Sample records for avoid power outages

  1. Effect of global warming on willingness to pay for uninterrupted electricity supply in European nations

    NASA Astrophysics Data System (ADS)

    Cohen, Jed; Moeltner, Klaus; Reichl, Johannes; Schmidthaler, Michael

    2018-01-01

    Predicted changes in temperature and other weather events may damage the electricity grid and cause power outages. Understanding the costs of power outages and how these costs change over time with global warming can inform outage-mitigation-investment decisions. Here we show that across 19 EU nations the value of uninterrupted electricity supply is strongly related to local temperatures, and will increase as the climate warms. Bayesian hierarchical modelling of data from a choice experiment and respondent-specific temperature measures reveals estimates of willingness to pay (WTP) to avoid an hour of power outage between €0.32 and €1.86 per household. WTP varies on the basis of season and is heterogeneous between European nations. Winter outages currently cause larger per household welfare losses than summer outages per hour of outage. However, this dynamic will begin to shift under plausible future climates, with summer outages becoming substantially more costly and winter outages becoming slightly less costly on a per-household, per-hour basis.

  2. Development of Methodologies for Technology Deployment for Advanced Outage Control Centers that Improve Outage Coordination, Problem Resolution and Outage Risk Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shawn St. Germain; Ronald Farris; Heather Medeman

    2013-09-01

    This research effort is a part of the Light-Water Reactor Sustainability (LWRS) Program, which is a research and development (R&D) program sponsored by Department of Energy (DOE) and performed in close collaboration with industry R&D programs that provides the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants. The LWRS program serves to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The long term viability of existing nuclear power plants in the U.S.more » will depend upon maintaining high capacity factors, avoiding nuclear safety issues and reducing operating costs. The slow progress in the construction on new nuclear power plants has placed in increased importance on maintaining the output of the current fleet of nuclear power plants. Recently expanded natural gas production has placed increased economic pressure on nuclear power plants due to lower cost competition. Until recently, power uprate projects had steadily increased the total output of the U.S. nuclear fleet. Errors made during power plant upgrade projects have now removed three nuclear power plants from the U.S. fleet and economic considerations have caused the permanent shutdown of a fourth plant. Additionally, several utilities have cancelled power uprate projects citing economic concerns. For the past several years net electrical generation from U.S. nuclear power plants has been declining. One of few remaining areas where significant improvements in plant capacity factors can be made is in minimizing the duration of refueling outages. Managing nuclear power plant outages is a complex and difficult task. Due to the large number of complex tasks and the uncertainty that accompanies them, outage durations routinely exceed the planned duration. The ability to complete an outage on or near schedule depends upon the performance of the outage management organization. During an outage, the outage control center (OCC) is the temporary command center for outage managers and provides several critical functions for the successful execution of the outage schedule. Essentially, the OCC functions to facilitate information inflow, assist outage management in processing information and to facilitate the dissemination of information to stakeholders. Currently, outage management activities primarily rely on telephone communication, face to face reports of status and periodic briefings in the OCC. Much of the information displayed in OCCs is static and out of date requiring an evaluation to determine if it is still valid. Several advanced communication and collaboration technologies have shown promise for facilitating the information flow into, across and out of the OCC. Additionally, advances in the areas of mobile worker technologies, computer based procedures and electronic work packages can be leveraged to improve the availability of real time status to outage managers.« less

  3. Synergistic Use of Nighttime Satellite Data, Electric Utility Infrastructure, and Ambient Population to Improve Power Outage Detections in Urban Areas

    NASA Technical Reports Server (NTRS)

    Cole, Tony A.; Wanik, David W.; Molthan, Andrew L.; Roman, Miguel O.; Griffin, Robert E.

    2017-01-01

    Natural and anthropogenic hazards are frequently responsible for disaster events, leading to damaged physical infrastructure, which can result in loss of electrical power for affected locations. Remotely-sensed, nighttime satellite imagery from the Suomi National Polar-orbiting Partnership (Suomi-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) can monitor power outages in disaster-affected areas through the identification of missing city lights. When combined with locally-relevant geospatial information, these observations can be used to estimate power outages, defined as geographic locations requiring manual intervention to restore power. In this study, we produced a power outage product based on Suomi-NPP VIIRS DNB observations to estimate power outages following Hurricane Sandy in 2012. This product, combined with known power outage data and ambient population estimates, was then used to predict power outages in a layered, feedforward neural network model. We believe this is the first attempt to synergistically combine such data sources to quantitatively estimate power outages. The VIIRS DNB power outage product was able to identify initial loss of light following Hurricane Sandy, as well as the gradual restoration of electrical power. The neural network model predicted power outages with reasonable spatial accuracy, achieving Pearson coefficients (r) between 0.48 and 0.58 across all folds. Our results show promise for producing a continental United States (CONUS)- or global-scale power outage monitoring network using satellite imagery and locally-relevant geospatial data.

  4. Hurricane Isaac: A Longitudinal Analysis of Storm Characteristics and Power Outage Risk.

    PubMed

    Tonn, Gina L; Guikema, Seth D; Ferreira, Celso M; Quiring, Steven M

    2016-10-01

    In August 2012, Hurricane Isaac, a Category 1 hurricane at landfall, caused extensive power outages in Louisiana. The storm brought high winds, storm surge, and flooding to Louisiana, and power outages were widespread and prolonged. Hourly power outage data for the state of Louisiana were collected during the storm and analyzed. This analysis included correlation of hourly power outage figures by zip code with storm conditions including wind, rainfall, and storm surge using a nonparametric ensemble data mining approach. Results were analyzed to understand how correlation of power outages with storm conditions differed geographically within the state. This analysis provided insight on how rainfall and storm surge, along with wind, contribute to power outages in hurricanes. By conducting a longitudinal study of outages at the zip code level, we were able to gain insight into the causal drivers of power outages during hurricanes. Our analysis showed that the statistical importance of storm characteristic covariates to power outages varies geographically. For Hurricane Isaac, wind speed, precipitation, and previous outages generally had high importance, whereas storm surge had lower importance, even in zip codes that experienced significant surge. The results of this analysis can inform the development of power outage forecasting models, which often focus strictly on wind-related covariates. Our study of Hurricane Isaac indicates that inclusion of other covariates, particularly precipitation, may improve model accuracy and robustness across a range of storm conditions and geography. © 2016 Society for Risk Analysis.

  5. ALARA and planning of interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocaboy, A.

    1995-03-01

    The implementation of ALARA programs implies integration of radiation protection criterion at all stages of outage management. Within the framework of its ALARA policy, Electricide de France (EDF) has given an incentive to all of its nuclear power plants to develop {open_quotes}good practices{close_quotes} in this domain, and to exchange their experience by the way of a national feed back file. Among the developments in the field of outage organization, some plants have focused on the planning stage of activities because of its influence on the radiological conditions of interventions and on the good succession of tasks within the radiological controlledmore » areas. This paper presents the experience of Chinon nuclear power plant. At Chinon, we are pursuing this goal through careful outage planning. We want the ALARA program during outages to be part of the overall maintenance task planning. This planning includes the provision of the availability of every safety-related component, and of the variations of water levels in hthereactor and steam generators to take advantage of the shield created by the water. We have developed a computerized data base with the exact position of all the components in the reactor building in order to avoid unnecessary interactions between different tasks performed in the same room. A common language between Operation and Maintenance had been established over the past years, using {open_quotes}Milestones and Corridors{close_quotes}. A real time dose rate counting system enables the Radiation Protection (RP) Department to do an accurate and efficient follow up during the outage for all the {open_quotes}ALARA{close_quotes} maintenance tasks.« less

  6. Estimating Power Outage Cost based on a Survey for Industrial Customers

    NASA Astrophysics Data System (ADS)

    Yoshida, Yoshikuni; Matsuhashi, Ryuji

    A survey was conducted on power outage cost for industrial customers. 5139 factories, which are designated energy management factories in Japan, answered their power consumption and the loss of production value due to the power outage in an hour in summer weekday. The median of unit cost of power outage of whole sectors is estimated as 672 yen/kWh. The sector of services for amusement and hobbies and the sector of manufacture of information and communication electronics equipment relatively have higher unit cost of power outage. Direct damage cost from power outage in whole sectors reaches 77 billion yen. Then utilizing input-output analysis, we estimated indirect damage cost that is caused by the repercussion of production halt. Indirect damage cost in whole sectors reaches 91 billion yen. The sector of wholesale and retail trade has the largest direct damage cost. The sector of manufacture of transportation equipment has the largest indirect damage cost.

  7. A Model for QoS – Aware Wireless Communication in Hospitals

    PubMed Central

    Alavikia, Zahra; Khadivi, Pejman; Hashemi, Masoud Reza

    2012-01-01

    In the recent decade, research regarding wireless applications in electronic health (e-Health) services has been increasing. The main benefits of using wireless technologies in e-Health applications are simple communications, fast delivery of medical information, reducing treatment cost and also reducing the medical workers’ error rate. However, using wireless communications in sensitive healthcare environment raises electromagnetic interference (EMI). One of the most effective methods to avoid the EMI problem is power management. To this end, some of methods have been proposed in the literature to reduce EMI effects in health care environments. However, using these methods may result in nonaccurate interference avoidance and also may increase network complexity. To overcome these problems, we introduce two approaches based on per-user location and hospital sectoring for power management in sensitive healthcare environments. Although reducing transmission power could avoid EMI, it causes a number of successful message deliveries to the access point to decrease and, hence, the quality of service requirements cannot be meet. In this paper, we propose the use of relays for decreasing the probability of outage in the aforementioned scenario. Relay placement is the main factor to enjoy the usefulness of relay station benefits in the network and, therefore, we use the genetic algorithm to compute the optimum positions of a fixed number of relays. We have considered delay and maximum blind point coverage as two main criteria in relay station problem. The performance of the proposed method in outage reduction is investigated through simulations. PMID:23493832

  8. A Model for QoS - Aware Wireless Communication in Hospitals.

    PubMed

    Alavikia, Zahra; Khadivi, Pejman; Hashemi, Masoud Reza

    2012-01-01

    In the recent decade, research regarding wireless applications in electronic health (e-Health) services has been increasing. The main benefits of using wireless technologies in e-Health applications are simple communications, fast delivery of medical information, reducing treatment cost and also reducing the medical workers' error rate. However, using wireless communications in sensitive healthcare environment raises electromagnetic interference (EMI). One of the most effective methods to avoid the EMI problem is power management. To this end, some of methods have been proposed in the literature to reduce EMI effects in health care environments. However, using these methods may result in nonaccurate interference avoidance and also may increase network complexity. To overcome these problems, we introduce two approaches based on per-user location and hospital sectoring for power management in sensitive healthcare environments. Although reducing transmission power could avoid EMI, it causes a number of successful message deliveries to the access point to decrease and, hence, the quality of service requirements cannot be meet. In this paper, we propose the use of relays for decreasing the probability of outage in the aforementioned scenario. Relay placement is the main factor to enjoy the usefulness of relay station benefits in the network and, therefore, we use the genetic algorithm to compute the optimum positions of a fixed number of relays. We have considered delay and maximum blind point coverage as two main criteria in relay station problem. The performance of the proposed method in outage reduction is investigated through simulations.

  9. Synthesis of power plant outage schedules. Final technical report, April 1995-January 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, D.R.

    This document provides a report on the creation of domain theories in the power plant outage domain. These were developed in conjunction with the creation of a demonstration system of advanced scheduling technology for the outage problem. In 1994 personnel from Rome Laboratory (RL), Kaman Science (KS), Kestrel Institute, and the Electric Power Research Institute (EPRI) began a joint project to develop scheduling tools for power plant outage activities. This report describes our support for this joint effort. The project uses KIDS (Kestrel Interactive Development System) to generate schedulers from formal specifications of the power plant domain outage activities.

  10. The cost of power outages in the business and public sectors in Israel: Revealed preference vs. subjective evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beenstock, M.; Goldin, E.; Haitovsky, Y.

    1997-05-01

    The economic cost of power outages is a central parameter in the cost-benefit analysis of electric power reliability and the design of electric power systems. The authors present a new methodology for estimating the cost of power outages in the business and public sections and illustrate with data for Israel. The methodology is based on the principle of revealed preference, the cost of an outage may be inferred from the actions taken by consumers to mitigate losses induced by unsupplied electricity. If outages impose costs on businesses, managers are likely to invest in back-up power to mitigate the losses thatmore » are incurred when electricity is not supplied. Investment in back-up generators may then be used to impute the mitigated and unmitigated damage from outages. 12 refs., 3 figs., 7 tabs.« less

  11. Does NASA SMAP Improve the Accuracy of Power Outage Models?

    NASA Astrophysics Data System (ADS)

    Quiring, S. M.; McRoberts, D. B.; Toy, B.; Alvarado, B.

    2016-12-01

    Electric power utilities make critical decisions in the days prior to hurricane landfall that are primarily based on the estimated impact to their service area. For example, utilities must determine how many repair crews to request from other utilities, the amount of material and equipment they will need to make repairs, and where in their geographically expansive service area to station crews and materials. Accurate forecasts of the impact of an approaching hurricane within their service area are critical for utilities in balancing the costs and benefits of different levels of resources. The Hurricane Outage Prediction Model (HOPM) are a family of statistical models that utilize predictions of tropical cyclone windspeed and duration of strong winds, along with power system and environmental variables (e.g., soil moisture, long-term precipitation), to forecast the number and location of power outages. This project assesses whether using NASA SMAP soil moisture improves the accuracy of power outage forecasts as compared to using model-derived soil moisture from NLDAS-2. A sensitivity analysis is employed since there have been very few tropical cyclones making landfall in the United States since SMAP was launched. The HOPM is used to predict power outages for 13 historical tropical cyclones and the model is run using twice, once with NLDAS soil moisture and once with SMAP soil moisture. Our results demonstrate that using SMAP soil moisture can have a significant impact on power outage predictions. SMAP has the potential to enhance the accuracy of power outage forecasts. Improved outage forecasts reduce the duration of power outages which reduces economic losses and accelerates recovery.

  12. Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices That Require Electricity

    MedlinePlus

    ... Handle Power Outages for Medical Devices that Require Electricity Center for De CDRH vices and Rad lth ... Handle Power Outages for Medical Devices that Require Electricity As a home medical device user, it is ...

  13. 2006 Update of Business Downtime Costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinrichs, Mr. Doug; Goggin, Mr. Michael

    2007-01-01

    The objective of this paper is to assess the downtime cost of power outages to businesses in the commercial and industrial sectors, updating and improving upon studies that have already been published on this subject. The goal is to produce a study that, relative to existing studies, (1) applies to a wider set of business types (2) reflects more current downtime costs, (3) accounts for the time duration factor of power outages, and (4) includes data on the costs imposed by real outages in a well-defined market. This study examines power outage costs in 11 commercial subsectors and 5 industrialmore » subsectors, using data on downtime costs that was collected in the 1990's. This study also assesses power outage costs for power outages of 20 minutes, 1 hour, and 4 hours duration. Finally, this study incorporates data on the costs of real power outages for two business subsectors. However, the current limited state of data availability on the topic of downtime costs means there is room to improve upon this study. Useful next steps would be to generate more recent data on downtime costs, data that covers outages shorter than 20 minutes duration and longer than 4 hours duration, and more data that is based on the costs caused by real-world outages. Nevertheless, with the limited data that is currently available, this study is able to generate a clear and detailed picture of the downtime costs that are faced by different types of businesses.« less

  14. Effects of Phasor Measurement Uncertainty on Power Line Outage Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chen; Wang, Jianhui; Zhu, Hao

    2014-12-01

    Phasor measurement unit (PMU) technology provides an effective tool to enhance the wide-area monitoring systems (WAMSs) in power grids. Although extensive studies have been conducted to develop several PMU applications in power systems (e.g., state estimation, oscillation detection and control, voltage stability analysis, and line outage detection), the uncertainty aspects of PMUs have not been adequately investigated. This paper focuses on quantifying the impact of PMU uncertainty on power line outage detection and identification, in which a limited number of PMUs installed at a subset of buses are utilized to detect and identify the line outage events. Specifically, the linemore » outage detection problem is formulated as a multi-hypothesis test, and a general Bayesian criterion is used for the detection procedure, in which the PMU uncertainty is analytically characterized. We further apply the minimum detection error criterion for the multi-hypothesis test and derive the expected detection error probability in terms of PMU uncertainty. The framework proposed provides fundamental guidance for quantifying the effects of PMU uncertainty on power line outage detection. Case studies are provided to validate our analysis and show how PMU uncertainty influences power line outage detection.« less

  15. As assessment of power system vulnerability to release of carbon fibers during commercial aviation accidents

    NASA Technical Reports Server (NTRS)

    Larocque, G. R.

    1980-01-01

    The vulnerability of a power distribution system in Bedford and Lexington, Massachusetts to power outages as a result of exposure to carbon fibers released in a commercial aviation accident in 1993 was examined. Possible crash scenarios at Logan Airport based on current operational data and estimated carbon fiber usage levels were used to predict exposure levels and occurrence probabilities. The analysis predicts a mean time between carbon fiber induced power outages of 2300 years with an expected annual consequence of 0.7 persons losing power. In comparison to historical outage data for the system, this represents a 0.007% increase in outage rate and 0.07% increase in consequence.

  16. Economic costs of electrical system instability and power outages caused by snakes on the Island of Guam

    USGS Publications Warehouse

    Fritts, T.H.

    2002-01-01

    The Brown Tree Snake, Boiga irregularis, is an introduced species on Guam where it causes frequent electrical power outages. The snake's high abundance, its propensity for climbing, and use of disturbed habitats all contribute to interruption of Guam's electrical service and the activities that depend on electrical power. Snakes have caused more than 1600 power outages in the 20-yr period of 1978-1997 and most recently nearly 200 outages per year. Single outages spanning the entire island and lasting 8 or more hours are estimated to cost in excess of $3,000,000 in lost productivity, but the costs of outages that involve only parts of the island or those of shorter durations are more difficult to quantify. Costs to the island's economy have exceeded $4.5 M per year over a 7-yr period without considering repair costs, damage to electrical equipment, and lost revenues. Snakes pose the greatest problem on high voltage transmission lines, on transformers, and inside electrical substations.

  17. Comparison and validation of statistical methods for predicting power outage durations in the event of hurricanes.

    PubMed

    Nateghi, Roshanak; Guikema, Seth D; Quiring, Steven M

    2011-12-01

    This article compares statistical methods for modeling power outage durations during hurricanes and examines the predictive accuracy of these methods. Being able to make accurate predictions of power outage durations is valuable because the information can be used by utility companies to plan their restoration efforts more efficiently. This information can also help inform customers and public agencies of the expected outage times, enabling better collective response planning, and coordination of restoration efforts for other critical infrastructures that depend on electricity. In the long run, outage duration estimates for future storm scenarios may help utilities and public agencies better allocate risk management resources to balance the disruption from hurricanes with the cost of hardening power systems. We compare the out-of-sample predictive accuracy of five distinct statistical models for estimating power outage duration times caused by Hurricane Ivan in 2004. The methods compared include both regression models (accelerated failure time (AFT) and Cox proportional hazard models (Cox PH)) and data mining techniques (regression trees, Bayesian additive regression trees (BART), and multivariate additive regression splines). We then validate our models against two other hurricanes. Our results indicate that BART yields the best prediction accuracy and that it is possible to predict outage durations with reasonable accuracy. © 2011 Society for Risk Analysis.

  18. Verification and Enhancement of VIIRS Day-Night Band Power Outage Detection Product

    NASA Astrophysics Data System (ADS)

    Burke, A.; Schultz, L. A.; Omitaomu, O.; Molthan, A.; Cole, T.; Griffin, R.

    2017-12-01

    The NASA SPoRT (Short-term Prediction Research and Transition) Center has collaborated with scientists at NASA Goddard Space Flight Center to create a power outage detection product from radiance data obtained by the VIIRS (Visible Infrared Imaging Radiometer Suite) sensor aboard the Suomi-NPP satellite. This product uses a composite of pre-event radiance values from the VIIRS Day-Night Band to establish a baseline of "normal" nighttime lights for a study area. Then, after a severe weather event or other disaster, post-event images are compared to the composite to generate a percent-of-normal radiance product to identify areas that are experiencing outages and to aid in disaster response and monitor recovery. This project will use ground-truth county-level outage data provided by Oak Ridge National Laboratory (ORNL) in order validate the product and to establish a percent-of-normal threshold for identifying power outages. Once a threshold is found, ORNL's LandScan Global population data will be combined with the product to estimate how many electrical customers are being affected by power outages after a disaster. Two case studies will be explored to examine power outage recovery after severe weather events, including Hurricane Matthew from 2016 and the Washington D.C. Derecho event of 2012.

  19. Power Outages

    MedlinePlus

    ... of the items you need that rely on electricity. Talk to your medical provider about a power outage plan for medical devices powered by electricity and refrigerated medicines. Find out how long medication ...

  20. Predicting Power Outages Using Multi-Model Ensemble Forecasts

    NASA Astrophysics Data System (ADS)

    Cerrai, D.; Anagnostou, E. N.; Yang, J.; Astitha, M.

    2017-12-01

    Power outages affect every year millions of people in the United States, affecting the economy and conditioning the everyday life. An Outage Prediction Model (OPM) has been developed at the University of Connecticut for helping utilities to quickly restore outages and to limit their adverse consequences on the population. The OPM, operational since 2015, combines several non-parametric machine learning (ML) models that use historical weather storm simulations and high-resolution weather forecasts, satellite remote sensing data, and infrastructure and land cover data to predict the number and spatial distribution of power outages. A new methodology, developed for improving the outage model performances by combining weather- and soil-related variables using three different weather models (WRF 3.7, WRF 3.8 and RAMS/ICLAMS), will be presented in this study. First, we will present a performance evaluation of each model variable, by comparing historical weather analyses with station data or reanalysis over the entire storm data set. Hence, each variable of the new outage model version is extracted from the best performing weather model for that variable, and sensitivity tests are performed for investigating the most efficient variable combination for outage prediction purposes. Despite that the final variables combination is extracted from different weather models, this ensemble based on multi-weather forcing and multi-statistical model power outage prediction outperforms the currently operational OPM version that is based on a single weather forcing variable (WRF 3.7), because each model component is the closest to the actual atmospheric state.

  1. Economic costs of electrical system instability and power outages caused by snakes on the Island of Guam

    USGS Publications Warehouse

    Fritts, T.H.

    2002-01-01

    The Brown Tree Snake, Boiga irregularis, is an introduced species on Guam where it causes frequent electrical power outages. The snake's high abundance, its propensity for climbing, and use of disturbed habitats all contribute to interruption of Guam's electrical service and the activities that depend on electrical power. Snakes have caused more than 1600 power outages in the 20-yr period of 1978–1997 and most recently nearly 200 outages per year. Single outages spanning the entire island and lasting 8 or more hours are estimated to cost in excess of $3,000,000 in lost productivity, but the costs of outages that involve only parts of the island or those of shorter durations are more difficult to quantify. Costs to the island's economy have exceeded $4.5 M $4.5M"> per year over a 7-yr period without considering repair costs, damage to electrical equipment, and lost revenues. Snakes pose the greatest problem on high voltage transmission lines, on transformers, and inside electrical substations.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garlapati, Shravan K; Kuruganti, Phani Teja; Buehrer, Richard M

    The deployment of advanced metering infrastructure by the electric utilities poses unique communication challenges, particularly as the number of meters per aggregator increases. During a power outage, a smart meter tries to report it instantaneously to the electric utility. In a densely populated residential/industrial locality, it is possible that a large number of smart meters simultaneously try to get access to the communication network to report the power outage. If the number of smart meters is very high of the order of tens of thousands (metropolitan areas), the power outage data flooding can lead to Random Access CHannel (RACH) congestion.more » Several utilities are considering the use of cellular network for smart meter communications. In 3G/4G cellular networks, RACH congestion not only leads to collisions, retransmissions and increased RACH delays, but also has the potential to disrupt the dedicated traffic flow by increasing the interference levels (3G CDMA). In order to overcome this problem, in this paper we propose a Time Hierarchical Scheme (THS) that reduces the intensity of power outage data flooding and power outage reporting delay by 6/7th, and 17/18th when compared to their respective values without THS. Also, we propose an Optimum Transmission Rate Adaptive (OTRA) MAC to optimize the latency in power outage data collection. The analysis and simulation results presented in this paper show that both the OTRA and THS features of the proposed MAC results in a Power Outage Data Collection Latency (PODCL) that is 1/10th of the 4G LTE PODCL.« less

  3. New York Solar Smart DG Hub-Resilient Solar Project: Economic and Resiliency Impact of PV and Storage on New York Critical Infrastructure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Kate; Burman, Kari; Simpkins, Travis

    Resilient PV, which is solar paired with storage ('solar-plus-storage'), provides value both during normal grid operation and power outages as opposed to traditional solar PV, which functions only when the electric grid is operating. During normal grid operations, resilient PV systems help host sites generate revenue and/or reduce electricity bill charges. During grid outages, resilient PV provides critical emergency power that can help people in need and ease demand on emergency fuel supplies. The combination of grid interruptions during recent storms, the proliferation of solar PV, and the growing deployment of battery storage technologies has generated significant interest in usingmore » these assets for both economic and resiliency benefits. This report analyzes the technical and economic viability for resilient PV on three critical infrastructure sites in New York City (NYC): a school that is part of a coastal storm shelter system, a fire station, and a NYCHA senior center that serves as a cooling center during heat emergencies. This analysis differs from previous solar-plus-storage studies by placing a monetary value on resiliency and thus, in essence, modeling a new revenue stream for the avoided cost of a power outage. Analysis results show that resilient PV is economically viable for NYC's critical infrastructure and that it may be similarly beneficial to other commercial buildings across the city. This report will help city building owners, managers, and policymakers better understand the economic and resiliency benefits of resilient PV. As NYC fortifies its building stock against future storms of increasing severity, resilient PV can play an important role in disaster response and recovery while also supporting city greenhouse gas emission reduction targets and relieving stress to the electric grid from growing power demands.« less

  4. The impact of a large-scale power outage on hemodialysis center operations.

    PubMed

    Abir, Mahshid; Jan, Sophia; Jubelt, Lindsay; Merchant, Raina M; Lurie, Nicole

    2013-12-01

    On June 29, 2012, mid-Atlantic storms resulted in a large-scale power outage affecting up to three million people across multiple (US) states. Hemodialysis centers are dependent on electricity to provide dialysis care to end-stage renal disease patients. The objective of this study was to determine how the power outage impacted operations in a sample of hemodialysis centers in the impacted regions. The sample consisted of all hemodialysis centers located in the District of Columbia and a total of five counties with the largest power losses in West Virginia, Virginia, and Maryland. A semi-structured interview guide was developed, and the charge nurse or supervisor in each facility was interviewed. The survey questions addressed whether their centers lost power, if so, for how long, where their patients received dialysis, whether their centers had backup generators, and if so, whether they had any problems operating them, and whether their center received patients from other centers if they had power. Calls were placed to 90 dialysis centers in the sampled areas and a 90% response rate was achieved. Overall, hemodialysis operations at approximately 30% (n = 24) of the centers queried were impacted by the power outage. Of the 36 centers that lost power, 31% (n = 11) referred their patients to other dialysis centers, 22% (n = 8) accommodated their patients during a later shift or on a different day; the rest of the centers either experienced brief power outages that did not affect operations or experienced a power outage on days that the center is usually closed. Some centers in the study cohort reported receiving patients from other centers for dialysis 33% (n = 27). Thirty-two percent (n = 26) of the centers queried had backup generators on site. Eleven percent (n = 4) of the centers experiencing power outages reported that backup generators were brought in by their parent companies. Comprehensive emergency planning for dialysis centers should include provisions for having backup generators on site, having plans in place for the timely delivery of a generator during a power outage, or having predesignated backup dialysis centers for patients to receive dialysis during emergencies. Most dialysis centers surveyed in this study were able to sustain continuity of care by implementing such pre-existing emergency plans.

  5. Power Allocation and Outage Probability Analysis for SDN-based Radio Access Networks

    NASA Astrophysics Data System (ADS)

    Zhao, Yongxu; Chen, Yueyun; Mai, Zhiyuan

    2018-01-01

    In this paper, performance of Access network Architecture based SDN (Software Defined Network) is analyzed with respect to the power allocation issue. A power allocation scheme PSO-PA (Particle Swarm Optimization-power allocation) algorithm is proposed, the proposed scheme is subjected to constant total power with the objective of minimizing system outage probability. The entire access network resource configuration is controlled by the SDN controller, then it sends the optimized power distribution factor to the base station source node (SN) and the relay node (RN). Simulation results show that the proposed scheme reduces the system outage probability at a low complexity.

  6. Seasonal and Local Characteristics of Lightning Outages of Power Distribution Lines in Hokuriku Area

    NASA Astrophysics Data System (ADS)

    Sugimoto, Hitoshi; Shimasaki, Katsuhiko

    The proportion of the lightning outages in all outages on Japanese 6.6kV distribution lines is high with approximately 20 percent, and then lightning protections are very important for supply reliability of 6.6kV lines. It is effective for the lightning performance to apply countermeasures in order of the area where a large number of the lightning outages occur. Winter lightning occurs in Hokuriku area, therefore it is also important to understand the seasonal characteristics of the lightning outages. In summer 70 percent of the lightning outages on distribution lines in Hokuriku area were due to sparkover, such as power wire breakings and failures of pole-mounted transformers. However, in winter almost half of lightning-damaged equipments were surge arrester failures. The number of the lightning outages per lightning strokes detected by the lightning location system (LLS) in winter was 4.4 times larger than that in summer. The authors have presumed the occurrence of lightning outages from lightning stroke density, 50% value of lightning current and installation rate of lightning protection equipments and overhead ground wire by multiple regression analysis. The presumed results suggest the local difference in the lightning outages.

  7. Ensuring reliability in expansion schemes.

    PubMed

    Kamal-Uddin, Abu Sayed; Williams, Donald Leigh

    2005-01-01

    Existing electricity power supplies must serve, or be adapted to serve, the expansion of hospital buildings. With the existing power supply assets of many hospitals being up to 20 years old, assessing the security and reliability of the power system must be given appropriate priority to avoid unplanned outages due to overloads and equipment failures. It is imperative that adequate contingency is planned for essential and non-essential electricity circuits. This article describes the methodology undertaken, and the subsequent recommendations that were made, when evaluating the security and reliability of electricity power supplies to a number of major London hospitals. The methodology described aligns with the latest issue of NHS Estates HTM 2011 'Primary Electrical Infrastructure Emergency Electrical Services Design Guidance' (to which ERA Technology has contributed).

  8. Enhanced outage prediction modeling for strong extratropical storms and hurricanes in the Northeastern United States

    NASA Astrophysics Data System (ADS)

    Cerrai, D.; Anagnostou, E. N.; Wanik, D. W.; Bhuiyan, M. A. E.; Zhang, X.; Yang, J.; Astitha, M.; Frediani, M. E.; Schwartz, C. S.; Pardakhti, M.

    2016-12-01

    The overwhelming majority of human activities need reliable electric power. Severe weather events can cause power outages, resulting in substantial economic losses and a temporary worsening of living conditions. Accurate prediction of these events and the communication of forecasted impacts to the affected utilities is necessary for efficient emergency preparedness and mitigation. The University of Connecticut Outage Prediction Model (OPM) uses regression tree models, high-resolution weather reanalysis and real-time weather forecasts (WRF and NCAR ensemble), airport station data, vegetation and electric grid characteristics and historical outage data to forecast the number and spatial distribution of outages in the power distribution grid located within dense vegetation. Recent OPM improvements consist of improved storm classification and addition of new predictive weather-related variables and are demonstrated using a leave-one-storm-out cross-validation based on 130 severe extratropical storms and two hurricanes (Sandy and Irene) in the Northeast US. We show that it is possible to predict the number of trouble spots causing outages in the electric grid with a median absolute percentage error as low as 27% for some storm types, and at most around 40%, in a scale that varies between four orders of magnitude, from few outages to tens of thousands. This outage information can be communicated to the electric utility to manage allocation of crews and equipment and minimize the recovery time for an upcoming storm hazard.

  9. 40 CFR 52.145 - Visibility protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... limitation in paragraph (d)(2) of this section and shall submit a follow-up written report within 30 days of... periodic reports of compliance with the emission limitation in paragraph (d)(2) of this section which shall... for the control system outage. The report also shall describe the actions taken to avoid the outage...

  10. Verification and Enhancement of VIIRS Day-Night Band (DNB) Power Outage Detection Product

    NASA Technical Reports Server (NTRS)

    Burke, Angela; Schultz, Lori A.; Omitaomu, Olufemi; Molthan, Andrew L.; Cole, Tony; Griffin, Robert

    2017-01-01

    This case study of Hurricane Matthew (October 2016) uses the NASA Short-Term Prediction Research and Transition (SPoRT) Center DNB power outage product (using GSFC VIIRS DNB preliminary Black Marble product, Roman et al.. 2017) and 2013 LandScan Global population data to look for correlations between the post-event %-of-normal radiance and the utility company-reported outage numbers (obtained from EAGLE-1).

  11. Hybrid Cascading Outage Analysis of Extreme Events with Optimized Corrective Actions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vallem, Mallikarjuna R.; Vyakaranam, Bharat GNVSR; Holzer, Jesse T.

    2017-10-19

    Power system are vulnerable to extreme contingencies (like an outage of a major generating substation) that can cause significant generation and load loss and can lead to further cascading outages of other transmission facilities and generators in the system. Some cascading outages are seen within minutes following a major contingency, which may not be captured exclusively using the dynamic simulation of the power system. The utilities plan for contingencies either based on dynamic or steady state analysis separately which may not accurately capture the impact of one process on the other. We address this gap in cascading outage analysis bymore » developing Dynamic Contingency Analysis Tool (DCAT) that can analyze hybrid dynamic and steady state behavior of the power system, including protection system models in dynamic simulations, and simulating corrective actions in post-transient steady state conditions. One of the important implemented steady state processes is to mimic operator corrective actions to mitigate aggravated states caused by dynamic cascading. This paper presents an Optimal Power Flow (OPF) based formulation for selecting corrective actions that utility operators can take during major contingency and thus automate the hybrid dynamic-steady state cascading outage process. The improved DCAT framework with OPF based corrective actions is demonstrated on IEEE 300 bus test system.« less

  12. Assessment of Critical Events Corridors through Multivariate Cascading Outages Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, Yuri V.; Samaan, Nader A.; Diao, Ruisheng

    2011-10-17

    Massive blackouts of electrical power systems in North America over the past decade has focused increasing attention upon ways to identify and simulate network events that may potentially lead to widespread network collapse. This paper summarizes a method to simulate power-system vulnerability to cascading failures to a supplied set of initiating events synonymously termed as Extreme Events. The implemented simulation method is currently confined to simulating steady state power-system response to a set of extreme events. The outlined method of simulation is meant to augment and provide a new insight into bulk power transmission network planning that at present remainsmore » mainly confined to maintaining power system security for single and double component outages under a number of projected future network operating conditions. Although one of the aims of this paper is to demonstrate the feasibility of simulating network vulnerability to cascading outages, a more important goal has been to determine vulnerable parts of the network that may potentially be strengthened in practice so as to mitigate system susceptibility to cascading failures. This paper proposes to demonstrate a systematic approach to analyze extreme events and identify vulnerable system elements that may be contributing to cascading outages. The hypothesis of critical events corridors is proposed to represent repeating sequential outages that can occur in the system for multiple initiating events. The new concept helps to identify system reinforcements that planners could engineer in order to 'break' the critical events sequences and therefore lessen the likelihood of cascading outages. This hypothesis has been successfully validated with a California power system model.« less

  13. Lights out: Impact of the August 2003 power outage on mortality in New York, NY

    PubMed Central

    Anderson, G. Brooke; Bell, Michelle L.

    2012-01-01

    Background Little is known about how power outages affect health. We investigated mortality effects of the largest US blackout to date, August 14–15, 2003 in New York, NY. Methods We estimated mortality risk in New York, NY, using a generalized linear model with data from 1987–2005. We incorporated possible confounders, including weather and long-term and seasonal mortality trends. Results During the blackout, mortality increased for accidental deaths (122% [95% confidence interval = 28%–287%]) and non-accidental (i.e., disease-related) deaths (25% [12%–41%]), resulting in approximately 90 excess deaths. Increased mortality was not from deaths being advanced by a few days; rather, mortality risk remained slightly elevated through August 2003. Discussion To our knowledge, this is the first analysis of power outages and non-accidental mortality. Understanding the impact of power outages on human health is relevant, given that increased energy demand and climate change are likely to put added strain on power grids. PMID:22252408

  14. Designing an Alternate Mission Operations Control Room

    NASA Technical Reports Server (NTRS)

    Montgomery, Patty; Reeves, A. Scott

    2014-01-01

    The Huntsville Operations Support Center (HOSC) is a multi-project facility that is responsible for 24x7 real-time International Space Station (ISS) payload operations management, integration, and control and has the capability to support small satellite projects and will provide real-time support for SLS launches. The HOSC is a service-oriented/ highly available operations center for ISS payloads-directly supporting science teams across the world responsible for the payloads. The HOSC is required to endure an annual 2-day power outage event for facility preventive maintenance and safety inspection of the core electro-mechanical systems. While complete system shut-downs are against the grain of a highly available sub-system, the entire facility must be powered down for a weekend for environmental and safety purposes. The consequence of this ground system outage is far reaching: any science performed on ISS during this outage weekend is lost. Engineering efforts were focused to maximize the ISS investment by engineering a suitable solution capable of continuing HOSC services while supporting safety requirements. The HOSC Power Outage Contingency (HPOC) System is a physically diversified compliment of systems capable of providing identified real-time services for the duration of a planned power outage condition from an alternate control room. HPOC was designed to maintain ISS payload operations for approximately three continuous days during planned HOSC power outages and support a local Payload Operations Team, International Partners, as well as remote users from the alternate control room located in another building.

  15. An intelligent load shedding scheme using neural networks and neuro-fuzzy.

    PubMed

    Haidar, Ahmed M A; Mohamed, Azah; Al-Dabbagh, Majid; Hussain, Aini; Masoum, Mohammad

    2009-12-01

    Load shedding is some of the essential requirement for maintaining security of modern power systems, particularly in competitive energy markets. This paper proposes an intelligent scheme for fast and accurate load shedding using neural networks for predicting the possible loss of load at the early stage and neuro-fuzzy for determining the amount of load shed in order to avoid a cascading outage. A large scale electrical power system has been considered to validate the performance of the proposed technique in determining the amount of load shed. The proposed techniques can provide tools for improving the reliability and continuity of power supply. This was confirmed by the results obtained in this research of which sample results are given in this paper.

  16. Designing an Alternate Mission Operations Control Room

    NASA Technical Reports Server (NTRS)

    Montgomery, Patty; Reeves, A. Scott

    2014-01-01

    The Huntsville Operations Support Center (HOSC) is a multi-project facility that is responsible for 24x7 real-time International Space Station (ISS) payload operations management, integration, and control and has the capability to support small satellite projects and will provide real-time support for SLS launches. The HOSC is a serviceoriented/ highly available operations center for ISS payloads-directly supporting science teams across the world responsible for the payloads. The HOSC is required to endure an annual 2-day power outage event for facility preventive maintenance and safety inspection of the core electro-mechanical systems. While complete system shut-downs are against the grain of a highly available sub-system, the entire facility must be powered down for a weekend for environmental and safety purposes. The consequence of this ground system outage is far reaching: any science performed on ISS during this outage weekend is lost. Engineering efforts were focused to maximize the ISS investment by engineering a suitable solution capable of continuing HOSC services while supporting safety requirements. The HOSC Power Outage Contingency (HPOC) System is a physically diversified compliment of systems capable of providing identified real-time services for the duration of a planned power outage condition from an alternate control room. HPOC was designed to maintain ISS payload operations for approximately three continuous days during planned HOSC power outages and support a local Payload Operations Team, International Partners, as well as remote users from the alternate control room located in another building. This paper presents the HPOC architecture and lessons learned during testing and the planned maiden operational commissioning. Additionally, this paper documents the necessity of an HPOC capability given the unplanned HOSC Facility power outage on April 27th, 2011, as a result of the tornado outbreak that damaged the electrical grid to such a degree that significantly inhibited the Tennessee Valley Authority's ability to transmit electricity throughout the North Alabama region.

  17. ALARA database value in future outage work planning and dose management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.W.; Green, W.H.

    1995-03-01

    ALARA database encompassing job-specific duration and man-rem plant specific information over three refueling outages represents an invaluable tool for the outage work planner and ALARA engineer. This paper describes dose-management trends emerging based on analysis of three refueling outages at Clinton Power Station. Conclusions reached based on hard data available from a relational database dose-tracking system is a valuable tool for planning of future outage work. The system`s ability to identify key problem areas during a refueling outage is improving as more outage comparative data becomes available. Trends over a three outage period are identified in this paper in themore » categories of number and type of radiation work permits implemented, duration of jobs, projected vs. actual dose rates in work areas, and accuracy of outage person-rem projection. The value of the database in projecting 1 and 5 year station person-rem estimates is discussed.« less

  18. Distortion outage minimization in Nakagami fading using limited feedback

    NASA Astrophysics Data System (ADS)

    Wang, Chih-Hong; Dey, Subhrakanti

    2011-12-01

    We focus on a decentralized estimation problem via a clustered wireless sensor network measuring a random Gaussian source where the clusterheads amplify and forward their received signals (from the intra-cluster sensors) over orthogonal independent stationary Nakagami fading channels to a remote fusion center that reconstructs an estimate of the original source. The objective of this paper is to design clusterhead transmit power allocation policies to minimize the distortion outage probability at the fusion center, subject to an expected sum transmit power constraint. In the case when full channel state information (CSI) is available at the clusterhead transmitters, the optimization problem can be shown to be convex and is solved exactly. When only rate-limited channel feedback is available, we design a number of computationally efficient sub-optimal power allocation algorithms to solve the associated non-convex optimization problem. We also derive an approximation for the diversity order of the distortion outage probability in the limit when the average transmission power goes to infinity. Numerical results illustrate that the sub-optimal power allocation algorithms perform very well and can close the outage probability gap between the constant power allocation (no CSI) and full CSI-based optimal power allocation with only 3-4 bits of channel feedback.

  19. A Method of Synchrophasor Technology for Detecting and Analyzing Cyber-Attacks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCann, Roy; Al-Sarray, Muthanna

    Studying cybersecurity events and analyzing their impacts encourage planners and operators to develop innovative approaches for preventing attacks in order to avoid outages and other disruptions. This work considers two parts in security studies; detecting an integrity attack and examining its effects on power system generators. The detection was conducted through employing synchrophasor technology to provide authentication of ACG commands based on observed system operating characteristics. The examination of an attack is completed via a detailed simulation of a modified IEEE 68-bus benchmark model to show the associated power system dynamic response. The results of the simulation are discussed formore » assessing the impacts of cyber threats.« less

  20. Application of Hybrid Geo-Spatially Granular Fragility Curves to Improve Power Outage Predictions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fernandez, Steven J; Allen, Melissa R; Omitaomu, Olufemi A

    2014-01-01

    Fragility curves depict the relationship between a weather variable (wind speed, gust speed, ice accumulation, precipitation rate) and the observed outages for a targeted infrastructure network. This paper describes an empirical study of the county by county distribution of power outages and one minute weather variables during Hurricane Irene with the objective of comparing 1) as built fragility curves (statistical approach) to engineering as designed (bottom up) fragility curves for skill in forecasting outages during future hurricanes; 2) county specific fragility curves to find examples of significant deviation from average behavior; and 3) the engineering practices of outlier counties tomore » suggest future engineering studies of robustness. Outages in more than 90% of the impacted counties could be anticipated through an average or generic fragility curve. The remaining counties could be identified and handled as exceptions through geographic data sets. The counties with increased or decreased robustness were characterized by terrain more or less susceptible to persistent flooding in areas where above ground poles located their foundations. Land use characteristics of the area served by the power distribution system can suggest trends in the as built power grid vulnerabilities to extreme weather events that would be subjects for site specific studies.« less

  1. Supporting Disaster Assessment and Response with the VIIRS Day-Night Band

    NASA Technical Reports Server (NTRS)

    Schultz, Lori A.; Cole, Tony; Molthan, Andrew L.

    2015-01-01

    When meteorological or man-made disasters occur, first responders often focus on impacts to the affected population and other human activities. Often, these disasters result in significant impacts to local infrastructure and power, resulting in widespread power outages. For minor events, these power outages are often short-lived, but major disasters often include long-term outages that have a significant impact on wellness, safety, and recovery efforts within the affected areas. Staff at NASA's Short-term Prediction Research and Transition (SPoRT) Center have been investigating the use of the VIIRS day-night band for monitoring power outages that result from significant disasters, and developing techniques to identify damaged areas in near real-time following events. In addition to immediate assessment, the VIIRS DNB can be used to monitor and assess ongoing recovery efforts. In this presentation, we will highlight previous applications of the VIIRS DNB following Superstorm Sandy in 2012, and other applications of the VIIRS DNB to more recent disaster events, including detection of outages following the Moore, Oklahoma tornado of May 2013 and the Chilean earthquake of April 2014. Examples of current products will be shown, along with future work and other goals for supporting disaster assessment and response with VIIRS capabilities.

  2. Estimates of outage costs of electricity in Pakistan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashraf, J.; Sabih, F.

    1993-12-31

    This article estimates outage costs of electricity for each of the four provinces in Pakistan (Punjab, North-West Frontier Province, Baluchistan, and Sind). The term {open_quotes}power outage{close_quotes} refers to all problems associated with electricity supply, such as voltage drops (brownouts), power failures (blackouts), and load shedding. The most significant of these in Pakistan is load shedding when power supply to different consumers is shut off during different times of the day, especially during peak hours when the pressure on the system is the highest. Power shortages mainly arise during the low-water months when the effective capacity of hydropower plants drops significantly.more » This decline in power supplied by hydro plants cannot be made up by operating thermal power plants because of the limited availability of gas and the high cost of alternative fuels required for the operation of gas turbines.« less

  3. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... from an electric power outage and directly effects or would directly effect the public health, safety... curtailment. Note—A utility operating hydroelectric facilities may take into account seasonal fluctuations in storage capacity and shall be permitted to prevent depletion of stored power-producing capacity as deemed...

  4. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... from an electric power outage and directly effects or would directly effect the public health, safety... curtailment. Note—A utility operating hydroelectric facilities may take into account seasonal fluctuations in storage capacity and shall be permitted to prevent depletion of stored power-producing capacity as deemed...

  5. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... from an electric power outage and directly effects or would directly effect the public health, safety... curtailment. Note—A utility operating hydroelectric facilities may take into account seasonal fluctuations in storage capacity and shall be permitted to prevent depletion of stored power-producing capacity as deemed...

  6. Health Information in Hindi (हिन्दी)

    MedlinePlus

    ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Power Outages - English PDF Power Outages - हिन्दी (Hindi) Bilingual PDF Health Information ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Nuclear Scans Bone Scan - English PDF Bone Scan - हि ...

  7. The role of the AWS CWI in a major power plant outage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walsh, T.W.

    In March of 1988, an eight-week outage began at the Keystone Electric Generating Station, 35 miles northwest of Johnstown, Pa. This outage encompassed the complete replacement of the reheat section of a 1,7000,000 kW boiler unit, as well as major repairs to the boiler itself. The author discusses how AWS (Certified Welding Inspectors) (CWl's) played a major part in the successful completion of over 7600 ASME butt joint welds during the outage. The welding on these outages is performed in strict accordance with the Pennsylvania Electric Company Quanity Assurance Specification and the applicable codes (ASME, NBIC, ANSI and AWS).

  8. Chattanooga Electric Power Board Case Study Distribution Automation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Jim; Melin, Alexander M.; Starke, Michael R.

    In 2009, the U.S. Department of Energy under the American Recovery and Reinvestment Act (ARRA) awarded a grant to the Chattanooga, Tennessee, Electric Power Board (EPB) as part of the Smart Grid Investment Grant Program. The grant had the objective “to accelerate the transformation of the nation’s electric grid by deploying smart grid technologies.” This funding award enabled EPB to expedite the original smart grid implementation schedule from an estimated 10-12 years to 2.5 years. With this funding, EPB invested heavily in distribution automation technologies including installing over 1,200 automated circuit switches and sensors on 171 circuits. For utilities consideringmore » a commitment to distribution automation, there are underlying questions such as the following: “What is the value?” and “What are the costs?” This case study attempts to answer these questions. The primary benefit of distribution automation is increased reliability or reduced power outage duration and frequency. Power outages directly impact customer economics by interfering with business functions. In the past, this economic driver has been difficult to effectively evaluate. However, as this case study demonstrates, tools and analysis techniques are now available. In this case study, the impact on customer costs associated with power outages before and after the implementation of distribution automation are compared. Two example evaluations are performed to demonstrate the benefits: 1) a savings baseline for customers under normal operations1 and 2) customer savings for a single severe weather event. Cost calculations for customer power outages are performed using the US Department of Energy (DOE) Interruption Cost Estimate (ICE) calculator2. This tool uses standard metrics associated with outages and the customers to calculate cost impact. The analysis shows that EPB customers have seen significant reliability improvements from the implementation of distribution automation. Under normal operations, the investment in distribution automation has enabled a 43.5% reduction in annual outage minutes since 2012. This has led to an estimated total savings of $26.8 million per year. Examining a single severe weather event3, the distribution automation was able to restore power to 40,579 (nearly 56%) customers within 1–2 seconds and reduce outage minutes by 29.0%. This saved customers an estimated $23.2 million over the course of the storm.« less

  9. A computer assisted intelligent storm outage evaluator for power distribution systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balakrishnan, R.; Pahwa, A.

    1990-07-01

    The lower voltage part of the power distribution system (primary and secondary sub-systems) does not have the provision for real-time status feedback, and as a result evaluation of outages is an extremely difficult task, especially during system emergencies caused by tornadoes and ice-storms. In this paper, a knowledge based approach is proposed for evaluation of storm related outages in the distribution systems. At the outset, binary voltage sensors capable of transmitting the real-time voltage on/off symptoms are recommended to be installed at strategic locations in the distribution system.

  10. Characterization of Nighttime Light Variability over the Southeastern United States

    NASA Astrophysics Data System (ADS)

    Cole, T.; Molthan, A.; Schultz, L. A.

    2015-12-01

    Severe meteorological events such as thunderstorms, tropical cyclones and winter ice storms often produce prolonged, widespread power outages affecting large populations and regions. The spatial impact of these events can extend from relatively rural, small towns (i.e. November 17, 2013 Washington, IL EF-4 tornado) to a series of adjoined states (i.e. April 27, 2011 severe weather outbreak) to entire regions (i.e. 2012 Hurricane Sandy) during their lifespans. As such, affected populations can vary greatly, depending on the event's intensity, location and duration. Actions taken by disaster response agencies like FEMA, the American Red Cross and NOAA to provide support to communities during the recovery process need accurate and timely information on the extent and location(s) of power disruption. This information is often not readily available to these agencies given communication interruptions, independent storm damage reports and other response-inhibiting factors. VIIRS DNB observations which provide daily, nighttime measurements of light sources can be used to detect and monitor power outages caused by these meteorological disaster events. To generate such an outage product, normal nighttime light variability must be analyzed and understood at varying spatial scales (i.e individual pixels, clustered land uses/covers, entire city extents). The southeastern portion of the United States serves as the study area in which the mean, median and standard deviation of nighttime lights are examined over numerous temporal periods (i.e. monthly, seasonally, annually, inter-annually). It is expected that isolated pixels with low population density (rural) will have tremendous variability in which an outage "signal" is difficult to detect. Small towns may have more consistent lighting (over a few pixels), making it easier to identify outages and reductions. Finally, large metropolitan areas may be the most "stable" light source, but the entire area may rarely experience a complete outage. The goal is to determine the smallest spatial scale in which an outage can be detected. Presented work will highlight nighttime light variability over the southeastern U.S. which will serve as a baseline for the production of a near real-time power outage product.

  11. Real-time Social Media Data Analytics for Situational Awareness of the Electric Grid

    NASA Astrophysics Data System (ADS)

    Mao, H.; Chinthavali, S.; Lee, S.; Shankar, M.; Thiagarajan, S.

    2016-12-01

    With the increasing frequency of extreme events due to climate change, wide area situational awareness (SA) of the electric grid has become a primary need for federal agencies like DOE,FEMA etc. for emergency preparedness and recovery purposes. While several sensor feeds from Genscape, GridEye, PMUs provide a comprehensive view of the transmission grid, national-scale situational awareness tools are still relying on utility websites for outage information at a distribution level. The inconsistency and the variety in outage website's data formats makes this approach unreliable and also incurs huge software maintenance costs. Social media has emerged as a great medium for the utilities to share outage information with their customers. Despite their potential usefulness, extracting relevant data from these social media data-streams is challenging due to the inherent noise and irrelevant information such as tips to customers during storms, marketing, etc. In this study, we implement a practical and novel machine learning based data-analytics pipeline (Fig 1) for SA, which extracts real-time tweets from around 300 utility companies, processes these tweets using keyword filtering and Naïve-Bayes text classifier trained using supervised learning techniques to detect only relevant tweets. We validated the results by comparing it with the results identified by a human analyst for a period of 48 hours, and it showed around 98.3% accuracy. In addition to the tweets posted by utility companies, millions of twitter users, who are considered as human "social sensors", report power outages online. Therefore, we use Twitter Streaming API to extract real-time tweets containing keywords such as "power outage", "blackout", and "power cuts". An advanced natural language processing technique is proposed to identify the geo-locations associated with this power outage data. The detected tweets are visualized as a color-coded state and a county US map based on the number of outage tweets posted. Therefore, by analyzing a large amount of tweets posted by utilities and the general public, our approach can detect real-time power outages at a national-scale. This framework has been integrated into existing SA tools such as VERDE, EARSS and EAGLE-I, which is deployed by the Oak Ridge National Laboratory for the DOE.

  12. Recent Performance of and Plasma Outage Studies with the SNS H- Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stockli, Martin P; Han, Baoxi; Murray Jr, S N

    2016-01-01

    SNS ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised RFQ, which requires higher RF power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H- beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ~55-kW 2-MHz plasma pulses reflecting ~90% of the continuous ~300W, 13-MHz power, which was mitigated withmore » a 4-ms filter for the reflected power signal and an outage resistant, slightly-detuned 13-MHz match. Lowering the H2 also increased the H- beam current to ~55 mA, and increased the transmission by ~7%.« less

  13. Benchmark Report on Key Outage Attributes: An Analysis of Outage Improvement Opportunities and Priorities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Shawn St.; Farris, Ronald

    2014-09-01

    Advanced Outage Control Center (AOCC), is a multi-year pilot project targeted at Nuclear Power Plant (NPP) outage improvement. The purpose of this pilot project is to improve management of NPP outages through the development of an AOCC that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report documents the results of a benchmarking effort to evaluate the transferability of technologies demonstrated at Idaho National Laboratory and the primary pilot project partner, Palo Verde Nuclear Generating Station. The initial assumption for this pilot project was that NPPs generally domore » not take advantage of advanced technology to support outage management activities. Several researchers involved in this pilot project have commercial NPP experience and believed that very little technology has been applied towards outage communication and collaboration. To verify that the technology options researched and demonstrated through this pilot project would in fact have broad application for the US commercial nuclear fleet, and to look for additional outage management best practices, LWRS program researchers visited several additional nuclear facilities.« less

  14. Method for estimating power outages and restoration during natural and man-made events

    DOEpatents

    Omitaomu, Olufemi A.; Fernandez, Steven J.

    2016-01-05

    A method of modeling electric supply and demand with a data processor in combination with a recordable medium, and for estimating spatial distribution of electric power outages and affected populations. A geographic area is divided into cells to form a matrix. Within the matrix, supply cells are identified as containing electric substations and demand cells are identified as including electricity customers. Demand cells of the matrix are associated with the supply cells as a function of the capacity of each of the supply cells and the proximity and/or electricity demand of each of the demand cells. The method includes estimating a power outage by applying disaster event prediction information to the matrix, and estimating power restoration using the supply and demand cell information of the matrix and standardized and historical restoration information.

  15. Operations and Maintenance May Newsletter | Poster

    Cancer.gov

    Occurring without notice, unscheduled utility outages (mainly electrical) are abrupt and create a nuisance. During an unscheduled electrical power outage, the Operations and Maintenance (O&M) department will monitor stand-by generators for proper operation.

  16. Using Predictive Analytics to Predict Power Outages from Severe Weather

    NASA Astrophysics Data System (ADS)

    Wanik, D. W.; Anagnostou, E. N.; Hartman, B.; Frediani, M. E.; Astitha, M.

    2015-12-01

    The distribution of reliable power is essential to businesses, public services, and our daily lives. With the growing abundance of data being collected and created by industry (i.e. outage data), government agencies (i.e. land cover), and academia (i.e. weather forecasts), we can begin to tackle problems that previously seemed too complex to solve. In this session, we will present newly developed tools to aid decision-support challenges at electric distribution utilities that must mitigate, prepare for, respond to and recover from severe weather. We will show a performance evaluation of outage predictive models built for Eversource Energy (formerly Connecticut Light & Power) for storms of all types (i.e. blizzards, thunderstorms and hurricanes) and magnitudes (from 20 to >15,000 outages). High resolution weather simulations (simulated with the Weather and Research Forecast Model) were joined with utility outage data to calibrate four types of models: a decision tree (DT), random forest (RF), boosted gradient tree (BT) and an ensemble (ENS) decision tree regression that combined predictions from DT, RF and BT. The study shows that the ENS model forced with weather, infrastructure and land cover data was superior to the other models we evaluated, especially in terms of predicting the spatial distribution of outages. This research has the potential to be used for other critical infrastructure systems (such as telecommunications, drinking water and gas distribution networks), and can be readily expanded to the entire New England region to facilitate better planning and coordination among decision-makers when severe weather strikes.

  17. Utilities bullish on meter-reading technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garner, W.L.

    1995-01-15

    By the end of 1996, the 400,000 customers of Kansas City Power & Light Company (KCPL) will have their electric meters read by a real-time wireless network that will relay electrical consumption readings back to computers at the utility`s customer service office. KCPL`s executives believe the new radio and cellular network will greatly improve the company`s ability to control its power distribution, manage its load requirements, monitor outages, and in the near future, allow time-of-use and offpeak pricing. The KCPL system represents the first systemwide, commercial application of wireless automated meter reading (AMR) by a U.S. utility. The article alsomore » describes other AMR systems for reading water and gas meters, along with saying that $18 billion in future power plant investments can be avoided by using time-of-use pricing for residential customers.« less

  18. Emergency preparedness for power outages and wi-fi loss: tips for students and educators of online courses.

    PubMed

    Heithaus, Teresa

    2015-01-01

    Severe weather can impact online education due to a loss of power and Internet access that can last hours or weeks. Planning for such losses is essential to enable participation in the online classroom. This article discusses measures that can be used to maintain an online presence in the event of a power outage or loss of Wi-Fi. Copyright 2015, SLACK Incorporated.

  19. Human Factors and Modeling Methods in the Development of Control Room Modernization Concepts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hugo, Jacques V.; Slay III, Lorenzo

    nuclear power plants. Although the nuclear industry has made steady improvement in outage optimization, each day of a refueling outage still represents an opportunity to save millions of dollars and each day an outage extends past its planned end date represents millions of dollars that may have been spent unnecessarily. Reducing planned outage duration or preventing outage extensions requires careful management of the outage schedule as well as constant oversight and monitoring of work completion during the outage execution. During a typical outage, there are typically more than 10,000 activities on the schedule that, if not managed efficiently, may causemore » expensive outage delays. Management of outages currently relies largely on paper-based resources and general-purpose office software. A typical tool currently used to monitor work performance is a burn-down curve, where total remaining activities are plotted against the baseline schedule to track bulk work completion progress. While these tools are useful, there is still considerable uncertainty during a typical outage that bulk work progress is adequate and therefore a lot of management time is spent analyzing the situation on a daily basis. This paper describes recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the scientific principles that informed the development of the visualizations. To test the utility of advanced visual outage information presentation, an outage management dashboard software application was created as part of the Department of Energy’s Advanced Outage Control Center project. This dashboard is intended to present all the critical information an outage manager would need to understand the current status of a refueling outage. The dashboard presents the critical path, bulk work performance, key performance indicators, outage milestones and metrics relating current performance to historical performance. Additionally, the dashboard includes data analysis tools to allow outage managers to drill down into the underlying data to understand the drivers of the indicators.« less

  20. Are Older Adults Prepared to Ensure Food Safety during Extended Power Outages and Other Emergencies?: Findings from a National Survey

    ERIC Educational Resources Information Center

    Kosa, Katherine M.; Cates, Sheryl C.; Karns, Shawn; Godwin, Sandria L.; Coppings, Richard J.

    2012-01-01

    Natural disasters and other emergencies can cause an increased risk of foodborne illness. We conducted a nationally representative survey to understand consumers' knowledge and use of recommended practices during/after extended power outages and other emergencies. Because older adults are at an increased risk for foodborne illness, this paper…

  1. A High Resolution Tropical Cyclone Power Outage Forecasting Model for the Continental United States

    NASA Astrophysics Data System (ADS)

    Pino, J. V.; Quiring, S. M.; Guikema, S.; Shashaani, S.; Linger, S.; Backhaus, S.

    2017-12-01

    Tropical cyclones cause extensive damage to the power infrastructure system throughout the United States. This damage can leave millions without power for extended periods of time, as most recently seen with Hurricane Matthew (2016). Accurate and timely prediction of power outages are essential for utility companies, emergency management agencies, and governmental organizations. Here we present a high-resolution (250 m x 250 m) hurricane power outage model for the United States. The model uses only publicly-available data to make predictions. It uses forecasts of storm variables such as maximum 3-second wind gust, duration of strong winds > 20 m s-2, soil moisture, and precipitation. It also incorporates static environmental variables such as elevation characteristics, land cover type, population density, tree species data, and root zone depth. A web tool was established for use by the Department of Energy (DOE) so that the model can be used for real-time outage forecasting or for synthetic tropical cyclones as an exercise in emergency management. This web tool provides DOE decision-makers with high impact analytic results and products that can be disseminated to federal, local, and state agencies. The results then aid utility companies in their pre- and post-storm activities, thus decreasing restoration times and lowering costs.

  2. Outage differences between Diablo Canyon and Unterweser power plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehrens, H.

    Diablo Canyon (DCPP) of Pacific Gas and Electric Company and Unterweser (KKU) of PreussenElektra have had an ongoing exchange program since 1989, which includes mutual visits by their employees at the optimum time for observing outages. Both DCPP and Unterweser use four-loop pressurized water reactors (PWRs), DCPP with two 1,100-MW units and KKU with a single 1,300-MW unit. Unterweser finished its 11th outage in 1990; DCPP units 1 and 2 will have their fourth outages in 1991. The scope of the maintenance and refueling work is quite similar in both plants and offers, therefore, a good basis for comparison. Outagemore » durations at European Kraftwerk Union KWU-PWR plants average {approximately}30 days as compared to the 60 to 80 days for PWRs in the US. Diablo Canyon has reduced outage durations from > 100 days to < 60. The key areas that contribute to the differences in outage duration are plant design and layout and outage execution.« less

  3. Towards Availability and Maintainability Benchmarks: A Case Study of Software RAID Systems

    DTIC Science & Technology

    2001-01-01

    on recent outages of big e-commerce providers and the major business impact of those out- ages is staggering; furthermore, several of those outages...uses one or more clients to generate a realistic, statistically reproducible web workload; its workload models what might be seen on a busy major server...the amount of dynamic content from 30% to 1% to keep the disks busy and to avoid saturating the CPU. This restriction was necessary because we used

  4. Recent performance of and plasma outage studies with the SNS H{sup −} source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stockli, M. P., E-mail: stockli@ornl.gov; Han, B.; Murray, S. N.

    2016-02-15

    Spallation Neutron Source ramps to higher power levels that can be sustained with high availability. The goal is 1.4 MW despite a compromised radio frequency quadrupole (RFQ), which requires higher radio frequency power than design levels to approach the nominal beam transmission. Unfortunately at higher power the RFQ often loses its thermal stability, a problem apparently enhanced by beam losses and high influxes of hydrogen. Delivering as much H{sup −} beam as possible with the least amount of hydrogen led to plasma outages. The root cause is the dense 1-ms long ∼55-kW 2-MHz plasma pulses reflecting ∼90% of the continuousmore » ∼300 W, 13-MHz power, which was mitigated with a 4-ms filter for the reflected power signal and an outage resistant, slightly detuned 13-MHz match. Lowering the H{sub 2} gas also increased the H{sup −} beam current to ∼55 mA and increased the RFQ transmission by ∼7% (relative)« less

  5. Decision support system for outage management and automated crew dispatch

    DOEpatents

    Kang, Ning; Mousavi, Mirrasoul

    2018-01-23

    A decision support system is provided for utility operations to assist with crew dispatch and restoration activities following the occurrence of a disturbance in a multiphase power distribution network, by providing a real-time visualization of possible location(s). The system covers faults that occur on fuse-protected laterals. The system uses real-time data from intelligent electronics devices coupled with other data sources such as static feeder maps to provide a complete picture of the disturbance event, guiding the utility crew to the most probable location(s). This information is provided in real-time, reducing restoration time and avoiding more costly and laborious fault location finding practices.

  6. Diarrheal Illness Detected Through Syndromic Surveillance After a Massive Power Outage: New York City, August 2003

    PubMed Central

    Marx, Melissa A.; Rodriguez, Carla V.; Greenko, Jane; Das, Debjani; Heffernan, Richard; Karpati, Adam M.; Mostashari, Farzad; Balter, Sharon; Layton, Marcelle; Weiss, Don

    2006-01-01

    Objectives. We investigated increases in diarrheal illness detected through syndromic surveillance after a power outage in New York City on August 14, 2003. Methods. The New York City Department of Health and Mental Hygiene uses emergency department, pharmacy, and absentee data to conduct syndromic surveillance for diarrhea. We conducted a case–control investigation among patients presenting during August 16 to 18, 2003, to emergency departments that participated in syndromic surveillance. We compared risk factors for diarrheal illness ascertained through structured telephone interviews for case patients presenting with diarrheal symptoms and control patients selected from a stratified random sample of nondiarrheal patients. Results. Increases in diarrhea were detected in all data streams. Of 758 patients selected for the investigation, 301 (40%) received the full interview. Among patients 13 years and older, consumption of meat (odds ratio [OR]=2.7, 95% confidence interval [CI]=1.2, 6.1) and seafood (OR=4.8; 95% CI=1.6, 14) between the power outage and symptom onset was associated with diarrheal illness. Conclusions. Diarrhea may have resulted from consumption of meat or seafood that spoiled after the power outage. Syndromic surveillance enabled prompt detection and systematic investigation of citywide illness that would otherwise have gone undetected. PMID:16380562

  7. Monitoring Disaster-Related Power Outages Using NASA Black Marble Nighttime Light Product

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Román, M. O.; Sun, Q.; Molthan, A. L.; Schultz, L. A.; Kalb, V. L.

    2018-04-01

    Timely and accurate monitoring of disruptions to the electricity grid, including the magnitude, spatial extent, timing, and duration of net power losses, is needed to improve situational awareness of disaster response and long-term recovery efforts. Satellite-derived Nighttime Lights (NTL) provide an indication of human activity patterns and have been successfully used to monitor disaster-related power outages. The global 500 m spatial resolution National Aeronautics and Space Administration (NASA) Black Marble NTL daily standard product suite (VNP46) is generated from Visible Infrared Imaging Radiometer Suite (VIIRS) Day/Night Band (DNB) onboard the NASA/National Oceanic and Atmospheric Administration (NOAA) Suomi National Polar-orbiting Partnership (Suomi- NPP) satellite, which began operations on 19 January 2012. With its improvements in product accuracy (including critical atmospheric and BRDF correction routines), the VIIRS daily Black Mable product enables systematic monitoring of outage conditions across all stages of the disaster management cycle.

  8. Back Propagation Artificial Neural Network and Its Application in Fault Detection of Condenser Failure in Thermo Plant

    NASA Astrophysics Data System (ADS)

    Ismail, Firas B.; Thiruchelvam, Vinesh

    2013-06-01

    Steam condenser is one of the most important equipment in steam power plants. If the steam condenser trips it may lead to whole unit shutdown, which is economically burdensome. Early condenser trips monitoring is crucial to maintain normal and safe operational conditions. In the present work, artificial intelligent monitoring systems specialized in condenser outages has been proposed and coded within the MATLAB environment. The training and validation of the system has been performed using real operational measurements captured from the control system of selected steam power plant. An integrated plant data preparation scheme for condenser outages with related operational variables has been proposed. Condenser outages under consideration have been detected by developed system before the plant control system"

  9. Dose reduction and cost-benefit analysis at Japan`s Tokai No. 2 Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humamoto, Hisao; Suzuki, Seishiro; Taniguchi, Kazufumi

    1995-03-01

    In the Tokai No. 2 power plant of the Japan Atomic Power Company, about 80% of the annual dose equivalent is received during periodic maintenance outages. A project group for dose reduction was organized at the company`s headquarters in 1986; in 1988, they proposed a five-year program to reduce by half the collective dose of 4 person-Sv per normal outage work. To achieve the target dose value, some dose-reduction measures were undertaken, namely, permanent radiation shielding, decontamination, automatic, operating machines, and ALARA organization. As the result, the collective dose from normal outage work was 1.6 person-Sv in 1992, which wasmore » less than the initial target value.« less

  10. Impact of Distributed Energy Resources on the Reliability of a Critical Telecommunications Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, D.; Atcitty, C.; Zuffranieri, J.

    2006-03-01

    Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages, as documented by analyses of Federal Communications Commission (FCC) outage reports by the National Reliability Steering Committee (under auspices of the Alliance for Telecommunications Industry Solutions). There are two major issues that are having increasing impact on the sensitivity of the power distribution to telecommunication facilities: deregulation of the power industry, and changing weather patterns. A logical approach to improve the robustness of telecommunicationmore » facilities would be to increase the depth and breadth of technologies available to restore power in the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. But does the diversity in power sources actually increase the reliability of offered power to the office equipment, or does the complexity of installing and managing the extended power system induce more potential faults and higher failure rates? This report analyzes a system involving a telecommunications facility consisting of two switch-bays and a satellite reception system.« less

  11. Status Report on the Development of Micro-Scheduling Software for the Advanced Outage Control Center Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Shawn St.; Thomas, Kenneth; Farris, Ronald

    2014-09-01

    The long-term viability of existing nuclear power plants (NPPs) in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet, refueling outages are highly complex operations, involving multiple concurrent and dependentmore » activities that are difficult to coordinate. Finding ways to improve refueling outage performance while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center project is a research and development (R&D) demonstration activity under the Light Water Reactor Sustainability (LWRS) Program. LWRS is a R&D program which works with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current NPPs. The Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, this INL R&D project is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report describes specific recent efforts to develop a capability called outage Micro-Scheduling. Micro-Scheduling is the ability to allocate and schedule outage support task resources on a sub-hour basis. Micro-Scheduling is the real-time fine-tuning of the outage schedule to react to the actual progress of the primary outage activities to ensure that support task resources are optimally deployed with the least amount of delay and unproductive use of resources. The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how a Micro-Scheduling capability helps address those challenges, and provides a status update on work accomplished to date and the path forward.« less

  12. 76 FR 23171 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... (MW and MVAR), or system configuration to maintain system stability, acceptable voltage or power flows... identified system conditions to prevent system instability or cascading outages, and protect other facilities... instability, cascading outages, and protect other facilities in response to contingencies. Therefore, a...

  13. Disparities in nuclear power plant performance in the United States and the Federal Republic of Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, K.F.; Winje, D.K.

    This report presents data comparing the performance of light water reactors in the United States and the Federal Republic of Germany (FRG). The comparisons are made for the years 1980-1983 and include 21 Westinghouse Pressurized Water Reactors (PWRs), 22 General Electric Boiling Water Reactors (BWRs) in the US; and 6 Kraftwerk Union (KWU) PWRs and 4 KWJ BWRs in the FRG. Data on capacity losses are presented in a disaggregated form for scheduled outages, forced outages, and regulatory imposed outages. Further, within the scheduled and forced outages, the data is subdivided into losses associated with the nuclear island, the balancemore » of plant, or other causes.« less

  14. An Internet of Things Approach to Electrical Power Monitoring and Outage Reporting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, Daniel B

    The so-called Internet of Things concept has captured much attention recently as ordinary devices are connected to the Internet for monitoring and control purposes. One enabling technology is the proliferation of low-cost, single board computers with built-in network interfaces. Some of these are capable of hosting full-fledged operating systems that provide rich programming environments. Taken together, these features enable inexpensive solutions for even traditional tasks such as the one presented here for electrical power monitoring and outage reporting.

  15. Reliability analysis of a utility-scale solar power plant

    NASA Astrophysics Data System (ADS)

    Kolb, G. J.

    1992-10-01

    This paper presents the results of a reliability analysis for a solar central receiver power plant that employs a salt-in-tube receiver. Because reliability data for a number of critical plant components have only recently been collected, this is the first time a credible analysis can be performed. This type of power plant will be built by a consortium of western US utilities led by the Southern California Edison Company. The 10 MW plant is known as Solar Two and is scheduled to be on-line in 1994. It is a prototype which should lead to the construction of 100 MW commercial-scale plants by the year 2000. The availability calculation was performed with the UNIRAM computer code. The analysis predicted a forced outage rate of 5.4 percent and an overall plant availability, including scheduled outages, of 91 percent. The code also identified the most important contributors to plant unavailability. Control system failures were identified as the most important cause of forced outages. Receiver problems were rated second with turbine outages third. The overall plant availability of 91 percent exceeds the goal identified by the US utility study. This paper discuses the availability calculation and presents evidence why the 91 percent availability is a credible estimate.

  16. Outage Analysis of Dual-hop Cognitive Networks with Relay Selection over Nakagami-m Fading Environment

    NASA Astrophysics Data System (ADS)

    Zhang, Zongsheng; Pi, Xurong

    2014-09-01

    In this paper, we investigate the outage performance of decode-and-forward cognitive relay networks for Nakagami-m fading channels, with considering both best relay selection and interference constraints. Focusing on the relay selection and making use of the underlay cognitive approach, an exact closed-form outage probability expression is derived in an independent, non-identical distributed Nakagami-m environment. The closed-form outage probability provides an efficient means to evaluate the effects of the maximum allowable interference power, number of cognitive relays, and channel conditions between the primary user and cognitive users. Finally, we present numerical results to validate the theory analysis. Moreover, from the simulation results, we obtain that the system can obtain the full diversity.

  17. Hospital emergency department visits for carbon monoxide poisoning following an October 2006 snowstorm in western New York.

    PubMed

    Muscatiello, Neil A; Babcock, Gwen; Jones, Rena; Horn, Edward; Hwang, Syni-An

    2010-01-01

    Following an October 2006 snowstorm that caused widespread power outages in western New York State, hospital emergency department (ED) visits for carbon monoxide (CO) poisoning increased. Overall, 264 people representing 155 households were diagnosed with CO poisoning during the power outages. Telephone interviews were conducted with a subset of these individuals. Respondents provided information about exposure sources, CO alarms, and awareness of CO warnings. In many households, portable generators were operated in an enclosed area. Awareness of CO warnings may have contributed to knowledge about locating portable generators outside. When operated outside, however, portable generators were generally located too close to the home. Gas kitchen ranges were used for heat by numerous households. In the short term, CO education and improved clarity of CO warning information is important for increasing awareness about power outage-related CO risks. Improvements in the combustion efficiency of portable generators should be a long-term goal.

  18. Minimizing forced outage risk in generator bidding

    NASA Astrophysics Data System (ADS)

    Das, Dibyendu

    Competition in power markets has exposed the participating companies to physical and financial uncertainties. Generator companies bid to supply power in a day-ahead market. Once their bids are accepted by the ISO they are bound to supply power. A random outage after acceptance of bids forces a generator to buy power from the expensive real-time hourly spot market and sell to the ISO at the set day-ahead market clearing price, incurring losses. A risk management technique is developed to assess this financial risk associated with forced outages of generators and then minimize it. This work presents a risk assessment module which measures the financial risk of generators bidding in an open market for different bidding scenarios. The day-ahead power market auction is modeled using a Unit Commitment algorithm and a combination of Normal and Cauchy distributions generate the real time hourly spot market. Risk profiles are derived and VaRs are calculated at 98 percent confidence level as a measure of financial risk. Risk Profiles and VaRs help the generators to analyze the forced outage risk and different factors affecting it. The VaRs and the estimated total earning for different bidding scenarios are used to develop a risk minimization module. This module will develop a bidding strategy of the generator company such that its estimated total earning is maximized keeping the VaR below a tolerable limit. This general framework of a risk management technique for the generating companies bidding in competitive day-ahead market can also help them in decisions related to building new generators.

  19. Coordinated train control and energy management control strategies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, S.P.; Lehrer, D.G.

    1998-05-01

    The Bay Area Rapid Transit (BART) system, in collaboration with Hughes Aircraft Company and Harmon Industries, as in the process of developing an Advanced Automatic Train Control (AATC) system to replace the current fixed-block automatic system. In the long run, the AATC system is expected to not only allow for safe short headway operation, but also to facilitate coordinated train control and energy management. This new system will employ spread spectrum radios, installed onboard trains, at wayside locations, and at control stations, to determine train locations and reliably transfer control information. Sandia National Laboratories has worked cooperatively with BART tomore » develop a simulator of the train control and the power consumption of the AATC system. The authors are now in the process of developing enhanced train control algorithms to supplement the safety critical controller in order to smooth out train trajectories through coordinated control of multiple trains, and to reduce energy consumption and power infrastructure requirements. The control algorithms so far considered include (1) reducing peak power consumption to avoid voltage sags, especially during an outage or while clearing a backup, (2) rapid and smooth recovery from a backup, (3) avoiding oscillations due to train interference, (4) limiting needle peaks in power demand at substations to some specified level, (5) coasting, and (6) coordinating train movement, e.g., starts/stops and hills.« less

  20. Protective Controller against Cascade Outages with Selective Harmonic Compensation Function

    NASA Astrophysics Data System (ADS)

    Abramovich, B. N.; Kuznetsov, P. A.; Sychev, Yu A.

    2018-05-01

    The paper presents data on the power quality and development of protective devices for the power networks with distributed generation (DG).The research has shown that power quality requirements for DG networks differ from conventional ones. That is why main tendencies, protective equipment and filters should be modified. There isa developed algorithm for detection and prevention of cascade outages that can lead to the blackoutin DG networks and there was a proposed structural scheme for a new active power filter for selective harmonics compensation. Analysis of these theories and equipment led to the development of protective device that could monitor power balance and cut off non-important consumers. The last part of the article describes a microcontroller prototype developed for connection to the existing power station control center.

  1. 75 FR 13320 - Florida Power Corporation, et al., Crystal River Unit 3 Nuclear Generating Plant; Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ... replacement outage that is currently underway at CR-3. In addition to steam generators, other large components (e.g., moisture separators and large heat exchangers) are being replaced during this outage... on the Internet at the NRC Web site: http://www.nrc.gov/reading-rm/adams.html . Persons who do not...

  2. Energy Resiliency for Marine Corps Logistics Base Production Plant Barstow

    DTIC Science & Technology

    2014-12-01

    13 1. Biomass, Landfill Gas, and Biogas ...value in dollar per kilowatts ($/kW) peak of an outage cost obtained from the CDF curve for a specified duration of the interruption” (Giraldez, Booth...length of outages for inclusion in the VEES calculation, we needed to obtain power interruption and circuit reliability data from PPB’s utility

  3. Terrestrial Energy Storage SPS Systems

    NASA Technical Reports Server (NTRS)

    Brandhorst, Henry W., Jr.

    1998-01-01

    Terrestrial energy storage systems for the SSP system were evaluated that could maintain the 1.2 GW power level during periods of brief outages from the solar powered satellite (SPS). Short-term outages of ten minutes and long-term outages up to four hours have been identified as "typical" cases where the ground-based energy storage system would be required to supply power to the grid. These brief interruptions in transmission could result from performing maintenance on the solar power satellite or from safety considerations necessitating the power beam be turned off. For example, one situation would be to allow for the safe passage of airplanes through the space occupied by the beam. Under these conditions, the energy storage system needs to be capable of storing 200 MW-hrs and 4.8 GW-hrs, respectively. The types of energy storage systems to be considered include compressed air energy storage, inertial energy storage, electrochemical energy storage, superconducting magnetic energy storage, and pumped hydro energy storage. For each of these technologies, the state-of-the-art in terms of energy and power densities were identified as well as the potential for scaling to the size systems required by the SSP system. Other issues addressed included the performance, life expectancy, cost, and necessary infrastructure and site locations for the various storage technologies.

  4. Optimal Power Allocation for CC-HARQ-based Cognitive Radio with Statistical CSI in Nakagami Slow Fading Channels

    NASA Astrophysics Data System (ADS)

    Xu, Ding; Li, Qun

    2017-01-01

    This paper addresses the power allocation problem for cognitive radio (CR) based on hybrid-automatic-repeat-request (HARQ) with chase combining (CC) in Nakagamimslow fading channels. We assume that, instead of the perfect instantaneous channel state information (CSI), only the statistical CSI is available at the secondary user (SU) transmitter. The aim is to minimize the SU outage probability under the primary user (PU) interference outage constraint. Using the Lagrange multiplier method, an iterative and recursive algorithm is derived to obtain the optimal power allocation for each transmission round. Extensive numerical results are presented to illustrate the performance of the proposed algorithm.

  5. Development of Improved Graphical Displays for an Advanced Outage Control Center, Employing Human Factors Principles for Outage Schedule Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St Germain, Shawn Walter; Farris, Ronald Keith; Thomas, Kenneth David

    The long-term viability of existing nuclear power plants in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet refueling outages are highly complex operations, involving multiple concurrent and dependent activitiesmore » that are somewhat challenging to coordinate; therefore, finding ways to improve refueling outage performance, while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center (AOCC) project is a research and development (R&D) demonstration activity under the LWRS Program. LWRS is an R&D program that works closely with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current fleet of NPPs. As such, the LWRS Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, INL is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. The overall focus is on developing an AOCC with the following capabilities that enables plant and OCC staff to; Collaborate in real-time to address emergent issues; Effectively communicate outage status to all workers involved in the outage; Effectively communicate discovered conditions in the field to the OCC; Provide real-time work status; Provide automatic pending support notifications; Provide real-time requirements monitoring; Maximize their collective situational awareness to improve decision-making; and Leverage macro data to better support resource allocation. INL has partnered with several commercial NPP utilities to develop a number of advanced outage management technologies. These outage management technologies have focused on both collaborative technologies for control centers and developing mobile technologies for NPP field workers. This report describes recent efforts made in developing a suite of outage technologies to support more effective schedule management. Currently, a master outage schedule is created months in advance using the plant’s existing scheduling software (e.g., Primavera P6). Typically, during the outage, the latest version of the schedule is printed at the beginning of each shift. INL and its partners are developing technologies that will have capabilities such as Automatic Schedule Updating, Automatic Pending Support Notifications, and the ability to allocate and schedule outage support task resources on a sub-hour basis (e.g., outage Micro-Scheduling). The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how the outage scheduling technologies INL is developing helps address those challenges, and the latest developments on this task (e.g., work accomplished to date and the path forward)« less

  6. Use of VIIRS DNB Data to Monitor Power Outages and Restoration for Significant Weather Events

    NASA Technical Reports Server (NTRS)

    Jedlovec, Gary; Molthan, Andrew

    2008-01-01

    NASA fs Short-term Prediction Research and Transition (SPoRT) project operates from NASA's Marshall Space Flight Center in Huntsville, Alabama. The team provides unique satellite data to the National Weather Service (NWS) and other agencies and organizations for weather analysis. While much of its work is focused on improving short-term weather forecasting, the SPoRT team supported damage assessment and response to Hurricane Superstorm Sandy by providing imagery that highlighted regions without power. The team used data from the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (Suomi NPP) satellite. The VIIRS low-light sensor, known as the day-night-band (DNB), can detect nighttime light from wildfires, urban and rural communities, and other human activity which emits light. It can also detect moonlight reflected from clouds and surface features. Using real time VIIRS data collected by our collaborative partner at the Space Science and Engineering Center of the University of Wisconsin, the SPoRT team created composite imagery to help detect power outages and restoration. This blackout imagery allowed emergency response teams from a variety of agencies to better plan and marshal resources for recovery efforts. The blackout product identified large-scale outages, offering a comprehensive perspective beyond a patchwork GIS mapping of outages that utility companies provide based on customer complaints. To support the relief efforts, the team provided its imagery to the USGS data portal, which the Federal Emergency Management Agency (FEMA) and other agencies used in their relief efforts. The team fs product helped FEMA, the U.S. Army Corps of Engineers, and U.S. Army monitor regions without power as part of their disaster response activities. Disaster responders used the images to identify possible outages and effectively distribute relief resources. An enhanced product is being developed and integrated into a web mapping service (WMS) for dissemination and use by a broader end user community.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Shawn

    Nuclear Power Plant (NPP) refueling outages create some of the most challenging activities the utilities face in both tracking and coordinating thousands of activities in a short period of time. Other challenges, including nuclear safety concerns arising from atypical system configurations and resource allocation issues, can create delays and schedule overruns, driving up outage costs. Today the majority of the outage communication is done using processes that do not take advantage of advances in modern technologies that enable enhanced communication, collaboration and information sharing. Some of the common practices include: runners that deliver paper-based requests for approval, radios, telephones, desktopmore » computers, daily schedule printouts, and static whiteboards that are used to display information. Many gains have been made to reduce the challenges facing outage coordinators; however; new opportunities can be realized by utilizing modern technological advancements in communication and information tools that can enhance the collective situational awareness of plant personnel leading to improved decision-making. Ongoing research as part of the Light Water Reactor Sustainability Program (LWRS) has been targeting NPP outage improvement. As part of this research, various applications of collaborative software have been demonstrated through pilot project utility partnerships. Collaboration software can be utilized as part of the larger concept of Computer-Supported Cooperative Work (CSCW). Collaborative software can be used for emergent issue resolution, Outage Control Center (OCC) displays, and schedule monitoring. Use of collaboration software enables outage staff and subject matter experts (SMEs) to view and update critical outage information from any location on site or off.« less

  8. Moisture separator reheater upgrade at Surry nuclear power station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bankley, A.

    1985-01-01

    Surry station moisture separator reheaters (MSRs) have experienced numerous problems typical of those found in MSRs of large nuclear power plants. The reliability of MSRs has been of concern to users for several years, primarily in regard to their structural integrity, operational characteristics and performance. Gross MSR internal problems such as reheater tube failures, inadequate moisture separation, buckling, and distortion of internal components occasionally necessitate forced outages or nonscheduled repairs or removal of a particular MSR from operation until repairs can be performed during a scheduled outage. It was obvious that the financial consequences of forced outages or reduced performancemore » were grave and their elimination was an important betterment goal. The objective of this paper is to present past failures of MSRs and modifications that were made to the vessel internals, and to compare their performance prior to and after the improved design was implemented.« less

  9. Capacity Improvement of a Free Space Optical Satellite Uplink using Transmitter Power and Rate Adaptation

    NASA Astrophysics Data System (ADS)

    Gopal, Pooja; Jain, V. K.; Kar, Subrat

    2017-12-01

    Degradation due to atmospheric turbulence leads to significant outage in a free space optical satellite uplink with fixed transmitter parameters. If the channel state is known at the transmitter, then its parameters can be suitably changed, and there could be a considerable improvement in channel capacity. However, the extremely long link length of an Earth-to-Geostationary Earth Orbit (GEO) satellite link would render feedback of channel state from the receiver infeasible, before the channel changes. In this paper, a channel pre-estimation method at the transmitter is proposed, and the expression for capacity with transmitter power and rate adaptation is derived. The results are compared with that of the capacity with outage. It is observed that there can be an improvement by a factor of 1.66 in achievable average capacity per Hertz with the adaptive transmitter. Also, the outage probability is reduced from 18.02 % to almost 0.

  10. Automatic scheduling of outages of nuclear power plants with time windows. Final report, January-December 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gomes, C.

    This report describes a successful project for transference of advanced AI technology into the domain of planning of outages of nuclear power plants as part of DOD`s dual-use program. ROMAN (Rome Lab Outage Manager) is the prototype system that was developed as a result of this project. ROMAN`s main innovation compared to the current state-of-the-art of outage management tools is its capability to automatically enforce safety constraints during the planning and scheduling phase. Another innovative aspect of ROMAN is the generation of more robust schedules that are feasible over time windows. In other words, ROMAN generates a family of schedulesmore » by assigning time intervals as start times to activities rather than single start times, without affecting the overall duration of the project. ROMAN uses a constraint satisfaction paradigm combining a global search tactic with constraint propagation. The derivation of very specialized representations for the constraints to perform efficient propagation is a key aspect for the generation of very fast schedules - constraints are compiled into the code, which is a novel aspect of our work using an automatic programming system, KIDS.« less

  11. Power System Reliability Assessment by Analysing Voltage Dips on the Blue Horizon Bay 22KV Overhead Line in the Nelson Mandela Bay Municipality

    NASA Astrophysics Data System (ADS)

    Lamour, B. G.; Harris, R. T.; Roberts, A. G.

    2010-06-01

    Power system reliability problems are very difficult to solve because the power systems are complex and geographically widely distributed and influenced by numerous unexpected events. It is therefore imperative to employ the most efficient optimization methods in solving the problems relating to reliability of the power system. This paper presents a reliability analysis and study of the power interruptions resulting from severe power outages in the Nelson Mandela Bay Municipality (NMBM), South Africa and includes an overview of the important factors influencing reliability, and methods to improve the reliability. The Blue Horizon Bay 22 kV overhead line, supplying a 6.6 kV residential sector has been selected. It has been established that 70% of the outages, recorded at the source, originate on this feeder.

  12. Outage management and health physics issue, 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2007-05-15

    The focus of the May-June issue is on outage management and health physics. Major articles/reports in this issue include: India: a potential commercial opportunity, a U.S. Department of Commerce Report, by Joe Neuhoff and Justin Rathke; The changing climate for nuclear energy, by Skip Bowman, Nuclear Energy Insitute; Selecting protective clothing, by J. Mark Price, Southern California Edison; and Succssful refurbishment outage, by Sudesh K. Gambhir, Omaha Public Power District. Industry innovation articles in this issue are: Containment radiation monitoring spiking, by Michael W. Lantz and Robert Routolo, Arizona Public Service Company; Improved outage performance, by Michael Powell and Troymore » Wilfong, Arizona Public Service Company, Palo Verde Nuclear Generating Station; Stop repacking valves and achieve leak-free performance, by Kenneth Hart, PPL Susquehanna LLC; and Head assembly upgrade package, by Timothy Petit, Dominion Nuclear.« less

  13. Guidelines for Implementation of an Advanced Outage Control Center to Improve Outage Coordination, Problem Resolution, and Outage Risk Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St. Germain, Shawn W.; Farris, Ronald K.; Whaley, April M.

    This research effort is a part of the Light-Water Reactor Sustainability (LWRS) Program, which is a research and development (R&D) program sponsored by Department of Energy (DOE) and performed in close collaboration with industry R&D programs that provide the technical foundations for licensing and managing the long-term, safe, and economical operation of current nuclear power plants. The LWRS program serves to help the U.S. nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The purpose of this research is to improve management of nuclear powermore » plant (NPP) outages through the development of an advanced outage control center (AOCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This technical report for industry implementation outlines methods and considerations for the establishment of an AOCC. This report provides a process for implementation of a change management plan, evaluation of current outage processes, the selection of technology, and guidance for the implementation of the selected technology. Methods are presented for both adoption of technologies within an existing OCC and for a complete OCC replacement, including human factors considerations for OCC design and setup.« less

  14. Fuel Cells for Backup Power in Telecommunications Facilities (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2009-04-01

    Telecommunications providers rely on backup power to maintain a constant power supply, to prevent power outages, and to ensure the operability of cell towers, equipment, and networks. The backup power supply that best meets these objectives is fuel cell technology.

  15. What Happened to Our Environment and Mental Health as a Result of Hurricane Sandy?

    PubMed

    Lin, Shao; Lu, Yi; Justino, John; Dong, Guanghui; Lauper, Ursula

    2016-06-01

    This study describes findings of the impacts of Hurricane Sandy on environmental factors including power outages, air quality, water quality, and weather factors and how these affected mental health during the hurricane. An ecological study was conducted at the county level to describe changes in environmental factors-especially power outages-and their relationships to emergency department (ED) visits for mental health problems by use of a Poisson regression model. We found that many environmental hazards occurred as co-exposures during Hurricane Sandy in addition to flooding. Mental health ED visits corresponded with the peak of maximum daily power blackouts, with a 3-day lag, and were positively associated with power blackouts in Bronx (prevalence ratio [PR]: 8.82, 95% confidence interval [CI]: 1.27-61.42) and Queens (PR: 2.47, 95% CI: 1.05-5.82) counties. A possible dose-response relationship was found between the quantile of maximum blackout percentage and the risk of mental health in the Bronx. We found that multiple co-environmental hazards occurred during Hurricane Sandy, especially power blackouts that mediated this disaster's impacts. The effects of power outage on mental health had large geographic variations and were substantial, especially in communities with low sociodemographic status. These findings may provide new insights for future disaster response and preparedness efforts. (Disaster Med Public Health Preparedness. 2016;10:314-319).

  16. Development of an Agent Based Model to Estimate and Reduce Time to Restoration of Storm Induced Power Outages

    NASA Astrophysics Data System (ADS)

    Walsh, T.; Layton, T.; Mellor, J. E.

    2017-12-01

    Storm damage to the electric grid impacts 23 million electric utility customers and costs US consumers $119 billion annually. Current restoration techniques rely on the past experiences of emergency managers. There are few analytical simulation and prediction tools available for utility managers to optimize storm recovery and decrease consumer cost, lost revenue and restoration time. We developed an agent based model (ABM) for storm recovery in Connecticut. An ABM is a computer modeling technique comprised of agents who are given certain behavioral rules and operate in a given environment. It allows the user to simulate complex systems by varying user-defined parameters to study emergent, unpredicted behavior. The ABM incorporates the road network and electric utility grid for the state, is validated using actual storm event recoveries and utilizes the Dijkstra routing algorithm to determine the best path for repair crews to travel between outages. The ABM has benefits for both researchers and utility managers. It can simulate complex system dynamics, rank variable importance, find tipping points that could significantly reduce restoration time or costs and test a broad range of scenarios. It is a modular, scalable and adaptable technique that can simulate scenarios in silico to inform emergency managers before and during storm events to optimize restoration strategies and better manage expectations of when power will be restored. Results indicate that total restoration time is strongly dependent on the number of crews. However, there is a threshold whereby more crews will not decrease the restoration time, which depends on the total number of outages. The addition of outside crews is more beneficial for storms with a higher number of outages. The time to restoration increases linearly with increasing repair time, while the travel speed has little overall effect on total restoration time. Crews traveling to the nearest outage reduces the total restoration time, while crews going to the outage with most customers affected increases the overall restoration time but more quickly decreases the customers remaining without power. This model can give utility company managers the ability to optimize their restoration strategies before or during a storm event to reduce restoration times and costs.

  17. SpalLoop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabau, Adrian; Wright, Ian

    Boiler tubes in steam power plants experience tube blockages due to exfoliation of oxide grown on the inner side of the tubes. In extreme cases, significant tube blockages can lead to forced power plant outages. It is thus desired to predict through modeling the amount of tube blockage in order to inform power plant operators of possible forced outages. SpalLoop solves for the stress-strain equations in an axisymmetric geometry, tracking the stress/strain evolution during boiler operation including outages for the entire boiler tube length. At each operational outage, i.e., temperature excursions down to room temperature, the amount of exfoliated areamore » for the entire tube loop is estimated the amount of tube blockage is predicted based assumed blockage geometry and site. The SpaLLoop code contains modules developed for oxide growth, stress analysis, tube loop geometry, blockage area by taking into account the following phenomena and features, (a) Plant operation schedule with periodic alternate full-load and partial-load regimes and shut-downs, i.e., temperature excursions from high-load to room temperature, (b) axisymmetric formulation for cylindrical tubes, (c) oxide growth in a temperature gradient with multiple oxide layers, (d) geometry of a boiler tube with a single tube loop or two tube loops, (e) temperature variation along the tube length based on hot gas temperature distribution outside the tube and inlet steam temperature, (f) non-uniform oxide growth along the tube length according to the local steam tube temperature, (g) exfoliated area module: at each operational outage considered, the amount of exfoliated area and exfoliated volume along the tube is estimated, (h) blockage module: at each operational outage considered, the exfoliated volume/mass for each tube loop is estimated from which the amount of tube blockage is predicted based on given blockage geometry (length, location, and geometry). The computer program is written in FORTRAN90. Its modular structure was sought for allowing the best flexibility in updating the program by implementing new constitutive equations due to availability of new material property data and/or new physical phenomena.« less

  18. Characterization of Nighttime Light Variability Over the Southeastern United States

    NASA Technical Reports Server (NTRS)

    Cole, Tony A.; Molthan, Andrew L.; Schultz, Lori A.

    2016-01-01

    City lights provide indications of human activity at night. Nighttime satellite imagery offers daily snapshots of this activity. With calibrated, science-quality imagery, long-term monitoring can also be achieved. The degree to which city lights fluctuate, however, is not well known. For the application of detecting power outages, this degree of variability is crucial for assessing reductions to city lights based on historical trends. Eight southeastern U.S. cities are analyzed to understand the relationship between emission variability and several population centers. A preliminary, example case power outage study is also discussed as a transition into future work.

  19. Energy Efficiency Maximization for WSNs with Simultaneous Wireless Information and Power Transfer

    PubMed Central

    Yu, Hongyan; Zhang, Yongqiang; Yang, Yuanyuan; Ji, Luyue

    2017-01-01

    Recently, the simultaneous wireless information and power transfer (SWIPT) technique has been regarded as a promising approach to enhance performance of wireless sensor networks with limited energy supply. However, from a green communication perspective, energy efficiency optimization for SWIPT system design has not been investigated in Wireless Rechargeable Sensor Networks (WRSNs). In this paper, we consider the tradeoffs between energy efficiency and three factors including spectral efficiency, the transmit power and outage target rate for two different modes, i.e., power splitting (PS) and time switching modes (TS), at the receiver. Moreover, we formulate the energy efficiency maximization problem subject to the constraints of minimum Quality of Service (QoS), minimum harvested energy and maximum transmission power as non-convex optimization problem. In particular, we focus on optimizing power control and power allocation policy in PS and TS modes to maximize energy efficiency of data transmission. For PS and TS modes, we propose the corresponding algorithm to characterize a non-convex optimization problem that takes into account the circuit power consumption and the harvested energy. By exploiting nonlinear fractional programming and Lagrangian dual decomposition, we propose suboptimal iterative algorithms to obtain the solutions of non-convex optimization problems. Furthermore, we derive the outage probability and effective throughput from the scenarios that the transmitter does not or partially know the channel state information (CSI) of the receiver. Simulation results illustrate that the proposed optimal iterative algorithm can achieve optimal solutions within a small number of iterations and various tradeoffs between energy efficiency and spectral efficiency, transmit power and outage target rate, respectively. PMID:28820496

  20. Energy Efficiency Maximization for WSNs with Simultaneous Wireless Information and Power Transfer.

    PubMed

    Yu, Hongyan; Zhang, Yongqiang; Guo, Songtao; Yang, Yuanyuan; Ji, Luyue

    2017-08-18

    Recently, the simultaneous wireless information and power transfer (SWIPT) technique has been regarded as a promising approach to enhance performance of wireless sensor networks with limited energy supply. However, from a green communication perspective, energy efficiency optimization for SWIPT system design has not been investigated in Wireless Rechargeable Sensor Networks (WRSNs). In this paper, we consider the tradeoffs between energy efficiency and three factors including spectral efficiency, the transmit power and outage target rate for two different modes, i.e., power splitting (PS) and time switching modes (TS), at the receiver. Moreover, we formulate the energy efficiency maximization problem subject to the constraints of minimum Quality of Service (QoS), minimum harvested energy and maximum transmission power as non-convex optimization problem. In particular, we focus on optimizing power control and power allocation policy in PS and TS modes to maximize energy efficiency of data transmission. For PS and TS modes, we propose the corresponding algorithm to characterize a non-convex optimization problem that takes into account the circuit power consumption and the harvested energy. By exploiting nonlinear fractional programming and Lagrangian dual decomposition, we propose suboptimal iterative algorithms to obtain the solutions of non-convex optimization problems. Furthermore, we derive the outage probability and effective throughput from the scenarios that the transmitter does not or partially know the channel state information (CSI) of the receiver. Simulation results illustrate that the proposed optimal iterative algorithm can achieve optimal solutions within a small number of iterations and various tradeoffs between energy efficiency and spectral efficiency, transmit power and outage target rate, respectively.

  1. Olkiluoto 1 and 2 - Plant efficiency improvement and lifetime extension-project (PELE) implemented during outages 2010 and 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kosonen, M.; Hakola, M.

    2012-07-01

    Teollisuuden Voima Oyj (TVO) is a non-listed public company founded in 1969 to produce electricity for its stakeholders. TVO is the operator of the Olkiluoto nuclear power plant. TVO follows the principle of continuous improvement in the operation and maintenance of the Olkiluoto plant units. The PELE project (Plant Efficiency Improvement and Lifetime Extension), mainly completed during the annual outages in 2010 and 2011, and forms one part of the systematic development of Olkiluoto units. TVO maintains a long-term development program that aims at systematically modernizing the plant unit systems and equipment based on the latest technology. According to themore » program, the Olkiluoto 1 and Olkiluoto 2 plant units are constantly renovated with the intention of keeping them safe and reliable, The aim of the modernization projects is to improve the safety, reliability, and performance of the plant units. PELE project at Olkiluoto 1 was done in 2010 and at Olkiluoto 2 in 2011. The outage length of Olkiluoto 1 was 26 d 12 h 4 min and Olkiluoto 2 outage length was 28 d 23 h 46 min. (Normal service-outage is about 14 days including refueling and refueling-outage length is about seven days. See figure 1) The PELE project consisted of several single projects collected into one for coordinated project management. Some of the main projects were as follows: - Low pressure turbines: rotor, stator vane, casing and turbine instrumentation replacement. - Replacement of Condenser Cooling Water (later called seawater pumps) pumps - Replacement of inner isolation valves on the main steam lines. - Generator and the generator cooling system replacement. - Low voltage switchgear replacement. This project will continue during future outages. PELE was a success. 100 TVO employees and 1500 subcontractor employees participated in the project. The execution of the PELE projects went extremely well during the outages. The replacement of the low pressure turbines and seawater pumps improved the efficiency of the plant units, and a power increase of nearly 20 MW was achieved at both plant units. PELE wonderfully manifests one of the strategic goals of our company; developing the competence of our in-house personnel by working in projects. (authors)« less

  2. Restoring Faith in the bulk-power system: an early assessment of mandatory reliability standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAllister, Levi; Dawson, Kelly L.

    2010-03-15

    The driving force underlying creation of mandatory reliability standards was the prevention of widespread outages, such as those that occurred in 1965, 1977 and 2003. So far, no similar outage has occurred when an entity is in full compliance with the standards, and NERC and FERC have demonstrated that they will actively enforce compliance while aggressively pursuing entities alleged to be non-compliant. (author)

  3. VERDE Analytic Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2008-01-15

    The Verde Analytic Modules permit the user to ingest openly available data feeds about phenomenology (storm tracks, wind, precipitation, earthquake, wildfires, and similar natural and manmade power grid disruptions and forecast power outages, restoration times, customers outaged, and key facilities that will lose power. Damage areas are predicted using historic damage criteria of the affected area. The modules use a cellular automata approach to estimating the distribution circuits assigned to geo-located substations. Population estimates served within the service areas are located within 1 km grid cells and converted to customer counts by conversion through demographic estimation of households and commercialmore » firms within the population cells. Restoration times are estimated by agent-based simulation of restoration crews working according to utility published prioritization calibrated by historic performance.« less

  4. Impact of Distributed Energy Resources on the Reliability of Critical Telecommunications Facilities: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, D. G.; Arent, D. J.; Johnson, L.

    2006-06-01

    This paper documents a probabilistic risk assessment of existing and alternative power supply systems at a large telecommunications office. The analysis characterizes the increase in the reliability of power supply through the use of two alternative power configurations. Failures in the power systems supporting major telecommunications service nodes are a main contributor to significant telecommunications outages. A logical approach to improving the robustness of telecommunication facilities is to increase the depth and breadth of technologies available to restore power during power outages. Distributed energy resources such as fuel cells and gas turbines could provide additional on-site electric power sources tomore » provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less

  5. A Study of the Impact of Peak Demand on Increasing Vulnerability of Cascading Failures to Extreme Contingency Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vyakaranam, Bharat GNVSR; Vallem, Mallikarjuna R.; Nguyen, Tony B.

    The vulnerability of large power systems to cascading failures and major blackouts has become evident since the Northeast blackout in 1965. Based on analyses of the series of cascading blackouts in the past decade, the research community realized the urgent need to develop better methods, tools, and practices for performing cascading-outage analysis and for evaluating mitigations that are easily accessible by utility planning engineers. PNNL has developed the Dynamic Contingency Analysis Tool (DCAT) as an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power planning engineers to assess the impact and likelihoodmore » of extreme contingencies and potential cascading events across their systems and interconnections. DCAT analysis will help identify potential vulnerabilities and allow study of mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. Using the DCAT capability, we examined the impacts of various load conditions to identify situations in which the power grid may encounter cascading outages that could lead to potential blackouts. This paper describes the usefulness of the DCAT tool and how it helps to understand potential impacts of load demand on cascading failures on the power system.« less

  6. Placement of Synchronized Measurements for Power System Observability during Cascaded Outages

    NASA Astrophysics Data System (ADS)

    Thirugnanasambandam, Venkatesh; Jain, Trapti

    2017-11-01

    Cascaded outages often result in power system islanding followed by a blackout and therefore considered as a severe disturbance. Maintaining the observability of each island may help in taking proper control actions to preserve the stability of individual islands thus, averting system collapse. With this intent, a strategy for placement of synchronized measurements, which can be obtained from phasor measurement units (PMU), has been proposed in this paper to keep the system observable during cascaded outages also. Since, all the cascaded failures may not lead to islanding situations, therefore, failures leading to islanding as well as non-islanding situations have been considered. A topology based algorithm has been developed to identify the islanding/non-islanding condition created by a particular cascaded event. Additional contingencies such as single line loss and single PMU failure have also been considered after the occurrence of cascaded events. The proposed method is further extended to incorporate the measurement redundancy, which is desirable for a reliable state estimation. The proposed scheme is tested on IEEE 14-bus, IEEE 30-bus and a practical Indian 246-bus networks. The numerical results ensure the observability of the power system under system intact as well as during cascaded islanding and non-islanding disturbances.

  7. Trusted information sources used during and after Superstorm Sandy: TV and radio were used more often than social media

    PubMed Central

    Burger, Joanna; Gochfeld, Michael; Jeitner, Christian; Pittfield, Taryn; Donio, Mark

    2015-01-01

    Health and safety professionals, and the public, are interested in the best methods of providing timely information about disasters. The objective of this study was to examine information sources used for Superstorm Sandy with respect to the storm, evacuation routes, shelters, safety, and health issues. Respondents in Central New Jersey and Jersey Shore communities were differentially impacted by the storm. Jersey shore respondents had higher evacuation rates (47 % vs 13 %), higher flood waters in homes, longer power outages (average 23 vs 6 days), and longer periods without internet (29 vs 6 days). Electricity outages disrupted both sources and receivers of communication. Both groups obtained most of their information regarding safety from television, radio, friends and web/email. Information sources on health varied by location, with central Jersey respondents using mainly TV and the web, and Jersey shore respondents obtaining health information from the radio, and TV (before the storm). For information on evacuation routes, Jersey shore respondents obtained information from many sources, while central Jersey respondents obtained it from TV. Information on mold was largely obtained from friends and the web, since mold issues were dealt with several weeks after Sandy. The reliance on traditional sources of information (TV, radio, friends) found in this study suggests that the extreme power outages rendered web, cell phones, and social media on cell phones less usable, and suggests the need for an integrated communication strategy with redundancies that takes into account prolonged power outages over large geographical areas. PMID:24279815

  8. Trusted information sources used during and after Superstorm Sandy: TV and radio were used more often than social media.

    PubMed

    Burger, Joanna; Gochfeld, Michael; Jeitner, Christian; Pittfield, Taryn; Donio, Mark

    2013-01-01

    Health and safety professionals and the public are interested in the best methods of providing timely information about disasters. The objective of this study was to examine information sources used for Superstorm Sandy with respect to the storm, evacuation routes, shelters, safety, and health issues. Respondents in central New Jersey and Jersey shore communities were differentially impacted by the storm. Jersey shore respondents had higher evacuation rates (47% vs. 13%), higher flood waters in homes, longer power outages (average 23 vs. 6 d), and longer periods without Internet (29 vs. 6 d). Electricity outages disrupted both sources and receivers of communication. Both groups obtained most of their information regarding safety from television, radio, friends, and Web/e-mail. Information sources on health varied by location, with central Jersey respondents using mainly TV and the Web, and Jersey shore respondents obtaining health information from the radio and TV (before the storm). For information on evacuation routes, Jersey shore respondents obtained information from many sources, while central Jersey respondents obtained it from TV. Information on mold was largely obtained from friends and the Web, since mold issues were dealt with several weeks after Sandy. The reliance on traditional sources of information (TV, radio, friends) found in this study suggests that the extreme power outages rendered Web, cell phones, and social media on cell phones less usable, and suggests the need for an integrated communication strategy with redundancies that takes into account prolonged power outages over large geographical areas.

  9. Computer Power. Part 2: Electrical Power Problems and Their Amelioration.

    ERIC Educational Resources Information Center

    Price, Bennett J.

    1989-01-01

    Describes electrical power problems that affect computer users, including spikes, sags, outages, noise, frequency variations, and static electricity. Ways in which these problems may be diagnosed and cured are discussed. Sidebars consider transformers; power distribution units; surge currents/linear and non-linear loads; and sizing the power…

  10. An MBS-Assisted Femtocell Transmit Power Control Scheme with Mobile User QoS Guarantee in 2-Tier Heterogeneous Femtocell Networks

    PubMed Central

    Yang, Chih-Cheng; Sheu, Shiann-Tsong

    2013-01-01

    This study investigates how to adjust the transmit power of femto base station (FBS) to mitigate interference problems between the FBSs and mobile users (MUs) in the 2-tier heterogeneous femtocell networks. A common baseline of deploying the FBS to increase the indoor access bandwidth requires that the FBS operation will not affect outdoor MUs operation with their quality-of-service (QoS) requirements. To tackle this technical problem, an FBS transmit power adjustment (FTPA) algorithm is proposed to adjust the FBS transmit power (FTP) to avoid unwanted cochannel interference (CCI) with the neighboring MUs in downlink transmission. FTPA reduces the FTP to serve its femto users (FUs) according to the QoS requirements of the nearest neighboring MUs to the FBS so that the MU QoS requirement is guaranteed. Simulation results demonstrate that FTPA can achieve a low MU outage probability as well as serve FUs without violating the MU QoS requirements. Simulation results also reveal that FTPA has better performance on voice and video services which are the major trend of future multimedia communication in the NGN. PMID:24391461

  11. An MBS-assisted femtocell transmit power control scheme with mobile user QoS guarantee in 2-tier heterogeneous femtocell networks.

    PubMed

    Chen, Jenhui; Yang, Chih-Cheng; Sheu, Shiann-Tsong

    2013-01-01

    This study investigates how to adjust the transmit power of femto base station (FBS) to mitigate interference problems between the FBSs and mobile users (MUs) in the 2-tier heterogeneous femtocell networks. A common baseline of deploying the FBS to increase the indoor access bandwidth requires that the FBS operation will not affect outdoor MUs operation with their quality-of-service (QoS) requirements. To tackle this technical problem, an FBS transmit power adjustment (FTPA) algorithm is proposed to adjust the FBS transmit power (FTP) to avoid unwanted cochannel interference (CCI) with the neighboring MUs in downlink transmission. FTPA reduces the FTP to serve its femto users (FUs) according to the QoS requirements of the nearest neighboring MUs to the FBS so that the MU QoS requirement is guaranteed. Simulation results demonstrate that FTPA can achieve a low MU outage probability as well as serve FUs without violating the MU QoS requirements. Simulation results also reveal that FTPA has better performance on voice and video services which are the major trend of future multimedia communication in the NGN.

  12. Advanced Outage and Control Center: Strategies for Nuclear Plant Outage Work Status Capabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory Weatherby

    The research effort is a part of the Light Water Reactor Sustainability (LWRS) Program. LWRS is a research and development program sponsored by the Department of Energy, performed in close collaboration with industry to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. The LWRS Program serves to help the US nuclear industry adopt new technologies and engineering solutions that facilitate the continued safe operation of the plants and extension of the current operating licenses. The Outage Control Center (OCC) Pilot Project was directed at carrying out the applied researchmore » for development and pilot of technology designed to enhance safe outage and maintenance operations, improve human performance and reliability, increase overall operational efficiency, and improve plant status control. Plant outage management is a high priority concern for the nuclear industry from cost and safety perspectives. Unfortunately, many of the underlying technologies supporting outage control are the same as those used in the 1980’s. They depend heavily upon large teams of staff, multiple work and coordination locations, and manual administrative actions that require large amounts of paper. Previous work in human reliability analysis suggests that many repetitive tasks, including paper work tasks, may have a failure rate of 1.0E-3 or higher (Gertman, 1996). With between 10,000 and 45,000 subtasks being performed during an outage (Gomes, 1996), the opportunity for human error of some consequence is a realistic concern. Although a number of factors exist that can make these errors recoverable, reducing and effectively coordinating the sheer number of tasks to be performed, particularly those that are error prone, has the potential to enhance outage efficiency and safety. Additionally, outage management requires precise coordination of work groups that do not always share similar objectives. Outage managers are concerned with schedule and cost, union workers are concerned with performing work that is commensurate with their trade, and support functions (safety, quality assurance, and radiological controls, etc.) are concerned with performing the work within the plants controls and procedures. Approaches to outage management should be designed to increase the active participation of work groups and managers in making decisions that closed the gap between competing objectives and the potential for error and process inefficiency.« less

  13. AUTOMATED UTILITY SERVICE AREA ASSESSMENT UNDER EMERGENCY CONDITIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. TOOLE; S. LINGER

    2001-01-01

    All electric utilities serve power to their customers through a variety of functional levels, notably substations. The majority of these components consist of distribution substations operating at lower voltages while a small fraction are transmission substations. There is an associated geographical area that encompasses customers who are served, defined as the service area. Analysis of substation service areas is greatly complicated by several factors: distribution networks are often highly interconnected which allows a multitude of possible switching operations; also, utilities dynamically alter the network topology in order to respond to emergency events. As a result, the service area for amore » substation can change radically. A utility will generally attempt to minimize the number of customers outaged by switching effected loads to alternate substations. In this manner, all or a portion of a disabled substation's load may be served by one or more adjacent substations. This paper describes a suite of analytical tools developed at Los Alamos National Laboratory (LANL), which address the problem of determining how a utility might respond to such emergency events. The estimated outage areas derived using the tools are overlaid onto other geographical and electrical layers in a geographic information system (GIS) software application. The effects of a power outage on a population, other infrastructures, or other physical features, can be inferred by the proximity of these features to the estimated outage area.« less

  14. Cluster Cooperation in Wireless-Powered Sensor Networks: Modeling and Performance Analysis.

    PubMed

    Zhang, Chao; Zhang, Pengcheng; Zhang, Weizhan

    2017-09-27

    A wireless-powered sensor network (WPSN) consisting of one hybrid access point (HAP), a near cluster and the corresponding far cluster is investigated in this paper. These sensors are wireless-powered and they transmit information by consuming the harvested energy from signal ejected by the HAP. Sensors are able to harvest energy as well as store the harvested energy. We propose that if sensors in near cluster do not have their own information to transmit, acting as relays, they can help the sensors in a far cluster to forward information to the HAP in an amplify-and-forward (AF) manner. We use a finite Markov chain to model the dynamic variation process of the relay battery, and give a general analyzing model for WPSN with cluster cooperation. Though the model, we deduce the closed-form expression for the outage probability as the metric of this network. Finally, simulation results validate the start point of designing this paper and correctness of theoretical analysis and show how parameters have an effect on system performance. Moreover, it is also known that the outage probability of sensors in far cluster can be drastically reduced without sacrificing the performance of sensors in near cluster if the transmit power of HAP is fairly high. Furthermore, in the aspect of outage performance of far cluster, the proposed scheme significantly outperforms the direct transmission scheme without cooperation.

  15. Cluster Cooperation in Wireless-Powered Sensor Networks: Modeling and Performance Analysis

    PubMed Central

    Zhang, Chao; Zhang, Pengcheng; Zhang, Weizhan

    2017-01-01

    A wireless-powered sensor network (WPSN) consisting of one hybrid access point (HAP), a near cluster and the corresponding far cluster is investigated in this paper. These sensors are wireless-powered and they transmit information by consuming the harvested energy from signal ejected by the HAP. Sensors are able to harvest energy as well as store the harvested energy. We propose that if sensors in near cluster do not have their own information to transmit, acting as relays, they can help the sensors in a far cluster to forward information to the HAP in an amplify-and-forward (AF) manner. We use a finite Markov chain to model the dynamic variation process of the relay battery, and give a general analyzing model for WPSN with cluster cooperation. Though the model, we deduce the closed-form expression for the outage probability as the metric of this network. Finally, simulation results validate the start point of designing this paper and correctness of theoretical analysis and show how parameters have an effect on system performance. Moreover, it is also known that the outage probability of sensors in far cluster can be drastically reduced without sacrificing the performance of sensors in near cluster if the transmit power of HAP is fairly high. Furthermore, in the aspect of outage performance of far cluster, the proposed scheme significantly outperforms the direct transmission scheme without cooperation. PMID:28953231

  16. Bayesian wavelet PCA methodology for turbomachinery damage diagnosis under uncertainty

    NASA Astrophysics Data System (ADS)

    Xu, Shengli; Jiang, Xiaomo; Huang, Jinzhi; Yang, Shuhua; Wang, Xiaofang

    2016-12-01

    Centrifugal compressor often suffers various defects such as impeller cracking, resulting in forced outage of the total plant. Damage diagnostics and condition monitoring of such a turbomachinery system has become an increasingly important and powerful tool to prevent potential failure in components and reduce unplanned forced outage and further maintenance costs, while improving reliability, availability and maintainability of a turbomachinery system. This paper presents a probabilistic signal processing methodology for damage diagnostics using multiple time history data collected from different locations of a turbomachine, considering data uncertainty and multivariate correlation. The proposed methodology is based on the integration of three advanced state-of-the-art data mining techniques: discrete wavelet packet transform, Bayesian hypothesis testing, and probabilistic principal component analysis. The multiresolution wavelet analysis approach is employed to decompose a time series signal into different levels of wavelet coefficients. These coefficients represent multiple time-frequency resolutions of a signal. Bayesian hypothesis testing is then applied to each level of wavelet coefficient to remove possible imperfections. The ratio of posterior odds Bayesian approach provides a direct means to assess whether there is imperfection in the decomposed coefficients, thus avoiding over-denoising. Power spectral density estimated by the Welch method is utilized to evaluate the effectiveness of Bayesian wavelet cleansing method. Furthermore, the probabilistic principal component analysis approach is developed to reduce dimensionality of multiple time series and to address multivariate correlation and data uncertainty for damage diagnostics. The proposed methodology and generalized framework is demonstrated with a set of sensor data collected from a real-world centrifugal compressor with impeller cracks, through both time series and contour analyses of vibration signal and principal components.

  17. Impact of distributed energy resources on the reliability of a critical telecommunications facility.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, David; Zuffranieri, Jason V.; Atcitty, Christopher B.

    2006-03-01

    This report documents a probabilistic risk assessment of an existing power supply system at a large telecommunications office. The focus is on characterizing the increase in the reliability of power supply through the use of two alternative power configurations. Telecommunications has been identified by the Department of Homeland Security as a critical infrastructure to the United States. Failures in the power systems supporting major telecommunications service nodes are a main contributor to major telecommunications outages. A logical approach to improve the robustness of telecommunication facilities would be to increase the depth and breadth of technologies available to restore power inmore » the face of power outages. Distributed energy resources such as fuel cells and gas turbines could provide one more onsite electric power source to provide backup power, if batteries and diesel generators fail. The analysis is based on a hierarchical Bayesian approach and focuses on the failure probability associated with each of three possible facility configurations, along with assessment of the uncertainty or confidence level in the probability of failure. A risk-based characterization of final best configuration is presented.« less

  18. Critical Assessment of the Foundations of Power Transmission and Distribution Reliability Metrics and Standards.

    PubMed

    Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan

    2016-01-01

    The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.

  19. Guidelines for traffic signal energy back\\0x2010up systems : final report.

    DOT National Transportation Integrated Search

    2009-07-01

    Power outages affect traffic signalized intersections, leading to potentially serious problems. Current practices of responding to power failures are very basic, ranging from do nothing to installing portable generators. The purpose of this res...

  20. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

    PubMed Central

    Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.

    2017-01-01

    Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. PMID:28364935

  1. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    PubMed

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published by Elsevier Ltd.

  2. Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roussel, G.

    1997-02-01

    Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, allmore » the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena.« less

  3. Chemical Safety Alert: Chemical Accidents from Electric Power Outages

    EPA Pesticide Factsheets

    Incident data from the National Response Center (NRC) shows that during 2000 there were about 240 chemical releases reported due to an electric power interruption, as well as resumption/restart; only a few were related to planned rolling blackouts.

  4. Creating Productive Roadways : Developing an Advanced Energy Production, Storage, and Distribution System

    DOT National Transportation Integrated Search

    2013-05-01

    Renewable electric power production could reduce highway maintenance and operating costs and provide backup for critical systems during power outages. Using the public right-of-way and roadway infrastructure as a source for energy production, storage...

  5. Outage Performance Analysis of Relay Selection Schemes in Wireless Energy Harvesting Cooperative Networks over Non-Identical Rayleigh Fading Channels †

    PubMed Central

    Do, Nhu Tri; Bao, Vo Nguyen Quoc; An, Beongku

    2016-01-01

    In this paper, we study relay selection in decode-and-forward wireless energy harvesting cooperative networks. In contrast to conventional cooperative networks, the relays harvest energy from the source’s radio-frequency radiation and then use that energy to forward the source information. Considering power splitting receiver architecture used at relays to harvest energy, we are concerned with the performance of two popular relay selection schemes, namely, partial relay selection (PRS) scheme and optimal relay selection (ORS) scheme. In particular, we analyze the system performance in terms of outage probability (OP) over independent and non-identical (i.n.i.d.) Rayleigh fading channels. We derive the closed-form approximations for the system outage probabilities of both schemes and validate the analysis by the Monte-Carlo simulation. The numerical results provide comprehensive performance comparison between the PRS and ORS schemes and reveal the effect of wireless energy harvesting on the outage performances of both schemes. Additionally, we also show the advantages and drawbacks of the wireless energy harvesting cooperative networks and compare to the conventional cooperative networks. PMID:26927119

  6. Outage Performance Analysis of Relay Selection Schemes in Wireless Energy Harvesting Cooperative Networks over Non-Identical Rayleigh Fading Channels.

    PubMed

    Do, Nhu Tri; Bao, Vo Nguyen Quoc; An, Beongku

    2016-02-26

    In this paper, we study relay selection in decode-and-forward wireless energy harvesting cooperative networks. In contrast to conventional cooperative networks, the relays harvest energy from the source's radio-frequency radiation and then use that energy to forward the source information. Considering power splitting receiver architecture used at relays to harvest energy, we are concerned with the performance of two popular relay selection schemes, namely, partial relay selection (PRS) scheme and optimal relay selection (ORS) scheme. In particular, we analyze the system performance in terms of outage probability (OP) over independent and non-identical (i.n.i.d.) Rayleigh fading channels. We derive the closed-form approximations for the system outage probabilities of both schemes and validate the analysis by the Monte-Carlo simulation. The numerical results provide comprehensive performance comparison between the PRS and ORS schemes and reveal the effect of wireless energy harvesting on the outage performances of both schemes. Additionally, we also show the advantages and drawbacks of the wireless energy harvesting cooperative networks and compare to the conventional cooperative networks.

  7. Improving Distribution Resiliency with Microgrids and State and Parameter Estimation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuffner, Francis K.; Williams, Tess L.; Schneider, Kevin P.

    Modern society relies on low-cost reliable electrical power, both to maintain industry, as well as provide basic social services to the populace. When major disturbances occur, such as Hurricane Katrina or Hurricane Sandy, the nation’s electrical infrastructure can experience significant outages. To help prevent the spread of these outages, as well as facilitating faster restoration after an outage, various aspects of improving the resiliency of the power system are needed. Two such approaches are breaking the system into smaller microgrid sections, and to have improved insight into the operations to detect failures or mis-operations before they become critical. Breaking themore » system into smaller sections of microgrid islands, power can be maintained in smaller areas where distribution generation and energy storage resources are still available, but bulk power generation is no longer connected. Additionally, microgrid systems can maintain service to local pockets of customers when there has been extensive damage to the local distribution system. However, microgrids are grid connected a majority of the time and implementing and operating a microgrid is much different than when islanded. This report discusses work conducted by the Pacific Northwest National Laboratory that developed improvements for simulation tools to capture the characteristics of microgrids and how they can be used to develop new operational strategies. These operational strategies reduce the cost of microgrid operation and increase the reliability and resilience of the nation’s electricity infrastructure. In addition to the ability to break the system into microgrids, improved observability into the state of the distribution grid can make the power system more resilient. State estimation on the transmission system already provides great insight into grid operations and detecting abnormal conditions by leveraging existing measurements. These transmission-level approaches are expanded to using advanced metering infrastructure and other distribution-level measurements to create a three-phase, unbalanced distribution state estimation approach. With distribution-level state estimation, the grid can be operated more efficiently, and outages or equipment failures can be caught faster, improving the overall resilience and reliability of the grid.« less

  8. Index-based reactive power compensation scheme for voltage regulation

    NASA Astrophysics Data System (ADS)

    Dike, Damian Obioma

    2008-10-01

    Increasing demand for electrical power arising from deregulation and the restrictions posed to the construction of new transmission lines by environment, socioeconomic, and political issues had led to higher grid loading. Consequently, voltage instability has become a major concern, and reactive power support is vital to enhance transmission grid performance. Improved reactive power support to distressed grid is possible through the application of relatively unfamiliar emerging technologies of "Flexible AC Transmission Systems (FACTS)" devices and "Distributed Energy Resources (DERS)." In addition to these infrastructure issues, a lack of situational awareness by system operators can cause major power outages as evidenced by the August 14, 2003 widespread North American blackout. This and many other recent major outages have highlighted the inadequacies of existing power system indexes. In this work, a novel "Index-based reactive compensation scheme" appropriate for both on-line and off-line computation of grid status has been developed. A new voltage stability index (Ls-index) suitable for long transmission lines was developed, simulated, and compared to the existing two-machine modeled L-index. This showed the effect of long distance power wheeling amongst regional transmission organizations. The dissertation further provided models for index modulated voltage source converters (VSC) and index-based load flow analysis of both FACTS and microgrid interconnected power systems using the Newton-Raphson's load flow model incorporated with multi-FACTS devices. The developed package has been made user-friendly through the embodiment of interactive graphical user interface and implemented on the IEEE 14, 30, and 300 bus systems. The results showed reactive compensation has system wide-effect, provided readily accessible system status indicators, ensured seamless DERs interconnection through new islanding modes and enhanced VSC utilization. These outcomes may contribute to optimal utilization of compensation devices and available transfer capability as well as reduce system outages through better regulation of power operating voltages.

  9. Code Development and Assessment for Reactor Outage Thermal-Hydraulic and Safety Analysis - Midloop Operation with Loss of Residual Heat Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Thomas K.S.; Ko, F.-K

    Although only a few percent of residual power remains during plant outages, the associated risk of core uncovery and corresponding fuel overheating has been identified to be relatively high, particularly under midloop operation (MLO) in pressurized water reactors. However, to analyze the system behavior during outages, the tools currently available, such as RELAP5, RETRAN, etc., cannot easily perform the task. Therefore, a medium-sized program aiming at reactor outage simulation and evaluation, such as MLO with the loss of residual heat removal (RHR), was developed. All important thermal-hydraulic processes involved during MLO with the loss of RHR will be properly simulatedmore » by the newly developed reactor outage simulation and evaluation (ROSE) code. Important processes during MLO with loss of RHR involve a pressurizer insurge caused by the hot-leg flooding, reflux condensation, liquid holdup inside the steam generator, loop-seal clearance, core-level depression, etc. Since the accuracy of the pressure distribution from the classical nodal momentum approach will be degraded when the system is stratified and under atmospheric pressure, the two-region approach with a modified two-fluid model will be the theoretical basis of the new program to analyze the nuclear steam supply system during plant outages. To verify the analytical model in the first step, posttest calculations against the closed integral midloop experiments with loss of RHR were performed. The excellent simulation capacity of the ROSE code against the Institute of Nuclear Energy Research Integral System Test Facility (IIST) test data is demonstrated.« less

  10. 77 FR 28595 - Sunshine Act Meeting Notice

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-15

    ...-Southern California Outages on September 8, 2011. Electric E-1 RM10-23-001 Transmission Planning and Cost... Communications Trustees of the City of Muscatine, Iowa; Central Minnesota Municipal Power Agency; City of Columbia, Missouri, Water & Light Company; City Water, Light & Power (Springfield, Illinois); Dairyland...

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    The focus of the May-June issue is on outage management and health physics. Major articles include: Outage optimization initiatives, by George B. Beam, AREVA NP, Inc.; New plant based on excellent track records, by Jim Scarola, Progress Energy; Meeting customer needs and providing environmental benefits, by Peter S. Hastings, Duke Energy; Plants with 3-D design, by Jack A. Bailey, Tennessee Valley Authority; and Highest quality with exceptional planning, by Jason A. Walls, Duke Energy. Industry innovation articles include: Integrated exposure reduction plan, by Ed Wolfe, Exelon; Performance-based radiation worker training, by Joe Giuffre and Timothy Vriezerma, American Electric Power.

  12. 7 CFR 331.14 - Incident response. 6

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; bomb threats and suspicious packages; and emergencies such as fire, gas leak, explosion, power outage... information systems); severe weather and other natural disasters; workplace violence; bomb threats and...

  13. Power-line electrocution of birds (Electrocucion de Aves en Lineas Electricas en Mexico)

    Treesearch

    Patricia Manzano Fischer

    2006-01-01

    A result of rapid growth in human population and energy use, is proliferating power lines that electrocute birds, killing eagles and causing power outages. The United States was one of the first countries to recognize the significance of this problem. Suggested Practices for the Protection of Raptors on Power Lines, first published in the 1970s, has now been translated...

  14. Disparities in nuclear power plant performance in the United States and the Federal Republic of Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, K.F.; Winje, D.K.

    This report presents data comparing the performance of light water reactors in the United States and the Federal Republic of Germany (FRG). The comparisons are made for the years 1980 to 1983 and include 21 Westinghouse Pressurized Water Reactors (PWRs), 22 General Electric Boiling Water Reactors (BWRs) in the US; and 6 Kraftwerk Union (KWU) PWRs and 4 KWU BWRs in the FRG. Data on capacity losses are presented in a disaggregated form for scheduled outages, forced outages, and regulatory imposed outages. Further, within the scheduled and forced outages, the data are subdivided into losses associated with the nuclear island,more » the balance of plant, or other causes. The report also surveys a number of observations relating to the causes of discrepancies between the US and West Germany. These observations were obtained from interviews with executives and engineers in both nations, including people from vendors, utilities, regulators, and architect/engineers. These discussions are distilled into observations relating to national differences in the broad areas of economics and economic regulation, safety regulations, and technical and managerial differences. 9 refs., 2 figs., 26 tabs.« less

  15. Lights Out: Foreseeable Catastrophic Effects of Geomagnetic Storms on the North American Power Grid and How to Mitigate Them

    DTIC Science & Technology

    2011-08-21

    poultry, pork , beef, fish, and other meat products also are typically automated operations, done on electrically driven processing lines. 53 Food ...Infrastructure ..................................................... 18 Power Outage Impact on Consumables ( Food , Water, Medication...transportation, consumables ( food , water, and medication), and emergency services, are so highly dependent on reliable power supply from the grid, a

  16. Field experience with remote monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desrosiers, A.E.

    1995-03-01

    The Remote Monitoring System (RMS) is a combination of Merlin Gerin detection hardware, digital data communications hardware, and computer software from Bartlett Services, Inc. (BSI) that can improve the conduct of reactor plant operations in several areas. Using the RMS can reduce radiation exposures to radiation protection technicians (RPTs), reduce radiation exposures to plant maintenance and operations personnel, and reduce the time required to complete maintenance and inspections during outages. The number of temporary RPTs required during refueling outages can also be reduced. Data from use of the RMS at a two power plants are presented to illustrate these points.

  17. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  18. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  19. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  20. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  1. 40 CFR 76.12 - Phase I NOX compliance extension.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.12 Phase I NOX compliance extension. (a... outage. (iii) Fuel and energy balance summaries and power and other consumption requirements (including...

  2. Simulating economic effects of disruptions in the telecommunications infrastructure.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Roger Gary; Barton, Dianne Catherine; Reinert, Rhonda K.

    2004-01-01

    CommAspen is a new agent-based model for simulating the interdependent effects of market decisions and disruptions in the telecommunications infrastructure on other critical infrastructures in the U.S. economy such as banking and finance, and electric power. CommAspen extends and modifies the capabilities of Aspen-EE, an agent-based model previously developed by Sandia National Laboratories to analyze the interdependencies between the electric power system and other critical infrastructures. CommAspen has been tested on a series of scenarios in which the communications network has been disrupted, due to congestion and outages. Analysis of the scenario results indicates that communications networks simulated by themore » model behave as their counterparts do in the real world. Results also show that the model could be used to analyze the economic impact of communications congestion and outages.« less

  3. 3 CFR 8386 - Proclamation 8386 of May 26, 2009. National Hurricane Preparedness Week, 2009

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... coastal and inland communities. These powerful storms can cause heavy rainfall, high winds, tornadoes, and storm surges, which can in turn bring severe flooding, power outages, damage to homes and businesses... property of those who face advancing storms. Americans can take basic steps before a hurricane arrives. The...

  4. Providing Limited Local Electric Service During a Major Grid Outage: A First Assessment Based on Customer Willingness to Pay.

    PubMed

    Baik, Sunhee; Morgan, M Granger; Davis, Alexander L

    2018-02-01

    While they are rare, widespread blackouts of the bulk power system can result in large costs to individuals and society. If local distribution circuits remain intact, it is possible to use new technologies including smart meters, intelligent switches that can change the topology of distribution circuits, and distributed generation owned by customers and the power company, to provide limited local electric power service. Many utilities are already making investments that would make this possible. We use customers' measured willingness to pay to explore when the incremental investments needed to implement these capabilities would be justified. Under many circumstances, upgrades in advanced distribution systems could be justified for a customer charge of less than a dollar a month (plus the cost of electricity used during outages), and would be less expensive and safer than the proliferation of small portable backup generators. We also discuss issues of social equity, extreme events, and various sources of underlying uncertainty. © 2017 Society for Risk Analysis.

  5. BWR Servicing and Refueling Improvement Program: Phase I summary report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perry, D.R.

    1978-09-01

    Under the U.S. Department of Energy sponsorship, General Electric Co. (GE) undertook a study of boiling water reactor (BWR) refueling outages for the purpose of recommending the development and demonstration of critical path time savings improvements. The Tennessee Valley Authority (TVA) joined the study as a subcontractor, providing monitoring assistance and making the Browns Ferry Site available for improvement demonstrations. Agreement was also reached with Georgia Power Co., Power Authority of the State of New York, and Commonwealth Edison Co. for monitoring and data collection at Hatch 1, FitzPatrick, and Quad Cities 1 nuclear plants, respectively. The objective was tomore » identify, develop, and demonstrate improved refueling, maintenance, and inspection procedures and equipment. The improvements recommended in this study are applicable to BWR nuclear plants currently in operation as well as those in the design and construction phases. The recommendations and outage information can be used as a basis to plan and conduct the first outages of new plants and to improve the planning and facilities of currently operating plants. Many of the recommendations can readily be incorporated in plants currently in the design and construction phases as well as in the design of future plants. Many of these recommended improvements can be implemented immediately by utilities without further technical development.« less

  6. Knowledge to Action - Understanding Natural Hazards-Induced Power Outage Scenarios for Actionable Disaster Responses

    NASA Astrophysics Data System (ADS)

    Kar, B.; Robinson, C.; Koch, D. B.; Omitaomu, O.

    2017-12-01

    The Sendai Framework for Disaster Risk Reduction 2015-2030 identified the following four priorities to prevent and reduce disaster risks: i) understanding disaster risk; ii) strengthening governance to manage disaster risk; iii) investing in disaster risk reduction for resilience and; iv) enhancing disaster preparedness for effective response, and to "Build Back Better" in recovery, rehabilitation and reconstruction. While forecasting and decision making tools are in place to predict and understand future impacts of natural hazards, the knowledge to action approach that currently exists fails to provide updated information needed by decision makers to undertake response and recovery efforts following a hazard event. For instance, during a tropical storm event advisories are released every two to three hours, but manual analysis of geospatial data to determine potential impacts of the event tends to be time-consuming and a post-event process. Researchers at Oak Ridge National Laboratory have developed a Spatial Decision Support System that enables real-time analysis of storm impact based on updated advisory. A prototype of the tool that focuses on determining projected power outage areas and projected duration of outages demonstrates the feasibility of integrating science with decision making for emergency management personnel to act in real time to protect communities and reduce risk.

  7. Device Access Abstractions for Resilient Information Architecture Platform for Smart Grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubey, Abhishek; Karsai, Gabor; Volgyesi, Peter

    An open application platform distributes the intelligence and control capability to local endpoints (or nodes) reducing total network traffic, improving speed of local actions by avoiding latency, and improving reliability by reducing dependencies on numerous devices and communication interfaces. The platform must be multi-tasking and able to host multiple applications running simultaneously. Given such a system, the core functions of power grid control systems include grid state determination, low level control, fault intelligence and reconfiguration, outage intelligence, power quality measurement, remote asset monitoring, configuration management, power and energy management (including local distributed energy resources, such as wind, solar and energymore » storage) can be eventually distributed. However, making this move requires extensive regression testing of systems to prove out new technologies, such as phasor measurement units (PMU). Additionally, as the complexity of the systems increase with the inclusion of new functionality (especially at the distribution and consumer levels), hidden coupling issues becomes a challenge with possible N-way interactions known and not known by device and application developers. Therefore, it is very important to provide core abstractions that ensure uniform operational semantics across such interactions. Here in this paper, we describe the pattern for abstracting device interactions we have developed for the RIAPS platform in the context of a microgrid control application we have developed.« less

  8. Device Access Abstractions for Resilient Information Architecture Platform for Smart Grid

    DOE PAGES

    Dubey, Abhishek; Karsai, Gabor; Volgyesi, Peter; ...

    2018-06-12

    An open application platform distributes the intelligence and control capability to local endpoints (or nodes) reducing total network traffic, improving speed of local actions by avoiding latency, and improving reliability by reducing dependencies on numerous devices and communication interfaces. The platform must be multi-tasking and able to host multiple applications running simultaneously. Given such a system, the core functions of power grid control systems include grid state determination, low level control, fault intelligence and reconfiguration, outage intelligence, power quality measurement, remote asset monitoring, configuration management, power and energy management (including local distributed energy resources, such as wind, solar and energymore » storage) can be eventually distributed. However, making this move requires extensive regression testing of systems to prove out new technologies, such as phasor measurement units (PMU). Additionally, as the complexity of the systems increase with the inclusion of new functionality (especially at the distribution and consumer levels), hidden coupling issues becomes a challenge with possible N-way interactions known and not known by device and application developers. Therefore, it is very important to provide core abstractions that ensure uniform operational semantics across such interactions. Here in this paper, we describe the pattern for abstracting device interactions we have developed for the RIAPS platform in the context of a microgrid control application we have developed.« less

  9. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 5: Analysis of core damage frequency from seismic events for plant operational state 5 during a refueling outage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budnitz, R.J.; Davis, P.R.; Ravindra, M.K.

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Sandia National Laboratories studying a boiling water reactor (Grand Gulf), and the other at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1). Both the Sandia and Brookhaven projects have examined only accidents initiated by internal plant faults---so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling outage conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. Thismore » report covers the seismic analysis at Grand Gulf. All of the many systems modeling assumptions, component non-seismic failure rates, and human effort rates that were used in the internal-initiator study at Grand Gulf have been adopted here, so that the results of the study can be as comparable as possible. Both the Sandia study and this study examine only one shutdown plant operating state (POS) at Grand Gulf, namely POS 5 representing cold shutdown during a refueling outage. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POS 5. The results of the analysis are that the core-damage frequency for earthquake-initiated accidents during refueling outages in POS 5 is found to be quite low in absolute terms, less than 10{sup {minus}7}/year.« less

  10. Electric system restructuring and system reliability

    NASA Astrophysics Data System (ADS)

    Horiuchi, Catherine Miller

    In 1996 the California legislature passed AB 1890, explicitly defining economic benefits and detailing specific mechanisms for initiating a partial restructuring the state's electric system. Critics have since sought re-regulation and proponents have asked for patience as the new institutions and markets take shape. Other states' electric system restructuring activities have been tempered by real and perceived problems in the California model. This study examines the reduced regulatory controls and new constraints introduced in California's limited restructuring model using utility and regulatory agency records from the 1990's to investigate effects of new institutions and practices on system reliability for the state's five largest public and private utilities. Logit and negative binomial regressions indicate negative impact from the California model of restructuring on system reliability as measured by customer interruptions. Time series analysis of outage data could not predict the wholesale power market collapse and the subsequent rolling blackouts in early 2001; inclusion of near-outage reliability disturbances---load shedding and energy emergencies---provided a measure of forewarning. Analysis of system disruptions, generation capacity and demand, and the role of purchased power challenge conventional wisdom on the causality of Californian's power problems. The quantitative analysis was supplemented by a targeted survey of electric system restructuring participants. Findings suggest each utility and the organization controlling the state's electric grid provided protection from power outages comparable to pre-restructuring operations through 2000; however, this reliability has come at an inflated cost, resulting in reduced system purchases and decreased marginal protection. The historic margin of operating safety has fully eroded, increasing mandatory load shedding and emergency declarations for voluntary and mandatory conservation. Proposed remedies focused on state-funded contracts and government-managed power authorities may not help, as the findings suggest pricing models, market uncertainty, interjurisdictional conflict and an inability to respond to market perturbations are more significant contributors to reduced regional generation availability than the particular contract mechanisms and funding sources used for power purchases.

  11. Secure Multiuser Communications in Wireless Sensor Networks with TAS and Cooperative Jamming

    PubMed Central

    Yang, Maoqiang; Zhang, Bangning; Huang, Yuzhen; Yang, Nan; Guo, Daoxing; Gao, Bin

    2016-01-01

    In this paper, we investigate the secure transmission in wireless sensor networks (WSNs) consisting of one multiple-antenna base station (BS), multiple single-antenna legitimate users, one single-antenna eavesdropper and one multiple-antenna cooperative jammer. In an effort to reduce the scheduling complexity and extend the battery lifetime of the sensor nodes, the switch-and-stay combining (SSC) scheduling scheme is exploited over the sensor nodes. Meanwhile, transmit antenna selection (TAS) is employed at the BS and cooperative jamming (CJ) is adopted at the jammer node, aiming at achieving a satisfactory secrecy performance. Moreover, depending on whether the jammer node has the global channel state information (CSI) of both the legitimate channel and the eavesdropper’s channel, it explores a zero-forcing beamforming (ZFB) scheme or a null-space artificial noise (NAN) scheme to confound the eavesdropper while avoiding the interference to the legitimate user. Building on this, we propose two novel hybrid secure transmission schemes, termed TAS-SSC-ZFB and TAS-SSC-NAN, for WSNs. We then derive the exact closed-form expressions for the secrecy outage probability and the effective secrecy throughput of both schemes to characterize the secrecy performance. Using these closed-form expressions, we further determine the optimal switching threshold and obtain the optimal power allocation factor between the BS and jammer node for both schemes to minimize the secrecy outage probability, while the optimal secrecy rate is decided to maximize the effective secrecy throughput for both schemes. Numerical results are provided to verify the theoretical analysis and illustrate the impact of key system parameters on the secrecy performance. PMID:27845753

  12. Research for the Cable Layout Way of the Bypass Operation System in Agricultural Power Supply Network

    NASA Astrophysics Data System (ADS)

    Niu, Jie; Li, Jinliang; Zou, Dehua; Yang, Qi; Li, Xu; Yan, Yu; Li, Tang

    2017-05-01

    Non-blackout working of agricultural power supply network is significant to shorten the outage time, decrease the outage loss, and improve the supply reliability and safety. It is impossible to hang the wire rope first and then suspend the cable because of the poor bearing ability of the pole in agricultural power supply network. A kind of new cable arrangement way, its matching tools and the flexible cable that can bear the tension by itself are needed to be put forward and developed. It is necessary to calculate the electric field intensity of the flexible cable to verify that the electric field intensity meets the insulation demand. In this new design, the fiber layer is added into the flexible cable and its maximum tension force is measured to reach to 4000 N. Based on the features of live working in the agricultural power supply network, the new layout way of the cable is proposed; the matching tools and the new flexible cable that can bear the tension by itself are developed as well in this paper. All of the research achievements can give references for the live working of the agricultural power supply network.

  13. Gulf Coast Hurricanes Situation Report #39

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2005-11-09

    There are 49,300 customers without power in Florida as of 7:00 AM EST 11/9 due to Hurricane Wilma, down from a peak of about 3.6 million customers. Currently, less than 1 percent of the customers are without power in the state. This is the last report we will due on outages due to Hurricane Wilma.

  14. An Adaptive Cooperative Strategy for Underlay MIMO Cognitive Radio Networks: An Opportunistic and Low-Complexity Approach

    NASA Astrophysics Data System (ADS)

    Mazoochi, M.; Pourmina, M. A.; Bakhshi, H.

    2015-03-01

    The core aim of this work is the maximization of the achievable data rate of the secondary user pairs (SU pairs), while ensuring the QoS of primary users (PUs). All users are assumed to be equipped with multiple antennas. It is assumed that when PUs are present, the direct communications between SU pairs introduces intolerable interference to PUs and thereby SUs transmit signal using the cooperation of other SUs and avoid transmitting in the direct channel. In brief, an adaptive cooperative strategy for multiple-input/multiple-output (MIMO) cognitive radio networks is proposed. At the presence of PUs, the issue of joint relay selection and power allocation in Underlay MIMO Cooperative Cognitive Radio Networks (U-MIMO-CCRN) is addressed. The optimal approach for determining the power allocation and the cooperating SU is proposed. Besides, the outage probability of the proposed communication protocol is further derived. Due to high complexity of the optimal approach, a low-complexity approach is further proposed and its performance is evaluated using simulations. The simulation results reveal that the performance loss due to the low-complexity approach is only about 14%, while the complexity is greatly reduced.

  15. NREL Validates Go Electric's Technology As Part of Wells Fargo IN2

    Science.gov Websites

    solution: providing blip-less uninterruptible power; maintaining photovoltaics systems from tripping after renewables into an energy resiliency solution and keep them operating during a grid outage." Go Electric

  16. 75 FR 8044 - Summer Undergraduate Research Program Extension of Due Date for Proposals

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ...: Due to extreme weather conditions in the Mid-Atlantic United States, NIST is extending the deadline.... Eastern Time, Tuesday, February 16, 2010. Due to extreme weather conditions and associated power outages...

  17. Interference Information Based Power Control for Cognitive Radio with Multi-Hop Cooperative Sensing

    NASA Astrophysics Data System (ADS)

    Yu, Youngjin; Murata, Hidekazu; Yamamoto, Koji; Yoshida, Susumu

    Reliable detection of other radio systems is crucial for systems that share the same frequency band. In wireless communication channels, there is uncertainty in the received signal level due to multipath fading and shadowing. Cooperative sensing techniques in which radio stations share their sensing information can improve the detection probability of other systems. In this paper, a new cooperative sensing scheme that reduces the false detection probability while maintaining the outage probability of other systems is investigated. In the proposed system, sensing information is collected using multi-hop transmission from all sensing stations that detect other systems, and transmission decisions are based on the received sensing information. The proposed system also controls the transmit power based on the received CINRs from the sensing stations. Simulation results reveal that the proposed system can reduce the outage probability of other systems, or improve its link success probability.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Severe wind and snow storms hit the Pacific Northwest region on December 14 – 15, 2006, following severe flooding during the past few days. The severe weather resulted in major power outages through the region. At peak there were 1.8 million customers without power which included BC Hydro in Canada. Currently, there are over 1.5 million outages in the region as a result of the Pacific Northwest Storms. This represents about 42 percent of customers in affected utility service areas in Oregon and Washington. See table below. Because the current wind and snow storms are coming on the heels ofmore » extensive flooding in the region, electric utilities are experiencing damage. Wind gusts reached close to 100 mph in some areas of the region. The storm is expected to bring its strong winds and heavy snow into Idaho, Montana and Wyoming Friday and into the weekend. There are currently no reported major impacts to the petroleum and natural gas infrastructure.« less

  19. Electric Power Consumption Coefficients for U.S. Industries: Regional Estimation and Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boero, Riccardo

    Economic activity relies on electric power provided by electrical generation, transmission, and distribution systems. This paper presents a method developed at Los Alamos National Laboratory to estimate electric power consumption by different industries in the United States. Results are validated through comparisons with existing literature and benchmarking data sources. We also discuss the limitations and applications of the presented method, such as estimating indirect electric power consumption and assessing the economic impact of power outages based on input-output economic models.

  20. Component Repair Times Obtained from MSPI Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eide, Steven A.; Cadwallader, Lee

    Information concerning times to repair or restore equipment to service given a failure is valuable to probabilistic risk assessments (PRAs). Examples of such uses in modern PRAs include estimation of the probability of failing to restore a failed component within a specified time period (typically tied to recovering a mitigating system before core damage occurs at nuclear power plants) and the determination of mission times for support system initiating event (SSIE) fault tree models. Information on equipment repair or restoration times applicable to PRA modeling is limited and dated for U.S. commercial nuclear power plants. However, the Mitigating Systems Performancemore » Index (MSPI) program covering all U.S. commercial nuclear power plants provides up-to-date information on restoration times for a limited set of component types. This paper describes the MSPI program data available and analyzes the data to obtain median and mean component restoration times as well as non-restoration cumulative probability curves. The MSPI program provides guidance for monitoring both planned and unplanned outages of trains of selected mitigating systems deemed important to safety. For systems included within the MSPI program, plants monitor both train UA and component unreliability (UR) against baseline values. If the combined system UA and UR increases sufficiently above established baseline results (converted to an estimated change in core damage frequency or CDF), a “white” (or worse) indicator is generated for that system. That in turn results in increased oversight by the US Nuclear Regulatory Commission (NRC) and can impact a plant’s insurance rating. Therefore, there is pressure to return MSPI program components to service as soon as possible after a failure occurs. Three sets of unplanned outages might be used to determine the component repair durations desired in this article: all unplanned outages for the train type that includes the component of interest, only unplanned outages associated with failures of the component of interest, and only unplanned outages associated with PRA failures of the component of interest. The paper will describe how component repair times can be generated from each set and which approach is most applicable. Repair time information will be summarized for MSPI pumps and diesel generators using data over 2003 – 2007. Also, trend information over 2003 – 2012 will be presented to indicate whether the 2003 – 2007 repair time information is still considered applicable. For certain types of pumps, mean repair times are significantly higher than the typically assumed 24 h duration.« less

  1. Application of flywheel battery in mobile power station

    NASA Astrophysics Data System (ADS)

    Wang, Xinggui; Zhang, Bing; Li, Xiaoying; Sun, Xiaojing

    2013-03-01

    The flywheel battery is used to the mobile station for continuous power supply, once the commercial power or other independent power supply is outage or failure, the flywheel battery will provide uninterrupted power supply during the switch to the commercial power and the diesel generator sets, ensuring the power supply system is continuous and maintaining the performance and parameters of the power supply which will not influence or discontinuous change because of commercial power failure. Simulation results show that the flywheel battery used to the mobile station can effectively improve the performance of the mobile power station system.

  2. Simplified Approach Charts Improve Data Retrieval Performance

    PubMed Central

    Stewart, Michael; Laraway, Sean; Jordan, Kevin; Feary, Michael S.

    2016-01-01

    The effectiveness of different instrument approach charts to deliver minimum visibility and altitude information during airport equipment outages was investigated. Eighteen pilots flew simulated instrument approaches in three conditions: (a) normal operations using a standard approach chart (standard-normal), (b) equipment outage conditions using a standard approach chart (standard-outage), and (c) equipment outage conditions using a prototype decluttered approach chart (prototype-outage). Errors and retrieval times in identifying minimum altitudes and visibilities were measured. The standard-outage condition produced significantly more errors and longer retrieval times versus the standard-normal condition. The prototype-outage condition had significantly fewer errors and shorter retrieval times than did the standard-outage condition. The prototype-outage condition produced significantly fewer errors but similar retrieval times when compared with the standard-normal condition. Thus, changing the presentation of minima may reduce risk and increase safety in instrument approaches, specifically with airport equipment outages. PMID:28491009

  3. 75 FR 8153 - Nebraska Public Power District; Cooper Nuclear Station Environmental Assessment and Finding of No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ... of the fall 2009 refueling outage and other factors, including inclement weather. Environmental... Management System (ADAMS) Public Electronic Reading Room on the Internet at the NRC Web site, http://www.nrc...

  4. ASDC Tools Temporarily Unavailable

    Atmospheric Science Data Center

    2015-12-21

    ... The ASDC will be conducting maintenance due to an unexpected power outage. The Data Pool, MISR order and browse tools, TAD, TES and ... may be unavailable during maintenance. Data processing and distribution may be impacted and systems are expected to return to normal ...

  5. Transmission media appropriate laser-microwave solar power satellite system

    NASA Astrophysics Data System (ADS)

    Schäfer, C. A.; Gray, D.

    2012-10-01

    As a solution to the most critical problems with Solar power Satellite (SPS) development, a system is proposed which uses laser power transmission in space to a receiver high in the atmosphere that relays the power to Earth by either cable or microwave power transmission. It has been shown in the past that such hybrid systems have the advantages of a reduction in the mass of equipment required in geostationary orbit and avoidance of radio frequency interference with other satellites and terrestrial communications systems. The advantage over a purely laser power beam SPS is that atmospheric absorption is avoided and outages due to clouds and precipitation will not occur, allowing for deployment in the equatorial zone and guaranteeing year round operation. This proposal is supported by brief literature surveys and theoretical calculations to estimate crucial parameters in this paper. In relation to this concept, we build on a recently proposed method to collect solar energy by a tethered balloon at high altitude because it enables a low-cost start for bringing the first Watt of power to Earth giving some quick return on investment, which is desperately missing in the traditional SPS concept. To tackle the significant problem of GW-class SPSs of high launch cost per kg mass brought to space, this paper introduces a concept which aims to achieve a superior power over mass ratio compared to traditional satellite designs by the use of thin-film solar cells combined with optical fibres for power delivery. To minimise the aperture sizes and cost of the transmitting and receiving components of the satellite and high altitude receiver, closed-loop laser beam pointing and target tracking is crucial for pointing a laser beam onto a target area that is of similar size to the beam's diameter. A recently developed technique based on optical phase conjugation is introduced and its applicability for maintaining power transmission between the satellite and high altitude receiver is assessed. It was found that the design of the high altitude receiver and the means of transporting the received power through the lower 21 km of the atmosphere are inextricably linked. It was concluded that an initial small scale low-cost demonstration flight of the receiver that delivers power using existing technology could be undertaken in the near future.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, S. R.; Daniel, A.

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icingmore » properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, Scott Robert

    The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkablemore » anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.« less

  8. 76 FR 31381 - Office Of New Reactors; Proposed Revision 4 to Standard Review Plan; Section 8.1 on Electric...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ...). The current revision issues a new Branch Technical Position (BTP) 8-8 on ``Onsite (Emergency Diesel Generators) and Offsite Power Sources Allowed Outage Time Extensions.'' (ADAMS Accession No. ML111180521...

  9. Valuing the Resilience Provided by Solar and Battery Energy Storage Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaren, Joyce A; Mullendore, Seth; Laws, Nicholas D

    This paper explores the impact of valuing resilience on the economics of photovoltaics (PV) and storage systems for commercial buildings. The analysis presented here illustrates that accounting for the cost of grid power outages can change the breakeven point for PV and storage system investment, and increase the size of systems designed to deliver the greatest economic benefit over time. In other words, valuing resilience can make PV and storage systems economical in cases where they would not be otherwise. As storage costs decrease, and outages occur more frequently, PV and storage are likely to play a larger role inmore » building design and management considerations.« less

  10. Optimal Performance Monitoring of Hybrid Mid-Infrared Wavelength MIMO Free Space Optical and RF Wireless Networks in Fading Channels

    NASA Astrophysics Data System (ADS)

    Schmidt, Barnet Michael

    An optimal performance monitoring metric for a hybrid free space optical and radio-frequency (RF) wireless network, the Outage Capacity Objective Function, is analytically developed and studied. Current and traditional methods of performance monitoring of both optical and RF wireless networks are centered on measurement of physical layer parameters, the most common being signal-to-noise ratio, error rate, Q factor, and eye diagrams, occasionally combined with link-layer measurements such as data throughput, retransmission rate, and/or lost packet rate. Network management systems frequently attempt to predict or forestall network failures by observing degradations of these parameters and to attempt mitigation (such as offloading traffic, increasing transmitter power, reducing the data rate, or combinations thereof) prior to the failure. These methods are limited by the frequent low sensitivity of the physical layer parameters to the atmospheric optical conditions (measured by optical signal-to-noise ratio) and the radio frequency fading channel conditions (measured by signal-to-interference ratio). As a result of low sensitivity, measurements of this type frequently are unable to predict impending failures sufficiently in advance for the network management system to take corrective action prior to the failure. We derive and apply an optimal measure of hybrid network performance based on the outage capacity of the hybrid optical and RF channel, the outage capacity objective function. The objective function provides high sensitivity and reliable failure prediction, and considers both the effects of atmospheric optical impairments on the performance of the free space optical segment as well as the effect of RF channel impairments on the radio frequency segment. The radio frequency segment analysis considers the three most common RF channel fading statistics: Rayleigh, Ricean, and Nakagami-m. The novel application of information theory to the underlying physics of the gamma-gamma optical channel and radio fading channels in determining the joint hybrid channel outage capacity provides the best performance estimate under any given set of operating conditions. It is shown that, unlike traditional physical layer performance monitoring techniques, the objective function based upon the outage capacity of the hybrid channel at any combination of OSNR and SIR, is able to predict channel degradation and failure well in advance of the actual outage. An outage in the information-theoretic definition occurs when the offered load exceeds the outage capacity under the current conditions of OSNR and SIR. The optical channel is operated at the "long" mid-infrared wavelength of 10000 nm. which provides improved resistance to scattering compared to shorter wavelengths such as 1550 nm.

  11. Dynamic analysis method for prevention of failure in the first-stage low-pressure turbine blade with two-finger root

    NASA Astrophysics Data System (ADS)

    Park, Jung-Yong; Jung, Yong-Keun; Park, Jong-Jin; Kang, Yong-Ho

    2002-05-01

    Failures of turbine blades are identified as the leading causes of unplanned outages for steam turbine. Accidents of low-pressure turbine blade occupied more than 70 percent in turbine components. Therefore, the prevention of failures for low pressure turbine blades is certainly needed. The procedure is illustrated by the case study. This procedure is used to guide, and support the plant manager's decisions to avoid a costly, unplanned outage. In this study, we are trying to find factors of failures in LP turbine blade and to make three steps to approach the solution of blade failure. First step is to measure natural frequency in mockup test and to compare it with nozzle passing frequency. Second step is to use FEM and to calculate the natural frequencies of 7 blades and 10 blades per group in BLADE code. Third step is to find natural frequencies of grouped blade off the nozzle passing frequency.

  12. Keep Food and Water Safe After a Disaster or Power Outage

    MedlinePlus

    ... DO NOT drink the water. Use a safe water supply like bottled or treated water. Contact your local, ... you know the water is safe, use bottled water or some other safe supply of water. If you suspect your water has ...

  13. Demonstration of a Novel Synchrophasor-based Situational Awareness System: Wide Area Power System Visualization, On-line Event Replay and Early Warning of Grid Problems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosso, A.

    Since the large North Eastern power system blackout on August 14, 2003, U.S. electric utilities have spent lot of effort on preventing power system cascading outages. Two of the main causes of the August 14, 2003 blackout were inadequate situational awareness and inadequate operator training In addition to the enhancements of the infrastructure of the interconnected power systems, more research and development of advanced power system applications are required for improving the wide-area security monitoring, operation and planning in order to prevent large- scale cascading outages of interconnected power systems. It is critically important for improving the wide-area situation awarenessmore » of the operators or operational engineers and regional reliability coordinators of large interconnected systems. With the installation of large number of phasor measurement units (PMU) and the related communication infrastructure, it will be possible to improve the operators’ situation awareness and to quickly identify the sequence of events during a large system disturbance for the post-event analysis using the real-time or historical synchrophasor data. The purpose of this project was to develop and demonstrate a novel synchrophasor-based comprehensive situational awareness system for control centers of power transmission systems. The developed system named WASA (Wide Area Situation Awareness) is intended to improve situational awareness at control centers of the power system operators and regional reliability coordinators. It consists of following main software modules: • Wide-area visualizations of real-time frequency, voltage, and phase angle measurements and their contour displays for security monitoring. • Online detection and location of a major event (location, time, size, and type, such as generator or line outage). • Near-real-time event replay (in seconds) after a major event occurs. • Early warning of potential wide-area stability problems. The system has been deployed and demonstrated at the Tennessee Valley Authority (TVA) and ISO New England system using real-time synchrophasor data from openPDC. Apart from the software product, the outcome of this project consists of a set of technical reports and papers describing the mathematical foundations and computational approaches of different tools and modules, implementation issues and considerations, lessons learned, and the results of lidation processes.« less

  14. Multiline radar scan

    NASA Technical Reports Server (NTRS)

    Levinson, S.

    1977-01-01

    Scanning scheme is more efficient than conventional scanning. Originally designed for optical radar in space vehicles, scheme may also find uses in site-surveillance security systems and in other industrial applications. It should be particularly useful when system must run on battery energy, as would be case in power outages.

  15. Global Positioning System Disaster Notification Messaging Service

    DTIC Science & Technology

    2013-09-01

    under AT&T service. Differing combinations of phone operating system types and versions (Android, iOS, Windows 8, Blackberry OS, et al.) service...streets, tunnels and subways. Substantial damage was incurred along the Atlantic coasts of both states with sustained power outages. As the storm’s

  16. 77 FR 3752 - Commission Information Collection Activities (FERC-725I); Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-25

    ... the Bulk-Power System to system disturbances, including scheduled and unscheduled outages; requires each reliability coordinator to establish requirements for its area's dynamic disturbance recording... Retention--10.... 10 acquisition and installation of dynamic disturbance recorders. GO, TO, and RC to...

  17. 75 FR 80391 - Electric Reliability Organization Interpretations of Interconnection Reliability Operations and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-22

    ... configuration to maintain system stability, acceptable voltage or power flows.\\12\\ \\12\\ In the Western... prevent system instability or cascading outages, and protect other facilities in response to transmission... nature used to address system reliability vulnerabilities to prevent system instability, cascading...

  18. Opportunistic Beamforming with Wireless Powered 1-bit Feedback Through Rectenna Array

    NASA Astrophysics Data System (ADS)

    Krikidis, Ioannis

    2015-11-01

    This letter deals with the opportunistic beamforming (OBF) scheme for multi-antenna downlink with spatial randomness. In contrast to conventional OBF, the terminals return only 1-bit feedback, which is powered by wireless power transfer through a rectenna array. We study two fundamental topologies for the combination of the rectenna elements; the direct-current combiner and the radio-frequency combiner. The beam outage probability is derived in closed form for both combination schemes, by using high order statistics and stochastic geometry.

  19. A software framework for assessing the resilience of drinking ...

    EPA Pesticide Factsheets

    Journal article This paper introduces a new software tool called the Water Network Tool for Resilience (WNTR) that water utilities can use to assess their resilience to disasters. A case study of an earthquake is included that results in damage to pipes and tanks, fires, and power outages. The utility uses several response strategies including fixing damaged pipes and tanks, restoring power, fighting fires, and implementing conservation.

  20. 75 FR 6225 - Northern States Power Company-Minnesota; Prairie Island Nuclear Generating Plant Units 1 and 2...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-08

    ... modifications of this scope, and the impediments to construction such as the planned refueling outages at both... on the Internet at the NRC Web site: http://www.nrc.gov/reading-rm/adams.html . Persons who do not...

  1. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  2. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  3. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  4. 10 CFR 205.371 - Definition of emergency.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Transfer of Electricity to Alleviate An Emergency Shortage of Electric Power § 205.371 Definition of... of the necessary fuels to generate electricity, or a regulatory action which prohibits the use of.... Where an electricity outage or service inadequacy qualifies for a section 202(c) order, contractual...

  5. A fouling monitor alarm to prevent forced outages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, R.E.; Hickinbotham, A.; Fang, T.C.

    2000-07-01

    Many utilities rely on coal blending to meet emissions and boiler performance goals, but the increased variability in coal quality can adversely impact ash deposition and soot blowing requirements. Other utilities are experimenting with lower quality coals and burner zone blending of coals fired from different bunkers as part of a deregulation strategy to reduce fuel costs. However, these strategies can lead to slagging/fouling episodes, a possible outage, or a decrease in unit availability if boiler operations are not carefully monitored. This paper summarizes the development of software to monitor boiler fouling and to provide an advanced warning to themore » control operators when a fouling episode is imminent. With adequate warming, preemptive action can be taken (e.g., soot blowing, a change in coal blend, etc.) to potentially avoid a costly outage. The software utilizes a unique combination of combustion diagnostic techniques and convective section heat adsorption analyses to identify boiler operating conditions where ash deposition rates may be high and conductive to triggering a fouling episode. The paper outlines the history of the fouling problem and the implementation of the software on Wabamun Unit 4, a tangentially-fired unit with relatively narrow reheat tube spacing. The unit had a tendency to foul when burning a high alkaline (but low ash) coal seam. The paper discusses the software development, implementation, and data acquisitions activities. Preliminary test results are provided for Wabamun 4 and for Sundance Units 1 and 2 where the software was recently installed.« less

  6. Channel Deviation-Based Power Control in Body Area Networks.

    PubMed

    Van, Son Dinh; Cotton, Simon L; Smith, David B

    2018-05-01

    Internet enabled body area networks (BANs) will form a core part of future remote health monitoring and ambient assisted living technology. In BAN applications, due to the dynamic nature of human activity, the off-body BAN channel can be prone to deep fading caused by body shadowing and multipath fading. Using this knowledge, we present some novel practical adaptive power control protocols based on the channel deviation to simultaneously prolong the lifetime of wearable devices and reduce outage probability. The proposed schemes are both flexible and relatively simple to implement on hardware platforms with constrained resources making them inherently suitable for BAN applications. We present the key algorithm parameters used to dynamically respond to the channel variation. This allows the algorithms to achieve a better energy efficiency and signal reliability in everyday usage scenarios such as those in which a person undertakes many different activities (e.g., sitting, walking, standing, etc.). We also profile their performance against traditional, optimal, and other existing schemes for which it is demonstrated that not only does the outage probability reduce significantly, but the proposed algorithms also save up to average transmit power compared to the competing schemes.

  7. ORAM-SENTINEL{trademark} demonstration at Fitzpatrick. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, L.K.; Anderson, V.M.; Mohammadi, K.

    1998-06-01

    New York Power Authority, in cooperation with EPRI, installed the ORAM-SENTINEL{trademark} software at James A. Fitzpatrick (JAF) Nuclear Power Plant. This software incorporates models of safety systems and support systems that are used for defense-in-depth in the plant during outage and on-line periods. A secondary goal was to include some pre-analyzed risk results to validate the methodology for quantitative assessment of the plant risks during proposed on-line maintenance. During the past year, New York Power Authority personnel have become familiar with the formal computerized Safety Assessment process associated with on-line and outage maintenance. The report describes techniques and lessons learnedmore » during development of the ORAM-SENTINEL model at JAF. It overviews the systems important to the Safety Function Assessment Process and provides details on development of the Plant Transient Assessment process using the station emergency operating procedures. The assessment results are displayed by color (green, yellow, orange, red) to show decreasing safety conditions. The report describes use of the JAF Probabilistic Safety Assessment within the ORAM-SENTINEL code to calculate an instantaneous core damage frequency and the criteria by which this frequency is translated to a color indicator.« less

  8. Analytical Approaches for Identification and Representation of Critical Protection Systems in Transient Stability Studies

    NASA Astrophysics Data System (ADS)

    Hedman, Mojdeh Khorsand

    After a major disturbance, the power system response is highly dependent on protection schemes and system dynamics. Improving power systems situational awareness requires proper and simultaneous modeling of both protection schemes and dynamic characteristics in power systems analysis tools. Historical information and ex-post analysis of blackouts reaffirm the critical role of protective devices in cascading events, thereby confirming the necessity to represent protective functions in transient stability studies. This dissertation is aimed at studying the importance of representing protective relays in power system dynamic studies. Although modeling all of the protective relays within transient stability studies may result in a better estimation of system behavior, representing, updating, and maintaining the protection system data becomes an insurmountable task. Inappropriate or outdated representation of the relays may result in incorrect assessment of the system behavior. This dissertation presents a systematic method to determine essential relays to be modeled in transient stability studies. The desired approach should identify protective relays that are critical for various operating conditions and contingencies. The results of the transient stability studies confirm that modeling only the identified critical protective relays is sufficient to capture system behavior for various operating conditions and precludes the need to model all of the protective relays. Moreover, this dissertation proposes a method that can be implemented to determine the appropriate location of out-of-step blocking relays. During unstable power swings, a generator or group of generators may accelerate or decelerate leading to voltage depression at the electrical center along with generator tripping. This voltage depression may cause protective relay mis-operation and unintentional separation of the system. In order to avoid unintentional islanding, the potentially mis-operating relays should be blocked from tripping with the use of out-of-step blocking schemes. Blocking these mis-operating relays, combined with an appropriate islanding scheme, help avoid a system wide collapse. The proposed method is tested on data from the Western Electricity Coordinating Council. A triple line outage of the California-Oregon Intertie is studied. The results show that the proposed method is able to successfully identify proper locations of out-of-step blocking scheme.

  9. National Marrow Donor Program

    DTIC Science & Technology

    2010-11-05

    from power or Internet outages to severe weather. • Received 50 mobile broadband air cards at minimal cost to the organization and ONR to allow for...CLlA CME CMF COG CREG CSS CT CTA DC DHHS-ASPR DIY DKMS DMSO DoD DNA DIR EBMT EM EMDIS ENS ERSI FBI QUARTER PROGRESS REPORT

  10. Putting Patience to the Test

    NASA Technical Reports Server (NTRS)

    Morgan, Ray

    2004-01-01

    A project manager recounts his decisions before and during the aftermath of the crash of a full-size flying model of Quetzalcoatlus northropi. The unstable pterodactyl crashed without harming anyone, although it caused a local power outage. The manager summarizes lessons learned about flight testing prototypes, including the effects of impatience.

  11. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  12. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  13. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  14. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  15. 32 CFR 842.31 - Claims payable.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... which last for an extended period of time. The claimant must be free of negligence. (i) Claims for..., or power outages which last for an extended period of time. The claimant must be free of negligence... jettisoned baggage, clothing worn at the time of an incident, and reasonable amounts of money, jewelry, and...

  16. 78 FR 18974 - Increasing Market and Planning Efficiency Through Improved Software; Notice of Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-28

    ... bring together experts from diverse backgrounds and experiences including electric system operators... transmission switching; AC optimal power flow modeling; and use of active and dynamic transmission ratings. In... variability of the system, including forecast error? [cir] How can outage probability be captured in...

  17. 40 CFR 270.14 - Contents of part B: General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... strata, surface water, or air, which may include the installation of wells, where the Director ascertains... water supplies; (iv) Mitigate effects of equipment failure and power outages; (v) Prevent undue exposure... contour interval must be sufficient to clearly show the pattern of surface water flow in the vicinity of...

  18. Naturalistic Decision Making For Power System Operators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greitzer, Frank L.; Podmore, Robin; Robinson, Marck

    2009-06-23

    Abstract: Motivation -- As indicated by the Blackout of 2003, the North American interconnected electric system is vulnerable to cascading outages and widespread blackouts. Investigations of large scale outages often attribute the causes to the three T’s: Trees, Training and Tools. A systematic approach has been developed to document and understand the mental processes that an expert power system operator uses when making critical decisions. The approach has been developed and refined as part of a capability demonstration of a high-fidelity real-time power system simulator under normal and emergency conditions. To examine naturalistic decision making (NDM) processes, transcripts of operator-to-operatormore » conversations are analyzed to reveal and assess NDM-based performance criteria. Findings/Design -- The results of the study indicate that we can map the Situation Awareness Level of the operators at each point in the scenario. We can also identify clearly what mental models and mental simulations are being performed at different points in the scenario. As a result of this research we expect that we can identify improved training methods and improved analytical and visualization tools for power system operators. Originality/Value -- The research applies for the first time, the concepts of Recognition Primed Decision Making, Situation Awareness Levels and Cognitive Task Analysis to training of electric power system operators. Take away message -- The NDM approach provides an ideal framework for systematic training management and mitigation to accelerate learning in team-based training scenarios with high-fidelity power grid simulators.« less

  19. A simple model for DSS-14 outage times

    NASA Technical Reports Server (NTRS)

    Rumsey, H. C.; Stevens, R.; Posner, E. C.

    1989-01-01

    A model is proposed to describe DSS-14 outage times. Discrepancy Reporting System outage data for the period from January 1986 through September 1988 are used to estimate the parameters of the model. The model provides a probability distribution for the duration of outages, which agrees well with observed data. The model depends only on a small number of parameters, and has some heuristic justification. This shows that the Discrepancy Reporting System in the Deep Space Network (DSN) can be used to estimate the probability of extended outages in spite of the discrepancy reports ending when the pass ends. The probability of an outage extending beyond the end of a pass is estimated as around 5 percent.

  20. Outage maintenance checks on large generator windings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nindra, B.; Jeney, S.I.; Slobodinsky, Y.

    In the present days of austerity, more constraints and pressures are being brought on the maintenance engineers to certify the generators for their reliability and life extension. The outages are shorter and intervals between the outages are becoming longer. The annual outages were very common when utilities had no regulatory constraints and also had standby capacities. Furthermore, due to lean and mean budgets, outage maintenance programs are being pursued more aggressively, so that longer interval outages can be achieved to ensure peak generator performance. This paper will discuss various visual checks, electrical tests and recommended fixes to achieve the abovemore » mentioned objectives, in case any deficiencies are found.« less

  1. Simulation of switching overvoltages in the mine electric power supply system

    NASA Astrophysics Data System (ADS)

    Ivanchenko, D. I.; Novozhilov, N. G.

    2017-02-01

    Overvoltages occur in mine power supply systems during switching off consumers with high inductive load, such as transformers, reactors and electrical machines. Overvoltages lead to an increase of insulation degradation rate and may cause electric faults, power outage, fire and explosion of methane and coal dust. This paper is dedicated to simulation of vacuum circuit breaker switching overvoltages in a mine power supply system by means of Simulink MATLAB. The model of the vacuum circuit breaker implements simulation of transient recovery voltage, current chopping and an electric arc. Obtained results were compared to available experimental data.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Richard P.; Stamp, Jason E.; Eddy, John P.

    Many critical loads rely on simple backup generation to provide electricity in the event of a power outage. An Energy Surety Microgrid TM can protect against outages caused by single generator failures to improve reliability. An ESM will also provide a host of other benefits, including integration of renewable energy, fuel optimization, and maximizing the value of energy storage. The ESM concept includes a categorization for microgrid value proposi- tions, and quantifies how the investment can be justified during either grid-connected or utility outage conditions. In contrast with many approaches, the ESM approach explic- itly sets requirements based on unlikelymore » extreme conditions, including the need to protect against determined cyber adversaries. During the United States (US) Department of Defense (DOD)/Department of Energy (DOE) Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) effort, the ESM methodology was successfully used to develop the preliminary designs, which direct supported the contracting, construction, and testing for three military bases. Acknowledgements Sandia National Laboratories and the SPIDERS technical team would like to acknowledge the following for help in the project: * Mike Hightower, who has been the key driving force for Energy Surety Microgrids * Juan Torres and Abbas Akhil, who developed the concept of microgrids for military installations * Merrill Smith, U.S. Department of Energy SPIDERS Program Manager * Ross Roley and Rich Trundy from U.S. Pacific Command * Bill Waugaman and Bill Beary from U.S. Northern Command * Melanie Johnson and Harold Sanborn of the U.S. Army Corps of Engineers Construc- tion Engineering Research Laboratory * Experts from the National Renewable Energy Laboratory, Idaho National Laboratory, Oak Ridge National Laboratory, and Pacific Northwest National Laboratory« less

  3. Defending the Power Grid from Hackers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eber, Kevin

    A new initiative underway at the National Renewable Energy Laboratory is intended to prevent hackers from gaining control of parts of the nation's power grid, potentially damaging electrical equipment and causing localized power outages. Our nation's power grid is evolving to be more responsive to changing power needs, more able to integrate renewable energy, more efficient, and more reliable. One key element of this evolution is adding communication and control devices to the power grid, closer to the end user, so that utilities have greater situational awareness of the grid and can respond quickly to disturbances. But these new devicesmore » and their communications requirements can also open up the power grid to potential cyber attacks.« less

  4. The Traffic Light Challenge

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2014-01-01

    Traffic lights are an important part of the transportation infrastructure, regulating traffic flow and maintaining safety when crossing busy streets. When they go awry or become nonfunctional, a great deal of havoc and danger can be present. During power outages, the street lights go out all over the affected area. It would be good to be able to…

  5. Disaster Recovery: Courting Disaster

    ERIC Educational Resources Information Center

    O'Hanlon, Charlene

    2007-01-01

    An inadequate or nonexistent disaster recovery plan can have dire results. Fire, power outage, and severe weather all can brin down the best of networks in an instant. This article draws on the experiences of the Charlotte County Public Schools (Port Charlotte, Florida), which were able to lessen the damage caused by Hurricane Charley when it hit…

  6. 40 CFR 270.290 - What general types of information must I keep at my facility?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and power outages, (5) Prevent undue exposure of personnel to hazardous waste (for example, requiring.... (n) [Reserved] (o) The most recent closure cost estimate for your facility prepared under 40 CFR 267... land uses (residential, commercial, agricultural, recreational). (5) A wind rose (i.e., prevailing wind...

  7. 40 CFR 270.290 - What general types of information must I keep at my facility?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and power outages, (5) Prevent undue exposure of personnel to hazardous waste (for example, requiring.... (n) [Reserved] (o) The most recent closure cost estimate for your facility prepared under 40 CFR 267... land uses (residential, commercial, agricultural, recreational). (5) A wind rose (i.e., prevailing wind...

  8. Disaster Response and Planning for Libraries, Third Edition

    ERIC Educational Resources Information Center

    Kahn, Miriam B.

    2012-01-01

    Fire, water, mold, construction problems, power-outages--mishaps like these can not only bring library services to a grinding halt, but can also destroy collections and even endanger employees. Preparing for the unexpected is the foundation of a library's best response. Expert Kahn comes to the rescue with this timely update of the best…

  9. Optimization of replacement and inspection decisions for multiple components on a power system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mauney, D.A.

    1994-12-31

    The use of optimization on the rescheduling of replacement dates provided a very proactive approach to deciding when components on individual units need to be addressed with a run/repair/replace decision. Including the effects of time value of money and taxes and unit need inside the spreadsheet model allowed the decision maker to concentrate on the effects of engineering input and replacement date decisions on the final net present value (NPV). The personal computer (PC)-based model was applied to a group of 140 forced outage critical fossil plant tube components across a power system. The estimated resulting NPV of the optimizationmore » was in the tens of millions of dollars. This PC spreadsheet model allows the interaction of inputs from structural reliability risk assessment models, plant foreman interviews, and actual failure history on a by component by unit basis across a complete power production system. This model includes not only the forced outage performance of these components caused by tube failures but, in addition, the forecasted need of the individual units on the power system and the expected cost of their replacement power if forced off line. The use of cash flow analysis techniques in the spreadsheet model results in the calculation of an NPV for a whole combination of replacement dates. This allows rapid assessments of {open_quotes}what if{close_quotes} scenarios of major maintenance projects on a systemwide basis and not just on a unit-by-unit basis.« less

  10. SPALLMAP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sabau, Adrian; Wright, Ian

    Boiler tubes in steam power plants experience exfoliation of oxide grown on the inner side of the tubes. In extreme cases, the exfoliation cause significant tube blockages that lead to forced power plant outages. It is thus desired to predict through modeling the propensity of exfoliation events in order to inform power plant operators of possible tube blockages. SpallMap solves for the stress-strain equations in an axisymmetric geometry, tracking the stress/strain evolution during boiler operation including outages at one-location along a boiler tube and compares it with scale damage criteria represented by Armitt diagram. The SPALLMAP code contains modules developedmore » for oxide growth, stress analysis, and classical fracture mechanics correlations by taking into account the following phenomena and features, (a) Non-uniform thermal expansion coefficient of oxides and metal substrates, (b) Plant operation schedule with periodic alternate full-load and partial-load regimes, (c) axisymmetric formulation for cylindrical tubes, (d) Multiple oxide layers, (e) oxide-growth induced stresses, and (f) damage criteria from classical fracture mechanics. The computer program is written in FORTRAN90. Its modular structure was sought for allowing the best flexibility in updating the program by implementing new constitutive equations due to availability of new material property data and/or new physical phenomena.« less

  11. A survey of customers of space weather information

    NASA Astrophysics Data System (ADS)

    Schrijver, C. J.; Rabanal, J. P.

    2013-09-01

    We present an analysis of the users of space weather information based on 2783 responses to an online survey among subscribers of NOAA's Space Weather Prediction Center e-mail services. The survey requested information focused on the three NOAA space weather scales: geomagnetic storms, solar radiation storms, and radio blackouts. Space weather information is most commonly obtained for reasons of human safety and continuity or reliability of operations. The information is primarily used for situational awareness, as aid to understand anomalies, to avoid impacts on current and near-future operations by implementing mitigating strategies, and to prepare for potential near-future impacts that might occur in conjunction with contingencies that include electric power outages or GPS perturbations. Interest in, anticipated impacts from, and responses to the three main categories of space weather are quite uniform across societal sectors. Approximately 40% of the respondents expect serious to very serious impacts from space weather events if no action were taken to mitigate or in the absence of adequate space weather information. The impacts of space weather are deemed to be substantially reduced because of the availability of, and their response to, space weather forecasts and alerts. Current and near-future space weather conditions are generally highly valued, considered useful, and generally, though not fully, adequate to avoid or mitigate societal impacts. We conclude that even among those receiving space weather information, there is considerable uncertainty about the possible impacts of space weather and thus about how to act on the space weather information that is provided.

  12. 77 FR 74788 - Long-Term Cooling and Unattended Water Makeup of Spent Fuel Pools

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-18

    ... frequency estimate of 1 in 100 years (1E-2/yr) for extreme space weather/ geomagnetic disturbance to perform... Accidents B. Geomagnetic Storms and Effects on the Earth C. Frequency of Geomagnetic Storms With Potential... commercial electric power grids are vulnerable to prolonged outage caused by extreme space weather, such as...

  13. 77 FR 68196 - Orders Limiting Operations at John F. Kennedy International Airport, LaGuardia Airport, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-15

    ... to an extratropical storm that caused widespread power outages, severe flooding, and severe... storm. FAA Analysis Under the FAA's High Density Rule at DCA and Orders limiting operations at LGA, JFK... area or northeastern U.S. affected by the storm. These circumstances may have created a unique hardship...

  14. Academic Continuity: Staying True to Teaching Values and Objectives in the Face of Course Interruptions

    ERIC Educational Resources Information Center

    Day, Terence

    2015-01-01

    Academic continuity planning is an emerging tool for dealing with class cancellation associated with natural disasters, acts of violence and the threat of pandemics. However, academic continuity can also be an issue with respect to less dramatic events, such as power outages, inclement weather, or the temporary unavailability of an instructor,…

  15. Water Network Tool for Resilience v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-12-09

    WNTR is a python package designed to simulate and analyze resilience of water distribution networks. The software includes: - Pressure driven and demand driven hydraulic simulation - Water quality simulation to track concentration, trace, and water age - Conditional controls to simulate power outages - Models to simulate pipe breaks - A wide range of resilience metrics - Analysis and visualization tools

  16. Outage probability of a relay strategy allowing intra-link errors utilizing Slepian-Wolf theorem

    NASA Astrophysics Data System (ADS)

    Cheng, Meng; Anwar, Khoirul; Matsumoto, Tad

    2013-12-01

    In conventional decode-and-forward (DF) one-way relay systems, a data block received at the relay node is discarded, if the information part is found to have errors after decoding. Such errors are referred to as intra-link errors in this article. However, in a setup where the relay forwards data blocks despite possible intra-link errors, the two data blocks, one from the source node and the other from the relay node, are highly correlated because they were transmitted from the same source. In this article, we focus on the outage probability analysis of such a relay transmission system, where source-destination and relay-destination links, Link 1 and Link 2, respectively, are assumed to suffer from the correlated fading variation due to block Rayleigh fading. The intra-link is assumed to be represented by a simple bit-flipping model, where some of the information bits recovered at the relay node are the flipped version of their corresponding original information bits at the source. The correlated bit streams are encoded separately by the source and relay nodes, and transmitted block-by-block to a common destination using different time slots, where the information sequence transmitted over Link 2 may be a noise-corrupted interleaved version of the original sequence. The joint decoding takes place at the destination by exploiting the correlation knowledge of the intra-link (source-relay link). It is shown that the outage probability of the proposed transmission technique can be expressed by a set of double integrals over the admissible rate range, given by the Slepian-Wolf theorem, with respect to the probability density function ( pdf) of the instantaneous signal-to-noise power ratios (SNR) of Link 1 and Link 2. It is found that, with the Slepian-Wolf relay technique, so far as the correlation ρ of the complex fading variation is | ρ|<1, the 2nd order diversity can be achieved only if the two bit streams are fully correlated. This indicates that the diversity order exhibited in the outage curve converges to 1 when the bit streams are not fully correlated. Moreover, the Slepian-Wolf outage probability is proved to be smaller than that of the 2nd order maximum ratio combining (MRC) diversity, if the average SNRs of the two independent links are the same. Exact as well as asymptotic expressions of the outage probability are theoretically derived in the article. In addition, the theoretical outage results are compared with the frame-error-rate (FER) curves, obtained by a series of simulations for the Slepian-Wolf relay system based on bit-interleaved coded modulation with iterative detection (BICM-ID). It is shown that the FER curves exhibit the same tendency as the theoretical results.

  17. Technology Integration Initiative In Support of Outage Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory Weatherby; David Gertman

    2012-07-01

    Plant outage management is a high priority concern for the nuclear industry from cost and safety perspectives. Often, command and control during outages is maintained in the outage control center where many of the underlying technologies supporting outage control are the same as those used in the 1980’s. This research reports on the use of advanced integrating software technologies and hand held mobile devices as a means by which to reduce cycle time, improve accuracy, and enhance transparency among outage team members. This paper reports on the first phase of research supported by the DOE Light Water Reactor Sustainability (LWRS)more » Program that is performed in close collaboration with industry to examine the introduction of newly available technology allowing for safe and efficient outage performance. It is thought that this research will result in: improved resource management among various plant stakeholder groups, reduced paper work, and enhanced overall situation awareness for the outage control center management team. A description of field data collection methods, including personnel interview data, success factors, end-user evaluation and integration of hand held devices in achieving an integrated design are also evaluated. Finally, the necessity of obtaining operations cooperation support in field studies and technology evaluation is acknowledged.« less

  18. Improving Energy Security for Air Force Installations

    NASA Astrophysics Data System (ADS)

    Schill, David

    Like civilian infrastructure, Air Force installations are dependent on electrical energy for daily operations. Energy shortages translate to decreased productivity, higher costs, and increased health risks. But for the United States military, energy shortages have the potential to become national security risks. Over ninety-five percent of the electrical energy used by the Air Force is supplied by the domestic grid, which is susceptible to shortages and disruptions. Many Air Force operations require a continuous source of energy, and while the Air Force has historically established redundant supplies of electrical energy, these back-ups are designed for short-term outages and may not provide sufficient supply for a longer, sustained power outage. Furthermore, it is the goal of the Department of Defense to produce or procure 25 percent of its facility energy from renewable sources by fiscal year 2025. In a government budget environment where decision makers are required to provide more capability with less money, it is becoming increasingly important for informed decisions regarding which energy supply options bear the most benefit for an installation. The analysis begins by exploring the field of energy supply options available to an Air Force installation. The supply options are assessed according to their ability to provide continuous and reliable energy, their applicability to unique requirements of Air Force installations, and their costs. Various methods of calculating energy usage by an installation are also addressed. The next step of this research develops a methodology and tool which assesses how an installation responds to various power outage scenarios. Lastly, various energy supply options are applied to the tool, and the results are reported in terms of cost and loss of installation capability. This approach will allow installation commanders and energy managers the ability to evaluate the cost and effectiveness of various energy investment options.

  19. Smart distribution systems

    DOE PAGES

    Jiang, Yazhou; Liu, Chen -Ching; Xu, Yin

    2016-04-19

    The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs) and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs) of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. Amore » comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD), is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Furthermore, test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs) is introduced. Future research in a smart distribution environment is proposed.« less

  20. A smart Monte Carlo procedure for production costing and uncertainty analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, C.; Stremel, J.

    1996-11-01

    Electric utilities using chronological production costing models to decide whether to buy or sell power over the next week or next few weeks need to determine potential profits or losses under a number of uncertainties. A large amount of money can be at stake--often $100,000 a day or more--and one party of the sale must always take on the risk. In the case of fixed price ($/MWh) contracts, the seller accepts the risk. In the case of cost plus contracts, the buyer must accept the risk. So, modeling uncertainty and understanding the risk accurately can improve the competitive edge ofmore » the user. This paper investigates an efficient procedure for representing risks and costs from capacity outages. Typically, production costing models use an algorithm based on some form of random number generator to select resources as available or on outage. These algorithms allow experiments to be repeated and gains and losses to be observed in a short time. The authors perform several experiments to examine the capability of three unit outage selection methods and measures their results. Specifically, a brute force Monte Carlo procedure, a Monte Carlo procedure with Latin Hypercube sampling, and a Smart Monte Carlo procedure with cost stratification and directed sampling are examined.« less

  1. A Bayesian Approach Based Outage Prediction in Electric Utility Systems Using Radar Measurement Data

    DOE PAGES

    Yue, Meng; Toto, Tami; Jensen, Michael P.; ...

    2017-05-18

    Severe weather events such as strong thunderstorms are some of the most significant and frequent threats to the electrical grid infrastructure. Outages resulting from storms can be very costly. While some tools are available to utilities to predict storm occurrences and damage, they are typically very crude and provide little means of facilitating restoration efforts. This study developed a methodology to use historical high-resolution (both temporal and spatial) radar observations of storm characteristics and outage information to develop weather condition dependent failure rate models (FRMs) for different grid components. Such models can provide an estimation or prediction of the outagemore » numbers in small areas of a utility’s service territory once the real-time measurement or forecasted data of weather conditions become available as the input to the models. Considering the potential value provided by real-time outages reported, a Bayesian outage prediction (BOP) algorithm is proposed to account for both strength and uncertainties of the reported outages and failure rate models. The potential benefit of this outage prediction scheme is illustrated in this study.« less

  2. A Bayesian Approach Based Outage Prediction in Electric Utility Systems Using Radar Measurement Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Meng; Toto, Tami; Jensen, Michael P.

    Severe weather events such as strong thunderstorms are some of the most significant and frequent threats to the electrical grid infrastructure. Outages resulting from storms can be very costly. While some tools are available to utilities to predict storm occurrences and damage, they are typically very crude and provide little means of facilitating restoration efforts. This study developed a methodology to use historical high-resolution (both temporal and spatial) radar observations of storm characteristics and outage information to develop weather condition dependent failure rate models (FRMs) for different grid components. Such models can provide an estimation or prediction of the outagemore » numbers in small areas of a utility’s service territory once the real-time measurement or forecasted data of weather conditions become available as the input to the models. Considering the potential value provided by real-time outages reported, a Bayesian outage prediction (BOP) algorithm is proposed to account for both strength and uncertainties of the reported outages and failure rate models. The potential benefit of this outage prediction scheme is illustrated in this study.« less

  3. Reciprocally-Benefited Secure Transmission for Spectrum Sensing-Based Cognitive Radio Sensor Networks

    PubMed Central

    Wang, Dawei; Ren, Pinyi; Du, Qinghe; Sun, Li; Wang, Yichen

    2016-01-01

    The rapid proliferation of independently-designed and -deployed wireless sensor networks extremely crowds the wireless spectrum and promotes the emergence of cognitive radio sensor networks (CRSN). In CRSN, the sensor node (SN) can make full use of the unutilized licensed spectrum, and the spectrum efficiency is greatly improved. However, inevitable spectrum sensing errors will adversely interfere with the primary transmission, which may result in primary transmission outage. To compensate the adverse effect of spectrum sensing errors, we propose a reciprocally-benefited secure transmission strategy, in which SN’s interference to the eavesdropper is employed to protect the primary confidential messages while the CRSN is also rewarded with a loose spectrum sensing error probability constraint. Specifically, according to the spectrum sensing results and primary users’ activities, there are four system states in this strategy. For each state, we analyze the primary secrecy rate and the SN’s transmission rate by taking into account the spectrum sensing errors. Then, the SN’s transmit power is optimally allocated for each state so that the average transmission rate of CRSN is maximized under the constraint of the primary maximum permitted secrecy outage probability. In addition, the performance tradeoff between the transmission rate of CRSN and the primary secrecy outage probability is investigated. Moreover, we analyze the primary secrecy rate for the asymptotic scenarios and derive the closed-form expression of the SN’s transmission outage probability. Simulation results show that: (1) the performance of the SN’s average throughput in the proposed strategy outperforms the conventional overlay strategy; (2) both the primary network and CRSN benefit from the proposed strategy. PMID:27897988

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carpentier, J.L.; Di Bono, P.J.; Tournebise, P.J.

    The efficient bounding method for DC contingency analysis is improved using reciprocity properties. Knowing the consequences of the outage of a branch, these properties provide the consequences on that branch of various kinds of outages. This is used in order to reduce computation times and to get rid of some difficulties, such as those occurring when a branch flow is close to its limit before outage. Compensation, sparse vector, sparse inverse and bounding techniques are also used. A program has been implemented for single branch outages and tested on actual French EHV 650 bus network. Computation times are 60% ofmore » the Efficient Bounding method. The relevant algorithm is described in detail in the first part of this paper. In the second part, reciprocity properties and bounding formulas are extended for multiple branch outages and for multiple generator or load outages. An algorithm is proposed in order to handle all these cases simultaneously.« less

  5. Optimizing Storage and Renewable Energy Systems with REopt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elgqvist, Emma M.; Anderson, Katherine H.; Cutler, Dylan S.

    Under the right conditions, behind the meter (BTM) storage combined with renewable energy (RE) technologies can provide both cost savings and resiliency. Storage economics depend not only on technology costs and avoided utility rates, but also on how the technology is operated. REopt, a model developed at NREL, can be used to determine the optimal size and dispatch strategy for BTM or off-grid applications. This poster gives an overview of three applications of REopt: Optimizing BTM Storage and RE to Extend Probability of Surviving Outage, Optimizing Off-Grid Energy System Operation, and Optimizing Residential BTM Solar 'Plus'.

  6. Outage Probability Minimization for Energy Harvesting Cognitive Radio Sensor Networks

    PubMed Central

    Zhang, Fan; Jing, Tao; Huo, Yan; Jiang, Kaiwei

    2017-01-01

    The incorporation of cognitive radio (CR) capability in wireless sensor networks yields a promising network paradigm known as CR sensor networks (CRSNs), which is able to provide spectrum efficient data communication. However, due to the high energy consumption results from spectrum sensing, as well as subsequent data transmission, the energy supply for the conventional sensor nodes powered by batteries is regarded as a severe bottleneck for sustainable operation. The energy harvesting technique, which gathers energy from the ambient environment, is regarded as a promising solution to perpetually power-up energy-limited devices with a continual source of energy. Therefore, applying the energy harvesting (EH) technique in CRSNs is able to facilitate the self-sustainability of the energy-limited sensors. The primary concern of this study is to design sensing-transmission policies to minimize the long-term outage probability of EH-powered CR sensor nodes. We formulate this problem as an infinite-horizon discounted Markov decision process and propose an ϵ-optimal sensing-transmission (ST) policy through using the value iteration algorithm. ϵ is the error bound between the ST policy and the optimal policy, which can be pre-defined according to the actual need. Moreover, for a special case that the signal-to-noise (SNR) power ratio is sufficiently high, we present an efficient transmission (ET) policy and prove that the ET policy achieves the same performance with the ST policy. Finally, extensive simulations are conducted to evaluate the performance of the proposed policies and the impaction of various network parameters. PMID:28125023

  7. Outage Probability Minimization for Energy Harvesting Cognitive Radio Sensor Networks.

    PubMed

    Zhang, Fan; Jing, Tao; Huo, Yan; Jiang, Kaiwei

    2017-01-24

    The incorporation of cognitive radio (CR) capability in wireless sensor networks yields a promising network paradigm known as CR sensor networks (CRSNs), which is able to provide spectrum efficient data communication. However, due to the high energy consumption results from spectrum sensing, as well as subsequent data transmission, the energy supply for the conventional sensor nodes powered by batteries is regarded as a severe bottleneck for sustainable operation. The energy harvesting technique, which gathers energy from the ambient environment, is regarded as a promising solution to perpetually power-up energy-limited devices with a continual source of energy. Therefore, applying the energy harvesting (EH) technique in CRSNs is able to facilitate the self-sustainability of the energy-limited sensors. The primary concern of this study is to design sensing-transmission policies to minimize the long-term outage probability of EH-powered CR sensor nodes. We formulate this problem as an infinite-horizon discounted Markov decision process and propose an ϵ -optimal sensing-transmission (ST) policy through using the value iteration algorithm. ϵ is the error bound between the ST policy and the optimal policy, which can be pre-defined according to the actual need. Moreover, for a special case that the signal-to-noise (SNR) power ratio is sufficiently high, we present an efficient transmission (ET) policy and prove that the ET policy achieves the same performance with the ST policy. Finally, extensive simulations are conducted to evaluate the performance of the proposed policies and the impaction of various network parameters.

  8. Quantifying and Monetizing Renewable Energy Resiliency

    DOE PAGES

    Anderson, Kate H.; Laws, Nicholas D.; Marr, Spencer; ...

    2018-03-23

    Energy resiliency has been thrust to the forefront by recent severe weather events and natural disasters. Billions of dollars are lost each year due to power outages. This article highlights the unique value renewable energy hybrid systems (REHS), comprised of solar, energy storage, and generators, provide in increasing resiliency. We present a methodology to quantify the amount and value of resiliency provided by REHS, and ways to monetize this resiliency value through insurance premium discounts. A case study of buildings in New York City demonstrates how implementing REHS in place of traditional backup diesel generators can double the amount ofmore » outage survivability, with an added value of $781,200. For a Superstorm Sandy type event, results indicate that insurance premium reductions could support up to 4% of the capital cost of REHS, and the potential exists to prevent up to $2.5 billion in business interruption losses with increased REHS deployment.« less

  9. Quantifying and Monetizing Renewable Energy Resiliency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Kate H.; Laws, Nicholas D.; Marr, Spencer

    Energy resiliency has been thrust to the forefront by recent severe weather events and natural disasters. Billions of dollars are lost each year due to power outages. This article highlights the unique value renewable energy hybrid systems (REHS), comprised of solar, energy storage, and generators, provide in increasing resiliency. We present a methodology to quantify the amount and value of resiliency provided by REHS, and ways to monetize this resiliency value through insurance premium discounts. A case study of buildings in New York City demonstrates how implementing REHS in place of traditional backup diesel generators can double the amount ofmore » outage survivability, with an added value of $781,200. For a Superstorm Sandy type event, results indicate that insurance premium reductions could support up to 4% of the capital cost of REHS, and the potential exists to prevent up to $2.5 billion in business interruption losses with increased REHS deployment.« less

  10. Performance of multi-hop parallel free-space optical communication over gamma-gamma fading channel with pointing errors.

    PubMed

    Gao, Zhengguang; Liu, Hongzhan; Ma, Xiaoping; Lu, Wei

    2016-11-10

    Multi-hop parallel relaying is considered in a free-space optical (FSO) communication system deploying binary phase-shift keying (BPSK) modulation under the combined effects of a gamma-gamma (GG) distribution and misalignment fading. Based on the best path selection criterion, the cumulative distribution function (CDF) of this cooperative random variable is derived. Then the performance of this optical mesh network is analyzed in detail. A Monte Carlo simulation is also conducted to demonstrate the effectiveness of the results for the average bit error rate (ABER) and outage probability. The numerical result proves that it needs a smaller average transmitted optical power to achieve the same ABER and outage probability when using the multi-hop parallel network in FSO links. Furthermore, the system use of more number of hops and cooperative paths can improve the quality of the communication.

  11. A dynamic programming approach to estimate the capacity value of energy storage

    DOE PAGES

    Sioshansi, Ramteen; Madaeni, Seyed Hossein; Denholm, Paul

    2013-09-17

    Here, we present a method to estimate the capacity value of storage. Our method uses a dynamic program to model the effect of power system outages on the operation and state of charge of storage in subsequent periods. We combine the optimized dispatch from the dynamic program with estimated system loss of load probabilities to compute a probability distribution for the state of charge of storage in each period. This probability distribution can be used as a forced outage rate for storage in standard reliability-based capacity value estimation methods. Our proposed method has the advantage over existing approximations that itmore » explicitly captures the effect of system shortage events on the state of charge of storage in subsequent periods. We also use a numerical case study, based on five utility systems in the U.S., to demonstrate our technique and compare it to existing approximation methods.« less

  12. "Stronger than the Storm": Keeping Infants and Young Children in Mind During the Response to Superstorm Sandy

    ERIC Educational Resources Information Center

    Costa, Gerard; Mulrooney, Kathleen; Spinazzola, Nicci

    2013-01-01

    Superstorm Sandy hit the coast of New Jersey with deadly force causing hundreds of miles of coastline damage, loss of homes, property and road damage, and power outages throughout the region. despite the state's strong disaster response network, most programs and responders have little background in supporting the needs of infants and very young…

  13. Downlink Cooperative Broadcast Transmission Based on Superposition Coding in a Relaying System for Future Wireless Sensor Networks.

    PubMed

    Liu, Yang; Han, Guangjie; Shi, Sulong; Li, Zhengquan

    2018-06-20

    This study investigates the superiority of cooperative broadcast transmission over traditional orthogonal schemes when applied in a downlink relaying broadcast channel (RBC). Two proposed cooperative broadcast transmission protocols, one with an amplify-and-forward (AF) relay, and the other with a repetition-based decode-and-forward (DF) relay, are investigated. By utilizing superposition coding (SupC), the source and the relay transmit the private user messages simultaneously instead of sequentially as in traditional orthogonal schemes, which means the channel resources are reused and an increased channel degree of freedom is available to each user, hence the half-duplex penalty of relaying is alleviated. To facilitate a performance evaluation, theoretical outage probability expressions of the two broadcast transmission schemes are developed, based on which, we investigate the minimum total power consumption of each scheme for a given traffic requirement by numerical simulation. The results provide details on the overall system performance and fruitful insights on the essential characteristics of cooperative broadcast transmission in RBCs. It is observed that better overall outage performances and considerable power gains can be obtained by utilizing cooperative broadcast transmissions compared to traditional orthogonal schemes.

  14. Reduction of radiation exposure in Japanese BWR Nuclear Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morikawa, Yoshitake

    1995-03-01

    The reduction of occupational exposure to radiation during the annual inspection and maintenance outages of Japanese boiling water reactors (BWR) is one of the most important objectives for stable and reliable operation. It was shown that this radiation exposure is caused by radionuclides, such as Co-60, Co-58 and Mn-54 which are produced from the metal elements Co, Ni, and Fe present in the corrosion products of structural materials that had been irradiated by neutrons. Therefore, to reduce radiation sources and exposures in Japanese BWRs, attempts have been reinforced to remove corrosion products and activated corrosion products from the primary coolantmore » system. This paper describes the progress of the application of these measures to Japanese BWRs. Most Japanese BWR-4 and BWR-5 type nuclear power plants started their commercial operations during the 1970s. With the elapse of time during operations, a problem came to the forefront, namely that occupational radiation exposure during plant outages gradually increased, which obstructed the smooth running of inspections and maintenance work. To overcome this problem, extensive studies to derive effective countermeasures for radiation exposure reduction were undertaken, based on the evaluation of the plants operation data.« less

  15. How individual traces and interactive timelines could support outage execution - Toward an outage historian concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parfouru, S.; De-Beler, N.

    2012-07-01

    In the context of a project that is designing innovative ICT-based solutions for the organizational concept of outage management, we focus on the informational process of the OCR (Outage Control Room) underlying the execution of the outages. Informational process are based on structured and unstructured documents that have a key role in the collaborative processes and management of the outage. We especially track the structured and unstructured documents, electronically or not, from creation to sharing. Our analysis allows us to consider that the individual traces produced by an individual participant with a specific role could be multi-purpose and support sharingmore » between participants without creating duplication of work. The ultimate goal is to be able to generate an outage historian, that is not just focused on highly structured information, which could be useful to improve the continuity of information between participants. We study the implementation of this approach through web technologies and social media tools to address this issue. We also investigate the issue of data access through interactive visualization timelines coupled with other modality's to assist users in the navigation and exploration of the proposed historian. (authors)« less

  16. Estimating the Propagation of Interdependent Cascading Outages with Multi-Type Branching Processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, Junjian; Ju, Wenyun; Sun, Kai

    In this paper, the multi-type branching process is applied to describe the statistics and interdependencies of line outages, the load shed, and isolated buses. The offspring mean matrix of the multi-type branching process is estimated by the Expectation Maximization (EM) algorithm and can quantify the extent of outage propagation. The joint distribution of two types of outages is estimated by the multi-type branching process via the Lagrange-Good inversion. The proposed model is tested with data generated by the AC OPA cascading simulations on the IEEE 118-bus system. The largest eigenvalues of the offspring mean matrix indicate that the system ismore » closer to criticality when considering the interdependence of different types of outages. Compared with empirically estimating the joint distribution of the total outages, good estimate is obtained by using the multitype branching process with a much smaller number of cascades, thus greatly improving the efficiency. It is shown that the multitype branching process can effectively predict the distribution of the load shed and isolated buses and their conditional largest possible total outages even when there are no data of them.« less

  17. Robust Rate Maximization for Heterogeneous Wireless Networks under Channel Uncertainties

    PubMed Central

    Xu, Yongjun; Hu, Yuan; Li, Guoquan

    2018-01-01

    Heterogeneous wireless networks are a promising technology in next generation wireless communication networks, which has been shown to efficiently reduce the blind area of mobile communication and improve network coverage compared with the traditional wireless communication networks. In this paper, a robust power allocation problem for a two-tier heterogeneous wireless networks is formulated based on orthogonal frequency-division multiplexing technology. Under the consideration of imperfect channel state information (CSI), the robust sum-rate maximization problem is built while avoiding sever cross-tier interference to macrocell user and maintaining the minimum rate requirement of each femtocell user. To be practical, both of channel estimation errors from the femtocells to the macrocell and link uncertainties of each femtocell user are simultaneously considered in terms of outage probabilities of users. The optimization problem is analyzed under no CSI feedback with some cumulative distribution function and partial CSI with Gaussian distribution of channel estimation error. The robust optimization problem is converted into the convex optimization problem which is solved by using Lagrange dual theory and subgradient algorithm. Simulation results demonstrate the effectiveness of the proposed algorithm by the impact of channel uncertainties on the system performance. PMID:29466315

  18. A study on reliability of power customer in distribution network

    NASA Astrophysics Data System (ADS)

    Liu, Liyuan; Ouyang, Sen; Chen, Danling; Ma, Shaohua; Wang, Xin

    2017-05-01

    The existing power supply reliability index system is oriented to power system without considering actual electricity availability in customer side. In addition, it is unable to reflect outage or customer’s equipment shutdown caused by instantaneous interruption and power quality problem. This paper thus makes a systematic study on reliability of power customer. By comparing with power supply reliability, reliability of power customer is defined and extracted its evaluation requirements. An indexes system, consisting of seven customer indexes and two contrast indexes, are designed to describe reliability of power customer from continuity and availability. In order to comprehensively and quantitatively evaluate reliability of power customer in distribution networks, reliability evaluation method is proposed based on improved entropy method and the punishment weighting principle. Practical application has proved that reliability index system and evaluation method for power customer is reasonable and effective.

  19. Fluidized bed operations survey summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lombardi, C.

    1996-12-31

    A fluidized bed operations survey summary is presented. The survey contains information on: forced outage causes; forced outage concerns ranked numerically; 1996 boiler operation and maintenance (O&M) concerns; 1997 boiler O&M concerns; fluidized bed capacity factor results; and fluidized bed total outage time.

  20. Development of an Overview Display to Allow Advanced Outage Control Center Management to Quickly Evaluate Outage Status

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    St Germain, Shawn Walter; Hugo, Jacques Victor

    This report describes recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the scientific principles that informed the development of the visualizations.

  1. 77 FR 63757 - Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-17

    ... Commission's Rules Regarding Outage Reporting to Interconnected Voice Over Internet Protocol Service Providers and Broadband Internet Service Providers AGENCY: Federal Communications Commission. ACTION: Final... Regarding Outage Reporting to Interconnected Voice Over Internet Protocol Service Providers and Broadband...

  2. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  3. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  4. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  5. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... submit electronically an Initial Communications Outage Report to the Commission. Not later than thirty days after discovering the outage, the provider shall submit electronically a Final Communications... cannot be obtained through any of the methods described, for whatever reason, then the provider shall...

  6. Power plant fault detection using artificial neural network

    NASA Astrophysics Data System (ADS)

    Thanakodi, Suresh; Nazar, Nazatul Shiema Moh; Joini, Nur Fazriana; Hidzir, Hidzrin Dayana Mohd; Awira, Mohammad Zulfikar Khairul

    2018-02-01

    The fault that commonly occurs in power plants is due to various factors that affect the system outage. There are many types of faults in power plants such as single line to ground fault, double line to ground fault, and line to line fault. The primary aim of this paper is to diagnose the fault in 14 buses power plants by using an Artificial Neural Network (ANN). The Multilayered Perceptron Network (MLP) that detection trained utilized the offline training methods such as Gradient Descent Backpropagation (GDBP), Levenberg-Marquardt (LM), and Bayesian Regularization (BR). The best method is used to build the Graphical User Interface (GUI). The modelling of 14 buses power plant, network training, and GUI used the MATLAB software.

  7. NOAA Weather Radio - SAME

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME FIPS (Federal Information Processing Standards) code changes and / or SAME location code changes

  8. A Remote Monitoring System for Voltage, Current, Power and Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Barakat, E.; Sinno, N.; Keyrouz, C.

    This paper presents a study and design of a monitoring system for the continuous measurement of electrical energy parameters such as voltage, current, power and temperature. This system is designed to monitor the data remotely over internet. The electronic power meter is based on a microcontroller from Microchip Technology Inc. PIC family. The design takes into consideration the correct operation in the event of an outage or brown out by recording the electrical values and the temperatures in EEPROM internally available in the microcontroller. Also a digital display is used to show the acquired measurements. A computer will remotely monitor the data over internet.

  9. Design Concepts for an Outage Control Center Information Dashboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hugo, Jacques Victor; St Germain, Shawn Walter; Thompson, Cheradan Jo

    The nuclear industry, and the business world in general, is facing a rapidly increasing amount of data to be dealt with on a daily basis. In the last two decades, the steady improvement of data storage devices and means to create and collect data along the way influenced the manner in which we deal with information. Most data is still stored without filtering and refinement for later use. Many functions at a nuclear power plant generate vast amounts of data, with scheduled and unscheduled outages being a prime example of a source of some of the most complex data setsmore » at the plant. To make matters worse, modern information and communications technology is making it possible to collect and store data faster than our ability to use it for making decisions. However, in most applications, especially outages, raw data has no value in itself; instead, managers, engineers and other specialists want to extract the information contained in it. The complexity and sheer volume of data could lead to information overload, resulting in getting lost in data that may be irrelevant to the task at hand, processed in an inappropriate way, or presented in an ineffective way. To prevent information overload, many data sources are ignored so production opportunities are lost because utilities lack the ability to deal with the enormous data volumes properly. Decision-makers are often confronted with large amounts of disparate, conflicting and dynamic information, which are available from multiple heterogeneous sources. Information and communication technologies alone will not solve this problem. Utilities need effective methods to exploit and use the hidden opportunities and knowledge residing in unexplored data resources. Superior performance before, during and after outages depends upon the right information being available at the right time to the right people. Acquisition of raw data is the easy part; instead, it is the ability to use advanced analytical, data processing and data visualization methods to turn the data into reliable information and comprehensible, actionable information. Techniques like data mining, filtering and analysis only work reliably for well-defined and well-understood problems. The path from data to decision is more complex. The ability to communicate knowledge during outages and emergent issues is crucial. This paper presents an approach to turn the unused data into an opportunity: applying principles from semiotics, human factors and visual analytics to transform the traditional way of processing outage data into media that will improve the collective situation awareness, knowledge, decisions, actions and overall performance of the entire outage team, and also support the reliability, quality and overall effectiveness of maintenance work. The application of the proposed visualization methods will become the medium of a semi-automated analytical process where humans and machines cooperate using their respective, distinct capabilities for the most effective results.« less

  10. NOAA Weather Radio

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME Search For Go NWS All NOAA Frequently Asked Questions This site offers a wealth of information on NOAA

  11. NOAA Weather Radio - All Hazards

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME Weather Service (NWS) warnings, watches, forecasts and other non-weather related hazard information 24

  12. A GPS coverage model

    NASA Technical Reports Server (NTRS)

    Skidmore, Trent A.

    1994-01-01

    The results of several case studies using the Global Positioning System coverage model developed at Ohio University are summarized. Presented are results pertaining to outage area, outage dynamics, and availability. Input parameters to the model include the satellite orbit data, service area of interest, geometry requirements, and horizon and antenna mask angles. It is shown for precision-landing Category 1 requirements that the planned GPS 21 Primary Satellite Constellation produces significant outage area and unavailability. It is also shown that a decrease in the user equivalent range error dramatically decreases outage area and improves the service availability.

  13. Exploring Crisis Management in U.S. Small Businesses

    NASA Astrophysics Data System (ADS)

    Williams, Jon

    As a critical infrastructure, the US electricity grid supplies electricity to 340 million people within eight separate regions. The power infrastructure is vulnerable to many types of disasters capable of severing supplies of electricity. The impact on the employees and communities when small- and medium-size enterprises are shut down due to disasters can be severe. The purpose of the quantitative comparative study was to explore small- and medium-size enterprises crisis management strategies in the case of power infrastructure vulnerabilities. Perceptions of small business leaders were probed about crisis management planning relevant to three secondary factors: prior experience of crises, threat perceptions, and planning self-efficacy. Participants completed an adapted questionnaire instrument based on a five-point Likert scale for six sub-factors including resilience through planning, financial impact, operational crisis management, the perfect storm, the aftermath of survival, and atrophy. The instrument also measured three additional factors to include, prior experience of crises, threat perceptions, and planning self-efficacy, across seven types of crises. The results of this study indicated that of the 276 respondents, 104 had no crisis plans, but 172 did have crisis plans. Of those who had implemented crisis plans, 19% had specific provisions to address power outages or attacks on the electrical grid. Of the respondents who had not planned for power outages nor experienced significant losses of power, a statistically significant number acknowledged an external threat to their business. The majority of respondents indicated that long-term planning was related to resilience; however, the migration of crisis understanding into the planning process or implementation was not implemented. This heightened awareness of potential crises without the corresponding development and implementation of mitigation crisis plans requires additional research to understand drivers effecting the decision making process with crisis managers.

  14. NOAA Weather Radio - Voice of NWS

    Science.gov Websites

    Station Search Coverage Maps Outages View Outages Report Outages Information General Information Receiver Information Reception Problems NWR Alarms Automated Voices FIPS Codes NWR - Special Needs SAME USING SAME SAME information 24 hours a day. Known as the "voice of the National Weather Service," NWR is provided as

  15. 47 CFR 4.5 - Definitions of outage, special offices and facilities, and 911 special facilities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... facilities, and 911 special facilities. 4.5 Section 4.5 Telecommunication FEDERAL COMMUNICATIONS COMMISSION... Definitions of outage, special offices and facilities, and 911 special facilities. (a) Outage is defined as a... government facilities.” 911 special facilities are addressed separately in paragraph (e) of this section. (c...

  16. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS....7 Definitions of metrics used to determine the general outage-reporting threshold criteria. (a...

  17. Cyber attacks against state estimation in power systems: Vulnerability analysis and protection strategies

    NASA Astrophysics Data System (ADS)

    Liu, Xuan

    Power grid is one of the most critical infrastructures in a nation and could suffer a variety of cyber attacks. With the development of Smart Grid, false data injection attack has recently attracted wide research interest. This thesis proposes a false data attack model with incomplete network information and develops optimal attack strategies for attacking load measurements and the real-time topology of a power grid. The impacts of false data on the economic and reliable operations of power systems are quantitatively analyzed in this thesis. To mitigate the risk of cyber attacks, a distributed protection strategies are also developed. It has been shown that an attacker can design false data to avoid being detected by the control center if the network information of a power grid is known to the attacker. In practice, however, it is very hard or even impossible for an attacker to obtain all network information of a power grid. In this thesis, we propose a local load redistribution attacking model based on incomplete network information and show that an attacker only needs to obtain the network information of the local attacking region to inject false data into smart meters in the local region without being detected by the state estimator. A heuristic algorithm is developed to determine a feasible attacking region by obtaining reduced network information. This thesis investigates the impacts of false data on the operations of power systems. It has been shown that false data can be designed by an attacker to: 1) mask the real-time topology of a power grid; 2) overload a transmission line; 3) disturb the line outage detection based on PMU data. To mitigate the risk of cyber attacks, this thesis proposes a new protection strategy, which intends to mitigate the damage effects of false data injection attacks by protecting a small set of critical measurements. To further reduce the computation complexity, a mixed integer linear programming approach is also proposed to separate the power grid into several subnetworks, then distributed protection strategy is applied to each subnetwork.

  18. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Use of natural gas or petroleum for certain unanticipated... Natural Gas or Petroleum for Emergency and Unanticipated Equipment Outage Purposes § 501.191 Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies defined in section...

  19. 10 CFR 501.191 - Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Use of natural gas or petroleum for certain unanticipated... Natural Gas or Petroleum for Emergency and Unanticipated Equipment Outage Purposes § 501.191 Use of natural gas or petroleum for certain unanticipated equipment outages and emergencies defined in section...

  20. Joint Transmit Antenna Selection and Power Allocation for ISDF Relaying Mobile-to-Mobile Sensor Networks

    PubMed Central

    Xu, Lingwei; Zhang, Hao; Gulliver, T. Aaron

    2016-01-01

    The outage probability (OP) performance of multiple-relay incremental-selective decode-and-forward (ISDF) relaying mobile-to-mobile (M2M) sensor networks with transmit antenna selection (TAS) over N-Nakagami fading channels is investigated. Exact closed-form OP expressions for both optimal and suboptimal TAS schemes are derived. The power allocation problem is formulated to determine the optimal division of transmit power between the broadcast and relay phases. The OP performance under different conditions is evaluated via numerical simulation to verify the analysis. These results show that the optimal TAS scheme has better OP performance than the suboptimal scheme. Further, the power allocation parameter has a significant influence on the OP performance. PMID:26907282

  1. GRID INDEPENDENT FUEL CELL OPERATED SMART HOME

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dr. Mohammad S. Alam

    2003-12-07

    A fuel cell power plant, which utilizes a smart energy management and control (SEMaC) system, supplying the power need of laboratory based ''home'' has been purchased and installed. The ''home'' consists of two rooms, each approximately 250 sq. ft. Every appliance and power outlet is under the control of a host computer, running the SEMaC software package. It is possible to override the computer, in the event that an appliance or power outage is required. Detailed analysis and simulation of the fuel cell operated smart home has been performed. Two journal papers has been accepted for publication and another journalmore » paper is under review. Three theses have been completed and three additional theses are in progress.« less

  2. Grid-connected photovoltaic (PV) systems with batteries storage as solution to electrical grid outages in Burkina Faso

    NASA Astrophysics Data System (ADS)

    Abdoulaye, D.; Koalaga, Z.; Zougmore, F.

    2012-02-01

    This paper deals with a key solution for power outages problem experienced by many African countries and this through grid-connected photovoltaic (PV) systems with batteries storage. African grids are characterized by an insufficient power supply and frequent interruptions. Due to this fact, users who especially use classical grid-connected photovoltaic systems are unable to profit from their installation even if there is sun. In this study, we suggest the using of a grid-connected photovoltaic system with batteries storage as a solution to these problems. This photovoltaic system works by injecting the surplus of electricity production into grid and can also deliver electricity as a stand-alone system with all security needed. To achieve our study objectives, firstly we conducted a survey of a real situation of one African electrical grid, the case of Burkina Faso (SONABEL: National Electricity Company of Burkina). Secondly, as study case, we undertake a sizing, a modeling and a simulation of a grid-connected PV system with batteries storage for the LAME laboratory at the University of Ouagadougou. The simulation shows that the proposed grid-connected system allows users to profit from their photovoltaic installation at any time even if the public electrical grid has some failures either during the day or at night.

  3. INTEGRATED MONITORING HARDWARE DEVELOPMENTS AT LOS ALAMOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. PARKER; J. HALBIG; ET AL

    1999-09-01

    The hardware of the integrated monitoring system supports a family of instruments having a common internal architecture and firmware. Instruments can be easily configured from application-specific personality boards combined with common master-processor and high- and low-voltage power supply boards, and basic operating firmware. The instruments are designed to function autonomously to survive power and communication outages and to adapt to changing conditions. The personality boards allow measurement of gross gammas and neutrons, neutron coincidence and multiplicity, and gamma spectra. In addition, the Intelligent Local Node (ILON) provides a moderate-bandwidth network to tie together instruments, sensors, and computers.

  4. Saving Power at Peak Hours (LBNL Science at the Theater)

    ScienceCinema

    Piette, Mary Ann [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2018-05-23

    California needs new, responsive, demand-side energy technologies to ensure that periods of tight electricity supply on the grid don't turn into power outages. Led by Berkeley Lab's Mary Ann Piette, the California Energy Commission (through its Public Interest Energy Research Program) has established a Demand Response Research Center that addresses two motivations for adopting demand responsiveness: reducing average electricity prices and preventing future electricity crises. The research seeks to understand factors that influence "what works" in Demand Response. Piette's team is investigating the two types of demand response, load response and price response, that may influence and reduce the use of peak electric power through automated controls, peak pricing, advanced communications, and other strategies.

  5. Computer-controlled wall servicing robot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lefkowitz, S.

    1995-03-01

    After four years of cooperative research, Pentek has unveiled a new robot with the capability to automatically deliver a variety of cleaning, painting, inspection, and surveillance devices to large vertical surfaces. The completely computer-controlled robot can position a working tool on a 50-foot tall by 50-foot wide vertical surface with a repeatability of 1/16 inch. The working end can literally {open_quotes}fly{close_quotes} across the face of a wall at speed of 60 per minute, and can handle working loads of 350 pounds. The robot was originally developed to decontaminate the walls of reactor fueling cavities at commercial nuclear power plants duringmore » fuel outages. If these cavities are left to dry after reactor refueling, contamination present in the residue could later become airborne and move throughout the containment building. Decontaminating the cavity during the refueling outage reduces the need for restrictive personal protective equipment during plant operations to limit the dose rates.« less

  6. 77 FR 3543 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-24

    ... discuss the results of a circumstance in which there is a CBOE System outage or other interruption of... Exchange proposes to add a stipulation that in the event of a CBOE System outage or other interruption of... has twenty trading days, but a CBOE System outage occurs for one-half of one trading day, and a TPH...

  7. Scenario and multiple criteria decision analysis for energy and environmental security of military and industrial installations.

    PubMed

    Karvetski, Christopher W; Lambert, James H; Linkov, Igor

    2011-04-01

    Military and industrial facilities need secure and reliable power generation. Grid outages can result in cascading infrastructure failures as well as security breaches and should be avoided. Adding redundancy and increasing reliability can require additional environmental, financial, logistical, and other considerations and resources. Uncertain scenarios consisting of emergent environmental conditions, regulatory changes, growth of regional energy demands, and other concerns result in further complications. Decisions on selecting energy alternatives are made on an ad hoc basis. The present work integrates scenario analysis and multiple criteria decision analysis (MCDA) to identify combinations of impactful emergent conditions and to perform a preliminary benefits analysis of energy and environmental security investments for industrial and military installations. Application of a traditional MCDA approach would require significant stakeholder elicitations under multiple uncertain scenarios. The approach proposed in this study develops and iteratively adjusts a scoring function for investment alternatives to find the scenarios with the most significant impacts on installation security. A robust prioritization of investment alternatives can be achieved by integrating stakeholder preferences and focusing modeling and decision-analytical tools on a few key emergent conditions and scenarios. The approach is described and demonstrated for a campus of several dozen interconnected industrial buildings within a major installation. Copyright © 2010 SETAC.

  8. Reserve valuation in electric power systems

    NASA Astrophysics Data System (ADS)

    Ruiz, Pablo Ariel

    Operational reliability is provided in part by scheduling capacity in excess of the load forecast. This reserve capacity balances the uncertain power demand with the supply in real time and provides for equipment outages. Traditionally, reserve scheduling has been ensured by enforcing reserve requirements in the operations planning. An alternate approach is to employ a stochastic formulation, which allows the explicit modeling of the sources of uncertainty. This thesis compares stochastic and reserve methods and evaluates the benefits of a combined approach for the efficient management of uncertainty in the unit commitment problem. Numerical studies show that the unit commitment solutions obtained for the combined approach are robust and superior with respect to the traditional approach. These robust solutions are especially valuable in areas with a high proportion of wind power, as their built-in flexibility allows the dispatch of practically all the available wind power while minimizing the costs of operation. The scheduled reserve has an economic value since it reduces the outage costs. In several electricity markets, reserve demand functions have been implemented to take into account the value of reserve in the market clearing process. These often take the form of a step-down function at the reserve requirement level, and as such they may not appropriately represent the reserve value. The value of reserve is impacted by the reliability, dynamic and stochastic characteristics of system components, the system operation policies, and the economic aspects such as the risk preferences of the demand. In this thesis, these aspects are taken into account to approximate the reserve value and construct reserve demand functions. Illustrative examples show that the demand functions constructed have similarities with those implemented in some markets.

  9. Arc burst pattern analysis fault detection system

    NASA Technical Reports Server (NTRS)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1997-01-01

    A method and apparatus are provided for detecting an arcing fault on a power line carrying a load current. Parameters indicative of power flow and possible fault events on the line, such as voltage and load current, are monitored and analyzed for an arc burst pattern exhibited by arcing faults in a power system. These arcing faults are detected by identifying bursts of each half-cycle of the fundamental current. Bursts occurring at or near a voltage peak indicate arcing on that phase. Once a faulted phase line is identified, a comparison of the current and voltage reveals whether the fault is located in a downstream direction of power flow toward customers, or upstream toward a generation station. If the fault is located downstream, the line is de-energized, and if located upstream, the line may remain energized to prevent unnecessary power outages.

  10. Refinery Outages

    EIA Publications

    2017-01-01

    EIA's latest analysis of planned refinery outages during the first half of 2017 finds that such outages are not expected to cause a shortfall in the supply of petroleum products including gasoline, jet fuel, and distillate fuel, relative to expected demand, either nationally or within any U.S. region. This result occurs notwithstanding the current high level of U.S. gasoline demand, which in 2016 was as high as or higher than in any past year.

  11. Novel Hybrid of LS-SVM and Kalman Filter for GPS/INS Integration

    NASA Astrophysics Data System (ADS)

    Xu, Zhenkai; Li, Yong; Rizos, Chris; Xu, Xiaosu

    Integration of Global Positioning System (GPS) and Inertial Navigation System (INS) technologies can overcome the drawbacks of the individual systems. One of the advantages is that the integrated solution can provide continuous navigation capability even during GPS outages. However, bridging the GPS outages is still a challenge when Micro-Electro-Mechanical System (MEMS) inertial sensors are used. Methods being currently explored by the research community include applying vehicle motion constraints, optimal smoother, and artificial intelligence (AI) techniques. In the research area of AI, the neural network (NN) approach has been extensively utilised up to the present. In an NN-based integrated system, a Kalman filter (KF) estimates position, velocity and attitude errors, as well as the inertial sensor errors, to output navigation solutions while GPS signals are available. At the same time, an NN is trained to map the vehicle dynamics with corresponding KF states, and to correct INS measurements when GPS measurements are unavailable. To achieve good performance it is critical to select suitable quality and an optimal number of samples for the NN. This is sometimes too rigorous a requirement which limits real world application of NN-based methods.The support vector machine (SVM) approach is based on the structural risk minimisation principle, instead of the minimised empirical error principle that is commonly implemented in an NN. The SVM can avoid local minimisation and over-fitting problems in an NN, and therefore potentially can achieve a higher level of global performance. This paper focuses on the least squares support vector machine (LS-SVM), which can solve highly nonlinear and noisy black-box modelling problems. This paper explores the application of the LS-SVM to aid the GPS/INS integrated system, especially during GPS outages. The paper describes the principles of the LS-SVM and of the KF hybrid method, and introduces the LS-SVM regression algorithm. Field test data is processed to evaluate the performance of the proposed approach.

  12. Uninterruptible power systems and other power protection equipment for electronic health care systems.

    PubMed

    Massey, J K

    1979-01-01

    The increasing usage of electronic instruments in health care systems invariably leads to some level of dependence on them. In order to maximize the utility of these tools a high degree of reliability is essential. Many of the failures being experienced in systems where electronic instruments are being utilized may be attributed not to a failure of the instrument itself but rather to the poor quality of the commercial power to which they are attached. In order to reduce the effects of power fluctuations and outages, some type of power protection equipment must be installed between the commercial power system and the instrument. This article discusses the types of "electronic noise" present on commercial power lines and the various types of equipment used to reduce its effect on electronic instrumentation. In general, the Uninterruptible Power System (UPS) is shown to be the most effective power buffering element for a health care environment. General terminology associated with specifications of a UPS is defined in the article and attached appendix.

  13. Cost of Lightning Strike Related Outages of Visual Navigational Aids at Airports in the United States

    NASA Astrophysics Data System (ADS)

    Rakas, J.; Nikolic, M.; Bauranov, A.

    2017-12-01

    Lightning storms are a serious hazard that can cause damage to vital human infrastructure. In aviation, lightning strikes cause outages to air traffic control equipment and facilities that result in major disruptions in the network, causing delays and financial costs measured in the millions of dollars. Failure of critical systems, such as Visual Navigational Aids (Visual NAVAIDS), are particularly dangerous since NAVAIDS are an essential part of landing procedures. Precision instrument approach, an operation utilized during the poor visibility conditions, utilizes several of these systems, and their failure leads to holding patterns and ultimately diversions to other airports. These disruptions lead to both ground and airborne delay. Accurate prediction of these outages and their costs is a key prerequisite for successful investment planning. The air traffic management and control sector need accurate information to successfully plan maintenance and develop a more robust system under the threat of increasing lightning rates. To analyze the issue, we couple the Remote Monitoring and Logging System (RMLS) database and the Aviation System Performance Metrics (ASPM) databases to identify lightning-induced outages, and connect them with weather conditions, demand and landing runway to calculate the total delays induced by the outages, as well as the number of cancellations and diversions. The costs are then determined by calculating direct costs to aircraft operators and costs of passengers' time for delays, cancellations and diversions. The results indicate that 1) not all NAVAIDS are created equal, and 2) outside conditions matter. The cost of an outage depends on the importance of the failed system and the conditions that prevailed before, during and after the failure. The outage that occurs during high demand and poor weather conditions is more likely to result in more delays and higher costs.

  14. Collocated tunable wavenumber sensor/actuators for smart structures

    NASA Astrophysics Data System (ADS)

    Jones, Lori

    1994-02-01

    Two actuator modules have just come out of burnout. This burnout took longer than anticipated due to power outages during January. The measurements on the smaller actuators have been repeated and agreed with the previously reported values within +/- 10%. Measurements made on a glued stack showed stiffening with increasing stress from a modulus of about 4 Mpsi at 1000 psi to 12 Mpsi at 10,000 psi applied stress -- this shows the advantage of the cofired actuator.

  15. Data-Logger Interface And Test Controller

    NASA Technical Reports Server (NTRS)

    Burch, Donnie R.

    1995-01-01

    Data-logger interface and test controller developed to enable automation of tests in conjunction with data-acquisition functions performed by data loggers that have output-switching capabilities. Includes relay logic circuits that remain deenergized until out-of-tolerance condition on any data channel discovered. Designed to be connected to Fluke model 2286A (or equivalent) data-logger system, which features 3 control channels with 6 data inputs per channel. Includes elapsed-time counter that keeps track of power outages.

  16. Coping with a MEDLIB-L service outage

    PubMed Central

    Brown, Christine D.; MacCall, Steven

    2001-01-01

    Objective: The study assessed the coping strategies of MEDLIB-L subscribers during an unexpected disruption in the list's service. Methods: An online survey of MEDLIB-L subscribers was performed following a six-day service outage in August 1999. Results: Respondents' information needs resulted in two distinct coping strategies. Subscribers without a recognized information need or an information need determined to be not pressing coped by waiting out the interruption. Subscribers with pressing information needs turned to alternative methods of resolving these needs. Conclusions: While most respondents missed the list and the assistance that it provided, many did not feel that the outage required significant coping strategies. The outage was viewed as a “minor stressor” and did not require secondary-level assessment of the availability and suitability of alternative resources. PMID:11837260

  17. Outage Probability of MRC for κ-μ Shadowed Fading Channels under Co-Channel Interference.

    PubMed

    Chen, Changfang; Shu, Minglei; Wang, Yinglong; Yang, Ming; Zhang, Chongqing

    2016-01-01

    In this paper, exact closed-form expressions are derived for the outage probability (OP) of the maximal ratio combining (MRC) scheme in the κ-μ shadowed fading channels, in which both the independent and correlated shadowing components are considered. The scenario assumes the received desired signals are corrupted by the independent Rayleigh-faded co-channel interference (CCI) and background white Gaussian noise. To this end, first, the probability density function (PDF) of the κ-μ shadowed fading distribution is obtained in the form of a power series. Then the incomplete generalized moment-generating function (IG-MGF) of the received signal-to-interference-plus-noise ratio (SINR) is derived in the closed form. By using the IG-MGF results, closed-form expressions for the OP of MRC scheme are obtained over the κ-μ shadowed fading channels. Simulation results are included to validate the correctness of the analytical derivations. These new statistical results can be applied to the modeling and analysis of several wireless communication systems, such as body centric communications.

  18. Outage Probability of MRC for κ-μ Shadowed Fading Channels under Co-Channel Interference

    PubMed Central

    Chen, Changfang; Shu, Minglei; Wang, Yinglong; Yang, Ming; Zhang, Chongqing

    2016-01-01

    In this paper, exact closed-form expressions are derived for the outage probability (OP) of the maximal ratio combining (MRC) scheme in the κ-μ shadowed fading channels, in which both the independent and correlated shadowing components are considered. The scenario assumes the received desired signals are corrupted by the independent Rayleigh-faded co-channel interference (CCI) and background white Gaussian noise. To this end, first, the probability density function (PDF) of the κ-μ shadowed fading distribution is obtained in the form of a power series. Then the incomplete generalized moment-generating function (IG-MGF) of the received signal-to-interference-plus-noise ratio (SINR) is derived in the closed form. By using the IG-MGF results, closed-form expressions for the OP of MRC scheme are obtained over the κ-μ shadowed fading channels. Simulation results are included to validate the correctness of the analytical derivations. These new statistical results can be applied to the modeling and analysis of several wireless communication systems, such as body centric communications. PMID:27851817

  19. Sample EP Flow Analysis of Severely Damaged Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werley, Kenneth Alan; McCown, Andrew William

    These are slides for a presentation at the working group meeting of the WESC SREMP Software Product Integration Team on sample EP flow analysis of severely damaged networks. The following topics are covered: ERCOT EP Transmission Model; Zoomed in to Houston and Overlaying StreetAtlas; EMPACT Solve/Dispatch/Shedding Options; QACS BaseCase Power Flow Solution; 3 Substation Contingency; Gen. & Load/100 Optimal Dispatch; Dispatch Results; Shed Load for Low V; Network Damage Summary; Estimated Service Areas (Potential); Estimated Outage Areas (potential).

  20. Loss of Load Probability Calculation for West Java Power System with Nuclear Power Plant Scenario

    NASA Astrophysics Data System (ADS)

    Azizah, I. D.; Abdullah, A. G.; Purnama, W.; Nandiyanto, A. B. D.; Shafii, M. A.

    2017-03-01

    Loss of Load Probability (LOLP) index showing the quality and performance of an electrical system. LOLP value is affected by load growth, the load duration curve, forced outage rate of the plant, number and capacity of generating units. This reliability index calculation begins with load forecasting to 2018 using multiple regression method. Scenario 1 with compositions of conventional plants produce the largest LOLP in 2017 amounted to 71.609 days / year. While the best reliability index generated in scenario 2 with the NPP amounted to 6.941 days / year in 2015. Improved reliability of systems using nuclear power more efficiently when compared to conventional plants because it also has advantages such as emission-free, inexpensive fuel costs, as well as high level of plant availability.

  1. Automated power management and control

    NASA Technical Reports Server (NTRS)

    Dolce, James L.

    1991-01-01

    A comprehensive automation design is being developed for Space Station Freedom's electric power system. A joint effort between NASA's Office of Aeronautics and Exploration Technology and NASA's Office of Space Station Freedom, it strives to increase station productivity by applying expert systems and conventional algorithms to automate power system operation. The initial station operation will use ground-based dispatches to perform the necessary command and control tasks. These tasks constitute planning and decision-making activities that strive to eliminate unplanned outages. We perceive an opportunity to help these dispatchers make fast and consistent on-line decisions by automating three key tasks: failure detection and diagnosis, resource scheduling, and security analysis. Expert systems will be used for the diagnostics and for the security analysis; conventional algorithms will be used for the resource scheduling.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piette, Mary Ann

    California needs new, responsive, demand-side energy technologies to ensure that periods of tight electricity supply on the grid don't turn into power outages. Led by Berkeley Lab's Mary Ann Piette, the California Energy Commission (through its Public Interest Energy Research Program) has established a Demand Response Research Center that addresses two motivations for adopting demand responsiveness: reducing average electricity prices and preventing future electricity crises. The research seeks to understand factors that influence "what works" in Demand Response. Piette's team is investigating the two types of demand response, load response and price response, that may influence and reduce the usemore » of peak electric power through automated controls, peak pricing, advanced communications, and other strategies.« less

  3. Diversity combining in laser Doppler vibrometry for improved signal reliability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dräbenstedt, Alexander

    2014-05-27

    Because of the speckle nature of the light reflected from rough surfaces the signal quality of a vibrometer suffers from varying signal power. Deep signal outages manifest themselves as noise bursts and spikes in the demodulated velocity signal. Here we show that the signal quality of a single point vibrometer can be substantially improved by diversity reception. This concept is widely used in RF communication and can be transferred into optical interferometry. When two statistically independent measurement channels are available which measure the same motion on the same spot, the probability for both channels to see a signal drop-out atmore » the same time is very low. We built a prototype instrument that uses polarization diversity to constitute two independent reception channels that are separately demodulated into velocity signals. Send and receive beams go through different parts of the aperture so that the beams can be spatially separated. The two velocity channels are mixed into one more reliable signal by a PC program in real time with the help of the signal power information. An algorithm has been developed that ensures a mixing of two or more channels with minimum resulting variance. The combination algorithm delivers also an equivalent signal power for the combined signal. The combined signal lacks the vast majority of spikes that are present in the raw signals and it extracts the true vibration information present in both channels. A statistical analysis shows that the probability for deep signal outages is largely decreased. A 60 fold improvement can be shown. The reduction of spikes and noise bursts reduces the noise in the spectral analysis of vibrations too. Over certain frequency bands a reduction of the noise density by a factor above 10 can be shown.« less

  4. Concerns and perceptions immediately following Superstorm Sandy: ratings for property damage were higher than for health issues

    PubMed Central

    Burger, Joanna; Gochfeld, Michael

    2015-01-01

    Governmental officials, health and safety professionals, early responders, and the public are interested in the perceptions and concerns of people faced with a crisis, especially during and immediately after a disaster strikes. Reliable information can lead to increased individual and community preparedness for upcoming crises. The objective of this research was to evaluate concerns of coastal and central New Jersey residents within the first 100 days of Superstorm Sandy’s landfall. Respondents living in central New Jersey and Jersey shore communities were differentially impacted by the storm, with shore residents having higher evacuation rates (47% vs. 13%), more flood waters in their homes, longer power outages (average 23 vs. 6 days), and longer periods without Internet (29 vs. 6 days). Ratings of concerns varied both among and within categories as a function of location (central vs. coastal New Jersey), stressor level (ranging from 1 to 3 for combinations of power outages, high winds, and flooding), and demographics. Respondents were most concerned about property damage, health, inconveniences, ecological services, and nuclear power plants in that order. Respondents from the shore gave higher ratings to the concerns within each major category, compared to those from central Jersey. Four findings have implications for understanding future risk, recovery, and resiliency: (1) respondents with the highest stressor level (level 3) were more concerned about water damage than others, (2) respondents with flood damage were more concerned about water drainage and mold than others, (3) respondents with the highest stressor levels rated all ecological services higher than others, and (4) shore respondents rated all ecological services higher than central Jersey residents. These data provide information to design future preparedness plans, improve resiliency for future severe weather events, and reduce public health risk. PMID:27011757

  5. Performance of Trellis Coded 256 QAM super-multicarrier modem VLSI's for SDH interface outage-free digital microwave radio

    NASA Astrophysics Data System (ADS)

    Aikawa, Satoru; Nakamura, Yasuhisa; Takanashi, Hitoshi

    1994-02-01

    This paper describes the performance of an outage free SXH (Synchronous Digital Hierarchy) interface 256 QAM modem. An outage free DMR (Digital Microwave Radio) is achieved by a high coding gain trellis coded SPORT QAM and Super Multicarrier modem. A new frame format and its associated circuits connect the outage free modem to the SDH interface. The newly designed VLSI's are key devices for developing the modem. As an overall modem performance, BER (bit error rate) characteristics and equipment signatures are presented. A coding gain of 4.7 dB (at a BER of 10(exp -4)) is obtained using SPORT 256 QAM and Viterbi decoding. This coding gain is realized by trellis coding as well as by increasing of transmission rate. Roll-off factor is decreased to maintain the same frequency occupation and modulation level as ordinary SDH 256 QAM modern.

  6. AMTEC powered residential furnace and auxiliary power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanenok, J.F. III; Sievers, R.K.

    1996-12-31

    Residential gas furnaces normally rely on utility grid electric power to operate the fans and/or the pumps used to circulate conditioned air or water and they are thus vulnerable to interruptions of utility grid service. Experience has shown that such interruptions can occur during the heating season, and can lead to serious consequences. A gas furnace coupled to an AMTEC conversion system retains the potential to produce heat and electricity (gas lines are seldom interrupted during power outages), and can save approximately $47/heating season compared to a conventional gas furnace. The key to designing a power system is understanding, andmore » predicting, the cell performance characteristics. The three main processes that must be understood and modeled to fully characterize an AMTEC cell are the electro-chemical, sodium vapor flow, and heat transfer. This paper will show the results of the most recent attempt to model the heat transfer in a multi-tube AMTEC cell and then discusses the conceptual design of a self-powered residential furnace.« less

  7. Margin and sensitivity methods for security analysis of electric power systems

    NASA Astrophysics Data System (ADS)

    Greene, Scott L.

    Reliable operation of large scale electric power networks requires that system voltages and currents stay within design limits. Operation beyond those limits can lead to equipment failures and blackouts. Security margins measure the amount by which system loads or power transfers can change before a security violation, such as an overloaded transmission line, is encountered. This thesis shows how to efficiently compute security margins defined by limiting events and instabilities, and the sensitivity of those margins with respect to assumptions, system parameters, operating policy, and transactions. Security margins to voltage collapse blackouts, oscillatory instability, generator limits, voltage constraints and line overloads are considered. The usefulness of computing the sensitivities of these margins with respect to interarea transfers, loading parameters, generator dispatch, transmission line parameters, and VAR support is established for networks as large as 1500 buses. The sensitivity formulas presented apply to a range of power system models. Conventional sensitivity formulas such as line distribution factors, outage distribution factors, participation factors and penalty factors are shown to be special cases of the general sensitivity formulas derived in this thesis. The sensitivity formulas readily accommodate sparse matrix techniques. Margin sensitivity methods are shown to work effectively for avoiding voltage collapse blackouts caused by either saddle node bifurcation of equilibria or immediate instability due to generator reactive power limits. Extremely fast contingency analysis for voltage collapse can be implemented with margin sensitivity based rankings. Interarea transfer can be limited by voltage limits, line limits, or voltage stability. The sensitivity formulas presented in this thesis apply to security margins defined by any limit criteria. A method to compute transfer margins by directly locating intermediate events reduces the total number of loadflow iterations required by each margin computation and provides sensitivity information at minimal additional cost. Estimates of the effect of simultaneous transfers on the transfer margins agree well with the exact computations for a network model derived from a portion of the U.S grid. The accuracy of the estimates over a useful range of conditions and the ease of obtaining the estimates suggest that the sensitivity computations will be of practical value.

  8. Reliability considerations of a fuel cell backup power system for telecom applications

    NASA Astrophysics Data System (ADS)

    Serincan, Mustafa Fazil

    2016-03-01

    A commercial fuel cell backup power unit is tested in real life operating conditions at a base station of a Turkish telecom operator. The fuel cell system responds to 256 of 260 electric power outages successfully, providing the required power to the base station. Reliability of the fuel cell backup power unit is found to be 98.5% at the system level. On the other hand, a qualitative reliability analysis at the component level is carried out. Implications of the power management algorithm on reliability is discussed. Moreover, integration of the backup power unit to the base station ecosystem is reviewed in the context of reliability. Impact of inverter design on the stability of the output power is outlined. Significant current harmonics are encountered when a generic inverter is used. However, ripples are attenuated significantly when a custom design inverter is used. Further, fault conditions are considered for real world case studies such as running out of hydrogen, a malfunction in the system, or an unprecedented operating scheme. Some design guidelines are suggested for hybridization of the backup power unit for an uninterrupted operation.

  9. Lightning location system supervising Swedish power transmission network

    NASA Technical Reports Server (NTRS)

    Melin, Stefan A.

    1991-01-01

    For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

  10. Packaging, Transportation and Recycling of NPP Condenser Modules - 12262

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polley, G.M.

    2012-07-01

    Perma-Fix was awarded contract from Energy Northwest for the packaging, transportation and disposition of the condenser modules, water boxes and miscellaneous metal, combustibles and water generated during the 2011 condenser replacement outage at the Columbia Generating Station. The work scope was to package the water boxes and condenser modules as they were removed from the facility and transfer them to the Perma-Fix Northwest facility for processing, recycle of metals and disposition. The condenser components were oversized and overweight (the condenser modules weighed ∼102,058 kg [225,000 lb]) which required special equipment for loading and transport. Additional debris waste was packaged inmore » inter-modals and IP-1 boxes for transport. A waste management plan was developed to minimize the generation of virtually any waste requiring landfill disposal. The Perma-Fix Northwest facility was modified to accommodate the ∼15 m [50-ft] long condenser modules and equipment was designed and manufactured to complete the disassembly, decontamination and release survey. The condenser modules are currently undergoing processing for free release to a local metal recycler. Over three millions pounds of metal will be recycled and over 95% of the waste generated during this outage will not require land disposal. There were several elements of this project that needed to be addressed during the preparation for this outage and the subsequent packaging, transportation and processing. - Staffing the project to support 24/7 generation of large components and other wastes. - The design and manufacture of the soft-sided shipping containers for the condenser modules that measured ∼15 m X 4 m X 3 m [50 ft X 13 ft X 10 ft] and weighed ∼102,058 kg [225,000 lbs] - Developing a methodology for loading the modules into the shipping containers. - Obtaining a transport vehicle for the modules. - Designing and modifying the processing facility. - Movement of the modules at the processing facility. If any of these issues were not adequately resolved prior to the start of the outage, costly delays would result and the re-start of the power plant could be impacted. The main focus of this project was to find successful methods for keeping this material out of the landfills and preserving the natural resources. In addition, this operation provided a significant cost savings to the public utility by minimizing landfill disposal. The onsite portion of the project has been completed without impact to the overall outage schedule. By the date of presentation, the majority of the waste from the condenser replacement project will have been processed and recycled. The goals for this project included helping Energy Northwest maintain the outage schedule, package and characterize waste compliantly, perform transportation activities in compliance with 49CFR (Ref-1), and minimize the waste disposal volume. During this condenser replacement project, over three millions pounds of waste was generated, packaged, characterized and transported without injury or incident. It is anticipated that 95% of the waste generated during this project will not require landfill disposal. All of the waste is scheduled to be processed, decontaminated and recycled by June of 2012. (authors)« less

  11. PFP Emergency Lighting Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BUSCH, M.S.

    2000-02-02

    NFPA 101, section 5-9 mandates that, where required by building classification, all designated emergency egress routes be provided with adequate emergency lighting in the event of a normal lighting outage. Emergency lighting is to be arranged so that egress routes are illuminated to an average of 1.0 footcandle with a minimum at any point of 0.1 footcandle, as measured at floor level. These levels are permitted to drop to 60% of their original value over the required 90 minute emergency lighting duration after a power outage. The Plutonium Finishing Plant (PFP) has two designations for battery powered egress lights ''Emergencymore » Lights'' are those battery powered lights required by NFPA 101 to provide lighting along officially designated egress routes in those buildings meeting the correct occupancy requirements. Emergency Lights are maintained on a monthly basis by procedure ZSR-12N-001. ''Backup Lights'' are battery powered lights not required by NFPA, but installed in areas where additional light may be needed. The Backup Light locations were identified by PFP Safety and Engineering based on several factors. (1) General occupancy and type of work in the area. Areas occupied briefly during a shiftly surveillance do not require backup lighting while a room occupied fairly frequently or for significant lengths of time will need one or two Backup lights to provide general illumination of the egress points. (2) Complexity of the egress routes. Office spaces with a standard hallway/room configuration will not require Backup Lights while a large room with several subdivisions or irregularly placed rooms, doors, and equipment will require Backup Lights to make egress safer. (3) Reasonable balance between the safety benefits of additional lighting and the man-hours/exposure required for periodic light maintenance. In some plant areas such as building 236-Z, the additional maintenance time and risk of contamination do not warrant having Backup Lights installed in all rooms. Sufficient light for egress is provided by existing lights located in the hallways.« less

  12. Shape Control of Solar Collectors Using Shape Memory Alloy Actuators

    NASA Technical Reports Server (NTRS)

    Lobitz, D. W.; Grossman, J. W.; Allen, J. J.; Rice, T. M.; Liang, C.; Davidson, F. M.

    1996-01-01

    Solar collectors that are focused on a central receiver are designed with a mechanism for defocusing the collector or disabling it by turning it out of the path of the sun's rays. This is required to avoid damaging the receiver during periods of inoperability. In either of these two cases a fail-safe operation is very desirable where during power outages the collector passively goes to its defocused or deactivated state. This paper is principally concerned with focusing and defocusing the collector in a fail-safe manner using shape memory alloy actuators. Shape memory alloys are well suited to this application in that once calibrated the actuators can be operated in an on/off mode using a minimal amount of electric power. Also, in contrast to other smart materials that were investigated for this application, shape memory alloys are capable of providing enough stroke at the appropriate force levels to focus the collector. Design and analysis details presented, along with comparisons to test data taken from an actual prototype, demonstrate that the collector can be repeatedly focused and defocused within accuracies required by typical solar energy systems. In this paper the design, analysis and testing of a solar collector which is deformed into its desired shape by shape memory alloy actuators is presented. Computations indicate collector shapes much closer to spherical and with smaller focal lengths can be achieved by moving the actuators inward to a radius of approximately 6 inches. This would require actuators with considerably more stroke and some alternate SMA actuators are currently under consideration. Whatever SMA actuator is finally chosen for this application, repeatability and fatigue tests will be required to investigate the long term performance of the actuator.

  13. Simulation of demand-response power management in smart city

    NASA Astrophysics Data System (ADS)

    Kadam, Kshitija

    Smart Grids manage energy efficiently through intelligent monitoring and control of all the components connected to the electrical grid. Advanced digital technology, combined with sensors and power electronics, can greatly improve transmission line efficiency. This thesis proposed a model of a deregulated grid which supplied power to diverse set of consumers and allowed them to participate in decision making process through two-way communication. The deregulated market encourages competition at the generation and distribution levels through communication with the central system operator. A software platform was developed and executed to manage the communication, as well for energy management of the overall system. It also demonstrated self-healing property of the system in case a fault occurs, resulting in an outage. The system not only recovered from the fault but managed to do so in a short time with no/minimum human involvement.

  14. 76 FR 16240 - Mandatory Reliability Standards for Interconnection Reliability Operating Limits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... Standards. The Reliability Standards were designed to prevent instability, uncontrolled separation, or... designed to prevent instability, uncontrolled separation, or cascading outages that adversely impact the... instability, uncontrolled separation, or cascading outages. See NERC Glossary, available at http://www.nerc...

  15. Statistical analysis of cascading failures in power grids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chertkov, Michael; Pfitzner, Rene; Turitsyn, Konstantin

    2010-12-01

    We introduce a new microscopic model of cascading failures in transmission power grids. This model accounts for automatic response of the grid to load fluctuations that take place on the scale of minutes, when optimum power flow adjustments and load shedding controls are unavailable. We describe extreme events, caused by load fluctuations, which cause cascading failures of loads, generators and lines. Our model is quasi-static in the causal, discrete time and sequential resolution of individual failures. The model, in its simplest realization based on the Directed Current description of the power flow problem, is tested on three standard IEEE systemsmore » consisting of 30, 39 and 118 buses. Our statistical analysis suggests a straightforward classification of cascading and islanding phases in terms of the ratios between average number of removed loads, generators and links. The analysis also demonstrates sensitivity to variations in line capacities. Future research challenges in modeling and control of cascading outages over real-world power networks are discussed.« less

  16. A Model of Small Capacity Power Plant in Tateli Village, North Sulawesi

    NASA Astrophysics Data System (ADS)

    Sangari, F. J.; Rompas, P. T. D.

    2017-03-01

    The electricity supply in North Sulawesi is still very limited so ubiquitous electric current outage. It makes rural communities have problems in life because most uses electrical energy. One of the solutions is a model of power plants to supply electricity in Tateli village, Minahasa, North Sulawesi, Indonesia. The objective of this research is to get the model that generate electrical energy for household needs through power plant that using a model of Picohydro with cross flow turbine in Tateli village. The method used the study of literature, survey the construction site of the power plant and the characteristics of the location being a place of research, analysis of hydropower ability and analyzing costs of power plant. The result showed that the design model of cross flow turbines used in pico-hydro hydropower installations is connected to a generator to produce electrical energy maximum of 3.29 kW for household needs. This analyze will be propose to local government of Minahasa, North Sulawesi, Indonesia to be followed.

  17. Hazards of geomagnetic storms

    USGS Publications Warehouse

    Herzog, D.C.

    1992-01-01

    Geomagnetic storms are large and sometimes rapid fluctuations in the Earth's magnetic field that are related to disturbances on the Sun's surface. Although it is not widely recognized, these transient magnetic disturbances can be a significant hazard to people and property. Many of us know that the intensity of the auroral lights increases during magnetic storms, but few people realize that these storms can also cause massive power outages, interrupt radio communications and satellite operations, increase corrosion in oil and gas pipelines, and lead to spuriously high rejection rates in the manufacture of sensitive electronic equipment. 

  18. Emergency Lighting System

    NASA Technical Reports Server (NTRS)

    1994-01-01

    When power outages occurred at Landmark Plastic Corporation, it took seven to twelve minutes for the primary mercury lamps to cool down enough to relight and two to seven minutes for the ELS incandescent lamps to relight. Production could not resume for as much as seven minutes. An article in NASA Tech Briefs describing the capabilities of photosensing devices led Landmark employee, Steve Keller to design a system now activated by any voltage loss in the main lamp circuit and coupled with photosensing devices used to keep them on until the primary mercury lamps reach full brightness.

  19. 75 FR 6339 - California Public Utilities Commission Petition for Rulemaking

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-09

    ... (NORS). The CPUC also requests password-protected access to California- specific disruption and outage... ``limited to California-specific disruption and outage data.'' NORS is the Web-based filing system through which certain communications providers submit reports to the Commission of disruptions to communications...

  20. Comparison of Aperture Averaging and Receiver Diversity Techniques for Free Space Optical Links in Presence of Turbulence and Various Weather Conditions

    NASA Astrophysics Data System (ADS)

    Kaur, Prabhmandeep; Jain, Virander Kumar; Kar, Subrat

    2014-12-01

    In this paper, we investigate the performance of a Free Space Optic (FSO) link considering the impairments caused by the presence of various weather conditions such as very clear air, drizzle, haze, fog, etc., and turbulence in the atmosphere. Analytic expression for the outage probability is derived using the gamma-gamma distribution for turbulence and accounting the effect of weather conditions using the Beer-Lambert's law. The effect of receiver diversity schemes using aperture averaging and array receivers on the outage probability is studied and compared. As the aperture diameter is increased, the outage probability decreases irrespective of the turbulence strength (weak, moderate and strong) and weather conditions. Similar effects are observed when the number of direct detection receivers in the array are increased. However, it is seen that as the desired level of performance in terms of the outage probability decreases, array receiver becomes the preferred choice as compared to the receiver with aperture averaging.

  1. Spectrum Sharing in an ISM Band: Outage Performance of a Hybrid DS/FH Spread Spectrum System with Beamforming

    NASA Astrophysics Data System (ADS)

    Li, Hanyu; Syed, Mubashir; Yao, Yu-Dong; Kamakaris, Theodoros

    2009-12-01

    This paper investigates spectrum sharing issues in the unlicensed industrial, scientific, and medical (ISM) bands. It presents a radio frequency measurement setup and measurement results in 2.4 GHz. It then develops an analytical model to characterize the coexistence interference in the ISM bands, based on radio frequency measurement results in the 2.4 GHz. Outage performance using the interference model is examined for a hybrid direct-sequence frequency-hopping spread spectrum system. The utilization of beamforming techniques in the system is also investigated, and a simplified beamforming model is proposed to analyze the system performance using beamforming. Numerical results show that beamforming significantly improves the system outage performance. The work presented in this paper provides a quantitative evaluation of signal outages in a spectrum sharing environment. It can be used as a tool in the development process for future dynamic spectrum access models as well as engineering designs for applications in unlicensed bands.

  2. Exact outage analysis of the effect of co-channel interference on secured multi-hop relaying networks

    NASA Astrophysics Data System (ADS)

    Quang Nguyen, Sang; Kong, Hyung Yun

    2016-11-01

    In this article, the presence of multi-hop relaying, eavesdropper and co-channel interference (CCI) in the same system model is investigated. Specifically, the effect of CCI on a secured multi-hop relaying network is studied, in which the source communicates with the destination via multi-relay-hopping under the presence of an eavesdropper and CCI at each node. The optimal relay at each cluster is selected to help forward the message from the source to the destination. We apply two relay selection approaches to such a system model, i.e. the optimal relay is chosen based on (1) the maximum channel gain from the transmitter to all relays in the desired cluster and (2) the minimum channel gain from the eavesdropper to all relays in each cluster. For the performance evaluation and comparison, we derived the exact closed form of the secrecy outage probability of the two approaches. That analysis is verified by Monte Carlo simulation. Finally, the effects of the number of hops, the transmit power at the source, relays and the external sources, the distance between the external sources and each node in the system, and the location of the eavesdropper are presented and discussed.

  3. Non-Orthogonal Multiple Access for Ubiquitous Wireless Sensor Networks.

    PubMed

    Anwar, Asim; Seet, Boon-Chong; Ding, Zhiguo

    2018-02-08

    Ubiquitous wireless sensor networks (UWSNs) have become a critical technology for enabling smart cities and other ubiquitous monitoring applications. Their deployment, however, can be seriously hampered by the spectrum available to the sheer number of sensors for communication. To support the communication needs of UWSNs without requiring more spectrum resources, the power-domain non-orthogonal multiple access (NOMA) technique originally proposed for 5th Generation (5G) cellular networks is investigated for UWSNs for the first time in this paper. However, unlike 5G networks that operate in the licensed spectrum, UWSNs mostly operate in unlicensed spectrum where sensors also experience cross-technology interferences from other devices sharing the same spectrum. In this paper, we model the interferences from various sources at the sensors using stochastic geometry framework. To evaluate the performance, we derive a theorem and present new closed form expression for the outage probability of the sensors in a downlink scenario under interference limited environment. In addition, diversity analysis for the ordered NOMA users is performed. Based on the derived outage probability, we evaluate the average link throughput and energy consumption efficiency of NOMA against conventional orthogonal multiple access (OMA) technique in UWSNs. Further, the required computational complexity for the NOMA users is presented.

  4. Method for Evaluation of Outage Probability on Random Access Channel in Mobile Communication Systems

    NASA Astrophysics Data System (ADS)

    Kollár, Martin

    2012-05-01

    In order to access the cell in all mobile communication technologies a so called random-access procedure is used. For example in GSM this is represented by sending the CHANNEL REQUEST message from Mobile Station (MS) to Base Transceiver Station (BTS) which is consequently forwarded as an CHANNEL REQUIRED message to the Base Station Controller (BSC). If the BTS decodes some noise on the Random Access Channel (RACH) as random access by mistake (so- called ‘phantom RACH') then it is a question of pure coincidence which èstablishment cause’ the BTS thinks to have recognized. A typical invalid channel access request or phantom RACH is characterized by an IMMEDIATE ASSIGNMENT procedure (assignment of an SDCCH or TCH) which is not followed by sending an ESTABLISH INDICATION from MS to BTS. In this paper a mathematical model for evaluation of the Power RACH Busy Threshold (RACHBT) in order to guaranty in advance determined outage probability on RACH is described and discussed as well. It focuses on Global System for Mobile Communications (GSM) however the obtained results can be generalized on remaining mobile technologies (ie WCDMA and LTE).

  5. Vibrational fatigue failures in short cantilevered piping with socket-welding fittings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, J.K.

    1996-12-01

    Approximately 80% of the vibrational fatigue failures in nuclear power plants have been caused by high cycle vibrational fatigue. Many of these failures have occurred in short, small bore (2 in. nominal diameter and smaller), unbraced, cantilevered piping with socket-welding fittings. The fatigue failures initiated in the socket welds. These failures have been unexpected, and have caused costly, unscheduled outages in some cases. In order to reduce the number of vibrational fatigue failures in these short cantilevered pipes, an acceleration based vibrational fatigue screening criteria was developed under Electric Power Research Institute (EPRI) sponsorship. In this paper, the acceleration basedmore » criteria will be compared to the results obtained from detailed dynamic modeling of a short, cantilevered pipe.« less

  6. Type B investigation of electrical fault in 351 Substation, December 4, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debban, H.L.; Shearer, C.A.; Boger, R.M.

    1995-02-01

    On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accidentmore » scenario, accident analysis, direct cause and root and contributing causes.« less

  7. Portable power supply options for positive airway pressure devices.

    PubMed

    Riaz, Muhammad; Certal, Victor; Camacho, Macario

    2015-01-01

    Patients with obstructive sleep apnea (OSA) often face the challenge of how to power their positive airway pressure (PAP) devices when alternating current power supplies are not available in remote areas with lack of electricity or frequent power outages. This article elucidates portable power supply options for PAP devices with the aim to increase alternative power source awareness among medical providers. A search of scientific databases (Medline, Scopus, Web of Science, Google Scholar, and the Cochrane Library) was carried out on the topic of alternative portable power supply options for treatment of OSA. Scientific databases listed above yielded only limited results. Most articles were found via Google search. These articles were reviewed for alternative power supply options for OSA patients when alternating current is not available. The power supply options in this article include lead-acid batteries (starter, marine and deep-cycle batteries), lithium ion batteries, solar kits, battery packs, backup power systems, portable generators, and travel-size PAP devices. There are several options to power PAP devices with direct current when alternating current is not available. Knowledgeable primary care physicians especially in rural and remote areas can help OSA patients improve PAP compliance in order to mitigate morbidity and long-term complications of OSA.

  8. The impact of turbulent renewable energy production on power grid stability and quality

    NASA Astrophysics Data System (ADS)

    Schmietendorf, Katrin; Peinke, Joachim; Kamps, Oliver

    2017-11-01

    Feed-in fluctuations induced by renewables are one of the key challenges to the stability and quality of electrical power grids. In particular short-term fluctuations disturb the system on a time scale, on which load balancing does not operate yet and the system is intrinsically governed by self-organized synchronization. Wind and solar power are known to be strongly non-Gaussian with intermittent increment statistics in these time scales. We investigate the impact of short-term wind fluctuations on the basis of a Kuramoto-like power grid model considering stability in terms of desynchronization and frequency and voltage quality aspects. We present a procedure to generate realistic feed-in fluctuations with temporal correlations, Kolmogorov power spectrum and intermittent increments. By comparison to correlated Gaussian noise of the same spectrum and Gaussian white noise, we found out that while the correlations are essential to capture the likelihood of severe outages, the intermittent nature of wind power has significant consequences on power quality: intermittency is directly transferred into frequency and voltage fluctuations yielding a novel type of fluctuations, which is beyond engineering status of knowledge.

  9. Energy markets : refinery outages can have varying gasoline price impacts, but gaps in federal data limit understanding of impacts.

    DOT National Transportation Integrated Search

    2009-07-01

    In 2008, GAO reported that, with : the exception of the period : following Hurricanes Katrina and : Rita, refinery outages in the United : States did not show discernible : trends in reduced production : capacity, frequency, and location : from 2002 ...

  10. Economic and Environmental Impacts of the Columbia-Snake River Extended Lock Outage

    DOT National Transportation Integrated Search

    2012-03-01

    This reports main objective is to analyze the change in rates and modal costs for shippers, commodity industries and ports prior to, during and after the fifteen week lock outage and to determine the impacts on the environment in the form of energ...

  11. Natural hazard impact on the technosphere: "blackouts

    NASA Astrophysics Data System (ADS)

    Petrova, E. G.

    2012-04-01

    In recent years, natural-technological accidents (NTA) and disasters are increasing in their number and severity all over the world. The term "natural-technological accident (disaster)" applies for an accident (disaster) in the technosphere triggered by any natural process or phenomenon. Their growth is caused, on the one hand, by observed increasing in the frequency and intensity of some natural hazards and hazardous events due to climate change and, on the other hand, by a growing complication of the modern technosphere exposed to natural impacts and advancement of economic activities into the area at natural risk. The most large-scaled natural-technological disaster happened on March 11, 2011 in Japan, as a result of a massive earthquake and tsunami that caused a number of serious technological accidents, including accidents at "Fukushima-1" nuclear power plant, etc. Severe social, ecological and economic consequences of large-scaled NTA make investigation of these events especially important. The most frequent among NTA occurring in Russia are breakdowns in electric power supply systems that lead to so-called "blackouts" (accidental power outages). They are mainly caused by strong winds, snowstorms, deposition of ice, sleet, and snow, rainfalls, floods, and hailstones. Among other triggers earthquakes, hard frost, fierce heat, thunderstorms, landslides, snow avalanches, and debris flows should be mentioned. The great part of transmission facilities in Russia falls on overhead lines that are especially vulnerable to natural impacts. In general, natural triggers are responsible for more than 70 percent of all accidents in power supply systems. They occur more often in Far East, in the Southern and North-Western federal districts, and in some regions of the Central Russia, which are prone to hurricanes, cyclones, snowstorms, and heavy rainfalls accompanying by hailstones, icing, and sleet. A distinctive feature of these events is their synergistic nature, as power outages can cause a chain of other accidents at heat- and water supply, industrial plants, transport and communication facilities, producing so-called "domino effect". A modernization of facilities, replacement of overhead lines by underground cables and protection from falling trees can reduce the problem.

  12. High Fidelity, “Faster than Real-Time” Simulator for Predicting Power System Dynamic Behavior - Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flueck, Alex

    The “High Fidelity, Faster than Real­Time Simulator for Predicting Power System Dynamic Behavior” was designed and developed by Illinois Institute of Technology with critical contributions from Electrocon International, Argonne National Laboratory, Alstom Grid and McCoy Energy. Also essential to the project were our two utility partners: Commonwealth Edison and AltaLink. The project was a success due to several major breakthroughs in the area of large­scale power system dynamics simulation, including (1) a validated faster than real­ time simulation of both stable and unstable transient dynamics in a large­scale positive sequence transmission grid model, (2) a three­phase unbalanced simulation platform formore » modeling new grid devices, such as independently controlled single­phase static var compensators (SVCs), (3) the world’s first high fidelity three­phase unbalanced dynamics and protection simulator based on Electrocon’s CAPE program, and (4) a first­of­its­ kind implementation of a single­phase induction motor model with stall capability. The simulator results will aid power grid operators in their true time of need, when there is a significant risk of cascading outages. The simulator will accelerate performance and enhance accuracy of dynamics simulations, enabling operators to maintain reliability and steer clear of blackouts. In the long­term, the simulator will form the backbone of the newly conceived hybrid real­time protection and control architecture that will coordinate local controls, wide­area measurements, wide­area controls and advanced real­time prediction capabilities. The nation’s citizens will benefit in several ways, including (1) less down time from power outages due to the faster­than­real­time simulator’s predictive capability, (2) higher levels of reliability due to the detailed dynamics plus protection simulation capability, and (3) more resiliency due to the three­ phase unbalanced simulator’s ability to model three­phase and single­ phase networks and devices.« less

  13. MIMO capacities and outage probabilities in spatially multiplexed optical transport systems.

    PubMed

    Winzer, Peter J; Foschini, Gerard J

    2011-08-15

    With wavelength-division multiplexing (WDM) rapidly nearing its scalability limits, space-division multiplexing (SDM) seems the only option to further scale the capacity of optical transport networks. In order for SDM systems to continue the WDM trend of reducing energy and cost per bit with system capacity, integration will be key to SDM. Since integration is likely to introduce non-negligible crosstalk between multiple parallel transmission paths, multiple-input multiple output (MIMO) signal processing techniques will have to be used. In this paper, we discuss MIMO capacities in optical SDM systems, including related outage considerations which are an important part in the design of such systems. In order to achieve the low-outage standards required for optical transport networks, SDM transponders should be capable of individually addressing, and preferably MIMO processing all modes supported by the optical SDM waveguide. We then discuss the effect of distributed optical noise in MIMO SDM systems and focus on the impact of mode-dependent loss (MDL) on system capacity and system outage. Through extensive numerical simulations, we extract scaling rules for mode-average and mode-dependent loss and show that MIMO SDM systems composed of up to 128 segments and supporting up to 128 modes can tolerate up to 1 dB of per-segment MDL at 90% of the system's full capacity at an outage probability of 10(-4). © 2011 Optical Society of America

  14. New Innovations in Highly Ion Specific Media for Recalcitrant Waste stream Radioisotopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denton, M. S.; Wilson, J.; Ahrendt, M.

    Specialty ion specific media were examined and developed for, not only pre- and post-outage waste streams, but also for very difficult outage waste streams. This work was carried out on first surrogate waste streams, then laboratory samples of actual waste streams, and, finally, actual on-site waste streams. This study was particularly focused on PWR wastewaters such as Floor Drain Tank (FDT), Boron Waste Storage Tank (BWST), and Waste Treatment Tank (WTT, or discharge tank). Over the last half decade, or so, treatment technologies have so greatly improved and discharge levels have become so low, that certain particularly problematic isotopes, recalcitrantmore » to current treatment skids, are all that remain prior to discharge. In reality, they have always been present, but overshadowed by the more prevalent and higher activity isotopes. Such recalcitrants include cobalt, especially Co 58 [both ionic/soluble (total dissolved solids, TDS) and colloidal (total suspended solids, TSS)] and antimony (Sb). The former is present in most FDT and BWST wastewaters, while the Sb is primarily present in BWST waste streams. The reasons Co 58 can be elusive to granulated activated carbon (GAC), ultrafiltration (UF) and ion exchange (IX) demineralizers is that it forms submicron colloids as well as has a tendency to form metal complexes with chelating agents (e.g., ethylene diamine tetraacetic acid, or EDTA). Such colloids and non-charged complexes will pass through the entire treatment skid. Antimony (Sb) on the other hand, has little or no ionic charge, and will, likewise, pass through both the filtration and de-min skids into the discharge tanks. While the latter will sometimes (the anionic vs. the cationic or neutral species) be removed on the anion bed(s), it will slough off (snow-plow effect) when a higher affinity anion (iodine slugs, etc.) comes along; thus causing effluents not meeting discharge criteria. The answer to these problems found in this study, during an actual Nuclear Power Plant (NPP) outage cycle and recovery (four months), was the down-select and development of a number of highly ion specific media for the specific removal of such elusive isotopes. Over three dozen media including standard cation and anion ion exchangers, specialty IX, standard carbons, and, finally, chemically doped media (e.g., carbon and alumina substrates). The latter involved doping with iron, manganese, and even metals. The media down-select was carried out on actual plant waste streams so that all possible outage affects were accounted for, and distribution coefficients (Kd's) were determined (vs. decontamination factors, DF's, or percent removals). Such Kd's, in milliliters of solution per gram of media (mug), produce data indicative of the longevity of the media in that particular waste stream. Herein, the down-select is reported in Pareto (decreasing order) tables. Further affects such as the presence of high cobalt concentrations, high boron concentrations, the presence of hydrazine and chelating agents, and extreme pH conditions. Of particular importance here is to avoid the affinity of competing ions (e.g., a Sb specific media having more than a slight affinity for Co). The latter results in the snow-plow effect of sloughing off 3 to 4 times the cobalt into the effluent as was in the feed upon picking up the Sb. The study was quite successful and resulted in the development of and selection of a resin-type and two granular media for antimony removal, and two resin-types and a granular media for cobalt removal. The decontamination factors for both media were hundreds to thousands of times that of the full filtration and de-min. (authors)« less

  15. 47 CFR 63.71 - Procedures for discontinuance, reduction or impairment of service by domestic carriers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... impairment of service by domestic carriers. 63.71 Section 63.71 Telecommunication FEDERAL COMMUNICATIONS..., REDUCTION, OUTAGE AND IMPAIRMENT OF SERVICE BY COMMON CARRIERS; AND GRANTS OF RECOGNIZED PRIVATE OPERATING AGENCY STATUS Discontinuance, Reduction, Outage and Impairment § 63.71 Procedures for discontinuance...

  16. Air traffic control : good progress on interim replacement for outage-plagued system, but risks can be further reduced

    DOT National Transportation Integrated Search

    1996-10-01

    Certain air traffic control(ATC) centers experienced a series of major outages, : some of which were caused by the Display Channel Complex or DCC-a mainframe : computer system that processes radar and other data into displayable images on : controlle...

  17. 78 FR 6216 - Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-30

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 4 [PS Docket No. 11-82; DA 12-1962] Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over Internet Protocol Service Providers and Broadband Internet Service Providers AGENCY: Federal Communications Commission. ACTION: Final...

  18. Dynamically induced cascading failures in power grids.

    PubMed

    Schäfer, Benjamin; Witthaut, Dirk; Timme, Marc; Latora, Vito

    2018-05-17

    Reliable functioning of infrastructure networks is essential for our modern society. Cascading failures are the cause of most large-scale network outages. Although cascading failures often exhibit dynamical transients, the modeling of cascades has so far mainly focused on the analysis of sequences of steady states. In this article, we focus on electrical transmission networks and introduce a framework that takes into account both the event-based nature of cascades and the essentials of the network dynamics. We find that transients of the order of seconds in the flows of a power grid play a crucial role in the emergence of collective behaviors. We finally propose a forecasting method to identify critical lines and components in advance or during operation. Overall, our work highlights the relevance of dynamically induced failures on the synchronization dynamics of national power grids of different European countries and provides methods to predict and model cascading failures.

  19. Quantifying Power Grid Risk from Geomagnetic Storms

    NASA Astrophysics Data System (ADS)

    Homeier, N.; Wei, L. H.; Gannon, J. L.

    2012-12-01

    We are creating a statistical model of the geophysical environment that can be used to quantify the geomagnetic storm hazard to power grid infrastructure. Our model is developed using a database of surface electric fields for the continental United States during a set of historical geomagnetic storms. These electric fields are derived from the SUPERMAG compilation of worldwide magnetometer data and surface impedances from the United States Geological Survey. This electric field data can be combined with a power grid model to determine GICs per node and reactive MVARs at each minute during a storm. Using publicly available substation locations, we derive relative risk maps by location by combining magnetic latitude and ground conductivity. We also estimate the surface electric fields during the August 1972 geomagnetic storm that caused a telephone cable outage across the middle of the United States. This event produced the largest surface electric fields in the continental U.S. in at least the past 40 years.

  20. NOAA Weather Radio - Outage Reporting

    Science.gov Websites

    is not listed at Current Outages, the problem may be possibly be with your receiver. If your NWR receiver is not working properly or you need assistance in programming your NWR receiver, please click here information we may not be able to troubleshoot the problem fully. COVERAGE County Coverage Listings State

  1. 77 FR 25088 - Extension of the Commission's Rules Regarding Outage Reporting to Interconnected Voice Over...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ... Commission's rules to interconnected Voice over Internet Protocol (VoIP) service providers and defers action... to outages resulting from complete loss of service and only to interconnected VoIP services... obligations of interconnected VoIP service providers. DATES: The rules in this document contain information...

  2. Secure communication via an energy-harvesting untrusted relay in the presence of an eavesdropper

    NASA Astrophysics Data System (ADS)

    Tuan, Van Phu; Kong, Hyung Yun

    2018-02-01

    This article studies a secure communication of a simultaneous wireless information and power transfer system in which an energy-constrained untrusted relay, which harvests energy from the wireless signals, helps the communication between the source and destination and is able to decode the source's confidential signal. Additionally, the source's confidential signal is also overheard by a passive eavesdropper. To create positive secrecy capacity, a destination-assisted jamming signal that is completely cancelled at the destination is adopted. Moreover, the jamming signal is also exploited as an additional energy source. To evaluate the secrecy performance, analytical expressions for the secrecy outage probability (SOP) and the average secrecy capacity are derived. Moreover, a high-power approximation for the SOP is presented. The accuracy of the analytical results is verified by Monte Carlo simulations. Numerical results provide valuable insights into the effect of various system parameters, such as the energy-harvesting efficiency, secrecy rate threshold, power-splitting ratio, transmit powers, and locations of the relay and eavesdropper, on the secrecy performance.

  3. Low-cost wireless voltage & current grid monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hines, Jacqueline

    This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distributionmore » grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.« less

  4. Evaluation of the resilience of a full-scale down-flow hanging sponge reactor to long-term outages at a sewage treatment plant in India.

    PubMed

    Onodera, Takashi; Takayama, Daisuke; Ohashi, Akiyoshi; Yamaguchi, Takashi; Uemura, Shigeki; Harada, Hideki

    2016-10-01

    Resilience to process outages is an essential requirement for sustainable wastewater treatment systems in developing countries. In this study, we evaluated the ability of a full-scale down-flow hanging sponge (DHS) reactor to recover after a 10-day outage. The DHS tested in this study uses polyurethane sponge as packing material. This full-scale DHS reactor has been tested over a period of about 4 years in India with a flow rate of 500 m(3)/day. Water was not supplied to the DHS reactor that was subjected to the 10-day outage; however, the biomass did not dry out because the sponge was able to retain enough water. Soon after the reactor was restarted, a small quantity of biomass, amounting to only 0.1% of the total retained biomass, was eluted. The DHS effluent achieved satisfactory removal of suspended solids, chemical oxygen demand, and ammonium nitrogen within 90, 45, and 90 min, respectively. Conversely, fecal coliforms in the DHS effluent did not reach satisfactory levels within 540 min; instead, the normal levels of fecal coliforms were achieved within 3 days. Overall, the tests demonstrated that the DHS reactor was sufficiently robust to withstand long-term outages and achieved steady state soon after restart. This reinforces the suitability of this technology for developing countries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Predicting, examining, and evaluating FAC in US power plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cohn, M.J.; Garud, Y.S.; Raad, J. de

    1999-11-01

    There have been many pipe failures in fossil and nuclear power plant piping systems caused by flow-accelerated corrosion (FAC). In some piping systems, this failure mechanism maybe the most important type of damage to mitigate because FAC damage has led to catastrophic failures and fatalities. Detecting the damage and mitigating the problem can significantly reduce future forced outages and increase personnel safety. This article discusses the implementation of recent developments to select FAC inspection locations, perform cost-effective examinations, evaluate results, and mitigate FAC failures. These advances include implementing the combination of software to assist in selecting examination locations and anmore » improved pulsed eddy current technique to scan for wall thinning without removing insulation. The use of statistical evaluation methodology and possible mitigation strategies also are discussed.« less

  6. Modal Analysis for Grid Operation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MANGO software is to provide a solution for improving small signal stability of power systems through adjusting operator-controllable variables using PMU measurement. System oscillation problems are one of the major threats to the grid stability and reliability in California and the Western Interconnection. These problems result in power fluctuations, lower grid operation efficiency, and may even lead to large-scale grid breakup and outages. This MANGO software aims to solve this problem by automatically generating recommended operation procedures termed Modal Analysis for Grid Operation (MANGO) to improve damping of inter-area oscillation modes. The MANGO procedure includes three steps: recognizing small signalmore » stability problems, implementing operating point adjustment using modal sensitivity, and evaluating the effectiveness of the adjustment. The MANGO software package is designed to help implement the MANGO procedure.« less

  7. Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.

    2010-01-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the loadmore » and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. Currently, uncertainties associated with wind and load forecasts, as well as uncertainties associated with random generator outages and unexpected disconnection of supply lines, are not taken into account in power grid operation. Thus, operators have little means to weigh the likelihood and magnitude of upcoming events of power imbalance. In this project, funded by the U.S. Department of Energy (DOE), a framework has been developed for incorporating uncertainties associated with wind and load forecast errors, unpredicted ramps, and forced generation disconnections into the energy management system (EMS) as well as generation dispatch and commitment applications. A new approach to evaluate the uncertainty ranges for the required generation performance envelope including balancing capacity, ramping capability, and ramp duration has been proposed. The approach includes three stages: forecast and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence levels. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis, incorporating all sources of uncertainties of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the “flying brick” technique has been developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation algorithm has been developed to validate the accuracy of the confidence intervals.« less

  8. Licensed operating reactors: Status summary report, data as of December 31, 1995. Volume 20

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-06-01

    The US Nuclear Regulatory Commission`s monthly summary of licensed nuclear power reactor data is based primarily on the operating data report submitted by licensees for each unit. This report is divided into two sections: the first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1 availability factors, capacity factors, and forced outage rates are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensees and notes to the use of weighted averages and starting dates other than commercial operation are provided.

  9. 77 FR 41481 - Integration of Variable Energy Resources

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ...The Federal Energy Regulatory Commission is amending the pro forma Open Access Transmission Tariff to remove unduly discriminatory practices and to ensure just and reasonable rates for Commission- jurisdictional services. Specifically, this Final Rule removes barriers to the integration of variable energy resources by requiring each public utility transmission provider to: offer intra-hourly transmission scheduling; and, incorporate provisions into the pro forma Large Generator Interconnection Agreement requiring interconnection customers whose generating facilities are variable energy resources to provide meteorological and forced outage data to the public utility transmission provider for the purpose of power production forecasting.

  10. 47 CFR 4.9 - Outage reporting requirements-threshold criteria.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... call load data for the same day(s) of the week and the same time(s) of day as the outage, and for a... where, for whatever reason, real-time and historic carried call load data are unavailable to the provider, even after a detailed investigation, the provider must determine the carried call load based on...

  11. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  12. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  13. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  14. 47 CFR 4.7 - Definitions of metrics used to determine the general outage-reporting threshold criteria.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Definitions of metrics used to determine the general outage-reporting threshold criteria. 4.7 Section 4.7 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL DISRUPTIONS TO COMMUNICATIONS Reporting Requirements for Disruptions to Communications § 4.7 Definitions of metrics used to...

  15. Modernizing Distribution System Restoration to Achieve Grid Resiliency Against Extreme Weather Events: An Integrated Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chen; Wang, Jianhui; Ton, Dan

    Recent severe power outages caused by extreme weather hazards have highlighted the importance and urgency of improving the resilience of the electric power grid. As the distribution grids still remain vulnerable to natural disasters, the power industry has focused on methods of restoring distribution systems after disasters in an effective and quick manner. The current distribution system restoration practice for utilities is mainly based on predetermined priorities and tends to be inefficient and suboptimal, and the lack of situational awareness after the hazard significantly delays the restoration process. As a result, customers may experience an extended blackout, which causes largemore » economic loss. On the other hand, the emerging advanced devices and technologies enabled through grid modernization efforts have the potential to improve the distribution system restoration strategy. However, utilizing these resources to aid the utilities in better distribution system restoration decision-making in response to extreme weather events is a challenging task. Therefore, this paper proposes an integrated solution: a distribution system restoration decision support tool designed by leveraging resources developed for grid modernization. We first review the current distribution restoration practice and discuss why it is inadequate in response to extreme weather events. Then we describe how the grid modernization efforts could benefit distribution system restoration, and we propose an integrated solution in the form of a decision support tool to achieve the goal. The advantages of the solution include improving situational awareness of the system damage status and facilitating survivability for customers. The paper provides a comprehensive review of how the existing methodologies in the literature could be leveraged to achieve the key advantages. The benefits of the developed system restoration decision support tool include the optimal and efficient allocation of repair crews and resources, the expediting of the restoration process, and the reduction of outage durations for customers, in response to severe blackouts due to extreme weather hazards.« less

  16. Reliable and energy-efficient communications for wireless biomedical implant systems.

    PubMed

    Ntouni, Georgia D; Lioumpas, Athanasios S; Nikita, Konstantina S

    2014-11-01

    Implant devices are used to measure biological parameters and transmit their results to remote off-body devices. As implants are characterized by strict requirements on size, reliability, and power consumption, applying the concept of cooperative communications to wireless body area networks offers several benefits. In this paper, we aim to minimize the power consumption of the implant device by utilizing on-body wearable devices, while providing the necessary reliability in terms of outage probability and bit error rate. Taking into account realistic power considerations and wireless propagation environments based on the IEEE P802.l5 channel model, an exact theoretical analysis is conducted for evaluating several communication scenarios with respect to the position of the wearable device and the motion of the human body. The derived closed-form expressions are employed toward minimizing the required transmission power, subject to a minimum quality-of-service requirement. In this way, the complexity and power consumption are transferred from the implant device to the on-body relay, which is an efficient approach since they can be easily replaced, in contrast to the in-body implants.

  17. Automating Natural Disaster Impact Analysis: An Open Resource to Visually Estimate a Hurricane s Impact on the Electric Grid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barker, Alan M; Freer, Eva B; Omitaomu, Olufemi A

    An ORNL team working on the Energy Awareness and Resiliency Standardized Services (EARSS) project developed a fully automated procedure to take wind speed and location estimates provided by hurricane forecasters and provide a geospatial estimate on the impact to the electric grid in terms of outage areas and projected duration of outages. Hurricane Sandy was one of the worst US storms ever, with reported injuries and deaths, millions of people without power for several days, and billions of dollars in economic impact. Hurricane advisories were released for Sandy from October 22 through 31, 2012. The fact that the geoprocessing wasmore » automated was significant there were 64 advisories for Sandy. Manual analysis typically takes about one hour for each advisory. During a storm event, advisories are released every two to three hours around the clock, and an analyst capable of performing the manual analysis has other tasks they would like to focus on. Initial predictions of a big impact and landfall usually occur three days in advance, so time is of the essence to prepare for utility repair. Automated processing developed at ORNL allowed this analysis to be completed and made publicly available within minutes of each new advisory being released.« less

  18. Performance Analysis of Relay Subset Selection for Amplify-and-Forward Cognitive Relay Networks

    PubMed Central

    Qureshi, Ijaz Mansoor; Malik, Aqdas Naveed; Zubair, Muhammad

    2014-01-01

    Cooperative communication is regarded as a key technology in wireless networks, including cognitive radio networks (CRNs), which increases the diversity order of the signal to combat the unfavorable effects of the fading channels, by allowing distributed terminals to collaborate through sophisticated signal processing. Underlay CRNs have strict interference constraints towards the secondary users (SUs) active in the frequency band of the primary users (PUs), which limits their transmit power and their coverage area. Relay selection offers a potential solution to the challenges faced by underlay networks, by selecting either single best relay or a subset of potential relay set under different design requirements and assumptions. The best relay selection schemes proposed in the literature for amplify-and-forward (AF) based underlay cognitive relay networks have been very well studied in terms of outage probability (OP) and bit error rate (BER), which is deficient in multiple relay selection schemes. The novelty of this work is to study the outage behavior of multiple relay selection in the underlay CRN and derive the closed-form expressions for the OP and BER through cumulative distribution function (CDF) of the SNR received at the destination. The effectiveness of relay subset selection is shown through simulation results. PMID:24737980

  19. The human side of Hurricane Andrew

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, R.; Callander, R.C.

    1994-12-31

    This paper examines the long-term psychological effects of the nation`s worst natural disaster on the employees of the Turkey Point nuclear power plant. It also examines the efforts made by plant personnel and company volunteers to aid employees` families affected by the storm. Despite significant damage at the plant, unit 4 was returned to service 5 weeks after the August 24, 1992, hurricane. Unit 3 was returned to service on December 3, 1992. Unit 3 was originally scheduled to start a refueling outage the day Hurricane Andrew struck. While plant personnel are still recovering from Andrew`s impact, the plant`s performancemore » has never been better. On May 26, 1993, the plant completed a record-breaking 46-day refueling outage - 7 days ahead of schedule and $3 million under budget. Turkey Point`s recovery, return to service, and superior performance would not have been possible without the efforts of hundreds of employees who put their personal tragedies aside and focused on the common goal of the plant`s operation. To help employees with rebuilding their lives, the plant launched extensive assistance programs. Although the plant returned to normal operation, plant personnel continue to struggle in a community whose infrastructure (homes, schools, stores, etc.) have been almost eliminated.« less

  20. The design of optimal electric power demand management contracts

    NASA Astrophysics Data System (ADS)

    Fahrioglu, Murat

    1999-11-01

    Our society derives a quantifiable benefit from electric power. In particular, forced outages or blackouts have enormous consequences on society, one of which is loss of economic surplus. Electric utilities try to provide reliable supply of electric power to their customers. Maximum customer benefit derives from minimum cost and sufficient supply availability. Customers willing to share in "availability risk" can derive further benefit by participating in controlled outage programs. Specifically, whenever utilities foresee dangerous loading patterns, there is a need for a rapid reduction in demand either system-wide or at specific locations. The utility needs to get relief in order to solve its problems quickly and efficiently. This relief can come from customers who agree to curtail their loads upon request in exchange for an incentive fee. This thesis shows how utilities can get efficient load relief while maximizing their economic benefit. This work also shows how estimated customer cost functions can be calibrated, using existing utility data, to help in designing efficient demand management contracts. In order to design such contracts, optimal mechanism design is adopted from "Game Theory" and applied to the interaction between a utility and its customers. The idea behind mechanism design is to design an incentive structure that encourages customers to sign up for the right contract and reveal their true value of power. If a utility has demand management contracts with customers at critical locations, most operational problems can be solved efficiently. This thesis illustrates how locational attributes of customers incorporated into demand management contract design can have a significant impact in solving system problems. This kind of demand management contracts can also be used by an Independent System Operator (ISO). During times of congestion a loss of economic surplus occurs. When the market is too slow or cannot help relieve congestion, demand management can help solve the problem. Another tool the ISO requires for security purposes is reserves. Even though demand management contracts may not be a good substitute for spinning reserves, they are adequate to augment or replace supplemental and backup reserves.

  1. 77 FR 12096 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-28

    ... dealt with quickly and do not cause any client outages or connectivity issues. Due to the continuous... issues are dealt with quickly and do not cause any client outages or connectivity issues. Due to the... the Commission's Internet comment form ( http://www.sec.gov/rules/sro.shtml ); or Send an email to...

  2. Impact of Hurricane Sandy on community pharmacies in severely affected areas of New York City: A qualitative assessment.

    PubMed

    Arya, Vibhuti; Medina, Eric; Scaccia, Allison; Mathew, Cathleen; Starr, David

    2016-01-01

    Hurricane Sandy was one of the most severe natural disasters to hit the Mid-Atlantic States in recent history. Community pharmacies were among the businesses affected, with flooding and power outages significantly reducing services offered by many pharmacies. The objectives of our study were to assess the impact of Hurricane Sandy on community pharmacies, both independently owned and chain, in the severely affected areas of New York City (NYC), including Coney Island, Staten Island, and the Rockaways, using qualitative methods, and propose strategies to mitigate the impact of future storms and disasters. Of the total 52 solicited pharmacies, 35 (67 percent) responded and were included in our analysis. Only 10 (29 percent) of the pharmacies surveyed reported having a generator during Hurricane Sandy; 37 percent reported being equipped with a generator at the time of the survey approximately 1 year later. Our findings suggest that issues other than power outages contributed more toward a pharmacy remaining operational after the storm. Of those surveyed, 26 (74 percent) suffered from structural damage (most commonly in Coney Island). Most pharmacies (71 percent) were able to reopen within 1 month. Despite staffing challenges, most pharmacies (88 percent) had enough pharmacists/staff to resume normal operations. Overall, 91 percent were aware of law changes for emergency medication access, and 81 percent found the information easy to obtain. This survey helped inform our work toward improved community resiliency. Our findings have helped us recognize community pharmacists as important stakeholders and refocus our energy toward developing sustained partnerships with them in NYC as part of our ongoing preparedness strategy.

  3. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1. Volume 5: Analysis of core damage frequency from seismic events during mid-loop operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budnitz, R.J.; Davis, P.R.; Ravindra, M.K.

    1994-08-01

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1) and the other at Sandia National Laboratories studying a boiling water reactor (Grand Gulf). Both the Brookhaven and Sandia projects have examined only accidents initiated by internal plant faults--so-called ``internal initiators.`` This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling shutdown conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. Thismore » report covers the seismic analysis at Surry Unit 1. All of the many systems modeling assumptions, component non-seismic failure rates, and human error rates that were used in the internal-initiator study at Surry have been adopted here, so that the results of the two studies can be as comparable as possible. Both the Brookhaven study and this study examine only two shutdown plant operating states (POSs) during refueling outages at Surry, called POS 6 and POS 10, which represent mid-loop operation before and after refueling, respectively. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POSs 6 and 10. The results of the analysis are that the core-damage frequency of earthquake-initiated accidents during refueling outages in POS 6 and POS 10 is found to be low in absolute terms, less than 10{sup {minus}6}/year.« less

  4. A Comparative Study of Discovery Learning Scientific Community Laboratories and Traditional Laboratories in Physics at an Independent University, Florida, U. S

    NASA Astrophysics Data System (ADS)

    Reinhard, Karl E.

    Electric power is fully interwoven into the fabric of American life. Its loss for extended periods has profound impacts upon public safety, health and welfare. The power system has been termed the most complex machine built by man. Not surprisingly, the measures to address the range of power system downtime causes are as diverse as the causes themselves. One important arc of effort is providing power system operators with full knowledge of the system's operating state, timely warning when changing conditions threaten system stability, and tools guiding control actions to maintain stable operations. This research is motivated, in part, by the need to explore opportunities for leveraging nascent synchrophasor data streams against known power system stability challenges. Over the past half-decade, power system operators have aggressively installed large networks of phasor measurement units (PMUs) and phasor data concentrators (PDCs) across the United States and Canada. Today, the synchrophasor data network has reached a state of maturity that opens the door to useful application. This dissertation investigates power system stability along three lines of effort. The first two efforts address steady-state power system stability--specifically methods for assessing system vulnerabilities arising from the phase angle difference between two buses connected by a transmission line. The third effort investigates the information that can be gleaned from synchrophasor measurements during a system's dynamic system response to changing system conditions. The first line of investigation extends steady-state distribution factor theory. Distribution factors are computed from a known non-linear power system load flow solution. They provide a computationally light method for estimating new system conditions under different operating circumstances. Distribution factors are extremely useful for very rapidly screening the impact of unexpected changes in power system configuration--e.g. a transmission line dropping out of service due to environmental conditions. The Line Outage Angle Factor (LOAF) developed herein provides a method for fast computation of bus voltage angle changes after a line outage. The Line Outage Generator Factor (LOGF) modifies the simulated circuit topology to include synchronous machine transient reactances, enabling rapid screening of operating states in which line opening (or re-closure) risks damaging equipment. The LOAF and LOGF provide promising results in MATLAB simulation of the Western System Coordinating Council 3-Machine, 9-Bus System. The second investigative line seeks to develop a Thevenin equivalent model to be used in tandem with synchrophasor data streams to provide real-time bus angle difference information for buses connected by a transmission line. The appeal is that real-time bus angle difference information could be computed on-site and very rapidly--and significantly, independent of other network bus measurements. The results show that developing a Thevenin equivalent that provides a useful angle difference measure often works well on paper, but is challenging using actual synchrophasor data. Efforts to develop a Thevenin equivalent using Monte Carlo methods show promise, but require further investigation. The third line of effort shifts to investigate the useful information that a PMU can produce during a power system disturbance event. A synchrophasor is defined at a specific frequency, i.e. the system steady-state operating frequency. Thus a PMU produces a data stream recording power system changes progressing slower than the nominal system frequency; consequently, this is an "off-label" synchrophasor data application. The test system is a generator with electrical and mechanical controls connected by a pair of identical transmission lines to an infinite bus. The synchronous generator is modeled as a three-damper-winding synchronous machine. A MATLAB simulation was written to simulate both the full 14 dynamic state and the reduced order 11 dynamic state system models. A Real-Time Digital Simulator (RTDS) simulation emulating the test system provides the capability to produce real-time analog generator terminal waveforms to be sampled by a commercial off-the-shelf PMU to produce synchrophasor data. We find that the RTDS generated synchrophasor data stream is similar to the MATLAB reduced order model voltage and current generator terminal data in the dqo reference frame--reflecting parallel, but distinct, filtering processes.

  5. Optimal Sizing Tool for Battery Storage in Grid Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-09-24

    The battery storage sizing tool developed at Pacific Northwest National Laboratory can be used to evaluate economic performance and determine the optimal size of battery storage in different use cases considering multiple power system applications. The considered use cases include i) utility owned battery storage, and ii) battery storage behind customer meter. The power system applications from energy storage include energy arbitrage, balancing services, T&D deferral, outage mitigation, demand charge reduction etc. Most of existing solutions consider only one or two grid services simultaneously, such as balancing service and energy arbitrage. ES-select developed by Sandia and KEMA is able tomore » consider multiple grid services but it stacks the grid services based on priorities instead of co-optimization. This tool is the first one that provides a co-optimization for systematic and local grid services.« less

  6. Nuclear Power - Post Fukushima

    NASA Astrophysics Data System (ADS)

    Reyes, Jose, Jr.

    2011-10-01

    The extreme events that led to the prolonged power outage at the Fukushima Daiicchi nuclear plant have highlighted the importance of assuring a means for stable long term cooling of the nuclear fuel and containment following a complete station blackout. Legislative bodies, regulatory agencies and industry are drawing lessons from those events and considering what changes, if any, are needed to nuclear power, post Fukushima. The enhanced safety of a new class of reactor designed by NuScale Power is drawing significant attention in light of the Fukushima events. During normal operation, each NuScale containment is fully immersed in a water-filled stainless steel lined concrete pool that resides underground. The pool, housed in a Seismic Category I building, is large enough to provided 30 days of core and containment cooling without adding water. After 30 days, the decay heat generations coupled with thermal radiation heat transfer is completely adequate to remove core decay heat for an unlimited period of time. These passive power systems can perform their function without requiring an external supply of water of power. An assessment of the NuScale passive systems is being performed through a comprehensive test program that includes the NuScale integral system test facility at Oregon State University

  7. DOD fuel cell demonstration program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holcomb, F.H.; Binder, M.J.; Taylor, W.R.

    The supply of reliable, cost-effective electric power with minimal environmental impact is a constant concern of Department of Defense (DOD) installation energy personnel. Electricity purchased from the local utility is expensive and represents only about 30% of the original energy input at the generating station due to generation and distribution inefficiencies. Because of master metering and large air conditioning loads, the demand portion of the installation`s electric bill can be in excess of 50% of the total bill. While the electric utilities in the United States have a very good record of reliability, there is significant potential for improving themore » security of electrical power supplied by using on-site power generation. On-site, dispersed power generation can reduce power outages due to weather, terrorist activities, or lack of utility generating capacity. In addition, as increased emphasis is placed on global warming, acid rain, and air pollution in general, the development of clean, highly efficient power producing technologies is not only desirable, but mandatory. Since the majority of central heat plants on U.S. military installations are nearing the end of their useful life, there is an opportunity to replace outdated existing equipment with modem technologies.« less

  8. Correlating Inferred Data Plane IPV6 Reboot Events With Control Plane BGP Activity

    DTIC Science & Technology

    2016-03-01

    22 Figure 3.6 Example Border Gateway Protocol (BGP) update message . . . . 23 Figure 3.7 Customer-provider relationship with border...government USN U.S. Navy VPN Virtual Private Network xiv Acknowledgments First, I would like to thank my family for their love , support, and...network outages when they restart . Network outages occur for many reasons: hardware failure, severe weather, misconfiguration, patching, upgrades

  9. Bulk transmission system component outage data base. Research project 1283-1. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albrecht, P.F.; Heising, C.R.; Patton, A.D.

    1981-04-01

    This project is responsive to the premise that the successful analysis of equipment reliability and system adequacy in bulk transmission system planning and system operations requires data on equipment failure rates, maintenance outage rates and repair times. The objective of the project is to develop a system of consistent definitions, formats and procedures which can be used in the collection of such data in a well designed outage data bank. The project consisted of four interrelated phases, beginning with a review of related work and problem definition and ending with a discussion of data base organization and management. The reviewmore » of related work quickly pointed out that two schools of thought exist on data collection. One group contends that data should be collected on bulk transmission system physical equipments, such as transformers, circuit breakers, etc., and the other group supports data collection on functional transmission lines, including the terminal equipment, which have been defined as transmission units in this report. A compromise between these two approaches was imperative for successful completion of the work. The second phase investigated the data needed for reliability evaluation. The applications of the data bank were enumerated leading to a list of basic data needed when recording an incident. Phase 3 concentrated on developing procedures for data collection using forms to collect data both on outages and on the equipment design. Finally, the aspects of data base organization and management were explored and general recommendations made appropriate to this specific application. The project did not succeed in completely defining the procedures, particularly for multiple outages, but the ground work has been laid for a pilot data collection effort to refine the procedures before wide scale implementation by the utility industry.« less

  10. Empirical cost models for estimating power and energy consumption in database servers

    NASA Astrophysics Data System (ADS)

    Valdivia Garcia, Harold Dwight

    The explosive growth in the size of data centers, coupled with the widespread use of virtualization technology has brought power and energy consumption as major concerns for data center administrators. Provisioning decisions must take into consideration not only target application performance but also the power demands and total energy consumption incurred by the hardware and software to be deployed at the data center. Failure to do so will result in damaged equipment, power outages, and inefficient operation. Since database servers comprise one of the most popular and important server applications deployed in such facilities, it becomes necessary to have accurate cost models that can predict the power and energy demands that each database workloads will impose in the system. In this work we present an empirical methodology to estimate the power and energy cost of database operations. Our methodology uses multiple-linear regression to derive accurate cost models that depend only on readily available statistics such as selectivity factors, tuple size, numbers columns and relational cardinality. Moreover, our method does not need measurement of individual hardware components, but rather total power and energy consumption measured at a server. We have implemented our methodology, and ran experiments with several server configurations. Our experiments indicate that we can predict power and energy more accurately than alternative methods found in the literature.

  11. Naturalistic Decision Making for Power System Operators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greitzer, Frank L.; Podmore, Robin; Robinson, Marck

    2010-02-01

    Motivation – Investigations of large-scale outages in the North American interconnected electric system often attribute the causes to three T’s: Trees, Training and Tools. To document and understand the mental processes used by expert operators when making critical decisions, a naturalistic decision making (NDM) model was developed. Transcripts of conversations were analyzed to reveal and assess NDM-based performance criteria. Findings/Design – An item analysis indicated that the operators’ Situation Awareness Levels, mental models, and mental simulations can be mapped at different points in the training scenario. This may identify improved training methods or analytical/ visualization tools. Originality/Value – This studymore » applies for the first time, the concepts of Recognition Primed Decision Making, Situation Awareness Levels and Cognitive Task Analysis to training of electric power system operators. Take away message – The NDM approach provides a viable framework for systematic training management to accelerate learning in simulator-based training scenarios for power system operators and teams.« less

  12. Impacts of Wind and Solar on Fossil-Fueled Generators: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lew, D.; Brinkman, G.; Kumar, N.

    2012-08-01

    High penetrations of wind and solar power will impact the operations of the remaining generators on the power system. Regional integration studies have shown that wind and solar may cause fossil-fueled generators to cycle on and off and ramp down to part load more frequently and potentially more rapidly. Increased cycling, deeper load following, and rapid ramping may result in wear-and-tear impacts on fossil-fueled generators that lead to increased capital and maintenance costs, increased equivalent forced outage rates, and degraded performance over time. Heat rates and emissions from fossil-fueled generators may be higher during cycling and ramping than during steady-statemore » operation. Many wind and solar integration studies have not taken these increased cost and emissions impacts into account because data have not been available. This analysis considers the cost and emissions impacts of cycling and ramping of fossil-fueled generation to refine assessments of wind and solar impacts on the power system.« less

  13. Sequential Service Restoration for Unbalanced Distribution Systems and Microgrids

    DOE PAGES

    Chen, Bo; Chen, Chen; Wang, Jianhui; ...

    2017-07-07

    The resilience and reliability of modern power systems are threatened by increasingly severe weather events and cyber-physical security events. An effective restoration methodology is desired to optimally integrate emerging smart grid technologies and pave the way for developing self-healing smart grids. In this paper, a sequential service restoration (SSR) framework is proposed to generate restoration solutions for distribution systems and microgrids in the event of large-scale power outages. The restoration solution contains a sequence of control actions that properly coordinate switches, distributed generators, and switchable loads to form multiple isolated microgrids. The SSR can be applied for three-phase unbalanced distributionmore » systems and microgrids and can adapt to various operation conditions. Mathematical models are introduced for three-phase unbalanced power flow, voltage regulators, transformers, and loads. Furthermore, the SSR problem is formulated as a mixed-integer linear programming model, and its effectiveness is evaluated via the modified IEEE 123 node test feeder.« less

  14. Sequential Service Restoration for Unbalanced Distribution Systems and Microgrids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Bo; Chen, Chen; Wang, Jianhui

    The resilience and reliability of modern power systems are threatened by increasingly severe weather events and cyber-physical security events. An effective restoration methodology is desired to optimally integrate emerging smart grid technologies and pave the way for developing self-healing smart grids. In this paper, a sequential service restoration (SSR) framework is proposed to generate restoration solutions for distribution systems and microgrids in the event of large-scale power outages. The restoration solution contains a sequence of control actions that properly coordinate switches, distributed generators, and switchable loads to form multiple isolated microgrids. The SSR can be applied for three-phase unbalanced distributionmore » systems and microgrids and can adapt to various operation conditions. Mathematical models are introduced for three-phase unbalanced power flow, voltage regulators, transformers, and loads. Furthermore, the SSR problem is formulated as a mixed-integer linear programming model, and its effectiveness is evaluated via the modified IEEE 123 node test feeder.« less

  15. Rehabilitation of a 410-MW utility boiler at Costa Sur, Puerto Rico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosado, R.; Salmeron, M.

    1995-12-31

    To increase unit reliability and availability and to meet the current and future electric power demands in Puerto Rico, the Puerto Rico Electric Power Authority (PREPA) recently performed a scheduled outage rehabilitation of Costa Sur Power Station Unit 5. This major rehabilitation of a 23-year-old, 410 MW, oil-fired boiler was accompanied by the upgrading of the low-pressure turbine with new rotors. The boiler rehabilitation included the replacement of all waterwall floor panels from just below the burner windbox, down to the lower drum. Temporary support was provided for the lower drum and its structural system during the panel replacement. Themore » steam drum internals were completely rehabilitated, with the installation of a new liner and cleaning and repair of other internals as required. The superheater and reheater desuperheater liners were also replaced. In addition, all major components of both the firing system and the air preheaters were replaced. The gas recirculation fan was rehabilitated, and its discharge duct was replaced.« less

  16. Defining and Enabling Resiliency of Electric Distribution Systems With Multiple Microgrids

    DOE PAGES

    Chanda, Sayonsom; Srivastava, Anurag K.

    2016-05-02

    This paper presents a method for quantifying and enabling the resiliency of a power distribution system (PDS) using analytical hierarchical process and percolation theory. Using this metric, quantitative analysis can be done to analyze the impact of possible control decisions to pro-actively enable the resilient operation of distribution system with multiple microgrids and other resources. Developed resiliency metric can also be used in short term distribution system planning. The benefits of being able to quantify resiliency can help distribution system planning engineers and operators to justify control actions, compare different reconfiguration algorithms, develop proactive control actions to avert power systemmore » outage due to impending catastrophic weather situations or other adverse events. Validation of the proposed method is done using modified CERTS microgrids and a modified industrial distribution system. Furthermore, simulation results show topological and composite metric considering power system characteristics to quantify the resiliency of a distribution system with the proposed methodology, and improvements in resiliency using two-stage reconfiguration algorithm and multiple microgrids.« less

  17. A RLS-SVM Aided Fusion Methodology for INS during GPS Outages

    PubMed Central

    Yao, Yiqing; Xu, Xiaosu

    2017-01-01

    In order to maintain a relatively high accuracy of navigation performance during global positioning system (GPS) outages, a novel robust least squares support vector machine (LS-SVM)-aided fusion methodology is explored to provide the pseudo-GPS position information for the inertial navigation system (INS). The relationship between the yaw, specific force, velocity, and the position increment is modeled. Rather than share the same weight in the traditional LS-SVM, the proposed algorithm allocates various weights for different data, which makes the system immune to the outliers. Field test data was collected to evaluate the proposed algorithm. The comparison results indicate that the proposed algorithm can effectively provide position corrections for standalone INS during the 300 s GPS outage, which outperforms the traditional LS-SVM method. Historical information is also involved to better represent the vehicle dynamics. PMID:28245549

  18. A RLS-SVM Aided Fusion Methodology for INS during GPS Outages.

    PubMed

    Yao, Yiqing; Xu, Xiaosu

    2017-02-24

    In order to maintain a relatively high accuracy of navigation performance during global positioning system (GPS) outages, a novel robust least squares support vector machine (LS-SVM)-aided fusion methodology is explored to provide the pseudo-GPS position information for the inertial navigation system (INS). The relationship between the yaw, specific force, velocity, and the position increment is modeled. Rather than share the same weight in the traditional LS-SVM, the proposed algorithm allocates various weights for different data, which makes the system immune to the outliers. Field test data was collected to evaluate the proposed algorithm. The comparison results indicate that the proposed algorithm can effectively provide position corrections for standalone INS during the 300 s GPS outage, which outperforms the traditional LS-SVM method. Historical information is also involved to better represent the vehicle dynamics.

  19. Turbine lubricating oil: New filtration advances save time and money

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bushar, T.

    1996-11-01

    This article describes benefits of filtration advances which include fewer forced outages, faster startups and reduced bearing wear. The importance of clean lubricating oil for turbines has been recognized for a long time, and almost all generating plants use some type of filtration system. Many older technologies and systems cannot remove enough of the contaminants to meet the needs of today`s turbines and operating conditions. Newer filtration technologies, such as multiphase filtration systems incorporating pressure coalescence filters to remove water, can reduce contaminants to levels that will help prevent unscheduled or forced outages, allow faster startups after an ongoing outage,more » and reduce wear of bearings and other components. Such preventive measures are more important than ever because of today`s increased competition and emphasis on cost control.« less

  20. The Klamath Falls, Oregon, earthquakes on September 20, 1993

    USGS Publications Warehouse

    Brantley, S.R.

    1993-01-01

    The mainshocks caused light moderate damage at Klamath Falls, a town of about 18,000 residents located only about 20 km east of the epicentral area. Damage included toppled chimneys, cracked masonry, and fallen parapets. Power outages occurred after the strongest shocks. In addition, strong shaking broke water mains, and landslides temporarily blocked highways. the earthquakes also caused two fatalities. A rockfall crushed an automobile, killing a motorist, and an elderly lady had a heart attack. the low population density in the epicentral area- less than five people per sq km- kept the toatl dollar loss to about 7.5 million dollars. 

  1. NASA Launches NOAA Weather Satellite to Improve Forecasts

    NASA Image and Video Library

    2017-11-18

    Early on the morning of Saturday, Nov. 18, NASA successfully launched for the National Oceanic and Atmospheric Administration (NOAA) the first in a series of four advanced polar-orbiting satellites, equipped with next-generation technology and designed to improve the accuracy of U.S. weather forecasts out to seven days. The Joint Polar Satellite System-1 (JPSS-1) lifted off on a United Launch Alliance Delta II rocket from Vandenberg Air Force Base on California’s central coast. JPSS-1 data will improve weather forecasting and help agencies involved with post-storm recovery by visualizing storm damage and the geographic extent of power outages.

  2. Innovation on Energy Power Technology (22)Challenge to Development of Expert System stored Knowledge of Expert Power Network Operators

    NASA Astrophysics Data System (ADS)

    Sakaguchi, Hideharu

    Do you remember an expert system? I think there are various impressions about the system. For example, some might say “It reminds me of old days”. On the other hand, some might say “It was really troublesome”. About 25 years ago, from late 1980s to the middle of 1990s, when the Showa era was about to change into the Heisei Era, artificial intelligence boomed. Research and development for an expert system which was equipped with expertise and worked as smart as expert, was advanced in various fields. Our company also picked up the system as the new system which covered weak point of conventional computer technology. We started research and development in 1984, and installed an expert system in a SCADA system, which started operating in March 1990 in the Fukuoka Integrated Control Center. In this essay, as an electric power engineer who involved in development at that time, I introduce the situation and travail story about developing an expert system which support restorative actions from the outage and overload condition of power networks.

  3. Islanding the power grid on the transmission level: less connections for more security

    PubMed Central

    Mureddu, Mario; Caldarelli, Guido; Damiano, Alfonso; Scala, Antonio; Meyer-Ortmanns, Hildegard

    2016-01-01

    Islanding is known as a management procedure of the power system that is implemented at the distribution level to preserve sensible loads from outages and to guarantee the continuity in electricity supply, when a high amount of distributed generation occurs. In this paper we study islanding on the level of the transmission grid and shall show that it is a suitable measure to enhance energy security and grid resilience. We consider the German and Italian transmission grids. We remove links either randomly to mimic random failure events, or according to a topological characteristic, their so-called betweenness centrality, to mimic an intentional attack and test whether the resulting fragments are self-sustainable. We test this option via the tool of optimized DC power flow equations. When transmission lines are removed according to their betweenness centrality, the resulting islands have a higher chance of being dynamically self-sustainable than for a random removal. Less connections may even increase the grid’s stability. These facts should be taken into account in the design of future power grids. PMID:27713509

  4. Bonneville, Power Administration Timing System

    NASA Technical Reports Server (NTRS)

    Martin, Kenneth E.

    1996-01-01

    Time is an integral part of the Bonneville Power Administration's (BPA) operational systems. Generation and power transfers are planned in advance. Utilities coordinate with each other by making these adjustments on a timed schedule. Price varies with demand, so billing is based on time. Outages for maintenance are scheduled to assure they do not interrupt reliable power delivery. Disturbance records are aligned with recorded timetags for analysis and comparison with related information. Advanced applications like traveling wave fault location and real-time phase measurement require continuous timing with high precision. Most of BPA is served by a Central Time System (CTS) at the Dittmer Control Center near Portland, OR. This system keeps time locally and supplies time to both the control center systems and field locations via a microwave signal. It is kept synchronized to national standard time and coordinated with interconnected utilities. It is the official BPA time. Powwer system control and operation is described, followed by a description of BPA timing systems including CTS, the Fault Location Acquisition Reporter, time dissemination, and phasor measurements. References are provided for further reading.

  5. Islanding the power grid on the transmission level: less connections for more security

    NASA Astrophysics Data System (ADS)

    Mureddu, Mario; Caldarelli, Guido; Damiano, Alfonso; Scala, Antonio; Meyer-Ortmanns, Hildegard

    2016-10-01

    Islanding is known as a management procedure of the power system that is implemented at the distribution level to preserve sensible loads from outages and to guarantee the continuity in electricity supply, when a high amount of distributed generation occurs. In this paper we study islanding on the level of the transmission grid and shall show that it is a suitable measure to enhance energy security and grid resilience. We consider the German and Italian transmission grids. We remove links either randomly to mimic random failure events, or according to a topological characteristic, their so-called betweenness centrality, to mimic an intentional attack and test whether the resulting fragments are self-sustainable. We test this option via the tool of optimized DC power flow equations. When transmission lines are removed according to their betweenness centrality, the resulting islands have a higher chance of being dynamically self-sustainable than for a random removal. Less connections may even increase the grid’s stability. These facts should be taken into account in the design of future power grids.

  6. Worldwide OMEGA and Very Low Frequency (VLF) Transmitter Outages, January to December 1980.

    DTIC Science & Technology

    1981-05-01

    WORLDWIDE OMEGA AND VERY LOW FREQUENCY IVLF) TRANSMITTER OUTAGE--ETC, MAY 81 L RZONCA ,’,L.ASSI LED FAA-CT-81-26 FAA-RD- B1 -29 UL7 A-I’ l15FDRL AIO...computer for the time period GBR - Rugby , England (16.00 kHz) January to December 1980. (For the purposes of this report, any downtime NA - Cutler, Maine

  7. Deep Space Optical Link ARQ Performance Analysis

    NASA Technical Reports Server (NTRS)

    Clare, Loren; Miles, Gregory

    2016-01-01

    Substantial advancements have been made toward the use of optical communications for deep space exploration missions, promising a much higher volume of data to be communicated in comparison with present -day Radio Frequency (RF) based systems. One or more ground-based optical terminals are assumed to communicate with the spacecraft. Both short-term and long-term link outages will arise due to weather at the ground station(s), space platform pointing stability, and other effects. To mitigate these outages, an Automatic Repeat Query (ARQ) retransmission method is assumed, together with a reliable back channel for acknowledgement traffic. Specifically, the Licklider Transmission Protocol (LTP) is used, which is a component of the Disruption-Tolerant Networking (DTN) protocol suite that is well suited for high bandwidth-delay product links subject to disruptions. We provide an analysis of envisioned deep space mission scenarios and quantify buffering, latency and throughput performance, using a simulation in which long-term weather effects are modeled with a Gilbert -Elliot Markov chain, short-term outages occur as a Bernoulli process, and scheduled outages arising from geometric visibility or operational constraints are represented. We find that both short- and long-term effects impact throughput, but long-term weather effects dominate buffer sizing and overflow losses as well as latency performance.

  8. Sampled-data-based vibration control for structural systems with finite-time state constraint and sensor outage.

    PubMed

    Weng, Falu; Liu, Mingxin; Mao, Weijie; Ding, Yuanchun; Liu, Feifei

    2018-05-10

    The problem of sampled-data-based vibration control for structural systems with finite-time state constraint and sensor outage is investigated in this paper. The objective of designing controllers is to guarantee the stability and anti-disturbance performance of the closed-loop systems while some sensor outages happen. Firstly, based on matrix transformation, the state-space model of structural systems with sensor outages and uncertainties appearing in the mass, damping and stiffness matrices is established. Secondly, by considering most of those earthquakes or strong winds happen in a very short time, and it is often the peak values make the structures damaged, the finite-time stability analysis method is introduced to constrain the state responses in a given time interval, and the H-infinity stability is adopted in the controller design to make sure that the closed-loop system has a prescribed level of disturbance attenuation performance during the whole control process. Furthermore, all stabilization conditions are expressed in the forms of linear matrix inequalities (LMIs), whose feasibility can be easily checked by using the LMI Toolbox. Finally, numerical examples are given to demonstrate the effectiveness of the proposed theorems. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Outage analysis of relay-assisted underwater wireless optical communication systems

    NASA Astrophysics Data System (ADS)

    Tabeshnezhad, Azadeh; Pourmina, Mohammad Ali

    2017-12-01

    In this paper, we theoretically evaluate the outage probabilities of underwater wireless optical communication (UWOC) systems. Our derivations are general as the channel model under consideration takes into account all of the channel degrading effects, namely absorption, scattering, and turbulence-induced fading. We numerically show that the UWOC systems, due to the severe channel impairments, cannot typically support longer link ranges than 100 m. Therefore, in this paper, in order to increase the transmission reliability and hence extend the viable communication range of UWOC systems, we apply decode-and-forward (DF) relay-assisted communications either in the form of multi-hop transmission, where multiple intermediate relays are serially employed between the source and destination, or parallel relaying in which multiple DF relays are distributed among the source-to-destination path to cooperate in the end-to-end transmission. Our numerical results reveal that multi-hop transmission, owing to the distance-dependency of all of the channel degrading effects, can tremendously improve the end-to-end outage probability and increase the accessible link ranges to hundreds of meter. For example, a dual-hop transmission in a 45 m coastal water link can provide up to 41 dB performance improvement at the outage probability of 10-9.

  10. Average BER and outage probability of the ground-to-train OWC link in turbulence with rain

    NASA Astrophysics Data System (ADS)

    Zhang, Yixin; Yang, Yanqiu; Hu, Beibei; Yu, Lin; Hu, Zheng-Da

    2017-09-01

    The bit-error rate (BER) and outage probability of optical wireless communication (OWC) link for the ground-to-train of the curved track in turbulence with rain is evaluated. Considering the re-modulation effects of raining fluctuation on optical signal modulated by turbulence, we set up the models of average BER and outage probability in the present of pointing errors, based on the double inverse Gaussian (IG) statistical distribution model. The numerical results indicate that, for the same covered track length, the larger curvature radius increases the outage probability and average BER. The performance of the OWC link in turbulence with rain is limited mainly by the rain rate and pointing errors which are induced by the beam wander and train vibration. The effect of the rain rate on the performance of the link is more severe than the atmospheric turbulence, but the fluctuation owing to the atmospheric turbulence affects the laser beam propagation more greatly than the skewness of the rain distribution. Besides, the turbulence-induced beam wander has a more significant impact on the system in heavier rain. We can choose the size of transmitting and receiving apertures and improve the shockproof performance of the tracks to optimize the communication performance of the system.

  11. Power allocation strategies to minimize energy consumption in wireless body area networks.

    PubMed

    Kailas, Aravind

    2011-01-01

    The wide scale deployment of wireless body area networks (WBANs) hinges on designing energy efficient communication protocols to support the reliable communication as well as to prolong the network lifetime. Cooperative communications, a relatively new idea in wireless communications, offers the benefits of multi-antenna systems, thereby improving the link reliability and boosting energy efficiency. In this short paper, the advantages of resorting to cooperative communications for WBANs in terms of minimized energy consumption are investigated. Adopting an energy model that encompasses energy consumptions in the transmitter and receiver circuits, and transmitting energy per bit, it is seen that cooperative transmission can improve energy efficiency of the wireless network. In particular, the problem of optimal power allocation is studied with the constraint of targeted outage probability. Two strategies of power allocation are considered: power allocation with and without posture state information. Using analysis and simulation-based results, two key points are demonstrated: (i) allocating power to the on-body sensors making use of the posture information can reduce the total energy consumption of the WBAN; and (ii) when the channel condition is good, it is better to recruit less relays for cooperation to enhance energy efficiency.

  12. A real time study on condition monitoring of distribution transformer using thermal imager

    NASA Astrophysics Data System (ADS)

    Mariprasath, T.; Kirubakaran, V.

    2018-05-01

    The transformer is one of the critical apparatus in the power system. At any cost, a few minutes of outages harshly influence the power system. Hence, prevention-based maintenance technique is very essential. The continuous conditioning and monitoring technology significantly increases the life span of the transformer, as well as reduces the maintenance cost. Hence, conditioning and monitoring of transformer's temperature are very essential. In this paper, a critical review has been made on various conditioning and monitoring techniques. Furthermore, a new method, hot spot indication technique, is discussed. Also, transformer's operating condition is monitored by using thermal imager. From the thermal analysis, it is inferred that major hotspot locations are appearing at connection lead out; also, the bushing of the transformer is the very hottest spot in transformer, so monitoring the level of oil is essential. Alongside, real time power quality analysis has been carried out using the power analyzer. It shows that industrial drives are injecting current harmonics to the distribution network, which causes the power quality problem on the grid. Moreover, the current harmonic limit has exceeded the IEEE standard limit. Hence, the adequate harmonics suppression technique is need an hour.

  13. Splice loss requirements in multi-mode fiber mode-division-multiplex transmission links.

    PubMed

    Warm, Stefan; Petermann, Klaus

    2013-01-14

    We investigate numerically the influence of fiber splices and fiber connectors to the statistics of mode dependent loss (MDL) and multiple-input multiple-output (MIMO) outage capacity in mode multiplexed multi-mode fiber links. Our results indicate required splice losses much lower than currently feasible to achieve a reasonable outage capacity in long-haul transmission systems. Splice losses as low as 0.03dB may effectively lead to an outage of MIMO channels after only a few hundred kilometers transmission length. In a first approximation, the relative capacity solely depends on the accumulated splice loss and should be less than ≈ 2dB to ensure a relative capacity of 90%. We also show that discrete mode permutation (mixing) within the transmission line may effectively increase the maximum transmission distance by a factor of 5 for conventional splice losses.

  14. A cascading failure analysis tool for post processing TRANSCARE simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    This is a MATLAB-based tool to post process simulation results in the EPRI software TRANSCARE, for massive cascading failure analysis following severe disturbances. There are a few key modules available in this tool, including: 1. automatically creating a contingency list to run TRANSCARE simulations, including substation outages above a certain kV threshold, N-k (1, 2 or 3) generator outages and branche outages; 2. read in and analyze a CKO file of PCG definition, an initiating event list, and a CDN file; 3. post process all the simulation results saved in a CDN file and perform critical event corridor analysis; 4.more » provide a summary of TRANSCARE simulations; 5. Identify the most frequently occurring event corridors in the system; and 6. Rank the contingencies using a user defined security index to quantify consequences in terms of total load loss, total number of cascades, etc.« less

  15. Outage management and health physics issue, 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2009-05-15

    The focus of the May-June issue is on outage management and health physics. Major articles include the following: Planning and scheduling to minimize refueling outage, by Pat McKenna, AmerenUE; Prioritizing safety, quality and schedule, by Tom Sharkey, Dominion; Benchmarking to high standards, by Margie Jepson, Energy Nuclear; Benchmarking against U.S. standards, by Magnox North, United Kingdom; Enabling suppliers for new build activity, by Marcus Harrington, GE Hitachi Nuclear Energy; Identifying, cultivating and qualifying suppliers, by Thomas E. Silva, AREVA NP; Creating new U.S. jobs, by Francois Martineau, Areva NP. Industry innovation articles include: MSL Acoustic source load reduction, by Amirmore » Shahkarami, Exelon Nuclear; Dual Methodology NDE of CRDM nozzles, by Michael Stark, Dominion Nuclear; and Electronic circuit board testing, by James Amundsen, FirstEnergy Nuclear Operating Company. The plant profile article is titled The future is now, by Julia Milstead, Progress Energy Service Company, LLC.« less

  16. Interleaved Training and Training-Based Transmission Design for Hybrid Massive Antenna Downlink

    NASA Astrophysics Data System (ADS)

    Zhang, Cheng; Jing, Yindi; Huang, Yongming; Yang, Luxi

    2018-06-01

    In this paper, we study the beam-based training design jointly with the transmission design for hybrid massive antenna single-user (SU) and multiple-user (MU) systems where outage probability is adopted as the performance measure. For SU systems, we propose an interleaved training design to concatenate the feedback and training procedures, thus making the training length adaptive to the channel realization. Exact analytical expressions are derived for the average training length and the outage probability of the proposed interleaved training. For MU systems, we propose a joint design for the beam-based interleaved training, beam assignment, and MU data transmissions. Two solutions for the beam assignment are provided with different complexity-performance tradeoff. Analytical results and simulations show that for both SU and MU systems, the proposed joint training and transmission designs achieve the same outage performance as the traditional full-training scheme but with significant saving in the training overhead.

  17. Assessment of Energy Storage Alternatives in the Puget Sound Energy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balducci, Patrick J.; Jin, Chunlian; Wu, Di

    2013-12-01

    As part of an ongoing study co-funded by the Bonneville Power Administration, under its Technology Innovation Grant Program, and the U.S. Department of Energy, the Pacific Northwest National Laboratory (PNNL) has developed an approach and modeling tool for assessing the net benefits of using energy storage located close to the customer in the distribution grid to manage demand. PNNL in collaboration with PSE and Primus Power has evaluated the net benefits of placing a zinc bromide battery system at two locations in the PSE system (Baker River / Rockport and Bainbridge Island). Energy storage can provide a number of benefitsmore » to the utility through the increased flexibility it provides to the grid system. Applications evaluated in the assessment include capacity value, balancing services, arbitrage, distribution deferral and outage mitigation. This report outlines the methodology developed for this study and Phase I results.« less

  18. Business interruption impacts of a terrorist attack on the electric power system of Los Angeles: customer resilience to a total blackout.

    PubMed

    Rose, Adam; Oladosu, Gbadebo; Liao, Shu-Yi

    2007-06-01

    Regional economies are highly dependent on electricity, thus making their power supply systems attractive terrorist targets. We estimate the largest category of economic losses from electricity outages-business interruption-in the context of a total blackout of electricity in Los Angeles. We advance the state of the art in the estimation of the two factors that strongly influence the losses: indirect effects and resilience. The results indicate that indirect effects in the context of general equilibrium analysis are moderate in size. The stronger factor, and one that pushes in the opposite direction, is resilience. Our analysis indicates that electricity customers have the ability to mute the potential shock to their business operations by as much as 86%. Moreover, market resilience lowers the losses, in part through the dampening of general equilibrium effects.

  19. An Adaptive Coordinated Control for an Offshore Wind Farm Connected VSC Based Multi-Terminal DC Transmission System

    NASA Astrophysics Data System (ADS)

    Kumar, M. Ajay; Srikanth, N. V.

    2015-01-01

    The voltage source converter (VSC) based multiterminal high voltage direct current (MTDC) transmission system is an interesting technical option to integrate offshore wind farms with the onshore grid due to its unique performance characteristics and reduced power loss via extruded DC cables. In order to enhance the reliability and stability of the MTDC system, an adaptive neuro fuzzy inference system (ANFIS) based coordinated control design has been addressed in this paper. A four terminal VSC-MTDC system which consists of an offshore wind farm and oil platform is implemented in MATLAB/ SimPowerSystems software. The proposed model is tested under different fault scenarios along with the converter outage and simulation results show that the novel coordinated control design has great dynamic stabilities and also the VSC-MTDC system can supply AC voltage of good quality to offshore loads during the disturbances.

  20. Observing power blackouts from space - A disaster related study

    NASA Astrophysics Data System (ADS)

    Aubrecht, C.; Elvidge, C. D.; Ziskin, D.; Baugh, K. E.; Tuttle, B.; Erwin, E.; Kerle, N.

    2009-04-01

    In case of emergency disaster managers worldwide require immediate information on affected areas and estimations of the number of affected people. Natural disasters such as earthquakes, hurricanes, tornados, wind and ice storms often involve failures in the electrical power generation system and grid. Near real time identification of power blackouts gives a first impression of the area affected by the event (Elvidge et al. 2007), which can subsequently be linked to population estimations. Power blackouts disrupt societal activities and compound the difficulties associated with search and rescue, clean up, and the provision of food and other supplies following a disastrous event. Locations and spatial extents of power blackouts are key considerations in planning and execution of the primary disaster missions of emergency management organizations. To date only one satellite data source has been used successfully for the detection of power blackouts. Operated by NOAA's National Geophysical Data Center (NGDC) the U.S. Air Force Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS) offers a unique capability to observe lights present at the Earth's surface at night. Including a pair of visible and thermal spectral bands and originally designed to detect moonlit clouds, this sensor enables mapping of lights from cities and towns, gas flares and offshore platforms, fires, and heavily lit fishing boats. The low light imaging of the OLS is accomplished using a photomultiplier tube (PMT) which intensifies the visible band signal at night. With 14 orbits collected per day and a 3.000 km swath width, each OLS is capable of collecting a complete set of images of the Earth every 24 hours. NGDC runs the long-term archive for OLS data with the digital version extending back to 1992. OLS data is received by NGDC in near real time (1-2 hours from acquisition) and subscription based services for the near real time data are provided for users all over the world. Elvidge et al. (1998) first demonstrated that under certain conditions a detection of power outages is possible using OLS data. A standard procedure for visual detection of power outages has been developed. The procedure is based on identifying locations where consistently observed lighting is missing or reduced following a disaster event. Visible and thermal spectral bands of the event-related OLS data are compared to a recent cloud-free composite of nighttime lights by producing a color (RGB) composite image. For the cloud-free nighttime lights composite serving as reference information both monthly and annual composites can be used, depending on the respective availability and suitability of OLS data. The RGB color composite uses the reference lights as red (R), the current visible band as green (G) and the current thermal band as blue (B). The thermal band is typically inverted to make clouds appear bright. As clouds are typically colder than the surface of the Earth, in the thermal band higher values are observed on cloud-free areas, which thus appear brighter in standard visualization modes. The resulting color composite is visually interpreted to identify power outages, which show up as red lights on a dark (cloud-free) background. Red color stands for high values in the reference data (red band of the RGB composite) compared to low values in the event data (green and blue bands of the RGB composite), thus showing the disaster-related absence or reduction of lighting. Heavy cloud cover also obscures lights, resulting in red lights on a blue background. Yellow color in the RGB composite indicates areas where the lights are on, i.e. both red and green band (reference composite and visible band of the event image) feature high values with no cloud cover present (low values in the blue band). Under ideal conditions the presented procedure detects individual cities and towns where power has been lost or has been reduced. Conditions reducing or eliminating the capability of detecting power blackouts in OLS data have been identified (e.g. sunlight, heavy cloud cover and bright moonlight). Furthermore, the change detection procedure only works when power blackouts happen or still persist at night at the time of an OLS overpass. In some cases (e.g. Hurricane Katrina) it has been possible to track the gradual recovery of power by repeating the procedure on nights following a disaster event. In this paper several examples of successful power blackout detection following natural disasters including hurricanes (e.g. Isabel 2003 and Wilma 2005 in the USA) and earthquakes (e.g. Gujarat Earthquake 2001 in India) will be presented, whereas overlaid hurricane paths and earthquake epicenters serve as landmarks and indicate locations around the potential highest impact. Disaster impact assessment and post-disaster research is strongly related to impacts on population, related infrastructure and activities (Kerle et al. 2005, Zhang and Kerle 2008). In particular in the case of emergency management and response humans are the main actors and first-pass assessment of affected population and locations of affected areas are essential. Space-based power blackout detection, as described above, has the potential to delineate the spatial extent of the disaster impact. Overlaying the respective OLS data with regional population data such as LandScan (Dobson et al. 2000) or Gridded Population of the World (CIESIN and CIAT 2005) allows estimating a potential number of affected people. Without a doubt such estimates comprise a considerable number of uncertainties. However, the capability of providing the information in near-real time as offered by using DMSP-OLS makes the presented approach very valuable for emergency and disaster managers worldwide. REFERENCES Center for International Earth Science Information Network CIESIN at Columbia University, and Centro Internacional de Agricultura Tropical CIAT (2005). Gridded Population of the World Version 3 (GPWv3). Palisades, NY: Socioeconomic Data and Applications Center (SEDAC), Columbia University. Available at http://sedac.ciesin.columbia.edu/gpw (last visited 01/08/2009). Dobson, J.E., E.A. Bright, P.R. Coleman, R.C. Durfee, and B.A. Worley (2000) LandScan: A Global Population Database for Estimating Populations at Risk. Photogrammetric Engineering & Remote Sensing 66(7), 849-857. Elvidge, C.D., K.E. Baugh, V.R. Hobson, E.A. Kihn, and H.W. Kroehl (1998) Detection of Fires and Power Outages Using DMSP-OLS Data. In: Lunetta, R.S., and Elvidge, C.D. (eds.) Remote Sensing Change Detection: Environmental Monitoring Methods and Applications. Ann Arbor Press, pp 123-135. Elvidge, C.D., C. Aubrecht, K. Baugh, B. Tuttle, and A.T. Howard (2007) Satellite detection of power outages following earthquakes and other events. 3rd International Geohazards Workshop. GEO & IGOS Geohazards. Proceedings. ESA/ESRIN, Frascati (Rome), Italy, November 6-9, 2007. Kerle, N., R. Stekelenburg, F. van den Heuvel, and B.G.H. Gorte (2005) Near - real time post - disaster damage assessment with airborne oblique video data. In: van Oosterom, P.J.M., Zlatanova, S., and Elfriede, M. (eds.) Geo-information for disaster management Gi4DM : Proceedings of the 1st International Symposium on Geo-Information for Disaster Management. Berlin: Springer, pp 337-353. Zhang, Y., and N. Kerle (2008) Satellite remote sensing for near-real time data collection. In: Zlatanova, S., Li, J. (eds.) Geospatial information technology for emergency response. Berlin: Springer, pp 75-102.

  1. Advanced Metering Infrastructure based on Smart Meters

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  2. Development of bubble memory recorder onboard Japan Earth Resources Satellite-1

    NASA Astrophysics Data System (ADS)

    Araki, Tsunehiko; Ishida, Chu; Ochiai, Kiyoshi; Nozue, Tatsuhiro; Tachibana, Kyozo; Yoshida, Kazutoshi

    The Bubble Memory Recorder (BMR) developed for use on the Earth Resources Satellite is described in terms of its design, capabilities, and functions. The specifications of the BMR are given listing memory capacity, functions, and interface types for data, command, and telemetry functions. The BMR has an emergency signal interface to provide contingency recording, and a satellite-separation signal interface can be turned on automatically by signal input. Data are stored in a novolatile memory device so that the memory is retained during power outages. The BMR is characterized by a capability for random access, nonvolatility, and a solid-state design that is useful for space operations since it does not disturb spacecraft attitude.

  3. Response of human populations to large-scale emergencies

    NASA Astrophysics Data System (ADS)

    Bagrow, James; Wang, Dashun; Barabási, Albert-László

    2010-03-01

    Until recently, little quantitative data regarding collective human behavior during dangerous events such as bombings and riots have been available, despite its importance for emergency management, safety and urban planning. Understanding how populations react to danger is critical for prediction, detection and intervention strategies. Using a large telecommunications dataset, we study for the first time the spatiotemporal, social and demographic response properties of people during several disasters, including a bombing, a city-wide power outage, and an earthquake. Call activity rapidly increases after an event and we find that, when faced with a truly life-threatening emergency, information rapidly propagates through a population's social network. Other events, such as sports games, do not exhibit this propagation.

  4. Decontamination, decommissioning, and vendor advertorial issue, 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2006-07-15

    The focus of the July-August issue is on Decontamination, decommissioning, and vendor advertorials. Major articles/reports in this issue include: NPP Krsko revised decommissioning program, by Vladimir Lokner and Ivica Levanat, APO d.o.o., Croatia, and Nadja Zeleznik and Irena Mele, ARAO, Slovenia; Supporting the renaissance, by Marilyn C. Kray, Exelon Nuclear; Outage world an engineer's delight, by Tom Chrisopher, Areva, NP Inc.; Optimizing refueling outages with R and D, by Ross Marcoot, GE Energy; and, A successful project, by Jim Lash, FirstEnergy.

  5. Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, Yuri V.; Huang, Zhenyu; Etingov, Pavel V.

    2010-09-01

    The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and windmore » forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. In this report, a new methodology to predict the uncertainty ranges for the required balancing capacity, ramping capability and ramp duration is presented. Uncertainties created by system load forecast errors, wind and solar forecast errors, generation forced outages are taken into account. The uncertainty ranges are evaluated for different confidence levels of having the actual generation requirements within the corresponding limits. The methodology helps to identify system balancing reserve requirement based on a desired system performance levels, identify system “breaking points”, where the generation system becomes unable to follow the generation requirement curve with the user-specified probability level, and determine the time remaining to these potential events. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (California ISO) real life data have shown the effectiveness of the proposed approach. A tool developed based on the new methodology described in this report will be integrated with the California ISO systems. Contractual work is currently in place to integrate the tool with the AREVA EMS system.« less

  6. Power mobility with collision avoidance for older adults: user, caregiver, and prescriber perspectives.

    PubMed

    Wang, Rosalie H; Korotchenko, Alexandra; Hurd Clarke, Laura; Mortenson, W Ben; Mihailidis, Alex

    2013-01-01

    Collision avoidance technology has the capacity to facilitate safer mobility among older power mobility users with physical, sensory, and cognitive impairments, thus enabling independence for more users. Little is known about consumers' perceptions of collision avoidance. This article draws on interviews (29 users, 5 caregivers, and 10 prescribers) to examine views on design and utilization of this technology. Data analysis identified three themes: "useful situations or contexts," "technology design issues and real-life application," and "appropriateness of collision avoidance technology for a variety of users." Findings support ongoing development of collision avoidance for older adult users. The majority of participants supported the technology and felt that it might benefit current users and users with visual impairments, but might be unsuitable for people with significant cognitive impairments. Some participants voiced concerns regarding the risk for injury with power mobility use and some identified situations where collision avoidance might be beneficial (driving backward, avoiding dynamic obstacles, negotiating outdoor barriers, and learning power mobility use). Design issues include the need for context awareness, reliability, and user interface specifications. User desire to maintain driving autonomy supports development of collaboratively controlled systems. This research lays the groundwork for future development by illustrating consumer requirements for this technology.

  7. Human reliability and plant operating efficiency: Are 12-hour work schedules cause for concern

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, T.L.

    1992-01-01

    Since the introduction of 12-h shifts to the US nuclear power industry only 8 yr ago, compressed workweek schedules have proliferated among operations departments at a phenomenal rate. Many plants that continue to use 8-h shifts during normal operations routinely change to scheduled 12-h shifts during refueling or maintenance outages. The most critical issue in the use of extended work shifts is whether alertness, physical stamina, or mental performance are compromised to the point of reducing safety or efficiency of nuclear power plant operation. Laboratory and field research sponsored by the National Institute of Occupational Safety and Health suggests thatmore » alertness, measured by self-ratings, and mental performance, measured by computer-based performance tests, are impaired on 12-h shifts compared with 8-h shifts. In contrast to these findings, plant operating efficiency and operator performance have been rated as improved in two field studies conducted in operating nuclear power plants (Fast Flux Test Facility, Washington and Ontario Hydro, Canada). A recent Electric Power Research Institute review of nuclear industry experience with 12-h shifts also suggests an overwhelmingly positive rating of 12-h schedules from both control room operators and management.« less

  8. Using Rapid Improvement Events for Disaster After-Action Reviews: Experience in a Hospital Information Technology Outage and Response.

    PubMed

    Little, Charles M; McStay, Christopher; Oeth, Justin; Koehler, April; Bookman, Kelly

    2018-02-01

    The use of after-action reviews (AARs) following major emergency events, such as a disaster, is common and mandated for hospitals and similar organizations. There is a recurrent challenge of identified problems not being resolved and repeated in subsequent events. A process improvement technique called a rapid improvement event (RIE) was used to conduct an AAR following a complete information technology (IT) outage at a large urban hospital. Using RIE methodology to conduct the AAR allowed for the rapid development and implementation of major process improvements to prepare for future IT downtime events. Thus, process improvement methodology, particularly the RIE, is suited for conducting AARs following disasters and holds promise for improving outcomes in emergency management. Little CM , McStay C , Oeth J , Koehler A , Bookman K . Using rapid improvement events for disaster after-action reviews: experience in a hospital information technology outage and response. Prehosp Disaster Med. 2018;33(1):98-100.

  9. Power Mobility with Collision Avoidance for Older Adults: User, Caregiver and Prescriber Perspectives

    PubMed Central

    Wang, Rosalie H; Korotchenko, Alexandra; Clarke, Laura Hurd; Ben Mortenson, W; Mihailidis, Alex

    2017-01-01

    Collision avoidance technology has the capacity to facilitate safer mobility among older power mobility users with physical, sensory and cognitive impairments, thus enabling independence for more potential users. However, little is known about consumers’ perceptions of collision avoidance. This article draws on interviews with 29 users, five caregivers, and 10 prescribers to examine views on the design and utilization of this technology. Data analysis identified three themes: “useful situations or contexts”, “technology design issues and real life application”, and “appropriateness of collision avoidance technology for a variety of users”. Findings support the ongoing development of collision avoidance for older adult users. The majority of participants were supportive of the technology, and felt that it might benefit current power mobility users and users with visual impairments, but might be unsuitable for people with significant cognitive impairments. Some participants voiced concerns regarding the risk for injury with power mobility use and some identified situations where collision avoidance might be beneficial (driving backwards, avoiding dynamic obstacles, negotiating outdoor barriers, and learning power mobility use). Design issues include the need for context awareness, reliability, and user interface specifications. Furthermore, user desire to maintain driving autonomy indicates the need to develop collaboratively-controlled systems. This research lays the groundwork for future development by identifying and illustrating consumer needs for this technology. PMID:24458968

  10. The 2012 derecho: emergency medical services and hospital response.

    PubMed

    Kearns, Randy D; Wigal, Mark S; Fernandez, Antonio; Tucker, March A; Zuidgeest, Ginger R; Mills, Michael R; Cairns, Bruce A; Cairns, Charles B

    2014-10-01

    During the early afternoon of June 29, 2012, a line of destructive thunderstorms producing straight line winds known as a derecho developed near Chicago (Illinois, USA). The storm moved southeast with wind speeds recorded from 100 to 160 kilometers per hour (kph, 60 to 100 miles per hour [mph]). The storm swept across much of West Virginia (USA) later that evening. Power outage was substantial as an estimated 1,300,000 West Virginians (more than half) were without power in the aftermath of the storm and approximately 600,000 citizens were still without power a week later. This was one of the worst storms to strike this area and occurred as residents were enduring a prolonged heat wave. The wind damage left much of the community without electricity and the crippling effect compromised or destroyed critical infrastructure including communications, air conditioning, refrigeration, and water and sewer pumps. This report describes utilization of Emergency Medical Services (EMS) and hospital resources in West Virginia in response to the storm. Also reported is a review of the weather phenomena and the findings and discussion of the disaster and implications.

  11. Operating experience with the southwire 30-meter high-temperature superconducting power cable

    NASA Astrophysics Data System (ADS)

    Stovall, J. P.; Lue, J. W.; Demko, J. A.; Fisher, P. W.; Gouge, M. J.; Hawsey, R. A.; Armstrong, J. W.; Hughey, R. L.; Lindsay, D. T.; Roden, M. L.; Sinha, U. K.; Tolbert, J. C.

    2002-05-01

    Southwire Company is operating a high-temperature superconducting (HTS) cable system at its corporate headquarters. The 30-m long, 3-phase cable system is powering three Southwire manufacturing plants and is rated at 12.4-kV, 1250-A, 60-Hz. Cooling is provided by a pressurized liquid nitrogen system operating at 70-80 K. The cables were energized on January 5, 2000 for on-line testing and operation and in April 2000 were placed into extended service. As of June 1, 2001, the HTS cables have provided 100% of the customer load for 8000 hours. The cryogenic system has been in continuous operation since November 1999. The HTS cable system has not been the cause of any power outages to the average 20 MW industrial load served by the cable. The cable has been exposed to short-circuit currents caused by load-side faults without damage. Based upon field measurements described herein, the cable critical current-a key performance parameter-remains the same and has not been affected by the hours of real-world operation, further proving the viability of this promising technology.

  12. Low-cost data acquisition systems for photovoltaic system monitoring and usage statistics

    NASA Astrophysics Data System (ADS)

    Fanourakis, S.; Wang, K.; McCarthy, P.; Jiao, L.

    2017-11-01

    This paper presents the design of a low-cost data acquisition system for monitoring a photovoltaic system’s electrical quantities, battery temperatures, and state of charge of the battery. The electrical quantities are the voltages and currents of the solar panels, the battery, and the system loads. The system uses an Atmega328p microcontroller to acquire data from the photovoltaic system’s charge controller. It also records individual load information using current sensing resistors along with a voltage amplification circuit and an analog to digital converter. The system is used in conjunction with a wall power data acquisition system for the recording of regional power outages. Both data acquisition systems record data in micro SD cards. The data has been successfully acquired from both systems and has been used to monitor the status of the PV system and the local power grid. As more data is gathered it can be used for the maintenance and improvement of the photovoltaic system through analysis of the photovoltaic system’s parameters and usage statistics.

  13. Hydrogen Fuel Cell Performance as Telecommunications Backup Power in the United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, Jennifer; Saur, Genevieve; Sprik, Sam

    2015-03-01

    Working in collaboration with the U.S. Department of Energy (DOE) and industry project partners, the National Renewable Energy Laboratory (NREL) acts as the central data repository for the data collected from real-world operation of fuel cell backup power systems. With American Recovery and Reinvestment Act of 2009 (ARRA) co-funding awarded through DOE's Fuel Cell Technologies Office, more than 1,300 fuel cell units were deployed over a three-plus-year period in stationary, material handling equipment, auxiliary power, and backup power applications. This surpassed a Fuel Cell Technologies Office ARRA objective to spur commercialization of an early market technology by installing 1,000 fuelmore » cell units across several different applications, including backup power. By December 2013, 852 backup power units out of 1,330 fuel cell units deployed were providing backup service, mainly for telecommunications towers. For 136 of the fuel cell backup units, project participants provided detailed operational data to the National Fuel Cell Technology Evaluation Center for analysis by NREL's technology validation team. NREL analyzed operational data collected from these government co-funded demonstration projects to characterize key fuel cell backup power performance metrics, including reliability and operation trends, and to highlight the business case for using fuel cells in these early market applications. NREL's analyses include these critical metrics, along with deployment, U.S. grid outage statistics, and infrastructure operation.« less

  14. Assessment and Application of the ROSE Code for Reactor Outage Thermal-Hydraulic and Safety Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Thomas K.S.; Ko, F.-K.; Dai, L.-C

    The currently available tools, such as RELAP5, RETRAN, and others, cannot easily and correctly perform the task of analyzing the system behavior during plant outages. Therefore, a medium-sized program aiming at reactor outage simulation and evaluation, such as midloop operation (MLO) with loss of residual heat removal (RHR), has been developed. Important thermal-hydraulic processes involved during MLO with loss of RHR can be properly simulated by the newly developed reactor outage simulation and evaluation (ROSE) code. The two-region approach with a modified two-fluid model has been adopted to be the theoretical basis of the ROSE code.To verify the analytical modelmore » in the first step, posttest calculations against the integral midloop experiments with loss of RHR have been performed. The excellent simulation capacity of the ROSE code against the Institute of Nuclear Energy Research Integral System Test Facility test data is demonstrated. To further mature the ROSE code in simulating a full-sized pressurized water reactor, assessment against the WGOTHIC code and the Maanshan momentary-loss-of-RHR event has been undertaken. The successfully assessed ROSE code is then applied to evaluate the abnormal operation procedure (AOP) with loss of RHR during MLO (AOP 537.4) for the Maanshan plant. The ROSE code also has been successfully transplanted into the Maanshan training simulator to support operator training. How the simulator was upgraded by the ROSE code for MLO will be presented in the future.« less

  15. Big Data Analytics for Disaster Preparedness and Response of Mobile Communication Infrastructure during Natural Hazards

    NASA Astrophysics Data System (ADS)

    Zhong, L.; Takano, K.; Ji, Y.; Yamada, S.

    2015-12-01

    The disruption of telecommunications is one of the most critical disasters during natural hazards. As the rapid expanding of mobile communications, the mobile communication infrastructure plays a very fundamental role in the disaster response and recovery activities. For this reason, its disruption will lead to loss of life and property, due to information delays and errors. Therefore, disaster preparedness and response of mobile communication infrastructure itself is quite important. In many cases of experienced disasters, the disruption of mobile communication networks is usually caused by the network congestion and afterward long-term power outage. In order to reduce this disruption, the knowledge of communication demands during disasters is necessary. And big data analytics will provide a very promising way to predict the communication demands by analyzing the big amount of operational data of mobile users in a large-scale mobile network. Under the US-Japan collaborative project on 'Big Data and Disaster Research (BDD)' supported by the Japan Science and Technology Agency (JST) and National Science Foundation (NSF), we are going to investigate the application of big data techniques in the disaster preparedness and response of mobile communication infrastructure. Specifically, in this research, we have considered to exploit the big amount of operational information of mobile users for predicting the communications needs in different time and locations. By incorporating with other data such as shake distribution of an estimated major earthquake and the power outage map, we are able to provide the prediction information of stranded people who are difficult to confirm safety or ask for help due to network disruption. In addition, this result could further facilitate the network operators to assess the vulnerability of their infrastructure and make suitable decision for the disaster preparedness and response. In this presentation, we are going to introduce the results we obtained based on the big data analytics of mobile user statistical information and discuss the implications of these results.

  16. On-Line Thermal Barrier Coating Monitoring for Real-Time Failure Protection and Life Maximization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2004-10-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Westinghouse Power Corporation proposes a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization'', to develop, build and install the first generation of an on-line TBC monitoring system for use on land -based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability availability maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCsmore » have been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can therefore accelerate the degradation of substrate components materials and eventually lead to a premature failure of critical component and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Westinghouse Power Corporation has teamed with Indigo Systems; a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization.« less

  17. A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

    DOE PAGES

    Wang, Zeyu; Wang, Jianhui; Chen, Chen

    2016-12-07

    Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraintmore » is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.« less

  18. A Three-Phase Microgrid Restoration Model Considering Unbalanced Operation of Distributed Generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zeyu; Wang, Jianhui; Chen, Chen

    Recent severe outages highlight the urgency of improving grid resiliency in the U.S. Microgrid formation schemes are proposed to restore critical loads after outages occur. Most distribution networks have unbalanced configurations that are not represented in sufficient detail by single-phase models. This study provides a microgrid formation plan that adopts a three-phase network model to represent unbalanced distribution networks. The problem formulation has a quadratic objective function with mixed-integer linear constraints. The three-phase network model enables us to examine the three-phase power outputs of distributed generators (DGs), preventing unbalanced operation that might trip DGs. Because the DG unbalanced operation constraintmore » is non-convex, an iterative process is presented that checks whether the unbalanced operation limits for DGs are satisfied after each iteration of optimization. We also develop a relatively conservative linear approximation on the unbalanced operation constraint to handle larger networks. Compared with the iterative solution process, the conservative linear approximation is able to accelerate the solution process at the cost of sacrificing optimality to a limited extent. Simulation in the IEEE 34 node and IEEE 123 test feeders indicate that the proposed method yields more practical microgrid formations results. In addition, this paper explores the coordinated operation of DGs and energy storage (ES) installations. The unbalanced three-phase outputs of ESs combined with the relatively balanced outputs of DGs could supply unbalanced loads. In conclusion, the case study also validates the DG-ES coordination.« less

  19. Honey Bee Colonies Remote Monitoring System.

    PubMed

    Gil-Lebrero, Sergio; Quiles-Latorre, Francisco Javier; Ortiz-López, Manuel; Sánchez-Ruiz, Víctor; Gámiz-López, Victoria; Luna-Rodríguez, Juan Jesús

    2016-12-29

    Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD). The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees' work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee) based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive-monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time.

  20. Honey Bee Colonies Remote Monitoring System

    PubMed Central

    Gil-Lebrero, Sergio; Quiles-Latorre, Francisco Javier; Ortiz-López, Manuel; Sánchez-Ruiz, Víctor; Gámiz-López, Victoria; Luna-Rodríguez, Juan Jesús

    2016-01-01

    Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD). The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee) based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time. PMID:28036061

  1. Dependable Networks as a Paradigm for Network Innovation

    NASA Astrophysics Data System (ADS)

    Miki, Tetsuya

    In past, dependable networks meant minimizing network outages or the impact of the outages. However, over the decade, major network services have shifted from telephone and data transmission to Internet and to mobile communication, where higher layer services with a variety of contents are provided. Reviewing these backgrounds of network development, the importance of the dependability of higher layer network services are pointed out. Then, the main aspects to realize the dependability are given for lower, middle and higher layer network services. In addition, some particular issues for dependable networks are described.

  2. Evaluating the CO 2 emissions reduction potential and cost of power sector re-dispatch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinberg, Daniel C.; Bielen, David A.; Townsend, Aaron

    Prior studies of the U.S. electricity sector have recognized the potential to reduce carbon dioxide (CO2) emissions by substituting generation from coal-fired units with generation from under-utilized and lower-emitting natural gas-fired units; in fact, this type of 're-dispatch' was invoked as one of the three building blocks used to set the emissions targets under the Environmental Protection Agency's Clean Power Plan. Despite the existence of surplus natural gas capacity in the U.S., power system operational constraints not often considered in power sector policy analyses, such as transmission congestion, generator ramping constraints, minimum generation constraints, planned and unplanned generator outages, andmore » ancillary service requirements, could limit the potential and increase the cost of coal-to-gas re-dispatch. Using a highly detailed power system unit commitment and dispatch model, we estimate the maximum potential for re-dispatch in the Eastern Interconnection, which accounts for the majority of coal capacity and generation in the U.S. Under our reference assumptions, we find that maximizing coal-to-gas re-dispatch yields emissions reductions of 230 million metric tons (Mt), or 13% of power sector emissions in the Eastern Interconnection, with a corresponding average abatement cost of $15-$44 per metric ton of CO2, depending on the assumed supply elasticity of natural gas.« less

  3. The Role of Channel Distribution Information for Interference Management and Network Performance Enhancement

    DTIC Science & Technology

    2010-11-03

    U,V wTp s.t. Γl ≥ γl,l = 1, . . . , L (2) For a fixed set of channel matrices Hli’s, this problem can be solved and will give a set of power...outage. The main optimization problem using CDI can then be formulated: min p≥0,U,V wTp s.t. Pr(Γl ≤ γl) ≤ αl, l = 1, . . . , L (3) In this formulation...can be written as min p≥0,U,V wTp s.t. 1− e− γl 2 σ2Nl cllpl ∏ i 6=l ( 1 + γl clipi cllpl )−1 ≤ αl, l = 1, . . . , L (11) To get the constraints in (11

  4. Investigating the feasibility of Visualising Complex Space Weather Data in a CAVE

    NASA Astrophysics Data System (ADS)

    Loughlin, S.; Habash Krause, L.

    2013-12-01

    The purpose of this study was to investigate the feasibility of visualising complex space weather data in a Cave Automatic Virtual Environment (CAVE). Space weather is increasingly causing disruptions on Earth, such as power outages and disrupting communication to satellites. We wanted to display this space weather data within the CAVE since the data from instruments, models and simulations are typically too complex to understand on their own, especially when they are of 7 dimensions. To accomplish this, I created a VTK to NetCDF converter. NetCDF is a science data format, which stores array oriented scientific data. The format is maintained by the University Corporation for Atmospheric Research, and is used extensively by the atmospheric and space communities.

  5. Three essays on energy and environmental economics: Empirical, applied, and theoretical

    NASA Astrophysics Data System (ADS)

    Karney, Daniel Houghton

    Energy and environmental economics are closely related fields as nearly all forms of energy production generate pollution and thus nearly all forms of environmental policy affect energy production and consumption. The three essays in this dissertation are related by their common themes of energy and environmental economics, but they differ in their methodologies. The first chapter is an empirical exercise that looks that the relationship between electricity price deregulation and maintenance outages at nuclear power plants. The second chapter is an applied theory paper that investigates environmental regulation in a multiple pollutants setting. The third chapter develops a new methodology regarding the construction of analytical general equilibrium models that can be used to study topics in energy and environmental economics.

  6. Extended Operation of Stirling Convertors at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Oriti, Salvatore

    2011-01-01

    Glenn Research Center (GRC) is supporting life and reliability database for free-piston Stirilng conversion via extended convertor operation Ongoing convertor operation: 18 convertors (4 TDCs from Infinia, 14 ASCs from Sunpower). 350,000 total convertor hours of operation. 218,000 on Infinia units and 132,000 on Sunpower units. Demonstrating steady convertor performance requires precise maintenance of operating conditions. Sources of disruption : Investigative tests: Varying operating frequency, hot-end temp, cold-end temp. Hot end control method: Constant heat input mode requires more user-adjustment than constant temperature mode. Long-term transients in hot end insulation were observed. Support facility: Open-bath circulator fluid concentration drifting. Nuisance shutdowns (instrumentation failure, EMI, power outages). Ambient temperature fluctuations due to room HVAC.

  7. Capacity and reliability analyses with applications to power quality

    NASA Astrophysics Data System (ADS)

    Azam, Mohammad; Tu, Fang; Shlapak, Yuri; Kirubarajan, Thiagalingam; Pattipati, Krishna R.; Karanam, Rajaiah

    2001-07-01

    The deregulation of energy markets, the ongoing advances in communication networks, the proliferation of intelligent metering and protective power devices, and the standardization of software/hardware interfaces are creating a dramatic shift in the way facilities acquire and utilize information about their power usage. The currently available power management systems gather a vast amount of information in the form of power usage, voltages, currents, and their time-dependent waveforms from a variety of devices (for example, circuit breakers, transformers, energy and power quality meters, protective relays, programmable logic controllers, motor control centers). What is lacking is an information processing and decision support infrastructure to harness this voluminous information into usable operational and management knowledge to handle the health of their equipment and power quality, minimize downtime and outages, and to optimize operations to improve productivity. This paper considers the problem of evaluating the capacity and reliability analyses of power systems with very high availability requirements (e.g., systems providing energy to data centers and communication networks with desired availability of up to 0.9999999). The real-time capacity and margin analysis helps operators to plan for additional loads and to schedule repair/replacement activities. The reliability analysis, based on computationally efficient sum of disjoint products, enables analysts to decide the optimum levels of redundancy, aids operators in prioritizing the maintenance options for a given budget and monitoring the system for capacity margin. The resulting analytical and software tool is demonstrated on a sample data center.

  8. Ofeq-2 orbit, attitude, and flight evaluation

    NASA Astrophysics Data System (ADS)

    Grumer, Michael; Komem, Joseph; Kronenfeld, Joseph; Kubitski, Ophir; Lorber, Vitaly; Shyldkrot, Haim

    1992-02-01

    The most significant events and phenomena that occurred during the Ofeq-2 flight are evaluated in this work. Particular attention is paid to the physical and technological factors which affected its orbital lifetime. Comparison of Ofeq-2 telemetry results with prelaunch estimations and with Ofeq-1 flight data are presented. The satellite's orbit and mission characteristics are defined and the principal systems of Ofeq-2 are described. Topics addressed include the interaction between the spinner's attitude with respect to the sun and consequent electric power generation. The coning angle development history, the role of the solar data evaluation, and the factors influencing drag are also analyzed. All of these affected the Ofeq-2 power outage-recovery event. The orbit determination and the coning angle evolution estimation methods are discussed in some detail. A brief report on radiation effects on computer RAM (random access memory) is also given. An integrative systems engineering approach summary of the telemetry data reconstruction and analysis concludes the paper.

  9. Exploring the Relationship of Organizational Culture and Implicit Leadership Theory to Performance Differences in the Nuclear and Fossil Energy Industry

    NASA Astrophysics Data System (ADS)

    Cravey, Kristopher J.

    Notable performance differences exist between nuclear and fossil power generation plants in areas such as safety, outage duration efficiency, and capacity factor. This study explored the relationship of organizational culture and implicit leadership theory to these performance differences. A mixed methods approach consisting of quantitative instruments, namely the Organizational Culture Assessment Instrument and the GLOBE Leadership Scales, and qualitative interviews were used in this study. Subjects were operations middle managers in a U.S. energy company that serves nuclear or fossil power plants. Results from the quantitative instruments revealed no differences between nuclear and fossil groups in regards to organizational culture types and implicit leadership theories. However, the qualitative results did reveal divergence between the two groups in regards to what is valued in the organization and how that drives behaviors and decision making. These organizational phenomenological differences seem to explain why performance differences exist between nuclear and fossil plants because, ultimately, they affect how the organization functions.

  10. AGR-3/4 Final Data Qualification Report for ATR Cycles 151A through 155B-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pham, Binh T.

    2015-03-01

    This report provides the qualification status of experimental data for the entire Advanced Gas Reactor 3/4 (AGR 3/4) fuel irradiation. AGR-3/4 is the third in a series of planned irradiation experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for the AGR Fuel Development and Qualification Program, which supports development of the advanced reactor technology under the INL ART Technology Development Office (TDO). The main objective of AGR-3/4 irradiation is to provide a known source of fission products for subsequent transport through compact matrix and structural graphite materials due to the presence of designed-to-fail fuel particles.more » Full power irradiation of the AGR 3/4 test began on December 14, 2011 (ATR Cycle 151A), and was completed on April 12, 2014 (end of ATR Cycle 155B) after 369.1 effective full power days of irradiation. The AGR-3/4 test was in the reactor core for eight of the ten ATR cycles between 151A and 155B. During the unplanned outage cycle, 153A, the experiment was removed from the ATR northeast flux trap (NEFT) location and stored in the ATR canal. This was to prevent overheating of fuel compacts due to higher than normal ATR power during the subsequent Powered Axial Locator Mechanism cycle, 153B. The AGR 3/4 test was inserted back into the ATR NEFT location during the outage of ATR Cycle 154A on April 26, 2013. Therefore, the AGR-3/4 irradiation data received during these 2 cycles (153A and 153B) are irrelevant and their qualification status isnot included in this report. Additionally, during ATR Cycle 152A the ATR core ran at low power for a short enough duration that the irradiation data are not used for physics and thermal calculations. However, the qualification status of irradiation data for this cycle is still covered in this report. As a result, this report includes data from 8 ATR Cycles: 151A, 151B, 152A, 152B, 154A, 154B, 155A, and 155B, as recorded in the Nuclear Data Management and Analysis System (NDMAS). The AGR 3/4 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates, pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates, release to birth rate ratios [R/Bs], and particle failure counts) for each of the twelve capsules in the AGR 3/4 experiment. During Outage Cycle 155A, fourteen flow meters were installed downstream from fourteen FPMS monitors to measure flows from the monitors; qualification status of these data are also included in the report. The final data qualification status for these data streams is determined by a Data Review Committee (DRC) composed of AGR technical leads, Sitewide Quality Assurance (QA), and NDMAS analysts. For ATR Cycles 151A through 154B, the DRC convened on February 12, 2014, reviewed the data acquisition process, and considered whether the data met the requirements for data collection as specified in QA approved INL ART TDO data collection plans. The DRC also examined the results of NDMAS data testing and statistical analyses, and confirmed the qualification status of the data as given in this report. The qualification status of AGR-3/4 irradiation data during the first six cycles were previously reported in INL/EXT-14-31186 document. This report presents data qualification status for the entire AGR-3/4 irradiation.« less

  11. Global investigations of the satellite-based Fugro OmniSTAR HP service

    NASA Astrophysics Data System (ADS)

    Pflugmacher, Andreas; Heister, Hansbert; Heunecke, Otto

    2009-12-01

    OmniSTAR is one of the world's leading suppliers of satellite-based augmentation services for onshore and offshore GNSS applications. OmniSTAR currently offers three services: VBS, HP and XP. OmniSTAR VBS is the code-based service, suitable for sub-metre positioning accuracy. The HP and XP services provide sub-decimetre accuracy, with the HP service based on a precise differential methodology and the XP service uses precise absolute positioning. The sub-decimetre HP and XP services both have distinctive convergence behaviour, and the positioning task is essentially a time-dependent process during which the accuracy of the estimated coordinates continuously improves over time. To validate the capabilities of the OmniSTAR services, and in particular the HP (High Performance) service, globally distributed measurement campaigns were performed. The results of these investigations confirm that the HP service satisfies its high accuracy specification, but only after a sufficient initialisation phase. Two kinds of disturbances can handicap HP operation: lack of GNSS observations and outages of the augmentation signal. The most serious kind of disturbance is the former. Within a few seconds the achieved convergence level is completely lost. Outages in the reception of augmentation data merely affect the relevant period of the outage - the accuracy during the outage is degraded. Only longer interruptions lead to a loss of the HP solution. When HP convergence is lost, the HP process has to be re-initialized. If there are known points (so-called “seed points”) available, a shortened “kick-start”-initialization is possible. With the aid of seed points it only takes a few minutes to restore convergence.

  12. Designing PURPA (Public Utilities Regulatory Policies Act) power purchase auctions: Theory and practice. [Buys from cogenerators and small power generators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Public Utilities Regulatory Act (PURPA) requires there to be procedures for electric utilities to buy electric power from qualifying cogenerators and small power producers (QFs) at rates up to ''avoided cost''. This has led to price-posting procedures at prices calculated as the utility's marginal cost. Unexpectedly large sales at these prices and slow adjustment to falling energy cost are partially responsible for payments to QFs in excess of the utility's true avoided cost. Using competitive bidding instead of posted prices has been proposed as a way to avoid this outcome. This report reviews bidding theory and explores four issuesmore » that arise in designing auction systems for the purchase of power from QFs under PURPA.« less

  13. Invited Article: Visualisation of extreme value events in optical communications

    NASA Astrophysics Data System (ADS)

    Derevyanko, Stanislav; Redyuk, Alexey; Vergeles, Sergey; Turitsyn, Sergei

    2018-06-01

    Fluctuations of a temporal signal propagating along long-haul transoceanic scale fiber links can be visualised in the spatio-temporal domain drawing visual analogy with ocean waves. Substantial overlapping of information symbols or use of multi-frequency signals leads to strong statistical deviations of local peak power from an average signal power level. We consider long-haul optical communication systems from this unusual angle, treating them as physical systems with a huge number of random statistical events, including extreme value fluctuations that potentially might affect the quality of data transmission. We apply the well-established concepts of adaptive wavefront shaping used in imaging through turbid medium to detect the detrimental phase modulated sequences in optical communications that can cause extreme power outages (rare optical waves of ultra-high amplitude) during propagation down the ultra-long fiber line. We illustrate the concept by a theoretical analysis of rare events of high-intensity fluctuations—optical freak waves, taking as an example an increasingly popular optical frequency division multiplexing data format where the problem of high peak to average power ratio is the most acute. We also show how such short living extreme value spikes in the optical data streams are affected by nonlinearity and demonstrate the negative impact of such events on the system performance.

  14. Intelligent Prediction of Fan Rotation Stall in Power Plants Based on Pressure Sensor Data Measured In-Situ

    PubMed Central

    Xu, Xiaogang; Wang, Songling; Liu, Jinlian; Liu, Xinyu

    2014-01-01

    Blower and exhaust fans consume over 30% of electricity in a thermal power plant, and faults of these fans due to rotation stalls are one of the most frequent reasons for power plant outage failures. To accurately predict the occurrence of fan rotation stalls, we propose a support vector regression machine (SVRM) model that predicts the fan internal pressures during operation, leaving ample time for rotation stall detection. We train the SVRM model using experimental data samples, and perform pressure data prediction using the trained SVRM model. To prove the feasibility of using the SVRM model for rotation stall prediction, we further process the predicted pressure data via wavelet-transform-based stall detection. By comparison of the detection results from the predicted and measured pressure data, we demonstrate that the SVRM model can accurately predict the fan pressure and guarantee reliable stall detection with a time advance of up to 0.0625 s. This superior pressure data prediction capability leaves significant time for effective control and prevention of fan rotation stall faults. This model has great potential for use in intelligent fan systems with stall prevention capability, which will ensure safe operation and improve the energy efficiency of power plants. PMID:24854057

  15. IDMA-Based MAC Protocol for Satellite Networks with Consideration on Channel Quality

    PubMed Central

    2014-01-01

    In order to overcome the shortcomings of existing medium access control (MAC) protocols based on TDMA or CDMA in satellite networks, interleave division multiple access (IDMA) technique is introduced into satellite communication networks. Therefore, a novel wide-band IDMA MAC protocol based on channel quality is proposed in this paper, consisting of a dynamic power allocation algorithm, a rate adaptation algorithm, and a call admission control (CAC) scheme. Firstly, the power allocation algorithm combining the technique of IDMA SINR-evolution and channel quality prediction is developed to guarantee high power efficiency even in terrible channel conditions. Secondly, the effective rate adaptation algorithm, based on accurate channel information per timeslot and by the means of rate degradation, can be realized. What is more, based on channel quality prediction, the CAC scheme, combining the new power allocation algorithm, rate scheduling, and buffering strategies together, is proposed for the emerging IDMA systems, which can support a variety of traffic types, and offering quality of service (QoS) requirements corresponding to different priority levels. Simulation results show that the new wide-band IDMA MAC protocol can make accurate estimation of available resource considering the effect of multiuser detection (MUD) and QoS requirements of multimedia traffic, leading to low outage probability as well as high overall system throughput. PMID:25126592

  16. Application of SAW method for multiple-criteria comparative analysis of the reliability of heat supply organizations

    NASA Astrophysics Data System (ADS)

    Akhmetova, I. G.; Chichirova, N. D.

    2016-12-01

    Heat supply is the most energy-consuming sector of the economy. Approximately 30% of all used primary fuel-and-energy resources is spent on municipal heat-supply needs. One of the key indicators of activity of heat-supply organizations is the reliability of an energy facility. The reliability index of a heat supply organization is of interest to potential investors for assessing risks when investing in projects. The reliability indices established by the federal legislation are actually reduced to a single numerical factor, which depends on the number of heat-supply outages in connection with disturbances in operation of heat networks and the volume of their resource recovery in the calculation year. This factor is rather subjective and may change in a wide range during several years. A technique is proposed for evaluating the reliability of heat-supply organizations with the use of the simple additive weighting (SAW) method. The technique for integrated-index determination satisfies the following conditions: the reliability level of the evaluated heat-supply system is represented maximum fully and objectively; the information used for the reliability-index evaluation is easily available (is located on the Internet in accordance with demands of data-disclosure standards). For reliability estimation of heat-supply organizations, the following indicators were selected: the wear of equipment of thermal energy sources, the wear of heat networks, the number of outages of supply of thermal energy (heat carrier due to technological disturbances on heat networks per 1 km of heat networks), the number of outages of supply of thermal energy (heat carrier due to technologic disturbances on thermal energy sources per 1 Gcal/h of installed power), the share of expenditures in the cost of thermal energy aimed at recovery of the resource (renewal of fixed assets), coefficient of renewal of fixed assets, and a coefficient of fixed asset retirement. A versatile program is developed and the analysis of heat-supply organizations is performed by the example of the Republic of Tatarstan. The assessment system is based on construction of comparative ratings of heat-supply organizations. A rating is the assessment of reliability of the organization, is characterized by a numerical value, and makes it possible to compare organizations engaged in the same kind of activity between each other.

  17. A piezoelectric brace for passive suppression of structural vibration and energy harvesting

    NASA Astrophysics Data System (ADS)

    Yang, Chuang-Sheng Walter; Lai, Yong-An; Kim, Jin-Yeon

    2017-08-01

    Power outage after an earthquake would cause an additional chaos to the existing aftermath, greatly aggravating the situation if the outage lasts for an extended period. This research aims at developing an innovative piezoelectric brace, which provides both passive energy-dissipating and energy-harvesting capabilities—a passive suppression of structural vibrations and conversion of vibration energy into reusable electricity. The piezoelectric brace has compression modules that exert compressive loads on the piezoelectric material regardless if the brace is in compression or in tension. The compression module consists of a piezoelectric stack and rubber pads. The rubber pads are used to limit the maximum strain in the piezoelectric material below the allowable operational strain. The electro-mechanical equations of motion are derived for a 1-story and a 3-story frame model with the piezoelectric braces. To evaluate the structural behavior and the energy harvesting performance, numerical simulations are executed for the two model buildings (in downtown Los Angeles) that are equipped with the piezoelectric braces. The effects of design parameters including the geometry of the piezoelectric stack and rubber pads and the electric resistance in the electro-mechanical conversion circuit on the performance are investigated. The numerical results indicate that the piezoelectric braces passively dissipate energy through inclined oval-shaped hysteretic loops. The harvested energy is up to approximately 40% of the input energy. The structural displacements are significantly reduced, as compared to the original frames without the piezoelectric braces. Finally, a design procedure for a frame with the proposed passive piezoelectric braces is also presented.

  18. Radar tracking with an interacting multiple model and probabilistic data association filter for civil aviation applications.

    PubMed

    Jan, Shau-Shiun; Kao, Yu-Chun

    2013-05-17

    The current trend of the civil aviation technology is to modernize the legacy air traffic control (ATC) system that is mainly supported by many ground based navigation aids to be the new air traffic management (ATM) system that is enabled by global positioning system (GPS) technology. Due to the low receiving power of GPS signal, it is a major concern to aviation authorities that the operation of the ATM system might experience service interruption when the GPS signal is jammed by either intentional or unintentional radio-frequency interference. To maintain the normal operation of the ATM system during the period of GPS outage, the use of the current radar system is proposed in this paper. However, the tracking performance of the current radar system could not meet the required performance of the ATM system, and an enhanced tracking algorithm, the interacting multiple model and probabilistic data association filter (IMMPDAF), is therefore developed to support the navigation and surveillance services of the ATM system. The conventional radar tracking algorithm, the nearest neighbor Kalman filter (NNKF), is used as the baseline to evaluate the proposed radar tracking algorithm, and the real flight data is used to validate the IMMPDAF algorithm. As shown in the results, the proposed IMMPDAF algorithm could enhance the tracking performance of the current aviation radar system and meets the required performance of the new ATM system. Thus, the current radar system with the IMMPDAF algorithm could be used as an alternative system to continue aviation navigation and surveillance services of the ATM system during GPS outage periods.

  19. Radar Tracking with an Interacting Multiple Model and Probabilistic Data Association Filter for Civil Aviation Applications

    PubMed Central

    Jan, Shau-Shiun; Kao, Yu-Chun

    2013-01-01

    The current trend of the civil aviation technology is to modernize the legacy air traffic control (ATC) system that is mainly supported by many ground based navigation aids to be the new air traffic management (ATM) system that is enabled by global positioning system (GPS) technology. Due to the low receiving power of GPS signal, it is a major concern to aviation authorities that the operation of the ATM system might experience service interruption when the GPS signal is jammed by either intentional or unintentional radio-frequency interference. To maintain the normal operation of the ATM system during the period of GPS outage, the use of the current radar system is proposed in this paper. However, the tracking performance of the current radar system could not meet the required performance of the ATM system, and an enhanced tracking algorithm, the interacting multiple model and probabilistic data association filter (IMMPDAF), is therefore developed to support the navigation and surveillance services of the ATM system. The conventional radar tracking algorithm, the nearest neighbor Kalman filter (NNKF), is used as the baseline to evaluate the proposed radar tracking algorithm, and the real flight data is used to validate the IMMPDAF algorithm. As shown in the results, the proposed IMMPDAF algorithm could enhance the tracking performance of the current aviation radar system and meets the required performance of the new ATM system. Thus, the current radar system with the IMMPDAF algorithm could be used as an alternative system to continue aviation navigation and surveillance services of the ATM system during GPS outage periods. PMID:23686142

  20. On-Line Thermal Barrier Coating Monitoring for Real-Time Failure Protection and Life Maximization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2005-04-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Westinghouse Power Corporation proposes a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization'', to develop, build and install the first generation of an on-line TBC monitoring system for use on land-based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability availability maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCs havemore » been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can therefore accelerate the degradation of substrate components materials and eventually lead to a premature failure of critical component and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Westinghouse Power Corporation has teamed with Indigo Systems, a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization in the field of infrared non-destructive examination (NDE), to complete the program.« less

  1. ON-LINE THERMAL BARRIER COATING MONITORING FOR REAL-TIME FAILURE PROTECTION AND LIFE MAXIMIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2003-10-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Westinghouse Power Corporation proposes a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization,'' to develop, build and install the first generation of an on-line TBC monitoring system for use on land-based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability, availability, and maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCsmore » have been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can, therefore, accelerate the degradation of substrate component materials and eventually lead to a premature failure of critical components and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Westinghouse Power Corporation has teamed with Indigo Systems, a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization in the field of infrared non-destructive examination (NDE), to complete the program.« less

  2. ON-LINE THERMAL BARRIER COATING MONITORING FOR REAL-TIME FAILURE PROTECTION AND LIFE MAXIMIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2003-07-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Westinghouse Power Corporation proposes a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization,'' to develop, build and install the first generation of an on-line TBC monitoring system for use on land-based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability, availability, and maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCsmore » have been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can, therefore, accelerate the degradation of substrate component materials and eventually lead to a premature failure of critical components and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Westinghouse Power Corporation has teamed with Indigo Systems, a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization in the field of infrared non-destructive examination (NDE), to complete the program.« less

  3. On-Line Thermal Barrier Coating Monitoring for Real-Time Failure Protection and Life Maximization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis H. LeMieux

    2005-10-01

    Under the sponsorship of the U. S. Department of Energy's National Energy Laboratory, Siemens Power Generation, Inc proposed a four year program titled, ''On-Line Thermal Barrier Coating (TBC) Monitor for Real-Time Failure Protection and Life Maximization'', to develop, build and install the first generation of an on-line TBC monitoring system for use on land-based advanced gas turbines (AGT). Federal deregulation in electric power generation has accelerated power plant owner's demand for improved reliability availability maintainability (RAM) of the land-based advanced gas turbines. As a result, firing temperatures have been increased substantially in the advanced turbine engines, and the TBCs havemore » been developed for maximum protection and life of all critical engine components operating at these higher temperatures. Losing TBC protection can therefore accelerate the degradation of substrate components materials and eventually lead to a premature failure of critical component and costly unscheduled power outages. This program seeks to substantially improve the operating life of high cost gas turbine components using TBC; thereby, lowering the cost of maintenance leading to lower cost of electricity. Siemens Power Generation, Inc. has teamed with Indigo Systems, a supplier of state-of-the-art infrared camera systems, and Wayne State University, a leading research organization in the field of infrared non-destructive examination (NDE), to complete the program.« less

  4. Decision support for mitigating the risk of tree induced transmission line failure in utility rights-of-way.

    PubMed

    Poulos, H M; Camp, A E

    2010-02-01

    Vegetation management is a critical component of rights-of-way (ROW) maintenance for preventing electrical outages and safety hazards resulting from tree contact with conductors during storms. Northeast Utility's (NU) transmission lines are a critical element of the nation's power grid; NU is therefore under scrutiny from federal agencies charged with protecting the electrical transmission infrastructure of the United States. We developed a decision support system to focus right-of-way maintenance and minimize the potential for a tree fall episode that disables transmission capacity across the state of Connecticut. We used field data on tree characteristics to develop a system for identifying hazard trees (HTs) in the field using limited equipment to manage Connecticut power line ROW. Results from this study indicated that the tree height-to-diameter ratio, total tree height, and live crown ratio were the key characteristics that differentiated potential risk trees (danger trees) from trees with a high probability of tree fall (HTs). Products from this research can be transferred to adaptive right-of-way management, and the methods we used have great potential for future application to other regions of the United States and elsewhere where tree failure can disrupt electrical power.

  5. The Origin of the "Seasons" in Space Weather

    NASA Astrophysics Data System (ADS)

    Dikpati, Mausumi; Cally, Paul S.; McIntosh, Scott W.; Heifetz, Eyal

    2017-11-01

    Powerful `space weather' events caused by solar activity pose serious risks to human health, safety, economic activity and national security. Spikes in deaths due to heart attacks, strokes and other diseases occurred during prolonged power outages. Currently it is hard to prepare for and mitigate the impact of space weather because it is impossible to forecast the solar eruptions that can cause these terrestrial events until they are seen on the Sun. However, as recently reported in Nature, eruptive events like coronal mass ejections and solar flares, are organized into quasi-periodic "seasons", which include enhanced bursts of eruptions for several months, followed by quiet periods. We explored the dynamics of sunspot-producing magnetic fields and discovered for the first time that bursty and quiet seasons, manifested in surface magnetic structures, can be caused by quasi-periodic energy-exchange among magnetic fields, Rossby waves and differential rotation of the solar interior shear-layer (called tachocline). Our results for the first time provide a quantitative physical mechanism for forecasting the strength and duration of bursty seasons several months in advance, which can greatly enhance our ability to warn humans about dangerous solar bursts and prevent damage to satellites and power stations from space weather events.

  6. The Origin of the "Seasons" in Space Weather.

    PubMed

    Dikpati, Mausumi; Cally, Paul S; McIntosh, Scott W; Heifetz, Eyal

    2017-11-07

    Powerful 'space weather' events caused by solar activity pose serious risks to human health, safety, economic activity and national security. Spikes in deaths due to heart attacks, strokes and other diseases occurred during prolonged power outages. Currently it is hard to prepare for and mitigate the impact of space weather because it is impossible to forecast the solar eruptions that can cause these terrestrial events until they are seen on the Sun. However, as recently reported in Nature, eruptive events like coronal mass ejections and solar flares, are organized into quasi-periodic "seasons", which include enhanced bursts of eruptions for several months, followed by quiet periods. We explored the dynamics of sunspot-producing magnetic fields and discovered for the first time that bursty and quiet seasons, manifested in surface magnetic structures, can be caused by quasi-periodic energy-exchange among magnetic fields, Rossby waves and differential rotation of the solar interior shear-layer (called tachocline). Our results for the first time provide a quantitative physical mechanism for forecasting the strength and duration of bursty seasons several months in advance, which can greatly enhance our ability to warn humans about dangerous solar bursts and prevent damage to satellites and power stations from space weather events.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuruganti, Phani Teja

    The smart grid is a combined process of revitalizing the traditional power grid applications and introducing new applications to improve the efficiency of power generation, transmission and distribution. This can be achieved by leveraging advanced communication and networking technologies. Therefore the selection of the appropriate communication technology for different smart grid applications has been debated a lot in the recent past. After comparing different possible technologies, a recent research study has arrived at a conclusion that the 3G cellular technology is the right choice for distribution side smart grid applications like smart metering, advanced distribution automation and demand response managementmore » system. In this paper, we argue that the current 3G/4G cellular technologies are not an appropriate choice for smart grid distribution applications and propose a Hybrid Spread Spectrum (HSS) based Advanced Metering Infrastructure (AMI) as one of the alternatives to 3G/4G technologies. We present a preliminary PHY and MAC layer design of a HSS based AMI network and evaluate their performance using matlab and NS2 simulations. Also, we propose a time hierarchical scheme that can significantly reduce the volume of random access traffic generated during blackouts and the delay in power outage reporting.« less

  8. Characteristics of health IT outage and suggested risk management strategies: an analysis of historical incident reports in China.

    PubMed

    Lei, Jianbo; Guan, Pengcheng; Gao, Kaihua; Lu, Xueqin; Chen, Yunan; Li, Yuefeng; Meng, Qun; Zhang, Jiajie; Sittig, Dean F; Zheng, Kai

    2014-02-01

    The healthcare industry has become increasingly dependent on using information technology (IT) to manage its daily operations. Unexpected downtime of health IT systems could therefore wreak havoc and result in catastrophic consequences. Little is known, however, regarding the nature of failures of health IT. To analyze historical health IT outage incidents as a means to better understand health IT vulnerabilities and inform more effective prevention and emergency response strategies. We studied news articles and incident reports publicly available on the internet describing health IT outage events that occurred in China. The data were qualitatively analyzed using a deductive grounded theory approach based on a synthesized IT risk model developed in the domain of information systems. A total of 116 distinct health IT incidents were identified. A majority of them (69.8%) occurred in the morning; over 50% caused disruptions to the patient registration and payment collection functions of the affected healthcare facilities. The outpatient practices in tertiary hospitals seem to be particularly vulnerable to IT failures. Software defects and overcapacity issues, followed by malfunctioning hardware, were among the principal causes. Unexpected health IT downtime occurs more and more often with the widespread adoption of electronic systems in healthcare. Risk identification and risk assessments are essential steps to developing preventive measures. Equally important is institutionalization of contingency plans as our data show that not all failures of health IT can be predicted and thus effectively prevented. The results of this study also suggest significant future work is needed to systematize the reporting of health IT outage incidents in order to promote transparency and accountability. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Evaluation on the impact of IMU grades on BDS + GPS PPP/INS tightly coupled integration

    NASA Astrophysics Data System (ADS)

    Gao, Zhouzheng; Ge, Maorong; Shen, Wenbin; Li, You; Chen, Qijin; Zhang, Hongping; Niu, Xiaoji

    2017-09-01

    The unexpected observing environments in dynamic applications may lead to partial and/or complete satellite signal outages frequently, which can definitely impact on the positioning performance of the Precise Point Positioning (PPP) in terms of decreasing available satellite numbers, breaking the continuity of observations, and degrading PPP's positioning accuracy. Generally, both the Inertial Navigation System (INS) and the multi-constellation Global Navigation Satellite System (GNSS) can be used to enhance the performance of PPP. This paper introduces the mathematical models of the multi-GNSS PPP/INS Tightly Coupled Integration (TCI), and investigates its performance from several aspects. Specifically, it covers (1) the use of the BDS/GPS PPP, PPP/INS, and their combination; (2) three positioning modes including PPP, PPP/INS TCI, and PPP/INS Loosely Coupled Integration (LCI); (3) the use of four various INS systems named navigation grade, tactical grade, auto grade, and Micro-Electro-Mechanical-Sensors (MEMS) one; (4) three PPP observation scenarios including PPP available, partially available, and fully outage. According to the statistics results, (1) the positioning performance of the PPP/INS (either TCI or LCI) mode is insignificantly depended on the grade of inertial sensor, when there are enough available satellites; (2) after the complete GNSS outages, the TCI mode expresses both higher convergence speed and more accurate positioning solutions than the LCI mode. Furthermore, in the TCI mode, using a higher grade inertial sensor is beneficial for the PPP convergence; (3) under the partial GNSS outage situations, the PPP/INS TCI mode position divergence speed is also restrained significantly; and (4) the attitude determination accuracy of the PPP/INS integration is highly correlated with the grade of inertial sensor.

  10. Power quality improvement by using STATCOM control scheme in wind energy generation interface to grid

    NASA Astrophysics Data System (ADS)

    Kirmani, Sheeraz; Kumar, Brijesh

    2018-01-01

    “Electric Power Quality (EPQ) is a term that refers to maintaining the near sinusoidal waveform of power distribution bus voltages and currents at rated magnitude and frequency”. Today customers are more aware of the seriousness that the power quality possesses, this prompt the utilities to assure good quality of power to their customer. The power quality is basically customer centric. Increased focus of utilities toward maintaining reliable power supply by employing power quality improvement tools has reduced the power outages and black out considerably. Good power quality is the characteristic of reliable power supply. Low power factor, harmonic pollution, load imbalance, fast voltage variations are some common parameters which are used to define the power quality. If the power quality issues are not checked i.e. the parameters that define power quality doesn't fall within the predefined standards than it will lead into high electricity bill, high running cost in industries, malfunctioning of equipments, challenges in connecting renewable. Capacitor banks, FACTS devices, harmonic filters, SVC’s (static voltage compensators), STATCOM (Static-Compensator) are the solutions to achieve the power quality. The performance of Wind turbine generators is affected by poor quality power, at the same time these wind power generating plant affects the power quality negatively. This paper presents the STATCOM-BESS (battery energy storage system) system and studies its impact on the power quality in a system which consists of wind turbine generator, non linear load, hysteresis controller for controlling the operation of STATCOM and grid. The model is simulated in the MATLAB/Simulink. This scheme mitigates the power quality issues, improves voltage profile and also reduces harmonic distortion of the waveforms. BESS level out the imbalances caused in real power due to intermittent nature of wind power available due to varying wind speeds.

  11. High-Temperature Graphitization Failure of Primary Superheater Tube

    NASA Astrophysics Data System (ADS)

    Ghosh, D.; Ray, S.; Roy, H.; Mandal, N.; Shukla, A. K.

    2015-12-01

    Failure of boiler tubes is the main cause of unit outages of the plant, which further affects the reliability, availability and safety of the unit. So failure analysis of boiler tubes is absolutely essential to predict the root cause of the failure and the steps are taken for future remedial action to prevent the failure in near future. This paper investigates the probable cause/causes of failure of the primary superheater tube in a thermal power plant boiler. Visual inspection, dimensional measurement, chemical analysis, metallographic examination and hardness measurement are conducted as the part of the investigative studies. Apart from these tests, mechanical testing and fractographic analysis are also conducted as supplements. Finally, it is concluded that the superheater tube is failed due to graphitization for prolonged exposure of the tube at higher temperature.

  12. A performance analysis in AF full duplex relay selection network

    NASA Astrophysics Data System (ADS)

    Ngoc, Long Nguyen; Hong, Nhu Nguyen; Loan, Nguyen Thi Phuong; Kieu, Tam Nguyen; Voznak, Miroslav; Zdralek, Jaroslav

    2018-04-01

    This paper studies on the relaying selective matter in amplify-and-forward (AF) cooperation communication with full-duplex (FD) activity. Various relay choice models supposing the present of different instant information are investigated. We examine a maximal relaying choice that optimizes the instant FD channel capacity and asks for global channel state information (CSI) as well as partial CSI learning. To make comparison easy, accurate outage probability clauses and asymptote form of these strategies that give a diversity rank are extracted. From that, we can see clearly that the number of relays, noise factor, the transmittance coefficient as well as the information transfer power had impacted on their performance. Besides, the optimal relay selection (ORS) model can promote than that of the partial relay selection (PRS) model.

  13. FLUIDIC: Metal Air Recharged

    ScienceCinema

    Friesen, Cody

    2018-02-14

    Fluidic, with the help of ARPA-E funding, has developed and deployed the world's first proven high cycle life metal air battery. Metal air technology, often used in smaller scale devices like hearing aids, has the lowest cost per electron of any rechargeable battery storage in existence. Deploying these batteries for grid reliability is competitive with pumped hydro installations while having the advantages of a small footprint. Fluidic's battery technology allows utilities and other end users to store intermittent energy generated from solar and wind, as well as maintain reliable electrical delivery during power outages. The batteries are manufactured in the US and currently deployed to customers in emerging markets for cell tower reliability. As they continue to add customers, they've gained experience and real world data that will soon be leveraged for US grid reliability.

  14. Optimal Dispatch of Unreliable Electric Grid-Connected Diesel Generator-Battery Power Systems

    NASA Astrophysics Data System (ADS)

    Xu, D.; Kang, L.

    2015-06-01

    Diesel generator (DG)-battery power systems are often adopted by telecom operators, especially in semi-urban and rural areas of developing countries. Unreliable electric grids (UEG), which have frequent and lengthy outages, are peculiar to these regions. DG-UEG-battery power system is an important kind of hybrid power system. System dispatch is one of the key factors to hybrid power system integration. In this paper, the system dispatch of a DG-UEG-lead acid battery power system is studied with the UEG of relatively ample electricity in Central African Republic (CAR) and UEG of poor electricity in Congo Republic (CR). The mathematical models of the power system and the UEG are studied for completing the system operation simulation program. The net present cost (NPC) of the power system is the main evaluation index. The state of charge (SOC) set points and battery bank charging current are the optimization variables. For the UEG in CAR, the optimal dispatch solution is SOC start and stop points 0.4 and 0.5 that belong to the Micro-Cycling strategy and charging current 0.1 C. For the UEG in CR, the optimal dispatch solution is of 0.1 and 0.8 that belongs to the Cycle-Charging strategy and 0.1 C. Charging current 0.1 C is suitable for both grid scenarios compared to 0.2 C. It makes the dispatch strategy design easier in commercial practices that there are a few very good candidate dispatch solutions with system NPC values close to that of the optimal solution for both UEG scenarios in CAR and CR.

  15. Interface Control Document for the EMPACT Module that Estimates Electric Power Transmission System Response to EMP-Caused Damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Werley, Kenneth Alan; Mccown, Andrew William

    The EPREP code is designed to evaluate the effects of an Electro-Magnetic Pulse (EMP) on the electric power transmission system. The EPREP code embodies an umbrella framework that allows a user to set up analysis conditions and to examine analysis results. The code links to three major physics/engineering modules. The first module describes the EM wave in space and time. The second module evaluates the damage caused by the wave on specific electric power (EP) transmission system components. The third module evaluates the consequence of the damaged network on its (reduced) ability to provide electric power to meet demand. Thismore » third module is the focus of the present paper. The EMPACT code serves as the third module. The EMPACT name denotes EMP effects on Alternating Current Transmission systems. The EMPACT algorithms compute electric power transmission network flow solutions under severely damaged network conditions. Initial solutions are often characterized by unacceptible network conditions including line overloads and bad voltages. The EMPACT code contains algorithms to adjust optimally network parameters to eliminate network problems while minimizing outages. System adjustments include automatically adjusting control equipment (generator V control, variable transformers, and variable shunts), as well as non-automatic control of generator power settings and minimal load shedding. The goal is to evaluate the minimal loss of customer load under equilibrium (steady-state) conditions during peak demand.« less

  16. Statistical-QoS Guaranteed Energy Efficiency Optimization for Energy Harvesting Wireless Sensor Networks

    PubMed Central

    Cheng, Wenchi; Zhang, Hailin

    2017-01-01

    Energy harvesting, which offers a never-ending energy supply, has emerged as a prominent technology to prolong the lifetime and reduce costs for the battery-powered wireless sensor networks. However, how to improve the energy efficiency while guaranteeing the quality of service (QoS) for energy harvesting based wireless sensor networks is still an open problem. In this paper, we develop statistical delay-bounded QoS-driven power control policies to maximize the effective energy efficiency (EEE), which is defined as the spectrum efficiency under given specified QoS constraints per unit harvested energy, for energy harvesting based wireless sensor networks. For the battery-infinite wireless sensor networks, our developed QoS-driven power control policy converges to the Energy harvesting Water Filling (E-WF) scheme and the Energy harvesting Channel Inversion (E-CI) scheme under the very loose and stringent QoS constraints, respectively. For the battery-finite wireless sensor networks, our developed QoS-driven power control policy becomes the Truncated energy harvesting Water Filling (T-WF) scheme and the Truncated energy harvesting Channel Inversion (T-CI) scheme under the very loose and stringent QoS constraints, respectively. Furthermore, we evaluate the outage probabilities to theoretically analyze the performance of our developed QoS-driven power control policies. The obtained numerical results validate our analysis and show that our developed optimal power control policies can optimize the EEE over energy harvesting based wireless sensor networks. PMID:28832509

  17. Statistical-QoS Guaranteed Energy Efficiency Optimization for Energy Harvesting Wireless Sensor Networks.

    PubMed

    Gao, Ya; Cheng, Wenchi; Zhang, Hailin

    2017-08-23

    Energy harvesting, which offers a never-ending energy supply, has emerged as a prominent technology to prolong the lifetime and reduce costs for the battery-powered wireless sensor networks. However, how to improve the energy efficiency while guaranteeing the quality of service (QoS) for energy harvesting based wireless sensor networks is still an open problem. In this paper, we develop statistical delay-bounded QoS-driven power control policies to maximize the effective energy efficiency (EEE), which is defined as the spectrum efficiency under given specified QoS constraints per unit harvested energy, for energy harvesting based wireless sensor networks. For the battery-infinite wireless sensor networks, our developed QoS-driven power control policy converges to the Energy harvesting Water Filling (E-WF) scheme and the Energy harvesting Channel Inversion (E-CI) scheme under the very loose and stringent QoS constraints, respectively. For the battery-finite wireless sensor networks, our developed QoS-driven power control policy becomes the Truncated energy harvesting Water Filling (T-WF) scheme and the Truncated energy harvesting Channel Inversion (T-CI) scheme under the very loose and stringent QoS constraints, respectively. Furthermore, we evaluate the outage probabilities to theoretically analyze the performance of our developed QoS-driven power control policies. The obtained numerical results validate our analysis and show that our developed optimal power control policies can optimize the EEE over energy harvesting based wireless sensor networks.

  18. Relay Selection for Cooperative Relaying in Wireless Energy Harvesting Networks

    NASA Astrophysics Data System (ADS)

    Zhu, Kaiyan; Wang, Fei; Li, Songsong; Jiang, Fengjiao; Cao, Lijie

    2018-01-01

    Energy harvesting from the surroundings is a promising solution to provide energy supply and extend the life of wireless sensor networks. Recently, energy harvesting has been shown as an attractive solution to prolong the operation of cooperative networks. In this paper, we propose a relay selection scheme to optimize the amplify-and-forward (AF) cooperative transmission in wireless energy harvesting cooperative networks. The harvesting energy and channel conditions are considered to select the optimal relay as cooperative relay to minimize the outage probability of the system. Simulation results show that our proposed relay selection scheme achieves better outage performance than other strategies.

  19. Exploiting Outage and Error Probability of Cooperative Incremental Relaying in Underwater Wireless Sensor Networks

    PubMed Central

    Nasir, Hina; Javaid, Nadeem; Sher, Muhammad; Qasim, Umar; Khan, Zahoor Ali; Alrajeh, Nabil; Niaz, Iftikhar Azim

    2016-01-01

    This paper embeds a bi-fold contribution for Underwater Wireless Sensor Networks (UWSNs); performance analysis of incremental relaying in terms of outage and error probability, and based on the analysis proposition of two new cooperative routing protocols. Subject to the first contribution, a three step procedure is carried out; a system model is presented, the number of available relays are determined, and based on cooperative incremental retransmission methodology, closed-form expressions for outage and error probability are derived. Subject to the second contribution, Adaptive Cooperation in Energy (ACE) efficient depth based routing and Enhanced-ACE (E-ACE) are presented. In the proposed model, feedback mechanism indicates success or failure of data transmission. If direct transmission is successful, there is no need for relaying by cooperative relay nodes. In case of failure, all the available relays retransmit the data one by one till the desired signal quality is achieved at destination. Simulation results show that the ACE and E-ACE significantly improves network performance, i.e., throughput, when compared with other incremental relaying protocols like Cooperative Automatic Repeat reQuest (CARQ). E-ACE and ACE achieve 69% and 63% more throughput respectively as compared to CARQ in hard underwater environment. PMID:27420061

  20. Long-Term Tracking of a Specific Vehicle Using Airborne Optical Camera Systems

    NASA Astrophysics Data System (ADS)

    Kurz, F.; Rosenbaum, D.; Runge, H.; Cerra, D.; Mattyus, G.; Reinartz, P.

    2016-06-01

    In this paper we present two low cost, airborne sensor systems capable of long-term vehicle tracking. Based on the properties of the sensors, a method for automatic real-time, long-term tracking of individual vehicles is presented. This combines the detection and tracking of the vehicle in low frame rate image sequences and applies the lagged Cell Transmission Model (CTM) to handle longer tracking outages occurring in complex traffic situations, e.g. tunnels. The CTM model uses the traffic conditions in the proximities of the target vehicle and estimates its motion to predict the position where it reappears. The method is validated on an airborne image sequence acquired from a helicopter. Several reference vehicles are tracked within a range of 500m in a complex urban traffic situation. An artificial tracking outage of 240m is simulated, which is handled by the CTM. For this, all the vehicles in the close proximity are automatically detected and tracked to estimate the basic density-flow relations of the CTM model. Finally, the real and simulated trajectories of the reference vehicles in the outage are compared showing good correspondence also in congested traffic situations.

  1. Automation of steam generator services at public service electric & gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cruickshank, H.; Wray, J.; Scull, D.

    1995-03-01

    Public Service Electric & Gas takes an aggressive approach to pursuing new exposure reduction techniques. Evaluation of historic outage exposure shows that over the last eight refueling outages, primary steam generator work has averaged sixty-six (66) person-rem, or, approximately tewenty-five percent (25%) of the general outage exposure at Salem Station. This maintenance evolution represents the largest percentage of exposure for any single activity. Because of this, primary steam generator work represents an excellent opportunity for the development of significant exposure reduction techniques. A study of primary steam generator maintenance activities demonstrated that seventy-five percent (75%) of radiation exposure was duemore » to work activities of the primary steam generator platform, and that development of automated methods for performing these activities was worth pursuing. Existing robotics systems were examined and it was found that a new approach would have to be developed. This resulted in a joint research and development project between Westinghouse and Public Service Electric & Gas to develop an automated system of accomplishing the Health Physics functions on the primary steam generator platform. R.O.M.M.R.S. (Remotely Operated Managed Maintenance Robotics System) was the result of this venture.« less

  2. Performance analysis of an IMU-augmented GNSS tracking system on board the MAIUS-1 sounding rocket

    NASA Astrophysics Data System (ADS)

    Braun, Benjamin; Grillenberger, Andreas; Markgraf, Markus

    2018-05-01

    Satellite navigation receivers are adequate tracking sensors for range safety of both orbital launch vehicles and suborbital sounding rockets. Due to high accuracy and its low system complexity, satellite navigation is seen as well-suited supplement or replacement of conventional tracking systems like radar. Having the well-known shortcomings of satellite navigation like deliberate or unintentional interferences in mind, it is proposed to augment the satellite navigation receiver by an inertial measurement unit (IMU) to enhance continuity and availability of localization. The augmented receiver is thus enabled to output at least an inertial position solution in case of signal outages. In a previous study, it was shown by means of simulation using the example of Ariane 5 that the performance of a low-grade microelectromechanical IMU is sufficient to bridge expected outages of some ten seconds, and still meeting the range safety requirements in effect. In this publication, these theoretical findings shall be substantiated by real flight data that were recorded on MAIUS-1, a sounding rocket launched from Esrange, Sweden, in early 2017. The analysis reveals that the chosen representative of a microelectromechanical IMU is suitable to bridge outages of up to thirty seconds.

  3. PURPA 210 avoided cost rates: Economic and implementation issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devine, M.D.; Chartock, M.A.; Gunn, E.M.

    The purpose of Section 210 of the Public Utilities Regulatory Policies Act (PURPA) was to promote the utilization of waste and renewable fuels and cogeneration processes for increasing electric power supplies. It represents a radical change in policy by allowing financially unregulated parties to generate power in ''qualifying facilities'' and by requiring utilities to purchase this power at the utilities' marginal (or ''avoided'') cost. PURPA 210 has clearly had a major impact as measured by the actual and proposed number of new qualifying facilities; however, implementation has been difficult due to the adversarial nature of the process for negotiating ormore » setting the avoided cost rates. This paper reviews the pertinent PURPA rules and regulations, analyzes the status of current avoided cost rates that have been established, and discusses implementation issues and options for resolving those issues.« less

  4. Designing PURPA (Public Utilities Regulatory Act) power purchase auctions: Theory and practice. [Cogenerated electricity purchasing model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothkopf, M.H.; Kahn, E.P.; Teisberg, T.J.

    The Public Utilities Regulatory Act (PURPA) requires there to be procedures for electric utilities to buy electric power from qualifying cogenerators and small power producers (QFs) at rates up to ''avoided cost.'' This has led to price-posting procedures at prices calculated as the utility's marginal cost. Unexpectedly large sales at these prices and slow adjustment to falling energy cost are partially responsible for payments to QFs in excess of the utility's true avoided cost. Using competitive bidding instead of posted prices has been proposed as a way to avoid this outcome. This report reviews bidding theory and explores four issuesmore » that arise in deisigning auction systems for the purchase of power from QFs under PURPA. 77 refs., 6 figs., 15 tabs.« less

  5. EDF experience with {open_quotes}hot spot{close_quotes} management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guio, J.M. de

    1995-03-01

    During the past few years, {open_quotes}hot spots{close_quotes} due to the presence of particles of metal activated during their migration through the reactor core, have been detected at several French pressurized water reactor (PWR) units. These {open_quotes}hot spots,{close_quotes} which generate very high dose rates (from about 10 Gy/h to 200 G/h) are a significant factor in increase occupational exposures during outrates. Of particular concern are the difficult cases which prolong outage duration and increase the volume of radiological waste. Confronted with this situation, Electricite de France (EDF) has set up a national research group, as part of its ALARA program, tomore » establish procedures and techniques to avoid, detect, and eliminate of hot spots. In particular, specific processes have been developed to eliminate these hot spots which are most costly in terms of occupational exposure due to the need for reactor maintenance. This paper sets out the general approach adopted at EDF so far to cope with the problem of hot spots, illustrated by experience at Blayais 3 and 4.« less

  6. Considerations for an Earth Relay Satellite with RF and Optical Trunklines

    NASA Technical Reports Server (NTRS)

    Israel, David J.

    2016-01-01

    Support for user platforms through the use of optical links to geosynchronous relay spacecraft are expected to be part of the future space communications architecture. The European Data Relay Satellite System (EDRS) has its first node, EDRS-A, in orbit. The EDRS architecture includes space-to-space optical links with a Ka-Band feeder link or trunkline. NASA's Laser Communications Relay Demonstration (LCRD) mission, originally baselined to support a space-to-space optical link relayed with an optical trunkline, has added an Radio Frequency (RF) trunkline. The use of an RF trunkline avoids the outages suffered by an optical trunkline due to clouds, but an RF trunkline will be bandwidth limited. A space relay architecture with both RF and optical trunklines could relay critical realtime data, while also providing a high data volume capacity. This paper considers the relay user scenarios that could be supported, and the implications to the space relay system and operations. System trades such as the amount of onboard processing and storage required, the use of link layer switching vs. network layer routing, and the use of Delay/Disruption Tolerant Networking (DTN) are discussed.

  7. Health impact assessment of cyclone Bejisa in Reunion Island (France) using syndromic surveillance.

    PubMed

    Vilain, Pascal; Pagès, Frédéric; Combes, Xavier; Marianne Dit Cassou, Pierre-Jean; Mougin-Damour, Katia; Jacques-Antoine, Yves; Filleul, Laurent

    2015-04-01

    On January 2, 2014, Cyclone Bejisa struck Reunion Island (France). This storm led to major material damages, such as power outages, disturbance of drinking water systems, road closures, and the evacuation of residents. In this context, the Regional Office of French Institute for Public Health Surveillance in Indian Ocean (Cire OI) set up an epidemiological surveillance in order to describe short-term health effects of the cyclone. The assessment of the health impact was based mainly on a syndromic surveillance system, including the activity of all emergency departments (EDs) and the Emergency Medical Service (EMS) of the island. From these data, several health indicators were collected and analyzed daily and weekly. To complete this assessment, all medical charts recorded in the EDs of Reunion Island from January 2, 2014 through January 5, 2014 were reviewed in order to identify visits directly and indirectly related to the cyclone, and to determine mechanisms of injuries. The number of calls to the EMS peaked the day of the cyclone, and the number of ED visits increased markedly over the next two days. At the same time, a significant increase in visits for trauma, burns, and carbon monoxide poisoning was detected in all EDs. Among 1,748 medical records reviewed, eight visits were directly related to the cyclone and 208 were indirectly related. For trauma, the main mechanisms of injury were falls and injuries by machinery or tools during the clean-up and repair works. Due to prolonged power outages, several patients were hospitalized: some to assure continuity of care, others to take care of an exacerbation of a chronic disease. An increase in leptospirosis cases linked to post-cyclone clean-up was observed two weeks after the cyclone. Information based on the syndromic surveillance system allowed the authors to assess rapidly the health impact of Cyclone Bejisa in Reunion Island; however, an underestimation of this impact was still possible. In the near future, several lines of work will be planned by the authors in order to improve the assessment.

  8. 47 CFR 74.803 - Frequency selection to avoid interference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Frequency selection to avoid interference. 74... Power Auxiliary Stations § 74.803 Frequency selection to avoid interference. (a) Where two or more low... frequencies or schedule operation in such manner as to avoid mutual interference. If a mutually satisfactory...

  9. 47 CFR 74.803 - Frequency selection to avoid interference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Frequency selection to avoid interference. 74... Power Auxiliary Stations § 74.803 Frequency selection to avoid interference. (a) Where two or more low... frequencies or schedule operation in such manner as to avoid mutual interference. If a mutually satisfactory...

  10. Avoidance behavior by prairie grouse: implications for development of wind energy.

    PubMed

    Pruett, Christin L; Patten, Michael A; Wolfe, Donald H

    2009-10-01

    New wind-energy facilities and their associated power transmission lines and roads are being constructed at a rapid pace in the Great Plains of North America. Nevertheless, little is known about the possible negative effects these anthropogenic features might have on prairie birds, one of the most threatened groups in North America. We examined radiotelemetry tracking locations of Lesser Prairie-Chickens (Tympanuchus pallidicinctus) and Greater Prairie-Chickens (T. cupido) in two locations in Oklahoma to determine whether these birds avoided or changed movement behavior near power lines and paved highways. We tracked 463 Lesser Prairie-Chickens (15,071 tracking locations) and 216 Greater Prairie-Chickens (5,750 locations) for 7 and 3 years, respectively. Individuals of both species avoided power lines by at least 100 m and Lesser Prairie-Chickens avoided one of the two highways by 100 m. Prairie-chickens crossed power lines less often than expected if birds moved randomly (p < 0.05) but did not appear to perceive highways as a movement barrier (p > 0.05). In addition, home ranges of Lesser Prairie-Chickens overlapped the power line less often than would be expected by chance placement of home ranges; this result was supported by kernel-density estimation of home ranges. It is likely that new power lines (and other tall structures such as wind turbines) will lead to avoidance of previously suitable habitat and will serve as barriers to movement. These two factors will likely increase fragmentation in an already fragmented landscape if wind energy development continues in prairie habitats.

  11. Requirements for a transformerless power conditioning system

    NASA Technical Reports Server (NTRS)

    Klein, J.; Koerner, T.; Rippel, W.; Kalbach, J.

    1984-01-01

    Requirements for development of a Transformerless Power Conditioning Subsystem (TPCS) that will meet utility, manufacturer, and customer needs are detailed. Issues analyzed include current utility guidelines, safety and grounding issues that appear as local codes, various kinds of TPCS connections that can be developed, dc injection, and a brief survey of TPCS circuit topologies that will meet requirements. The major result is that a finite time exists for control operation before dc injection into the distribution transformer causes customer outage (on the order of seconds). This time permits the control system to sense a dc injection condition and remove the TPCS from the utility system. Requirements for such a control system are specified. A three wire connection will ensure balanced operation for customer loads and two wire connections caused average value dc to be injected into single phase loads. This type of connection also allows for the lowest array voltage. The conclusion is that requirements for a TPCS can be determined and that there are not showstopping issues preventing implementation. The actual design and topology of the TPCS was left for further study.

  12. Preparedness for natural disasters among older US adults: a nationwide survey.

    PubMed

    Al-Rousan, Tala M; Rubenstein, Linda M; Wallace, Robert B

    2015-10-01

    We sought to determine natural disaster preparedness levels among older US adults and assess factors that may adversely affect health and safety during such incidents. We sampled adults aged 50 years or older (n = 1304) from the 2010 interview survey of the Health and Retirement Study. The survey gathered data on general demographic characteristics, disability status or functional limitations, and preparedness-related factors and behaviors. We calculated a general disaster preparedness score by using individual indicators to assess overall preparedness. Participant (n = 1304) mean age was 70 years (SD = 9.3). Only 34.3% reported participating in an educational program or reading materials about disaster preparation. Nearly 15% reported using electrically powered medical devices that might be at risk in a power outage. The preparedness score indicated that increasing age, physical disability, and lower educational attainment and income were independently and significantly associated with worse overall preparedness. Despite both greater vulnerability to disasters and continuous growth in the number of older US adults, many of the substantial problems discovered are remediable and require attention in the clinical, public health, and emergency management sectors of society.

  13. [Preparedness for natural disasters among older US adults: a nationwide survery].

    PubMed

    Al-rousan, Tala M; Rubenstein, Linda M; Wallace, Robert B

    2014-12-01

    We sought to determine natural disaster preparedness levels among older US adults and assess factors that may adversely affect health and safety during such incidents. We sampled adults aged 50 years or older (n = 1 304) from the 2010 interview survey of the Health and Retirement Study. The survey gathered data on general demographic characteristics, disability status or functional limitations, and preparedness-related factors and behaviors. We calculated a general disaster preparedness score by using individual indicators to assess overall preparedness. Participant (n = 1 304) mean age was 70 years (SD = 9.3). Only 34.3% reported participating in an educational program or reading materials about disaster preparation. Nearly 15% reported using electrically powered medical devices that might be at risk in a power outage. The preparedness score indicated that increasing age, physical disability, and lower educational attainment and income were independently and significantly associated with worse overall preparedness. Despite both greater vulnerability to disasters and continuous growth in the number of older US adults, many of the substantial problems discovered are remediable and require attention in the clinical, public health, and emergency management sectors of society.

  14. Resilient Distribution System by Microgrids Formation After Natural Disasters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chen; Wang, Jianhui; Qiu, Feng

    2016-03-01

    Microgrids with distributed generation provide a resilient solution in the case of major faults in a distribution system due to natural disasters. This paper proposes a novel distribution system operational approach by forming multiple microgrids energized by distributed generation from the radial distribution system in real-time operations, to restore critical loads from the power outage. Specifically, a mixed-integer linear program (MILP) is formulated to maximize the critical loads to be picked up while satisfying the self-adequacy and operation constraints for the microgrids formation problem, by controlling the ON/OFF status of the remotely controlled switch devices and distributed generation. A distributedmore » multi-agent coordination scheme is designed via local communications for the global information discovery as inputs of the optimization, which is suitable for autonomous communication requirements after the disastrous event. The formed microgrids can be further utilized for power quality control and can be connected to a larger microgrid before the restoration of the main grids is complete. Numerical results based on modified IEEE distribution test systems validate the effectiveness of our proposed scheme.« less

  15. Pipe degradation investigations for optimization of flow-accelerated corrosion inspection location selection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandra, S.; Habicht, P.; Chexal, B.

    1995-12-01

    A large amount of piping in a typical nuclear power plant is susceptible to Flow-Accelerated Corrosion (FAC) wall thinning to varying degrees. A typical PAC monitoring program includes the wall thickness measurement of a select number of components in order to judge the structural integrity of entire systems. In order to appropriately allocate resources and maintain an adequate FAC program, it is necessary to optimize the selection of components for inspection by focusing on those components which provide the best indication of system susceptibility to FAC. A better understanding of system FAC predictability and the types of FAC damage encounteredmore » can provide some of the insight needed to better focus and optimize the inspection plan for an upcoming refueling outage. Laboratory examination of FAC damaged components removed from service at Northeast Utilities` (NU) nuclear power plants provides a better understanding of the damage mechanisms involved and contributing causes. Selected results of this ongoing study are presented with specific conclusions which will help NU to better focus inspections and thus optimize the ongoing FAC inspection program.« less

  16. Carbon Monoxide Epidemic Among Immigrant Populations: King County, Washington, 2006

    PubMed Central

    Kwan-Gett, Tao; Hampson, Neil B.; Baer, Atar; Shusterman, Dennis; Shandro, Jamie R.; Duchin, Jeffrey S.

    2009-01-01

    Objectives. We investigated an outbreak of carbon monoxide (CO) poisoning after a power outage to determine its extent, identify risk factors, and develop prevention measures. Methods. We reviewed medical records and medical examiner reports of patients with CO poisoning or related symptoms during December 15 to 24, 2006. We grouped patients into households exposed concurrently to a single source of CO. Results. Among 259 patients with CO poisoning, 204 cases were laboratory confirmed, 37 were probable, 10 were suspected, and 8 were fatal. Of 86 households studied, 58% (n = 50) were immigrant households from Africa (n = 21), Asia (n = 15), Latin America (n = 10), and the Middle East (n = 4); 34% (n = 29) were US-born households. One percent of households was European (n = 1), and the origin for 7% (n = 6) was unknown. Charcoal was the most common fuel source used among immigrant households (82%), whereas liquid fuel was predominant among US-born households (34%). Conclusions. Educational campaigns to prevent CO poisoning should consider immigrants’ cultural practices and languages and specifically warn against burning charcoal indoors and incorrect ventilation of gasoline- or propane-powered electric generators. PMID:19608962

  17. All About PID - Testing and Avoidance in the Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacke, Peter; Johnston, Steve

    2016-09-01

    Potential-induced degradation can cause significant power loss in modules if the appropriate precautions are not taken. In the first part of a new series in PV Tech Power on module failure, Peter Hacke and Steve Johnston assess the current state-of-the-art in detecting, avoiding and mitigating the worst effects of PID.

  18. Leaders Behaving Badly: Using Power to Generate Undiscussables in Action Learning Sets

    ERIC Educational Resources Information Center

    Donovan, Paul Jeffrey

    2014-01-01

    "Undiscussables" are topics associated with threat or embarrassment that are avoided by groups, where that avoidance is also not discussed. Their deleterious effect on executive groups has been a point of discussion for several decades. More recently critical action learning (AL) has brought a welcome focus to power relations within AL…

  19. Data Relay Board with Protocol for High-Speed, Free-Space Optical Communications

    NASA Technical Reports Server (NTRS)

    Wright, Malcolm; Clare, Loren; Gould, Gary; Pedyash, Maxim

    2004-01-01

    In a free-space optical communication system, the mitigation of transient outages through the incorporation of error-control methods is of particular concern, the outages being caused by scintillation fades and obscurants. The focus of this innovative technology is the development of a data relay system for a reliable high-data-rate free-spacebased optical-transport network. The data relay boards will establish the link, maintain synchronous connection, group the data into frames, and provide for automatic retransmission (ARQ) of lost or erred frames. A certain Quality of Service (QoS) can then be ensured, compatible with the required data rate. The protocol to be used by the data relay system is based on the draft CCSDS standard data-link protocol Proximity-1, selected by orbiters to multiple lander assets in the Mars network, for example. In addition to providing data-link protocol capabilities for the free-space optical link and buffering the data, the data relay system will interface directly with user applications over Gigabit Ethernet and/or with highspeed storage resources via Fibre Channel. The hardware implementation is built on a network-processor-based architecture. This technology combines the power of a hardware switch capable of data switching and packet routing at Gbps rates, with the flexibility of a software- driven processor that can host highly adaptive and reconfigurable protocols used, for example, in wireless local-area networks (LANs). The system will be implemented in a modular multi-board fashion. The main hardware elements of the data relay system are the new data relay board developed by Rockwell Scientific, a COTS Gigabit Ethernet board for user interface, and a COTS Fibre Channel board that connects to local storage. The boards reside in a cPCI back plane, and can be housed in a VME-type enclosure.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreitman, Paul J.; Sirianni, Steve R.; Pillard, Mark M.

    Entergy recently performed an Extended Power Up-rate (EPU) on their Grand Gulf Nuclear Station, near Port Gibson, Mississippi. To support the EPU, a new Steam Dryer Assembly was installed during the last refueling outage. Due to limited access into the containment, the large Replacement Steam Dryer (RSD) had to be brought into the containment in pieces and then final assembly was completed on the refueling floor before installation into the reactor. Likewise, the highly contaminated Original Steam Dryer (OSD) had to be segmented into manageable sections, loaded into specially designed shielded containers, and rigged out of containment where they willmore » be safely stored until final disposal is accomplished at an acceptable waste repository. Westinghouse Nuclear Services was contracted by Entergy to segment, package and remove the OSD from containment. This work was performed on critical path during the most recent refueling outage. The segmentation was performed underwater to minimize radiation exposure to the workers. Special hydraulic saws were developed for the cutting operations based on Westinghouse designs previously used in Sweden to segment ABB Reactor Internals. The mechanical cutting method was selected because of its proven reliability and the minimal cutting debris that is generated by the process. Maintaining stability of the large OSD sections during cutting was accomplished using a custom built support stand that was installed into the Moisture Separator Pool after the Moisture Separator was installed back in the reactor vessel. The OSD was then moved from the Steam Dryer Pool to the Moisture Separator Pool for segmentation. This scenario resolved the logistical challenge of having two steam dryers and a moisture separator in containment simultaneously. A water filtration/vacuum unit was supplied to maintain water clarity during the cutting and handling operations and to collect the cutting chips. (authors)« less

  1. Successful multi-technology NO{sub x} reduction project experience at New England Power Company - Salem Harbor station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fynan, G.A.; Sload, A.; Adamson, E.J.

    This paper presents the successes and lessons learned during recent low NOx burner and SNCR projects on generating units at New England Power`s Salem Harbor Generating Station. The principals involved in the project were New England Power Company, New England Power Service Company, Stone and Webster Engineering Corp. and Deutsche-Babcock Riley Inc. One unit was retrofitted with 16 Riley CCV burners with an OFA system, the other with 12 low NOx burners only. In addition to the burners, a SNCR system was also installed on three units. Since each of the burner systems are interdependent (SNCR was treated separately duringmore » design phases and optimized along with the burner systems), close cooperation during the design stages was essential to ensuring a successful installation, startup and optimization. This paper will present the coordinated effort put forth by each company toward this goal with the hope of assisting others who may be planning a similar effort. A summary of the operating results will also be presented. The up front teamwork and advance planning that went into the design stages of the project resulted in a number of successful outcomes e.g. scanner reliability, properly operating oil supply system, compatibility of burners and burner front oil system with new Burner Management System (BMS), reliable first attempt burner ignition and more. Advance planning facilitated pre-outage work and factored into keeping schedules and budgets on track.« less

  2. Foundational Report Series. Advanced Distribution management Systems for Grid Modernization (Importance of DMS for Distribution Grid Modernization)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jianhui

    2015-09-01

    Grid modernization is transforming the operation and management of electric distribution systems from manual, paper-driven business processes to electronic, computer-assisted decisionmaking. At the center of this business transformation is the distribution management system (DMS), which provides a foundation from which optimal levels of performance can be achieved in an increasingly complex business and operating environment. Electric distribution utilities are facing many new challenges that are dramatically increasing the complexity of operating and managing the electric distribution system: growing customer expectations for service reliability and power quality, pressure to achieve better efficiency and utilization of existing distribution system assets, and reductionmore » of greenhouse gas emissions by accommodating high penetration levels of distributed generating resources powered by renewable energy sources (wind, solar, etc.). Recent “storm of the century” events in the northeastern United States and the lengthy power outages and customer hardships that followed have greatly elevated the need to make power delivery systems more resilient to major storm events and to provide a more effective electric utility response during such regional power grid emergencies. Despite these newly emerging challenges for electric distribution system operators, only a small percentage of electric utilities have actually implemented a DMS. This paper discusses reasons why a DMS is needed and why the DMS may emerge as a mission-critical system that will soon be considered essential as electric utilities roll out their grid modernization strategies.« less

  3. A hybrid localization technique for patient tracking.

    PubMed

    Rodionov, Denis; Kolev, George; Bushminkin, Kirill

    2013-01-01

    Nowadays numerous technologies are employed for tracking patients and assets in hospitals or nursing homes. Each of them has advantages and drawbacks. For example, WiFi localization has relatively good accuracy but cannot be used in case of power outage or in the areas with poor WiFi coverage. Magnetometer positioning or cellular network does not have such problems but they are not as accurate as localization with WiFi. This paper describes technique that simultaneously employs different localization technologies for enhancing stability and average accuracy of localization. The proposed algorithm is based on fingerprinting method paired with data fusion and prediction algorithms for estimating the object location. The core idea of the algorithm is technology fusion using error estimation methods. For testing accuracy and performance of the algorithm testing simulation environment has been implemented. Significant accuracy improvement was showed in practical scenarios.

  4. The Mysterious Origins of Solar Flares: New observations are beginning to reveal what triggers these hughes explosions of the sun's atmosphere

    NASA Technical Reports Server (NTRS)

    Holman, Gordon D.

    2006-01-01

    Solar flares can release the energy equivalent of billions of atomic bombs in the span of just a few minutes. These explosions give off a burst of x-rays and charged particles, some of which may later hit Earth, endangering satellites and causing power outages. The sun's tumultuous magnetic fields provide the fuel of flares. The sudden release of energy in a flare results from a process called reconnection, whereby oppositely directed magnetic field lines come together and partially annihilate each other. Although theoretical studies of magnetic reconnection on the sun have been carried out for decades, only recently have space probes uncovered observational evidence for this phenomenon. The telltale signs include pointed magnetic loops located below the spot where magnetic reconnection is taking place.

  5. Using Medicare data to identify individuals who are electricity dependent to improve disaster preparedness and response.

    PubMed

    DeSalvo, Karen; Lurie, Nicole; Finne, Kristen; Worrall, Chris; Bogdanov, Alina; Dinkler, Ayame; Babcock, Sarah; Kelman, Jeffrey

    2014-07-01

    During a disaster or prolonged power outage, individuals who use electricity-dependent medical equipment are often unable to operate it and seek care in acute care settings or local shelters. Public health officials often report that they do not have proactive and systematic ways to rapidly identify and assist these individuals. In June 2013, we piloted a first-in-the-nation emergency preparedness drill in which we used Medicare claims data to identify individuals with electricity-dependent durable medical equipment during a disaster and securely disclosed it to a local health department. We found that Medicare claims data were 93% accurate in identifying individuals using a home oxygen concentrator or ventilator. The drill findings suggest that claims data can be useful in improving preparedness and response for electricity-dependent populations.

  6. Detection of emerging sunspot regions in the solar interior.

    PubMed

    Ilonidis, Stathis; Zhao, Junwei; Kosovichev, Alexander

    2011-08-19

    Sunspots are regions where strong magnetic fields emerge from the solar interior and where major eruptive events occur. These energetic events can cause power outages, interrupt telecommunication and navigation services, and pose hazards to astronauts. We detected subsurface signatures of emerging sunspot regions before they appeared on the solar disc. Strong acoustic travel-time anomalies of an order of 12 to 16 seconds were detected as deep as 65,000 kilometers. These anomalies were associated with magnetic structures that emerged with an average speed of 0.3 to 0.6 kilometer per second and caused high peaks in the photospheric magnetic flux rate 1 to 2 days after the detection of the anomalies. Thus, synoptic imaging of subsurface magnetic activity may allow anticipation of large sunspot regions before they become visible, improving space weather forecast.

  7. Using Medicare Data to Identify Individuals Who Are Electricity Dependent to Improve Disaster Preparedness and Response

    PubMed Central

    DeSalvo, Karen; Finne, Kristen; Worrall, Chris; Bogdanov, Alina; Dinkler, Ayame; Babcock, Sarah; Kelman, Jeffrey

    2014-01-01

    During a disaster or prolonged power outage, individuals who use electricity-dependent medical equipment are often unable to operate it and seek care in acute care settings or local shelters. Public health officials often report that they do not have proactive and systematic ways to rapidly identify and assist these individuals. In June 2013, we piloted a first-in-the-nation emergency preparedness drill in which we used Medicare claims data to identify individuals with electricity-dependent durable medical equipment during a disaster and securely disclosed it to a local health department. We found that Medicare claims data were 93% accurate in identifying individuals using a home oxygen concentrator or ventilator. The drill findings suggest that claims data can be useful in improving preparedness and response for electricity-dependent populations. PMID:24832404

  8. High-Rate Communications Outage Recorder Operations for Optimal Payload and Science Telemetry Management Onboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Shell, Michael T.; McElyea, Richard M. (Technical Monitor)

    2002-01-01

    All International Space Station (ISS) Ku-band telemetry transmits through the High-Rate Communications Outage Recorder (HCOR). The HCOR provides the recording and playback capability for all payload, science, and International Partner data streams transmitting through NASA's Ku-band antenna system. The HCOR is a solid-state memory recorder that provides recording capability to record all eight ISS high-rate data during ISS Loss-of-Signal periods. NASA payloads in the Destiny module are prime users of the HCOR; however, NASDA and ESA will also utilize the HCOR for data capture and playback of their high data rate links from the Kibo and Columbus modules. Marshall Space Flight Center's Payload Operations Integration Center manages the HCOR for nominal functions, including system configurations and playback operations. The purpose of this paper is to present the nominal operations plan for the HCOR and the plans for handling contingency operations affecting payload operations. In addition, the paper will address HCOR operation limitations and the expected effects on payload operations. The HCOR is manifested for ISS delivery on flight 9A with the HCOR backup manifested on flight 11A. The HCOR replaces the Medium-Rate Communications Outage Recorder (MCOR), which has supported payloads since flight 5A.1.

  9. Impact of nonzero boresight pointing errors on the performance of a relay-assisted free-space optical communication system over exponentiated Weibull fading channels.

    PubMed

    Wang, Ping; Liu, Xiaoxia; Cao, Tian; Fu, Huihua; Wang, Ranran; Guo, Lixin

    2016-09-20

    The impact of nonzero boresight pointing errors on the system performance of decode-and-forward protocol-based multihop parallel optical wireless communication systems is studied. For the aggregated fading channel, the atmospheric turbulence is simulated by an exponentiated Weibull model, and pointing errors are described by one recently proposed statistical model including both boresight and jitter. The binary phase-shift keying subcarrier intensity modulation-based analytical average bit error rate (ABER) and outage probability expressions are achieved for a nonidentically and independently distributed system. The ABER and outage probability are then analyzed with different turbulence strengths, receiving aperture sizes, structure parameters (P and Q), jitter variances, and boresight displacements. The results show that aperture averaging offers almost the same system performance improvement with boresight included or not, despite the values of P and Q. The performance enhancement owing to the increase of cooperative path (P) is more evident with nonzero boresight than that with zero boresight (jitter only), whereas the performance deterioration because of the increasing hops (Q) with nonzero boresight is almost the same as that with zero boresight. Monte Carlo simulation is offered to verify the validity of ABER and outage probability expressions.

  10. Simulating Global AeroMACS Airport Ground Station Antenna Power Transmission Limits to Avoid Interference With Mobile Satellite Service Feeder Uplinks

    NASA Technical Reports Server (NTRS)

    Wilson, Jeffrey D.

    2013-01-01

    The Aeronautical Mobile Airport Communications System (AeroMACS), which is based upon the IEEE 802.16e mobile wireless standard, is expected to be implemented in the 5091 to 5150 MHz frequency band. As this band is also occupied by Mobile Satellite Service feeder uplinks, AeroMACS must be designed to avoid interference with this incumbent service. The aspects of AeroMACS operation that present potential interference are under analysis in order to enable the definition of standards that assure that such interference will be avoided. In this study, the cumulative interference power distribution at low Earth orbit from transmitters at global airports was simulated with the Visualyse Professional software. The dependence of the interference power on antenna distribution, gain patterns, duty cycle, and antenna tilt was simulated. As a function of these parameters, the simulation results are presented in terms of the limitations on transmitter power from global airports required to maintain the cumulative interference power under the established threshold.

  11. An online dispatcher training simulator function for real-time analysis and training

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vadari, S.V.; Montstream, M.J.; Ross, H.B. Jr.

    1995-11-01

    Today`s power systems have become so complex that it is not easy for the system dispatcher to realistically predict the results of outages. The situation is compounded whenever the power grid is not in its normal configuration due to maintenance switching or equipment failure. The authors feel that the DTS is an excellent tool that can be used to teach the dispatcher how to react under these conditions. In this paper, the authors present an on-line implementation of the DTS which allows the user to initialize the DTS to an EMS disturbance using data that was captured at the timemore » of the disturbance; and place the DTS in a playback mode and go back to specific times in the scenario. The former feature allows the analyst to investigate EMS disturbances and then train the various dispatchers to be able to recognize such disturbances and to recover from them when they occur. The latter feature allows the instructor (with the trainee) to review and re-experience desired portions of the scenario. It is the authors` feeling that these two features will help the EMS operational staff understand their power system better and help their dispatchers in dealing with operational problems associated with the proper running of the system.« less

  12. Improved Emergency Egress Lighting System for the ISS

    NASA Technical Reports Server (NTRS)

    Eaton, Leslie L.; Barr, Don A.

    2005-01-01

    Emergency lights provide illumination in corridors, stairwells, ramps, escalators, aisles, and exit passageways during power failures. Safety and visibility are critical during a power outage. If emergency lights fail to operate properly, the building occupants can become disoriented. Four documents in a collection discuss different topics relating to a proposed improved emergency egress lighting system (EELS) for the International Space Station (ISS). While the present EELS is designed around rows of green-light-emitting diodes, the proposed system contains strips of electroluminescent tape using different colors for each egress path. The proposed EELS can be powered by the same battery currently used by the present EELS, but would require an inverter because electroluminescent devices require AC. Electroluminescent devices also require significantly less current and, depending on the color, would emit 3 to 8 times the light of the present EELS. In addition, they could operate for up to 75 hours (versus .20 minutes for the present system). The first document contains a one-page summary of the proposal and an evaluation of technical merit. The second document summarizes the motivation for, and the design of, the proposed EELS. The third document addresses relevant aspects of the measurement of spectral sensitivity and the psychophysics of perception of light. The fourth document presents additional background information and technical specifications for the electroluminescent tapes.

  13. Power Moves Beyond Complementarity: A Staring Look Elicits Avoidance in Low Power Perceivers and Approach in High Power Perceivers

    PubMed Central

    Weick, Mario; McCall, Cade; Blascovich, Jim

    2017-01-01

    Sustained, direct eye-gaze—staring—is a powerful cue that elicits strong responses in many primate and nonprimate species. The present research examined whether fleeting experiences of high and low power alter individuals’ spontaneous responses to the staring gaze of an onlooker. We report two experimental studies showing that sustained, direct gaze elicits spontaneous avoidance tendencies in low power perceivers and spontaneous approach tendencies in high power perceivers. These effects emerged during interactions with different targets and when power was manipulated between-individuals (Study 1) and within-individuals (Study 2), thus attesting to a high degree of flexibility in perceivers’ reactions to gaze cues. Together, the present findings indicate that power can break the cycle of complementarity in individuals’ spontaneous responding: Low power perceivers complement and move away from, and high power perceivers reciprocate and move toward, staring onlookers. PMID:28903712

  14. Discontinuous Mode Power Supply

    NASA Technical Reports Server (NTRS)

    Lagadinos, John; Poulos, Ethel

    2012-01-01

    A document discusses the changes made to a standard push-pull inverter circuit to avoid saturation effects in the main inverter power supply. Typically, in a standard push-pull arrangement, the unsymmetrical primary excitation causes variations in the volt second integral of each half of the excitation cycle that could lead to the establishment of DC flux density in the magnetic core, which could eventually cause saturation of the main inverter transformer. The relocation of the filter reactor normally placed across the output of the power supply solves this problem. The filter reactor was placed in series with the primary circuit of the main inverter transformer, and is presented as impedance against the sudden changes on the input current. The reactor averaged the input current in the primary circuit, avoiding saturation of the main inverter transformer. Since the implementation of the described change, the above problem has not reoccurred, and failures in the main power transistors have been avoided.

  15. Fuel Cell Power Plant Initiative. Volume 1; Solid Oxide Fuel Cell/Logistics Fuel Processor 27 kWe Power System Demonstration for ARPA

    NASA Technical Reports Server (NTRS)

    Veyo, S.E.

    1997-01-01

    This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The report provides highlights related to impacts of Hurricane Frances and Hurricane Ivan in the Florida area. Sections on electric information, oil and gas information, and county outage data are provided.

  17. Fuzzy Inference Based Obstacle Avoidance Control of Electric Powered Wheelchair Considering Driving Risk

    NASA Astrophysics Data System (ADS)

    Kiso, Atsushi; Murakami, Hiroki; Seki, Hirokazu

    This paper describes a novel obstacle avoidance control scheme of electric powered wheelchairs for realizing the safe driving in various environments. The “electric powered wheelchair” which generates the driving force by electric motors is expected to be widely used as a mobility support system for elderly people and disabled people; however, the driving performance must be further improved because the number of driving accidents caused by elderly operator's narrow sight and joystick operation errors is increasing. This paper proposes a novel obstacle avoidance control scheme based on fuzzy algorithm to prevent driving accidents. The proposed control system determines the driving direction by fuzzy algorithm based on the information of the joystick operation and distance to obstacles measured by ultrasonic sensors. Fuzzy rules to determine the driving direction are designed surely to avoid passers-by and walls considering the human's intent and driving environments. Some driving experiments on the practical situations show the effectiveness of the proposed control system.

  18. Cultural Variance as a Challenge to Global Public Relations: A Case Study of the Coca-Cola Scare in Europe.

    ERIC Educational Resources Information Center

    Taylor, Maureen

    2000-01-01

    Explores cultural variability, especially uncertainty avoidance and power distance, and examines how it affects public response to crisis. Presents an analysis of the national cultures of six European countries that showed that publics who live in nations that are high in uncertainty avoidance and power distance tend to react more strongly, and…

  19. Climate and Water Vulnerability of the US Electricity Grid Under High Penetrations of Renewable Energy

    NASA Astrophysics Data System (ADS)

    Macknick, J.; Miara, A.; O'Connell, M.; Vorosmarty, C. J.; Newmark, R. L.

    2017-12-01

    The US power sector is highly dependent upon water resources for reliable operations, primarily for thermoelectric cooling and hydropower technologies. Changes in the availability and temperature of water resources can limit electricity generation and cause outages at power plants, which substantially affect grid-level operational decisions. While the effects of water variability and climate changes on individual power plants are well documented, prior studies have not identified the significance of these impacts at the regional systems-level at which the grid operates, including whether there are risks for large-scale blackouts, brownouts, or increases in production costs. Adequately assessing electric grid system-level impacts requires detailed power sector modeling tools that can incorporate electric transmission infrastructure, capacity reserves, and other grid characteristics. Here, we present for the first time, a study of how climate and water variability affect operations of the power sector, considering different electricity sector configurations (low vs. high renewable) and environmental regulations. We use a case study of the US Eastern Interconnection, building off the Eastern Renewable Generation Integration Study (ERGIS) that explored operational challenges of high penetrations of renewable energy on the grid. We evaluate climate-water constraints on individual power plants, using the Thermoelectric Power and Thermal Pollution (TP2M) model coupled with the PLEXOS electricity production cost model, in the context of broader electricity grid operations. Using a five minute time step for future years, we analyze scenarios of 10% to 30% renewable energy penetration along with considerations of river temperature regulations to compare the cost, performance, and reliability tradeoffs of water-dependent thermoelectric generation and variable renewable energy technologies under climate stresses. This work provides novel insights into the resilience and reliability of different configurations of the US electric grid subject to changing climate conditions.

  20. Planning for Power.

    ERIC Educational Resources Information Center

    Failla, Victor A.; Birk, Thomas A.

    1999-01-01

    Discusses the electrical power problems that can arise when schools try to integrate educational technology components into an existing facility, and how to plan the electrical power design to avoid power failures. Examines setting objectives, evaluating current electrical conditions, and developing the technology power design. (GR)

  1. Energy Infrastructure and Extreme Events (Invited)

    NASA Astrophysics Data System (ADS)

    Wakimoto, R. M.

    2013-12-01

    The country's energy infrastructure is sensitive to the environment, especially extreme events. Increasing global temperatures, intense storms, and space weather have the potential to disrupt energy production and transport. It can also provide new opportunities as illustrated by the opening of the Northwest Passage. The following provides an overview of some of the high impacts of major geophysical events on energy production and transport. Future predictions of hurricanes suggest that we can expect fewer storms but they will be associated with stronger winds and more precipitation. The winds and storm surge accompanying hurricane landfall along the Gulf States has had a major impact on the coastal energy infrastructure and the oil/natural gas platforms. The impact of these surges will increase with predicted sea level rise. Hurricane Katrina caused damage to crude oil pipelines and refineries that reduced oil production by 19% for the year. The disruption that can occur is not necessarily linked with the maximum winds of the tropical storm as recently shown by Hurricane Sandy which was classified as a ';post-tropical cyclone' during landfall. Another intense circulation, the tornado, can also cause power outages and network breaks from high winds that can topple power poles or damage power lines from fallen trees. Fortunately, the Moore tornado, rated EF5, did not have a major impact on the oil and gas infrastructure in Oklahoma. The impact of earthquakes and tsunamis on energy was illustrated in Japan in 2011 with the shutdown of the Fukushima Daiichi plant. Other studies have suggested that there are areas in the United States where the energy services are highly vulnerable to major earthquakes that would disrupt electrical and gas networks for extended periods of time. Seismic upgrades to the energy infrastructure would help mitigate the impact. In 1859, a coronal mass ejection triggered a geomagnetic storm that disrupted communication wires around the world. It has been suggested that this event would be associated with massive power outages if it occurred today. A similar storm would create strong electrical currents that would travel through power lines, oil pipelines and telecom cables. Transformers would fail and large sections of the electric grid would go down. The melting of the Artic ice has opened the Northwest Passage for increasing periods of time making it an attractive alternative route for tankers and commercial ships. In addition, there is a high potential for tapping into new oil and gas reserves. However, these new opportunities need to be balanced with an analysis of the environmental risks posed by exploration, drilling and increased traffic in a region that until recently was difficult to access. Increasing temperatures coupled with longer periods of drought has increased the wildfire risk to transmission lines. Studies are currently underway that quantify the probability that transmission lines would be impacted by fire. Not discussed in this overview are other impacts that have been well documented. Higher temperatures in the summer will increase the electricity demand for cooling but will also reduce energy demand for heating in the winter. Severe droughts limits the access to water that are needed to cool power plants. Precipitation variability and reduced snowpack limits the ability to generate power from hydroelectric plants.

  2. Inconel 690 is alloy of choice for steam-generator tubing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, S.D.

    1996-02-01

    The product of two decades of research and plant application, Inconel 690 promises superior long-term resistance to tube cracking in comparison to alloy 600. Ongoing steam-generator management techniques applied at nuclear pressurized-water-reactor (PWR) plants focus on tube monitoring, inspection, and repair, and on water-chemistry control. Of greatest concern to owner/operators of steam generators (SGs) with recirculating (U-bend) rather than straight through tubes is corrosion of several forms, including pitting, thinning, and cracking. As problems persist and operating and maintenance (O and M) costs become prohibitive, managers must consider the remaining option: complete or partial SG replacement. Although replacement costs canmore » range upward of $100-million, this step restores full-power operation, simplifies inspection, shortens subsequent outages, increases unit availability, and reduces radiation exposure of maintenance personnel. Taken together, these can lead to economies over the long term.« less

  3. High Temporal Resolution Tropospheric Wind Profile Observations at NASA Kennedy Space Center During Hurricane Irma

    NASA Technical Reports Server (NTRS)

    Decker, Ryan; Barbre, Robert; Huddleston, Lisa; Wilfong, Tim; Brauer, Tom

    2018-01-01

    The NASA Kennedy Space Center (KSC) operates a 48-MHz Tropospheric/Stratospheric Doppler Radar Wind Profiler (TDRWP) on a continual basis generating wind profiles between 2-19 km in the support of space launch vehicle operations. A benefit of the continual operability of the system is the ability to provide unique observations of severe weather events such as hurricanes. On the evening of 10 September 2017, Hurricane Irma passed within 100 miles to the west of KSC through the middle of the Florida peninsula. The hurricane was responsible for power outages to approximately 2/3 of Florida's population. This paper will describe the characteristics of the tropospheric wind observations from the TDRWP during Irma, provide a comparison to previous TDRWP observations from Hurricane Matthew in 2016, and discuss lessons learned regarding dissemination of TDRWP data during the event.

  4. Compact first and second order polarization mode dispersion emulator

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Li, Shiguang; Yang, Changxi

    2005-08-01

    We propose a 1st and 2nd order polarization mode dispersion emulator (PMDE) with one variable differential group delay (DGD) element using birefringence crystals and four polarization controllers (PCs). Monte Carlo simulations demonstrate that the output 1st and 2nd order polarization mode dispersion (PMD) generated by the PMDE consists with statistic theory. Compared with former PMDEs, this design is tunable, lower-cost, and more integrated for fabrication, which shows response time of 150 ?s, response frequency of 3.8 kHz, working wavelength of 1550 nm, total power consumption of less than 3 W, working range of 0---84 ps and 0---3600 ps2 for 1st and 2nd order PMD emulation, respectively. Also, it is programmable and can be controlled by either singlechip or computer. It can be applied to study the outage probability of optical communication systems due to PMD effect and the effectiveness of PMD compensation.

  5. Hurricane Sandy: Shared Trauma and Therapist Self-Disclosure.

    PubMed

    Rao, Nyapati; Mehra, Ashwin

    2015-01-01

    Hurricane Sandy was one of the most devastating storms to hit the United States in history. The impact of the hurricane included power outages, flooding in the New York City subway system and East River tunnels, disrupted communications, acute shortages of gasoline and food, and a death toll of 113 people. In addition, thousands of residences and businesses in New Jersey and New York were destroyed. This article chronicles the first author's personal and professional experiences as a survivor of the hurricane, more specifically in the dual roles of provider and trauma victim, involving informed self-disclosure with a patient who was also a victim of the hurricane. The general analytic framework of therapy is evaluated in the context of the shared trauma faced by patient and provider alike in the face of the hurricane, leading to important implications for future work on resilience and recovery for both the therapist and patient.

  6. Assessment of GPS carrier-phase stability for time-transfer applications.

    PubMed

    Larson, K M; Levine, J; Nelson, L M; Parker, T E

    2000-01-01

    We have conducted global positioning system (GPS) carrier-phase time-transfer experiments between the master clock (MC) at the U.S. Naval Observatory (USNO) in Washington, DC and the alternate master clock (AMC) at Schriever Air Force Base near Colorado Springs, Colorado. These clocks are also monitored on an hourly basis with two-way satellite time-transfer (TWSTT) measurements. We compared the performance of the GPS carrier phase and TWSTT systems over a 236-d period. Because of power problems and data outages during the carrier-phase experiment, the longest continuous time span is 96 d. The data from this period show agreement with TWSTT within +/-1 ns, apart from an overall constant time offset (caused by unknown delays in the GPS hardware at both ends). For averaging times of a day, the carrier-phase and TWSTT systems have a frequency uncertainty of 2.5 and 5.5 parts in 10(15), respectively.

  7. Plant maintenance and advanced reactors, 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agnihotri, Newal

    2005-09-15

    The focus of the September-October issue is on plant maintenance and advanced reactors. Major articles/reports in this issue include: First U.S. EPRs in 2015, by Ray Ganthner, Framatome ANP; Pursuing several opportunities, by William E. (Ed) Cummins, Westinghouse Electric Company; Vigorous plans to develop advanced reactors, by Yuliang Sun, Tsinghua University, China; Multiple designs, small and large, by Kumiaki Moriya, Hitachi Ltd., Japan; Sealed and embedded for safety and security, by Handa Norihiko, Toshiba Corporation, Japan; Scheduled online in 2010, by Johan Slabber, PMBR (Pty) Ltd., South Africa; Multi-application reactors, by Nikolay G. Kodochigov, OKBM, Russia; Six projects under budgetmore » and on schedule, by David F. Togerson, AECL, Canada; Creating a positive image, by Scott Peterson, Nuclear Energy Institute (NEI); Advanced plans for nuclear power's renaissance, by John Cleveland, International Atomic Energy Agency, Austria; and, Plant profile: last five outages in less than 20 days, by Beth Rapczynski, Exelon Nuclear.« less

  8. Multi-agent electricity market modeling with EMCAS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    North, M.; Macal, C.; Conzelmann, G.

    2002-09-05

    Electricity systems are a central component of modern economies. Many electricity markets are transitioning from centrally regulated systems to decentralized markets. Furthermore, several electricity markets that have recently undergone this transition have exhibited extremely unsatisfactory results, most notably in California. These high stakes transformations require the introduction of largely untested regulatory structures. Suitable tools that can be used to test these regulatory structures before they are applied to real systems are required. Multi-agent models can provide such tools. To better understand the requirements such as tool, a live electricity market simulation was created. This experience helped to shape the developmentmore » of the multi-agent Electricity Market Complex Adaptive Systems (EMCAS) model. To explore EMCAS' potential, several variations of the live simulation were created. These variations probed the possible effects of changing power plant outages and price setting rules on electricity market prices.« less

  9. Task related doses in Spanish pressurized water reactors over the period 1988-1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Donnell, P.; Labarta, T.; Amor, I.

    1995-03-01

    In order to evaluate in depth the collective dose trend and its correlation with the effectiveness of the practical application of the ALARA principle in Spanish nuclear facilities, and base the different policy lines to promote this criteria, the CSN has fullfilled an analysis of the task related doses data over the period 1988-1992. Previously, the CSN had required to the utilities the compilation of their refuelling outage collective dose from 1988 according with a predeterminate number of tasks, in order to have available a representative and retrospective set of data in an homogeneous way and coherent with the internationalmore » data banks on occupational exposure in NPP, as the CEC and the NEA ones. The scope of this analysis was the following: first, the collective dose summaries for outage tasks and departments for PWR and for BWR, including the minimum, maximum and average dose (and statistics data) for 18 different refuelling outage tasks and 12 personal departments for each generation of each type of rector, the task and department related collective dose trends in each plant and in each generation, and second, the dose reduction techniques having been used during that period in each plant and the relative level of adoption. In this presentation the main results and conclusions of the first part of the study are reviewed for PWR.« less

  10. The optical communication link outage probability in satellite formation flying

    NASA Astrophysics Data System (ADS)

    Arnon, Shlomi; Gill, Eberhard

    2014-02-01

    In recent years, several space systems consisting of multiple satellites flying in close formation have been proposed for various purposes such as interferometric synthetic aperture radar measurement (TerraSAR-X and the TanDEM-X), detecting extra-solar earth-like planets (Terrestrial Planet Finder-TPF and Darwin), and demonstrating distributed space systems (DARPA F6 project). Another important purpose, which is the concern of this paper, is for improving radio frequency communication to mobile terrestrial and maritime subscribers. In this case, radio frequency signals from several satellites coherently combine such that the received/transmit signal strength is increased proportionally with the number of satellites in the formation. This increase in signal strength allows to enhance the communication data rate and/or to reduce energy consumption and the antenna size of terrestrial mobile users' equipment. However, a coherent combination of signals without aligning the phases of the individual communication signals interrupts the communication and outage link between the satellites and the user. The accuracy of the phase estimation is a function of the inter-satellite laser ranging system performance. This paper derives an outage probability model of a coherent combination communication system as a function of the pointing vibration and jitter statistics of an inter-satellite laser ranging system tool. The coherent combination probability model, which could be used to improve the communication to mobile subscribers in air, sea and ground is the main importance of this work.

  11. Metallurgical evaluation of a feedwater nozzle to safe-end weld

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowerman, B.S.; Czajkowski, C.J.; Roberts, T.C.

    1999-11-01

    Weld cracks in safety class systems are a serious concern, because these systems are part of the primary barrier providing containment of radioactive coolant. Loss of weld integrity yields leaks, or, under catastrophic failure, can be the basis for a severe loss of coolant accident. A circumferential indication was found by ultrasonic examination (UT) in the N4A-2 inlet feedwater nozzle to safe-end weld during the second refueling outage of River Bend Station Unit 1 in March 1989. The indication, approximately 15cm (6in) long with a reported maximum depth of 0.5cm (0.1in), was located in the Alloy 182 weld butter onmore » the safe-end side of the weld. (The safe-end base metal was ASME SA 508 Class 1 carbon steel.) The reported characteristics of the UT indication were indicative of intergranular stress corrosion cracking. This indication was reexamined during the second and third fuel cycles in March 1990 and September 1991, respectively, and during the third refuel outage in November 1990. Crack growth was reported during each examination. The safe-end was replaced during the fourth refueling outage in the summer of 1992. The US Nuclear Regulatory Commission (NRC) subsequently contracted with Brookhaven National laboratory (BNL) to conduct a confirmatory investigation to establish the failure mode and determine the root causes of cracking in the safe-end weld.« less

  12. Disruption avoidance by means of electron cyclotron waves

    NASA Astrophysics Data System (ADS)

    Esposito, B.; Granucci, G.; Maraschek, M.; Nowak, S.; Lazzaro, E.; Giannone, L.; Gude, A.; Igochine, V.; McDermott, R.; Poli, E.; Reich, M.; Sommer, F.; Stober, J.; Suttrop, W.; Treutterer, W.; Zohm, H.; ASDEX Upgrade, the; FTU Teams

    2011-12-01

    Disruptions are very challenging to ITER operation as they may cause damage to plasma facing components due to direct plasma heating, forces on structural components due to halo and eddy currents and the production of runaway electrons. Electron cyclotron (EC) waves have been demonstrated as a tool for disruption avoidance by a large set of recent experiments performed in ASDEX Upgrade and FTU using various disruption types, plasma operating scenarios and power deposition locations. The technique is based on the stabilization of magnetohydrodynamic (MHD) modes (mainly m/n = 2/1) through the localized injection of EC power on the resonant surface. This paper presents new results obtained in ASDEX Upgrade regarding stable operation above the Greenwald density achieved after avoidance of density limit disruptions by means of ECRH and suitable density feedback control (L-mode ohmic plasmas, Ip = 0.6 MA, Bt = 2.5 T) and NTM-driven disruptions at high-β limit delayed/avoided by means of both co-current drive (co-ECCD) and pure heating (ECRH) with power <=1.7 MW (H-mode NBI-heated plasmas, PNBI ~ 7.5 MW, Ip = 1 MA, Bt = 2.1 T, q95 ~ 3.6). The localized perpendicular injection of ECRH/ECCD onto a resonant surface leads to the delay and/or complete avoidance of disruptions. The experiments indicate the existence of a power threshold for mode stabilization to occur. An analysis of the MHD mode evolution using the generalized Rutherford equation coupled to the frequency and phase evolution equations shows that control of the modes is due to EC heating close to the resonant surface. The ECRH contribution (Δ'H term) is larger than the co-ECCD one in the initial and more important phase when the discharge is 'saved'. Future research and developments of the disruption avoidance technique are also discussed.

  13. Experimental Verification and Integration of a Next Generation Smart Power Management System

    NASA Astrophysics Data System (ADS)

    Clemmer, Tavis B.

    With the increase in energy demand by the residential community in this country and the diminishing fossil fuel resources being used for electric energy production there is a need for a system to efficiently manage power within a residence. The Smart Green Power Node (SGPN) is a next generation energy management system that automates on-site energy production, storage, consumption, and grid usage to yield the most savings for both the utility and the consumer. Such a system automatically manages on-site distributed generation sources such as a PhotoVoltaic (PV) input and battery storage to curtail grid energy usage when the price is high. The SGPN high level control features an advanced modular algorithm that incorporates weather data for projected PV generation, battery health monitoring algorithms, user preferences for load prioritization within the home in case of an outage, Time of Use (ToU) grid power pricing, and status of on-site resources to intelligently schedule and manage power flow between the grid, loads, and the on-site resources. The SGPN has a scalable, modular architecture such that it can be customized for user specific applications. This drove the topology for the SGPN which connects on-site resources at a low voltage DC microbus; a two stage bi-directional inverter/rectifier then couples the AC load and residential grid connect to on-site generation. The SGPN has been designed, built, and is undergoing testing. Hardware test results obtained are consistent with the design goals set and indicate that the SGPN is a viable system with recommended changes and future work.

  14. Boiling water reactor radiation shielded Control Rod Drive Housing Supports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baversten, B.; Linden, M.J.

    1995-03-01

    The Control Rod Drive (CRD) mechanisms are located in the area below the reactor vessel in a Boiling Water Reactor (BWR). Specifically, these CRDs are located between the bottom of the reactor vessel and above an interlocking structure of steel bars and rods, herein identified as CRD Housing Supports. The CRD Housing Supports are designed to limit the travel of a Control Rod and Control Rod Drive in the event that the CRD vessel attachement went to fail, allowing the CRD to be ejected from the vessel. By limiting the travel of the ejected CRD, the supports prevent a nuclearmore » overpower excursion that could occur as a result of the ejected CRD. The Housing Support structure must be disassembled in order to remove CRDs for replacement or maintenance. The disassembly task can require a significant amount of outage time and personnel radiation exposure dependent on the number and location of the CRDs to be changed out. This paper presents a way to minimize personal radiation exposure through the re-design of the Housing Support structure. The following paragraphs also delineate a method of avoiding the awkward, manual, handling of the structure under the reactor vessel during a CRD change out.« less

  15. Global Precipitation Measurement (GPM) Orbit Design and Autonomous Maneuvers

    NASA Technical Reports Server (NTRS)

    Folta, David; Mendelsohn, Chad

    2003-01-01

    The NASA Goddard Space Flight Center's Global Precipitation Measurement (GPM) mission will meet a challenge of measuring worldwide precipitation every three hours. The GPM spacecraft, part of a constellation, will be required to maintain a circular orbit in a high drag environment to accomplish this challenge. Analysis by the Flight Dynamics Analysis Branch has shown that the prime orbit altitude of 40% is necessary to prevent ground track repeating. Combined with goals to minimize maneuver impacts to science data collection and enabling reasonable long-term orbit predictions, the GPM project has decided to fly an autonomous maneuver system. This system is a derivative of the successful New Millennium Program technology flown onboard the Earth Observing-1 mission. This paper presents the driving science requirements and goals of the mission and shows how they will be met. Analysis of the orbit optimization and the AV requirements for several ballistic properties are presented. The architecture of the autonomous maneuvering system to meet the goals and requirements is presented along with simulations using a GPM prototype. Additionally, the use of the GPM autonomous system to mitigate possible collision avoidance and to aid other spacecraft systems during navigation outages is explored.

  16. Assessment of 69 kV Underground Cable Thermal Ratings using Distributed Temperature Sensing

    NASA Astrophysics Data System (ADS)

    Stowers, Travis

    Underground transmission cables in power systems are less likely to experience electrical faults, however, resulting outage times are much greater in the event that a failure does occur. Unlike overhead lines, underground cables are not self-healing from flashover events. The faulted section must be located and repaired before the line can be put back into service. Since this will often require excavation of the underground duct bank, the procedure to repair the faulted section is both costly and time consuming. These added complications are the prime motivators for developing accurate and reliable ratings for underground cable circuits. This work will review the methods by which power ratings, or ampacity, for underground cables are determined and then evaluate those ratings by making comparison with measured data taken from an underground 69 kV cable, which is part of the Salt River Project (SRP) power subtransmission system. The process of acquiring, installing, and commissioning the temperature monitoring system is covered in detail as well. The collected data are also used to evaluate typical assumptions made when determining underground cable ratings such as cable hot-spot location and ambient temperatures. Analysis results show that the commonly made assumption that the deepest portion of an underground power cable installation will be the hot-spot location does not always hold true. It is shown that distributed cable temperature measurements can be used to locate the proper line segment to be used for cable ampacity calculations.

  17. [Work accidents and automatic circuit reclosers in the electricity sector: beyond the immediate causes].

    PubMed

    Silva, Alessandro Jose Nunes da; Almeida, Ildeberto Muniz de; Vilela, Rodolfo Andrade de Gouveia; Mendes, Renata Wey Berti; Hurtado, Sandra Lorena Beltran

    2018-05-10

    The Brazilian electricity sector has recorded high work-related mortality rates that have been associated with outsourcing, used to cut costs. In order to decrease the power outage time for consumers, the industry adopted the automatic circuit recloser as the technical solution. The device has hazardous implications for maintenance workers. The aim of this study was to analyze the origins and consequences of work accidents in power systems with automatic circuit recloser, using the Accident Analysis and Prevention (AAP) model. The AAP model was used to investigate two work accidents, aimed to explore the events' organizational origins. Case 1 - when changing a deenergized secondary line, a worker received a shock from the energized primary cable (13.8kV). The system reclosed three times, causing severe injury to the worker (amputation of a lower limb). Case 2 - a fatal work accident occurred during installation of a new crosshead on a partially insulated energized line. The tip of a metal cross arm section strap touched the energized secondary line and electrocuted the maintenance operator. The circuit breaker component of the automatic circuit recloser failed. The analyses revealed how business management logic can participate in the root causes of work accidents through failures in maintenance management, outsourced workforce management, and especially safety management in systems with reclosers. Decisions to adopt automation to guarantee power distribution should not overlook the risks to workers in overhead power lines or fail to acknowledge the importance of ensuring safe conditions.

  18. Concepts for 18/30 GHz satellite communication system study. Executive summary

    NASA Technical Reports Server (NTRS)

    Baker, M.; Davies, R.; Cuccia, L.; Mitchell, C.

    1979-01-01

    An examination of a multiplicity of interconnected parameters ranging from specific technology details to total system economic costs for satellite communication systems at the 18/30 GHz transmission bands are presented. It was determined that K sub A band systems can incur a small communications outage during very heavy rainfall periods and that reducing the outage to zero would lead to prohibitive system costs. On the other hand, the economics of scale, ie, one spacecraft accommodating 2.5 GHz of bandwidth coupled with multiple beam frequency reuse, leads to very low costs for those users who can tolerate the 5 to 50 hours per year of downtime. A multiple frequency band satellite network can provide the ultimate optimized match to the consumer performance/economics demands.

  19. Fort Leonard Wood German POW Stonework: Maintenance and Repair

    DTIC Science & Technology

    2017-07-01

    powered chisels, scaler (power chipper), and thin diamond- bladed grinders should be approved by architect or project manager. All work should be...Figure 5. Deteriorated mortar and plant growth on the patio of Garlington House. Photo NCPTT 8 • Raising mower blades to avoid low-ly- ing features...protective perimeter around features, attaching protective bumpers to the lawn mower, raising mower blades to avoid low-lying features, and using smaller

  20. Development of an integrated staircase lift for home access.

    PubMed

    Mattie, Johanne L; Borisoff, Jaimie F; Leland, Danny; Miller, William C

    2015-12-01

    Stairways into buildings present a significant environmental barrier for those with mobility impairments, including older adults. A number of home access solutions that allow users to safely enter and exit the home exist, however these all have some limitations. The purpose of this work was to develop a novel, inclusive home access solution that integrates a staircase and a lift into one device. The development of an integrated staircase lift followed a structured protocol with stakeholders providing feedback at various stages in the design process, consistent with rehabilitation engineering design methods. A novel home access device was developed. The integrated staircase-lift has the following features: inclusivity, by a universal design that provides an option for either use of stairs or a lift; constant availability, with a lift platform always ready for use on either level; and potential aesthetic advantages when integrating the device into an existing home. The potential also exists for emergency descent during a power outage, and self-powered versions. By engaging stakeholders in a user centred design process, insight on the limitations of existing home access solutions and specific feedback on our design guided development of a novel home access device.

Top