Sample records for axial pattern flap

  1. Near-Infrared Irradiation Increases Length of Axial Pattern Flap Survival in Rats.

    PubMed

    Yasunaga, Yoshichika; Matsuo, Kiyoshi; Tanaka, Yohei; Yuzuriha, Shunsuke

    2017-01-01

    Objective: We previously reported that near-infrared irradiation nonthermally induces long-lasting vasodilation of the subdermal plexus by causing apoptosis of vascular smooth muscle cells. To clarify the possible application of near-infrared irradiation to prevent skin flap necrosis, we evaluated the length of axial pattern flap survival in rats by near-infrared irradiation. Methods: A bilaterally symmetric island skin flap was elevated under the panniculus carnosus on the rat dorsum. Half of the flap was subjected to near-infrared irradiation just before flap elevation with a device that simulates solar radiation, which has a specialized contact cooling apparatus to avoid thermal effects. The length of flap survival of the near-infrared irradiated side was measured 7 days after flap elevation and compared with the nonirradiated side. Results: The irradiated side showed elongation of flap survival compared with the nonirradiated side (73.3 ± 11.7 mm vs 67.3 ± 14.9 mm, respectively, P = .03). Conclusions: Near-infrared irradiation increases the survival length of axial pattern flaps in rats.

  2. Versatility of the Angularis Oris Axial Pattern Flap for Facial Reconstruction.

    PubMed

    Losinski, Sara L; Stanley, Bryden J; Schallberger, Sandra P; Nelson, Laura L; Towle Millard, Heather A M

    2015-11-01

    To describe the versatility of the axial pattern flap based on the cutaneous perforating branch of the angularis oris artery for reconstruction of large facial defects in dogs, including complications and clinical outcomes. Retrospective clinical case series. Client-owned dogs (n = 8). Facial flaps (n = 9) based at the commissure of the lip with a caudodorsal orientation were utilized, with established anatomical borders. Flaps were elevated deep to the panniculus carnosus in a caudal to rostral direction, preserving the angularis oris artery, its cutaneous perforator, and surrounding cutaneous vasculature. Flaps were rotated dorsally or ventrally to cover the defect. Primary closure of the donor site was by direct apposition in all cases. Angularis oris axial pattern flaps were most commonly used to close large defects of the nasomaxillary area rostral to the eyes (6 dogs), followed by orbital (2) and intermandibular (1) defects. Defects occurred because of tumor resection (6 dogs), trauma (2), and a chronic, non-healing wounding (1). All flaps healed with acceptable functional and cosmetic outcomes without major complications. Followup ranged from 10 days to 16 months. Minor postoperative complications included flap edema (8 dogs), partial incisional dehiscence (3), distal tip necrosis (2), and oroantral fistula recurrence (1). Angularis oris axial pattern flaps provided hirsute, full-thickness skin coverage of a variety of large facial defects with minor complications, and should be considered when restructuring large defects of the rostral face or chin. © Copyright 2015 by The American College of Veterinary Surgeons.

  3. Central hemimaxillectomy and reconstruction using a superficial temporal artery axial pattern flap in a domestic short hair cat.

    PubMed

    Lester, S; Pratschke, K

    2003-08-01

    A 2-year-old, neutered male domestic short hair cat presented with a large mass involving the right upper lip and underlying gingiva. A previous attempt at mass excision had failed, and the histopathological diagnosis was reported to be a fibrosarcoma. The cat was otherwise in good health.A central hemimaxillectomy was performed with extensive soft-tissue dissection and maxillofacial reconstruction achieved using an axial pattern flap based on the superficial temporal artery. This is the first reported clinical case of the use of the superficial temporal artery axial pattern flap in the cat. Histopathology identified a periodontal fibromatous epulis.

  4. Use of a caudal auricular axial pattern flap in three cats and one dog following orbital exenteration.

    PubMed

    Stiles, Jean; Townsend, Wendy; Willis, Michelle; Moore, Phillip A; Smith, Eric

    2003-06-01

    Orbital exenteration accompanied by wide eyelid excision in the cat and dog may leave a defect that cannot be closed in a primary fashion. This report describes the use of a caudal auricular axial pattern flap to effect closure following orbital exenteration in three cats and one dog. The most common complication was distal flap necrosis, which necessitated a second surgery in two patients.

  5. Quantitative analysis of skin flap blood flow in the rat using laser Doppler velocimetry.

    PubMed Central

    Marks, N J

    1985-01-01

    Two experiments carried out on rat skin flaps are described, where microvascular flow has been measured noninvasively by a laser Doppler velocimeter. Using this technique it is possible to define the limits of an axial pattern flap in terms of microvascular flow; this was found to increase when the flap is elevated. 'Random-pattern' perfusion is defined by a fall in flow. This recovers sequentially along the flap, and at a constant rate at all sites. A differential in microvascular perfusion is thus maintained along a random-pattern flap for at least the first postoperative week. In a second experiment it is shown that there appears to be a linear relationship between the reduction in skin blood flow in a random-pattern flap and the distance from the base at which the measurements are made. It is suggested that these data support the view that the blood flow in a skin flap recovers primarily from its base rather than via peripheral neovascularization, and that this is due to vascular collaterals opening within the flap rather than to a relaxation of sympathetic tone. PMID:3156992

  6. [Anatomical study and clinical application of a leg flap pedicle-included with cutaneous nerve and its concomitant vessels].

    PubMed

    Liu, B; Hao, X; Goan, M

    2000-05-01

    To investigate the blood supply patterns and the clinical liability of a leg flap pedicle-included with cutaneous nerve and its concomitant vessels. Fresh cadaver legs with thirty-two in infants and two in adults were anatomically examined after the intravenous injection of the red Chlorinated Poly Vingl Choride (CPVC). Five patients with the soft tissue defects were selected for the treatment with the flap pedicle-included with the cutaneous nerve and its concomitant vessels. Four main cutaneous nerves were found in the leg after they perforated the deep fascia out. They were companioned with their concomitant vessels with different blood-supply pateeerns, which the upper part of the leg was in an axial pattern and the lower part was in a "chain-type anastomosing" pattern. Following the above-mentioned findings, five cases were successfully treated with this led flap. The leg flap should be designed along the cutaneous nerve and its concomitant vessels. When the flap is applied in the area of blood supply with "chain-type anastomosing" pattern, the deep fascia should also be included in the flap.

  7. Propeller Perforator Flaps in Distal Lower Leg: Evolution and Clinical Applications

    PubMed Central

    2012-01-01

    Simple or complex defects in the lower leg, and especially in its distal third, continue to be a challenging task for reconstructive surgeons. A variety of flaps were used in the attempt to achieve excellence in form and function. After a long evolution of the reconstructive methods, including random pattern flaps, axial pattern flaps, musculocutaneous flaps and fasciocutaneous flaps, the reappraisal of the works of Manchot and Salmon by Taylor and Palmer opened the era of perforator flaps. This era began in 1989, when Koshima and Soeda, and separately Kroll and Rosenfield described the first applications of such flaps. Perforator flaps, whether free or pedicled, gained a high popularity due to their main advantages: decreasing donor-site morbidity and improving aesthetic outcome. The use as local perforator flaps in lower leg was possible due to a better understanding of the cutaneous circulation, leg vascular anatomy, angiosome and perforasome concepts, as well as innovations in flaps design. This review will describe the evolution, anatomy, flap design, and technique of the main distally pedicled propeller perforator flaps used in the reconstruction of defects in the distal third of the lower leg and foot. PMID:22783507

  8. Experimental study on axial pedicled composite flap prefabrication with high density porous polyethylene implants: medporocutaneous flap.

    PubMed

    Kocman, A Emre; Kose, Aydan A; Karabagli, Yakup; Baycu, Cengiz; Cetin, Cengiz

    2008-01-01

    Composite flaps including soft tissues with bone or cartilage are widely used in reconstruction of three-dimensional defects, but have some disadvantages. Flap prefabrication with alloplastic implants is an alternative procedure. Axial pattern vascularised high density porous polyethylene (HDPP) implants are capable of sustaining skin grafts. The purpose of this study was to examine the vascularisation pattern of the skin island in a composite flap prefabrication model prepared with vascularised HDPP implants. Forty male Wistar rats divided into four groups were used. A 9.5 x 6 x 2 mm HDPP block was centered on the dissected saphenous pedicle and anchored under the abdominal skin in the experimental group I (n=10). In experimental group II (n=10) saphenous artery and vein were put between the skin and the implant. Thus, the structures were laid as skin, HDPP block, pedicle in experimental group I and skin, pedicle, HDPP block in experimental group II. HDPP block-implanted and pedicle-implanted only groups served as control groups I and II, respectively. Eight weeks after prefabrication, skin islands 1.5 x 5 cm in size incorporated with implants were elevated based on saphenous vessels in the experimental groups and skin islands only based on the pedicle in control group II. Skin islands of the same dimensions were raised as grafts in control group I. Nylon sheets were put under the flaps and grafts to prevent vascularisation from the recipient bed. Flap viability was assessed by measuring the surface area on the 7th day. Total necrosis developed in composite grafts of control group I. Flap survival was higher in experimental group II and control group II (45% and 46.8%) than in group I (29.28%). Histologic studies demonstrated fibrovascular ingrowth into the HDPP implants, except in control group I, with significant inflammatory response and necrosis. Vascularisation of skin and implants from the pedicle was seen also microangiographically. In conclusion, a composite flap prefabrication model including vascularised HDPP implant, skin and vascular carrier was developed. This new flap was termed a 'medporocutaneous flap'.

  9. A new mucosal propeller flap (deep lingual artery axial propeller): the renaissance of lingual flaps.

    PubMed

    Cordova, Adriana; Toia, Francesca; D'Arpa, Salvatore; Giunta, Gabriele; Moschella, Francesco

    2015-03-01

    Lingual flaps provide ideal mucosal coverage for intraoral defects but traditionally require two surgical stages. The authors present an axial mucosal propeller flap for single-stage intraoral reconstruction. The flap includes the mucosa of the lateral side of the tongue, islanded on the deep lingual vessels. Between 2011 and 2013, 23 patients underwent intraoral mucosal reconstruction with a deep lingual artery axial propeller flap after cancer resection in the cheek (n = 16), floor of the mouth (n = 2), retromolar trigone (n = 2), hard palate (n = 2), and soft palate (n = 1). Mean defect size was 19.5 cm. Preoperative and postoperative intraoral function was evaluated with the Functional Intraoral Glasgow Scale. The authors always achieved one-stage reconstruction with primary donor-site closure. The only complications were an infection treated conservatively and a late oronasal fistula caused by radiotherapy. All patients resumed an oral diet after 1 week and none required surgical revision. Mean 12-month postoperative Functional Intraoral Glasgow Scale score was better than the preoperative score (13.5 versus 12.8). The deep lingual artery axial propeller flap combines the advantages of the traditional lingual flap (i.e., reliable axial vascularization and like-with-like reconstruction) with those of a propeller flap (i.e., one-stage transfer of like tissue and extreme mobility) and has wider indications than a conventional lingual flap. The technique is fast and has low morbidity and good functional results, and the authors recommend it as a first-choice technique to reconstruct moderate to large intraoral defects. Therapeutic, IV.

  10. Radical lateral body-wall resection for fibrosarcoma with reconstruction using polypropylene mesh and a caudal superficial epigastric axial pattern flap: a prospective clinical study of the technique and results in 6 cats.

    PubMed

    Lidbetter, David A; Williams, Fred A; Krahwinkel, D J; Adams, William H

    2002-01-01

    To describe and evaluate a technique for radical resection of the lateral body wall for treatment of fibrosarcoma with reconstruction using polypropylene mesh and a caudal superficial epigastric axial pattern flap in cats. Prospective, clinical study. Six client-owned cats with fibrosarcoma. Six cats with histologically confirmed fibrosarcoma of the lateral body wall were staged using radiography and/or computer tomography scanning. Preoperative radiotherapy was used in 3 cats. All cats had the lateral abdominal wall resected and reconstructed with polypropylene mesh. A caudal superficial epigastric flap was mobilized and rotated to close the skin deficit. The animals were evaluated after surgery for wound complications, tumor recurrence, and metastasis. Outcome was assessed by patient examination and client consultation. Minor dehiscence of the skin flaps occurred in 2 cats, and 1 other cat was successfully resuscitated from respiratory and cardiac arrest after surgery. All tissue specimens were tumor-free at the surgical margins. Follow-up times ranged from 12 to 21 months, with a mean time of 17.2 months. None of the cats had evidence of local tumor recurrence or metastasis; outcome was judged good to excellent in all cats. Radical lateral body-wall resection and reconstruction is an effective technique for achieving local tumor control with acceptable patient morbidity. Further studies are needed to assess whether the technique will result in improved tumor-free intervals and survival times. Copyright 2002 by The American College of Veterinary Surgeons

  11. The figure-of-eight radix nasi flap for medial canthal defects.

    PubMed

    Seyhan, Tamer

    2010-09-01

    Basal cell carcinomas commonly involve the medial canthal region and reconstruction of medial canthal defects is a challenging problem in reconstructive surgery. A new axial pattern flap raised from radix nasi region has been successfully used for the medial canthal defects in eight patients in figure-of-eight manner. One of the ellipses of the figure of eight is the defect, the other is the radix nasi flap. The radix nasi flap with a dimension up to 25 mm is transposed to the defect based either on ipsilateral anastomosis of the dorsal nasal artery with angular artery (AA) or with the connection of its source artery (i.e. ophthalmic artery) if the AA is damaged. All flaps survived and no tumour recurrence was observed. The donor sites were closed primarily and hidden at the radix nasi crease in all cases. The radix nasi flap in figure-of-eight fashion is good alternative for defects of the medial canthal area in terms of attaining a suitable colour and texture and minimal surgical scars. Copyright 2009 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  12. "Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.

    PubMed

    Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng

    2008-12-01

    Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.

  13. Force Generation by Flapping Foils

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, P. R.; Donnelly, M.

    1996-11-01

    Aquatic animals like fish use flapping caudal fins to produce axial and cross-stream forces. During WW2, German scientists had built and tested an underwater vehicle powered by similar flapping foils. We have examined the forces produced by a pair of flapping foils. We have examined the forced produced by a pair of flapping foils attached to the tail end of a small axisymmetric cylinder. The foils operate in-phase (called waving), or in anti-phase (called clapping). In a low-speed water tunnel, we have undertaken time-dependent measurements of axial and cross-stream forces and moments that are exerted by the vortex shedding process over the entire body. Phase-matched LDV measurements of vorticity-velocity vectors, as well as limited flow visualization of the periodic vortex shedding process have also been carried out. The direction of the induced velocity within a pair of shed vortices determines the nature of the forces produced, viz., thrust or drag or cross-stream forces. The clapping mode produces a widely dispersed symmetric array of vortices which results in axial forces only (thrust and rag). On the other hand, the vortex array is staggered in the waving mode and cross-stream (maneuvering) forces are then generated.

  14. Dipteran wing motor-inspired flapping flight versatility and effectiveness enhancement

    PubMed Central

    Harne, R. L.; Wang, K. W.

    2015-01-01

    Insects are a prime source of inspiration towards the development of small-scale, engineered, flapping wing flight systems. To help interpret the possible energy transformation strategies observed in Diptera as inspiration for mechanical flapping flight systems, we revisit the perspective of the dipteran wing motor as a bistable click mechanism and take a new, and more flexible, outlook to the architectural composition previously considered. Using a representative structural model alongside biological insights and cues from nonlinear dynamics, our analyses and experimental results reveal that a flight mechanism able to adjust motor axial support stiffness and compression characteristics may dramatically modulate the amplitude range and type of wing stroke dynamics achievable. This corresponds to significantly more versatile aerodynamic force generation without otherwise changing flapping frequency or driving force amplitude. Whether monostable or bistable, the axial stiffness is key to enhance compressed motor load bearing ability and aerodynamic efficiency, particularly compared with uncompressed linear motors. These findings provide new foundation to guide future development of bioinspired, flapping wing mechanisms for micro air vehicle applications, and may be used to provide insight to the dipteran muscle-to-wing interface. PMID:25608517

  15. Experience with peroneus brevis muscle flaps for reconstruction of distal leg and ankle defects

    PubMed Central

    Bajantri, Babu; Bharathi, Ravindra; Ramkumar, Sanjai; Latheef, Latheesh; Dhane, Smitha; Sabapathy, S. Raja

    2013-01-01

    Objective: Peroneus brevis is a muscle in the leg which is expendable without much functional deficit. The objective of this study was to find out its usefulness in coverage of the defects of the lower leg and ankle. Patients and Methods: A retrospective analysis of the use of 39 pedicled peroneus brevis muscle flaps used for coverage of defects of the lower leg and ankle between November 2010 and December 2012 was carried out. The flaps were proximally based for defects of the lower third of the leg in 12 patients and distally based for reconstruction of defects of the ankle in 26 patients, with one patient having flaps on both ankles. Results: Partial flap loss in critical areas was found in four patients requiring further flap cover and in non-critical areas in two patients, which were managed with a skin graft. Three of the four critical losses occurred when we used it for covering defects over the medial malleolus. There was no complete flap loss in any of the patients. Conclusion: This flap has a unique vascular pattern and fails to fit into the classification of the vasculature of muscles by Mathes and Nahai. The unusual feature is an axial vessel system running down the deep aspect of the muscle and linking the perforators from the peroneal artery and anterior tibial artery, which allows it to be raised proximally or distally on a single perforator. The flap is simple to raise and safe for the reconstruction of small-to moderate-sized skin defects of the distal third of the tibia and all parts of the ankle except the medial malleolus, which is too far from the pedicle of the distally based flap. The donor site can be closed primarily to provide a linear scar. The muscle flap thins with time to provide a good result aesthetically at the primary defect. PMID:23960305

  16. Subcutaneous pedicle propeller flap: An old technique revisited and modified!

    PubMed Central

    Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash

    2016-01-01

    Background: Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. Methodology: This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Results: Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. Conclusion: The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap. PMID:27833285

  17. Subcutaneous pedicle propeller flap: An old technique revisited and modified!

    PubMed

    Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash

    2016-01-01

    Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap.

  18. Dipteran wing motor-inspired flapping flight versatility and effectiveness enhancement.

    PubMed

    Harne, R L; Wang, K W

    2015-03-06

    Insects are a prime source of inspiration towards the development of small-scale, engineered, flapping wing flight systems. To help interpret the possible energy transformation strategies observed in Diptera as inspiration for mechanical flapping flight systems, we revisit the perspective of the dipteran wing motor as a bistable click mechanism and take a new, and more flexible, outlook to the architectural composition previously considered. Using a representative structural model alongside biological insights and cues from nonlinear dynamics, our analyses and experimental results reveal that a flight mechanism able to adjust motor axial support stiffness and compression characteristics may dramatically modulate the amplitude range and type of wing stroke dynamics achievable. This corresponds to significantly more versatile aerodynamic force generation without otherwise changing flapping frequency or driving force amplitude. Whether monostable or bistable, the axial stiffness is key to enhance compressed motor load bearing ability and aerodynamic efficiency, particularly compared with uncompressed linear motors. These findings provide new foundation to guide future development of bioinspired, flapping wing mechanisms for micro air vehicle applications, and may be used to provide insight to the dipteran muscle-to-wing interface. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  19. Nonlinear flap-lag axial equations of a rotating beam

    NASA Technical Reports Server (NTRS)

    Kaza, K. R. V.; Kvaternik, R. G.

    1977-01-01

    It is possible to identify essentially four approaches by which analysts have established either the linear or nonlinear governing equations of motion for a particular problem related to the dynamics of rotating elastic bodies. The approaches include the effective applied load artifice in combination with a variational principle and the use of Newton's second law, written as D'Alembert's principle, applied to the deformed configuration. A third approach is a variational method in which nonlinear strain-displacement relations and a first-degree displacement field are used. The method introduced by Vigneron (1975) for deriving the linear flap-lag equations of a rotating beam constitutes the fourth approach. The reported investigation shows that all four approaches make use of the geometric nonlinear theory of elasticity. An alternative method for deriving the nonlinear coupled flap-lag-axial equations of motion is also discussed.

  20. The Arterialized Facial Artery Musculo-Mucosal Island Flap for Post-Oncological Tongue Reconstruction.

    PubMed

    Moro, Alessandro; Saponaro, Gianmarco; Doneddu, Piero; Cervelli, Daniele; Pelo, Sandro; Gasparini, Giulio; Garagiola, Umberto; D'Amato, Giuseppe; Todaro, Mattia

    2018-05-15

    In 1992, Pribaz described the facial artery musculomucosal flap (FAMM), an axial musculomucosal flap based on the facial artery. The FAMM flap, a modification of the nasolabial and buccal mucosal flaps, is widely used in the reconstruction of defects in the oral cavity. Many modifications of this flap have been described in the literature. Here we aimed to explore the use of an arterialized tunnelized FAMM island flap (a-FAMMIF) for the reconstruction tongue defects after tumor resection. From January 2015 to December 2016, five cases of tongue cancer were selected for the use of arterialized FAMMIF flap to reconstruct defects after tumor resection. Reconstruction was successful in all cases, except one case of total flap necrosis; partial necrosis of the flap occurred in two patients, which were solved with medications. The authors consider the a-FAMMIF an unreliable flap in the reconstruction of tongue defects.The authors recommend avoiding tunneling and island modification when the vein is not included in the pedicle.

  1. Botulinum toxin A and B raise blood flow and increase survival of critically ischemic skin flaps.

    PubMed

    Schweizer, Dennis F; Schweizer, Riccardo; Zhang, Shengye; Kamat, Pranitha; Contaldo, Claudio; Rieben, Robert; Eberli, Daniel; Giovanoli, Pietro; Erni, Dominique; Plock, Jan A

    2013-10-01

    Botulinum toxin (BTX) A and B are commonly used for aesthetic indications and in neuromuscular disorders. New concepts seek to prove efficacy of BTX for critical tissue perfusion. Our aim was to evaluate BTX A and B in a mouse model of critical flap ischemia for preoperative and intraoperative application. BTX A and B were applied on the vascular pedicle of an axial pattern flap in mice preoperatively or intraoperatively. Blood flow, tissue oxygenation, tissue metabolism, flap necrosis rate, apoptosis assay, and RhoA and eNOS expression were endpoints. Blood-flow measurements 1 d after the flap operation revealed a significant reduction to 53% in the control group, while flow was maintained or increased in all BTX groups (103%-129%). Over 5 d all BTX groups showed significant increase in blood flow to 166-187% (P < 0.01). Microdialysis revealed an increase of glucose and reduced lactate/pyruvate ratio and glycerol levels in the flap tissue of all BTX groups. This resulted in significantly improved tissue survival in all BTX groups compared with the control group (62% ± 10%; all P < 0.01): BTX A preconditioning (84% ± 5%), BTX A application intraoperatively (88% ± 4%), BTX B preconditioning (91% ± 4%), and intraoperative BTX B treatment (92% ± 5%). This was confirmed by TUNEL assay. Immunofluorescence demonstrated RhoA and eNOS expression in BTX groups. All BTX applications were similarly effective, despite pharmacologic dissimilarities and different timing. In conclusion, we were able to show on a vascular, tissue, cell, and molecular level that BTX injection to the feeding arteries supports flap survival through ameliorated blood flow and oxygen delivery. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Long-Term Follow-Up of Flap Prefabrication in Facial Reconstruction.

    PubMed

    Wang, Weixin; Zhao, Muxin; Tang, Yong; Chen, Wen; Yang, Zhe; Ma, Ning; Xu, Lisi; Feng, Jun; Li, Yangqun

    2017-07-01

    Flap prefabrication is to turn a random flap into an axial flap by transferring a vascular pedicle. In the past 13 years, we have prefabricated 20 flaps in 20 patients by the superficial temporal artery and its concomitant veins. Typically, a 50- to 800-mL tissue expander was implanted in the donor site. After flap maturation, the prefabricated flap was raised and transferred locally to cover the large defect on the face. All the cases were followed up regularly. The patients' age were between 3 and 27 years, the size of the flaps were between 3.5 × 5.5 cm and 13 × 15 cm, the superficial temporal artery length was between 10 and 15 cm. All flaps were transferred successfully: 10 of the flaps had venous congestion, partial epidermis exfoliation and flap necrosis occurred in 4 flaps. All cases were followed up for at least 1 year, the longest follow-up period was 9 years. Long-term follow-up results showed the prefabricated flap survived in good condition and had a satisfactory outcome. Because flap prefabrication is practical, and long-term follow-ups have proved its preferable characters and stability, it is a fine method for large area facial reconstructions.

  3. The radix nasi island flap: a versatile musculocutaneous flap for defects of the eyelids, nose, and malar region.

    PubMed

    Seyhan, Tamer

    2009-03-01

    A versatile musculocutan flap from the radix nasi region, the radix nasi island flap, is described. The flap has an axial blood supply derived from the dorsal nasal branch of the ophthalmic artery which is anastomosed to the terminal branch of the facial artery. The flap includes the skin, subcutaneous tissue, and procerus muscle. Ten patients, aged 50 to 86 years, have been reconstructed with this flap for defects in the nose (in 4 cases), midface (in 4 cases) and lower eyelids (in 2 cases). The mean flap size was 17 x 23 mm (range: 15 x 20 to 20 x 27 mm). All flaps fully survived. Additional complications and morbidity were not observed. The donor sites were closed a primarily closure in all cases. Follow-up ranged from 3 to 12 months (mean: 8.2 months). The radix nasi flap is a safe flap, has minimal donor site morbidity, and is especially suited for nasal and midface reconstruction in terms of attaining a suitable color and thickness.

  4. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    PubMed Central

    Kim, Jong Gyu

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839

  5. Flow separation on flapping and rotating profiles with spanwise gradients.

    PubMed

    Wong, J G; laBastide, B P; Rival, D E

    2017-02-15

    The growth of leading-edge vortices (LEV) on analogous flapping and rotating profiles has been investigated experimentally. Three time-varying cases were considered: a two-dimensional reference case with a spanwise-uniform angle-of-attack variation α; a case with increasing α towards the profile tip (similar to flapping flyers); and a case with increasing α towards the profile root (similar to rotor blades experiencing an axial gust). It has been shown that the time-varying spanwise angle-of-attack gradient produces a vorticity gradient, which, in combination with spanwise flow, results in a redistribution of circulation along the profile. Specifically, when replicating the angle-of-attack gradient characteristic of a rotor experiencing an axial gust, the spanwise-vorticity gradient is aligned such that circulation increases within the measurement domain. This in turn increases the local LEV growth rate, which is suggestive of force augmentation on the blade. Reversing the relative alignment of the spanwise-vorticity gradient and spanwise flow, thereby replicating that arrangement found in a flapping flyer, was found to reduce local circulation. From this, we can conclude that spanwise flow can be arranged to vary LEV growth to prolong lift augmentation and reduce the unsteadiness of cyclic loads.

  6. The "Tokyo" consensus on propeller flaps.

    PubMed

    Pignatti, Marco; Ogawa, Rei; Hallock, Geoffrey G; Mateev, Musa; Georgescu, Alexandru V; Balakrishnan, Govindasamy; Ono, Shimpei; Cubison, Tania C S; D'Arpa, Salvatore; Koshima, Isao; Hyakusoku, Hikko

    2011-02-01

    Over the past few years, the use of propeller flaps, which base their blood supply on subcutaneous tissue or isolated perforators, has become increasingly popular. Because no consensus has yet been reached on terminology and nomenclature of the propeller flap, different and confusing uses of the term can be found in the literature. In this article, the authors report the consensus on the definition and classification of propeller flaps reached by the authors that gathered at the First Tokyo Meeting on Perforator and Propeller Flaps in June of 2009. Some peculiar aspects of the surgical technique are discussed. A propeller flap can be defined as an "island flap that reaches the recipient site through an axial rotation." The classification is based on the nourishing pedicle (subcutaneous pedicled propeller flap, perforator pedicled propeller flap, supercharged propeller flap), the degrees of skin island rotation (90 to 180 degrees) and, when possible, the artery of origin of the perforator. The propeller flap is a useful reconstructive tool that can achieve good cosmetic and functional results. A flap should be called a propeller flap only if it fulfils the definition above. The type of nourishing pedicle, the source vessel (when known), and the degree of skin island rotation should be specified for each flap.

  7. Propeller flaps in eyelid reconstruction.

    PubMed

    Rajak, Saul N; Huilgol, Shyamala C; Murakami, Masahiro; Selva, Dinesh

    2018-03-14

    Propeller flaps are island flaps that reach the recipient site through an axial rotation. The flap has a subcutaneous pedicle on which it pivots, thereby resembling a helicopter propeller. We present our series of propeller flaps for the reconstruction of large eyelid defects. This is a retrospective review of the clinical case notes of eight patients that underwent tumour excision with reconstruction with a cutaneous propeller flap supplied by a non-perforator orbicularis pedicle between July and December 2016. Propeller flaps were used in the reconstruction of five lower lid defects (size range 19 × 5 mm to 25 × 8 mm), one medial canthus defect (13 mm diameter), one complete upper lid defect (42 × 19 mm diameter) and one lid sparing extenteration defect. The flaps were recruited from nasolabial, lateral canthal, temple or medial upper cheek skin. Post-operatively one case had 'trapdooring' which required flap revision at 4 months and one had persistent oedema that settled without intervention. The reconstruction of large eyelid defects is challenging in part because of the paucity of locally available skin. Propeller flaps are a paradigm shift in periocular reconstruction in which the subcutaneous pedicle enables the recruitment of large and highly mobile skin flaps from a wide area of regional tissue.

  8. Control of Flap Vortices

    NASA Technical Reports Server (NTRS)

    Greenblatt, David

    2005-01-01

    A wind tunnel investigation was carried out on a semi-span wing model to assess the feasibility of controlling vortices emanating from outboard flaps and tip-flaps by actively varying the degree of boundary layer separation. Separation was varied by means of perturbations produced from segmented zero-efflux oscillatory blowing slots, while estimates of span loadings and vortex sheet strengths were obtained by integrating wing surface pressures. These estimates were used as input to inviscid rollup relations as a means of predicting changes to the vortex characteristics resulting from the perturbations. Surveys of flow in the wake of the outboard and tip-flaps were made using a seven-hole probe, from which the vortex characteristics were directly deduced. Varying the degree of separation had a marked effect on vortex location, strength, tangential velocity, axial velocity and size for both outboard and tip-flaps. Qualitative changes in vortex characteristics were well predicted by the inviscid rollup relations, while the failure to account for viscosity was presumed to be the main reason for observed discrepancies. Introducing perturbations near the outboard flap-edges or on the tip-flap exerted significant control over vortices while producing negligible lift excursions.

  9. Computational Study of Porous Treatment for Altering Flap Side-Edge Flowfield

    NASA Technical Reports Server (NTRS)

    Choudhari, Meelan; Khorrami, Mehdi R.

    2003-01-01

    Reynolds-averaged Navier-Stokes calculations are used to investigate porous side-edge treatment as a passive means for flap noise reduction. Steady-state simulations are used to infer effects of the treatment on acoustically relevant features of the mean flow near the flap side edge. Application of the porous treatment over a miniscule fraction of the wetted flap area (scaling with the flap thickness) results in significantly weaker side-edge vortex structures via modification of the vortex initiation and roll-up processes. At high flap deflections, the region of axial flow reversal associated with the breakdown of the side-edge vortex is also eliminated, indicating an absence of vortex bursting in the presence of the treatment. Potential ramifications of the mean-flow modifications for flap-noise reduction are examined in the light of lessons learned from recent studies on flap noise. Computations confirm that any noise reduction benefit via the porous treatment would be achieved without compromising the aerodynamic effectiveness of the flap. Results of the parameter study contribute additional insight into the measured data from the 7x10 wind tunnel at NASA Ames and provide preliminary guidance for specifying optimal treatment characteristics in terms of treatment location, spatial extent, and flow resistance of the porous skin.

  10. Design, Manufacturing, and In Vitro Testing of a Patient-Specific Shape-Memory Expander for Nose Reconstruction With Forehead Flap Technique.

    PubMed

    Borghi, Alessandro; Rodgers, Will; Schievano, Silvia; Ponniah, Allan; O'Hara, Justine; Jeelani, Owase; Dunaway, David

    2016-01-01

    Forehead skin is widely acknowledged as a good donor site for total nasal reconstruction, thanks to its matching color, texture, and abundant vascularity. The forehead flap technique uses an axial pattern flap forehead skin to replace missing nasal tissue. To increase the amount of available tissue and reduce the size of the tissue defect after flap mobilization, tissue expanders may be used. Although this is a relatively established technique, limitations include reduced moldability of the forehead skin (which is thicker than the nasal skin), and the need for multiple sessions of expansion to achieve a sufficient yield to close the forehead.Shape-memory metals, such as nitinol, can be programmed to "remember" complex shapes. In this work, the methodology for producing a prototype of nitinol tissue expander able to mold the skin in a predetermined patient-specific skin shape is described. A realistic nose mold was manufactured using metal rapid prototyping; nitinol sheet and mesh were molded into nose-shape constructs, having hyperelastic as well as shape-memory capability. Computed tomography scanning was performed to assess the ability of the structure to regain its shape after phase transformation upon cooling within 2% of initial dimensions. The prototypes were implanted in a pig forehead to test its ability to impose a nose shape to the forehead skin.The shape-memory properties of nitinol offer the possibility of producing bespoke tissue expanders able to deliver complex, precisely designed skin envelopes. The hyperelastic properties of nitinol allow constant preprogrammed expansion forces to be generated throughout the expansion process.

  11. Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

    NASA Technical Reports Server (NTRS)

    Miller, Eric J.; Holguin, Andrew C.; Cruz, Josue; Lokos, William A.

    2014-01-01

    The safety-of-flight parameters for the Adaptive Compliant Trailing Edge (ACTE) flap experiment require that flap-to-wing interface loads be sensed and monitored in real time to ensure that the structural load limits of the wing are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces were monitored; each contained four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty-one applied test load cases were developed using the predicted in-flight loads. Pre-test predictions of strain gage responses were produced using finite element method models of the interface fittings. Predicted and measured test strains are presented. A load testing rig and three hydraulic jacks were used to apply combinations of shear, bending, and axial loads to the interface fittings. Hardware deflections under load were measured using photogrammetry and transducers. Due to deflections in the interface fitting hardware and test rig, finite element model techniques were used to calculate the reaction loads throughout the applied load range, taking into account the elastically-deformed geometry. The primary load equations were selected based on multiple calibration metrics. An independent set of validation cases was used to validate each derived equation. The 2-sigma residual errors for the shear loads were less than eight percent of the full-scale calibration load; the 2-sigma residual errors for the bending moment loads were less than three percent of the full-scale calibration load. The derived load equations for shear, bending, and axial loads are presented, with the calculated errors for both the calibration cases and the independent validation load cases.

  12. Freestyle multiple propeller flap reconstruction (jigsaw puzzle approach) for complicated back defects.

    PubMed

    Park, Sung Woo; Oh, Tae Suk; Eom, Jin Sup; Sun, Yoon Chi; Suh, Hyun Suk; Hong, Joon Pio

    2015-05-01

    The reconstruction of the posterior trunk remains to be a challenge as defects can be extensive, with deep dead space, and fixation devices exposed. Our goal was to achieve a tension-free closure for complex defects on the posterior trunk. From August 2006 to May 2013, 18 cases were reconstructed with multiple flaps combining perforator(s) and local skin flaps. The reconstructions were performed using freestyle approach. Starting with propeller flap(s) in single or multilobed design and sequentially in conjunction with adjacent random pattern flaps such as fitting puzzle. All defects achieved tensionless primary closure. The final appearance resembled a jigsaw puzzle-like appearance. The average size of defect was 139.6 cm(2) (range, 36-345 cm(2)). A total of 26 perforator flaps were used in addition to 19 random pattern flaps for 18 cases. In all cases, a single perforator was used for each propeller flap. The defect and the donor site all achieved tension-free closure. The reconstruction was 100% successful without flap loss. One case of late infection was noted at 12 months after surgery. Using multiple lobe designed propeller flaps in conjunction with random pattern flaps in a freestyle approach, resembling putting a jigsaw puzzle together, we can achieve a tension-free closure by distributing the tension to multiple flaps, supplying sufficient volume to obliterate dead space, and have reliable vascularity as the flaps do not need to be oversized. This can be a viable approach to reconstruct extensive defects on the posterior trunk. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Effects of spoilers and gear on B-747 wake vortex velocities

    NASA Technical Reports Server (NTRS)

    Luebs, A. B.; Bradfute, J. G.; Ciffone, D. L.

    1976-01-01

    Vortex velocities were measured in the wakes of four configurations of a 0.61-m span model of a B-747 aircraft. The wakes were generated by towing the model underwater in a ship model basin. Tangential and axial velocity profiles were obtained with a scanning laser velocimeter as the wakes aged to 35 span lengths behind the model. A 45 deg deflection of two outboard flight spoilers with the model in the landing configuration resulted in a 36 percent reduction in wake maximum tangential velocity, altered velocity profiles, and erratic vortex trajectories. Deployment of the landing gear with the inboard flaps in the landing position and outboard flaps retracted had little effect on the flap vortices to 35 spans, but caused the wing tip vortices to have: (1) more diffuse velocity profiles; (2) a 27 percent reduction in maximum tangential velocity; and (3) a more rapid merger with the flap vortices.

  14. Axial propulsion with flapping and rotating wings, a comparison of potential efficiency.

    PubMed

    Kroninger, Christopher M

    2018-04-18

    Interest in biological locomotion and what advantages the principles governing it might offer in the design of manmade vehicles prompts one to consider the power requirements of flapping relative to rotary propulsion. The amount of work performed on the fluid surrounding a thrusting surface (wing or blade) is reflected in the kinetic energy of the wake. Consideration of the energy in the wake is sufficient to define absolute minimum limitations on the power requirement to generate a particular thrust. This work applies wake solutions to compare the minimum inviscid propulsive power requirement of wings flapping and in rotation at wing loading conditions reflective of hover through a state of lightly-loaded cruise. It is demonstrated that hovering flapping flight is less efficient than rotary wing propulsion except for the most extreme flap amplitude strokes ([Formula: see text]   >  160°) if operating at large wake wavelength. In cruise, a larger range of flap amplitude kinematics ([Formula: see text]  >  140°) can be aerodynamically more energy efficient for wake wavelengths reflective of biological propulsion. These results imply, based on the observed wing kinematics of continuous steady flight, that flapping propulsion in animals is unlikely to be more efficient than rotary propulsion.

  15. The Golden Spiral Flap: A New Flap Design that Allows for Closure of Larger Wounds under Reduced Tension – How Studying Nature’s Own Design Led to the Development of a New Surgical Technique

    PubMed Central

    Paul, Sharad P.

    2016-01-01

    This paper details the study of biodynamic excisional skin tension lines on the scalp and the development of a new flap technique for closure of scalp wounds. Recently, a study by this author, on pigskin, replicated whorls by placing tissue under rapid stretch using saline tissue expanders, by recreating rapid dermo-epidermal shear of skin – thereby concluding that the golden spiral pattern is nature’s own pattern for rapid expansion. Given the relationship between tissue expansion and stretch has been shown to cause deformation gradients that have both elastic and growth factors, the author set out to test the hypothesis that a golden spiral pattern therefore would be more efficient at closing wounds under less tension when compared with standard semicircular rotational flap patterns. The author conducted a series of experiments, both on pigskin (to first confirm the hypothesis, using a recently developed computerized tensiometer) and later a clinical study. This paper presents a new random pivotal flap technique for skin closures on the head and neck: the golden spiral flap. Biomechanics, planning, and advantages of this new flap are described in this paper. PMID:27900320

  16. Effect of intradermal human recombinant copper-zinc superoxide dismutase on random pattern flaps in rats.

    PubMed

    Schein, Ophir; Westreich, Melvyn; Shalom, Avshalom

    2013-09-01

    Studies have focused on enhancing flap viability using superoxide dismutase (SOD), but only a few used SOD from human origin, and most gave the compound systemically. We evaluated the ability of SOD to improve random skin flap survival using human recombinant copper-zinc superoxide dismutase (Hr-CuZnSOD) in variable doses, injected intradermally into the flap. Seventy male Sprague Dawley rats were randomly assigned into 4 groups. Cephalic random pattern flaps were elevated on their backs and intradermal injections of different dosages of Hr-CuZnSOD were given 15 minutes before surgery. Flap survival was evaluated by fluorescein fluorescence. Analysis of variance (ANOVA) and t test statistical analyses were performed. Flap survival in all treated groups was significantly better than in the controls. The beneficial effect of HR-CuZnSOD on flap survival is attained when it is given intradermally into the flap tissue. Theoretically, Hr-CuZnSOD delivered with local anesthetics used in flap elevation may be a valuable clinical tool. Copyright © 2012 Wiley Periodicals, Inc.

  17. Axial crack propagation and arrest in pressurized fuselage

    NASA Technical Reports Server (NTRS)

    Kosai, M.; Shimamoto, A.; Yu, C.-T.; Walker, S. I.; Kobayashi, A. S.; Tan, P.

    1994-01-01

    The crack arrest capability of a tear strap in a pressurized precracked fuselage was studied through instrumented axial rupture tests of small scale models of an idealized fuselage. Upon pressurization, rapid crack propagation initiated at an axial through crack along the stringer and immediately kinked due to the mixed modes 1 and 2 state caused by the one-sided opening of the crack flap. The diagonally running crack further turned at the tear straps. Dynamic finite element analysis of the rupturing cylinder showed that the crack kinked and also ran straight in the presence of a mixed mode state according to a modified two-parameter crack kinking criterion.

  18. Vascular anatomy of the medial sural artery perforator flap: a new classification system of intra-muscular branching patterns.

    PubMed

    Dusseldorp, Joseph R; Pham, Quy J; Ngo, Quan; Gianoutsos, Mark; Moradi, Pouria

    2014-09-01

    The medial sural artery perforator (MSAP) flap is a versatile fasciocutaneous flap. The main difficulty encountered when raising the MSAP flap is in obtaining adequate pedicle length during intra-muscular dissection. The objective of this study was to determine the pattern of intra-muscular course of the MSAP flap pedicle. 14 cadaveric specimens were dissected and CT angiograms of 84 legs were examined. The intra-muscular branching pattern and depths of the medial sural artery branches were analyzed. The number of perforators, position of the dominant perforator and both intra-muscular and total pedicle length were also recorded and compared to existing anatomical data. Three types of arterial branching pattern were identified within the medial gastrocnemius, demonstrating one (31%), two (59%) or three or more (10%) main branches. A dominant perforator from the medial sural artery was present in 92% of anatomical specimens (13/14). Vertically, the location of the perforator from the popliteal crease was on average 13 cm (±2 cm). Transversely, the perforator originated 2.5 cm (±1 cm) from the posterior midline. Using CT angiography it was possible in 10 consecutive patients to identify a more superficial intra-muscular branch and determine the leg with the optimal branching pattern type for flap harvest. This study is the first to describe the variability of the intra-muscular arterial anatomy of the medial head of gastrocnemius muscle. Surgeons utilizing the MSAP flap option should be aware of the possible branching pattern types and consequently the differing perforator distribution and depths of intra-muscular branches. Routine use of pre-operative CT angiogram may help determine which leg has the most favorable branching pattern type and intra-muscular course for flap harvest. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. On the Application of Rapid Prototyping Technology for the Fabrication of Flapping Wings for Micro Air Vehicles

    NASA Astrophysics Data System (ADS)

    Kraemer, Kurtis Leigh

    Micro air vehicles (MAV) are a class of small uninhabited aircraft with dimensions less than 15 cm (6 in) and mass less than 500g (1.1 lbs). The aim of this research was to develop a fast, accurate, low-cost, and repeatable fabrication process for flapping MAV wings. Through the use of the RepRap Mendel open-source fused-deposition modeling (FDM) rapid prototyping machine ("3-D printer"), various wing prototypes were designed and fabricated using a bio-inspired approach. Testing of the aerodynamic performance of both real locust wings and the 3-D printed wing prototypes was performed through axial spin testing. Bending stiffness measurements were also performed on the 3-D printed wings. Through the use of open-source rapid prototyping technology, a fast and low-cost fabrication process for flapping MAV wings has been developed, out of which further understanding of flapping wing design and fabrication has been gained.

  20. Vascular Patterns and Perfusion of Mucogingival Tissues and their Relation to Periodontal Flap Design

    DTIC Science & Technology

    1987-05-01

    flaps were mosL vulnerable to necrosis . Sutures placed with minimal tension did not adversely affect blood perfusion of surgically replaced flaps. vi * C...perfusion change with narrow flaps most severely affected. In general, narrow thin flaps were most vulnerable to necrosis . Sutures placed with minimal...Day Narrow Pedicle ............. 75 B. Fluorescein Angiography of Envelope Flap Immediately Post Surgery and Necrosis of Marginal Third of Six

  1. Design and two dimensional cascade test of a jet-flap turbine stator blade with ratio of axial chord to spacing of 0.5

    NASA Technical Reports Server (NTRS)

    Stabe, R. G.

    1971-01-01

    A jet-flap blade was designed for a velocity diagram typical of the first-stage stator of a jet engine turbine and was tested in a simple two-dimensional cascade of six blades. The principal measurements were blade surface static pressure and cross-channel surveys of exit total pressure, static pressure, and flow angle. The results of the experimental investigation include blade loading, exit angle, flow, and loss data for a range of exit critical velocity ratios and three jet flow conditions.

  2. Prefabricated neck expanded skin flap with the superficial temporal vessels for facial resurfacing.

    PubMed

    Lazzeri, Davide; Su, Weijie; Qian, Yunliang; Messmer, Caroline; Agostini, Tommaso; Spinelli, Giuseppe; Marcus, Jeffrey R; Levin, L Scott; Zenn, Micheal R; Zhang, Yi Xin

    2013-05-01

    The achievement of a normal-appearing face after surgical resurfacing remains an elusive goal. This is due in part to insufficient color matching, restoration of contours, and the persistence of visible scars. Flap prefabrication is a staged procedure that provides an independent axial blood supply to local expanded tissues. We describe a new reconstructive alternative with superior reconstructive surgical options for facial resurfacing that better matches damaged or discarded facial tissues. A superficial temporal fascial flap was harvested as the vascular supply of the prefabricated neck flap and located in a subcutaneous neck pocket over a tissue expander. After a 5-month period for expansion and maturation, the prefabricated skin flap was raised, islanded, and rotated to resurface the facial defect. Four patients with hemifacial postburn contracture and two patients affected by hemifacial vascular malformations aged 17 to 42 years (mean 29 years) were successfully treated with no major complication after a mean period of 15 months. Prefabricated neck-expanded skin flap demonstrated an excellent color and texture match with facial skin that surrounded the repair sites, and optimal aesthetic results were obtained. Importantly, facial expression was completely maintained due to thinness and pliability of the rotated skin. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Does velopharyngeal closure pattern affect the success of pharyngeal flap pharyngoplasty?

    PubMed

    Armour, Alexis; Fischbach, Simone; Klaiman, Paula; Fisher, David M

    2005-01-01

    Historically at The Hospital for Sick Children in Toronto, pharyngeal flap pharyngoplasty has been the treatment of choice for treatment of velopharyngeal insufficiency, regardless of velopharyngeal closure pattern. The authors hypothesize that pharyngeal flap pharyngoplasty is more effective in treating velopharyngeal insufficiency in patients with circular or sagittal velopharyngeal closure and less effective in treating the coronal closure pattern. Ninety-three patients who underwent superiorly based pharyngeal flap surgery for velopharyngeal insufficiency were evaluated in a retrospective chart review. Closure pattern was determined preoperatively by nasopharyngoscopy or multiview videofluoroscopy. Nasalance was assessed preoperatively and at 6 weeks and 1 year postoperatively. Nasalance during nonnasal speech was decreased on average, for all closure patterns, postoperatively. However, a significantly higher percentage of patients were corrected to normal nasalance scores in thenoncoronal group than in the coronal group (57 percent versus 35 percent, respectively) at 1 year postoperatively (p < 0.05). Surgical overcorrection, as determined by postoperative hyponasality, occurred at a rate of 13 percent in the coronal group versus 7 percent in the noncoronal group (not statistically significant). The results demonstrate that hypernasality in patients with a coronal velopharyngeal closure pattern can be improved by pharyngeal flap pharyngoplasty. This procedure, however, is more frequently effective in correcting noncoronal closure pattern velopharyngeal insufficiency than coronal pattern velopharyngeal insufficiency. The authors are now more selective in their approach to the management of velopharyngeal insufficiency and are more inclined to treat coronal pattern velopharyngeal insufficiency with sphincter pharyngoplasty.

  4. Effect of input perturbation on the performance and wake dynamics of aquatic propulsion in heaving flexible foils

    NASA Astrophysics Data System (ADS)

    Lehn, Andrea M.; Thornycroft, Patrick J. M.; Lauder, George V.; Leftwich, Megan C.

    2017-02-01

    In this paper we consider the effects of adding high-frequency, low-amplitude perturbations to a smooth sinusoidal base input signal for a heaving panel in a closed loop flow tank. Specifically, 0.1 cm amplitude sinusoidal perturbation waves with frequency fp ranging from 0.5 to 13.0 Hz are added to 1 cm heave sinusoids with base frequencies, fb, ranging from 0.5 to 3.0 Hz. Two thin foils with different flexural stiffness are heaved with the combined input signals in addition to both the high-heave and low-heave signals independently. In all cases, the foils are heaved in a recirculating water channel with an incoming velocity of Vx=10 cm/s and a Reynolds number based on the chord length of Re=17 300 . Results demonstrate that perturbations increase the net axial force, in the streamwise direction, in most cases tested (with the exception of some poor performing flexible foil cases). Most significantly, for a base frequency of 1 Hz, perturbations at 9 Hz result in a 780.7% increase in net streamwise force production. Generally, the higher the perturbation frequency, fp the more axial force generated. However, for the stiffer foil, a clear peak in net force exists at fp=9 Hz , regardless of the base frequency. For the stiffer foil, swimming efficiency at a 1 Hz flapping frequency is increased dramatically with the addition of a perturbation, with reduced efficiency increases at higher flapping frequencies. Likewise, for the flexible foil, swimming efficiency gains are greatest at the lower flapping frequencies. Perturbations alter the wake structure by increasing the vorticity magnitude and increasing the vortex shedding frequency; i.e., more, stronger vortices are produced in each flapping cycle.

  5. The Effect of Omeprazole Usage on the Viability of Random Pattern Skin Flaps in Rats.

    PubMed

    Şen, Hilmi; Oruç, Melike; Işik, Veysel Murat; Sadiç, Murat; Sayar, Hamide; Çitil, Rana; Korkmaz, Meliha; Koçer, Uğur

    2017-06-01

    Necrosis of random pattern flaps caused by inadequate blood flow, especially in the distal part of the flap is one of the biggest challenges in reconstructive surgery. Various agents have been used to prevent flap ischemia. In this study, we used omeprazole, which is a potent inhibitor of gastric acidity to increase flap viability. In this study, 35 Wistar-Albino type rats which were divided into 5 equal groups were used. Random-pattern dorsal skin flaps were raised in all groups at seventh day of the study. Group 1 was accepted as control group, and the rats in this group was only given distilled water intraperitoneally for 14 days. Group 2 and group 3 received 10 and 40 mg/kg omeprazole daily for 14 days, respectively. Group 4 and group 5 were given distilled water for the first 7 days and then after the operations they received 10 and 40 mg/kg omeprazole daily for 7 days, respectively. Survival rates of the flaps were examined seventh day after elevation of the flaps by digital imaging and scintigraphy. After assessment of the amount of necrosis, number of vascular structures were counted histopathologically. Percentage of flap necrosis was found to be less in all omeprazole received groups. On digital imaging, percentages of flap necrosis in the study groups were statistically significantly lower than that of the control group (P < 0.001), but there was no significant difference between the study groups (P > 0.05).In the histopathologic specimens, it was detected that the mean number of vessels in proximal (a) and distal (c) portions of the flap in the study groups showed a significant increase when compared with the control group (P < 0.01 for groups 2, 4 and 5, and P < 0.05 for group 3). In conclusion, possible clinical usage of medications increasing gastrin during flap surgeries can be thought as a positive contributor. In this sense, this study showed that parenteral administration of omeprazole in skin flap surgery increases flap viability possibly by increasing gastrin levels.

  6. Indocyanine Green Fluorescence for Free-Flap Perfusion Imaging Revisited: Advanced Decision Making by Virtual Perfusion Reality in Visionsense Fusion Imaging Angiography.

    PubMed

    Bigdeli, Amir Khosrow; Gazyakan, Emre; Schmidt, Volker Juergen; Hernekamp, Frederick Jochen; Harhaus, Leila; Henzler, Thomas; Kremer, Thomas; Kneser, Ulrich; Hirche, Christoph

    2016-06-01

    Near-infrared indocyanine green video angiography (ICG-NIR-VA) has been introduced for free-flap surgery and may provide intraoperative flap designing as well as postoperative monitoring. Nevertheless, the technique has not been established in clinical routine because of controversy over benefits. Improved technical features of the novel Visionsense ICG-NIR-VA surgery system are promising to revisit the field of application. It features a unique real-time fusion image of simultaneous NIR and white light visualization, with highlighted perfusion, including a color-coded perfusion flow scale for optimized anatomical understanding. In a feasibility study, the Visionsense ICG-NIR-VA system was applied during 10 free-flap surgeries in 8 patients at our center. Indications included anterior lateral thigh (ALT) flap (n = 4), latissimus dorsi muscle flap (n = 1), tensor fascia latae flap (n = 1), and two bilateral deep inferior epigastric artery perforator flaps (n = 4). The system was used intraoperatively and postoperatively to investigate its impact on surgical decision making and to observe perfusion patterns correlated to clinical monitoring. Visionsense ICG-NIR-VA aided assessing free-flap design and perfusion patterns in all cases and correlated with clinical observations. Additional interventions were performed in 2 cases (22%). One venous anastomosis was revised, and 1 flap was redesigned. Indicated by ICG-NIR-VA, 1 ALT flap developed partial flap necrosis (11%). The Visionsense ICG-NIR-VA system allowed a virtual view of flap perfusion anatomy by fusion imaging in real-time. The system improved decision making for flap design and surgical decisions. Clinical and ICG-NIR-VA parameters correlated. Its future implementation may aid in improving outcomes for free-flap surgery, but additional experience is needed to define its final role. © The Author(s) 2015.

  7. Preliminary Measurements of the Noise Characteristics of Some Jet-Augmented-Flap Configurations

    NASA Technical Reports Server (NTRS)

    Maglieri, Domenic J.; Hubbard, Harvey H.

    1959-01-01

    Experimental noise studies were conducted on model configurations of some proposed jet-augmented flaps to determine their far-field noise characteristics. The tests were conducted using cold-air jets of circular and rectangular exits having equal areas, at pressure ratios corresponding to exit velocities slightly below choking. Results indicated that the addition of a flap to a nozzle may change both its noise radiation pattern and frequency spectrum. Large reductions in the noise radiated in the downward direction are realized when the flow from a long narrow rectangular nozzle as permitted to attach to and flow along a large flap surface. Deflecting or turning the jet flow by means of impingement on the under surfaces increases the noise radiated in all directions and especially in the downward direction for the jet-flap configurations tested. Turning of the flow from nozzles by means of a flap turns the noise pattern approximately an equal amount. The principle of using a jet-flap shield with flow attachment may have some application as a noise suppressor.

  8. Patient-specific reconstruction utilizing computer assisted 3D modelling for partial bone flap defect in hybrid cranioplasty

    NASA Astrophysics Data System (ADS)

    Hueh, Low Peh; Abdullah, Johari Yap; Abdullah, Abdul Manaf; Yahya, Suzana; Idris, Zamzuri; Mohamad, Dasmawati

    2016-12-01

    Autologous cranioplasty using a patient's original bone flap remain the commonest practice nowadays. However, partial bone flap defect is commonly encountered. Replacing the bone flap with pre-moulded synthetic bone flap is costly and not affordable to many patients. Hence most of the small to medium size defect was topped up with alloplastic material on a free hand basis intra-operatively which often resulted in inaccurate implant approximation with unsatisfactory cosmetic result. This study aims to evaluate implant accuracy and cosmetic outcome of cranioplasty candidates who underwent partial bone flap reconstruction utilising computer assisted 3D modelling. 3D images of the skull were obtained from post-craniectomy axial 1-mm spiral computed tomography (CT) scans and a virtual 3D model was generated using the Materialise Mimics software. The Materialise 3-Matic was then utilised to design a patient-specific implant. Prefabrication of the implant was performed by the 3D Objet printer, and a negative gypsum mold was created with the prefabricated cranial implant. Intraoperatively, a hybrid polymethyl methacrylate (PMMA)-autologous cranial implant was produced using the gypsum mold, and fit into the cranial defect. This study is still ongoing at the moment. To date, two men has underwent partial bone flap reconstruction utilising this technique and both revealed satisfactory implant alignment with favourable cosmesis. Mean implant size was 12cm2, and the mean duration of intraoperative reconstruction for the partial bone flap defect was 40 minutes. No significant complication was reported. As a conclusion, this new technique and approach resulted in satisfactory implant alignment and favourable cosmetic outcome. However, more study samples are needed to increase the validity of the study results.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, J. Z. G., E-mail: zma@mymail.ciis.edu; Hirose, A.

    By adopting Lembége & Pellat’s 2D plasma-sheet model, we investigate the flankward flapping motion and Sunward ballooning propagation driven by an external source (e.g., magnetic reconnection) produced initially at the sheet center. Within the ideal MHD framework, we adopt the WKB approximation to obtain the Taylor–Goldstein equation of magnetic perturbations. Fourier spectral method and Runge–Kutta method are employed in numerical simulations, respectively, under the flapping and ballooning conditions. Studies expose that the magnetic shears in the sheet are responsible for the flapping waves, while the magnetic curvature and the plasma gradient are responsible for the ballooning waves. In addition, themore » flapping motion has three phases in its temporal development: fast damping phase, slow recovery phase, and quasi-stabilized phase; it is also characterized by two patterns in space: propagating wave pattern and standing wave pattern. Moreover, the ballooning modes are gradually damped toward the Earth, with a wavelength in a scale size of magnetic curvature or plasma inhomogeneity, only 1–7% of the flapping one; the envelops of the ballooning waves are similar to that of the observed bursty bulk flows moving toward the Earth.« less

  10. Inlet Flow Test Calibration for a Small Axial Compressor Facility. Part 1: Design and Experimental Results

    NASA Technical Reports Server (NTRS)

    Miller, D. P.; Prahst, P. S.

    1994-01-01

    An axial compressor test rig has been designed for the operation of small turbomachines. The inlet region consisted of a long flowpath region with two series of support struts and a flapped inlet guide vane. A flow test was run to calibrate and determine the source and magnitudes of the loss mechanisms in the inlet for a highly loaded two-stage axial compressor test. Several flow conditions and IGV angle settings were established in which detailed surveys were completed. Boundary layer bleed was also provided along the casing of the inlet behind the support struts and ahead of the IGV. A detailed discussion of the flowpath design along with a summary of the experimental results are provided in Part 1.

  11. The Differential Use of Bilobed and Trilobed Transposition Flaps in Cutaneous Nasal Reconstructive Surgery.

    PubMed

    Knackstedt, Thomas; Lee, Kachiu; Jellinek, Nathaniel J

    2018-05-22

    Bilobed and trilobed transposition flaps are versatile random pattern transposition flaps which reliably restore nasal symmetry, topography, light reflex, contour and are frequently used in cutaneous nasal reconstructive surgery. We wish to compare the characteristics of bilobed and trilobed flaps in cutaneous reconstructive surgery and to identify scenarios for their differential use. A retrospective chart review over 7 years of consecutive patients reconstructed with a bilobed or trilobed flap after Mohs micrographic surgery was performed. Statistical analysis of patient and surgery characteristics, anatomic distribution, postprocedural events and need for revisions after both flap types was conducted. One hundred eleven patients with bilobed flaps and 74 patients with trilobed flaps were identified. Bilobed flaps are significantly more frequently used on the inferior nasal dorsum and on the sidewall whereas trilobed flaps are significantly more frequently used on the nasal tip and infratip. No significant difference in postprocedural events (complications, erythema, trapdoor, etc) was noted between the two flap types. Bilobed and trilobed transposition flaps are versatile repairs for nasal reconstruction. Trilobed flaps may be used to repair defects in a more distal nasal location than bilobed flaps. Regardless of flap type, complications are rare.

  12. Confined, Oriented, and Electrically Anisotropic Graphene Wrinkles on Bacteria.

    PubMed

    Deng, Shikai; Gao, Enlai; Wang, Yanlei; Sen, Soumyo; Sreenivasan, Sreeprasad Theruvakkattil; Behura, Sanjay; Král, Petr; Xu, Zhiping; Berry, Vikas

    2016-09-27

    Curvature-induced dipole moment and orbital rehybridization in graphene wrinkles modify its electrical properties and induces transport anisotropy. Current wrinkling processes are based on contraction of the entire substrate and do not produce confined or directed wrinkles. Here we show that selective desiccation of a bacterium under impermeable and flexible graphene via a flap-valve operation produces axially aligned graphene wrinkles of wavelength 32.4-34.3 nm, consistent with modified Föppl-von Kármán mechanics (confinement ∼0.7 × 4 μm(2)). Further, an electrophoretically oriented bacterial device with confined wrinkles aligned with van der Pauw electrodes was fabricated and exhibited an anisotropic transport barrier (ΔE = 1.69 meV). Theoretical models were developed to describe the wrinkle formation mechanism. The results obtained show bio-induced production of confined, well-oriented, and electrically anisotropic graphene wrinkles, which can be applied in electronics, bioelectromechanics, and strain patterning.

  13. Forelimb muscle function in pig-nosed turtles, Carettochelys insculpta: testing neuromotor conservation between rowing and flapping in swimming turtles

    PubMed Central

    Rivera, Angela R. V.; Blob, Richard W.

    2013-01-01

    Changes in muscle activation patterns can lead to new locomotor modes; however, neuromotor conservation—the evolution of new forms of locomotion through changes in structure without concurrent changes to underlying motor patterns—has been documented across diverse styles of locomotion. Animals that swim using appendages do so via rowing (anteroposterior oscilations) or flapping (dorsoventral oscilations). Yet few studies have compared motor patterns between these swimming modes. In swimming turtles, propulsion is generated exclusively by limbs. Kinematically, turtles swim using multiple styles of rowing (freshwater species), flapping (sea turtles) and a unique hybrid style with superficial similarity to flapping by sea turtles and characterized by increased dorsoventral motions of synchronously oscillated forelimbs that have been modified into flippers (Carettochelys insculpta). We compared forelimb motor patterns in four species of turtle (two rowers, Apalone ferox and Trachemys scripta; one flapper, Caretta caretta; and Carettochelys) and found that, despite kinematic differences, motor patterns were generally similar among species with a few notable exceptions: specifically, presence of variable bursts for pectoralis and triceps in Trachemys (though timing of the non-variable pectoralis burst was similar), and the timing of deltoideus activity in Carettochelys and Caretta compared with other taxa. The similarities in motor patterns we find for several muscles provide partial support for neuromotor conservation among turtles using diverse locomotor styles, but the differences implicate deltoideus as a prime contributor to flapping limb motions. PMID:23966596

  14. Flow field over the wing of a delta-wing fighter model with vortex control devices at Mach 0.6 to 1.2

    NASA Technical Reports Server (NTRS)

    Bare, E. Ann; Reubush, David E.; Haddad, Raymond C.

    1992-01-01

    As part of a cooperative research program between NASA, McDonnell Douglas Corporation, and Wright Research and Development Center, a flow field investigation was conducted on a 7.52 percent scale windtunnel model of an advanced fighter aircraft design. The investigation was conducted in the Langley 16 ft Transonic Tunnel at Mach numbers of 0.6, 0.9, and 1.2. Angle of attack was varied from -4 degrees to 30 degrees and the model was tested at angles of sideslip of 0, 5, and -5 degrees. Data for the over the wing flow field were obtained at four axial survey stations by the use of six 5 hole conical probes mounted on a survey mechanism. The wing leading edge primary vortex exerted the greatest influence in terms of total pressure loss on the over the wing flow field in the area surveyed. A number of vortex control devices were also investigated. They included two different apex flaps, wing leading edge vortex flaps, and small large wing fences. The vortex flap and both apex flaps were beneficial in controlling the wing leading edge primary vortex.

  15. Design of Mini Latissimus Dorsi Flap Based on Thoracodorsal Vascular Patterns.

    PubMed

    Elzawawy, Ehab Mostafa; Kelada, Melad Naim; Al Karmouty, Ahmed Farouk

    2018-06-01

    Latissimus dorsi (LD) flap has been used for reconstructive purposes in oncoplastic breast surgery. Using large part of the muscle as a flap leads to a residual functional loss. Muscle sparing and mini LD flaps can be used with no functional sequelae. However, the design of such flap presents a challenge. Twenty cadavers were dissected on both sides to identify the different vascular patterns of the thoracodorsal (TD) pedicle. The vessels were counted, and the following measurements were taken: diameter, length, distance from inferior angel of scapula, and vertebral level. Data were collected and entered into the personal computer. Statistical analysis was done using (SPSS/version 20) software. Five vascular patterns of TD pedicle were found. Type 1: a long vertically descending pedicle giving 3 to 4 transverse medial branches to LD in 40%. Type 2: a short pedicle terminating into 1 to 2 serratus anterior collaterals and 1 to 2 transverse lateral branches to LD in 10%. Type 3: a long vertically descending pedicle giving 2 to 3 small lateral branches to upper part of LD and terminating into medial and lateral branches in the lower part of LD in 10%. Type 4: a short pedicle that gives 4 to 5 terminal branches to LD, one of them is a long vertically descending branch to lower part of LD in 20%. Type 5: a short pedicle that terminates into a transverse medial and a long vertical branch to LD in 20%. The classically described pattern of TD pedicle (type 5) was found in 20% of cases, whereas the most commonly found pattern was type 1. This means that the pattern of TD branching is unpredictable, and a preoperative ultrasound is essential to define the existing pattern and plan the best LD flap design for each patient. In types 1 and 5, the flap can be designed using the transverse medial branch or branches. In type 2, one of the lateral transverse branches can be used. In types 3, 4, and 5, the long descending vertical branch can be used. It has a sizeable diameter (1.80.23 mm), length (12.31.64 cm), and can be located 6.50.96 cm below the inferior angle of scapula.

  16. Topical application of nitrosonifedipine, a novel radical scavenger, ameliorates ischemic skin flap necrosis in a mouse model.

    PubMed

    Fukunaga, Yutaka; Izawa-Ishizawa, Yuki; Horinouchi, Yuya; Sairyo, Eriko; Ikeda, Yasumasa; Ishizawa, Keisuke; Tsuchiya, Koichiro; Abe, Yoshiro; Hashimoto, Ichiro; Tamaki, Toshiaki

    2017-04-01

    Ischemic skin flap necrosis can occur in random pattern flaps. An excess amount of reactive oxygen species is generated and causes necrosis in the ischemic tissue. Nitrosonifedipine (NO-NIF) has been demonstrated to possess potent radical scavenging ability. However, there has been no study on the effects of NO-NIF on ischemic skin flap necrosis. Therefore, they evaluated the potential of NO-NIF in ameliorating ischemic skin flap necrosis in a mouse model. A random pattern skin flap (1.0 × 3.0 cm) was elevated on the dorsum of C57BL/6 mice. NO-NIF was administered by topical injection immediately after surgery and every 24 hours thereafter. Flap survival was evaluated on postoperative day 7. Tissue samples from the skin flaps were harvested on postoperative days 1 and 3 to analyze oxidative stress, apoptosis and endothelial dysfunction. The viable area of the flap in the NO-NIF group was significantly increased (78.30 ± 7.041%) compared with that of the control group (47.77 ± 6.549%, p < 0.01). NO-NIF reduced oxidative stress, apoptosis and endothelial dysfunction, which were evidenced by the decrease of malondialdehyde, p22phox protein expression, number of apoptotic cells, phosphorylated p38 MAPK protein expression, and vascular cell adhesion molecule-1 protein expression while endothelial nitric oxide synthase protein expression was increased. In conclusion, they demonstrated that NO-NIF ameliorated ischemic skin flap necrosis by reducing oxidative stress, apoptosis, and endothelial dysfunction. NO-NIF is considered to be a candidate for the treatment of ischemic flap necrosis. © 2017 by the Wound Healing Society.

  17. Prefabricated Cervical Skin Flaps for Hemi-Facial Resurfacing: Elucidating the Natural History of Postoperative Edema Using Indocyanine Green.

    PubMed

    Li, Ke; Min, Peiru; Sadigh, Parviz; Grassetti, Luca; Lazzeri, Davide; Torresetti, Matteo; Marsili, Riccardo; Feng, Shaoqing; Liu, Ningfei; Zhang, Yi Xin

    2018-02-01

    The increases in capillary wall permeability and capillary hydrostatic pressure are considered to be the causes for the acute swelling seen in flaps; however, disruption of the circulating flap lymphatics could be another contributory factor. In this study we monitor the development of flap edema in a series of 18 prefabricated flaps and aim to delineate the natural history of this phenomenon by use of lymphography. Postoperative swelling was monitored in a series of 18 pre-expanded prefabricated cervical skin flaps used for hemi-facial burns-scar resurfacing. Time to spontaneous resolution, presence or absence of venous congestion, and clinical outcome were recorded. In two cases, indocyanine-green (ICG) lymphography was used to monitor the dermal backflow pattern until swelling had completely resolved. Average moving velocity of ICG after injection as well as flap thickness was also recorded over the follow-up period. The average moving velocity of ICG in the flap lymphatics improved from 0.48 cm/min to 1.5 cm/min in the first 12 days after flap transfer. The dermal backflow pattern was stardust in the first 12 days, indicating moderate lymphedema, transforming to splash from week three, and a robust collecting lymphatic vessel occurring from the fifth month, indicating mild lymphedema and lymphatic channel recovery, respectively. Transient swelling was observed in all prefabricated flaps in our series. We postulate that this is mostly secondary to lymphatic disruption that subsides as lymphangiogenesis takes place. ICG lymphography is an inexpensive, safe, and easy-to-use imaging technology that could be used in the monitoring of postoperative lymphedema seen in prefabricated flaps.

  18. Dynamic perfusion assessment during perforator flap surgery: an up-to-date

    PubMed Central

    MUNTEAN, MAXIMILIAN VLAD; MUNTEAN, VALENTIN; ARDELEAN, FILIP; GEORGESCU, ALEXANDRU

    2015-01-01

    Flap monitoring technology has progressed alongside flap design. The highly variable vascular anatomy and the complexity associated with modern perforator flaps demands dynamic, real-time, intraoperative information about the vessel location, perfusion patterns and flap physiology. Although most surgeons still assess flap perfusion and viability based solely on clinical experience, studies have shown that results may be highly variable and often misleading. Poor judgment of intraoperative perfusion leads to major complications. Employing dynamic perfusion imaging during flap reconstruction has led to a reduced complication rate, lower morbidity, shorter hospital stay, and an overall better result. With the emergence of multiple systems capable of intraoperative flap evaluation, the purpose of this article is to review the two systems that have been widely accepted and are currently used by plastic surgeons: Indocyanine green angiography (ICGA) and dynamic infrared thermography (DIRT). PMID:26609259

  19. Bilateral pedicled myocutaneous vertical rectus abdominus muscle flaps to close vesicovaginal and pouch-vaginal fistulas with simultaneous vaginal and perineal reconstruction in irradiated pelvic wounds.

    PubMed

    Horch, Raymund E; Gitsch, G; Schultze-Seemann, W

    2002-09-01

    Chronic postoperative pouch-vaginal and vesicovaginal fistulas after hysterectomy and irradiation to treat advanced cervical cancer do not respond to conventional treatment because of the low vascularity in the irradiated area. We present the successful repair of these complications in a female patient, in whom several vaginal and abdominal approaches had been tried and had resulted not only in failure but also in tissue loss and fibrosis and persisting fistulas. First, a synchronous vaginoabdominal approach using a vertical myocutaneous distally based rectus abdominis myocutaneous flap was used successfully to close a pouch-vaginal fistula and simultaneously reconstruct the posterior vaginal wall. In a second approach, the persisting vesicovaginal fistula was closed by a right rectus abdominis myocutaneous flap while simultaneously reconstructing the anterior vaginal wall, closing the enterocutaneous stoma and performing an appendicovesicostomy as a continence channel for catheterization. Despite unfavorable local wound situations, including an enterocutaneous stoma through the rectus abdominis and various previous incision lines, the transfer of axially well-vascularized tissue can solve these problem wounds. Consecutive bilateral use of the rectus abdominis flap may be necessary to deal with extensive pelvic wounds. This technique should be considered as one repair modality in irradiated pelvic wounds with fistulas. Previous enterostomy is not a contraindication to the use of this flap.

  20. Development of Bird-like Micro Aerial Vehicle with Flapping and Feathering Wing Motions

    NASA Astrophysics Data System (ADS)

    Maglasang, Jonathan; Goto, Norihiro; Isogai, Koji

    To investigate the feasibility of a highly efficient flapping system capable of avian maneuvers, such as rapid takeoff, hover and gliding, a full scale bird-like (ornithopter) flapping-wing micro aerial vehicle (MAV) shaped and patterned after a typical pigeon (Columba livia) has been designed and constructed. Both numerical and experimental methods have been used in the development of this vehicle. This flapping-wing micro aerial vehicle utilizes both the flapping and feathering motions of an avian wing by employing a novel flapping-feathering mechanism, which has been synthesized and constructed so as to best describe the properly coordinated flapping and feathering wing motions at phase angle difference of 90° in a horizontal steady level flight condition. This design allows high flapping and feathering amplitudes and is configurable for asymmetric wing motions which are desirable in high-speed flapping flight and maneuvering. The preliminary results indicate its viability as a practical and an efficient flapping-wing micro aerial vehicle.

  1. Externally-blown-flap noise

    NASA Technical Reports Server (NTRS)

    Dorsch, R. G.; Kreim, W. J.; Olsen, W. A.

    1972-01-01

    Noise data were obtained with a large externally blown flap model. A fan-jet engine exhaust was simulated by a 1/2-scale bypass nozzle supplied by pressurized air. The nozzle was pylon mounted on a wing section having a double-slotted flap for lift augmentation. Noise radiation patterns and spectra were obtained for nozzle exhaust velocities between 400 and 1150 ft/sec. The blown flap noise data are in good agreement with previous small model results extrapolated to test conditions by Strouhal scaling. The results indicate that blown flap noise must be suppressed to meet STOL aircraft noise goals.

  2. Annular Internal-External-Expansion Rocket Nozzles for Large Booster Applications

    NASA Technical Reports Server (NTRS)

    Connors, James F.; Cubbison, Robert W.; Mitchell, Glenn A.

    1961-01-01

    For large-thrust booster applications, annular rocket nozzles employing both internal and external expansion are investigated. In these nozzles, free-stream air flows through the center as well as around the outside of the exiting jet. Flaps for deflecting the rocket exhaust are incorporated on the external-expansion surface for thrust-vector control. In order to define nozzle off-design performance, thrust vectoring effectiveness, and external stream effects, an experimental investigation was conducted on two annular nozzles with area ratios of 15 and 25 at Mach 0, 2, and 3 in the Lewis 10- by 10-foot wind tunnel. Air, pressurized to 600 pounds per square inch absolute, was used to simulate the exhaust flow. For a nozzle-pressure-ratio range of 40 to 1000, the ratio of actual to ideal thrust was essentially constant at 0.98 for both nozzles. Compared with conventional convergent-divergent configurations on hypothetical boost missions, the performance gains of the annular nozzle could yield significant orbital payload increases (possibly 8 to 17 percent). A single flap on the external-expansion surface of the area-ratio-25 annular nozzle produced a side force equal to 4 percent of the axial force with no measurable loss in axial thrust.

  3. Three-dimensional contrast-enhanced magnetic resonance angiography for anterolateral thigh flap outlining: A retrospective case series of 68 patients.

    PubMed

    Jiang, Chunjing; Lin, Ping; Fu, Xiaoyan; Shu, Jiner; Li, Huimin; Hu, Xiaogang; He, Jianrong; Ding, Mingxing

    2016-08-01

    Flap transfer is increasingly used for repairing limb defects secondary to trauma or tumor, and appropriate preoperative planning plays a critical role. The present study aimed to examine the use of three-dimensional (3D) contrast-enhanced magnetic resonance angiography (CE-MRA) in evaluating the blood supply distribution and perforating branch pattern of anterolateral thigh (ALT) flaps. Bilateral donor lower limbs were scanned in 68 patients (136 limbs) using a Siemens Avanto 1.5 T magnetic resonance imaging scanner with a 3D fast low-angle shot sequence, following the thin-slab maximum intensity projection (TS-MIP) technique. The lateral femoral circumflex artery (LFCA) was visualized in all patients: 101 limbs (101/136, 74.3%) were type I; 20 limbs (20/136, 14.7%) were type II; 3 limbs (3/136, 2.2%) were type III; and 12 limbs (12/136, 8.8%) were type IV. Tertiary branches were identified in 94 limbs (94/136, 69.1%). Donor flaps were outlined according to MRA TS-MIP findings in 4 patients. All flaps survived uneventfully following the transfer. In donor flap outlining, 3D CE-MRA with the TS-MIP technique allowed an accurate, direct visualization of the branching pattern and distribution profile of the LFCA supplying the ALT flap.

  4. Benchmarking aerodynamic prediction of unsteady rotor aerodynamics of active flaps on wind turbine blades using ranging fidelity tools

    NASA Astrophysics Data System (ADS)

    Barlas, Thanasis; Jost, Eva; Pirrung, Georg; Tsiantas, Theofanis; Riziotis, Vasilis; Navalkar, Sachin T.; Lutz, Thorsten; van Wingerden, Jan-Willem

    2016-09-01

    Simulations of a stiff rotor configuration of the DTU 10MW Reference Wind Turbine are performed in order to assess the impact of prescribed flap motion on the aerodynamic loads on a blade sectional and rotor integral level. Results of the engineering models used by DTU (HAWC2), TUDelft (Bladed) and NTUA (hGAST) are compared to the CFD predictions of USTUTT-IAG (FLOWer). Results show fairly good comparison in terms of axial loading, while alignment of tangential and drag-related forces across the numerical codes needs to be improved, together with unsteady corrections associated with rotor wake dynamics. The use of a new wake model in HAWC2 shows considerable accuracy improvements.

  5. Beneficial aerodynamic effect of wing scales on the climbing flight of butterflies.

    PubMed

    Slegers, Nathan; Heilman, Michael; Cranford, Jacob; Lang, Amy; Yoder, John; Habegger, Maria Laura

    2017-01-30

    It is hypothesized that butterfly wing scale geometry and surface patterning may function to improve aerodynamic efficiency. In order to investigate this hypothesis, a method to measure butterfly flapping kinematics optically over long uninhibited flapping sequences was developed. Statistical results for the climbing flight flapping kinematics of 11 butterflies, based on a total of 236 individual flights, both with and without their wing scales, are presented. Results show, that for each of the 11 butterflies, the mean climbing efficiency decreased after scales were removed. Data was reduced to a single set of differences of climbing efficiency using are paired t-test. Results show a mean decrease in climbing efficiency of 32.2% occurred with a 95% confidence interval of 45.6%-18.8%. Similar analysis showed that the flapping amplitude decreased by 7% while the flapping frequency did not show a significant difference. Results provide strong evidence that butterfly wing scale geometry and surface patterning improve butterfly climbing efficiency. The authors hypothesize that the wing scale's effect in measured climbing efficiency may be due to an improved aerodynamic efficiency of the butterfly and could similarly be used on flapping wing micro air vehicles to potentially achieve similar gains in efficiency.

  6. The influence of aspect ratio and stroke pattern on force generation of a bat-inspired membrane wing.

    PubMed

    Schunk, Cosima; Swartz, Sharon M; Breuer, Kenneth S

    2017-02-06

    Aspect ratio (AR) is one parameter used to predict the flight performance of a bat species based on wing shape. Bats with high AR wings are thought to have superior lift-to-drag ratios and are therefore predicted to be able to fly faster or to sustain longer flights. By contrast, bats with lower AR wings are usually thought to exhibit higher manoeuvrability. However, the half-span ARs of most bat wings fall into a narrow range of about 2.5-4.5. Furthermore, these predictions do not take into account the wide variation in flapping motion observed in bats. To examine the influence of different stroke patterns, we measured lift and drag of highly compliant membrane wings with different bat-relevant ARs. A two degrees of freedom shoulder joint allowed for independent control of flapping amplitude and wing sweep. We tested five models with the same variations of stroke patterns, flapping frequencies and wind speed velocities. Our results suggest that within the relatively small AR range of bat wings, AR has no clear effect on force generation. Instead, the generation of lift by our simple model mostly depends on wingbeat frequency, flapping amplitude and freestream velocity; drag is mostly affected by the flapping amplitude.

  7. The influence of aspect ratio and stroke pattern on force generation of a bat-inspired membrane wing

    PubMed Central

    Swartz, Sharon M.; Breuer, Kenneth S.

    2017-01-01

    Aspect ratio (AR) is one parameter used to predict the flight performance of a bat species based on wing shape. Bats with high AR wings are thought to have superior lift-to-drag ratios and are therefore predicted to be able to fly faster or to sustain longer flights. By contrast, bats with lower AR wings are usually thought to exhibit higher manoeuvrability. However, the half-span ARs of most bat wings fall into a narrow range of about 2.5–4.5. Furthermore, these predictions do not take into account the wide variation in flapping motion observed in bats. To examine the influence of different stroke patterns, we measured lift and drag of highly compliant membrane wings with different bat-relevant ARs. A two degrees of freedom shoulder joint allowed for independent control of flapping amplitude and wing sweep. We tested five models with the same variations of stroke patterns, flapping frequencies and wind speed velocities. Our results suggest that within the relatively small AR range of bat wings, AR has no clear effect on force generation. Instead, the generation of lift by our simple model mostly depends on wingbeat frequency, flapping amplitude and freestream velocity; drag is mostly affected by the flapping amplitude. PMID:28163875

  8. The dorsal thoracic fascia: anatomic significance with clinical applications in reconstructive microsurgery.

    PubMed

    Kim, P S; Gottlieb, J R; Harris, G D; Nagle, D J; Lewis, V L

    1987-01-01

    The anatomic distribution and potential arterial flow patterns of the circumflex scapular artery were investigated by Microfil injection. These studies demonstrated that the circumflex scapular artery lies within the dorsal thoracic fascia, which plays a significant role in the circulation of the overlying skin and subcutaneous tissue. We conclude that scapular/parascapular flaps are fasciocutaneous flaps, the dorsal thoracic fascia can be transferred as a free flap without its overlying skin and subcutaneous tissue, and intercommunication exists between the myocutaneous perforators of the latissimus dorsi myocutaneous flap and the vascular plexus of the dorsal thoracic fascia. We present microvascular cases in which the vascular properties of the dorsal thoracic fascia facilitated wound closure with free fascia flaps or expanded cutaneous or myocutaneous flaps.

  9. A New Technique for Coronaplasty in Penile Reconstruction.

    PubMed

    Sommeling, Casper E; De Wolf, Edward J; Salim, Ali; Monstrey, Stan; Opsomer, Dries; Claes, Karel; D'Arpa, Salvatore

    2018-06-01

    The coronaplasty is an important step of the phalloplasty procedure as it creates a prominent coronal ridge and a constricted coronal sulcus, resulting in the transformation of a regular skin flap into a flap resembling a circumcised penis. The aim of this article is to describe our new coronaplasty technique that exploits opposing contracting forces of 2 different skin grafts to hold the shape of a thick, distally based skin flap, resulting in a natural looking neo-phallus. A distally based flap is raised at the junction of the middle and distal thirds of the neo-phallus. The dissection continues until adequate mobilization is obtained, so the flap can stand almost perpendicular to the axis of the shaft. 2 separate full-thickness skin grafts are harvested and placed: the first at the raw undersurface of the flap, the second at the flap's donor site. To make the sulcus deeper and to define the ridge, the lower part of the graft placed on the undersurface of the distal flap is sutured with tacking sutures. Depending on the type of flap used this procedure can be done during the phalloplasty procedure itself (axial flaps) or at least 1 week later (perforator flaps). The new technique that we developed shows a more distinct coronal sulcus and coronal ridge, long-lasting results, and a more aesthetically pleasing and natural-appearing glans penis. The harvested distal flap is progressively thicker and not folded, resulting in a more naturally looking ridge. The donor site is deeper than other techniques, creating a well-defined sulcus. By using 2 skin grafts the opposing force vectors increase the projection of the ridge and the deepness of the sulcus. This technique results in a more prominent glans penis and is an important step in creating an almost naturally looking neo-phallus. This procedure can be applied to all different kind of flaps used for phalloplasty, both in an immediate or delayed fashion. As grafts are used, partial or complete graft lost can appear. Furthermore, attention must be paid not to incise the distal flap too deep so vascularity to the distal part of the flap will not be impaired. A continuous search to optimize the aesthetic outcome of the phalloplasty procedure is necessary and with this new coronaplasty technique we hope to raise attention and take another step toward creating "the real thing." Sommeling CE, De Wolf EJ, Salim A, et al. A New Technique for Coronaplasty in Penile Reconstruction. J Sex Med 2018;15:920-923. Copyright © 2018 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  10. Management of Vortices Trailing Flapped Wings via Separation Control

    NASA Technical Reports Server (NTRS)

    Greenblatt, David

    2005-01-01

    A pilot study was conducted on a flapped semi-span model to investigate the concept and viability of near-wake vortex management via separation control. Passive control was achieved by means of a simple fairing and active control was achieved via zero mass-flux blowing slots. Vortex sheet strength, estimated by integrating surface pressure ports, was used to predict vortex characteristics by means of inviscid rollup relations. Furthermore, vortices trailing the flaps were mapped using a seven-hole probe. Separation control was found to have a marked effect on vortex location, strength, tangential velocity, axial velocity and size over a wide range of angles of attack and control conditions. In general, the vortex trends were well predicted by the inviscid rollup relations. Manipulation of the separated flow near the flap edges exerted significant control over both outboard and inboard edge vortices while producing negligible lift excursions. Dynamic separation and attachment control was found to be an effective means for dynamically perturbing the vortex from arbitrarily long wavelengths down to wavelengths less than a typical wingspan. In summary, separation control has the potential for application to time-independent or time-dependent wake alleviation schemes, where the latter can be deployed to minimize adverse effects on ride-quality and dynamic structural loading.

  11. Optimization design and dynamic analysis on the drive mechanisms of flapping-wing air vehicles based on flapping trajectories

    NASA Astrophysics Data System (ADS)

    Xie, Lingwang; Zhang, Xingwei; Luo, Pan; Huang, Panpan

    2017-10-01

    The optimization designs and dynamic analysis on the driving mechanism of flapping-wing air vehicles on base of flapping trajectory patterns is carried out in this study. Three different driving mechanisms which are spatial double crank-rocker, plane five-bar and gear-double slider, are systematically optimized and analysed by using the Mat lab and Adams software. After a series debugging on the parameter, the comparatively ideal flapping trajectories are obtained by the simulation of Adams. Present results indicate that different drive mechanisms output different flapping trajectories and have their unique characteristic. The spatial double crank-rocker mechanism can only output the arc flapping trajectory and it has the advantages of small volume, high flexibility and efficient space utilization. Both planar five-bar mechanism and gear-double slider mechanism can output the oval, figure of eight and double eight flapping trajectories. Nevertheless, the gear-double slider mechanism has the advantage of convenient parameter setting and better performance in output double eight flapping trajectory. This study can provide theoretical basis and helpful reference for the design of the drive mechanisms of flapping-wing air vehicles with different output flapping trajectories.

  12. Vascularized osseous flaps and assessing their bipartate perfusion pattern via intraoperative fluorescence angiography.

    PubMed

    Valerio, Ian; Green, J Marshall; Sacks, Justin M; Thomas, Shane; Sabino, Jennifer; Acarturk, T Oguz

    2015-01-01

    Large segmental bone and composite tissue defects often require vascularized osseous flaps for definitive reconstruction. However, failed osseous flaps due to inadequate perfusion can lead to significant morbidity. Utilization of indocyanine green (ICG) fluorescence angiography has been previously shown to reliably assess soft tissue perfusion. Our group will outline the application of this useful intraoperative tool in evaluating the perfusion of vascularized osseous flaps. A retrospective review was performed to identify those osseous and/or osteocutaneous bone flaps, where ICG angiography was employed. Data analyzed included flap types, success and failure rates, and perfusion-related complications. All osseous flaps were evaluated by ICG angiography to confirm periosteal and endosteal perfusion. Overall 16 osseous free flaps utilizing intraoperative ICG angiography to assess vascularized osseous constructs were performed over a 3-year period. The flaps consisted of the following: nine osteocutaneous fibulas, two osseous-only fibulas, two scapular/parascapular with scapula bone, two quadricep-based muscle flaps, containing a vascularized femoral bone component, and one osteocutaneous fibula revision. All flap reconstructions were successful with the only perfusion-related complication being a case of delayed partial skin flap loss. Intraoperative fluorescence angiography is a useful adjunctive tool that can aid in flap design through angiosome mapping and can also assess flap perfusion, vascular pedicle flow, tissue perfusion before flap harvest, and flap perfusion after flap inset. Our group has successfully extended the application of this intraoperative tool to assess vascularized osseous flaps in an effort to reduce adverse outcomes related to preventable perfusion-related complications. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Flapping modes of three filaments placed side by side in a free stream

    NASA Astrophysics Data System (ADS)

    Tian, Fang-Bao; Luo, Haoxiang; Zhu, Luoding; Lu, Xi-Yun

    2010-11-01

    Flexible filaments flapping in a surrounding flow are useful models for understanding the flow-induced vibration and mimicking the schooling behavior of fish. In the present work, the coupled modes of three identical filaments in a side-by- side arrangement are studied using the linear stability analysis and also an immersed boundary--lattice Boltzmann method for low Reynolds numbers (Re on order of 100). The numerical simulations show that the system dynamics exhibits several patterns that depend on the spacing between the filaments. Among these patterns, three can be predicted by the linear analysis and have been reported before. These modes are: (1) the three filaments all flap in phase; (2) the two outer filaments are out of phase while the middle one is stable; (3) the two outer filaments are in phase while the middle one is out of phase. The simulations also identified two additional modes: (1) the outer two filaments are out of phase while the middle one flaps at a frequency reduced by half; (2) the outer two filaments are out of phase while the middle one flaps at a slightly different frequency. In addition to the vibratory modes, the drag force and the flapping amplitude are also computed, and the implication of the result will be discussed.

  14. Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

    PubMed

    Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew

    2014-01-01

    Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.

  15. The influence of geometry on jet plume development

    NASA Astrophysics Data System (ADS)

    Xia, H.; Tucker, P. G.; Eastwood, S.; Mahak, M.

    2012-07-01

    Our recent efforts of using large-eddy simulation (LES) type methods to study complex and realistic geometry single stream and co-flow nozzle jets and acoustics are summarized in this paper. For the LES, since the solver being used tends towards having dissipative qualities, the subgrid scale (SGS) model is omitted, giving a numerical type LES (NLES). To overcome near wall streak resolution problems a near wall RANS (Reynolds averaged Navier-Stokes) model is smoothly blended in the LES making a hybrid RANS-NLES approach. Several complex nozzle geometries including the serrated (chevron) nozzle, realistic co-axial nozzles with eccentricity, pylon and wing-flap are discussed. The hybrid RANS-NLES simulations show encouraging predictions for the chevron jets. The chevrons are known to increase the high frequency noise at high polar angles, but decrease the low frequency noise at lower angles. The deflection effect of the potential core has an important mechanism of noise reduction. As for co-axial nozzles, the eccentricity, the pylon and the deployed wing-flap are shown to influence the flow development, especially the former to the length of potential core and the latter two having a significant impact on peak turbulence levels and spreading rates. The studies suggest that complex and real geometry effects are influential and should be taken into count when moving towards real engine simulations.

  16. Cracking the perfusion code?: Laser-assisted Indocyanine Green angiography and combined laser Doppler spectrophotometry for intraoperative evaluation of tissue perfusion in autologous breast reconstruction with DIEP or ms-TRAM flaps.

    PubMed

    Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P

    2016-10-01

    The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Vortex Flap Technology: a Stability and Control Assessment

    NASA Technical Reports Server (NTRS)

    Carey, K. M.; Erickson, G. E.

    1984-01-01

    A comprehensive low-speed wind tunnel investigation was performed of leading edge vortex flaps applied to representative aircraft configurations. A determination was made of the effects of analytically- and empirically-designed vortex flaps on the static longitudinal and lateral-directional aerodynamics, stability, and control characteristics of fighter wings having leading-edge sweep angles of 45 to 76.5 degrees. The sensitivity to several configuration modifications was assessed, which included the effects of flap planform, leading- and trailing-edge flap deflection angles, wing location on the fuselage, forebody strakes, canards, and centerline and outboard vertical tails. Six-component forces and moments, wing surface static pressure distributions, and surface flow patterns were obtained using the Northrop 21- by 30-inch low-speed wind tunnel.

  18. Cutaneous haemangiosarcoma of the lower eyelid in an elderly white cat.

    PubMed

    Hartley, Claudia; Ladlow, Jane; Smith, Ken C

    2007-02-01

    A case of cutaneous haemangiosarcoma of the left lower eyelid in a 15-year-old white domestic shorthair cat is reported. A protuberant red mass occupying one-third of the lower eyelid margin length was present. Intermittent haemorrhage occurred from the mass surface. Surgical biopsy had revealed a locally invasive tumour composed of numerous irregular blood-filled spaces lined by a single layer of plump endothelial cells and separated by thin fibrous septa. Mitotic activity was rare and the appearance was consistent with a low-grade haemangiosarcoma. The mass continued to enlarge and referral was sought. Due to financial constraints and the owner's wish for a single procedure, enucleation with an axial pattern flap based on the superficial temporal artery was undertaken. Histopathology of the excised tissue confirmed the presence of a well-differentiated haemangiosarcoma. Tumour-free excisional margins were confirmed, the surgical area healed uneventfully, and there has been no recurrence during the subsequent 16 months.

  19. Superfast high-resolution absolute 3D recovery of a stabilized flapping flight process.

    PubMed

    Li, Beiwen; Zhang, Song

    2017-10-30

    Scientific research of a stabilized flapping flight process (e.g. hovering) has been of great interest to a variety of fields including biology, aerodynamics, and bio-inspired robotics. Different from the current passive photogrammetry based methods, the digital fringe projection (DFP) technique has the capability of performing dense superfast (e.g. kHz) 3D topological reconstructions with the projection of defocused binary patterns, yet it is still a challenge to measure a flapping flight process with the presence of rapid flapping wings. This paper presents a novel absolute 3D reconstruction method for a stabilized flapping flight process. Essentially, the slow motion parts (e.g. body) and the fast-motion parts (e.g. wings) are segmented and separately reconstructed with phase shifting techniques and the Fourier transform, respectively. The topological relations between the wings and the body are utilized to ensure absolute 3D reconstruction. Experiments demonstrate the success of our computational framework by testing a flapping wing robot at different flapping speeds.

  20. A standardized model for predicting flap failure using indocyanine green dye

    NASA Astrophysics Data System (ADS)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  1. Mechanical performance of aquatic rowing and flying.

    PubMed

    Walker, J A; Westneat, M W

    2000-09-22

    Aquatic flight, performed by rowing or flapping fins, wings or limbs, is a primary locomotor mechanism for many animals. We used a computer simulation to compare the mechanical performance of rowing and flapping appendages across a range of speeds. Flapping appendages proved to be more mechanically efficient than rowing appendages at all swimming speeds, suggesting that animals that frequently engage in locomotor behaviours that require energy conservation should employ a flapping stroke. The lower efficiency of rowing appendages across all speeds begs the question of why rowing occurs at all. One answer lies in the ability of rowing fins to generate more thrust than flapping fins during the power stroke. Large forces are necessary for manoeuvring behaviours such as accelerations, turning and braking, which suggests that rowing should be found in slow-swimming animals that frequently manoeuvre. The predictions of the model are supported by observed patterns of behavioural variation among rowing and flapping vertebrates.

  2. Three-dimensional spatiotemporal focusing of holographic patterns

    PubMed Central

    Hernandez, Oscar; Papagiakoumou, Eirini; Tanese, Dimitrii; Fidelin, Kevin; Wyart, Claire; Emiliani, Valentina

    2016-01-01

    Two-photon excitation with temporally focused pulses can be combined with phase-modulation approaches, such as computer-generated holography and generalized phase contrast, to efficiently distribute light into two-dimensional, axially confined, user-defined shapes. Adding lens-phase modulations to 2D-phase holograms enables remote axial pattern displacement as well as simultaneous pattern generation in multiple distinct planes. However, the axial confinement linearly degrades with lateral shape area in previous reports where axially shifted holographic shapes were not temporally focused. Here we report an optical system using two spatial light modulators to independently control transverse- and axial-target light distribution. This approach enables simultaneous axial translation of single or multiple spatiotemporally focused patterns across the sample volume while achieving the axial confinement of temporal focusing. We use the system's capability to photoconvert tens of Kaede-expressing neurons with single-cell resolution in live zebrafish larvae. PMID:27306044

  3. Efficacy of Liposuction as a Delay Method for Improving Flap Survival.

    PubMed

    Orhan, Erkan; Erol, Yağmur Reyyan; Deren, Orgun; Altun, Serdar; Erdoğan, Bülent

    2016-12-01

    Flaps are often used in repairing tissue defects and partial or full flap loss is still an important morbidity cause. Several techniques have been tried to increase flap circulation but none of these could replace the delay technique. Our goal in this study is to show the efficacy of liposuction in delay of dorsal rat cutaneous flaps and improvement in flap survival. Twenty-four Wistar rats were used. The rats in group 1 received 9 × 3-sized caudally-based random pattern skin flaps. In group 2, liposuction was done under the tissue island spotted as the flap and after 14 days, standard flap surgery was done. In group 3, surgical delay was done and after 14 days, standard flap surgery was done. In group 4, liposuction was done under the tissue island spotted as the flap and standard flap surgery was done right after the liposuction. The rate of necrotic tissue in group 3 (surgical delay; mean % 13.7) was less than the rate in group 2 (liposuction delay; mean % 15.1), although the difference was not statistically significant. The necrosis rates in group 3 (surgical delay) and group 2 (liposuction delay) were less than the rates in both group 1 (only flap; mean % 41.5) and group 4 (liposuction flap; mean % 40.0) and this difference was statistically significant (p < 0.0001). Liposuction can be an alternative to surgical delay as a less invasive method in the clinic. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  4. [Vertical rectus abdominis myocutaneous flap for the closure of perineal wound after abdominoperineal resection of the rectum].

    PubMed

    Orhalmi, J; Vreský, B; Holéczy, P; Jackanin, S; Biath, P

    2009-06-01

    A major source of morbidity after abdominoperineal resection (APR) after neoadjuvant external beam pelvic radiation are perineal wound complications. Wound complications are common for 25-66% of patients overall. There are many of procedures provided to reconstruct the perineal defect after APR e.g. primary closure, secondary closure, superior gluteal artery flap and vertical rectus abdominus myocutaneous (VRAM) flap. Our purpose was to describe the effect of VRAM flap on reconstruction of perineal wound. VRAM flaps are ideally suited to bring nonirradiated tissue into defect associated with radical surgical extirpation procedures and irradiated fields. This flap, distally based in the deep inferior epigastric vessels, provides several distinct advantages. It is well perfused by the robust dominant pedicle and the deep inferior epigastric artery and vein. In addition, this flap provides adequate muscle bulk to obliterate pelvic dead space. The skin island can be used for resurfacing the perineal region, including the vaginal wall, and provides versatility for all patterns of resection. VRAM flap provides very good aesthetic and functional results, is technically relatively simple and radically decreases wound complications rate. The additional possibility is pull-through the flap transpelvically intraabdominally instead of pull-through via subcutaneous channel, especially with females.

  5. Analytical model for tilting proprotor aircraft dynamics, including blade torsion and coupled bending modes, and conversion mode operation

    NASA Technical Reports Server (NTRS)

    Johnson, W.

    1974-01-01

    An analytical model is developed for proprotor aircraft dynamics. The rotor model includes coupled flap-lag bending modes, and blade torsion degrees of freedom. The rotor aerodynamic model is generally valid for high and low inflow, and for axial and nonaxial flight. For the rotor support, a cantilever wing is considered; incorporation of a more general support with this rotor model will be a straight-forward matter.

  6. Flow pattern similarities in the near wake of three bird species suggest a common role for unsteady aerodynamic effects in lift generation

    PubMed Central

    Krishnan, Krishnamoorthy; Ben-Gida, Hadar; Kirchhefer, Adam J.; Kopp, Gregory A.; Guglielmo, Christopher G.

    2017-01-01

    Analysis of the aerodynamics of flapping wings has yielded a general understanding of how birds generate lift and thrust during flight. However, the role of unsteady aerodynamics in avian flight due to the flapping motion still holds open questions in respect to performance and efficiency. We studied the flight of three distinctive bird species: western sandpiper (Calidris mauri), European starling (Sturnus vulgaris) and American robin (Turdus migratorius) using long-duration, time-resolved particle image velocimetry, to better characterize and advance our understanding of how birds use unsteady flow features to enhance their aerodynamic performances during flapping flight. We show that during transitions between downstroke and upstroke phases of the wing cycle, the near wake-flow structures vary and generate unique sets of vortices. These structures appear as quadruple layers of concentrated vorticity aligned at an angle with respect to the horizon (named ‘double branch’). They occur where the circulation gradient changes sign, which implies that the forces exerted by the flapping wings of birds are modified during the transition phases. The flow patterns are similar in (non-dimensional) size and magnitude for the different birds suggesting that there are common mechanisms operating during flapping flight across species. These flow patterns occur at the same phase where drag reduction of about 5% per cycle and lift enhancement were observed in our prior studies. We propose that these flow structures should be considered in wake flow models that seek to account for the contribution of unsteady flow to lift and drag. PMID:28163881

  7. A new aeroelastic model for composite rotor blades with straight and swept tips

    NASA Technical Reports Server (NTRS)

    Yuan, Kuo-An; Friedmann, Peretz P.; Venkatesan, Comandur

    1992-01-01

    An analytical model for predicting the aeroelastic behavior of composite rotor blades with straight and swept tips is presented. The blade is modeled by beam type finite elements along the elastic axis. A single finite element is used to model the swept tip. The nonlinear equations of motion for the finite element model are derived using Hamilton's principle and based on a moderate deflection theory and accounts for: arbitrary cross-sectional shape, pretwist, generally anisotropic material behavior, transverse shears and out-of-plane warping. Numerical results illustrating the effects of tip sweep, anhedral and composite ply orientation on blade aeroelastic behavior are presented. Tip sweep can induce aeroelastic instability by flap-twist coupling. Tip anhedral causes lag-torsion and flap-axial couplings, however, its effects on blade stability is less pronounced than the effect due to sweep. Composite ply orientation has a substantial effect on blade stability.

  8. Study of the neovascularisation of prefabrication of flaps using a silicone sheet and an isolated arterial pedicle: experimental study in rabbits.

    PubMed

    Nguyen, The Hoang; Kloeppel, Marcus; Staudenmaier, Rainer; Werner, Jürgen; Biemer, Edgar

    2005-01-01

    Use of an isolated artery as an implanted pedicle in prefabricated flaps has rarely been reported either clinically or experimentally. In Chinchilla Bastard rabbits (n = 36), we dissected an isolated arterial pedicle from the femoral and saphenous artery, anastomosed it end-to-end to the femoral vein at the inguinal ligament and created an isolated arterial loop pedicle. This was implanted and fixed with polyglactin 9/0 under a random-pattern vascularised abdominal fasciocutaneous flap. The neovascularisation in the prefabricated flaps was evaluated macroscopically, by blood analysis, selective microangiography, and histology. The results showed a progressive degree of neovascularisation that corresponded to the increasing length of time that the pedicle was implanted in the flaps. Twenty days after prefabrication, the abdominal fasciocutaneous flap was readily perfused by the blood supply from the arterial pedicle. The capacity of the vessels in this group as seen on angiograms had increased to 258 vessels (108%) compared with the control group (239 vessels, 100%).

  9. The midline central artery forehead flap: a valid alternative to supratrochlear-based forehead flaps.

    PubMed

    Faris, Callum; van der Eerden, Paul; Vuyk, Hade

    2015-01-01

    This study clarifies the pedicle geometry and vascular supply of a midline forehead flap for nasal reconstruction. It reports on the vascular reliability of this flap and its ability to reduce hair transposition to the nose, a major complicating factor of previous forehead flap designs. To compare the vascular reliability of 3 different pedicle designs of the forehead flap in nasal reconstruction (classic paramedian, glabellar paramedian, and central artery flap design) and evaluate hair transposition rates and aesthetic results. Retrospective analysis of patient data and outcomes retrieved from computer files generated at the time of surgery, supplemented by data from the patient medical records and photographic documentation, from a tertiary referral nasal reconstructive practice, within a secondary-care hospital setting. The study population included all consecutive patients over a 19-year period who underwent primary forehead flap repair of nasal defects, with more than 3 months of postoperative follow-up and photographic documentation. Three sequential forehead flap patterns were used (classic paramedian flap, glabella flap, and central artery flap) for nasal reconstruction over the study duration. Data collected included patient characteristics, method of repair, complications, functional outcome, and patient satisfaction score. For cosmetic outcome, photographic documentation was scored by a medical juror. No forehead flap had vascular compromise in the first stage. Partial flap necrosis was reported in subsequent stages in 4 patients (1%), with no statistical difference in the rate of vascular compromise between the 3 flap designs. Hair transposition to the nose was lower in the central artery forehead flap (7%) compared with the classic paramedian (23%) and glabellar paramedian (13%) flaps (P < .05). Photographic evaluation in 227 patients showed that brow position (98%) and color match (83%) were good in the majority of the patients. In this series, the central artery forehead flap was as reliable (in terms of vascularity) as the glabellar and classic paramedian forehead flap. Its use resulted in a statistically significant reduction in transfer of hair to the nose in our series. 3.

  10. Perforator chimerism for the reconstruction of complex defects: A new chimeric free flap classification system.

    PubMed

    Kim, Jeong Tae; Kim, Youn Hwan; Ghanem, Ali M

    2015-11-01

    Complex defects present structural and functional challenges to reconstructive surgeons. When compared to multiple free flaps or staged reconstruction, the use of chimeric flaps to reconstruct such defects have many advantages such as reduced number of operative procedures and donor site morbidity as well as preservation of recipient vessels. With increased popularity of perforator flaps, chimeric flaps' harvest and design has benefited from 'perforator concept' towards more versatile and better reconstruction solutions. This article discusses perforator based chimeric flaps and presents a practice based classification system that incorporates the perforator flap concept into "Perforator Chimerism". The authors analyzed a variety of chimeric patterns used in 31 consecutive cases to present illustrative case series and their new classification system. Accordingly, chimeric flaps are classified into four types. Type I: Classical Chimerism, Type II: Anastomotic Chimerism, Type III: Perforator Chimerism and Type IV Mixed Chimerism. Types I on specific source vessel anatomy whilst Type II requires microvascular anastomosis to create the chimeric reconstructive solution. Type III chimeric flaps utilizes the perforator concept to raise two components of tissues without microvascular anastomosis between them. Type IV chimeric flaps are mixed type flaps comprising any combination of Types I to III. Incorporation of the perforator concept in planning and designing chimeric flaps has allowed safe, effective and aesthetically superior reconstruction of complex defects. The new classification system aids reconstructive surgeons and trainees to understand chimeric flaps design, facilitating effective incorporation of this important reconstructive technique into the armamentarium of the reconstruction toolbox. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Investigation of Severe Craniomaxillofacial Battle Injuries Sustained by U.S. Service Members: A Case Series

    DTIC Science & Technology

    2012-11-05

    advancement flaps and reconstructive advancement of lower lip and a buccal mucosa advancement flap to reconstruct maxillary lip. (C) Incision markings for...Maxillofac Surg 2007;65:1215 1218 6 Clark N, Birely B, Manson PN, et al. High energy ballistic and avulsive facial injuries: classification, patterns, and

  12. Opened end-to-side technique for end-to-side anastomosis and analyses by an elastic true-to-scale silicone rubber model.

    PubMed

    Mücke, Thomas; Ritschl, Lucas M; Balasso, Andrea; Wolff, Klaus-Dietrich; Mitchell, David A; Liepsch, Dieter

    2014-01-01

    The end-to-side anastomosis is frequently used in microvascular free flap transfer, but detailed rheological analyses are not available. The purpose of this study was to introduce a new modified end-to-side (Opened End-to-Side, OES-) technique and compare the resulting flow pattern to a conventional technique. The new technique was based on a bi-triangulated preparation of the branching-vessel end, resulting in a "fish-mouthed" opening. We performed two different types of end-to-side anastomoses in forty pig coronary arteries and produced one elastic, true-to-scale silicone rubber model of each anastomosis. Then we installed the transparent models in a circulatory experimental setup that simulated the physiological human blood flow. Flow velocity was measured with the one-component Laser-Doppler-Anemometer system, recording flow axial and perpendicular to the model at four defined cross-sections for seven heart cycles in each model. Maximal and minimal axial velocities ranged in the conventional model between 0.269 and -0.122 m/s and in the experimental model between 0.313 and -0.153 m/s. A less disturbed flow velocity distribution was seen in the experimental model distal to the anastomosis. The OES-technique showed superior flow profiles distal to the anastomosis with minor tendencies of flow separation and represents a new alternative for end-to-side anastomosis. Copyright © 2013 Wiley Periodicals, Inc.

  13. Measurements of noise produced by flow past lifting surfaces

    NASA Technical Reports Server (NTRS)

    Kendall, J. M.

    1978-01-01

    Wind tunnel studies have been conducted to determine the specific locations of aerodynamic noise production within the flow field about various lifting-surface configurations. The models tested included low aspect ratio shapes intended to represent aircraft flaps, a finite aspect ratio NACA 0012 wing, and a multi-element wing section consisting of a main section, a leading edge flap, and dual trailing edge flaps. Turbulence was induced on the models by surface roughness. Lift and drag were measured for the flap models. Hot-wire anemometry was used for study of the flap-model vortex roll-up. Apparent noise source distributions were measured by use of a directional microphone system, located outside the tunnel, which was scanned about the flow region to be analyzed under computer control. These distributions exhibited a diversity of pattern, suggesting that several flow processes are important to lifting-surface noise production. Speculation concerning these processes is offered.

  14. Acute effects of cigarette smoke exposure on experimental skin flaps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nolan, J.; Jenkins, R.A.; Kurihara, K.

    1985-04-01

    Random vascular patterned caudally based McFarlane-type skin flaps were elevated in groups of Fischer 344 rats. Groups of rats were then acutely exposed on an intermittent basis to smoke generated from well-characterized research filter cigarettes. Previously developed smoke inhalation exposure protocols were employed using a Maddox-ORNL inhalation exposure system. Rats that continued smoke exposure following surgery showed a significantly greater mean percent area of flap necrosis compared with sham-exposed groups or control groups not exposed. The possible pathogenesis of this observation as well as considerations and correlations with chronic human smokers are discussed. Increased risks of flap necrosis by smokingmore » in the perioperative period are suggested by this study.« less

  15. [Locoregional solutions for groin defects : Coverage after vascular surgery].

    PubMed

    Cerny, M; Harder, Y; Zimmermann, A; Eckstein, H-H; Machens, H-G; Schantz, J-T; Schenck, T L

    2017-01-01

    Vascular surgery through a groin incision may be associated with severe wound healing disorders in this sensitive area. There are many options to reconstruct the defect surgically. The choice of surgical reconstruction depends mainly on the individual status of vasculature, which is most often compromised in these patients. There are random pattern flaps, as well as perforator, pedicled flaps or microvascular flaps to choose from. We give an overview of plastic surgical solutions for groin defects, with a special focus on complex wounds after vascular surgical complications. We discuss advantages and disadvantages of different flaps with two case reports and also show alternatives. We demonstrate in two cases how the reconstruction of the groin defect was planned, taking into account the vascular status, and why we chose an innovative and seldom-used option in each case. The selected flaps, a pedicled fasciocutaneous ALT propeller flap and a perforator-based, pedicled abdominal advancement flap reconstructed the defects successfully. The surgical therapy for the reconstruction of groin defects should be chosen according to the individual vascular status to ensure safe and reliable blood supply. To guarantee the best possible reconstruction and avoid postoperative healing disorders and infections, less common flaps should also be considered.

  16. Effect of Electroacupuncture at The Zusanli Point (Stomach-36) on Dorsal Random Pattern Skin Flap Survival in a Rat Model.

    PubMed

    Wang, Li-Ren; Cai, Le-Yi; Lin, Ding-Sheng; Cao, Bin; Li, Zhi-Jie

    2017-10-01

    Random skin flaps are commonly used for wound repair and reconstruction. Electroacupuncture at The Zusanli point could enhance microcirculation and blood perfusion in random skin flaps. To determine whether electroacupuncture at The Zusanli point can improve the survival of random skin flaps in a rat model. Thirty-six male Sprague Dawley rats were randomly divided into 3 groups: control group (no electroacupuncture), Group A (electroacupuncture at a nonacupoint near The Zusanli point), and Group B (electroacupuncture at The Zusanli point). McFarlane flaps were established. On postoperative Day 2, malondialdehyde (MDA) and superoxide dismutase were detected. The flap survival rate was evaluated, inflammation was examined in hematoxylin and eosin-stained slices, and the expression of vascular endothelial growth factor (VEGF) was measured immunohistochemically on Day 7. The mean survival area of the flaps in Group B was significantly larger than that in the control group and Group A. Superoxide dismutase activity and VEGF expression level were significantly higher in Group B than those in the control group and Group A, whereas MDA and inflammation levels in Group B were significantly lower than those in the other 2 groups. Electroacupuncture at The Zusanli point can effectively improve the random flap survival.

  17. Naringin improves random skin flap survival in rats.

    PubMed

    Cheng, Liang; Chen, Tingxiang; Tu, Qiming; Li, Hang; Feng, Zhenghua; Li, Zhijie; Lin, Dingsheng

    2017-11-07

    Random-pattern flap transfer is commonly used to treat soft-tissue defects. However, flap necrosis remains a serious problem. Naringin accelerates angiogenesis by activating the expression of vascular endothelial growth factor (VEGF). In the present study, we investigated whether naringin improves the survival of random skin flaps. Compared with controls, the naringin-treated groups exhibited significantly larger mean areas of flap survival, significantly increased SOD activity and VEGF expression, and significantly reduced MDA level. Hematoxylin and eosin (HE) staining revealed that naringin promoted angiogenesis and inhibited inflammation. "McFarlane flap" models were established in 90 male Sprague-Dawley (SD) rats divided into three groups: a 40 mg/kg control group (0.5 % sodium carboxymethylcellulose), a 40 mg/kg naringin-treated group, and an 80 mg/kg naringin-treated group. The extent of necrosis was measured 7 days later, and tissue samples were subjected to histological analysis. Angiogenesis was evaluated via lead oxide-gelatin angiography, immunohistochemistry, and laser Doppler imaging. Inflammation was evaluated by measurement of serum TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) levels. Oxidative stress was assessed by measuring superoxide dismutase (SOD) activity and the malondialdehyde (MDA) level. Naringin improved random skin flap survival.

  18. Sound-diffracting flap in the ear of a bat generates spatial information.

    PubMed

    Müller, Rolf; Lu, Hongwang; Buck, John R

    2008-03-14

    Sound diffraction by the mammalian ear generates source-direction information. We have obtained an immediate quantification of this information from numerical predictions. We demonstrate the power of our approach by showing that a small flap in a bat's pinna generates useful information over a large set of directions in a central band of frequencies: presence of the flap more than doubled the solid angle with direction information above a given threshold. From the workings of the employed information measure, the Cramér-Rao lower bound, we can explain how physical shape is linked to sensory information via a strong sidelobe with frequency-dependent orientation in the directivity pattern. This method could be applied to any other mammal species with pinnae to quantify the relative importance of pinna structures' contributions to directional information and to facilitate interspecific comparisons of pinna directivity patterns.

  19. Computation of spanwise distribution of circulation and lift coefficient for flapped wings of arbitrary planform

    NASA Technical Reports Server (NTRS)

    Razak, K.

    1980-01-01

    The question of the effect of distribution and magnitude of spanwise circulation and shed vorticity from an airplane wing on the distribution pattern of agricultural products distributed from an airplane was studied. The first step in an analysis of this question is the determination of the actual distribution of lift along an airplane wing, from which the pattern of shed vorticity can be determined. A procedure is developed to calculate the span loading for flapped and unflapped wings of arbitrary aspect ratio and taper ratio. The procedure was programmed on a small programmable calculator, the Hewlett Packard HP-97, and also was programmed in BASIC language. They could be used to explore the variations in span loading that can be secured by variable flap deflections or the effect of flying at varying air speeds at different airplane gross weights. Either an absolute evaluation of span loading can be secured or comparative span loading can be evaluated to determine their effect on swath width and swath distribution pattern. The programs are intended to assist the user in evaluating the effect of a given spanload distribution.

  20. 4D metrology of flapping-wing micro air vehicle based on fringe projection

    NASA Astrophysics Data System (ADS)

    Zhang, Qican; Huang, Lei; Chin, Yao-Wei; Keong, Lau-Gih; Asundi, Anand

    2013-06-01

    Inspired by dominant flight of the natural flyers and driven by civilian and military purposes, micro air vehicle (MAV) has been developed so far by passive wing control but still pales in aerodynamic performance. Better understanding of flapping wing flight mechanism is eager to improve MAV's flight performance. In this paper, a simple and effective 4D metrology technique to measure full-field deformation of flapping membrane wing is presented. Based on fringe projection and 3D Fourier analysis, the fast and complex dynamic deformation, including wing rotation and wing stroke, of a flapping wing during its flight can be accurately reconstructed from the deformed fringe patterns recorded by a highspeed camera. An experiment was carried on a flapping-wing MAV with 5-cm span membrane wing beating at 30 Hz, and the results show that this method is effective and will be useful to the aerodynamicist or micro aircraft designer for visualizing high-speed complex wing deformation and consequently aid the design of flapping wing mechanism to enhanced aerodynamic performance.

  1. The Role of the Distal Runoff Vessel of the Descending Branch of the Lateral Circumflex Femoral System in Anterolateral Thigh Flap Surgery: A Case Series and Literature Review.

    PubMed

    He, Xiao-Qing; Zhu, Yue-Liang; Wang, Yi; Mei, Liang-Bin; Jin, Tao; Xu, Yong-Qing

    2016-01-01

    As a distal portion of the descending branch of the lateral circumflex femoral system (LCFS), the role of the distal runoff vessel in anterolateral thigh (ALT) flap surgery has long been overlooked. Recently, however, the distal runoff vessel has been increasingly used in many aspects of ALT flap surgery, and it has exhibited superior properties in solving some difficult problems. Fourteen ALT flaps using the distal runoff vessel of the descending branch of the LCFS for extremity defects were retrospectively reviewed, and recent reports on using the distal runoff vessel were reviewed to determine the role of this vessel in ALT flap surgery. In our series, the distal runoff vessel was used as a flow-through pattern in 10 cases, as a recombined chimeric flap in 2 cases, and as a backup vessel for flap salvage in 2 cases. All of the ALT flaps completely survived. None of the donor sites presented with additional morbidity as a result of harvesting the distal runoff vessel. In the literature review, the following are 5 other options for using the distal runoff vessel: in interposition artery and vein grafts, as the pedicle of the reverse-flow ALT flap, as the recipient vessel, to avoid twisting, and as a monitoring method. The distal runoff vessel of the descending branch of the LCFS could be used for many aspects of the ALT flap surgery, and this vessel plays an irreplaceable role in some difficult reconstruction surgeries.

  2. Flap preconditioning by pressure-controlled cupping in a rat model.

    PubMed

    Koh, Kyung S; Park, Sung Woo; Oh, Tae Suk; Choi, Jong Woo

    2016-08-01

    Flap survival is essential for the success of soft-tissue reconstruction. Accordingly, various surgical and medical methods aim to increase flap survival. Because flap survival is affected by the innate vascular supply, traditional preconditioning methods mainly target vasodilatation or vascular reorientation to increase blood flow to the tissue. External stress on the skin, such as an external volume expander or cupping, induces vascular remodeling, and these approaches have been used in the fat grafting field and in traditional Asian medicine. In the present study, we used a rat random-pattern dorsal flap model to study the effectiveness of preconditioning with an externally applied device (cupping) at the flap site that directly applied negative pressure to the skin. The device, the pressure-controlled cupping, is connected to negative pressure vacuum device providing accurate pressure control from 0 mm Hg to -200 mm Hg. Flap surgery was performed after preconditioning under -25 mm Hg suction pressure for 30 min a day for 5 d, followed by 9 d of postoperative observation. Flap survival was assessed as the area of viable tissue and was compared between the preconditioned group and a control group. The preconditioned group showed absolute percentage increase of flap viability relative to the entire flap by 19.0± 7.6% (average 70.1% versus 51.0%). Tissue perfusion of entire flap, evaluated by laser Doppler imaging system, was improved with absolute percentage increase by 24.2± 10.4% (average 77.4% versus 53.1%). Histologic analysis of hematoxylin and eosin, CD31, and Masson-trichrome staining showed increased vascular density in the subdermal plexus and more organized collagen production with hypertrophy of the attached muscle. Our study suggests that flap preconditioning caused by controlled noninvasive suction induces vascular remodeling that increases tissue perfusion and improves flap survival in a rat model. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Combined use of tri-axial accelerometers and GPS reveals the flexible foraging strategy of a bird in relation to weather conditions

    PubMed Central

    Rodríguez, Carlos; Dell’Omo, Giacomo; Bustamante, Javier

    2017-01-01

    Tri-axial accelerometry has proved to be a useful technique to study animal behavior with little direct observation, and also an effective way to measure energy expenditure, allowing a refreshing revisit to optimal foraging theory. This theory predicts that individuals should gain the most energy for the lowest cost in terms of time and energy when foraging, in order to maximize their fitness. However, during a foraging trip, central-place foragers could face different trade-offs during the commuting and searching parts of the trip, influencing behavioral decisions. Using the lesser kestrel (Falco naumanni) as an example we study the time and energy costs of different behaviors during the commuting and searching parts of a foraging trip. Lesser kestrels are small insectivorous falcons that behave as central-place foragers during the breeding season. They can commute by adopting either time-saving flapping flights or energy-saving soaring-gliding flights, and capture prey by using either time-saving active hovering flights or energy-saving perch-hunting. We tracked 6 lesser kestrels using GPS and tri-axial accelerometers during the breeding season. Our results indicate that males devoted more time and energy to flight behaviors than females in agreement with being the sex responsible for food provisioning to the nest. During the commuting flights, kestrels replaced flapping with soaring-gliding flights as solar radiation increased and thermal updrafts got stronger. In the searching part, they replaced perch-hunting with hovering as wind speed increased and they experienced a stronger lift. But also, they increased the use of hovering as air temperature increased, which has a positive influence on the activity level of the preferred prey (large grasshoppers). Kestrels maintained a constant energy expenditure per foraging trip, although flight and hunting strategies changed dramatically with weather conditions, suggesting a fixed energy budget per trip to which they adjusted their commuting and searching strategies in response to weather conditions. PMID:28591181

  4. Model of an axially strained weakly guiding optical fiber modal pattern

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O.; Rogowski, Robert S.

    1992-01-01

    Axial strain can be determined by monitoring the modal pattern variation of an optical fiber. The results of a numerical model developed to calculate the modal pattern variation at the end of a weakly guiding optical fiber under axial strain is presented. Whenever an optical fiber is under stress, the optical path length, the index of refraction, and the propagation constants of each fiber mode change. In consequence, the modal phase term for the fields and the fiber output pattern are also modified. For multimode fibers, very complicated patterns result. The predicted patterns are presented, and an expression for the phase variation with strain is derived.

  5. SSME Seal Test Program: Test results for sawtooth pattern damper seal

    NASA Technical Reports Server (NTRS)

    Childs, D. W.

    1986-01-01

    Direct and transverse force coefficients for 11, sawtooth-pattern, and damper-seal configurations were examined. The designation damper seal uses a deliberately roughened stator and smooth rotor to increase the net damping force developed by a seal. The designation sawtooth-pattern refers to a stator roughness pattern. The sawtooth pattern yields axial grooves in the stator which are interrupted by spacer elements which act as flow constrictions or dams. All seals use the same smooth rotor and have the same, constant, minimum clearance. The stators examined the consequences of changes in the following design parameters: (1) axial-groove depth; (2) number of teeth: (3) number of sawtooth sections; (4) number of spacer elements; (5) dam width; (6) axially aligned sawtooth sections versus axially-staggered sawtooth sections; and (7) groove geometry. It is found that none of the sawtooth-pattern seal performs as well as the best round-hole-pattern seal. Maximum damping configurations for the sawtooth and round-hole-pattern stators have comparable stiffness performance. Several of the sawtooth pattern stators outperformed the best round-hole pattern seal.

  6. Use of Systemic Rosmarinus Officinalis to Enhance the Survival of Random-Pattern Skin Flaps

    PubMed Central

    İnce, Bilsev; Bilgen, Fatma; Gündeşlioğlu, Ayşe Özlem; Dadacı, Mehmet; Kozacıoğlu, Sümeyye

    2016-01-01

    Background Skin flaps are commonly used in soft-tissue reconstruction; however, necrosis can be a frequent complication. Several systemic and local agents have been used in attempts to improve skin flap survival, but none that can prevent flap necrosis have been identified. Aims This study aims to determine whether the use of systemic Rosmarinus officinalis (R. officinalis) extract can prevent flap necrosis and improve skin flap recovery. Study Design Animal experimentation. Methods Thirty-five Wistar albino rats were divided in five groups. A rectangular random-pattern flaps measuring 8×2 cm was elevated from the back of each rat. Group I was the control group. In Group II, 0.2 ml of R. officinalis oil was given orally 2h before surgery. R. officinalis oil was then applied orally twice a day for a week. In Group III, R. officinalis oil was given orally twice a day for one week before surgery. At the end of the week, 0.2 mL of R. officinalis oil was given orally 2 h before surgery. In Group IV, 0.2 mL of R. officinalis oil was injected subcutaneously 2 h before surgery. After the surgery, 0.2 mL R. officinalis oil was injected subcutaneously twice a day for one week. In Group V, 0.2 mL R. officinalis oil was injected subcutaneously twice a day for one week prior to surgery. At the end of the week, one last 0.2 mL R. officinalis oil injection was administered subcutaneously 2 h before surgery. After the surgery, 0.2 mL R. officinalis oil was injected subcutaneously twice a day for one week. Results The mean percentage of viable surface area was significantly greater (p<0.05) in Groups II, III, IV, and V as compared to Group I. Mean vessel diameter was significantly greater (p<0.05) in Groups II, III, IV, and V as compared to Group I. Conclusion We have determined that, in addition to its anti-inflammatory and anti-oxidant effects, R. officinalis has vasodilatory effects that contribute to increased skin flap survival. PMID:27994918

  7. Numerical investigation of the aerodynamic loads and hinge moments of the flap with boundary layer control

    NASA Astrophysics Data System (ADS)

    Pavlenko, Olga V.; Pigusov, Evgeny A.

    2018-05-01

    The paper discusses the approach of numerical simulation of the boundary layer control (BLC) on deflected flap for suppression of flow separation. Computational investigations were carried out using a program based on numerically solving the Reynolds averaged Navier-Stokes equations. The aim of this work is numerical investigation of the aerodynamic loads and hinge moments of the flap with BLC with influence of the walls of the wind tunnel. We have made a calculation of the airfoil section with flap deflected by 20° and 60° with variation of blowing momentum coefficient of Cμ=0÷0.1. The comparison of the calculation results with the experimental values of lift coefficient, pitching moment and pressure coefficient is presented. The pressure distribution on all surface of the wing and the threedimensional flow pattern of the wing with BLC, influence of the walls of the wind tunnel and the aerodynamic loads and hinge moments of the BLC flap are given. It is shown that the 20° flap increases the jet momentum coefficient from Cμ=0 to Cμ=0.1, leads to an increase of the hinge moment coefficient almost in 2 times, and the 60° flap increases the jet momentum coefficient from Cμ=0 to Cμ=0.113, leads to an increase of the hinge moment coefficient almost 3.5 times. The magnitude of the hinge moment on the flap with BLC rises due to the increase of the total aerodynamic force acting on the flap. As a result, the jet blowing on the plain flap leads to the significant increase of the hinge moment that must be considered when designing the high-lift devices with BLC.

  8. Reconstruction with latissimus dorsi, external abdominal oblique and cranial sartorius muscle flaps for a large defect of abdominal wall in a dog after surgical removal of infiltrative lipoma

    PubMed Central

    FENG, Yu-Ching; CHEN, Kuan-Sheng; CHANG, Shih-Chieh

    2016-01-01

    This animal was presented with a large-sized infiltrative lipoma in the abdominal wall that had been noted for 4 years. This lipoma was confirmed by histological examination from a previous biopsy, and the infiltrative features were identified by a computerized tomography scan. The surgical removal created a large-sized abdominal defect that was closed by a combination of latissimus dorsi and external abdominal oblique muscle flaps in a pedicle pattern. A small dehiscence at the most distal end of the muscle flap resulted in a small-sized abdominal hernia and was repaired with cranial sartorius muscle flap 14 days after surgery. The dog was in good general health with no signs of tumor recurrence after 18 months of follow-up. PMID:27476526

  9. Light meromyosin paracrystal formation.

    PubMed

    Chowrashi, P K; Pepe, F A

    1977-07-01

    STUDIES OF PARACRYSTAL FORMATION BY COLUMN PURIFIED LIGHT MEROMYOSIN (LMM) PREPARED IN A VARIETY OF WAYS LED TO THE FOLLOWING CONCLUSIONS: (a) different portions of the myosin rod may be coded for different stagger relationships. This was concluded from observations that paracrystals with different axial repeat periodicities could be obtained either with LMM framents of different lengths prepared with the same enzyme, or with LMM fragments of identical lengths but prepared with different enzymes. (b) Paracrystals with a 14-nm axial repeat periodicity are most likely formed by the aggregation of sheets with a 44-nm axial repeat within the sheets which are staggered by 14 nm. All of the axial repeat patterns expected from one sheet or aggregates of more than one sheet, on this basis, were observed in the same electron micrograph. (c) C-protein binding probably occurs preferentially to LMM molecules related in some specific way. This was concluded from the observation that the same axial repeat pattern was obtained in paracrystals formed from different LMM preparations in the presence of C-protein, regardless of differences in the axial repeat obtained in the absence of C-protein. (d) Nucleic acid is responsible for the 43-nm axial repeat patterns observed in paracrystals formed by the ethanol-resistant fraction of LMM. In the absence of nuclei acid, paracrystals with a 14nm axial repeat are obtained. (e) The 43-nm axial repeat pattern observed with the ethanol-resistant fraction of LMM is different for LMM preparations obtained by trypsin and papain digestions.

  10. Near-infrared spectroscopic assessment of oxygen delivery to free flaps on monkeys following vascular occlusions and inhalation of pure oxygen

    NASA Astrophysics Data System (ADS)

    Tian, Fenghua; Ding, Haishu; Cai, Zhigang; Wang, Guangzhi; Zhao, Fuyun

    2002-04-01

    In recent studies, near-infrared spectroscopy (NIRS) has been considered as a potentially ideal noninvasive technique for the postoperative monitoring of plastic surgery. In this study, free flaps were raised on rhesus monkeys' forearms and oxygen delivery to these flaps was monitored following vascular occlusions and inhalation of pure oxygen. Optical fibers were adopted in the probe of the oximeter so that the detection could be performed in reflectance mode. The distance between emitter and detector can be adjusted easily to achieve the best efficacy. Different and repeatable patterns of changes were measured following vascular occlusions (arterial occlusion, venous occlusion and total occlusion) on flaps. It is clear that the near-infrared spectroscopy is capable of postoperatively monitoring vascular problems in flaps. NIRS showed high sensitivity to detect the dynamic changes in flaps induced by inhalation of pure oxygen in this study. The experimental results indicated that it was potential to assess tissue viability utilizing the dynamic changes induced by a noninvasive stimulation. It may be a new assessing method that is rapid, little influenced by other factors and brings less discomfort to patients.

  11. Model of an axially strained weakly guiding optical fiber modal pattern

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O.; Rogowski, Robert S.

    1991-01-01

    Axial strain may be determined by monitoring the modal pattern variation of an optical fiber. In this paper we present the results of a numerical model that has been developed to calculate the modal pattern variation at the end of a weakly guiding optical fiber under axial strain. Whenever an optical fiber is under stress, the optical path length, the index of refraction and the propagation constants of each fiber mode change. In consequence, the modal phase term of the fields and the fiber output pattern are also modified. For multimode fibers, very complicated patterns result. The predicted patterns are presented, and an expression for the phase variation with strain is derived.

  12. Skin sparing/skin reducing mastectomy (SSM/SRM) and the concept of oncoplastic breast surgery.

    PubMed

    Atiyeh, Bishara; Dibo, Saad; Zgheib, Elias; Abbas, Jaber

    2014-10-01

    With the better understanding of breast cancer history and biology, improved diagnostic modalities and the shift towards minimally invasive surgeries, indications for prophylactic mastectomy, skin sparing or skin reducing mastectomies (SSM/SRM) with nipple areolar complex (NAC) preservation coupled with immediate breast reconstruction are gaining popularity. The authors share their experience and conception with mastectomy and immediate alloplastic breast reconstruction with the esthetic circumvertical mammoplasty pattern combined with the dermal barrier buttress flap. The described technique was performed for 28 patients presenting for mastectomy and immediate alloplastic breast reconstruction. With close collaboration between the oncologic and plastic surgeons, mastectomy was performed in all cases with the esthetic circumvertical mammoplasty pattern. To achieve safe excision and optimal reconstruction, the standard incisions could be custom designed to fit oncologic requirements and allow the creation of a dermal barrier flap used as a buttress separating the implant from the suture line. The circumvertical mastectomy pattern combined with the dermal barrier buttress flap is a versatile option allowing safe reconstruction regardless of the tumor and necessary skin excision location. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Efficiency of lift production in flapping and gliding flight of swifts.

    PubMed

    Henningsson, Per; Hedenström, Anders; Bomphrey, Richard J

    2014-01-01

    Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord) and/or twist from root to tip (reducing local angle of attack). We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag.

  14. A new agent for flap survival – Hippophae rhamnoides L. (sea buckthorn): An experimental study in rats

    PubMed Central

    Emsen, Ilteris Murat

    2005-01-01

    Hippophae rhamnoides L. (sea buckthorn) is a member of the Elaeagnaceae family, and is a temperate bush native to Europe and Asia. The antioxidant activity of H rhamnoides L. has been shown in vitro cell culture and animal studies. Different fractions of H rhamnoides L. fruits inhibit 2,2-azobis-(2,4 dimethylvaleronitrile) and ascorbate iron-induced lipid peroxidations in vitro. H rhamnoides L., as well as vitamin E, decrease the malondialdehyde content in hyperlipidemic rabbit serum-cultured smooth muscle cells. The aim of the present study was to investigate, in a rat model, the potential effect of H rhamnoides L. on survival of random pattern skin flaps. For this purpose, 30 Wistar Albino rats were used, and a McFarlane-type caudally based skin flap was created on the dorsum of the rat (2.5 cm × 8 cm). Rats were divided into three groups: one control (group A) and two treatment groups (groups B and C). H rhamnoides L. was administered orally to the experimental groups: group B received a single 15 mg/kg dose per day and group C received 15 mg/kg twice per day. The areas and lengths of flap necrosis were measured in each group. The extent of necrotic flap areas were evaluated as length and area of total flap area, and differences were studied by Student’s t tests. The areas and lengths of necrosis of skin flaps decreased depending on H rhamnoides L., but viability of the flaps treated with 15 mg/kg/day was not significantly different from the control group. The rats receiving H rhamnoides L. 15 mg/kg twice per day had the highest flap survival rate (P<0.001). In conclusion, H rhamnoides L. may have a dose-dependent effect to increase flap survival in random skin flaps. PMID:24227931

  15. Efficiency of Lift Production in Flapping and Gliding Flight of Swifts

    PubMed Central

    Henningsson, Per; Hedenström, Anders; Bomphrey, Richard J.

    2014-01-01

    Many flying animals use both flapping and gliding flight as part of their routine behaviour. These two kinematic patterns impose conflicting requirements on wing design for aerodynamic efficiency and, in the absence of extreme morphing, wings cannot be optimised for both flight modes. In gliding flight, the wing experiences uniform incident flow and the optimal shape is a high aspect ratio wing with an elliptical planform. In flapping flight, on the other hand, the wing tip travels faster than the root, creating a spanwise velocity gradient. To compensate, the optimal wing shape should taper towards the tip (reducing the local chord) and/or twist from root to tip (reducing local angle of attack). We hypothesised that, if a bird is limited in its ability to morph its wings and adapt its wing shape to suit both flight modes, then a preference towards flapping flight optimization will be expected since this is the most energetically demanding flight mode. We tested this by studying a well-known flap-gliding species, the common swift, by measuring the wakes generated by two birds, one in gliding and one in flapping flight in a wind tunnel. We calculated span efficiency, the efficiency of lift production, and found that the flapping swift had consistently higher span efficiency than the gliding swift. This supports our hypothesis and suggests that even though swifts have been shown previously to increase their lift-to-drag ratio substantially when gliding, the wing morphology is tuned to be more aerodynamically efficient in generating lift during flapping. Since body drag can be assumed to be similar for both flapping and gliding, it follows that the higher total drag in flapping flight compared with gliding flight is primarily a consequence of an increase in wing profile drag due to the flapping motion, exceeding the reduction in induced drag. PMID:24587260

  16. [Effects of combined natural hirudin and hyperbaric oxygen therapy on survival of transplanted random-pattern skin flap in rats].

    PubMed

    Cai, Jieyun; Lin, Bojie; Pan, Xinyuan; Cui, Jia; Pradhan, Rohan; Yin, Guoqian

    2018-04-01

    To investigate the effect of natural hirudin combined with hyperbaric oxygen therapy on the survival of transplanted random-pattern skin flap in rats. A random-pattern skin flap in size of 10.0 cm×2.5 cm was elevated on the dorsum of 72 Sprague Dawley rats. Then the 72 rats were randomly divided into 4 groups ( n =18) according to the therapy method. At immediate and within 4 days after operation, the rats were treated with normal saline injection in control group, normal saline injection combined with hyperbaric oxygen treatment in hyperbaric oxygen group, the natural hirudin injection in natural hirudin group, and the natural hirudin injection combined with hyperbaric oxygen treatment in combined group. The flap survival was observed after operation, and survival rate was evaluated at 6 days after operation. The skin samples were collected for histological analysis, microvessel density (MVD) measurement, and evaluation of tumor necrosis factor α (TNF-α) expression level by the immunohistochemical staining at 2 and 4 days after operation. Partial necrosis occurred in each group after operation, and the flap in combined group had the best survival. The survival rate of flap was significantly higher in hyperbaric oxygen group, natural hirudin group, and combined group than that in control group, and in combined group than in hyperbaric oxygen group and natural hirudin group ( P <0.05). There was no significant difference between hyperbaric oxygen group and natural hirudin group ( P >0.05). At 2 days, more microvascular structure was observed in hyperbaric oxygen group, natural hirudin group, and combined group in comparison with control group; while plenty of inflammatory cells infiltration in all groups. At 4 days, the hyperbaric oxygen group, natural hirudin group, and the combined group still showed more angiogenesis. Meanwhile, there was still infiltration of inflammatory cells in control group, inflammatory cells in the other groups were significantly reduced when compared with at 2 days. At 2 days, the MVD was significantly higher in hyperbaric oxygen group, natural hirudin group, and combined group than that in control group ( P <0.05); the expression of TNF-α was significantly lower in hyperbaric oxygen group, natural hirudin group, and combined group than that in control group ( P <0.05). There was no significant difference in above indexes between hyperbaric oxygen group, natural hirudin group, and combined group ( P >0.05). At 4 days, the MVD was significantly higher in hyperbaric oxygen group, natural hirudin group, and combined group than that in control group, in natural hirudin group and combined group than in hyperbaric oxygen group ( P <0.05). The expression of TNF-α was significantly lower in hyperbaric oxygen group, natural hirudin group, and combined group than that in control group, in combined group than in natural hirudin group and hyperbaric oxygen group ( P <0.05). Hyperbaric oxygen and natural hirudin therapy after random-pattern skin flap transplantation can improve the survival of flaps. Moreover, combined therapy is seen to exhibit significant synergistic effect. This effect maybe related to promotion of angiogenesis and the reduction of inflammation response.

  17. The importance of being top-heavy: Intrinsic stability of flapping flight

    NASA Astrophysics Data System (ADS)

    Ristroph, Leif; Liu, Bin; Zhang, Jun

    2011-11-01

    We explore the stability of flapping flight in a model system that consists of a pyramid-shaped object that freely hovers in a vertically oscillating airflow. Such a ``bug'' not only generates sufficient aerodynamic force to keep aloft but also robustly maintains balance during free-flight. Flow visualization reveals that both weight support and intrinsic stability result from the periodic shedding of dipolar vortices. Counter-intuitively, the observed pattern of vortex shedding suggests that stability requires a high center-of-mass, which we verify by comparing the performance of top- and bottom-heavy bugs. Finally, we visit a zoo of other flapping flyers, including Mary Poppins' umbrella, a flying saucer or UFO, and Da Vinci's helicopter.

  18. Segmentation of the zebrafish axial skeleton relies on notochord sheath cells and not on the segmentation clock

    PubMed Central

    Lleras Forero, Laura; Narayanan, Rachna; Huitema, Leonie FA; VanBergen, Maaike; Apschner, Alexander; Peterson-Maduro, Josi; Logister, Ive; Valentin, Guillaume

    2018-01-01

    Segmentation of the axial skeleton in amniotes depends on the segmentation clock, which patterns the paraxial mesoderm and the sclerotome. While the segmentation clock clearly operates in teleosts, the role of the sclerotome in establishing the axial skeleton is unclear. We severely disrupt zebrafish paraxial segmentation, yet observe a largely normal segmentation process of the chordacentra. We demonstrate that axial entpd5+ notochord sheath cells are responsible for chordacentrum mineralization, and serve as a marker for axial segmentation. While autonomous within the notochord sheath, entpd5 expression and centrum formation show some plasticity and can respond to myotome pattern. These observations reveal for the first time the dynamics of notochord segmentation in a teleost, and are consistent with an autonomous patterning mechanism that is influenced, but not determined by adjacent paraxial mesoderm. This behavior is not consistent with a clock-type mechanism in the notochord. PMID:29624170

  19. Electronic Cigarettes Are as Toxic to Skin Flap Survival as Tobacco Cigarettes.

    PubMed

    Rau, Aline Sabrina; Reinikovaite, Viktorija; Schmidt, Eric P; Taraseviciene-Stewart, Laima; Deleyiannis, Frederic White-Brown

    2017-07-01

    Electronic cigarettes (e-cigarettes) have become increasingly popular. However, information about the health risks associated with e-cigarette use is sparse. Currently, no published studies examine the effects of chronic e-cigarette exposure on microcirculation or perfusion. Using a rat skin flap model, we examined the toxic microcirculatory effects e-cigarettes may have in comparison with tobacco cigarettes. Fifty-eight rats were randomized to either exposure to room air, tobacco cigarette smoke, medium-nicotine content (1.2%) e-cigarette vapor, or a high-nicotine content (2.4%) e-cigarette vapor. After 4 weeks of exposure, a random pattern, 3 × 9 cm skin flap was elevated on the dorsum of the rats. At 5 weeks, flap survival was evaluated quantitatively, and the rats were euthanized. Plasma was collected for nicotine and cotinine analysis, and flap tissues were harvested for histopathological analysis. Evaluation of the dorsal skin flaps demonstrated significantly increased necrosis in the vapor and tobacco groups. The average necrosis within the groups was as follows: control 19.23%, high-dose vapor 28.61%, medium-dose vapor 35.93%, and tobacco cigarette 30.15%. Although the e-cigarette and tobacco cigarette groups did not differ significantly, each individual group had significantly more necrosis than the control group (P<0.05). These results were corroborated with histopathological analysis of hypoxic tissue. Both the medium-content and high-nicotine content e-cigarette exposure groups had similar amounts of flap necrosis and hypoxia when compared with the tobacco cigarette exposure group. Nicotine-containing e-cigarette vapor is similarly toxic to skin flap survival as tobacco cigarettes.

  20. A study on the aerodynamic characteristics of airfoil in the flapping adjustment stage during forward flight

    NASA Astrophysics Data System (ADS)

    Luo, Pan; Zhang, Xingwei; Huang, Panpan; Xie, Lingwang

    2017-10-01

    The aim of this study is to investigate the aerodynamic characteristics of a flapping airfoil in the adjustment stage between two specific flight patterns during the forward flight. Four flapping movement models in adjustment stage are firstly established by using the multi-objective optimization algorithm. Then, a numerical experiment is carried out by using finite volume method to solve the two-dimensional time-dependent incompressible Navier-Stokes equations. The attack angles are selected from -5° to 7.5° with an increase of 2.5°. The results are systematically analyzed and special attention is paid to the corresponding changes of aerodynamic forces, vortex shedding mechanism in the wake structure and thrust efficiency. Present results show that output aerodynamic performance of flapping airfoil can be improved by the increasement of amplitude and frequency in the flapping adjustment stage, which further validates and complements previous studies. Moreover, it is also show that the manner using multi-objective optimization algorithm to generate a movement model in adjustment stage, to connect other two specific plunging motions, is a feasible and effective method. Current study is dedicated to providing some helpful references for the design and control of artificial flapping wing air vehicles.

  1. Naringin improves random skin flap survival in rats

    PubMed Central

    Cheng, Liang; Chen, Tingxiang; Tu, Qiming; Li, Hang; Feng, Zhenghua; Li, Zhijie; Lin, Dingsheng

    2017-01-01

    Background Random-pattern flap transfer is commonly used to treat soft-tissue defects. However, flap necrosis remains a serious problem. Naringin accelerates angiogenesis by activating the expression of vascular endothelial growth factor (VEGF). In the present study, we investigated whether naringin improves the survival of random skin flaps. Results Compared with controls, the naringin-treated groups exhibited significantly larger mean areas of flap survival, significantly increased SOD activity and VEGF expression, and significantly reduced MDA level. Hematoxylin and eosin (HE) staining revealed that naringin promoted angiogenesis and inhibited inflammation. Materials and Methods “McFarlane flap” models were established in 90 male Sprague-Dawley (SD) rats divided into three groups: a 40 mg/kg control group (0.5 % sodium carboxymethylcellulose), a 40 mg/kg naringin-treated group, and an 80 mg/kg naringin-treated group. The extent of necrosis was measured 7 days later, and tissue samples were subjected to histological analysis. Angiogenesis was evaluated via lead oxide–gelatin angiography, immunohistochemistry, and laser Doppler imaging. Inflammation was evaluated by measurement of serum TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) levels. Oxidative stress was assessed by measuring superoxide dismutase (SOD) activity and the malondialdehyde (MDA) level. Conclusion Naringin improved random skin flap survival. PMID:29212216

  2. A chimaeric-pattern flap design for implantable Doppler surrogate monitoring: a novel placement technique.

    PubMed

    Kim, Jeong Tae; Ho, Samuel Y M; Kim, Youn Hwan

    2014-02-01

    Postoperative flap monitoring is a vital aspect of free tissue transfer in order to detect early vascular compromise and to enable early flap salvage. The implantable Doppler monitoring system is one of many monitoring devices used to ensure accuracy and reduce unnecessary flap explorations. However, there are a number of concerns with its use, namely tension on the anastomosis, possible vessel constriction and false-negative detection. This study aimed to alleviate these concerns, by introducing a new method of placing the implantable Doppler probe on the adjacent vessel limb of a chimaeric flap. This is illustrated by a case series of chimaeric free tissue flaps that allow this surrogate placement of the Doppler probe. The flap is raised in a chimaeric fashion, with a main perforator pedicle to the skin or muscle paddle for the main reconstructive purpose and a side branch from the main pedicle going to a smaller adipofascial or muscle flap for monitoring. This branch vascular pedicle leading to the chimaeric tissue is kept sufficiently long to enable placement of the Doppler cuff and prevent turbulence. The probe of a Cook-Swartz implantable Doppler system is placed around the branch pedicle, approximately 5 mm from the branching point, and secured with a vessel clip. This is then secured away from the major vessels of the main free flap. Removal of the probe's crystal and wire is easily done with a single gentle traction on postoperative day 7. Five cases of chimaeric free flaps were performed with this manoeuvre: three thoracodorsal perforator chimaeric flaps for head-and-neck or extremity reconstruction, one latissimus dorsi neuromuscular chimaeric flap for facial reanimation and one digastric lymph node transfer for the treatment of lower limb lymphoedema. The Doppler system showed a low but sustained oscillating flow in all cases indicating vascular patency, with minimal flow interference from other large-calibre vessels. There was no discernible kinking on the anastomosis. There were no complications encountered during probe removal. This postoperative monitoring manoeuvre was done successfully with good results. The monitoring equipment is very sensitive to any flow disturbance due to positional changes in the head-and-neck region or the extremities and is able to detect flow changes in buried flaps postoperatively. Chimaeric flap composition is easier now than before because of perforator-oriented pedicle dissection, and surrogate Doppler monitoring is one more application of the chimaeric flap. This novel chimaeric fashion of implantable Doppler probe placement is a good surrogate measure of flow in the main pedicle. Copyright © 2013. Published by Elsevier Ltd.

  3. Anterior chamber gas bubble emergence pattern during femtosecond LASIK-flap creation.

    PubMed

    Robert, Marie-Claude; Khreim, Nour; Todani, Amit; Melki, Samir A

    2015-09-01

    To characterise the emergence pattern of cavitation bubbles into the anterior chamber (AC) following femtosecond laser-assisted in situ keratomileusis (LASIK)-flap creation Retrospective review of patients undergoing femtosecond LASIK surgery at Boston Laser, a private refractive surgery practice in Boston, Massachusetts, between December 2008 and February 2014. Patient charts were reviewed to identify all cases with gas bubble migration into the AC. Surgical videos were examined and the location of bubble entry was recorded separately for right and left eyes. Five thousand one hundred and fifty-eight patients underwent femtosecond LASIK surgery. Air bubble migration into the AC, presumably via the Schlemm's canal and trabecular meshwork, occurred in 1% of cases. Patients with AC bubbles had an average age of 33±8 years with a measured LASIK flap thickness of 96±21 μm. The occurrence of gas bubbles impaired iris registration in 64% of cases. Gas bubbles appeared preferentially in the nasal or inferior quadrants for right (92% of cases) and left (100% of cases) eyes. This bubble emergence pattern is significantly different from that expected with a random distribution (p<0.0001) and did not seem associated with decentration of the femtosecond laser docking system. The migration of gas bubbles into the AC is a rare occurrence during femtosecond laser flap creation. The preferential emergence of gas bubbles into the nasal and inferior quadrants of the AC may indicate a distinctive anatomy of the nasal Schlemm's canal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. Correction of severe postburn claw hand.

    PubMed

    Davami, Babak; Pourkhameneh, Golnar

    2011-12-01

    Burn scar contractures are perhaps the most frequent and most frustrating sequelae of thermal injuries to the hand. Unfortunately, stiffness occurs in the burned hand quickly. A week of neglect in the burned hand can lead to digital malpositioning and distortion that may be difficult to correct. The dorsal contracture is the most common of all the complications of the burned hand. It is the result of damage to the thin dorsal skin and scant subcutaneous tissue, which offers little protection to the deeper structures. Consequently, these injuries are deep resulting in a spectrum of deformities that has remained the bane of reconstructive surgery. Flap coverage will be required in the event of exposure of joints and tendons with absent paratenons. Multiple different flap types are available to treat complex severe postburn hand contractures. In our center, which is the largest regional burn center in northwest Iran, we have considerable experience in the treatment of thermal hand injuries. Between 2005 and 2010, we treated 53 consecutive patients with 65 severe postburn hand deformities. There were 35 men and 18 women with a mean age of 35±3 years. Flame injury was the inciting traumatic event in each patient. The severity of original injury and inadequate early treatment resulted in all of the fingers developing a severe extension contracture with scarred and adherent extensor tendons and subluxed metacarpophalangeal joints. In 36 cases, the injury was in the patients' dominant hand. We first incised the dorsal aspect of the contracted hands where there was maximum tension, then tenolysed the extensor tendons and released the volar capsules, collateral ligaments, and volar plate in all cases. In 30 cases, we also tenolysed the flexor tendons. We reduced the subluxed metacarpophalangeal joints and fixed them with Kirschner wires in 70 to 90 degrees flexion. Then, we planned and performed axial groin flaps to reconstruct the defects in all of them. In all of these patients, there was availability of intact skin in the territory of groin flap. However, in case of burn scars in this region, we had other options such as posterior interosseous flap in mind. Six patients experienced superficial necrosis at the distal margin of the flap, which was successfully treated with local wound care and dressing changes. There were no other complications. Physical therapy was initiated after Kirschner wire removal.

  5. Aerodynamics of the advanced launch system (ALS) propulsion and avionics (P/A) module

    NASA Technical Reports Server (NTRS)

    Ferguson, Stan; Savage, Dick

    1992-01-01

    This paper discusses the design and testing of candidate Advanced Launch System (ALS) Propulsion and Avionics (P/A) Module configurations. The P/A Module is a key element of future launch systems because it is essential to the recovery and reuse of high-value propulsion and avionics hardware. The ALS approach involves landing of first stage (booster) and/or second stage (core) P/A modules near the launch site to minimize logistics and refurbishment cost. The key issue addressed herein is the aerodynamic design of the P/A module, including the stability characteristics and the lift-to-drag (L/D) performance required to achieve the necessary landing guidance accuracy. The reference P/A module configuration was found to be statically stable for the desired flight regime, to provide adequate L/D for targeting, and to have effective modulation of the L/D performance using a body flap. The hypersonic aerodynamic trends for nose corner radius, boattail angle and body flap deflections were consistent with pretest predictions. However, the levels for the L/D and axial force for hypersonic Mach numbers were overpredicted by impact theories.

  6. Theory of the synchronous motion of an array of floating flap gates oscillating wave surge converter

    NASA Astrophysics Data System (ADS)

    Michele, Simone; Sammarco, Paolo; d'Errico, Michele

    2016-08-01

    We consider a finite array of floating flap gates oscillating wave surge converter (OWSC) in water of constant depth. The diffraction and radiation potentials are solved in terms of elliptical coordinates and Mathieu functions. Generated power and capture width ratio of a single gate excited by incoming waves are given in terms of the radiated wave amplitude in the far field. Similar to the case of axially symmetric absorbers, the maximum power extracted is shown to be directly proportional to the incident wave characteristics: energy flux, angle of incidence and wavelength. Accordingly, the capture width ratio is directly proportional to the wavelength, thus giving a design estimate of the maximum efficiency of the system. We then compare the array and the single gate in terms of energy production. For regular waves, we show that excitation of the out-of-phase natural modes of the array increases the power output, while in the case of random seas we show that the array and the single gate achieve the same efficiency.

  7. Experimental and numerical studies of beetle-inspired flapping wing in hovering flight.

    PubMed

    Van Truong, Tien; Le, Tuyen Quang; Park, Hoon Cheol; Byun, Doyoung

    2017-05-17

    In this paper, we measure unsteady forces and visualize 3D vortices around a beetle-like flapping wing model in hovering flight by experiment and numerical simulation. The measurement of unsteady forces and flow patterns around the wing were conducted using a dynamically scaled wing model in the mineral-oil tank. The wing kinematics were directly derived from the experiment of a real beetle. The 3D flow structures of the flapping wing were captured by using air bubble visualization while forces were measured by a sensor attached at the wing base. In comparison, the size and topology of spiral leading edge vortex, trailing edge vortex and tip vortex are well matched from experimental and numerical studies. In addition, the time history of forces calculated from numerical simulation is also similar to that from theforce measurement. A difference of average force is in order of 10 percent. The results indicate that the leading edge vortex due to rotational acceleration at the end of the stroke during flapping wing causes significant reduction of lift. The present study provides useful information on hover flight to develop a beetle-like flapping wing Micro Air Vehicle.

  8. Segmentation of the zebrafish axial skeleton relies on notochord sheath cells and not on the segmentation clock.

    PubMed

    Lleras Forero, Laura; Narayanan, Rachna; Huitema, Leonie Fa; VanBergen, Maaike; Apschner, Alexander; Peterson-Maduro, Josi; Logister, Ive; Valentin, Guillaume; Morelli, Luis G; Oates, Andrew C; Schulte-Merker, Stefan

    2018-04-06

    Segmentation of the axial skeleton in amniotes depends on the segmentation clock, which patterns the paraxial mesoderm and the sclerotome. While the segmentation clock clearly operates in teleosts, the role of the sclerotome in establishing the axial skeleton is unclear. We severely disrupt zebrafish paraxial segmentation, yet observe a largely normal segmentation process of the chordacentra. We demonstrate that axial entpd5+ notochord sheath cells are responsible for chordacentrum mineralization, and serve as a marker for axial segmentation. While autonomous within the notochord sheath, entpd5 expression and centrum formation show some plasticity and can respond to myotome pattern. These observations reveal for the first time the dynamics of notochord segmentation in a teleost, and are consistent with an autonomous patterning mechanism that is influenced, but not determined by adjacent paraxial mesoderm. This behavior is not consistent with a clock-type mechanism in the notochord. © 2018, Lleras Forero et al.

  9. Axial displacement of external and internal implant-abutment connection evaluated by linear mixed model analysis.

    PubMed

    Seol, Hyon-Woo; Heo, Seong-Joo; Koak, Jai-Young; Kim, Seong-Kyun; Kim, Shin-Koo

    2015-01-01

    To analyze the axial displacement of external and internal implant-abutment connection after cyclic loading. Three groups of external abutments (Ext group), an internal tapered one-piece-type abutment (Int-1 group), and an internal tapered two-piece-type abutment (Int-2 group) were prepared. Cyclic loading was applied to implant-abutment assemblies at 150 N with a frequency of 3 Hz. The amount of axial displacement, the Periotest values (PTVs), and the removal torque values(RTVs) were measured. Both a repeated measures analysis of variance and pattern analysis based on the linear mixed model were used for statistical analysis. Scanning electron microscopy (SEM) was used to evaluate the surface of the implant-abutment connection. The mean axial displacements after 1,000,000 cycles were 0.6 μm in the Ext group, 3.7 μm in the Int-1 group, and 9.0 μm in the Int-2 group. Pattern analysis revealed a breakpoint at 171 cycles. The Ext group showed no declining pattern, and the Int-1 group showed no declining pattern after the breakpoint (171 cycles). However, the Int-2 group experienced continuous axial displacement. After cyclic loading, the PTV decreased in the Int-2 group, and the RTV decreased in all groups. SEM imaging revealed surface wear in all groups. Axial displacement and surface wear occurred in all groups. The PTVs remained stable, but the RTVs decreased after cyclic loading. Based on linear mixed model analysis, the Ext and Int-1 groups' axial displacements plateaued after little cyclic loading. The Int-2 group's rate of axial displacement slowed after 100,000 cycles.

  10. The Lymphatic Response to Injury with Soft-Tissue Reconstruction in High-Energy Open Tibial Fractures of the Lower Extremity.

    PubMed

    van Zanten, Malou C; Mistry, Raakhi M; Suami, Hiroo; Campbell-Lloyd, Andrew; Finkemeyer, James P; Piller, Neil B; Caplash, Yugesh

    2017-02-01

    Severe compound tibial fractures are associated with extensive soft-tissue damage, resulting in disruption of lymphatic pathways that leave the patient at risk of developing chronic lymphedema. There are limited data on lymphatic response following lower limb trauma. Indocyanine green fluorescence lymphography is a novel, real-time imaging technique for superficial lymphatic mapping. The authors used this technique to image the superficial lymphatic vessels of the lower limbs in patients with severe compound tibial fracture. Baseline demographics and clinical and operative details were recorded in a prospective cohort of 17 patients who had undergone bone and soft-tissue reconstruction after severe compound tibial fracture between 2009 and 2014. Normal lymphatic images were obtained from the patients' noninjured limbs as a control. In this way, the authors investigated any changes to the normal anatomy of the lymphatic system in the affected limbs. Of the 17 patients, eight had free muscle flaps with split-thickness skin grafting, one had a free fasciocutaneous flap, one had a full-thickness skin graft, six had local fasciocutaneous flaps, and one had a pedicled gastrocnemius flap. None of the free flaps demonstrated any functional lymphatic vessels; the fasciocutaneous flaps and the skin graft demonstrated impaired lymphatic vessel function and dermal backflow pattern similar to that in lymphedema. Local flaps demonstrated lymphatic blockage at the scar edge. Severe compound fractures and the associated soft-tissue injury can result in significant lymphatic disruption and an increased risk for the development of chronic lymphedema.

  11. Magmatic controls on axial relief and faulting at mid-ocean ridges

    NASA Astrophysics Data System (ADS)

    Liu, Zhonglan; Buck, W. Roger

    2018-06-01

    Previous models do not simultaneously reproduce the observed range of axial relief and fault patterns at plate spreading centers. We suggest that this failure is due to the approximation that magmatic dikes open continuously rather than in discrete events. During short - lived events, dikes open not only in the strong axial lithosphere but also some distance into the underlying weaker asthenosphere. Axial valley relief affects the partitioning of magma between the lithosphere and asthenosphere during diking events. The deeper the valley, the more magma goes into lithospheric dikes in each event and so the greater the average opening rate of those dikes. The long-term rate of lithospheric dike opening controls faulting rate and axial depth. The feedback between axial valley depth D and lithospheric dike opening rate allows us to analytically relate steady-state values of D to lithospheric thickness HL and crustal thickness HC. A two-dimensional model numerical model with a fixed axial lithospheric structure illustrates the analytic model implications for axial faulting. The predictions of this new model are broadly consistent with global and segment-scale trends of axial depth and fault patterns with HL and HC.

  12. Axially staggered seed-blanket reactor-fuel-module construction. [LWBR

    DOEpatents

    Cowell, G.K.; DiGuiseppe, C.P.

    1982-10-28

    A heterogeneous nuclear reactor of the seed-blanket type is provided wherein the fissile (seed) and fertile (blanket) nuclear fuels are segregated axially within each fuel element such that fissile and fertile regions occur in an alternating pattern along the length of the fuel element. Further, different axial stacking patterns are used for the fuel elements of at least two module types such that when modules of different types are positioned adjacent to one another, the fertile regions of the modules are offset or staggered. Thus, when a module of one type is surrounded by modules of the second type the fertile regions thereof will be surrounded on all sides by fissile material. This provides enhanced neutron communication both radially and axially, thereby resulting in greater power oscillation stability than other axial arrangements.

  13. Automatic identification of bird targets with radar via patterns produced by wing flapping.

    PubMed

    Zaugg, Serge; Saporta, Gilbert; van Loon, Emiel; Schmaljohann, Heiko; Liechti, Felix

    2008-09-06

    Bird identification with radar is important for bird migration research, environmental impact assessments (e.g. wind farms), aircraft security and radar meteorology. In a study on bird migration, radar signals from birds, insects and ground clutter were recorded. Signals from birds show a typical pattern due to wing flapping. The data were labelled by experts into the four classes BIRD, INSECT, CLUTTER and UFO (unidentifiable signals). We present a classification algorithm aimed at automatic recognition of bird targets. Variables related to signal intensity and wing flapping pattern were extracted (via continuous wavelet transform). We used support vector classifiers to build predictive models. We estimated classification performance via cross validation on four datasets. When data from the same dataset were used for training and testing the classifier, the classification performance was extremely to moderately high. When data from one dataset were used for training and the three remaining datasets were used as test sets, the performance was lower but still extremely to moderately high. This shows that the method generalizes well across different locations or times. Our method provides a substantial gain of time when birds must be identified in large collections of radar signals and it represents the first substantial step in developing a real time bird identification radar system. We provide some guidelines and ideas for future research.

  14. The influence of impact direction and axial loading on the bone fracture pattern.

    PubMed

    Cohen, Haim; Kugel, Chen; May, Hila; Medlej, Bahaa; Stein, Dan; Slon, Viviane; Brosh, Tamar; Hershkovitz, Israel

    2017-08-01

    The effect of the direction of the impact and the presence of axial loading on fracture patterns have not yet been established in experimental 3-point bending studies. To reveal the association between the direction of the force and the fracture pattern, with and without axial loading. A Dynatup Model POE 2000 (Instron Co.) low energy pendulum impact machine was utilized to apply impact loading on fresh pig femoral bones (n=50). The bone clamp shaft was adjusted to position the bone for three-point bending with and without additional bone compression. Four different directions of the force were applied: anterior, posterior, lateral, and medial. The impacted aspect can be distinguished from the non-impacted aspects based on the fracture pattern alone (the most fractured one); the impact point can be identified on bare bones (the area from which all oblique lines radiate and/or the presence of a chip fragment). None of our experiments (with and without compression) yielded a "true" butterfly fracture, but instead, oblique radiating lines emerged from the point of impact (also known as "false" butterfly). Impacts on the lateral and anterior aspects of the bones produce more and longer fracture lines than impacts on the contralateral side; bones subjected to an impact with axial loading are significantly more comminuted and fragmented. Under axial loading, the number of fracture lines is independent of the impact direction. Our study presents an experimental model for fracture analysis and shows that the impact direction and the presence of axial loading during impact significantly affect the fracture pattern obtained. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Design and development of flapping wing micro air vehicle

    NASA Astrophysics Data System (ADS)

    Hynes, N. Rajesh Jesudoss; Solomon, A. Jeffey Markus; Kathiresh, E.; Brighton, D.; Velu, P. Shenbaga

    2018-05-01

    Birds and insects have different methods of producing lift and thrust for hovering and forward flight. Most birds, however, cannot hover. Wing tips of birds follow simple paths in flight, whereas insects have very complicated wing tip paths, for hovering and forward flight, which vary with each species. FMAV based on avian flight. Development of Flapping Wing Air Vehicle (FWAV) is an on-going quest to master the natural flyers by mechanical means. It is characterized by unsteady aerodynamics, whose knowledge is still developing. The present work aims at include being capable of manoeuvring around and over obstacles by adjusting pitch, yaw, and roll, able to glide for five seconds under its own power, skilful at alternating between flapping and gliding with minimal disruption of flight pattern and being durable enough to withstand impacts with minimal to no damage.

  16. Novel method for measuring a dense 3D strain map of robotic flapping wings

    NASA Astrophysics Data System (ADS)

    Li, Beiwen; Zhang, Song

    2018-04-01

    Measuring dense 3D strain maps of the inextensible membranous flapping wings of robots is of vital importance to the field of bio-inspired engineering. Conventional high-speed 3D videography methods typically reconstruct the wing geometries through measuring sparse points with fiducial markers, and thus cannot obtain the full-field mechanics of the wings in detail. In this research, we propose a novel system to measure a dense strain map of inextensible membranous flapping wings by developing a superfast 3D imaging system and a computational framework for strain analysis. Specifically, first we developed a 5000 Hz 3D imaging system based on the digital fringe projection technique using the defocused binary patterns to precisely measure the dynamic 3D geometries of rapidly flapping wings. Then, we developed a geometry-based algorithm to perform point tracking on the precisely measured 3D surface data. Finally, we developed a dense strain computational method using the Kirchhoff-Love shell theory. Experiments demonstrate that our method can effectively perform point tracking and measure a highly dense strain map of the wings without many fiducial markers.

  17. Baseline peripheral refractive error and changes in axial refraction during one year in a young adult population.

    PubMed

    Hartwig, Andreas; Charman, William Neil; Radhakrishnan, Hema

    2016-01-01

    To determine whether the initial characteristics of individual patterns of peripheral refraction relate to subsequent changes in refraction over a one-year period. 54 myopic and emmetropic subjects (mean age: 24.9±5.1 years; median 24 years) with normal vision were recruited and underwent conventional non-cycloplegic subjective refraction. Peripheral refraction was also measured at 5° intervals over the central 60° of horizontal visual field, together with axial length. After one year, measurements of subjective refraction and axial length were repeated on the 43 subjects who were still available for examination. In agreement with earlier studies, higher myopes tended to show greater relative peripheral hyperopia. There was, however, considerable inter-subject variation in the pattern of relative peripheral refractive error (RPRE) at any level of axial refraction. Across the group, mean one-year changes in axial refraction and axial length did not differ significantly from zero. There was no correlation between changes in these parameters for individual subjects and any characteristic of their RPRE. No evidence was found to support the hypothesis that the pattern of RPRE is predictive of subsequent refractive change in this age group. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  18. Animated axial surface mapping: The multimedia companion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hook, S.C.; Shaw, J.H.; Suppe, J.

    1995-09-01

    This newly expanded version of AAPG`s first DataShare Disk brings to life the concepts and applications of a new method of structural trend analysis. Through the dynamic use of color, sound, animation, and humor, this multimedia companion to the May 1994 article on Axial Surface Mapping introduces the reader (or viewer) to the concepts of rigid-block translation, fault-bend folding, and axial surface mapping. Animated models of growing fault-bend folds allow the viewer to see in four dimensions. The axial surface map shows the horizontal plane; the folding lines show depth planes; and the animations show the structure and its two-dimensionalmore » map changing with time and increasing slip. The animations create theoretical map patterns under varying, but controlled conditions that can be compared to axial surface maps from real data. The model patterns are then used to interpret seismic data and axial surface maps from a producing gas field in offshore California and from an exploration play in Pennsylvania.« less

  19. Axially staggered seed-blanket reactor fuel module construction

    DOEpatents

    Cowell, Gary K.; DiGuiseppe, Carl P.

    1985-01-01

    A heterogeneous nuclear reactor of the seed-blanket type is provided wher the fissile (seed) and fertile (blanket) nuclear fuels are segregated axially within each fuel element such that fissile and fertile regions occur in an alternating pattern along the length of the fuel element. Further, different axial stacking patterns are used for the fuel elements of at least two module types such that when modules of different types are positioned adjacent to one another, the fertile regions of the modules are offset or staggered. Thus, when a module of one type is surrounded by modules of the second type the fertile regions thereof will be surrounded on all sides by fissile material. This provides enhanced neutron communication both radially and axially, thereby resulting in greater power oscillation stability than other axial arrangements. The arrangements of the fissile and fertile regions in an alternating axial manner minimizes the radial power peaking factors and provides a more optional thermal-hydraulic design than is afforded by radial arrangements.

  20. Aerodynamic forces and flow structures of the leading edge vortex on a flapping wing considering ground effect.

    PubMed

    Van Truong, Tien; Byun, Doyoung; Kim, Min Jun; Yoon, Kwang Joon; Park, Hoon Cheol

    2013-09-01

    The aim of this work is to provide an insight into the aerodynamic performance of the beetle during takeoff, which has been estimated in previous investigations. We employed a scaled-up electromechanical model flapping wing to measure the aerodynamic forces and the three-dimensional flow structures on the flapping wing. The ground effect on the unsteady forces and flow structures were also characterized. The dynamically scaled wing model could replicate the general stroke pattern of the beetle's hind wing kinematics during takeoff flight. Two wing kinematic models have been studied to examine the influences of wing kinematics on unsteady aerodynamic forces. In the first model, the angle of attack is asymmetric and varies during the translational motion, which is the flapping motion of the beetle's hind wing. In the second model, the angle of attack is constant during the translational motion. The instantaneous aerodynamic forces were measured for four strokes during the beetle's takeoff by the force sensor attached at the wing base. Flow visualization provided a general picture of the evolution of the three-dimensional leading edge vortex (LEV) on the beetle hind wing model. The LEV is stable during each stroke, and increases radically from the root to the tip, forming a leading-edge spiral vortex. The force measurement results show that the vertical force generated by the hind wing is large enough to lift the beetle. For the beetle hind wing kinematics, the total vertical force production increases 18.4% and 8.6% for the first and second strokes, respectively, due to the ground effect. However, for the model with a constant angle of attack during translation, the vertical force is reduced during the first stroke. During the third and fourth strokes, the ground effect is negligible for both wing kinematic patterns. This finding suggests that the beetle's flapping mechanism induces a ground effect that can efficiently lift its body from the ground during takeoff.

  1. Fine lattice lines on the corneal surface after laser in situ keratomileusis (LASIK).

    PubMed

    Carpel, E F; Carlson, K H; Shannon, S

    2000-03-01

    To present an example of a pattern of lines resembling fine lattice on the corneal surface subsequent to laser in situ keratomileusis (LASIK). This subtle phenomenon may be relatively common and may affect visual outcome. Case report. A 41-year-old year old man with high myopia and best-corrected visual acuity of 20/20 +2 in each eye underwent laser in situ keratomileusis (LASIK). No operative or postoperative complications occurred. No striae were evident on slit-lamp examination with direct illumination and retroillumination at the time of surgery or in the postoperative period. Postoperative uncorrected visual acuity was 20/25 with a best-corrected spectacle correction of 20/25 in both eyes. Fine lines in a lattice pattern were seen only with fluorescein dye in the precorneal tear film as areas of "negative stain" within the LASIK flap. With tear film supplementation, the lines were less evident and visual acuity improved. One year postoperatively, his uncorrected visual acuity was 20/25 in both eyes. The best-corrected spectacle visual acuity was RE: 20/20 -2, LE: 20/25. The fine lines were still present within the flap. A soft contact lens improved visual acuity to 20/20 in both eyes. Although all four puncta were occluded, he had no epiphora. Fine lines in a lattice pattern that may represent folds in the epithelium or Bowman layer may be present within the flap after LASIK and may adversely affect visual acuity. They may be visible as areas of negative stain with fluorescein dye in the precorneal tear film in the absence of any striae visible in the flap. These superficial lines have been seen more in patients with high degrees of correction and in patients with dry eye. If visual acuity is affected, it may be improved with punctal occlusion, tear supplements, or a contact lens.

  2. Comparative analysis of the development of wing-flapping and flight in the fowl.

    PubMed

    Provine, R R; Strawbridge, C L; Harrison, B J

    1984-01-01

    The development of wing-flapping rate, lateral flight, wing area, and the ratio of wing area to body weight are described in the Japanese quail (Coturnix coturnix japonica) and three chickens (Gallus gallus) to determine common developmental phenomena and to assess the effects of domestication. The chickens were the White Leghorn (a commercial egg producer), the Cornish X Rock (a commercial meat producer), and the Red Jungle fowl (the probable ancestor of domestic chickens). All birds performed drop-evoked wing-flapping on the day of hatching, at least 1 week before lateral flight was possible. Flapping rate of chickens doubled between hatching (approximately 4-6 Hz) and 13 days (approximately 9-12 Hz), after which it leveled off. Japanese quail (JQ) maintained a high flapping rate (approximately 11-13 Hz) during the 21 days after hatching. The Jungle fowl (JF) and JQ flapped the fastest and the White Leghorn (WL) and Cornish X Rock (CR) chickens flapped the slowest. The JF, WL, and JQ developed lateral flight at 7-9 days. The CR first flew 1-2 weeks later but subsequently became flightless. The WL, JF, and JQ had similar ratios of wing area to body weight; the ratios increased to a peak at 11-15 days and later declined. The ratio of the very heavy, essentially flightless, CR was approximately one-half that of the flighted JQ, WL, and JF. The wing-flapping frequencies of the domestic WL and CR chickens approximated that of the JF, suggesting that domestication did not affect the motor pattern generator for flight. The artificial selection of the CR for high body weight drastically diminished its flight performance by producing an unfavorable ratio of wing area to body weight. The JF and the domestic WL both flew well and had similar ratios. Domestication affected flight performance but not the neural circuitry producing wing-flapping. The central nervous system is much more conservative in its response to selection than the peripheral effector structures that it drives.

  3. A dynamic spar numerical model for passive shape change

    NASA Astrophysics Data System (ADS)

    Calogero, J. P.; Frecker, M. I.; Hasnain, Z.; Hubbard, J. E., Jr.

    2016-10-01

    A three-dimensional constraint-driven dynamic rigid-link numerical model of a flapping wing structure with compliant joints (CJs) called the dynamic spar numerical model is introduced and implemented. CJs are modeled as spherical joints with distributed mass and spring-dampers with coupled nonlinear spring and damping coefficients, which models compliant mechanisms spatially distributed in the structure while greatly reducing computation time compared to a finite element model. The constraints are established, followed by the formulation of a state model used in conjunction with a forward time integrator, an experiment to verify a rigid-link assumption and determine a flapping angle function, and finally several example runs. Modeling the CJs as coupled bi-linear springs shows the wing is able to flex more during upstroke than downstroke. Coupling the spring stiffnesses allows an angular deformation about one axis to induce an angular deformation about another axis, where the magnitude is proportional to the coupling term. Modeling both the leading edge and diagonal spars shows that the diagonal spar changes the kinematics of the leading edge spar verses only considering the leading edge spar, causing much larger axial rotations in the leading edge spar. The kinematics are very sensitive to CJ location, where moving the CJ toward the wing root causes a stronger response, and adding multiple CJs on the leading edge spar with a CJ on the diagonal spar allows the wing to deform with larger magnitude in all directions. This model lays a framework for a tool which can be used to understand flapping wing flight.

  4. Numerical Studies of Three-dimensional Breakdown in Trailing Vortex Wakes

    NASA Technical Reports Server (NTRS)

    Evans, P. F.; Hackett, J. E.

    1976-01-01

    Finite element, three dimensional relaxation methods are used to calculate the development of vortex wakes behind aircraft for a considerable downstream distance. The inclusion of a self-induction term in the solution, dependent upon local curvature and vortex core radius, permits calculation of finite lifetimes for systems for which infinite life would be predicted two dimensionally. The associated computer program is described together with single-pair, twin-pair, and multiple-pair studies carried out using it. It is found, in single-pair studies, that there is a lower limit to the wavelengths at which the Crow-type of instability can occur. Below this limit, self-induction effects cause the plane of the disturbance waves to rotate counter to the vortex direction. Self induction in two dimensionally generated twin spiral waves causes an increase in axial length which becomes more marked with decreasing initial wavelength. The time taken for vortex convergence toward the center plane is correspondingly increased. The limited parametric twin-pair study performed suggests that time-to-converge increases with increasing flap span. Limited studies of Boeing 747 configurations show correct qualitative response to removal of the outer flap and to gear deployment, as compared with wind tunnel and flight test experience.

  5. Changes in shoulder muscle activity pattern on surface electromyography after breast cancer surgery.

    PubMed

    Yang, Eun Joo; Kwon, YoungOk

    2018-02-01

    Alterations in muscle activation and restricted shoulder mobility, which are common in breast cancer patients, have been found to affect upper limb function. The purpose of this study was to determine muscle activity patterns, and to compare the prevalence of abnormal patterns among the type of breast surgery. In total, 274 breast cancer patients were recruited after surgery. Type of breast surgery was divided into mastectomy without reconstruction (Mastectomy), reconstruction with tissue expander/implant (TEI), latissimus dorsi (LD) flap, or transverse rectus abdominis flap (TRAM). Activities of shoulder muscles were measured using surface electromyography. Experimental analysis was conducted using a Gaussian filter smoothing method with regression. Patients demonstrated different patterns of muscle activation, such as normal, lower muscle electrical activity, and tightness. After adjusting for BMI and breast surgery, the odds of lower muscle electrical activity and tightness in the TRAM are 40.2% and 38.4% less than in the Mastectomy only group. The prevalence of abnormal patterns was significantly greater in the ALND than SLNB in all except TRAM. Alterations in muscle activity patterns differed by breast surgery and reconstruction type. For breast cancer patients with ALND, TRAM may be the best choice for maintaining upper limb function. © 2017 Wiley Periodicals, Inc.

  6. Rotordynamic Behavior Of Sawtooth-Pattern Damping Seals

    NASA Technical Reports Server (NTRS)

    Nolan, Steven A.

    1992-01-01

    Report describes comparative experimental and theoretical study of rotordynamics of several different annular liquid pump seals. Introduces damping seals of new type in which inner surfaces of stators have saw-tooth-cross-section axial grooves interrupted at regular axial intervals by circumferential dams. Teeth of sawtooth patterns directed against rotations in attempt to reduce further asymptotic circumferential velocities of fluids.

  7. Flow field of flexible flapping wings

    NASA Astrophysics Data System (ADS)

    Sallstrom, Erik

    The agility and maneuverability of natural fliers would be desirable to incorporate into engineered micro air vehicles (MAVs). However, there is still much for engineers to learn about flapping flight in order to understand how such vehicles can be built for efficient flying. The goal of this study is to develop a methodology for capturing high quality flow field data around flexible flapping wings in a hover environment and to interpret it to gain a better understanding of how aerodynamic forces are generated. The flow field data was captured using particle image velocimetry (PIV) and required that measurements be taken around a repeatable flapping motion to obtain phase-averaged data that could be studied throughout the flapping cycle. Therefore, the study includes the development of flapping devices with a simple repeatable single degree of freedom flapping motion. The acquired flow field data has been examined qualitatively and quantitatively to investigate the mechanisms behind force production in hovering flight and to relate it to observations in previous research. Specifically, the flow fields have been investigated around a rigid wing and several carbon fiber reinforced flexible membrane wings. Throughout the whole study the wings were actuated with either a sinusoidal or a semi-linear flapping motion. The semi-linear flapping motion holds the commanded angular velocity nearly constant through half of each half-stroke while the sinusoidal motion is always either accelerating or decelerating. The flow fields were investigated by examining vorticity and vortex structures, using the Q criterion as the definition for the latter, in two and three dimensions. The measurements were combined with wing deflection measurements to demonstrate some of the key links in how the fluid-structure interactions generated aerodynamic forces. The flow fields were also used to calculate the forces generated by the flapping wings using momentum balance methods which yielded details of where along the wing the forces were generated. As expected, these results indicated that the spanwise location of where the forces were generated depended upon the wings membrane material and reinforcement pattern, but in general it was in the outer third of the wing. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)

  8. Kinematics of flap-bounding flight in the zebra finch over a wide range of speeds

    PubMed

    Tobalske; Peacock; Dial

    1999-07-01

    It has been proposed elsewhere that flap-bounding, an intermittent flight style consisting of flapping phases interspersed with flexed-wing bounds, should offer no savings in average mechanical power relative to continuous flapping unless a bird flies 1.2 times faster than its maximum range speed (Vmr). Why do some species use intermittent bounds at speeds slower than 1.2Vmr? The 'fixed-gear hypothesis' suggests that flap-bounding is used to vary mean power output in small birds that are otherwise constrained by muscle physiology and wing anatomy to use a fixed muscle shortening velocity and pattern of wing motion at all flight speeds; the 'body-lift hypothesis' suggests that some weight support during bounds could make flap-bounding flight aerodynamically advantageous in comparison with continuous flapping over most forward flight speeds. To test these predictions, we studied high-speed film recordings (300 Hz) of wing and body motion in zebra finches (Taenopygia guttata, mean mass 13.2 g, N=4) taken as the birds flew in a variable-speed wind tunnel (0-14 m s-1). The zebra finches used flap-bounding flight at all speeds, so their flight style was unique compared with that of birds that facultatively shift from continuous flapping or flap-gliding at slow speeds to flap-bounding at fast speeds. There was a significant effect of flight speed on all measured aspects of wing motion except percentage of the wingbeat spent in downstroke. Changes in angular velocity of the wing indicated that contractile velocity in the pectoralis muscle changed with flight speed, which is not consistent with the fixed-gear hypothesis. Although variation in stroke-plane angle relative to the body, pronation angle of the wing and wing span at mid-upstroke showed that the zebra finch changed within-wingbeat geometries according to speed, a vortex-ring gait with a feathered upstroke appeared to be the only gait used during flapping. In contrast, two small species that use continuous flapping during slow flight (0-4 m s-1) either change wingbeat gait according to flight speed or exhibit more variation in stroke-plane and pronation angles relative to the body. Differences in kinematics among species appear to be related to wing design (aspect ratio, skeletal proportions) rather than to pectoralis muscle fiber composition, indicating that the fixed-gear hypothesis should perhaps be modified to exclude muscle physiology and to emphasize constraints due to wing anatomy. Body lift was produced during bounds at speeds from 4 to 14 m s-1. Maximum body lift was 0.0206 N (15.9 % of body weight) at 10 m s-1; body lift:drag ratio declined with increasing air speed. The aerodynamic function of bounds differed with increasing speed from an emphasis on lift production (4-10 m s-1) to an emphasis on drag reduction with a slight loss in lift (12 and 14 m s-1). From a mathematical model of aerodynamic costs, it appeared that flap-bounding offered the zebra finch an aerodynamic advantage relative to continuous flapping at moderate and fast flight speeds (6-14 m s-1), with body lift augmenting any savings offered solely by flap-bounding at speeds faster than 7.1 m s-1. The percentage of time spent flapping during an intermittent flight cycle decreased with increasing speed, so the mechanical cost of transport was likely to be lowest at faster flight speeds (10-14 m s-1).

  9. Nonlinear flap-lag-axial equations of a rotating beam with arbitrary precone angle

    NASA Technical Reports Server (NTRS)

    Kvaternik, R. G.; White, W. F., Jr.; Kaza, K. R. V.

    1978-01-01

    In an attempt both to unify and extend the analytical basis of several aspects of the dynamic behavior of flexible rotating beams, the second-degree nonlinear equations of motion for the coupled flapwise bending, lagwise bending, and axial extension of an untwisted, torsionally rigid, nonuniform, rotating beam having an arbitrary angle of precone with the plane perpendicular to the axis of rotation are derived using Hamilton's principle. The derivation of the equations is based on the geometric nonlinear theory of elasticity and the resulting equations are consistent with the assumption that the strains are negligible compared to unity. No restrictions are imposed on the relative displacements or angular rotations of the cross sections of the beam other than those implied by the assumption of small strains. Illustrative numerical results, obtained by using an integrating matrix as the basis for the method of solution, are presented both for the purpose of validating the present method of solution and indicating the range of applicability of the equations of motion and the method of solution.

  10. Inviscid Flow Computations of the Shuttle Orbiter for Mach 10 and 15 and Angle of Attack 40 to 60 Degrees

    NASA Technical Reports Server (NTRS)

    Prabhu, Ramadas K.; Sutton, Kenneth (Technical Monitor)

    2001-01-01

    This report documents the results of a computational study done to compute the inviscid longitudinal aerodynamic characteristics of the Space Shuttle Orbiter for Mach numbers 10 and 15 at angles of attack of 40, 50, 55, and 60 degrees. These computations were done to provide limited aerodynamic data in support of the Orbiter contingency abort task. The Orbiter had all the control surfaces in the undeflected position. The unstructured grid software FELISA was used for these computations with the equilibrium air option. Normal and axial force coefficients and pitching moment coefficients were computed. The hinge moment coefficients of the body flap and the inboard and outboard elevons were also computed. These results were compared with Orbiter Air Data Book (OADB) data and those computed using GASP. The comparison with the GASP results showed very good agreement in Cm and Ca at all the points. The computed axial force coefficients were smaller than those computed by GASP. There were noticeable differences between the present results and those in the OADB at angles of attack greater than 50 degrees.

  11. Application of Posterior Thigh Three-Dimensional Profunda Artery Perforator Perforasomes in Refining Next-Generation Flap Designs: Transverse, Vertical, and S-Shaped Profunda Artery Perforator Flaps.

    PubMed

    Mohan, Anita T; Zhu, Lin; Sur, Yoo Joon; Morsy, Mohamed; Michalak, Gregory J; Lachman, Nirusha; Rammos, Charalambos K; Saint-Cyr, Michel

    2017-04-01

    This study aimed to delineate and compare the hot spots and three-dimensional vascular territories of dominant profunda artery perforators in the posterior thigh region, and modifications in flap design are discussed. Twenty-nine posterior thigh flaps were raised in fresh cadaveric specimens, and profunda artery perforators were documented. Dominant perforators were injected with iodinated contrast to assess perforasomes using computed tomographic angiography. Analysis with three-dimensional rendering and volume calculations of perfusion patterns was performed. In total, 316 perforators were mapped and 33 perforators were injected for analysis. The hot spot for dominant perforators was the proximal medial quadrant, 5 to 10 cm from the inferior gluteal crease, with two smaller hot spots in the upper lateral and distal posterior midline. Although 69 percent were musculocutaneous, distal perforators were predominantly septocutaneous in the posterior midline, 5 to 8 cm from the popliteal crease. Proximal perforators were classified into first (most proximal) and second perforators, and their median perforasome was 233 and 286.4 cm, respectively (p = 0.86). There were no significant differences between proximal and distal perforators in perforasome surface areas, percentage areas perfused, and perforasome volumes. Large linking vessel networks were attributed to a broader perforasome and greater overlap between adjacent or distal perforators. Dominant linking vessels and recurrent flow through the subdermal plexus contribute to the robust vascular supply of profunda artery perforator flaps. Posterior thigh region perforator hot spots and their perfusion characteristics can inform the potential limits, orientation, and modifications of flap or skin paddle designs.

  12. Mechanization and Control Concepts for Biologically Inspired Micro Aerial Vehicles

    NASA Technical Reports Server (NTRS)

    Raney, David L.; Slominski, Eric C.

    2003-01-01

    It is possible that MAV designs of the future will exploit flapping flight in order to perform missions that require extreme agility, such as rapid flight beneath a forest canopy or within the confines of a building. Many of nature's most agile flyers generate flapping motions through resonant excitation of an aeroelastically tailored structure: muscle tissue is used to excite a vibratory mode of their flexible wing structure that creates propulsion and lift. A number of MAV concepts have been proposed that would operate in a similar fashion. This paper describes an ongoing research activity in which mechanization and control concepts with application to resonant flapping MAVs are being explored. Structural approaches, mechanical design, sensing and wingbeat control concepts inspired by hummingbirds, bats and insects are examined. Experimental results from a testbed capable of generating vibratory wingbeat patterns that approximately match those exhibited by hummingbirds in hover, cruise, and reverse flight are presented.

  13. Flight mode affects allometry of migration range in birds.

    PubMed

    Watanabe, Yuuki Y

    2016-08-01

    Billions of birds migrate to exploit seasonally available resources. The ranges of migration vary greatly among species, but the underlying mechanisms are poorly understood. I hypothesise that flight mode (flapping or soaring) and body mass affect migration range through their influence on flight energetics. Here, I compiled the tracks of migratory birds (196 species, weighing 12-10 350 g) recorded by electronic tags in the last few decades. In flapping birds, migration ranges decreased with body mass, as predicted from rapidly increasing flight cost with increasing body mass. The species with higher aspect ratio and lower wing loading had larger migration ranges. In soaring birds, migration ranges were mass-independent and larger than those of flapping birds, reflecting their low flight costs irrespective of body mass. This study demonstrates that many animal-tracking studies are now available to explore the general patterns and the underlying mechanisms of animal migration. © 2016 John Wiley & Sons Ltd/CNRS.

  14. Effect of cineole, alpha-pinene, and camphor on survivability of skin flaps

    PubMed

    İnce, Bilsev; Dadacı, Mehmet; Kılınç, İbrahim; Oltulu, Pembe; Yarar, Serhat; Uyar, Mehmet

    2018-06-14

    Background/aim: The aim of this study was to determine the specific component of Rosmarinus officinalis (RO) responsible for increased flap survival and how RO displays its efficacy. Materials and methods: Rectangular random-pattern flaps were elevated from the back of each rat. Group I was the control group. In group II 0.1 mL of cineole, in group III 0.1 mL of alpha-pinene, in group IV 0.1 mL of camphor, in group V 0.1 mL each of alpha-pinene and cineole, in group VI 0.1 mL each of alpha-pinene and camphor, in group VII 0.1 mL each of cineole and camphor, and in group VIII, 0.1 mL each of alpha-pinene, cineole, and camphor was orally administered once a day before surgery. The luminal area of the largest blood vessel in the proximal flap was measured. Interleukin-1, tumor necrosis factor alpha, thiobarbituric acid reactive substances, and vascular endothelial growth factor values were measured. Results: The mean percentage of the viable surface area was significantly greater in groups VIII, III, and V. The mean percentage of vessel diameter was significantly greater in groups V, VIII, and VII. Conclusion: We suggest that alpha-pinene and cineole were the components of RO that were responsible for increased flap survival. The most effective of feature of RO was the antiinflammatory effects.

  15. Combined Use of GPS and Accelerometry Reveals Fine Scale Three-Dimensional Foraging Behaviour in the Short-Tailed Shearwater.

    PubMed

    Berlincourt, Maud; Angel, Lauren P; Arnould, John P Y

    2015-01-01

    Determining the foraging behaviour of free-ranging marine animals is fundamental for assessing their habitat use and how they may respond to changes in the environment. However, despite recent advances in bio-logging technology, collecting information on both at-sea movement patterns and activity budgets still remains difficult in small pelagic seabird species due to the constraints of instrument size. The short-tailed shearwater, the most abundant seabird species in Australia (ca 23 million individuals), is a highly pelagic procellariiform. Despite its ecological importance to the region, almost nothing is known about its at-sea behaviour, in particular, its foraging activity. Using a combination of GPS and tri-axial accelerometer data-loggers, the fine scale three-dimensional foraging behaviour of 10 breeding individuals from two colonies was investigated. Five at-sea behaviours were identified: (1) resting on water, (2) flapping flight, (3) gliding flight, (4) foraging (i.e., surface foraging and diving events), and (5) taking-off. There were substantial intra- and inter- individual variations in activity patterns, with individuals spending on average 45.8% (range: 17.1-70.0%) of time at sea resting on water and 18.2% (range: 2.3-49.6%) foraging. Individuals made 76.4 ± 65.3 dives (range: 8-237) per foraging trip (mean duration 9.0 ± 1.9 s), with dives also recorded during night-time. With the continued miniaturisation of recording devices, the use of combined data-loggers could provide us with further insights into the foraging behaviour of small procellariiforms, helping to better understand interactions with their prey.

  16. Comparison of two structured illumination techniques based on different 3D illumination patterns

    NASA Astrophysics Data System (ADS)

    Shabani, H.; Patwary, N.; Doblas, A.; Saavedra, G.; Preza, C.

    2017-02-01

    Manipulating the excitation pattern in optical microscopy has led to several super-resolution techniques. Among different patterns, the lateral sinusoidal excitation was used for the first demonstration of structured illumination microscopy (SIM), which provides the fastest SIM acquisition system (based on the number of raw images required) compared to the multi-spot illumination approach. Moreover, 3D patterns that include lateral and axial variations in the illumination have attracted more attention recently as they address resolution enhancement in three dimensions. A threewave (3W) interference technique based on coherent illumination has already been shown to provide super-resolution and optical sectioning in 3D-SIM. In this paper, we investigate a novel tunable technique that creates a 3D pattern from a set of multiple incoherently illuminated parallel slits that act as light sources for a Fresnel biprism. This setup is able to modulate the illumination pattern in the object space both axially and laterally with adjustable modulation frequencies. The 3D forward model for the new system is developed here to consider the effect of the axial modulation due to the 3D patterned illumination. The performance of 3D-SIM based on 3W interference and the tunable system are investigated in simulation and compared based on two different criteria. First, restored images obtained for both 3D-SIM systems using a generalized Wiener filter are compared to determine the effect of the illumination pattern on the reconstruction. Second, the effective frequency response of both systems is studied to determine the axial and lateral resolution enhancement that is obtained in each case.

  17. Unsteady behavior of a reattaching shear layer

    NASA Technical Reports Server (NTRS)

    Driver, D. M.; Seegmiller, H. L.; Marvin, J.

    1983-01-01

    A detailed investigation of the unsteadiness in a reattaching, turbulent shear layer is reported. Laser-Doppler velocimeter measurements were conditionally sampled on the basis of instantaneous flow direction near reattachment. Conditions of abnormally short reattachment and abnormally long reattachment were considered. Ensemble-averaging of measurements made during these conditions was used to obtain mean velocities and Rreynolds stresses. In the mean flow, conditional streamlines show a global change in flow pattern which correlates with wall-flow direction. This motion can loosely be described as a 'flapping' of the shear layer. Tuft probes show that the flow direction reversals occur quite randomly and are shortlived. Streses shown also vary with the change in flow pattern. Yet, the global'flapping' motion does not appear to contribute significantly to the stress in the flow. A second type of unsteady motion was identified. Spectral analysis of both wall static pressure and streamwise velocity shows that most of the energy in the flow resides in frequencies that are significantly lower than that of the turbulence. The dominant frequency is at a Strouhal number equal to 0.2, which is the characteristic frequency of roll-up and pairing of vortical structure seen in free shear layers. It is conjectured that the 'flapping' is a disorder of the roll-up and pairing process occurring in the shear layer.

  18. On the respiratory flow in the cuttlefish sepia officinalis.

    PubMed

    Bone, Q; Brown, E; Travers, G

    1994-09-01

    The respiratory flow of water over the gills of the cuttlefish Sepia officinalis at rest is produced by the alternate activity of the radial muscles of the mantle and the musculature of the collar flaps; mantle circular muscle fibres are not involved. Inspiration takes place as the radial fibres contract, thinning the mantle and expanding the mantle cavity. The rise in mantle cavity pressure (up to 0.15 kPa), expelling water via the siphon during expiration, is brought about by inward movement of the collar flaps and (probably) mainly by elastic recoil of the mantle connective tissue network 'wound up' by radial fibre contraction during inspiration. Sepia also shows a second respiratory pattern, in which mantle cavity pressures during expiration are greater (up to 0.25 kPa). Here, the mantle circular fibres are involved, as they are during the large pressure transients (up to 10 kPa) seen during escape jetting. Active contraction of the muscles of the collar flaps is seen in all three patterns of expulsion of water from the mantle cavity, electrical activity increasing with increasing mantle cavity pressures. Respiratory expiration in the resting squid Loligo vulgaris is probably driven as in Sepia, whereas in the resting octopus Eledone cirrhosa, the mantle circular musculature is active during expiration. The significance of these observations is discussed.

  19. Unsteady bio-fluid dynamics in flying and swimming

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Kolomenskiy, Dmitry; Nakata, Toshiyuki; Li, Gen

    2017-08-01

    Flying and swimming in nature present sophisticated and exciting ventures in biomimetics, which seeks sustainable solutions and solves practical problems by emulating nature's time-tested patterns, functions, and strategies. Bio-fluids in insect and bird flight, as well as in fish swimming are highly dynamic and unsteady; however, they have been studied mostly with a focus on the phenomena associated with a body or wings moving in a steady flow. Characterized by unsteady wing flapping and body undulation, fluid-structure interactions, flexible wings and bodies, turbulent environments, and complex maneuver, bio-fluid dynamics normally have challenges associated with low Reynolds number regime and high unsteadiness in modeling and analysis of flow physics. In this article, we review and highlight recent advances in unsteady bio-fluid dynamics in terms of leading-edge vortices, passive mechanisms in flexible wings and hinges, flapping flight in unsteady environments, and micro-structured aerodynamics in flapping flight, as well as undulatory swimming, flapping-fin hydrodynamics, body-fin interaction, C-start and maneuvering, swimming in turbulence, collective swimming, and micro-structured hydrodynamics in swimming. We further give a perspective outlook on future challenges and tasks of several key issues of the field.

  20. Analysis of the microcirculation after soft tissue reconstruction of the outer ear with burns in patients with severe burn injuries.

    PubMed

    Medved, Fabian; Medesan, Raluca; Rothenberger, Jens Martin; Schaller, Hans-Eberhard; Schoeller, Thomas; Manoli, Theodora; Weitgasser, Lennart; Naumann, Aline; Weitgasser, Laurenz

    2016-07-01

    Reconstruction of soft tissue defects of the ear with burns remains one of the most difficult tasks for the reconstructive surgeon. Although numerous reconstructive options are available, the results are often unpredictable and worse than expected. Besides full and split skin grafting, local random pattern flaps and pedicled flaps are frequently utilized to cover soft tissue defects of the outer auricle. Because of the difficulty and unpredictable nature of outer ear reconstruction after burn injury, a case-control study was conducted to determine the best reconstructive approach. The microcirculatory properties of different types of soft tissue reconstruction of the outer ear with burns in six severely burned Caucasian patients (three men and three women; mean age, 46 years (range, 22-70)) were compared to those in the healthy tissue of the outer ear using the O2C device (Oxygen to See; LEA Medizintechnik, Gießen, Germany). The results of this study revealed that the investigated microcirculation parameters such as the median values of blood flow (control group: 126 AU), relative amount of hemoglobin (control group: 59.5 AU), and tissue oxygen saturation (control group: 73%) are most similar to those of normal ear tissue when pedicled flaps based on the superficial temporal artery were used. These findings suggest that this type of reconstruction is superior for soft tissue reconstruction of the outer ear with burns in contrast to random pattern flaps and full skin grafts regarding the microcirculatory aspects. These findings may improve the knowledge on soft tissue viability and facilitate the exceptional and delicate process of planning the reconstruction of the auricle with burns. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. One stage reconstruction of the floor of the mouth with a subcutaneous pedicled nasolabial flap.

    PubMed

    El-Marakby, Hamdy H; Fouad, Fouad A; Ali, Ahmed H

    2012-06-01

    Nasolabial flaps have been recognised as versatile flaps for a variety of defects in the face, nose, lip and the oral cavity. Random pattern inferiorly based nasolabial flaps (NLF) have been utilised for covering small defects on the anterior floor of the mouth, but usually require a second stage procedure to divide the flap base. A subcutaneous pedicled inferiorly based nasolabial flap can provide a one stage repair of moderate sized defects of the floor of the mouth after de epithelialisation of the base of the flap. To evaluate the feasibility of a single stage reconstruction of intermediate sized defects in the oral cavity with an inferiorly based pedicled NLF. The study includes the indications of use of the flap, flap design, technique, and the complications rate. The incidence of secondary procedures and the final functional and the aesthetic results will also be evaluated. A group of 20 patients presented with (T1-2) squamous cell carcinoma of the oral cavity have been treated at the Department of Surgery, National Cancer Institute, Cairo; in the period between January 2008 and September 2010. The pathology was confirmed with an incision biopsy and all metastatic work were carried out confirming that all patients were free from distant metastasis at presentation. Preoperative assessment also included assessment of the stage of the disease, the flap design and patient fitness for general anaesthesia. All patients underwent surgical excision combined with reconstruction of the defect with a subcutaneous inferiorly based pedicled NLF. The proximal part of the flap was routinely de epithelialised before it has been tunnelled through the cheek so a one stage procedure could only be required. The mean age of the patients was 62.3±6years, range (52-69years). All patients were diagnosed with squamous cell carcinoma. The anterior floor of the mouth constituted 40% of the defects, the lateral floor of the mouth 20% and the inner surface of the cheek 40%. There was no reported major complication; and only one patient suffered a reactionary haemorrhage that required re-exploration to secure the bleeder. A single procedure was adequate in most patients (80%), only 20% of patients required revision of the scar at the donor site or release of the tongue. The overall aesthetic results were either very satisfactory or satisfactory in the majority of patients (90%). Two patients were not satisfied with the final aesthetic results, one suffered from ectropion and the other had a donor site wound healing problem. The functional results (deglutition, speech) were satisfactory in most patients (70%), all were edentulous. An inferiorly based pedicled NLF is a reliable flap for the reconstruction of small and medium sized defects in the oral cavity. The flap can be best utilised for old edentulous and high risk patients where it can be used as a single stage procedure which is particularly useful in those types of patients. The flap can be safely combined with neck dissection even when the facial artery was ligated. Copyright © 2012 National Cancer Institute, Cairo University. Published by Elsevier B.V. All rights reserved.

  2. SU-E-T-09: A Clinical Implementation and Optimized Dosimetry Study of Freiberg Flap Skin Surface Treatment in High Dose Rate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Syh, J; Syh, J; Patel, B

    Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists ofmore » multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.« less

  3. MRA of the skin: mapping for advanced breast reconstructive surgery.

    PubMed

    Thimmappa, N D; Vasile, J V; Ahn, C Y; Levine, J L; Prince, M R

    2018-02-27

    Autologous breast reconstruction using muscle-sparing free flaps are becoming increasingly popular, although microvascular free flap reconstruction has been utilised for autologous breast reconstructions for >20 years. This innovative microsurgical technique involves meticulous dissection of artery-vein bundle (perforators) responsible for perfusion of the subcutaneous fat and skin of the flap; however, due to unpredictable anatomical variations, preoperative imaging of the donor site to select appropriate perforators has become routine. Preoperative imaging also reduces operating time and enhances the surgeon's confidence in choosing the appropriate donor site for harvesting flaps. Although computed tomography angiography has been widely used for preoperative imaging, concerns over excessive exposure to ionising radiation and poor iodinated contrast agent enhancement of the intramuscular perforator course has made magnetic resonance angiography, the first choice imaging modality in our centre. Magnetic resonance angiography with specific post-processing of the images has established itself as a reliable method for mapping tiny perforator vessels. Multiple donor sites can be imaged in a single setting without concern for ionising radiation exposure. This provides anatomical information of more reconstruction donor site options, so that a surgeon can design a flap of tissue centralised around the best perforator, as well as a back-up perforator, and even a back-up flap option located on a different region of the body. This information is especially helpful in patients with a history of scar tissue from previous surgeries, where the primary choice perforator is found to be damaged or unsuitable intraoperatively. In addition, chest magnetic resonance angiography evaluates recipient site blood vessel suitability including vessel diameters, course, and branching patterns. In this article we provide a broad overview of various skin flaps, clinical indications, advantages and disadvantages of each of these flaps, basic imaging technique, along with advanced sequences for visualising tiny arteries in the groin and in the chest. Post-processing techniques, structure of the report and how automation of the reporting system improves workflow is described. We also describe applications of magnetic resonance angiography in postoperative imaging. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Referral Patterns, Diagnosis, and Disease Management of Patients With Axial Spondyloarthritis

    PubMed Central

    van der Heijde, Désirée; Sieper, Joachim; Elewaut, Dirk; Deodhar, Atul; Pangan, Aileen L.; Dorr, Alexander P.

    2014-01-01

    Background Recognition, diagnosis, and management of axial spondyloarthritis (axial SpA) continue to advance. Objectives The objectives of this study were to compare referrals, diagnosis, and management of axial SpA in Western Europe (WE), North America (US and Canada), and the rest of world (RoW) in academic and community rheumatology practices and to identify areas for further education. Methods Rheumatologists responded online to the MAXIMA (Management of Axial SpA International and Multicentric Approaches) survey. Questions pertained to referral, diagnosis, and management of axial SpA. Results Rheumatologists (N = 809) from 56 countries completed the survey about patients with chronic back pain (≥3 months) starting before age 45 years. Responses from academic and community practice rheumatologists were generally similar. Most referrals were from primary care providers. Symptom duration of 3 years or more at referral was reported more frequently by WE and RoW than US respondents. More WE and RoW than US rheumatologists referred to the Assessment of SpondyloArthritis International Society criteria for axial SpA in clinical practice. Rheumatologists reported prescribing disease-modifying antirheumatic drugs for the management of axial SpA. Sulfasalazine was frequently prescribed across regions; methotrexate was more commonly prescribed by US rheumatologists compared with other regions. Conclusions Referral patterns, diagnosis, and disease management for axial SpA were similar among WE, North America, and RoW rheumatologists and in academic/community practices, although more WE and RoW rheumatologists referred to Assessment of SpondyloArthritis International Society criteria in clinical practice. Disease-modifying antirheumatic drugs were commonly prescribed for axial SpA patients, although it was unclear whether these were prescribed for axial or peripheral symptoms. PMID:25417676

  5. Referral patterns, diagnosis, and disease management of patients with axial spondyloarthritis: results of an international survey.

    PubMed

    van der Heijde, Désirée; Sieper, Joachim; Elewaut, Dirk; Deodhar, Atul; Pangan, Aileen L; Dorr, Alexander P

    2014-12-01

    Recognition, diagnosis, and management of axial spondyloarthritis (axial SpA) continue to advance. The objectives of this study were to compare referrals, diagnosis, and management of axial SpA in Western Europe (WE), North America (US and Canada), and the rest of world (RoW) in academic and community rheumatology practices and to identify areas for further education. Rheumatologists responded online to the MAXIMA (Management of Axial SpA International and Multicentric Approaches) survey. Questions pertained to referral, diagnosis, and management of axial SpA. Rheumatologists (N = 809) from 56 countries completed the survey about patients with chronic back pain (≥3 months) starting before age 45 years. Responses from academic and community practice rheumatologists were generally similar. Most referrals were from primary care providers. Symptom duration of 3 years or more at referral was reported more frequently by WE and RoW than US respondents. More WE and RoW than US rheumatologists referred to the Assessment of SpondyloArthritis International Society criteria for axial SpA in clinical practice. Rheumatologists reported prescribing disease-modifying antirheumatic drugs for the management of axial SpA. Sulfasalazine was frequently prescribed across regions; methotrexate was more commonly prescribed by US rheumatologists compared with other regions. Referral patterns, diagnosis, and disease management for axial SpA were similar among WE, North America, and RoW rheumatologists and in academic/community practices, although more WE and RoW rheumatologists referred to Assessment of SpondyloArthritis International Society criteria in clinical practice. Disease-modifying antirheumatic drugs were commonly prescribed for axial SpA patients, although it was unclear whether these were prescribed for axial or peripheral symptoms.

  6. Analysis of methods to assess frontal sinus extent in osteoplastic flap surgery: transillumination versus 6-ft Caldwell versus image guidance.

    PubMed

    Melroy, Christopher T; Dubin, Marc G; Hardy, Stuart M; Senior, Brent A

    2006-01-01

    The aim of this study was to compare three common methods (transillumination, plain radiographs, and computerized tomography [CT] image guidance) for estimating the position and extent of pneumatization of the frontal sinus in osteoplastic flap surgery. Axial CT scans and 6-ft Caldwell radiographs were performed on 10 cadaver heads. For each head, soft tissue overlying the frontal bone was raised and the anticipated position and extent of the frontal sinus at four points was marked using three common methods. The silhouette of the frontal sinus from the Caldwell plain radiograph was excised and placed in position. Four points at the periphery also were made using information obtained from a passive optically guided image-guided surgery device, and transillumination via a frontal trephination also was used to estimate sinus extent. The true sinus size was measured at each point and compared with experimental values. The use of CT image guidance generated the least difference between measured and actual values (mean = 1.91 mm; SEM = 0.29); this method was found statistically superior to Caldwell (p = 0.040) and transillumination (p = 0.007). Image guidance did not overestimate the size of the sinus (0/36) and was quicker than the Caldwell approach (8.5 versus 11.5 minutes). There was no learning curve appreciated with image guidance. Accurate and precise estimation of the position and extent of the frontal sinus is crucial when performing osteoplastic flap surgery. Use of CT image guidance was statistically superior to Caldwell and transillumination methods and proved to be safe, reproducible, economic, and easy to learn.

  7. Numerical analyses of evolution of unsteady flow structures in the wake of flapping starling wing model

    NASA Astrophysics Data System (ADS)

    Krishnan, Krishnamoorthy; Naqavi, Iftekhar Z.; Gurka, Roi

    2017-11-01

    Understanding the physics of flapping wings at moderate Reynolds number flows takes on greater importance in the context of avian aerodynamics as well as in the design of miniature-aerial-vehicles. Analyzing the characteristics of wake vortices generated downstream of flapping wings can help to explain the unsteady contribution to the aerodynamics loads. In this study, numerical simulations of flow over a bio-inspired pseudo-2D flapping wing model was conducted to characterize the evolution of unsteady flow structures in the downstream wake of flapping wing. The wing model was based on a European starling's wing and wingbeat kinematics were incorporated to simulate a free-forward flight. The starling's wingbeat kinematics were extracted from experiments conducted in a wind tunnel where freely flying starling was measured using high-speed PIV as well as high-speed imaging yielding a series of kinematic images sampled at 500 Hz. The average chord of the wing section was 6 cm and simulations were carried out at a Reynolds number of 54,000, reduced frequency of 0.17, and Strouhal number of 0.16. Large eddy simulation was performed using a second order, finite difference code ParLES. Characteristics of wake vortex structures during the different phases of the wing strokes were examined. The role of wingbeat kinematics in the configuration of downstream vortex patterns is discussed. Evaluated wake topology and lift-drag characteristics are compared with the starling's wind tunnel results.

  8. Hydrodynamic pumping by serial gill arrays in the mayfly nymph Centroptilum triangulifer.

    PubMed

    Sensenig, Andrew T; Kiger, Ken T; Shultz, Jeffrey W

    2010-10-01

    Aquatic nymphs of the mayfly Centroptilum triangulifer produce ventilatory flow using a serial array of seven abdominal gill pairs that operates across a Reynolds numbers (Re) range from 2 to 22 during ontogeny. Net flow in small animals is directed ventrally and essentially parallel to the stroke plane (i.e. rowing), but net flow in large animals is directed dorsally and essentially transverse to the stroke plane (i.e. flapping). Detailed flow measurements based on Particle Image Velocimetry (PIV) ensemble-correlation analysis revealed that the phasing of the gills produces a time-dependent array of vortices associated with a net ventilatory current, a fluid kinematic pattern, here termed a 'phased vortex pump'. Absolute size of vortices does not change with increasing animal size or Re, and thus the vortex radius (R(v)) decreases relative to inter-gill distance (L(is)) during mayfly growth. Given that effective flapping in appendage-array animals requires organized flow between adjacent appendages, we hypothesize that rowing should be favored when L(is)/R(v)<1 and flapping should be favored when L(is)/R(v)>1. Significantly, the rowing-to-flapping transition in Centroptilum occurs at Re∼5, when the mean dynamic inter-gill distance equals the vortex radius. This result suggests that the Re-based rowing-flapping demarcation observed in appendage-array aquatic organisms may be determined by the relative size of the propulsive mechanism and its self-generated vortices.

  9. In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: preliminary results.

    PubMed

    Cutti, Andrea Giovanni; Cappello, Angelo; Davalli, Angelo

    2006-01-01

    Soft tissue artefact is the dominant error source for upper extremity motion analyses that use skin-mounted markers, especially in humeral axial rotation. A new in vivo technique is presented that is based on the definition of a humerus bone-embedded frame almost "artefact free" but influenced by the elbow orientation in the measurement of the humeral axial rotation, and on an algorithm designed to solve this kinematic coupling. The technique was validated in vivo in a study of six healthy subjects who performed five arm-movement tasks. For each task the similarity between a gold standard pattern and the axial rotation pattern before and after the application of the compensation algorithm was evaluated in terms of explained variance, gain, phase and offset. In addition the root mean square error between the patterns was used as a global similarity estimator. After the application, for four out of five tasks, patterns were highly correlated, in phase, with almost equal gain and limited offset; the root mean square error decreased from the original 9 degrees to 3 degrees . The proposed technique appears to help compensate for the soft tissue artefact affecting axial rotation. A further development is also proposed to make the technique effective also for the pure prono-supination task.

  10. SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buzurovic, I; Devlin, P; Hansen, J

    2014-06-01

    Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curvedmore » surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high level of positioning accuracy. Implementation of this technique has potential to decrease the planning time and may improve overall quality in superficial brachytherapy.« less

  11. [Klippel-Feil syndrome with tracheoesophageal fistula, bifid thumb and cerebral angiolipoma.

    PubMed

    Urdaneta Carruyo, Eliéxer; Rojas Zerpa, Gustavo; Urdaneta Contreras, Adriana; Maldonado Alviarez, Malvy; Brito Rodríguez, Miguel

    2016-12-01

    The Klippel-Feil syndrome is a congenital malformation of the skull flap involving complex cervical vertebrae and organs, characterized by a classic triad: short neck, limitation of movement of the head due to cervical spine fusion and low hairline in occipital region. It results from an error in the axial skeleton segmentation of the embryo; its incidence is estimated at 1/40,000-42,000 births and predominates in females. The aim of this paper is to describe the clinical picture of a patient with Klippel-Feil syndrome and multiple malformations, including tracheoesophageal fistula, bifid thumb and intracranial lipomas/angiolipomas,that have not been previously described in the syndrome, so it is considered an exceptional finding. Sociedad Argentina de Pediatría.

  12. Writing Forces Associated With Four Pencil Grasp Patterns in Grade 4 Children

    PubMed Central

    Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl

    2013-01-01

    OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. PMID:23433277

  13. Axially Tapered And Bilayer Microchannels For Evaporative Cooling Devices

    DOEpatents

    Nilson, Robert; Griffiths, Stewart

    2005-10-04

    The invention consists of an evaporative cooling device comprising one or more microchannels whose cross section is axially reduced to control the maximum capillary pressure differential between liquid and vapor phases. In one embodiment, the evaporation channels have a rectangular cross section that is reduced in width along a flow path. In another embodiment, channels of fixed width are patterned with an array of microfabricated post-like features such that the feature size and spacing are gradually reduced along the flow path. Other embodiments incorporate bilayer channels consisting of an upper cover plate having a pattern of slots or holes of axially decreasing size and a lower fluid flow layer having channel widths substantially greater than the characteristic microscale dimensions of the patterned cover plate. The small dimensions of the cover plate holes afford large capillary pressure differentials while the larger dimensions of the lower region reduce viscous flow resistance.

  14. The effect of wing flexibility on sound generation of flapping wings.

    PubMed

    Geng, Biao; Xue, Qian; Zheng, Xudong; Liu, Geng; Ren, Yan; Dong, Haibo

    2017-12-13

    In this study, the unsteady flow and acoustic characteristics of a three-dimensional (3D) flapping wing model of a Tibicen linnei cicada in forward-flight are numerically investigated. A single cicada wing is modelled as a membrane with a prescribed motion reconstructed from high-speed videos of a live insect. The numerical solution takes a hydrodynamic/acoustic splitting approach: the flow field is solved with an incompressible Navier-Stokes flow solver based on an immersed boundary method, and the acoustic field is solved with linearized perturbed compressible equations. The 3D simulation allows for the examination of both the directivity and frequency compositions of the flapping wing sound in a full space. Along with the flexible wing model, a rigid wing model that is extracted from real motion is also simulated to investigate the effects of wing flexibility. The simulation results show that the flapping sound is directional; the dominant frequency varies around the wing. The first and second frequency harmonics show different radiation patterns in the rigid and flexible wing cases, which are demonstrated to be highly associated with wing kinematics and loadings. Furthermore, the rotation and deformation in the flexible wing is found to help lower the sound strength in all directions.

  15. Flight testing of live Monarch butterflies to determine the aerodynamic benefit of butterfly scales

    NASA Astrophysics Data System (ADS)

    Lang, Amy; Cranford, Jacob; Conway, Jasmine; Slegers, Nathan; Dechello, Nicole; Wilroy, Jacob

    2014-11-01

    Evolutionary adaptations in the morphological structure of butterfly scales (0.1 mm in size) to develop a unique micro-patterning resulting in a surface drag alteration, stem from a probable aerodynamic benefit of minimizing the energy requirement to fly a very lightweight body with comparably large surface area in a low Re flow regime. Live Monarch butterflies were tested at UAHuntsville's Autonomous Tracking and Optical Measurement (ATOM) Laboratory, which uses 22 Vicon T40 cameras that allow for millimeter level tracking of reflective markers at 515 fps over a 4 m × 6 m × 7 m volume. Data recorded included the flight path as well as the wing flapping angle and wing-beat frequency. Insects were first tested with their scales intact, and then again with the scales carefully removed. Differences in flapping frequency and/or energy obtained during flight due to the removal of the scales will be discussed. Initial data analysis indicates that scale removal in some specimens leads to increased flapping frequencies for similar energetic flight or reduced flight speed for similar flapping frequencies. Both results point to the scales providing an aerodynamic benefit, which is hypothesized to be linked to leading-edge vortex formation and induced drag. Funding from the National Science Foundation (CBET and REU) is gratefully acknowledged.

  16. High-frequency performance for a spiral-shaped piezoelectric bimorph

    NASA Astrophysics Data System (ADS)

    Huang, Fang Sheng; Feng, Zhi Hua; Ma, Yu Ting; Pan, Qiao Sheng; Zhang, Lian Sheng; Liu, Yong Bin; He, Liang Guo

    2018-04-01

    Piezoelectric cantilever is suitable as an actuator for micro-flapping-wing aircraft. Higher resonant frequency brings about stronger flight energy, and the flight amplitude can be compensated by displacement-amplification mechanism, such as lever. To obtain a higher resonant frequency, straight piezoelectric bimorph was rolled into spiral-shaped piezoelectric bimorph with identical effective length in this study, which is verified in COMSOL simulations. Simulation results show that compared with the straight piezoelectric bimorph, the spiral-shaped piezoelectric bimorph with two turns has higher inherent frequencies (from 204.79 Hz to 504.84 Hz in terms of axial oscillation mode, and from 319.77 Hz to 704.48 Hz in terms of tangential torsional mode). The spiral-shaped piezoelectric bimorph is fabricated by a precise laser cutting process and consists of two turns with effective length of 60 mm, width of 2.5 mm, and thickness of 1.6 mm, respectively. With the excitation voltage of 100 Vpp applying an electric field across the thickness of the bimorph, the tip displacement of the actuator in the axial oscillation and tangential torsional modes are 85 μm and 15 μm, respectively.

  17. Neuroinspired control strategies with applications to flapping flight

    NASA Astrophysics Data System (ADS)

    Dorothy, Michael Ray

    This dissertation is centered on a theoretical, simulation, and experimental study of control strategies which are inspired by biological systems. Biological systems, along with sufficiently complicated engineered systems, often have many interacting degrees of freedom and need to excite large-displacement oscillations in order to locomote. Combining these factors can make high-level control design difficult. This thesis revolves around three different levels of abstraction, providing tools for analysis and design. First, we consider central pattern generators (CPGs) to control flapping-flight dynamics. The key idea here is dimensional reduction - we want to convert complicated interactions of many degrees of freedom into a handful of parameters which have intuitive connections to the overall system behavior, leaving the control designer unconcerned with the details of particular motions. A rigorous mathematical and control theoretic framework to design complex three-dimensional wing motions is presented based on phase synchronization of nonlinear oscillators. In particular, we show that flapping-flying dynamics without a tail or traditional aerodynamic control surfaces can be effectively controlled by a reduced set of central pattern generator parameters that generate phase-synchronized or symmetry-breaking oscillatory motions of two main wings. Furthermore, by using a Hopf bifurcation, we show that tailless aircraft (inspired by bats) alternating between flapping and gliding can be effectively stabilized by smooth wing motions driven by the central pattern generator network. Results of numerical simulation with a full six-degree-of-freedom flight dynamic model validate the effectiveness of the proposed neurobiologically inspired control approach. Further, we present experimental micro aerial vehicle (MAV) research with low-frequency flapping and articulated wing gliding. The importance of phase difference control via an abstract mathematical model of central pattern generators is confirmed with a robotic bat on a 3-DOF pendulum platform. An aerodynamic model for the robotic bat based on the complex wing kinematics is presented. Closed loop experiments show that control dimension reduction is achievable - unstable longitudinal modes are stabilized and controlled using only two control parameters. A transition of flight modes, from flapping to gliding and vice-versa, is demonstrated within the CPG control scheme. The second major thrust is inspired by this idea that mode switching is useful. Many bats and birds adopt a mixed strategy of flapping and gliding to provide agility when necessary and to increase overall efficiency. This work explores dwell time constraints on switched systems with multiple, possibly disparate invariant limit sets. We show that, under suitable conditions, trajectories globally converge to a superset of the limit sets and then remain in a second, larger superset. We show the effectiveness of the dwell-time conditions by using examples of nonlinear switching limit cycles from our work on flapping flight. This level of abstraction has been found to be useful in many ways, but it also produces its own challenges. For example, we discuss death of oscillation which can occur for many limit-cycle controllers and the difficulty in incorporating fast, high-displacement reflex feedback. This leads us to our third major thrust - considering biologically realistic neuron circuits instead of a limit cycle abstraction. Biological neuron circuits are incredibly diverse in practice, giving us a convincing rationale that they can aid us in our quest for flexibility. Nevertheless, that flexibility provides its own challenges. It is not currently known how most biological neuron circuits work, and little work exists that connects the principles of a neuron circuit to the principles of control theory. We begin the process of trying to bridge this gap by considering the simplest of classical controllers, PD control. We propose a simple two-neuron, two-synapse circuit based on the concept that synapses provide attenuation and a delay. We present a simulation-based method of analysis, including a smoothing algorithm, a steady-state response curve, and a system identification procedure for capturing differentiation. There will never be One True Control Method that will solve all problems. Nature's solution to a diversity of systems and situations is equally diverse. This will inspire many strategies and require a multitude of analysis tools. This thesis is my contribution of a few.

  18. Combined Use of GPS and Accelerometry Reveals Fine Scale Three-Dimensional Foraging Behaviour in the Short-Tailed Shearwater

    PubMed Central

    Berlincourt, Maud; Angel, Lauren P.; Arnould, John P. Y.

    2015-01-01

    Determining the foraging behaviour of free-ranging marine animals is fundamental for assessing their habitat use and how they may respond to changes in the environment. However, despite recent advances in bio-logging technology, collecting information on both at-sea movement patterns and activity budgets still remains difficult in small pelagic seabird species due to the constraints of instrument size. The short-tailed shearwater, the most abundant seabird species in Australia (ca 23 million individuals), is a highly pelagic procellariiform. Despite its ecological importance to the region, almost nothing is known about its at-sea behaviour, in particular, its foraging activity. Using a combination of GPS and tri-axial accelerometer data-loggers, the fine scale three-dimensional foraging behaviour of 10 breeding individuals from two colonies was investigated. Five at-sea behaviours were identified: (1) resting on water, (2) flapping flight, (3) gliding flight, (4) foraging (i.e., surface foraging and diving events), and (5) taking-off. There were substantial intra- and inter- individual variations in activity patterns, with individuals spending on average 45.8% (range: 17.1–70.0%) of time at sea resting on water and 18.2% (range: 2.3–49.6%) foraging. Individuals made 76.4 ± 65.3 dives (range: 8–237) per foraging trip (mean duration 9.0 ± 1.9 s), with dives also recorded during night-time. With the continued miniaturisation of recording devices, the use of combined data-loggers could provide us with further insights into the foraging behaviour of small procellariiforms, helping to better understand interactions with their prey. PMID:26439491

  19. Photograph of the month

    NASA Astrophysics Data System (ADS)

    2016-10-01

    Complex fold pattern superposition in the migmatite core of the Archean Yalgoo Dome, Yilgarn Craton, WA (Myers, J.S. et al., 1985. Geology 13, 778). East-trending F1 axial traces are folded around N-trending F2 axial traces, and truncated by S2, filled with axial planar leucosome. Note that most D2 leucosomes are subparallel to F2 axial traces, but not exactly located along them. Fold interference pattern types 1, 2 and 3 (Ramsay, J. G., 1967) seem to coexist in different portions of this platform. The transition between interference types is likely due to the highly non-cylindrical character of F1 folds. Furthermore, the "dome and basin" pattern, highlighted by ring-shaped layers, results from a subhorizontal cut through the culmination of F1 sheath folds. Such interpretation is supported by: (i) existence of F1 sheath folds in areas unaffected by F2 folds, and (ii) subhorizontal F2 axes, rather than the vertical observed, would be required in order to generate "dome and basin" pattern by fold superposition. The tonalite protolith of the migmatite was emplaced at c. 2.95Ga, and then deformed together with host greenstones (D1 event). Layering in the migmatite is due to alternating biotite-rich melanosomes, leucosomes bearing thin selvages, mesocratic tonalite gneiss and pegmatite to aplite veins. The pervasive, E-W trending S1 is associated with subvertical stretching lineation and is axial planar to subvertical, m- to km-scale highly sheath folds. At c. 2.75Ga, the tonalite-greenstone complex recorded a second episode of syndeformational melting (D2), accompanied by the emplacement of granites surrounding the tonalite. In migmatites, S2 occurs as N-trending, subvertical leucosomes and dykes, that are axial planar to N-trending, open to isoclinal vertical folds. 28°42‧S, 116°39‧E. Photograph© Ivan Zibra and Roberto Weinberg.

  20. Structural dynamics and aerodynamics measurements of biologically inspired flexible flapping wings.

    PubMed

    Wu, P; Stanford, B K; Sällström, E; Ukeiley, L; Ifju, P G

    2011-03-01

    Flapping wing flight as seen in hummingbirds and insects poses an interesting unsteady aerodynamic problem: coupling of wing kinematics, structural dynamics and aerodynamics. There have been numerous studies on the kinematics and aerodynamics in both experimental and computational cases with both natural and artificial wings. These studies tend to ignore wing flexibility; however, observation in nature affirms that passive wing deformation is predominant and may be crucial to the aerodynamic performance. This paper presents a multidisciplinary experimental endeavor in correlating a flapping micro air vehicle wing's aeroelasticity and thrust production, by quantifying and comparing overall thrust, structural deformation and airflow of six pairs of hummingbird-shaped membrane wings of different properties. The results show that for a specific spatial distribution of flexibility, there is an effective frequency range in thrust production. The wing deformation at the thrust-productive frequencies indicates the importance of flexibility: both bending and twisting motion can interact with aerodynamic loads to enhance wing performance under certain conditions, such as the deformation phase and amplitude. By measuring structural deformations under the same aerodynamic conditions, beneficial effects of passive wing deformation can be observed from the visualized airflow and averaged thrust. The measurements and their presentation enable observation and understanding of the required structural properties for a thrust effective flapping wing. The intended passive responses of the different wings follow a particular pattern in correlation to their aerodynamic performance. Consequently, both the experimental technique and data analysis method can lead to further studies to determine the design principles for micro air vehicle flapping wings.

  1. A Comparison of the Noise Characteristics of a Conventional Slat and Krueger Flap

    NASA Technical Reports Server (NTRS)

    Bahr, Christopher J.; Hutcheson, Florence V.; Thomas, Russell H.; Housman, Jeffery A.

    2016-01-01

    An aeroacoustic test of two types of leading-edge high-lift devices has been conducted in the NASA Langley Quiet Flow Facility. The test compares a conventional slat with a notional equivalent-mission Krueger flap. The test matrix includes points that allow for direct comparison of the conventional and Krueger devices for equivalent-mission configurations, where the two high-lift devices satisfy the same lift requirements for a free air flight path at the same cruise airfoil angle of attack. Measurements are made for multiple Mach numbers and directivity angles. Results indicate that the Krueger flap shows similar agreement to the expected power law scaling of a conventional flap, both in terms of Strouhal number and fixed frequency (as a surrogate for Helmholtz number). Directivity patterns vary depending on the specific slat and Krueger orientations. Varying the slat gap while holding overlap constant has the same influence on both the conventional slat and Krueger flap acoustic signature. Closing the gap shows dramatic reduction in levels for both devices. Varying the Krueger overlap has a different effect on the data when compared to varying the slat overlap, but analysis is limited by acoustic sources that regularly present themselves in model-scale wind tunnel testing but are not present for full-scale vehicles. The Krueger cavity is found to have some influence on level and directivity, though not as much as the other considered parameter variations. Overall, while the spectra of the two devices are different in detail, their scaling behavior for varying parameters is extremely similar.

  2. Flow structures around a flapping wing considering ground effect

    NASA Astrophysics Data System (ADS)

    Van Truong, Tien; Kim, Jihoon; Kim, Min Jun; Park, Hoon Cheol; Yoon, Kwang Joon; Byun, Doyoung

    2013-07-01

    Over the past several decades, there has been great interest in understanding the aerodynamics of flapping flight, namely the two flight modes of hovering and forward flight. However, there has been little focus on the aerodynamic characteristics during takeoff of insects. In a previous study we found that the Rhinoceros Beetle ( Trypoxylusdichotomus) takes off without jumping, which is uncommon for other insects. In this study we built a scaled-up electromechanical model of a flapping wing and investigated fluid flow around the beetle's wing model. In particular, the present dynamically scaled mechanical model has the wing kinematics pattern achieved from the real beetle's wing kinematics during takeoff. In addition, we could systematically change the three-dimensional inclined motion of the flapping model through each stroke. We used digital particle image velocimetry with high spatial resolution, and were able to qualitatively and quantitatively study the flow field around the wing at a Reynolds number of approximately 10,000. The present results provide insight into the aerodynamics and the evolution of vortical structures, as well as the ground effect experienced by a beetle's wing during takeoff. The main unsteady mechanisms of beetles have been identified and intensively analyzed as the stability of the leading edge vortex (LEV) during strokes, the delayed stall during upstroke, the rotational circulation in pronation periods, and wake capture in supination periods. Due to the ground effect, the LEV was enhanced during half downstroke, and the lift force could thus be increased to lift the beetle during takeoff. This is useful for researchers in developing a micro air vehicle that has a beetle-like flapping wing motion.

  3. [Applied anatomy study and clinical application of great saphenous veno-saphenous neurocutaneous vascular flap].

    PubMed

    Li, Zelong; Ding, Zihai; Wang, Peixin; Xie, Yibo; Zeng, Bo

    2006-03-01

    To provide the anatomic basis for defect repair of the knee, leg, foot and ankle with great saphenous veno-saphenous neurocutaneous vascular island flaps. The origin, diameter, branches, distribution and anastomoses of the saphenous artery and saphenous neurocutaneous vascular were observed on 20 sides of adult leg specimens and 4 fresh cadaver voluntary legs. Another 4 fresh cadaver voluntary legs were radiographed with a soft X-ray system after the intravenous injection of Vermilion and cross-sections under profound fascial, other hand, micro-anatomic examination was also performed in these 4 fresh cadaver legs. The soft tissue defects in lower extremity, upper extremity, heel or Hucou in hand were repaired with the proximal or distal pedicle flaps or free flaps in 18 patients (12 males and 6 females,aging from 7 to 53 years). The defect was caused by trauma, tumour, ulcer and scar. The locations were Hucou (1 case), upper leg (3 cases), lower extremity and heal (14 cases). Of then, 7 cases were complicated by bone exposure, 3 cases by tendon exposure and 1 case by steel espouse, the defect size were 4 cm x 4 cm to 7 cm x 13 cm. The flap sizes were 4 cm x 6 cm to 8 cm x 15 cm, which pedicle length was 8-11 cm with 2.5-4.0 cm fascia and 1-2 cm skin at width. Genus descending genicular artery began from 9.33 +/- 0.81 cm away from upper the condyles medialis, it branched saphenous artery accompanying saphenous nerve descendent. And saphenous artery reached the surface of the skin 7.21 +/- 0.82 cm away from lower the condyles medialis, and anastomosed with the branches of tibialis posterior artery, like "Y" or "T" pattern. The chain linking system of arteries were found accompanying along the great saphenous vein as saphenous nerve, and then a axis blood vessel was formed. The small artery of only 0.05-0.10 mm in diameter, distributed around the great saphenous vein within 5-8 mm and arranged parallelly along the vein like water wave in soft X-ray film. All proximal flaps, distal pedicle flaps and free flaps survived well. The appearance, sensation and function were satisfactory in 14 patients after a follow-up of 6-12 months. The great saphenous vein as well as saphenous neurocutaneous has a chain linking system vascular net. A flap with the vascular net can be transplanted by free, by reversed pedicle, or by direct pedicle to repair the wound of upper leg and foot. A superficial vein-superficial neurocutaneous vascular flap with abundance blood supply and without sacrificing a main artery is a favourite method in repair of soft tissue defects in foot and lower extremity.

  4. 3D structured illumination microscopy using an incoherent illumination system based on a Fresnel biprism

    NASA Astrophysics Data System (ADS)

    Shabani, H.; Doblas, A.; Saavedra, G.; Preza, C.

    2018-02-01

    Three-dimensional (3D) structured illumination (SI) patterns that include lateral and axial variations have attracted more attention recently as their use in fluorescence microscope enhances the 3D resolution of the native imaging system. 3D SI patterns have already been created by interfering three mutually-coherent waves using a diffraction grating or some electro-optical devices such as spatial light modulators. Here, an interesting approach to generate a 3D SI pattern of tunable modulation frequency is shown. Our proposed illumination system is based on the incoherent illumination of a Fresnel biprism using several equidistant linear sources (i.e., slits). Previously, we investigated and compared numerically this tunable SI microscopy (SIM) system with the one achieved with three-wave interference. In this contribution, we implement our proposed incoherent 3D SIM system of tunable-frequency in an open-setup. We evaluate the axial confinement of the illumination pattern obtained with this system by recording the SI pattern using a mirror sample and different number of slits and compare these data with simulation results. Moreover, we verify that with a higher number of slits used, the axial confinement of the pattern increases, and consequently, the system's optical sectioning capability improves.

  5. Vascular endothelial growth factor signaling regulates the segregation of artery and vein via ERK activity during vascular development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Se-Hee; Schmitt, Christopher E.; Woolls, Melissa J.

    Highlights: ► VEGF-A signaling regulates the segregation of axial vessels. ► VEGF-A signaling is mediated by PKC and ERK in this process. ► Ectopic activation of ERK is sufficient to rescue defects in vessel segregation. -- Abstract: Segregation of two axial vessels, the dorsal aorta and caudal vein, is one of the earliest patterning events occur during development of vasculature. Despite the importance of this process and recent advances in our understanding on vascular patterning during development, molecular mechanisms that coordinate the segregation of axial vessels remain largely elusive. In this report, we find that vascular endothelial growth factor-A (Vegf-A)more » signaling regulates the segregation of dorsal aorta and axial vein during development. Inhibition of Vegf-A pathway components including ligand Vegf-A and its cognate receptor Kdrl, caused failure in segregation of axial vessels in zebrafish embryos. Similarly, chemical inhibition of Mitogen-activated protein kinase kinase (Map2k1)/Extracellular-signal-regulated kinases (Erk) and phosphatidylinositol 3-kinases (PI3 K), which are downstream effectors of Vegf-A signaling pathway, led to the fusion of two axial vessels. Moreover, we find that restoring Erk activity by over-expression of constitutively active MEK in embryos with a reduced level of Vegf-A signaling can rescue the defects in axial vessel segregation. Taken together, our data show that segregation of axial vessels requires the function of Vegf-A signaling, and Erk may function as the major downstream effector in this process.« less

  6. Automated Detection of Stereotypical Motor Movements

    ERIC Educational Resources Information Center

    Goodwin, Matthew S.; Intille, Stephen S.; Albinali, Fahd; Velicer, Wayne F.

    2011-01-01

    To overcome problems with traditional methods for measuring stereotypical motor movements in persons with Autism Spectrum Disorders (ASD), we evaluated the use of wireless three-axis accelerometers and pattern recognition algorithms to automatically detect body rocking and hand flapping in children with ASD. Findings revealed that, on average,…

  7. Axial jet mixing of ethanol in spherical containers during weightlessness

    NASA Technical Reports Server (NTRS)

    Audelott, J. C.

    1976-01-01

    An experimental program was conducted to examine the liquid flow patterns that result from the axial jet mixing of ethanol in 10-centimeter-diameter spherical containers in weightlessness. Complete liquid circulation flow patterns were easily established in containers that were less than half full of liquid, while for higher liquid fill conditions, vapor was drawn into the inlet of the simulated mixer unit. Increasing the liquid-jet or lowering the position at which the liquid jet entered the container caused increasing turbulence and bubble formation.

  8. Axial jet mixing of ethanol in cylindrical containers during weightlessness

    NASA Technical Reports Server (NTRS)

    Aydelott, J. C.

    1979-01-01

    An experimental program was conducted to examine the liquid flow patterns that result from the axial jet mixing of ethanol in 10-centimeter-diameter cylindrical tanks in weightlessness. A convex hemispherically ended tank and two Centaur liquid-hydrogen-tank models were used for the study. Four distinct liquid flow patterns were observed to be a function of the tank geometry, the liquid-jet velocity, the volume of liquid in the tank, and the location of the tube from which the liquid jet exited.

  9. Three-dimensional, high-resolution skeletal kinematics of the avian wing and shoulder during ascending flapping flight and uphill flap-running.

    PubMed

    Baier, David B; Gatesy, Stephen M; Dial, Kenneth P

    2013-01-01

    Past studies have shown that birds use their wings not only for flight, but also when ascending steep inclines. Uphill flap-running or wing-assisted incline running (WAIR) is used by both flight-incapable fledglings and flight-capable adults to retreat to an elevated refuge. Despite the broadly varying direction of travel during WAIR, level, and descending flight, recent studies have found that the basic wing path remains relatively invariant with reference to gravity. If so, joints undergo disparate motions to maintain a consistent wing path during those specific flapping modes. The underlying skeletal motions, however, are masked by feathers and skin. To improve our understanding of the form-functional relationship of the skeletal apparatus and joint morphology with a corresponding locomotor behavior, we used XROMM (X-ray Reconstruction of Moving Morphology) to quantify 3-D skeletal kinematics in chukars (Alectoris chukar) during WAIR (ascending with legs and wings) and ascending flight (AF, ascending with wings only) along comparable trajectories. Evidence here from the wing joints demonstrates that the glenohumeral joint controls the vast majority of wing movements. More distal joints are primarily involved in modifying wing shape. All bones are in relatively similar orientations at the top of upstroke during both behaviors, but then diverge through downstroke. Total excursion of the wing is much smaller during WAIR and the tip of the manus follows a more vertical path. The WAIR stroke appears "truncated" relative to ascending flight, primarily stemming from ca. 50% reduction in humeral depression. Additionally, the elbow and wrist exhibit reduced ranges of angular excursions during WAIR. The glenohumeral joint moves in a pattern congruent with being constrained by the acrocoracohumeral ligament. Finally, we found pronounced lateral bending of the furcula during the wingbeat cycle during ascending flight only, though the phasic pattern in chukars is opposite of that observed in starlings (Sturnus vulgaris).

  10. Full-field, nonscanning, optical imaging for perfusion indication

    NASA Astrophysics Data System (ADS)

    Chou, Nee-Yin; Winchester, L. W., Jr.; Naramore, W. J.; Alley, M. S.; Lesnick, A. J.

    2010-04-01

    Laser speckle imaging (LSI) has been gaining popularity for the past few years. Like other optical imaging modalities such as optical coherence tomography (OCT), orthogonal polarization spectroscopy (OPS), and laser Doppler imaging (LDI), LSI utilizes nonionizing radiation. In LSI, blood flow velocity is obtained by analyzing, temporally or spatially, laser speckle (LS) patterns generated when an expanded laser beam illuminates the tissue. The advantages of LSI are that it is fast, does not require scanning, and provides full-field LS images to extract realtime, quantitative hemodynamic information of subtle changes in the tissue vasculature. For medical applications, LSI has been used for obtaining blood velocities in human retina, skin flaps, wounds, and cerebral and sublingual areas. When coupled with optical fibers, LSI can be used for endoscopic measurements for a variety of applications. This paper describes the application of LSI in retinal, sublingual, and skin flap measurements. Evaluation of retinal hemodynamics provides very important diagnostic information, since the human retina offers direct optical access to both the central nervous system (CNS) and afferent and efferent CNS vasculature. The performance of an LSI-based fundus imager for measuring retinal hemodynamics is presented. Sublingual microcirculation may have utility for sepsis indication, since inherent in organ injury caused by sepsis is a profound change in microvascular hemodynamics. Sublingual measurement results using an LSI scope are reported. A wound imager for imaging LS patterns of wounds and skin flaps is described, and results are presented.

  11. Bridgman Growth of GeSi Alloys in a Static Magnetic Field

    NASA Technical Reports Server (NTRS)

    Volz, M. P.; Szofran, F. R.; Vujisic, L.; Motakef, S.

    1998-01-01

    Ge(0.95)Si(0.050 alloy crystals have been grown by the vertical Bridgman technique, both with and without an axial 5 Tesla magnetic field. The crystals were processed in a constant axial thermal gradient and the effects of graphite, hot pressed boron nitride, and pyrolitic boron nitride ampoule materials on interface shapes and macrosegregation profiles were investigated. The sample grown in a graphite ampoule at 5 Tesla exhibited a macroscopic axial concentration profile close to that of complete mixing and strong striation patterns. In samples grown in boron nitride ampoules, both with and without a 5 Tesla magnetic field applied, measured macroscopic axial concentration profiles were intermediate between those expected for a completely mixed melt and diffusion-controlled growth, and striation patterns were also observed. Possible explanations for the apparent inability of the magnetic field to reduce the flow velocities to below the growth velocities are discussed, and results of growth experiments in pyrolitic boron nitride ampoules are also described.

  12. Rapid and noncontact photoacoustic tomography imaging system using an interferometer with high-speed phase modulation technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Jun; Tang, Zhilie; Wu, Yongbo

    2015-04-15

    We designed, fabricated, and tested a rapid and noncontact photoacoustic tomography (PAT) imaging system using a low-coherence interferometer with high-speed phase modulation technique. Such a rapid and noncontact probing system can greatly decrease the time of imaging. The proposed PAT imaging system is experimentally verified by capturing images of a simulated tissue sample and the blood vessels within the ear flap of a mouse (pinna) in vivo. The axial and lateral resolutions of the system are evaluated at 45 and ∼15 μm, respectively. The imaging depth of the system is 1 mm in a special phantom. Our results show thatmore » the proposed system opens a promising way to realize noncontact, real-time PAT.« less

  13. Free-style puzzle flap: the concept of recycling a perforator flap.

    PubMed

    Feng, Kuan-Ming; Hsieh, Ching-Hua; Jeng, Seng-Feng

    2013-02-01

    Theoretically, a flap can be supplied by any perforator based on the angiosome theory. In this study, the technique of free-style perforator flap dissection was used to harvest a pedicled or free skin flap from a previous free flap for a second difficult reconstruction. The authors call this a free-style puzzle flap. For the past 3 years, the authors treated 13 patients in whom 12 pedicled free-style puzzle flaps were harvested from previous redundant free flaps and recycled to reconstruct soft-tissue defects at various anatomical locations. One free-style free puzzle flap was harvested from a previous anterolateral thigh flap for buccal cancer to reconstruct a foot defect. Total flap survival was attained in 12 of 13 flaps. One transferred flap failed completely. This patient had received postoperative radiotherapy after the initial cancer ablation and free anterolateral thigh flap reconstruction. Another free flap was used to close and reconstruct the wound. All the donor sites could be closed primarily. The free-style puzzle flap, harvested from a previous redundant free flap and used as a perforator flap to reconstruct a new defect, has proven to be versatile and reliable. When indicated, it is an alternative donor site for further reconstruction of soft-tissue defects.

  14. Artificial insect wings of diverse morphology for flapping-wing micro air vehicles.

    PubMed

    Shang, J K; Combes, S A; Finio, B M; Wood, R J

    2009-09-01

    The development of flapping-wing micro air vehicles (MAVs) demands a systematic exploration of the available design space to identify ways in which the unsteady mechanisms governing flapping-wing flight can best be utilized for producing optimal thrust or maneuverability. Mimicking the wing kinematics of biological flight requires examining the potential effects of wing morphology on flight performance, as wings may be specially adapted for flapping flight. For example, insect wings passively deform during flight, leading to instantaneous and potentially unpredictable changes in aerodynamic behavior. Previous studies have postulated various explanations for insect wing complexity, but there lacks a systematic approach for experimentally examining the functional significance of components of wing morphology, and for determining whether or not natural design principles can or should be used for MAVs. In this work, a novel fabrication process to create centimeter-scale wings of great complexity is introduced; via this process, a wing can be fabricated with a large range of desired mechanical and geometric characteristics. We demonstrate the versatility of the process through the creation of planar, insect-like wings with biomimetic venation patterns that approximate the mechanical properties of their natural counterparts under static loads. This process will provide a platform for studies investigating the effects of wing morphology on flight dynamics, which may lead to the design of highly maneuverable and efficient MAVs and insight into the functional morphology of natural wings.

  15. An experimental investigation of multi-element airfoil ice accretion and resulting performance degradation

    NASA Technical Reports Server (NTRS)

    Potapczuk, Mark G.; Berkowitz, Brian M.

    1989-01-01

    An investigation of the ice accretion pattern and performance characteristics of a multi-element airfoil was undertaken in the NASA Lewis 6- by 9-Foot Icing Research Tunnel. Several configurations of main airfoil, slat, and flaps were employed to examine the effects of ice accretion and provide further experimental information for code validation purposes. The text matrix consisted of glaze, rime, and mixed icing conditions. Airflow and icing cloud conditions were set to correspond to those typical of the operating environment anticipated tor a commercial transport vehicle. Results obtained included ice profile tracings, photographs of the ice accretions, and force balance measurements obtained both during the accretion process and in a post-accretion evaluation over a range of angles of attack. The tracings and photographs indicated significant accretions on the slat leading edge, in gaps between slat or flaps and the main wing, on the flap leading-edge surfaces, and on flap lower surfaces. Force measurments indicate the possibility of severe performance degradation, especially near C sub Lmax, for both light and heavy ice accretion and performance analysis codes presently in use. The LEWICE code was used to evaluate the ice accretion shape developed during one of the rime ice tests. The actual ice shape was then evaluated, using a Navier-Strokes code, for changes in performance characteristics. These predicted results were compared to the measured results and indicate very good agreement.

  16. Writing forces associated with four pencil grasp patterns in grade 4 children.

    PubMed

    Schwellnus, Heidi; Carnahan, Heather; Kushki, Azadeh; Polatajko, Helene; Missiuna, Cheryl; Chau, Tom

    2013-01-01

    OBJECTIVE. We investigated differences in handwriting kinetics, speed, and legibility among four pencil grasps after a 10-min copy task. METHOD. Seventy-four Grade 4 students completed a handwriting assessment before and after a copy task. Grip and axial forces were measured with an instrumented stylus and force-sensitive tablet. We used multiple linear regression to analyze the relationship between grasp pattern and grip and axial forces. RESULTS. We found no kinetic differences among grasps, whether considered individually or grouped by the number of fingers on the barrel. However, when grasps were grouped according to the thumb position, the adducted grasps exhibited higher mean grip and axial forces. CONCLUSION. Grip forces were generally similar across the different grasps. Kinetic differences resulting from thumb position seemed to have no bearing on speed and legibility. Interventions for handwriting difficulties should focus more on speed and letter formation than on grasp pattern. Copyright © 2013 by the American Occupational Therapy Association, Inc.

  17. "Reading man flap" design for reconstruction of circular infraorbital and malar skin defects.

    PubMed

    Seyhan, Tamer; Caglar, Baris

    2008-11-01

    Surgical complications such as lid retraction and ectropion from graft or flap scar contracture make reconstruction of skin defects in the malar and infraorbital regions challenging. A new flap design, the reading man flap, was used to overcome these problems. The Limberg and bilobed flap were compared with the reading man flap. The reading man flap consists mainly of a superiorly based quadrangular flap and an inferiorly based triangular flap. Malar and infraorbital circular skin defects measuring 14 x 14 to 40 x 40 mm were reconstructed with a reading man flap in 13 patients. The defects occurred after basal cell carcinoma in all patients. The Limberg flap, bilobed flap, and reading man flap were planned for same-sized defects on the abdominoplasty resection material. The results were compared in terms of total scar area, scar length, and total healthy skin area discarded. When comparing the 3 flap designs, the reading man flap was the most suitable flap in terms of total scar area and length. The reading man flap can be used to reconstruct malar and infraorbital circular defects with good cosmetic results and without creating any tractional forces to the eyelids.

  18. INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP TECHNIQUE FOR TREATMENT OF FULL-THICKNESS MACULAR HOLES: A COMPARATIVE STUDY IN A LARGE SERIES OF PATIENTS.

    PubMed

    Rizzo, Stanislao; Tartaro, Ruggero; Barca, Francesco; Caporossi, Tomaso; Bacherini, Daniela; Giansanti, Fabrizio

    2017-12-08

    The inverted flap (IF) technique has recently been introduced in macular hole (MH) surgery. The IF technique has shown an increase of the success rate in the case of large MHs and in MHs associated with high myopia. This study reports the anatomical and functional results in a large series of patients affected by MH treated using pars plana vitrectomy and gas tamponade combined with internal limiting membrane (ILM) peeling or IF. This is a retrospective, consecutive, nonrandomized comparative study of patients affected by idiopathic or myopic MH treated using small-gauge pars plana vitrectomy (25- or 23-gauge) between January 2011 and May 2016. The patients were divided into two groups according to the ILM removal technique (complete removal vs. IF). A subgroup analysis was performed according to the MH diameter (MH < 400 µm and MH ≥ 400 µm), axial length (AL < 26 mm and AL ≥ 26 mm), and the presence of chorioretinal atrophy in the macular area (present or absent). We included 620 eyes of 570 patients affected by an MH, 300 patients underwent pars plana vitrectomy and ILM peeling and 320 patients underwent pars plana vitrectomy and IF. Overall, 84.94% of the patients had complete anatomical success characterized by MH closure after the operation. In particular, among the patients who underwent only ILM peeling the closure rate was 78.75%; among the patients who underwent the IF technique, it was 91.93% (P = 0.001); and among the patients affected by full-thickness MH ≥400 µm, success was achieved in 95.6% of the cases in the IF group and in 78.6% in the ILM peeling group (P = 0.001); among the patients with an axial length ≥26 mm, success was achieved in 88.4% of the cases in the IF group and in 38.9% in the ILM peeling group (P = 0.001). Average preoperative best-corrected visual acuity was 0.77 (SD = 0.32) logarithm of the minimum angle of resolution (20/118 Snellen) in the peeling group and 0.74 (SD = 0.33) logarithm of the minimum angle of resolution (20/110 Snellen) in the IF group (P = 0.31). Mean postoperative best-corrected visual acuity was 0.52 (SD = 0.42) logarithm of the minimum angle of resolution (20/66 Snellen) in the peeling group and 0.43 (SD = 0.31) logarithm of the minimum angle of resolution (20/53 Snellen) in the IF group (P = 0.003). Vitrectomy associated with the inverted ILM flap technique seems to be effective surgery for idiopathic and myopic large MHs, improving both functional and anatomical outcomes.

  19. Four-flap Breast Reconstruction: Bilateral Stacked DIEP and PAP Flaps

    PubMed Central

    Mayo, James L.; Allen, Robert J.

    2015-01-01

    Background: In cases of bilateral breast reconstruction when the deep inferior epigastric perforator (DIEP) free flap alone does not provide sufficient volume for body-specific reconstruction, stacking each DIEP flap with a second free flap will deliver added volume and maintain a purely autologous reconstruction. Stacking the profunda artery perforator (PAP) flap with the DIEP flap offers favorable aesthetics and ideal operative efficiency. We present the indications, technique, and outcomes of our experience with 4-flap breast reconstruction using stacked DIEP/PAP flaps. Methods: The authors performed 4-flap DIEP/PAP breast reconstruction in 20 patients who required bilateral reconstruction without adequate single donor flap volume. The timing of reconstruction, average mastectomy/flap weights, and operative time are reported. Complications reviewed include fat necrosis, dehiscence, hematoma, seroma, mastectomy flap necrosis, and flap loss. Results: Twenty patients underwent 4-flap DIEP/PAP breast reconstruction. Surgical time averaged 7 hours and 20 minutes. The primary recipient vessels were the antegrade and retrograde internal mammary vessels. No flap losses occurred. Complications included 1 hematoma, 1 incidence of arterial and venous thrombosis successfully treated with anastomotic revision, 1 incidence of thigh donor site dehiscence, and 3 episodes of minor mastectomy skin flap necrosis. Conclusions: Four-flap breast reconstruction is a favorable autologous reconstructive option for patients requiring bilateral reconstruction without adequate single donor flap volume. Stacking DIEP/PAP flaps as described is both safe and efficient. Furthermore, this combination provides superior aesthetics mirroring the natural geometry of the breast. Bilateral stacked DIEP/PAP flaps represent our first choice for breast reconstruction in this patient population. PMID:26090273

  20. Free Boomerang-shaped Extended Rectus Abdominis Myocutaneous flap: The longest possible skin/myocutaneous free flap for soft tissue reconstruction of extremities.

    PubMed

    Koul, Ashok R; Nahar, Sushil; Prabhu, Jagdish; Kale, Subhash M; Kumar, Praveen H P

    2011-09-01

    A soft tissue defect requiring flap cover which is longer than that provided by the conventional "long" free flaps like latissimus dorsi (LD) and anterolateral thigh (ALT) flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free "Boomerang-shaped" Extended Rectus Abdominis Myocutaneous (BERAM) flap. This flap is the slightly modified and "free" version of a similar flap described by Ian Taylor in 1983. This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs.

  1. Isolated scaphoid dislocation associated with axial carpal dissociation: an unusual injury report.

    PubMed

    Horton, Todd; Shin, Alexander Y; Cooney, William P

    2004-11-01

    We present a report of a patient with an isolated scaphoid dislocation associated with a hyperextension and axial loading injury of the carpus required a careful and extensive clinical and radiographic evaluation leading to surgical intervention to reduce and stabilize the scaphoid and to reduce and hold internally the axial carpal injury. Knowledge of the anatomy and the potential injury patterns of the carpus will aid the hand surgeon with injury recognition and proper treatment.

  2. Glycoconjugate distribution in early human notochord and axial mesenchyme.

    PubMed

    Götz, W; Quondamatteo, F

    2001-02-01

    Glycosylation patterns of cells and tissues give insights into spatially and temporally regulated developmental processes and can be detected histochemically using plant lectins with specific affinities for sugar moieties. The early development of the vertebral column in man is a process which has never been investigated by lectin histochemistry. Therefore, we studied binding of several lectins (AIA, Con A, GSA II, LFA, LTA, PNA, RCA I, SBA, SNA, WGA) in formaldehyde-fixed sections of the axial mesenchyme of 5 human embryos in Carnegie stages 12-15. During these developmental stages, an unsegmented mesenchyme covers the notochord. Staining patterns did not show striking temporal variations except for SBA which stained the cranial axial mesenchyme only in the early stage 12 embryo and for PNA, of which the staining intensity in the mesenchyme decreased with age. The notochord appeared as a highly glycosylated tissue. Carbohydrates detected may correspond to adhesion molecules or to secreted substances like proteoglycans or proteins which could play an inductive role, for example, for the neural tube. The axial perinotochordal unsegmented mesenchyme showed strong PNA binding. Therefore, its function as a PNA-positive "barrier" tissue is discussed. The endoderm of the primitive gut showed a lectin-binding pattern that was similar to that of the notochord, which may correlate with interactions between these tissues during earlier developmental stages.

  3. Progress in incompressible Navier-Stokes computations for propulsion flows and its dual-use applications

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin

    1995-01-01

    Development of an incompressible Navier-Stokes solution procedure was performed for the analysis of a liquid rocket engine pump components and for the mechanical heart assist devices. The solution procedure for the propulsion systems is applicable to incompressible Navier-Stokes flows in a steadily rotating frame of reference for any general complex configurations. The computer codes were tested on different complex configurations such as liquid rocket engine inducer and impellers. As a spin-off technology from the turbopump component simulations, the flow analysis for an axial heart pump was conducted. The baseline Left Ventricular Assist Device (LVAD) design was improved by adding an inducer geometry by adapting from the liquid rocket engine pump. The time-accurate mode of the incompressible Navier-Stokes code was validated with flapping foil experiment by using different domain decomposition methods. In the flapping foil experiment, two upstream NACA 0025 foils perform high-frequency synchronized motion and generate unsteady flow conditions for a downstream larger stationary foil. Fairly good agreement was obtained between unsteady experimental data and numerical results from two different moving boundary procedures. Incompressible Navier-Stokes code (INS3D) has been extended for heat transfer applications. The temperature equation was written for both forced and natural convection phenomena. Flow in a square duct case was used for the validation of the code in both natural and forced convection.

  4. Free Boomerang-shaped Extended Rectus Abdominis Myocutaneous flap: The longest possible skin/myocutaneous free flap for soft tissue reconstruction of extremities

    PubMed Central

    Koul, Ashok R.; Nahar, Sushil; Prabhu, Jagdish; Kale, Subhash M.; Kumar, Praveen H. P.

    2011-01-01

    Background: A soft tissue defect requiring flap cover which is longer than that provided by the conventional “long” free flaps like latissimus dorsi (LD) and anterolateral thigh (ALT) flap is a challenging problem. Often, in such a situation, a combination of flaps is required. Over the last 3 years, we have managed nine such defects successfully with a free “Boomerang-shaped” Extended Rectus Abdominis Myocutaneous (BERAM) flap. This flap is the slightly modified and “free” version of a similar flap described by Ian Taylor in 1983. Materials and Methods: This is a retrospective study of patients who underwent free BERAM flap reconstruction of soft tissue defects of extremity over the last 3 years. We also did a clinical study on 30 volunteers to compare the length of flap available using our design of BERAM flap with the maximum available flap length of LD and ALT flaps, using standard markings. Results: Our clinical experience of nine cases combined with the results of our clinical study has confirmed that our design of BERAM flap consistently provides a flap length which is 32.6% longer than the standard LD flap and 42.2% longer than the standard ALT flap in adults. The difference is even more marked in children. The BERAM flap is consistently reliable as long as the distal end is not extended beyond the mid-axillary line. Conclusion: BERAM flap is simple in design, easy to harvest, reliable and provides the longest possible free skin/myocutaneous flap in the body. It is a useful new alternative for covering long soft tissue defects in the limbs. PMID:22279271

  5. Analysis of HLA-B15 and HLA-B27 in spondyloarthritis with peripheral and axial clinical patterns

    PubMed Central

    Londono, John; Santos, Ana Maria; Peña, Paola; Calvo, Enrique; Espinosa, Luis R; Reveille, John D; Vargas-Alarcon, Gilberto; Jaramillo, Carlos A; Valle-Oñate, Rafael; Avila, Mabel; Romero, Consuelo; Medina, Juan F

    2015-01-01

    Objective Human leucocyte antigen (HLA) B27 and HLA-B15 are associated with spondyloarthritis (SpA). Recent Assessment of SpondyloArthritis international Society (ASAS) criteria emphasise a distinction between SpA with axial and peripheral patterns. We analysed whether HLA-A, HLA-B and HLA-DRB1 alleles could associate with these patterns. Methods We studied 100 healthy individuals and 178 patients with SpA according to European Spondyloarthropathy Study Group (ESSG) criteria. Patients were then classified according to ASAS criteria, the axial spondyloarthritis pattern (axSpA) being defined by ascertained sacroiliitis and the peripheral pattern (pSpA) by enthesitis and/or arthritis in extremities. A combined ax/p pattern was also considered. Results Only HLA-B27 and HLA-B15 alleles were associated with SpA. ASAS criteria for axSpA were met in 152 patients (12 with isolated axSpA and 140 with a combined ax/p patterns). When the ASAS peripheral criteria were applied, 161 patients met these criteria (13 with isolated pSpA and 148 with a combined ax/p pattern). HLA-B27 was found in 83% of patients with axSpA and 43% of ax/pSpA patients according to axASAS. HLA-B27 occurred in 7% controls but not in any patient with isolated pSpA. HLA-B15 was encountered in 31% of patients with isolated pSpA and 20% of ax/pSpA patients according to pASAS criteria. Moreover, 2 healthy controls, but none of our patients with isolated axSpA were positive for HLA-B15. Conclusions Our data suggest that the presence of HLA-B15 favours the development of isolated/combined peripheral rather than isolated axSpA, while HLA-B27 promotes an isolated/combined axial disease and excludes a peripheral pattern. HLA-B15 should be considered in addition to HLA-B27 when diagnosing patients with SpA according to ASAS criteria. PMID:26560062

  6. The possibility for use of venous flaps in plastic surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baytinger, V. F., E-mail: baitinger@mail.tomsknet.ru; Kurochkina, O. S., E-mail: kurochkinaos@yandex.ru; Selianinov, K. V.

    2015-11-17

    The use of venous flaps is controversial. The mechanism of perfusion of venous flaps is still not fully understood. The research was conducted on 56 white rats. In our experimental work we studied two different models of venous flaps: pedicled venous flap (PVF) and pedicled arterialized venous flap (PAVF). Our results showed that postoperative congestion was present in all flaps. However 66.7% of all pedicled venous flaps and 100% of all pedicled arterialized venous flaps eventually survived. Histological examination revealed that postoperatively the blood flow in the skin of the pedicled arterialized venous flap became «re-reversed» again; there were nomore » differences between mechanism of survival of venous flaps and other flaps. On the 7-14th day in the skin of all flaps were processes of neoangiogenesis and proliferation. Hence the best scenario for the clinical use of venous flaps unfolds when both revascularization and skin coverage are required.« less

  7. Evolution of the axial system in craniates: morphology and function of the perivertebral musculature

    PubMed Central

    2011-01-01

    The axial musculoskeletal system represents the plesiomorphic locomotor engine of the vertebrate body, playing a central role in locomotion. In craniates, the evolution of the postcranial skeleton is characterized by two major transformations. First, the axial skeleton became increasingly functionally and morphologically regionalized. Second, the axial-based locomotion plesiomorphic for craniates became progressively appendage-based with the evolution of extremities in tetrapods. These changes, together with the transition to land, caused increased complexity in the planes in which axial movements occur and moments act on the body and were accompanied by profound changes in axial muscle function. To increase our understanding of the evolutionary transformations of the structure and function of the perivertebral musculature, this review integrates recent anatomical and physiological data (e.g., muscle fiber types, activation patterns) with gross-anatomical and kinematic findings for pivotal craniate taxa. This information is mapped onto a phylogenetic hypothesis to infer the putative character set of the last common ancestor of the respective taxa and to conjecture patterns of locomotor and muscular evolution. The increasing anatomical and functional complexity in the muscular arrangement during craniate evolution is associated with changes in fiber angulation and fiber-type distribution, i.e., increasing obliqueness in fiber orientation and segregation of fatigue-resistant fibers in deeper muscle regions. The loss of superficial fatigue-resistant fibers may be related to the profound gross anatomical reorganization of the axial musculature during the tetrapod evolution. The plesiomorphic function of the axial musculature -mobilization- is retained in all craniates. Along with the evolution of limbs and the subsequent transition to land, axial muscles additionally function to globally stabilize the trunk against inertial and extrinsic limb muscle forces as well as gravitational forces. Associated with the evolution of sagittal mobility and a parasagittal limb posture, axial muscles in mammals also stabilize the trunk against sagittal components of extrinsic limb muscle action as well as the inertia of the body's center of mass. Thus, the axial system is central to the static and dynamic control of the body posture in all craniates and, in gnathostomes, additionally provides the foundation for the mechanical work of the appendicular system. PMID:21306656

  8. Fluid dynamics of flapping aquatic flight in the bird wrasse: three-dimensional unsteady computations with fin deformation.

    PubMed

    Ramamurti, Ravi; Sandberg, William C; Löhner, Rainald; Walker, Jeffrey A; Westneat, Mark W

    2002-10-01

    Many fishes that swim with the paired pectoral fins use fin-stroke parameters that produce thrust force from lift in a mechanism of underwater flight. These locomotor mechanisms are of interest to behavioral biologists, biomechanics researchers and engineers. In the present study, we performed the first three-dimensional unsteady computations of fish swimming with oscillating and deforming fins. The objective of these computations was to investigate the fluid dynamics of force production associated with the flapping aquatic flight of the bird wrasse Gomphosus varius. For this computational work, we used the geometry of the wrasse and its pectoral fin, and previously measured fin kinematics, as the starting points for computational investigation of three-dimensional (3-D) unsteady fluid dynamics. We performed a 3-D steady computation and a complete set of 3-D quasisteady computations for a range of pectoral fin positions and surface velocities. An unstructured, grid-based, unsteady Navier-Stokes solver with automatic adaptive remeshing was then used to compute the unsteady flow about the wrasse through several complete cycles of pectoral fin oscillation. The shape deformation of the pectoral fin throughout the oscillation was taken from the experimental kinematics. The pressure distribution on the body of the bird wrasse and its pectoral fins was computed and integrated to give body and fin forces which were decomposed into lift and thrust. The velocity field variation on the surface of the wrasse body, on the pectoral fins and in the near-wake was computed throughout the swimming cycle. We compared our computational results for the steady, quasi-steady and unsteady cases with the experimental data on axial and vertical acceleration obtained from the pectoral fin kinematics experiments. These comparisons show that steady state computations are incapable of describing the fluid dynamics of flapping fins. Quasi-steady state computations, with correct incorporation of the experimental kinematics, are useful when determining trends in force production, but do not provide accurate estimates of the magnitudes of the forces produced. By contrast, unsteady computations about the deforming pectoral fins using experimentally measured fin kinematics were found to give excellent agreement, both in the time history of force production throughout the flapping strokes and in the magnitudes of the generated forces.

  9. Experimental Study of Wake / Flap Interaction Noise and the Reduction of Flap Side Edge Noise

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V.; Stead, Daniel J.; Plassman, Gerald E.

    2016-01-01

    The effects of the interaction of a wake with a half-span flap on radiated noise are examined. The incident wake is generated by bars of various widths and lengths or by a simplified landing gear model. Single microphone and phased array measurements are used to isolate the effects of the wake interaction on the noise radiating from the flap side edge and flap cove regions. The effects on noise of the wake generator's geometry and relative placement with respect to the flap are assessed. Placement of the wake generators upstream of the flap side edge is shown to lead to the reduction of flap side edge noise by introducing a velocity deficit and likely altering the instabilities in the flap side edge vortex system. Significant reduction in flap side edge noise is achieved with a bar positioned directly upstream of the flap side edge. The noise reduction benefit is seen to improve with increased bar width, length and proximity to the flap edge. Positioning of the landing gear model upstream of the flap side edge also leads to decreased flap side edge noise. In addition, flap cove noise levels are significantly lower than when the landing gear is positioned upstream of the flap mid-span. The impact of the local flow velocity on the noise radiating directly from the landing gear is discussed. The effects of the landing gear side-braces on flap side edge, flap cove and landing gear noise are shown.

  10. Evaluation of the cranial rectus abdominus muscle pedicle flap as a blood supply for the caudal superficial epigastric skin flap in dogs.

    PubMed

    Degner, D A; Walshaw, R; Arnoczky, S P; Smith, R J; Patterson, J S; Degner, L A; Hamaide, A; Rosenstein, D

    1996-01-01

    This study evaluates the cranial rectus abdominus muscle pedicle flap as the sole blood supply for the caudal superficial epigastric skin flap. This flap was composed of a cranially based rectus abdominus muscle pedicle flap that was attached to the caudal superficial epigastric island skin flap (including mammary glands 2 to 5) via the pudendoepigastric trunk. Selective angiography of the cranial epigastric artery in eight cadaver dogs proved that the arterial vasculature in the cranial rectus abdominus was contiguous with that in the caudal superficial epigastric skin flap. In the live dog study, three of six of the flaps failed because of venous insufficiency. Necrosis of mammary gland 2 occurred in two of six flaps. One of six flaps survived with the exception of the cranial most aspect of mammary gland 2. Angiography of the cranial epigastric artery proved that arterial blood supply to these flaps was intact. Histological evaluation of the failed flaps showed full-thickness necrosis of the skin and subcutaneous tissues, the presence of severe congestion, and venous thrombosis. Retrograde venous blood flow through the flap was inconsistent, and hence resulted in failure of this myocutaneous flap. Use of this flap for clinical wound reconstruction cannot be recommended.

  11. Ultra-wideband, omni-directional, low distortion coaxial antenna

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eubanks, Travis Wayne; Gibson, Christopher Lawrence

    An antenna for producing an omni-directional pattern, and using all frequencies of a frequency range simultaneously, is provided with first and second electrically conductive elements disposed coaxially relative to a central axis. The first element has a first surface of revolution about the axis, the first surface of revolution tapering radially outwardly while extending axially away from the second element to terminate at a first axial end of the first element. The second element has a second surface of revolution about the axis, the second surface of revolution tapering radially outwardly while extending axially toward the first element to terminatemore » at a first axial end of the second element. The first and second surfaces of revolution overlap one another radially and axially, and are mutually non-conformal.« less

  12. Tetrapod-like axial regionalization in an early ray-finned fish

    PubMed Central

    Sallan, Lauren Cole

    2012-01-01

    Tetrapods possess up to five morphologically distinct vertebral series: cervical, thoracic, lumbar, sacral and caudal. The evolution of axial regionalization has been linked to derived Hox expression patterns during development and the demands of weight-bearing and walking on land. These evolutionary and functional explanations are supported by an absence of similar traits in fishes, living and extinct. Here, I show that, Tarrasius problematicus, a marine ray-finned fish from the Mississippian (Early Carboniferous; 359–318 Ma) of Scotland, is the first non-tetrapod known to possess tetrapod-like axial regionalization. Tarrasius exhibits five vertebral regions, including a seven-vertebrae ‘cervical’ series and a reinforced ‘sacrum’ over the pelvic area. Most vertebrae possess processes for intervertebral contact similar to tetrapod zygapophyses. The fully aquatic Tarrasius evolved these morphologies alongside other traits convergent with early tetrapods, including a naked trunk, and a single median continuous fin. Regional modifications in Tarrasius probably facilitated pelagic swimming, rather than a terrestrial lifestyle or walking gait, presenting an alternative scenario for the evolution of such traits in tetrapods. Axial regionalization in Tarrasius could indicate tetrapod-like Hox expression patterns, possibly representing the primitive state for jawed vertebrates. Alternately, it could signal a weaker relationship, or even a complete disconnect, between Hox expression domains and vertebrate axial plans. PMID:22628471

  13. Mechanical Perturbations of the Walking Surface Reveal Unaltered Axial Trunk Stiffness in Chronic Low Back Pain Patients

    PubMed Central

    Meijer, Onno G.

    2016-01-01

    Introduction Patients with chronic low back pain (CLBP) often demonstrate altered timing of thorax rotations in the transverse plane during gait. Increased axial trunk stiffness has been claimed to cause this movement pattern. Objectives The objective of this study was to assess whether axial trunk stiffness is increased in gait in CLBP patients. Methods 15 CLBP patients and 15 healthy controls walked on a treadmill that imposed rotational perturbations in the transverse plane. The effect of these perturbations on transverse pelvis, thorax and trunk (thorax relative to pelvis) rotations was evaluated in terms of residual rotations, i.e., the deviation of these movements from the unperturbed patterns. In view of the heterogeneity of the CLBP group, we additionally performed a subgroup comparison between seven patients and seven controls with maximal between-group contrast for timing of thorax rotations. Results Rotations of the walking surface had a clear effect on transverse pelvis, thorax and trunk rotations in all groups. No significant between-group differences on residual transverse pelvis, thorax and trunk rotations were observed. Conclusion Axial trunk stiffness in gait does not appear to be increased in CLBP. Altered timing of thorax rotations in CLBP does not seem to be a result of increased axial trunk stiffness. PMID:27310528

  14. Clinical applications of perforator-based propeller flaps in upper limb soft tissue reconstruction.

    PubMed

    Ono, Shimpei; Sebastin, Sandeep J; Yazaki, Naoya; Hyakusoku, Hiko; Chung, Kevin C

    2011-05-01

    A propeller flap is an island flap that moves from one orientation to another by rotating around its vascular axis. The vascular axis is stationary, and flap movement is achieved by revolving on this axis. Early propeller flaps relied on a thick, subcutaneous pedicle to maintain vascularity, and this limited the flap rotation to 90°. With increasing awareness of the location and the vascular territory perfused by cutaneous perforators, it is now possible to design propeller flaps based on a single perforator, so-called "perforator-based propeller flaps." These flaps permit flap rotation up to 180°. We present the results of upper limb soft tissue reconstruction using perforator-based propeller flaps. We constructed a treatment strategy based on the location of the soft tissue defect and the perforator anatomy for expedient wound coverage in 1 stage. All perforator-based propeller flaps derived from 3 institutions that were used for upper limb soft tissue reconstruction were retrospectively analyzed. The parameters studied included the size and location of the defect, the perforator that was used, the size and shape of the flap, the direction (ie, clockwise or counter-clockwise) of flap rotation, the degree of twisting of the perforator, the management of the donor site (ie, linear closure or skin grafting), and flap survival (recorded as the percentage of the flap area that survived). Twelve perforator-based propeller flaps were used to reconstruct upper limb soft tissue defects in 12 patients. Six different perforators were used as vascular pedicles. The donor defects of 11 flaps could be closed primarily. One flap was partially lost in a patient with electrical burns. Perforator-based propeller flaps provide a reliable option for covering small- to medium-size upper limb soft tissue defects. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. [APPLICATION VALUE OF INDOCYANINE GREEN ANGIOGRAPHY IN FLAP RECONSTRUCTIVE SURGERY].

    PubMed

    Yang, Kai; Mu, Lan; Liu, Yan; Peng, Zhe; Li, Guangxue

    2015-09-01

    To investigate the utility of indocyanine green angiography in flap reconstructive surgery and possibility of decrease the complications. Indocyanine green angiography was performed on 14 patients undergoing flap reconstructive surgery between February and December 2014 to evaluate the blood perfusion of the flap and to adjust the operation plan. Of 14 cases, 2 were male and 12 were female, aged 23-58 years (mean, 35.5 years); 11 flaps were used for breast reconstruction [including 3 free deep inferior epigastric antery perforator (DIEP) flaps, 4 pedicled transverse rectus abdominis myocutaneous flaps (TRAM), 2 pedicled TRAM and free TRAM, and 2 pedicled latissimus dorsi myocutaneous flaps and prosthesis], 1 pedicled latissimus dorsi myocutaneous flap for repairing chest wall defect, 1 pedicled profunda artery perforator (PAP) flap for upper leg defect, and 1 pedicled descending genicular artery perforator flap for knee defect. The size of the flaps ranged from 9 cm x 6 cm to 26 cm x 12 cm. A total of 32 indocyanine green angiography were performed. There was no adverse reactions to the infusion of indocyanine green. The surgery management was adjusted according to results of indocyanine green angiography findings in 5 of 14 cases. The distal part of flap were discarded because of poor perfusion in 3 cases (1 DIEP flap, 1 TRAM, and 1 PAP flap) and the other 2 cases (pedicled TRAM) needed additional free anastomosis to ensure sufficient blood supply (pedicled TRAM and free TRAM); the other flaps were harvested according to preoperative plan and repaired defect successfully. The mean follow-up was 5 months (range, 1-9 months). The other flaps survived without infection or fat necrosis except 1 PAP flap with distal necrosis. Intraoperative indocyanine green angiography can provide real-time information of flap perfusion and then the operation plan can be adjusted in time to ensure the flap survival.

  16. PIV Measurements on a Blowing Flap

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V.; Stead, Daniel J.

    2004-01-01

    PIV measurements of the flow in the region of a flap side edge are presented for several blowing flap configurations. The test model is a NACA 63(sub 2)-215 Hicks Mod-B main-element airfoil with a half-span Fowler flap. Air is blown from small slots located along the flap side edge on either the top, bottom or side surfaces. The test set up is described and flow measurements for a baseline and three blowing flap configurations are presented. The effects that the flap tip jets have on the structure of the flap side edge flow are discussed for each of the flap configurations tested. The results indicate that blowing air from a slot located along the top surface of the flap greatly weakened the top vortex system and pushed it further off the top surface. Blowing from the bottom flap surface kept the strong side vortex further outboard while blowing from the side surface only strengthened the vortex system or accelerated the merging of the side vortex to the flap top surface. It is concluded that blowing from the top or bottom surfaces of the flap may lead to a reduction of flap side edge noise.

  17. Long-Term Patency of Twisted Vascular Pedicles in Perforator-Based Propeller Flaps.

    PubMed

    Jakubietz, Rafael G; Nickel, Aljoscha; Neshkova, Iva; Schmidt, Karsten; Gilbert, Fabian; Meffert, Rainer H; Jakubietz, Michael G

    2017-10-01

    Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps. In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap. The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss. The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.

  18. Plastic Surgery Challenges in War Wounded I: Flap-Based Extremity Reconstruction

    PubMed Central

    Sabino, Jennifer M.; Slater, Julia; Valerio, Ian L.

    2016-01-01

    Scope and Significance: Reconstruction of traumatic injuries requiring tissue transfer begins with aggressive resuscitation and stabilization. Systematic advances in acute casualty care at the point of injury have improved survival and allowed for increasingly complex treatment before definitive reconstruction at tertiary medical facilities outside the combat zone. As a result, the complexity of the limb salvage algorithm has increased over 14 years of combat activities in Iraq and Afghanistan. Problem: Severe poly-extremity trauma in combat casualties has led to a large number of extremity salvage cases. Advanced reconstructive techniques coupled with regenerative medicine applications have played a critical role in the restoration, recovery, and rehabilitation of functional limb salvage. Translational Relevance: The past 14 years of war trauma have increased our understanding of tissue transfer for extremity reconstruction in the treatment of combat casualties. Injury patterns, flap choice, and reconstruction timing are critical variables to consider for optimal outcomes. Clinical Relevance: Subacute reconstruction with specifically chosen flap tissue and donor site location based on individual injuries result in successful tissue transfer, even in critically injured patients. These considerations can be combined with regenerative therapies to optimize massive wound coverage and limb salvage form and function in previously active patients. Summary: Traditional soft tissue reconstruction is integral in the treatment of war extremity trauma. Pedicle and free flaps are a critically important part of the reconstructive ladder for salvaging extreme extremity injuries that are seen as a result of the current practice of war. PMID:27679751

  19. New model of flap-gliding flight.

    PubMed

    Sachs, Gottfried

    2015-07-21

    A new modelling approach is presented for describing flap-gliding flight in birds and the associated mechanical energy cost of travelling. The new approach is based on the difference in the drag characteristics between flapping and non-flapping due to the drag increase caused by flapping. Thus, the possibility of a gliding flight phase, as it exists in flap-gliding flight, yields a performance advantage resulting from the decrease in the drag when compared with continuous flapping flight. Introducing an appropriate non-dimensionalization for the mathematical relations describing flap-gliding flight, results and findings of generally valid nature are derived. It is shown that there is an energy saving of flap-gliding flight in the entire speed range compared to continuous flapping flight. The energy saving reaches the highest level in the lower speed region. The travelling speed of flap-gliding flight is composed of the weighted average of the differing speeds in the flapping and gliding phases. Furthermore, the maximum range performance achievable with flap-gliding flight and the associated optimal travelling speed are determined. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Intercostal artery perforator propeller flap for reconstruction of trunk defects following sarcoma resection.

    PubMed

    Zang, Mengqing; Yu, Shengji; Xu, Libin; Zhao, Zhenguo; Zhu, Shan; Ding, Qiang; Liu, Yuanbo

    2015-06-01

    Trunk defects following soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities and some trunk regions lack reliable recipient vessels. The intercostal arteries give off multiple perforators, which distribute widely over the trunk and can supply various pedicle flaps. Our purpose is to use various intercostal artery perforator propeller flaps for trunk oncologic reconstruction. Between November 2013 and July 2014, nine intercostal artery perforator propeller flaps were performed in seven patients to reconstruct the defects following sarcoma resection in different regions of the trunk, including the back, lumbar, chest, and abdomen. Two perforators from intercostal arteries were identified for each flap using Doppler ultrasound probe adjacent to the defect. The perforator with visible pulsation was chosen as the pedicle vessel. An elliptical flap was raised and rotated in a propeller fashion to repair the defects. There were one dorsal intercostal artery perforator flap, four dorsolateral intercostal artery perforator flaps, three lateral intercostal artery perforator flaps, and one anterior intercostal artery perforator flap. The mean skin paddle dimension was 9.38 cm in width (range 6-14 cm) and 21.22 cm in length (range 13-28 cm). All intercostal artery perforator flaps survived completely, except for marginal necrosis in one flap harvested close to the previous flap donor site. The intercostal artery perforator propeller flap provides various and valuable options in our reconstructive armamentarium for trunk oncologic reconstruction. To our knowledge, this is the first case series of using intercostal artery perforator propeller flaps for trunk oncologic reconstruction and clinical application of dorsolateral intercostal artery perforator flaps. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions.

    PubMed

    Hummelink, S; Verhulst, Arico C; Maal, Thomas J J; Hoogeveen, Yvonne L; Schultze Kool, Leo J; Ulrich, Dietmar J O

    2017-07-01

    Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available nowadays, we can combine information to preoperatively plan the optimal flap volume to be harvested. In this proof-of-concept, we investigated whether projection of a virtual flap planning onto the patient's abdomen using a projection method could result in harvesting the correct flap volume. In six patients (n = 9 breasts), 3D stereophotogrammetry and CTA data were combined from which a virtual flap planning was created comprising perforator locations, blood vessel trajectory and flap size. All projected perforators were verified with Doppler ultrasound. Intraoperative flap measurements were collected to validate the determined flap delineation volume. The measured breast volume using 3D stereophotogrammetry was 578 ± 127 cc; on CTA images, 527 ± 106 cc flap volumes were planned. The nine harvested flaps weighed 533 ± 109 g resulting in a planned versus harvested flap mean difference of 5 ± 27 g (flap density 1.0 g/ml). In 41 out of 42 projected perforator locations, a Doppler signal was audible. This proof-of-concept shows in small numbers that flap volumes can be included into a virtual DIEP flap planning, and transferring the virtual planning to the patient through a projection method results in harvesting approximately the same volume during surgery. In our opinion, this innovative approach is the first step in consequently achieving symmetric breast volumes in DIEP flap breast reconstructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Influence of Flap Thickness on Nipple Projection After Nipple Reconstruction Using a Modified Star Flap.

    PubMed

    Ishii, Naohiro; Ando, Jiro; Harao, Michiko; Takemae, Masaru; Kishi, Kazuo

    2018-05-07

    In nipple reconstruction, the width, length, and thickness of modified star flaps are concerns for long-term reconstructed nipple projection. However, the flap's projection has not been analyzed, based on its thickness. The aim of the present study was to investigate how flap thickness in a modified star flap influences the resulting reconstructed nipple and achieves an appropriate flap width in design. Sixty-three patients who underwent nipple reconstruction using a modified star flap following implant-based breast reconstruction between August 2014 and July 2016 were included in this case-controlled study. The length of laterally diverging flaps was 1.5 times their width. The thickness of each flap was measured using ultrasonography, and the average thickness was defined as the flap thickness. We investigated the correlation between the resulting reconstructed nipple and flap thickness, and the difference of the change in the reconstructed nipple projection after using a thin or thick flap. The average flap thickness was 3.8 ± 1.7 (range 2.5-6.0) mm. There was a significant, linear correlation between the flap thickness and resulting reconstructed nipple projection (β = 0.853, p < 0.01). Furthermore, the difference between the thin and thick flaps in the resulting reconstructed nipple projection was significant (p < 0.01). Measuring the flap thickness preoperatively may allow surgeons to achieve an appropriate flap width; otherwise, alternative methods for higher projection might be used. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  3. Medium- and Large-Sized Autologous Breast Reconstruction using a Fleur-de-lys Profunda Femoris Artery Perforator Flap Design: A Report Comparing Results with the Horizontal Profunda Femoris Artery Perforator Flap.

    PubMed

    Hunsinger, Vincent; Lhuaire, Martin; Haddad, Kevin; Wirz, Francesco-Saverio; Abedalthaqafi, Samah; Obadia, Déborah; Derder, Mohamed; Marchac, Alexandre; Benjoar, Marc David; Hivelin, Mikael; Lantieri, Laurent

    2018-06-02

     The volume of the profunda femoris artery perforator (PAP) flap limits its indications to small- and medium-sized breast reconstructions after modified radical mastectomy for cancer. We report a modified PAP flap design, including not only a vertical extension that increases its volume but also the skin surface, which suits larger breasts requiring immediate or delayed breast reconstructions and compare the results with our horizontal skin paddle PAP flap experience.  In our center between November 2014 and November 2016, 51 consecutive patients underwent a PAP flap breast reconstruction following breast cancer. A retrospective analysis on the collected data was performed to compare 34 patients with a bra cup smaller than C who underwent 41 horizontal PAP flap procedures, with those ( n  = 17) of a bra cup greater than or equal to C who underwent 21 fleur-de-lys PAP flap procedures. Demographic, anthropometric, flap and surgical characteristics, postoperative complication rates, and hospital stay were compared between the two groups.  The average flap weight was 480 g (range: 340-735 g) for the fleur-de-lys PAP flap group compared with 222 g (range: 187-325 g) for the horizontal PAP flap procedure ( p  < 0.001). The mean flap dimensions were 25 × 18 cm for the fleur-de-lys PAP flap group compared with 25 × 7 cm in the horizontal PAP flap group. No flap failure was observed in the fleur-de-lys PAP flap group compared with two flap failures secondary to venous thrombosis in the horizontal PAP flap group ( NS ). Three patients (14%) experienced delayed healing at the donor site compared with four patients (10%) in the horizontal PAP flap group ( NS ).  The fleur-de-lys skin paddle design not only allows an increase of the horizontal PAP flap volume, but also increases the skin surface, with an acceptable donor site morbidity. For medium- or large-sized breasts, the fleur-de-lys PAP flap seems to be ideal when a DIEP flap-based reconstruction is contraindicated. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Axial mesendoderm refines rostrocaudal pattern in the chick nervous system.

    PubMed

    Rowan, A M; Stern, C D; Storey, K G

    1999-07-01

    There has long been controversy concerning the role of the axial mesoderm in the induction and rostrocaudal patterning of the vertebrate nervous system. Here we investigate the neural inducing and regionalising properties of defined rostrocaudal regions of head process/prospective notochord in the chick embryo by juxtaposing these tissues with extraembryonic epiblast or neural plate explants. We localise neural inducing signals to the emerging head process and using a large panel of region-specific neural markers, show that different rostrocaudal levels of the head process derived from headfold stage embryos can induce discrete regions of the central nervous system. However, we also find that rostral and caudal head process do not induce expression of any of these molecular markers in explants of the neural plate. During normal development the head process emerges beneath previously induced neural plate, which we show has already acquired some rostrocaudal character. Our findings therefore indicate that discrete regions of axial mesendoderm at headfold stages are not normally responsible for the establishment of rostrocaudal pattern in the neural plate. Strikingly however, we do find that caudal head process inhibits expression of rostral genes in neural plate explants. These findings indicate that despite the ability to induce specific rostrocaudal regions of the CNS de novo, signals provided by the discrete regions of axial mesendoderm do not appear to establish regional differences, but rather refine the rostrocaudal character of overlying neuroepithelium.

  5. Free-style dual plane recycling tensor fascia lata musculocutaneous perforator flap for reconstruction of recurrent trochanteric defects.

    PubMed

    Han, Ba Leun; Choi, Hwan Jun

    2014-03-01

    Sequential flap coverage might be required for recurrent defects, but reusing a flap as a donor site has seldom been reported. The concept of a "free-style flap" has been developed, and it allows reconstructive surgeons to raise flaps with various designs reliably, even at sites of previous flap surgery. This article presents the concept of free-style recycling of a tensor fascia lata flap into a perforator-based flap separated in 2 planes in a patient with a recurrent bilateral trochanteric defect. If a reliable perforator is preserved and identified within the tissues by computed tomography angiography or a Doppler device, a new perforator flap can be designed and raised at the previous flap site.

  6. Swimming performance and unique wake topology of the sea hare (Aplysia)

    NASA Astrophysics Data System (ADS)

    Zhou, Zhuoyu; Mittal, Rajat

    2018-03-01

    The Aplysia, commonly referred to as the "sea hare," is a marine mollusc that swims using large-amplitude flapping of its wide, winglike parapodia. In this study, flow simulations with a relatively simple kinematical model are used to gain insights into the vortex dynamics, thrust generation, and energetics of locomotion for this animal. A unique vortex pattern characterized by three distinct trains of vortex ringlike structures is observed in the wake of this animal. These vortex rings are associated with a positive momentum flux in the wake that counteracts the drag generated by the body. Simulations indicate propulsive efficiencies of up to 24% and terminal swimming speeds of about 0.9 body length per cycle. Swimming speeds are found to increase with increasing parapodial flapping amplitude as well as wavelength of undulation.

  7. Foucher first dorsal metacarpal artery flap versus littler heterodigital neurovascular flap in resurfacing thumb pulp loss defects.

    PubMed

    Delikonstantinou, Iraklis P; Gravvanis, Andreas I; Dimitriou, Vasilios; Zogogiannis, Ioannis; Douma, Amalia; Tsoutsos, Dimosthenis A

    2011-08-01

    Our study aims to illustrate the advantages and disadvantages of Foucher's first dorsal metacarpal artery flap and Littler's heterodigital neurovascular flap in thumb pulp reconstruction, by assessing wound healing of donor and recipient sites, sensibility, and functional outcome of the reconstructed thumb. Fourteen male patients were reconstructed either with Foucher (n = 8) or Littler flap (n = 6). Dissection of Foucher's flap was faster than that of Littler's flap. All Littler flaps survived completely, but we experienced 1 partial Foucher flap necrosis. Thumb motility and stability was optimal in all patients. Wound healing of donor sites was achieved in both groups. Two patients reconstructed with Littler flap developed scar contractures and presented a reduced range of motion of donor finger and first webspace, respectively. Although Littler flap resulted in better sensibility and tactile gnosis of the reconstructed thumb-pulp, Foucher flap ensured negligible donor site morbidity, complete cortical reorientation, and better overall hand function.

  8. Wind-Tunnel Investigation of an NACA 23021 Airfoil with a 0.32-Airfoil-Chord Double Slotted Flap

    NASA Technical Reports Server (NTRS)

    Fischel, Jack; Riebe, John M

    1944-01-01

    An investigation was made in the LMAL 7- by 10-foot wind tunnel of a NACA 23021 airfoil with a double slotted flap having a chord 32 percent of the airfoil chord (0.32c) to determine the aerodynamic section characteristics with the flaps deflected at various positions. The effects of moving the fore flap and rear flap as a unit and of deflecting or removing the lower lip of the slot were also determined. Three positions were selected for the fore flap and at each position the maximum lift of the airfoil was obtained with the rear flap at the maximum deflection used at that fore-flap position. The section lift of the airfoil increased as the fore flap was extended and maximum lift was obtained with the fore flap deflected 30 deg in the most extended position. This arrangement provided a maximum section lift coefficient of 3.31, which was higher than the value obtained with either a 0.2566c or a 0.40c single-slotted-flap arrangement and 0.25 less than the value obtained with a 0.4c double-slotted-flap arrangement on the same airfoil. The values of the profile-drag coefficient obtained with the 0.32c double slotted flap were larger than those for the 0.2566c or 0.40c single slotted flaps for section lift coefficients between 1.0 and approximately 2.7. At all values of the section lift coefficient above 1.0, the 0.40c double slotted flap had a lower profile drag than the 0.32c double slotted flap. At various values of the maximum section lift coefficient produced by various flap defections, the 0.32c double slotted flap gave negative section pitching-moment coefficients that were higher than those of other slotted flaps on the same airfoil. The 0.32c double slotted flap gave approximately the same maximum section lift coefficient as, but higher profile-drag coefficients over the entire lift range than, a similar arrangement of a 0.30c double slotted flap on an NACA 23012 airfoil.

  9. The Economy in Autologous Tissue Transfer: Part 1. The Kiss Flap Technique.

    PubMed

    Zhang, Yi Xin; Hayakawa, Thomas J; Levin, L Scott; Hallock, Geoffrey G; Lazzeri, Davide

    2016-03-01

    All reconstructive microsurgeons realize the need to improve aesthetic and functional donor-site outcomes. A "kiss" flap design concept was developed to increase the surface area of skin flap coverage while minimizing donor-site morbidity. The main goal of the kiss flap technique is to harvest multiple skin paddles that are smaller than those raised with traditional techniques, to minimize donor-site morbidity. These smaller flap components are then sutured to each other, or said to kiss each other side-by-side, to create a large, wide flap. The skin paddles in the kiss technique can be linked to one another by a variety of native intrinsic vascular connections, by additional microanastomosis, or both. This technique can be widely applied to both free and pedicle flaps, and essentially allows for the reconstruction of a large defect while providing the easy primary closure of a smaller donor-site defect. According to their origin of blood supply, kiss flaps are classified into three styles and five types. All of the different types of kiss flaps are unique in both flap design and harvest technique. Most kiss flaps are based on common flaps already familiar to the reconstructive surgeon. The basis of the kiss flap design concept is to convert multiple narrow flaps into a single unified flap of the desired greater width. This maximizes the size of the resulting flap and minimizes donor-site morbidity, as a direct linear closure is usually possible. Therapeutic, V.

  10. The Temporalis Muscle Flap for Palate Reconstruction: Case Series and Review of the Literature

    PubMed Central

    Brennan, Tara; Tham, Tristan M.; Costantino, Peter

    2017-01-01

    Introduction  The temporalis myofascial (TM) is an important reconstructive flap in palate reconstruction. Past studies have shown the temporalis myofascial flap to be safe as well as effective. Free flap reconstruction of palate defects is also a popular method used by contemporary surgeons. We aim to reaffirm the temporalis myofascial flap as a viable alternative to free flaps for palate reconstruction. Objective  We report our results using the temporalis flap for palate reconstruction in one of the largest case series reported. Our literature review is the first to describe complication rates of palate reconstruction using the TM flap. Methods  Retrospective chart review and review of the literature. Results  Fifteen patients underwent palate reconstruction with the TM flap. There were no cases of facial nerve injury. Five (33%) of these patients underwent secondary cranioplasty to address temporal hollowing after the TM flap. Three out of fifteen (20%) had flap related complications. Fourteen (93%) of the palate defects were successfully reconstructed, with the remaining case pending a secondary procedure to close the defect. Ultimately, all of the flaps (100%) survived. Conclusion  The TM flap is a viable method of palate defect closure with a high defect closure rate and flap survival rate. TM flaps are versatile in repairing palate defects of all sizes, in all regions of the palate. Cosmetic deformity created from TM flap harvest may be addressed using cranioplasty implant placement, either primarily or during a second stage procedure. PMID:28680495

  11. Improved wound healing of postischemic cutaneous flaps with the use of bone marrow-derived stem cells.

    PubMed

    Hu, Melissa; Ludlow, David; Alexander, J Steven; McLarty, Jerry; Lian, Timothy

    2014-03-01

    To determine if the intravascular delivery of mesenchymal stem cells improves wound healing and blood perfusion to postischemic cutaneous flap tissues. Randomized controlled study. A murine model of a cutaneous flap was created based on the inferior epigastric vessels. Mice (n = 14) underwent 3.5 hours of ischemia followed by reperfusion. Bone marrow stromal cells (BMSCs) 1 × 10(6) were injected intravenously. Wound healing was then assessed measuring percent flap necrosis, flap perfusion, and tensile strength of the flap after a period of 14 days. Localization of BMSCs was determined with radiolabeled and fluorescent labeled BMSCs. Postischemic cutaneous flap tissues treated with BMSCs demonstrated significantly less necrosis than control flaps (P <0.01). Beginning on postoperative day 5, BMSC-treated flaps demonstrated greater blood perfusion than untreated flaps (P <0.01). Tensile strength of BMSC-treated cutaneous flaps was significantly higher (P <0.01), with a mean strength of 283.4 ± 28.4 N/m than control flaps with a mean of 122.4 ± 23.5 N/m. Radiolabeled BMSCs localized to postischemic flaps compared to untreated tissues (P = 0.001). Fluorescent microscopy revealed incorporation of BMSCs into endothelial and epithelial tissues of postischemic flaps. This study demonstrates that the intravascular delivery of BMSCs increases wound healing and promotes flap survival following ischemia-reperfusion injury of cutaneous tissue flaps. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  12. [A variant of island flaps for the covering of pressure sores: the hatchet flap. Apropos of 31 cases].

    PubMed

    Quillot, M; Lodde, J P; Pegorier, O; Reynaud, J P; Cormerais, A

    1994-08-01

    The authors propose a modification of the classical design of island flaps for cover of pressure sores, applied to gluteus maximus and tensor fascia lata muscles: the hatchet flap. 31 flaps have been used including 13 gluteus maximus superior flaps for sacral pressure sores, 9 gluteal inferior flaps for ischial pressure sores and 9 tensor fascia lata flaps for trochanteric pressure sores. A small partial necrosis and two cases of sepsis were observed in this series, but did not require surgical revision. The authors emphasize the value of this modification of the classical flap design, which preserves an even better musculocutaneous capital in these patients, who are often already multi-operated. The very rapid recovery of patients supports the authors' application of hatchet flaps to the surgery of pressure sores, and suggests the extension to other musculocutaneous flaps in the future.

  13. Why Do Kestrels Soar?

    PubMed Central

    Hernández-Pliego, Jesús; Rodríguez, Carlos; Bustamante, Javier

    2015-01-01

    Individuals allocate considerable amounts of energy to movement, which ultimately affects their ability to survive and reproduce. Birds fly by flapping their wings, which is dependent on the chemical energy produced by muscle work, or use soaring-gliding flight, in which chemical energy is replaced with energy harvested from moving air masses, such as thermals. Flapping flight requires more energy than soaring-gliding flight, and this difference in the use of energy increases with body mass. However, soaring-gliding results in lower speeds than flapping, especially for small species. Birds therefore face a trade-off between energy and time costs when deciding which flight strategy to use. Raptors are a group of large birds that typically soar. As relatively light weight raptors, falcons can either soar on weak thermals or fly by flapping with low energy costs. In this paper, we study the flight behavior of the insectivorous lesser kestrel (Falco naumanni) during foraging trips and the influence of solar radiation, which we have adopted as a proxy for thermal formation, on kestrel flight variables. We tracked 35 individuals from two colonies using high frequency GPS-dataloggers over four consecutive breeding seasons. Contrary to expectations, kestrels relied heavily on thermal soaring when foraging, especially during periods of high solar radiation. This produced a circadian pattern in the kestrel flight strategy that led to a spatial segregation of foraging areas. Kestrels flapped towards foraging areas close to the colony when thermals were not available. However, as soon as thermals were formed, they soared on them towards foraging areas far from the colony, especially when they were surrounded by poor foraging habitats. This reduced the chick provisioning rate at the colony. Given that lesser kestrels have a preference for feeding on large insects, and considering the average distance they cover to capture them during foraging trips, to commute using flapping flight would result in a negative energy balance for the family group. Our results show that lesser kestrels prioritize saving energy when foraging, suggesting that kestrels are more energy than time-constrained during the breeding season. PMID:26689780

  14. The Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study.

    PubMed

    Panse, Nikhil S; Joshi, Sheetal B; Sahasrabudhe, Parag B; Bahetee, B; Gurude, Pradnya; Chandanwale, Ajay

    2017-05-01

    Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Recently, perforator propeller flaps have been used for resurfacing the upper extremity. The anterior interosseus artery perforator flap is an uncommonly used and described flap. This study was divided into anatomical study and clinical application in a IV level of evidence. In the anatomical study, five upper extremities were studied. Clinically, 12 patients underwent reconstruction using the anterior interosseus artery perforator flap. Flaps were performed by a single surgeon. A retrospective review of these cases from November 2008 to May 2014 is presented. The anterior interosseus artery perforator was identified in four out of five cadaver limbs. The septocutaneous perforator was in the fifth extensor compartment around 4 cm proximal to the wrist joint. Of the twelve flaps, there was complete necrosis in one flap, and partial necrosis in one flap. The patient with complete necrosis underwent skin grafting at a later date. The wound healed secondarily in case of partial flap necrosis. Anterior interosseus artery perforator flap must be considered as an important reconstructive option in the armamentarium of the plastic surgeon, while managing hand and wrist defects.

  15. [Aesthetic effect of wound repair with flaps].

    PubMed

    Tan, Qian; Zhou, Hong-Reng; Wang, Shu-Qin; Zheng, Dong-Feng; Xu, Peng; Wu, Jie; Ge, Hua-Qiang; Lin, Yue; Yan, Xin

    2012-08-01

    To investigate the aesthetic effect of wound repair with flaps. One thousand nine hundred and ninety-six patients with 2082 wounds hospitalized from January 2004 to December 2011. These wounds included 503 deep burn wounds, 268 pressure sores, 392 soft tissue defects caused by trauma, 479 soft tissue defects due to resection of skin cancer and mole removal, 314 soft tissue defects caused by scar excision, and 126 other wounds. Wound area ranged from 1.5 cm x 1.0 cm to 30.0 cm x 22.0 cm. Sliding flaps, expanded flaps, pedicle flaps, and free flaps were used to repair the wounds in accordance with the principle and timing of wound repair with flaps. Five flaps showed venous congestion within 48 hours post-operation, 2 flaps of them improved after local massage. One flap survived after local heparin wet packing and venous bloodletting. One flap survived after emergency surgical embolectomy and bridging with saphenous vein graft. One flap showed partial necrosis and healed after skin grafting. The other flaps survived well. One thousand three hundred and twenty-one patients were followed up for 3 months to 2 years, and flaps of them were satisfactory in shape, color, and elasticity, similar to that of normal skin. Some patients underwent scar revision later with good results. Application of suitable flaps in wound repair will result in quick wound healing, good function recovery, and satisfactory aesthetic effect.

  16. Foot strike pattern differently affects the axial and transverse components of shock acceleration and attenuation in downhill trail running.

    PubMed

    Giandolini, Marlene; Horvais, Nicolas; Rossi, Jérémy; Millet, Guillaume Y; Samozino, Pierre; Morin, Jean-Benoît

    2016-06-14

    Trail runners are exposed to a high number of shocks, including high-intensity shocks on downhill sections leading to greater risk of osseous overuse injury. The type of foot strike pattern (FSP) is known to influence impact severity and lower-limb kinematics. Our purpose was to investigate the influence of FSP on axial and transverse components of shock acceleration and attenuation during an intense downhill trail run (DTR). Twenty-three trail runners performed a 6.5-km DTR (1264m of negative elevation change) as fast as possible. Four tri-axial accelerometers were attached to the heel, metatarsals, tibia and sacrum. Accelerations were continuously recorded at 1344Hz and analyzed over six sections (~400 steps per subject). Heel and metatarsal accelerations were used to identify the FSP. Axial, transverse and resultant peak accelerations, median frequencies and shock attenuation within the impact-related frequency range (12-20Hz) were assessed between tibia and sacrum. Multiple linear regressions showed that anterior (i.e. forefoot) FSPs were associated with higher peak axial acceleration and median frequency at the tibia, lower transverse median frequencies at the tibia and sacrum, and lower transverse peak acceleration at the sacrum. For resultant acceleration, higher tibial median frequency but lower sacral peak acceleration were reported with forefoot striking. FSP therefore differently affects the components of impact shock acceleration. Although a forefoot strike reduces impact severity and impact frequency content along the transverse axis, a rearfoot strike decreases them in the axial direction. Globally, the attenuation of axial and resultant impact-related vibrations was improved using anterior FSPs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. [Predictability of the corneal flap creation with the femtosecond laser in LASIK].

    PubMed

    Mai, Zhi-bin; Liu, Su-bing; Nie, Xiao-li; Sun, Hong-xia; Xin, Bao-li; Tang, Xiu-xia

    2012-05-01

    To observe the predictability of corneal flap creation with the FEMTO LDV femtosecond laser and analyze preliminarily the factors correlating to the thickness and diameter of the flap . It was a study of serial cases. 260 eyes of 130 consecutive patients were treated with the FEMTO LDV. The eyes were assigned to two groups according to intended flap thickness, 110 µm (208 eyes) and 90 µm (52 eyes). Intended flap diameter varied from 8.5 to 9.5 mm. Difference analysis of flap diameter and intended diameter as well as flap thickness and intended thickness were made. The data was analyzed with SPSS to sum up a multiple stepwise regression formula that could express their quantitative relationship. The 90 µm flap group had a average flap thickness of (95.12 ± 7.65) µm, while for the 110 µm group the average flap thickness was (104.81 ± 3.09) µm. The difference between right and left eyes was not statistically significant (t(110 µm) = -1.223, t(90 µm) = -1.343, P > 0.05). Corneal flap thickness was inversely correlated with flap diameter (r(110 µm) = -0.143, r(90 µm) = -0.315, P < 0.05), but was not related to preoperative patient age, corneal thickness, keratometric value K or intraocular pressure (r(110 µm) = -0.160, 0.054, -0.011, -0.363; r(90 µm) = 0.024, 0.074, -0.212, -0.434, all P > 0.05). Corneal flap diameter was positively correlated with preoperative corneal keratometric value K and thickness (P < 0.001, P < 0.05). Multiple stepwise regression analysis showed flap diameter was an influencing factor for flap thickness. Preoperative corneal keratometric value K and thickness were influencing factors for flap diameter. The LASIK flap creation with the FEMTO LDV laser has relatively good predictability. Flap diameter is an influencing factor for flap thickness.

  18. Forelimb kinematics and motor patterns of swimming loggerhead sea turtles (Caretta caretta): are motor patterns conserved in the evolution of new locomotor strategies?

    PubMed

    Rivera, Angela R V; Wyneken, Jeanette; Blob, Richard W

    2011-10-01

    Novel functions in animals may evolve through changes in morphology, muscle activity or a combination of both. The idea that new functions or behavior can arise solely through changes in structure, without concurrent changes in the patterns of muscle activity that control movement of those structures, has been formalized as the neuromotor conservation hypothesis. In vertebrate locomotor systems, evidence for neuromotor conservation is found across evolutionary transitions in the behavior of terrestrial species, and in evolutionary transitions from terrestrial species to flying species. However, evolutionary transitions in the locomotion of aquatic species have received little comparable study to determine whether changes in morphology and muscle function were coordinated through the evolution of new locomotor behavior. To evaluate the potential for neuromotor conservation in an ancient aquatic system, we quantified forelimb kinematics and muscle activity during swimming in the loggerhead sea turtle, Caretta caretta. Loggerhead forelimbs are hypertrophied into wing-like flippers that produce thrust via dorsoventral forelimb flapping. We compared kinematic and motor patterns from loggerheads with previous data from the red-eared slider, Trachemys scripta, a generalized freshwater species exhibiting unspecialized forelimb morphology and anteroposterior rowing motions during swimming. For some forelimb muscles, comparisons between C. caretta and T. scripta support neuromotor conservation; for example, the coracobrachialis and the latissimus dorsi show similar activation patterns. However, other muscles (deltoideus, pectoralis and triceps) do not show neuromotor conservation; for example, the deltoideus changes dramatically from a limb protractor/elevator in sliders to a joint stabilizer in loggerheads. Thus, during the evolution of flapping in sea turtles, drastic restructuring of the forelimb was accompanied by both conservation and evolutionary novelty in limb motor patterns.

  19. Wind-Tunnel Investigation of a Rectangular NACA 2212 Airfoil with Semispan Ailerons and with Nonperforated, Balanced Double Split Flaps for Use as Aerodynamic Brakes

    NASA Technical Reports Server (NTRS)

    Ivey, Margaret F

    1945-01-01

    Flat-plate flaps with no wing cutouts and flaps having Clark Y sections with corresponding cutouts made in wing were tested for various flap deflections, chord-wise locations, and gaps between flaps and airfoil contour. The drag was slightly lower for wing with airfoil section flaps. Satisfactory aileron effectiveness was obtained with flap gap of 20% wing chord and flap-nose location of 80 percent wing chord behind leading edge. Airflow was smooth and buffeting negligible.

  20. [Pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasoseptal perforation].

    PubMed

    Yin, Xinghong; Hu, Wei; Zhang, Xinhai; Sun, Min

    2014-10-01

    To explore curative effect with pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap to repair nasal septal perforation. Dissecting mucoperichondrium and mucoperioseptum around the perforation and taking dowm and out xia-ward to the floor of nasal cavity to make a inferior extremity pedicle flap. Then,the flap was tumbled and sutured onto raw surface of contralateral side through perforation. Reapplicating autoallergic temporal musculofascial flap to repair another side perforation. Repairing perforation Sin twelve cases were sucessfully healed in endoscope. The pedicle flap of nasal septum-basis nasi and temporal muscucofascial flap is easy to acquire and no rejection. The flap has good blood supplying, high survival rate and provides adequate transplantating materail to repair comparatively large perforation.

  1. [The repair of bulky tissue defect of forearm with skin flaps].

    PubMed

    Huang, Xiaoyuan; Long, Jianhong; Xie, Tinghong; Zhang, Minghua; Zhang, Pihong; Yang, Xinghua; Zhong, Keqin

    2002-12-01

    To evaluate the repairing methods of bulky tissue defect of forearm with flaps. Twenty-one burned patients with wounds in the forearm were enrolled in this study. The injury causes were high-voltage electricity, hot press or crush injury. After local debridement, the forearm defects were repaired with pedicled complex flaps, latissimus dorsi musculocutaneous island flaps or large thoraco-abdominal flaps immediately. All the flaps survived very well with satisfactory results except for 1 patient in whom local ischemic necrosis and sub-flap infection at the distal end of the flap occurred. Early debridement followed by skin flaps with pedicles or musculocutaneous flaps transfer could be simple, safe and reliable treatment strategies in the management of bulky tissue defects of the forearm due to burn, electric injury, or other devastating injuries.

  2. The perforator pedicled propeller (PPP) flap method: report of two cases.

    PubMed

    Hyakusoku, Hiko; Ogawa, Rei; Oki, Koichiro; Ishii, Nobuaki

    2007-10-01

    Perforator flaps are thin free-tissue transfers consisting of skin and subcutaneous tissue which have the advantage of decreasing donor site morbidity. We have reconstructed postburn scar contractures using "propeller flaps" of the remaining healthy skin around the recipient sites. In this paper, we report on two cases and describe the concept of using "perforator flaps" and "propeller flaps" together as what are called "perforator pedicled propeller (PPP) flaps." Patient 1 was an 18-year-old man with a sacral pressure ulcer. The soft tissue defect was reconstructed with a rotated superior gluteal artery PPP flap. Patient 2 was a 53-year-old woman who presented with an open fracture of the right elbow. The skin defect over the fracture was covered with a rotated deep brachial artery PPP flap raised on the lateral upper arm. The PPP flaps are useful for burn reconstruction and repairing various types of wound. Moreover, microsurgery is unnecessary. The PPP flap may be classified into two types: the central axis type and the acentric axis type. The central axis PPP flap is significant when used as a 90-degree-rotation island flap, and the acentric axis PPP flap is significant when used as a 180-degree-rotation island flap. Both types are easy to harvest and useful for repairing various kinds of wound.

  3. Implication for using heme methyl hyperfine shifts as indicators of heme seating as related to stereoselectivity in the catabolism of heme by heme oxygenase: in-plane heme versus axial his rotation.

    PubMed

    Ogura, Hiroshi; Evans, John P; de Montellano, Paul R Ortiz; La Mar, Gerd N

    2008-01-08

    The triple mutant of the solubilized, 265-residue construct of human heme oxygenase, K18E/E29K/R183E-hHO, has been shown to redirect the exclusive alpha-regioselectivity of wild-type hHO to primarily beta,delta-selectivity in the cleavage of heme (Wang, J., Evans, J. P., Ogura, H., La Mar, G. N., and Ortiz de Montellano, P. R. (2006) Biochemistry 45, 61-73). The 1H NMR hyperfine shift pattern for the substrate and axial His CbetaH's and the substrate-protein contacts of the cyanide-inhibited protohemin and 2,4-dimethyldeuterohemin complexes of the triple mutant have been analyzed in detail and compared to data for the WT complex. It is shown that protein contacts for the major solution isomers for both substrates in the mutant dictate approximately 90 degrees in-plane clockwise rotation relative to that in the WT. The conventional interpretation of the pattern of substrate methyl hyperfine shifts, however, indicates substrate rotations of only approximately 50 degrees . This paradox is resolved by demonstrating that the axial His25 imidazole ring also rotates counterclockwise with respect to the protein matrix in the mutant relative to that in the WT. The axial His25 CbetaH hyperfine shifts are shown to serve as independent probes of the imidazole plane orientation relative to the protein matrix. The analysis indicates that the pattern of heme methyl hyperfine shifts cannot be used alone to determine the in-plane orientation of the substrate as it relates to the stereospecificity of heme cleavage, without explicit consideration of the orientation of the axial His imidazole plane relative to the protein matrix.

  4. Reconstruction of the Foot and Ankle Using Pedicled or Free Flaps: Perioperative Flap Survival Analysis

    PubMed Central

    Li, Xiucun; Cui, Jianli; Maharjan, Suraj; Lu, Laijin; Gong, Xu

    2016-01-01

    Objective The purpose of this study is to determine the correlation between non-technical risk factors and the perioperative flap survival rate and to evaluate the choice of skin flap for the reconstruction of foot and ankle. Methods This was a clinical retrospective study. Nine variables were identified. The Kaplan-Meier method coupled with a log-rank test and a Cox regression model was used to predict the risk factors that influence the perioperative flap survival rate. The relationship between postoperative wound infection and risk factors was also analyzed using a logistic regression model. Results The overall flap survival rate was 85.42%. The necrosis rates of free flaps and pedicled flaps were 5.26% and 20.69%, respectively. According to the Cox regression model, flap type (hazard ratio [HR] = 2.592; 95% confidence interval [CI] (1.606, 4.184); P < 0.001) and postoperative wound infection (HR = 0.266; 95% CI (0.134, 0.529); P < 0.001) were found to be statistically significant risk factors associated with flap necrosis. Based on the logistic regression model, preoperative wound bed inflammation (odds ratio [OR] = 11.371,95% CI (3.117, 41.478), P < 0.001) was a statistically significant risk factor for postoperative wound infection. Conclusion Flap type and postoperative wound infection were both independent risk factors influencing the flap survival rate in the foot and ankle. However, postoperative wound infection was a risk factor for the pedicled flap but not for the free flap. Microvascular anastomosis is a major cause of free flap necrosis. To reconstruct complex or wide soft tissue defects of the foot or ankle, free flaps are safer and more reliable than pedicled flaps and should thus be the primary choice. PMID:27930679

  5. Supraclavicular artery perforator flap in management of post-burn neck reconstruction: clinical experience

    PubMed Central

    Ismail, H.; Elshobaky, A.

    2016-01-01

    Summary Anterior cervical contractures of the neck represent a great challenge for plastic and reconstructive surgeons. Necks can be reconstructed with a wide range of surgical techniques, including chimeric flaps, supercharged flap, pre-expanded flaps, “superthin” flaps and perforator flaps. The supraclavicular flap is easy to harvest without the need for free tissue transfer. It provides a relatively large flap for neck resurfacing with tissue very similar to that of the neck. Between January 2013 and March 2015, 20 patients suffering from postburn neck contracture underwent reconstruction with 20 unilateral supraclavicular artery perforator flaps. Nineteen patients had post-burn neck contractures (9 cases type Іc, 10 cases type Пc) while only one had post-burn granulation tissue in the neck. We harvested fifteen flaps from the right side and five from the left. Size of the reconstructed defect ranged from 23x10 to14x6, and flap size varied from 25/11 to 16/7cm. Period of follow up ranged from 27-2months (average 12.3). Nineteen flaps survived well (95% survival rate): only one was lost due to iatrogenic extensive dissection over the pedicle. Five cases showed distal superficial epidermolysis, and 2 cases showed 2 cm complete distal necrosis. All patients were managed conservatively. Our results coincide with other literature results confirming the efficacy and rich vascularity of this flap. In all cases with distal partial necrosis, flaps were 23 cm or more. We recommend that supraclavicular flaps of more than 22 cm in length are not harvested immediately and that flaps are expanded before harvesting. Expanding the supraclavicular flap increases its surface area and decreases donor site morbidity. PMID:28149252

  6. Full-scale-wind-tunnel Tests of a 35 Degree Sweptback Wing Airplane with High-velocity Blowing over the Training-edge Flaps

    NASA Technical Reports Server (NTRS)

    Kelley, Mark W; Tolhurst, William H JR

    1955-01-01

    A wind-tunnel investigation was made to determine the effects of ejecting high-velocity air near the leading edge of plain trailing-edge flaps on a 35 degree sweptback wing. The tests were made with flap deflections from 45 degrees to 85 degrees and with pressure ratios across the flap nozzles from sub-critical up to 2.9. A limited study of the effects of nozzle location and configuration on the efficiency of the flap was made. Measurements of the lift, drag, and pitching moment were made for Reynolds numbers from 5.8 to 10.1x10(6). Measurements were also made of the weight rate of flow, pressure, and temperature of the air supplied to the flap nozzles.The results show that blowing on the deflected flap produced large flap lift increments. The amount of air required to prevent flow separation on the flap was significantly less than that estimated from published two-dimensional data. When the amount of air ejected over the flap was just sufficient to prevent flow separation, the lift increment obtained agreed well with linear inviscid fluid theory up to flap deflections of 60 degrees. The flap lift increment at 85 degrees flap deflection was about 80 percent of that predicted theoretically.With larger amounts of air blown over the flap, these lift increments could be significantly increased. It was found that the performance of the flap was relatively insensitive to the location of the flap nozzle, to spacers in the nozzle, and to flow disturbances such as those caused by leading-edge slats or discontinuities on the wing or flap surfaces. Analysis of the results indicated that installation of this system on an F-86 airplane is feasible.

  7. Evolution in Monitoring of Free Flap Autologous Breast Reconstruction after Nipple-Sparing Mastectomy: Is There a Best Way?

    PubMed

    Frey, Jordan D; Stranix, John T; Chiodo, Michael V; Alperovich, Michael; Ahn, Christina Y; Allen, Robert J; Choi, Mihye; Karp, Nolan S; Levine, Jamie P

    2018-05-01

    Free flap monitoring in autologous reconstruction after nipple-sparing mastectomy remains controversial. The authors therefore examined outcomes in nipple-sparing mastectomy with buried free flap reconstruction versus free flap reconstruction incorporating a monitoring skin paddle. Autologous free flap reconstructions with nipple-sparing mastectomy performed from 2006 to 2015 were identified. Demographics and operative results were analyzed and compared between buried flaps and those with a skin paddle for monitoring. Two hundred twenty-one free flaps for nipple-sparing mastectomy reconstruction were identified: 50 buried flaps and 171 flaps incorporating a skin paddle. The most common flaps used were deep inferior epigastric perforator (64 percent), profunda artery perforator (12.1 percent), and muscle-sparing transverse rectus abdominis myocutaneous flaps (10.4 percent). Patients undergoing autologous reconstructions with a skin paddle had a significantly greater body mass index (p = 0.006). Mastectomy weight (p = 0.017) and flap weight (p < 0.0001) were significantly greater in flaps incorporating a skin paddle. Comparing outcomes, there were no significant differences in flap failure (2.0 percent versus 2.3 percent; p = 1.000) or percentage of flaps requiring return to the operating room (6.0 percent versus 4.7 percent; p = 0.715) between groups. Buried flaps had an absolute greater mean number of revision procedures per nipple-sparing mastectomy (0.82) compared with the skin paddle group (0.44); however, rates of revision procedures per nipple-sparing mastectomy were statistically equivalent between the groups (p = 0.296). Although buried free flap reconstruction in nipple-sparing mastectomy has been shown to be safe and effective, the authors' technique has evolved to favor incorporating a skin paddle, which allows for clinical monitoring and can be removed at the time of secondary revision. Therapeutic, III.

  8. Refining the cross-finger flap: Considerations of flap insetting, aesthetics and donor site morbidity.

    PubMed

    Chong, Chew-Wei; Lin, Cheng-Hung; Lin, Yu-Te; Hsu, Chung-Chen; Chen, Shih-Heng

    2018-04-01

    We described a laterally based cross-finger flap for reconstruction of soft tissue defects in the fingers. This modification enables coverage of volar or dorsal soft tissue defects at the distal, middle or proximal phalanx. From March 2015 to January 2017, a total of 12 patients (13 fingers) underwent soft tissue reconstruction of the fingers with a laterally based cross-finger flap. The flap dimensions ranged from 13 ×7 mm to 43 ×13 mm. Eleven of the 13 flaps survived completely. The two flap failures were attributed to injuries in the donor fingers, rendering the blood supply of the flaps unreliable. All donor sites were closed primarily without the need for skin grafting, negating the problem of donor site morbidity that is associated with skin graft harvesting. The laterally based cross-finger flap is a versatile flap with less donor site morbidity and better aesthetics than a conventional cross-finger flap. We described the design of the flap, as well as the advantages and disadvantages, in doing a laterally based cross-finger flap. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Influence of the narrow {111} planes on axial and planar ion channeling.

    PubMed

    Motapothula, M; Dang, Z Y; Venkatesan, T; Breese, M B H; Rana, M A; Osman, A

    2012-05-11

    We report channeling patterns where clearly resolved effects of the narrow {111} planes are observed in axial and planar alignments for 2 MeV protons passing through a 55 nm [001] silicon membrane. At certain axes, such as <213> and <314>, the offset in atomic rows forming the narrow {111} planes results in shielding from the large potential at the wide {111} planes, producing a region of shallow, asymmetric potential from which axial channeling patterns have no plane of symmetry. At small tilts from such axes, different behavior is observed from the wide and narrow {111} planes. At planar alignment, distinctive channeling effects due to the narrow planes are observed. As a consequence of the shallow potential well at the narrow planes, incident protons suffer dechanneled trajectories which are excluded from channeling within the wide planes, resulting in an anomalously large scattered beam at {111} alignment.

  10. Free versus perforator-pedicled propeller flaps in lower extremity reconstruction: What is the safest coverage? A meta-analysis.

    PubMed

    Bekara, Farid; Herlin, Christian; Somda, Serge; de Runz, Antoine; Grolleau, Jean Louis; Chaput, Benoit

    2018-01-01

    Currently, increasingly reconstructive surgeon consider the failure rates of perforator propeller flaps especially in the distal third of the lower leg are too important and prefer to return to the use of free flap at first line option with failure rates frequently lower than 5%. So, we performed a systematic review with meta-analysis comparing free flaps (perforator-based or not) and pedicled-propeller flaps to respond to the question "what is the safest coverage for distal third of the lower limb?" This review was conducted according to PRISMA criteria. From 1991 to 2015, MEDLINE®, Pubmed central, Embase and Cochrane Library were searched. The pooled estimations were performed by meta-analysis. The homogeneity Q statistic and the I 2 index were computed. We included 36 articles for free flaps (1,226 flaps) and 19 articles for pedicled-propeller flaps (302 flaps). The overall failure rate was 3.9% [95%CI:2.6-5.3] for free flaps and 2.77% [95%CI:0.0-5.6] for pedicled-propeller flaps (P = 0.36). The complication rates were 19.0% for free flaps and 21.4% for pedicled-propeller flaps (P = 0.37). In more detail, we noted for free flaps versus pedicled-propeller flaps: partial necrosis (2.70 vs. 6.88%, P = 0.001%), wound dehiscence (2.38 vs. 0.26%, P = 0.018), infection (4.45 vs. 1.22%, P = 0.009). The coverage failure rate was 5.24% [95%CI:3.68-6.81] versus 2.99% [95%CI:0.38-5.60] without significant difference (P = 0.016). In the lower limb the complications are not rare and many teams consider the free flaps to be safer. In this meta-analysis we provide evidence that failure and overall complications rate of perforator propeller flaps are comparable with free flaps. Although, partial necrosis is significantly higher for pedicled-propeller flaps than free flaps, in reality the success of coverage appears similar. © 2016 Wiley Periodicals, Inc. Microsurgery, 38:109-119, 2018. © 2016 Wiley Periodicals, Inc.

  11. Electrical burns of the abdomen.

    PubMed

    Srivastava, Rakesh Kumar; Kumar, Ritesh

    2013-09-01

    A 35-year-old male farmer came in contact with 11,000 volts high tension electric wire and sustained full thickness burn wounds over scapula, upper limb and anterior abdominal wall along with perforation of the intestine. Patient was initially managed conservatively in general surgery ward and was referred to us after 3 days with necrosis of the burned skin and muscles over the shoulder and abdomen. Patient was initially managed conservatively and then thorough debridement of the necrotic skin over the left shoulder and upper arm was done and the area was split skin grafted. Patient developed enterocutaneous fistula, which healed over a period of 8 weeks. The granulating wound over the abdomen was also skin grafted and patient was discharged after 18 days. About 4 months, after the discharge patient presented with ventral hernia. Repair of ventral hernia by synthetic mesh application and reconstruction of the abdominal wall with a free tensor fascia lata flap was done over the mesh, but the flap failed. Then after debridement two random pattern transposition skin flaps, one from the right upper and another from the left lower abdomen were transposed over the abdominal wound and donor area was skin grafted. Patient was discharged after 17 days.

  12. Investigation of Full-Scale Split Trailing-Edge Wing Flaps with Various Chords and Hinge Locations

    NASA Technical Reports Server (NTRS)

    Wallace, Rudolf

    1936-01-01

    This report gives the results of an investigation conducted in the NACA full-scale wind tunnel on a small parasol monoplane equipped with three different split trailing-edge wing flaps. The object of the investigation was to determine and correlate data on the characteristics of the airplane and flaps as affected by variation in flap chord, flap deflection, and flap location along the wing chord. The results give the lift, the drag, and the pitching moment characteristics of the airplane, and the flap forces and moments, the pressure distribution over the flaps and wing at one section, and the downwash characteristics of the flap and wing combinations.

  13. Surgical therapy of vulvar cancer: how to choose the correct reconstruction?

    PubMed Central

    2016-01-01

    Objective To create a comprehensive algorithmic approach to reconstruction after vulvar cancer ablative surgery, which includes both traditional and perforator flaps, evaluating anatomical subunits and shape of the defect. Methods We retrospectively reviewed 80 cases of reconstruction after vulvar cancer ablative surgery, performed between June 2006 and January 2016, transferring 101 flaps. We registered the possibility to achieve the complete wound closure, even in presence of very complex defects, and the postoperative complications. On the basis of these experience, analyzing the choices made and considering the complications, we developed an algorithm to help with the selection of the flap in vulvoperineal reconstruction after oncologic ablative surgery for vulvar cancer. Results We employed eight types of different flaps, including 54 traditional fasciocutaneous V-Y flaps, 23 rectus abdominis myocutaneous flaps, 11 anterolateral thigh flaps, three V-Y gracilis myocutaneous flaps, three free style perforators V-Y flaps from the inner thigh, two Limberg flaps, two lotus flaps, two deep inferior epigastric artery perforator flap, and one superficial circumflex iliac artery perforator flap. The structures most frequently involved in resection were vulva, perineum, mons pubis, groins, vagina, urethra and, more rarely, rectum, bladder, and lower abdominal wall. Conclusion The algorithm we implemented can be a useful tool to help flap selection. The key points in the decision-making process are: anatomical subunits to be covered, overall shape and symmetry of the defect and some patient features such as skin laxity or previous radiotherapy. Perforator flaps, when feasible, must be considered standard in vulvoperineal reconstruction, although in some cases traditional flaps remain the best choice. PMID:27550406

  14. Reconstruction of Complex Facial Defects Using Cervical Expanded Flap Prefabricated by Temporoparietal Fascia Flap.

    PubMed

    Zhang, Ling; Yang, Qinghua; Jiang, Haiyue; Liu, Ge; Huang, Wanlu; Dong, Weiwei

    2015-09-01

    Reconstruction of complex facial defects using cervical expanded flap prefabricated by temporoparietal fascia flap. Complex facial defects are required to restore not only function but also aesthetic appearance, so it is vital challenge for plastic surgeons. Skin grafts and traditional flap transfer cannot meet the reconstructive requirements of color and texture with recipient. The purpose of this sturdy is to create an expanded prefabricated temporoparietal fascia flap to repair complex facial defects. Two patients suffered severe burns on the face underwent complex facial resurfacing with prefabricated cervical flap. The vasculature of prefabricated flap, including the superficial temporal vessel and surrounding fascia, was used as the vascular carrier. The temporoparietal fascia flap was sutured underneath the cervical subcutaneous tissue, and expansion was begun in postoperative 1 week. After 4 to 6 months of expansion, the expander was removed, facial scars were excised, and cervical prefabricated flap was elevated and transferred to repair the complex facial defects. Two complex facial defects were repaired successfully by prefabricated temporoparietal fascia flap, and prefabricated flaps survived completely. On account of donor site's skin was thinner and expanded too fast, 1 expanded skin flap was rupture during expansion, but necrosis was not occurred after the 2nd operation. Venous congestion was observed in 1 patient, but after dressing, flap necrosis was not happened. Donor site was closed primarily. Postoperative follow-up 6 months, the color, texture of prefabricated flap was well-matched with facial skin. This method of expanded prefabricated flap may provide a reliable solution to the complex facial resurfacing.

  15. Reconstruction of Large Postburn Facial-Scalp Scars by Expanded Pedicled Deltopectoral Flap and Random Scalp Flap: Technique Improvements to Enlarge the Reconstructive Territory.

    PubMed

    Ma, Xianjie; Li, Yang; Li, Weiyang; Liu, Chaohua; Peng, Pai; Song, Baoqiang; Xia, Wensen; Yi, Chenggang; Lu, Kaihua; Su, Yingjun

    2017-09-01

    The scars of face and scalp caused by burning often show as 1 large facial-scalp scar. The deltopectoral flap was recognized as one of the first choices for the facial scar reconstruction. However, this flap cannot cross the level of zygomatic arch traditionally when it was transferred with pedicle. When the flap reconstructed the facial-scalp scars with expanded random scalp flap, another flap was often needed to reconstruct the remaining temple and forehead scars. The authors reviewed 24 patients of large facial-scalp scars reconstructed by expanded pedicled deltopectoral flap and scalp flap with several technique improvements. The seaming scar between the deltopectoral flap and scalp flap in the temple region formed the new hairline. The technique improvements included ligation of the perforating branches of the transverse cervical artery and thoracoacromial artery when dissecting the pocket, the partial bolster compressive dressing to the distal part of the flap and dividing the pedicle partly as a delaying procedure before dividing the pedicle completely. Good skin compliance, normal contours, and emotional expression were noted. There were complications including expander exposure in 3 patients, stretch marks in 5 patients, flap tip necrosis in 2 patients, and mild postoperative hypertrophic scars in 3 patients. In conclusion, the expanded pedicled deltopectoral flap can enlarge the reconstructive territory in face successfully with the technique improvements. The combination of the expanded pedicled deltopectoral flap and scalp flap is a reliable and excellent reconstructive option for large postburn facial-scalp scars.

  16. Free style perforator based propeller flaps: Simple solutions for upper extremity reconstruction!

    PubMed

    Panse, Nikhil; Sahasrabudhe, Parag

    2014-01-01

    The introduction of perforator flaps by Koshima et al. was met with much animosity in the plastic surgery fraternity. The safety concerns of these flaps following the intentional twist of the perforators have prevented widespread adoption of this technique. Use of perforator based propeller flaps in the lower extremity is gradually on the rise, but their use in upper extremity reconstruction is infrequently reported, especially in the Indian subcontinent. We present a retrospective series of 63 free style perforator flaps used for soft tissue reconstruction of the upper extremity from November 2008 to June 2013. Flaps were performed by a single surgeon for various locations and indications over the upper extremity. Patient demographics, surgical indication, defect features, complications and clinical outcome are evaluated and presented as an uncontrolled case series. 63 free style perforator based propeller flaps were used for soft tissue reconstruction of 62 patients for the upper extremity from November 2008 to June 2013. Of the 63 flaps, 31 flaps were performed for trauma, 30 for post burn sequel, and two for post snake bite defects. We encountered flap necrosis in 8 flaps, of which there was complete necrosis in 4 flaps, and partial necrosis in four flaps. Of these 8 flaps, 7 needed a secondary procedure, and one healed secondarily. Although we had a failure rate of 12-13%, most of our failures were in the early part of the series indicative of a learning curve associated with the flap. Free style perforator based propeller flaps are a reliable option for coverage of small to moderate sized defects. Therapeutic IV.

  17. Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.

    PubMed

    Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng

    2015-07-01

    Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.

  18. Improving Pressure Ulcer Reconstruction: Our Protocol and the COP (Cone of Pressure) Flap

    PubMed Central

    Edstrom, Lee; Szymanski, Karen; Schmidt, Scott; Bevivino, Jack; Zienowicz, Richard; Stark, Jennifer; Taylor, Helena O.; Podda, Silvio; Liu, Paul

    2017-01-01

    Background: Surgical treatment of pressure ulcers is challenging for high recurrence rates. Deepithelialized flaps have been used previously with the aim to eliminate shearing forces and the cone of pressure (COP) effect. The goal of this study is to adopt a standardized protocol and evaluate if 2 different flap techniques affect outcomes. Methods: The novel COP flap is illustrated. Twenty patients were prospectively treated with flap coverage over a 36-month period. According to the flap type, patients were assigned to 2 groups: group 1 with 11 patients treated with the COP flap and group 2 with 9 patients treated with conventional flap without anchoring technique. We adopted a standardized protocol of debridement, tissue cultures, and negative-pressure wound therapy. Rotation fasciocutaneous flaps were used for both groups and mean follow-up was 19 months. The COP flap is a large deepithelialized rotation flap inset with transcutaneous nonabsorbable bolster sutures. The 2 groups were comparable for demographics and ulcer location and size (P < 0.05). Five patients showed positive cultures and were treated with antibiotics and negative-pressure therapy before surgery. Results: Recurrence rates were 12% in the COP flap group and 60% in the conventional flap coverage group (P < 0.001). Results were compared at 16-month follow-up. Conclusions: The COP flap significantly reduces recurrences and eliminates shearing forces, suture ripping, and tension on superficial soft-tissue layers. The technique can be applied to both ischial and sacral pressure sores. The flap provides padding over bony prominence without jeopardizing flap vascularity. PMID:28458961

  19. Propeller thoracodorsal artery perforator flap for breast reconstruction.

    PubMed

    Angrigiani, Claudio; Rancati, Alberto; Escudero, Ezequiel; Artero, Guillermo; Gercovich, Gustavo; Deza, Ernesto Gil

    2014-08-01

    The thoracodorsal artery perforator (TDAP) flap has been described for breast reconstruction. This flap requires intramuscular dissection of the pedicle. A modification of the conventional TDAP surgical technique for breast reconstruction is described, utilizing instead a propeller TDAP flap. The authors present their clinical experience with the propeller TDAP flap in breast reconstruction alone or in combination with expanders or permanent implants. From January 2009 to February 2013, sixteen patients had breast reconstruction utilizing a propeller TDAP flap. Retrospective analysis of patient characteristics, clinical indications, procedure and outcomes were performed. The follow-up period ranged from 4 to 48 months. Sixteen patients had breast reconstruction using a TDAP flap with or without simultaneous insertion of an expander or implant. All flaps survived, while two cases required minimal resection due to distal flap necrosis, healing by second intention. There were not donor-site seromas, while minimal wound dehiscence was detected in two cases. The propeller TDAP flap appears to be safe and effective for breast reconstruction, resulting in minimal donor site morbidity. The use of this propeller flap emerges as a true alternative to the traditional TDAP flap.

  20. The Anterior Interosseus Artery Perforator Flap: Anatomical Dissections and Clinical Study

    PubMed Central

    Panse, Nikhil S; Joshi, Sheetal B; Sahasrabudhe, Parag B; Bahetee, B; Gurude, Pradnya; Chandanwale, Ajay

    2017-01-01

    BACKGROUND Reconstruction of upper extremity deformities continues to be a challenge to the reconstructive surgeon. Various loco regional, distant and free flaps are available for reconstruction. However, each has its own set of advantages and disadvantages. Of the commonly performed local flaps, radial artery forearm flap, and the posterior interosseus artery flap stand out prominently. Recently, perforator propeller flaps have been used for resurfacing the upper extremity. The anterior interosseus artery perforator flap is an uncommonly used and described flap. METHODS This study was divided into anatomical study and clinical application in a IV level of evidence. In the anatomical study, five upper extremities were studied. Clinically, 12 patients underwent reconstruction using the anterior interosseus artery perforator flap. Flaps were performed by a single surgeon. A retrospective review of these cases from November 2008 to May 2014 is presented. RESULTS The anterior interosseus artery perforator was identified in four out of five cadaver limbs. The septocutaneous perforator was in the fifth extensor compartment around 4 cm proximal to the wrist joint. Of the twelve flaps, there was complete necrosis in one flap, and partial necrosis in one flap. The patient with complete necrosis underwent skin grafting at a later date. The wound healed secondarily in case of partial flap necrosis. CONCLUSION Anterior interosseus artery perforator flap must be considered as an important reconstructive option in the armamentarium of the plastic surgeon, while managing hand and wrist defects. PMID:28713704

  1. Facial artery musculomucosal flap for reconstruction of skull base defects: a cadaveric study.

    PubMed

    Xie, Liyue; Lavigne, François; Rahal, Akram; Moubayed, Sami Pierre; Ayad, Tareck

    2013-08-01

    Failure in skull base defects reconstruction following tumor resection can have serious consequences such as ascending meningitis and pneumocephaly. The nasoseptal flap showed a very low incidence of cerebrospinal fluid leak but is not always available. The superiorly pedicled facial artery musculomucosal (FAMM) flap has been successfully used for reconstruction of head and neck defects. Our objective is to show that the FAMM flap can be used as a new alternative in skull base reconstruction. Cadaveric study. Feasibility. Thirteen specimens underwent bilateral FAMM flap dissection. Two new modifications of the traditional FAMM flap have been developed. Feasibility in FAMM flap transfer to the skull base was investigated through endoscopic skull base dissection and maxillectomy in four specimens. Measurements were recorded for each harvested flap. The mean surface area of the modified FAMM flap efficient for reconstruction was 15.90 cm(2) . The flaps easily covered the simulated defects of the frontal sinus and the fovea ethmoidalis areas. Modifications of the traditional FAMM flap were necessary for a tension-free coverage of the planum sphenoidale and sella turcica. The FAMM flap holds high potential as a new alternative vascular flap in skull base reconstruction. However, it has not been used in patients yet and should be considered only when other options are not available. New modifications developed in this article can elongate the traditional FAMM flap, potentially contributing to a tighter seal of the skull base defect than FAMM flap alone. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Reconstruction of Anterolateral Thigh Defects Using Perforator-Based Propeller Flaps.

    PubMed

    Iida, Takuya; Yoshimatsu, Hidehiko; Koshima, Isao

    2017-10-01

    Usually, anterolateral thigh (ALT) defects with width more than 8 cm cannot be closed directly. Although several methods of using local flaps exist, flap mobility of these methods is limited. We introduced a perforator-based propeller flap for such reconstruction. Their maximal mobility, which minimizes their size, is their greatest advantage. In addition, we present our technical refinements including double-axes propeller flap, the use of indocyanine green real-time angiography, and supercharged propeller flap for safer flap transfer. Seven patients underwent perforator-based propeller flap reconstruction of ALT defects. Flaps were designed cranial or caudal to the defect according to the perforator locations. To maximize mobility, flaps were designed so that the perforator was located at the periphery and closer to the defect. After rotating the flap to the defect, indocyanine green angiography was performed to determine the need for supercharge. In all cases, all flaps survived completely. Defect size ranged from 12 × 11 cm to 18 × 16 cm, and flap size ranged from 7 × 5 cm to 15 × 7 cm. The number of perforators in the flap was 1 in 3 cases and 2 in 4 cases. Supercharging was performed in 3 cases. Donor-site complications, including gait disturbance, were not observed. This method achieves ALT defect closure with minimal donor-site morbidity and can provide prompt and aesthetically acceptable results. Indocyanine green real-time angiography and supercharging technique are also useful for safer and reliable flap transfer.

  3. Comparison of Dorsal Intercostal Artery Perforator Propeller Flaps and Bilateral Rotation Flaps in Reconstruction of Myelomeningocele Defects.

    PubMed

    Tenekeci, Goktekin; Basterzi, Yavuz; Unal, Sakir; Sari, Alper; Demir, Yavuz; Bagdatoglu, Celal; Tasdelen, Bahar

    2018-04-09

    Bilateral rotation flaps are considered the workhorse flaps in reconstruction of myelomeningocele defects. Since the introduction of perforator flaps in the field of reconstructive surgery, perforator flaps have been used increasingly in the reconstruction of various soft tissue defects all over the body because of their appreciated advantages. The aim of this study was to compare the complications and surgical outcomes between bilateral rotation flaps and dorsal intercostal artery perforator (DICAP) flaps in the soft tissue reconstruction of myelomeningocele defects. Between January 2005-February 2017, we studied 47 patients who underwent reconstruction of myelomeningocele defects. Patient demographics, operative data, and postoperative data were reviewed retrospectively and are included in the study. We found no statistically significant differences in patient demographics and surgical complications between these two groups; this may be due to small sample size. With regard to complications-partial flap necrosis, cerebrospinal fluid (CSF) leakage, necessity for reoperation, and wound infection-DICAP propeller flaps were clinically superior to rotation flaps. Partial flap necrosis was associated with CSF leakage and wound infection, and CSF leakage was associated with wound dehiscence. Although surgical outcomes obtained with DICAP propeller flaps were clinically superior to those obtained with rotation flaps, there was no statistically significant difference between the two patient groups. A well-designed comparative study with adequate sample size is needed. Nonetheless, we suggest using DICAP propeller flaps for reconstruction of large myelomeningocele defects.

  4. Indocyanine green laser angiography improves deep inferior epigastric perforator flap outcomes following abdominal suction lipectomy.

    PubMed

    Casey, William J; Connolly, Katharine A; Nanda, Alisha; Rebecca, Alanna M; Perdikis, Galen; Smith, Anthony A

    2015-03-01

    The reliability of deep inferior epigastric artery perforator (DIEP) flap reconstruction following abdominal liposuction is controversial. The authors' early cases were technically successful; however, they experienced high partial flap loss and fat necrosis rates. The authors sought to compare DIEP flap outcomes in the setting of prior liposuction after the use of intraoperative indocyanine green angiography compared to when flaps were assessed on clinical grounds alone. A retrospective review of a consecutive series of DIEP flaps following liposuction at a single institution was performed, comparing those evaluated on clinical grounds alone and those in which indocyanine green angiography was used intraoperatively. Outcomes measured included anastomotic complications, total flap loss, partial flap loss, fat necrosis, and postoperative abdominal wounds. Thirteen DIEP flaps following prior liposuction were performed on 11 patients from July of 2003 through January of 2014. All patients had preoperative imaging with duplex ultrasound or computed tomographic angiography to analyze perforator suitability before surgical exploration. Seven flaps were evaluated intraoperatively on clinical grounds alone. Six flaps were assessed and modified based on indocyanine green angiography. All flaps were successful; however, partial flap loss and fat necrosis rates dropped from 71.4 percent to 0 percent when indocyanine green angiography was used intraoperatively (p = 0.02). Indocyanine green angiography is an excellent vascular imaging modality for intraoperative use to assess flap perfusion, and improves outcomes in DIEP flaps when harvested after prior abdominal suction lipectomy.

  5. The changing role of pectoralis major flap in head and neck reconstruction.

    PubMed

    Liu, Hin-Lun; Chan, Jimmy Yu-Wai; Wei, William Ignace

    2010-11-01

    Although pectoralis major flap (PM flap) has been used as the workhorse flap in head and neck reconstruction, its use in head and neck defects seems to fall out of favour in the era of free tissue transfer. The aim of this review is to find out the role of PM flap in modern head and neck surgery. Medical records of patients who underwent PM flap reconstruction for head and neck defect in our division were reviewed. The age, gender, flap type, indication and complication rate were described. Between January 1998 and December 2008, 202 PM flaps were used for head and neck reconstruction in 192 patients. In the early study period (1998-June 2003), out of the 119 PM flap reconstructions, 106 (89%) were performed for immediate reconstruction after resection of head and neck tumour, while 10 (8%) were performed as salvage procedures for complication after tumour resection e.g. failure of free flap, pharyngocutaneous fistula. In the late study period (July 2003-2008), out of the 83 PM flap reconstructions, 58 (70%) were performed for immediate reconstruction, while 24 (29%) were performed as salvage procedures. For immediate reconstruction after tumour extirpation, 51 flaps (48%) were performed for reconstruction of the tongue in the early study period, while only 14 (24%) were performed in the late study period. The number of PM flap used for immediate reconstruction for other head and neck defects remained relatively static throughout the two study periods. Over the study period, there were 10 (5%) cases of partial flap necrosis and 2 (1%) total flap loss, making the overall flap necrosis rate 6%. In the era of free tissue transfer, the role of PM flap in head and neck surgery has shifted from immediate reconstruction to salvage operation. However, PM flap still has an unique role in the repair of certain head and neck defects.

  6. Tensor fascia lata flap versus tensor fascia lata perforator-based island flap for the coverage of extensive trochanteric pressure sores.

    PubMed

    Kim, Youn Hwan; Kim, Sang Wha; Kim, Jeong Tae; Kim, Chang Yeon

    2013-06-01

    Tensor fascia lata (TFL) musculocutaneous flaps often require a donor site graft when harvesting a large flap. However, a major drawback is that it also sacrifices the muscle. To overcome this disadvantage, we designed a TFL perforator-based island flap that was harvested from a site near the defect and involved transposition within 90 degrees without full isolation of the pedicles. We performed procedures on 17 musculocutaneous flaps and 23 perforator-based island flaps, and compared the outcomes of these surgeries. The overall complication rate was 27.5% (11 regions). There were 7 complications related to the musculocutaneous flaps and 4 complications related to the perforator flaps. Although there were no statistical differences between those groups, lower complication rates were associated with procedures involving perforator flaps. The TFL perforator procedure is a simple and fast operation that avoids sacrificing muscle. This decreases complication rates compared to true perforator flap techniques that require dissection around the perforator or pedicle.

  7. Propeller Flap for Complex Distal Leg Reconstruction: A Versatile Alternative when Reverse Sural Artery Flap is Not Feasible.

    PubMed

    Ademola, Samuel A; Michael, Afieharo I; Oladeji, Femi J; Mbaya, Kefas M; Oyewole, O

    2015-01-01

    Reverse sural artery fasciocutaneous flap has become a workhorse for the reconstruction of distal leg soft tissue defects. When its use is not feasible, perforator-based propeller flap offers a better, easier, faster, and cheaper alternative to free flap. We present our experience with two men both aged 34 years who sustained Gustilo 3B injuries from gunshot. The donor area for reversed sural artery flap was involved in the injuries. They had early debridement, external fixation, and wound coverage with perforator-based propeller flaps. The donor sites were covered with skin graft. All flaps survived. There were minor wound edge ulcers due to the pressure of positioning that did not affect flap survival and the ulcers healed with conservative management. Perforator-based propeller flap is a versatile armamentarium for reconstruction of soft tissue defects of the distal leg in resource-constrained settings, especially when the donor area for a reverse flow sural flap artery is involved in the injury.

  8. Analysis of HLA-B15 and HLA-B27 in spondyloarthritis with peripheral and axial clinical patterns.

    PubMed

    Londono, John; Santos, Ana Maria; Peña, Paola; Calvo, Enrique; Espinosa, Luis R; Reveille, John D; Vargas-Alarcon, Gilberto; Jaramillo, Carlos A; Valle-Oñate, Rafael; Avila, Mabel; Romero, Consuelo; Medina, Juan F

    2015-11-11

    Human leucocyte antigen (HLA) B27 and HLA-B15 are associated with spondyloarthritis (SpA). Recent Assessment of SpondyloArthritis international Society (ASAS) criteria emphasise a distinction between SpA with axial and peripheral patterns. We analysed whether HLA-A, HLA-B and HLA-DRB1 alleles could associate with these patterns. We studied 100 healthy individuals and 178 patients with SpA according to European Spondyloarthropathy Study Group (ESSG) criteria. Patients were then classified according to ASAS criteria, the axial spondyloarthritis pattern (axSpA) being defined by ascertained sacroiliitis and the peripheral pattern (pSpA) by enthesitis and/or arthritis in extremities. A combined ax/p pattern was also considered. Only HLA-B27 and HLA-B15 alleles were associated with SpA. ASAS criteria for axSpA were met in 152 patients (12 with isolated axSpA and 140 with a combined ax/p patterns). When the ASAS peripheral criteria were applied, 161 patients met these criteria (13 with isolated pSpA and 148 with a combined ax/p pattern). HLA-B27 was found in 83% of patients with axSpA and 43% of ax/pSpA patients according to axASAS. HLA-B27 occurred in 7% controls but not in any patient with isolated pSpA. HLA-B15 was encountered in 31% of patients with isolated pSpA and 20% of ax/pSpA patients according to pASAS criteria. Moreover, 2 healthy controls, but none of our patients with isolated axSpA were positive for HLA-B15. Our data suggest that the presence of HLA-B15 favours the development of isolated/combined peripheral rather than isolated axSpA, while HLA-B27 promotes an isolated/combined axial disease and excludes a peripheral pattern. HLA-B15 should be considered in addition to HLA-B27 when diagnosing patients with SpA according to ASAS criteria. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Piloted simulation study of two tilt-wing flap control concepts, phase 2

    NASA Technical Reports Server (NTRS)

    Birckelbaw, Lourdes G.; Corliss, Lloyd D.; Hindson, William S.; Churchill, Gary B.

    1994-01-01

    A two phase piloted simulation study has been conducted in the Ames Vertical Motion Simulator to investigate alternative wing and flap controls for tilt-wing aircraft. This report documents the flying qualities results and findings of the second phase of the piloted simulation study and describes the simulated tilt-wing aircraft, the flap control concepts, the experiment design and the evaluation tasks. The initial phase of the study compared the flying qualities of both a conventional programmed flap and an innovative geared flap. The second phase of the study introduced an alternate method of pilot control for the geared flap and further studied the flying qualities of the programmed flap and two geared flap configurations. In general, the pilot ratings showed little variation between the programmed flap and the geared flap control concepts. Some differences between the two control concepts were noticed and are discussed in this report. The geared flap configurations had very similar results. Although the geared flap concept has the potential to reduce or eliminate the pitch control power requirements from a tail rotor or a tail thruster at low speeds and in hover, the results did not show reduced tail thruster pitch control power usage with the geared flap configurations compared to the programmed flap configuration. The addition of pitch attitude stabilization in the second phase of simulation study greatly enhanced the aircraft flying qualities compared to the first phase.

  10. Free flap reconstruction for diabetic foot limb salvage.

    PubMed

    Sato, Tomoya; Yana, Yuichiro; Ichioka, Shigeru

    2017-12-01

    Although free flap is gaining popularity for the reconstruction of diabetic foot ulcers, it is unclear whether free flap reconstruction increases the chances of postoperative independent ambulation. The aim of this study is to evaluate the relationship between free flap success and postoperative ambulation. This study reviewed 23 cases of free flap reconstruction for diabetic foot ulcers between January 2007 and March 2014. Free rectus abdominis, latissimus dorsi, and anterolateral thigh flaps were used in ten, eight, and five patients, respectively. A comparison was made between free flap success and postoperative independent ambulation using Fisher's exact test. Two patients developed congestive heart failure with fatal consequences within 14 days postoperatively, resulting in an in-hospital mortality rate of 8.7%. Five patients lost their flaps (21.7%). Of the 16 patients who had flap success, 12 achieved independent ambulation. Five patients with flap loss did not achieve independent ambulation, except one patient who underwent secondary flap reconstruction using a distally based sural flap. Fisher's exact test revealed that independent ambulation was associated with free flap success (p = 0.047). The present study indicates that free flap reconstruction may increase the possibility of independent ambulation for patients with extensive tissue defects due to diabetic ulcers. Intermediate limb salvage rates and independent ambulation rates were favourable in patients with successful reconstruction. The use of foot orthoses and a team approach with pedorthists were effective to prevent recurrence.

  11. Pedicled Temporalis Muscle Flap for Craniofacial Reconstruction: A 35-Year Clinical Experience with 366 Flaps.

    PubMed

    Spanio di Spilimbergo, Stefano; Nordera, Paolo; Mardini, Samir; Castiglione, Giusy; Chim, Harvey; Pinna, Vittore; Brunello, Massimo; Cusino, Claudio; Roberto, Squaquara; Baciliero, Ugo

    2017-02-01

    In the past 130 years, the temporalis muscle flap has been used for a variety of different indications. In this age of microsurgery and perforator flaps, the temporalis muscle flap still has many useful applications for craniofacial reconstruction. Three hundred sixty-six temporalis muscle flaps were performed in a single center between 1978 and 2012. The authors divided the cases into two series-before and after 1994-because, after 1994, they started to perform free flap reconstructions, and indications for reconstruction with a temporalis muscle flap were changed RESULTS:: In the series after 1994, flaps were most commonly used for reconstruction of defects in the maxilla, mandible, and oropharynx, in addition to facial reanimation and filling of orbital defects. Complications included total flap necrosis (1.6 percent) and partial flap necrosis (10.7 percent). The rate of material extrusion at the donor site decreased after porous polyethylene was uniformly used for reconstruction from 17.1 to 7.9 percent. The pedicled temporalis muscle flap continues to have many applications in craniofacial reconstruction. With increasing use of free flaps, the authors' indications for the pedicled temporalis muscle flap are now restricted to (1) orbital filling for congenital or acquired anophthalmia; (2) filling of unilateral maxillectomy defects; and (3) facial reanimation in selected cases of facial nerve palsy. Therapeutic, IV.

  12. The versatile use of revisited de-epithelialization concept in superficial circumflex iliac and anterolateral thigh perforator free flap for head and neck reconstructions.

    PubMed

    Choi, Jong Woo; Kim, Young Chul; Oh, Tae Suk; Koh, Kyung S; Jeong, Woo Shik

    2017-06-01

    Although the perforator free flap is now a standard choice for head and neck reconstruction, problems such as microvascular complications, insufficient volume support for the defect, and fistula formation occur. We revisited a de-epithelialized concept for superficial circumflex iliac artery and anterolateral thigh perforator free flap to overcome these problems. We applied the de-epithelized perforator free flaps in 35 cases among 761 microsurgical head and neck reconstructions and investigated flap characteristics (length gain of pedicle, flap size, and volumetric analysis) and outcomes (flap failure, partial flap necrosis, hematoma, infection, and fistula). Satisfactory results were achieved regarding flap survival, volumetric compensation, and fistula formation. Flaps were transferred successfully in all patients, although 1 patient underwent revisional operation due to venous congestion. Transferred flap volume was significantly higher than the resected tumor volume (p < 0.01), which suggests volume augmentation in the destroyed neck envelope and a protective role against adjuvant radiation. Minor dehiscence and bleeding were seen in two cases, and no other complications were identified. The de-epithelialization concept for perforator free flap is helpful to overcome obstacles related to traditional free flaps in terms of flap survival and volumetric augmentation in head and neck reconstructions. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Free-style free flaps.

    PubMed

    Wei, Fu-Chan; Mardini, Samir

    2004-09-15

    Free-tissue transfer has become the accepted standard for reconstruction of complex defects. With the growth of this field, anatomic studies and clinical work have added many flaps to the armamentarium of the microvascular surgeon. Further advancements and experience with techniques of perforator flap surgery have allowed for the harvest of flaps in a free-style manner, where a flap is harvested based only on the preoperative knowledge of Doppler signals present in a specific region. Between June of 2002 and September of 2003, 13 free-style free flaps were harvested from the region of the thigh. All patients presented with an oral or pharyngeal cancer and underwent resection and immediate reconstruction of these flaps. All flaps were cutaneous and were harvested in a suprafascial plane. The average size of the flaps was 108 cm2 (range, 36 to 187 cm2), and the average length of the vascular pedicle was 10 cm (range, 9 to 12 cm). All flaps were successful in achieving wound coverage and functional outcomes without any vascular compromise necessitating re-exploration. Free-style free flaps have become a clinical reality. The concepts and techniques used to harvest a free-style free flap will aid in dealing with anatomic variations that are encountered during conventional flap harvest. Future trends in flap selection will focus mainly on choosing tissue with appropriate texture, thickness, and pliability to match requirements at the recipient site while minimizing donor-site morbidity.

  14. [COMPARISON OF REPAIR EFFECT BETWEEN CHIMERIC ANTEROLATERAL THIGH FLAP AND SERIES-WOUND FLAPS FOR DEFECT AFTER RESECTION OF ORAL AND MAXILLOFACIAL CANCER].

    PubMed

    Yang, Heping; Zhang, Hongwu; Chen, Haidi; Yang, Shuxiong; Wang, Jun; Hu, Dawang

    2016-04-01

    To compare the effectiveness of complex defects repair between using chimeric anterolateral thigh flap and series-wound flaps after resection of oral and maxillofacial cancer. After resection of oral and maxillofacial cancer, defect was repaired with chimeric anterolateral thigh flap in 39 patients between January 2011 and July 2014 (chimeric anterolateral thigh flap group); and defect was repaired with series-wound flaps in 35 patients between January 2009 and December 2010 (series-wound flaps group). There was no significant difference in gender, age, duration of disease, tumor type, tumor staging, defect location, and defect area between 2 groups (P > 0.05). The operation time, flap harvesting and microvascular anastomosis time, stomach tube extraction time, and oral feeding time were recorded and compared between 2 groups, and postoperative complications were observed; the effectiveness was evaluated according to clinical efficacy evaluation table of bone and soft tissue defects reconstruction surgery in oral and maxillofacial region. Vascular crisis occurred in 2 cases of chimeric anterolateral thigh flap group, and 4 cases of series-wound flaps group. Partial necrosis appeared at distal end of a series-wound flaps, and oral fistula and infection developed in 3 series-wound flaps. The other flaps and the grafted skin at donor site survived; wounds at recipient site healed by first intention. The operation time, stomach tube extraction time, and oral feeding time of chimeric anterolateral thigh flap group were significantly shorter than those of series-wound flaps group (P < 0.05), while the flap harvesting and microvascular anastomosis time was significantly longer than that of series-wound flaps group (P < 0.05). The patients were followed up 1-5 years (mean, 2.5 years). At 3 months after operation, the appearance, patients' satisfaction, working conditions, oral closure function, chew, language performance, and swallowing scores of the chimeric anterolateral thigh-flap group were significantly better than those of the series-wound flaps group (P < 0.05), while there was no significant difference in diet, mouth opening degree, oral cavity holding water test, and occlusion scores between the 2 groups (P > 0.05). Using chimeric anterolateral thigh flap for defect repair after resection of oral and maxillofacial cancer can significantly shorten the operation time, accelerate postoperative rehabilitation, and help the functional recovery of oral closure, chewing, language performance, swallowing function when compared with the series-wound flaps.

  15. The sensate free superior gluteal artery perforator (S-GAP) flap: a valuable alternative in autologous breast reconstruction.

    PubMed

    Blondeel, P N

    1999-04-01

    The superior and inferior myocutaneous gluteal free flaps have been considered as valuable alternatives to the latissimus dorsi or TRAM flap since 1975. The superior gluteal artery perforator (S-GAP) flap is the ultimate refinement of this myocutaneous flap as no gluteus maximus muscle is harvested. The flap is vascularised by one single perforator originating from the superior gluteal artery. This study summarises the prospectively gathered data on 20 free S-GAP flaps used for breast reconstruction in 16 patients. Immediate reconstruction was performed in six breasts and delayed in 14 breasts. Mean follow-up was 11.1 months. Two risk factors, Raynaud's disease and radiotherapy, were the cause of flap revision in two different patients. Total flap loss occurred in one case. Partial flap loss was not observed and a small area of fat necrosis was diagnosed by mammography in one other patient. All flaps were anastomosed to the internal mammary vessels at the 3rd costochondral junction. The anatomy of the sensate nerves of the S-GAP flap is described. Two nervous repairs provided early sensory recovery. The free S-GAP flap has become my personal second choice for autologous breast reconstruction after the DIEP (deep inferior epigastric perforator) flap. The S-GAP flap is indicated in patients with an asthenic body habitus or with excessive abdominal scarring. The advantages are the abundance of adipose tissue in this area even in thin patients, a long vascular pedicle, a hidden scar, improved projection of the reconstructed breast compared to the DIEP and TRAM flaps and the preservation of the entire gluteus maximus muscle. The donor morbidity is extremely low.

  16. Perforator Propeller Flap for Oncologic Reconstruction of Soft Tissue Defects in Trunk and Extremities.

    PubMed

    Yu, Shengji; Zang, Mengqing; Xu, Libin; Zhao, Zhenguo; Zhang, Xinxin; Zhu, Shan; Chen, Bo; Ding, Qiang; Liu, Yuanbo

    2016-10-01

    Defects after soft tissue sarcoma resection are usually managed by myocutaneous flaps or free flaps. However, harvesting muscle will cause functional morbidities, and some regions lack reliable recipient vessel. Our purpose is to use various perforator propeller flaps for oncologic reconstruction. Between 2008 and 2014, 33 perforator propeller flaps were performed in 24 patients to reconstruct the defects after tumor resection in trunk and extremities. Fifteen patients underwent tumor resection previously. Thirteen patients underwent adjuvant radiotherapy or chemotherapy. Flaps based on perforators adjacent to the lesions were raised and rotated in propeller fashion to repair the defects. Twenty-seven flaps were based on perforators of known source vessels, and 6 were harvested in freestyle fashion. The defects were repaired with 2 flaps in 4 patients and 3 flaps in 2 patients. The mean skin paddle dimension was 8.36 cm in width and 20.42 cm in length. The mean degree of flap rotation was 158.79°. Complications include partial necrosis of 6 flaps in 5 cases and venous congestion of 1 flap. In these 6 patients, 3 underwent adjuvant radiotherapy. The donor sites were primarily closed in 21 patients and skin grafted in 3 patients. No functional loss related to flap harvesting was recognized. The perforator propeller flaps can be used to manage the medium defects in extremities and large defects in torso after soft tissue sarcoma resection. They avoid the sacrifice of the underlying muscle and eliminate the concerns of the unavailability of recipient vessels. The perforator propeller flaps provide flexible options for versatile oncologic reconstruction in trunk and extremities. However, the impact of radiotherapy on the viability of the flaps for local reconstruction needs further investigation.

  17. Medial sural artery perforator flap: a challenging free flap.

    PubMed

    Toyserkani, Navid Mohamadpour; Sørensen, Jens Ahm

    Oral and extremity defect reconstruction can often require a flap that is thin, and traditionally, the radial forearm free flap has been used, however, this has significant donor site morbidity. Over the last decade, the medial sural artery perforator (MSAP) flap has emerged as a possible alternative with lower donor site morbidity. We present our experiences and review the literature regarding this promising but challenging flap. The study was a retrospective case series in a university hospital setting. All patients who had a MSAP flap performed at our institution were included until March 2015, and their data was retrieved from electronic patient records. In total, ten patients were reconstructed with a MSAP flap for floor of mouth (eight) and lower extremity (two) defect reconstruction. The median flap dimensions were as follows: 10 cm (range 7-14 cm), width 5 cm (range 3.5-8 cm), thickness 5 mm (range 4-8 mm), and pedicle length 10 cm (range 8-12 cm). In one case, the procedure was abandoned because of very small perforators and another flap was used. In two cases, late onset of venous congestion occurred which could not be salvaged. There were no donor site complaints. The MSAP flap is an ideal flap when a thin free flap is needed with lower donor site morbidity than alternative solutions. There seems to be a higher rate of late onset of venous thrombosis compared with more established flaps. Therefore, this flap should be monitored more closely for venous problems and we recommend performing two venous anastomoses when using this flap. Level of Evidence: Level IV, therapeutic study.

  18. Rate-determining Step of Flap Endonuclease 1 (FEN1) Reflects a Kinetic Bias against Long Flaps and Trinucleotide Repeat Sequences.

    PubMed

    Tarantino, Mary E; Bilotti, Katharina; Huang, Ji; Delaney, Sarah

    2015-08-21

    Flap endonuclease 1 (FEN1) is a structure-specific nuclease responsible for removing 5'-flaps formed during Okazaki fragment maturation and long patch base excision repair. In this work, we use rapid quench flow techniques to examine the rates of 5'-flap removal on DNA substrates of varying length and sequence. Of particular interest are flaps containing trinucleotide repeats (TNR), which have been proposed to affect FEN1 activity and cause genetic instability. We report that FEN1 processes substrates containing flaps of 30 nucleotides or fewer at comparable single-turnover rates. However, for flaps longer than 30 nucleotides, FEN1 kinetically discriminates substrates based on flap length and flap sequence. In particular, FEN1 removes flaps containing TNR sequences at a rate slower than mixed sequence flaps of the same length. Furthermore, multiple-turnover kinetic analysis reveals that the rate-determining step of FEN1 switches as a function of flap length from product release to chemistry (or a step prior to chemistry). These results provide a kinetic perspective on the role of FEN1 in DNA replication and repair and contribute to our understanding of FEN1 in mediating genetic instability of TNR sequences. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Pedicled Extranasal Flaps in Skull Base Reconstruction

    PubMed Central

    Kim, Grace G.; Hang, Anna X.; Mitchell, Candace; Zanation, Adam M.

    2013-01-01

    Cerebrospinal fluid (CSF) leaks most commonly arise during or after skull base surgery, although they occasionally present spontaneously. Recent advances in the repair of CSF leaks have enabled endoscopic endonasal surgery to become the preferred option for management of skull base pathology. Small defects (<1cm) can be repaired by multilayered free grafts. For large defects (>3cm), pedicled vascular flaps are the repair method of choice, resulting in much lower rates of postoperative CSF leaks. The pedicled nasoseptal flap (NSF) constitutes the primary reconstructive option for the vast majority of skull base defects. It has a large area of potential coverage and high rates of success. However, preoperative planning is required to avoid sacrificing the NSF during resection. In cases where the NSF is unavailable, often due to tumor involvement of the septum or previous resection removing or compromising the flap, other flaps may be considered. These flaps include intranasal options—inferior turbinate (IT) or middle turbinate (MT) flaps—as well as regional pedicled flaps: pericranial flap (PCF), temporoparietal fascial flap (TPFF), or palatal flap (PF). More recently, novel alternatives such as the pedicled facial buccinator flap (FAB) and the pedicled occipital galeopericranial flap (OGP) have been added to the arsenal of options for skull base reconstruction. Characteristics of and appropriate uses for each flap are described. PMID:23257554

  20. Investigation of leading-edge flap performance on delta and double-delta wings at supersonic speeds

    NASA Technical Reports Server (NTRS)

    Covell, Peter F.; Wood, Richard M.; Miller, David S.

    1987-01-01

    An investigation of the aerodynamic performance of leading-edge flaps on three clipped delta and three clipped double-delta wing planforms with aspect ratios of 1.75, 2.11, and 2.50 was conducted in the Langley Unitary Plan Wind Tunnel at Mach numbers of 1.60, 1.90, and 2.16. A primary set of fullspan leading-edge flaps with similar root and tip chords were investigated on each wing, and several alternate flap planforms were investigated on the aspect-ratio-1.75 wings. All leading-edge flap geometries were effective in reducing the drag at lifting conditions over the range of wing aspect ratios and Mach numbers tested. Application of a primary flap resulted in better flap performance with the double-delta planform than with the delta planform. The primary flap geometry generally yielded better performance than the alternate flap geometries tested. Trim drag due to flap-induced pitching moments was found to reduce the leading-edge flap performance more for the delta planform than for the double-delta planform. Flow-visualization techniques showed that leading-edge flap deflection reduces crossflow shock-induced separation effects. Finally, it was found that modified linear theory consistently predicts only the effects of leading-edge flap deflection as related to pitching moment and lift trends.

  1. Mandibular reconstruction in irradiated patients utilizing myosseous-cutaneous flaps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearlman, N.W.; Albin, R.E.; O'Donnell, R.S.

    1983-10-01

    Myosseous-cutaneous flaps were used for mandibular reconstruction in 16 irradiated patients. Three of six sternomastoid-clavicle flaps failed (all in conjunction with a neck dissection), as did one of 10 pectoralis major-anterior-fifth rib flaps. One trapezius-scapular flap was used and it succeeded. We found the blood supply of the sternomastoid-clavicle flap too tenuous for use in conjunction with a neck dissection. The trapezius-scapular flap had too short an arc of rotation to be used for defects other than those in the horizontal ramus. In addition, this flap required a change of position and created an undesirable functional deformity. The pectoralis major-fifthmore » rib flap, in contrast, could be used for a variety of defects, in conjunction with a neck dissection, and did not require a change of position during operation. We found it to be the most versatile and dependable of the flaps employed in this series.« less

  2. A lining vomer flap for palate pushback in unilateral cleft palate repair.

    PubMed

    Clavin, H D; Owsley, J Q

    1978-01-01

    A combinaation vomer mucoperiosteal flap and nasal floor mucoperiosteal flap is described which is used to achieve nasal coverage in unilateral cleft palate patients requiring pushbacks. A posteriorly based readily accessible vomer flap is raised on the cleft side and used as nasal lining for the palatal mucoperiosteal flap on the non-cleft side. On the cleft side, a symmetrically sized nasal floor flap is easily elevated under direct vision and used to cover the nasal aspect of the corresponding mucoperiosteal palatal flap.

  3. An experimental and theoretical study of the aerodynamic characteristics of some generic missile concepts at Mach numbers from 2 to 6.8

    NASA Technical Reports Server (NTRS)

    Spearman, M. Leroy; Braswell, Dorothy O.

    1994-01-01

    A study has been made of the experimental and theoretical aerodynamic characteristics for some generic high-speed missile concepts at Mach numbers from 2 to 6.8. The basic body for this study had a length-to-diameter ratio of 10 with the forward half being a modified blunted ogive and the rear half being a cylinder. Modifications made to the basic body included the addition of an after body flare, the addition of highly swept cruciform wings and the addition of highly swept aft tails. The effects of some controls were also investigated with all-moving wing controls on the flared body and trailing-edge flap controls on the winged body. The results indicated that the addition of a flare, wings, or tails to the basic body all provided static longitudinal stability with varying amounts of increased axial force. The control arrangements were effective in producing increments of normal-force and pitching-moment at the lower Mach numbers. At the highest Mach number, the flap control on the winged body was ineffective in producing normal-force or pitching-moment but the all-moving wing control on the flared body, while losing pitch effectiveness, still provided normal-force increments. Calculated results obtained through the use of hypersonic impact theory were in generally good agreement with experiment at the higher Mach numbers but were not accurate at the lower Mach numbers.

  4. The role of postoperative hematoma on free flap compromise.

    PubMed

    Ahmad, Faisal I; Gerecci, Deniz; Gonzalez, Javier D; Peck, Jessica J; Wax, Mark K

    2015-08-01

    Hematomas may develop in the postoperative setting after free tissue transfer. When hematomas occur, they can exert pressure on surrounding tissues. Their effect on the vascular pedicle of a free flap is unknown. We describe our incidence of hematoma in free flaps and outcomes when the flap is compromised. Retrospective chart review of 1,883 free flaps performed between July 1998 and June 2014 at a tertiary referral center. Patients with free flap compromise due to hematoma were identified. Etiology, demographic data, and outcomes were evaluated. Eighty-eight (4.7%) patients developed hematomas. Twenty (22.7%) of those had flap compromise. Twelve compromises (60%) showed evidence of pedicle thrombosis. The salvage rate was 75% versus 54% in 79 flaps with compromise from other causes (P = .12). Mean time to detection of the hematoma was 35.3 hours in salvaged flaps compared to 91.6 hours in unsalvageable flaps (P = .057). Time to operating room (OR) from detection was 2.8 hours in salvageable flaps compared to 12.4 hours in nonsalvageable flaps (P = .053). The salvage rate for flaps that returned to the OR in <5 hours was 93.3% compared to 20% (P = .0049) for those that did not. Vascular thrombosis reduced salvage rate to 58.3% from 100% (P = .002) when there was no thrombosis. In our series hematomas developed rarely. When they did, 23% went on to develop flap compromise. Prompt recognition and re-exploration allowed for a high salvage rate. Vessel thrombosis predicted inability to salvage the flap. 4 © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  5. The trapezius perforator flap: an underused but versatile option in the reconstruction of local and distant soft-tissue defects.

    PubMed

    Sadigh, Parviz L; Chang, Li-Ren; Hsieh, Ching-Hua; Feng, Wen-Jui; Jeng, Seng-Feng

    2014-09-01

    The trapezius myocutaneous flap is an established reconstructive option in head and neck cases The authors present their experience with 10 trapezius perforator flaps, all raised using a freestyle technique of perforator dissection, to successfully reconstruct both local and distant soft-tissue defects. Ten patients underwent soft-tissue reconstruction using trapezius perforator flaps. After mapping the perforator with a handheld Doppler device at the intersection of a horizontal line drawn 6 to 8 cm inferior to the scapular spine and a vertical line drawn 8 to 9 cm lateral to the midline of the back, perforator flaps were raised in a freestyle fashion, with complete preservation of the trapezius muscle. The flap can be pedicled into local defects or transferred as a free flap. Six flaps were elevated as pedicled flaps and four were transferred as free flaps. Flap size ranged from 6 × 4 cm to 25 × 15 cm. The pedicle length ranged from 4 to 14 cm. The pedicle originated from the dorsal scapular artery. In one case, the authors converted from a pedicled flap to a free flap secondary to insufficient pedicle length. All donor sites were closed directly. The follow-up period ranged from 4 months to 4 years. All of the flaps survived completely with no major complications, and no patients developed any shoulder dysfunction. The trapezius perforator flap is a reliable and versatile reconstructive option that can be used to repair both local and distant soft-tissue defects. The donor-site morbidity is minimal. Therapeutic, IV.

  6. Comparison of gluteal perforator flaps and gluteal fasciocutaneous rotation flaps for reconstruction of sacral pressure sores.

    PubMed

    Chen, Yen-Chou; Huang, Eng-Yen; Lin, Pao-Yuan

    2014-03-01

    The gluteus maximus myocutaneous flap was considered the workhorse that reconstructed sacral pressure sores, but was gradually replaced by fasciocutaneous flap because of several disadvantages. With the advent of the perforator flap technique, gluteal perforator (GP) flap has gained popularity nowadays. The aim of this study was to compare the complications and outcomes between GP flaps and gluteal fasciocutaneous rotation (FR) flaps in the treatment of sacral pressure sores. Between April 2007 and June 2012, 63 patients underwent sacral pressure sore reconstructions, with a GP flap used in 31 cases and an FR flap used in 32 cases. Data collected on the patients included patient age, gender, co-morbidity for being bedridden and follow-up time. Surgical details collected included the defect size, operative time and estimated blood loss. Complications recorded included re-operation, dehiscence, flap necrosis, wound infection, sinus formation, donor-site morbidity and recurrence. The complications and clinical outcomes were compared between these two groups. We found that there was no significant difference in patient demographics, surgical complications and recurrence between these two groups. In gluteal FR flap group, all recurrent cases (five) were treated by reuse of previous flaps. Both methods are comparable, good and safe in treating sacral pressure sores. Gluteal FR flap can be performed without microsurgical dissection, and re-rotation is feasible in recurrent cases. The authors suggest using gluteal FR flaps in patients with a high risk of sore recurrence. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Pectoralis Major Musculocutaneous Flap With a Midline Sternal Skin Paddle for Head and Neck Reconstruction: A New Design.

    PubMed

    Oh, Jeongseok; Ahn, Hee Chang; Youn, Seungki; Tae, Kyung

    2018-05-14

    The pectoralis major musculocutaneous (PMMC) flap is a classic flap for head and neck reconstruction, relatively unpopular with the advancement of microsurgery and free flaps. The classic parasternal paddle design provided a thick flap with a small rotation arch leaving objectionable scarring. Our new symmetric midsternal design overcomes these problems. Chart review was done from the years 2000 to 2017. Flap skin paddle was placed symmetrically on both sides of the midsternal line. The pectoralis major (PM) muscle and aponeurosis were attached in the lateral half of the skin paddle. Most of PM muscle was elevated with the thoracoacromial vessel and dissected to the main trunk, where the PM muscle was cut and used for bulk. The flap was transferred to the neck and lower mandibular area. The flap was inset either supraclavicularly, covering the anterior neck, or subclavicularly, for intraoral/maxillary defects. Eight patients underwent head and neck reconstruction using the new design of PMMC flap between the years 2000 and 2017. The etiologies of the defect were radiation necrosis in 3 patients, repair of cutaneous fistulas in 3, recurrent hypopharyngeal cancer in 1, and recurrent tongue cancer in 1 patient. There were no flap losses or major complications. With the advancement of free-flap techniques, the classic flaps have become less popular. Our new design supplements the PMMC flap by providing a thin pliable flap with a long pedicle and rotation arc, allowing a combination of different types of flaps to cover composite head and neck defects, especially in cases that lack a reliable recipient vessel due to radiation.

  8. Axial-type olivine crystallographic preferred orientations: The effect of strain geometry on mantle texture

    NASA Astrophysics Data System (ADS)

    Chatzaras, Vasileios; Kruckenberg, Seth C.; Cohen, Shaina M.; Medaris, L. Gordon; Withers, Anthony C.; Bagley, Brian

    2016-07-01

    The effect of finite strain geometry on crystallographic preferred orientation (CPO) is poorly constrained in the upper mantle. Specifically, the relationship between shape preferred orientation (SPO) and CPO in mantle rocks remains unclear. We analyzed a suite of 40 spinel peridotite xenoliths from Marie Byrd Land, West Antarctica. X-ray computed tomography allows for quantification of spinel SPO, which ranges from prolate to oblate shape. Electron backscatter diffraction analysis reveals a range of olivine CPO patterns, including A-type, axial-[010], axial-[100], and B-type patterns. Until now, these CPO types were associated with different deformation conditions, deformation mechanisms, or strain magnitudes. Microstructures and deformation mechanism maps suggest that deformation in all studied xenoliths is dominated by dislocation-accommodated grain boundary sliding. For the range of temperatures (780-1200°C), extraction depths (39-72 km), differential stresses (2-60 MPa), and water content (up to 500 H/106Si) of the xenolith suite, variations in olivine CPO do not correlate with changes in deformation conditions. Here we establish for the first time in naturally deformed mantle rocks that finite strain geometry controls the development of axial-type olivine CPOs; axial-[010] and axial-[100] CPOs form in relation to oblate and prolate fabric ellipsoids, respectively. Girdling of olivine crystal axes results from intracrystalline slip with activation of multiple slip systems and grain boundary sliding. Our results demonstrate that mantle deformation may deviate from simple shear. Olivine texture in field studies and seismic anisotropy in geophysical investigations can provide critical constraints for the 3-D strain in the upper mantle.

  9. Free Flap Reconstruction Monitoring Techniques and Frequency in the Era of Restricted Resident Work Hours.

    PubMed

    Patel, Urjeet A; Hernandez, David; Shnayder, Yelizaveta; Wax, Mark K; Hanasono, Matthew M; Hornig, Joshua; Ghanem, Tamer A; Old, Matthew; Jackson, Ryan S; Ledgerwood, Levi G; Pipkorn, Patrik; Lin, Lawrence; Ong, Adrian; Greene, Joshua B; Bekeny, James; Yiu, Yin; Noureldine, Salem; Li, David X; Fontanarosa, Joel; Greenbaum, Evan; Richmon, Jeremy D

    2017-08-01

    Free flap reconstruction of the head and neck is routinely performed with success rates around 94% to 99% at most institutions. Despite experience and meticulous technique, there is a small but recognized risk of partial or total flap loss in the postoperative setting. Historically, most microvascular surgeons involve resident house staff in flap monitoring protocols, and programs relied heavily on in-house resident physicians to assure timely intervention for compromised flaps. In 2003, the Accreditation Council for Graduate Medical Education mandated the reduction in the hours a resident could work within a given week. At many institutions this new era of restricted resident duty hours reshaped the protocols used for flap monitoring to adapt to a system with reduced resident labor. To characterize various techniques and frequencies of free flap monitoring by nurses and resident physicians; and to determine if adapted resident monitoring frequency is associated with flap compromise and outcome. This multi-institutional retrospective review included patients undergoing free flap reconstruction to the head and/or neck between January 2005 and January 2015. Consecutive patients were included from different academic institutions or tertiary referral centers to reflect evolving practices. Technique, frequency, and personnel for flap monitoring; flap complications; and flap success. Overall, 1085 patients (343 women [32%] and 742 men [78%]) from 9 institutions were included. Most patients were placed in the intensive care unit postoperatively (n = 790 [73%]), while the remaining were placed in intermediate care (n = 201 [19%]) or in the surgical ward (n = 94 [7%]). Nurses monitored flaps every hour (q1h) for all patients. Frequency of resident monitoring varied, with 635 patients monitored every 4 hours (q4h), 146 monitored every 8 hours (q8h), and 304 monitored every 12 hours (q12h). Monitoring techniques included physical examination (n = 949 [87%]), handheld external Doppler sonography (n = 739 [68%]), implanted Doppler sonography (n = 333 [31%]), and needle stick (n = 349 [32%]); 105 patients (10%) demonstrated flap compromise, prompting return to the operating room in 96 patients. Of these 96 patients, 46 had complete flap salvage, 22 had partial loss, and 37 had complete loss. The frequency of resident flap checks did not affect the total flap loss rate (q4h, 25 patients [4%]; q8h, 8 patients [6%]; and q12h, 8 patients [3%]). Flap salvage rates for compromised flaps were not statistically different. Academic centers rely primarily on q1h flap checks by intensive care unit nurses using physical examination and Doppler sonography. Reduced resident monitoring frequency did not alter flap salvage nor flap outcome. These findings suggest that institutions may successfully monitor free flaps with decreased resident burden.

  10. Influence of two different flap designs on the sequelae of mandibular third molar surgery.

    PubMed

    Erdogan, Ozgür; Tatlı, Ufuk; Ustün, Yakup; Damlar, Ibrahim

    2011-09-01

    The aim of this study was to compare the influence of triangular and envelope flaps on trismus, pain, and facial swelling after mandibular third molar surgery. Twenty healthy patients with bilateral, symmetrically impacted mandibular third molars were included in this double-blinded, prospective, cross-over, randomized study. The patients were operated with envelope flap on one side and triangular flap on the other side. Trismus was determined by measuring maximum interincisal opening, and facial swelling was evaluated using a tape measuring method. Pain was determined using visual analog scale (VAS) and recording the number of pain pills taken. The facial swelling measurements and VAS scores were lower in the envelope flap group compared to the triangular flap group. There was no significant difference between the two flap designs in operation time, maximum interincisal opening, and the number of analgesics taken. Envelope flap yields to less facial swelling and reduced VAS scores in comparison to triangular flap. There is no clinical difference in trismus between the two flap designs. Despite the higher VAS scores with triangular flap, no additional doses of analgesics were required in triangular flap.

  11. Effect of topically applied minoxidil on the survival of rat dorsal skin flap.

    PubMed

    Gümüş, Nazım; Odemiş, Yusuf; Yılmaz, Sarper; Tuncer, Ersin

    2012-12-01

    Flap necrosis still is a challenging problem in reconstructive surgery that results in irreversible tissue loss. This study evaluated the effect of topically applied minoxidil on angiogenesis and survival of a caudally based dorsal rat skin flap. For this study, 24 male Wistar rats were randomly divided into three groups of eight each. A caudally based dorsal skin flap with the dimensions of 9 × 3 cm was raised. After elevation of the flaps, they were sutured back into their initial positions. In group 1 (control group), 1 ml of isotonic saline was applied topically to the flaps of all the animals for 14 days. In group 2, minoxidil solution was spread uniformly over the flap surface for 7 days after the flap elevation. In group 3, minoxidil solution was applied topically to the flap surface during a 14-day period. On day 7 after the flap elevation, the rats were killed. The average area of flap survival was determined for each rat. Subdermal vascular architecture and angiogenesis were evaluated under a light microscope after two full-thickness skin biopsy specimens had been obtained from the midline of the flaps. The lowest flap survival rate was observed in group 1, and no difference was observed between groups 1 and 2. Compared with groups 1 and 2, group 3 had a significantly increased percentage of flap survival (P < 0.05). Intense and moderate angiogenesis also was observed respectively at the proximal and distal areas of the flaps in group 3. The results of this experiment seem to show that the early effect of minoxidil is vasodilation and that prolonged use before flap elevation leads to angiogenesis, increasing flap viability. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  12. Classification and Microvascular Flap Selection for Anterior Cranial Fossa Reconstruction.

    PubMed

    Vargo, James D; Przylecki, Wojciech; Camarata, Paul J; Andrews, Brian T

    2018-05-18

     Microvascular reconstruction of the anterior cranial fossa (ACF) creates difficult challenges. Reconstructive goals and flap selection vary based on the defect location within the ACF. This study evaluates the feasibility and reliability of free tissue transfer for salvage reconstruction of low, middle, and high ACF defects.  A retrospective review was performed. Reconstructions were anatomically classified as low (anterior skull base), middle (frontal bar/sinus), and high (frontal bone/soft tissue). Subjects were evaluated based on pathologic indication and goal, type of flap used, and complications observed.  Eleven flaps in 10 subjects were identified and anatomic sites included: low ( n  = 5), middle ( n  = 3), and high ( n  = 3). Eight of 11 reconstructions utilized osteocutaneous flaps including the osteocutaneous radial forearm free flap (OCRFFF) ( n  = 7) and fibula ( n  = 1). Other reconstructions included a split calvarial graft wrapped within a temporoparietal fascia free flap ( n  = 1), latissimus myocutaneous flap ( n  = 1), and rectus abdominis myofascial flap ( n  = 1). All 11 flaps were successful without microvascular compromise. No complications were observed in the high and middle ACF defect groups. Two of five flaps in the low defect group using OCRFFF flaps failed to achieve surgical goals despite demonstrating healthy flaps upon re-exploration. Complications included persistent cerebrospinal fluid leak ( n  = 1) and pneumocephalus ( n  = 1), requiring flap repositioning in one subject and a second microvascular flap in the second subject to achieve surgical goals.  In our experience, osteocutaneous flaps (especially the OCRFFF) are preferred for complete autologous reconstruction of high and middle ACF defects. Low skull base defects are more difficult to reconstruct, and consideration of free muscle flaps (no bone) should be weighed as an option in this anatomic area. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. An experimental study of pressures on 60 deg Delta wings with leading edge vortex flaps

    NASA Technical Reports Server (NTRS)

    Marchman, J. F., III; Terry, J. E.; Donatelli, D. A.

    1983-01-01

    An experimental study was conducted in the Virginia Tech Stability Wind Tunnel to determine surface pressures over a 60 deg sweep delta wing with three vortex flap designs. Extensive pressure data was collected to provide a base data set for comparison with computational design codes and to allow a better understanding of the flow over vortex flaps. The results indicated that vortex flaps can be designed which will contain the leading edge vortex with no spillage onto the wing upper surface. However, the tests also showed that flaps designed without accounting for flap thickness will not be optimum and the result can be oversized flaps, early flap vortex reattachment and a second separation and vortex at the wing/flap hinge line.

  14. Risk factors for pedicled flap necrosis in hand soft tissue reconstruction: a multivariate logistic regression analysis.

    PubMed

    Gong, Xu; Cui, Jianli; Jiang, Ziping; Lu, Laijin; Li, Xiucun

    2018-03-01

    Few clinical retrospective studies have reported the risk factors of pedicled flap necrosis in hand soft tissue reconstruction. The aim of this study was to identify non-technical risk factors associated with pedicled flap perioperative necrosis in hand soft tissue reconstruction via a multivariate logistic regression analysis. For patients with hand soft tissue reconstruction, we carefully reviewed hospital records and identified 163 patients who met the inclusion criteria. The characteristics of these patients, flap transfer procedures and postoperative complications were recorded. Eleven predictors were identified. The correlations between pedicled flap necrosis and risk factors were analysed using a logistic regression model. Of 163 skin flaps, 125 flaps survived completely without any complications. The pedicled flap necrosis rate in hands was 11.04%, which included partial flap necrosis (7.36%) and total flap necrosis (3.68%). Soft tissue defects in fingers were noted in 68.10% of all cases. The logistic regression analysis indicated that the soft tissue defect site (P = 0.046, odds ratio (OR) = 0.079, confidence interval (CI) (0.006, 0.959)), flap size (P = 0.020, OR = 1.024, CI (1.004, 1.045)) and postoperative wound infection (P < 0.001, OR = 17.407, CI (3.821, 79.303)) were statistically significant risk factors for pedicled flap necrosis of the hand. Soft tissue defect site, flap size and postoperative wound infection were risk factors associated with pedicled flap necrosis in hand soft tissue defect reconstruction. © 2017 Royal Australasian College of Surgeons.

  15. Reconstruction of a 10-mm-long median nerve gap in an ischemic environment using autologous conduits with different patterns of blood supply: A comparative study in the rat

    PubMed Central

    Iria, Inês; Alves, Sara; Farinho, Ana; Pen, Cláudia; Lourenço-Silva, Nuno; Mascarenhas-Lemos, Luís; Silva-Ferreira, José; Ferraz-Oliveira, Mário; Vassilenko, Valentina; Videira, Paula Alexandra; Goyri-O’Neill, João; Pais, Diogo

    2018-01-01

    The aim of this study was to evaluate in the Wistar rat the efficacy of various autologous nerve conduits with various forms of blood supply in reconstructing a 10-mm-long gap in the median nerve (MN) under conditions of local ischemia. A 10-mm-long median nerve defect was created in the right arm. A loose silicone tube was placed around the nerve gap zone, in order to simulate a local ischemic environment. Rats were divided in the following experimental groups (each with 20 rats): the nerve Graft (NG) group, in which the excised MN segment was reattached; the conventional nerve flap (CNF) and the arterialized neurovenous flap (ANVF) groups in which the gap was bridged with homonymous median nerve flaps; the prefabricated nerve flap (PNF) group in which the gap was reconstructed with a fabricated flap created by leaving an arteriovenous fistula in contact with the sciatic nerve for 5 weeks; and the two control groups, Sham and Excision groups. In the latter group, the proximal stump of the MN nerve was ligated and no repair was performed. The rats were followed for 100 days. During this time, they did physiotherapy. Functional, electroneuromyographic and histological studies were performed. The CNF and ANVF groups presented better results than the NG group in the following assessments: grasping test, nociception, motor stimulation threshold, muscle weight, and histomorphometric evaluation. Radial deviation of the operated forepaw was more common in rats that presented worse results in the other outcome variables. Overall, CNFs and ANVFs produced a faster and more complete recovery than NGs in the reconstruction of a 10-mm-long median nerve gap in an ischemic environment in the Wistar rat. Although, results obtained with CNFs were in most cases were better than ANVFs, these differences were not statistically significant for most of the outcome variables. PMID:29659600

  16. Fully localized post-buckling states of cylindrical shells under axial compression

    NASA Astrophysics Data System (ADS)

    Kreilos, Tobias; Schneider, Tobias M.

    2017-09-01

    We compute nonlinear force equilibrium solutions for a clamped thin cylindrical shell under axial compression. The equilibrium solutions are dynamically unstable and located on the stability boundary of the unbuckled state. A fully localized single dimple deformation is identified as the edge state-the attractor for the dynamics restricted to the stability boundary. Under variation of the axial load, the single dimple undergoes homoclinic snaking in the azimuthal direction, creating states with multiple dimples arranged around the central circumference. Once the circumference is completely filled with a ring of dimples, snaking in the axial direction leads to further growth of the dimple pattern. These fully nonlinear solutions embedded in the stability boundary of the unbuckled state constitute critical shape deformations. The solutions may thus be a step towards explaining when the buckling and subsequent collapse of an axially loaded cylinder shell is triggered.

  17. Navier-Stokes Computations of a Wing-Flap Model With Blowing Normal to the Flap Surface

    NASA Technical Reports Server (NTRS)

    Boyd, D. Douglas, Jr.

    2005-01-01

    A computational study of a generic wing with a half span flap shows the mean flow effects of several blown flap configurations. The effort compares and contrasts the thin-layer, Reynolds averaged, Navier-Stokes solutions of a baseline wing-flap configuration with configurations that have blowing normal to the flap surface through small slits near the flap side edge. Vorticity contours reveal a dual vortex structure at the flap side edge for all cases. The dual vortex merges into a single vortex at approximately the mid-flap chord location. Upper surface blowing reduces the strength of the merged vortex and moves the vortex away from the upper edge. Lower surface blowing thickens the lower shear layer and weakens the merged vortex, but not as much as upper surface blowing. Side surface blowing forces the lower surface vortex farther outboard of the flap edge by effectively increasing the aerodynamic span of the flap. It is seen that there is no global aerodynamic penalty or benefit from the particular blowing configurations examined.

  18. Reconstruction of lower face defect or deformity with submental artery perforator flaps.

    PubMed

    Shi, Cheng-li; Wang, Xian-cheng

    2012-07-01

    Reconstruction of lower face defects or deformity often presents as a challenge for plastic surgeons. Many methods, including skin graft, tissue expander, or free flap are introduced. Submental artery perforator flaps have been used in the reconstruction of defects or deformities of the lower face. Between August 2006 and December 2008, 22 patients with lower face defects or deformity underwent reconstruction with pedicled submental artery perforator flaps. Their age ranged between 14 and 36 years. The perforator arteries were detected and labeled with a hand-held Doppler flowmeter. The size of flaps ranged from 4 × 6 to 6 × 7 cm, and the designed flaps included the perforator artery. All the flaps survived well, except 1 flap which resulted in partial necrosis in distal region and healed after conservative therapy. No other complication occurred with satisfactory aesthetic appearance of the donor site. The submental artery perforator flap is a thin and reliable flap with robust blood supply. This flap can reduce donor-site morbidity significantly and is a good choice for reconstructive surgery of lower face.

  19. Estimation of blade airloads from rotor blade bending moments

    NASA Technical Reports Server (NTRS)

    Bousman, William G.

    1987-01-01

    A method is developed to estimate the blade normal airloads by using measured flap bending moments; that is, the rotor blade is used as a force balance. The blade's rotation is calculated in vacuum modes and the airloads are then expressed as an algebraic sum of the mode shapes, modal amplitudes, mass distribution, and frequency properties. The modal amplitudes are identified from the blade bending moments using the Strain Pattern Analysis Method. The application of the method is examined using simulated flap bending moment data that have been calculated for measured airloads for a full-scale rotor in a wind tunnel. The estimated airloads are compared with the wind tunnel measurements. The effects of the number of measurements, the number of modes, and errors in the measurements and the blade properties are examined, and the method is shown to be robust.

  20. Aerodynamic characteristics of a wing with Fowler flaps including flap loads, downwash, and calculated effect on take-off

    NASA Technical Reports Server (NTRS)

    Platt, Robert C

    1936-01-01

    This report presents the results of wind tunnel tests of a wing in combination with each of three sizes of Fowler flap. The purpose of the investigation was to determine the aerodynamic characteristics as affected by flap chord and position, the air loads on the flaps, and the effect of flaps on the downwash.

  1. Face resurfacing using a cervicothoracic skin flap prefabricated by lateral thigh fascial flap and tissue expander.

    PubMed

    Li, Qingfeng; Zan, Tao; Gu, Bin; Liu, Kai; Shen, Guoxiong; Xie, Yun; Weng, Rui

    2009-01-01

    Resurfacing of facial massive soft tissue defect is a formidable challenge because of the unique character of the region and the limitation of well-matched donor site. In this report, we introduce a technique for using the prefabricated cervicothoracic skin flap for facial resurfacing, in an attempt to meet the principle of flap selection in face reconstructive surgery for matching the color and texture, large dimension, and thinner thickness (MLT) of the recipient. Eleven patients with massive facial scars underwent resurfacing procedures with prefabricated cervicothoracic flaps. The vasculature of the lateral thigh fascial flap, including the descending branch of the lateral femoral circumflex vessels and the surrounding muscle fascia, was used as the vascular carrier, and the pedicles of the fascial flap were anastomosed to either the superior thyroid or facial vessels in flap prefabrication. A tissue expander was placed beneath the fascial flap to enlarge the size and reduce the thickness of the flap. The average size of the harvested fascia flap was 6.5 x 11.7 cm. After a mean interval of 21.5 weeks, the expanders were filled to a mean volume of 1,685 ml. The sizes of the prefabricated skin flaps ranged from 12 x 15 cm to 15 x 32 cm. The prefabricated skin flaps were then transferred to the recipient site as pedicled flaps for facial resurfacing. All facial soft tissue defects were successfully covered by the flaps. The donor sites were primarily closed and healed without complications. Although varied degrees of venous congestion were developed after flap transfers, the marginal necrosis only occurred in two cases. The results in follow-up showed most resurfaced faces restored natural contour and regained emotional expression. MLT is the principle for flap selection in resurfacing of the massive facial soft tissue defect. Our experience in this series of patients demonstrated that the prefabricated cervicothoracic skin flap could be a reliable alternative tool for resurfacing of massive facial soft tissue defects. (c) 2009 Wiley-Liss, Inc. Microsurgery, 2009.

  2. Remotely sensed wind speed predicts soaring behaviour in a wide-ranging pelagic seabird.

    PubMed

    Gibb, Rory; Shoji, Akiko; Fayet, Annette L; Perrins, Chris M; Guilford, Tim; Freeman, Robin

    2017-07-01

    Global wind patterns affect flight strategies in many birds, including pelagic seabirds, many of which use wind-powered soaring to reduce energy costs during at-sea foraging trips and migration. Such long-distance movement patterns are underpinned by local interactions between wind conditions and flight behaviour, but these fine-scale relationships are far less well understood. Here we show that remotely sensed ocean wind speed and direction are highly significant predictors of soaring behaviour in a migratory pelagic seabird, the Manx shearwater ( Puffinus puffinus ). We used high-frequency GPS tracking data (10 Hz) and statistical behaviour state classification to identify two energetic modes in at-sea flight, corresponding to flap-like and soar-like flight. We show that soaring is significantly more likely to occur in tailwinds and crosswinds above a wind speed threshold of around 8 m s -1 , suggesting that these conditions enable birds to reduce metabolic costs by preferentially soaring over flapping. Our results suggest a behavioural mechanism by which wind conditions may shape foraging and migration ecology in pelagic seabirds, and thus indicate that shifts in wind patterns driven by climate change could impact this and other species. They also emphasize the emerging potential of high-frequency GPS biologgers to provide detailed quantitative insights into fine-scale flight behaviour in free-living animals. © 2017 The Author(s).

  3. Application of multidetector-row computed tomography in propeller flap planning.

    PubMed

    Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko

    2011-02-01

    The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.

  4. Comparison of fasciocutaneous V-Y and rotational flaps for defect coverage of sacral pressure sores: a critical single-centre appraisal.

    PubMed

    Djedovic, Gabriel; Metzler, Julia; Morandi, Evi M; Wachter, Tanja; Kühn, Shafreena; Pierer, Gerhard; Rieger, Ulrich M

    2017-12-01

    Pressure sore rates remain high in both nursing homes as well as in hospitals. Numerous surgical options are available for defect coverage in the sacral region. However, objective data is scarce as to whether a specific flap design is superior to another. Here, we aim to compare two fasciocutaneous flap designs for sacral defect coverage: the gluteal rotation flap and the gluteal V-Y flap. All primary sacral pressure sores of grades III-IV that were being covered with gluteal fasciocutaneous rotational or V-Y flaps between January 2008 and December 2014 at our institution were analysed. A total of 41 patients received a total of 52 flaps. Of these, 18 patients received 20 gluteal rotational flaps, and 23 patients received 32 V-Y flaps. Both groups were comparable with regards to demographics, comorbidities and complications. Significantly more V-Y flaps were needed to cover smaller defects. Mean length of hospital stay was significantly prolonged when surgical revision had to be carried out. Both flap designs have proven safe and reliable for defect coverage after sacral pressure sores. Gluteal rotational flaps appear to be more useful for larger defects. Both flap designs facilitate their reuse in case of pressure sore recurrence. Complication rates appear to be comparable in both designs and to the current literature. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Glove box shield

    DOEpatents

    Brackenbush, L.W.; Hoenes, G.R.

    A shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user wthdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.

  6. Magnitude of Myocutaneous Flaps and Factors Associated With Loss of Volume in Oral Cancer Reconstructive Surgery.

    PubMed

    Sakamoto, Yuki; Yanamoto, Souichi; Ota, Yoshihide; Furudoi, Shungo; Komori, Takahide; Umeda, Masahiro

    2016-03-01

    Myocutaneous flaps are often used to repair oral and maxillofacial defects after surgery for oral cancer; however, their volume decreases during the postoperative period. To facilitate treatment planning, the authors measured the extent of such postoperative flap volume loss and identified associated factors in patients who underwent oral reconstruction with myocutaneous flaps. The authors designed and performed a retrospective observational study of patients who underwent reconstructive procedures involving rectus abdominal myocutaneous (RAM) or pectoralis major myocutaneous (PMMC) flaps at Tokai University Hospital, Kobe University Hospital, or Nagasaki University Hospital from April 2009 through March 2013. Flap type and other clinical variables were examined as potential predictors of flap loss. The primary outcome was flap loss at 6 months postoperatively. Correlations between each potential predictor and the primary outcome were examined using multiple regression analysis. The subjects were 75 patients whose oral defects were reconstructed with RAM flaps (n = 57) or PMMC flaps (n = 18). RAM flaps exhibited a mean volume shrinkage of 22% at 6 months postoperatively, which was less than the 27.5% displayed by the PMMC flaps, but the difference was not important. Renal failure, previous surgery of the oral region, postoperative radiotherapy, and postoperative serum albumin level were found to be meaningful risk factors for postoperative flap volume loss. The results of this study suggest that larger flaps should be used in patients who possess these risk factors or are scheduled to undergo postoperative radiotherapy. Future studies should examine the utility of postoperative nutritional management for preventing flap volume loss. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. [Management of vascular crisis of free flaps after reconstruction of head and neck defects caused by tumor resection].

    PubMed

    Ni, Song; Zhu, Yiming; Li, Dezhi; Liu, Jie; An, Changming; Zhang, Bin; Liu, Shaoyan

    2015-11-01

    To discuss the management of vascular crisis of free flaps after reconstruction of head and neck defects caused by tumor resection. A total of 259 cases of free flap reconstruction performed in the Cancer Hospital of Chinese Academy of Medical Sciences from 2010 to 2013 were retrospectively analyzed, including 89 cases of anterolateral thigh flaps, 48 cases of radial forearm flaps, 46 free fibula flaps, 5 cases of inferior epigastric artery perforator flaps, 5 cases of free latissimus dorsi flaps, one case of lateral arm flap, and one case of medial femoral flap. The surveillance frequency of free flaps was q1h on post-operative day (POD) 1, q2h on POD 2 and 3, and q4h after POD 3. Vascular crises were reviewed for analysis. The incidence rate of vascular crisis was 8.1% (21/259), with 15 males and 6 females. The average age was 54.8 years old (17-68), and the average time of vascular crisis was 100.8 h post-operation (3-432). There were 7 cases of free jejunum flaps and 14 dermal free flaps. Seven of these 21 cases with vascular crisis were rescued by surgery. The success rate of salvage surgery within 72 hours from the primary operation was 54.5% (6/11), significantly higher than that of salvage surgery performed later than 72 hours from primary operation (10.0%, 1/10, P=0.043). There were 14 cases of flap necrosis, two of which died of local infection. Early detection of vascular crisis can effectively improve the success rate of salvage, so as to avoid the serious consequences caused by free flap necrosis.

  8. The importance of leading edge vortices under simplified flapping flight conditions at the size scale of birds.

    PubMed

    Hubel, Tatjana Y; Tropea, Cameron

    2010-06-01

    Over the last decade, interest in animal flight has grown, in part due to the possible use of flapping propulsion for micro air vehicles. The importance of unsteady lift-enhancing mechanisms in insect flight has been recognized, but unsteady effects were generally thought to be absent for the flapping flight of larger animals. Only recently has the existence of LEVs (leading edge vortices) in small vertebrates such as swifts, small bats and hummingbirds been confirmed. To study the relevance of unsteady effects at the scale of large birds [reduced frequency k between 0.05 and 0.3, k=(pifc)/U(infinity); f is wingbeat frequency, U(infinity) is free-stream velocity, and c is the average wing chord], and the consequences of the lack of kinematic and morphological refinements, we have designed a simplified goose-sized flapping model for wind tunnel testing. The 2-D flow patterns along the wing span were quantitatively visualized using particle image velocimetry (PIV), and a three-component balance was used to measure the forces generated by the wings. The flow visualization on the wing showed the appearance of LEVs, which is typically associated with a delayed stall effect, and the transition into flow separation. Also, the influence of the delayed stall and flow separation was clearly visible in measurements of instantaneous net force over the wingbeat cycle. Here, we show that, even at reduced frequencies as low as those of large bird flight, unsteady effects are present and non-negligible and have to be addressed by kinematic and morphological adaptations.

  9. Reconstruction Using Locoregional Flaps for Large Skull Base Defects.

    PubMed

    Hatano, Takaharu; Motomura, Hisashi; Ayabe, Shinobu

    2015-06-01

    We present a modified locoregional flap for the reconstruction of large anterior skull base defects that should be reconstructed with a free flap according to Yano's algorithm. No classification of skull base defects had been proposed for a long time. Yano et al suggested a new classification in 2012. The lb defect of Yano's classification extends horizontally from the cribriform plate to the orbital roof. According to Yano's algorithm for subsequent skull base reconstructive procedures, a lb defect should be reconstructed with a free flap such as an anterolateral thigh free flap or rectus abdominis myocutaneous free flap. However, our modified locoregional flap has also enabled reconstruction of lb defects. In this case series, we used a locoregional flap for lb defects. No major postoperative complications occurred. We present our modified locoregional flap that enables reconstruction of lb defects.

  10. Reconstructive Trends in Post-Ablation Patients with Esophagus and Hypopharynx Defect

    PubMed Central

    Choi, Jong Hwan; Sim, Seung Hyun

    2015-01-01

    The main challenge in pharyngoesophageal reconstruction is the restoration of swallow and speech functions. The aim of this paper is to review the reconstructive options and associated complications for patients with head and neck cancer. A literature review was performed for pharynoesophagus reconstruction after ablative surgery of head and neck cancer for studies published between January 1980 to July 2015 and listed in the PubMed database. Search queries were made using a combination of 'esophagus' and 'free flap', 'microsurgical', or 'free tissue transfer'. The search query resulted in 123 studies, of which 33 studies were full text publications that met inclusion criteria. Further review into the reference of these 33 studies resulted in 15 additional studies to be included. The pharyngoesophagus reconstruction should be individualized for each patient and clinical context. Fasciocutaneous free flap and pedicled flap are effective for partial phayngoesophageal defect. Fasciocutaneous free flap and jejunal free flap are effective for circumferential defect. Pedicled flaps remain a safe option in the context of high surgical risk patients, presence of fistula. Among free flaps, anterolateral thigh free flap and jejunal free flap were associated with superior outcomes, when compared with radial forearm free flap. Speech function is reported to be better for the fasciocutaneous free flap than for the jejunal free flap. PMID:28913234

  11. Proximally pedicled medial plantar flap based on superficial venous system alone for venous drainage.

    PubMed

    Wright, Thomas C; Mossaad, Bassem M; Chummun, Shaheel; Khan, Umraz; Chapman, Thomas W L

    2013-07-01

    The proximally pedicled medial plantar flap is well described for coverage of wounds around the ankle and heel. This flap is usually based on the deep venae comitantes for venous drainage, with the superficial veins divided during dissection. Usually any disruption of the deep venous system of the flap would result in abandoning this choice of flap. Venous congestion is a recognised complication of medial plantar flaps. The patient described in this case report had a medial ankle defect with exposed bone, for which a proximally pedicled medial plantar flap was used. As we raised the flap, both venae comitantes of the medial planter artery were found to be disrupted. The flap was raised based on the superficial veins draining into the great saphenous, as the only system for venous drainage, with no evidence of venous congestion. The flap was successfully transposed into the defect and healed with no complications. The proximally pedicled medial plantar flap can safely rely on the superficial venous system alone for drainage. In addition, preserving the superficial veins minimise the risk of venous congestion in this flap. We recommend preservation of superficial venous system when possible. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Reconstruction of cubital fossa skin necrosis with radial collateral artery perforator-based propeller flap (RCAP).

    PubMed

    Chaput, B; Gandolfi, S; Ho Quoc, C; Chavoin, J-P; Garrido, I; Grolleau, J-L

    2014-02-01

    In recent years, perforator flaps have become an indispensable tool for the reconstruction process. Most recently, "propeller" perforator flaps allow each perforator vessels to become a flap donor site. Once the perforator of interest is identified by acoustic Doppler, the cutaneous or fascio-cutaneous island is designed and then customized according to the principle of "perforasome". So, the flap can be rotated such a propeller, up to 180°. Ideally the donor site is self-closing, otherwise it can be grafted at the same time. Through a skin necrosis secondary to a contrast medium extravasation of the cubital fossa in a 47-year-old man, we describe the use of propeller perforator flap based on a perforator of the radial collateral artery (RCAP). The perforator was identified preoperatively by acoustic Doppler then the flap was adapted bespoke to cover the loss of substance. Ultimately, the result was very satisfying. Well experienced for lower-extremity reconstruction, perforator-based propeller flap are still few reported for upper limb. It is likely that in the future, propeller flap supersede in many indication not only free flaps and locoregional flaps but also, leaving no room for uncertainties of the vascular network, the classic random flaps. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  13. [Surgical issues and outcomes in ischial pressure sores treatment].

    PubMed

    Voulliaume, D; Grecea, M; Viard, R; Brun, A; Comparin, J-P; Foyatier, J-L

    2011-12-01

    Ischiatic pressure sores are frequent in spinal cord injury patients, associated with bad prognosis and high recurrence rate. Many surgical techniques were described, including surgical debridement followed by pedicled flap coverage. We aim to propose a practical decision tree for primary or secondary ischial pressure sore treatment. Our series of 48 operated ischial sores with an average follow up of 4 years (range 2 to 8years) is analyzed and compared to previously published reports. Surgical techniques are discussed according to their specific indications. The optimal recurrence rate in published reports about pressure sore treatment is 20%; a rate inferior to 19% is found in our series, showing the equal importance of flap selection and postoperative care and education. Depending on each situation, various available flaps are described and compared: gluteus maximus flap, biceps femoris flap, gracilis flap, tensor fascia lata flap, fasciocutaneous thigh flaps, rectus femoris and vastus lateralis flap, rectus abdominis flap. Specific surgical indications for more extensive wounds are studied: resection arthroplasty of the hip, hip disarticulation, fillet flaps from the leg, microsurgery. Based upon our experience, a decision tree summarizes our proposition of flap selection, depending on the wound size and the patient background. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  14. Calf Perforator Flaps: A Freestyle Solution for Oral Cavity Reconstruction.

    PubMed

    Molina, Alexandra R; Citron, Isabelle; Chinaka, Fungayi; Cascarini, Luke; Townley, William A

    2017-02-01

    Reconstruction of oral cavity defects requires a thin, pliable flap for optimal functional results. Traditional flap choices are imperfect: the anterolateral thigh flap is excessively thick, whereas the radial forearm flap has a poor donor site. The authors therefore favor calf perforator flaps such as the medial sural artery perforator flap to provide thin tissue with an acceptable donor site. This two-part study aims to demonstrate their suitability for intraoral reconstruction. In the radiologic part of the study, the authors compared thigh and calf tissue thickness by examining lower limb computed tomographic scans of 100 legs. For their clinical study, they collected data prospectively on 20 cases of oral cavity reconstruction using calf perforator flaps. The mean thickness of the calf tissue envelope was significantly less than that of the thigh (8.4 mm compared with 17 mm) based on computed tomographic analysis. In the clinical study, a medial sural artery perforator was used in the majority of cases (17 of 20). The mean pedicle length was 10.2 cm and the mean time to raise a flap was 85 minutes. There were no flap losses. One patient was returned to the operating room for management of late hematoma and wound dehiscence. Calf perforator flaps provide ideal tissue for intraoral reconstruction and are significantly thinner than anterolateral thigh flaps. In addition to medial sural artery perforator flaps, the authors raised both sural and soleal artery perforator flaps in this series. Opportunistic use of the calf donor site allows the harvest of thin tissue with minimal donor-site morbidity. Therapeutic, IV.

  15. A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft.

    PubMed

    Lim, Hyoseob; Han, Dae Hee; Lee, Il Jae; Park, Myong Chul

    2014-03-01

    Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.

  16. The transverse musculocutaneous gracilis flap for breast reconstruction: guidelines for flap and patient selection.

    PubMed

    Schoeller, Thomas; Huemer, Georg M; Wechselberger, Gottfried

    2008-07-01

    The transverse musculocutaneous gracilis (TMG) flap has received little attention in the literature as a valuable alternative source of donor tissue in the setting of breast reconstruction. The authors give an in-depth review of their experience with breast reconstruction using the TMG flap. A retrospective review of 111 patients treated with a TMG flap for breast reconstruction in an immediate or a delayed setting between August of 2002 and July of 2007 was undertaken. Of these, 26 patients underwent bilateral reconstruction and 68 underwent unilateral reconstruction, and 17 patients underwent reconstruction unilaterally with a double TMG flap. Patient age ranged between 24 and 65 years (mean, 37 years). Twelve patients had to be taken back to the operating room because of flap-related problems and nine patients underwent successful revision microsurgically, resulting in three complete flap losses in a series of 111 patients with 154 transplanted TMG flaps. Partial flap loss was encountered in two patients, whereas fat tissue necrosis was managed conservatively in six patients. Donor-site morbidity was an advantage of this flap, with a concealed scar and minimal contour irregularities of the thigh, even in unilateral harvest. Complications included delayed wound healing (n = 10), hematoma (n = 5), and transient sensory deficit over the posterior thigh (n = 49). The TMG flap is more than an alternative to the deep inferior epigastric perforator (DIEP) flap in microsurgical breast reconstruction in selected patients. In certain indications, such as bilateral reconstructions, it possibly surpasses the DIEP flap because of a better concealed donor scar and easier harvest.

  17. Flow Modulation and Force Control of Flapping Wings

    DTIC Science & Technology

    2014-10-29

    evolution of which reflect the wing morphology and kinematics. While the near-wake vortex system directly reflects the action of the wing on the...at 8 different stroke positions, which demonstrate the evolution of the vortex wake structure. The contour plot of Z vorticity at X-Y plane (Z...20 Figure 14. Smoke patterns showing the evolution of the flow structure in an

  18. Experimental Study on Charging Process in the COREX Melter Gasifier

    NASA Astrophysics Data System (ADS)

    Luo, Zhiguo; You, Yang; Li, Haifeng; Zhou, Heng; Zou, Zongshu

    2018-04-01

    Burden distribution plays an important role in achieving high stability and energy efficiency in the COREX melter gasifier. In this work, a 1/7.5 scale experimental apparatus is established to investigate the burden distribution under the independent and mixed charging conditions. The effects of GIMBAL distributor angle, rotational speed, DRI-flap angle, and charging pattern on these charging conditions are investigated. The results show that the non-uniform distribution of pellet in circumferential direction is intrinsic to the discharge system due to the shape of the DRI flap. The charging pattern has a significant impact on the ore-to-coal volume ratio and bed voidage. The ore-to-coal volume ratio reaches the peak at 550 to 650 mm, indicating that the reduction burden near the wall is heavier than that in the center. The voidage in the middle region is smaller than that of the center and near-wall region. The results also reveal the size segregation along the radial direction of the burden pile. The smaller particles tend to accumulate in the center while the larger ones segregate more near the wall. The findings obtained from experiments should be helpful for the efficient operation of the COREX melter gasifier.

  19. Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease.

    PubMed

    Rodríguez-Palomares, José Fernando; Dux-Santoy, Lydia; Guala, Andrea; Kale, Raquel; Maldonado, Giuliana; Teixidó-Turà, Gisela; Galian, Laura; Huguet, Marina; Valente, Filipa; Gutiérrez, Laura; González-Alujas, Teresa; Johnson, Kevin M; Wieben, Oliver; García-Dorado, David; Evangelista, Arturo

    2018-04-26

    In patients with bicuspid valve (BAV), ascending aorta (AAo) dilatation may be caused by altered flow patterns and wall shear stress (WSS). These differences may explain different aortic dilatation morphotypes. Using 4D-flow cardiovascular magnetic resonance (CMR), we aimed to analyze differences in flow patterns and regional axial and circumferential WSS maps between BAV phenotypes and their correlation with ascending aorta dilatation morphotype. One hundred and one BAV patients (aortic diameter ≤ 45 mm, no severe valvular disease) and 20 healthy subjects were studied by 4D-flow CMR. Peak velocity, flow jet angle, flow displacement, in-plane rotational flow (IRF) and systolic flow reversal ratio (SFRR) were assessed at different levels of the AAo. Peak-systolic axial and circumferential regional WSS maps were also estimated. Unadjusted and multivariable adjusted linear regression analyses were used to identify independent correlates of aortic root or ascending dilatation. Age, sex, valve morphotype, body surface area, flow derived variables and WSS components were included in the multivariable models. The AAo was non-dilated in 24 BAV patients and dilated in 77 (root morphotype in 11 and ascending in 66). BAV phenotype was right-left (RL-) in 78 patients and right-non-coronary (RN-) in 23. Both BAV phenotypes presented different outflow jet direction and velocity profiles that matched the location of maximum systolic axial WSS. RL-BAV velocity profiles and maximum axial WSS were homogeneously distributed right-anteriorly, however, RN-BAV showed higher variable profiles with a main proximal-posterior distribution shifting anteriorly at mid-distal AAo. Compared to controls, BAV patients presented similar WSS magnitude at proximal, mid and distal AAo (p = 0.764, 0.516 and 0.053, respectively) but lower axial and higher circumferential WSS components (p < 0.001 for both, at all aortic levels). Among BAV patients, RN-BAV presented higher IRF at all levels (p = 0.024 proximal, 0.046 mid and 0.002 distal AAo) and higher circumferential WSS at mid and distal AAo (p = 0.038 and 0.046, respectively) than RL-BAV. However, axial WSS was higher in RL-BAV compared to RN-BAV at proximal and mid AAo (p = 0.046, 0.019, respectively). Displacement and axial WSS were independently associated with the root-morphotype, and circumferential WSS and SFRR with the ascending-morphotype. Different BAV-phenotypes present different flow patterns with an anterior distribution in RL-BAV, whereas, RN-BAV patients present a predominant posterior outflow jet at the sinotubular junction that shifts to anterior or right anterior in mid and distal AAo. Thus, RL-BAV patients present a higher axial WSS at the aortic root while RN-BAV present a higher circumferential WSS in mid and distal AAo. These results may explain different AAo dilatation morphotypes in the BAV population.

  20. Tidal Triggering and Statistical Patterns of Microseismicity at Axial Volcano on the Juan de Fuca Ridge

    NASA Astrophysics Data System (ADS)

    Bohnenstiehl, D. R.; Dziak, R. P.; Caplan-Auerbach, J.; Haxel, J. H.; Mann, M. E.; Pennington, C.; Weis, J.; Womack, N.; Levy, S.

    2015-12-01

    Tidal stress changes are known to modulate the timing of microearthquakes within many mid-ocean ridge volcanic systems. At Axial Volcano, located on the Juan de Fuca Ridge, earthquakes occur preferentially when volumetric extension peaks near times of low ocean tide. Autonomous ocean-bottom hydrophone (OBH, 2007-2011) and cabled ocean bottom seismometer (OBS, Nov. 2014-) data are used to quantify the strength of tidal triggering in time periods before the April 2011 and April 2015 eruptions at Axial Volcano. The mean percent excess at times of low ocean-tide is ~14% (16% std) in the four years prior to the 2011 eruption and ~18% (17% std) in the five months prior to the 2015 eruption. The sensitivity of earthquakes to tidal stress does not evolve systematically prior to either eruption; however, this pattern is disturbed by much larger stress changes associated with the onset of dike intrusion. Following dike injection and eruption, seismicity rates drop sharply. As seismicity rates continue to rise in the months following the 2015 eruption, real-time data available from the cabled OBS network will be used quantify temporal patterns in microearthquake activity as dike induced stresses are relaxed and the magma chamber inflates.

  1. Patterns of motor activity in the isolated nerve cord of the octopus arm.

    PubMed

    Gutfreund, Yoram; Matzner, Henry; Flash, Tamar; Hochner, Binyamin

    2006-12-01

    The extremely flexible octopus arm provides a unique opportunity for studying movement control in a highly redundant motor system. We describe a novel preparation that allows analysis of the peripheral nervous system of the octopus arm and its interaction with the muscular and mechanosensory elements of the arm's intrinsic muscular system. First we examined the synaptic responses in muscle fibers to identify the motor pathways from the axial nerve cord of the arm to the surrounding musculature. We show that the motor axons project to the muscles via nerve roots originating laterally from the arm nerve cord. The motor field of each nerve is limited to the region where the nerve enters the arm musculature. The same roots also carry afferent mechanosensory information from the intrinsic muscle to the axial nerve cord. Next, we characterized the pattern of activity generated in the dorsal roots by electrically stimulating the axial nerve cord. The evoked activity, although far reaching and long lasting, cannot alone account for the arm extension movements generated by similar electrical stimulation. The mismatch between patterns of activity in the isolated cord and in an intact arm may stem from the involvement of mechanosensory feedback in natural arm extension.

  2. 14 CFR 23.697 - Wing flap controls.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Wing flap controls. 23.697 Section 23.697... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap...

  3. 14 CFR 23.697 - Wing flap controls.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Wing flap controls. 23.697 Section 23.697...

  4. 14 CFR 23.697 - Wing flap controls.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Wing flap controls. 23.697 Section 23.697...

  5. 14 CFR 23.697 - Wing flap controls.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Wing flap controls. 23.697 Section 23.697...

  6. 14 CFR 23.697 - Wing flap controls.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Design and Construction Control Systems § 23.697 Wing flap controls. (a) Each wing flap control must be designed so that, when the flap... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Wing flap controls. 23.697 Section 23.697...

  7. Glove box shield

    DOEpatents

    Brackenbush, Larry W.; Hoenes, Glenn R.

    1981-01-01

    According to the present invention, a shield for a glove box housing radioactive material is comprised of spaced apart clamping members which maintain three overlapping flaps in place therebetween. There is a central flap and two side flaps, the side flaps overlapping at the interior edges thereof and the central flap extending past the intersection of the side flaps in order to insure that the shield is always closed when the user withdraws his hand from the glove box. Lead loaded neoprene rubber is the preferred material for the three flaps, the extent of lead loading depending upon the radiation levels within the glove box.

  8. Biomimetic Beetle-Inspired Flapping Air Vehicle Actuated by Ionic Polymer-Metal Composite Actuator.

    PubMed

    Zhao, Yang; Xu, Di; Sheng, Jiazheng; Meng, Qinglong; Wu, Dezhi; Wang, Lingyun; Xiao, Jingjing; Lv, Wenlong; Chen, Qinnan; Sun, Daoheng

    2018-01-01

    During the last decades, the ionic polymer-metal composite (IPMC) received much attention because of its potential capabilities, such as large displacement and flexible bending actuation. In this paper, a biomimetic flapping air vehicle was proposed by combining the superiority of ionic polymer metal composite with the bionic beetle flapping principle. The blocking force was compared between casted IPMC and IPMC. The flapping state of the wing was investigated and the maximum displacement and flapping angle were measured. The flapping displacement under different voltage and frequency was tested. The flapping displacement of the wing and the support reaction force were measured under different frequency by experiments. The experimental results indicate that the high voltage and low frequency would get large flapping displacement.

  9. Piloted simulation study of two tilt-wing control concepts

    NASA Technical Reports Server (NTRS)

    Birckelbaw, Lourdes G.; Corliss, Lloyd D.

    1994-01-01

    A two-phase piloted simulation study was conducted to investigate alternative wing and flap controls for tilt-wing aircraft. The initial phase of the study compared the flying qualities of both a conventional (programmed) flap and an innovative geared flap. The second phase of the study introduced an alternate method of pilot control for the geared flap and further studied the flying qualities of the programmed flap, and two geared flap configurations. In general, the pilot rating showed little variation between the programmed flap and the geared flap control concepts. Some differences between the two concepts were noticed and are discussed in this paper. The addition of pitch attitude stabilization in the second phase of the study greatly enhanced the aircraft flying qualities. This paper describes the simulated tilt-wing aircraft and the flap control concepts and presents the results of both phases of the simulation study.

  10. The unique and valuable soft tissue free flap in head and neck reconstruction: Lateral arm.

    PubMed

    Kang, Stephen Y; Eskander, Antoine; Patel, Krupal; Teknos, Theodoros N; Old, Matthew O

    2018-07-01

    While the lateral arm free flap has been well described, there is a relative paucity in its use compared to other free flaps and regional flaps. The lateral arm free flap is a unique soft tissue free flap that provides several reconstructive advantages in head and neck reconstruction: excellent contour and color match to facial skin, well compartmentalized fat, donor nerves for nerve grafting, and the ability to two-team harvest and close the donor site without a skin graft. A detailed anatomic and harvest technique is described, along with indications and advantages of using lateral free flap for head and neck reconstruction. A scoping literature review was also conducted to tabulate indications, overall success and complications of the flap. The lateral arm flap is a primary option for defects requiring soft tissue reconstruction in the head and neck. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Lower Extremity Free Flaps for Breast Reconstruction.

    PubMed

    Dayan, Joseph H; Allen, Robert J

    2017-11-01

    Thigh-based flaps are typically a secondary option for breast reconstruction because of concerns regarding limited tissue volume and donor-site morbidity. In recent years, there have been a number of new techniques and insights that have resulted in greater flexibility and improved outcomes. This article reviews lessons learned from a large collective experience using the following 4 flaps: transverse upper gracilis also known as transverse myocutaneous gracilis, diagonal upper gracilis, profunda artery perforator, and lateral thigh perforator flaps. Flap selection considerations include the patient's fat distribution and skin laxity, perforator anatomy, and scar location. Pearls to minimize donor-site morbidity include avoiding major lymphatic collectors in the femoral triangle and along the greater saphenous vein and respecting the limits of flap dimension to reduce wound healing complications and distal ischemia. Limited flap volume may be addressed with stacking another flap from the contralateral thigh or primary fat grafting as opposed to overaggressive flap harvest from a single thigh. A detailed review of the benefits and disadvantages of each flap and strategies to improve results is discussed. With careful planning and selection, thigh-based flaps can provide a reliable option patients desiring autologous breast reconstruction.

  12. A performance application study of a jet-flap helicopter rotor

    NASA Technical Reports Server (NTRS)

    Sullivan, R. J.; Laforge, S.; Holchin, B. W.

    1972-01-01

    A performance study was made of the application of a jet-flap to a reaction-drive rotor for a heavy-lift helicopter mission and for a high-speed-helicopter maneuverability (200 knots, 2g) mission. The results of the study are as follows: As a result of the increase in maximum airfoil lift coefficient achieved by the jet-flap, rotor solidity is reduced with the jet-flap to approximately 59% of a nonjet-flap rotor. As a result of the saving in rotor solidity, and hence in rotor weight, the jet-flap configuration had a 21% higher productivity than a nonjet-flap configuration. Of the three propulsion systems studied utilizing a jet-flap (hot cycle, warm cycle, cold cycle) the hot cycle gave the largest increase in productivity. The 200 knot 2g mission is performed best with a warm cycle propulsion system. The jet-flap permits designing for a rotor blade loading coefficient C sub T/sigma = .170 at 2g without encountering blade stall. The jet-flap rotor permits a 200 knot 2g maneuver without suffering the penalty of an unreasonable rotor solidity that would be required by a nonjet-flap rotor.

  13. [A reverse vascular autograft finger island flap. A review of 15 cases and of the literature].

    PubMed

    Adani, R; Marcuzzi, A; Busa, R; Pancaldi, G; Bathia, A; Caroli, A

    1995-01-01

    The authors discuss the indications for homodigital island flap with a reverse vascular pedicle. This flap is based on the anastomoses between the radial and ulnar digital arteries. These anastomotic branches lie between the posterior wall of the tendon sheath and the periosteum to form an arch and are named the "digitopalmar arches". The vascularization of the reverse homodigital island flap is derived by using the middle transverse palmar arch. This flap was performed successfully in 14 patients involving 15 fingers to resurface amputation of the distal phalanx. In 6 cases the flap was used as an "artery" flap, and in 9 cases as a "sensitive" homodigital island flap. The pedicle in these cases was neurovascular also containing the digital nerve. The sensitivity of the flap was obtained by neurorraphy between the transposed digital nerve of the flap and the receiving digital nerve of the recipient finger. This technique achieves cover of the tactile pad in one operative stage and provides well vascularized skin allowing early mobilization. Sensation of the flap can be restored rapidly when neurorraphy of the transposed digital nerve is performed.

  14. Reconstruction of pressure sores with perforator-based propeller flaps.

    PubMed

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  15. Low-Speed Wind-Tunnel Investigation of Blowing Boundary-Layer Control on Leading- and Trailing-Edge Flaps of a Large-Scale, Low-Aspect-Ratio, 45 Swept-wing Airplane Configuration

    NASA Technical Reports Server (NTRS)

    Maki, Ralph L.

    1959-01-01

    Blowing boundary-layer control was applied to the leading- and trailing-edge flaps of a 45 deg sweptback-wing complete model in a full-scale low-speed wind-tunnel study. The principal purpose of the study was to determine the effects of leading-edge flap deflection and boundary-layer control on maximum lift and longitudinal stability. Leading-edge flap deflection alone was sufficient to maintain static longitudinal stability without trailing-edge flaps. However, leading-edge flap blowing was required to maintain longitudinal stability by delaying leading-edge flow separation when trailing-edge flaps were deflected either with or without blowing. Partial-span leading-edge flaps deflected 60 deg with moderate blowing gave the major increase in maximum lift, although higher deflection and additional blowing gave some further increase. Inboard of 0.4 semispan leading-edge flap deflection could be reduced to 40 deg and/or blowing could be omitted with only small loss in maximum lift. Trailing-edge flap lift increments were increased by boundary-layer control for deflections greater than 45 deg. Maximum lift was not increased with deflected trailing-edge flaps with blowing.

  16. The effect of partial-span split flaps on the aerodynamic characteristics of a Clark Y wing

    NASA Technical Reports Server (NTRS)

    Wenzinger, Carl J

    1933-01-01

    Aerodynamic force tests were made in the N.A.C.A. 7 by 10 foot wind tunnel on a model Clark Y wing with a 20 percent chord split flap deflected 60 degrees downward. The tests were made to determine the effect of partial-span split flaps, located at various positions along the wing span on the aerodynamic characteristics of the wing-and-flap combination. The different lengths and locations of the flaps were obtained by cutting off portions of a full-span flap, first from the tips and then from the center. The results are given in the form of curves of lift, drag, and center of pressure. They show that with partial-span split flaps both the lift and drag are less than with full-span flaps; that the lift for a given length of flap is somewhat greater when the partial span is located at the center of the wing than when it is located at the tip portion, and that the drag for a given length of flap is the same regardless of the location over the flap with respect to the wing span.

  17. Effect of Krueger nose flaps on the experimental force and moment characteristics of an oblique wing

    NASA Technical Reports Server (NTRS)

    Hopkins, E. J.; Lovette, G. H.

    1976-01-01

    Experimental force and moment data are presented for an oblique wing mounted on a body of revolution and equipped with Krueger type nose flaps. The effectiveness of these flaps in making the moment curves more linear by controlling the flow separation on the downstream wing panel at high lift coefficients was determined. The investigation of the effects of the Krueger flaps covered two cases: (1) use of the flaps on the downstream wing panel only and (2) use of the flaps on both wing panels. For part of the tests, the Krueger flaps were mounted on nose flaps that were drooped either 5 deg or 10 deg. The wing was elliptical in planform, had an aspect ratio of 6.0 (based on the unswept span) and was tested at sweep angles of 0, 45 deg, and 50 deg. The Mach-number range covered was from 0.25 to 0.95. It was found that the most effective arrangement of the Krueger flaps for making the pitching-, rolling-, and yawing-moment curves more linear at high lift coefficients was having the Krueger flaps mounted on the nose flaps drooped 5 deg and only on the downstream wing panel.

  18. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    PubMed

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  19. Circular and longitudinal muscles shortening indicates sliding patterns during peristalsis and transient lower esophageal sphincter relaxation

    PubMed Central

    Patel, Nirali; Jiang, Yanfen; Mittal, Ravinder K.; Kim, Tae Ho; Ledgerwood, Melissa

    2015-01-01

    Esophageal axial shortening is caused by longitudinal muscle (LM) contraction, but circular muscle (CM) may also contribute to axial shortening because of its spiral morphology. The goal of our study was to show patterns of contraction of CM and LM layers during peristalsis and transient lower esophageal sphincter (LES) relaxation (TLESR). In rats, esophageal and LES morphology was assessed by histology and immunohistochemistry, and function with the use of piezo-electric crystals and manometry. Electrical stimulation of the vagus nerve was used to induce esophageal contractions. In 18 healthy subjects, manometry and high frequency intraluminal ultrasound imaging during swallow-induced esophageal contractions and TLESR were evaluated. CM and LM thicknesses were measured (40 swallows and 30 TLESRs) as markers of axial shortening, before and at peak contraction, as well as during TLESRs. Animal studies revealed muscular connections between the LM and CM layers of the LES but not in the esophagus. During vagal stimulated esophageal contraction there was relative movement between the LM and CM. Human studies show that LM-to-CM (LM/CM) thickness ratio at baseline was 1. At the peak of swallow-induced contraction LM/CM ratio decreased significantly (<1), whereas the reverse was the case during TLESR (>2). The pattern of contraction of CM and LM suggests sliding of the two muscles. Furthermore, the sliding patterns are in the opposite direction during peristalsis and TLESR. PMID:26045610

  20. Comparative study of 2 commissural dorsal flap techniques for the treatment of congenital syndactyly.

    PubMed

    Mallet, Cindy; Ilharreborde, Brice; Jehanno, Pascal; Litzelmann, Estelle; Valenti, Philippe; Mazda, Keyvan; Penneçot, Georges-François; Fitoussi, Franck

    2013-03-01

    Many commissural reconstruction techniques have been described for the treatment of syndactyly. This study is the first to compare long-term results of 2 commissural dorsal flap procedures (T-flap and omega-flap). Fifty-nine web-spaces in 39 patients, operated on between 1991 and 2008, were retrospectively analyzed. Thirty-six T-flap and 23 omega-flap procedures were performed using full-thickness skin graft in every case for digital resurfacing. Factors that could affect the long-term outcome were collected, including development of web-creep, clinodactyly, and flexion contracture. Patients were reviewed with a mean follow-up of 5 years and 8 months. Preoperative complexity of syndactyly influenced the development of clinodactyly and flexion contracture. Among the patients who developed clinodactyly, 96% had surgery for complex syndactyly. No difference was found between the 2 flap methods concerning digital deformation and mobility. However, web-creep occurred more frequently after T-flap than after omega-flap procedures (17% vs. 5%). The combination of either dorsal commissural T-flaps or omega-flaps with full-thickness graft to resurface digits is a reliable technique for the treatment of syndactyly with satisfactory functional and cosmetic results. Long-term results are not influenced by the type of flap. Nevertheless, the omega-flap technique, using 2 triangular lateral-palmar flaps, avoids use of skin graft to cover lateral-palmar aspects of the new commissure, consequently reducing the incidence of web-creep. In cases of syndactyly, the primary prognostic factor is whether the patient has simple or complex syndactyly. In complex syndactyly, the risk of long-term unfavorable results is higher. When complex complicated syndactyly is involved, postoperative complication rates increase. Level III.

  1. The effect of topical minoxidil pretreatment on nonsurgical delay of rat cutaneous flaps: further studies.

    PubMed

    Gümüş, Nazım; Odemiş, Yusuf; Tuncer, Ersin; Yılmaz, Sarper

    2013-08-01

    The purpose of this study was to determine the effectiveness of topically applied minoxidil in the pharmacological delay phenomenon and to demonstrate the comparable microscopic and macroscopic changes between minoxidil-pretreated flaps and surgically delayed flaps. A modified version of the McFarlane flap was used. Group 1 rats, in which a caudally based dorsal skin flap was raised and sutured back, were the control group. In group II, minoxidil solution was spread over the marked skin flap area for 7 days. On the 7th day, a caudally based dorsal skin flap was elevated and then sutured back. Group III rats underwent a surgical delay procedure alone. On the 7th day after flap elevation, evaluation was done by histologic examination and calculation of the flap survival areas in all groups. The lowest flap survival rate appeared in group I and was statistically different from groups II and III. The mean surviving skin flap area in the minoxidil-pretreated group was significantly larger than that in the control group. After histologic evaluation, moderate angiogenesis was also detected in group II. We also found that surgical delay significantly reduced flap necrosis when compared to the minoxidil pretreatment group. According to our study, minoxidil may be considered an effective vasoactive agent for the stimulation of angiogenesis in rat cutaneous flaps and capable of achieving pharmacological delay and increasing flap survival. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  2. The myocutaneous trapezius flap revisited: a treatment algorithm for optimal surgical outcomes based on 43 flap reconstructions.

    PubMed

    Can, Anil; Orgill, Dennis P; Dietmar Ulrich, J O; Mureau, Marc A M

    2014-12-01

    Because the vascular anatomy of the trapezius flap is highly variable, choosing the most appropriate flap type and design is essential to optimize outcomes and minimize postoperative complications. The aim of this study was to develop a surgical treatment algorithm for trapezius flap transfers. The medical files of all consecutive patients with a myocutaneous trapezius flap reconstruction of the head, neck, and upper back area treated at three different university medical centers between July 2001 and November 2012 were reviewed. There were 43 consecutive flaps performed in 38 patients with a mean follow-up time of 15 months (range, 1-48 months). Eleven patients had a mentosternal burn scar contracture (12 flaps), 12 patients (13 flaps) presented with cancer, and 15 patients (18 flaps) were suffering from chronic wounds due to failed previous reconstruction (n = 6), osteoradionecrosis (n = 1), chronic infection (n = 3), bronchopleural fistula (n = 3), and pressure sores (n = 2). The mean defect size was 152 cm(2). Sixteen flaps were based on the superficial cervical artery (SCA; type 2), 16 were based on the dorsal scapular artery (DSA; type 3), one was based on the intercostal arteries (type 4), and 10 flaps were based on both the DSA and SCA. Recipient-site complications requiring reoperation occurred in 16.3%, including one total flap failure (2.6%). The trapezius myocutaneous flap is a valuable option to reconstruct various head and neck and upper back defects. Based on our data, a surgical treatment algorithm was developed in an attempt to reduce variation in care and improve clinical outcomes. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. [Contribution of the scrotal flap for the coverage of ischial and perineal pressure ulcers].

    PubMed

    Vantomme, M; Viard, R; Aimard, R; Vincent, P-L; Comparin, J-P; Voulliaume, D

    2018-04-11

    The ischiatric pressure sore is a common pathology in rehabilitated spinal cord injured people, despite careful prevention. Medical treatment by discharge and directed healing is not always sufficient and surgery using local musculocutaneous flaps is often essential. Unfortunately, recidivism is frequent and the availability of local flaps is limited. The scrotal flap is an excellent complement to classic flaps, gluteal flaps or hamstrings. It can be used alone or in addition to another musculocutaneous flap, in first or second intention. The scrotal flap is a musculocutaneous flap, using the Dartos, the platys muscle of the scrotum. It is richly vascularized, extensible and resistant. Its great plasticity makes it adaptable to any form of loss of substance, with an arc of rotation that can reach the anal margin. It can also be desepidermized and buried to fill a deep defect. Ten cases of scrotal flaps and their different indications are reviewed: some are used in first intention, others in addition to musculocutaneous flaps. The removal of a scrotal flap is fast and extremely easy. The simple closure of the donor site allows the sampling of half of the scrotum due to the great local laxity. The scrotal flaps achieved quickly healed, as well as the donor sites. Only one recurrence was observed after an inappropriate treatment of underlying osteitis. No complications have occurred. The scrotal musculocutaneous flap, reliable, resistant, quick and easy to remove is an excellent means of coverage of the perineal region. It can be used for the treatment of any loss of perineal substance in humans, but remains particularly useful for the treatment of ischial or perineal pressure sores. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  4. Defining the Role of Free Flaps in Partial Breast Reconstruction.

    PubMed

    Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H

    2018-03-01

     Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer.  A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction.  There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap.  Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Performance analysis of axial flow pump on gap changing between impeller and guide vane

    NASA Astrophysics Data System (ADS)

    Wang, W. J.; Liang, Q. H.; Wang, Y.; Yang, Y.; Yin, G.; Shi, X. X.

    2013-12-01

    In order to study the influence on gap changing of the static and dynamic components in axial flow pump, the axial flow pump model (TJ04-ZL-06) that used in the eastern of south-to-north water diversion project was selected. Steady turbulence field with different gaps was simulated by standard κ-ε turbulence model and double-time stepping methods. Information on the pressure distribution and velocity distribution of impeller surfaces were obtained. Then, calculated results were compared with the test results and analyzed. The results show that the performance of pump is not sensitive with the axial gap width under design conditions and the large flow rate condition. With increasing gap width, it will be improved in low flow rate condition. The attack angle of impeller inlet in small flow rate condition become small and the flow separation phenomenon can be observed in this condition. The axial velocity distribution of impeller outlet is nonlinear and to increase the axial gap is to improve the flow pattern near the hub effectively. The trend of calculating results is identical with test. It will play a guiding role to the axial pump operation and design in south-to-north water diversion project.

  6. In situ monitoring of surgical flap viability using THz imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bajwa, Neha; Sung, Shijun; Grundfest, Warren; Taylor, Zachary

    2016-03-01

    This paper explores the utility of reflective THz imaging to assess the viability of surgical flaps. Flap surgery is a technique where tissue is harvested from a donor site and moved to a recipient while keeping the blood supply intact. This technique is common in head and neck tumor resection surgery where the reconstruction of complex and sensitive anatomic structures is routine following the resection of large and/or invasive tumors. Successful flap surgery results in tissue that is sufficiently perfused with both blood and extracellular water. If insufficient fluid levels are maintained, the flap tissue becomes necrotic and must be excised immediately to prevent infection developing and spreading to the surrounding areas. The goal of this work is to investigate the hydration of surgical flaps and correlate image features to successful graft outcomes. Advancement flaps were created on the abdomens of rat models. One rat model was labeled control and care was taken to ensure a successful flap outcome. The flap on the second rat was compromised with restricted blood flow and allowed to fail. The flaps of both rats were imaged once a day over the course of a week at which point the compromised flap had begun to show signs of necrosis. Significant differences in tissue water content were observed between rats over the experimental period. The results suggest that THz imaging may enable early assessment of flap viability.

  7. Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.

    PubMed

    Wolf, Alvit; Hod, Yair; Buckman, Gila; Stein, Nili; Geyer, Orna

    2016-04-01

    To compare the efficacy of an autoscleral free-flap graft versus an autoscleral rotational flap graft in Ahmed glaucoma valve (AGV) surgery. Medical records (2005 to 2012) of 51 consecutive patients (51 eyes) who underwent AGV surgery with the use of either an autoscleral free-flap graft or an autoscleral rotational flap graft to cover the external tube at the limbus were retrieved for review. The main outcome measure was the incidence of tube exposure associated with each surgical approach. Twenty-seven consecutive patients (27 eyes) received a free-flap graft and 24 consecutive patients (24 eyes) received a rotational flap graft. The mean follow-up time was 55.6 ± 18.3 months for the former and 24.2± 5 .0 months for the latter (P<0.0001). Two patients in the free-flap group (8.9%) developed tube exposure at 24 and 55 months postoperatively compared with none of the patients in the rotational flap group. Graft thinning without evidence of conjunctival erosion was observed in 15 patients (55%) in the free-flap group and in 7 patients (29.1%) in the rotational flap group. The use of an autoscleral rotational flap graft is an efficacious technique for primary tube patch grafting in routine AGV surgery, and yielded better results than an autoscleral free-flap graft. Its main advantages over donor graft material are availability and lower cost.

  8. Effect of marking pens on femtosecond laser-assisted flap creation.

    PubMed

    Ide, Takeshi; Kymionis, George D; Abbey, Ashkan M; Yoo, Sonia H; Culbertson, William W; O'Brien, Terrence P

    2009-06-01

    To compare the ease of the flap lift after central corneal marking with 2 types of marking pens after femtosecond laser-assisted flap creation in laser in situ keratomileusis. Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA. Porcine eyes were prepared for flap creation with a femtosecond laser (IntraLase). The eyes were assigned to 1 of 4 groups. After the femtosecond laser treatment, the difficulty of flap lifting the 4 groups was compared. Twelve porcine eyes, 3 in each group, were evaluated. In the 2 groups in which an oil-based pen was used, the corneal flap could not be lifted. In the 2 groups in which a water-based pen was used, the corneal flap was easily lifted. Oil-based ink may reduce the ability of the femtosecond laser to penetrate the cornea. The resultant corneal flap may require aggressive manipulation to be lifted. When used to mark the center of the cornea before flap creation, water-based ink provided greater ease of corneal flap lifting than oil-based ink. Because the marking is located over the center of the pupil, any alteration of the cornea in this area from aggressive flap lifting may result in substantial visual loss. Therefore, the use of an oil-based ink to mark the central cornea must be avoided to prevent traumatic irregularities of the flap stroma.

  9. Double transverse myocutaneous gracilis free flaps for unilateral breast reconstruction.

    PubMed

    Werdin, Frank; Haug, Daniel M; Amr, Amro; Schoeller, Thomas

    2016-10-01

    In cases were the deep inferior epigastric perforator flap (DIEP flap) is not available and unilateral transverse myocutaneous gracilis flap (TMG flap) is not sufficient for breast reconstruction, we perform double TMG flaps as a reconstructive method. In this report, we present our results of the use of double TMG free-flap-transfer for unilateral breast reconstruction. Between August 2004 and June 2012 we performed 58 TMG flaps in 29 patients for unilateral breast reconstruction. Patient data were analyzed and operative outcome (operation time, complication rate and aesthetic results) were investigated. Aesthetic outcome was evaluated retrospectively via photo documentation by an independent plastic surgeon. The results were classified in;unsatisfactory, satisfactory, good and very good. The average operating time was 6 hours 55 minutes (295 - 650 minutes). Of 58 TMG flaps, 57 (98.3%) were successful. Thrombosis occurred in seven (12%) cases (1 arterial, 6 venous). Flap salvage was successful in six cases and flap failure occurred in one (1.7%) case. The results of 25 patients were graded as good and very good. Three patients showed satisfying and one patient unsatisfying results. Double TMG flaps in unilateral breast reconstruction could lead to good operative results. This method further expands the range of options with autologous tissue in reconstructive breast surgery. © 2015 Wiley Periodicals, Inc. Microsurgery 36:539-545, 2016. © 2015 Wiley Periodicals, Inc.

  10. Optimal placement of trailing-edge flaps for helicopter vibration reduction using response surface methods

    NASA Astrophysics Data System (ADS)

    Viswamurthy, S. R.; Ganguli, Ranjan

    2007-03-01

    This study aims to determine optimal locations of dual trailing-edge flaps to achieve minimum hub vibration levels in a helicopter, while incurring low penalty in terms of required trailing-edge flap control power. An aeroelastic analysis based on finite elements in space and time is used in conjunction with an optimal control algorithm to determine the flap time history for vibration minimization. The reduced hub vibration levels and required flap control power (due to flap motion) are the two objectives considered in this study and the flap locations along the blade are the design variables. It is found that second order polynomial response surfaces based on the central composite design of the theory of design of experiments describe both objectives adequately. Numerical studies for a four-bladed hingeless rotor show that both objectives are more sensitive to outboard flap location compared to the inboard flap location by an order of magnitude. Optimization results show a disjoint Pareto surface between the two objectives. Two interesting design points are obtained. The first design gives 77 percent vibration reduction from baseline conditions (no flap motion) with a 7 percent increase in flap power compared to the initial design. The second design yields 70 percent reduction in hub vibration with a 27 percent reduction in flap power from the initial design.

  11. Instep island flaps.

    PubMed

    Reading, G

    1984-12-01

    The instep island flap is safe and useful. It is based on branches of the posterior tibial artery and can be a musculocutaneous or a direct fasciocutaneous island flap. Sensory branches of the digital nerves may be transposed with the flap. There is a wide arc of transposition and the flap has survived even in very difficult circumstances.

  12. Comparative study of functional and aesthetically outcomes of reverse digital artery and reverse dorsal homodigital island flaps for fingertip repair.

    PubMed

    Chen, Q Z; Sun, Y C; Chen, J; Kong, J; Gong, Y P; Mao, T

    2015-11-01

    This retrospective study was designed to compare functional and cosmetic outcomes of the reverse digital artery island flap and reverse dorsal homodigital island flap in fingertip repair. A total of 23 patients were followed for 24 to 30 months. The reverse digital artery island flap was used in 12 patients, and reverse dorsal homodigital island flap in another 11 patients. Flap sensibility was assessed using the Semmes-Weinstein monofilament test and static 2-point discrimination test. Patient satisfaction, active motion of the finger joints, complications and cold intolerance were evaluated. The static 2-point discrimination and Michigan Hand Outcomes Questionnaire (appearance) of the fingers treated with a reverse digital artery flap were significantly better than those with a reverse dorsal homodigital flap. The static 2-point discrimination of the skin-grafted donor sides after dorsal homodigital flap were poorer than that in the contralateral finger. No significant differences were found between the two flaps for pressure or touch sensibility, active ranges of digital motion, complications and cold intolerance. III. © The Author(s) 2015.

  13. Dorsal Intercostal Artery Perforator Propeller Flaps: A Reliable Option in Reconstruction of Large Meningomyelocele Defects.

    PubMed

    Basterzi, Yavuz; Tenekeci, Goktekin

    2016-04-01

    Several options have been reported for the reconstruction of myelomeningocele defects. In this article, we present our experience on soft tissue reconstruction of myelomeningocele defects by using island propeller dorsal intercostal artery perforator (DIAP) flaps. Between January 2008 and February 2014, all newborns with large myelomeningocele defects (13 newborns) were reconstructed with island propeller DIAP flaps. All flaps survived completely. In 8 patients out of 13, venous insufficiency was observed which then resolved spontaneously. Flap donor sites were closed primarily. Myelomeningocele defects with a diameter larger than 5 cm require reconstruction with flaps. To mobilize a well-vascularized tissue over the defect without tension in which the suture lines will not overlap over the midline where the dura is repaired and over the meninges is one of the goals of reconstruction for such defects. Perforator propeller flaps enable us to reach those goals. Use of perforator flaps provides 2 important advantages, namely, more predictability and also more freedom in mobilizing flaps toward the defect. This study proves the reliability of DIAP propeller flaps in the reconstruction of myelomeningocele defects.

  14. Biochemical analyses indicate that binding and cleavage specificities define the ordered processing of human Okazaki fragments by Dna2 and FEN1.

    PubMed

    Gloor, Jason W; Balakrishnan, Lata; Campbell, Judith L; Bambara, Robert A

    2012-08-01

    In eukaryotic Okazaki fragment processing, the RNA primer is displaced into a single-stranded flap prior to removal. Evidence suggests that some flaps become long before they are cleaved, and that this cleavage involves the sequential action of two nucleases. Strand displacement characteristics of the polymerase show that a short gap precedes the flap during synthesis. Using biochemical techniques, binding and cleavage assays presented here indicate that when the flap is ∼ 30 nt long the nuclease Dna2 can bind with high affinity to the flap and downstream double strand and begin cleavage. When the polymerase idles or dissociates the Dna2 can reorient for additional contacts with the upstream primer region, allowing the nuclease to remain stably bound as the flap is further shortened. The DNA can then equilibrate to a double flap that can bind Dna2 and flap endonuclease (FEN1) simultaneously. When Dna2 shortens the flap even more, FEN1 can displace the Dna2 and cleave at the flap base to make a nick for ligation.

  15. [Modified pectoralis major myocutaneous flap in reconstruction of head and neck defects].

    PubMed

    Chen, Jie; Huang, Wenxiao; Li, Zan; Zhou, Xiao; Yu, Jianjun; Bao, Ronghua; Zhang, Hailin; Ling, Hang

    2015-05-01

    To report the experience of use of modified pectoralis major myocutaneous (PMMC) flaps in reconstruction of head and neck postoperative defects. A total of 107 patients who underwent head and neck defect reconstruction using modified PMMC flaps after tumor rescetion between Jan 2008 and Dec 2013 were analyzed retrospectively. The success rate of reconstruction with modified PMMC flaps was 94.4% (101/107). Five patients had partial flap necrosis and their wounds healed with dressing change. One patient (0.9%) had total flap necrosis, followed by the second reconstruction using contralateral PMMC flap. The modified falcate PMMC flap can obtain optimum quantity of the skin in the chest and decreasing the closing tension of the donnor site in favor of wound healing. The pedicle without muscle will not only maintain the partial function of the pectoralis major, but also help to avoid pressing the vascular pedicle within the subclavian tunnel. The muscular element the pedicled muscles of the PMMC flap can increase the ability of the flap to resist infection, which can use for covering an exposed carotid artery and improving the neck fibrosis of irradiated patients.

  16. Optimal propulsive flapping in Stokes flows.

    PubMed

    Was, Loïc; Lauga, Eric

    2014-03-01

    Swimming fish and flying insects use the flapping of fins and wings to generate thrust. In contrast, microscopic organisms typically deform their appendages in a wavelike fashion. Since a flapping motion with two degrees of freedom is able, in theory, to produce net forces from a time-periodic actuation at all Reynolds numbers, we compute in this paper the optimal flapping kinematics of a rigid spheroid in a Stokes flow. The hydrodynamics for the force generation and energetics of the flapping motion is solved exactly. We then compute analytically the gradient of a flapping efficiency in the space of all flapping gaits and employ it to derive numerically the optimal flapping kinematics as a function of the shape of the flapper and the amplitude of the motion. The kinematics of optimal flapping are observed to depend weakly on the flapper shape and are very similar to the figure-eight motion observed in the motion of insect wings. Our results suggest that flapping could be a exploited experimentally as a propulsion mechanism valid across the whole range of Reynolds numbers.

  17. Management of Dropped Skull Flaps.

    PubMed

    Abdelfatah, Mohamed AbdelRahman

    2017-01-01

    Dropping a skull flap on the floor is an uncommon and avoidable mistake in the neurosurgical operating theater. This study retrospectively reviewed all incidents of dropped skull flaps in Ain-Shams University hospitals during a 10-year period to show how to manage this problem and its outcome. Thirty-one incidents of dropped skull flaps occurred from January 2004 to January 2014 out of more than 10,000 craniotomies. Follow-up period varied from 20 to 44 months. The bone flap was dropped while elevating the bone (n = 16), while drilling the bone on the operating table (n = 5), and during insertion of the bone flap (n = 10). Treatment included re-insertion of the skull flap after soaking it in povidone iodine and antibiotic solution (n = 17) or after autoclaving (n = 11), or discarding the skull flap and replacing it with a mesh cranioplasty in the same operation (n = 3). No bone or wound infection was noted during the follow-up period. Management of dropped skull flap is its prevention. Replacement of the skull flap, after decontamination, is an option that avoids the expense and time of cranioplasty.

  18. Vortex leading edge flap assembly for supersonic airplanes

    NASA Technical Reports Server (NTRS)

    Rudolph, Peter K. C. (Inventor)

    1997-01-01

    A leading edge flap (16) for supersonic transport airplanes is disclosed. In its stowed position, the leading edge flap forms the lower surface of the wing leading edge up to the horizontal center of the leading edge radius. For low speed operation, the vortex leading edge flap moves forward and rotates down. The upward curve of the flap leading edge triggers flow separation on the flap and rotational flow on the upper surface of the flap (vortex). The rounded shape of the upper fixed leading edge provides the conditions for a controlled reattachment of the flow on the upper wing surface and therefore a stable vortex. The vortex generates lift and a nose-up pitching moment. This improves maximum lift at low speed, reduces attitude for a given lift coefficient and improves lift to drag ratio. The mechanism (27) to move the vortex flap consists of two spanwise supports (24) with two diverging straight tracks (64 and 68) each and a screw drive mechanism (62) in the center of the flap panel (29). The flap motion is essentially normal to the airloads and therefore requires only low actuation forces.

  19. Numerical and experimental investigations on unsteady aerodynamics of flapping wings

    NASA Astrophysics Data System (ADS)

    Yu, Meilin

    The development of a dynamic unstructured grid high-order accurate spectral difference (SD) method for the three dimensional compressible Navier-Stokes (N-S) equations and its applications in flapping-wing aerodynamics are carried out in this work. Grid deformation is achieved via an algebraic blending strategy to save computational cost. The Geometric Conservation Law (GCL) is imposed to ensure that grid deformation will not contaminate the flow physics. A low Mach number preconditioning procedure is conducted in the developed solver to handle the bio-inspired flow. The capability of the low Mach number preconditioned SD solver is demonstrated by a series of two dimensional (2D) and three dimensional (3D) simulations of the unsteady vortex dominated flow. Several topics in the flapping wing aerodynamics are numerically and experimentally investigated in this work. These topics cover some of the cutting-edge issues in flapping wing aerodynamics, including the wake structure analysis, airfoil thickness and kinematics effects on the aerodynamic performances, vortex structure analysis around 3D flapping wings and the kinematics optimization. Wake structures behind a sinusoidally pitching NACA0012 airfoil are studied with both experimental and numerical approaches. The experiments are carried out with Particle Image Velocimetry (PIV) and two types of wake transition processes, namely the transition from a drag-indicative wake to a thrust-indicative wake and that from the symmetric wake to the asymmetric wake are distinguished. The numerical results from the developed SD solver agree well with the experimental results. It is numerically found that the deflective direction of the asymmetric wake is determined by the initial conditions, e.g. initial phase angle. As most insects use thin wings (i. e., wing thickness is only a few percent of the chord length) in flapping flight, the effects of airfoil thickness on thrust generation are numerically investigated by simulating the flow fields around a series of plunging NACA symmetric airfoils with thickness ratio ranging from 4.0% to 20.0% of the airfoil chord length. The contribution of viscous force to flapping propulsion is accessed and it is found that viscous force becomes thrust producing, instead of drag producing, and plays a non-negligible role in thrust generation for thin airfoils. This is closely related to the variations of the dynamics of the unsteady vortex structures around the plunging airfoils. As nature flyers use complex wing kinematics in flapping flight, kinematics effects on the aerodynamic performance with different airfoil thicknesses are numerically studied by using a series of NACA symmetric airfoils. It is found that the combined plunging and pitching motion can outperform the pure plunging or pitching motion by sophisticatedly adjusting the airfoil gestures during the oscillation stroke. The thin airfoil better manipulates leading edge vortices (LEVs) than the thick airfoil (NACA0030) does in studied cases, and there exists an optimal thickness for large thrust generation with reasonable propulsive efficiency. With the present kinematics and dynamic parameters, relatively low reduced frequency is conducive for thrust production and propulsive efficiency for all tested airfoil thicknesses. In order to obtain the optimal kinematics parameters of flapping flight, a kinematics optimization is then performed. A gradient-based optimization algorithm is coupled with a second-order SD Navier-Stokes solver to search for the optimal kinematics of a certain airfoil undergoing a combined plunging and pitching motion. Then a high-order SD scheme is used to verify the optimization results and reveal the detailed vortex structures associated with the optimal kinematics of the flapping flight. It is found that for the case with maximum propulsive efficiency, there exists no leading edge separation during most of the oscillation cycle. In order to provide constructive suggestions to the design of micro-air-vehicles (MAVs), 3D simulations of the flapping wings are carried out in this work. Both the rectangular and bio-inspired wings with different kinematics are investigated. The formation process of two-jet-like wake patterns behind the finite-span flapping wing is found to be closely related to the interaction between trailing edge vortices and tip vortices. Then the effects of the wing planforms on the aerodynamics performance of the finite-span flapping wings are elucidated in terms of the evolution and dynamic interaction of unsteady vortex structures.

  20. Biomimetic Beetle-Inspired Flapping Air Vehicle Actuated by Ionic Polymer-Metal Composite Actuator

    PubMed Central

    Zhao, Yang; Xu, Di; Sheng, Jiazheng; Meng, Qinglong; Wu, Dezhi; Wang, Lingyun; Xiao, Jingjing; Lv, Wenlong; Sun, Daoheng

    2018-01-01

    During the last decades, the ionic polymer-metal composite (IPMC) received much attention because of its potential capabilities, such as large displacement and flexible bending actuation. In this paper, a biomimetic flapping air vehicle was proposed by combining the superiority of ionic polymer metal composite with the bionic beetle flapping principle. The blocking force was compared between casted IPMC and IPMC. The flapping state of the wing was investigated and the maximum displacement and flapping angle were measured. The flapping displacement under different voltage and frequency was tested. The flapping displacement of the wing and the support reaction force were measured under different frequency by experiments. The experimental results indicate that the high voltage and low frequency would get large flapping displacement. PMID:29682006

  1. Pressure investigation of NASA leading edge vortex flaps on a 60 deg Delta wing

    NASA Technical Reports Server (NTRS)

    Marchman, J. F., III; Donatelli, D. A.; Terry, J. E.

    1983-01-01

    Pressure distributions on a 60 deg Delta Wing with NASA designed leading edge vortex flaps (LEVF) were found in order to provide more pressure data for LEVF and to help verify NASA computer codes used in designing these flaps. These flaps were intended to be optimized designs based on these computer codes. However, the pressure distributions show that the flaps wre not optimum for the size and deflection specified. A second drag-producing vortex forming over the wing indicated that the flap was too large for the specified deflection. Also, it became apparent that flap thickness has a possible effect on the reattachment location of the vortex. Research is continuing to determine proper flap size and deflection relationships that provide well-behaved flowfields and acceptable hinge-moment characteristics.

  2. Noise Reduction of Aircraft Flap

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V. (Inventor); Brooks, Thomas F. (Inventor)

    2009-01-01

    A reduction in noise radiating from a side of a deployed aircraft flap is achieved by locating a slot adjacent the side of the flap, and then forcing air out through the slot with a suitable mechanism. One, two or even three or more slots are possible, where the slot is located at one;or more locations selected from a group of locations comprising a top surface of the flap, a bottom surface of the flap, an intersection of the top and side surface of the flap, an intersection of the bottom and side surfaces of the flap, and a side surface of the flap. In at least one embodiment the slot is substantially rectangular. A device for adjusting a rate of the air forced out through the slot can also be provided.

  3. Vulva reconstruction after pelvic exenteration, using a unique combination of two flaps

    PubMed Central

    van Bommel, Annelotte C M; Schreuder, Henk W R; Schellekens, Pascal P A

    2011-01-01

    A 64-year-old woman with recurrence of carcinoma of the vulva in an irradiated area received an en-bloc total pelvic exenteration. Reconstruction of the pelvic defect was performed with an anterolateral thigh (ALT) flap and a rectus abdominis muscle (RAM) flap (PM/RAM). This combination of flaps is unique, with excellent results. In a large defect, often irradiated in advance, well-vascularised tissue should be placed. Multiple flaps can be used to reconstruct these large pelvic defects, each with their own advantages and disadvantages. The combination of flaps used in this case uses the good properties of both flaps: the reliable and well-vascularised PM/RAM in combination with the ALT flap to provide much bulk in extreme large defects. PMID:22692483

  4. Experimental study on thrust and power of flapping-wing system based on rack-pinion mechanism.

    PubMed

    Nguyen, Tuan Anh; Vu Phan, Hoang; Au, Thi Kim Loan; Park, Hoon Cheol

    2016-06-20

    This experimental study investigates the effect of three parameters: wing aspect ratio (AR), wing offset, and flapping frequency, on thrust generation and power consumption of a flapping-wing system based on a rack-pinion mechanism. The new flapping-wing system is simple but robust, and is able to create a large flapping amplitude. The thrust measured by a load cell reveals that for a given power, the flapping-wing system using a higher wing AR produces larger thrust and higher flapping frequency at the wing offset of 0.15[Formula: see text] or 0.20[Formula: see text] ([Formula: see text] is the mean chord) than other wing offsets. Of the three parameters, the flapping frequency plays a more significant role on thrust generation than either the wing AR or the wing offset. Based on the measured thrusts, an empirical equation for thrust prediction is suggested, as a function of wing area, flapping frequency, flapping angle, and wing AR. The difference between the predicted and measured thrusts was less than 7%, which proved that the empirical equation for thrust prediction is reasonable. On average, the measured power consumption to flap the wings shows that 46.5% of the input power is spent to produce aerodynamic forces, 14.0% to overcome inertia force, 9.5% to drive the rack-pinion-based flapping mechanism, and 30.0% is wasted as the power loss of the installed motor. From the power analysis, it is found that the wing with an AR of 2.25 using a wing offset of 0.20[Formula: see text] showed the optimal power loading in the flapping-wing system. In addition, the flapping frequency of 25 Hz is recommended as the optimal frequency of the current flapping-wing system for high efficiency, which was 48.3%, using a wing with an AR of 2.25 and a wing offset of 0.20[Formula: see text] in the proposed design.

  5. [Effects and related mechanism of bivalirudin on the survival of random skin flap on the back of rat].

    PubMed

    Cai, L Y; Wang, T; Lin, D S; Lu, D

    2017-04-20

    Objective: To investigate the effects and related mechanism of bivalirudin on the survival of random skin flap on the back of rat. Methods: Thirty SD rats were divided into bivalirudin group and normal saline group according to the random number table, with 15 rats in each group. The random flap model with size of 9 cm×3 cm was reproduced on the back of rats in two groups. Immediately post injury, rats in bivalirudin group were intraperitoneally injected with 5 mg/mL bivalirudin (0.8 mL/kg), while rats in normal saline group were intraperitoneally injected with normal saline (0.8 mL/kg) once a day. The continuous injection lasted for 7 days. The flap was divided into distal area, middle area and proximal area averagely based on the flap blood supply. On post injury day (PID) 1, 3, and 7, the overall survival of each area of flap was observed with naked eyes. On PID 7, the survival rate of flap was calculated, and then the morphology of skin tissue at the center of the three areas of flap was observed by HE staining, the microvessel density (MVD) of the middle area of flap was calculated, and the expression of vascular endothelial growth factor (VEGF) of the middle area of flap was detected with immunohistochemical staining. Data were processed with t test. Results: (1) On PID 1, flaps of rats in two groups had different degrees of swelling, mainly concentrated in distal area, but there was no obvious necrosis. The middle area and proximal area of flaps in two groups were survived. On PID 3, the necrosis of flaps of rats in two groups was concentrated in the middle area, while the proximal area of flap was still in survival state, and most distal area of flap was necrosis with a little scab. On PID 7, the necrosis of middle area of flaps of rats in two groups was gradually fused, and the survival area of flap of rats in bivalirudin group was larger than that in normal saline group. The distal area of flap was almost necrotic, and the proximal area of flap was almost survived. (2) On PID 7, the survival rate of flap of rats in bivalirudin group was (64±4)%, significantly higher than that in normal saline group [(45±3)%, t =13.49, P <0.01]. (3) On PID 7, the histological morphology of distal area of flap of rats in two groups was similar, the inflammatory cells were infiltrated abundantly, and tissue edema was obvious. A large number of new blood vessels appeared in the middle area of flap of rats in bivalirudin group, with the formation of collateral vessels, and basic dilation of new blood vessels was seen. There were fewer new blood vessels appeared in the middle area of flap of rats in normal saline group, and dilation of new blood vessels was not obvious. There was little inflammatory cells infiltration in the proximal area of flap of rats in two groups. Compared with that in normal saline group, tissue edema extent of proximal area of flap of rats in bivalirudin group was less, and expansion was observed in more blood vessels. (4) The MVD of middle area of flap of rats in bivalirudin group was (26±5)/mm(2,) significantly higher than that in normal saline group [(18±3)/mm(2,) t =5.43, P <0.05]. (5) The expression of VEGF of middle area of flap of rats in bivalirudin group was 6 534±384, significantly higher than that in normal saline group (4 659±448, t =12.31, P <0.05). Conclusions: Bivalirudin can promote the survival of random skin flap in rats, and the mechanisms may include reducing the formation of thrombosis, improving the blood supply of flap, and increasing the expression of VEGF, promoting the formation of new blood vessels.

  6. Early experience with the free lumbar artery perforator flap for breast reconstruction.

    PubMed

    Peters, Kevin T; Blondeel, Phillip N; Lobo, Fernando; van Landuyt, Koenraad

    2015-08-01

    Autologous breast reconstruction has become a progressively more popular method of breast reconstruction. A wide variety of perforator flaps have been described and subsequently refined to decrease donor-site morbidity. Recently, the lumbar artery perforator (LAP) flap has been reported as an option for autologous breast reconstruction. This study summarises the prospectively gathered data of 35 free LAP flaps for breast reconstruction in 28 patients. The mean follow-up was 18 months. The internal mammary artery and the venae comitantes were used as recipient vessels in all reconstructions. In 80% of the reconstructions (28 flaps), an interposition graft was used. Six flaps (17%) had to be revised for venous thrombosis. Two of the revised flaps (5.7%) could not be salvaged, and total flap necrosis occurred. The mean operating time was 6 h and 15 min, 6 h and 39 min when an interposition graft was used and 5 h and 23 min when no interposition graft was necessary. The LAP flap should be considered as a further alternative for breast reconstruction in patients in whom a deep inferior epigastric artery perforator (DIEAP) flap is not possible or not desirable. Shaping of this flap is easier compared to any other flaps due to the quality of the lumbar fat and the gluteal extension. An interposition graft is frequently used to facilitate anastomosis, either to lengthen the pedicle or to resolve size mismatch. This is a disadvantage of the LAP flap. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Full-scale Wind-tunnel and Flight Tests of a Fairchild 22 Airplane Equipped with External-airfoil Flaps

    NASA Technical Reports Server (NTRS)

    Reed, Warren D; Clay, William C

    1937-01-01

    Wind-tunnel and flight tests have been made of a Fairchild 22 airplane equipped with a wing having external-airfoil flaps that also perform the function of ailerons. Lift, drag, and pitching-moment coefficients of the airplane with several flap settings, and the rolling- and yawing-moment coefficients with the flaps deflected as ailerons were measured in the full-scale tunnel with the horizontal tail surfaces and propeller removed. The effect of the flaps on the low speed and on the take-off and landing characteristics, the effectiveness of flaps when used as ailerons, and the forces required to operate them as ailerons were determined in flight. The wind-tunnel tests showed that the flaps increased the maximum lift coefficient of the airplane from 1.51 with the flap in the minimum drag position to 2.12 with the flap in the minimum drag position to 2.12 with the flap deflected 30 degrees. In the flight tests the minimum speed decreased from 46.8 miles per hour with the flaps up to 41.3 miles per hour with the flaps deflected. The required take-off run to attain a height of 50 feet was reduced from 820 to 750 feet and the landing run from a height of 50 feet was reduced from 930 to 480 feet. The flaps for this installation gave lateral control that was not entirely satisfactory. Their rolling action was good but the adverse yaw resulting from their use was greater than is considerable, and the stick forces required to operate them increased too rapidly with speed.

  8. Lower Extremity Reconstruction with Free Gracilis Flaps

    PubMed Central

    Nicoson, Michael C; Parikh, Rajiv P; Tung, Thomas H

    2017-01-01

    Background There have been significant advancements in lower extremity reconstruction over the last several decades, and the plastic surgeon’s armamentarium has grown to include free muscle and fasciocutaneous flaps along with local perforator and propeller flaps. While we have found a use for a variety of techniques for lower extremity reconstruction, the free gracilis has been our workhorse flap due to the ease of harvest, reliability, and low donor site morbidity. Methods This is a retrospective review of a single surgeon’s series of free gracilis flaps utilized for lower extremity reconstruction. Demographic information, comorbidities, outcomes and secondary procedures were analyzed. Results We identified 24 free gracilis flaps. The duration from injury to free flap coverage was 7 days or less in 6 patients, 8–30 days in 11 patients, 31–90 days in 4 patients, and > 90 days in 3 patients. There were 22 (92%) successful flaps and an overall limb salvage rate of 92%. There was one partial flap loss. Two flaps underwent incision and drainage in the operating room for infection. Two patients developed donor site hematomas. Four patients underwent secondary procedures for contouring. Our subset of pediatric patients had 100% flap survival and no secondary procedures at a mean 30 month follow up. Conclusions This study demonstrates the utility of the free gracilis flap in reconstruction of small to medium sized defects of the lower extremity. This flap has a high success rate and low donor site morbidity. Atrophy of the denervated muscle over time allows for good shoe fit, often obviating the need for secondary contouring procedures. PMID:28024305

  9. The First Dorsal Metatarsal Artery Perforator Propeller Flap.

    PubMed

    Hallock, Geoffrey G

    2016-06-01

    Distal foot and toe defects requiring a vascularized flap for coverage have very limited options, oftentimes justifying even a free flap. Perforator flaps in general and propeller flaps in particular have opened up an entirely new subset of local tissue transfer alternatives that can potentially avoid the difficulties that accompany microvascular tissue transfers. The first dorsal metatarsal artery (FDMA) perforator propeller flap represents another variation of this theme. A standard FDMA flap from the dorsum of the foot was raised in reversed fashion based on the distal communicating branch or "perforator" from the plantar foot circulation in 2 patients with great toe defects. All distal skin tissue between this perforator and the defect was kept with the FDMA flap as an attached minor blade, to thereby create an FDMA propeller flap. Salvage of the great toe in both patients was achieved. The benefit of the minor blade of the propeller was to fill a portion of the donor site defect of the traditional FDMA major blade, to permit tension-free donor site closure of the dorsal foot without sequela. The distal-based FDMA flap can be useful as a local flap for coverage of distal foot and toe wounds, but direct donor site closure can be problematic as mirrored by its relative the dorsalis pedis flap. The FDMA perforator propeller flap variation can achieve the same reconstructive goals while simultaneously transferring vascularized tissue into the dorsal foot donor site to thereby minimize the tension if direct closure is possible or minimize the need for a skin graft in this notoriously difficult region.

  10. The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction.

    PubMed

    Yang, Hee Jun; Lee, Dong Hun; Kim, Yang Woo; Lee, Sang Gu; Cheon, Young Woo

    2016-11-01

    The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was 4.31±2.14 cm. The mean vertical height of the trapezius muscle flap pivot point was 9.53±2.08 cm from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction.

  11. The Trapezius Muscle Flap: A Viable Alternative for Posterior Scalp and Neck Reconstruction

    PubMed Central

    Yang, Hee Jun; Kim, Yang Woo; Lee, Sang Gu

    2016-01-01

    Background The trapezius muscle flap is not usually the first reconstructive option for skin and soft tissue defects in the posterior neck and scalp due to surgeons' unfamiliarity with the surgical anatomy and developments in free tissue transfer techniques. The goals of this study were to describe the clinical use of trapezius flaps in posterior neck and scalp reconstruction, and to investigate the vascular anatomy of trapezius flaps in Asians in order to obtain information facilitating the safe design and elevation of flaps in which most of the muscle is preserved. Methods A retrospective chart review was performed of 10 patients who underwent trapezius muscle flap for posterior neck and scalp defects. We also performed an anatomical study of 16 flaps harvested from 8 preserved Asian adult cadavers and evaluated the main landmarks relevant for trapezius muscle flap. Results In the anatomical study, the mean vertical height from the inferior angle of the scapula to the point at which the superficial cervical artery penetrated the trapezius was 4.31±2.14 cm. The mean vertical height of the trapezius muscle flap pivot point was 9.53±2.08 cm from the external occipital protuberance. Among the 10 flaps, partial necrosis on the overlaid skin graft occurred in 1 patient and postoperative seroma occurred in another patient. Conclusions Vascular variations in the trapezius muscle flap are uncommon in Asians, but when present, such variations appear to have little impact on harvesting the flap or on its circulation. The trapezius muscle flap is a viable alternative for posterior neck and scalp reconstruction. PMID:27896183

  12. Internal limiting membrane flap transposition for surgical repair of macular holes in primary surgery and in persistent macular holes.

    PubMed

    Leisser, Christoph; Hirnschall, Nino; Döller, Birgit; Varsits, Ralph; Ullrich, Marlies; Kefer, Katharina; Findl, Oliver

    2018-03-01

    Classical or temporal internal limiting membrane (ILM) flap transposition with air or gas tamponade are current trends with the potential to improve surgical results, especially in cases with large macular holes. A prospective case series included patients with idiopathic macular holes or persistent macular holes after 23-G pars plana vitrectomy (PPV) and ILM peeling with gas tamponade. In all patients, 23-G PPV and ILM peeling with ILM flap transposition with gas tamponade and postoperative face-down position was performed. In 7 of 9 eyes, temporal ILM flap transposition combined with pedicle ILM flap could be successfully performed and macular holes were closed in all eyes after surgery. The remaining 2 eyes were converted to pedicle ILM flap transposition with macular hole closure after surgery. Three eyes were scheduled as pedicle ILM flap transposition due to previous ILM peeling. In 2 of these eyes, the macular hole could be closed with pedicle ILM flap transposition. In 3 eyes, free ILM flap transposition was performed and in 2 of these eyes macular hole could be closed after surgery, whereas in 1 eye a second surgery, performed as pedicle ILM flap transposition, was performed and led to successful macular hole closure. Use of ILM flaps in surgical repair of macular hole surgery is a new option of treatment with excellent results independent of the diameter of macular holes. For patients with persistent macular holes, pedicle ILM flap transposition or free ILM flap transposition are surgical options.

  13. My First 100 Consecutive Microvascular Free Flaps: Pearls and Lessons Learned in First Year of Practice

    PubMed Central

    2013-01-01

    Background: Microvascular reconstruction for oncologic defects is a challenging and rewarding endeavor, and successful outcomes are dependent on a multitude of factors. This study represents lessons learned from a personal prospective experience with 100 consecutive free flaps. Methods: All patients’ medical records were reviewed for demographics, operative notes, and complications. Results: Overall 100 flaps were performed in 84 consecutive patients for reconstruction of breast, head and neck, trunk, and extremity defects. Nineteen patients underwent free flap breast reconstruction with 10 patients undergoing bilateral reconstruction and 2 patients receiving a bipedicle flap for reconstruction of a unilateral breast defect. Sixty-five free flaps were performed in 61 patients with 3 patients receiving 2 free flaps for reconstruction of extensive head and neck defects and 1 patient who required a second flap for partial flap loss. Trunk and extremity reconstruction was less common with 2 free flaps performed in each group. Overall, 19 patients (22.6%) developed complications and 14 required a return to the operating room. There were no flap losses in this cohort. Thorough preoperative evaluation and workup, meticulous surgical technique and intraoperative planning, and diligent postoperative monitoring and prompt intervention are critical for flap success. Conclusions: As a young plastic surgeon embarking in reconstructive plastic surgery at an academic institution, the challenges and dilemmas presented in the first year of practice have been daunting but also represent opportunities for learning and improvement. Skills and knowledge acquired from time, experience, and mentors are invaluable in optimizing outcomes in microvascular free flap reconstruction. PMID:25289221

  14. [Pedicled versus free TRAM flap for breast reconstruction].

    PubMed

    Galla, T J; Lukas, B; Feller, A M

    1999-03-01

    In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.

  15. Angiographic delay: a viable alternative to surgical delay.

    PubMed

    Aboutanos, Sharline Z; Spinos, Efstathios; Blanchet, Nadia P

    2012-06-01

    Selective embolization of the inferior epigastric arteries can serve as a method for transverse rectus abdominis musculocutaneous (TRAM) flap delay. The purpose of this study was to determine whether delay by selective arterial embolization is comparable to traditionally surgically delayed TRAM flaps as reported in the literature, in terms of skin and fat necrosis, and to examine whether certain risk factors play a role in TRAM flap fat necrosis despite angiographic delay. Retrospective chart review was performed for 88 consecutive patients who underwent unilateral TRAM flap breast reconstruction after selective embolization of bilateral inferior epigastric arteries. Between 1997 and 2009, 88 pedicled TRAM flaps were performed for breast reconstruction in women with a mean age of 49.7 years. No patients had flap skin necrosis or total flap loss. In all, 13.6% patients had TRAM flap fat necrosis. Two patients in the TRAM fat necrosis group (16.7%) had a positive history of smoking, which was a statistically significant risk factor for necrosis (P = 0.048). Outcomes of pedicled TRAM flaps delayed by selective arterial embolization are comparable to historical controls of those delayed by traditional surgical means (ligation of artery and vein) and better than nondelayed flaps. Smoking remains a significant risk factor for TRAM flap fat necrosis despite the benefit of delay.

  16. Reproducibility of flap thickness with IntraLase FS and Moria LSK-1 and M2 microkeratomes.

    PubMed

    Talamo, Jonathan H; Meltzer, Jeremy; Gardner, John

    2006-06-01

    To compare flap thickness reproducibility of the femtosecond laser and two mechanical microkeratomes. Flap thickness for all eyes was measured as the difference between the preoperative (day of surgery) full corneal thickness and post-flap creation central stromal bed thickness using ultrasonic pachymetry. Flap thickness values produced by three different microkeratome systems were compared for accuracy and reproducibility. For 99 flaps created using the IntraLase FS laser with an intended thickness of 110 microm, the mean achieved thickness was 119 +/- 12 microm (range: 82 to 149 microm). In 100 eyes treated with the Moria LSK-1 microkeratome with an intended flap thickness of 160 microm, the mean achieved thickness was 130 +/- 19 microm (range: 71 to 186 microm). In 135 eyes treated with the Moria M2 microkeratome with an intended flap thickness of 130 microm, mean thickness was 142 +/- 24 microm (range: 84 to 203 microm). The standard deviation and range of corneal flap thickness created with the IntraLase FS laser was significantly smaller than either mechanical microkeratome (P < .0001). When compared to two commonly used mechanical microkeratomes, mean achieved flap thickness was more reproducible with the IntraLase FS laser, reducing the comparative risk of overly thick flaps.

  17. Reconstruction of soft tissue after complicated calcaneal fractures.

    PubMed

    Koski, E Antti; Kuokkanen, Hannu O M; Koskinen, Seppo K; Tukiainen, Erkki J

    2004-01-01

    A total of 35 flap reconstructions were done to cover exposed calcaneal bones in 31 patients. All patients had calcaneal fractures, 19 of which were primarily open. Soft tissue reconstruction for the closed fractures was indicated by a postoperative wound complication. A microvascular flap was used for reconstruction in 21 operations (gracilis, n = 11; anterolateral thigh, n = 5; rectus abdominis, n = 3; and latissimus dorsi, n = 2). A suralis neurocutaneous flap was used in eight, local muscle flaps in three, and local skin flaps in three cases. The mean follow-up time was 14 months (range 3 months-4 years). One suralis flap failed and was replaced by a latissimus dorsi flap. Necrosis of the edges that required revision affected three flaps. Deep infection developed in two patients and delayed wound healing in another four. During the follow-up the soft tissues healed in all patients and there were no signs of calcaneal osteitis. Flaps were considered too bulky in five patients. Soft tissues heal most rapidly with microvascular flaps. In the long term, gracilis muscle covered with free skin grafts gives a good contour to the foot. The suralis flap is reliable and gives a good final aesthetic outcome. Local muscles can be transposed for reconstruction in small defects.

  18. A simple concept for covering pressure sores: wound edge-based propeller perforator flap.

    PubMed

    Kelahmetoglu, Osman; Van Landuyt, Koenraad; Yagmur, Caglayan; Sommeling, Casper E; Keles, Musa K; Tayfur, Volkan; Simsek, Tekin; Demirtas, Yener; Guneren, Ethem

    2017-12-01

    We present a new surgical modification to allow propeller perforator flaps to cover pressure sores at various locations. We used a propeller perforator flap concept based on the detection of newly formed perforator vessels located 1 cm from the wound margin and stimulated by the chronic inflammation process. Between January 2009 and January 2017, 33 wound edge-based propeller perforator flaps were used to cover pressure sores at various locations in 28 patients. In four cases more than one flap was used on the same patient. The patients comprised 18 males and 10 females with a mean age of 41·25 (range, 16-70) years. All patients underwent follow-up for 0-12 months. The mean follow-up duration was 5·03 months. Venous congestion was observed in three flaps that were rotated by 180° (9·1%). However, there was a significant difference between flaps rotated by 90° and 180° according to the complication rate (P = 0·034). Out of 33 flaps, 29 flaps healed uneventfully. Patients were able to sit and lie on their flaps three weeks after surgery. In our study, we were able to obtain satisfying final results using these novel flaps. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  19. Anatomical basis of the extended TDAP flap: study of its territories of vascularization and its volume.

    PubMed

    Dast, Sandy; Havet, Eric; Dessena, Lidia; Abdulshakoor, Abeer; Alharbi, Mohammed; Vaucher, Richard; Herlin, Christian; Sinna, Raphael

    2017-08-01

    The concept of extended thoracodorsal artery perforator (TDAP) flap was described in 2015 for breast reconstruction. Our anatomical study aims to identify the territories vascularised by the thoracodorsal artery perforator via the deep muscular fascial network. The second goal was to define the volume of the extended TDAP flap. Ten extended TDAP flaps were dissected on 5 fresh human cadavers. Around the classical skin paddle of a TDAP flap, the dissections were performed in a subfascial level, including the muscular fascia and the adipose tissue compartments to increase the volume of the flap. After injection of methylene blue in the thoracodorsal artery, we measured the length and width, the surface and the volume of the coloured flap. The mean sizes of the extended TDAP flap were 24.9 cm × 20.1 cm. The mean surface of the total vascularization zone was 441 cm 2 . The mean volume of the vascularized flap was 193 ml. The thoracodorsal artery perforator via the deep muscular fascial network allows us to harvest a flap of 25 cm × 20 cm with a mean surface of 441 cm² and a mean volume of 193 ml. The extended TDAP flap is a credible option in breast reconstruction.

  20. Latissimus dorsi myocutaneous flap for breast reconstruction: bad rap or good flap?

    PubMed

    Perdikis, Galen; Koonce, Stephanie; Collis, George; Eck, Dustin

    2011-01-01

    This article serves to review latissimus dorsi myocutaneous flap as an option for breast reconstruction postmastectomy. Since the introduction of the latissimus dorsi myocutaneous flap in the late 1970s, its use has always been as a secondary technique, particularly after the development of the transverse rectus abdominus myocutaneous flap in the 1980s. A literature review of the history of latissimus dorsi myocutaneous flap utilized for breast reconstruction as well as a review of our institution's experience with latissimus dorsi myocutaneous flap and tissue expander placement was performed. There remains a paucity of published studies investigating latissimus dorsi myocutaneous flap for breast reconstruction. Most studies have small numbers and do not utilize tissue expanders. More recently several small studies have been published that show acceptably low complication rates with aesthetically pleasing outcomes when latissimus dorsi myocutaneous flap is employed with a tissue expander. At our institution, we have employed latissimus dorsi myocutaneous flap with tissue expander placement for both delayed and immediate reconstruction with subsequent replacement with a permanent implant with a capsular contraction rate of 10.5%. Our data and others more recently published demonstrate very acceptable capsular contracture rates and aesthetic outcomes, particularly when an expander is utilized. The latissimus dorsi myocutaneous flap remains an excellent choice for breast reconstruction with a low risk of complications.

  1. [Aesthetic reconstruction strategy for postburn facial scar and its clinical effect].

    PubMed

    Ma, X J; Li, W Y; Liu, C H; Li, Y

    2016-08-20

    To explore the aesthetic reconstruction strategy for postburn facial scar and its clinical effect. Three hundred and forty-two patients with postburn facial scars were hospitalized from January 2000 to December 2015. Local expanded flap or deltopectoral expanded flap was used for reconstruction according to the location and size of the facial scar. The forehead expanded flap could be chosen for the scar in dorsum nasi or inferior eyelid. The local expanded flap was chosen when the scar width was smaller than 5 cm in cheek, chin, and marginal mandible region. The expanded deltopectoral flap was chosen when the scar width was larger than 5 cm in cheek, chin, and marginal mandible region or the scar contracture was too serious to cause displacement of lips, nose, or eyelid, and the wound width was larger than 5 cm after release. The facial scars of 82 patients, with size ranged from 6.0 cm×2.5 cm to 15.0 cm×10.0 cm, were reconstructed with expanded local flaps. The facial scars of 260 patients, with size ranged from 8.0 cm×7.0 cm to 38.0 cm×13.0 cm, were reconstructed with expanded deltopectoral flaps. After expansion of 2 to 6 months, the facial scars were excised and completely released first of all. The transfer way of local flap and size of deltopectoral flap with pedicle were designed according to the size and shape of the wound. Three weeks after transfer of deltopectoral flap, flap delay procedure was conducted. One week later, the pedicle was severed from the flap to reconstruct the remaining scar. Anti-scar medicine, laser therapy, and elasticized fabric were used postoperatively on the scars in both donor and recipient sites. During the postoperative follow-up for 3 to 12 months, the flaps of 40 out of 82 cases reconstructed with expanded local flaps were in good color and texture. Before 2008, mild scar hyperplasia was observed in the incision of 19 patients; with application of laser after 2008, the number of patients with scar hyperplasia was decreased. During the postoperative follow-up for 3 to 12 months, the flaps of 90 out of 260 cases reconstructed with expanded deltopectoral flaps were in good color and texture. The expander was exposed from the incision in 15 patients, while it did not affect the later treatment. Nine unilateral flaps showed poor blood circulation at the distal end, and they were healed after dressing change. In the early phase, necrosis was observed in one flap after transfer, and it was healed after transplantation of free skin graft. Scar hyperplasia was observed in the chest donor site of one patient, and it was improved after laser therapy. Postburn facial scar could be reconstructed with local or deltopectoral flaps, following the principle of similarity. The expansion could increase the size of the flaps, reduce the thickness of the flaps, and lower the donor site damage.

  2. Distant Pedicle Flaps for Soft Tissue Coverage of Severely Burned Hands: An Old Idea Revisited

    DTIC Science & Technology

    2001-09-01

    choice remains immedi- Fig. 2. Groin flap. Groin flap revision with liposuction . D.J. Barillo et al. / Burns 27 (2001) 613–619 617 Fig. 2. (Continued...to cover hand defects. Secondary liposuction procedures are effec- tive in debulking the flap. The Tensor Fascia Lata Flap (TFL) is based upon the

  3. 14 CFR 25.1511 - Flap extended speed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flap extended speed. 25.1511 Section 25... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so that it does not exceed the design flap speed V F chosen under §§ 25.335(e) and 25.345, for the...

  4. 14 CFR 25.1511 - Flap extended speed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flap extended speed. 25.1511 Section 25... Limitations § 25.1511 Flap extended speed. The established flap extended speed V FE must be established so that it does not exceed the design flap speed V F chosen under §§ 25.335(e) and 25.345, for the...

  5. Divided and Sliding Superficial Temporal Artery Flap for Primary Donor-site Closure

    PubMed Central

    Sugio, Yuta; Seike, Shien; Hosokawa, Ko

    2016-01-01

    Summary: Superficial temporal artery (STA) flaps are often used for reconstruction of hair-bearing areas. However, primary closure of the donor site is not easy when the size of the necessary skin island is relatively large. In such cases, skin grafts are needed at the donor site, resulting in baldness. We have solved this issue by applying the divided and sliding flap technique, which was first reported for primary donor-site closure of a latissimus dorsi musculocutaneous flap. We applied this technique to the hair-bearing STA flap, where primary donor-site closure is extremely beneficial for preventing baldness consequent to skin grafting. The STA flap was divided into 3, and creation of large flap was possible. Therefore, we concluded that the divided and sliding STA flap could at least partially solve the donor-site problem. Although further investigation is necessary to validate the maximum possible flap size, this technique may be applicable to at least small defects that are common after skin cancer ablation or trauma. PMID:27975020

  6. Perforator Peroneal Artery Flap for Tongue Reconstruction.

    PubMed

    Chauhan, Shubhra; Chavre, Sachin; Chandrashekar, Naveen Hedne; B S, Naveen

    2017-03-01

    Reconstruction has evolved long way from primary closure to flaps. As time evolved, better understanding of vascularity of flap has led to the development of innovative reconstructive techniques. These flaps can be raised from various parts of the body for reconstruction and have shown least donor site morbidity. We use one such peroneal artery perforator flap for tongue reconstruction with advantage of thin pliable flap, minimal donor site morbidity and hidden scar. Our patient 57yrs old lady underwent wide local excision with selective neck dissection. Perforators are marked about 10 and 15 cm inferiorly from the fibular head using hand held Doppler. Leg is positioned in such a way to give better exposure during dissection of the flap and flap is harvested under a tourniquet with pressure kept 350 mm Hg. The perforator is kept at the eccentric location, so as to gain length of the pedicle. Skin incison is placed over the peroneal muscle and deepened unto the deep facia, then the dissection is continued over the muscle and the perforator arising from the lateral septum. The proximal perforator about 10 cm from the fibular head is a constant perforator and bigger one, which is traced up to the peroneal vessel. We could get a 6 cm of pedicle length. Finally the flap is islanded on this perforator and the pedicle is ligated and flap harvested. Anastamosis was done to the ipsilateral side to facial vessels. The donor site is closed primarily and in the upper half one can harvest 5 cm width flap without requiring a skin graft along with a length of 8 to 12 cm. Various local and free flap has been used for reconstruction of partial tongue defects with its obvious donor site problems, like less pliable skin and not so adequate tissue from local flaps and sacrificing a important artery as in radial forearm flap serves as the work horse in reconstruction of partial tongue defects, Concept of super microsurgery was popularized by Japanese in 1980s and the concept of angiosome proposed by Taylor paved the way for development of new flaps. True perforator flaps are those where the source vessel is left undisturbed and overlying skin flap is raised. Yoshimura proposed cutaneous flap could be raised from peroneal artery (Br J Plast Surg 42:715-718, 1989). Wolff et al. (Plast Reconstr Surg 113:107-113, 2004) first used perforator based peroneal artery flap for oral reconstruction. Location of perforators vary, hence pre operative localisation can be done by ultrasound doppler, CT angio or MR angiography. Disadvantages over radial flap include varying anatomic location of perforators, need for imaging and difficult dissection of delicate vessels through muscles and hence a learning curve. Our patient had an arterial thrombus within few hours post-operatively which was successfully salvaged with immediate re-exploration and re-anastomosis of artery. Post-operative healing was uneventful and donor site was closed primarily without the need for graft. Perforator peroneal flap serves as a useful armamentarium for reconstruction of moderate size defects of tongue, buccal mucosa and floor of mouth with advantages of thin pliable flap, minimal donor site morbidity and hidden scar.

  7. A shark attack treated in a tertiary care centre: Case report and review of the literature.

    PubMed

    Roy, Mélissa; Plant, Mathew A; Snell, Laura

    2018-01-01

    Although uncommon, shark attacks can lead to devastating outcomes for victims. Surgeons also face unique challenges during operative management such as exsanguination, shock, specific injury patterns and infections. This case report presents the management of a 39-year-old previously healthy female attacked by a shark while on vacation in Mexico. The patient sustained severe injuries to her left arm and her left thigh. She was transferred to a Canadian institution after ambiguous operative management in Mexico and presented with no clear antibiotic coverage and a Volkman's contracture of the left upper extremity. In total, the patient underwent four washouts of wounds, two split-thickness skin grafts, one free anterolateral thigh flap, and one free transverse rectus abdominus myocutaneous flap for the reconstruction and salvage of the left lower extremity. This article highlights the specifics of this case and describes important points in managing these devastating injuries.

  8. A shark attack treated in a tertiary care centre: Case report and review of the literature

    PubMed Central

    Roy, Mélissa; Plant, Mathew A; Snell, Laura

    2018-01-01

    Although uncommon, shark attacks can lead to devastating outcomes for victims. Surgeons also face unique challenges during operative management such as exsanguination, shock, specific injury patterns and infections. This case report presents the management of a 39-year-old previously healthy female attacked by a shark while on vacation in Mexico. The patient sustained severe injuries to her left arm and her left thigh. She was transferred to a Canadian institution after ambiguous operative management in Mexico and presented with no clear antibiotic coverage and a Volkman’s contracture of the left upper extremity. In total, the patient underwent four washouts of wounds, two split-thickness skin grafts, one free anterolateral thigh flap, and one free transverse rectus abdominus myocutaneous flap for the reconstruction and salvage of the left lower extremity. This article highlights the specifics of this case and describes important points in managing these devastating injuries. PMID:29076325

  9. Congenital Partial Absence of Trapezius with Variant Pattern of Rectus Sheath.

    PubMed

    Tigga, Sarika Rachel; Goswami, Preeti; Khanna, Jugesh

    2016-04-01

    Musculocutaneous pedicled/free flaps are an essential prerequisite for reconstructive surgery. Amongst the trunk muscles commonly harvested for flaps, the trapezius and rectus abdominis provide satisfactory coverage for cranial and trunk defects. unilateral/bilateral or partial congenital absence of trapezius muscle is well documented and may result in muscular imbalances compromising posture and limb movements. During routine cadaveric dissection, we encountered a case of bilateral partial absence of occipital part of the trapezius muscle. Concurrently, the ventral abdominal musculature displayed the aponeurosis of transversus abdominis muscle solely forming the posterior wall of the rectus sheath. These conjointly occurring anomalies advocate a compensatory strengthening of the anterior wall of rectus sheath in response to the congenital absence of occipital part of the trapezius, probably to counteract the postural instability. The present study focuses on recognition of compensatory mechanisms resulting from congenital variations as identification of such processes may prevent chronic debilitating conditions.

  10. Lifting-surface theory for calculating the loading induced on a wing by a flap

    NASA Technical Reports Server (NTRS)

    Johnson, W. A.

    1972-01-01

    A method is described for using lifting-surface theory to obtain the pressure distribution on a wing with a trailing-edge flap or control surface. The loading has a logarithmic singularity at the flap edges, which may be determined directly by the method of matched asymptotic expansions. Expressions are given for the singular flap loading for various flap hinge line and side edge geometries, both for steady and unsteady flap deflection. The regular part of the flap loading must be obtained by inverting the lifting-surface-theory integral equation relating the pressure and the downwash on the wing: procedures are described to accomplish this for a general wing and flap geometry. The method is applied to several example wings, and the results are compared with experimental data. Theory and test correlate well.

  11. [Clinical experience with the supraclavicular flap to reconstruct head and neck defects].

    PubMed

    Zhang, Bin; Yan, Dangui; Zhang, Yabing; Zhang, Xiwei; Wan, Hanfeng

    2015-06-01

    To evaluate the efficacy of pedicled supraclavicular artery island flaps for head and neck reconstruction. Reconstructive surgeries for head and neck oncologic defects were performed with the pedicled supraclavicular artery island flaps in 10 patients from May 2013 to December 2014 and the cases were review. Among them, 6 were performed for hypopharyngeal cancer, 2 for oral tongue cancer, 1 for oral base cancer and 1 for cervical esophageal cancer. The size of the flaps was measured in (5-8) cm × (6-12) cm. Seven flaps survived, one flap failured and two flaps had partial necrosis. Donor sites were closed primarily without morbidity. The pedicled supraclavicular artery island flap is an easy harvesting and reliable for head and neck reconstruction, especially suitable for otolaryngo-head and neck surgeon and maxillofacial surgeon in the local hospital.

  12. Hypersonic and transonic buzz measurements on the lower pitch flap of the M2-F2 lifting entry configuration

    NASA Technical Reports Server (NTRS)

    Warner, R. W.; Wilcox, P. R.

    1972-01-01

    Free-oscillation damping measurements at hypersonic and transonic Mach numbers are presented for the lower pitch flap of the M2-F2 reentry vehicle. For the flow and model conditions tested, the damping measurements indicate the absence of hypersonic buzz instability for flap rotation frequencies of 47.3 Hz, 153 Hz, and 360 Hz, the presence of transonic buzz for 47.3 Hz flap, and the absence of transonic buzz for a 115 Hz flap. There are not enough flap damping data for an error estimate based on repeatability, but a partial damping calibration is presented in which an analog computer simulation of random flap response for a known flap damping is fed into the autocorrelation computer and filter combination used for most of the damping measurements.

  13. Development of a morphing flap using shape memory alloy actuators: the aerodynamic characteristics of a morphing flap

    NASA Astrophysics Data System (ADS)

    Ko, Seung-Hee; Bae, Jae-Sung; Rho, Jin-Ho

    2014-07-01

    The discontinuous contour of a wing with conventional flaps diminishes the aerodynamic performance of an aircraft. A wing with a continuous contour does not experience extreme flow stream fluctuations during flight, and consequently has good aerodynamic characteristics. In this study, a morphing flap using shape memory alloy actuators is proposed, designed and fabricated, and its aerodynamic characteristics are investigated using aerodynamic analyses and wind tunnel tests. The ribs of the morphing flap are designed and fabricated with multiple elements joined together in a way that allows relative rotations of adjacent elements and forms a smooth contour of the morphing flap. The aerodynamic analyses of this multiple-element morphing-flap wing are performed using XFLR pro; its aerodynamic performance is compared with that of a mechanical-flap wing, and is measured through wind-tunnel tests.

  14. Static investigation of a two-dimensional convergent-divergent exhaust nozzle with multiaxis thrust-vectoring capability

    NASA Technical Reports Server (NTRS)

    Taylor, John G.

    1990-01-01

    An investigation was conducted in the Static Test Facility of the NASA Langley 16-Foot Transonic Tunnel to determine the internal performance of two-dimensional convergent-divergent nozzles designed to have simultaneous pitch and yaw thrust vectoring capability. This concept utilized divergent flap rotation of thrust vectoring in the pitch plane and deflection of flat yaw flaps hinged at the end of the sidewalls for yaw thrust vectoring. The hinge location of the yaw flaps was varied at four positions from the nozzle exit plane to the throat plane. The yaw flaps were designed to contain the flow laterally independent of power setting. In order to eliminate any physical interference between the yaw flap deflected into the exhaust stream and the divergent flaps, the downstream corners of both upper and lower divergent flaps were cut off to allow for up to 30 deg of yaw flap deflection. The impact of varying the nozzle pitch vector angle, throat area, yaw flap hinge location, yaw flap length, and yaw flap deflection angle on nozzle internal performance characteristics, was studied. High-pressure air was used to simulate jet exhaust at nozzle pressure ratios up to 7.0. Static results indicate that configurations with the yaw flap hinge located upstream of the exit plane provide relatively high levels of thrust vectoring efficiency without causing large losses in resultant thrust ratio. Therefore, these configurations represent a viable concept for providing simultaneous pitch and yaw thrust vectoring.

  15. Non-invasive terahertz imaging of tissue water content for flap viability assessment

    PubMed Central

    Bajwa, Neha; Au, Joshua; Jarrahy, Reza; Sung, Shijun; Fishbein, Michael C.; Riopelle, David; Ennis, Daniel B.; Aghaloo, Tara; St. John, Maie A.; Grundfest, Warren S.; Taylor, Zachary D.

    2016-01-01

    Accurate and early prediction of tissue viability is the most significant determinant of tissue flap survival in reconstructive surgery. Perturbation in tissue water content (TWC) is a generic component of the tissue response to such surgeries, and, therefore, may be an important diagnostic target for assessing the extent of flap viability in vivo. We have previously shown that reflective terahertz (THz) imaging, a non-ionizing technique, can generate spatially resolved maps of TWC in superficial soft tissues, such as cornea and wounds, on the order of minutes. Herein, we report the first in vivo pilot study to investigate the utility of reflective THz TWC imaging for early assessment of skin flap viability. We obtained longitudinal visible and reflective THz imagery comparing 3 bipedicled flaps (i.e. survival model) and 3 fully excised flaps (i.e. failure model) in the dorsal skin of rats over a postoperative period of 7 days. While visual differences between both models manifested 48 hr after surgery, statistically significant (p < 0.05, independent t-test) local differences in TWC contrast were evident in THz flap image sets as early as 24 hr. Excised flaps, histologically confirmed as necrotic, demonstrated a significant, yet localized, reduction in TWC in the flap region compared to non-traumatized skin. In contrast, bipedicled flaps, histologically verified as viable, displayed mostly uniform, unperturbed TWC across the flap tissue. These results indicate the practical potential of THz TWC sensing to accurately predict flap failure 24 hours earlier than clinical examination. PMID:28101431

  16. Use of inferior gluteal artery and posterior thigh perforators in management of ischial pressure sores with limited donor sites for flap coverage.

    PubMed

    Unal, Cigdem; Ozdemir, Jale; Yirmibesoglu, Oktay; Yucel, Ergin; Agir, Hakan

    2012-07-01

    Reconstructive surgery for ischial pressure sore defects presents a challenge because of high rates of recurrence. The aim of this study was to describe the use of inferior gluteal artery (IGA) and posterior thigh perforators in management of ischial pressure sores with limited donor sites. Between September 2005 and 2009, 11 patients (9 male, 2 female) with ischial sores were operated by using IGA and posterior thigh perforator flaps. The data of patients included age, sex, cause of paraplegia, flap size, perforator of flap, previous surgeries, recurrences, complications, and postoperative follow-up. Nine IGA and 5 posterior thigh perforator flaps were used. Six patients presented with recurrent lesions, 5 patients were operated for sacral and contralateral ischial pressure sores previously. In 2 patients, IGA and posterior thigh perforator flaps were used in combination. Patients were followed for an average of 34.3 months. In 2 recurrent cases, readvancement of IGA perforator flap and gluteus maximus myocutaneous flap were treatment of choice. Treatment of patients with recurrent lesions or multiple pressure sores is challenging because of limited available flap donor sites. In this study, posterior thigh perforator flaps were preferred in patients in whom the previous donor site was the gluteal region. IGA perforator flaps were the treatment of choice in patients for whom posterior thigh region was previously used. Alternately, preserved perforators of previous conventional myocutaneous flaps enabled us to use these perforators in recurrences.

  17. Logarithmic spiral flap for circular or oval defects on the lateral surface of the nose and nasal ala: a series of 15 cases.

    PubMed

    Moreno-Artero, E; Redondo, P

    2015-10-01

    A large number of flaps, particularly rotation and transposition flaps, have been described for the closure of skin defects left by oncologic surgery of the nose. The logarithmic spiral flap is a variant of the rotation flap. We present a series of 15 patients with different types of skin tumor on the nose. The skin defect resulting from excision of the tumor by micrographic surgery was reconstructed using various forms of the logarithmic spiral flap. There are 3 essential aspects to flap design: commencement of the pedicle at the upper or lower border of the wound, a width of the distal end of the flap equal to the vertical diameter of the defect, and a progressive increase in the radius of the spiral from the distal end of the flap to its base. The cosmetic and functional results of surgical reconstruction were satisfactory, and no patient required additional treatment to improve scar appearance. The logarithmic spiral flap is useful for the closure of circular or oval defects situated on the lateral surface of the nose and nasal ala. The flap initiates at one of the borders of the wound as a pedicle with a radius that increases progressively to create a spiral. We propose the logarithmic spiral flap as an excellent option for the closure of circular or oval defects of the nose. Copyright © 2015 Elsevier España, S.L.U. and AEDV. All rights reserved.

  18. Comparison of morbidity-related seroma formation following conventional latissimus dorsi flap versus muscle-sparing latissimus dorsi flap breast reconstruction

    PubMed Central

    Numajiri, Toshiaki; Nakatsukasa, Katsuhiko; Sakaguchi, Koichi; Taguchi, Tetsuya

    2017-01-01

    Purpose The pedicled, descending-branch muscle-sparing latissimus dorsi (MSLD) flap has been widely used for breast reconstruction following total mastectomy. However, the superiority of the MSLD flap compared to the conventional latissimus dorsi (CLD) flap in preventing seroma formation has not been demonstrated. This study compares the morbidities related to seroma formation following pedicled MSLD flap and CLD flap breast reconstruction. Methods A total of 15 women who underwent partial mastectomy and immediate partial breast reconstruction with MSLD flaps were compared with 15 women under identical conditions with CLD flap breast reconstruction. The medical records were reviewed for both complications and demographic data. The authors compared morbidity, including donor-site seroma, total volume of drain discharge, indwelling period of drainage, and length of hospital stay following both MSLD flap and CLD flap breast reconstruction. Results The demographic data of the 2 groups were not significantly different. Donor-site seroma occurred in 2 MSLD patients (13.3%) and in 6 CLD patients (40.0%). The total volume of the drain discharge and the indwelling period of drainage at donor site were significantly lower in the MSLD group. The length of hospital stay was significantly shorter (by approximately a day and a half) for the MSLD group. Conclusion The MSLD flap, with its low complication rate and associated minimal functional and aesthetic deficits at the donor site, may be a useful option for small breast reconstruction if earlier discharge from hospital is demanded. PMID:28932726

  19. Comparison of morbidity-related seroma formation following conventional latissimus dorsi flap versus muscle-sparing latissimus dorsi flap breast reconstruction.

    PubMed

    Sowa, Yoshihiro; Numajiri, Toshiaki; Nakatsukasa, Katsuhiko; Sakaguchi, Koichi; Taguchi, Tetsuya

    2017-09-01

    The pedicled, descending-branch muscle-sparing latissimus dorsi (MSLD) flap has been widely used for breast reconstruction following total mastectomy. However, the superiority of the MSLD flap compared to the conventional latissimus dorsi (CLD) flap in preventing seroma formation has not been demonstrated. This study compares the morbidities related to seroma formation following pedicled MSLD flap and CLD flap breast reconstruction. A total of 15 women who underwent partial mastectomy and immediate partial breast reconstruction with MSLD flaps were compared with 15 women under identical conditions with CLD flap breast reconstruction. The medical records were reviewed for both complications and demographic data. The authors compared morbidity, including donor-site seroma, total volume of drain discharge, indwelling period of drainage, and length of hospital stay following both MSLD flap and CLD flap breast reconstruction. The demographic data of the 2 groups were not significantly different. Donor-site seroma occurred in 2 MSLD patients (13.3%) and in 6 CLD patients (40.0%). The total volume of the drain discharge and the indwelling period of drainage at donor site were significantly lower in the MSLD group. The length of hospital stay was significantly shorter (by approximately a day and a half) for the MSLD group. The MSLD flap, with its low complication rate and associated minimal functional and aesthetic deficits at the donor site, may be a useful option for small breast reconstruction if earlier discharge from hospital is demanded.

  20. Anatomical explanations for acute depressions in radial pattern of axial sap flow in two diffuse-porous mangrove species: implications for water use.

    PubMed

    Zhao, Hewei; Yang, Shengchang; Guo, Xudong; Peng, Congjiao; Gu, Xiaoxuan; Deng, Chuanyuan; Chen, Luzhen

    2018-02-01

    Mangrove species have developed uniquely efficient water-use strategies in order to survive in highly saline and anaerobic environments. Herein, we estimated the stand water use of two diffuse-porous mangrove species of the same age, Sonneratia apetala Buch. Ham and Sonneratia caseolaris (L.) Engl., growing in a similar intertidal environment. Specifically, to investigate the radial patterns of axial sap flow density (Js) and understand the anatomical traits associated with them, we measured axial sap flow density in situ together with micromorphological observations. A significant decrease of Js was observed for both species. This result was accompanied by the corresponding observations of wood structure and blockages in xylem sapwood, which appeared to influence and, hence, explained the acute radial reductions of axial sap flow in the stems of both species. However, higher radial resistance in sapwood of S. caseolaris caused a steeper decline of Js radially when compared with S. apetala, thus explaining the latter's more efficient use of water. Without first considering acute reductions in Js into the sapwood from the outer bark, a total of ~55% and 51% of water use would have been overestimated, corresponding to average discrepancies in stand water use of 5.6 mm day-1 for S. apetala trees and 2.5 mm day-1 for S. caseolaris trees. This suggests that measuring radial pattern of Js is a critical factor in determining whole-tree or stand water use. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Comparison of the deep inferior epigastric perforator flap and free transverse rectus abdominis myocutaneous flap in postmastectomy reconstruction: a cost-effectiveness analysis.

    PubMed

    Thoma, Achilleas; Veltri, Karen; Khuthaila, Dana; Rockwell, Gloria; Duku, Eric

    2004-05-01

    This study compared the deep inferior epigastric perforator (DIEP) flap and the free transverse rectus abdominis myocutaneous (TRAM) flap in postmastectomy reconstruction using a cost-effectiveness analysis. A decision analytic model was used. Medical costs associated with the two techniques were estimated from the Ontario Ministry of Health Schedule of Benefits for 2002. Hospital costs were obtained from St. Joseph's Healthcare, a university teaching hospital in Hamilton, Ontario, Canada. The utilities of clinically important health states related to breast reconstruction were obtained from 32 "experts" across Canada and converted into quality-adjusted life years. The probabilities of these various clinically important health states being associated with the DIEP and free TRAM flaps were obtained after a thorough review of the literature. The DIEP flap was more costly than the free TRAM flap ($7026.47 versus $6508.29), but it provided more quality-adjusted life years than the free TRAM flap (28.88 years versus 28.53 years). The baseline incremental cost-utility ratio was $1464.30 per quality-adjusted life year, favoring adoption of the DIEP flap. Sensitivity analyses were performed by assuming that the probabilities of occurrence of hernia, abdominal bulging, total flap loss, operating room time, and hospital stay were identical with the DIEP and free TRAM techniques. By assuming that the probability of postoperative hernia for the DIEP flap increased from 0.008 to 0.054 (same as for TRAM flap), the incremental cost-utility ratio changed to $1435.00 per quality-adjusted life year. A sensitivity analysis was performed for the complication of hernia because the DIEP flap allegedly diminishes this complication. Increasing the probability of abdominal bulge from 0.041 to 0.103 for the DIEP flap changed the ratio to $2731.78 per quality-adjusted life year. When the probability of total flap failure was increased from 0.014 to 0.016, the ratio changed to $1384.01 per quality-adjusted life year. When the time in the operating room was assumed to be the same for both flaps, the ratio changed to $4026.57 per quality-adjusted life year. If the hospital stay was assumed to be the same for both flaps, the ratio changed to $1944.30 per quality-adjusted life year. On the basis of the baseline calculation and sensitivity analyses, the DIEP flap remained a cost-effective procedure. Thus, adoption of this new technique for postmastectomy reconstruction is warranted in the Canadian health care system.

  2. Wind-tunnel free-flight investigation of a 0.15-scale model of the F-106B airplane with vortex flaps

    NASA Technical Reports Server (NTRS)

    Yip, Long P.

    1987-01-01

    An investigation to determine the effects of vortex flaps on the flight dynamic characteristics of the F-106B in the area of low-speed, high-angle-of-attack flight was undertaken on a 0.15-scale model of the airplane in the Langley 30- by 60-Foot Tunnel. Static force tests, dynamic forced-oscillation tests, as well as free-flight tests were conducted to obtain a data base on the flight characteristics of the F-106B airplane with vortex flaps. Vortex flap configurations tested included a full-span gothic flap, a full-span constant-chord flap, and a part-span gothic flap.

  3. A novel animal model for skin flap prelamination with biomaterials

    NASA Astrophysics Data System (ADS)

    Zhou, Xianyu; Luo, Xusong; Liu, Fei; Gu, Chuan; Wang, Xi; Yang, Qun; Qian, Yunliang; Yang, Jun

    2016-09-01

    Several animal models of skin flap construction were reported using biomaterials in a way similar to prefabrication. However, there are few animal model using biomaterials similar to prelamination, another main way of clinical skin flap construction that has been proved to be reliable. Can biomaterials be added in skin flap prelamination to reduce the use of autogenous tissues? Beside individual clinical attempts, animal model is needed for randomized controlled trial to objectively evaluate the feasibility and further investigation. Combining human Acellular Dermal Matrix (hADM) and autologous skin graft, we prelaminated flaps based on inguinal fascia. One, two, three and four weeks later, hADM exhibited a sound revascularization and host cell infiltration. Prelaminated skin flaps were then raised and microsurgically transplanted back to groin region. Except for flaps after one week of prelamination, flaps from other subgroups successfully reconstructed defects. After six to sixteen weeks of transplantation, hADM was proved to being able to maintain its original structure, having a wealth of host tissue cells and achieving full revascularization.To our knowledge, this is the first animal model of prelaminating skin flap with biomaterials. Success of this animal model indicates that novel flap prelamination with biomaterials is feasible.

  4. Reconstruction of Heel With Propeller Flap in Postfasciotomy and Popliteal Artery Revascularization State.

    PubMed

    Kang, Jin Seok; Choi, Hwan Jun; Tak, Min Sung

    2016-06-01

    Free flaps are still the gold standard for large defects of the lower limb, but propeller perforator flaps have become a simpler and faster alternative to free flaps because of some advantages such as reliable vascular pedicle, wide mobilization and rotation, great freedom in design, low donor site morbidity, and easy harvest with no requirement for anastomosis. But when the vessels show insufficient findings in preoperative evaluation using a Doppler probe or the vessel is injured, the surgeon should avoid performing free flap surgery to prevent flap failure and should select a propeller perforator flap as an alternative method on the condition that more than one perforator is intact. In this study, we report reconstruction of soft tissue defects of the heel with a pedicled propeller flap in postfasciotomy and popliteal artery revascularization state by making an incision on the central portion above the Achilles tendon, which can be covered by the posterior tibial artery perforator or the peroneal artery perforator based flaps. In conclusion, we showed that although the popliteal artery was injured, the soft tissue defect can be reconstructed using a perforator propeller flap if intact distal flow in the anastomosis site was confirmed. © The Author(s) 2015.

  5. PubMed Central

    Tewfik, K.; Cassano, L.; Pederneschi, N.; Catanzaro, S.; Manfuso, A.; Cocchi, R.

    2017-01-01

    SUMMARY Free flap surgery is overall considered the gold standard in head and neck reconstruction, with a success rate of 95%. The management of a total flap necrosis and which solution, between a pedicled or a second free flap, is safer for a salvage procedure is still controversial. Object of this study is to describe the authors' management of total free flap loss in head and neck reconstruction and compare the choices and results to those reported in the literature. From January 2012 to January 2016, 149 consecutive free flaps were performed at the Maxillo- Facial Operative Unit of the Hospital Casa Sollievo della Sofferenza in San Giovanni Rotondo (Italy) for reconstruction of head and neck defects. Of these, 6 flaps were lost due to a total necrosis. In 5 cases it was decided to harvest a second free flap, and in the remaining patient a temporalis muscle flap was used. All the free salvage flaps were successful, without complications and with a good aesthetic and functional recovery. Analysing the data obtained, and comparing them with those reported in the literature, it can be concluded that a second subsequent free flap can be considered an ideal and safe procedure in salvage surgery. PMID:29165433

  6. Bed isolation in experimental flap studies in rats: a dispensable procedure.

    PubMed

    Heimer, Sina; Schaefer, Amelia; Mueller, Wolf; Lass, Ulrike; Gebhard, Martha M; Germann, Günter; Leimer, Uwe; Köllensperger, Eva; Reichenberger, Matthias A

    2013-03-01

    Review of the literature regarding rodent experimental flap models reveals fundamental differences in applied surgical procedures. Although some authors isolate the flap from its wound bed, others do not. This study was planned to investigate to what extent the insertion of a silicone sheet affects physiological wound healing in experimental flap surgery. An extended epigastric adipocutaneous flap (6 × 10 cm) was raised in 16 male Lewis rats. In the control group (group C), flaps were immediately inset without any intervention. In the experimental group (group M), a silicone sheet barrier was placed between the flap and the wound bed. Mean flap survival area and flap perfusion were evaluated. Microvessel density was visualized by immunohistochemistry, and semiquantitative real-time polymerase chain reaction addressed differential gene expression. All animals were investigated on postoperative day 5. Flap survival area and flap perfusion were found to be similar. Immunohistochemistry, however, demonstrated a significantly increased number of CD31-positive small vessels in group C. The insertion of the silicone sheet barrier (group M) was accompanied by a significantly enhanced expression of proinflammatory genes and a suppression of proangiogenic genes. Our results show that although the silicone membrane has no influence on the surgical outcome in terms of flap survival and perfusion, it does lead to significant molecular alterations in pathways involved in physiological wound healing. These alterations are artificially induced by the foreign body material and conceal the true driving forces of the healing process. As the latter might include relevant therapeutic targets to ameliorate surgical results, we regard wound bed isolation as a dispensable procedure in the study of rodent flap models.

  7. Reconstruction of a traumatic plantar foot defect with a novel free flap: The medial triceps brachii free flap.

    PubMed

    Leclère, Franck Marie; Casoli, Vincent

    2015-01-01

    Lower extremity defects may account for 14.6% of the approximately 117 million visits to emergency departments in the U. S. in 2007. In this article, we present a reconstruction of a traumatic plantar foot defect with a medial triceps brachii (MTB) free flap. A 53-year-old man sustained an accidental gunshot wound to the right foot. The patient was admitted after the failure of a sural flap procedure performed in another hospital. He presented with a soft-tissue defect with calcaneal exposition and osteomyelitis. The defect was reconstructed with a MTB free flap anastomosed to his dorsalis pedis vessels. Flap raising time was 52 min. There were no intraoperative complications. The total flap surface was 38.5 cm². The pedicle length was 3 cm. The diameters of the artery and vein of the flap pedicle were 1.1 mm and 1.4 mm, respectively. Ischemia time was 28 min. His donor site healed uneventfully without any morbidity, and the scar was well concealed. The flaps survived and there was no partial flap necrosis. A split-thickness skin graft was performed 12 days postoperatively. Two months later, he had a completely healed wound with no contour abnormality. The total follow-up was 24 months. The patient was able to walk normally. MTB free flap appears to be an excellent option for plantar foot defects in patients with preserved vascularization of the foot. Due to the anatomical shape of the flap, the position of its pedicle, and the moldability of the muscle, we predict that the use of the MTB free flap will grow and develop rapidly for reconstruction of ankle and foot defects.

  8. Posterior trunk reconstruction with the dorsal intercostal artery perforator based flap: Clinical experience on 20 consecutive oncological cases.

    PubMed

    Brunetti, Beniamino; Tenna, Stefania; Aveta, Achille; Poccia, Igor; Segreto, Francesco; Cerbone, Vincenzo; Persichetti, Paolo

    2016-10-01

    Few studies in the recent literature have investigated the reliability of dorsal intercostal artery perforator (DICAP) flap in posterior trunk reconstruction. The purpose of this report is to describe our clinical experience with the use of DICAP flaps in a cohort of oncological patients. Twenty patients underwent posterior trunk reconstruction with DICAP based flaps. Patients age ranged from 45 to 76 years. All defects resulted from skin cancer ablation. Defect sizes ranged from 4 × 4 to 6 × 8 cm. The flaps were mobilized in V-Y or propeller fashion. The flaps were islanded on 1 (12 cases), 2 (6 cases), or 3 (2 cases) perforators. Donor sites were always closed primarily. Eleven V-Y advancement flaps were performed; one of these was converted to a perforator-plus peninsular flap design, which retained an additional source of blood supply from the opposite skin bridge. Nine flaps were mobilized in propeller fashion. Flap dimensions ranged from 4 × 6 to 6 × 14 cm. Mean operative time was 70 min. One V-Y flap complicated with marginal necrosis that healed with no need for reintervention. All the other flaps survived uneventfully. No other complications were observed at recipient and donor sites. Follow-up ranged from 3 months to 2 years. All the patients were satisfied with the surgical outcome. DICAP based flaps proved to be a reliable option to resurface posterior trunk defects following oncological resection, allowing to achieve like-with-like reconstruction with excellent contour and minimal donor-site morbidity. © 2015 Wiley Periodicals, Inc. Microsurgery 36:546-551, 2016. © 2015 Wiley Periodicals, Inc.

  9. Venous coupler use for free-flap breast reconstructions: specific analyses of TMG and DIEP flaps.

    PubMed

    Bodin, Frédéric; Brunetti, Stefania; Dissaux, Caroline; Erik, A Sauleau; Facca, Sybille; Bruant-Rodier, Catherine; Liverneaux, Philippe

    2015-05-01

    The purpose of this report was to present the results of comparisons of anastomotic data and flap complications in the use of venous coupler in breast reconstruction with the transverse musculocutaneous gracilis (TMG) flap and the deep inferior epigastric perforator (DIEP) flap. Over a three-year period, 95 patients suffering from breast cancer were treated with mastectomy and breast reconstruction using free flaps. We performed 121 mechanical venous anastomoses for 105 flap procedures (80 DIEP and 25 TMG). The coupler size, anastomotic duration, number of anastomoses and postoperative complications were assessed for the entire series. The coupling device was perfectly suitable for all end-to-end anastomoses between the vein(s) of the flap and the internal mammary vein(s). No venous thrombosis occurred. The mean anastomotic time did not significantly differ between the DIEP (330 seconds) and TMG flap procedures (352 seconds) (P = 0.069). Additionally, there were no differences in coupling time observed following a comparison of seven coupler sizes (P = 0.066). The mean coupler size used during the TMG flap procedure was smaller than that used with the DIEP (2.4 mm versus 2.8 mm) (P < 0.001). The mean size was also smaller when double venous anastomoses were required compared to single anastomosis (2.4 mm versus 2.9 mm) (P < 0.001). The double branching was more frequent with the TMG flap (28%) than with the DIEP flap (11%). The coupler size used was smaller for the TMG procedure and when double venous anastomosis was performed. Additionally, anastomotic time was not affected by the flap type or coupler size used or by anastomosis number. © 2014 Wiley Periodicals, Inc.

  10. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).

    PubMed

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.

  11. Comparison of laser in situ keratomileusis flaps created by 2 femtosecond lasers.

    PubMed

    Zheng, Yan; Zhou, Yuehua; Zhang, Jing; Liu, Qian; Zhai, Changbin; Wang, Yonghua

    2015-03-01

    To compare flap morphology created by the WaveLight FS200 femtosecond laser and the VisuMax femtosecond laser, assessing the uniformity, accuracy, and predictability of flap creation. A total of 400 eyes had corneal flaps created with the WaveLight FS200 femtosecond laser (200 eyes) or the VisuMax femtosecond laser (200 eyes). The desired flap thickness was 110 μm. At 1 week postoperatively, all eyes were evaluated with RTVue Fourier-domain optical coherence tomography. Dimensions of the flaps were tested for their regularity, uniformity, accuracy, and predictability comparison. One week after surgery, the central flap thickness and the mean flap thickness of the FS200 group were 105.4 ± 3.4 μm and 105.7 ± 2.6 μm, respectively. They were both thinner than those of the VisuMax group, which were 110.8 ± 3.9 μm and 111.3 ± 2.3 μm, respectively. The mean deviation between the achieved and attempted flap thickness of the FS200 group (5.2 ± 1.9 μm) was greater than that of the VisuMax group (3.2 ± 1.8 μm). Flap thickness measurements at 36 points in both groups were close to the intended thickness. Morphology of the flaps in the 0-, 45-, 90-, and 135-degree lines created by the FS200 femtosecond laser and VisuMax femtosecond laser were uniform and regular. Flap dimensions created by the WaveLight FS200 femtosecond laser and VisuMax femtosecond laser were uniform and regular. Although the flap thickness created by the FS200 was less than that created by the VisuMax, measurements of both femtosecond lasers were close to the intended thickness.

  12. Pharmacologic manipulation of the microcirculation in cutaneous and myocutaneous flaps in pigs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pang, C.Y.; Neligan, P.C.; Nakatsuka, T.

    1985-04-01

    The vascular effects of isoxsuprine, diazoxide, and isoproterenol were studied in arterial buttock flaps and latissimus dorsi myocutaneous flaps in pigs. Capillary blood flow to the skin and muscles of these flaps was measured by the radioactive microsphere (15-mu diameter) technique 6 hours postoperatively under pentobarbital anesthesia. It was observed that isoproterenol, a beta-adrenergic receptor agonist, was not effective in augmentation of skin blood flow in the arterial buttock flaps. However, isoproterenol significantly increased capillary blood flow to the arterialized portion of latissimus dorsi myocutaneous flaps compared with controls. Isoxsuprine and diazoxide (vascular smooth muscle relaxants) significantly (p less thanmore » 0.05) increased total capillary blood flow to the skin of arterial buttock flaps and to the skin and muscles of the latissimus dorsi myocutaneous flaps. However, the increase in capillary blood flow occurred mainly in the arterialized portion of these flaps. The capillary blood flow, which was supplied by the small arteries in the distal portion of the arterial buttock and latissimus dorsi flaps, was not increased by treatment with isoxsuprine or diazoxide. Therefore, there was also no increase in the maximum distance of capillary blood flow from the pedicle to the distal end of the flaps. These observations led the authors to hypothesize that different sizes (diameters) of arteries in the skin and muscle have different reactivity (or sensitivity) to vasodilatory drugs. In the present experiment, the large dominant artery of the arterial buttock and latissimus dorsi flaps responded to isoxsuprine or diazoxide (vascular smooth-muscle relaxants), resulting in an increase in blood supply to the capillaries in the proximal portion of the flaps.« less

  13. Skin flaps and grafts - self-care

    MedlinePlus

    ... Free flap - self-care; Skin autografting - self-care; Pressure ulcer skin flap self-care; Burns skin flap self- ... skin infection Surgery for skin cancer Venous ulcers , pressure ulcers , or diabetic ulcers that DO NOT heal After ...

  14. Space Shuttle Body Flap Actuator Bearing Testing for NASA Return to Flight

    NASA Technical Reports Server (NTRS)

    Jet, Timothy R.; Predmore, Roamer E.; Dube, Michael; Jones, William R., Jr.

    2006-01-01

    The Space Shuttle body flap (BF) is located beneath the main engine nozzles and is required for proper aerodynamic control during orbital descent. The body flap is controlled by four actuators connected by a common shaft and driven by the hydraulic power drive unit. Inspection of the actuators during refurbishment revealed three shaft bearings with unexpected damage. One was coated with black oxide on the balls and race wear surfaces, a second contained a relatively deep wear scar, and the third with scratches and an aluminum particle in the wear track. A shaft bearing life test program was initiated to measure the wear life and explain the 5.08-micrometer wear scar. A tribological analysis was conducted to demonstrate that the black oxide coated wear surfaces did not damage the bearing, interfere with the lubrication, or cause severe bearing wear. Pre-damaged (equivalent of 30 missions), commercial equivalent bearings and previously flown shaft bearings were tested at axial loads, speeds, and temperatures seen during flight operations. These bearing were successfully life tested at 60 C for 24 hours or 90 flights. With a safety factor of 4X, the bearings were qualified for 22 flights when only a maximum of 12 flights are expected. Additional testing at 23 C was performed to determine the lubricant life and to further understand the mechanism that caused the blackened balls. Test results indicating bearing life was shortened at a lower temperature surprised the investigators. Start\\Stop bearing testing that closely simulates mission profile was conducted at 23 C. Results of this testing showed lubricant life of 12 flights including a safety factor of four. Additional testing with bearings that have the equivalent of 30 missions of damage is being tested at 23 C. These tests are being performed over the Shuttle load profile to demonstrate the residual bearing life in the actuators exceeds 12 missions. Testing showed that the end of the shaft bearing life was characterized by bearing temperature rise, preload drop, and the onset of a severe wear bearing failure mechanism. The severe wear failure mechanism is characterized by rough wear scars, extensive bearing wear and steel transfer between the balls and the races.

  15. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation.

    PubMed

    Radu, Maria D; Räber, Lorenz; Heo, Jungho; Gogas, Bill D; Jørgensen, Erik; Kelbæk, Henning; Muramatsu, Takashi; Farooq, Vasim; Helqvist, Steffen; Garcia-Garcia, Hector M; Windecker, Stephan; Saunamäki, Kari; Serruys, Patrick W

    2014-01-22

    Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections--particularly non-flow-limiting--compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline. OCT-detected edge dissections which are angiographically silent in the majority of cases are not associated with acute stent thrombosis or restenosis up to one-year follow-up.

  16. Pre-expanded Intercostal Perforator Super-Thin Skin Flap.

    PubMed

    Liao, Yunjun; Luo, Yong; Lu, Feng; Hyakusoku, Hiko; Gao, Jianhua; Jiang, Ping

    2017-01-01

    This article introduces pre-expanded super-thin intercostal perforator flaps, particularly the flap that has a perforator from the first to second intercostal spaces. The key techniques, advantages and disadvantages, and complications and management of this flap are described. At present, the thinnest possible flap is achieved by thinning the pre-expanded flap that has a perforator from the first to second intercostal spaces. It is used to reconstruct large defects on the face and neck, thus restoring function and cosmetic appearance. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    PubMed Central

    Thankappan, Krishnakumar; Trivedi, Nirav P.; Sharma, Mohit; Kuriakose, Moni A.; Iyer, Subramania

    2009-01-01

    A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome. PMID:19881028

  18. Ipsilateral pedicled TRAM flaps: the safer alternative?

    PubMed

    Clugston, P A; Gingrass, M K; Azurin, D; Fisher, J; Maxwell, G P

    2000-01-01

    Transverse rectus abdominis myocutaneous (TRAM) flap breast reconstruction has become a commonly performed procedure in the 1990s. The original description of the procedure was that of an ipsilaterally based pedicle procedure. Concerns about potential folding of the pedicle with possible compromise of the vascular supply led many surgeons to prefer the contralateral pedicle. Subsequently, there have been several large clinical series of pedicled TRAM flaps showing a relatively high complication rate related to flap vascularity problems. Partial flap necrosis rates in pedicled TRAM series range from 5 to 44 percent. These findings resulted in many centers favoring free TRAM flap breast reconstruction, despite an increase in resource use and negligible differences in complication rates. Ipsilateral pedicle TRAM flap breast reconstruction is not a commonly reported procedure and is reserved for cases for which scars preclude use of the contralateral pedicle. Simplicity and versatility of flap shaping, improved maintenance of the inframammary fold, and lack of disruption of the natural xiphoid hollow give ipsilateral TRAM flaps further advantages. This study reports on a series of 252 consecutive ipsilateral TRAM flap reconstructions in 190 patients. The majority of patients underwent muscle-sparing procedures with preservation of a medial and a lateral strip of rectus muscle. Immediate reconstruction was done in 104 of the 190 patients. Skin-sparing (69 patients) or skin-reduction procedures (21 patients) were used in 90 of the 104 patients (87 percent) undergoing immediate reconstruction. Complication rates were comparable to those of series reported for contralateral TRAM flaps, except that partial flap necrosis (2.0 percent) was less in this series. Risk factors were analyzed with regard to the most common complications seen in this study. Ipsilateral TRAM flap breast reconstruction is our preferred method, if available, because we believe that it has several advantages over the contralateral pedicled TRAM and this report suggests a lower partial flap necrosis rate than previously reported.

  19. Prevertebral corridor: posterior pathway for reconstruction of the ventral skull base.

    PubMed

    Durmaz, Abdullah; Fernandez-Miranda, Juan; Snyderman, Carl H; Rivera-Serrano, Carlos; Tosun, Fuat

    2011-05-01

    Regional vascularized flaps, such as the pericranial and temporoparietal fascia flaps, are currently used for reconstruction of skull base defects after endoscopic endonasal surgery whenever local vascularized flaps, such as the nasoseptal flap, are not available. Two different transposition pathways, infratemporal transpterygoid and subfrontal, have been proposed for regional flaps. The objective of this study was to describe and assess the feasibility of the transposition of a vascularized pedicled flap from the occipital galeopericranium via the prevertebral space corridor into the nasopharynx. Ten heads were injected with colored silicone. An endoscopic endonasal anterior craniofacial resection and panclival approach were performed in each specimen. The occipital flap was harvested using a previously described technique. The prevertebral corridor, extending from the neck to the nasopharynx, was dissected superficial to the paraspinal muscles. Computed tomography-based image guidance was used to assess the relationship between the corridor and adjacent neurovascular structures. Length of the corridor and pedicle and area of the donor flap were measured. The flap was harvested and successfully transposed into the nasopharynx using the proposed corridor in all studied specimens (10 heads, 20 sides). All flaps provided complete coverage of the skull base defects. The average length of the pedicle was 70.5 (SD, 6.5) mm, and the average length and width of the flap were 99.9 (SD, 14.6) mm and 59.3 (SD, 10.9) mm, respectively. The average length of the prevertebral corridor was 49.7 (SD, 4.8) mm. The occipital flap has favorable anatomic characteristics for use in skull base reconstruction. Transposition of the flap via the prevertebral corridor is a suitable option for vascularized reconstruction of expanded endonasal skull base defects when other local or regional flaps are not available. Additional clinical studies are necessary to define its role in endoscopic endonasal surgery.

  20. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    PubMed

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is required to assess the clinical benefit of repair. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Abdominal- versus thigh-based reconstruction of perineal defects in patients with cancer.

    PubMed

    Pang, John; Broyles, Justin M; Berli, Jens; Buretta, Kate; Shridharani, Sachin M; Rochlin, Danielle H; Efron, Jonathan E; Sacks, Justin M

    2014-06-01

    An abdominoperineal resection is an invasive procedure that leaves the patient with vast pelvic dead space. Traditionally, the vertical rectus abdominus myocutaneous flap is used to reconstruct these defects. Oftentimes, this flap cannot be used because of multiple ostomy placements or previous abdominal surgery. The anterolateral thigh flap can be used; however, the efficacy of this flap has been questioned. We report a single surgeon's experience with perineal reconstruction in patients with cancer with the use of either the vertical rectus abdominus myocutaneous flap or the anterolateral thigh flap to demonstrate acceptable outcomes with either repair modality. From 2010 to 2012, 19 consecutive patients with perineal defects secondary to cancer underwent flap reconstruction. A retrospective chart review of prospectively entered data was conducted to determine the frequency of short-term and long-term complications. This study was conducted at an academic, tertiary-care cancer center. Patients in the study were patients with cancer who were receiving perineal reconstruction. Interventions were surgical and included either abdomen- or thigh-based reconstruction. The main outcome measures included infection, flap failure, length of stay, and time to radiotherapy. Of the 19 patients included in our study, 10 underwent anterolateral thigh flaps and 9 underwent vertical rectus abdominus myocutaneous flaps for reconstruction. There were no significant differences in demographics between groups (p > 0.05). Surgical outcomes and complications demonstrated no significant differences in the rate of infection, hematoma, bleeding, or necrosis. The mean length of stay after reconstruction was 9.7 ± 3.4 days (± SD) in the anterolateral thigh flap group and 13.4 ± 7.7 days in the vertical rectus abdominus myocutaneous flap group (p > 0.05). The limitations of this study include a relatively small sample size and retrospective evaluation. This study suggests that the anterolateral thigh flap is an acceptable alternative to the vertical rectus abdominus myocutaneous flap for perineal reconstruction (see Video, Supplemental Digital Content 1, http://links.lww.com/DCR/A134).

  2. Perforator flap based on the third perforator of the profunda femoris artery (PFA)-assisted closure of the free vertical posteromedial thigh (vPMT) flap donor site.

    PubMed

    Scaglioni, Mario F; Barth, Andrè A; Chen, Yen-Chou

    2018-06-19

    The primary closure of the vertical posteromedial thigh (vPMT) free flap donor site is very important to minimize donor site morbidity and maximize cosmetic appearance. However, sometimes due to the dimension of the defect, a vPMT flap is wider than the 8-10 cm requirement. The authors report their experience with the third perforator of the profunda femoris artery (PFA) during the vPMT free flap donor-site closure. Between January 2016 and December 2017, 5 patients underwent reconstruction of lower extremity (2 pts.) and head and neck (3 pts.) area with the free vPMT flaps. Attempts to close the vPMT free flap donor site directly failed due to the flaps' width (average: 11 cm) and pedicled perforator flaps based on the third perforator of the PFA at the distal thigh were harvested to close the defect primary without the use of a skin graft. The size of perforator flap based on 3rd perforator of PFA was on average 6 cm × 4 cm (ranged: 4-8 cm × 3-6 cm). In all patients, the third perforator of the PFA was identified and the perforator diameter was on average 2.0 mm (range, 1.8-2.2 mm). All perforators were musculocutaneous and single. The dimensions of the flaps were on average 6 cm × 4 cm (range: 4 to 8 cm × 3 to 6 cm). All flaps healed uneventfully without complications and the patients were satisfied with cosmetic and functional results at 6 months follow-up. The third perforator of the PFA may be an option to ensure primary closure of the PMT flap donor site, when a larger flap for reconstruction is needed with subsequent impossibility to achieve primary closure of the donor site. © 2018 Wiley Periodicals, Inc.

  3. Color Doppler Sonographic and Cadaveric Study of the Arterial Vascularity of the Lateral Upper Arm Flap.

    PubMed

    Sun, Ruimei; Ding, Yu; Sun, Chuanzheng; Li, Xiaojiang; Wang, Jinde; Li, Lei; Yang, Jie; Ren, Yanxin; Zhong, Zhaoming

    2016-04-01

    To determine the importance of adequate preoperative assessment with color Doppler sonography to assist in the successful transfer of lateral upper arm flaps by studying the lateral upper arm flap with color Doppler sonography and analyzing the anatomic features of the radial collateral artery. A clinical case-control study was performed. The radial collateral artery was studied with color Doppler sonography in 15 healthy volunteers. The origins, courses, variations, and locations of the perforators of the radial collateral artery were recorded. The results and data from the color Doppler sonographic investigation were compared with an anatomic study that was performed on 22 adult cadaveric upper limb specimens. The volunteer group (14 of 15 volunteers) and the cadaveric group (19 of 22 upper arm specimens) clearly showed that the branch pattern of the arterial supply was as follows: brachial artery → deep brachial artery → radial collateral artery → posterior radial collateral artery → myocutaneous perforator. Variations in the origin of the radial collateral artery were identified in 1 volunteer bilaterally and in 3 upper arm specimens. The diameters of the artery and vein measured at the distal insertion of the deltoid and the origin of the deep brachial artery were not significantly different between the volunteer and cadaver groups (P > .05). Due to the difference in measuring methods, the length of the vascular pedicles was significantly different between the groups (P < .05). Color Doppler sonography can facilitate the preoperative assessment of the origin, course, variations, and locations of the radial collateral artery and therefore may increase the success rate of lateral upper arm flap transfer. © 2016 by the American Institute of Ultrasound in Medicine.

  4. Experimental Hypersonic Aerodynamic Characteristics of the 2001 Mars Surveyor Precision Lander with Flap

    NASA Technical Reports Server (NTRS)

    Horvath, Thomas J.; OConnell, Tod F.; Cheatwood, F. McNeil; Prabhu, Ramadas K.; Alter, Stephen J.

    2002-01-01

    Aerodynamic wind-tunnel screening tests were conducted on a 0.029 scale model of a proposed Mars Surveyor 2001 Precision Lander (70 deg half angle spherically blunted cone with a conical afterbody). The primary experimental objective was to determine the effectiveness of a single flap to trim the vehicle at incidence during a lifting hypersonic planetary entry. The laminar force and moment data, presented in the form of coefficients, and shock patterns from schlieren photography were obtained in the NASA Langley Aerothermodynamic Laboratory for post-normal shock Reynolds numbers (based on forebody diameter) ranging from 2,637 to 92,350, angles of attack ranging from 0 tip to 23 degrees at 0 and 2 degree sideslip, and normal-shock density ratios of 5 and 12. Based upon the proposed entry trajectory of the 2001 Lander, the blunt body heavy gas tests in CF, simulate a Mach number of approximately 12 based upon a normal shock density ratio of 12 in flight at Mars. The results from this experimental study suggest that when traditional means of providing aerodynamic trim for this class of planetary entry vehicle are not possible (e.g. offset c.g.), a single flap can provide similar aerodynamic performance. An assessment of blunt body aerodynamic effects attributed to a real gas were obtained by synergistic testing in Mach 6 ideal-air at a comparable Reynolds number. From an aerodynamic perspective, an appropriately sized flap was found to provide sufficient trim capability at the desired L/D for precision landing. Inviscid hypersonic flow computations using an unstructured grid were made to provide a quick assessment of the Lander aerodynamics. Navier-Stokes computational predictions were found to be in very good agreement with experimental measurement.

  5. Three-dimensional transition after wake deflection behind a flapping foil.

    PubMed

    Deng, Jian; Caulfield, C P

    2015-04-01

    We report the inherently three-dimensional linear instabilities of a propulsive wake, produced by a flapping foil, mimicking the caudal fin of a fish or the wing of a flying animal. For the base flow, three sequential wake patterns appear as we increase the flapping amplitude: Bénard-von Kármán (BvK) vortex streets; reverse BvK vortex streets; and deflected wakes. Imposing a three-dimensional spanwise periodic perturbation, we find that the resulting Floquet multiplier |μ| indicates an unstable "short wavelength" mode at wave number β=30, or wavelength λ=0.21 (nondimensionalized by the chord length) at sufficiently high flow Reynolds number Re=Uc/ν≃600, where U is the upstream flow velocity, c is the chord length, and ν is the kinematic viscosity of the fluid. Another, "long wavelength" mode at β=6 (λ=1.05) becomes critical at somewhat higher Reynolds number, although we do not expect that this mode would be observed physically because its growth rate is always less than the short wavelength mode, at least for the parameters we have considered. The long wavelength mode has certain similarities with the so-called mode A in the drag wake of a fixed bluff body, while the short wavelength mode appears to have a period of the order of twice that of the base flow, in that its structure seems to repeat approximately only every second cycle of the base flow. Whether it is appropriate to classify this mode as a truly subharmonic mode or as a quasiperiodic mode is still an open question however, worthy of a detailed parametric study with various flapping amplitudes and frequencies.

  6. Three-dimensional transition after wake deflection behind a flapping foil

    NASA Astrophysics Data System (ADS)

    Deng, Jian; Caulfield, C. P.

    2015-04-01

    We report the inherently three-dimensional linear instabilities of a propulsive wake, produced by a flapping foil, mimicking the caudal fin of a fish or the wing of a flying animal. For the base flow, three sequential wake patterns appear as we increase the flapping amplitude: Bénard-von Kármán (BvK) vortex streets; reverse BvK vortex streets; and deflected wakes. Imposing a three-dimensional spanwise periodic perturbation, we find that the resulting Floquet multiplier |μ | indicates an unstable "short wavelength" mode at wave number β =30 , or wavelength λ =0.21 (nondimensionalized by the chord length) at sufficiently high flow Reynolds number Re=U c /ν ≃600 , where U is the upstream flow velocity, c is the chord length, and ν is the kinematic viscosity of the fluid. Another, "long wavelength" mode at β =6 (λ =1.05 ) becomes critical at somewhat higher Reynolds number, although we do not expect that this mode would be observed physically because its growth rate is always less than the short wavelength mode, at least for the parameters we have considered. The long wavelength mode has certain similarities with the so-called mode A in the drag wake of a fixed bluff body, while the short wavelength mode appears to have a period of the order of twice that of the base flow, in that its structure seems to repeat approximately only every second cycle of the base flow. Whether it is appropriate to classify this mode as a truly subharmonic mode or as a quasiperiodic mode is still an open question however, worthy of a detailed parametric study with various flapping amplitudes and frequencies.

  7. Evaluation of dynamic infrared thermography as an alternative to CT angiography for perforator mapping in breast reconstruction: a clinical study.

    PubMed

    Weum, Sven; Mercer, James B; de Weerd, Louis

    2016-07-15

    The current gold standard for preoperative perforator mapping in breast reconstruction with a DIEP flap is CT angiography (CTA). Dynamic infrared thermography (DIRT) is an imaging method that does not require ionizing radiation or contrast injection. We evaluated if DIRT could be an alternative to CTA in perforator mapping. Twenty-five patients scheduled for secondary breast reconstruction with a DIEP flap were included. Preoperatively, the lower abdomen was examined with hand-held Doppler, DIRT and CTA. Arterial Doppler sound locations were marked on the skin. DIRT examination involved rewarming of the abdominal skin after a mild cold challenge. The locations of hot spots on DIRT were compared with the arterial Doppler sound locations. The rate and pattern of rewarming of the hot spots were analyzed. Multiplanar CT reconstructions were used to see if hot spots were related to perforators on CTA. All flaps were based on the perforator selected with DIRT and the surgical outcome was analyzed. First appearing hot spots were always associated with arterial Doppler sounds and clearly visible perforators on CTA. The hot spots on DIRT images were always slightly laterally located in relation to the exit points of the associated perforators through the rectus abdominis fascia on CTA. Some periumbilical perforators were not associated with hot spots and showed communication with the superficial inferior epigastric vein on CTA. The selected perforators adequately perfused all flaps. This study confirms that perforators selected with DIRT have arterial Doppler sound, are clearly visible on CTA and provide adequate perfusion for DIEP breast reconstruction. Retrospectively registered at ClinicalTrials.gov with identifier NCT02806518 .

  8. On the Kelvin-Helmholtz and von Kármán vortices in the near-wake of semicircular cylinders with flaps

    NASA Astrophysics Data System (ADS)

    Liu, Boshen; Hamed, Ali M.; Chamorro, Leonardo P.

    2018-01-01

    The signatures of the Kelvin-Helmoltz (K-H) and von Kármán (VK) vortices shed from a semicircular cylinder with flaps of length L/d = 0, 1/3, 1, 2, and 3 were investigated using hotwire anemometry. Here, L and d denote the flap length and diameter of the semi-circular cylinder, respectively. Experiments were performed at Reynolds numbers spanning one order of magnitude, Re ∈ [8.4 × 103, 6.7 × 104]. The results highlight the impact of the flow modulation through rigid flaps on the wake characteristics and dominant vortex shedding. The increase of flap length resulted in reduced mean shear in the near-wake, which influenced the onset and coherence of the K-H instability. Indeed, these motions are less likely to be present in the wake of the L/d = 3 case. The flaps also impacted the frequency of the VK shedding; the associated Strouhal number increased from 0.2 to 0.3 for flaps L/d ≳ 1. Only the cases without with the shortest flaps (L/d = 1/3) followed St = 0.2. There is a distinctive dependence of the fK - H/fVK on Reynolds number and flap length. This ratio followed the well-known power-law relationship of circular cylinders in the case without flaps. However, the Reynolds number exponent decreased with increased flap length.

  9. Extending the use of the gracilis muscle flap in perineal reconstruction surgery.

    PubMed

    Goldie, Stephen J; Almasharqah, Riyadh; Fogg, Quentin A; Anderson, William

    2016-08-01

    Reconstruction of the perineum is required following oncological resections. Plastic surgical techniques can be used to restore the aesthetics and function of the perineum. The gracilis myocutaneous flap provides a substantial skin paddle, with minimal donor site morbidity. The flap is pedicled on a perforator from the medial circumflex femoral artery, giving it limited reach across the perineum. Tunnelling the flap under the adductor longus muscle may free up more of the arterial pedicle, increasing its reach. On three female cadavers, bilateral gracilis flaps were raised in the standard surgical manner, giving six flaps in total. With the flaps pedicled across the perineum, the distance from the tip of each flap was measured to the anterior superior iliac spine (ASIS). The flaps were then tunnelled under the adductor longus muscle. The distances to the ASIS were measured again. The average pedicle length was greater than 7 cm. Tunnelling the flap under the adductor longus muscle increased the reach by more than 4 cm on average. Cadaveric dissection has shown that tunnelling of the flap in a novel way increase its reach across the perineum. This additional flexibility improves its use clinically and is of benefit to plastic surgeons operating in perineal reconstruction. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. [Comparative study of three series of neuro-cutaneous flaps used for coverage of leg defects].

    PubMed

    Jecan, C R; Alecu, L; Costan, I S

    2011-01-01

    The purpose of the trial was to compare three groups of neurocutaneous flaps used to cover defects in the calf, in terms of preoperative characteristics and postoperative results. The main objective was to evaluate the effectiveness of surgical method by testing the hypothesis: neurocutaneous flaps can be applied with clinical results comparable to other surgical methods. The results were presented in the text, through graphic figures and tables. Statistical comparisons were performed according to the results obtained from three series of neurocutaneous flaps in terms of demographic characteristics and those describing postoperative results. The results obtained in the three types of flaps were compared with studies published by other authors, confirming the working hypothesis. The most important results are: the neurocutaneous sural flap is a distal pedicled flap with increased vascular resistance; age and co-morbidities may influence the degree of immediate complications but not the final success rate; the covered defect surface (p = 0.035) is higher for the sural and saphenous flap; the number of days of hospitalization is significantly lower than for microsurgical transfer flaps (p = 0.022). The frequency of complications and reintervention rates were similar (p = 0.022). The study concludes that the sural neurocutaneous flap can be used to cover defects of up to 200 cm2 in the calf with similar results to those of microsurgical transfer flaps.

  11. Challenges in the reconstruction of bilateral maxillectomy defects.

    PubMed

    Joseph, Shawn T; Thankappan, Krishnakumar; Buggaveeti, Rahul; Sharma, Mohit; Mathew, Jimmy; Iyer, Subramania

    2015-02-01

    Bilateral maxillectomy defects, if not adequately reconstructed, can result in grave esthetic and functional problems. The purpose of this study was to investigate the outcome of reconstruction of such defects. This is a retrospective case series. The defects were analyzed for their components and the flaps used for reconstruction. Outcomes for flap loss and functional indices, including oral diet, speech, and dental rehabilitation, also were evaluated. Ten consecutive patients who underwent bilateral maxillectomy reconstruction received 14 flaps. Six patients had malignancies of the maxilla, and 4 patients had nonmalignant indications. Ten bony free flaps were used. Four soft tissue flaps were used. The fibula free flap was the most common flap used. Three patients had total flap loss. Seven patients were alive and available for functional evaluation. Of these, 4 were taking an oral diet with altered consistency and 2 were on a regular diet. Speech was intelligible in all patients. Only 2 patients opted for dental rehabilitation with removable dentures. Reconstruction after bilateral maxillectomy is essential to prevent esthetic and functional problems. Bony reconstruction is ideal. The fibula bone free flap is commonly used. The complexity of the defect makes reconstruction difficult and the initial success rate of free flaps is low. Secondary reconstructions after the initial flap failures were successful. A satisfactory functional outcome can be achieved. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Gastrocnaemius-propeller extended miocutanous flap: a new chimaeric flap for soft tissue reconstruction of the knee.

    PubMed

    Innocenti, M; Cardin-Langlois, E; Menichini, G; Baldrighi, C

    2014-02-01

    Soft tissue defects involving the anterior aspect of the knee are a frequent finding in a number of pathological conditions. The aim of this article is to describe a new pedicled flap consisting of a conventional medial gastrocnaemius muscle flap associated with a propeller flap based on a perforator of the medial sural artery. Five males ranging in age between 26 and 72 years underwent a reconstruction of the soft tissue of the knee by means of the described procedure. Three patients sustained complex tissue loss subsequent to high-energy trauma; two losses were due to septic complications after elective knee surgery. Four flaps survived allowing adequate proximal tibial metaphysis and patella coverage. One patient underwent early above-the-knee amputation due to life-threatening septicaemia. The described chimaera flap consists of a medial gastrocnaemius flap with a skin paddle that is elevated on a perforator of the medial sural artery and then rotated according to the propeller flaps' principles. It provides effective coverage of large soft tissue defects of the knee. In the authors' experience, the propeller flap portion proved to be particularly useful to cover the patella, while the muscle flap was used to cover the proximal metaphysis of the tibia and fill the dead space if present. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Free-style Deepithelialized Propeller Flaps: An Ideal Local Flap to Obliterate Wounds with Dead Space.

    PubMed

    Datli, Asli; Suh, HyunSuk; Kim, Young Chul; Choi, Doon Hoon; Hong, Joon Pio Jp

    2017-03-01

    The reconstruction of the posterior trunk, especially with large dead spaces, remains challenging. Regional muscle flaps may lack adequate volume and reach. The purpose of this report was to evaluate the efficacy of deepithelialized free-style perforator-based propeller flaps to obliterate defects with large dead space. A total of 7 patients with defects on the posterior trunk with large dead spaces were evaluated. After complete debridement or resection, all flaps were designed on a single perforator adjacent to the defect, deepithelialized, and then rotated in a propeller fashion. Flaps were further modified in some cases such as folding the flap after deepithelialization to increase bulk and to obliterate the dead space. The flap dimension ranged from 10 × 5 × 1 to 15 × 8 × 2.5 cm based on a single perforator. The rotation arch of the flap ranged from 90 to 180 degrees. Uneventful healing was noted in all cases. One case showed latent redness and swelling at 7 months after falling down, which resolved with medication. During the average follow-up of 28 months, there were no other flap and donor site complications. The deepithelialized propeller flap can be used efficiently to obliterate dead spaces in the posterior trunk and retains advantages such as having a good vascular supply, adequate bulk, sufficient reach without tension, and minimal donor site morbidity.

  14. Reconstruction of Extensive Soft-Tissue Defects with Concomitant Bone Defects in the Lower Extremity with the Latissimus Dorsi-Serratus Anterior-Rib Free Flap.

    PubMed

    Sia, Wei Tee; Xu, Germaine Guiqin; Puhaindran, Mark Edward; Tan, Bien Keem; Cheng, Mathew Hern Wang; Chew, Winston Yoon Chong

    2015-07-01

    The combined latissimus dorsi-serratus anterior-rib (LD-SA-rib) free flap provides a large soft-tissue flap with a vascularized bone flap through a solitary vascular pedicle in a one-stage reconstruction. Seven LD-SA-rib free flaps were performed in seven patients to reconstruct concomitant bone and extensive soft-tissue defects in the lower extremity (tibia, five; femur, one; foot, one). The patients were all male, with an average age of 34 years (range, 20-48 years). These defects were secondary to trauma in five patients and posttraumatic osteomyelitis in two patients. All flaps survived and achieved bony union. The average time to bony union was 9.4 months. Bone hypertrophy of at least 20% occurred in all flaps. All patients achieved full weight-bearing ambulation without aid at an average duration of 23.7 months. Two patients developed stress fractures of the rib flap. There was no significant donor site morbidity, except for two patients who had pleural tears during harvesting of the flap. The LD-SA-rib flap provides a large soft-tissue component and a vascularized bone flap for reconstruction of composite large soft-tissue defects with concomitant bone defects of the lower extremity in a one-stage procedure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Gurney flap—Lift enhancement, mechanisms and applications

    NASA Astrophysics Data System (ADS)

    Wang, J. J.; Li, Y. C.; Choi, K.-S.

    2008-01-01

    Since its invention by a race car driver Dan Gurney in 1960s, the Gurney flap has been used to enhance the aerodynamics performance of subsonic and supercritical airfoils, high-lift devices and delta wings. In order to take stock of recent research and development of Gurney flap, we have carried out a review of the characteristics and mechanisms of lift enhancement by the Gurney flap and its applications. Optimum design of the Gurney flap is also summarized in this paper. For the Gurney flap to be effective, it should be mounted at the trailing edge perpendicular to the chord line of airfoil or wing. The flap height must be of the order of local boundary layer thickness. For subsonic airfoils, an additional Gurney flap increases the pressure on the upstream surface of the Gurney flap, which increases the total pressure of the lower surface. At the same time, a long wake downstream of the flap containing a pair of counter-rotating vortices can delay or eliminate the flow separation near the trailing edge on the upper surface. Correspondingly, the total suction on the airfoil is increased. For supercritical airfoils, the lift enhancement of the Gurney flap mainly comes from its ability to shift the shock on the upper surface in the downstream. Applications of the Gurney flap to modern aircraft design are also discussed in this review.

  16. Multiple-digit resurfacing using a thin latissimus dorsi perforator flap.

    PubMed

    Kim, Sang Wha; Lee, Ho Jun; Kim, Jeong Tae; Kim, Youn Hwan

    2014-01-01

    Traumatic digit defects of high complexity and with inadequate local tissue represent challenging surgical problems. Recently, perforator flaps have been proposed for reconstructing large defects of the hand because of their thinness and pliability and minimal donor site morbidity. Here, we illustrate the use of thin latissimus dorsi perforator flaps for resurfacing multiple defects of distal digits. We describe the cases of seven patients with large defects, including digits, circumferential defects and multiple-digit defects, who underwent reconstruction with thin latissimus dorsi perforator flaps between January 2008 and March 2012. Single-digit resurfacing procedures were excluded. The mean age was 56.3 years and the mean flap size was 160.4 cm(2). All the flaps survived completely. Two patients had minor complications including partial flap loss and scar contracture. The mean follow-up period was 11.7 months. The ideal flap for digit resurfacing should be thin and amenable to moulding, have a long pedicle for microanastomosis and have minimal donor site morbidity. Thin flaps can be harvested by excluding the deep adipose layer, and their high pliability enables resurfacing without multiple debulking procedures. The latissimus dorsi perforator flap may be the best flap for reconstructing complex defects of the digits, such as large, multiple-digit or circumferential defects, which require complete wrapping of volar and dorsal surfaces. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Latissimus Dorsi Myocutaneous Flap for Breast Reconstruction: Bad Rap or Good Flap?

    PubMed Central

    Perdikis, Galen; Koonce, Stephanie; Collis, George; Eck, Dustin

    2011-01-01

    Objective: This article serves to review latissimus dorsi myocutaneous flap as an option for breast reconstruction postmastectomy. Since the introduction of the latissimus dorsi myocutaneous flap in the late 1970s, its use has always been as a secondary technique, particularly after the development of the transverse rectus abdominus myocutaneous flap in the 1980s. Methods: A literature review of the history of latissimus dorsi myocutaneous flap utilized for breast reconstruction as well as a review of our institution's experience with latissimus dorsi myocutaneous flap and tissue expander placement was performed. Results: There remains a paucity of published studies investigating latissimus dorsi myocutaneous flap for breast reconstruction. Most studies have small numbers and do not utilize tissue expanders. More recently several small studies have been published that show acceptably low complication rates with aesthetically pleasing outcomes when latissimus dorsi myocutaneous flap is employed with a tissue expander. At our institution, we have employed latissimus dorsi myocutaneous flap with tissue expander placement for both delayed and immediate reconstruction with subsequent replacement with a permanent implant with a capsular contraction rate of 10.5%. Our data and others more recently published demonstrate very acceptable capsular contracture rates and aesthetic outcomes, particularly when an expander is utilized. Conclusion: The latissimus dorsi myocutaneous flap remains an excellent choice for breast reconstruction with a low risk of complications. PMID:22031843

  18. "All-laser" endothelial corneal transplant in human patients

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Menabuoni, Luca; Malandrini, Alex; Canovetti, Annalisa; Lenzetti, Ivo; Pini, Roberto

    2012-03-01

    Femtosecond laser sculpturing of corneal tissue is commonly used for the preparation of endothelial flaps. Diode laser welding of ocular tissues is a procedure that enables minimally invasive suturing of tissues. The combination of these laser based techniques results in a new approach to minimally invasive ophthalmic surgery, such as in endothelial corneal transplant (or endothelial keratoplasty - EK). In this work we present the "all laser" EK performed in human subjects. 24 pseudophakic patients with bullous keratopathy underwent EK: the femtosecond laser was used to prepare the 100 ìm thick and 8.5 mm diameter donor Descemet endothelial flap. After staining the stromal layer of the donor flap with a liquid ICG solution, the donor flap was inserted in the recipient eye by the use of the Busin injector. Then, the endothelial layer was laser-welded to the recipient eye (10 laser spots around the periphery of the flap), in order to reduce the risk of postoperative dislocation of the transplanted flap. A transplanted flap engraftment was observed in all the treated eyes. The staining procedure used to perform laser welding also enabled to evidence the stromal side of the donor flap, so as the flap was always placed in the right side position. The endothelial cells counts in both the laserwelded flaps and in a control group were in good agreement. The proposed technique is easy to perform and enables the reduction of postoperative endothelial flap dislocations.

  19. Distally based posterior interosseous flap: primary role in soft-tissue reconstruction of the hand.

    PubMed

    Agir, Hakan; Sen, Cenk; Alagöz, Sahin; Onyedi, Murat; Isil, Eda

    2007-09-01

    A series of 15 consecutive patients with various hand defects requiring flap coverage was reviewed in this study. The defects were all covered with the distally based posterior interosseous flap. Its main indications were in complex hand trauma, severe burn injury, or skin cancer ablation, either acute or postprimary. In 12 of the patients, flaps survived completely. In 3 patients, there was partial necrosis of the distal part of the flap, which did not require additional surgical procedure. Radial nerve palsy was noted in one of the cases, with a complete recovery after 3 months. Donor site was closed directly in up to 4-cm-wide flaps, while larger flaps required skin grafting. No major anatomic variation was observed. Distally based posterior interosseous flap is a reliable choice for various types and areas of hand defects, with very low donor-site morbidity, and should be more commonly considered in clinical practice.

  20. Cost-effectiveness of monitoring free flaps.

    PubMed

    Subramaniam, Shiva; Sharp, David; Jardim, Christopher; Batstone, Martin D

    2016-06-01

    Methods of free flap monitoring have become more sophisticated and expensive. This study aims to determine the cost of free flap monitoring and examine its cost effectiveness. We examined a group of patients who had had free flaps to the head and neck over a two-year period, and combined these results with costs obtained from business managers and staff. There were 132 free flaps with a success rate of 99%. The cost of monitoring was Aus $193/flap. Clinical monitoring during this time period cost Aus$25 476 and did not lead to the salvage of any free flaps. Cost equivalence is reached between monitoring and not monitoring only at a failure rate of 15.8%. This is to our knowledge the first study to calculate the cost of clinical monitoring of free flaps, and to examine its cost-effectiveness. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  1. Reconstruction of Facial Defect Using Deltopectoral Flap.

    PubMed

    Aldelaimi, Tahrir N; Khalil, Afrah A

    2015-11-01

    Reconstruction of the head and neck is a challenge for otolarygology surgeons, maxillofacial surgeons as well as plastic surgeons. Defects caused by the resection and/or trauma should be closed with flaps which match in color, texture and hair bearing characteristics with the face. Deltopectoral flap is a one such flap from chest and neck skin mainly used to cover the facial defects. This study report a patient presenting with tragic Road Traffic Accident (RTA) admitted to maxillofacial surgery department at Ramadi Teaching Hospital, Anbar province, Iraq. An incision, medially based, was done and deltopectoral fascio-cutaneous flap was used for surgical exposure and closure of defects after RTA. There was no major complication. Good aesthetic and functional results were achieved. Deltopectoral flap is an excellent alternative for the reconstruction of head and neck. Harvesting and application of the flap is rapid and safe. Only a single incision is sufficient for dissection and flap elevation.

  2. Perforator-based propeller flaps reliability in upper extremity soft tissue reconstruction: a systematic review.

    PubMed

    Vitse, J; Bekara, F; Bertheuil, N; Sinna, R; Chaput, B; Herlin, C

    2017-02-01

    Current data on upper extremity propeller flaps are poor and do not allow the assessment of the safety of this technique. A systematic literature review was conducted searching PubMed, EMBASE, and the Cochrane Library electronic databases, and the selection process was adapted from the preferred reporting items for systematic reviews and meta-analysis statement. The final analysis included ten relevant articles involving 117 flaps. The majority of flaps were used for the hand, distal wrist, and elbow. The radial artery perforator and ulnar artery perforator were the most frequently used flaps. The were 7% flaps with venous congestion and 3% with complete necrosis. No difference in complications rate was found for different flaps sites. Perforator-based propeller flaps appear to be an interesting procedure for covering soft tissue defects involving the upper extremities, even for large defects, but the procedure requires experience and close monitoring. II.

  3. The midline-based nasolabial transposition (MNT) flap: an original single-stage technique for nasal tip reconstruction.

    PubMed

    Beustes-Stefanelli, Matthieu; O'Toole, Greg; Schertenleib, Pierre

    2015-04-01

    Nasolabial flaps based on the lateral side of the nose for the reconstruction of lateral nasal defects in a single-stage procedure have been described. Similarly, in midline defects, nasolabial flaps can be used but a 2-stage procedure is classically required. The Midline-based Nasolabial Transposition (MNT) flap is presented as a new single-stage procedure for nasal tip reconstruction. Between 2009 and 2011, an MNT flap was used as a single-stage procedure in 3 cases of large nasal defects of the tip where the forehead flap was either contraindicated or rejected as an option by the patient. There were no complications and a satisfactory aesthetic result was achieved in all cases. The MNT flap is a new single-stage procedure for large nasal tip defects and as such represents an interesting alternative to the classical 2-stage forehead and nasolabial flaps, especially in elderly patients.

  4. Innervated boomerang flap for finger pulp reconstruction.

    PubMed

    Chen, Shao-Liang; Chiou, Tai-Fung

    2007-11-01

    The boomerang flap originates from the dorsolateral aspect of the proximal phalanx of an adjacent digit and is supplied by the retrograde blood flow through the vascular arcades between the dorsal and palmar digital arteries. To provide sensation of the boomerang flap for finger pulp reconstruction, the dorsal sensory branch of the proper digital nerve and the superficial sensory branch of the corresponding radial or ulnar nerve are included within the skin flap. After transfer of the flap to the injured site, epineural neurorrhaphies are done between the digital nerves of the pulp and the sensory branches of the flap. We used this sensory flap in five patients, with more than 1 year follow-up, and all patients achieved measurable two-points discrimination. The boomerang flap not only preserves the proper palmar digital artery but also provides an extended and innervated skin paddle. It seems to be an alternative choice for one-stage reconstruction of major pulp defect.

  5. Comparison of gluteal fasciocutaneous rotational flaps and myocutaneous flaps for the treatment of sacral sores

    PubMed Central

    Ip, F. K.

    2005-01-01

    To compare the outcomes of gluteal fasciocutaneous rotational flaps and myocutaneous flaps in the treatment of sacral sores, together with a review of surgical complications in two matched cohorts. Thirty-eight patients (18 gluteal fasciocutaneous rotational flaps and 20 myocutaneous flaps) were reviewed retrospectively at a mean follow-up of 58 weeks. The rate of healing of the sore, the sore healing time, and the incidence of surgical complications, together with rate of recurrence, were obtained by chart review. Treatment groups were matched by patient characteristics, operative time and blood loss. The rate of healing of the sore, sore healing time and complication rate were comparable in the two groups but the rate of recurrence was lower to a statistically significant extent in myocutaneous flap patients. The authors suggest that both methods are comparable, good and safe in treating sacral sores; myocutaneous flaps are more durable. PMID:16333656

  6. Planarian yorkie/YAP functions to integrate adult stem cell proliferation, organ homeostasis and maintenance of axial patterning.

    PubMed

    Lin, Alexander Y T; Pearson, Bret J

    2014-03-01

    During adult homeostasis and regeneration, the freshwater planarian must accomplish a constant balance between cell proliferation and cell death, while also maintaining proper tissue and organ size and patterning. How these ordered processes are precisely modulated remains relatively unknown. Here we show that planarians use the downstream effector of the Hippo signaling cascade, yorkie (yki; YAP in vertebrates) to control a diverse set of pleiotropic processes in organ homeostasis, stem cell regulation, regeneration and axial patterning. We show that yki functions to maintain the homeostasis of the planarian excretory (protonephridial) system and to limit stem cell proliferation, but does not affect the differentiation process or cell death. Finally, we show that Yki acts synergistically with WNT/β-catenin signaling to repress head determination by limiting the expression domains of posterior WNT genes and that of the WNT-inhibitor notum. Together, our data show that yki is a key gene in planarians that integrates stem cell proliferation control, organ homeostasis, and the spatial patterning of tissues.

  7. The temporalis muscle flap and temporoparietal fascial flap.

    PubMed

    Lam, Din; Carlson, Eric R

    2014-08-01

    The temporal arterial system provides reliable vascular anatomy for the temporalis muscle flap and temporoparietal fascial flap that can support multiple reconstructive needs of the oral and maxillofacial region. The minimal donor site morbidity and ease of development of these flaps result in their predictable and successful transfer for reconstructive surgery of the oral and maxillofacial region. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. 50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 10 2014-10-01 2014-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES... MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 16 Figure 16 to Part 223—Escape Opening and Flap Dimensions...

  9. 50 CFR Figure 16 to Part 223 - Escape Opening and Flap Dimensions for the Double Cover Flap TED

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 10 2013-10-01 2013-10-01 false Escape Opening and Flap Dimensions for the Double Cover Flap TED 16 Figure 16 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES... MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 16 Figure 16 to Part 223—Escape Opening and Flap Dimensions...

  10. Outcomes of using a modified anteromedial thigh perforator flap for repairing the anterolateral thigh free flap donor site: A retrospective clinical review.

    PubMed

    Zhou, Xiao; Wang, Jin; Qiang, Li; Rui, Yongjun; Xue, Mingyu

    2018-04-01

    The anterolateral thigh (ALT) flap plays an essential part in plastic and reconstructive surgery. However, repair of the anterolateral donor site has not been the focus of the clinicians.To assess the clinical value and feasibility of using a modified anteromedial thigh (AMT) perforator flap for repairing the ALT free flap donor site.In this retrospective study, 16 ALT flaps were transferred to resurface large soft-tissue defects (ranged from 7 × 5 to 13 × 8 cm) in the foot or hand from June 2012 to March 2013. The donor sites were repaired with an advancement flap pedicled with an AMT perforator. Sensation within the advancement flap, return-to-work (RTW) time, the aesthetic appearance of the donor sites, and functional recovery were measured.All 15 flaps survived completely without necrosis. One flap developed partial necrosis in the tip but healed with dressing changes after 1 week. The medain follow-up period was 3.5 months (range, 3-6 months). The average median time was 9.5 weeks (range 8-13 weeks). There was no numbness of the advancement flap. Additionally, there was no specific complication at both the recipient and donor sites. Thigh quadriceps muscle strength and activities of the knee were normal. All patients were satisfied with the aesthetic outcome postoperatively at the 3-month to 6-month follow-up.The modified advancement flap pedicled with an AMT perforator is an ideal option for repairing the anterolateral donor site.

  11. Platelet-rich plasma reduces skin flap inflammatory cells infiltration and improves survival rates through induction of angiogenesis: An experiment in rabbits.

    PubMed

    Wang, Biao; Geng, Qiuhua; Hu, Junling; Shao, Jianchuan; Ruan, Jing; Zheng, Jiansheng

    2016-08-01

    This study was conducted to evaluate the effects of platelet-rich plasma (PRP) on flap survival in an experimental rabbit model. Symmetrical rectangular dorsal cutaneous flaps (8 × 2 cm) were elevated in 15 rabbits. The rabbits were randomly divided into a 3-day group (n = 5), a 7-day group (n = 5), and a 14-day group (n = 5). Either side of the dorsum was selected for injection of PRP into the flap basal surface, while the other side received an equal volume of saline as a control. The flaps were immediately sutured back, after which the flap survival was measured and histology specimens were collected at 3, 7, and 14 days. Platelet-rich plasma significantly improved flap survival rates of the PRP side flaps relative to the control in the 3-day (74.4% ± 4.7% vs 65.8% ± 6.8%; p < 0.05), 7-day (72.4% ± 7.5% vs 58.5% ± 7.0%; p < 0.05), and 14-day (74.5% ± 5.0% vs 65.0% ± 5.4%; p < 0.05) groups. Histological analysis revealed significantly fewer inflammatory cells and an increased blood vessel density in the platelet-rich plasma side flap vs the blank control side flap. Platelet-rich plasma (PRP) promotes the survival of random rabbit flaps and, therefore, represents a promising treatment to prevent skin flap necrosis in reconstructive and plastic surgery.

  12. Comparison of hatchet-shaped tensor fascia lata flap and pedicle anterior lateral thigh flap for treatment of trochanteric sores: a retrospective analysis of 48 patients.

    PubMed

    Li, Chun-Chang; Chang, Shun-Cheng; Fu, Ju-Peng; Tzeng, Yuan-Sheng; Wang, Chih-Hsing; Chen, Tim-Mo; Chen, Shyi-Gen

    2013-12-01

    Surgical reconstruction of trochanteric sores remains a formidable task for plastic surgeons. Diverse types of flaps have been proposed for use in this situation, each with particular advantages and limitations. This study aimed to compare the surgical outcomes between the hatchet-shaped tensor fascia lata (TFL) flap and the pedicle anterior lateral thigh (ALT) flap in treatment of trochanteric sores. Forty-eight patients with trochanteric sores were operated on under spinal or general anesthesia using TFL or ALT flaps between August 2007 and November 2010. In the TFL group, 26 hatchet-shaped TFL musculocutaneous flaps were performed on 24 patients. In the ALT group, 25 pedicle ALT musculocutaneous flaps were performed on 24 patients. Surgical outcomes were retrospectively analyzed. No significant difference was detected between the TFL and ALT groups in terms of age, preoperative disease period, obesity (body mass index), American Society of Anesthesiologists score, comorbidity, the defect size, follow-up time, and complication rate. The recurrence rate and the flap size were significantly higher in the TFL group than in the ALT group (P = 0.022; P < 0.001). The operation time was longer in the ALT group (P < 0.001). The pedicle ALT flap is a more effective treatment than the TFL flap for the surgical management of trochanteric sores. The hatchet-shaped TFL flap should be reserved for the reconstruction of recurrent trochanteric sores or for use in the critically ill patient who cannot tolerate longer anesthesia and operation time.

  13. Combined application of latissimus dorsi myocutaneous flap and iliac bone flap in the treatment of chronic osteomyelitis of the lower extremity.

    PubMed

    Ju, Jihui; Li, Lei; Zhou, Rong; Hou, Ruixing

    2018-05-18

    To evaluate the clinical efficacy and safety of latissimus dorsi myocutaneous flap (stage I) combined with iliac bone flap (stage II) in the treatment of chronic osteomyelitis of the lower extremity. Clinical data of 18 patients undergoing latissimus dorsi myocutaneous flap in combination with iliac bone flap grafting were retrospectively analyzed. Among them, 2 patients developed chronic osteomyelitis of the lower segment of the femur, 4 were diagnosed with chronic osteomyelitis of the tibial plateau, and 12 with chronic osteomyelitis of the lower segment of the tibia. All the latissimus dorsi myocutaneous flaps survived in 18 patients. After the corresponding surgery, primary wound healing was achieved in 11 patients, and delayed wound healing was obtained in 7 cases. All wounds were completely healed with postoperative 2 months. Following the iliac bone flap grafting, primary would healing was accomplished in all cases. All dorsal window chambers survived. The bone defects were properly restored within 4-12 postoperative months. Functional training was performed after removal of the internal and external fixators. Postoperative follow-up was endured from 6 months to 10 years. All patients were satisfied with the bone healing and flap texture without the incidence of osteomyelitis and sinus tract. No contraction was observed in the grafting area of 2 patients receiving latissimus dorsi myocutaneous flap grafting. Residual linear scars were noted in the dorsal and iliac donor sites. Combined usage of stage I latissimus dorsi myocutaneous flap and stage II iliac bone flap grafting is an efficacious and safe surgical technique in clinical practice.

  14. Non-Euclidean stress-free configuration of arteries accounting for curl of axial strips sectioned from vessels.

    PubMed

    Takamizawa, Keiichi; Nakayama, Yasuhide

    2013-11-01

    It is well known that arteries are subject to residual stress. In earlier studies, the residual stress in the arterial ring relieved by a radial cut was considered in stress analysis. However, it has been found that axial strips sectioned from arteries also curled into arcs, showing that the axial residual stresses were relieved from the arterial walls. The combined relief of circumferential and axial residual stresses must be considered to accurately analyze stress and strain distributions under physiological loading conditions. In the present study, a mathematical model of a stress-free configuration of artery was proposed using Riemannian geometry. Stress analysis for arterial walls under unloaded and physiologically loaded conditions was performed using exponential strain energy functions for porcine and human common carotid arteries. In the porcine artery, the circumferential stress distribution under physiological loading became uniform compared with that without axial residual strain, whereas a gradient of axial stress distribution increased through the wall thickness. This behavior showed almost the same pattern that was observed in a recent study in which approximate analysis accounting for circumferential and axial residual strains was performed, whereas the circumferential and axial stresses increased from the inner surface to the outer surface under a physiological condition in the human common carotid artery of a two-layer model based on data of other recent studies. In both analyses, Riemannian geometry was appropriate to define the stress-free configurations of the arterial walls with both circumferential and axial residual strains.

  15. Superficial ulnar artery perforator flap.

    PubMed

    Schonauer, Fabrizio; Marlino, Sergio; Turrà, Francesco; Graziano, Pasquale; Dell'Aversana Orabona, Giovanni

    2014-09-01

    Superficial ulnar artery is a rare finding but shows significant surgical implications. Its thinness and pliability make this flap an excellent solution for soft tissue reconstruction, especially in the head and neck region. We hereby report a successful free superficial ulnar artery perforator forearm flap transfer for tongue reconstruction. A 64-year-old man presenting with a squamous cell carcinoma of the left tongue underwent a wide resection of the tumor, left radical neck dissection, and reconstruction of the tongue and the left tonsillar pillar with the mentioned flap. No complications were observed postoperatively. The flap survived completely; no recurrence at 6 months of follow-up was detected. Superficial ulnar artery perforator flap has shown to be a safe alternative to other free tissue flaps in specific forearm anatomic conditions.

  16. Novel diffuse optics system for continuous tissue viability monitoring: extended recovery in vivo testing in a porcine flap model

    NASA Astrophysics Data System (ADS)

    Lee, Seung Yup; Pakela, Julia M.; Hedrick, Taylor L.; Vishwanath, Karthik; Helton, Michael C.; Chung, Yooree; Kolodziejski, Noah J.; Stapels, Christopher J.; McAdams, Daniel R.; Fernandez, Daniel E.; Christian, James F.; O'Reilly, Jameson; Farkas, Dana; Ward, Brent B.; Feinberg, Stephen E.; Mycek, Mary-Ann

    2017-02-01

    In reconstructive surgery, tissue perfusion/vessel patency is critical to the success of microvascular free tissue flaps. Early detection of flap failure secondary to compromise of vascular perfusion would significantly increase the chances of flap salvage. We have developed a compact, clinically-compatible monitoring system to enable automated, minimally-invasive, continuous, and quantitative assessment of flap viability/perfusion. We tested the system's continuous monitoring capability during extended non-recovery surgery using an in vivo porcine free flap model. Initial results indicated that the system could assess flap viability/perfusion in a quantitative and continuous manner. With proven performance, the compact form constructed with cost-effective components would make this system suitable for clinical translation.

  17. Pressure Distributions for the GA(W)-2 Airfoil with 20% Aileron, 25% Slotted Flap and 30% Fowler Flap

    NASA Technical Reports Server (NTRS)

    Wentz, W. H., Jr.; Fiscko, K. A.

    1978-01-01

    Surface pressure distributions were measured for the 13% thick GA(W)-2 airfoil section fitted with 20% aileron, 25% slotted flap and 30% Fowler flap. All tests were conducted at a Reynolds number of 2.2 x 10 to the 6th power and a Mach number of 0.13. Pressure distribution and force and moment coefficient measurements are compared with theoretical results for a number of cases. Agreement between theory and experiment is generally good for low angles of attack and small flap deflections. For high angles and large flap deflections where regions of separation are present, the theory is inadequate. Theoretical drag predictions are poor for all flap-extended cases.

  18. Primary control of a Mach scale swashplateless rotor using brushless DC motor actuated trailing edge flaps

    NASA Astrophysics Data System (ADS)

    Saxena, Anand

    The focus of this research was to demonstrate a four blade rotor trim in forward flight using integrated trailing edge flaps instead of using a swashplate controls. A compact brushless DC motor was evaluated as an on-blade actuator, with the possibility of achieving large trailing edge flap amplitudes. A control strategy to actuate the trailing edge flap at desired frequency and amplitude was developed and large trailing edge flap amplitudes from the motor (instead of rotational motion) were obtained. Once the actuator was tested on the bench-top, a lightweight mechanism was designed to incorporate the motor in the blade and actuate the trailing edge flaps. A six feet diameter, four bladed composite rotor with motor-flap system integrated into the NACA 0012 airfoil section was fabricated. Systematic testing was carried out for a range of load conditions, first in the vacuum chamber followed by hover tests. Large trailing edge flap deflections were observed during the hover testing, and a peak to peak trailing edge flap amplitude of 18 degree was achieved at 2000 rotor RPM with hover tip Mach number of 0.628. A closed loop controller was designed to demonstrate trailing edge flap mean position and the peak to peak amplitude control. Further, a soft pitch link was designed and fabricated, to replace the stiff pitch link and thereby reduce the torsional stiffness of the blade to 2/rev. This soft pitch link allowed for blade root pitch motion in response to the trailing edge flap inputs. Blade pitch response due to both steady as well as sinusoidal flap deflections were demonstrated. Finally, tests were performed in Glenn L. Martin wind tunnel using a model rotor rig to assess the performance of motor-flap system in forward flight. A swashplateless trim using brushless DC motor actuated trailing edge flaps was achieved for a rotor operating at 1200 RPM and an advance ratio of 0.28. Also, preliminary exploration was carried out to test the scalability of the motor driven trailing edge flap concept. In conclusion, the concept of using brushless DC motors as on-blade actuators, actuating trailing edge flaps has the potential to replace the current mechanically complex swashplate with a hydraulic-free swashplateless system and thereby reduce overall weight and hub drag.

  19. Small scale noise and wind tunnel tests of upper surface blowing nozzle flap concepts. Volume 1. Aerodynamic test results

    NASA Technical Reports Server (NTRS)

    Renselaer, D. J.; Nishida, R. S.; Wilkin, C. A.

    1975-01-01

    The results and analyses of aerodynamic and acoustic studies conducted on the small scale noise and wind tunnel tests of upper surface blowing nozzle flap concepts are presented. Various types of nozzle flap concepts were tested. These are an upper surface blowing concept with a multiple slot arrangement with seven slots (seven slotted nozzle), an upper surface blowing type with a large nozzle exit at approximately mid-chord location in conjunction with a powered trailing edge flap with multiple slots (split flow or partially slotted nozzle). In addition, aerodynamic tests were continued on a similar multi-slotted nozzle flap, but with 14 slots. All three types of nozzle flap concepts tested appear to be about equal in overall aerodynamic performance but with the split flow nozzle somewhat better than the other two nozzle flaps in the landing approach mode. All nozzle flaps can be deflected to a large angle to increase drag without significant loss in lift. The nozzle flap concepts appear to be viable aerodynamic drag modulation devices for landing.

  20. Facial mimetic, cosmetic, and functional standardized assessment of the facial artery musculomucosal (FAMM) flap.

    PubMed

    Jowett, Nathan; Hadlock, Tessa A; Sela, Eyal; Toth, Miklos; Knecht, Rainald; Lörincz, Balazs B

    2017-04-01

    To objectively assess donor site morbidity after harvesting the facial artery musculomucosal flap. Use of the FAMM-flap in oral cavity reconstruction remains sporadic. This case series describes our newly developed standardized assessment of this flap in a floor of mouth (FOM) reconstructive setting. Standardized postoperative assessment of the FAMM flap for donor site wound complications, functional, facial mimetic and oncologic outcomes. There were no wound complications. Oral competence remained intact, tongue mobility was good to excellent, average word articulation score was 98%, and mimetic function excellent in all patients. Three patients experienced ipsilateral upper lip anesthesia, and five patients were noted to have slight dysfunction of the orbicularis oris resulting in a loss of lip height at rest. The FAMM flap is a reliable option for reconstruction of ablative defects of the FOM, and should be considered a workhorse flap for oral cavity defects. Unlike the submental island flap, a complete level I dissection may be concurrently performed without compromising the vascular supply to the FAMM flap. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Full-Scale Wind-Tunnel Investigation of a Jet Flap in Conjunction with a Plain Flap with Blowing Boundary-Layer Control on a 35 deg Sweptback-Wing Airplane

    NASA Technical Reports Server (NTRS)

    Aoyagi, Kiyoshi; Hickey, David H.

    1959-01-01

    Previous investigations have shown that increased blowing at the hinge-line radius of a plain flap will give flap lift increases above that realized with boundary-layer control. Other experiments and theory have shown that blowing from a wing trailing edge, through the jet flap effect, produced lift increases. The present investigation was made to determine whether blowing simultaneously at the hinge-line radius and trailing edge would be more effective than blowing separately at either location. The tests were made at a Reynolds number of 4.5 x 10(exp 6) with a 35 deg sweptback-wing airplane. For this report, only the lift data are presented. Of the three flap blowing arrangements tested, blowing distributed between the trailing edge and the hinge-line radius of a plain flap was found to be superior to blowing at either location separately at the plain flap deflections of interest. Comparison of estimated and experimental jet flap effectiveness was fair.

  2. Single-stage interpolation flaps in facial reconstruction.

    PubMed

    Hollmig, S Tyler; Leach, Brian C; Cook, Joel

    2014-09-01

    Relatively deep and complex surgical defects, particularly when adjacent to or involving free margins, present significant reconstructive challenges. When the use of local flaps is precluded by native anatomic restrictions, interpolation flaps may be modified to address these difficult wounds in a single operative session. To provide a framework to approach difficult soft tissue defects arising near or involving free margins and to demonstrate appropriate design and execution of single-stage interpolation flaps for reconstruction of these wounds. Examination of our utilization of these flaps based on an anatomic region and surgical approach. A region-based demonstration of flap conceptualization, design, and execution is provided. Tunneled, transposed, and deepithelialized variations of single-stage interpolation flaps provide versatile options for reconstruction of a variety of defects encroaching on or involving free margins. The inherently robust vascularity of these flaps supports importation of necessary tissue bulk while allowing aggressive contouring to restore an intricate native topography. Critical flap design allows access to distant tissue reservoirs and placement of favorable incision lines while preserving the inherent advantages of a single operative procedure.

  3. Static and wind tunnel model tests for the development of externally blown flap noise reduction techniques

    NASA Technical Reports Server (NTRS)

    Pennock, A. P.; Swift, G.; Marbert, J. A.

    1975-01-01

    Externally blown flap models were tested for noise and performance at one-fifth scale in a static facility and at one-tenth scale in a large acoustically-treated wind tunnel. The static tests covered two flap designs, conical and ejector nozzles, third-flap noise-reduction treatments, internal blowing, and flap/nozzle geometry variations. The wind tunnel variables were triple-slotted or single-slotted flaps, sweep angle, and solid or perforated third flap. The static test program showed the following noise reductions at takeoff: 1.5 PNdB due to treating the third flap; 0.5 PNdB due to blowing from the third flap; 6 PNdB at flyover and 4.5 PNdB in the critical sideline plane (30 deg elevation) due to installation of the ejector nozzle. The wind tunnel program showed a reduction of 2 PNdB in the sideline plane due to a forward speed of 43.8 m/s (85 kn). The best combination of noise reduction concepts reduced the sideline noise of the reference aircraft at constant field length by 4 PNdB.

  4. Pressure Distribution Over a Symmetrical Airfoil Section with Trailing Edge Flap

    NASA Technical Reports Server (NTRS)

    Jacobs, Eastman N; Pinkerton, Robert M

    1931-01-01

    Measurements were made to determine the distribution of pressure over one section of an R. A. F. 30 (symmetrical) airfoil with trailing edge flaps. In order to study the effect of scale measurements were made with air densities of approximately 1 and 20 atmospheres. Isometric diagrams of pressure distribution are given to show the effect of change in incidence, flap displacement, and scale upon the distribution. Plots of normal force coefficient versus angle of attack for different flap displacements are given to show the effect of a displaced flap. Plots are given of both the experimental and theoretical characteristic coefficients versus flap angle, in order to provide a comparison with the theory. It is concluded that for small flap displacements the agreement for the pitching and hinge moments is such that it warrants the use of the theoretical parameters. However, the agreement for the lift is not as good, particularly for the smaller flaps. In an appendix, an example is given of the calculation of the load and moments on an airfoil with hinged flap from these parameters.

  5. The free scapular/parascapular flap as a reliable method of reconstruction in the head and neck region: a retrospective analysis of 130 reconstructions performed over a period of 5 years in a single department.

    PubMed

    Mitsimponas, Konstantinos T; Iliopoulos, Christos; Stockmann, Philipp; Bumiller, Lars; Nkenke, Emeka; Neukam, Friedrich W; Schlegel, Karl-Andreas

    2014-07-01

    The scapular/parascapular free flap was described by Saijo in 1978 and has since then been widely used in reconstructive procedures. This is a retrospective study, describing our experience with the use of free scapula/parascapular flap in 130 reconstructions over a period of 5 years in the Department of Oral and Maxillofacial Surgery of the University Hospital of Erlangen. Demographical data, data regarding the underlying pathology, flap raising details, microvascular anastomoses, early and late postoperative complications will be presented. The flap was raised without problems and the donor site was primarily closed in all cases. Sixteen flaps required revision. Five transplants were lost (failure rate of 3.85%). Loss of part of the flap was observed in 3 cases (2.3%). The free scapula/parascapular flap is a versatile and reliable flap that can find many applications in the reconstruction of complex head and neck defects. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Reconstruction of trochanteric pressure sores with pedicled anterolateral thigh myocutaneous flaps.

    PubMed

    Wang, Chih-Hsin; Chen, Shih-Yi; Fu, Ju-Peng; Dai, Niann-Tzyy; Chen, Shao-Liang; Chen, Tim-Mo; Chen, Shyi-Gen

    2011-05-01

    To provide an alternative choice for covering trochanteric pressure sores, we report on a modified pedicle anterolateral thigh (ALT) myocutaneous flap based on the descending branch of the lateral circumflex femoral artery. From August 2007 to January 2010, 20 consecutive patients (10 men and 10 women) underwent 21 pedicled ALT myocutaneous flaps for reconstruction of trochanteric pressure sores. The flap was designed and elevated, resembling the ALT perforator flap including part of the vastus lateralis muscle but without skeletonisation of the perforators. The mean age of patients was 79.4 years (range: 46-103). The mean follow-up period was 13.9 months (range: 3-32). The flaps were 8-21 cm long and 5-11 cm wide. All flaps healed without major complications. All donor sites were closed primarily without skin grafting and showed good aesthetic results. No recurrence was observed. This modified design of pedicled ALT myocutaneous flap without skeletonisation of perforators is a reliable and easily harvested flap for reconstruction of trochanteric pressure sores with limited morbidity. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  7. Surgical Treatment of Iatrogenic Ventral Glottic Stenosis Using a Mucosal Flap Technique

    PubMed Central

    Barnett, Timothy P.; O'Leary, John Mark; Dixon, Padraic M.

    2016-01-01

    Objective To describe a novel surgical technique for correcting postoperative ventral glottic stenosis (cicatrix or web formation) and the outcome in 2 Thoroughbred racehorses. Study Design Retrospective case report. Animals Thoroughbreds diagnosed with ventral glottic stenosis (n=2). Methods Horses presenting with iatrogenic ventral glottic stenosis and resultant exercise intolerance and abnormal exercise‐related noise were anesthetized and a midline sagittal skin incision was made over the ventral larynx and between the sternohyoideus muscles overlying the cricothyroid notch. The cricothyroid ligament, attached laryngeal cicatrix, and overlying mucosa were sagittally sectioned at the dorsal aspect of the cicatrix on the left side. The laryngeal mucosa, cicatrix, and underlying cricothyroid ligament immediately rostral and caudal to the cicatrix were sectioned in a medial (axial) direction as far as the right side of the cricothyroid notch. After resection of the majority of the attached cicatrix tissue, the residual mucosal flap (attached to the right side of the larynx) was reflected ventrally and sutured to the attachment of the cricothyroid ligament on the right side of the cricothyroid notch, creating an intact mucosal layer on the right side of the ventral larynx. Results Both horses had good intralaryngeal wound healing with minimal redevelopment of ventral glottic stenosis at 5 and 9 months postoperatively and were successfully returned to racing with complete absence of abnormal respiratory noise. Conclusion The unique laryngeal anatomy of horses, with a cartilage‐free ventral laryngeal area (cricothyroid notch), allowed the use of this novel surgical technique to successfully treat ventral glottic stenosis. PMID:27013024

  8. Particle dynamics and pattern formation in a rotating suspension of positively buoyant particles

    NASA Astrophysics Data System (ADS)

    Konidena, Sudarshan; Lee, Jonghoon; Reddy, K. Anki; Singh, Anugrah

    2018-04-01

    Numerical simulations of positively buoyant suspension in a horizontally rotating cylinder were performed to study the formation of radial and axial patterns. The order parameter for the low-frequency segregated phase and dispersed phase is similar to that predicted for the settling suspension by Lee and Ladd [J. Fluid Mech. 577, 183 (2007), 10.1017/S002211200700465X], which is the average angular velocity of the particles. The particle density profiles for axial bands in the buoyancy-dominated phase shows an amplitude equivalent to the diameter of the cylinder. Axial density profiles show sinusoidal behavior for the drag-dominant phase and oscillating sinusoidal behavior for the centrifugal-force-dominant phase. Results also indicate that the traveling bands are formed as a consequence of the inhomogeneous distribution of particles arising from a certain imbalance of drag, buoyancy, and centrifugal forces. In the centrifugal limit, particles move towards the center of the cylinder, aggregating to form a dense core of particles with its axis coinciding with that of the rotating cylinder, a behavior which is in contrast to the sedimenting particles. The particle distribution patterns obtained from the simulations are found to be in good agreement with the experiments of Kalyankar et al. [Phys. Fluids 20, 083301 (2008), 10.1063/1.2970156].

  9. [DORSALIS PEDIS FLAP SERIES-PARALLEL BIG TOE NAIL COMPOSITE TISSUE FLAP TO REPAIR HAND SKIN OF DEGLOVING INJURY WITH THUMB DEFECT].

    PubMed

    Shi, Pengju; Zhang, Wenlong; Zhao, Gang; Li, Zhigang; Zhao, Shaoping; Zhang, Tieshan

    2015-07-01

    To investigate the effectiveness of dorsalis pedis flap series-parallel big toe nail composite tissue flap in the repairment of hand skin of degloving injury with tumb defect. Between March 2009 and June 2013, 8 cases of hand degloving injury with thumb defect caused by machine twisting were treated. There were 7 males and 1 female with the mean age of 36 years (range, 26-48 years). Injury located at the left hand in 3 cases and at the right hand in 5 cases. The time from injury to hospitalization was 1.5-4.0 hours (mean, 2.5 hours). The defect area was 8 cm x 6 cm to 15 cm x 1 cm. The thumb defect was rated as degree I in 5 cases and as degree II in 3 cases. The contralateral dorsal skin flap (9 cm x 7 cm to 10 cm x 8 cm) combined with ipsilateral big toe nail composite tissue flap (2.5 cm x 1.8 cm to 3.0 cm x 2.0 cm) was used, including 3 parallel anastomosis flaps and 5 series anastomosis flaps. The donor site of the dorsal flap was repaired with thick skin grafts, the stumps wound was covered with tongue flap at the shank side of big toe. Vascular crisis occurred in 1 big toe nail composite tissue flap, margin necrosis occurred in 2 dorsalis pedis flap; the other flaps survived, and primary healing of wound was obtained. The grafted skin at dorsal donor site all survived, skin of hallux toe stump had no necrosis. Eight cases were followed up 4-20 months (mean, 15.5 months). All flaps had soft texture and satisfactory appearance; the cutaneous sensory recovery time was 4-7 months (mean, 5 months). At 4 months after operation, the two-point discrimination of the thumb pulp was 8-10 mm (mean, 9 mm), and the two-point discrimination of dorsal skin flap was 7-9 mm (mean, 8.5 mm). According to Society of Hand Surgery standard for the evaluation of upper part of the function, the results were excellent in 4 cases, good in 3 cases, and fair in 1 case. The donor foot had normal function. Dorsalis pedis flap series-parallel big toe nail composite tissue flap is an ideal way to repair hand skin defect, and reconstructs the thumb, which has many advantages, including simple surgical procedure, no limitation to recipient site, soft texture, satisfactory appearance and function of reconstructing thumb, and small donor foot loss.

  10. Theoretical characteristics of two-dimensional supersonic control surfaces

    NASA Technical Reports Server (NTRS)

    Morrissette, Robert R; Oborny, Lester F

    1951-01-01

    The "Busemann second-order-approximation theory" for the pressure distribution over a two-dimensional airfoil in supersonic flow was used to determine some of the aerodynamic characteristics of uncambered symmetrical parabolic and double-wedge airfoils with leading-edge and trailing-edge flaps. The characteristics presented and discussed in this paper are: flap effectiveness factor, rate of change of hinge-moment coefficient with flap deflection, rate of change of the pitching-moment coefficient with flap deflection, rate of change of the pitching-moment coefficient about the mid chord with flap deflection, and the location of the center of pressure of the airfoil-flap combination.

  11. The Postauricular Helix-based Adipodermal-pedicle Turnover (PHAT) Flap: An Original Single-Stage Technique for Antihelix and Scapha Reconstruction.

    PubMed

    Beustes-Stefanelli, Matthieu; O'Toole, Greg; Schertenleib, Pierre

    2016-01-01

    In reconstructing anterior defects of the ear, postauricular flaps represent a popular option. The pedicle of such transauricular flaps can be superior, inferior, medial, or lateral. The postauricular helix-based adipodermal-pedicle turnover (PHAT) flap is an original single-stage transauricular technique for defects of the antihelix and scapha. Its skin paddle is on the posterior aspect of the ear. Its lateral de-epithelialized pedicle in front of the helix allows for it to easily reach peripheral anterior defects. In cases in which the underlying cartilage is involved, the extended PHAT (ePHAT) flap allows for restoring the contours of the ear without a cartilage graft. Between 2009 and 2011, a PHAT flap was used in 5 cases of defects of the antihelix or the scapha after tumor resection, 3 of which are in an extended version (ePHAT flap). There were no complications and a satisfactory aesthetic result was achieved in all cases. The PHAT flap is an original single-stage procedure for anterior auricular defects located on the antihelix or scapha. The single-layer PHAT flap is indicated in purely skin defect. The triple-layer ePHAT flap includes two subcutaneous extensions which increase its thickness and is indicated to restore the ear contours when cartilage has been removed.

  12. Clinical Comparison of Scapular, Fibular, and Iliac Crest Osseal Free Flaps in Maxillofacial Reconstructions.

    PubMed

    Wilkman, T; Husso, A; Lassus, P

    2018-05-01

    This study compared the three most used composite flaps in maxillofacial reconstructions in our institute. Between 2000 and 2012, a total of 163 patients with mandibular, maxillary, and orbital defects received either scapular, fibular, or iliac crest osseal reconstructions in Helsinki University Hospital, Departments of Plastic Surgery and Maxillofacial Surgery. Data regarding the patient demographics, complications, and outcomes were analyzed. There were 92 deep circumflex iliac artery flaps (56%), followed by 42 scapular (26%) and 29 fibular flaps (18%). The rate of flap loss was the highest in the deep circumflex iliac artery group (p = 0.001). Reconstructions using fibula were fastest (p = 0.001) and had lowest perioperative blood loss (p = 0.013). There were no significant differences in the number of early or late complications between the flaps, but donor site complications were more severe in deep circumflex iliac artery. Osteotomies as well as dental implants were safely performed in all flaps with equal results. All three flaps of this study can be performed with awareness of the deep circumflex iliac artery flap being the least reliable alternative. The knowledge of the advantages and disadvantages of several osseal-free flap alternatives is beneficial in selecting the best suitable method for each individual patient requiring maxillofacial osseal reconstruction.

  13. Impact of different antithrombotics on the microcirculation and viability of perforator-based ischaemic skin flaps in a small animal model.

    PubMed

    Fichter, Andreas M; Ritschl, Lucas M; Robitzky, Luisa K; Wagenpfeil, Stefan; Mitchell, David A; Wolff, Klaus-Dietrich; Mücke, Thomas

    2016-10-21

    The effects of antithrombotic drugs on random and free flap survival have been investigated in the past, but the experimental and clinical results are not in agreement. A perforator-based critical ischaemia model was used to evaluate the effects of different perioperatively administered pharmaceutical agents on tissue ischaemia and to assess the potential additional haemorheological or vasodilative effects of antithrombotics on flap microcirculation. Combined laser Doppler flowmetry and remission spectroscopy revealed an increase in certain microcirculation parameters in most groups in comparison with saline controls, and these changes correlated with flap survival. Clopidogrel and hirudin significantly improved the amount of viable flap tissue in comparison with controls, while unfractioned heparin had a negative effect on flap survival. Low molecular weight heparin, aspirin, pentoxifylline, and hydroxyethyl starch had no impact on the amount of viable flap tissue. A higher complication rate was observed in all experimental groups, but only clopidogrel had a negative impact on the flap viability. Our results add to the body of evidence supporting the conclusion that perioperative antithrombotic treatment improves flap survival. Clopidogrel and hirudin are effective pharmacological agents that significantly increased the viability of perforator-based skin flaps in rats, but at a higher risk of postoperative bleeding.

  14. New method for maximum mobilization of temporalis muscle flap.

    PubMed

    Masic, Tarik; Babajic, Emina; Dervisevic, Almir; Hassouba, Mahmoud

    2012-01-01

    Pedicled temporalis muscle flap presenting a good flap for closing large craniofacial defects. Careful surgeons usually do not mobilize temporalis muscle flap enough to make appropriate use, fully closure, especially if defect exceeds the median line. Temporalis flap was used in 16 patients, ages ranged between 12 and 76. In all cases defect reconstruction was done by useing new method of extending standard temporal muscle flap. During surgical procedure it is very important to keep periosteal elevator in close contact with the bone. Then, there is no risk for pedicle injury. After vascular pedicle is identified elevating temporal muscle has to be continued by releasing the muscle insertion from the coronoid process. By this way, flap length and arc of rotation is increased. The flap remained viable in all instances. Most of the patients experienced no perioperative complications. There was no major complications or mortality as a result of performed procedures. With this division, flap length was increased at least 2 cm wich is enough for covering defects crossing the midline. Instead of using bilateral temporalis muscle flaps for defect closure, unilateral is sufficient. With this extension of the pedicle length now rotation point is not at the level of the zygomatic arch but lower part mandibular neck.

  15. Levator alae nasi muscle V-Y island flap for nasal tip reconstruction.

    PubMed

    La Padula, Simone; Abbate, Vincenzo; Di Monta, Gianluca; Schonauer, Fabrizio

    2017-03-01

    Nasal tip reconstruction can be very challenging. It requires close attention to skin texture, colour and thickness matching, with the respect of the nasal aesthetic units and symmetry. Flaps are usually preferred to skin grafts where possible. Based on different donor areas, various flaps have been described for reconstruction of this region. Here we present a new V-Y myocutaneous island flap based on the levator alae nasi muscle (LAN muscle) blood supply. This flap may represent an alternative to the nasalis myocutaneous sliding V-Y flap previously described by Rybka. As its pivot point it is located more cranially than the nasalis flap, and it can advance more medially than the Rybka flap, with the possibility of covering larger defects of the nasal tip area, up to 1.8 cm in diameter. Over the past 5 years, 24 patients received nasal tip reconstruction with this flap following the resection of basal cell carcinomas. Good tip projection was maintained, and the aesthetic outcome was satisfactory, with well healed scars. We recommend this technique as an alternative to other flaps for nasal tip defects, especially if paramedian. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  16. Release of hand burn contracture: comparing the ALT perforator flap with the gracilis free flap with split skin graft.

    PubMed

    Misani, M; Zirak, C; Hau, Lê Thua Trung; De Mey, A; Boeckx, W

    2013-08-01

    The use of microsurgery in the management of burn sequelae is not a new idea. According to the properties of various types of free flaps different goals can be achieved or various additional procedures have to be combined. We report the comparison of two different free flaps on a single patient for reconstruction of both upper extremities for burn sequelae. A 1-year-old child sustained severe burns on both hands, arms and thorax and was initially only treated conservatively. This resulted in severe contractures. At the age of 4-years a free gracilis flap was selected for reconstruction of his left hand and a free anterolateral thigh flap for the right hand. We noticed a better functional and esthetic result for the gracilis flap associated with a shorter operative time and a minor donor site morbidity. The intraoperative technique and time, postoperative complications, functional and esthetic results and donor site morbidities were studied in the two types of flaps chosen. A review of literature was also performed. Our experience reported a better success of the gracilis muscle flap covered with a split skin graft compared to the anterolateral thigh flap in the reconstruction of hand function after severe burn sequelae. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  17. Noncontact diffuse optical assessment of blood flow changes in head and neck free tissue transfer flaps

    NASA Astrophysics Data System (ADS)

    Huang, Chong; Radabaugh, Jeffrey P.; Aouad, Rony K.; Lin, Yu; Gal, Thomas J.; Patel, Amit B.; Valentino, Joseph; Shang, Yu; Yu, Guoqiang

    2015-07-01

    Knowledge of tissue blood flow (BF) changes after free tissue transfer may enable surgeons to predict the failure of flap thrombosis at an early stage. This study used our recently developed noncontact diffuse correlation spectroscopy to monitor dynamic BF changes in free flaps without getting in contact with the targeted tissue. Eight free flaps were elevated in patients with head and neck cancer; one of the flaps failed. Multiple BF measurements probing the transferred tissue were performed during and post the surgical operation. Postoperative BF values were normalized to the intraoperative baselines (assigning "1") for the calculation of relative BF change (rBF). The rBF changes over the seven successful flaps were 1.89±0.15, 2.26±0.13, and 2.43±0.13 (mean±standard error), respectively, on postoperative days 2, 4, and 7. These postoperative values were significantly higher than the intraoperative baseline values (p<0.001), indicating a gradual recovery of flap vascularity after the tissue transfer. By contrast, rBF changes observed from the unsuccessful flaps were 1.14 and 1.34, respectively, on postoperative days 2 and 4, indicating less flow recovery. Measurement of BF recovery after flap anastomosis holds the potential to act early to salvage ischemic flaps.

  18. Point vortex model for prediction of sound generated by a wing with flap interacting with a passing vortex.

    PubMed

    Manela, A; Huang, L

    2013-04-01

    Acoustic signature of a rigid wing, equipped with a movable downstream flap and interacting with a line vortex, is studied in a two-dimensional low-Mach number flow. The flap is attached to the airfoil via a torsion spring, and the coupled fluid-structure interaction problem is analyzed using thin-airfoil methodology and application of the emended Brown and Michael equation. It is found that incident vortex passage above the airfoil excites flap motion at the system natural frequency, amplified above all other frequencies contained in the forcing vortex. Far-field radiation is analyzed using Powell-Howe analogy, yielding the leading order dipole-type signature of the system. It is shown that direct flap motion has a negligible effect on total sound radiation. The characteristic acoustic signature of the system is dominated by vortex sound, consisting of relatively strong leading and trailing edge interactions of the airfoil with the incident vortex, together with late-time wake sound resulting from induced flap motion. In comparison with the counterpart rigid (non-flapped) configuration, it is found that the flap may act as sound amplifier or absorber, depending on the value of flap-fluid natural frequency. The study complements existing analyses examining sound radiation in static- and detached-flap configurations.

  19. Refining the intrinsic chimera flap: a review.

    PubMed

    Agarwal, Jayant P; Agarwal, Shailesh; Adler, Neta; Gottlieb, Lawrence J

    2009-10-01

    Reconstruction of complex tissue deficiencies in which each missing component is in a different spatial relationship to each other can be particularly challenging, especially in patients with limited recipient vessels. The chimera flap design is uniquely suited to reconstruct these deformities. Chimera flaps have been previously defined in many ways with 2 main categories: prefabricated or intrinsic. Herein we attempt to clarify the definition of a true intrinsic chimeric flap and provide examples of how these constructs provide a method for reconstruction of complex defects. The versatility of the intrinsic chimera flap and its procurement from 7 different vascular systems is described. A clarification of the definition of a true intrinsic chimera flap is described. In addition, construction of flaps from the lateral femoral circumflex, deep circumflex iliac, inferior gluteal, peroneal, subscapular, thoracodorsal, and radial arterial systems is described to showcase the versatility of these chimera flaps. A true intrinsic chimera flap must consist of more than a single tissue type. Each of the tissue components receives its blood flow from separate vascular branches or perforators that are connected to a single vascular source. These vascular branches must be of appropriate length to allow for insetting with 3-dimensional spatial freedom. There are a multitude of sites from which true intrinsic chimera flaps may be harvested.

  20. Membrane Assisted Palatal Fistula Closure in a Cleft Palate Patient: A Novel Technique.

    PubMed

    Reddy, G Siva Prasad; Reddy, G Venkateshwara; Sree, P Karuna; Reddy, K Sravan Kumar; Reddy, P Amarnath

    2016-03-01

    Palatal fistula following cleft palate repair, is one of the considerable complications and remains a challenging problem to the surgeons. The reported recurrence rate of the fistula is between 33% to 37%. Due to fibrosis and poor vascularity of adjacent tissues, high recurrence rates are typical. Closure of palatal fistulas can be achieved by different surgical techniques like local, regional and distant flaps, local turnover flaps, pedicled flaps from oral mucosa, buccal fat pad flaps, inter-positional cartilage grafts can be utilized for management of small fistulas. For larger fistualas, tongue flaps, temporalis muscle flaps, musculomucosal flaps, nasal septal flaps and free flaps can be used. These procedures are often cumbersome and leave a raw nasal or oral surface, which may increase the incidence of postoperative problems or some flaps can be bulky and may require a second-stage procedure. Different synthetic materials such as alloderm, Poly-D and L-Lactic Acid or "PdLLA" and collagen membrane are used in multilayer repair represented by the nasal mucosa, the inter-positional graft and oral mucosa. These interpositional grafts provide a scaffold for in growth of tissues, revascularization and mucosal epithelialization. We present a case of closure of an oronasal fistula, using resorbable collagen membrane in three layered repair to avoid recurrence.

  1. Noncontact diffuse optical assessment of blood flow changes in head and neck free tissue transfer flaps

    PubMed Central

    Huang, Chong; Radabaugh, Jeffrey P.; Aouad, Rony K.; Lin, Yu; Gal, Thomas J.; Patel, Amit B.; Valentino, Joseph; Shang, Yu; Yu, Guoqiang

    2015-01-01

    Abstract. Knowledge of tissue blood flow (BF) changes after free tissue transfer may enable surgeons to predict the failure of flap thrombosis at an early stage. This study used our recently developed noncontact diffuse correlation spectroscopy to monitor dynamic BF changes in free flaps without getting in contact with the targeted tissue. Eight free flaps were elevated in patients with head and neck cancer; one of the flaps failed. Multiple BF measurements probing the transferred tissue were performed during and post the surgical operation. Postoperative BF values were normalized to the intraoperative baselines (assigning “1”) for the calculation of relative BF change (rBF). The rBF changes over the seven successful flaps were 1.89±0.15, 2.26±0.13, and 2.43±0.13 (mean±standard error), respectively, on postoperative days 2, 4, and 7. These postoperative values were significantly higher than the intraoperative baseline values (p<0.001), indicating a gradual recovery of flap vascularity after the tissue transfer. By contrast, rBF changes observed from the unsuccessful flaps were 1.14 and 1.34, respectively, on postoperative days 2 and 4, indicating less flow recovery. Measurement of BF recovery after flap anastomosis holds the potential to act early to salvage ischemic flaps. PMID:26187444

  2. Heart rate and estimated energy expenditure of flapping and gliding in black-browed albatrosses.

    PubMed

    Sakamoto, Kentaro Q; Takahashi, Akinori; Iwata, Takashi; Yamamoto, Takashi; Yamamoto, Maki; Trathan, Philip N

    2013-08-15

    Albatrosses are known to expend only a small amount of energy during flight. The low energy cost of albatross flight has been attributed to energy-efficient gliding (soaring) with sporadic flapping, although little is known about how much time and energy albatrosses expend in flapping versus gliding during cruising flight. Here, we examined the heart rates (used as an instantaneous index of energy expenditure) and flapping activities of free-ranging black-browed albatrosses (Thalassarche melanophrys) to estimate the energy cost of flapping as well as time spent in flapping activities. The heart rate of albatrosses during flight (144 beats min(-1)) was similar to that while sitting on the water (150 beats min(-1)). In contrast, heart rate was much higher during takeoff and landing (ca. 200 beats min(-1)). Heart rate during cruising flight was linearly correlated with the number of wing flaps per minute, suggesting an extra energy burden of flapping. Albatrosses spend only 4.6±1.4% of their time flapping during cruising flight, which was significantly lower than during and shortly after takeoff (9.8±3.5%). Flapping activity, which amounted to just 4.6% of the time in flight, accounted for 13.3% of the total energy expenditure during cruising flight. These results support the idea that albatrosses achieve energy-efficient flight by reducing the time spent in flapping activity, which is associated with high energy expenditure.

  3. Geometric analysis of the V-Y advancement flap and its clinical applications.

    PubMed

    Andrades, Patricio R; Calderon, Wilfredo; Leniz, Patricio; Bartel, German; Danilla, Stefan; Benitez, Susana

    2005-05-01

    Geometry is fundamental in the comprehension of local flap design. The purpose of this study was to discuss the differences between the V-Y advancement flap and other local flaps, understand its geometry, and analyze its clinical applications. The analysis was based on qualitative measurements of an injury, taking into consideration the following dimensions: largest diameter, shortest diameter, and depth. Standardization of the flap design consisted of directing its advancement over the shortest diameter and making the V base match the size of the largest diameter. The flap was analyzed in two planes: the horizontal plane includes the V-Y design and the vertical plane includes the flap pedicle. The height of the flap can be obtained by simple trigonometry, taking into consideration the largest diameter and alpha angle in the horizontal plane. In the vertical plane, where the pedicle and pivot plane are positioned, for known shortest diameter and depth, the final depth of the pivot plane can be calculated using Pythagoras' principles. This analysis was applied to 25 patients with adequate skin coverage at follow-up. A correction factor was added to reduce the overdeepening of the vertical plane calculations. The final concepts for clinical application in the classic deep pedicle V-Y flap design are to calculate the length of the V by modifying the alpha angle and to move the pivot plane deeper to accomplish optimal flap movement. Using these principles, tension-free closure of the Y and appropriate advancement of the flap are obtained.

  4. Availability of the lateral calcaneal region as a donor site of free flaps.

    PubMed

    Cho, Seung Woo; Park, Ji Ung; Kwon, Sung Tack

    2017-09-01

    Various methods have been used for the coverage of soft-tissue defects, such as local and free flaps, as well as perforator flaps performed using even supermicrosurgery. However, the techniques have some limitations regarding flap size and location when used to reconstruct small defects. We introduced the lateral calcaneal region as a donor site for free flaps in order to overcome these disadvantages and presented the results from a series of cases. A retrospective chart review was performed on 10 patients with small soft-tissue defects who underwent reconstruction with a lateral calcaneal free flap between January 2011 and May 2014. The reconstruction was performed on the defects at medial and lateral plantar area, dorsum of the foot, great toes and preauricular area. The size of the flaps ranged from 2.5 × 2.5 cm to 4.5 × 4.5 cm. The flaps exhibited complete survival in five cases. Partial necrosis occurred in three cases, two cases healed with secondary intention, and one case required a skin graft. The donor sites were treated with skin grafts and healed completely, with no complications. Lateral calcaneal free flaps have several advantages, such as anatomically constant pedicles, a pliable and thin texture, and the ability to be used as sensory flaps. They therefore represent an alternative option when conventional local or free flaps are not suitable, especially in cases of small defects. © 2016 Wiley Periodicals, Inc. Microsurgery 37:494-501, 2017. © 2016 Wiley Periodicals, Inc.

  5. Myeloid Cell 5-Lipoxygenase Activating Protein Modulates the Response to Vascular Injury

    PubMed Central

    Yu, Zhou; Ricciotti, Emanuela; Miwa, Takashi; Liu, Shulin; Ihida-Stansbury, Kaori; Landersberg, Gavin; Jones, Peter L.; Scalia, Rosario; Song, Wenchao; Assoian, Richard K.; FitzGerald, Garret A.

    2013-01-01

    Rationale Human genetics have implicated the 5- lipoxygenase (5-LO) enzyme in the pathogenesis of cardiovascular disease and an inhibitor of the 5-LO activating protein (FLAP) is in clinical development for asthma. Objective Here we determined whether FLAP deletion modifies the response to vascular injury. Methods and Results Vascular remodeling was characterized 4 weeks after femoral arterial injury in FLAP knockout (FLAP KO) mice and wild type (WT) controls. Both neointimal hyperplasia and the intima/media ratio of the injured artery were significantly reduced in the FLAP KOs while endothelial integrity was preserved. Lesional myeloid cells were depleted and vascular smooth muscle cell (VSMC) proliferation, as reflected by bromodeoxyuridine (BrdU) incorporation, was markedly attenuated by FLAP deletion. Inflammatory cytokine release from FLAP KO macrophages was depressed and their restricted ability to induce VSMC migration ex vivo was rescued with leukotriene B4 (LTB4). FLAP deletion restrained injury and attenuated upregulation of the extracellular matrix protein, tenascin C (TNC), which affords a scaffold for VSMC migration. Correspondingly, the phenotypic modulation of VSMC to a more synthetic phenotype, reflected by morphological change, loss of α-smooth muscle cell actin and upregulation of vascular cell adhesion molecule (VCAM) -1 was also suppressed in FLAP KO mice. Transplantation of FLAP replete myeloid cells rescued the proliferative response to vascular injury. Conclusion Expression of lesional FLAP in myeloid cells promotes LTB4 dependent VSMC phenotypic modulation, intimal migration and proliferation. PMID:23250985

  6. The "chimeric" trapezius muscle and fasciocutaneous flap (dorsal scapular artery perforator flap): a new design for complex 3-dimensional defects.

    PubMed

    Rozen, Warren M; Fox, Carly M; Leong, James; Morsi, Adel

    2013-11-01

    Multiple variations of the musculocutaneous trapezius flap have been described, each of which use a single composite musculocutaneous unit in their designs. The limitation of such designs is the ability to use the components in a 3-dimensional manner, with only 1 vector existing in the geometry of the musculocutaneous unit. A review of the literature was undertaken with regard to designs of the musculocutaneous trapezius flap, and we present a new technique for flap design. With identification of individual perforators to each of the muscle and fasciocutaneous portions of the trapezius flap, the 2 components can act in a chimeric fashion, able to fill both a deep and complex 3-dimensional space while covering the wound with robust skin. A range of flap designs have been described, including transverse, oblique, and vertical skin paddles accompanying the trapezius muscle. We describe a technique with which a propeller-style skin paddle based on a cutaneous perforator can be raised in any orientation with respect to the underlying muscle. In a presented case, separation of the muscular and fasciocutaneous components of the trapezius flap was able to obliterate dead space around exposed cervicothoracic spinal metalwork and obtain robust wound closure in a patient with previous radiotherapy. This concomitant use of a muscle and fasciocutaneous perforator flap based on a single perforator, a so-called chimeric perforator flap, is a useful modification to trapezius musculocutaneous flap design.

  7. Use of the rectus abdominis muscle for abdominal stoma sphincter construction: an anatomical feasibility study.

    PubMed

    Bardoel, J W; Stadelmann, W K; Tobin, G R; Werker, P M; Stremel, R W; Kon, M; Barker, J H

    2000-02-01

    Permanent fecal abdominal stomas significantly decrease quality of life. Previous attempts to create continent stomas by using dynamic myoplasty procedures have resulted in disappointing outcomes, primarily owing to denervation atrophy of the muscle flap that was used in the creation of the sphincter and because of muscle fatigue resulting from continuous electrical stimulation that is received by the flap to force contraction. On the basis of these problems, we designed two separate studies: an anatomical study addressing flap denervation and a functional study addressing muscle fatigue. The present study addresses the first topic and was designed to develop a rectus abdominis muscle flap into a sphincter that was anatomically situated to create a stoma while preserving as much innervation as possible. In 24 rectus abdominis muscles of human cadavers, the neurovascular anatomy was defined, then the anatomical feasibility of two different muscle flap configurations was considered. The flaps investigated were the peninsula flap and island flap designs, with both using the most caudal segment of the rectus abdominis muscle in construction of the sphincter. Neither flap design required the killing of a nerve for stoma sphincter creation, resulting in minimal muscle denervation. The conclusion of our comparison was that the above, in conjunction with other features of the island flap design, such as muscle overlap after sphincter formation and abdominal wall positioning of the sphincter, made the island flap design better suited to stoma sphincter construction.

  8. [Repair of pressure sores over ischial tuberosity with long head of biceps femoris muscle flap combined with semi-V posterior thigh fasciocutaneous flap].

    PubMed

    Hai, Heng-lin; Shen, Chuan-an; Chai, Jia-ke; Li, Hua-tao

    2012-02-01

    To explore the clinical effect of transplantation of the long head of biceps femoris muscle flap in combination with semi-V posterior thigh fasciocutaneous flap for repair of pressure sores over ischial tuberosity. Eight patients with 10 deep pressure sores over ischial tuberosity were admitted to the First Affiliated Hospital to the PLA General Hospital and the 98th Hospital of PLA from April 2004 to June 2010. The wounds measured from 2 cm × 2 cm to 6 cm × 4 cm were covered with the long head of biceps femoris muscle flap and semi-V posterior thigh fasciocutaneous flap (ranged from 10 cm × 6 cm to 13 cm × 8 cm). The condition of flaps was observed and followed up for a long time. All flaps survived. Nine wounds healed by first intention. Subcutaneous accumulation of fluids occurred in one wound with formation of a sinus at drainage site, and it healed after dressing change for 25 days. Patients were followed up for 7 to 34 months. Sore recurred in one patient 9 months after surgery, and it was successfully repaired with the same flap for the second time. Flaps in the other 7 patients appeared satisfactory with soft texture and without ulceration. This combined flap is easy in formation and transfer, and it causes little side injury with good resistance against pressure. It is a new method for repair of pressure sore over sacral region.

  9. Preoperative radiation and free flap outcomes for head and neck reconstruction: a systematic review and meta-analysis.

    PubMed

    Herle, Pradyumna; Shukla, Lipi; Morrison, Wayne A; Shayan, Ramin

    2015-03-01

    There is a general consensus among reconstructive surgeons that preoperative radiotherapy is associated with a higher risk of flap failure and complications in head and neck surgery. Opinion is also divided regarding the effects of radiation dose on free flap outcomes and timing of preoperative radiation to minimize adverse outcomes. Our meta-analysis will attempt to address these issues. A systematic review of the literature was conducted in concordance to PRISMA protocol. Data were combined using STATA 12 and Open Meta-Analyst software programmes. Twenty-four studies were included comparing 2842 flaps performed in irradiated fields and 3491 flaps performed in non-irradiated fields. Meta-analysis yielded statistically significant risk ratios for flap failure (RR 1.48, P = 0.004), complications (RR 1.84, P < 0.001), reoperation (RR 2.06, P < 0.001) and fistula (RR 2.05, P < 0.001). Mean radiation dose demonstrated a trend towards increased risk of flap failure, but this was not statistically significant. On subgroup analysis, flaps with >60 Gy radiation had a non-statistically significant higher risk of flap failure (RR 1.61, P = 0.145). Preoperative radiation is associated with a statistically significant increased risk of flap complications, failure and fistula. Preoperative radiation in excess of 60 Gy after radiotherapy represents a potential risk factor for increased flap loss and should be avoided where possible. © 2014 Royal Australasian College of Surgeons.

  10. A new A-scan ultrasonoscope.

    PubMed

    Bronson, N R

    1984-05-01

    A new A-mode biometry system for determining axial length measurements of the eye has been developed that incorporates a soft-membrane transducer. The soft transducer decreases the risk of indenting the cornea with the probe resulting in inaccurate measurements. A microprocessor evaluates echo patterns and determines whether or not axial alignment has been obtained, eliminating possible user error. The new A-scan requires minimal user skill and can be used successfully by both physician and technician.

  11. System and method for engine combustion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sczomak, David P.; Gallon, Robert J.; Solomon, Arun S.

    A combustion system for use with one or more cylinder bores of an internal combustion engine includes at least one cylinder head defining first and second intake ports in fluid communication with the one or more cylinder bores. A flap is adjustably connected to the at least one cylinder head. The flap includes a first flap portion cooperating with the first intake port extending from an arm and a second flap portion cooperating with the second intake port extending from the arm and disposed adjacent the first flap portion. A controller in electrical communication with an actuator monitors the conditionmore » of the engine and actuates the flap to position the first and second flap portions between first and second positions to create a first combustion condition and a second combustion condition.« less

  12. Reduction of Flap Side Edge Noise - the Blowing Flap

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V.; Brooks, THomas F.

    2005-01-01

    A technique to reduce the noise radiating from a wing-flap side edge is being developed. As an airplane wing with an extended flap is exposed to a subsonic airflow, air is blown outward through thin rectangular chord-wise slots at various locations along the side edges and side surface of the flap to weaken and push away the vortices that originate in that region of the flap and are responsible for important noise emissions. Air is blown through the slots at up to twice the local flow velocity. The blowing is done using one or multiple slots, where a slot is located along the top, bottom or side surface of the flap along the side edge, or also along the intersection of the bottom (or top) and side surfaces.

  13. Wind tunnel tests of the GA(W)-2 airfoil with 20% aileron, 25% slotted flap, 30% Fowler flap and 10% slot-lip spoiler

    NASA Technical Reports Server (NTRS)

    Wentz, W. H., Jr.

    1977-01-01

    Two dimensional wind tunnel tests were conducted for the GA(W)-2 airfoil section with: 20% aileron, 25% slotted flap; 30% Fowler flap, and 10% slot-lip spoiler. All tests were conducted at a Reynolds number of 2,200,000 and a Mach Number of 0.13. In addition to force measurements, tuft studies were conducted for the slotted and Fowler flap configurations. Aileron and spoiler hinge moments were obtained by integration of surface pressure measurements. Tests results show that a value of 3.82 was obtained with 30% Fowler flap. Aileron control effectiveness and hinge moments were similar to other airfoils. The slot-lip spoiler provided powerful, positive roll control at all flap settings.

  14. Latissimus dorsi (LD) free flap and reconstruction plate used for extensive maxillo-mandibular reconstruction after tumour ablation.

    PubMed

    Li, Bo-Han; Jung, Hun Jong; Choi, Sung-Won; Kim, Soung-Min; Kim, Myung-Jin; Lee, Jong-Ho

    2012-12-01

    The purpose of this study was to consider the indications and evaluate the clinical advantages and disadvantages including, results and complications, of immediate reconstruction using a latissimus dorsi (LD) free flap and reconstruction plate (R-plate) in advanced oro-mandibular tumour resection. Our cohort included 116 patients who underwent LD free flap and R-plate reconstruction. Flap survival, postoperative function, donor/recipient site complication and aesthetics were evaluated. Our series demonstrated a 99.1% flap survival rate. One case required a contralateral LD free flap reconstruction after the initial flap failed due to pedicle kinking. Twelve patients needed the plate to be removed and replaced (n=4, plate fracture; n=2, plate exposure) or definite reconstruction with free fibular flap and implant installation. Donor site complications included seroma accumulation, scarring, and discomfort of the shoulder girdle. The size of the skin paddle ranged from 6 × 10 cm to 12 × 18 cm (12 were double paddled).The facial contour was acceptable without sagging of the flap. The flap was tolerant to irradiation and was resistant to the exposure of the plate at the symphyseal arch. Our series of primary reconstruction with LD free flaps and R-plates showed the retention of mandibular function and the reconstruction of considerably large soft tissue can be achieved successfully. This reconstruction scheme can be indicated for large-volume defects in the oro-mandibular area when the area cannot be covered by a single osteocutaneous free flap, has undergone extensive oncologic resection for advanced or high recurrence rate malignancy and when immediate postoperative chemotherapy and/or irradiation is necessary. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Distally based sural neuro-fasciocutaneous perforator flap for foot and ankle reconstruction: Surgical modifications for flap pedicle and donor site closure without skin graft.

    PubMed

    Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan

    2018-02-01

    The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.

  16. Reconstruction Techniques of Choice for the Facial Cosmetic Units.

    PubMed

    Russo, F; Linares, M; Iglesias, M E; Martínez-Amo, J L; Cabo, F; Tercedor, J; Costa-Vieira, R; Toledo-Pastrana, T; Ródenas, J M; Leis, V

    2017-10-01

    A broad range of skin flaps can be used to repair facial surgical defects after the excision of a tumor. The aim of our study was to develop a practical guideline covering the most useful skin grafts for each of the distinct facial cosmetic units. This was a multicenter study in which 10 dermatologists with extensive experience in reconstructive surgery chose their preferred technique for each cosmetic unit. The choice of flaps was based on personal experience, taking into account factors such as suitability of the reconstruction technique for the specific defect, the final cosmetic result, surgical difficulty, and risk of complications. Each dermatologist proposed 2 flaps in order of preference for each cosmetic subunit. A score of 10 was given to the first flap and a score of 5 to the second. The total score obtained for each of the options proposed by the participating dermatologists was used to draw up a list of the 3 best grafts for each site. There was notable unanimity of criteria among most of the dermatologists for reconstructive techniques such as the glabellar flap for defects of the medial canthus of the eye, the bilateral advancement flag flap or H flap for the forehead, the rotary door flap for the auricle of the ear, the Mustarde flap for the infraorbital cheek, the O-Z rotation flap for the scalp, the Tenzel flap for the lower eyelid, and the island flap for the upper lip. The results of this study will be useful as a practical guide to choosing the best reconstruction technique for each of the facial cosmetic units. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Salvage of Ear Framework Exposure in Total Auricular Reconstruction.

    PubMed

    Kim, Young Soo; Yun, In Sik; Chung, Seum

    2017-02-01

    One of the most common complications of total auricular reconstruction is delayed wound healing, which results in skin necrosis and exposure of the ear framework. Various options exist for salvage of the exposed ear framework. From January 2009 to May 2014, 149 patients underwent total auricular reconstruction using an autogenous cartilage framework or porous polyethylene framework (Medpor; Stryker, USA). An autogenous cartilage framework was used in 48 patients, and a Medpor framework was used in 101 cases. Three cases of framework exposure (3/48, 6.3%) were observed among the patients treated with an autogenous cartilage framework. In contrast, framework exposure took place in 11 patients who were treated with a Medpor framework (11/101, 10.9%). Depending on the method of total ear reconstruction and the location of exposure, the authors used local skin flaps, temporoparietal fascia flaps, deep temporal fascia (DTF) flaps, or mastoid fascia (MF) flaps with skin grafting. Among the 11 patients who experienced framework exposure after being treated with a Medpor framework, a DTF flap with skin grafting was used in 6 patients and an MF flap with skin grafting in 6 patients; 1 patient was treated with both a DTF flap and an MF flap. All 3 cases of cartilage framework exposure were salvaged using a temporoparietal fascia flap with skin grafting, and a local skin flap was used in 1 case. In all 3 cases, the exposed framework was completely covered with the flap, and the reconstructed ears showed well-defined convolutions. Salvage of framework exposure remains a challenging issue in total auricular reconstruction. However, appropriate wound management using various flaps allows the reconstructed ear to be safely preserved.

  18. A Single Amino Acid Difference between Mouse and Human 5-Lipoxygenase Activating Protein (FLAP) Explains the Speciation and Differential Pharmacology of Novel FLAP Inhibitors.

    PubMed

    Blevitt, Jonathan M; Hack, Michael D; Herman, Krystal; Chang, Leon; Keith, John M; Mirzadegan, Tara; Rao, Navin L; Lebsack, Alec D; Milla, Marcos E

    2016-06-10

    5-Lipoxygenase activating protein (FLAP) plays a critical role in the metabolism of arachidonic acid to leukotriene A4, the precursor to the potent pro-inflammatory mediators leukotriene B4 and leukotriene C4 Studies with small molecule inhibitors of FLAP have led to the discovery of a drug binding pocket on the protein surface, and several pharmaceutical companies have developed compounds and performed clinical trials. Crystallographic studies and mutational analyses have contributed to a general understanding of compound binding modes. During our own efforts, we identified two unique chemical series. One series demonstrated strong inhibition of human FLAP but differential pharmacology across species and was completely inactive in assays with mouse or rat FLAP. The other series was active across rodent FLAP, as well as human and dog FLAP. Comparison of rodent and human FLAP amino acid sequences together with an analysis of a published crystal structure led to the identification of amino acid residue 24 in the floor of the putative binding pocket as a likely candidate for the observed speciation. On that basis, we tested compounds for binding to human G24A and mouse A24G FLAP mutant variants and compared the data to that generated for wild type human and mouse FLAP. These studies confirmed that a single amino acid mutation was sufficient to reverse the speciation observed in wild type FLAP. In addition, a PK/PD method was established in canines to enable preclinical profiling of mouse-inactive compounds. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  19. Lower Extremity Limb Salvage with Cross Leg Pedicle Flap, Cross Leg Free Flap, and Cross Leg Vascular Cable Bridge Flap.

    PubMed

    Manrique, Oscar J; Bishop, Sarah N; Ciudad, Pedro; Adabi, Kian; Martinez-Jorge, Jorys; Moran, Steven L; Huang, Tony; Vijayasekaran, Aparna; Chen, Shih-Heng; Chen, Hung-Chi

    2018-05-16

     Lower extremity salvage following significant soft tissue loss can be complicated by lack of recipient vessel for free tissue transfer. We describe our experience in lower limb salvage for patients with no recipient vessels with the use of pedicle, free and cable bridge flaps.  A retrospective review from 1985 to 2017 of patients undergoing lower limb salvage using a contralateral pedicle cross leg (PCL) flaps, free cross leg (FCL) flaps, or free cable bridge (FCB) flaps was conducted. Demographics, etiology of the reconstruction, type of flap used, donor-site vessels, defect size, operating time, time of pedicle division, length of hospital stay, time to ambulation, and complications were analyzed.  A total of 53 patients (48 males and 5 females) with an average age of 35 years (range, 29-38 years) were identified. The etiology for the reconstruction was trauma in 52 patients and oncological resection in 1 patient. There were 18 PCL, 25 FCL, and 10 FCB completed. The recipient vessels for all flaps were the posterior tibial artery and vein. The average operating room times for PCL, FCL, and FCB flaps were 4, 9, and 10 hours, respectively. The average length of hospital stay was 5 weeks and average time to ambulation was 4 weeks. The average follow-up time was 7.5 years (range, 3-12 years). Complications encountered were hematoma (six), prolonged pain (six), total flap loss (two), reoperation (five), and infection (four). Limb salvage rates were 96.2%.  When ipsilateral limb vessels are not available, and other reconstructive options have been exhausted, cross leg flaps can be a viable option for limb salvage in the setting of extensive defects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. AdVEGF-All6A+ Preconditioning of Murine Ischemic Skin Flaps Is Comparable to Surgical Delay.

    PubMed

    Gersch, Robert P; Fourman, Mitchell S; Phillips, Brett T; Nasser, Ahmed; McClain, Steve A; Khan, Sami U; Dagum, Alexander B; Bui, Duc T

    2015-08-01

    Surgical flap delay is commonly used in preconditioning reconstructive flaps to prevent necrosis. However, staged procedures are not ideal. Pharmacologic up-regulation of angiogenic and arteriogenic factors before flap elevation poses a nonsurgical approach to improve flap survival. Male Sprague Dawley rats were divided into control (n = 16), surgical delay (Delay), AdNull, AdEgr-1, and AdVEGF (n ≥ 9/group) groups. Delay rats had a 9 cm × 3 cm cranial based pedicle skin flap incised 10 days prior to elevation. Adenoviral groups received 28 intradermal injections (10(9) pu/animal total) throughout the distal two thirds of the flap 1 week prior to elevation. At postoperative day (POD) 0 flaps were elevated and silicone sheeting was placed between flap and wound bed. Perfusion analysis in arbitrary perfusion units of the ischemic middle third of the flap using laser Doppler imaging was conducted preoperatively and on POD 0, 3, and 7. Clinical and histopathologic assessments of the skin flaps were performed on POD 7. AdVEGF (50.8 ± 10.9 APU) and AdEgr-1 (39.3 ± 10.6 APU) perfusion levels were significantly higher than controls (16.5 ± 4.2 APU) on POD 7. Delay models were equivalent to controls (25.9 ± 6.8 APU). AdVEGF and Delay animals showed significantly more viable surface area on POD 7 (14.4 ± 1.3 cm(2), P < 0.01 and 12.4 ± 1.2 cm(2), P < 0.05, respectively) compared with Controls (8.7 ± 0.7 cm(2)). AdVEGF preconditioning resulted in flap survival comparable to surgical delay. Adenoviral preconditioning maintained perfusion levels postoperatively while surgical delay did not.

Top