in the LHOH patients with different primary site mutation. Gene mutation analysis is helpful to assess the prognosis of visual acuity.
The effect of embryonic development on the thickness of the eggshells of the coturnix quail
Kreitzer, J.F.
1972-01-01
The average thickness of the shells from 75 unincubated coturnix quail eggs was found to be 0.193 mm. This was 7.3 percent greater than the average thickness (0.179 mm.) of the shells from 60 fully incubated eggs from the same hens. The two sets of eggs were collected simultaneously. This thickness difference was statistically significant (t-test:p< 0.005).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi Linxi; Vedantham, Srinivasan; Karellas, Andrew
Purpose: To determine the mean and range of location-averaged breast skin thickness using high-resolution dedicated breast CT for use in Monte Carlo-based estimation of normalized glandular dose coefficients. Methods: This study retrospectively analyzed image data from a clinical study investigating dedicated breast CT. An algorithm similar to that described by Huang et al.['The effect of skin thickness determined using breast CT on mammographic dosimetry,' Med. Phys. 35(4), 1199-1206 (2008)] was used to determine the skin thickness in 137 dedicated breast CT volumes from 136 women. The location-averaged mean breast skin thickness for each breast was estimated and the study populationmore » mean and range were determined. Pathology results were available for 132 women, and were used to investigate if the distribution of location-averaged mean breast skin thickness varied with pathology. The effect of surface fitting to account for breast curvature was also studied. Results: The study mean ({+-} interbreast SD) for breast skin thickness was 1.44 {+-} 0.25 mm (range: 0.87-2.34 mm), which was in excellent agreement with Huang et al. Based on pathology, pair-wise statistical analysis (Mann-Whitney test) indicated that at the 0.05 significance level, there were no significant difference in the location-averaged mean breast skin thickness distributions between the groups: benign vs malignant (p= 0.223), benign vs hyperplasia (p= 0.651), hyperplasia vs malignant (p= 0.229), and malignant vs nonmalignant (p= 0.172). Conclusions: Considering this study used a different clinical prototype system, and the study participants were from a different geographical location, the observed agreement between the two studies suggests that the choice of 1.45 mm thick skin layer comprising the epidermis and the dermis for breast dosimetry is appropriate. While some benign and malignant conditions could cause skin thickening, in this study cohort the location-averaged mean breast skin thickness distributions did not differ significantly with pathology. The study also underscored the importance of considering breast curvature in estimating breast skin thickness.« less
Uncertainty in coal property valuation in West Virginia: A case study
Hohn, M.E.; McDowell, R.R.
2001-01-01
Interpolated grids of coal bed thickness are being considered for use in a proposed method for taxation of coal in the state of West Virginia (United States). To assess the origin and magnitude of possible inaccuracies in calculated coal tonnage, we used conditional simulation to generate equiprobable realizations of net coal thickness for two coals on a 7 1/2 min topographic quadrangle, and a third coal in a second quadrangle. Coals differed in average thickness and proportion of original coal that had been removed by erosion; all three coals crop out in the study area. Coal tonnage was calculated for each realization and for each interpolated grid for actual and artificial property parcels, and differences were summarized as graphs of percent difference between tonnage calculated from the grid and average tonnage from simulations. Coal in individual parcels was considered minable for valuation purposes if average thickness in each parcel exceeded 30 inches. Results of this study show that over 75% of the parcels are classified correctly as minable or unminable based on interpolation grids of coal bed thickness. Although between 80 and 90% of the tonnages differ by less than 20% between interpolated values and simulated values, a nonlinear conditional bias might exist in estimation of coal tonnage from interpolated thickness, such that tonnage is underestimated where coal is thin, and overestimated where coal is thick. The largest percent differences occur for parcels that are small in area, although because of the small quantities of coal in question, bias is small on an absolute scale for these parcels. For a given parcel size, maximum apparent overestimation of coal tonnage occurs in parcels with an average coal bed thickness near the minable cutoff of 30 in. Conditional bias in tonnage for parcels having a coal thickness exceeding the cutoff by 10 in. or more is constant for two of the three coals studied, and increases slightly with average thickness for the third coal. ?? 2001 International Association for Mathematical Geology.
March, Rod S.
2000-01-01
The 1995 measured winter snow, maximum winter snow, net, and annual balances in the Gulkana Glacier basin were evaluated on the basis of meteorological, hydrological, and glaciological data obtained in the basin. Averaged over the glacier, the measured winter snow balance was 0.94 meter on April 19, 1995, 0.6 standard deviation below the long-term average; the maximum winter snow balance, 0.94 meter, was reached on April 25, 1995; the net balance (from September 18, 1994 to August 29, 1995) was -0.70 meter, 0.76 standard deviation below the long-term average. The annual balance (October 1, 1994, to September 30, 1995) was -0.86 meter. Ice-surface motion and altitude changes measured at three index sites document seasonal ice speed and glacier-thickness changes. Annual stream runoff was 2.05 meters averaged over the basin, approximately equal to the long-term average. The 1976 ice-thickness data are reported from a single site near the highest measurement site (180 meters thick) and from two glacier cross profiles near the mid-glacier (270 meters thick on centerline) and low glacier (150 meters thick on centerline) measurement sites. A new area-altitude distribution determined from 1993 photogrammetry is reported. Area-averaged balances are reported from both the 1967 and 1993 area-altitude distribution so the reader may directly see the effect of the update. Briefly, loss of ablation area between 1967 and 1993 results in a larger weighting being applied to data from the upper glacier site and hence, increases calculated area-averaged balances. The balance increase is of the order of 15 percent for net balance.
Mediterranean diet, micronutrients and macronutrients, and MRI measures of cortical thickness.
Staubo, Sara C; Aakre, Jeremiah A; Vemuri, Prashanthi; Syrjanen, Jeremy A; Mielke, Michelle M; Geda, Yonas E; Kremers, Walter K; Machulda, Mary M; Knopman, David S; Petersen, Ronald C; Jack, Clifford R; Roberts, Rosebud O
2017-02-01
The Mediterranean diet (MeDi) is associated with reduced risk of cognitive impairment, but it is unclear whether it is associated with better brain imaging biomarkers. Among 672 cognitively normal participants (mean age, 79.8 years, 52.5% men), we investigated associations of MeDi score and MeDi components with magnetic resonance imaging measures of cortical thickness for the four lobes separately and averaged (average lobar). Higher MeDi score was associated with larger frontal, parietal, occipital, and average lobar cortical thickness. Higher legume and fish intakes were associated with larger cortical thickness: legumes with larger superior parietal, inferior parietal, precuneus, parietal, occipital, lingual, and fish with larger precuneus, superior parietal, posterior cingulate, parietal, and inferior parietal. Higher carbohydrate and sugar intakes were associated with lower entorhinal cortical thickness. In this sample of elderly persons, higher adherence to MeDi was associated with larger cortical thickness. These cross-sectional findings require validation in prospective studies. Copyright © 2016 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.
The Distribution of Macular Thickness and Its Determinants in a Healthy Population.
Hashemi, Hassan; Khabazkhoob, Mehdi; Yekta, AbbasAli; Emamian, Mohammad Hassan; Nabovati, Payam; Fotouhi, Akbar
2017-10-01
To determine the distribution of macular thickness in a healthy Iranian population aged 45-69 years and its association with certain determinants. All participants underwent optometric examinations including measurement of uncorrected and corrected visual acuity, objective refraction by retinoscopy, and subjective refraction. Subsequently, all participants underwent slit-lamp biomicroscopy followed by fundus examination through direct and indirect ophthalmoscopy, and optical coherence tomography (OCT) imaging under pupil dilation. Mean central macular thickness was 255.4 µm (95% confidence interval, CI, 254.5-256.3 µm), average inner macular thickness was 316.5 µm (95% CI 315.9-317.1 µm), average outer macular thickness was 275.3 µm (95% CI 274.8-275.8 µm), and overall average thickness was 278.6 µm (95% CI 278.1-279.1 µm). A linear multiple regression model showed that all indexes were significantly larger in male participants (p < 0.001). Central macular thickness increased with age (coef = 0.25, p < 0.001) while overall, inner and outer macular thickness decreased with age (coef = -0.18, -0.15, -0.19, respectively, all p < 0.001). Central and inner macular thickness had a positive correlation (coef = 3.8, 2.6, respectively, both p < 0.001) and outer macular thickness had a negative correlation (coef = -1.6, p < 0.001) with axial length. Age, sex, refractive error, axial length, and keratometry were found to be associated with macular thickness. These factors should be taken into account when interpreting macular thickness measurements with spectral-domain OCT.
Beyond the Map: Enamel Distribution Characterized from 3D Dental Topography
Thiery, Ghislain; Lazzari, Vincent; Ramdarshan, Anusha; Guy, Franck
2017-01-01
Enamel thickness is highly susceptible to natural selection because thick enamel may prevent tooth failure. Consequently, it has been suggested that primates consuming stress-limited food on a regular basis would have thick-enameled molars in comparison to primates consuming soft food. Furthermore, the spatial distribution of enamel over a single tooth crown is not homogeneous, and thick enamel is expected to be more unevenly distributed in durophagous primates. Still, a proper methodology to quantitatively characterize enamel 3D distribution and test this hypothesis is yet to be developed. Unworn to slightly worn upper second molars belonging to 32 species of anthropoid primates and corresponding to a wide range of diets were digitized using high resolution microcomputed tomography. In addition, their durophagous ability was scored from existing literature. 3D average and relative enamel thickness were computed based on the volumetric reconstruction of the enamel cap. Geometric estimates of their average and relative enamel-dentine distance were also computed using 3D dental topography. Both methods gave different estimations of average and relative enamel thickness. This study also introduces pachymetric profiles, a method inspired from traditional topography to graphically characterize thick enamel distribution. Pachymetric profiles and topographic maps of enamel-dentine distance are combined to assess the evenness of thick enamel distribution. Both pachymetric profiles and topographic maps indicate that thick enamel is not significantly more unevenly distributed in durophagous species, except in Cercopithecidae. In this family, durophagous species such as mangabeys are characterized by an uneven thick enamel and high pachymetric profile slopes at the average enamel thickness, whereas non-durophagous species such as colobine monkeys are not. These results indicate that the distribution of thick enamel follows different patterns across anthropoids. Primates might have developed different durophagous strategies to answer the selective pressure exerted by stress-limited food. PMID:28785226
Choi, Stacey S; Zawadzki, Robert J; Greiner, Mark A; Werner, John S; Keltner, John L
2008-06-01
New technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic disc drusen. Using Stratus and Fourier domain (FD) optical coherence tomography (OCT) and adaptive optics (AO) through a flood-illuminated fundus camera, we studied the retinas of a patient with long-standing optic disc drusen and acute visual loss at high altitude attributed to ischemic optic neuropathy. Stratus OCT and FD-OCT confirmed severe thinning of the retinal nerve fiber layer (RNFL). FD-OCT revealed disturbances in the photoreceptor layer heretofore not described in optic disc drusen patients. AO confirmed the FD-OCT findings in the photoreceptor layer and also showed reduced cone density at retinal locations associated with reduced visual sensitivity. Based on this study, changes occur not only in the RNFL but also in the photoreceptor layer in optic nerve drusen complicated by ischemic optic neuropathy. This is the first reported application of FD-OCT and the AO to this condition. Such new imaging technology may in the future allow monitoring of disease progression more precisely and accurately.
NASA Technical Reports Server (NTRS)
Otto, Christian; Ploutz-Snyder, R.
2015-01-01
The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti-lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post-flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio- each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured
NASA Astrophysics Data System (ADS)
Farner, Michael J.; Lee, Cin-Ty A.
2017-07-01
The majority of arc magmas are highly evolved due to differentiation within the lithosphere or crust. Some studies have suggested a relationship between crustal thickness and magmatic differentiation, but the exact nature of this relationship is unclear. Here, we examine the interplay of crustal thickness and magmatic differentiation using a global geochemical dataset compiled from active volcanic arcs and elevation as a proxy for crustal thickness. With increasing crustal thickness, average arc magma compositions become more silicic (andesitic) and enriched in incompatible elements, indicating that on average, arc magmas in thick crust are more evolved, which can be easily explained by the longer transit and cooling times of magmas traversing thick arc lithosphere and crust. As crustal thickness increases, arc magmas show higher degrees of iron depletion at a given MgO content, indicating that arc magmas saturate earlier in magnetite when traversing thick crust. This suggests that differentiation within thick crust occurs under more oxidizing conditions and that the origin of oxidation is due to intracrustal processes (contamination or recharge) or the role of thick crust in modulating melting degree in the mantle wedge. We also show that although arc magmas are on average more silicic in thick crust, the most silicic magmas (>70 wt.% SiO2) are paradoxically found in thin crust settings, where average compositions are low in silica (basaltic). We suggest that extreme residual magmas, such as those exceeding 70 wt.% SiO2, are preferentially extracted from shallow crustal magma bodies than from deep-seated magma bodies, the latter more commonly found in regions of thick crust. We suggest that this may be because the convective lifespan of crustal magma bodies is limited by conductive cooling through the overlying crustal lid and that magma bodies in thick crust cool more slowly than in thin crust. When the crust is thin, cooling is rapid, preventing residual magmas from being extracted; in the rare case that residual magmas can be extracted, they represent the very last melt fractions, which are highly silicic. When the crust is thick, cooling is slow, so intermediate melt fractions can readily segregate and erupt to the surface, where they cool and crystallize before highly silicic residual melts can be generated.
Davis, Robert E.; Christenson, Scott C.
1981-01-01
A quantitative description of the hydrologic system in alluvium and terrace deposits along the Beaver-North Canadian River in northwestern Oklahoma is needed as an aid for planning and management of the aquifer. A two-dimensional finite-difference model was used to describe the aquifer and to predict the effects of future ground-water withdrawals.The aquifer principally consists of three geologic units: Alluvium with an average thickness of 30 feet, low terrace deposits with an average thickness of 50 feet, and high terrace deposits with an average thickness of 70 feet. A thin cover of dune sand overlies much of the area and provides an excellent catchment for recharge, but is generally unsaturated.Hydraulic conductivity of the aquifer ranges from 0 to 160 feet per day and averages 59 feet per day. Specific yield is estimated to be 0.29. Recharge to the aquifer is approximately 1 inch annually. Under present conditions (1978), most discharge is the result of ground-water flow to the Beaver-North Canadian River at a rate of 36 cubic feet per second and to pumpage for public-supply, industrial, and irrigation use at a rate of 28 cubic feet per second. In 1978, the aquifer had an average saturated thickness of 31 feet and contained 4.07 million acre-feet of water.The model was used to predict future head response in the aquifer to various pumping stresses. For any one area, the pumping stress was applied until the saturated thickness for that area was less than 5 feet, at which time the pumping ceased.The results of the modeled projections show that if the aquifer is stressed from 1978 to 1993 at the 1977 pumpage rates and well distribution, the average saturated thickness will decrease 1.0 foot and the volume of water in storage will be 3.94 million acre-feet, or 97 percent of the 1978 volume. If the aquifer is stressed at this same rate until 2020, the average saturated thickness will decrease an additional 0.7 foot and the volume of water in storage will be 3.84 million acre-feet, or 94 percent of the 1978 volume.If all areas of the aquifer having a 1978 saturated thickness of 5 feet or more are stressed from 1978 to 1993 at a rate of approximately1.4 acre-feet per acre per year, the average saturated thickness will decrease by 20.9 feet and the volume of water in storage will be 1.28 million acre-feet, or 31 percent of the 1978 volume. If the aquifer is stressed at this same rate until 2020, the average saturated thickness will decrease an additional 2.2 feet and the volume of water in storage will be 980,000 acre-feet, or 24 percent of the 1978 volume.The water in the aquifer is generally of the calcium bicarbonate type and is suitable for most uses. Most of the 30 water samples analyzed contained less than 500 milligrams of dissolved solids per liter.
Ductility of polystyrene waste panel
NASA Astrophysics Data System (ADS)
Sulistyorini, Dewi; Yasin, Iskandar
2018-03-01
Polystyrene waste panel is one of alternative materials that uses polystyrene waste. This experiment is to utilize the polystyrene waste as a non structural panel to be evaluated the ductility. The specimen consisted of cement 250 kg/m3, polystyrene waste was as aggregate, water cement ratio was 0.4 and wire mesh diameter was 0.6 mm with the grid 6 mm × 6 mm placed on the top and bottom of the panels. The polystyrene panels were compressed at 2 MPa. Six specimens had dimension 80 cm length, 30 cm width and the thickness planned were two varieties, they were 0.5 cm and 1 cm. Flexural testing is used to examine load and deflection to measure the ductility. The load and the deflection showed that the maximum load for the specimen with 0.5 cm thickness is 0.4, 0.56 and 0.37. And for 1 cm thickness is 0.4, 0.36, 0.64. It shows that the thickness variation does not give effect on the maximum load. Result showed the average of Displacement Ductility Index of polystyrene waste panels with 0.5 cm thickness was 1.692 and for 1 cm thickness, the average was 4.043. So the average of the panel with 0.5 cm thickness planned is under 1.99 and the panel with 1 cm thickness planned is upper 3, therefore, it is considered imperative for adequate ductility.
Imperfection sensitivity of pressured buckling of biopolymer spherical shells
NASA Astrophysics Data System (ADS)
Zhang, Lei; Ru, C. Q.
2016-06-01
Imperfection sensitivity is essential for mechanical behavior of biopolymer shells [such as ultrasound contrast agents (UCAs) and spherical viruses] characterized by high geometric heterogeneity. In this work, an imperfection sensitivity analysis is conducted based on a refined shell model recently developed for spherical biopolymer shells of high structural heterogeneity and thickness nonuniformity. The influence of related parameters (including the ratio of radius to average shell thickness, the ratio of transverse shear modulus to in-plane shear modulus, and the ratio of effective bending thickness to average shell thickness) on imperfection sensitivity is examined for pressured buckling. Our results show that the ratio of effective bending thickness to average shell thickness has a major effect on the imperfection sensitivity, while the effect of the ratio of transverse shear modulus to in-plane shear modulus is usually negligible. For example, with physically realistic parameters for typical imperfect spherical biopolymer shells, the present model predicts that actual maximum external pressure could be reduced to as low as 60% of that of a perfect UCA spherical shell or 55%-65% of that of a perfect spherical virus shell, respectively. The moderate imperfection sensitivity of spherical biopolymer shells with physically realistic imperfection is largely attributed to the fact that biopolymer shells are relatively thicker (defined by smaller radius-to-thickness ratio) and therefore practically realistic imperfection amplitude normalized by thickness is very small as compared to that of classical elastic thin shells which have much larger radius-to-thickness ratio.
Thick Prelaminar Tissue Decreases Lamina Cribrosa Visibility.
Lucy, Katie A; Wang, Bo; Schuman, Joel S; Bilonick, Richard A; Ling, Yun; Kagemann, Larry; Sigal, Ian A; Grulkowski, Ireneusz; Liu, Jonathan J; Fujimoto, James G; Ishikawa, Hiroshi; Wollstein, Gadi
2017-03-01
Evaluation of the effect of prelaminar tissue thickness on visualization of the lamina cribrosa (LC) using optical coherence tomography (OCT). The optic nerve head (ONH) region was scanned using OCT. The quality of visible LC microstructure was assessed subjectively using a grading system and objectively by analyzing the signal intensity of each scan's superpixel components. Manual delineations were made separately and in 3-dimensions quantifying prelaminar tissue thickness, analyzable regions of LC microstructure, and regions with a visible anterior LC (ALC) boundary. A linear mixed effect model quantified the association between tissue thickness and LC visualization. A total of 17 healthy, 27 glaucoma suspect, and 47 glaucomatous eyes were included. Scans with thicker average prelaminar tissue measurements received worse grading scores (P = 0.007), and superpixels with low signal intensity were associated significantly with regions beneath thick prelaminar tissue (P < 0.05). The average prelaminar tissue thickness in regions of scans where the LC was analyzable (214 μm) was significantly thinner than in regions where the LC was not analyzable (569 μm; P < 0.001). Healthy eyes had significantly thicker average prelaminar tissue measurements than glaucoma or glaucoma suspect eyes (both P < 0.001), and glaucoma suspect eyes had significantly thicker average prelaminar tissue measurements than glaucoma eyes (P = 0.008). Significantly more of the ALC boundary was visible in glaucoma eyes (63% of ONH) than in healthy eyes (41%; P = 0.005). Thick prelaminar tissue was associated with impaired visualization of the LC. Healthy subjects generally had thicker prelaminar tissue, which potentially could create a selection bias against healthy eyes when comparing LC structures.
Optical properties of hybrid quantum-well–dots nanostructures grown by MOCVD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mintairov, S. A., E-mail: mintairov@scell.ioffe.ru; Kalyuzhnyy, N. A.; Nadtochiy, A. M.
The deposition of In{sub x}Ga{sub 1–x}As with an indium content of 0.3–0.5 and an average thickness of 3–27 single layers on a GaAs wafer by metalorganic chemical vapor deposition (MOCVD) at low temperatures results in the appearance of thickness and composition modulations in the layers being formed. Such structures can be considered to be intermediate nanostructures between ideal quantum wells and quantum dots. Depending on the average thickness and composition of the layers, the wavelength of the photoluminescence peak for the hybrid InGaAs quantum well–dots nanostructures varies from 950 to 1100 nm. The optimal average In{sub x}Ga{sub 1–x}As thicknesses andmore » compositions at which the emission wavelength is the longest with a high quantum efficiency retained are determined.« less
Intelligence and cortical thickness in children with complex partial seizures.
Tosun, Duygu; Caplan, Rochelle; Siddarth, Prabha; Seidenberg, Michael; Gurbani, Suresh; Toga, Arthur W; Hermann, Bruce
2011-07-15
Prior studies on healthy children have demonstrated regional variations and a complex and dynamic relationship between intelligence and cerebral tissue. Yet, there is little information regarding the neuroanatomical correlates of general intelligence in children with epilepsy compared to healthy controls. In vivo imaging techniques, combined with methods for advanced image processing and analysis, offer the potential to examine quantitative mapping of brain development and its abnormalities in childhood epilepsy. A surface-based, computational high resolution 3-D magnetic resonance image analytic technique was used to compare the relationship of cortical thickness with age and intelligence quotient (IQ) in 65 children and adolescents with complex partial seizures (CPS) and 58 healthy controls, aged 6-18 years. Children were grouped according to health status (epilepsy; controls) and IQ level (average and above; below average) and compared on age-related patterns of cortical thickness. Our cross-sectional findings suggest that disruption in normal age-related cortical thickness expression is associated with intelligence in pediatric CPS patients both with average and below average IQ scores. Copyright © 2011 Elsevier Inc. All rights reserved.
7 CFR 51.776 - Slightly rough texture.
Code of Federal Regulations, 2011 CFR
2011-01-01
... texture. Slightly rough texture means that the skin may be slightly thick but not excessively thick, materially ridged or grooved. “Slightly thick” means that the skin thickness does not average more than 5/8...
7 CFR 51.776 - Slightly rough texture.
Code of Federal Regulations, 2012 CFR
2012-01-01
... texture. Slightly rough texture means that the skin may be slightly thick but not excessively thick, materially ridged or grooved. “Slightly thick” means that the skin thickness does not average more than 5/8...
7 CFR 51.776 - Slightly rough texture.
Code of Federal Regulations, 2010 CFR
2010-01-01
... texture. Slightly rough texture means that the skin may be slightly thick but not excessively thick, materially ridged or grooved. “Slightly thick” means that the skin thickness does not average more than 5/8...
[Glaucoma and optic nerve drusen: Limitations of optic nerve head OCT].
Poli, M; Colange, J; Goutagny, B; Sellem, E
2017-09-01
Optic nerve head drusen are congenital calcium deposits located in the prelaminar section of the optic nerve head. Their association with visual field defects has been classically described, but the diagnosis of glaucoma is not easy in these cases of altered optic nerve head anatomy. We describe the case of a 67-year-old man with optic nerve head drusen complicated by glaucoma, which was confirmed by visual field and OCT examination of the peripapillary retinal nerve fiber layer (RNFL), but the measurement of the minimum distance between the Bruch membrane opening and the internal limiting membrane (minimum rim width, BMO-MRW) by OCT was normal. OCT of the BMO-MRW is a new diagnostic tool for glaucoma. Superficial optic nerve head drusen, which are found between the internal limiting membrane and the Bruch's membrane opening, overestimate the value of this parameter. BMO-MRW measurement is not adapted to cases of optic nerve head drusen and can cause false-negative results for this parameter, and the diagnosis of glaucoma in this case should be based on other parameters such as the presence of a fascicular defect in the retinal nerve fibers, RNFL or macular ganglion cell complex thinning, as well as visual field data. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
[A rare cause of optic neuropathy: Cassava].
Zeboulon, P; Vignal-Clermont, C; Baudouin, C; Labbé, A
2016-06-01
Cassava root is a staple food for almost 500 million people worldwide. Excessive consumption of it is a rare cause of optic neuropathy. Ten patients diagnosed with cassava root related optic neuropathy were included in this retrospective study. Diagnostic criteria were a bilateral optic neuropathy preceded by significant cassava root consumption. Differential diagnoses were excluded through a neuro-ophthalmic examination, blood tests and a brain MRI. All patients had visual field examination and OCT retinal nerve fiber layer (RNFL) analysis as well as an evaluation of their cassava consumption. All patients had a bilateral optic nerve head atrophy or pallor predominantly located into the temporal sector. Visual field defects consisted of a central or cecocentral scotoma for all patients. RNFL showed lower values only in the temporal sector. Mean duration of cassava consumption prior to the appearance of visual symptoms was 22.7±11.2 years with a mean of 2.57±0.53 cassava-based meals per week. Cassava related optic neuropathy is possibly due to its high cyanide content and enabled by a specific amino-acid deficiency. Cassava root chronic consumption is a rare, underappreciated cause of optic neuropathy and its exact mechanism is still uncertain. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Thick Prelaminar Tissue Decreases Lamina Cribrosa Visibility
Lucy, Katie A.; Wang, Bo; Schuman, Joel S.; Bilonick, Richard A.; Ling, Yun; Kagemann, Larry; Sigal, Ian A.; Grulkowski, Ireneusz; Liu, Jonathan J.; Fujimoto, James G.; Ishikawa, Hiroshi; Wollstein, Gadi
2017-01-01
Purpose Evaluation of the effect of prelaminar tissue thickness on visualization of the lamina cribrosa (LC) using optical coherence tomography (OCT). Methods The optic nerve head (ONH) region was scanned using OCT. The quality of visible LC microstructure was assessed subjectively using a grading system and objectively by analyzing the signal intensity of each scan's superpixel components. Manual delineations were made separately and in 3-dimensions quantifying prelaminar tissue thickness, analyzable regions of LC microstructure, and regions with a visible anterior LC (ALC) boundary. A linear mixed effect model quantified the association between tissue thickness and LC visualization. Results A total of 17 healthy, 27 glaucoma suspect, and 47 glaucomatous eyes were included. Scans with thicker average prelaminar tissue measurements received worse grading scores (P = 0.007), and superpixels with low signal intensity were associated significantly with regions beneath thick prelaminar tissue (P < 0.05). The average prelaminar tissue thickness in regions of scans where the LC was analyzable (214 μm) was significantly thinner than in regions where the LC was not analyzable (569 μm; P < 0.001). Healthy eyes had significantly thicker average prelaminar tissue measurements than glaucoma or glaucoma suspect eyes (both P < 0.001), and glaucoma suspect eyes had significantly thicker average prelaminar tissue measurements than glaucoma eyes (P = 0.008). Significantly more of the ALC boundary was visible in glaucoma eyes (63% of ONH) than in healthy eyes (41%; P = 0.005). Conclusions Thick prelaminar tissue was associated with impaired visualization of the LC. Healthy subjects generally had thicker prelaminar tissue, which potentially could create a selection bias against healthy eyes when comparing LC structures. PMID:28324116
Kanellopoulos, Anastasios John; Aslanides, Ioannis M; Asimellis, George
2012-01-01
To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). Epithelial pachymetry measurements (topographic mapping) were conducted on 100 subjects via HF UBM. Three groups of patients were included: patients with normal eyes (controls), patients with untreated keratoconic eyes, and patients with keratoconic eyes treated with CXL. Central, mean, and peripheral corneal epithelial thickness was examined for each group, and a statistical study was conducted. Mean, central, and peripheral corneal epithelial thickness was compared between the three groups of patients. Epithelium thickness varied substantially in the keratoconic group, and in some cases there was a difference of up to 20 μm between various points of the same eye, and often a thinner epithelium coincided with a thinner cornea. However, on average, data from the keratoconic group suggested an overall thickening of the epithelium, particularly over the pupil center of the order of +3 μm, while the mean epithelium thickness was on average +1.1 μm, compared to the control population (P = 0.005). This overall thickening was more pronounced in younger patients in the keratoconic group. Keratoconic eyes previously treated with CXL showed, on average, virtually the same average epithelium thickness (mean -0.7 μm, -0.2 μm over the pupil center, -0.9 μm over the peripheral zone) as the control group. This finding further reinforces our novel theory of the "reactive" component of epithelial thickening in corneas that are biomechanically unstable, becoming stable when biomechanical rigidity is accomplished despite persistence of cornea topographic irregularity. A highly irregular epithelium may be suggestive of an ectatic cornea. Our results indicate that the epithelium is thinner over the keratoconic protrusion, but to a much lesser extent than anticipated, and on average epithelium is thicker in this group of patients. This difference appears to be clinically significant and may become a screening tool for eyes suspected for ectasia.
Kanellopoulos, Anastasios John; Aslanides, Ioannis M; Asimellis, George
2012-01-01
Purpose To determine and correlate epithelial corneal thickness (pachymetric) measurements taken with a digital arc scanning very high frequency ultrasound biomicroscopy (HF UBM) imaging system (Artemis-II), and compare mean and central epithelial thickness among normal eyes, untreated keratoconic eyes, and keratoconic eyes previously treated with collagen crosslinking (CXL). Methods Epithelial pachymetry measurements (topographic mapping) were conducted on 100 subjects via HF UBM. Three groups of patients were included: patients with normal eyes (controls), patients with untreated keratoconic eyes, and patients with keratoconic eyes treated with CXL. Central, mean, and peripheral corneal epithelial thickness was examined for each group, and a statistical study was conducted. Results Mean, central, and peripheral corneal epithelial thickness was compared between the three groups of patients. Epithelium thickness varied substantially in the keratoconic group, and in some cases there was a difference of up to 20 μm between various points of the same eye, and often a thinner epithelium coincided with a thinner cornea. However, on average, data from the keratoconic group suggested an overall thickening of the epithelium, particularly over the pupil center of the order of +3 μm, while the mean epithelium thickness was on average +1.1 μm, compared to the control population (P = 0.005). This overall thickening was more pronounced in younger patients in the keratoconic group. Keratoconic eyes previously treated with CXL showed, on average, virtually the same average epithelium thickness (mean −0.7 μm, −0.2 μm over the pupil center, −0.9 μm over the peripheral zone) as the control group. This finding further reinforces our novel theory of the “reactive” component of epithelial thickening in corneas that are biomechanically unstable, becoming stable when biomechanical rigidity is accomplished despite persistence of cornea topographic irregularity. Conclusion A highly irregular epithelium may be suggestive of an ectatic cornea. Our results indicate that the epithelium is thinner over the keratoconic protrusion, but to a much lesser extent than anticipated, and on average epithelium is thicker in this group of patients. This difference appears to be clinically significant and may become a screening tool for eyes suspected for ectasia. PMID:22701079
Stratification in the lunar regolith - A preliminary view
NASA Technical Reports Server (NTRS)
Duke, M. B.; Nagle, J. S.
1975-01-01
Although our knowledge of lunar regolith stratification is incomplete, several categories of thick and thin strata have been identified. Relatively thick units average 2 to 3 cm in thickness, and appear surficially to be massive. On more detailed examination, these units can be uniformly fine-grained, can show internal trends, or can show internal variations which apparently are random. Other thick units contain soil clasts apparently reworked from underlying units. Thin laminae average approximately 1 mm in thickness; lenticular distribution and composition of some thin laminae indicates that they are fillets shed from adjacent rock fragments. Other dark fine-grained well-sorted thin laminae appear to be surficial zones reworked by micrometeorites. Interpretations of stratigraphic succession can be strengthened by the occurrence of characteristic coarse rock fragments and the orientation of large spatter agglutinates, which are commonly found in their original depositional orientation.
Ghassibi, Mark P; Chien, Jason L; Patthanathamrongkasem, Thipnapa; Abumasmah, Ramiz K; Rosman, Michael S; Skaat, Alon; Tello, Celso; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul
2017-04-01
To compare varying circumpapillary optical coherence tomographic (OCT) scan diameters for glaucoma diagnosis. Prospective, cross-sectional, observational study. Circumpapillary retinal nerve fiber layer thickness (RNFLT) was measured using spectral-domain OCT in 1 randomly selected eye. Scans with diameters of 3.5, 4.1, and 4.7 mm were obtained, each with 7 parameters: mean global (G) RNFLT and mean RNFLT for the temporal-inferior (TI), nasal-inferior (NI), temporal-superior (TS), nasal-superior (NS), nasal (N), and temporal (T) sectors. Areas under the receiver operating characteristic curve (AUCs) were calculated. Mean age was 55±18 years in 68 healthy eyes and 59±15 years in 95 glaucomatous eyes (P=0.12). Visual field mean deviation was -7.55±6.61 dB in glaucomatous eyes. In all 3 circle scans, mean TI RNFLT had the greatest AUC (0.974 to 0.983), followed by mean G RNFLT (0.949 to 0.956). The AUC of mean TI RNFLT in the 4.1-mm scan (0.983) was greater than the AUCs of mean TI RNFLTs in the 4.7- (0.978; P=0.128) and 3.5-mm (0.974; P=0.049) scans. The AUC of mean TI RNFLT in the 4.1-mm scan (0.983) was greater than the AUCs of mean G RNFLTs in the 3.5- (0.954; P=0.011), 4.1- (0.956; P=0.016), and 4.7-mm (0.949; P=0.011) scans. In 2 eyes with large parapapillary atrophy, RNFL segmentation error was noted only in the 3.5-mm scan in the area of parapapillary atrophy. Further investigations to find the spectral-domain OCT circle scan diameter with the best diagnostic capability and the least artifacts are warranted, especially focusing on larger-than-conventional circle scans.
Automated Segmentability Index for Layer Segmentation of Macular SD-OCT Images.
Lee, Kyungmoo; Buitendijk, Gabriëlle H S; Bogunovic, Hrvoje; Springelkamp, Henriët; Hofman, Albert; Wahle, Andreas; Sonka, Milan; Vingerling, Johannes R; Klaver, Caroline C W; Abràmoff, Michael D
2016-03-01
To automatically identify which spectral-domain optical coherence tomography (SD-OCT) scans will provide reliable automated layer segmentations for more accurate layer thickness analyses in population studies. Six hundred ninety macular SD-OCT image volumes (6.0 × 6.0 × 2.3 mm 3 ) were obtained from one eyes of 690 subjects (74.6 ± 9.7 [mean ± SD] years, 37.8% of males) randomly selected from the population-based Rotterdam Study. The dataset consisted of 420 OCT volumes with successful automated retinal nerve fiber layer (RNFL) segmentations obtained from our previously reported graph-based segmentation method and 270 volumes with failed segmentations. To evaluate the reliability of the layer segmentations, we have developed a new metric, segmentability index SI, which is obtained from a random forest regressor based on 12 features using OCT voxel intensities, edge-based costs, and on-surface costs. The SI was compared with well-known quality indices, quality index (QI), and maximum tissue contrast index (mTCI), using receiver operating characteristic (ROC) analysis. The 95% confidence interval (CI) and the area under the curve (AUC) for the QI are 0.621 to 0.805 with AUC 0.713, for the mTCI 0.673 to 0.838 with AUC 0.756, and for the SI 0.784 to 0.920 with AUC 0.852. The SI AUC is significantly larger than either the QI or mTCI AUC ( P < 0.01). The segmentability index SI is well suited to identify SD-OCT scans for which successful automated intraretinal layer segmentations can be expected. Interpreting the quantification of SD-OCT images requires the underlying segmentation to be reliable, but standard SD-OCT quality metrics do not predict which segmentations are reliable and which are not. The segmentability index SI presented in this study does allow reliable segmentations to be identified, which is important for more accurate layer thickness analyses in research and population studies.
Average chest wall thickness at two anatomic locations in trauma patients.
Schroeder, Elizabeth; Valdez, Carrie; Krauthamer, Andres; Khati, Nadia; Rasmus, Jessica; Amdur, Richard; Brindle, Kathleen; Sarani, Babak
2013-09-01
Needle thoracostomy is the emergent treatment for tension pneumothorax. This procedure is commonly done using a 4.5cm catheter, and the optimal site for chest wall puncture is controversial. We hypothesize that needle thoracostomy cannot be performed using this catheter length irrespective of the site chosen in either gender. A retrospective review of all chest computed tomography (CT) scans obtained on trauma patients from January 1, 2011 to December 31, 2011 was performed. Patients aged 18 and 80 years were included and patients whose chest wall thickness exceeded the boundary of the images acquired were excluded. Chest wall thickness was measured at the 2nd intercostal (ICS), midclavicular line (MCL) and the 5th ICS, anterior axillary line (AAL). Injury severity score (ISS), chest wall thickness, and body mass index (BMI) were analyzed. 201 patients were included, 54% male. Average (SD) BMI was 26 (7)kg/m(2). The average chest wall thickness in the overall cohort was 4.08 (1.4)cm at the 2nd ICS/MCL and 4.55 (1.7)cm at the 5th ICS/AAL. 29% of the overall cohort (27 male and 32 female) had a chest wall thickness greater than 4.5cm at the 2nd ICS/MCL and 45% (54 male and 36 female) had a chest wall thickness greater than 4.5cm at the 5th ICS/AAL. There was no significant interaction between gender and chest wall thickness at either site. BMI was positively associated with chest wall thickness at both the 2nd and 5th ICS/AAL. A 4.5cm catheter is inadequate for needle thoracostomy in most patients regardless of puncture site or gender. Copyright © 2013 Elsevier Ltd. All rights reserved.
Modeling the Thickness of Perennial Ice Covers on Stratified Lakes of the Taylor Valley, Antarctica
NASA Technical Reports Server (NTRS)
Obryk, M. K.; Doran, P. T.; Hicks, J. A.; McKay, C. P.; Priscu, J. C.
2016-01-01
A one-dimensional ice cover model was developed to predict and constrain drivers of long term ice thickness trends in chemically stratified lakes of Taylor Valley, Antarctica. The model is driven by surface radiative heat fluxes and heat fluxes from the underlying water column. The model successfully reproduced 16 years (between 1996 and 2012) of ice thickness changes for west lobe of Lake Bonney (average ice thickness = 3.53 m; RMSE = 0.09 m, n = 118) and Lake Fryxell (average ice thickness = 4.22 m; RMSE = 0.21 m, n = 128). Long-term ice thickness trends require coupling with the thermal structure of the water column. The heat stored within the temperature maximum of lakes exceeding a liquid water column depth of 20 m can either impede or facilitate ice thickness change depending on the predominant climatic trend (temperature cooling or warming). As such, shallow (< 20 m deep water columns) perennially ice-covered lakes without deep temperature maxima are more sensitive indicators of climate change. The long-term ice thickness trends are a result of surface energy flux and heat flux from the deep temperature maximum in the water column, the latter of which results from absorbed solar radiation.
Jiang, Ming-Ming; Zhou, Qing; Liu, Xiao-Yong; Shi, Chang-Zheng; Chen, Jian; Huang, Xiang-He
2017-03-01
To investigate structural and functional brain changes in patients with primary open-angle glaucoma (POAG) by using voxel-based morphometry based on diffeomorphic anatomical registration through exponentiated Lie algebra (VBM-DARTEL) and blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI), respectively.Thirteen patients diagnosed with POAG and 13 age- and sex-matched healthy controls were enrolled in the study. For each participant, high-resolution structural brain imaging and blood flow imaging were acquired on a 3.0-Tesla magnetic resonance imaging (MRI) scanner. Structural and functional changes between the POAG and control groups were analyzed. An analysis was carried out to identify correlations between structural and functional changes acquired in the previous analysis and the retinal nerve fiber layer (RNFL).Patients in the POAG group showed a significant (P < 0.001) volume increase in the midbrain, left brainstem, frontal gyrus, cerebellar vermis, left inferior parietal lobule, caudate nucleus, thalamus, precuneus, and Brodmann areas 7, 18, and 46. Moreover, significant (P < 0.001) BOLD signal changes were observed in the right supramarginal gyrus, frontal gyrus, superior frontal gyrus, left inferior parietal lobule, left cuneus, and left midcingulate area; many of these regions had high correlations with the RNFL.Patients with POAG undergo widespread and complex changes in cortical brain structure and blood flow. (ClinicalTrials.gov number: NCT02570867).
Hood, Donald C.
2017-01-01
Although ophthalmologists are becoming increasingly reliant upon optical coherence tomography (OCT), clinicians who care for glaucoma patients are not taking full advantage of the potential of this powerful technology. First, we ask, how would one describe the nature of glaucomatous damage if only OCT scans were available? In particular, a schematic model of glaucomatous damage is developed in section 2, and the nature of glaucomatous damage seen on OCT scans described in the context of this model in section 3. In particular, we illustrate that local thinning of the circumpapillary retinal nerve fiber layer (cpRNFL) around the optic disc can vary in location, depth, and/or width, as well as homogeneity of damage. Second, we seek to better understand the relationship between the thinning of the cpRNFL and the various patterns of sensitivity loss seen on visual fields obtained with standard automated perimetry. In sections 4 and 5, we illustrate why one should expect a wide range of visual field patterns, and iilustrate why they should not be placed into discrete categories. Finally, section 6 describes how the clinician can take better advantage of the information in OCT scans. The approach is summarized in a single-page report, which can be generated from a single wide-field scan. The superiority of this approach, as opposed to the typical reliance on summary metrics, is described. PMID:28012881
Tagawa, Yoshiaki; Suzuki, Yasuo; Sakaguchi, Takatoshi; Endoh, Hiroki; Yokoi, Masahiko; Kase, Manabu
2014-01-01
A 29-year-old fisherman exhibited optic disc oedema and peripapillary retinal detachment in the right eye, whereas in the left eye, optic atrophy and intraretinal exudates were already observed on first examination. About 6 months earlier, he noticed blurred vision of the left eye but took no medication. Visual acuity was 0.4 OD and 0.01 OS. Perimetry showed a large lower-half field defect with sparing 10° central field in the right eye and a large central scotoma in the left eye. Fluorescein angiography showed existence of arteriole or capillary nonperfusion and hyperpermeability of surrounding capillaries. Since serological examinations showed positive Bartonella immunoglobulin G (IgG) and other causes of neuroretinitis (NR) were excluded, NR in the present case was caused by cat scratch disease (CSD). Optic atrophy appeared 2 weeks after onset. Optical coherence tomography 13 weeks after onset revealed severe loss of retinal nerve fibre layer (RNFL) superior and nasal to the optic disc in both eyes and temporal in the left eye. Visual acuity of the right eye improved to 1.2 by the treatment, whereas visual field defects were persistent. CSD-NR in the present case developed abrupt appearance of optic atrophy with severe RNFL loss in the right eye, which was elicited by exudative, obliterative vasculitis in the superficial layer of the optic disc.
Humrich, Marco; Goepel, Lisa; Gutknecht, Mandy; Lohrberg, David; Blessmann, Marco; Bruning, Guido; Diener, Holger; Dissemond, Joachim; Hartmann, Bernd; Augustin, Matthias
2018-04-01
Split-thickness skin grafting is a common procedure to treat different kinds of wounds. This systematic, multicentre, observational, cross-sectional study of adult patients with split-thickness skin graft (STSG) donor site wounds was conducted to evaluate quality of life (QoL) impairments caused by donor site wounds following split-thickness skin grafting. Therefore, 112 patients from 12 wound centres in Germany were examined based on patient and physician questionnaires as well as a physical examination of the donor site wound. Most indications for skin grafting were postsurgical treatment (n = 51; 42.5%) and chronic wounds (n = 47; 39.2%). European QoL visual analoque scale (EQ VAS) averaged 64.7 ± 23.3, European QoL 5 dimensions (EQ-5D) averaged 77.4 ± 30.0. Wound-QoL (range: 0-4) was rated 0.8 ± 0.8 post-surgery and 0.4 ± 0.6 at the time of survey (on average 21 weeks between the time points). Compared to averaged Wound-QoL scores of chronic wounds donor site-related QoL impairments in split-thickness skin-graft patients were less pronounced. There were significant differences in patient burden immediately after surgery compared to the time of the survey, with medium effect sizes. This supports the hypothesis that faster healing of the donor site wound leads to more favourable patient-reported outcomes. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Accurate Measurement of Small Airways on Low-Dose Thoracic CT Scans in Smokers
Conradi, Susan H.; Atkinson, Jeffrey J.; Zheng, Jie; Schechtman, Kenneth B.; Senior, Robert M.; Gierada, David S.
2013-01-01
Background: Partial volume averaging and tilt relative to the scan plane on transverse images limit the accuracy of airway wall thickness measurements on CT scan, confounding assessment of the relationship between airway remodeling and clinical status in COPD. The purpose of this study was to assess the effect of partial volume averaging and tilt corrections on airway wall thickness measurement accuracy and on relationships between airway wall thickening and clinical status in COPD. Methods: Airway wall thickness measurements in 80 heavy smokers were obtained on transverse images from low-dose CT scan using the open-source program Airway Inspector. Measurements were corrected for partial volume averaging and tilt effects using an attenuation- and geometry-based algorithm and compared with functional status. Results: The algorithm reduced wall thickness measurements of smaller airways to a greater degree than larger airways, increasing the overall range. When restricted to analyses of airways with an inner diameter < 3.0 mm, for a theoretical airway of 2.0 mm inner diameter, the wall thickness decreased from 1.07 ± 0.07 to 0.29 ± 0.10 mm, and the square root of the wall area decreased from 3.34 ± 0.15 to 1.58 ± 0.29 mm, comparable to histologic measurement studies. Corrected measurements had higher correlation with FEV1, differed more between BMI, airflow obstruction, dyspnea, and exercise capacity (BODE) index scores, and explained a greater proportion of FEV1 variability in multivariate models. Conclusions: Correcting for partial volume averaging improves accuracy of airway wall thickness estimation, allowing direct measurement of the small airways to better define their role in COPD. PMID:23172175
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien
Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposuremore » factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average {+-} standard deviation CBT and breast glandularity in this study were 4.2 {+-} 1.0 cm and 54% {+-} 23%, respectively. The average equivalent PMMA thickness was 4.0 {+-} 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.« less
Fallahi Motlagh, Behzad; Sadeghi, Ali
2017-01-01
The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and pattern standard deviation (PSD), were recorded and correlated with spectral domain optical coherence tomography (SD-OCT)-measured macular thickness and asymmetry. Average macular thickness correlated significantly with all measures of visual field including MD-SWAP (r = 0.42), MD-SAP (r = 0.41), PSD-SWAP (r = -0.23), and PSD-SAP (r = -0.21), with P-values <0.001 for all correlations. The mean MD scores (using both SWAP and SAP) were significantly higher in the eyes with thin than in those with intermediate average macular thickness. Intraeye (superior macula thickness - inferior macula thickness) asymmetries correlated significantly with both PSD-SWAP (r = 0.63, P < 0.001) and PSD-SAP (r = 0.26, P = 0.01) scores. This study revealed a significant correlation between macular thickness and visual field parameters in early glaucoma. The results of this study should make macular thickness measurements even more meaningful to glaucoma specialists.
Doughty, Michael J
2017-07-01
The aim was to assess differences in eyeball mass, corneal diameter and central corneal thickness in slaughterhouse-procured ovine eyes. Over a 12-year period, measurements of eye globe mass, horizontal corneal diameter and central corneal thickness were routinely undertaken within two hours post-mortem. Only eyes free of obvious mechanical damage or disease were used. From measurements on 736 quality-selected and trimmed eyes, globe wet mass ranged from 10.4 to 25.2 g, horizontal corneal diameter from 19.0 to 26.5 mm and central corneal thickness measured by ultrasonic pachymetry from 0.543 to 0.836 mm (with an overall average of 690 ± 0.056 mm). The ocular globe mass was strongly correlated to horizontal corneal diameter (r 2 = 0.829). Central corneal thickness correlated with globe mass (r = 0.543) and to horizontal corneal diameter (r = 0.402). Based on the different anatomical measurements, a lamb's eye would be expected to have a thinner cornea (average 0.640 mm) than that of an adult outbred ewe (average 0.730 mm). In freshly procured eyes showing signs of slight corneal oedema, central corneal thickness was greater (average 0.856 ± 0.052 mm) and up to 24 hours of cold storage resulted in predictable increases in central corneal thickness of six to 24 per cent, especially in eyes showing signs of corneal oedema before storage. Based on the correlations obtained, differences in ovine eyes can be attributed to growth-related differences in the animals and thus, indirectly to their expected ages. A simple measure of the horizontal corneal diameter in ovine eyes used for laboratory studies would be a useful indicator in reporting these studies. © 2016 Optometry Australia.
NASA Astrophysics Data System (ADS)
Naveen, A.; Krishnamurthy, L.; Shridhar, T. N.
2018-04-01
Tungsten (W) and Alumina (Al2O3) thin films have been developed using co-sputtering technique on SS304, Copper (Cu) and Glass slides using Direct Current magnetron sputtering (DC) and Radio Frequency (RF) magnetron sputtering methods respectively. Central Composite Design (CCD) method approach has been adopted to determine the number of experimental plans for deposition and DC power, RF power and Argon gas flow rate have been input parameters, each at 5 levels for development of thin films. In this research paper, study has been carried out determine the optimized condition of deposition parameters for thickness and surface roughness of the thin films. Thickness and average Surface roughness in terms of nanometer (nm) have been characterized by thickness profilometer and atomic force microscopy respectively. The maximum and minimum average thickness observed to be 445 nm and 130 respectively. The optimum deposition condition for W/Al2O3 thin film growth was determined to be at 1000 watts of DC power and 800 watts of RF power, 20 minutes of deposition time, and almost 300 Standard Cubic Centimeter(SCCM) of Argon gas flow. It was observed that average roughness difference found to be less than one nanometer on SS substrate and one nanometer on copper approximately.
An approach for characterising cellular polymeric foam structures using computed tomography
NASA Astrophysics Data System (ADS)
Chen, Youming; Das, Raj; Battley, Mark
2018-02-01
Global properties of foams depend on foam base materials and microstructures. Characterisation of foam microstructures is important for developing numerical foam models. In this study, the microstructures of four polymeric structural foams were imaged using a micro-CT scanner. Image processing and analysis methods were proposed to quantify the relative density, cell wall thickness and cell size of these foams from the captured CT images. Overall, the cells in these foams are fairly isotropic, and cell walls are rather straight. The measured average relative densities are in good agreement with the actual values. Relative density, cell size and cell wall thickness in these foams are found to vary along the thickness of foam panel direction. Cell walls in two of these foams are found to be filled with secondary pores. In addition, it is found that the average cell wall thickness measured from 2D images is around 1.4 times of that measured from 3D images, and the average cell size measured from 3D images is 1.16 times of that measured from 2D images. The distributions of cell wall thickness and cell size measured from 2D images exhibit lager dispersion in comparison to those measured from 3D images.
The correlation between plantar fascia thickness and symptoms of plantar fasciitis.
Mahowald, Sarah; Legge, Bradford S; Grady, John F
2011-01-01
The purpose of this study was to determine whether changes in plantar fascia thickness are a reliable gauge of efficacy of treatment protocols for plantar fasciitis. Thirty-nine feet (30 patients) with plantar fasciitis received an ultrasound examination to measure the thickness of the medial band of the plantar fascia. Each patient assessed his or her pain using the visual analogue scale. Following various treatments, a second ultrasound examination was performed and the thickness of the plantar fascia was again measured and subjective pain level assessed. Twenty-nine feet (74.4%) showed a decrease in plantar fascia thickness and a decrease in pain. One foot (2.6%) experienced an increase in fascia thickness and reported an increase in pain. Four feet (10.3%) had an increase in thickness of the plantar fascia and reported no change in pain level. Three feet had minor increases in fascia thickness but reported a decrease in pain (7.7%). One foot (2.6%) had no change in fascia thickness but a decrease in pain and one foot (2.6%) had a decrease in the plantar fascia but no change in pain level. The average reduction in fascia thickness was 0.82 mm ± 1.04 mm, correlating with an average improvement in pain of 3.64 ± 2.7 (P < 0.005). This study provides evidence that changing thickness of the plantar fascia is a valid objective measurement to assess effectiveness of new or existing treatment protocols.
NASA Astrophysics Data System (ADS)
Belghith, Akram; Bowd, Christopher; Weinreb, Robert N.; Zangwill, Linda M.
2014-03-01
Glaucoma is an ocular disease characterized by distinctive changes in the optic nerve head (ONH) and visual field. Glaucoma can strike without symptoms and causes blindness if it remains without treatment. Therefore, early disease detection is important so that treatment can be initiated and blindness prevented. In this context, important advances in technology for non-invasive imaging of the eye have been made providing quantitative tools to measure structural changes in ONH topography, an essential element for glaucoma detection and monitoring. 3D spectral domain optical coherence tomography (SD-OCT), an optical imaging technique, has been commonly used to discriminate glaucomatous from healthy subjects. In this paper, we present a new framework for detection of glaucoma progression using 3D SD-OCT images. In contrast to previous works that the retinal nerve fiber layer (RNFL) thickness measurement provided by commercially available spectral-domain optical coherence tomograph, we consider the whole 3D volume for change detection. To integrate a priori knowledge and in particular the spatial voxel dependency in the change detection map, we propose the use of the Markov Random Field to handle a such dependency. To accommodate the presence of false positive detection, the estimated change detection map is then used to classify a 3D SDOCT image into the "non-progressing" and "progressing" glaucoma classes, based on a fuzzy logic classifier. We compared the diagnostic performance of the proposed framework to existing methods of progression detection.
Belghith, Akram; Bowd, Christopher; Weinreb, Robert N; Zangwill, Linda M
2014-03-18
Glaucoma is an ocular disease characterized by distinctive changes in the optic nerve head (ONH) and visual field. Glaucoma can strike without symptoms and causes blindness if it remains without treatment. Therefore, early disease detection is important so that treatment can be initiated and blindness prevented. In this context, important advances in technology for non-invasive imaging of the eye have been made providing quantitative tools to measure structural changes in ONH topography, an essential element for glaucoma detection and monitoring. 3D spectral domain optical coherence tomography (SD-OCT), an optical imaging technique, has been commonly used to discriminate glaucomatous from healthy subjects. In this paper, we present a new framework for detection of glaucoma progression using 3D SD-OCT images. In contrast to previous works that the retinal nerve fiber layer (RNFL) thickness measurement provided by commercially available spectral-domain optical coherence tomograph, we consider the whole 3D volume for change detection. To integrate a priori knowledge and in particular the spatial voxel dependency in the change detection map, we propose the use of the Markov Random Field to handle a such dependency. To accommodate the presence of false positive detection, the estimated change detection map is then used to classify a 3D SDOCT image into the "non-progressing" and "progressing" glaucoma classes, based on a fuzzy logic classifier. We compared the diagnostic performance of the proposed framework to existing methods of progression detection.
NASA Astrophysics Data System (ADS)
Chauhan, Shakti Singh
Metallic interconnects and circuitry has been experiencing excessive deformation beyond their elastic limits in many applications, ranging from micro-electromechanical systems (MEMS) to flexible electronics. These broad applications are creating needs to understand the extent of strength and ductility of freestanding metallic films at scales approaching the micron and sub micron range. This work aims to elucidate the effects of microstructural constraint as well as geometric dimensional constraint on the strength and ductility of freestanding Cu films under uniaxial tension. Two types of films are tested (i) high purity rolled films of 12.5-100microm thickness and average grain sizes of 11-47microm and (ii) electroplated films of 2-50 microm thickness and average grain sizes of 1.8-5microm. Several experimental tools including residual electrical resistivity measurements, surface strain measurements and surface roughness measurements are employed to highlight the underlying deformation mechanisms leading to the observed size effects. With respect to the strength of the specimens, we find that the nature and magnitude of thickness effects is very sensitive to the average grain size. In all cases, coupled thickness and grain size effects were observed. This study shows that this observed coupling, unique to the case of freestanding specimen, arises because the observed size effects are an outcome of the size dependence of two fundamental microstructural parameters i.e. volume fraction of surface grains and grain boundary area per unit specimen volume. For films having thickness and grain sizes greater than 5microm, thickness dependent weakening is observed for a constant grain size. Reducing thickness results in an increase in the volume fraction of grains exposed to the free surface as well as a reduction in the grain boundary area per unit specimen volume. The former effect leads to a reduction in the effective microstructural constraint on the intragranular dislocation activity in individual grains. This free surface related effect is the origin of a weakening contribution to the overall specimen strength with reducing thickness. For specimens with grain sizes ˜ O (10-50microm), this effect was found to be dominating i.e. reducing thickness resulted in reducing strength. A phenomenological model employing the flow strength of surface and bulk grains is proposed to model the observed trends. For films having thickness and grain sizes smaller than 5microm, size dependent strengthening is observed for a constant grain size. At this scale, grain boundary dislocations dominate. As a consequence, thickness effects arise because grain boundary dislocation source density per unit specimen volume reduces with reducing specimen thickness. This statistical reduction in dislocation source density leads to increasing specimen strength via source starvation strengthening. Our results show that such increasing specimen strength with reducing thickness, which has only been observed previously for nanocrystalline thin films, first appears at average grain size of ˜5microm or xx smaller. The measurements showed a characteristic length scale of about 5microm, which defines the size dependent strengthening or weakening of the film. With respect to the thickness effects on ductility, it was found that both thickness and average grain size affect ductility. While prominent thickness effects persist at larger grain sizes, for specimens with grain size approaching 1microm, the loss of strain hardening ability at such fine microstructures dominates and a limiting ductility of ˜2% is seen irrespective of the thickness. The observed thickness effects on ductility were investigated via surface roughness measurements that allow the characterization of initiation and evolution of deformation heterogeneities. It was found that thickness has a strong influence on the characteristic heterogeneity of deformation. At small specimen thicknesses, the deformation was found to be highly localized i.e. widely spaced regions showing substantial thickness reduction, hence increasing the vulnerability to the onset of plastic instabilities. At larger thicknesses, however, the increasing microstructural constraint delocalizes the strain and thereby precludes the early onset of instability, leading to enhanced ductility.
Live cell refractometry using Hilbert phase microscopy and confocal reflectance microscopy.
Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Yaqoob, Zahid; Badizadegan, Kamran; Dasari, Ramachandra R; Feld, Michael S
2009-11-26
Quantitative chemical analysis has served as a useful tool for understanding cellular metabolisms in biology. Among many physical properties used in chemical analysis, refractive index in particular has provided molecular concentration that is an important indicator for biological activities. In this report, we present a method of extracting full-field refractive index maps of live cells in their native states. We first record full-field optical thickness maps of living cells by Hilbert phase microscopy and then acquire physical thickness maps of the same cells using a custom-built confocal reflectance microscope. Full-field and axially averaged refractive index maps are acquired from the ratio of optical thickness to physical thickness. The accuracy of the axially averaged index measurement is 0.002. This approach can provide novel biological assays of label-free living cells in situ.
Live Cell Refractometry Using Hilbert Phase Microscopy and Confocal Reflectance Microscopy†
Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Yaqoob, Zahid; Badizadegan, Kamran; Dasari, Ramachandra R.; Feld, Michael S.
2010-01-01
Quantitative chemical analysis has served as a useful tool for understanding cellular metabolisms in biology. Among many physical properties used in chemical analysis, refractive index in particular has provided molecular concentration that is an important indicator for biological activities. In this report, we present a method of extracting full-field refractive index maps of live cells in their native states. We first record full-field optical thickness maps of living cells by Hilbert phase microscopy and then acquire physical thickness maps of the same cells using a custom-built confocal reflectance microscope. Full-field and axially averaged refractive index maps are acquired from the ratio of optical thickness to physical thickness. The accuracy of the axially averaged index measurement is 0.002. This approach can provide novel biological assays of label-free living cells in situ. PMID:19803506
Kahle, Sue C.; Olsen, Theresa D.; Fasser, Elisabeth T.
2013-01-01
A study of the hydrogeologic framework of the Little Spokane River Basin was conducted to identify and describe the principal hydrogeologic units in the study area, their hydraulic characteristics, and general directions of groundwater movement. The Little Spokane River Basin includes an area of 679 square miles in northeastern Washington State covering parts of Spokane, Stevens, and Pend Oreille Counties. The groundwater system consists of unconsolidated sedimentary deposits and isolated, remnant basalt layers overlying crystalline bedrock. In 1976, a water resources program for the Little Spokane River was adopted into rule by the State of Washington, setting instream flows for the river and closing its tributaries to further uses. Spokane County representatives are concerned about the effects that additional groundwater development within the basin might have on the Little Spokane River and on existing groundwater resources. Information provided by this study will be used in future investigations to evaluate the effects of potential increases in groundwater withdrawals on groundwater and surface-water resources in the basin. The hydrogeologic framework consists of eight hydrogeologic units: the Upper aquifer, Upper confining unit, Lower aquifers, Lower confining unit, Wanapum basalt unit, Latah unit, Grande Ronde basalt unit, and Bedrock. The Upper aquifer is composed mostly of sand and gravel and varies in thickness from 4 to 360 ft, with an average thickness of 70 ft. The aquifer is generally finer grained in areas farther from main outwash channels. The estimated horizontal hydraulic conductivity ranges from 4.4 to 410,000 feet per day (ft/d), with a median hydraulic conductivity of 900 ft/d. The Upper confining unit is a low-permeability unit consisting mostly of silt and clay, and varies in thickness from 5 to 400 ft, with an average thickness of 100 ft. The estimated horizontal hydraulic conductivity ranges from 0.5 to 5,600 ft/d, with a median hydraulic conductivity of 8.2 ft/d. The Lower aquifers unit consists of localized confined aquifers or lenses consisting mostly of sand that occur at depth in various places in the basin; thickness of the unit ranges from 8 to 150 ft, with an average thickness of 50 ft. The Lower confining unit is a low-permeability unit consisting mostly of silt and clay; thickness of the unit ranges from 35 to 310 ft, with an average thickness of 130 ft. The Wanapum basalt unit includes the Wanapum Basalt of the Columbia River Basalt Group, thin sedimentary interbeds, and, in some places, overlying loess. The unit occurs as isolated remnants on the basalt bluffs in the study area and ranges in thickness from 7 to 140 ft, with an average thickness of 60 ft. The Latah unit is a mostly low-permeability unit consisting of silt, clay, and sand that underlies and is interbedded with the basalt units. The Latah unit ranges in thickness from 10 to 700 ft, with an average thickness of 250 ft. The estimated horizontal hydraulic conductivity ranges from 0.19 to 15 ft/d, with a median hydraulic conductivity of 0.56 ft/d. The Grande Ronde unit includes the Grande Ronde Basalt of the Columbia River Basalt Group and sedimentary interbeds. Unit thickness ranges from 30 to 260 ft, with an average thickness of 140 ft. The estimated horizontal hydraulic conductivity ranges from 0.03 to 13 ft/d, with a median hydraulic conductivity of 2.9 ft/d. The Bedrock unit is the only available source of groundwater where overlying sediments are absent or insufficiently saturated. The estimated horizontal hydraulic conductivity ranges from 0.01 to 5,000 ft/d, with a median hydraulic conductivity of 1.4 ft/d. The altitude of the buried bedrock surface ranges from about 2,200 ft to about 1,200 ft. Groundwater movement in the Little Spokane River Basin mimics the surface-water drainage pattern of the basin, moving from the topographically high tributary-basin areas toward the topographically lower valley floors. Water-level altitudes range from more than 2,700 ft to about 1,500 ft near the basin’s outlet.
Downie, Jeanine; Kaspar, Miroslav
2016-04-01
Noninvasive body shaping methods seem to be an ascending part of the aesthetics market. As a result, the pressure to develop reliable methods for the collection and presentation of their results has also increased. The most used techniques currently include ultrasound measurements of fat thickness in the treated area, caliper measurements, bioimpedance-based scale measurements or circumferential tape measurements. Although these are the most used techniques, almost all of them have some limitations in reproducibility and/or accuracy. This study shows Magnetic Resonance Imaging (MRI) as the new method for the presentation of results in the body shaping industry. Six subjects were treated by a contactless selective radiofrequency device (BTL Vanquish ME, BTL Industries Inc., Boston, MA). The MRI fat thickness was measured at the baseline and at 4-weeks following the treatment. In addition to MRI images and measurements, digital photographs and anthropometric evaluations such as weight, abdominal circumference, and caliper fat thickness measurements were recorded. Abdominal fat thickness measurements from the MRI were performed from the same slices determined by the same tissue artefacts. The MRI fat thickness difference between the baseline measurement and follow up visit showed an average reduction of 5.36 mm as calculated from the data of 5 subjects. One subject dropped out of study due to non-study related issues. The results were statistically significant based on the Student's T-test evaluation. Magnetic resonance imaging abdominal fat thickness measurements seems to be the best method for the evaluation of fat thickness reduction after non-invasive body shaping treatments. In this study, this method shows average fat thickness reduction of 5.36 mm while the weight of the subjects didn't change significantly. A large spot size measuring 1317 cm(2) (204 square inches) covers the abdomen flank to flank. The average thickness of 5.36 mm of the fat layer reduced under the applicator translates into significant cumulative circumferential reduction. The reduction was not related with dieting.
Effect of Amblyopia Treatment on Macular Thickness in Eyes With Myopic Anisometropic Amblyopia.
Pang, Yi; Frantz, Kelly A; Block, Sandra; Goodfellow, Geoffrey W; Allison, Christine
2015-04-01
To determine whether abnormal macular thickness in myopic anisometropic amblyopia differed after amblyopia treatment. Furthermore, to investigate whether effect of treatment on macular thickness was associated with subject age or improvement in stereoacuity. Seventeen children (mean age: 9.0 [±3.0] years, ranging from 5.7-13.9 years) with myopic anisometropic amblyopia (visual acuity [VA] in amblyopic eyes: 20/80-20/400) were recruited and treated with 16-week refractive correction, followed by an additional 16-week refractive correction and patching. Macular thickness, best-corrected VA, and stereoacuity were measured both before and after amblyopia treatment. Factorial repeated-measures analysis of variance was performed to determine whether macular thickness in amblyopic eyes changed after amblyopia treatment. Mean baseline VA in the amblyopic eye was 1.0 ± 0.3 logMAR and improved to 0.7 ± 0.3 after amblyopia treatment (P < 0.0001). The interaction between eye and amblyopia treatment was statistically significant for average foveal thickness (P = 0.040). There was no treatment effect on fellow eyes (P = 0.245); however, the average foveal thickness in the amblyopic eye was significantly reduced after amblyopia treatment (P = 0.049). No statistically significant interactions were found for the other macular thickness parameters (P > 0.05). Abnormal central macula associated with myopic anisometropic amblyopia tended to be thinner following amblyopia treatment with no significant changes in peripheral macular thickness.
Laminate armor and related methods
Chu, Henry S; Lillo, Thomas M; Zagula, Thomas M
2013-02-26
Laminate armor and methods of manufacturing laminate armor. Specifically, laminate armor plates comprising a commercially pure titanium layer and a titanium alloy layer bonded to the commercially pure titanium outer layer are disclosed, wherein an average thickness of the titanium alloy inner layer is about four times an average thickness of the commercially pure titanium outer layer. In use, the titanium alloy layer is positioned facing an area to be protected. Additionally, roll-bonding methods for manufacturing laminate armor plates are disclosed.
Central Corneal Thickness in Children
2011-01-01
Objective To report the central corneal thickness (CCT) in healthy white, African-American, and Hispanic children from birth to 17 years of age. Design Prospective observational multicenter study. Central corneal thickness was measured with a hand-held contact pachymeter. Results Two thousand seventy-nine children were included in the study, with ages ranging from day of birth to 17 years. Included were 807 white, 494 Hispanic, and 474 African-American individuals, in addition to Asian, unknown and mixed race individuals. African-American children had thinner corneas on average than that of both white (p< .001) and Hispanic children (p< .001) by approximately 20 micrometers. Thicker median CCT was observed with each successive year of age from age 1 to 11 years, with year-to-year differences steadily decreasing and reaching a plateau after age 11 at 573 micrometers in white and Hispanic children and 551 micrometers in African-American children. For every 100 micrometers of thicker CCT measured, the intraocular pressure was 1.5 mmHg higher on average (p< 0.001). For every diopter of increased myopic refractive error (p< 0.001) CCT was 1 micrometer thinner on average. Conclusions Median CCT increases with age from 1 to 11 years with the greatest increase present in the youngest age groups. African-American children on average have thinner central corneas than white and Hispanic children, while white and Hispanic children demonstrate similar central corneal thickness. PMID:21911662
Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru; Kishi, Kazuo
2018-05-07
In nipple reconstruction, the width, length, and thickness of modified star flaps are concerns for long-term reconstructed nipple projection. However, the flap's projection has not been analyzed, based on its thickness. The aim of the present study was to investigate how flap thickness in a modified star flap influences the resulting reconstructed nipple and achieves an appropriate flap width in design. Sixty-three patients who underwent nipple reconstruction using a modified star flap following implant-based breast reconstruction between August 2014 and July 2016 were included in this case-controlled study. The length of laterally diverging flaps was 1.5 times their width. The thickness of each flap was measured using ultrasonography, and the average thickness was defined as the flap thickness. We investigated the correlation between the resulting reconstructed nipple and flap thickness, and the difference of the change in the reconstructed nipple projection after using a thin or thick flap. The average flap thickness was 3.8 ± 1.7 (range 2.5-6.0) mm. There was a significant, linear correlation between the flap thickness and resulting reconstructed nipple projection (β = 0.853, p < 0.01). Furthermore, the difference between the thin and thick flaps in the resulting reconstructed nipple projection was significant (p < 0.01). Measuring the flap thickness preoperatively may allow surgeons to achieve an appropriate flap width; otherwise, alternative methods for higher projection might be used. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Safety Performance of Exterior Wall Insulation Material Based on Large Security Concept
NASA Astrophysics Data System (ADS)
Zuo, Q. L.; Wang, Y. J.; Li, J. S.
2018-05-01
In order to evaluate the fire spread characteristics of building insulation materials under corner fire, an experiment is carried out with small-scale fire spread test system. The change rule of the parameters such as the average height of the flame, the average temperature of the flame and the shape of the flame are analyzed. The variations of the fire spread characteristic parameters of the building insulation materials are investigated. The results show that the average temperature of Expanded Polystyrene (EPS) board, with different thickness, decrease - rise - decrease - increase. During the combustion process, the fire of 4cm thick plate spreads faster.
Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.
Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M
2016-02-01
Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P < 0.0001)] The fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.
Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.
Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M
2015-07-01
Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were no readmissions for further debridement or skin grafting. Our experience shows that patients may be discharged shortly after the application of the copolymer dressing, with manageable pain scores and ease of use as determined by the caretakers high satisfaction. This new, fully synthetic copolymer dressing is easy to apply, does not require any additional antimicrobial coverage and may be used to successfully manage deeper partial-thickness burns, donor sites or burns in areas of contour, where many other dressings might not be considered or be appropriate. None declared.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Grenacher, L.; Stampfl, U.
The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 {mu}m). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury,more » vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 {mu}m. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 {mu}m and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.« less
Sehi, Mitra; Guaqueta, Delia C.; Feuer, William J.; Greenfield, David S.
2007-01-01
Purpose To investigate whether correction for atypical birefringence pattern (ABP) using scanning laser polarimetry with enhanced corneal compensation (SLP-ECC) reduces the severity of ABP compared with variable corneal compensation (SLP-VCC), and improves the correlation with visual function. Design Prospective observational study. Methods Normal and glaucomatous eyes enrolled from 4 clinical sites underwent complete examination, automated perimetry, SLP-ECC and SLP-VCC. Eyes were characterized in 3 groups based upon the typical scan score (TSS): normal birefringence pattern (NBP) was defined as TSS 80, mild ABP as TSS 61–79, moderate-severe ABP as TSS 60. For each of 4 SLP parameters the area under the ROC curve (AUROC) was calculated to compare the ability of SLP-ECC and SLP-VCC to discriminate between normal and glaucomatous eyes. Results Eighty-four normal volunteers and 45 glaucoma patients were enrolled. Mean TSS was significantly (p<0.001) greater using SLP-ECC (98.0 ± 6.6) compared to SLP-VCC (83.4 ± 22.5). The frequency of moderate-severe ABP images was significantly (p<0.001, McNemar test) higher using SLP-VCC (18 of 129, 14%) compared to SLP-ECC (1 of 129, 0.8%). Two SLP-ECC parameters (TSNIT average and inferior average) had significantly (p=0.01, p<0.001) higher correlation (r=0.45, r=0.50 respectively) with MD compared to SLP-VCC (r=0.34, r=0.37). Among eyes with moderate-severe ABP (N = 18), inferior average obtained using SLP-ECC had significantly (p=0.03) greater AUROC (0.91 ± 0.07) compared with SLP-VCC (0.78 ± 0.11). Conclusions SLP-ECC significantly reduces the frequency and severity of ABP compared to SLP-VCC and improves the correlation between RNFL measures and visual function. PMID:17157800
Characteristics of eyes with inner retinal cleavage.
Hwang, Young Hoon; Kim, Yong Yeon; Kim, Hwang Ki; Sohn, Yong Ho
2015-02-01
Inner retinal cleavage can be misdiagnosed as a glaucomatous retinal nerve fiber layer (RNFL) defect. This study was performed to characterize eyes with inner retinal cleavage. Inner retinal cleavage is defined as the appearance of a dark spindle-shaped space between the nerve fibers. Patients who presented at our institution with inner retinal cleavage were enrolled in the study. All participants were evaluated by fundus examination, visual field testing with standard automated perimetry, and optical coherence tomography (OCT) imaging. A total of 15 eyes of 11 subjects with inner retinal cleavage were included in the study. The median age of the subjects was 57 years (age range, 30-67 years). In each case, inner retinal cleavage was located adjacent to retinal blood vessels. Tissue bridging the cleavage area was observed in ten eyes. Six eyes had epiretinal membranes (ERMs), two eyes had glaucoma, and one eye had ERM in addition to glaucoma. Six eyes with inner retinal cleavage without combined ocular abnormalities had highly myopic refractive error (-6.50 to -8.50 diopters). Cross-sectional OCT images of the areas of inner retinal cleavage demonstrated defects with irregular margins and empty spaces in the inner layers of the retina. During the follow-up period, no eye showed changes in inner retinal layer cleavage or visual field sensitivity. Inner retinal cleavage was found in eyes with high myopia or ERMs. Inner retinal cleavage was associated with structural changes distinct from those associated with glaucomatous RNFL defects.
Linezolid-induced optic neuropathy with a rare pathological change in the inner retina.
Ishii, Nobuhito; Kinouchi, Reiko; Inoue, Masatomo; Yoshida, Akitoshi
2016-12-01
We report a case of linezolid-induced optic neuropathy with transient microcystic spaces in the inner retina. We observed the retina using Fourier-domain optical coherence tomography (FD-OCT) in a patient with linezolid-induced optic neuropathy. A 49-year-old woman presented to our department with a 1-week history of bilateral photophobia. At the first visit, her best-corrected visual acuity (VA) was 0.6 in the right eye and 0.5 in the left eye. She had moderate optic disk edema and central scotomas bilaterally. FD-OCT showed bilateral microcystic spaces in the retina. Microcystic spaces were seen in the retinal nerve fiber layer (RNFL) and at the border of the RNFL and the retinal ganglion cell layer. Magnetic resonance imaging and laboratory tests showed no positive findings except for an elevated lactic acid level. One week after the first visit, the VA levels decreased to 0.06 and 0.07 in the right and left eyes, respectively. Because the patient had a 7-month history of linezolid treatment for persistent pyogenic arthritis, we suspected linezolid-induced optic neuropathy and immediately terminated treatment with this drug. The optic disk edema and the microcystic spaces in the retina resolved, and the VA improved to 1.2 at 6 weeks after linezolid withdrawal. Microcystic spaces, which resolved with linezolid withdrawal, were observed in linezolid-induced optic neuropathy. The microcystic spaces in the inner retina can be the first retinal sign of some optic neuropathies.
Obsidian hydration dates glacial loading?
Friedman, I.; Pierce, K.L.; Obradovich, J.D.; Long, W.D.
1973-01-01
Three different groups of hydration rinds have been measured on thin sections of obsidian from Obsidian Cliff, Yellowstone National Park, Wyoming . The average thickness of the thickest (oldest) group of hydration rinds is 16.3 micrometers and can be related to the original emplacement of the flow 176,000 years ago (potassium-argon age). In addition to these original surfaces, most thin sections show cracks and surfaces which have average hydration rind thicknesses of 14.5 and 7.9 micrometers. These later two hydration rinds compare closely in thickness with those on obsidian pebbles in the Bull Lake and Pinedale terminal moraines in the West Yellowstone Basin, which are 14 to 15 and 7 to 8 micrometers thick, respectively. The later cracks are thought to have been formed by glacial loading during the Bull Lake and Pinedale glaciations, when an estimated 800 meters of ice covered the Obsidian Cliff flow.
Obsidian hydration dates glacial loading?
Friedman, I; Pierce, K L; Obradovich, J D; Long, W D
1973-05-18
Three different groups of hydration rinds have been measured on thin sections of obsidian from Obsidian Cliff, Yellowstone National Park, Wyoming. The average thickness of the thickest (oldest) group of hydration rinds is 16.3 micrometers and can be related to the original emplacement of the flow 176,000 years ago (potassium-argon age). In addition to these original surfaces, most thin sections show cracks and surfaces which have average hydration rind thicknesses of 14.5 and 7.9 micrometers. These later two hydration rinds compare closely in thickness with those on obsidian pebbles in the Bull Lake and Pinedale terminal moraines in the West Yellowstone Basin, which are 14 to 15 and 7 to 8 micrometers thick, respectively. The later cracks are thought to have been formed by glacial loading during the Bull Lake and Pinedale glaciations, when an estimated 800 meters of ice covered the Obsidian Cliff flow.
Damin, Craig A.; Nguyen, Vy H. T.; Niyibizi, Auguste S.; ...
2015-02-11
In this study, near-infrared scanning angle (SA) Raman spectroscopy was utilized to determine the interface location in bilayer films (a stack of two polymer layers) of polystyrene (PS) and polycarbonate (PC). Finite-difference-time-domain (FDTD) calculations of the sum square electric field (SSEF) for films with total bilayer thicknesses of 1200–3600 nm were used to construct models for simultaneously measuring the film thickness and the location of the buried interface between the PS and PC layers. Samples with total thicknesses of 1320, 1890, 2300, and 2750 nm and varying PS/PC interface locations were analyzed using SA Raman spectroscopy. Comparing SA Raman spectroscopymore » and optical profilometry measurements, the average percent difference in the total bilayer thickness was 2.0% for films less than ~2300 nm thick. The average percent difference in the thickness of the PS layer, which reflects the interface location, was 2.5% when the PS layer was less than ~1800 nm. SA Raman spectroscopy has been shown to be a viable, non-destructive method capable of determining the total bilayer thickness and buried interface location for bilayer samples consisting of thin polymer films with comparable indices of refraction.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jincheng; Shi, Chengwu, E-mail: shicw506@foxmail.com; Chen, Junjun
2016-06-15
In this paper, the ultra-thin and high-quality WO{sub 3} compact layers were successfully prepared by spin-coating-pyrolysis method using the tungsten isopropoxide solution in isopropanol. The influence of WO{sub 3} and TiO{sub 2} compact layer thickness on the photovoltaic performance of planar perovskite solar cells was systematically compared, and the interface charge transfer and recombination in planar perovskite solar cells with TiO{sub 2} compact layer was analyzed by electrochemical impedance spectroscopy. The results revealed that the optimum thickness of WO{sub 3} and TiO{sub 2} compact layer was 15 nm and 60 nm. The planar perovskite solar cell with 15 nm WO{submore » 3} compact layer gave a 9.69% average and 10.14% maximum photoelectric conversion efficiency, whereas the planar perovskite solar cell with 60 nm TiO{sub 2} compact layer achieved a 11.79% average and 12.64% maximum photoelectric conversion efficiency. - Graphical abstract: The planar perovskite solar cell with 15 nm WO{sub 3} compact layer gave a 9.69% average and 10.14% maximum photoelectric conversion efficiency, whereas the planar perovskite solar cell with 60 nm TiO{sub 2} compact layer achieved a 11.79% average and 12.64% maximum photoelectric conversion efficiency. Display Omitted - Highlights: • Preparation of ultra-thin and high-quality WO{sub 3} compact layers. • Perovskite solar cell with 15 nm-thick WO{sub 3} compact layer achieved PCE of 10.14%. • Perovskite solar cell with 60 nm-thick TiO{sub 2} compact layer achieved PCE of 12.64%.« less
Ho, Kai-Yu; Keyak, Joyce H; Powers, Christopher M
2014-01-03
Elevated bone principal strain (an indicator of potential bone injury) resulting from reduced cartilage thickness has been suggested to contribute to patellofemoral symptoms. However, research linking patella bone strain, articular cartilage thickness, and patellofemoral pain (PFP) remains limited. The primary purpose was to determine whether females with PFP exhibit elevated patella bone strain when compared to pain-free controls. A secondary objective was to determine the influence of patella cartilage thickness on patella bone strain. Ten females with PFP and 10 gender, age, and activity-matched pain-free controls participated. Patella bone strain fields were quantified utilizing subject-specific finite element (FE) models of the patellofemoral joint (PFJ). Input parameters for the FE model included (1) PFJ geometry, (2) elastic moduli of the patella bone, (3) weight-bearing PFJ kinematics, and (4) quadriceps muscle forces. Using quasi-static simulations, peak and average minimum principal strains as well as peak and average maximum principal strains were quantified. Cartilage thickness was quantified by computing the perpendicular distance between opposing voxels defining the cartilage edges on axial plane magnetic resonance images. Compared to the pain-free controls, individuals with PFP exhibited increased peak and average minimum and maximum principal strain magnitudes in the patella. Additionally, patella cartilage thickness was negatively associated with peak minimum principal patella strain and peak maximum principal patella strain. The elevated bone strain magnitudes resulting from reduced cartilage thickness may contribute to patellofemoral symptoms and bone injury in persons with PFP. © 2013 Published by Elsevier Ltd.
Levan, Ashley; Black, Garrett; Mietchen, Jonathan; Baxter, Leslie; Brock Kirwan, C; Gale, Shawn D
2016-12-01
Cognitive and social outcomes may be negatively affected in children with a history of traumatic brain injury (TBI). We hypothesized that executive function would mediate the association between right frontal pole cortical thickness and problematic social behaviors. Child participants with a history of TBI were recruited from inpatient admissions for long-term follow-up (n = 23; average age = 12.8, average time post-injury =3.2 years). Three measures of executive function, the Trail Making Test, verbal fluency test, and the Conners' Continuous Performance Test-Second edition (CPT-II), were administered to each participant while caregivers completed the Childhood Behavior Checklist (CBCL). All participants underwent brain magnetic resonance imaging following cognitive testing. Regression analysis demonstrated right frontal pole cortical thickness significantly predicted social problems. Measures of executive functioning also significantly predicted social problems; however, the mediation model testing whether executive function mediated the relationship between cortical thickness and social problems was not statistically significant. Right frontal pole cortical thickness and omission errors on the CPT-II predicted Social Problems on the CBCL. Results did not indicate that the association between cortical thickness and social problems was mediated by executive function.
Assessment of corneal epithelial thickness in dry eye patients.
Cui, Xinhan; Hong, Jiaxu; Wang, Fei; Deng, Sophie X; Yang, Yujing; Zhu, Xiaoyu; Wu, Dan; Zhao, Yujin; Xu, Jianjiang
2014-12-01
To investigate the features of corneal epithelial thickness topography with Fourier-domain optical coherence tomography (OCT) in dry eye patients. In this cross-sectional study, 100 symptomatic dry eye patients and 35 normal subjects were enrolled. All participants answered the ocular surface disease index questionnaire and were subjected to OCT, corneal fluorescein staining, tear breakup time, Schirmer 1 test without anesthetic (S1t), and meibomian morphology. Several epithelium statistics for each eye, including central, superior, inferior, minimum, maximum, minimum - maximum, and map standard deviation, were averaged. Correlations of epithelial thickness with the symptoms of dry eye were calculated. The mean (±SD) central, superior, and inferior corneal epithelial thickness was 53.57 (±3.31) μm, 52.00 (±3.39) μm, and 53.03 (±3.67) μm in normal eyes and 52.71 (±2.83) μm, 50.58 (±3.44) μm, and 52.53 (±3.36) μm in dry eyes, respectively. The superior corneal epithelium was thinner in dry eye patients compared with normal subjects (p = 0.037), whereas central and inferior epithelium were not statistically different. In the dry eye group, patients with higher severity grades had thinner superior (p = 0.017) and minimum (p < 0.001) epithelial thickness, more wide range (p = 0.032), and greater deviation (p = 0.003). The average central epithelial thickness had no correlation with tear breakup time, S1t, or the severity of meibomian glands, whereas average superior epithelial thickness positively correlated with S1t (r = 0.238, p = 0.017). Fourier-domain OCT demonstrated that the thickness map of the dry eye corneal epithelium was thinner than normal eyes in the superior region. In more severe dry eye disease patients, the superior and minimum epithelium was much thinner, with a greater range of map standard deviation.
NASA Astrophysics Data System (ADS)
Nield, Grace A.; Whitehouse, Pippa L.; van der Wal, Wouter; Blank, Bas; O'Donnell, John Paul; Stuart, Graham W.
2018-04-01
Differences in predictions of Glacial Isostatic Adjustment (GIA) for Antarctica persist due to uncertainties in deglacial history and Earth rheology. The Earth models adopted in many GIA studies are defined by parameters that vary in the radial direction only and represent a global average Earth structure (referred to as 1D Earth models). Over-simplifying actual Earth structure leads to bias in model predictions in regions where Earth parameters differ significantly from the global average, such as West Antarctica. We investigate the impact of lateral variations in lithospheric thickness on GIA in Antarctica by carrying out two experiments that use different rheological approaches to define 3D Earth models that include spatial variations in lithospheric thickness. The first experiment defines an elastic lithosphere with spatial variations in thickness inferred from seismic studies. We compare the results from this 3D model with results derived from a 1D Earth model that has a uniform lithospheric thickness defined as the average of the 3D lithospheric thickness. Irrespective of deglacial history and sub-lithospheric mantle viscosity, we find higher gradients of present-day uplift rates (i.e. higher amplitude and shorter wavelength) in West Antarctica when using the 3D models, due to the thinner-than-1D-average lithosphere prevalent in this region. The second experiment uses seismically-inferred temperature as input to a power-law rheology thereby allowing the lithosphere to have a viscosity structure. Modelling the lithosphere with a power-law rheology results in behaviour that is equivalent to a thinner-lithosphere model, and it leads to higher amplitude and shorter wavelength deformation compared with the first experiment. We conclude that neglecting spatial variations in lithospheric thickness in GIA models will result in predictions of peak uplift and subsidence that are biased low in West Antarctica. This has important implications for ice-sheet modelling studies as the steeper gradients of uplift predicted from the more realistic 3D model may promote stability in marine-grounded regions of West Antarctica. Including lateral variations in lithospheric thickness, at least to the level of considering West and East Antarctica separately, is important for capturing short wavelength deformation and it has the potential to provide a better fit to GPS observations as well as an improved GIA correction for GRACE data.
Pepin, Scott R; Griffith, Chad J; Wijdicks, Coen A; Goerke, Ute; McNulty, Margaret A; Parker, Josh B; Carlson, Cathy S; Ellermann, Jutta; LaPrade, Robert F
2009-11-01
There has recently been increased interest in the use of 7.0-T magnetic resonance imaging for evaluating articular cartilage degeneration and quantifying the progression of osteoarthritis. The purpose of this study was to evaluate articular cartilage cross-sectional area and maximum thickness in the medial compartment of intact and destabilized canine knees using 7.0-T magnetic resonance images and compare these results with those obtained from the corresponding histologic sections. Controlled laboratory study. Five canines had a surgically created unilateral grade III posterolateral knee injury that was followed for 6 months before euthanasia. The opposite, noninjured knee was used as a control. At necropsy, 3-dimensional gradient echo images of the medial tibial plateau of both knees were obtained using a 7.0-T magnetic resonance imaging scanner. Articular cartilage area and maximum thickness in this site were digitally measured on the magnetic resonance images. The proximal tibias were processed for routine histologic analysis with hematoxylin and eosin staining. Articular cartilage area and maximum thickness were measured in histologic sections corresponding to the sites of the magnetic resonance slices. The magnetic resonance imaging results revealed an increase in articular cartilage area and maximum thickness in surgical knees compared with control knees in all specimens; these changes were significant for both parameters (P <.05 for area; P <.01 for thickness). The average increase in area was 14.8% and the average increase in maximum thickness was 15.1%. The histologic results revealed an average increase in area of 27.4% (P = .05) and an average increase in maximum thickness of 33.0% (P = .06). Correlation analysis between the magnetic resonance imaging and histology data revealed that the area values were significantly correlated (P < .01), but the values for thickness obtained from magnetic resonance imaging were not significantly different from the histology sections (P > .1). These results demonstrate that 7.0-T magnetic resonance imaging provides an alternative method to histology to evaluate early osteoarthritic changes in articular cartilage in a canine model by detecting increases in articular cartilage area. The noninvasive nature of 7.0-T magnetic resonance imaging will allow for in vivo monitoring of osteoarthritis progression and intervention in animal models and humans for osteoarthritis.
SU-E-J-152: Evaluation of TrueBeam OBI V. 1.5 CBCT Performance in An Adaptive RT Environment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gardner, S; Studenski, M; Giaddui, T
2014-06-01
Purpose: To evaluate the image quality and imaging dose of the Varian TrueBeam OBIv.1.5 CBCT system in a clinical adaptive radiation therapy environment, simulated by changing phantom thickness. Methods: Various OBI CBCT protocols(Head, Pelvis, Thorax, Spotlight) were used to acquire images of Catphan504 phantom(nominal phantom thickness and 10 cm additional phantom thickness). The images were analyzed for low contrast detectability(CNR), uniformity(UI), and HU sensitivity. These results were compared to the same image sets for planning CT(pCT)(GE LightSpeed 16- slice). Imaging dose measurements were performed with Gafchromic XRQA2 film for various OBI protocols (Pelvis, Thorax, Spotlight) in a pelvic-sized phantom(nominal thicknessmore » and 4cm additional thickness). Dose measurements were acquired in the interior and at the surface of the phantom. Results: The nominal CNR[additional thickness CNR] for OBI was—Pelvis:1.45[0.81],Thorax:0.86[0.48], Spotlight:0.67[0.39],Head:0.28 [0.10]. The nominal CNR[additional thickness CNR] for pCT was— Pelvis:0.87[0.41],Head:0.60[0.22]. The nominal UI[additional thickness UI] for OBI was—Pelvis:11.5[24.1],Thorax:17.0[20.6], Spotlight:23.2[23.2], Head:15.6[59.9]. The nominal UI[additional thickness UI] for pCT was— Pelvis:9.2[8.6],Head:2.1[2.9]. The HU difference(averaged over all material inserts) between nominal and additional thickness scans for OBI: 8.26HU(Pelvis), 33.39HU(Thorax), 178.98HU(Head), 108.20HU (Spotlight); for pCT: 16.00HU(Pelvis), 19.85HU(Head). Uncertainties in electron density were calculated based on HU values with varying phantom thickness. Average electron-density deviations (ρ(water)=1)for GE-Pelvis, GE-Head, OBI-Pelvis, OBI-Thorax, OBI-Spotlight, and OBI-Head were: 0.0182, 0.0180, 0.0058, 0.0478, 0.2750, and 0.3115, respectively.The average phantom interior dose was(OBI-nominal):2.35cGy(Pelvis), 0.60cGy(Thorax), 1.87cGy(Spotlight); OBI-increased thickness: 1.77cGy(Pelvis), 0.43cGy(Thorax), 1.53cGy (Spotlight). Average surface dose(OBI-nominal): 2.29cGy(Pelvis), 0.56cGy(Thorax), 1.79cGy (Spotlight); OBI-increased thickness: 1.94cGy(Pelvis), 0.48cGy(Thorax), 1.47cGy (Spotlight). Conclusion: The OBI-Pelvis protocol offered comparable CNR and HU constancy to pCT for each geometry; other protocols, particularly Spotlight and Head, exhibited lower HU constancy and CNR. The uniformity of pCT was superior to OBI for all protocols. CNR and UI were degraded for both systems/scan types with increased thickness. The OBI interior dose decreased by approximately 30% with additional thickness. This work was funded, in part, under a grant with the Pennsylvania Department of Health. The Department of Health specifically declaims responsibility for any analyses, interpretations, or conclusions.« less
Magnetic field directional discontinuities - Characteristics between 0.46 and 1.0 AU
NASA Technical Reports Server (NTRS)
Lepping, R. P.; Behannon, K. W.
1986-01-01
Based on Mariner 10 data, a statistical survey and an application of the Sonnerup-Cahill variance procedure to a visual identification with 1.2-s averages for time intervals corresponding to the equally spaced heliocentric distances of 1.0, 0.72 and 0.46 AU, are employed to study the characteristics of directional discontinuities (DDs) in the interplanetary magnetic field. Analysis using two methods demonstrated that the ratio of tangential discontinuities (TDs) to rotational discontinuities (RDs) decreased with decreasing radial distance. Decreases in average discontinuity thickness of 41 percent between 1.0 and 0.72 AU, and 56 percent between 1.0 and 0.46 AU, were found for both TDs and RDs, in agreement with Pioneer 10 data between 1 and 5 AU. Normalization of the individual DD thicknesses with respect to the estimated local proton gyroradius (R sub L) gave a nearly constant average thickness at the three locations, 36 + or - 5 R sub L, for both RDs and TDs.
Fundamental studies of black chrome for solar collector use
NASA Technical Reports Server (NTRS)
Mcdonald, G.; Buzek, B.; Curtis, H.
1976-01-01
The thicknesses of black chrome plated for various times have been measured from electron photomicrographs and correlated with the solar spectrum absorptance and infrared emittance as calculated from spectral reflectance measurements. The maximum absorptance is reached at an average thickness of 0.5 micrometer. The emittance increases only slightly up to 1.0 micrometer but increases rapidly at thickness above 1.0 micrometer.
Choulakian, Mazen Y; Li, Jennifer Y; Ramos, Samuel; Mannis, Mark J
2016-01-01
To evaluate the predictability and reproducibility of stromal bed thickness for single-pass donor Descemet stripping automated endothelial keratoplasty (DSAEK) tissue preparation, using the ML7 Microkeratome Donor Cornea System (Med-logics Inc, Athens, TX). In this retrospective chart review of 256 consecutive corneal tissue preparations for DSAEK surgery, from June 2013 to August 2014, tissue thicknesses were divided into 3 groups, depending on surgeon preference: <91 μm (group A), 90 to 120 μm (group B), and 120 to 160 μm (group C). Precut and postcut data were recorded. Average postcut donor corneal thickness was 114 ± 30 μm (range 60-183 μm), whereas the average in group A was 97 ± 23 μm (range 60-128), in group B was 113 ± 21 μm (range 77-179), and in group C was 134 ± 43 (range 89-183). Average postcut endothelial cell density was very adequate at 3013 ± 250 cells per square millimeter. There were a total of 7 failed procedures from 256 attempts, which represents a rate of 2.7%. This rate decreases to 1.5% when analyzing the last 200 cuts. The ML7 Microkeratome Donor Cornea System allows for reliable and reproducible DSAEK tissue preparation. Ultrathin DSAEK tissues can be prepared with a single-pass. Aiming for a graft thickness between 90 and 120 μm seems to be most reliable.
EDI OCT evaluation of choroidal thickness in Stargardt disease
Sodi, Andrea; Bacherini, Daniela; Caporossi, Orsola; Murro, Vittoria; Mucciolo, Dario Pasquale; Cipollini, Francesca; Passerini, Ilaria; Virgili, Gianni; Rizzo, Stanislao
2018-01-01
Purpose Choroidal thickness (CT) evaluation with EDI-OCT in Stargardt Disease (STGD), considering its possible association with some clinical features of the disease. Methods CT was evaluated in 41 STGD patients and in 70 controls. Measurements were performed in the subfoveal position and at 1000 μm nasally and temporally. CT average values in STGD and in the control group were first compared by means of Student’s T test. Then, the possible association between CT and some clinical features was evaluated by means of linear regression analysis. Considered clinical parameters were: age, age on onset, duration of the disease, visual acuity, foveal thickness, Fishman clinical phenotype, visual field loss and ERG response. Results Average CT was not significantly different between controls and STGD patients. In the STGD group the correlation between CT and age (r = 0.22, p = 0.033) and age of onset (r = 0.05, p = 0.424) was modest, while that of CT with disease duration (r = 0.30, p<0.001) was moderate. CT and foveal thickness were also significantly but modestly correlated (r = 0.15, p = 0.033). Conclusion In our series average CT is not significantly changed in STGD in comparison with the controls. Nevertheless a choroidal thinning may be identified in the more advanced stages of the disease. PMID:29304098
Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT.
Zhang, Li; Buitendijk, Gabriëlle H S; Lee, Kyungmoo; Sonka, Milan; Springelkamp, Henriët; Hofman, Albert; Vingerling, Johannes R; Mullins, Robert F; Klaver, Caroline C W; Abràmoff, Michael D
2015-05-01
To evaluate the validity of a novel fully automated three-dimensional (3D) method capable of segmenting the choroid from two different optical coherence tomography scanners: swept-source OCT (SS-OCT) and spectral-domain OCT (SD-OCT). One hundred eight subjects were imaged using SS-OCT and SD-OCT. A 3D method was used to segment the choroid and quantify the choroidal thickness along each A-scan. The segmented choroidal posterior boundary was evaluated by comparing to manual segmentation. Differences were assessed to test the agreement between segmentation results of the same subject. Choroidal thickness was defined as the Euclidian distance between Bruch's membrane and the choroidal posterior boundary, and reproducibility was analyzed using automatically and manually determined choroidal thicknesses. For SS-OCT, the average choroidal thickness of the entire 6- by 6-mm2 macular region was 219.5 μm (95% confidence interval [CI], 204.9-234.2 μm), and for SD-OCT it was 209.5 μm (95% CI, 197.9-221.0 μm). The agreement between automated and manual segmentations was high: Average relative difference was less than 5 μm, and average absolute difference was less than 15 μm. Reproducibility of choroidal thickness between repeated SS-OCT scans was high (coefficient of variation [CV] of 3.3%, intraclass correlation coefficient [ICC] of 0.98), and differences between SS-OCT and SD-OCT results were small (CV of 11.0%, ICC of 0.73). We have developed a fully automated 3D method for segmenting the choroid and quantifying choroidal thickness along each A-scan. The method yielded high validity. Our method can be used reliably to study local choroidal changes and may improve the diagnosis and management of patients with ocular diseases in which the choroid is affected.
Oh, Seon-Hee; Kim, Seok-Gyu
2015-10-01
The aim of the study was to evaluate the effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations. Three different types of disk-shaped zirconia coping specimens (Lava, Cercon, Zirkonzahn: ø10 mm × 0.4 mm) were fabricated and veneered with IPS e.max Press Ceram (shade A2), for total thicknesses of 1 and 1.5 mm. A total of sixty zirconia restoration specimens were divided into six groups based on their coping types and thicknesses. The abutment specimens (ø10 mm × 7 mm) were prepared with gold alloy, base metal (nickel-chromium) alloy, and four different shades (A1, A2, A3, A4) of composite resins. The average L*, a*, b* values of the zirconia specimens on the six abutment specimens were measured with a dental colorimeter, and the statistical significance in the effects of three variables was analyzed by using repeated measures analysis of variance (α=.05).The average shade difference (ΔE) values of the zirconia specimens between the A2 composite resin abutment and other abutments were also evaluated. The effects of zirconia specimen thickness (P<.001), abutment shade (P<.001), and type of zirconia copings (P<.003) on the final shade of the zirconia restorations were significant. The average ΔE value of Lava specimens (1 mm) between the A2 composite resin and gold alloy abutments was higher (close to the acceptability threshold of 5.5 ΔE) than th ose between the A2 composite resin and other abutments. This in-vitro study demonstrated that abutment shade, ceramic thickness, and coping type affected the resulting shade of zirconia restorations.
NASA Astrophysics Data System (ADS)
Minkov, D. A.; Gavrilov, G. M.; Moreno, J. M. D.; Vazquez, C. G.; Marquez, E.
2017-03-01
The accuracy of the popular graphical method of Swanepoel (SGM) for the characterization of a thin film on a substrate specimen from its interference transmittance spectrum depends on the subjective choice of four characterization parameters: the slope of the graph, the order number for the longest wavelength extremum, and the two numbers of the extrema used for the calculation approximations of the average film thickness. Here, an error metric is introduced for estimating the accuracy of SGM characterization. An algorithm is proposed for the optimization of SGM, named the OGM algorithm, based on the minimization of this error metric. Its execution provides optimized values of the four characterization parameters, and the respective computation of the most accurate film characteristics achievable within the framework of SGM. Moreover, substrate absorption is accounted for, unlike in the classical SGM, which is beneficial when using modern UV/visible/NIR spectrophotometers due to the relatively larger amount of absorption in the commonly used glass substrates for wavelengths above 1700 nm. A significant increase in the accuracy of the film characteristics is obtained employing the OGM algorithm compared to the SGM algorithm for two model specimens. Such improvements in accuracy increase with increasing film absorption. The results of the film characterization by the OGM algorithm are presented for two specimens containing RF-magnetron-sputtered a-Si films with disparate film thicknesses. The computed average film thicknesses are within 1.1% of the respective film thicknesses measured by SEM for both films. Achieving such high film characterization accuracy is particularly significant for the film with a computed average thickness of 3934 nm, since we are not aware of any other film with such a large thickness that has been characterized by SGM.
Tactile Responses to Vibration
NASA Astrophysics Data System (ADS)
Verrillo, Ronald T.; Bolanowski, Stanley J.
The skin is by far the largest organ of the human body having an area of approximately 1.85 m2 in the adult male and 1.65 m2 in the adult female with an average weight of about 9 lb., comprising about 6% of the total body weight. In thickness it ranges from an average of 4.4 mm in non-hairy skin to 2.1 mm in hairy skin. It is thin over the eyelids and thick at the soles of the feet. The human body contains four types of skin.
Increased Atherosclerosis Correlates with Subjective Tinnitus Severity.
Yüksel, Fatih; Karataş, Duran; Türkdoğan, Figen Tunalı; Yüksel, Özlem
2018-03-01
The aim of the present study was to investigate whether increased intima media thickness was associated with the severity of subjective non-pulsatile tinnitus and hearing loss. Data of the patients who came to Otorhinolaryngology Department of Isparta Government Hospital with subjective non-pulsatile tinnitus complaint, between January 2012 and June 2013, were evaluated retrospectively. A total of 215 patients were included in the present study. Hearing tests, biochemical analysis, tinnitus handicap inventory (THI), visual analogue scale (VAS) and doppler ultrasonography results of the patients were reviewed and recorded. The patients were classified into two groups as those having an increased intima media thickness and those having a normal intima media thickness. The said groups were compared with respect to age, gender, THI, VAS, hearing test findings and lipid values. Moreover, THI and VAS groups were compared with respect to intima-media thickness. In the group having increased intima-media thickness, THI and VAS average, frequency of hypertension, total cholesterol, low density lipoprotein and triglyceride averages and mean frequencies obtained by hearing test were significantly higher. Comparison of THI and VAS groups showed that intima-media thickness was significantly different between those having a mild tinnitus and those having a severe tinnitus. Increased intima-media thickness was associated with the severity of subjective non-pulsatile tinnitus and hearing loss. For this reason, the carotid system should be examined in subjective non-pulsatile tinnitus patients.
Abbott, Carla J; Choe, Tiffany E; Lusardi, Theresa A; Burgoyne, Claude F; Wang, Lin; Fortune, Brad
2014-02-04
To compare in vivo retinal nerve fiber layer thickness (RNFLT) and axonal transport at 1 and 2 weeks after an 8-hour acute IOP elevation in rats. Forty-seven adult male Brown Norway rats were used. Procedures were performed under anesthesia. The IOP was manometrically elevated to 50 mm Hg or held at 15 mm Hg (sham) for 8 hours unilaterally. The RNFLT was measured by spectral-domain optical coherence tomography. Anterograde and retrograde axonal transport was assessed from confocal scanning laser ophthalmoscopy imaging 24 hours after bilateral injections of 2 μL 1% cholera toxin B-subunit conjugated to AlexaFluor 488 into the vitreous or superior colliculi, respectively. Retinal ganglion cell (RGC) and microglial densities were determined using antibodies against Brn3a and Iba-1. The RNFLT in experimental eyes increased from baseline by 11% at 1 day (P < 0.001), peaked at 19% at 1 week (P < 0.0001), remained 11% thicker at 2 weeks (P < 0.001), recovered at 3 weeks (P > 0.05), and showed no sign of thinning at 6 weeks (P > 0.05). There was no disruption of anterograde transport at 1 week (superior colliculi fluorescence intensity, 75.3 ± 7.9 arbitrary units [AU] for the experimental eyes and 77.1 ± 6.7 AU for the control eyes) (P = 0.438) or 2 weeks (P = 0.188). There was no obstruction of retrograde transport at 1 week (RCG density, 1651 ± 153 per mm(2) for the experimental eyes and 1615 ± 135 per mm(2) for the control eyes) (P = 0.63) or 2 weeks (P = 0.25). There was no loss of Brn3a-positive RGC density at 6 weeks (P = 0.74) and no increase in microglial density (P = 0.92). Acute IOP elevation to 50 mm Hg for 8 hours does not cause a persisting axonal transport deficit at 1 or 2 weeks or a detectable RNFLT or RGC loss by 6 weeks but does lead to transient RNFL thickening that resolves by 3 weeks.
Abbott, Carla J.; Choe, Tiffany E.; Lusardi, Theresa A.; Burgoyne, Claude F.; Wang, Lin; Fortune, Brad
2014-01-01
Purpose. To compare in vivo retinal nerve fiber layer thickness (RNFLT) and axonal transport at 1 and 2 weeks after an 8-hour acute IOP elevation in rats. Methods. Forty-seven adult male Brown Norway rats were used. Procedures were performed under anesthesia. The IOP was manometrically elevated to 50 mm Hg or held at 15 mm Hg (sham) for 8 hours unilaterally. The RNFLT was measured by spectral-domain optical coherence tomography. Anterograde and retrograde axonal transport was assessed from confocal scanning laser ophthalmoscopy imaging 24 hours after bilateral injections of 2 μL 1% cholera toxin B-subunit conjugated to AlexaFluor 488 into the vitreous or superior colliculi, respectively. Retinal ganglion cell (RGC) and microglial densities were determined using antibodies against Brn3a and Iba-1. Results. The RNFLT in experimental eyes increased from baseline by 11% at 1 day (P < 0.001), peaked at 19% at 1 week (P < 0.0001), remained 11% thicker at 2 weeks (P < 0.001), recovered at 3 weeks (P > 0.05), and showed no sign of thinning at 6 weeks (P > 0.05). There was no disruption of anterograde transport at 1 week (superior colliculi fluorescence intensity, 75.3 ± 7.9 arbitrary units [AU] for the experimental eyes and 77.1 ± 6.7 AU for the control eyes) (P = 0.438) or 2 weeks (P = 0.188). There was no obstruction of retrograde transport at 1 week (RCG density, 1651 ± 153 per mm2 for the experimental eyes and 1615 ± 135 per mm2 for the control eyes) (P = 0.63) or 2 weeks (P = 0.25). There was no loss of Brn3a-positive RGC density at 6 weeks (P = 0.74) and no increase in microglial density (P = 0.92). Conclusions. Acute IOP elevation to 50 mm Hg for 8 hours does not cause a persisting axonal transport deficit at 1 or 2 weeks or a detectable RNFLT or RGC loss by 6 weeks but does lead to transient RNFL thickening that resolves by 3 weeks. PMID:24398096
[Diagnostic capability of PULSAR, FDT y HRT-II in glaucoma suspects].
González-de-la-Rosa, M; González-Hernández, M; Aguilar-Estévez, J; Díaz-Alemán, T; Armas-Plasencia, R
2007-07-01
To determine the diagnostic capability of PULSAR-T30W, FDT-Threshold-N30 and HRT-II in glaucoma suspects. Forty-seven eyes from 47 referred glaucoma suspects (GS) were examined twice with each technique. Cases with TOP-WW-MD>6dB were excluded. Results were compared with those of 70 eyes from 70 normal controls (C). Mean MD value using TOP-WW in the GS group (0.96dB. sd=1.7) was not significantly different from C (0.8dB. sd=1.77) (p>0.05). Disc area in GS group (2.12 mm(2). sd=0.34) was significantly greater than in C (1.97 mm2. sd=0.45) (p<0.01). For 95.7% specificity, PULSAR-sLV showed the highest sensitivity of 30.9% in individual examinations. The highest reproducible sensitivity in the two examinations was obtained using HRT-II maximum contour elevation (23.4%) and reference height (23.4%), and was 14.9% for various indices after correcting for the influence of disc area (cup area, cup/disc area ratio, maximum contour depression and mean RNFL thickness). Reproducible sensitivity of the perimetric indices was: PULSAR-MD=8.5%, PULSAR-sLV=17%, FDT-MD=6.4%, FDT-PSD=4.3%. The association of perimetric and HRT-II indices achieved high sensitivity but low diagnostic reproducibility. The most effective indices were maximum contour elevation, reference height and PULSAR-sLV, although the inclusion of the optic nerve head assessment in the selection of the GS sample may have favored the HRT-II results.
NASA Astrophysics Data System (ADS)
Instanes, Geir; Pedersen, Audun; Toppe, Mads; Nagy, Peter B.
2009-03-01
This paper describes a novel ultrasonic guided wave inspection technique for the monitoring of internal corrosion and erosion in pipes, which exploits the fundamental flexural mode to measure the average wall thickness over the inspection path. The inspection frequency is chosen so that the group velocity of the fundamental flexural mode is essentially constant throughout the wall thickness range of interest, while the phase velocity is highly dispersive and changes in a systematic way with varying wall thickness in the pipe. Although this approach is somewhat less accurate than the often used transverse resonance methods, it smoothly integrates the wall thickness over the whole propagation length, therefore it is very robust and can tolerate large and uneven thickness variations from point to point. The constant group velocity (CGV) method is capable of monitoring the true average of the wall thickness over the inspection length with an accuracy of 1% even in the presence of one order of magnitude larger local variations. This method also eliminates spurious variations caused by changing temperature, which can cause fairly large velocity variations, but do not significantly influence the dispersion as measured by the true phase angle in the vicinity of the CGV point. The CGV guided wave CEM method was validated in both laboratory and field tests.
Götzinger, Erich; Pircher, Michael; Baumann, Bernhard; Hirn, Cornelia; Vass, Clemens; Hitzenberger, Christoph K.
2010-01-01
Purpose To analyze the physical origin of atypical scanning laser polarimetry (SLP) patterns. To compare polarization-sensitive optical coherence tomography (PS-OCT) scans to SLP images. To present a method to obtain pseudo-SLP images by PS-OCT that are free of atypical artifacts. Methods Forty-one eyes of healthy subjects, subjects with suspected glaucoma, and patients with glaucoma were imaged by SLP (GDx VCC) and a prototype spectral domain PS-OCT system. The PS-OCT system acquires three-dimensional (3D) datasets of intensity, retardation, and optic axis orientation simultaneously within 3 seconds. B-scans of intensity and retardation and en face maps of retinal nerve fiber layer (RNFL) retardation were derived from the 3D PS-OCT datasets. Results were compared with those obtained by SLP. Results Twenty-two eyes showed atypical retardation patterns, and 19 eyes showed normal patterns. From the 22 atypical eyes, 15 showed atypical patterns in both imaging modalities, five were atypical only in SLP images, and two were atypical only in PS-OCT images. In most (15 of 22) atypical cases, an increased penetration of the probing beam into the birefringent sclera was identified as the source of atypical patterns. In such cases, the artifacts could be eliminated in PS-OCT images by depth segmentation and exclusion of scleral signals. Conclusions PS-OCT provides deeper insight into the contribution of different fundus layers to SLP images. Increased light penetration into the sclera can distort SLP retardation patterns of the RNFL. PMID:19036999
Park, H-Yl; Hwang, Y S; Park, C K
2017-04-01
PurposeTo investigate the clinical characteristics according to the location of focal lamina cribrosa (LC) defects and its associated ocular features.Patients and methodsA total of 139 open-angle glaucoma patients underwent Spectralis optical coherence tomography (OCT) with enhanced depth imaging. Alterations in the contour of the LC were investigated to find focal LC defects. The location of the visible LC defect from the neural canal wall (far-peripheral and mid-peripheral) and clock-hour position (superotemporal, temporal and inferotemporal) were classified. Disc ovality ratio and disc-foveal angle were measured from disc and retinal nerve fiber layer (RNFL) photographs. The disc tilt degree was measured using a Heidelberg Retina Tomograph (HRT) III system. The en face OCT image of the disc scans was registered to the disc and RNFL photographs, to determine whether the focal LC defects corresponded spatially to the glaucomatous damage location.ResultsEyes with far-peripheral LC defects were significantly myopic and had a higher disc ovality ratio. The disc tilt degree obtained by HRT revealed significant temporal disc tilt in eyes with temporal LC defects (P<0.001). Eyes with inferotemporal LC defects had a significantly larger disc-foveal angle (P=0.027). The inferotemporal LC defects corresponded to the location of glaucomatous damage in 81.6%; however, only 46.2% of eyes with a superotemporal LC defect and 3.2% of eyes with a temporal LC defect corresponded spatially with the glaucomatous damage location.ConclusionsThe clinical characteristics and association with glaucomatous damage location were different according to the location of focal LC defect.
Relationship among visual field, blood flow, and neural structure measurements in glaucoma.
Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David
2012-05-17
To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P < 0.001). Visual field loss was correlated with both reduced retinal blood flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.
Macular Diagnostic Ability in OCT for Assessing Glaucoma in High Myopia.
Hung, Kuo-Chi; Wu, Pei-Chang; Poon, Yi-Chieh; Chang, Hsueh-Wen; Lai, Ing-Chou; Tsai, Jen-Chia; Lin, Pei-Wen; Teng, Mei-Ching
2016-02-01
To compare the diagnostic abilities of spectral-domain optical coherence tomography (SD-OCT; Spectralis OCT) and time-domain OCT (TD-OCT; Stratus OCT). Changes in macular parameters in highly myopic eyes of glaucoma patients and highly myopic eyes of glaucoma suspects were evaluated and compared. We collected data from 72 highly myopic eyes (spherical equivalent, ≤-6.0D). Forty-one eyes had perimetric glaucoma and 31 eyes were suspected to have glaucoma (control group). All eyes underwent SD-OCT and TD-OCT imaging. Area under the receiver operating characteristic (AUROC) curve and sensitivity were examined on macular volume and thickness parameters at a fixed specificity and compared between groups. The highest TD-OCT AUROC curves were found using outer inferior sector macular thickness (AUROC curve, 0.911) and volume (AUROC curve, 0.909). The highest SD-OCT AUROC curves were found using outer inferior region thickness (AUROC curve, 0.836) and volume (AUROC curve, 0.834). The difference between the two imaging modalities was not statistically significant (thickness, p = 0.141; volume, p = 0.138). The sensitivity of TD-OCT macular outer inferior average thickness was highest and was 88.2%, with a specificity of 80.4%. The sensitivity of TD-OCT average volume measurements in this same region was 76.5%, with a specificity of 91.3%. The SD-OCT average thickness measurements also had the highest sensitivity in this region, which was 78.6%, with a specificity of 82.1%. The SD-OCT volume measurements had a sensitivity of 67.9%, with a specificity of 92.3%. Both SD-OCT and TD-OCT measurements of outer inferior macular thickness and volume can differentiate between eyes of glaucoma patients and glaucoma suspects with high myopia. These independent predictors all had good sensitivity. Based on our results, SD-OCT and TD-OCT have similar diagnostic abilities. These parameters may provide useful additional data in highly myopic eyes to complement standard glaucoma diagnosis tools.
NASA Astrophysics Data System (ADS)
Tetreault, J. L.; Buiter, S. J. H.
2014-07-01
Allochthonous accreted terranes are exotic geologic units that originated from anomalous crustal regions on a subducting oceanic plate and were transferred to the overriding plate during subduction by accretionary processes. The geographical regions that eventually become accreted allochthonous terranes include island arcs, oceanic plateaus, submarine ridges, seamounts, continental fragments, and microcontinents. These future allochthonous terranes (FATs) contribute to continental crustal growth, subduction dynamics, and crustal recycling in the mantle. We present a review of modern FATs and their accreted counterparts based on available geological, seismic, and gravity studies and discuss their crustal structure, geological origin, and bulk crustal density. Island arcs have an average crustal thickness of 26 km, average bulk crustal density of 2.79 g cm-3, and have 3 distinct crustal units overlying a crust-mantle transition zone. Oceanic plateaus and submarine ridges have an average crustal thickness of 21 km and average bulk crustal density of 2.84 g cm-3. Continental fragments presently on the ocean floor have an average crustal thickness of 25 km and bulk crustal density of 2.81 g cm-3. Accreted allochthonous terranes can be compared to these crustal compilations to better understand which units of crust are accreted or subducted. In general, most accreted terranes are thin crustal units sheared off of FATs and added onto the accretionary prism, with thicknesses on the order of hundreds of meters to a few kilometers. In addition many island arcs, oceanic plateaus, and submarine ridges were sheared off in the subduction interface and underplated onto the overlying continent. And other times we find evidence of collision leaving behind accreted terranes 25 to 40 km thick. We posit that rheologically weak crustal layers or shear zones that were formed when the FATs were produced can be activated as detachments during subduction, allowing parts of the FAT crust to accrete and others to accrete. In many modern FATs on the ocean floor, a sub-crustal layer of high seismic velocities, interpreted as ultramafic material, could serve as a detachment or delaminate during subduction.
NASA Astrophysics Data System (ADS)
Tetreault, J. L.; Buiter, S. J. H.
2014-12-01
Allochthonous accreted terranes are exotic geologic units that originated from anomalous crustal regions on a subducting oceanic plate and were transferred to the overriding plate by accretionary processes during subduction. The geographical regions that eventually become accreted allochthonous terranes include island arcs, oceanic plateaus, submarine ridges, seamounts, continental fragments, and microcontinents. These future allochthonous terranes (FATs) contribute to continental crustal growth, subduction dynamics, and crustal recycling in the mantle. We present a review of modern FATs and their accreted counterparts based on available geological, seismic, and gravity studies and discuss their crustal structure, geological origin, and bulk crustal density. Island arcs have an average crustal thickness of 26 km, average bulk crustal density of 2.79 g cm-3, and three distinct crustal units overlying a crust-mantle transition zone. Oceanic plateaus and submarine ridges have an average crustal thickness of 21 km and average bulk crustal density of 2.84 g cm-3. Continental fragments presently on the ocean floor have an average crustal thickness of 25 km and bulk crustal density of 2.81 g cm-3. Accreted allochthonous terranes can be compared to these crustal compilations to better understand which units of crust are accreted or subducted. In general, most accreted terranes are thin crustal units sheared off of FATs and added onto the accretionary prism, with thicknesses on the order of hundreds of meters to a few kilometers. However, many island arcs, oceanic plateaus, and submarine ridges were sheared off in the subduction interface and underplated onto the overlying continent. Other times we find evidence of terrane-continent collision leaving behind accreted terranes 25-40 km thick. We posit that rheologically weak crustal layers or shear zones that were formed when the FATs were produced can be activated as detachments during subduction, allowing parts of the FAT crust to accrete and others to subduct. In many modern FATs on the ocean floor, a sub-crustal layer of high seismic velocities, interpreted as ultramafic material, could serve as a detachment or delaminate during subduction.
Quantifying precambrian crustal extraction: The root is the answer
Abbott, D.; Sparks, D.; Herzberg, C.; Mooney, W.; Nikishin, A.; Zhang, Y.-S.
2000-01-01
We use two different methods to estimate the total amount of continental crust that was extracted by the end of the Archean and the Proterozoic. The first method uses the sum of the seismic thickness of the crust, the eroded thickness of the crust, and the trapped melt within the lithospheric root to estimate the total crustal volume. This summation method yields an average equivalent thickness of Archean crust of 49 ?? 6 km and an average equivalent thickness of Proterozoic crust of 48 ?? 9 km. Between 7 and 9% of this crust never reached the surface, but remained within the continental root as congealed, iron-rich komatiitic melt. The second method uses experimental models of melting, mantle xenolith compositions, and corrected lithospheric thickness to estimate the amount of crust extracted through time. This melt column method reveals that the average equivalent thickness of Archean crust was 65 ?? 6 km. and the average equivalent thickness of Early Proterozoic crust was 60 ?? 7 km. It is likely that some of this crust remained trapped within the lithospheric root. The discrepancy between the two estimates is attributed to uncertainties in estimates of the amount of trapped, congealed melt, overall crustal erosion, and crustal recycling. Overall, we find that between 29 and 45% of continental crust was extracted by the end of the Archean, most likely by 2.7 Ga. Between 51 and 79% of continental crust was extracted by the end of the Early Proterozoic, most likely by 1.8-2.0 Ga. Our results are most consistent with geochemical models that call upon moderate amounts of recycling of early extracted continental crust coupled with continuing crustal growth (e.g. McLennan, S.M., Taylor, S.R., 1982. Geochemical constraints on the growth of the continental crust. Journal of Geology, 90, 347-361; Veizer, J., Jansen, S.L., 1985. Basement and sedimentary recycling - 2: time dimension to global tectonics. Journal of Geology 93(6), 625-643). Trapped, congealed, iron-rich melt within the lithospheric root may represent some of the iron that is 'missing' from the lower crust. The lower crust within Archean cratons may also have an unexpectedly low iron content because it was extracted from more primitive, undepleted mantle. (C) 2000 Elsevier Science B.V. All rights reserved.
[Predictability of the corneal flap creation with the femtosecond laser in LASIK].
Mai, Zhi-bin; Liu, Su-bing; Nie, Xiao-li; Sun, Hong-xia; Xin, Bao-li; Tang, Xiu-xia
2012-05-01
To observe the predictability of corneal flap creation with the FEMTO LDV femtosecond laser and analyze preliminarily the factors correlating to the thickness and diameter of the flap . It was a study of serial cases. 260 eyes of 130 consecutive patients were treated with the FEMTO LDV. The eyes were assigned to two groups according to intended flap thickness, 110 µm (208 eyes) and 90 µm (52 eyes). Intended flap diameter varied from 8.5 to 9.5 mm. Difference analysis of flap diameter and intended diameter as well as flap thickness and intended thickness were made. The data was analyzed with SPSS to sum up a multiple stepwise regression formula that could express their quantitative relationship. The 90 µm flap group had a average flap thickness of (95.12 ± 7.65) µm, while for the 110 µm group the average flap thickness was (104.81 ± 3.09) µm. The difference between right and left eyes was not statistically significant (t(110 µm) = -1.223, t(90 µm) = -1.343, P > 0.05). Corneal flap thickness was inversely correlated with flap diameter (r(110 µm) = -0.143, r(90 µm) = -0.315, P < 0.05), but was not related to preoperative patient age, corneal thickness, keratometric value K or intraocular pressure (r(110 µm) = -0.160, 0.054, -0.011, -0.363; r(90 µm) = 0.024, 0.074, -0.212, -0.434, all P > 0.05). Corneal flap diameter was positively correlated with preoperative corneal keratometric value K and thickness (P < 0.001, P < 0.05). Multiple stepwise regression analysis showed flap diameter was an influencing factor for flap thickness. Preoperative corneal keratometric value K and thickness were influencing factors for flap diameter. The LASIK flap creation with the FEMTO LDV laser has relatively good predictability. Flap diameter is an influencing factor for flap thickness.
Cyclicity in Upper Mississippian Bangor Limestone, Blount County, Alabama
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bronner, R.L.
1988-01-01
The Upper Mississippian (Chesterian) Bangor Limestone in Alabama consists of a thick, complex sequence of carbonate platform deposits. A continuous core through the Bangor on Blount Mountain in north-central Alabama provides the opportunity to analyze the unit for cyclicity and to identify controls on vertical facies sequence. Lithologies from the core represent four general environments of deposition: (1) subwave-base, open marine, (2) shoal, (3) lagoon, and (4) peritidal. Analysis of the vertical sequence of lithologies in the core indicates the presence of eight large-scale cycles dominated by subtidal deposits, but defined on the basis of peritidal caps. These large-scale cyclesmore » can be subdivided into 16 small-scale cycles that may be entirely subtidal but illustrate upward shallowing followed by rapid deepening. Large-scale cycles range from 33 to 136 ft thick, averaging 68 ft; small-scale cycles range from 5 to 80 ft thick and average 34 ft. Small-scale cycles have an average duration of approximately 125,000 years, which is compatible with Milankovitch periodicity. The large-scale cycles have an average duration of approximately 250,000 years, which may simply reflect variations in amplitude of sea level fluctuation or the influence of tectonic subsidence along the southeastern margin of the North American craton.« less
NASA Astrophysics Data System (ADS)
Parker, E. Horry, Jr.; Hawman, Robert B.; Fischer, Karen M.; Wagner, Lara S.
2016-09-01
Deconvolved waveforms for two earthquakes (Mw: 6.0 and 5.8) show clear postcritical SsPmp arrivals for broadband stations deployed across the coastal plain of Georgia, allowing mapping of crustal thickness in spite of strong reverberations generated by low-velocity sediments. Precritical SsPmp arrivals are also identified. For a basement in which velocity increases linearly with depth, a bootstrapped grid search suggests an average basement velocity of 6.5 ± 0.1 km/s and basement thickness of 29.8 ± 2.0 km. Corresponding normal-incidence Moho two-way times (including sediments) are 10.6 ± 0.6 s, consistent with times for events interpreted as Moho reflections on coincident active-source reflection profiles. Modeling of an underplated mafic layer (Vp = 7.2-7.4 km/s) using travel time constraints from SsPmp data and vertical-incidence Moho reflection times yields a total basement thickness of 30-35 km and average basement velocity of 6.35-6.65 km/s for an underplate thickness of 0-15 km.
Jia, Xiansheng; Tang, Chengchun; Pan, Ruhao; Long, Yun-Ze; Gu, Changzhi; Li, Junjie
2018-05-10
Photodetection based on Two-dimensional (2D) SnS2 has attracted a growing interest due to its superiority in response rate and responsivity, but high-quality growth and high performance photodetecting of 2D SnS2still face great challenges. Here, high-quality SnS2 nanoflakes with large-size and high-production are vertically grown on Si substrate by a modified CVD method, having an average size of 30 m with different thicknesses. Then a single SnS2 nanoflake-based phototransistor was fabricated to obtain a high current on/off ratio of 107 and excellent performances in photodetection, including fast response rates, low dark current, high responsivity and detectivity. Specifically, the SnS2 nanoflakes show the thickness-dependent photodetection capability and the highest responsivity of 354.4 A W-1 is obtained at the average thickness of 100.5 nm. A sensitized process using HfO2 nanolayer can further enhance the responsivity up to 1922 A W-1. Our work provides an efficient path to select SnS2 crystal samples with the optimal thickness as promising candidates for high-performance optoelectronic applications.
Avalanche multiplication and impact ionization in amorphous selenium photoconductive target
NASA Astrophysics Data System (ADS)
Park, Wug-Dong; Tanioka, Kenkichi
2014-03-01
The avalanche multiplication factor and the hole ionization coefficient in the amorphous selenium (a-Se) high-gain avalanche rushing amorphous photoconductor (HARP) target depend on the electric field. The phenomenon of avalanche multiplication and impact ionization in the 0.4-µm-thick a-Se HARP target is investigated. The hot carrier energy in the 0.4-µm-thick a-Se HARP target increases linearly as the target voltage increases. The energy relaxation length of hot carriers in the a-Se photoconductor of the 0.4-µm-thick HARP target saturates as the electric field increases. The average energy Eav of a hot carrier and the energy relaxation length λE in the a-Se photoconductor of the 0.4-µm-thick HARP target at 1 × 108 V/m were 0.25 eV and 2.5 nm, respectively. In addition, the hole ionization coefficient β and the avalanche multiplication factor M are derived as a function of the electric field, the average energy of a hot carrier, and the impact ionization energy. The experimental hole ionization coefficient β and the avalanche multiplication factor M in the 0.4-µm-thick a-Se HARP target agree with the theoretical results.
Nordhorn, Christian; Mücke, Robert; Unocic, Kinga A.; ...
2014-08-20
In this paper, furnace cycling experiments were performed on free-standing high-velocity oxygen-fuel bond coat samples to investigate the effect of material composition, surface texture, and cycling conditions on the average stresses in the formed oxide scales after cooling. The oxide scale thicknesses were determined by SEM image analyses and information about the stresses were acquired by photo-stimulated luminescence-spectroscopy. Additionally, the scale thickness dependent stress fields were calculated in finite-element analyses including approximation functions for the surface roughness derived on the basis of profilometry data. The evolution of the average residual stress as a function of oxide scale thickness was subjectmore » to stochastic fluctuations predominantly caused by local scale spallations. In comparison to the supplemental modeling results, thermal stresses due to mismatch of thermal expansion coefficients are identified as the main contribution to the residual stresses. Finally, the theoretical results emphasize that analyses of spectroscopic data acquired for average stress investigations of alumina scales rely on detailed information about microstructural features.« less
NASA Astrophysics Data System (ADS)
Powell, C. J.; Jablonski, A.; Werner, W. S. M.; Smekal, W.
2005-01-01
We describe two NIST databases that can be used to characterize thin films from Auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS) measurements. First, the NIST Electron Effective-Attenuation-Length Database provides values of effective attenuation lengths (EALs) for user-specified materials and measurement conditions. The EALs differ from the corresponding inelastic mean free paths on account of elastic-scattering of the signal electrons. The database supplies "practical" EALs that can be used to determine overlayer-film thicknesses. Practical EALs are plotted as a function of film thickness, and an average value is shown for a user-selected thickness. The average practical EAL can be utilized as the "lambda parameter" to obtain film thicknesses from simple equations in which the effects of elastic-scattering are neglected. A single average practical EAL can generally be employed for a useful range of film thicknesses and for electron emission angles of up to about 60°. For larger emission angles, the practical EAL should be found for the particular conditions. Second, we describe a new NIST database for the Simulation of Electron Spectra for Surface Analysis (SESSA) to be released in 2004. This database provides data for many parameters needed in quantitative AES and XPS (e.g., excitation cross-sections, electron-scattering cross-sections, lineshapes, fluorescence yields, and backscattering factors). Relevant data for a user-specified experiment are automatically retrieved by a small expert system. In addition, Auger electron and photoelectron spectra can be simulated for layered samples. The simulated spectra, for layer compositions and thicknesses specified by the user, can be compared with measured spectra. The layer compositions and thicknesses can then be adjusted to find maximum consistency between simulated and measured spectra, and thus, provide more detailed characterizations of multilayer thin-film materials. SESSA can also provide practical EALs, and we compare values provided by the NIST EAL database and SESSA for hafnium dioxide. Differences of up to 10% were found for film thicknesses less than 20 Å due to the use of different physical models in each database.
Doughty, Michael J; Jonuscheit, Sven
2007-04-01
In recent years, there has been increasing interest in the characteristics of the peripheral cornea close to the limbus, in both tonometry measures and refractive surgery, but there is relatively little information on these characteristics as provided by modern day pachymetry instruments such as the Orbscan (Bausch & Lomb, Rochester, New York). The current study was therefore undertaken to assess the corneal thickness profile along the horizontal meridian by this scanning slit light method, comparing the data with that obtained with an ultrasound pachymeter. Noncontact specular microscopy was first performed on 17 adults (aged between 20 and 64 years) to check that the corneas were normal. Then, 3 assessments of the corneal thickness profile across the horizontal meridian were taken using the Orbscan II, and both the regional map data (7-mm-diameter measurement ring, 1-mm sample zones) and the point data from the numerical pachymetry output were used to extract data at specific locations nominally 0.5 mm apart. Ultrasound pachymetry (under topical anesthesia with benoxinate 0.4%) was then used to obtain thickness values at central, mid-peripheral (2.75 mm), and peripheral locations close to the limbus (4.5 mm). Specular microscopy yielded mean thickness of 0.529 +/- 0.032 mm, whereas single-point Orbscan readings at the geometric center of the cornea averaged 0.579 +/- 0.037 mm. Orbscan readings around the 7-mm-diameter measurement zone along the horizontal meridian averaged 0.681 +/- 0.034 mm (i.e., were 0.101 mm or 17.6% greater; P < 0.001). Mid-peripheral readings taken from the numerical maps at 2.5 to 3.0 mm averaged 0.645 mm (or 11% higher than central point readings), whereas peripheral readings between 4.0 and 4.5 mm averaged 0.727 mm (i.e., 26% higher than central point values). In marked contrast, ultrasound readings in the mid-periphery (2.75 mm) averaged just 0.553 mm (or 5.5% greater than the central corneal thickness [CCT]) and just 0.612 mm (i.e., 16.6% higher) in the periphery (4.5 mm). CCT profiles generated from the Orbscan numerical output across the horizontal meridian showed a predictable progressive increase in thickness from the center to the 4.5-mm location on both the temporal and nasal side. The mean differences between the Orbscan II and ultrasound pachymetry measures were thus not constant across the cornea. Without correction, these differences were close to 0.05 mm at the center but more than 0.100 mm at the peripheral sites, and proportional differences persisted after application of the default acoustic factor of 0.92 for the Orbscan readings. Orbscan II and ultrasound pachymetry measures generate a rather different profile for corneal thickness. The data from the 2 techniques should be considered as reporting different characteristics, rather than attempts being made to align Orbscan measurements to those of the ultrasound method. A single acoustic correction factor cannot be logically applied to all corneal thickness measures made with an Orbscan II.
NASA Astrophysics Data System (ADS)
Ramirez, C.; Nyblade, A.; Emry, E. L.; Julià, J.; Sun, X.; Anandakrishnan, S.; Wiens, D. A.; Aster, R. C.; Huerta, A. D.; Winberry, P.; Wilson, T.
2017-12-01
A uniform set of crustal parameters for seismic stations deployed on rock in West Antarctica and the Transantarctic Mountains (TAM) has been obtained to help elucidate similarities and differences in crustal structure within and between several tectonic blocks that make up these regions. P-wave receiver functions have been analysed using the H-κ stacking method to develop estimates of thickness and bulk Poisson's ratio for the crust, and jointly inverted with surface wave dispersion measurements to obtain depth-dependent shear wave velocity models for the crust and uppermost mantle. The results from 33 stations are reported, including three stations for which no previous results were available. The average crustal thickness is 30 ± 5 km along the TAM front, and 38 ± 2 km in the interior of the mountain range. The average Poisson's ratios for these two regions are 0.25 ± 0.03 and 0.26 ± 0.02, respectively, and they have similar average crustal Vs of 3.7 ± 0.1 km s-1. At multiple stations within the TAM, we observe evidence for mafic layering within or at the base of the crust, which may have resulted from the Ferrar magmatic event. The Ellsworth Mountains have an average crustal thickness of 37 ± 2 km, a Poisson's ratio of 0.27, and average crustal Vs of 3.7 ± 0.1 km s-1, similar to the TAM. This similarity is consistent with interpretations of the Ellsworth Mountains as a tectonically rotated TAM block. The Ross Island region has an average Moho depth of 25 ± 1 km, an average crustal Vs of 3.6 ± 0.1 km s-1 and Poisson's ratio of 0.30, consistent with the mafic Cenozoic volcanism found there and its proximity to the Terror Rift. Marie Byrd Land has an average crustal thickness of 30 ± 2 km, Poisson's ratio of 0.25 ± 0.04 and crustal Vs of 3.7 ± 0.1 km s-1. One station (SILY) in Marie Byrd Land is near an area of recent volcanism and deep (25-40 km) seismicity, and has a high Poisson's ratio, consistent with the presence of partial melt in the crust.
Thick Disks in the Hubble Space Telescope Frontier Fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elmegreen, Bruce G.; Elmegreen, Debra Meloy; Tompkins, Brittany
Thick disk evolution is studied using edge-on galaxies in two Hubble Space Telescope Frontier Field Parallels. The galaxies were separated into 72 clumpy types and 35 spiral types with bulges. Perpendicular light profiles in F435W, F606W, and F814W ( B , V , and I ) passbands were measured at 1 pixel intervals along the major axes and fitted to sech{sup 2} functions convolved with the instrument line spread function (LSF). The LSF was determined from the average point spread function of ∼20 stars in each passband and field, convolved with a line of uniform brightness to simulate disk blurring.more » A spread function for a clumpy disk was also used for comparison. The resulting scale heights were found to be proportional to galactic mass, with the average height for a 10{sup 10±0.5} M {sub ⊙} galaxy at z = 2 ± 0.5 equal to 0.63 ± 0.24 kpc. This value is probably the result of a blend between thin and thick disk components that cannot be resolved. Evidence for such two-component structure is present in an inverse correlation between height and midplane surface brightness. Models suggest that the thick disk is observed best between the clumps, and there the average scale height is 1.06 ± 0.43 kpc for the same mass and redshift. A 0.63 ± 0.68 mag V − I color differential with height is also evidence for a mixture of thin and thick components.« less
Diagnostic ability of macular ganglion cell asymmetry for glaucoma.
Hwang, Young Hoon; Ahn, Sang Il; Ko, Sung Ju
2015-11-01
Using spectral-domain optical coherence tomography (OCT), this study aims to investigate the glaucoma diagnostic ability of macular ganglion cell asymmetry analysis. A cross-sectional study was conducted. This study was performed to investigate glaucoma diagnostic ability of macular ganglion cell asymmetry analysis in eyes with various degrees of glaucoma. We enrolled 181 healthy eyes and 265 glaucomatous eyes. Glaucomatous eyes were subdivided into pre-perimetric, early, moderate and advanced-to-severe glaucoma based on visual field test results. For each eye, macular ganglion cell-inner plexiform layer (GCIPL) thickness was measured using OCT. Average GCIPL thickness, GCIPL thicknesses in superior and inferior hemispheres, absolute difference in GCIPL thickness between superior and inferior hemispheres and GCIPL asymmetry index calculated as the absolute value of log10 (inferior hemisphere thickness/superior hemisphere thickness) were analysed. Areas under the receiver operating characteristics curves (AUCs) of GCIPL parameter were calculated and compared. All of the GCIPL parameters showed good glaucoma diagnostic ability (AUCs ≥ 0.817, P < 0.01). AUCs of average, superior and inferior GCIPL thickness increased as the severity of glaucoma increased. GCIPL thickness difference and asymmetry index showed the highest AUCs in early and moderate glaucoma and lower AUCs in pre-perimetric and advanced-to-severe glaucoma. GCIPL thickness difference and asymmetry index showed better glaucoma diagnostic ability than other GCIPL parameters only in early stage of glaucoma (P < 0.05); in other stages, these parameters had similar to or worse glaucoma diagnostic ability than other GCIPL parameters. Macular ganglion cell asymmetry analysis showed good glaucoma diagnostic ability, especially in early-stage glaucoma. However, it has limited usefulness in other stages of glaucoma. © 2015 Royal Australian and New Zealand College of Ophthalmologists.
Choroidal thickness in traumatic optic neuropathy.
Lee, Ju-Yeun; Eo, Doo-Ri; Park, Kyung-Ah; Oh, Sei Yeul
2017-12-01
To examine the choroidal thickness in patients with indirect traumatic optic neuropathy (TON) Methods: Patients with unilateral traumatic optic neuropathy over a period of 4 years were included in this study. Horizontal and vertical enhanced-depth imaging (EDI) from spectral-domain optical coherence tomography (SD-OCT) scans of the fovea were obtained in patients with unilateral TON within 2 weeks of injury. The main outcome measure was the choroidal thickness at nine locations. The choroidal thickness was compared between affected and unaffected eyes in the TON group, and the mean difference in the choroidal thickness in both eyes was compared between TON and control groups. A total of 16 patients and 20 control subjects were included. The choroidal thickness at horizontal, vertical and average subfoveal, inner temporal, and outer inferior locations was significantly thicker (13-23%) in affected eyes than in unaffected fellow eyes (p = 0.042, 0.046, 0.024, 0.013, 0.018, and 0.027, respectively). The mean difference value between choroidal thickness measurements in both eyes was significantly larger in the TON group than in the control group at the horizontal, vertical and average subfoveal, inner temporal, inner nasal, inner superior, inner inferior, and outer superior locations (p = 0.001, 0.011, <0.001, 0.001, 0.033, 0.014, 0.011, and 0.014, respectively). The choroidal thickness at subfoveal locations showed no statistical difference between TON and control eyes (p > 0.05). Eyes affected by TON showed a regionally thicker choroid than unaffected fellow eye. This thick choroid might be due to impaired blood circulation and vascular remodeling of the optic nerve head and choroid. These results help to better understand the pathophysiology of TON.