Sample records for background capsule endoscopy

  1. Capsule endoscopy

    MedlinePlus

    Capsule enteroscopy; Wireless capsule endoscopy; Video capsule endoscopy (VCE); Small bowel capsule endoscopy (SBCE) ... a computer and software turns them into a video. Your provider watches the video to look for ...

  2. Ethical aspects of capsule endoscopy.

    PubMed

    Niv, Yaron

    2008-01-01

    Capsule endoscopy is the most recent innovation in gastrointestinal endoscopy. The capsule contains a video camera that photographs the bowel for 8 h after the capsule has been orally ingested and transmits the images for interpretation to a computerized workstation. Ethical considerations of the use of capsule endoscopy should cover the following main issues: justification of the procedure, its potential benefits and harm, and patient autonomy. Capsule endoscopy has several advantages over traditional endoscopy. The procedure is painless, does not require sedation, is easy to perform and for the first time enables exploration of the entire small bowel at high magnification. However, the clinician cannot control its passive advance along the bowel. In addition, the examination may be incomplete, as the capsule reaches the cecum in only 80% of cases. This paper discusses the problems related to the new endoscopic procedure, the diagnostic yield in comparison with other procedures, proper indications for the procedure, outcome and complications. Copyright 2008 S. Karger AG, Basel.

  3. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis

    PubMed Central

    Palimaka, S; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion

  4. Magnetically guided capsule endoscopy.

    PubMed

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  5. Chromoendoscopy in magnetically guided capsule endoscopy

    PubMed Central

    2013-01-01

    Background Diagnosis of intestinal metaplasia and dysplasia via conventional endoscopy is characterized by low interobserver agreement and poor correlation with histopathologic findings. Chromoendoscopy significantly enhances the visibility of mucosa irregularities, like metaplasia and dysplasia mucosa. Magnetically guided capsule endoscopy (MGCE) offers an alternative technology for upper GI examination. We expect the difficulties of diagnosis of neoplasm in conventional endoscopy to transfer to MGCE. Thus, we aim to chart a path for the application of chromoendoscopy on MGCE via an ex-vivo animal study. Methods We propose a modified preparation protocol which adds a staining step to the existing MGCE preparation protocol. An optimal staining concentration is quantitatively determined for different stain types and pathologies. To that end 190 pig stomach tissue samples with and without lesion imitations were stained with different dye concentrations. Quantitative visual criteria are introduced to measure the quality of the staining with respect to mucosa and lesion visibility. Thusly determined optimal concentrations are tested in an ex-vivo pig stomach experiment under magnetic guidance of an endoscopic capsule with the modified protocol. Results We found that the proposed protocol modification does not impact the visibility in the stomach or steerability of the endoscopy capsule. An average optimal staining concentration for the proposed protocol was found at 0.4% for Methylene blue and Indigo carmine. The lesion visibility is improved using the previously obtained optimal dye concentration. Conclusions We conclude that chromoendoscopy may be applied in MGCE and improves mucosa and lesion visibility. Systematic evaluation provides important information on appropriate staining concentration. However, further animal and human in-vivo studies are necessary. PMID:23758801

  6. Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis

    PubMed Central

    Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron

    2015-01-01

    Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule

  7. Capsule endoscopy: no longer limited to the small bowel.

    PubMed

    Niv, Yaron

    2010-03-01

    Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.

  8. Effect of small bowel preparation with simethicone on capsule endoscopy*

    PubMed Central

    Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling

    2009-01-01

    Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed. PMID:19198022

  9. Capsule endoscopy in the diagnosis of Crohn's disease.

    PubMed

    Niv, Yaron

    2013-01-01

    Crohn's disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn's disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn's disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn's disease. Recently, we have developed and validated the Capsule Endoscopy Crohn's Disease Activity Index (also known as the Niv score) for Crohn's disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn's ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn's disease.

  10. Ultrasound capsule endoscopy: sounding out the future

    PubMed Central

    Stewart, Fraser; Lay, Holly; Cummins, Gerard; Newton, Ian P.; Desmulliez, Marc P. Y.; Steele, Robert J. C.; Näthke, Inke; Cochran, Sandy

    2017-01-01

    Video capsule endoscopy (VCE) has been of immense benefit in the diagnosis and management of gastrointestinal (GI) disorders since its introduction in 2001. However, it suffers from a number of well recognized deficiencies. Amongst these is the limited capability of white light imaging, which is restricted to analysis of the mucosal surface. Current capsule endoscopes are dependent on visual manifestation of disease and limited in regards to transmural imaging and detection of deeper pathology. Ultrasound capsule endoscopy (USCE) has the potential to overcome surface only imaging and provide transmural scans of the GI tract. The integration of high frequency microultrasound (µUS) into capsule endoscopy would allow high resolution transmural images and provide a means of both qualitative and quantitative assessment of the bowel wall. Quantitative ultrasound (QUS) can provide data in an objective and measurable manner, potentially reducing lengthy interpretation times by incorporation into an automated diagnostic process. The research described here is focused on the development of USCE and other complementary diagnostic and therapeutic modalities. Presently investigations have entered a preclinical phase with laboratory investigations running concurrently. PMID:28567381

  11. Capsule endoscopy in the diagnosis of Crohn’s disease

    PubMed Central

    Niv, Yaron

    2013-01-01

    Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score) for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing mucosal status, capsule endoscopy will provide important information about the course and outcome of Crohn’s disease. PMID:23818810

  12. Safety of capsule endoscopy using human body communication in patients with cardiac devices.

    PubMed

    Chung, Joo Won; Hwang, Hye Jin; Chung, Moon Jae; Park, Jeong Youp; Pak, Hui-Nam; Song, Si Young

    2012-06-01

    The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

  13. Capsule endoscopy: impact on clinical decision making in patients with suspected small bowel bleeding.

    PubMed

    Gubler, C; Fox, M; Hengstler, P; Abraham, D; Eigenmann, F; Bauerfeind, P

    2007-12-01

    Capsule endoscopy is widely used for diagnosis of small-bowel disease; however, the impact of capsule endoscopy on clinical management remains uncertain. We conducted a prospective study of the impact capsule endoscopy on clinical management decisions in 128 patients with suspected small-bowel pathology. Prior to performing each procedure the gastroenterologist predicted the findings of capsule endoscopy and further management based on the clinical history and previous investigations. This prediction was compared with the actual results of capsule endoscopy and the following investigative and therapeutic management. The actual findings of capsule endoscopy and the further management were consistent with clinical prediction in 93/128 patients (73 %) and, irrespective of capsule endoscopy findings, no further procedures were required in 80 % of these patients. In 13 patients (10 %), gastric or colonic pathology was discovered that had not been detected on prior gastroscopy or colonoscopy. Thus, capsule endoscopy findings in the small bowel changed clinical management in 22 patients (17 %). In 4 patients, positive findings on capsule endoscopy that had not been predicted by the examiner prompted referral for abdominal surgery. Conversely, planned surgery was canceled in four other patients. In this series of patients referred for capsule endoscopy, small-bowel findings and appropriate clinical management were predicted on clinical grounds alone in approximately three-quarters of patients. Repetition of standard upper and lower endoscopy may be useful in many patients prior to small-bowel imaging. Referral for capsule endoscopy should take into account whether the findings will impact on clinical management; however, capsule endoscopy is mandatory in patients in whom surgery for small-bowel bleeding is intended.

  14. Role of capsule endoscopy in inflammatory bowel disease.

    PubMed

    Kopylov, Uri; Seidman, Ernest G

    2014-02-07

    Videocapsule endoscopy (VCE) has revolutionized our ability to visualize the small bowel mucosa. This modality is a valuable tool for the diagnosis of obscure small bowel Crohn's disease (CD), and can also be used for monitoring of disease activity in patients with established small-bowel CD, detection of complications such as obscure bleeding and neoplasms, evaluation of response to anti-inflammatory treatment and postoperative recurrence following small bowel resection. VCE could also be an important tool in the management of patients with unclassified inflammatory bowel disease, potentially resulting in reclassification of these patients as having CD. Reports on postoperative monitoring and evaluation of patients with ileal pouch-anal anastomosis who have developed pouchitis have recenty been published. Monitoring of colonic inflammatory activity in patients with ulcerative colitis using the recently developed colonic capsule has also been reported. Capsule endoscopy is associated with an excellent safety profile. Although retention risk is increased in patients with small bowel CD, this risk can be significanty decreased by a routine utilization of a dissolvable patency capsule preceding the ingestion of the diagnostic capsule. This paper contains an overview of the current and future clinical applications of capsule endoscopy in inflammatory bowel disease.

  15. Capsule endoscopy: The road ahead

    PubMed Central

    Singeap, Ana-Maria; Stanciu, Carol; Trifan, Anca

    2016-01-01

    Since its introduction into clinical practice 15 years ago, capsule endoscopy (CE) has become the first-line investigation procedure in some small bowel pathologies, and more recently, dedicated esophageal and colon CE have expanded the fields of application to include the upper and lower gastrointestinal disorders. During this time, CE has become increasingly popular among gastroenterologists, with more than 2 million capsule examinations performed worldwide, and nearly 3000 PubMed-listed studies on its different aspects published. This huge interest in CE may be explained by its non-invasive nature, patient comfort, safety, and access to anatomical regions unattainable via conventional endoscopy. However, CE has several limitations which impede its wider clinical applications, including the lack of therapeutic capabilities, inability to obtain biopsies and control its locomotion. Several research groups are currently working to overcome these limitations, while novel devices able to control capsule movement, obtain high quality images, insufflate the gut lumen, perform chromoendoscopy, biopsy of suspect lesions, or even deliver targeted drugs directly to specific sites are under development. Overlooking current limitations, especially as some of them have already been successfully surmounted, and based on the tremendous progress in technology, it is expected that, by the end of next 15 years, CE able to perform both diagnostic and therapeutic procedures will remain the major form of digestive endoscopy. This review summarizes the literature that prognosticates about the future developments of CE. PMID:26755883

  16. Capsule endoscopy: Current practice and future directions

    PubMed Central

    Hale, Melissa F; Sidhu, Reena; McAlindon, Mark E

    2014-01-01

    Capsule endoscopy (CE) has transformed investigation of the small bowel providing a non-invasive, well tolerated means of accurately visualising the distal duodenum, jejunum and ileum. Since the introduction of small bowel CE thirteen years ago a high volume of literature on indications, diagnostic yields and safety profile has been presented. Inclusion in national and international guidelines has placed small bowel capsule endoscopy at the forefront of investigation into suspected diseases of the small bowel. Most commonly, small bowel CE is used in patients with suspected bleeding or to identify evidence of active Crohn’s disease (CD) (in patients with or without a prior history of CD). Typically, CE is undertaken after upper and lower gastrointestinal flexible endoscopy has failed to identify a diagnosis. Small bowel radiology or a patency capsule test should be considered prior to CE in those at high risk of strictures (such as patients known to have CD or presenting with obstructive symptoms) to reduce the risk of capsule retention. CE also has a role in patients with coeliac disease, suspected small bowel tumours and other small bowel disorders. Since the advent of small bowel CE, dedicated oesophageal and colon capsule endoscopes have expanded the fields of application to include the investigation of upper and lower gastrointestinal disorders. Oesophageal CE may be used to diagnose oesophagitis, Barrett’s oesophagus and varices but reliability in identifying gastroduodenal pathology is unknown and it does not have biopsy capability. Colon CE provides an alternative to conventional colonoscopy for symptomatic patients, while a possible role in colorectal cancer screening is a fascinating prospect. Current research is already addressing the possibility of controlling capsule movement and developing capsules which allow tissue sampling and the administration of therapy. PMID:24976712

  17. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    PubMed Central

    2015-01-01

    Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no

  18. Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe

    PubMed Central

    Harris, Lucinda A.; Hansel, Stephanie L.; Rajan, Elizabeth; Srivathsan, Komandoor; Rea, Robert; Crowell, Michael D.; Fleischer, David E.; Pasha, Shabana F.; Gurudu, Suryakanth R.; Heigh, Russell I.; Shiff, Arthur D.; Post, Janice K.; Leighton, Jonathan A.

    2013-01-01

    Background and Study Aims. The presence of an implantable electromechanical cardiac device (IED) has long been considered a relative contraindication to the performance of video capsule endoscopy (CE). The primary aim of this study was to evaluate the safety of CE in patients with IEDs. A secondary purpose was to determine whether IEDs have any impact on images captured by CE. Patients and Methods. A retrospective chart review of all patients who had a capsule endoscopy at Mayo Clinic in Scottsdale, AZ, USA, or Rochester, MN, USA, (January 2002 to June 2010) was performed to identify CE studies done on patients with IEDs. One hundred and eighteen capsule studies performed in 108 patients with IEDs were identified and reviewed for demographic data, method of preparation, and study data. Results. The most common indications for CE were obscure gastrointestinal bleeding (77%), anemia (14%), abdominal pain (5%), celiac disease (2%), diarrhea (1%), and Crohn's disease (1%). Postprocedure assessments did not reveal any detectable alteration on the function of the IED. One patient with an ICD had a 25-minute loss of capsule imaging due to recorder defect. Two patients with LVADs had interference with capsule image acquisition. Conclusions. CE did not interfere with IED function, including PM, ICD, and/or LVAD and thus appears safe. Additionally, PM and ICD do not appear to interfere with image acquisition but LVAD may interfere with capsule images and require that capsule leads be positioned as far away as possible from the IED to assure reliable image acquisition. PMID:23710168

  19. Simethicone for small bowel preparation for capsule endoscopy: a systematic, single-blinded, controlled study.

    PubMed

    Albert, Jörg; Göbel, Christa-Maria; Lesske, Joachim; Lotterer, Erich; Nietsch, Hubert; Fleig, Wolfgang E

    2004-04-01

    Capsule endoscopy is a new imaging method for visualization of the entire small bowel. However, no standardized protocol for bowel preparation for capsule endoscopy has been evaluated. Capsule endoscopy was performed in 36 consecutive patients, all of whom fasted for 12 hours before ingestion of the capsule. Before capsule endoscopy, 18 patients received 80 mg simethicone and 18 had no supplemental medication for bowel preparation. Two observers, both experienced endoscopists, independently reviewed the examinations in a single-blinded and randomly assigned fashion. Mucosal visibility and intraluminal gas bubbles were assessed and graded by both observers. Bowel preparation with simethicone resulted in significantly better visibility because of fewer intraluminal bubbles (p<0.01). Interobserver agreement was excellent (r>/=0.8; k 0.78: 95% CI[0.57, 0.98] ). No adverse effect of simethicone was observed. Simethicone may be added to the routine preparation for capsule endoscopy to improve the visibility of small bowel mucosa.

  20. Effect of small bowel preparation with simethicone on capsule endoscopy.

    PubMed

    Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling

    2009-01-01

    Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.

  1. Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy negative gastrointestinal bleeding

    PubMed Central

    Mylonaki, M; Fritscher-Ravens, A; Swain, P

    2003-01-01

    Background: The development of wireless capsule endoscopy allows painless imaging of the small intestine. Its clinical use is not yet defined. The aim of this study was to compare the clinical efficacy and technical performance of capsule endoscopy and push enteroscopy in a series of 50 patients with colonoscopy and gastroscopy negative gastrointestinal bleeding. Methods: A wireless capsule endoscope was used containing a CMOS colour video imager, transmitter, and batteries. Approximately 50 000 transmitted images are received by eight abdominal aerials and stored on a portable solid state recorder, which is carried on a belt. Push enteroscopy was performed using a 240 cm Olympus video enteroscope. Results: Studies in 14 healthy volunteers gave information on normal anatomical appearances and preparation. In 50 patients with gastrointestinal bleeding and negative colonoscopy and gastroscopy, push enteroscopy was compared with capsule endoscopy. A bleeding source was discovered in the small intestine in 34 of 50 patients (68%). These included angiodysplasia (16), focal fresh bleeding (eight), apthous ulceration suggestive of Crohn’s disease (three), tumour (two), Meckel’s diverticulum (two), ileal ulcer (one), jejunitis (one), and ulcer due to intussusception (one). One additional intestinal diagnosis was made by enteroscopy. The yield of push enteroscopy in evaluating obscure bleeding was 32% (16/50). The capsule identified significantly more small intestinal bleeding sources than push enteroscopy (p<0.05). Patients preferred capsule endoscopy to push enteroscopy (p<0.001). Conclusions: In this study capsule endoscopy was superior to push enteroscopy in the diagnosis of recurrent bleeding in patients who had a negative gastroscopy and colonoscopy. It was safe and well tolerated. PMID:12865269

  2. The history of time for capsule endoscopy.

    PubMed

    Adler, Samuel N

    2017-05-01

    Capsule endoscopy was conceived by inventive minds of good people. In the beginning there was a will to do something for medicine. The idea fomented after a discourse between the talented engineer with his physician friend. It took years to develop the concept. Then excellent engineers created de novo the necessary components to turn the capsule into a viable reality. The story is a tribute to human ingenuity.

  3. Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval.

    PubMed

    Van Weyenberg, Stijn J B; Van Turenhout, Sietze T; Bouma, Gerd; Van Waesberghe, Jan Hein T M; Van der Peet, Donald L; Mulder, Chris J J; Jacobs, Maarten A J M

    2010-03-01

    Capsule retention in the small bowel is a known complication of small-bowel video capsule endoscopy. Surgery is the most frequently used method of capsule retrieval. To determine the incidence and causes of capsule retention and to describe double-balloon endoscopy (DBE) as the primary technique used for capsule retrieval. Retrospective analysis of all video capsule studies was performed at our center, and evaluation of the outcome of DBE was the first method used to retrieve entrapped video capsules. Tertiary referral center. A total of 904 patients who underwent small-bowel video capsule endoscopy. Capsule retrieval by DBE. The number of patients in whom capsule retention occurred and the number of patients in whom an entrapped capsule could be retrieved by using DBE. Capsule retention occurred in 8 patients (incidence 0.88%; 95% CI, 0.41%-1.80%) and caused acute small-bowel obstruction in 6 patients. All retained capsules were successfully removed during DBE. Five patients underwent elective surgery to treat the underlying cause of capsule retention. One patient required emergency surgery because of multiple small-bowel perforations. Retrospective design. In our series, the incidence of capsule retention was low. DBE is a reliable method for removing retained capsules and might prevent unnecessary surgery. If surgery is required, preoperative capsule retrieval allows preoperative diagnosis, adequate staging in case of malignancy, and optimal surgical planning. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  4. Esophageal capsule endoscopy is not the optimal technique to determine the need for primary prophylaxis in patients with cirrhosis

    PubMed Central

    Krok, Karen L.; Wagennar, Rebecca Rankin; Kantsevoy, Sergey V.

    2016-01-01

    Introduction Capsule endoscopy has been suggested as a potential alternative to endoscopy for detection of esophagogastric varices and severe portal hypertensive gastropathy (PHG). The aim of the study was to determine whether PillCam esophageal capsule endoscopy could replace endoscopy for screening purposes. Material and methods Sixty-two patients with cirrhosis with no previous variceal bleeding had PillCam capsule endoscopy and video endoscopy performed on the same day. Sensitivity, specificity, and positive and negative predictive values (PPV, NPV) of capsule endoscopy were compared to endoscopy for the presence and severity of esophageal and gastric varices, PHG and the need for primary prophylaxis. Patients’ preference was assessed by a questionnaire. Results Four (6%) patients were unable to swallow the capsule. Sensitivity, specificity, PPV and NPV of capsule endoscopy for detecting any esophageal varices (92%, 50%, 92%, 50%), large varices (55%, 91%, 75%, 80%), variceal red signs (58%, 87%, 69%, 80%), PHG (95%, 50%, 95%, 50%), and the need for primary prophylaxis (91%, 57%, 78%, 80%) were not optimal, with only moderate agreement (κ) between capsule and upper GI endoscopy. Had only a capsule endoscopy been performed, 12 (21.4%) patients would have received inappropriate treatment. Capsule endoscopy also failed to detect (0/13) gastric varices. The majority of patients ranked capsule endoscopy as more convenient (69%) and their preferred (61%) method. Conclusions Despite the preference expressed by patients for capsule endoscopy, we believe that upper GI endoscopy should remain the preferred screening method for primary prophylaxis. PMID:27186182

  5. Small bowel capsule endoscopy in 2007: Indications, risks and limitations

    PubMed Central

    Rondonotti, Emanuele; Villa, Federica; Mulder, Chris JJ; Jacobs, Maarten AJM; de Franchis, Roberto

    2007-01-01

    Capsule endoscopy has revoluzionized the study of the small bowel by providing a reliable method to evaluate, endoscopically, the entire small bowel. In the last six years several papers have been published exploring the possible role of this examination in different clinical conditions. At the present time capsule endoscopy is generally recommended as a third examination, after negative bidirectional endoscopy, in patients with obscure gastrointestinal bleeding. A growing body of evidence suggests also an important role for this examination in other clinical conditions such as Crohn’s disease, celiac disease, small bowel polyposis syndromes or small bowel tumors. The main complication of this examination is the retention of the device at the site of a previously unknown small bowel stricture. However there are also some other open issues mainly due to technical limitations of this tool (which is not driven from remote control, is unable to take biopsies, to insufflate air, to suck fluids or debris and sometimes to correctly size and locate lesions).The recently developed double balloon enteroscope, owing to its capability to explore a large part of the small bowel and to take targeted biopsies, although being invasive and time consuming, can overcome some limitations of capsule endoscopy. At the present time, in the majority of clinical conditions (i.e. obscure GI bleeding), the winning strategy seems to be to couple these two techniques to explore the small bowel in a painless, safe and complete way (with capsule endoscopy) and to define and treat the lesions identified (with double balloon enteroscopy). PMID:18069752

  6. International core curriculum for capsule endoscopy training courses.

    PubMed

    Fernandez-Urien, Ignacio; Panter, Simon; Carretero, Cristina; Davison, Carolyn; Dray, Xavier; Fedorov, Evgeny; Makins, Richard; Mascarenhas, Miguel; McAlindon, Mark; McNamara, Deirdre; Palmer, Hansa; Rey, Jean Francoise; Saurin, Jean Christophe; Seitz, Uwe; Spada, Cristiano; Toth, Ervin; Wiedbrauck, Felix; Keuchel, Martin

    2017-06-01

    Capsule endoscopy (CE) has become a first-line noninvasive tool for visualisation of the small bowel (SB) and is being increasingly used for investigation of the colon. The European Society of Gastrointestinal Endoscopy (ESGE) guidelines have specified requirements for the clinical applications of CE. However, there are no standardized recommendations yet for CE training courses in Europe. The following suggestions in this curriculum are based on the experience of European CE training courses directors. It is suggested that 12 hours be dedicated for either a small bowel capsule endoscopy (SBCE) or a colon capsule endoscopy (CCE) course with 4 hours for an introductory CCE course delivered in conjunction with SBCE courses. SBCE courses should include state-of-the-art lectures on indications, contraindications, complications, patient management and hardware and software use. Procedural issues require approximately 2 hours. For CCE courses 2.5 hours for theoretical lessons and 3.5 hours for procedural issued are considered appropriate. Hands-on training on reading and interpretation of CE cases using a personal computer (PC) for 1 or 2 delegates is recommended for both SBCE and CCE courses. A total of 6 hours hands-on session- time should be allocated. Cases in a SBCE course should cover SB bleeding, inflammatory bowel diseases (IBD), tumors and variants of normal and cases with various types of polyps covered in CCE courses. Standardization of the description of findings and generation of high-quality reports should be essential parts of the training. Courses should be followed by an assessment of trainees' skills in order to certify readers' competency.

  7. International core curriculum for capsule endoscopy training courses

    PubMed Central

    Fernandez-Urien, Ignacio; Panter, Simon; Carretero, Cristina; Davison, Carolyn; Dray, Xavier; Fedorov, Evgeny; Makins, Richard; Mascarenhas, Miguel; McAlindon, Mark; McNamara, Deirdre; Palmer, Hansa; Rey, Jean Francoise; Saurin, Jean Christophe; Seitz, Uwe; Spada, Cristiano; Toth, Ervin; Wiedbrauck, Felix; Keuchel, Martin

    2017-01-01

    Capsule endoscopy (CE) has become a first-line noninvasive tool for visualisation of the small bowel (SB) and is being increasingly used for investigation of the colon. The European Society of Gastrointestinal Endoscopy (ESGE) guidelines have specified requirements for the clinical applications of CE. However, there are no standardized recommendations yet for CE training courses in Europe. The following suggestions in this curriculum are based on the experience of European CE training courses directors. It is suggested that 12 hours be dedicated for either a small bowel capsule endoscopy (SBCE) or a colon capsule endoscopy (CCE) course with 4 hours for an introductory CCE course delivered in conjunction with SBCE courses. SBCE courses should include state-of-the-art lectures on indications, contraindications, complications, patient management and hardware and software use. Procedural issues require approximately 2 hours. For CCE courses 2.5 hours for theoretical lessons and 3.5 hours for procedural issued are considered appropriate. Hands-on training on reading and interpretation of CE cases using a personal computer (PC) for 1 or 2 delegates is recommended for both SBCE and CCE courses. A total of 6 hours hands-on session- time should be allocated. Cases in a SBCE course should cover SB bleeding, inflammatory bowel diseases (IBD), tumors and variants of normal and cases with various types of polyps covered in CCE courses. Standardization of the description of findings and generation of high-quality reports should be essential parts of the training. Courses should be followed by an assessment of traineesʼ skills in order to certify readers’ competency. PMID:28596986

  8. A review of drug delivery systems for capsule endoscopy.

    PubMed

    Munoz, Fredy; Alici, Gursel; Li, Weihua

    2014-05-01

    The development of a highly controllable drug delivery system (DDS) for capsule endoscopy has become an important field of research due to its promising applications in therapeutic treatment of diseases in the gastrointestinal (GI) tract and drug absorption studies. Several factors need to be considered to establish the minimum requirements for a functional DDS. Environmental factors of the GI tract and also pharmaceutical factors can help determine the requirements to be met by a DDS in an endoscopic capsule. In order to minimize the influence of such factors on the performance of an effective DDS, at least two mechanisms should be incorporated into a capsule endoscope: an anchoring mechanism to control the capsule position and a drug release mechanism to control variables such as the drug release rate, number of doses and amount of drug released. The implementation of such remotely actuated mechanisms is challenging due to several constraints, including the limited space available in a swallowable capsule endoscope and the delicate and complex environment within the GI tract. This paper presents a comprehensive overview of existing DDS. A comparison of such DDS for capsule endoscopy based on the minimum DDS requirements is presented and future work is also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Patient burden and patient preference: comparing magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy.

    PubMed

    Wiarda, Bart M; Stolk, Mark; Heine, Dimitri G N; Mensink, Peter; Thieme, Mai E; Kuipers, Ernst J; Stoker, Jaap

    2013-03-01

    We aimed to prospectively determine patient burden and patient preference for magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy in patients with suspected or known Crohn's disease (CD) or occult gastrointestinal bleeding (OGIB).  Consecutive consenting patients with CD or OGIB underwent magnetic resonance enteroclysis, capsule endoscopy and balloon-assisted enteroscopy. Capsule endoscopy was only performed if magnetic resonance enteroclysis showed no high-grade small bowel stenosis. Patient preference and burden was evaluated by means of standardized questionnaires at five moments in time. From January 2007 until March 2009, 76 patients were included (M/F 31/45; mean age 46.9 years; range 20.0-78.4 years): 38 patients with OGIB and 38 with suspected or known CD. Seventeen patients did not undergo capsule endoscopy because of high-grade stenosis. Ninety-five percent (344/363) of the questionnaires were suitable for evaluation. Capsule endoscopy was significantly favored over magnetic resonance enteroclysis and balloon-assisted enteroscopy with respect to bowel preparation, swallowing of the capsule (compared to insertion of the tube/scope), burden of the entire examination, duration and accordance with the pre-study information. Capsule endoscopy and magnetic resonance enteroclysis were significantly preferred over balloon-assisted enteroscopy for clarity of explanation of the examination, and magnetic resonance enteroclysis was significantly preferred over balloon-assisted enteroscopy for bowel preparation, painfulness and burden of the entire examination. Balloon-assisted enteroscopy was significantly favored over magnetic resonance enteroclysis for insertion of the scope and procedure duration. Pre- and post-study the order of preference was capsule endoscopy, magnetic resonance enteroclysis and balloon-assisted enteroscopy. Capsule endoscopy was preferred to magnetic resonance enteroclysis and balloon-assisted enteroscopy

  10. [Improvement of Digital Capsule Endoscopy System and Image Interpolation].

    PubMed

    Zhao, Shaopeng; Yan, Guozheng; Liu, Gang; Kuang, Shuai

    2016-01-01

    Traditional capsule image collects and transmits analog image, with weak anti-interference ability, low frame rate, low resolution. This paper presents a new digital image capsule, which collects and transmits digital image, with frame rate up to 30 frames/sec and pixels resolution of 400 x 400. The image is compressed in the capsule, and is transmitted to the outside of the capsule for decompression and interpolation. A new type of interpolation algorithm is proposed, which is based on the relationship between the image planes, to obtain higher quality colour images. capsule endoscopy, digital image, SCCB protocol, image interpolation

  11. Contraindications for video capsule endoscopy

    PubMed Central

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm. PMID:28018097

  12. Guidelines for Bowel Preparation before Video Capsule Endoscopy

    PubMed Central

    Song, Hyun Joo; Do, Jae Hyuk; Cha, In Hye; Yang, Chang Hun; Choi, Myung-Gyu; Jeen, Yoon Tae; Kim, Hyun Jung

    2013-01-01

    The preparation for video capsule endoscopy (VCE) of the bowel suggested by manufacturers of capsule endoscopy systems consists only of a clear liquid diet and an 8-hour fast. While there is evidence for a benefit from bowel preparation for VCE, so far there is no domestic consensus on the preparation regimen in Korea. Therefore, we performed this study to recommend guidelines for bowel preparation before VCE. The guidelines on VCE were developed by the Korean Gut Image Study Group, part of the Korean Society of Gastrointestinal Endoscopy. Four key questions were selected. According to our guidelines, bowel preparation with polyethylene glycol (PEG) solution enhances small bowel visualization quality (SBVQ) and diagnostic yield (DY), but it has no effect on cecal completion rate (CR). Bowel preparation with 2 L of PEG solution is similar to that with 4 L of PEG in terms of the SBVQ, DY, and CR of VCE. Bowel preparation with fasting or PEG solution combined with simethicone enhances the SBVQ, but it does not affect the CR of VCE. Bowel preparation with prokinetics does not enhance the SBVQ, DY, or CR of VCE. PMID:23614124

  13. Small intestinal model for electrically propelled capsule endoscopy

    PubMed Central

    2011-01-01

    The aim of this research is to propose a small intestine model for electrically propelled capsule endoscopy. The electrical stimulus can cause contraction of the small intestine and propel the capsule along the lumen. The proposed model considered the drag and friction from the small intestine using a thin walled model and Stokes' drag equation. Further, contraction force from the small intestine was modeled by using regression analysis. From the proposed model, the acceleration and velocity of various exterior shapes of capsule were calculated, and two exterior shapes of capsules were proposed based on the internal volume of the capsules. The proposed capsules were fabricated and animal experiments were conducted. One of the proposed capsules showed an average (SD) velocity in forward direction of 2.91 ± 0.99 mm/s and 2.23 ± 0.78 mm/s in the backward direction, which was 5.2 times faster than that obtained in previous research. The proposed model can predict locomotion of the capsule based on various exterior shapes of the capsule. PMID:22177218

  14. Capsule endoscopy: in search of the ideal image.

    PubMed

    Enns, Robert

    2008-01-01

    Capsule studies can be reviewed by varying rates and speeds; however, the presence of significant debris is frustrating to the reviewer much like the excessive stool that tends to hinder the progress of a colonoscopist. Numerous studies have been published in regards to the advantages of an ideal preparation in the setting of capsule endoscopy. This most recent study by Wei et al. is another study that has demonstrated that a colonic preparation, in this situation, combined with simethicone given just prior to the capsule study results in improved visibility of the mucosa. In theory, this will lead to an improved diagnostic ability to limit excessive reading duration.

  15. Emerging Issues and Future Developments in Capsule Endoscopy

    PubMed Central

    Slawinski, Piotr R.; Obstein, Keith L.; Valdastri, Pietro

    2015-01-01

    Capsule endoscopy (CE) has transformed from a research venture into a widely used clinical tool and the primary means for diagnosing small bowel pathology. These orally administered capsules traverse passively through the gastrointestinal tract via peristalsis and are used in the esophagus, stomach, small bowel, and colon. The primary focus of CE research in recent years has been enabling active CE manipulation and extension of the technology to therapeutic functionality; thus, widening the scope of the procedure. This review outlines clinical standards of the technology as well as recent advances in CE research. Clinical capsule applications are discussed with respect to each portion of the gastrointestinal tract. Promising research efforts are presented with an emphasis on enabling active capsule locomotion. The presented studies suggest, in particular, that the most viable solution for active capsule manipulation is actuation of a capsule via exterior permanent magnet held by a robot. Developing capsule procedures adhering to current healthcare standards, such as enabling a tool channel or irrigation in a therapeutic device, is a vital phase in the adaptation of CE in the clinical setting. PMID:26028956

  16. Efficiency of bowel preparation for capsule endoscopy examination: a meta-analysis.

    PubMed

    Niv, Yaron

    2008-03-07

    Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as "good" in 78% of the examinations performed with preparation and 49% performed without (P<0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum.

  17. NASPGHAN Capsule Endoscopy Clinical Report.

    PubMed

    Friedlander, Joel A; Liu, Quin Y; Sahn, Benjamin; Kooros, Koorosh; Walsh, Catharine M; Kramer, Robert E; Lightdale, Jenifer R; Khlevner, Julie; McOmber, Mark; Kurowski, Jacob; Giefer, Matthew J; Pall, Harpreet; Troendle, David M; Utterson, Elizabeth C; Brill, Herbert; Zacur, George M; Lirio, Richard A; Lerner, Diana G; Reynolds, Carrie; Gibbons, Troy E; Wilsey, Michael; Liacouras, Chris A; Fishman, Douglas S

    2017-03-01

    Wireless capsule endoscopy (CE) was introduced in 2000 as a less invasive method to visualize the distal small bowel in adults. Because this technology has advanced it has been adapted for use in pediatric gastroenterology. Several studies have described its clinical use, utility, and various training methods but pediatric literature regarding CE is limited. This clinical report developed by the Endoscopic and Procedures Committee of the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition outlines the current literature, and describes the recommended current role, use, training, and future areas of research for CE in pediatrics.

  18. Video capsule endoscopy: Perspectives of a revolutionary technique

    PubMed Central

    Bouchard, Simon; Ibrahim, Mostafa; Van Gossum, Andre

    2014-01-01

    Video capsule endoscopy (VCE) was launched in 2000 and has revolutionized direct endoscopic imaging of the gut. VCE is now a first-line procedure for exploring the small bowel in cases of obscure digestive bleeding and is also indicated in some patients with Crohn’s disease, celiac disease, and polyposis syndrome. A video capsule has also been designed for visualizing the esophagus in order to detect Barrett’s esophagus or esophageal varices. Different capsules are now available and differ with regard to dimensions, image acquisition rate, battery life, field of view, and possible optical enhancements. More recently, the use of VCE has been extended to exploring the colon. Within the last 5 years, tremendous developments have been made toward increasing the capabilities of the colon capsule. Although colon capsule cannot be proposed as a first-line colorectal cancer screening procedure, colon capsule may be used in patients with incomplete colonoscopy or in patients who are unwilling to undergo colonoscopy. In the near future, new technological developments will improve the diagnostic yield of VCE and broaden its therapeutic capabilities. PMID:25516644

  19. Pediatric capsule endoscopy: review of the small bowel and patency capsules.

    PubMed

    Cohen, Stanley A; Ephrath, Hagit; Lewis, Jeffery D; Klevens, Alan; Bergwerk, Ari; Liu, Steven; Patel, Dinesh; Reed-Knight, Bonney; Stallworth, Angela; Wakhisi, Tamara; Gold, Benjamin D

    2012-03-01

    Because capsule endoscopy (CE) avoids ionizing radiation, deep sedation, and general anesthesia, CE may be valuable in pediatrics. We report a single pediatric center's experience with the use and safety of CE. In a retrospective review of consecutive CE studies, 284 CE studies were performed in 277 patients with a mean age of 15 (±3.7) years during a 5-year period. The youngest to swallow the capsule was 4.6 years old. Twenty capsules were placed. Overall, 245 (86%) patients underwent CE for suspected (184, 65%) or confirmed (61, 21%) Crohn disease (CD); 27 (9.5%) anemia or gastrointestinal bleeding; 6 (2%) polyposis; and 4 (1.4%) celiac disease. Positive findings were observed in 205 (72%) of the studies, with 152 (54%) having small bowel findings. Of these, 72 (47%) were diagnostic. Gastric (95, 33%) and colonic (31, 11%) abnormalities were also identified. Five CE studies (1.8%) resulted in retention of the capsule in nonsurgical patients. A patency capsule before CE in 23 patients allowed 19 CE to proceed with only 1 retained capsule. In 65 (21%) patients, the video capsule did not enter the colon before the video's end. Of these, 36 (65%) had significant findings, including 27 (49%) documenting small bowel (SB) CD. CE is useful to diagnose SB disease in children. Even in a study population with a high prevalence of confirmed and suspected CD, the risk of retention remains small. The patency capsule may lessen that risk. CE may identify gastric or colonic disease even when SB lesions are not present.

  20. Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy

    PubMed Central

    Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young

    2011-01-01

    Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841

  1. Efficiency of bowel preparation for capsule endoscopy examination: A meta-analysis

    PubMed Central

    Niv, Yaron

    2008-01-01

    Good preparation before endoscopic procedures is essential for successful visualization. The small bowel is difficult to evaluate because of its length and complex configuration. A meta-analysis was conducted of studies comparing small bowel visualization by capsule endoscopy with and without preparation. Medical data bases were searched for all studies investigating the preparation for capsule endoscopy of the small bowel up to July 31, 2007. Studies that scored bowel cleanness and measured gastric and small bowel transit time and rate of cecum visualization were included. The primary endpoint was the quality of bowel visualization. The secondary endpoints were transit times and proportion of examinations that demonstrated the cecum, with and without preparation. Meta-analysis was performed with StatDirect Statistical software, version 2.6.1 (http://statsdirect.com). Eight studies met the inclusion criteria. Bowel visualization was scored as “good” in 78% of the examinations performed with preparation and 49% performed without (P < 0.0001). There were no significant differences in transit times or in the proportion of examinations that demonstrated the cecum with and without preparation. Capsule endoscopy preparation improves the quality of small bowel visualization, but has no effect on transit times, or demonstration of the cecum. PMID:18322940

  2. Virtual chromoendoscopy improves the diagnostic yield of small bowel capsule endoscopy in obscure gastrointestinal bleeding.

    PubMed

    Boal Carvalho, Pedro; Magalhães, Joana; Dias de Castro, Francisca; Gonçalves, Tiago Cúrdia; Rosa, Bruno; Moreira, Maria João; Cotter, José

    2016-02-01

    Small bowel capsule endoscopy represents the initial investigation for obscure gastrointestinal bleeding. Flexible spectral imaging colour enhancement (FICE) is a virtual chromoendoscopy technique designed to enhance mucosal lesions, available in different settings according to light wavelength-- FICE1, 2 and 3. To compare the diagnostic yield of FICE1 and white light during capsule endoscopy in patients with obscure gastrointestinal bleeding. Retrospective single-centre study including 60 consecutive patients referred for small bowel capsule endoscopy for obscure gastrointestinal bleeding. Endoscopies were independently reviewed in FICE1 and white light; findings were then reviewed by another researcher, establishing a gold standard. Diagnostic yield was defined as the presence of lesions with high bleeding potential (P2) angioectasias, ulcers or tumours. Diagnostic yield using FICE1 was significantly higher than white light (55% vs. 42%, p=0.021). A superior number of P2 lesions was detected with FICE1 (74 vs. 44, p=0.003), particularly angioectasias (54 vs. 26, p=0.002), but not ulcers or tumours. FICE1 was significantly superior to white light, resulting in a 13% improvement in diagnostic yield, and potentially bleeding lesions particularly angioectasias were more often observed. Our results support the use of FICE1 while reviewing small bowel capsule endoscopy for obscure gastrointestinal bleeding. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. A robust real-time abnormal region detection framework from capsule endoscopy images

    NASA Astrophysics Data System (ADS)

    Cheng, Yanfen; Liu, Xu; Li, Huiping

    2009-02-01

    In this paper we present a novel method to detect abnormal regions from capsule endoscopy images. Wireless Capsule Endoscopy (WCE) is a recent technology where a capsule with an embedded camera is swallowed by the patient to visualize the gastrointestinal tract. One challenge is one procedure of diagnosis will send out over 50,000 images, making physicians' reviewing process expensive. Physicians' reviewing process involves in identifying images containing abnormal regions (tumor, bleeding, etc) from this large number of image sequence. In this paper we construct a novel framework for robust and real-time abnormal region detection from large amount of capsule endoscopy images. The detected potential abnormal regions can be labeled out automatically to let physicians review further, therefore, reduce the overall reviewing process. In this paper we construct an abnormal region detection framework with the following advantages: 1) Trainable. Users can define and label any type of abnormal region they want to find; The abnormal regions, such as tumor, bleeding, etc., can be pre-defined and labeled using the graphical user interface tool we provided. 2) Efficient. Due to the large number of image data, the detection speed is very important. Our system can detect very efficiently at different scales due to the integral image features we used; 3) Robust. After feature selection we use a cascade of classifiers to further enforce the detection accuracy.

  4. Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding.

    PubMed

    Redondo-Cerezo, Eduardo; Sánchez-Capilla, Antonio Damián; De La Torre-Rubio, Paloma; De Teresa, Javier

    2014-11-14

    Wireless capsule endoscopy (CE) is a technology developed for the endoscopic exploration of the small bowel. The first capsule model was approved by the Food and Drug Administration in 2001, and its first and essential indication was occult gastrointestinal (GI) bleeding. Over subsequent years, this technology has been refined to provide superior resolution, increased battery life, and capabilities to view different parts of the GI tract. Indeed, cases for which CE proved useful have increased significantly over the last few years, with new indications for the small bowel and technical improvements that have expanded its use to other parts of the GI tract, including the esophagus and colon. The main challenges in the development of CE are new devices with the ability to provide therapy, air inflation for a better vision of the small bowel, biopsy sampling systems attached to the capsule and the possibility to guide and move the capsule with an external motion control. In this article we review the current and new indications of CE, and the evolving technological changes shaping this technology, which has a promising potential in the coming future of gastroenterology.

  5. Retention of the capsule endoscope: a single-center experience of 1000 capsule endoscopy procedures.

    PubMed

    Li, Feng; Gurudu, Suryakanth R; De Petris, Giovanni; Sharma, Virender K; Shiff, Arthur D; Heigh, Russell I; Fleischer, David E; Post, Janice; Erickson, Paula; Leighton, Jonathan A

    2008-07-01

    Retention of the video capsule is the most significant complication associated with capsule endoscopy (CE). There are limited data on incidence, risk factors, and outcomes of capsule retention. We aimed to determine the incidence of capsule retention and to investigate the causes and clinical outcomes of capsule retention. Single tertiary referral medical center. All patients who underwent CE for suspected small bowel disease from June 2002 to March 2006. Retrospective case series. Capsule retention occurred in 1.4% of our patients (14/1000). Eleven patients failed to pass the capsule because of nonsteroidal anti-inflammatory drug (NSAID) enteropathy (diaphragm disease). One patient had capsule retention from an obstructing carcinoid tumor. Metastatic ovarian cancer with invasion of the ileum was the cause of retention in another patient. One patient who did not have surgical removal of the capsule because of loss of follow-up had retention caused by a small-bowel tumor suspicious for carcinoid tumor on CT enterography. All patients remained "asymptomatic" from the retained capsules. Thirteen patients underwent elective partial small-bowel resection and capsule removal. No deaths were associated with these surgeries. Eleven patients recovered promptly, whereas 2 patients had mild postoperative ileus. Retrospective study. Retention of the capsule endoscope appears to be infrequent. The most common cause is diaphragm disease resulting from NSAIDs in this study population. In most cases, capsule retention is asymptomatic, and it usually leads to surgical removal, which appears safe and also identifies and treats the underlying small-bowel condition.

  6. Capsule endoscopy of the future: What’s on the horizon?

    PubMed Central

    Slawinski, Piotr R; Obstein, Keith L; Valdastri, Pietro

    2015-01-01

    Capsule endoscopes have evolved from passively moving diagnostic devices to actively moving systems with potential therapeutic capability. In this review, we will discuss the state of the art, define the current shortcomings of capsule endoscopy, and address research areas that aim to overcome said shortcomings. Developments in capsule mobility schemes are emphasized in this text, with magnetic actuation being the most promising endeavor. Research groups are working to integrate sensor data and fuse it with robotic control to outperform today’s standard invasive procedures, but in a less intrusive manner. With recent advances in areas such as mobility, drug delivery, and therapeutics, we foresee a translation of interventional capsule technology from the bench-top to the clinical setting within the next 10 years. PMID:26457013

  7. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    PubMed Central

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy. PMID:20811612

  8. Historical analysis of experience with small bowel capsule endoscopy in a spanish tertiary hospital.

    PubMed

    Egea Valenzuela, Juan; Carrilero Zaragoza, Gabriel; Iglesias Jorquera, Elena; Tomás Pujante, Paula; Alberca de Las Parras, Fernando; Carballo Álvarez, Fernando

    2017-02-01

    Capsule endoscopy was approved by the FDA in 2001. Gastrointestinal bleeding and inflammatory bowel disease are the main indications. It has been available in our hospital since 2004. We retrospectively analysed data from patients who underwent small bowel capsule endoscopy in our hospital from October 2004 to April 2015. Indications were divided into: Obscure gastrointestinal bleeding (occult and overt), inflammatory bowel disease, and other indications. Findings were divided into: Vascular lesions, inflammatory lesions, other lesions, normal studies, and inconclusive studies. A total of 1027 out of 1291 small bowel studies were included. Mean patient age was 56.45 years; 471 were men and 556 women. The most common lesion observed was angiectasia, as an isolated finding or associated with other lesions. Findings were significant in up to 80% of studies when the indication was gastrointestinal bleeding, but in only 50% of studies in inflammatory bowel disease. Diagnostic yield was low in the group «other indications». No major complications were reported. Small bowel capsule endoscopy has high diagnostic yield in patients with gastrointestinal bleeding, but yield is lower in patients with inflammatory bowel disease. Our experience shows that capsule endoscopy is a safe and useful tool for the diagnosis of small bowel disease. The diagnostic yield of the technique in inflammatory bowel disease must be improved. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  9. Clinical usefulness of novel tag-less Agile patency capsule prior to capsule endoscopy for patients with suspected small bowel stenosis.

    PubMed

    Nakamura, Masanao; Hirooka, Yoshiki; Yamamura, Takeshi; Miyahara, Ryoji; Watanabe, Osamu; Ando, Takafumi; Ohmiya, Naoki; Goto, Hidemi

    2015-01-01

    The Agile patency capsule (PC; Given Imaging Ltd, Yoqneam, Israel) is used as a dummy prior to capsule endoscopy (CE) to avoid retention of the CE capsule. However, impaction of the PC's inner radio frequency identification (RFID) tag in a stricture could cause small-bowel ileus. Recently, the RFID tag-less PC was introduced into clinical practice. Herein, we aimed to retrospectively evaluate the usefulness of the tag-less PC. Of 154 patients who were scheduled to undergo CE, 100 consecutive patients (65%) who underwent PC evaluation were enrolled in the present study. Primary study end point was the retention rate of the CE capsule after successful passage of the PC. Secondary end point was analysis of the significant factors affecting the passage of the PC. In total, 87 patients (87%) had bowel patency confirmed by PC evaluation. There was no capsule retention in any of these 87 patients during CE. Abnormal findings were obtained from 60 CE, and 41 patients received new or modified treatment. Multivariate analysis of factors related to the confirmation of patency demonstrated that stenosis on imaging was the most influential factor (P = 0.002, odds ratio 16.387). The results confirmed that passage of the PC depends on stenosis on imaging. Use of the tag-less PC confirmed gastrointestinal tract patency for most of the patients who did not have stenosis on imaging and allowed estimation of the patency for patients who did have stenosis on imaging. © 2014 The Authors. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  10. Multilevel wireless capsule endoscopy video segmentation

    NASA Astrophysics Data System (ADS)

    Hwang, Sae; Celebi, M. Emre

    2010-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. WCE transmits more than 50,000 video frames per examination and the visual inspection of the resulting video is a highly time-consuming task even for the experienced gastroenterologist. Typically, a medical clinician spends one or two hours to analyze a WCE video. To reduce the assessment time, it is critical to develop a technique to automatically discriminate digestive organs and shots each of which consists of the same or similar shots. In this paper a multi-level WCE video segmentation methodology is presented to reduce the examination time.

  11. A discrete-time localization method for capsule endoscopy based on on-board magnetic sensing

    NASA Astrophysics Data System (ADS)

    Salerno, Marco; Ciuti, Gastone; Lucarini, Gioia; Rizzo, Rocco; Valdastri, Pietro; Menciassi, Arianna; Landi, Alberto; Dario, Paolo

    2012-01-01

    Recent achievements in active capsule endoscopy have allowed controlled inspection of the bowel by magnetic guidance. Capsule localization represents an important enabling technology for such kinds of platforms. In this paper, the authors present a localization method, applied as first step in time-discrete capsule position detection, that is useful for establishing a magnetic link at the beginning of an endoscopic procedure or for re-linking the capsule in the case of loss due to locomotion. The novelty of this approach consists in using magnetic sensors on board the capsule whose output is combined with pre-calculated magnetic field analytical model solutions. A magnetic field triangulation algorithm is used for obtaining the position of the capsule inside the gastrointestinal tract. Experimental validation has demonstrated that the proposed procedure is stable, accurate and has a wide localization range in a volume of about 18 × 103 cm3. Position errors of 14 mm along the X direction, 11 mm along the Y direction and 19 mm along the Z direction were obtained in less than 27 s of elaboration time. The proposed approach, being compatible with magnetic fields used for locomotion, can be easily extended to other platforms for active capsule endoscopy.

  12. Robotics in endoscopy.

    PubMed

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  13. Quantitative analysis of patients with celiac disease by video capsule endoscopy: A deep learning method.

    PubMed

    Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing

    2017-06-01

    Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Automatic blood detection in capsule endoscopy video

    NASA Astrophysics Data System (ADS)

    Novozámský, Adam; Flusser, Jan; Tachecí, Ilja; Sulík, Lukáš; Bureš, Jan; Krejcar, Ondřej

    2016-12-01

    We propose two automatic methods for detecting bleeding in wireless capsule endoscopy videos of the small intestine. The first one uses solely the color information, whereas the second one incorporates the assumptions about the blood spot shape and size. The original idea is namely the definition of a new color space that provides good separability of blood pixels and intestinal wall. Both methods can be applied either individually or their results can be fused together for the final decision. We evaluate their individual performance and various fusion rules on real data, manually annotated by an endoscopist.

  15. Capsule endoscopy in pediatrics: a 10-years journey.

    PubMed

    Oliva, Salvatore; Cohen, Stanley A; Di Nardo, Giovanni; Gualdi, Gianfranco; Cucchiara, Salvatore; Casciani, Emanuele

    2014-11-28

    Video capsule endoscopy (CE) for evaluation the esophagus (ECE), small bowel (SBCE) and the colon (CCE) is particularly useful in pediatrics, because this imaging modality does not require ionizing radiation, deep sedation or general anesthesia. The risk of capsule retention appears to be dependent on indication rather than age and parallels the adult experience by indication, making SBCE a relatively safe procedure with a significant diagnostic yield. The newest indication, assessment of mucosal change, greatly enhances and expands its potential benefit. The diagnostic role of CE extends beyond the SB. The use of ECE also may enhance our knowledge of esophageal disease and assist patient care. Colon CCE is a novel minimally invasive and painless endoscopic technique allowing exploration of the colon without need for sedation, rectal intubation and gas insufflation. The limited data on ECE and CCE in pediatrics does not yet allow the same conclusions regarding efficacy; however, both appear to provide safe methods to assess and monitor mucosal change in their respective areas with little discomfort. Moreover, although experience has been limited, the patency capsule may help lessen the potential of capsule retention; and newly researched protocols for bowel cleaning may further enhance CE's diagnostic yield. However, further research is needed to optimize the use of the various CE procedures in pediatric populations.

  16. Blood detection in wireless capsule endoscopy using expectation maximization clustering

    NASA Astrophysics Data System (ADS)

    Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.

    2006-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.

  17. Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Rukundo, Olivier

    2018-04-01

    This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.

  18. In-to-out body path loss for wireless radio frequency capsule endoscopy in a human body.

    PubMed

    Vermeeren, G; Tanghe, E; Thielens, A; Martens, L; Joseph, W

    2016-08-01

    Physical-layer characterization is important for design of in-to-out body communication for wireless body area networks (WBANs). This paper numerically investigates the path loss of an in-to-out body radio frequency (RF) wireless link between an endoscopy capsule and a receiver outside the body using a 3D electromagnetic solver. A spiral antenna in the endoscopy capsule is tuned to operate in the Medical Implant Communication Service (MICS) band at 402 MHz, accounting for the properties of the human body. The influence of misalignment, rotation of the capsule, and human body model are investigated. Semi-empirical path loss models for various homogeneous tissues and 3D realistic human body models are provided for manufacturers to evaluate the performance of in-to-out-body WBAN systems.

  19. Feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy.

    PubMed

    Zhou, Jieqiong; Tang, Xiaowei; Wang, Jing; Chen, Zhenyu; Wang, Xinying; Jiang, Bo

    2017-08-01

    Bowel preparation regimens for colon capsule endoscopy are not yet standardized since they are not well optimized. The aim of the present study was to evaluate the feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy. A total of 31 patients were prospectively enrolled. In the novel regimen, on the day prior to examination, a low-fiber diet was permitted, 5 mg mosapride citrate was administered twice (1 h prior to lunch and supper) and 1 l polyethylene glycol was administered in the evening. On the day of the examination, an additional 1 l polyethylene glycol, 5 mg mosapride citrate and 200 mg simethicone were administered before capsule ingestion. Polyethylene glycol booster (0.5 l) was administered twice, at 1 and 4 h following capsule ingestion. Colon cleansing levels, ileocecal valve transit time and completion rate were evaluated. A total of 29 patients were included in the final analysis, 90% of whom achieved adequate preparation of the overall colon. Ileocecal valve transit time was 2.35±0.82 h and completion rate was 79.3%. The results revealed that the novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy was feasible, with adequate colon cleansing and completion rates, and has the potential to be used as an alternative regimen.

  20. Retained Capsule Endoscope.

    PubMed

    Aihole, Jayalaxmi S; Vishnumurthy, G S; Babu, M Narendra

    2016-11-15

    Capsule endoscopy was invented to visualize the entire small intestine in a non- invasive manner in adults. 1 y, 9 mo-old boy presented with generalized edema for last 3 months. His routine investigations, including the upper gastrointestinal endoscopy, colonoscopy, and contrast enhanced computed tomography scan (CECT) were normal. In view of clinical suspicion of protein losing enteropathy, we planned capsule endoscopy. The capsule was not passed even after 3 weeks. Laparoscopy revealed impacted capsule in a dilated intestinal loop proximal to an ileal stricuture. Capsule endoscopy should be used judiciously in children.

  1. Application of wireless power transmission systems in wireless capsule endoscopy: an overview.

    PubMed

    Basar, Md Rubel; Ahmad, Mohd Yazed; Cho, Jongman; Ibrahim, Fatimah

    2014-06-19

    Wireless capsule endoscopy (WCE) is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB). To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE) units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT) system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.

  2. Small bowel involvement documented by capsule endoscopy in Churg-Strauss syndrome

    PubMed Central

    Beye, Birane; Lesur, Gilles; Claude, Pierre; Martzolf, Lionel; Kieffer, Pierre; Sondag, Daniel

    2015-01-01

    Churg-Strauss syndrome is a small and medium vessel vasculitis and is also known as allergic granulomatous angiitis. Gastrointestinal involvement is common in patients with Churg-Strauss syndrome (20-50%). The most common symptoms are abdominal pain, diarrhoea and occasionally gastrointestinal bleeding and perforation. We present a case of Churg-Strauss syndrome with small bowel lesions documented by video capsule endoscopy. PMID:26664542

  3. Small bowel involvement documented by capsule endoscopy in Churg-Strauss syndrome.

    PubMed

    Beye, Birane; Lesur, Gilles; Claude, Pierre; Martzolf, Lionel; Kieffer, Pierre; Sondag, Daniel

    2015-01-01

    Churg-Strauss syndrome is a small and medium vessel vasculitis and is also known as allergic granulomatous angiitis. Gastrointestinal involvement is common in patients with Churg-Strauss syndrome (20-50%). The most common symptoms are abdominal pain, diarrhoea and occasionally gastrointestinal bleeding and perforation. We present a case of Churg-Strauss syndrome with small bowel lesions documented by video capsule endoscopy.

  4. On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.

    2011-03-01

    Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.

  5. Small-bowel capsule endoscopy: A ten-point contemporary review

    PubMed Central

    Koulaouzidis, Anastasios; Rondonotti, Emanuele; Karargyris, Alexandros

    2013-01-01

    The introduction of capsule endoscopy (CE) in clinical practice increased the interest for the study of the small-bowel. Consequently, in about 10 years, an impressive quantity of literature on indications, diagnostic yield (DY), safety profile and technical evolution of CE has been published as well as several reviews. At present time, there are 5 small-bowel capsule enteroscopy (SBCE) models in the worldwide market. Head-to-head trials have showed in the great majority of studies comparable results in terms of DY, image quality and completion rate. CE meta-analyses formed the basis of national/international guidelines; these guidelines place CE in a prime position for the diagnostic work-up of patients with obscure gastrointestinal bleeding, known and/or suspected Crohn’s disease and possible small-bowel neoplasia. A 2-L polyethylene glycol-based purge, administered the day before the procedure, is the most widely practiced preparation regimen. Whether this regimen can be further improved (i.e., by further decreasing its volume, changing the timing of administration, coupling it with prokinetics and/or other factors) or if it can really affect the DY, is still under discussion. Faecal calprotectin has been used in SBCE studies in two settings: in patients taking non-steroidal anti-inflammatory drugs, to evaluate the type and extent of mucosal damage and, more importantly from a clinical point of view, in patients with known or suspected Crohn’s disease for assessment of inflammation activity. Although there is still a lot of debate around the exact reasons of SBCE poor performance in various small-bowel segments, it is worth to remember that the capsule progress is non-steerable, hence more rapid in the proximal than in lower segments of the small-bowel. Capsule aspiration, a relatively unexpected complication, has been reported with increasing frequency. This is probably related with the increase in the mean age of patients undergoing CE. CE video review is

  6. Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy.

    PubMed

    Wang, Xingying; Seetohul, Vipin; Chen, Ruimin; Zhang, Zhiqiang; Qian, Ming; Shi, Zhehao; Yang, Ge; Mu, Peitian; Wang, Congzhi; Huang, Zhihong; Zhou, Qifa; Zheng, Hairong; Cochran, Sandy; Qiu, Weibao

    2017-09-01

    Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementary solution as it is capable of acquiring transmural information from the tissue wall. This paper presents a mechanical scanning device incorporating a high-frequency transducer specifically as a proof of concept for US capsule endoscopy (USCE), providing information that may usefully assist future research. A rotary solenoid-coil-based motor was employed to rotate the US transducer with sectional electronic control. A set of gears was used to convert the sectional rotation to circular rotation. A single-element focused US transducer with 39-MHz center frequency was used for high-resolution US imaging, connected to an imaging platform for pulse generation and image processing. Key parameters of US imaging for USCE applications were evaluated. Wire phantom imaging and tissue phantom imaging have been conducted to evaluate the performance of the proposed method. A porcine small intestine specimen was also used for imaging evaluation in vitro. Test results demonstrate that the proposed device and rotation mechanism are able to offer good image resolution ( [Formula: see text]) of the lumen wall, and they, therefore, offer a viable basis for the fabrication of a USCE device.

  7. Capsule endoscopy in Crohn’s disease: Are we seeing any better?

    PubMed Central

    Hudesman, David; Mazurek, Jonathan; Swaminath, Arun

    2014-01-01

    Crohn’s disease (CD) is a complex, immune-mediated disorder that often requires a multi-modality approach for optimal diagnosis and management. While traditional methods include ileocolonoscopy and radiologic modalities, increasingly, capsule endoscopy (CE) has been incorporated into the algorithm for both the diagnosis and monitoring of CD. Multiple studies have examined the utility of this emerging technology in the management of CD, and have compared it to other available modalities. CE offers a noninvasive approach to evaluate areas of the small bowel that are difficult to reach with traditional endoscopy. Furthermore, CE maybe favored in specific sub segments of patients with inflammatory bowel disease (IBD), such as those with IBD unclassified (IBD-U), pediatric patients and patients with CD who have previously undergone surgery. PMID:25278698

  8. Acoustic Sensing and Ultrasonic Drug Delivery in Multimodal Theranostic Capsule Endoscopy

    PubMed Central

    Stewart, Fraser R.; Qiu, Yongqiang; Newton, Ian P.; Cox, Benjamin F.; Al-Rawhani, Mohammed A.; Beeley, James; Liu, Yangminghao; Huang, Zhihong; Cumming, David R. S.; Näthke, Inke

    2017-01-01

    Video capsule endoscopy (VCE) is now a clinically accepted diagnostic modality in which miniaturized technology, an on-board power supply and wireless telemetry stand as technological foundations for other capsule endoscopy (CE) devices. However, VCE does not provide therapeutic functionality, and research towards therapeutic CE (TCE) has been limited. In this paper, a route towards viable TCE is proposed, based on multiple CE devices including important acoustic sensing and drug delivery components. In this approach, an initial multimodal diagnostic device with high-frequency quantitative microultrasound that complements video imaging allows surface and subsurface visualization and computer-assisted diagnosis. Using focused ultrasound (US) to mark sites of pathology with exogenous fluorescent agents permits follow-up with another device to provide therapy. This is based on an US-mediated targeted drug delivery system with fluorescence imaging guidance. An additional device may then be utilized for treatment verification and monitoring, exploiting the minimally invasive nature of CE. While such a theranostic patient pathway for gastrointestinal treatment is presently incomplete, the description in this paper of previous research and work under way to realize further components for the proposed pathway suggests it is feasible and provides a framework around which to structure further work. PMID:28671642

  9. Rapid Access Real-Time device and Rapid Access software: new tools in the armamentarium of capsule endoscopy.

    PubMed

    Spada, Cristiano; Riccioni, Maria Elena; Costamagna, Guido

    2007-07-01

    Small bowel capsule endoscopy represents a significant advance in the investigation of the small bowel, allowing direct visualization of this section of the gastrointestinal system. More recently, new video capsules have been released, specifically designed to investigate the esophagus and the colon. In June 2006, Given Imaging Ltd received marketing clearance from the US FDA for the Rapid Access Real-Time (RT) and Rapid Access software. The Rapid Access RT is a handheld device that enables real-time viewing during capsule endoscopy procedures. To date, the clinical benefits of this device are unknown as studies on the Rapid Access RT system have not yet been published. However, it appears that the Rapid Access RT system may reduce the examination and reading time, and may impact significantly in cases where it is important to know the precise localization of the capsule (during PillCam ESO ingestion procedures, PillCam Colon examinations or when delayed gastric transit is suspected) or in case of severe gastrointestinal bleeding (when a therapeutic procedure is required urgently).

  10. Endoscopic Scores for Evaluation of Crohn's Disease Activity at Small Bowel Capsule Endoscopy: General Principles and Current Applications.

    PubMed

    Rosa, Bruno; Pinho, Rolando; de Ferro, Susana Mão; Almeida, Nuno; Cotter, José; Saraiva, Miguel Mascarenhas

    2016-01-01

    The small bowel is affected in the vast majority of patients with Crohn's Disease (CD). Small bowel capsule endoscopy (SBCE) has a very high sensitivity for the detection of CD-related pathology, including early mucosal lesions and/or those located in the proximal segments of the small bowel, which is a major advantage when compared with other small bowel imaging modalities. The recent guidelines of European Society of Gastrointestinal Endoscopy (ESGE) and European Crohn's and Colitis Organisation (ECCO) advocate the use of validated endoscopic scoring indices for the classification of inflammatory activity in patients with CD undergoing SBCE, such as the Lewis Score or the Capsule Endoscopy Crohn's Disease Activity Index (CECDAI). These scores aim to standardize the description of lesions and capsule endoscopy reports, contributing to increase inter-observer agreement and enabling a stratification of the severity of the disease. On behalf of the Grupo de Estudos Português do Intestino Delgado (GEPID) - Portuguese Small Bowel Study Group, we aimed to summarize the general principles and clinical applications of current endoscopic scoring systems for SBCE in the setting of CD, covering the topic of suspected CD as well as the evaluation of disease extent (with potential prognostic and therapeutic impact), evaluation of mucosal healing in response to treatment and evaluation of post-surgical recurrence in patients with previously established diagnosis of CD.

  11. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy.

    PubMed

    Herrerias, Juan M; Leighton, Jonathan A; Costamagna, Guido; Infantolino, Anthony; Eliakim, Rami; Fischer, Doron; Rubin, David T; Manten, Howard D; Scapa, Eitan; Morgan, Douglas R; Bergwerk, Ari J; Koslowsky, Binyamin; Adler, Samuel N

    2008-05-01

    Capsule endoscopy (CE) of the small bowel has become a standard diagnostic tool, but there have been concerns regarding the risk of capsule retention in certain high-risk groups. The Agile patency system, an ingestible and dissolvable capsule with an external scanner, was developed to allow physicians to perform CE with greater confidence that the capsule will be safely excreted in patients at risk for capsule retention. Our purpose was to assess the ability of the device to help physicians identify which patients with known strictures may safely undergo CE. Patients with known strictures ingested the new patency capsule and underwent periodic scanning until it was excreted. The intestinal tract was considered to be sufficiently patent if the capsule was excreted intact or if the capsule was not detected by the scanner at 30 hours after ingestion. If patency was established, then standard CE was performed. International multicenter study. A total of 106 patients with known strictures. Agile patency system. Performance and safety of Agile patency system. A total of 106 patients ingested the patency capsule. Fifty-nine (56%) excreted it intact and subsequently underwent CE. There were no cases of capsule retention. Significant findings on CE were found in 24 (41%). There were 3 severe adverse events. These results suggest that the Agile patency system is a useful tool for physicians to use before CE in patients with strictures to avoid retention. This group of patients may have a high yield of clinically significant findings at CE. This capsule may determine whether patients who have a contraindication to CE may safely undergo CE and obtain useful diagnostic information.

  12. A modular and programmable development platform for capsule endoscopy system.

    PubMed

    Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A

    2014-06-01

    The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.

  13. Multicenter prospective evaluation of the express view reading mode for small-bowel capsule endoscopy studies.

    PubMed

    Saurin, Jean-Christophe; Jacob, Philippe; Heyries, Laurent; Pesanti, Christian; Cholet, Franck; Fassler, Isaac; Boulant, James; Bramli, Slim; De Leusse, Antoin; Rahmi, Gabriel

    2018-05-01

     Reducing the reading time of capsule endoscopy films is of high priority for gastroenterologists. We report a prospective multicenter evaluation of an "express view" reading mode (Intromedic capsule system).  Eighty-three patients with obscure gastrointestinal bleeding were prospectively included in 10 centers. All patients underwent small-bowel capsule endoscopy (Intromedic, Seoul, Republic of Korea). Films were read in standard mode, then a second reading was performed in express view mode at a second center. For each lesion, the precise location, nature, and relevance were collected. A consensus reading and review were done by three experts, and considered to be the gold standard.  The mean reading time of capsule films was 39.7 minutes (11 - 180 minutes) and 19.7 minutes (4 - 40 minutes) by standard and express view mode, respectively ( P  < 1 × 10  - 4 ). The consensus review identified a significant lesion in 44/83 patients (53.0 %). Standard reading and express view reading had a 93.3 % and 82.2 % sensitivity, respectively (NS). Consensus review identified 70 significant images from which standard reading and express view reading detected 58 (82.9 %) and 55 (78.6 %), respectively. The informatics algorithm detected 66/70 images (94.3 %) thus missing four small-bowel angiodysplasia.  The express view algorithm allows an important shortening of Intromedic capsule film reading time with a high sensitivity.

  14. Optimal Bowel Preparation for Video Capsule Endoscopy

    PubMed Central

    Song, Hyun Joo; Moon, Jeong Seop; Shim, Ki-Nam

    2016-01-01

    During video capsule endoscopy (VCE), several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies, consensus, and guidelines regarding different kinds of bowel cleansing agents in bowel preparation for small bowel VCE. Presently, polyethylene glycol- (PEG-) based regimens are given primary recommendation. Sodium picosulphate-based regimens are secondarily recommended, as their cleansing efficacy is less than that of PEG-based regimens. Sodium phosphate as well as complementary simethicone and prokinetics use are considered. In this paper, we reviewed previous studies regarding bowel preparation for small bowel VCE and suggested optimal bowel preparation of VCE. PMID:26880894

  15. Safety and utility of capsule endoscopy for infants and young children

    PubMed Central

    Oikawa-Kawamoto, Manari; Sogo, Tsuyoshi; Yamaguchi, Takeshi; Tsunoda, Tomoyuki; Kondo, Takeo; Komatsu, Haruki; Inui, Ayano; Fujisawa, Tomoo

    2013-01-01

    AIM: To assess the safety and utility of capsule endoscopy (CE) for children who are unable to swallow the capsule endoscope. METHODS: The medical records of all of the children who underwent CE between 2010 and 2012 were retrospectively reviewed. The patients were divided into 2 groups: group A included patients who were unable to swallow the capsule endoscope, and group B included patients who were able to swallow it. For the patients who were unable to swallow the capsule endoscope, it was placed in the duodenum endoscopically. The small bowel transit time, endoscopic diagnosis and complications of the 2 groups were compared. RESULTS: During the study period, 28 CE procedures were performed in 26 patients. Group A included 11 patients with a median age of 2 years (range 10 mo-9 years), and group B included 15 patients with a median age of 12 years (range 8 years-16 years). The lightest child in the study weighed 7.9 kg. The detection rates did not differ between the 2 groups. The median small bowel transit time was 401 min (range 264-734 min) in group A and 227 min (range 56-512 min) in group B (P = 0.0078). No serious complications, including capsule retention, occurred. No significant mucosal trauma occurred in the pharynx, esophagus, stomach or duodenum when the capsule was introduced using an endoscope. CONCLUSION: CE is a safe and useful procedure for infants and young children who are unable to swallow the capsule endoscope. PMID:24363526

  16. Safety and utility of capsule endoscopy for infants and young children.

    PubMed

    Oikawa-Kawamoto, Manari; Sogo, Tsuyoshi; Yamaguchi, Takeshi; Tsunoda, Tomoyuki; Kondo, Takeo; Komatsu, Haruki; Inui, Ayano; Fujisawa, Tomoo

    2013-12-07

    To assess the safety and utility of capsule endoscopy (CE) for children who are unable to swallow the capsule endoscope. The medical records of all of the children who underwent CE between 2010 and 2012 were retrospectively reviewed. The patients were divided into 2 groups: group A included patients who were unable to swallow the capsule endoscope, and group B included patients who were able to swallow it. For the patients who were unable to swallow the capsule endoscope, it was placed in the duodenum endoscopically. The small bowel transit time, endoscopic diagnosis and complications of the 2 groups were compared. During the study period, 28 CE procedures were performed in 26 patients. Group A included 11 patients with a median age of 2 years (range 10 mo-9 years), and group B included 15 patients with a median age of 12 years (range 8 years-16 years). The lightest child in the study weighed 7.9 kg. The detection rates did not differ between the 2 groups. The median small bowel transit time was 401 min (range 264-734 min) in group A and 227 min (range 56-512 min) in group B (P = 0.0078). No serious complications, including capsule retention, occurred. No significant mucosal trauma occurred in the pharynx, esophagus, stomach or duodenum when the capsule was introduced using an endoscope. CE is a safe and useful procedure for infants and young children who are unable to swallow the capsule endoscope. © 2013 Baishideng Publishing Group Co., Limited. All rights reserved.

  17. Design of a video capsule endoscopy system with low-power ASIC for monitoring gastrointestinal tract.

    PubMed

    Liu, Gang; Yan, Guozheng; Zhu, Bingquan; Lu, Li

    2016-11-01

    In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.

  18. Comparison of the diagnostic yield and outcomes between standard 8 h capsule endoscopy and the new 12 h capsule endoscopy for investigating small bowel pathology.

    PubMed

    Rahman, Merajur; Akerman, Stuart; DeVito, Bethany; Miller, Larry; Akerman, Meredith; Sultan, Keith

    2015-05-14

    To evaluate the completion rate and diagnostic yield of the PillCam SB2-ex in comparison to the PillCam SB2. Two hundred cases using the 8-h PillCam SB2 were retrospectively compared to 200 cases using the 12 h PillCam SB2-ex at a tertiary academic center. Endoscopically placed capsules were excluded from the study. Demographic information, indications for capsule endoscopy, capsule type, study length, completion of exam, clinically significant findings, timestamp of most distant finding, and significant findings beyond 8 h were recorded. The 8 and 12 h capsule groups were well matched respectively for both age (70.90 ± 14.19 vs 71.93 ± 13.80, P = 0.46) and gender (45.5% vs 48% male, P = 0.69). The most common indications for the procedure in both groups were anemia and obscure gastrointestinal bleeding. PillCam SB2-ex had a significantly higher completion rate than PillCam SB2 (88% vs 79.5%, P = 0.03). Overall, the diagnostic yield was greater for the 8 h capsule (48.5% for SB2 vs 35% for SB2-ex, P = 0.01). In 4/70 (5.7%) of abnormal SB2-ex exams the clinically significant finding was noted in the small bowel beyond the 8 h mark. In our study, we found the PillCam SB2-ex to have a significantly increased completion rate, though without any improvement in diagnostic yield compared to the PillCam SB2.

  19. A primary intestinal lymphangiectasia patient diagnosed by capsule endoscopy and confirmed at surgery: a case report.

    PubMed

    Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao

    2007-04-21

    Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination.

  20. Small-bowel capsule endoscopy in patients with suspected Crohn's disease-diagnostic value and complications.

    PubMed

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  1. New optical method for enhanced detection of colon cancer by capsule endoscopy

    NASA Astrophysics Data System (ADS)

    AnkriEqually Contributed, Rinat; Peretz, Dolev; Motiei, Menachem; Sella-Tavor, Osnat; Popovtzer, Rachela

    2013-09-01

    PillCam®COLON capsule endoscopy (CE), a non-invasive diagnostic tool of the digestive tract, has dramatically changed the diagnostic approach and has become an attractive alternative to the conventional colonoscopy for early detection of colorectal cancer. However, despite the significant progress and non-invasive detection capability, studies have shown that its sensitivity and specificity is lower than that of conventional colonoscopy. This work presents a new optical detection method, specifically tailored to colon cancer detection and based on the well-known optical properties of immune-conjugated gold nanorods (GNRs). We show, on a colon cancer model implanted in a chick chorioallantoic membrane (CAM), that this detection method enables conclusive differentiation between cancerous and normal tissues, where neither the distance between the light source and the intestinal wall, nor the background signal, affects the monitored signal. This optical method, which can easily be integrated in CE, is expected to reduce false positive and false negative results and improve identification of tumors and micro metastases.

  2. A modified anomaly detection method for capsule endoscopy images using non-linear color conversion and Higher-order Local Auto-Correlation (HLAC).

    PubMed

    Hu, Erzhong; Nosato, Hirokazu; Sakanashi, Hidenori; Murakawa, Masahiro

    2013-01-01

    Capsule endoscopy is a patient-friendly endoscopy broadly utilized in gastrointestinal examination. However, the efficacy of diagnosis is restricted by the large quantity of images. This paper presents a modified anomaly detection method, by which both known and unknown anomalies in capsule endoscopy images of small intestine are expected to be detected. To achieve this goal, this paper introduces feature extraction using a non-linear color conversion and Higher-order Local Auto Correlation (HLAC) Features, and makes use of image partition and subspace method for anomaly detection. Experiments are implemented among several major anomalies with combinations of proposed techniques. As the result, the proposed method achieved 91.7% and 100% detection accuracy for swelling and bleeding respectively, so that the effectiveness of proposed method is demonstrated.

  3. Software for enhanced video capsule endoscopy: challenges for essential progress.

    PubMed

    Iakovidis, Dimitris K; Koulaouzidis, Anastasios

    2015-03-01

    Video capsule endoscopy (VCE) has revolutionized the diagnostic work-up in the field of small bowel diseases. Furthermore, VCE has the potential to become the leading screening technique for the entire gastrointestinal tract. Computational methods that can be implemented in software can enhance the diagnostic yield of VCE both in terms of efficiency and diagnostic accuracy. Since the appearance of the first capsule endoscope in clinical practice in 2001, information technology (IT) research groups have proposed a variety of such methods, including algorithms for detecting haemorrhage and lesions, reducing the reviewing time, localizing the capsule or lesion, assessing intestinal motility, enhancing the video quality and managing the data. Even though research is prolific (as measured by publication activity), the progress made during the past 5 years can only be considered as marginal with respect to clinically significant outcomes. One thing is clear-parallel pathways of medical and IT scientists exist, each publishing in their own area, but where do these research pathways meet? Could the proposed IT plans have any clinical effect and do clinicians really understand the limitations of VCE software? In this Review, we present an in-depth critical analysis that aims to inspire and align the agendas of the two scientific groups.

  4. A primary intestinal lymphangiectasia patient diagnosed by capsule endoscopy and confirmed at surgery: A case report

    PubMed Central

    Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao

    2007-01-01

    Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination. PMID:17465517

  5. Design of a Lossless Image Compression System for Video Capsule Endoscopy and Its Performance in In-Vivo Trials

    PubMed Central

    Khan, Tareq H.; Wahid, Khan A.

    2014-01-01

    In this paper, a new low complexity and lossless image compression system for capsule endoscopy (CE) is presented. The compressor consists of a low-cost YEF color space converter and variable-length predictive with a combination of Golomb-Rice and unary encoding. All these components have been heavily optimized for low-power and low-cost and lossless in nature. As a result, the entire compression system does not incur any loss of image information. Unlike transform based algorithms, the compressor can be interfaced with commercial image sensors which send pixel data in raster-scan fashion that eliminates the need of having large buffer memory. The compression algorithm is capable to work with white light imaging (WLI) and narrow band imaging (NBI) with average compression ratio of 78% and 84% respectively. Finally, a complete capsule endoscopy system is developed on a single, low-power, 65-nm field programmable gate arrays (FPGA) chip. The prototype is developed using circular PCBs having a diameter of 16 mm. Several in-vivo and ex-vivo trials using pig's intestine have been conducted using the prototype to validate the performance of the proposed lossless compression algorithm. The results show that, compared with all other existing works, the proposed algorithm offers a solution to wireless capsule endoscopy with lossless and yet acceptable level of compression. PMID:25375753

  6. Small bowel capsule endoscopy: Where are we after almost 15 years of use?

    PubMed Central

    Van de Bruaene, Cedric; De Looze, Danny; Hindryckx, Pieter

    2015-01-01

    The development of capsule endoscopy (CE) in 2001 has given gastroenterologists the opportunity to investigate the small bowel in a non-invasive way. CE is most commonly performed for obscure gastrointestinal bleeding, but other indications include diagnosis or follow-up of Crohn’s disease, suspicion of a small bowel tumor, diagnosis and surveillance of hereditary polyposis syndromes, Nonsteroidal anti-inflammatory drug-induced small bowel lesions and celiac disease. Almost fifteen years have passed since the release of the small bowel capsule. The purpose of this review is to offer the reader a brief but complete overview on small bowel CE anno 2014, including the technical and procedural aspects, the possible complications and the most important indications. We will end with some future perspectives of CE. PMID:25610531

  7. Detecting esophageal disease with second-generation capsule endoscopy: initial evaluation of the PillCam ESO 2.

    PubMed

    Gralnek, I M; Adler, S N; Yassin, K; Koslowsky, B; Metzger, Y; Eliakim, R

    2008-04-01

    Esophageal capsule endoscopy (ECE) provides an alternative, minimally invasive modality for evaluating the esophagus. This study evaluates the performance and test characteristics of a second-generation esophageal capsule endoscope, the PillCam ESO 2. Adults with known or suspected esophageal disease were included. Using the simplified ingestion procedure, each patient underwent capsule endoscopy with the PillCam ESO 2. Following ECE, esophagogastroduodenoscopy (EGD) was performed on the same day by an investigator who was blinded to the results of the ECE. In random order, capsule endoscopy videos were read and interpreted by the study investigator blinded to EGD results. 28 patients (19 men, 9 women; mean age 53.3 years) were included. In 82 % of the patients, at least 75 % of the Z line was visualized by the PillCam ESO 2. A per-lesion analysis demonstrated that the PillCam ESO 2 had definitive results in 30/43 lesions (69.8 %) and EGD in 29/43 (67.4 %), P value = 0.41. Compared with EGD for detecting suspected Barrett's esophagus and esophagitis, the PillCam ESO 2 had a sensitivity of 100 % and a specificity of 74 %, and a sensitivity of 80 % and a specificity of 87 %, respectively. The PillCam ESO 2 demonstrated 86 % agreement with EGD in describing the Z line (kappa statistic 0.68). The modified ingestion protocol provided excellent cleansing, with bubbles/saliva having no or only a minor effect on Z line images in 86 % of cases. The PillCam ESO 2 demonstrated excellent visualization of the Z line. Compared with standard EGD, the PillCam ESO 2 had good test characteristics with high rates of detection of suspected Barrett's esophagus and esophagitis. This study provides indirect validation of the simplified ingestion procedure. The PillCam ESO 2 acquires high quality esophageal images, performs safely, and should be able to replace the current PillCam ESO.

  8. Development of an Implantable WBAN Path-Loss Model for Capsule Endoscopy

    NASA Astrophysics Data System (ADS)

    Aoyagi, Takahiro; Takizawa, Kenichi; Kobayashi, Takehiko; Takada, Jun-Ichi; Hamaguchi, Kiyoshi; Kohno, Ryuji

    An implantable WBAN path-loss model for a capsule endoscopy which is used for examining digestive organs, is developed by conducting simulations and experiments. First, we performed FDTD simulations on implant WBAN propagation by using a numerical human model. Second, we performed FDTD simulations on a vessel that represents the human body. Third, we performed experiments using a vessel of the same dimensions as that used in the simulations. On the basis of the results of these simulations and experiments, we proposed the gradient and intercept parameters of the simple path-loss in-body propagation model.

  9. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals.

    PubMed

    Kobaek-Larsen, M; Kroijer, R; Dyrvig, A-K; Buijs, M M; Steele, R J C; Qvist, N; Baatrup, G

    2018-06-01

    The aim was to determine the polyp detection rate and per-patient sensitivity for polyps > 9 mm of colon capsule endoscopy (CCE) compared with colonoscopy as well as the diagnostic accuracy of CCE. Individuals who had a positive immunochemical faecal occult blood test during screening had investigator blinded CCE and colonoscopy. Participants underwent repeat endoscopy if significant lesions detected by CCE were considered to have been missed by colonoscopy. There were 253 participants. The polyp detection rate was significantly higher in CCE compared with colonoscopy (P = 0.02). The per-patient sensitivity for > 9 mm polyps for CCE and colonoscopy was 87% (95% CI: 83-91%) and 88% (95% CI: 84-92%) respectively. In participants with complete CCE and colonoscopy examinations (N = 126), per-patient sensitivity of > 9 mm polyps in CCE (97%; 95% CI: 94-100%) was superior to colonoscopy (89%; 95% CI: 84-94%). A complete capsule endoscopy examination (N = 134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp > 10 mm or more than two polyps. CCE is superior to colonoscopy in polyp detection rate and per-patient sensitivity to > 9 mm polyps, but only in complete CCE examinations. The rate of incomplete CCE examinations must be improved. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  10. OMOM capsule endoscopy in diagnosis of small bowel disease

    PubMed Central

    Li, Chen-yi; Zhang, Bing-ling; Chen, Chun-xiao; Li, You-ming

    2008-01-01

    Objective: To assess the diagnostic efficiency of OMOM capsule endoscopy (CE) in a group of patients with different indications. Methods: Data from 89 consecutive patients (49 males, 40 females) with suspected small bowel disease who underwent OMOM CE (Jinshan Science and Technology Company, Chongqing, China) examination were obtained by retrospective review. The patients’ indications of the disease consisted of the following: obscure gastrointestinal bleeding (OGIB), abdominal pain or diarrhea, partial intestinal obstruction, suspected inflammatory bowel disease, tumor of unknown origin, hypoproteinemia, constipation, weight loss, and elevated tumor markers. Results: CE failed in one patient. Visualization of the entire small bowel was achieved in 75.0%. Capsules were naturally excreted by all patients. The detection rate of abnormalities was 70.5% for patients with suspected small bowel disease, and the diagnostic yield for patients with OGIB was higher than that for patients with abdominal pain or diarrhea (85.7% vs 53.3%, P<0.005). Angiodysplasia was the most common small bowel finding. Active bleeding sites were noted in the small intestine in 11 cases. Conclusion: OMOM CE is a useful diagnostic tool for the diagnosis of variably suspected small bowel disease, whose diagnostic efficiency is similar to that of the Pillcam SB (small bowel) CE (Given Imaging, Yoqneam, Israel). PMID:18988304

  11. Diagnostic yield of capsule endoscopy in refractory celiac disease.

    PubMed

    Barret, Maximilien; Malamut, Georgia; Rahmi, Gabriel; Samaha, Elia; Edery, Joël; Verkarre, Virginie; Macintyre, Elizabeth; Lenain, Emilie; Chatellier, Gilles; Cerf-Bensussan, Nadine; Cellier, Christophe

    2012-10-01

    Capsule endoscopy (CE) allows for the assessment of the small bowel in numerous intestinal diseases, including celiac disease (CD). The main advantage of CE is the complete visualization of the intestinal mucosal surface. The objective of this study was to investigate whether CE can predict the severity of CD and detect complications. We retrospectively studied the medical files of 9 patients with symptomatic CD, 11 patients with refractory celiac disease type I (RCDI) and 18 patients with refractory celiac disease type II (RCDII), and 45 patients without CD who were investigated both CE and upper endoscopy or enteroscopy. The type of CD was diagnosed on the basis of a centralized histological review, flow cytometry analysis of intraepithelial lymphocytes, and the analysis of T-cell receptor rearrangement by multiplex polymerase chain reaction. A total of 47 CEs (10, 11, and 26 CEs in the symptomatic CD, RCDI, and RCDII groups, respectively) from the 38 celiac patients and 47 CEs from the 45 nonceliac patients were retrospectively reviewed. Villous atrophy, numerous, or distally located ulcers were more frequent in celiac patients than in controls. Among celiac patients, CE was of acceptable quality in 96% of cases and was complete in 62% of cases. The concordance of CE with histology for villous atrophy was better than that of optic endoscopy (κ coefficient =0.45 vs. 0.24, P<0.001). Extensive mucosal damage on CE was associated with low serum albumin (P=0.003) and the RCDII form (P=0.02). Three cases of overt lymphoma were detected by CE during the follow-up. CE findings have a satisfactory concordance with histology and nutritional status in patients with symptomatic or refractory CD. Moreover, CE may predict the type of RCD and allows for the early detection of overt lymphoma.

  12. Advanced Image Enhancement Method for Distant Vessels and Structures in Capsule Endoscopy

    PubMed Central

    Pedersen, Marius

    2017-01-01

    This paper proposes an advanced method for contrast enhancement of capsule endoscopic images, with the main objective to obtain sufficient information about the vessels and structures in more distant (or darker) parts of capsule endoscopic images. The proposed method (PM) combines two algorithms for the enhancement of darker and brighter areas of capsule endoscopic images, respectively. The half-unit weighted-bilinear algorithm (HWB) proposed in our previous work is used to enhance darker areas according to the darker map content of its HSV's component V. Enhancement of brighter areas is achieved thanks to the novel threshold weighted-bilinear algorithm (TWB) developed to avoid overexposure and enlargement of specular highlight spots while preserving the hue, in such areas. The TWB performs enhancement operations following a gradual increment of the brightness of the brighter map content of its HSV's component V. In other words, the TWB decreases its averaged weights as the intensity content of the component V increases. Extensive experimental demonstrations were conducted, and, based on evaluation of the reference and PM enhanced images, a gastroenterologist (Ø.H.) concluded that the PM enhanced images were the best ones based on the information about the vessels, contrast in the images, and the view or visibility of the structures in more distant parts of the capsule endoscopy images. PMID:29225668

  13. Gastrointestinal bleeding detection in wireless capsule endoscopy images using handcrafted and CNN features.

    PubMed

    Xiao Jia; Meng, Max Q-H

    2017-07-01

    Gastrointestinal (GI) bleeding detection plays an essential role in wireless capsule endoscopy (WCE) examination. In this paper, we present a new approach for WCE bleeding detection that combines handcrafted (HC) features and convolutional neural network (CNN) features. Compared with our previous work, a smaller-scale CNN architecture is constructed to lower the computational cost. In experiments, we show that the proposed strategy is highly capable when training data is limited, and yields comparable or better results than the latest methods.

  14. Reduction of capsule endoscopy reading times by unsupervised image mining.

    PubMed

    Iakovidis, D K; Tsevas, S; Polydorou, A

    2010-09-01

    The screening of the small intestine has become painless and easy with wireless capsule endoscopy (WCE) that is a revolutionary, relatively non-invasive imaging technique performed by a wireless swallowable endoscopic capsule transmitting thousands of video frames per examination. The average time required for the visual inspection of a full 8-h WCE video ranges from 45 to 120min, depending on the experience of the examiner. In this paper, we propose a novel approach to WCE reading time reduction by unsupervised mining of video frames. The proposed methodology is based on a data reduction algorithm which is applied according to a novel scheme for the extraction of representative video frames from a full length WCE video. It can be used either as a video summarization or as a video bookmarking tool, providing the comparative advantage of being general, unbounded by the finiteness of a training set. The number of frames extracted is controlled by a parameter that can be tuned automatically. Comprehensive experiments on real WCE videos indicate that a significant reduction in the reading times is feasible. In the case of the WCE videos used this reduction reached 85% without any loss of abnormalities.

  15. Portable wireless power transmission system for video capsule endoscopy.

    PubMed

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  16. Gastrografin as an alternative booster to sodium phosphate in colon capsule endoscopy: safety and efficacy pilot study*

    PubMed Central

    Togashi, Kazutomo; Fujita, Tomoki; Utano, Kenichi; Waga, Eriko; Katsuki, Shinichi; Isohata, Noriyuki; Endo, Shungo; Lefor, Alan K.

    2015-01-01

    Background and study aims: Sodium phosphate is a key component of bowel preparation regimen for colon capsule endoscopy (CCE), but may cause serious complications. The aim of this study is to evaluate the use of Gastrografin, substituted for sodium phosphate, in CCE bowel preparation. Patients and methods: In total, 29 patients (median age 64 years; 23 females) underwent CCE, covered by the national health insurance system of Japan. All had a history of laparotomy and/or previously incomplete colonoscopy. On the day before examination, patients ingested 1 L of polyethylene glycol + ascorbic acid with 0.5 L of water in the evening, and again the same laxative on the morning of examination. After capsule ingestion, 50 mL of Gastrografin diluted with 0.9 L of magnesium citrate was administered, and then repeated after 1 hour. Results: The capsule excretion rate was 97 % (28/29). The median colon transit time was 2 hours 45 minutes and rapid transit (< 40 minutes) through the colon occurred in one patient (3.4 %). Bowel cleansing level was adequate in 90 % of patients. The polyp (≥ 6 mm) detection rate was 52 %. Diluted Gastrografin was well tolerated by patients. No adverse events occurred. Conclusion: Gastrografin can be an alternative to sodium phosphate in CCE bowel preparation regimen. PMID:26716132

  17. Lubiprostone neither decreases gastric and small-bowel transit time nor improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled study.

    PubMed

    Hooks, S Bennett; Rutland, Travis J; Di Palma, Jack A

    2009-11-01

    Lubiprostone, a selective activator of type 2 chloride channels, is approved for treatment of chronic idiopathic constipation and recently constipation-predominant irritable bowel syndrome. It has been suggested that lubiprostone has a prokinetic effect. This investigation was designed to evaluate lubiprostone as a preparation and propulsive agent for small-bowel capsule endoscopy. The PillCam Small Bowel capsule endoscopy system with the PillCam SB1 capsule and Rapid 5 software platform were used. The study was designed as a double-blind, placebo-controlled trial. Forty healthy adults. Gastric transit time (GTT), small-bowel transit time (SBTT), and adequacy of small-bowel cleansing preparation. The study subjects received 24 mug lubiprostone or placebo 30 minutes before PillCam capsule ingestion. Capsule endoscopy studies were read by 2 independent investigators unaware of the study medication received, and differences in interpretation were resolved by consensus. Anatomical landmarks were identified, and GTT and SBTT were calculated. Overall preparation quality assessment of the proximal, mid, and distal small bowel was determined by using a 4-step scale. The percentage of visualized bowel was determined by review of 10-minute video segments at 1-hour intervals after the capsule passed through the pylorus. In the lubiprostone group (n = 20), 2 subjects did not pass the capsule through the pylorus in the 8-hour battery life of the capsule. An additional 3 capsules did not pass into the colon. In the placebo group (n = 20), all capsules passed into the small bowel, but 1 did not pass into the colon. The subjects in whom the capsule did not pass into the small bowel were excluded from the small-bowel analysis. In the subjects in whom the capsule did reach the colon, the SBTT could not be calculated and they were excluded from SBTT analysis. The mean GTT in the lubiprostone group was 126 minutes and 43 minutes in the placebo group (P = .0095). The mean SBTT in the

  18. Capsule endoscopy in neoplastic diseases

    PubMed Central

    Pennazio, Marco; Rondonotti, Emanuele; de Franchis, Roberto

    2008-01-01

    Until recently, diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High-quality images of the small-bowel mucosa may be captured and small and flat lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings, remains to be determined through carefully-designed studies. PMID:18785274

  19. Effects of empty bins on image upscaling in capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Rukundo, Olivier

    2017-07-01

    This paper presents a preliminary study of the effect of empty bins on image upscaling in capsule endoscopy. The presented study was conducted based on results of existing contrast enhancement and interpolation methods. A low contrast enhancement method based on pixels consecutiveness and modified bilinear weighting scheme has been developed to distinguish between necessary empty bins and unnecessary empty bins in the effort to minimize the number of empty bins in the input image, before further processing. Linear interpolation methods have been used for upscaling input images with stretched histograms. Upscaling error differences and similarity indices between pairs of interpolation methods have been quantified using the mean squared error and feature similarity index techniques. Simulation results demonstrated more promising effects using the developed method than other contrast enhancement methods mentioned.

  20. Wireless capsule endoscopy for diagnosis of acute intestinal graft-versus-host disease.

    PubMed

    Neumann, Susanne; Schoppmeyer, Konrad; Lange, Thoralf; Wiedmann, Marcus; Golsong, Johannes; Tannapfel, Andrea; Mossner, Joachim; Niederwieser, Dietger; Caca, Karel

    2007-03-01

    The small intestine is the most common location of intestinal graft-versus-host disease (GVHD). EGD with duodenal biopsies yields the highest diagnostic sensitivity, but the jejunum and ileum are not accessible by regular endoscopy. In contrast, wireless capsule endoscopy (WCE) is a noninvasive imaging procedure offering complete evaluation of the small intestine. The objective was to compare the diagnostic value of EGD, including biopsies, with the results of WCE in patients with acute intestinal symptoms who received allogeneic blood stem cell transplantation and to analyze the appearance and distribution of acute intestinal GVHD lesions in these patients. An investigator-blinded, single-center prospective study. Patients with acute intestinal symptoms after allogeneic stem cell transplantation underwent both EGD and WCE within 24 hours. Clinical data were recorded during 2 months of follow-up. Fourteen consecutive patients with clinical symptoms of acute intestinal GVHD were recruited. In 1 patient, the capsule remained in the stomach and was removed endoscopically. In 7 of 13 patients who could be evaluated, acute intestinal GVHD was diagnosed by EGD with biopsies, but 3 of these would have been missed by EGD alone. In all 7 patients with histologically confirmed acute intestinal GVHD, WCE revealed typical signs of GVHD. Lesions were scattered throughout the small intestine, but were most accentuated in the ileum. This study had a small number of patients. WCE, which is less invasive than EGD with biopsies, showed a comparable sensitivity and a high negative predictive value for diagnosing acute intestinal GVHD. It may be helpful to avoid repeated endoscopic procedures in patients who have undergone stem cell transplantation.

  1. Thermo-mechanical actuator-based miniature tagging module for localization in capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Chandrappan, Jayakrishnan; Ruiqi, Lim; Su, Nandar; Yen Yi, Germaine Hoe; Vaidyanathan, Kripesh

    2011-04-01

    Capsule endoscopy is a frontline medical diagnostic tool for the gastro intestinal tract disorders. During diagnosis, efficient localization techniques are essential to specify a pathological area that may require further diagnosis or treatment. This paper presents the development of a miniature tagging module that relies on a novel concept to label the region of interest and has the potential to integrate with a capsule endoscope. The tagging module is a compact thermo-mechanical actuator loaded with a biocompatible micro tag. A low power microheater attached to the module serves as the thermal igniter for the mechanical actuator. At optimum temperature, the actuator releases the micro tag instantly and penetrates the mucosa layer of a GI tract, region of interest. Ex vivo animal trials are conducted to verify the feasibility of the tagging module concept. X-ray imaging is used to detect the location of the micro tag embedded in the GI tract wall. The method is successful, and radiopaque micro tags can provide valuable pre-operative position information on the infected area to facilitate further clinical procedures.

  2. Is the use of AGILE patency capsule prior to videocapsule endoscopy useful in all patients with spondyloarthritis?

    PubMed

    Gheorghe, Andrada; Zahiu, Denise Carmen Mihaela; Voiosu, Theodor Alexandru; Mateescu, Bogdan Radu; Voiosu, Mihail Radu; Rimbaş, Mihai

    2017-06-01

    As already known, spondyloarthritis patients present a striking resemblance in intestinal inflammation with early Crohn's disease. Moreover, the frequent use of nonsteroidal anti-inflammatory drugs is an important part of their treatment. Both conditions could lead to intestinal stenoses. Therefore we proposed to investigate the usefulness of the patency capsule test in patients with spondyloarthritis. 64 consecutive patients (33 males; mean age 38 ± 11 years) that fulfilled the AMOR criteria for seronegative spondyloarthropathy (59.4% ankylosing spondylitis) lacking symptoms or signs of intestinal stenosis were enrolled and submitted to an AGILE™ capsule patency test followed by a video capsule endoscopy (PillCam SB2™), as part of a protocol investigating the presence of intestinal inflammatory lesions. After reviewing the VCE recordings, the Lewis score (of small bowel inflammatory involvement) was computed. In only 5 patients (7.8%) of the study group, the luminal patency test was negative. However, there was no retention of the videocapsule in any of the patients. From the 59 patients with a positive patency test, 3 patients presented single small bowel stenoses (two with ulcerated overlying inflamed mucosa, one cicatricial), all being traversed by the videocapsule along the length of the recording. None of the patients with a negative test had bowel stenoses. There was no correlation between the patency test and the Lewis score, the C reactive protein value, diagnosis of inflammatory bowel disease, or the family history of spondyloarthritis, psoriasis or inflammatory bowel disease. The AGILE patency capsule does not seem to be a useful tool for all patients with spondyloarthritis prior to small bowel videocapsule endoscopy (ClinicalTrial.gov ID NCT 00768950).

  3. Colon Capsule Endoscopy: Where Are We and Where Are We Going

    PubMed Central

    Han, Yoo Min; Im, Jong Pil

    2016-01-01

    Colon capsule endoscopy (CCE) is a noninvasive technique for diagnostic imaging of the colon. It does not require air inflation or sedation and allows minimally invasive and painless colonic evaluation. The role of CCE is rapidly evolving; for example, for colorectal screening (colorectal cancer [CRC]) in average-risk patients, in patients with an incomplete colonoscopy, in patients refusing a conventional colonoscopy, and in patients with contraindications for conventional colonoscopy. In this paper, we comprehensively review the technical characteristics and procedure of CCE and compare CCE with conventional methods such as conventional colonoscopy or computed tomographic colonography. Future expansion of CCE in the area of CRC screening for the surveillance of polyps and adenomatous lesions and for assessment of inflammatory bowel disease is also discussed. PMID:27653441

  4. Lubiprostone decreases the small bowel transit time by capsule endoscopy: an exploratory, randomised, double-blind, placebo-controlled 3-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Endo, Hiroki; Matsuura, Tetsuya; Kanoshima, Kenji; Inoh, Yumi; Fujita, Yuji; Umezawa, Shotaro; Fuyuki, Akiko; Uchiyama, Shiori; Higurashi, Takuma; Ohkubo, Hidenori; Sakai, Eiji; Iida, Hiroshi; Nonaka, Takashi; Futagami, Seiji; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2014-01-01

    The aim of this study was to investigate the usefulness of lubiprostone for bowel preparation and as a propulsive agent in small bowel endoscopy. Six healthy male volunteers participated in this randomized, 3-way crossover study. The subjects received a 24 μg tablet of lubiprostone 60 minutes prior to the capsule ingestion for capsule endoscopy (CE) and a placebo tablet 30 minutes before the capsule ingestion (L-P regimen), a placebo tablet 60 minutes prior to CE and a 24 μg tablet of lubiprostone 30 minutes prior to CE (P-L regimen), or a placebo tablet 60 minutes prior to r CE and a placebo tablet again 30 minutes prior to CE (P-P regimen). The quality of the capsule endoscopic images and the amount of water in the small bowel were assessed on 5-point scale. The median SBTT was 178.5 (117-407) minutes in the P-P regimen, 122.5 (27-282) minutes in the L-P regimen, and 110.5 (11-331) minutes in the P-L regimen (P = 0.042). This study showed that the use of lubiprostone significantly decreased the SBTT. We also confirmed that lubiprostone was effective for inducing water secretion into the small bowel during CE.

  5. Oral purgative and simethicone before small bowel capsule endoscopy

    PubMed Central

    Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José

    2013-01-01

    AIM: To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. METHODS: Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. RESULTS: There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered

  6. Oral purgative and simethicone before small bowel capsule endoscopy.

    PubMed

    Rosa, Bruno Joel Ferreira; Barbosa, Mara; Magalhães, Joana; Rebelo, Ana; Moreira, Maria João; Cotter, José

    2013-02-16

    To evaluate small bowel cleansing quality, diagnostic yield and transit time, comparing three cleansing protocols prior to capsule endoscopy. Sixty patients were prospectively enrolled and randomized to one of the following cleansing protocols: patients in Group A underwent a 24 h liquid diet and overnight fasting; patients in Group B followed protocol A and subsequently were administered 2 L of polyethylene glycol (PEG) the evening before the procedure; patients in Group C followed protocol B and were additionally administered 100 mg of simethicone 30 min prior to capsule ingestion. Small bowel cleansing was independently assessed by two experienced endoscopists and classified as poor, fair, good or excellent according to the proportion of small bowel mucosa under perfect conditions for visualization. When there was no agreement between the two endoscopists, the images were reviewed and discussed until a consensus was reached. The preparation was considered acceptable if > 50% or adequate if > 75% of the mucosa was in perfect cleansing condition. The amount of bubbles was assessed independently and it was considered significant if it prevented a correct interpretation of the images. Positive endoscopic findings, gastric emptying time (GET) and small bowel transit time (SBTT) were recorded for each examination. There was a trend favoring Group B in achieving an acceptable (including fair, good or excellent) level of cleansing (Group A: 65%; Group B: 83.3%; Group C: 68.4%) [P = not significant (NS)] and favoring Group C in attaining an excellent level of cleansing (Group A: 10%; Group B: 16.7%; Group C: 21.1%) (P = NS). The number of patients with an adequate cleansing of the small bowel, corresponding to an excellent or good classification, was 5 (25%) in Group A, 5 (27.8%) in Group B and 4 (21.1%) in Group C (P = 0.892). Conversely, 7 patients (35%) in Group A, 3 patients (16.7%) in Group B and 6 patients (31.6%) in Group C were considered to have poor small bowel

  7. Colon Capsule Endoscopy compared to Conventional Colonoscopy under routine screening conditions

    PubMed Central

    2010-01-01

    Background Colonoscopy (CSPY) for colorectal cancer screening has several limitations. Colon Capsule Endoscopy (PillCam Colon, CCE) was compared to CSPY under routine screening conditions. Methods We performed a prospective, single-center pilot study at a University Hospital. Data were obtained from November 2007 until May 2008. Patients underwent CCE on Day 1 and CSPY on Day 2. Outcomes were evaluated regarding sensitivity and specificity of polyp detection rate, with a significance level set at >5 mm. Results 59 individuals were included in this study, the results were evaluable in 56 patients (males 34, females 22; median age 59). CCE was complete in 36 subjects. Polyp detection rate for significant polyps was 11% on CSPY and 27% on CCE. 6/56 (11%) patients had polyps on CSPY not detected on CCE (miss rate). Overall sensitivity was 79% (95% confidence interval [CI], 61 to 90), specificity was 54% (95% CI, 35 to 70), positive predictive value (PPV) was 63% and negative predictive value (NPV) was 71%. Adjusted to significance of findings, sensitivity was 50% (95% CI, 19 to 81), specificity was 76% (95% CI, 63 to 86), PPV was 20% and NPV was 93%. Conclusion In comparison to the gold standard, the sensitivity of CCE for detection of relevant polyps is low, however, the high NPV supports its role as a possible screening tool. Trial Registration NCT00991003. PMID:20565828

  8. Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Buselli, Elisa; Pensabene, Virginia; Castrataro, Piero; Valdastri, Pietro; Menciassi, Arianna; Dario, Paolo

    2010-10-01

    Capsule endoscopy is an emerging field in medical technology. Despite very promising innovations, some critical issues are yet to be addressed, such as the management and possible exploitation of the friction in the gastrointestinal environment in order to control capsule locomotion more actively. This paper presents the fabrication and testing of bio-inspired polymeric micro-patterns, which are arrays of cylindrical pillars fabricated via soft lithography. The aim of the work is to develop structures that enhance the grip between an artificial device and the intestinal tissue, without injuring the mucosa. In fact, the patterns are intended to be mounted on microfabricated legs of a capsule robot that is able to move actively in the gastrointestinal tract, thus improving the robot's traction ability. The effect of micro-patterned surfaces on the leg-slipping behaviour on colon walls was investigated by considering both different pillar dimensions and the influence of tissue morphology. Several in vitro tests on biological samples demonstrated that micro-patterns of pillars made from a soft polymer with an aspect ratio close to 1 enhanced friction by 41.7% with regard to flat surfaces. This work presents preliminary modelling of the friction and adhesion forces in the gastrointestinal environment and some design guidelines for endoscopic devices.

  9. Capsule endoscopy—A mechatronics perspective

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  10. Detection of small bowel tumors in capsule endoscopy frames using texture analysis based on the discrete wavelet transform.

    PubMed

    Barbosa, Daniel J C; Ramos, Jaime; Lima, Carlos S

    2008-01-01

    Capsule endoscopy is an important tool to diagnose tumor lesions in the small bowel. The capsule endoscopic images possess vital information expressed by color and texture. This paper presents an approach based in the textural analysis of the different color channels, using the wavelet transform to select the bands with the most significant texture information. A new image is then synthesized from the selected wavelet bands, trough the inverse wavelet transform. The features of each image are based on second-order textural information, and they are used in a classification scheme using a multilayer perceptron neural network. The proposed methodology has been applied in real data taken from capsule endoscopic exams and reached 98.7% sensibility and 96.6% specificity. These results support the feasibility of the proposed algorithm.

  11. Assessment of an electronic learning system for colon capsule endoscopy: a pilot study.

    PubMed

    Watabe, Hirotsugu; Nakamura, Tetsuya; Yamada, Atsuo; Kakugawa, Yasuo; Nouda, Sadaharu; Terano, Akira

    2016-06-01

    Training for colon capsule endoscopy (CCE) procedures is currently performed as a lecture and hands-on seminar. The aims of this pilot study were to assess the utility of an electronic learning system for CCE (ELCCE) designed for the Japanese Association for Capsule Endoscopy using an objective scoring engine, and to evaluate the efficacy of ELCCE on the acquisition of CCE reading competence. ELCCE is an Internet-based learning system with the following steps: step 1, introduction; step 2, CCE reading competence assessment test (CCAT), which evaluates the competence of CCE reading prior to training; step 3, learning reading theory; step 4, training with guidance; step 5, training without guidance; step 6, final assessment; and step 7, the same as step 2. The CCAT, step 5 and step 6 were scored automatically according to: lesion detection, diagnosis (location, size, shape of lesion), management recommendations, and quality of view. Ten trainee endoscopists were initially recruited (cohort 1), followed by a validating cohort of 11 trainee endoscopists (cohort 2). All but one participant finished ELCCE training within 7 weeks. In step 6, accuracy ranged from 53 to 98 % and was not impacted by step 2 pretest scores. The average CCAT scores significantly increased between step 2 pretest and step 7 in both cohorts, from 42 ± 18 % to 79 ± 15 % in cohort 1 (p = 0.0004), and from 52 ± 15 % to 79 ± 14 % in cohort 2 (p = 0.0003). ELCCE is useful and effective for improving CCE reading competence.

  12. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule

    PubMed Central

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases. PMID:26600772

  13. Capsule Endoscope Aspiration after Repeated Attempts for Ingesting a Patency Capsule.

    PubMed

    Mannami, Tomohiko; Ikeda, Genyo; Seno, Satoru; Sonobe, Hiroshi; Fujiwara, Nobukiyo; Komoda, Minori; Edahiro, Satoru; Ohtawa, Yasuyuki; Fujimoto, Yoshimi; Sato, Naohiro; Kambara, Takeshi; Waku, Toshihiko

    2015-01-01

    Capsule endoscope aspiration into the respiratory tract is a rare complication of capsule endoscopy. Despite the potential seriousness of this complication, no accepted methods exist to accurately predict and therefore prevent it. We describe the case of an 85-year-old male who presented for evaluation of iron deficiency anemia. He complained of dysphagia while ingesting a patency capsule, with several attempts over a period of 5 min before he was successful. Five days later, he underwent capsule endoscopy, where he experienced similar symptoms in swallowing the capsule. The rest of the examination proceeded uneventfully. On reviewing the captured images, the capsule endoscope was revealed to be aspirated, remaining in the respiratory tract for approximately 220 s before images of the esophagus and stomach appeared. To our knowledge, this is the first documented case of a patient who experienced capsule endoscope aspiration after ingestion of a patency capsule. This case suggests that repeated attempts required for ingesting the patency capsule can predict capsule endoscope aspiration. We presume that paying sufficient attention to the symptoms of a patient who ingests a patency capsule could help us prevent serious complications such as aspiration of the capsule endoscope. In addition, this experience implies the potential risk for ingesting the patency capsule. We must be aware that the patency capsule could also be aspirated and there may be more unrecognized aspiration cases.

  14. Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.

    PubMed

    Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel

    2017-01-01

    The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  15. Lubiprostone improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled 2-way crossover study.

    PubMed

    Matsuura, Mizue; Inamori, Masahiko; Inou, Yumi; Kanoshima, Kenji; Higurashi, Takuma; Ohkubo, Hidenori; Iida, Hiroshi; Endo, Hiroki; Nonaka, Takashi; Kusakabe, Akihiko; Maeda, Shin; Nakajima, Atsushi

    2017-06-01

     Lubiprostone has been reported to be an anti-constipation drug. The aim of the study was to investigate the usefulness of lubiprostone both for bowel preparation and as a propulsive agent in small bowel endoscopy.  This was a double-blind, placebo-controlled, 2-way crossover study of subjects who volunteered to undergo capsule endoscopy (CE). A total of 20 subjects (16 male and 4 female volunteers) were randomly assigned to receive a 24-μg tablet of lubiprostone 120 minutes prior to capsule ingestion for CE (L regimen), or a placebo tablet 120 minutes prior to capsule ingestion for CE (P regimen). Main outcome was gastric transit time (GTT) and small-bowel transit time (SBTT). Secondary outcome was adequacy of small-bowel cleansing and the fluid score in the small bowel. The quality of the capsule endoscopic images and fluid in the small bowel were assessed on 5-point scale.  The capsule passed into the small bowel in all cases. Median GTT was 57.3 (3 - 221) minutes for the P regimen and 61.3 (10 - 218) minutes for the L regimen ( P  = 0.836). Median SBTT was 245.0 (164 - 353) minutes for the P regimen and 228.05 (116 - 502) minutes for the L regimen ( P  = 0.501). The image quality score in the small bowel was 3.05 ± 1.08 for the P regimen and 3.80 ± 0.49 for the L regimen ( P  < 0.001). The fluid score in the small bowel was 2.04 ± 1.58 for the P regimen and 2.72 ± 1.43 for the L regimen ( P  < 0.001). There was a significant difference between the 2 regimens with regard to image quality. The fluid score was more plentiful for the L regimen than for the P regimen. There were no cases of capsule retention or serious adverse events in this study.  Our study showed that use of lubiprostone prior to CE significantly improved visualization of the small bowel during CE as a result of inducing fluid secretion into the small bowel.

  16. Semantic and topological classification of images in magnetically guided capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Mewes, P. W.; Rennert, P.; Juloski, A. L.; Lalande, A.; Angelopoulou, E.; Kuth, R.; Hornegger, J.

    2012-03-01

    Magnetically-guided capsule endoscopy (MGCE) is a nascent technology with the goal to allow the steering of a capsule endoscope inside a water filled stomach through an external magnetic field. We developed a classification cascade for MGCE images with groups images in semantic and topological categories. Results can be used in a post-procedure review or as a starting point for algorithms classifying pathologies. The first semantic classification step discards over-/under-exposed images as well as images with a large amount of debris. The second topological classification step groups images with respect to their position in the upper gastrointestinal tract (mouth, esophagus, stomach, duodenum). In the third stage two parallel classifications steps distinguish topologically different regions inside the stomach (cardia, fundus, pylorus, antrum, peristaltic view). For image classification, global image features and local texture features were applied and their performance was evaluated. We show that the third classification step can be improved by a bubble and debris segmentation because it limits feature extraction to discriminative areas only. We also investigated the impact of segmenting intestinal folds on the identification of different semantic camera positions. The results of classifications with a support-vector-machine show the significance of color histogram features for the classification of corrupted images (97%). Features extracted from intestinal fold segmentation lead only to a minor improvement (3%) in discriminating different camera positions.

  17. Small bowel cleansing for capsule endoscopy in paediatric patients: a prospective randomized single-blind study.

    PubMed

    Oliva, Salvatore; Cucchiara, Salvatore; Spada, Cristiano; Hassan, Cesare; Ferrari, Federica; Civitelli, Fortunata; Pagliaro, Giuseppe; Di Nardo, Giovanni

    2014-01-01

    Small bowel cleansing by capsule endoscopy has never been addressed in children. Randomized controlled trial to evaluate the effect of five bowel preparation regimens on the mucosal visibility surface (as percentage of visualized surface area). Group A: a clear liquid diet for 12 h on the day before; Group B: high volume polyethylene glycol (50 mL/kg, up to 2Lt/die); Group C: low volume polyethylene glycol (25 mL/kg up to 1Lt/die); Group D: 20 mL (376 mg) of oral simethicone; Group E: 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone. Overall, 198 patients (53% male, median age 13 years) were enrolled. Preparation regimen visualization scores were 14.1 ± 4.2, 18.9 ± 5.1, 17.8 ± 5.5, 14.9 ± 4.8 and 20.9 ± 4.6 in groups A, B, C, D and E, respectively (P < 0.01). Positive findings were found in 172 cases (87%), but no significant differences were observed in the diagnostic yield and tolerability. Interobserver agreement, k = 0.89 (95% CI 0.83 ± 0.71). This is the first report in children that supports the use of 25 mL/kg (up to 1Lt/die) of polyethylene glycol solution plus 20 mL (376 mg) of oral simethicone as the preparation of choice for capsule endoscopy. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Automated Adaptive Brightness in Wireless Capsule Endoscopy Using Image Segmentation and Sigmoid Function.

    PubMed

    Shrestha, Ravi; Mohammed, Shahed K; Hasan, Md Mehedi; Zhang, Xuechao; Wahid, Khan A

    2016-08-01

    Wireless capsule endoscopy (WCE) plays an important role in the diagnosis of gastrointestinal (GI) diseases by capturing images of human small intestine. Accurate diagnosis of endoscopic images depends heavily on the quality of captured images. Along with image and frame rate, brightness of the image is an important parameter that influences the image quality which leads to the design of an efficient illumination system. Such design involves the choice and placement of proper light source and its ability to illuminate GI surface with proper brightness. Light emitting diodes (LEDs) are normally used as sources where modulated pulses are used to control LED's brightness. In practice, instances like under- and over-illumination are very common in WCE, where the former provides dark images and the later provides bright images with high power consumption. In this paper, we propose a low-power and efficient illumination system that is based on an automated brightness algorithm. The scheme is adaptive in nature, i.e., the brightness level is controlled automatically in real-time while the images are being captured. The captured images are segmented into four equal regions and the brightness level of each region is calculated. Then an adaptive sigmoid function is used to find the optimized brightness level and accordingly a new value of duty cycle of the modulated pulse is generated to capture future images. The algorithm is fully implemented in a capsule prototype and tested with endoscopic images. Commercial capsules like Pillcam and Mirocam were also used in the experiment. The results show that the proposed algorithm works well in controlling the brightness level accordingly to the environmental condition, and as a result, good quality images are captured with an average of 40% brightness level that saves power consumption of the capsule.

  19. Global-constrained hidden Markov model applied on wireless capsule endoscopy video segmentation

    NASA Astrophysics Data System (ADS)

    Wan, Yiwen; Duraisamy, Prakash; Alam, Mohammad S.; Buckles, Bill

    2012-06-01

    Accurate analysis of wireless capsule endoscopy (WCE) videos is vital but tedious. Automatic image analysis can expedite this task. Video segmentation of WCE into the four parts of the gastrointestinal tract is one way to assist a physician. The segmentation approach described in this paper integrates pattern recognition with statiscal analysis. Iniatially, a support vector machine is applied to classify video frames into four classes using a combination of multiple color and texture features as the feature vector. A Poisson cumulative distribution, for which the parameter depends on the length of segments, models a prior knowledge. A priori knowledge together with inter-frame difference serves as the global constraints driven by the underlying observation of each WCE video, which is fitted by Gaussian distribution to constrain the transition probability of hidden Markov model.Experimental results demonstrated effectiveness of the approach.

  20. Suture marker lesion detection in the colon by self-stabilizing and unmodified capsule endoscopes: pilot study in acute canine models.

    PubMed

    Filip, Dobromir; Yadid-Pecht, Orly; Muench, Gregory; Mintchev, Martin P; Andrews, Christopher N

    2013-02-01

    Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. Experimental study in a live canine model. Four dogs. Laparotomy, capsule endoscopy, colonoscopy. Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. The proposed self-stabilizing capsule endoscope delivered a significant improvement in

  1. A video wireless capsule endoscopy system powered wirelessly: design, analysis and experiment

    NASA Astrophysics Data System (ADS)

    Pan, Guobing; Xin, Wenhui; Yan, Guozheng; Chen, Jiaoliao

    2011-06-01

    Wireless capsule endoscopy (WCE), as a relatively new technology, has brought about a revolution in the diagnosis of gastrointestinal (GI) tract diseases. However, the existing WCE systems are not widely applied in clinic because of the low frame rate and low image resolution. A video WCE system based on a wireless power supply is developed in this paper. This WCE system consists of a video capsule endoscope (CE), a wireless power transmission device, a receiving box and an image processing station. Powered wirelessly, the video CE has the abilities of imaging the GI tract and transmitting the images wirelessly at a frame rate of 30 frames per second (f/s). A mathematical prototype was built to analyze the power transmission system, and some experiments were performed to test the capability of energy transferring. The results showed that the wireless electric power supply system had the ability to transfer more than 136 mW power, which was enough for the working of a video CE. In in vitro experiments, the video CE produced clear images of the small intestine of a pig with the resolution of 320 × 240, and transmitted NTSC format video outside the body. Because of the wireless power supply, the video WCE system with high frame rate and high resolution becomes feasible, and provides a novel solution for the diagnosis of the GI tract in clinic.

  2. Effect of erythromycin on image quality and transit time of capsule endoscopy: A two-center study

    PubMed Central

    Niv, Eva; Bogner, Ido; Barkay, Olga; Halpern, Zamir; Mahajna, Elisabeth; Depsames, Roman; Kopelman, Yael; Fireman, Zvi

    2008-01-01

    AIM: To compare the effect of oral erythromycin vs no preparation with prokinetics on the transit time and the image quality of capsule endoscopy (CE) in evaluating small bowel (SB) pathology. METHODS: We conducted a retrospective, blinded (to the type of preparation) review of 100 CE studies, 50 with no preparation with prokinetics from one medical center (Group A) and 50 from another center with administration of a single dose of 200 mg oral erythromycin 1 h prior to CE (Group B). Gastric, SB and total transit times were calculated, the presence of bile in the duodenum was scored, as was cleanliness within the proximal, middle and distal intestine. RESULTS: The erythromycin group had a slightly shorter gastric transit time (21 min vs 28 min, with no statistical significance). SB transit time was similar for both groups (all P > 0.05). Total transit time was almost identical in both groups. The rate of incomplete examination was 16% for Group A and 10% for Group B (P = 0.37). Bile and cleanliness scores in different parts of the intestine were similar for the two groups (P > 0.05). CONCLUSION: Preparation for capsule endoscopy with erythromycin does not affect SB or total transit time. It tends to reduce gastric transit time, but it does not increase the cecum-reaching rate. Erythromycin does not adversely affect image quality. We consider the routine use of oral erythromycin preparation as being unjustified, although it might be considered in patients with known prolonged gastric emptying time. PMID:18442206

  3. Identification of the duodenal papilla by colon capsule endoscope.

    PubMed

    Karagiannis, S; Dücker, C; Dautel, P; Strubenhoff, J; Faiss, S

    2010-07-01

    The sensitivity of small-bowel capsule endoscopy in visualizing a single finding present in everyone, the duodenal papilla, is limited. In this retrospective case series study we evaluated whether the duodenal papilla can be better visualized by a capsule endoscope equipped with cameras on both ends. The recordings of 45 colonic capsule endoscopies (PillCam Colon) performed in a single tertiary center were re-evaluated seeking for the duodenal papilla. The two-hour sleeping period of the colon capsule endoscopy system led to the imaging of duodenum in 10 / 45 patients. The duodenal papilla was identified in 6 / 10 (60 %) patients while the number of frames where the papilla was clearly visualized ranged from 2 - 9. Consequently, a small-bowel capsule endoscope containing two cameras could better identify the duodenal papilla and theoretically other obscure areas of the small bowel, expanding its diagnostic accuracy.

  4. Automatic patient-adaptive bleeding detection in a capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Jung, Yun Sub; Kim, Yong Ho; Lee, Dong Ha; Lee, Sang Ho; Song, Jeong Joo; Kim, Jong Hyo

    2009-02-01

    We present a method for patient-adaptive detection of bleeding region for a Capsule Endoscopy (CE) images. The CE system has 320x320 resolution and transmits 3 images per second to receiver during around 10-hour. We have developed a technique to detect the bleeding automatically utilizing color spectrum transformation (CST) method. However, because of irregular conditions like organ difference, patient difference and illumination condition, detection performance is not uniform. To solve this problem, the detection method in this paper include parameter compensation step which compensate irregular image condition using color balance index (CBI). We have investigated color balance through sequential 2 millions images. Based on this pre-experimental result, we defined ΔCBI to represent deviate of color balance compared with standard small bowel color balance. The ΔCBI feature value is extracted from each image and used in CST method as parameter compensation constant. After candidate pixels were detected using CST method, they were labeled and examined with a bleeding character. We tested our method with 4,800 images in 12 patient data set (9 abnormal, 3 normal). Our experimental results show the proposed method achieves (before patient adaptive method : 80.87% and 74.25%, after patient adaptive method : 94.87% and 96.12%) of sensitivity and specificity.

  5. Role of capsule endoscopy in suspected celiac disease: A European multi-centre study

    PubMed Central

    Luján-Sanchis, Marisol; Pérez-Cuadrado-Robles, Enrique; García-Lledó, Javier; Juanmartiñena Fernández, José-Francisco; Elli, Luca; Jiménez-García, Victoria-Alejandra; Egea-Valenzuela, Juan; Valle-Muñoz, Julio; Carretero-Ribón, Cristina; Fernández-Urién-Sainz, Ignacio; López-Higueras, Antonio; Alonso-Lázaro, Noelia; Sanjuan-Acosta, Mileidis; Sánchez-Ceballos, Francisco; Rosa, Bruno; González-Vázquez, Santiago; Branchi, Federica; Ruano-Díaz, Lucía; Prieto-de-Frías, César; Pons-Beltrán, Vicente; Borque-Barrera, Pilar; González-Suárez, Begoña; Xavier, Sofía; Argüelles-Arias, Federico; Herrerías-Gutiérrez, Juan-Manuel; Pérez-Cuadrado-Martínez, Enrique; Sempere-García-Argüelles, Javier

    2017-01-01

    AIM To analyze the diagnostic yield (DY), therapeutic impact (TI) and safety of capsule endoscopy (CE). METHODS This is a multi-centre, observational, analytical, retrospective study. A total of 163 patients with suspicion of celiac disease (CD) (mean age = 46.4 ± 17.3 years, 68.1% women) who underwent CE from 2003 to 2015 were included. Patients were divided into four groups: seronegative CD with atrophy (Group-I, n = 19), seropositive CD without atrophy (Group-II, n = 39), contraindication to gastroscopy (Group-III, n = 6), seronegative CD without atrophy, but with a compatible context (Group-IV, n = 99). DY, TI and the safety of CE were analysed. RESULTS The overall DY was 54% and the final diagnosis was villous atrophy (n = 65, 39.9%), complicated CD (n = 12, 7.4%) and other enteropathies (n = 11, 6.8%; 8 Crohn’s). DY for groups I to IV was 73.7%, 69.2%, 50% and 44.4%, respectively. Atrophy was located in duodenum in 24 cases (36.9%), diffuse in 19 (29.2%), jejunal in 11 (16.9%), and patchy in 10 cases (15.4%). Factors associated with a greater DY were positive serology (68.3% vs 49.2%, P = 0.034) and older age (P = 0.008). On the other hand, neither sex nor clinical presentation, family background, positive histology or HLA status were associated with DY. CE results changed the therapeutic approach in 71.8% of the cases. Atrophy was associated with a greater TI (92.3% vs 45.3%, P < 0.001) and 81.9% of the patients responded to diet. There was one case of capsule retention (0.6%). Agreement between CE findings and subsequent histology was 100% for diagnosing normal/other conditions, 70% for suspected CD and 50% for complicated CD. CONCLUSION CE has a high DY in cases of suspicion of CD and it leads to changes in the clinical course of the disease. CE is safe procedure with a high degree of concordance with histology and it helps in the differential diagnosis of CD. PMID:28216978

  6. An artificial neural network architecture for non-parametric visual odometry in wireless capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Dimas, George; Iakovidis, Dimitris K.; Karargyris, Alexandros; Ciuti, Gastone; Koulaouzidis, Anastasios

    2017-09-01

    Wireless capsule endoscopy is a non-invasive screening procedure of the gastrointestinal (GI) tract performed with an ingestible capsule endoscope (CE) of the size of a large vitamin pill. Such endoscopes are equipped with a usually low-frame-rate color camera which enables the visualization of the GI lumen and the detection of pathologies. The localization of the commercially available CEs is performed in the 3D abdominal space using radio-frequency (RF) triangulation from external sensor arrays, in combination with transit time estimation. State-of-the-art approaches, such as magnetic localization, which have been experimentally proved more accurate than the RF approach, are still at an early stage. Recently, we have demonstrated that CE localization is feasible using solely visual cues and geometric models. However, such approaches depend on camera parameters, many of which are unknown. In this paper the authors propose a novel non-parametric visual odometry (VO) approach to CE localization based on a feed-forward neural network architecture. The effectiveness of this approach in comparison to state-of-the-art geometric VO approaches is validated using a robotic-assisted in vitro experimental setup.

  7. Multicenter, randomized study to optimize bowel preparation for colon capsule endoscopy

    PubMed Central

    Kastenberg, David; Jr, Wilmot C Burch; Romeo, David P; Kashyap, Pankaj K; Pound, David C; Papageorgiou, Neophytos; Sainz, Ignacio Fernández-Urien; Sokach, Carly E; Rex, Douglas K

    2017-01-01

    AIM To assess the cleansing efficacy and safety of a new Colon capsule endoscopy (CCE) bowel preparation regimen. METHODS This was a multicenter, prospective, randomized, controlled study comparing two CCE regimens. Subjects were asymptomatic and average risk for colorectal cancer. The second generation CCE system (PillCam® COLON 2; Medtronic, Yoqneam, Israel) was utilized. Preparation regimens differed in the 1st and 2nd boosts with the Study regimen using oral sulfate solution (89 mL) with diatrizoate meglumine and diatrizoate sodium solution (“diatrizoate solution”) (boost 1 = 60 mL, boost 2 = 30 mL) and the Control regimen oral sulfate solution (89 mL) alone. The primary outcome was overall and segmental colon cleansing. Secondary outcomes included safety, polyp detection, colonic transit, CCE completion and capsule excretion ≤ 12 h. RESULTS Both regimens had similar cleansing efficacy for the whole colon (Adequate: Study = 75.9%, Control = 77.3%; P = 0.88) and individual segments. In the Study group, CCE completion was superior (Study = 90.9%, Control = 76.9%; P = 0.048) and colonic transit was more often < 40 min (Study = 21.8%, Control = 4%; P = 0.0073). More Study regimen subjects experienced adverse events (Study = 19.4%, Control = 3.4%; P = 0.0061), and this difference did not appear related to diatrizoate solution. Adverse events were primarily gastrointestinal in nature and no serious adverse events related either to the bowel preparation regimen or the capsule were observed. There was a trend toward higher polyp detection with the Study regimen, but this did not achieve statistical significance for any size category. Mean transit time through the entire gastrointestinal tract, from ingestion to excretion, was shorter with the Study regimen while mean colonic transit times were similar for both study groups. CONCLUSION A CCE bowel preparation regimen using oral sulfate solution and diatrizoate solution as a boost agent is effective, safe, and

  8. [Diagnostic yield of video capsule endoscopy in premenopausal women with iron-deficiency anemia].

    PubMed

    Garrido Durán, Carmen; Iyo Miyashiro, Eduardo; Páez Cumpa, Claudia; Khorrami Minaei, Sam; Erimeiku Barahona, Alicia; Llompart Rigo, Alfredo

    2015-01-01

    Clinical practice guidelines recommend video capsule endoscopy (VCE) studies in patients with iron-deficiency anemia (IDA) after conventional upper and lower endoscopies but there is a need for studies demonstrating the diagnostic yield, clinical impact, and cost in some patient subgroups. 1.To determine the diagnostic yield of VCE in premenopausal women with IDA compared with that in men and postmenopausal women. 2. To identify the presence of VCE predictors in premenopausal women. 3. To estimate the cost-clinical impact relationship associated with VCE in this indication. We retrospectively analyzed 408 patients who underwent VCE. Patients with IDA were enrolled (premenopausal, postmenopausal women, and men), with previous normal work-up by conventional endoscopies. A total of 249 patients were enrolled: 131 women (52.6%), of which 51 were premenopausal and 80 were post-menopausal, and 118 men. The mean age was 60.7±16 years. The diagnostic yield of VCE for the diagnosis of IDA was 44.6% (95% CI 39.9 - 50.8). Diagnostic yield was 50.8% vs 38.9% in men vs women (p=0.05) and was 55% vs 13.7% in postmenopausal vs premenopausal women (p<0.001). No predictors of small bowel lesions were found in premenopausal women. The most common findings in the postmenopausal group were angioectasias (70.5%) and erosions (57.1%) in the premenopausal group. The cost in premenopausal women was 44.727€ and 86.3% of the procedures had no clinical impact. The diagnostic yield of VCE is low in the etiological study of IDA in premenopausal women and there is no cost-effectiveness in relation to clinical impact. No predictors of small bowel lesions were found in this group. Copyright © 2015 Elsevier España, S.L.U. and AEEH y AEG. All rights reserved.

  9. Current Status and Research into Overcoming Limitations of Capsule Endoscopy

    PubMed Central

    Kwack, Won Gun; Lim, Yun Jeong

    2016-01-01

    Endoscopic investigation has a critical role in the diagnosis and treatment of gastrointestinal (GI) diseases. Since 2001, capsule endoscopy (CE) has been available for small-bowel exploration and is under continuous development. During the past decade, CE has achieved impressive improvements in areas such as miniaturization, resolution, and battery life. As a result, CE is currently a first-line tool for the investigation of the small bowel in obscure gastrointestinal bleeding and is a useful alternative to wired enteroscopy. Nevertheless, CE still has several limitations, such as incomplete examination and limited diagnostic and therapeutic capabilities. To resolve these problems, many groups have suggested several models (e.g., controlled CO2 insufflation system, magnetic navigation system, mobile robotic platform, tagging and biopsy equipment, and targeted drug-delivery system), which are in development. In the near future, new technological advances will improve the capabilities of CE and broaden its spectrum of applications not only for the small bowel but also for the colon, stomach, and esophagus. The purpose of this review is to introduce the current status of CE and to review the ongoing development of solutions to address its limitations. PMID:26855917

  10. Detecting PHG frames in wireless capsule endoscopy video by integrating rough global dominate-color with fine local texture features

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoqi; Wang, Chengliang; Bai, Jianying; Liao, Guobin

    2018-02-01

    Portal hypertensive gastropathy (PHG) is common in gastrointestinal (GI) diseases, and a severe stage of PHG (S-PHG) is a source of gastrointestinal active bleeding. Generally, the diagnosis of PHG is made visually during endoscopic examination; compared with traditional endoscopy, (wireless capsule endoscopy) WCE with noninvasive and painless is chosen as a prevalent tool for visual observation of PHG. However, accurate measurement of WCE images with PHG is a difficult task due to faint contrast and confusing variations in background gastric mucosal tissue for physicians. Therefore, this paper proposes a comprehensive methodology to automatically detect S-PHG images in WCE video to help physicians accurately diagnose S-PHG. Firstly, a rough dominatecolor-tone extraction approach is proposed for better describing global color distribution information of gastric mucosa. Secondly, a hybrid two-layer texture acquisition model is designed by integrating co-occurrence matrix into local binary pattern to depict complex and unique gastric mucosal microstructure local variation. Finally, features of mucosal color and microstructure texture are merged into linear support vector machine to accomplish this automatic classification task. Experiments were implemented on an annotated data set including 1,050 SPHG and 1,370 normal images collected from 36 real patients of different nationalities, ages and genders. By comparison with three traditional texture extraction methods, our method, combined with experimental results, performs best in detection of S-PHG images in WCE video: the maximum of accuracy, sensitivity and specificity reach 0.90, 0.92 and 0.92 respectively.

  11. Analysis of small-bowel capsule endoscopy reading by using Quickview mode: training assistants for reading may produce a high diagnostic yield and save time for physicians.

    PubMed

    Shiotani, Akiko; Honda, Keisuke; Kawakami, Makiko; Kimura, Yoshiki; Yamanaka, Yoshiyuki; Fujita, Minoru; Matsumoto, Hiroshi; Tarumi, Ken-ichi; Manabe, Noriaki; Haruma, Ken

    2012-01-01

    The aim was to investigate the clinical utility of RAPID Access 6.5 Quickview software and to evaluate whether preview of the capsule endoscopy video by a trained nurse could detect significant lesions accurately compared with endoscopists. As reading capsule endoscopy is time consuming, one possible cost-effective strategy could be the use of trained nonphysicians or newly available software to preread and identify potentially important capsule images. The 100 capsule images of a variety of significant lesions from 87 patients were investigated. The minimum percentages for settings of sensitivity that could pick up the selected images and the detection rate for significant lesions by a well-trained nurse, two endoscopists with limited experience in reading, and one well-trained physician were examined. The frequency of the selected lesions picked up by Quickview mode using percentages for sensitivity settings of 5%, 15%, 25%, and 35% were 61%, 74%, 93%, and 98%, respectively. The percentages for sensitivity significantly correlated (r=0.78, P<0.001) with the reading time. The detection rate by the nurse or the well-trained physician was significantly higher than that by the physician with limited capsule experience (87% and 84.1% vs. 62.7%; P<0.01). The clinical use of Quickview at 25% did not significantly improve the detection rate. Quickview mode can reduce reading time but has an unacceptably miss rate for potentially important lesions. Use of a trained nonphysician assistant can reduce physician's time and improve diagnostic yield.

  12. Laparotomy and intraoperative enteroscopy for obscure gastrointestinal bleeding before and after the era of video capsule endoscopy and deep enteroscopy: a tertiary center experience

    PubMed Central

    Manatsathit, Wuttiporn; Khrucharoen, Usah; Jensen, Dennis M.; Hines, O. Joe; Kovacs, Thomas; Ohning, Gordon; Jutabha, Rome; Ghassemi, Kevin; Dulai, Gareth S.; Machicado, Gustavo

    2017-01-01

    Background To evaluate roles of intraoperative endoscopy (IOE) in management of severe obscure GI bleeding (OGIB) before vs. after introduction of video capsule endoscopy (VCE) and deep enteroscopy (DE). Methods We retrospectively reviewed prospectively collected data of patients undergoing IOE for severe OGIB in a tertiary referral center. Results 52 patients had laparotomy/IOE for OGIB, 11 pre and 41 post VCE/DE eras. In the pre VCE/DE era, 36.4% (4/11) had preoperative presumptive diagnoses while in the post VCE/DE era presumptive diagnoses were made in 48.8% (20/41) (p= 0.18). Preoperative evaluation led to correct diagnoses in 18.2% (2/11) in the pre and 51.2% (21/41) in the post VCE/DE era (p=0.09). Vascular lesions and ulcers were the most common diagnoses, but rebleeding was common. No rebleeding was found among patients with tumors, Meckel's diverticulum, and aortoenteric fistula. Conclusions Presumptive diagnoses in the post VCE/DE era were usually accurate. If VCE or DE are negative, the probability of negative IOE is high. Patients with tumors and Meckel's diverticulum were the best candidates for IOE. PMID:28629608

  13. Bowel preparations for capsule endoscopy: a comparison between simethicone and magnesium citrate.

    PubMed

    Esaki, Motohiro; Matsumoto, Takayuki; Kudo, Tetsuji; Yanaru-Fujisawa, Ritsuko; Nakamura, Shotaro; Iida, Mitsuo

    2009-01-01

    Bowel preparation for capsule endoscopy (CE) has not been standardized. This study aimed to compare CE images between patients prepared by simethicone and those prepared by magnesium citrate. Retrospective analysis of case series of our hospital from 2004 to 2007. Single center. CE images of 75 patients receiving bowel preparation either by 200 mg of simethicone (n=39) or by 34 g of magnesium citrate (n=36) were retrospectively investigated. Grades of fluid transparency and mucosal invisibility by air bubbles and food residue were compared between the 2 preparations. Capsule transit time, frequency of positive findings, and interobserver variations between 2 observers were also investigated. Image quality and diagnostic yield of CE. Fluid transparency in the first and the third time segments of the small intestine was better in patients prepared by magnesium citrate than in those prepared by simethicone (P= .001 and P= .03, respectively). On the other hand, mucosal invisibility was not different in any part of the small intestine between the 2 groups. Neither gastric transit time nor small-bowel transit time was different between the 2 groups. The diagnostic yield of CE correlated significantly with fluid transparency (P= .04), but it did not correlate with mucosal invisibility. Single-center retrospective study. Magnesium citrate seems to be a recommended preparation for CE compared with simethicone. The fluid transparency, rather than the mucosal invisibility, may be a factor associated with the diagnostic yield of CE.

  14. Manipulation of permanent magnetic polymer micro-robots: a new approach towards guided wireless capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Hilbich, D.; Rahbar, A.; Khosla, A.; Gray, B. L.

    2012-10-01

    We present the initial experimental results for manipulating micro-robots featuring permanent magnetic polymer magnets for guided wireless endoscopy applications. The magnetic polymers are fabricated by doping polydimethylsiloxane (PDMS) with permanent isotropic rare earth magnetic powder (MQFP 12-5) with an average particle size of 6 μm. The prepared magnetic nanocomposite polymer (M-NCP) is patterned in the desired shape against a plexiglass mold via soft lithography techniques. It is observed that the fabricated micro-robot magnets have a magnetic field strength of 50 mT and can easily be actuated by applying a field of 8.3 mT (field measured at the capsule's position) and moved at a rate of 5 inches/second.

  15. How much helpful is the capsule endoscopy for the diagnosis of small bowel lesions?

    PubMed Central

    Ersoy, Osman; Sivri, Bulent; Arslan, Serap; Batman, Figen; Bayraktar, Yusuf

    2006-01-01

    AIM: To assess the practically usefulness and diagnostic yield of this new method in a group of patients with suspected small bowel lesions. METHODS: Capsule endoscopic (CE) examination by using M2A capsule endoscope TM (Given Imaging, Yoqneam, Israel) was performed in thirty nine patients (26 males, 13 females) with suspected small intestinal lesions. The composing of the patients was as follows: obscure gastrointestinal bleeding in twenty three patients, known Crohn’s disease in 6 patients, in whom CE was used to evaluate the severity and extension of the diseases, chronic diarrhea in 8 patients, abdominal pain in one patient and malignancy in one patient with unknown origin. RESULTS: In two patients CE failed. Different abnormalities were revealed in 26 patients overall. Detection rate of abnormalities was highest among patients with obscure gastrointestinal bleeding and the source of bleeding was demonstrated in 17 of 23 patients with obscure bleeding (73.9%). Entero-Behcet was diagnosed in two patients by CE as a source of obscure gastrointestinal bleeding. In 6 patients with known Crohn's disease, CE revealed better evaluation of the disease extension. In 3 of 8 (37.5%) patients with chronic diarrhea; CE revealed some mucosal abnormalities as the cause of chronic diarrhea. In a patient with unexplained abdominal pain and in a cancer patient with unknown origin, CE examination was normal. CONCLUSION: In our relatively small series, we found that capsule endoscopy is a useful diagnostic tool particularly in diagnosis of obscure gastrointestinal bleeding, chronic diarrhea and in estimating the extension of Crohn’s disease. PMID:16804980

  16. Morpho-functional evaluation of small bowel using wireless motility capsule and video capsule endoscopy in patients with known or suspected Crohn's disease: pilot study.

    PubMed

    Yung, Diana; Douglas, Sarah; Hobson, Anthony R; Giannakou, Andry; Plevris, John N; Koulaouzidis, Anastasios

    2016-04-01

    SmartPill(®) (Given Imaging Corp.,Yoqneam,Israel) is an ingestible, non-imaging capsule that records physiological data including contractions and pH throughout the gastrointestinal tract. There are scarce data looking at SmartPill(®) assessment of patients with known/suspected small-bowel Crohn's Disease (CD). This pilot study aims to investigate feasibility and safety of SmartPill(®) to assess gut motility in this group.  Over 1 year, patients with known/suspected CD, referred for small-bowel capsule endoscopy (SBCE), were invited to participate and 12 were recruited (7 female, 5 male, mean age 44.2 ± 16.6 years). They underwent hydrogen breath test to exclude small-bowel bacterial overgrowth, patency capsule (Agile(®)), and provided stool samples for fecal calprotectin (FC). Patients ingested PillCam(®)SB2 and SmartPill(®) 4 hours apart. Using unpublished data, 33 healthy controls also were identified for the study. P < 0.05 was considered statistically significant. Of the 12 patients enrolled, 10 underwent complete Smartpill(®) examination (1 stomach retention, 1 dropout). Pillcam(®) was complete in 10 (1 dropout, 1 stomach retention). Mean fecal calprotectin was 340 ± 307.71 mcg/g. The study group had longer transit times and lower gut motility index than did the controls. The difference in motility appears to be statistically significant (P < 0.05). Longer transit times for SmartPill(®) (not statistically significant) may have been due to different specifications between the capsules. Limitations included transient Smartpill(®) signal loss (5/10 studies). This is the first pilot to attempt combining SBCE and SmartPill(®) to assess small-bowel CD. Data on motility in CD are scarce. Multimodal information can provide a clearer clinical picture. Despite concerns about capsule retention in CD patients, SmartPill(®) seems safe for use if a patency capsule is employed beforehand.

  17. Colour-reproduction algorithm for transmitting variable video frames and its application to capsule endoscopy

    PubMed Central

    Khan, Tareq; Shrestha, Ravi; Imtiaz, Md. Shamin

    2015-01-01

    Presented is a new power-efficient colour generation algorithm for wireless capsule endoscopy (WCE) application. In WCE, transmitting colour image data from the human intestine through radio frequency (RF) consumes a huge amount of power. The conventional way is to transmit all R, G and B components of all frames. Using the proposed dictionary-based colour generation scheme, instead of sending all R, G and B frames, first one colour frame is sent followed by a series of grey-scale frames. At the receiver end, the colour information is extracted from the colour frame and then added to colourise the grey-scale frames. After a certain number of grey-scale frames, another colour frame is sent followed by the same number of grey-scale frames. This process is repeated until the end of the video sequence to maintain the colour similarity. As a result, over 50% of RF transmission power can be saved using the proposed scheme, which will eventually lead to a battery life extension of the capsule by 4–7 h. The reproduced colour images have been evaluated both statistically and subjectively by professional gastroenterologists. The algorithm is finally implemented using a WCE prototype and the performance is validated using an ex-vivo trial. PMID:26609405

  18. Video capsule endoscopy after bariatric and gastric surgery: oral ingestion is associated with satisfactory completion rate.

    PubMed

    Stanich, Peter P; Kleinman, Bryan; Porter, Kyle M; Meyer, Marty M

    2015-01-01

    To investigate the outcomes of video capsule endoscopy (VCE) performed on patients after bariatric and gastric surgery with a focus on delivery method (oral ingestion or endoscopic placement). There is minimal published data regarding the use of VCE in patients after bariatric and gastric surgery and the optimal delivery method is unknown. Retrospective case series of patients with bariatric or gastric surgery undergoing VCE in a tertiary care center over 3 years. Outcomes of interest were completion of the procedure and bowel transit times. Twenty-three patients met study criteria. They underwent 24 VCE in the study period, with 13/16 (81.3%; 95% CI, 54%-96%) completed to the colon after oral ingestion and 5/8 (62.5%; 95% CI, 24%-91%) completed after endoscopic deployment. The median gastric transit time after oral ingestion was <1 minute (IQR, <1 to 99). Median total transit time after oral ingestion was 291 minutes (IQR, 213 to 434) and after endoscopic deployment was 364 minutes (IQR, 233 to >440) (P=0.48). There were no instances of capsule retention. Oral ingestion of VCE resulted in a satisfactory completion rate with rapid gastric transit after bariatric and gastric surgery. There were no capsule retention events. Given this and the favorable risk and cost profile, oral ingestion should be favored over endoscopic placement in this patient population.

  19. A two-hop wireless power transfer system with an efficiency-enhanced power receiver for motion-free capsule endoscopy inspection.

    PubMed

    Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Zhihua

    2012-11-01

    This paper presents a wireless power transfer system for a motion-free capsule endoscopy inspection. Conventionally, a wireless power transmitter in a specifically designed jacket has to be connected to a strong power source with a long cable. To avoid the power cable and allow patients to walk freely in a room, this paper proposes a two-hop wireless power transfer system. First, power is transferred from a floor to a power relay in the patient's jacket via strong coupling. Next, power is delivered from the power relay to the capsule via loose coupling. Besides making patients much more conformable, the proposed techniques eliminate the sources of reliability issues arisen from the moving cable and connectors. In the capsule, it is critical to enhance the power conversion efficiency. This paper develops a switch-mode rectifier (rectifying efficiency of 93.6%) and a power combination circuit (enhances combining efficiency by 18%). Thanks to the two-hop transfer mechanism and the novel circuit techniques, this system is able to transfer an average power of 24 mW and a peak power of 90 mW from the floor to a 13 mm × 27 mm capsule over a distance of 1 m with the maximum dc-to-dc power efficiency of 3.04%.

  20. Gastric digestion of α-lactalbumin in adult human subjects using capsule endoscopy and nasogastric tube sampling.

    PubMed

    Sullivan, Louise M; Kehoe, Joseph J; Barry, Lillian; Buckley, Martin J M; Shanahan, Fergus; Mok, K H; Brodkorb, André

    2014-08-28

    In the present study, structural changes in the milk protein α-lactalbumin (α-LA) and its proteolysis were investigated for the potential formation of protein-fatty acid complexes during in vivo gastric digestion. Capsule endoscopy allowed visualisation of the digestion of the test drinks, with nasogastric tubes allowing sampling of the gastric contents. A total of ten healthy volunteers had nasogastric tubes inserted into the stomach and ingested test drinks containing 50 g/l of sucrose and 25 g/l of α-LA with and without 4 g/l of oleic acid (OA). The samples of gastric contents were collected for analysis at 3 min intervals. The results revealed a rapid decrease in the pH of the stomach of the subjects. The fasting pH of 2·31 (SD 1·19) increased to a pH maxima of pH 6·54 (SD 0·29) after ingestion, with a subsequent decrease to pH 2·22 (SD 1·91) after 21 min (n 8). Fluorescence spectroscopy and Fourier transform IR spectroscopy revealed partial protein unfolding, coinciding with the decrease in pH below the isoelectric point of α-LA. The activity of pepsin in the fasting state was found to be 39 (SD 12) units/ml of gastric juice. Rapid digestion of the protein occurred: after 15 min, no native protein was detected using SDS-PAGE; HPLC revealed the presence of small amounts of native protein after 24 min of gastric digestion. Mirocam® capsule endoscopy imaging and video clips (see the online supplementary material) revealed that gastric peristalsis resulted in a heterogeneous mixture during gastric digestion. Unfolding of α-LA was observed during gastric transit; however, there was no evidence of a cytotoxic complex being formed between α-LA and OA.

  1. Are bowel purgatives and prokinetics useful for small-bowel capsule endoscopy? A prospective randomized controlled study.

    PubMed

    Postgate, Aymer; Tekkis, Paris; Patterson, Neil; Fitzpatrick, Aine; Bassett, Paul; Fraser, Chris

    2009-05-01

    Capsule endoscopy (CE) is limited by incomplete small-bowel transit and poor view quality in the distal bowel. Currently, there is no consensus regarding the use of bowel purgatives or prokinetics in CE. To evaluate the usefulness of bowel purgatives and prokinetics in small-bowel CE. Prospective single-blind randomized controlled study. Academic endoscopy unit. A total of 150 patients prospectively recruited. Patients were randomized to 1 of 4 preparations: "standard" (fluid restriction then nothing by mouth 12 hours before the procedure, water and simethicone at capsule ingestion [S]); "standard" + 10 mg oral metoclopramide before the procedure (M); Citramag + senna bowel-purgative regimen the evening before CE (CS); Citramag + senna + 10 mg metoclopramide before the procedure (CSM). Gastric transit time (GTT) and small-bowel transit time (SBTT), completion rates (CR), view quality, and patient acceptability. positive findings, diagnostic yield. No significant difference was noted among groups for GTT (median [minutes] M, CS, and CSM vs S: 17.3, 24.7, and 15.1 minutes vs 16.8 minutes, respectively; P = .62, .18, and .30, respectively), SBTT (median [minutes] M, CS, and CSM vs S: 260, 241, and 201 vs 278, respectively; P = .91, .81, and .32, respectively), or CRs (85%, 85%, and 88% vs 89% for M, CS, and CSM vs S, respectively; P = .74, .74, and 1.00, respectively). There was no significant difference in view quality among groups (of 44: 38, 37, and 40 vs 37 for M, CS, and CSM, vs S, respectively; P = .18, .62, and .12, respectively). Diagnostic yield was similar among the groups. CS and CSM regimens were significantly less convenient (P < .001), and CS was significantly less comfortable (P = .001) than standard preparation. Bowel purgatives and prokinetics do not improve CRs or view quality at CE, and bowel purgatives reduce patient acceptability.

  2. Randomized Controlled Trial of Cholestyramine and Hydrotalcite to Eliminate Bile for Capsule Endoscopy

    PubMed Central

    Hong-Bin, Chen; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Yue, Zhang; Xiao-Lin, Li

    2016-01-01

    Background/Aims: Bile is the main cause of poor bowel preparation for capsule endoscopy (CE). We aimed to determine whether cholestyramine and hydrotalcite can eliminate bile in the bowel. Patients and Methods: Patients undergoing CE were randomized into two groups. Group A patients (n = 75) recieved 250 mL 20% mannitol and 1 L 0.9% saline orally at 20:00 hours on the day before and at 05:00 hours on the day of CE and 20 mL simethicone 30 min before CE. Group B patients (n = 73) were treated identically, except for taking oral cholestyramine and hydrotalcite, starting 3 days before CE. Greenish luminal contents were assessed by four tissue color bar segments using Color Area Statistics software. Bowel cleanliness was evaluated by visualized area percentage assessment of cleansing (AAC) score. Result: Bowel cleanliness (82.7% [62/75] vs 46.6% [34/73]; χ2 = 14.596, P = 0.000). and detected greenish luminal contents (20.0% [15/75] vs 8.2% [6/73]; χ2 = 4.217, P = 0.040) were significantly greater in Group A than in Group B. Greenish luminal contents in the two groups differed significantly in the captured small-bowel (t = −13.74, P = 0.000) segments and proximal small-bowel (t = −0.7365, P = 0.000) segments, but not for the distal small-bowel (t = −0.552, P = 0.581) segments. Conclusions: Cholestyramine and hydrotalcite were ineffective in eliminating bile and improving small-bowel preparation. PMID:26997218

  3. Retained Wireless Capsule Endoscope in a Girl with suspected Crohn's Disease.

    PubMed

    Herle, Koushik; Jehangir, Susan

    2016-01-01

    Wireless capsule endoscopy (WCE) is one of the great milestones in the field of gastroenterology. It is versatile in image acquisition, painless and can reach parts of the small bowel not amenable to conventional endoscopy. The commonest complication with WCE is retention of the capsule. We report a case of retained capsule in a child who was being investigated for obscure gastrointestinal bleeding (OGIB). Operative intervention was required for its retrieval after two weeks of expectant management.

  4. Automatic lesion detection in capsule endoscopy based on color saliency: closer to an essential adjunct for reviewing software.

    PubMed

    Iakovidis, Dimitris K; Koulaouzidis, Anastasios

    2014-11-01

    The advent of wireless capsule endoscopy (WCE) has revolutionized the diagnostic approach to small-bowel disease. However, the task of reviewing WCE video sequences is laborious and time-consuming; software tools offering automated video analysis would enable a timelier and potentially a more accurate diagnosis. To assess the validity of innovative, automatic lesion-detection software in WCE. A color feature-based pattern recognition methodology was devised and applied to the aforementioned image group. This study was performed at the Royal Infirmary of Edinburgh, United Kingdom, and the Technological Educational Institute of Central Greece, Lamia, Greece. A total of 137 deidentified WCE single images, 77 showing pathology and 60 normal images. The proposed methodology, unlike state-of-the-art approaches, is capable of detecting several different types of lesions. The average performance, in terms of the area under the receiver-operating characteristic curve, reached 89.2 ± 0.9%. The best average performance was obtained for angiectasias (97.5 ± 2.4%) and nodular lymphangiectasias (96.3 ± 3.6%). Single expert for annotation of pathologies, single type of WCE model, use of single images instead of entire WCE videos. A simple, yet effective, approach allowing automatic detection of all types of abnormalities in capsule endoscopy is presented. Based on color pattern recognition, it outperforms previous state-of-the-art approaches. Moreover, it is robust in the presence of luminal contents and is capable of detecting even very small lesions. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  5. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases.

    PubMed

    Ladas, S D; Triantafyllou, K; Spada, C; Riccioni, M E; Rey, J-F; Niv, Y; Delvaux, M; de Franchis, R; Costamagna, G

    2010-03-01

    These recommendations on video capsule endoscopy, an emerging technology with an impact on the practice of endoscopy, were developed by the European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee. The first draft of each section was prepared by one or two members of the writing team, who were selected as experts on the content of that section on the basis of their published work. They used evidence-based methodology, performing MEDLINE and PubMed literature searches to identify relevant clinical studies. Abstracts from scientific meetings were included only if there was no published full paper on a particular topic. If there was disagreement, the first author of the Guideline made the final decision. Recommendations were graded according to the strength of the supporting evidence. The draft guideline was critically reviewed by all authors and submitted to the ESGE councillors for their critical review before approval of the final document. The ESGE Guidelines Committee acknowledges that this document is based on a critical review of the data available at the time of preparation and that further studies may be needed to clarify some aspects. Moreover, this Guideline may be revised as necessary to account for changes in technology, new data, or other aspects of clinical practice. This document should be regarded as supplying recommendations only to gastroenterologists in providing care to their patients. It is not a set of rules and should not be construed as establishing a legal standard of care, or as encouraging, advocating, requiring, or discouraging any particular treatment. These recommendations must be interpreted according to the clinician's knowledge, expertise, and clinical judgment in the management of individual patients and, if necessary, a course of action that varies from recommendations must be undertaken. Georg Thieme Verlag KG Stuttgart. New York.

  6. Achieving real-time capsule endoscopy (CE) video visualization through panoramic imaging

    NASA Astrophysics Data System (ADS)

    Yi, Steven; Xie, Jean; Mui, Peter; Leighton, Jonathan A.

    2013-02-01

    In this paper, we mainly present a novel and real-time capsule endoscopy (CE) video visualization concept based on panoramic imaging. Typical CE videos run about 8 hours and are manually reviewed by physicians to locate diseases such as bleedings and polyps. To date, there is no commercially available tool capable of providing stabilized and processed CE video that is easy to analyze in real time. The burden on physicians' disease finding efforts is thus big. In fact, since the CE camera sensor has a limited forward looking view and low image frame rate (typical 2 frames per second), and captures very close range imaging on the GI tract surface, it is no surprise that traditional visualization method based on tracking and registration often fails to work. This paper presents a novel concept for real-time CE video stabilization and display. Instead of directly working on traditional forward looking FOV (field of view) images, we work on panoramic images to bypass many problems facing traditional imaging modalities. Methods on panoramic image generation based on optical lens principle leading to real-time data visualization will be presented. In addition, non-rigid panoramic image registration methods will be discussed.

  7. Virtual chromoendoscopy can be a useful software tool in capsule endoscopy.

    PubMed

    Duque, Gabriela; Almeida, Nuno; Figueiredo, Pedro; Monsanto, Pedro; Lopes, Sandra; Freire, Paulo; Ferreira, Manuela; Carvalho, Rita; Gouveia, Hermano; Sofia, Carlos

    2012-05-01

    capsule endoscopy (CE) has revolutionized the study of small bowel. One major drawback of this technique is that we cannot interfere with image acquisition process. Therefore, the development of new software tools that could modify the images and increase both detection and diagnosis of small-bowel lesions would be very useful. The Flexible Spectral Imaging Color Enhancement (FICE) that allows for virtual chromoendoscopy is one of these software tools. to evaluate the reproducibility and diagnostic accuracy of the FICE system in CE. this prospective study involved 20 patients. First, four physicians interpreted 150 static FICE images and the overall agreement between them was determined using the Fleiss Kappa Test. Second, two experienced gastroenterologists, blinded to each other results, analyzed the complete 20 video streams. One interpreted conventional capsule videos and the other, the CE-FICE videos at setting 2. All findings were reported, regardless of their clinical value. Non-concordant findings between both interpretations were analyzed by a consensus panel of four gastroenterologists who reached a final result (positive or negative finding). in the first arm of the study the overall concordance between the four gastroenterologists was substantial (0.650). In the second arm, the conventional mode identified 75 findings and the CE-FICE mode 95. The CE-FICE mode did not miss any lesions identified by the conventional mode and allowed the identification of a higher number of angiodysplasias (35 vs 32), and erosions (41 vs. 24). there is reproducibility for the interpretation of CE-FICE images between different observers experienced in conventional CE. The use of virtual chromoendoscopy in CE seems to increase its diagnostic accuracy by highlighting small bowel erosions and angiodysplasias that weren´t identified by the conventional mode.

  8. Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy.

    PubMed

    Spada, Cristiano; Riccioni, Maria E; Familiari, Pietro; Spera, Gianluca; Pirozzi, Giuseppe A; Marchese, Michele; Bizzotto, Alessandra; Ingrosso, Marcello; Costamagna, Guido

    2010-05-01

    Small-bowel contents can hamper the quality of video-capsule endoscopy (VCE). No standardized protocol has been proposed and overnight fasting remains the proposed preparation for VCE. The aim was to evaluate the effects of 2 regimens of bowel preparation on small intestine cleansing, diagnostic yield and capsule transit times. This is a prospective, randomized, blinded, and controlled study. Sixty patients referred for VCE were randomized into 2 groups. Group A ingested 2l of a polyethylene glycol and simethicone solution 16h before VCE. Group B were instructed to consume a fibre-free diet and allowed to consume clear liquids the day before VCE. The small-bowel cleansing was graded as "complete" if the entire wall was assessable, "incomplete" if more than 50% of the wall was visible, and "insufficient" if less than 50% of the wall was visible. In group A, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 42%, 39% and 19% of cases respectively. In group B, a "complete", "incomplete" and "insufficient" small-bowel cleansing was achieved in 43%, 33% and 24% of cases respectively. No significant differences were observed between the two groups, regarding small-bowel cleansing level (p=0.65). No differences were also observed in the diagnostic yield (48.2%, 13.8% and 38% vs 65.5%, 6.9% and 27.6% of positive, suspicious and no findings respectively, in groups A and B [p=0.39]) and small-bowel transit times (mean 288min and 299 min in groups A and B respectively [p=0.70]). The results of the present study do not support the use of 2l of a polyethylene glycol and simethicone solution before VCE. Copyright 2009 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  9. Detection of protruding lesion in wireless capsule endoscopy videos of small intestine

    NASA Astrophysics Data System (ADS)

    Wang, Chengliang; Luo, Zhuo; Liu, Xiaoqi; Bai, Jianying; Liao, Guobin

    2018-02-01

    Wireless capsule endoscopy (WCE) is a developed revolutionary technology with important clinical benefits. But the huge image data brings a heavy burden to the doctors for locating and diagnosing the lesion images. In this paper, a novel and efficient approach is proposed to help clinicians to detect protruding lesion images in small intestine. First, since there are many possible disturbances such as air bubbles and so on in WCE video frames, which add the difficulty of efficient feature extraction, the color-saliency region detection (CSD) method is developed for extracting the potentially saliency region of interest (SROI). Second, a novel color channels modelling of local binary pattern operator (CCLBP) is proposed to describe WCE images, which combines grayscale and color angle. The CCLBP feature is more robust to variation of illumination and more discriminative for classification. Moreover, support vector machine (SVM) classifier with CCLBP feature is utilized to detect protruding lesion images. Experimental results on real WCE images demonstrate that proposed method has higher accuracy on protruding lesion detection than some art-of-state methods.

  10. Outcome in obscure gastrointestinal bleeding after capsule endoscopy.

    PubMed

    Cañas-Ventura, Alex; Márquez, Lucia; Bessa, Xavier; Dedeu, Josep Maria; Puigvehí, Marc; Delgado-Aros, Sílvia; Ibáñez, Ines Ana; Seoane, Agustin; Barranco, Luis; Bory, Felipe; Andreu, Montserrat; González-Suárez, Begoña

    2013-11-16

    To investigate the clinical impact of capsule endoscopy (CE) after an obscure gastrointestinal bleeding (OGIB) episode, focusing on diagnostic work-up, follow-up and predictive factors of rebleeding. Patients who were referred to Hospital del Mar (Barcelona, Spain) between 2007 and 2009 for OGIB who underwent a CE were retrospectively analyzed. Demographic data, current treatment with non-steroid anti-inflammtory drugs or anticoagulant drugs, hemoglobin levels, transfusion requirements, previous diagnostic tests for the bleeding episode, as well as CE findings (significant or non-significant), work-up and patient outcomes were analyzed from electronic charts. Variables were compared by χ (2) analysis and Student t test. Risk factors of rebleeding were assessed by Log-rank test, Kaplan-Meier curves and Cox regression model. There were 105 patients [45.7% women, median age of 72 years old (interquartile range 56-79)] and a median follow-up of 326 d (interquartile range 123-641) included in this study. The overall diagnostic yield of CE was 58.1% (55.2% and 63.2%, for patients with occult OGIB and overt OGIB, respectively). In 73 patients (69.5%), OGIB was resolved. Multivariate analysis showed that hemoglobin levels lower than 8 g/dL at diagnosis [hazard ratios (HR) = 2.7, 95%CI: 1.9-6.3], patients aged 70 years and above (HR = 2.1, 95%CI: 1.2-6.1) and significant findings in CE (HR = 2.4, 95%CI: 1.1-5.8) were independent predictors of rebleeding. One third of the patients presented with rebleeding after CE; risk factors were hemoglobin levels < 8 g/dL, age ≥ 70 years or the presence of significant lesions.

  11. Wireless communication link for capsule endoscope at 600 MHz.

    PubMed

    Khaleghi, A; Balasingham, I

    2015-01-01

    Simulation of a wireless communication link for a capsule endoscopy is presented for monitoring of small intestine in humans. The realized communication link includes the transmitting capsule antenna, the outside body receiving antenna and the model of the human body. The capsule antenna is designed for operating at the frequency band of 600 MHz with an impedance bandwidth of 10 MHz and omnidirectional radiation pattern. The quality of the communication link is improved by using directive antenna outside body inside matching layer for electromagnetic wave tuning to the body. The outside body antenna has circular polarization that guaranteeing the communication link for different orientations of the capsule inside intestine. It is shown that the path loss for the capsule in 60 mm from the abdomen surface varies between 37-47 dB in relation to the antenna orientation. This link can establish high data rate wireless communications for capsule endoscopy.

  12. Tumor recognition in wireless capsule endoscopy images using textural features and SVM-based feature selection.

    PubMed

    Li, Baopu; Meng, Max Q-H

    2012-05-01

    Tumor in digestive tract is a common disease and wireless capsule endoscopy (WCE) is a relatively new technology to examine diseases for digestive tract especially for small intestine. This paper addresses the problem of automatic recognition of tumor for WCE images. Candidate color texture feature that integrates uniform local binary pattern and wavelet is proposed to characterize WCE images. The proposed features are invariant to illumination change and describe multiresolution characteristics of WCE images. Two feature selection approaches based on support vector machine, sequential forward floating selection and recursive feature elimination, are further employed to refine the proposed features for improving the detection accuracy. Extensive experiments validate that the proposed computer-aided diagnosis system achieves a promising tumor recognition accuracy of 92.4% in WCE images on our collected data.

  13. Modular "plug-and-play" capsules for multi-capsule environment in the gastrointestinal tract.

    PubMed

    Phee, S J; Ting, E K; Lin, L; Huynh, V A; Kencana, A P; Wong, K J; Tan, S L

    2009-01-01

    The invention of wireless capsule endoscopy has opened new ways of diagnosing and treating diseases in the gastrointestinal tract. Current wireless capsules can perform simple operations such as imaging and data collection (like temperature, pressure, and pH) in the gastrointestinal tract. Researchers are now focusing on adding more sophisticated functions such as drug delivery, surgical clips/tags deployment, and tissue samples collection. The finite on-board power on these capsules is one of the factors that limits the functionalities of these wireless capsules. Thus multiple application-specific capsules would be needed to complete an endoscopic operation. This would give rise to a multi-capsule environment. Having a modular "plug-and-play" capsule design would facilitate doctors in configuring multiple application-specific capsules, e.g. tagging capsule, for use in the gastrointestinal tract. This multi-capsule environment also has the advantage of reducing power consumption through asymmetric multi-hop communication.

  14. Engineering Micromechanical Systems for the Next Generation Wireless Capsule Endoscopy

    PubMed Central

    Woods, Stephen; Constandinou, Timothy

    2015-01-01

    Wireless capsule endoscopy (WCE) enables the detection and diagnosis of inflammatory bowel diseases such as Crohn's disease and ulcerative colitis. However treatment of these pathologies can only be achieved through conventional means. This paper describes the next generation WCE with increased functionality to enable targeted drug delivery in the small intestinal tract. A prototype microrobot fabricated in Nylon 6 is presented which is capable of resisting peristaltic pressure through the deployment of an integrated holding mechanism and delivering targeted therapy. The holding action is achieved by extending an “anchor” spanning a 60.4 mm circumference, for an 11.0 mm diameter WCE. This function is achieved by a mechanism that occupies only 347.0 mm3 volume, including mechanics and actuator. A micropositioning mechanism is described which utilises a single micromotor to radially position and then deploy a needle 1.5 mm outside the microrobot's body to deliver a 1 mL dose of medication to a targeted site. An analysis of the mechanics required to drive the holding mechanism is presented and an overview of microactuators and the state of the art in WCE is discussed. It is envisaged that this novel functionality will empower the next generation of WCE to help diagnose and treat pathologies of the GI tract. PMID:26258143

  15. A simplified ingestion procedure for esophageal capsule endoscopy: initial evaluation in healthy volunteers.

    PubMed

    Gralnek, I M; Rabinovitz, R; Afik, D; Eliakim, R

    2006-09-01

    Initial studies on esophageal capsule endoscopy (PillCam ESO) reported excellent sensitivity and specificity, but these were followed by mixed results in several subsequent studies, probably due to deviations from the recommended ingestion protocol and the inconvenience of capsule ingestion in the supine position. The aim of this study was therefore to test a simplified ingestion procedure (SIP) for PillCam ESO. Using a cross-over study design, the SIP was prospectively compared with the original ingestion procedure for PillCam ESO in 24 healthy volunteers (15 men, nine women; mean age 44, range 27 - 70) and evaluated for: bubbles/saliva interference at the Z-line, Z-line circumferential visualization (quadrants), and convenience and ease of the ingestion procedure. All Rapid 4 videos were reviewed in a randomized manner and read by an experienced PillCam ESO reader blinded to the ingestion procedure used. It was found that the SIP significantly improved visualization in comparison with the original ingestion procedure, with less interference due to bubbles/saliva observed at the gastroesophageal junction ( P = 0.002) and improved visualization of the Z-line ( P = 0.025). Although the esophageal transit time was significantly faster with the SIP (3 : 45 min vs. 0 : 38 min; P = 0.0001), there were no differences in the number of Z-line frames/images captured. This new, simplified ingestion procedure for PillCam ESO provides significantly improved visualization of the Z-line in healthy volunteers. The overall test characteristics of PillCam ESO using SIP should be tested in patients with esophageal disease.

  16. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device.

    PubMed

    Holden, Jeremy P; Dureja, Parul; Pfau, Patrick R; Schwartz, Darren C; Reichelderfer, Mark; Judd, Robert H; Danko, Istvan; Iyer, Lalitha V; Gopal, Deepak V

    2007-05-01

    Capsule endoscopy performed via the traditional peroral route is technically challenging in patients with dysphagia, gastroparesis, and/or abnormal upper-GI (UGI) anatomy. To describe the indications and outcomes of cases in which the AdvanCE capsule endoscope delivery device, which has recently been cleared by the Food and Drug Administration, was used. Retrospective, descriptive, case series. Tertiary care, university hospital. We report a case series of 16 consecutive patients in whom the AdvanCE delivery device was used. The study period was May 2005 through July 2006. Endoscopic delivery of the video capsule to the proximal small bowel by using the AdvanCE delivery device. Indications, technique, and completeness of small bowel imaging in patients who underwent endoscopic video capsule delivery. The AdvanCE delivery device was used in 16 patients ranging in age from 3 to 74 years. The primary indications for endoscopic delivery included inability to swallow the capsule (10), altered UGI anatomy (4), and gastroparesis (2). Of the 4 patients with altered UGI anatomy, 3 had dual intestinal loop anatomy (ie, Bilroth-II procedure, Whipple surgery, Roux-en-Y gastric bypass) and 1 had a failed Nissen fundoplication. In all cases, the capsule was easily deployed without complication, and complete small intestinal imaging was achieved. Small patient size. Endoscopic placement of the Given PillCam by use of the AdvanCE delivery device was safe and easily performed in patients for whom capsule endoscopy would otherwise have been contraindicated or technically challenging.

  17. KID Project: an internet-based digital video atlas of capsule endoscopy for research purposes

    PubMed Central

    Koulaouzidis, Anastasios; Iakovidis, Dimitris K.; Yung, Diana E.; Rondonotti, Emanuele; Kopylov, Uri; Plevris, John N.; Toth, Ervin; Eliakim, Abraham; Wurm Johansson, Gabrielle; Marlicz, Wojciech; Mavrogenis, Georgios; Nemeth, Artur; Thorlacius, Henrik; Tontini, Gian Eugenio

    2017-01-01

    Background and aims  Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE. Methods  Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers. Results  The MLA performed best in measuring lymphangiectasias with a JI of 81 ± 6 %. The other lesion types were: angioectasias (JI 64 ± 11 %), aphthae (JI 64 ± 8 %), chylous cysts (JI 70 ± 14 %), polypoid lesions (JI 75 ± 21 %), and ulcers (JI 56 ± 9 %). Conclusion  MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential. PMID:28580415

  18. Bleeding detection in wireless capsule endoscopy using adaptive colour histogram model and support vector classification

    NASA Astrophysics Data System (ADS)

    Mackiewicz, Michal W.; Fisher, Mark; Jamieson, Crawford

    2008-03-01

    Wireless Capsule Endoscopy (WCE) is a colour imaging technology that enables detailed examination of the interior of the gastrointestinal tract. A typical WCE examination takes ~ 8 hours and captures ~ 40,000 useful images. After the examination, the images are viewed as a video sequence, which generally takes a clinician over an hour to analyse. The manufacturers of the WCE provide certain automatic image analysis functions e.g. Given Imaging offers in their Rapid Reader software: The Suspected Blood Indicator (SBI), which is designed to report the location in the video of areas of active bleeding. However, this tool has been reported to have insufficient specificity and sensitivity. Therefore it does not free the specialist from reviewing the entire footage and was suggested only to be used as a fast screening tool. In this paper we propose a method of bleeding detection that uses in its first stage Hue-Saturation-Intensity colour histograms to track a moving background and bleeding colour distributions over time. Such an approach addresses the problem caused by drastic changes in blood colour distribution that occur when it is altered by gastrointestinal fluids and allow detection of other red lesions, which although are usually "less red" than fresh bleeding, they can still be detected when the difference between their colour distributions and the background is large enough. In the second stage of our method, we analyse all candidate blood frames, by extracting colour (HSI) and texture (LBP) features from the suspicious image regions (obtained in the first stage) and their neighbourhoods and classifying them using Support Vector Classifier into Bleeding, Lesion and Normal classes. We show that our algorithm compares favourably with the SBI on the test set of 84 full length videos.

  19. Capsule endoscopy in the evaluation and management of inflammatory bowel disease: a future perspective.

    PubMed

    Saruta, Masayuki; Papadakis, Konstantinos A

    2009-01-01

    Wireless capsule endoscopy (WCE) has emerged as an important diagnostic tool for the evaluation of patients with suspected small intestinal (SI) disease, including obscure gastrointestinal bleeding, Crohn's disease (CD), malabsorptive disorders and SI tumors. Since a great number of patients with CD have small-bowel (SB) involvement, it is important for newly diagnosed patients to undergo an evaluation of the SB, which has traditionally been performed using a radiographic study such as a SB follow-through. The greatest utility of WCE in the evaluation of SB CD has been observed in cases of suspected CD, where the initial evaluation with upper and lower endoscopy as well as traditional radiographic techniques have failed to establish the diagnosis. WCE can detect SB involvement in CD, particularly early lesions that can be overlooked by traditional radiological studies. The sensitivity of diagnosing SB CD by WCE is superior to other endoscopic or radiological methods such as push enteroscopy, computed tomography or magnetic resonance enteroclysis. The utility of WCE in patients with known CD, indeterminate colitis and a select group of patients with ulcerative colitis can help to better define the diagnosis and extent of the disease, and assist in the management of patients with persistent symptoms. A disadvantage of WCE is that the device may be retained in a strictured area of the SB, which may often be present in patients with CD, in addition to a lower specificity. WCE may replace classical studies and become the gold standard for diagnosing SB involvement in patients with suspected, or known CD, in the absence of strictures and fistulae.

  20. Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract

    NASA Astrophysics Data System (ADS)

    Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay

    2011-03-01

    Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.

  1. Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.

    PubMed

    Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio

    2011-08-02

    Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.

  2. Controlling the Display of Capsule Endoscopy Video for Diagnostic Assistance

    NASA Astrophysics Data System (ADS)

    Vu, Hai; Echigo, Tomio; Sagawa, Ryusuke; Yagi, Keiko; Shiba, Masatsugu; Higuchi, Kazuhide; Arakawa, Tetsuo; Yagi, Yasushi

    Interpretations by physicians of capsule endoscopy image sequences captured over periods of 7-8 hours usually require 45 to 120 minutes of extreme concentration. This paper describes a novel method to reduce diagnostic time by automatically controlling the display frame rate. Unlike existing techniques, this method displays original images with no skipping of frames. The sequence can be played at a high frame rate in stable regions to save time. Then, in regions with rough changes, the speed is decreased to more conveniently ascertain suspicious findings. To realize such a system, cue information about the disparity of consecutive frames, including color similarity and motion displacements is extracted. A decision tree utilizes these features to classify the states of the image acquisitions. For each classified state, the delay time between frames is calculated by parametric functions. A scheme selecting the optimal parameters set determined from assessments by physicians is deployed. Experiments involved clinical evaluations to investigate the effectiveness of this method compared to a standard-view using an existing system. Results from logged action based analysis show that compared with an existing system the proposed method reduced diagnostic time to around 32.5 ± minutes per full sequence while the number of abnormalities found was similar. As well, physicians needed less effort because of the systems efficient operability. The results of the evaluations should convince physicians that they can safely use this method and obtain reduced diagnostic times.

  3. Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn’s disease patients

    PubMed Central

    Papamichael, Konstantinos; Karatzas, Pantelis; Theodoropoulos, Ioannis; Kyriakos, Nikos; Archavlis, Emmanuel; Mantzaris, Gerasimos J.

    2015-01-01

    Background Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn’s disease (CD). Methods This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. Results Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. Conclusion Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients. PMID:26423317

  4. Gastrointestinal endoscopy in pregnancy

    PubMed Central

    Savas, Nurten

    2014-01-01

    Gastrointestinal endoscopy has a major diagnostic and therapeutic role in most gastrointestinal disorders; however, limited information is available about clinical efficacy and safety in pregnant patients. The major risks of endoscopy during pregnancy include potential harm to the fetus because of hypoxia, premature labor, trauma and teratogenesis. In some cases, endoscopic procedures may be postponed until after delivery. When emergency or urgent indications are present, endoscopic procedures may be considered with some precautions. United States Food and Drug Administration category B drugs may be used in low doses. Endoscopic procedures during pregnancy may include upper gastrointestinal endoscopy, percutaneous endoscopic gastrostomy, sigmoidoscopy, colonoscopy, enteroscopy of the small bowel or video capsule endoscopy, endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography. All gastrointestinal endoscopic procedures in pregnant patients should be performed in hospitals by expert endoscopists and an obstetrician should be informed about all endoscopic procedures. The endoscopy and flexible sigmoidoscopy may be safe for the fetus and pregnant patient, and may be performed during pregnancy when strong indications are present. Colonoscopy for pregnant patients may be considered for strong indications during the second trimester. Although therapeutic endoscopic retrograde cholangiopancreatography may be considered during pregnancy, this procedure should be performed only for strong indications and attempts should be made to minimize radiation exposure. PMID:25386072

  5. Aspiration of capsule endoscope and successful bronchoscopic extraction.

    PubMed

    Girdhar, Ankur; Usman, Faisal; Bajwa, Abubakr

    2012-10-01

    Capsule endoscopy is a novel tool for the diagnosis of small intestinal disorders. Recently, a new complication of the procedure in the form of the capsule's aspiration into the lungs has been reported. The aspiration of capsule endoscope can lead to a variety of complications including respiratory failure. A low threshold to suspect this complication and urgent bronchoscopic extraction in appropriate patients can prevent serious sequelae.

  6. Validation of the Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score): a multicenter prospective study.

    PubMed

    Niv, Y; Ilani, S; Levi, Z; Hershkowitz, M; Niv, E; Fireman, Z; O'Donnel, S; O'Morain, C; Eliakim, R; Scapa, E; Kalantzis, N; Kalantzis, C; Apostolopoulos, P; Gal, E

    2012-01-01

    The Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score) was devised to measure mucosal disease activity using video capsule endoscopy (VCE). The aim of the current study was to prospectively validate the use of the scoring system in daily practice. This was a multicenter, double-blind, prospective, controlled study of VCE videos from 62 consecutive patients with isolated small-bowel Crohn's disease. The CECDAI was designed to evaluate three main parameters of Crohn's disease: inflammation (A), extent of disease (B), and stricture (C), in both the proximal and distal segments of the small bowel. The final score was calculated by adding the two segmental scores: CECDAI = ([A1 × B1] + C1) + ([A2 × B2] + C2). Each examiner in every site interpreted 6 - 10 videos and calculated the CECDAI. The de-identified CD-ROMs were then coded and sent to the principal investigator for CECDAI calculation. The cecum was reached in 72 % and 86 % of examinations, and proximal small-bowel involvement was found in 56 % and 62 % of the patients, according to the site investigators and principal investigator, respectively. Significant correlation was demonstrated between the calculation of the CECDAI by the individual site investigators and that performed by the principal investigator. Overall correlation between endoscopists from the different study centers was good, with r = 0.767 (range 0.717 - 0.985; Kappa 0.66; P < 0.001). There was no correlation between the CECDAI and the Crohn's Disease Activity Index or the Inflammatory Bowel Disease Quality of Life Questionnaire or any of their components. A new scoring system of mucosal injury in Crohn's disease of the small intestine, the CECDAI, was validated. Its use in controlled trials and/or regular follow-up of these patients is advocated. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Small-bowel mucosal healing assessment by capsule endoscopy as a predictor of long-term clinical remission in patients with Crohn's disease: a systematic review and meta-analysis.

    PubMed

    Niv, Yaron

    2017-07-01

    Capsule endoscopy (CE) may be used for the evaluation and follow-up of patients with Crohn's disease. CE scores correspond to the degree of mucosal inflammation, a major therapeutic target. The aim of this meta-analysis and systematic review was to determine whether mucosal healing assessment by CE may serve as a predictor of clinical remission in patients with Crohn's disease. To identify observational or controlled English-language full-text studies assessing mucosal healing by CE in patients with Crohn's disease up to 30 September 2016, we searched PubMed, Embase, Central, Medline, and Scopus using the key words 'mucosal healing' and 'capsule endoscopy'. A meta-analysis was carried out using 'Comprehensive meta-analysis' software. Pooled odds ratios and 95% confidence intervals were calculated. Five observational studies including 142 patients from five countries fulfilled the inclusion criteria. No publication bias was found by funnel plot. The mucosal healing CE score was found to be significantly associated with improved outcome after a follow-up of 12 weeks to 24 months, with an odds ratio of 11.06 (95% confidence interval: 3.74-32.73, P<0.001). The degree of heterogeneity among the studies was small (Q=2.014, d.f.[Q]=3, P=0.569 and I=0). Endoscopy scores may play a role in the long-term prognostic evaluation of patients with Crohn's disease. Our results may be accepted as proof of concept, but larger studies are needed to corroborate these findings.

  8. Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy.

    PubMed

    Khan, Umair; Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh

    2018-01-01

    In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution.

  9. Bronchial Aspiration of Capsule Endoscope.

    PubMed

    Buscot, Matthieu; Leroy, Sylvie; Pradelli, Johanna; Chaabane, Nouha; Hebuterne, Xavier; Marquette, Charles-Hugo; Filippi, Jerôme

    2017-01-01

    Capsule endoscope aspiration is an increasingly reported complication, potentially responsible for respiratory distress and asphyxia. This adverse event is primarily managed by rigid bronchoscopy when spontaneous expulsion does not occur. This complication is all the more detrimental to patients as it can delay or jeopardize further digestive exploration. We report direct repositioning of the capsule in the stomach at the same time as bronchoscopy, thus making second-line gastrointestinal endoscopy needless. © 2017 S. Karger AG, Basel.

  10. Microultrasound characterisation of ex vivo porcine tissue for ultrasound capsule endoscopy

    NASA Astrophysics Data System (ADS)

    Lay, H. S.; Cox, B. F.; Sunoqrot, M.; Démoré, C. E. M.; Näthke, I.; Gomez, T.; Cochran, S.

    2017-01-01

    Gastrointestinal (GI) disease development and progression is often characterised by cellular and tissue architectural changes within the mucosa and sub-mucosa layers. Current clinical capsule endoscopy and other approaches are heavily reliant on optical techniques which cannot detect disease progression below the surface layer of the tissue. To enhance the ability of clinicians to detect cellular changes earlier and more confidently, both quantitative and qualitative microultrasound (μUS) techniques are investigated in healthy ex vivo porcine GI tissue. This work is based on the use of single-element, focussed μUS transducers made with micromoulded piezocomposite operating at around 48 MHz. To explore the possibility that μUS can detect Crohn’s disease and other inflammatory bowel diseases, ex vivo porcine small bowel tissue samples were cannulised and perfused with phosphate-buffered saline followed by various dilutions of polystyrene microspheres. Comparison with fluorescent imaging showed that the microspheres had infiltrated the microvasculature of the samples and that μUS was able to successfully detect this as a mimic of inflammation. Samples without microspheres were analysed using quantitative ultrasound to assess mechanical properties. Attenuation coefficients of 1.78 ± 0.66 dB/mm and 1.92 ± 0.77 dB/mm were obtained from reference samples which were surgically separated from the muscle layer. Six intact samples were segmented using a software algorithm and the acoustic impedance, Z, for varying tissue thicknesses, and backscattering coefficient, BSC, were calculated using the reference attenuation values and tabulated.

  11. Remote magnetic manipulation of a wireless capsule endoscope in the esophagus and stomach of humans (with videos).

    PubMed

    Swain, Paul; Toor, Arifa; Volke, Frank; Keller, Jutta; Gerber, Jeremy; Rabinovitz, Elisha; Rothstein, Richard I

    2010-06-01

    Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. To test a new capsule-manipulation system. University hospital. A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a microg of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Magnetic force varies with the fourth power of distance. This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  12. Precision of EM Simulation Based Wireless Location Estimation in Multi-Sensor Capsule Endoscopy

    PubMed Central

    Ye, Yunxing; Aisha, Ain-Ul; Swar, Pranay; Pahlavan, Kaveh

    2018-01-01

    In this paper, we compute and examine two-way localization limits for an RF endoscopy pill as it passes through an individuals gastrointestinal (GI) tract. We obtain finite-difference time-domain and finite element method-based simulation results position assessment employing time of arrival (TOA). By means of a 3-D human body representation from a full-wave simulation software and lognormal models for TOA propagation from implant organs to body surface, we calculate bounds on location estimators in three digestive organs: stomach, small intestine, and large intestine. We present an investigation of the causes influencing localization precision, consisting of a range of organ properties; peripheral sensor array arrangements, number of pills in cooperation, and the random variations in transmit power of sensor nodes. We also perform a localization precision investigation for the situation where the transmission signal of the antenna is arbitrary with a known probability distribution. The computational solver outcome shows that the number of receiver antennas on the exterior of the body has higher impact on the precision of the location than the amount of capsules in collaboration within the GI region. The large intestine is influenced the most by the transmitter power probability distribution. PMID:29651364

  13. A Simple Evaluation Tool (ET-CET) Indicates Increase of Diagnostic Skills From Small Bowel Capsule Endoscopy Training Courses: A Prospective Observational European Multicenter Study.

    PubMed

    Albert, J G; Humbla, O; McAlindon, M E; Davison, C; Seitz, U; Fraser, C; Hagenmüller, F; Noetzel, E; Spada, C; Riccioni, M E; Barnert, J; Filmann, N; Keuchel, M

    2015-10-01

    Small bowel capsule endoscopy (SBCE) has become a first line diagnostic tool. Several training courses with a similar format have been established in Europe; however, data on learning curve and training in SBCE remain sparse.Between 2008 and 2011, different basic SBCE training courses were organized internationally in UK (n = 2), Italy (n = 2), Germany (n = 2), Finland (n = 1), and nationally in Germany (n = 10), applying similar 8-hour curricula with 50% lectures and 50% hands-on training. The Given PillCam System was used in 12 courses, the Olympus EndoCapsule system in 5, respectively. A simple evaluation tool for capsule endoscopy training (ET-CET) was developed using 10 short SBCE videos including relevant lesions and normal or irrelevant findings. For each video, delegates were required to record a diagnosis (achievable total score from 0 to 10) and the clinical relevance (achievable total score 0 to 10). ET-CET was performed at baseline before the course and repeated, with videos in altered order, after the course.Two hundred ninety-four delegates (79.3% physicians, 16.3% nurses, 4.4% others) were included for baseline analysis, 268 completed the final evaluation. Forty percent had no previous experience in SBCE, 33% had performed 10 or less procedures. Median scores for correct diagnosis improved from 4.0 (IQR 3) to 7.0 (IQR 3) during the courses (P < 0.001, Wilcoxon), and for correct classification of relevance of the lesions from 5.0 (IQR 3) to 7.0 (IQR 3) (P < 0.001), respectively. Improvement was not dependent on experience, profession, SBCE system, or course setting. Previous experience in SBCE was associated with higher baseline scores for correct diagnosis (P < 0.001; Kruskal-Wallis). Additionally, independent nonparametric partial correlation with experience in gastroscopy (rho 0.33) and colonoscopy (rho 0.27) was observed (P < 0.001).A simple ET-CET demonstrated significant improvement of diagnostic skills on

  14. Wireless fluorescence capsule for endoscopy using single photon-based detection

    NASA Astrophysics Data System (ADS)

    Al-Rawhani, Mohammed A.; Beeley, James; Cumming, David R. S.

    2015-12-01

    Fluorescence Imaging (FI) is a powerful technique in biological science and clinical medicine. Current FI devices that are used either for in-vivo or in-vitro studies are expensive, bulky and consume substantial power, confining the technique to laboratories and hospital examination rooms. Here we present a miniaturised wireless fluorescence endoscope capsule with low power consumption that will pave the way for future FI systems and applications. With enhanced sensitivity compared to existing technology we have demonstrated that the capsule can be successfully used to image tissue autofluorescence and targeted fluorescence via fluorophore labelling of tissues. The capsule incorporates a state-of-the-art complementary metal oxide semiconductor single photon avalanche detector imaging array, miniaturised optical isolation, wireless technology and low power design. When in use the capsule consumes only 30.9 mW, and deploys very low-level 468 nm illumination. The device has the potential to replace highly power-hungry intrusive optical fibre based endoscopes and to extend the range of clinical examination below the duodenum. To demonstrate the performance of our capsule, we imaged fluorescence phantoms incorporating principal tissue fluorophores (flavins) and absorbers (haemoglobin). We also demonstrated the utility of marker identification by imaging a 20 μM fluorescein isothiocyanate (FITC) labelling solution on mammalian tissue.

  15. Patency© and agile© capsules

    PubMed Central

    Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M

    2008-01-01

    Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278

  16. Video Capsule Endoscopy: A Tool for the Assessment of Small Bowel Transit Time.

    PubMed

    Hejazi, Reza A; Bashashati, Mohammad; Saadi, Mohammed; Mulla, Zuber D; Sarosiek, Irene; McCallum, Richard W; Zuckerman, Marc J

    2016-01-01

    Video capsule endoscopy (VCE) is a procedure that uses a wireless camera to take pictures of the gastrointestinal (GI) tract. A wireless motility capsule (WMC) of a similar size has been developed, which measures pH, pressure, and temperature and can be used to assess regional and total GI transit times. VCE could also potentially be used as a tool for measuring small bowel transit time (SBTT). This study was designed to obtain SBTT from VCE and compare it with historical data generated by WMC. Gastric transit time (GTT) was also measured. Patients were included if the indication for VCE was either iron deficiency anemia (IDA) or overt obscure GI bleed (OOGIB), and they did not have any known motility disorder. Results from VCE were also compared in diabetic vs. non-diabetic patients. There were a total of 147 VCE studies performed, including 42 for OOGIB and 105 for IDA. Median GTT and SBTT were 0.3 and 3.6 h, respectively. The overall median GTT and SBTT were 0.3 and 3.6 h, respectively, in the IDA group compared with 0.3 and 3.4 h in the OOGIB group. When compared with WMC, the GTT and SBTT were significantly faster in both groups (GTT: 3.6 h and SBTT: 4.6 h). The median GTT and SBTT were not significantly different in diabetics vs. non-diabetics [GTT: 17.5 vs. 18.0 min (P = 0.86) and SBTT: 3.9 h (237 min) vs. 3.8 h (230 min), respectively (P = 0.90)]. SBTT as measured using VCE is not significantly different in OOGIB compared with IDA. Both GTT and SBTT are significantly faster as assessed by VCE, which is initiated in the fasting state, compared with WMC measurement, which is initiated after a standard meal. In summary, VCE could potentially be used for measuring SBTT in the fasting state.

  17. Progress in digestive endoscopy: Flexible Spectral Imaging Colour Enhancement (FICE)-technical review.

    PubMed

    Negreanu, L; Preda, C M; Ionescu, D; Ferechide, D

    2015-01-01

    Background. A substantial advance in digestive endoscopy that has been made during the last decade is represented by digital chromoendoscopy, which was developed as a quicker and sometimes better alternative to the gold standard of dye spraying. Fujifilm developed a virtual coloration technique called Flexible spectral Imaging Color Enhancement (FICE). FICE provides a better detection of lesions of "minimal" esophagitis, of dysplasia in Barrett's esophagus and of squamous cell esophageal cancer. The use of FICE resulted in an improvement in the visualization of the early gastric cancer, being less invasive, and time consuming than the classic dye methods. Current evidence does not support FICE for screening purposes in colon cancer but it definitely improves characterization of colonic lesions. Its use in inflammatory bowel disease is still controversial and in video capsule endoscopy is considered a substantial progress. Conclusions. The use of FICE endoscopy in routine clinical practice can increase the diagnostic yield and can provide a better characterization of lesions. Future studies to validate its use, the good choice of channels, and the "perfect indications" and to provide common definitions and classifications are necessary.

  18. Addition of simethicone improves small bowel capsule endoscopy visualisation quality.

    PubMed

    Krijbolder, M S; Grooteman, K V; Bogers, S K; de Jong, D J

    2018-01-01

    Small bowel capsule endoscopy (SBCE) is an important diagnostic tool for small-bowel diseases but its quality may be hampered by intraluminal gas. This study evaluated the added value of the anti-foaming agent, simethicone, to a bowel preparation with polyethylene glycol (PEG) on the quality of small bowel visualisation and its use in the Netherlands. This was a retrospective, single-blind, cohort study. Patients in the PEG group only received PEG prior to SBCE. Patients in the PEG-S group ingested additional simethicone. Two investigators assessed the quality of small-bowel visualisation using a four-point scale for 'intraluminal gas' and 'faecal contamination'. By means of a survey, the use of anti-foaming agents was assessed in a random sample of 16 Dutch hospitals performing SBCE. The quality of small bowel visualisation in the PEG group (n = 33) was significantly more limited by intraluminal gas when compared with the PEG-S group (n = 31): proximal segment 83.3% in PEG group vs. 18.5% in PEG-S group (p < 0.01), distal segment 66.7% vs. 18.5% respectively (p < 0.01). No difference was observed in the amount of faecal contamination (proximal segment 80.0% PEG vs. 59.3% PEG-S, p = 0.2; distal segment 90.0% PEG vs. 85.2% PEG-S, p = 0.7), mean small bowel transit times (4.0 PEG vs. 3.9 hours PEG-S, p = 0.7) and diagnostic yield (43.3% PEG vs. 22.2% PEG-S, p = 0.16). Frequency of anti-foaming agent use in the Netherlands was low (3/16, 18.8%). Simethicone is of added value to a PEG bowel preparation in improving the quality of visualisation of the small bowel by reducing intraluminal gas. At present, the use of anti-foaming agents in SBCE preparation is not standard practice in the Netherlands.

  19. Magnetic resonance enterography or video capsule endoscopy – what do Crohn’s disease patients prefer?

    PubMed Central

    Lahat, Adi; Kopylov, Uri; Amitai, Marianne M; Neuman, Sandra; Levhar, Nina; Yablecovitch, Doron; Avidan, Benjamin; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Eliakim, Rami

    2016-01-01

    Background Despite differences in the information obtained by capsule endoscopy (CE) and magnetic resonance enterography (MRE), one of these modalities is usually needed when evaluating disease activity. There are no data on patients’ preference that would help guide the choice between these two modalities in these instances. Aim To compare patients’ tolerance and preference to MRE versus CE. Patients and methods Patients with known small bowel Crohn’s disease (CD) in clinical remission (Crohn’s disease activity index [CDAI] <150) or with mild symptoms (CDAI <220) were prospectively recruited. All patients underwent MRE followed by CE. Patients were asked to fill out a questionnaire addressing specific points regarding inconvenience during the preparation for the procedures, the procedures, and postprocedures. Side effects and procedure preference were addressed. Questionnaires were included for analysis only when more than 95% of the items were addressed. Results Fifty-six patients fulfilled inclusion criteria. Pre-exam discomfort, during-exam discomfort, nausea, vomiting, bloating, and abdominal pain were all significantly more prominent in MRE as compared to CE (P<0.0001, P<0.0001, P<0.0001, P=0.009, P=0.0002, P<0.0001, respectively). MRE was perceived as a more difficult procedure (P<0.0001). Furthermore, MRE was associated with a specific adverse event – claustrophobia. Seventy-eight percent of patients (44 patients) preferred to repeat CE as compared to 22% (P<0.0001) who preferred MRE. Conclusion CE was better tolerated by CD patients compared to MRE and was preferred by 78% of patients. The superior tolerability of CE should be considered along with the diagnostic features, and more data sought when choosing between these two modalities for CD patients for long-term follow-up. PMID:27354774

  20. Capsule endoscopy for the detection of oesophageal mucosal disorders: a comparison of two different ingestion protocols.

    PubMed

    De Jonge, Pieter J F; Van Eijck, Brechje C; Geldof, Han; Bekkering, Frank C; Essink-Bot, Marie-Louise; Polinder, Suzanne; Kuipers, Ernst J; Siersema, Peter D

    2008-01-01

    To assess the accuracy of a new ingestion protocol for capsule endoscopy (CE) in evaluating patients with gastro-oesophageal reflux disease (GORD). Oesophago-gastroduodenoscopy (OGD) was performed 1 week prior to CE. The first 28 subjects swallowed the capsule following the original ingestion protocol (OIP) and the subsequent 30 subjects following a simplified ingestion protocol (SIP). CE videos were reviewed by two independent investigators who were blinded to the OGD findings. Of 48 patients included, 24 were diagnosed with reflux oesophagitis (67% male, mean age 49.5+/-13 years) and 24 with Barrett oesophagus (BO) (88% male, 55.6+/-10 years) by OGD. In addition, 10 asymptomatic healthy controls (50% male, 45.8+/-7.1 years) were included. Oesophageal transit time was faster in patients using the SIP compared to the OIP (126+/-26 s versus 214+/-33; p=0.04). Complete evaluation of the Z-line was possible in 19/28 (68%) of the OIPs compared to 28/30 (93%) of the SIPs (p=0.04). Sensitivity for detecting any oesophageal abnormality was higher in the SIP group than in the OIP group (97% versus 89%; p=0.11). Overall, CE detected oesophagitis in 22/24 patients (sensitivity, 92%; specificity, 88%) and BO in 23/24 patients (sensitivity, 96%; specificity, 91%). Furthermore, 41/44 (93%) preferred CE over OGD and experienced less discomfort and pain during CE. CE is an accurate method for detecting mucosal oesophageal abnormalities. The new ingestion protocol improves the visualization of the Z-line, which is likely to increase the diagnostic yield of CE.

  1. A clinically viable capsule endoscopy video analysis platform for automatic bleeding detection

    NASA Astrophysics Data System (ADS)

    Yi, Steven; Jiao, Heng; Xie, Jean; Mui, Peter; Leighton, Jonathan A.; Pasha, Shabana; Rentz, Lauri; Abedi, Mahmood

    2013-02-01

    In this paper, we present a novel and clinically valuable software platform for automatic bleeding detection on gastrointestinal (GI) tract from Capsule Endoscopy (CE) videos. Typical CE videos for GI tract run about 8 hours and are manually reviewed by physicians to locate diseases such as bleedings and polyps. As a result, the process is time consuming and is prone to disease miss-finding. While researchers have made efforts to automate this process, however, no clinically acceptable software is available on the marketplace today. Working with our collaborators, we have developed a clinically viable software platform called GISentinel for fully automated GI tract bleeding detection and classification. Major functional modules of the SW include: the innovative graph based NCut segmentation algorithm, the unique feature selection and validation method (e.g. illumination invariant features, color independent features, and symmetrical texture features), and the cascade SVM classification for handling various GI tract scenes (e.g. normal tissue, food particles, bubbles, fluid, and specular reflection). Initial evaluation results on the SW have shown zero bleeding instance miss-finding rate and 4.03% false alarm rate. This work is part of our innovative 2D/3D based GI tract disease detection software platform. While the overall SW framework is designed for intelligent finding and classification of major GI tract diseases such as bleeding, ulcer, and polyp from the CE videos, this paper will focus on the automatic bleeding detection functional module.

  2. GISentinel: a software platform for automatic ulcer detection on capsule endoscopy videos

    NASA Astrophysics Data System (ADS)

    Yi, Steven; Jiao, Heng; Meng, Fan; Leighton, Jonathon A.; Shabana, Pasha; Rentz, Lauri

    2014-03-01

    In this paper, we present a novel and clinically valuable software platform for automatic ulcer detection on gastrointestinal (GI) tract from Capsule Endoscopy (CE) videos. Typical CE videos take about 8 hours. They have to be reviewed manually by physicians to detect and locate diseases such as ulcers and bleedings. The process is time consuming. Moreover, because of the long-time manual review, it is easy to lead to miss-finding. Working with our collaborators, we were focusing on developing a software platform called GISentinel, which can fully automated GI tract ulcer detection and classification. This software includes 3 parts: the frequency based Log-Gabor filter regions of interest (ROI) extraction, the unique feature selection and validation method (e.g. illumination invariant feature, color independent features, and symmetrical texture features), and the cascade SVM classification for handling "ulcer vs. non-ulcer" cases. After the experiments, this SW gave descent results. In frame-wise, the ulcer detection rate is 69.65% (319/458). In instance-wise, the ulcer detection rate is 82.35%(28/34).The false alarm rate is 16.43% (34/207). This work is a part of our innovative 2D/3D based GI tract disease detection software platform. The final goal of this SW is to find and classification of major GI tract diseases intelligently, such as bleeding, ulcer, and polyp from the CE videos. This paper will mainly describe the automatic ulcer detection functional module.

  3. Automatic small bowel tumor diagnosis by using multi-scale wavelet-based analysis in wireless capsule endoscopy images.

    PubMed

    Barbosa, Daniel C; Roupar, Dalila B; Ramos, Jaime C; Tavares, Adriano C; Lima, Carlos S

    2012-01-11

    Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.

  4. Coffee Enema for Preparation for Small Bowel Video Capsule Endoscopy: A Pilot Study

    PubMed Central

    Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang

    2014-01-01

    Coffee enemas are believed to cause dilatation of bile ducts and excretion of bile through the colon wall. Proponents of coffee enemas claim that the cafestol palmitate in coffee enhances the activity of glutathione S-transferase, an enzyme that stimulates bile excretion. During video capsule endoscopy (VCE), excreted bile is one of the causes of poor preparation of the small bowel. This study aimed to evaluate the feasibility and effect of coffee enema for preparation of the small bowel during VCE. In this pilot study, 17 of 34 patients were assigned to the coffee enema plus polyethylene glycol (PEG) 2 L ingestion group, whereas the 17 remaining control patients received 2 L of PEG only. The quality of bowel preparation was evaluated in the two patient groups. Bowel preparations in the proximal segments of small bowel were not differ between two groups. In the mid and distal segments of the small intestine, bowel preparations tend to be better in patients who received coffee enemas plus PEG than in patients who received PEG only. The coffee enema group did not experience any complications or side effects. Coffee enemas may be a feasible option, and there were no clinically significant adverse events related to coffee enemas. More prospective randomized studies are warranted to improve small bowel preparation for VCE. PMID:25136541

  5. CHOBS: Color Histogram of Block Statistics for Automatic Bleeding Detection in Wireless Capsule Endoscopy Video.

    PubMed

    Ghosh, Tonmoy; Fattah, Shaikh Anowarul; Wahid, Khan A

    2018-01-01

    Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data.

  6. CHOBS: Color Histogram of Block Statistics for Automatic Bleeding Detection in Wireless Capsule Endoscopy Video

    PubMed Central

    Ghosh, Tonmoy; Wahid, Khan A.

    2018-01-01

    Wireless capsule endoscopy (WCE) is the most advanced technology to visualize whole gastrointestinal (GI) tract in a non-invasive way. But the major disadvantage here, it takes long reviewing time, which is very laborious as continuous manual intervention is necessary. In order to reduce the burden of the clinician, in this paper, an automatic bleeding detection method for WCE video is proposed based on the color histogram of block statistics, namely CHOBS. A single pixel in WCE image may be distorted due to the capsule motion in the GI tract. Instead of considering individual pixel values, a block surrounding to that individual pixel is chosen for extracting local statistical features. By combining local block features of three different color planes of RGB color space, an index value is defined. A color histogram, which is extracted from those index values, provides distinguishable color texture feature. A feature reduction technique utilizing color histogram pattern and principal component analysis is proposed, which can drastically reduce the feature dimension. For bleeding zone detection, blocks are classified using extracted local features that do not incorporate any computational burden for feature extraction. From extensive experimentation on several WCE videos and 2300 images, which are collected from a publicly available database, a very satisfactory bleeding frame and zone detection performance is achieved in comparison to that obtained by some of the existing methods. In the case of bleeding frame detection, the accuracy, sensitivity, and specificity obtained from proposed method are 97.85%, 99.47%, and 99.15%, respectively, and in the case of bleeding zone detection, 95.75% of precision is achieved. The proposed method offers not only low feature dimension but also highly satisfactory bleeding detection performance, which even can effectively detect bleeding frame and zone in a continuous WCE video data. PMID:29468094

  7. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment

    PubMed Central

    Do, Thanh Nho; Seah, Tian En Timothy; Yu, Ho Khek; Phee, Soo Jay

    2016-01-01

    Intra-gastric balloons (IGB) have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient’s stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient’s stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm) is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight. PMID:26815309

  8. Developing assessment system for wireless capsule endoscopy videos based on event detection

    NASA Astrophysics Data System (ADS)

    Chen, Ying-ju; Yasen, Wisam; Lee, Jeongkyu; Lee, Dongha; Kim, Yongho

    2009-02-01

    Along with the advancing of technology in wireless and miniature camera, Wireless Capsule Endoscopy (WCE), the combination of both, enables a physician to diagnose patient's digestive system without actually perform a surgical procedure. Although WCE is a technical breakthrough that allows physicians to visualize the entire small bowel noninvasively, the video viewing time takes 1 - 2 hours. This is very time consuming for the gastroenterologist. Not only it sets a limit on the wide application of this technology but also it incurs considerable amount of cost. Therefore, it is important to automate such process so that the medical clinicians only focus on interested events. As an extension from our previous work that characterizes the motility of digestive tract in WCE videos, we propose a new assessment system for energy based events detection (EG-EBD) to classify the events in WCE videos. For the system, we first extract general features of a WCE video that can characterize the intestinal contractions in digestive organs. Then, the event boundaries are identified by using High Frequency Content (HFC) function. The segments are classified into WCE event by special features. In this system, we focus on entering duodenum, entering cecum, and active bleeding. This assessment system can be easily extended to discover more WCE events, such as detailed organ segmentation and more diseases, by using new special features. In addition, the system provides a score for every WCE image for each event. Using the event scores, the system helps a specialist to speedup the diagnosis process.

  9. QuickView video preview software of colon capsule endoscopy: reliability in presenting colorectal polyps as compared to normal mode reading.

    PubMed

    Farnbacher, Michael J; Krause, Horst H; Hagel, Alexander F; Raithel, Martin; Neurath, Markus F; Schneider, Thomas

    2014-03-01

    OBJECTIVE. Colon capsule endoscopy (CCE) proved to be highly sensitive in detection of colorectal polyps (CP). Major limitation is the time-consuming video reading. The aim of this prospective, double-center study was to assess the theoretical time-saving potential and its possible impact on the reliability of "QuickView" (QV), in the presentation of CP as compared to normal mode (NM). METHODS. During NM reading of 65 CCE videos (mean patient´s age 56 years), all frames showing CPs were collected and compared to the number of frames presented by QV at increasing QV settings (10, 20, ... 80%). Reliability of QV in presenting polyps <6 mm and ≥6 mm (significant polyp), and identifying patients for subsequent therapeutic colonoscopy, capsule egestion rate, cleansing level, and estimated time-saving potential were assessed. RESULTS. At a 30% QV setting, the QV video presented 89% of the significant polyps and 86% of any polyps with ≥1 frame (per-polyp analysis) identified in NM before. At a 10% QV setting, 98% of the 52 patients with significant polyps could be identified (per-patient analysis) by QV video analysis. Capsule excretion rate was 74% and colon cleanliness was adequate in 85%. QV´s presentation rate correlates to the QV setting, the polyp size, and the number of frames per finding. CONCLUSIONS. Depending on its setting, the reliability of QV in presenting CP as compared to NM reading is notable. However, if no significant polyp is presented by QV, NM reading must be performed afterwards. The reduction of frames to be analyzed in QV might speed up identification of candidates for therapeutic colonoscopy.

  10. Electrowetting-based liquid lenses for endoscopy

    NASA Astrophysics Data System (ADS)

    Kuiper, S.

    2011-03-01

    In endoscopy there is a need for cameras with adjustable focus. In flexible and capsule endoscopes conventional focus systems are not suitable, because of restrictions in diameter and lens displacement range. In this paper it is shown that electrowetting-based variable-focus liquid lenses can provide a solution. A theoretical comparison is made between displacing and deforming lenses, and a demonstrator was built to prove the optical feasibility of focusing with liquid lenses in endoscopes.

  11. Short article: Aspiration of capsule endoscopes: a comprehensive review of the existing literature.

    PubMed

    Yung, Diana E; Plevris, John N; Koulaouzidis, Anastasios

    2017-04-01

    Capsule endoscopy (CE) has an excellent safety profile. Although retention is the most cited complication, capsule aspiration is less frequent and is often reported only as isolated cases. This study represents a systematic effort to compile and scrutinize the available data on capsule aspiration to provide comprehensive and conclusive information on this CE complication. A systematic literature search was performed in PubMed, Embase and Chinese National Knowledge Infrastructure. The search terms used were 'capsule endoscopy' AND 'aspiration' (both terms searched as keyword and MeSH). We included case reports and/or series on capsule aspiration, as well as observational cohort studies that reported capsule aspiration among their complications/outcomes. Thirty-four case reports with 37 cases of capsule aspiration were identified. A further four observational studies reported aspiration as part of a cohort of patients undergoing CE. 94.6% of aspirations occurred in elderly men. 87.1% had significant comorbidities. 59.5% had symptoms on aspiration, with cough reported most frequently. The most common location of aspiration was the right main bronchus. Half of the patients required intervention for capsule retrieval; bronchoscopy was the most common management, with good effect. There was a single fatality following capsule aspiration, not directly related to the procedure, and one case of aspiration pneumonia. Outcomes were good for all other patients. The estimated overall aspiration rate is 0.1%. Although very rare and generally safely managed, capsule aspiration should be anticipated in certain patient groups and capsule administration should be approached with necessary precautions.

  12. Wireless endoscopy in 2020: Will it still be a capsule?

    PubMed Central

    Koulaouzidis, Anastasios; Iakovidis, Dimitris K; Karargyris, Alexandros; Rondonotti, Emanuele

    2015-01-01

    Currently, the major problem of all existing commercial capsule devices is the lack of control of movement. In the future, with an interface application, the clinician will be able to stop and direct the device into points of interest for detailed inspection/diagnosis, and therapy delivery. This editorial presents current commercially-available new designs, European projects and delivery capsule and gives an overview of the progress required and progress that will be achieved -according to the opinion of the authors- in the next 5 year leading to 2020. PMID:25954085

  13. Magnetic resonance enterography versus capsule endoscopy activity indices for quantification of small bowel inflammation in Crohn’s disease

    PubMed Central

    Kopylov, Uri; Klang, Eyal; Yablecovitch, Doron; Lahat, Adi; Avidan, Benjamin; Neuman, Sandra; Levhar, Nina; Greener, Tomer; Rozendorn, Noa; Beytelman, Arkadi; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Amitai, Marianne M.; Eliakim, Rami

    2016-01-01

    Background: Video capsule endoscopy (VCE) and magnetic resonance enterography (MRE) are the prime modalities for the evaluation of small bowel (SB) Crohn’s disease (CD). Mucosal inflammation on VCE is quantified using the Lewis score (LS). Diffusion-weighted (DW) magnetic resonance imaging (MRI) allows for accurate assessment of SB inflammation without administration of intravenous contrast material. The Magnetic Resonance Index of Activity (MaRiA) and the Clermont index are quantitative activity indices validated for contrast-enhanced MRE and DW-MRE, respectively. The aim of this study was to compare the quantification of distal SB inflammation by VCE and MR-related activity indices. Methods: Patients with known quiescent SB CD were prospectively recruited and underwent MRE and VCE. LS, MaRIA and Clermont scores were calculated for the distal SB. Results: Both MRI-based indices significantly correlated with the LS and the Clermont index (r = 0.50, p = 0.001 and r = 0.53, p = 0.001, respectively). Both MaRIA and Clermont scores were significantly lower in patients with mucosal healing (LS < 135). The area under the curve (AUC) with both MR scores was moderate for prediction of any mucosal inflammation (LS ⩾ 135) and excellent for prediction of moderate-to-severe inflammation (LS ⩾ 790) (0.71 and 0.74 versus 0.93 and 0.91 for MaRIA and Clermont score, respectively). Conclusions: Modest correlation between VCE- and MRE-based quantitative indices of inflammation in patients with quiescent SB CD was observed. Between-modality correlation was higher in patients with endoscopically severe disease. DW-MRE gauged by Clermont score was at least as accurate as contrast-enhanced MRE for quantification of SB inflammation. PMID:27582877

  14. Endoscopy in inflammatory bowel disease when and why

    PubMed Central

    Rameshshanker, Rajaratnam; Arebi, Naila

    2012-01-01

    Endoscopy plays an important role in the diagnosis and management of inflammatory bowel disease (IBD). It is useful to exclude other aetiologies, differentiate between ulcerative colitis (UC) and Crohn’s disease (CD), and define the extent and activity of inflammation. Ileocolonoscopy is used for monitoring of the disease, which in turn helps to optimize the management. It plays a key role in the surveillance of UC for dysplasia or neoplasia and assessment of post operative CD. Capsule endoscopy and double balloon enteroscopy are increasingly used in patients with CD. Therapeutic applications relate to stricture dilatation and dysplasia resection. The endoscopist’s role is vital in the overall management of IBD. PMID:22720120

  15. Investigation of in-body path loss in different human subjects for localization of capsule endoscope.

    PubMed

    Ara, Perzila; Cheng, Shaokoon; Heimlich, Michael; Dutkiewicz, Eryk

    2015-01-01

    Recent developments in capsule endoscopy have highlighted the need for accurate techniques to estimate the location of a capsule endoscope. A highly accurate location estimation of a capsule endoscope in the gastrointestinal (GI) tract in the range of several millimeters is a challenging task. This is mainly because the radio-frequency signals encounter high loss and a highly dynamic channel propagation environment. Therefore, an accurate path-loss model is required for the development of accurate localization algorithms. This paper presents an in-body path-loss model for the human abdomen region at 2.4 GHz frequency. To develop the path-loss model, electromagnetic simulations using the Finite-Difference Time-Domain (FDTD) method were carried out on two different anatomical human models. A mathematical expression for the path-loss model was proposed based on analysis of the measured loss at different capsule locations inside the small intestine. The proposed path-loss model is a good approximation to model in-body RF propagation, since the real measurements are quite infeasible for the capsule endoscopy subject.

  16. Capsule-odometer: a concept to improve accurate lesion localisation.

    PubMed

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  17. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  18. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    PubMed

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  19. Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging.

    PubMed

    Wei, Wei; Ge, Zhi-Zheng; Lu, Hong; Gao, Yun-Jie; Hu, Yun-Biao; Xiao, Shu-Dong

    2008-01-01

    To evaluate the effects of the various methods of small bowel preparation on the quality of visualization of the small bowel and the gastrointestinal transit time of capsule endoscopy (CE). Ninety patients referred for CE were prospectively randomized to three equal groups according to the preparation used: (a) a control group, in which patients were requested to drink 1 L of clear liquids only, 12 h before the examination; (b) a purgative group, in which patients were requested to ingest 1 L of a polyethylene glycol (PEG)/electrolyte solution only, 12 h before the examination; or (c) a purgative combined with simethicone group (P-S group), in which patients were requested to ingest 1 L of PEG, 12 h before the examination, and 300 mg of simethicone, 20 min before the examination. Effects of the different bowel preparations on the gastric transit time (GTT), small bowel transit time (SBTT), examination completion rate, quality of images of the entire small intestine, and cleansing of the proximal small bowel and distal ileum were evaluated. The number of patients with "adequate" cleansing of the entire small intestine was 17 in the P-S group, 12 in the purgative group, and seven in the control group (P= 0.002). The P-S group had significantly better image quality than the control group (P= 0.001). The P-S group had significantly better image quality for the proximal small bowel (segment A [Seg A]) than the control group (P= 0.0001). Both the P-S group (P= 0.0001) and the purgative group (P= 0.0002) had significantly better image quality for the distal ileum (segment B [Seg B]) than the control group; the P-S group had significantly better image quality than the purgative group as well (P= 0.0121). Gastrointestinal transit time was not different among the three groups, nor was the examination completion rate. Purgative bowel cleansing combined with simethicone before CE improved the quality of imaging of the entire small bowel as well as the visualization of the

  20. Symptomatic retention of the Agile® patency capsule.

    PubMed

    Egea Valenzuela, Juan; Estrella Díez, Esther; Alberca de Las Parras, Fernando

    2017-06-01

    The Agile® capsule has shown to be useful when evaluating the patency of the small bowel in patients prior to capsule endoscopy studies. It is a safe tool and a low rate of complications have been reported, highlighting symptomatic retention, although references in literature are scarce and it is only observed in 1.2% of the procedures. We present the case of a symptomatic retention of this device in a patient with previously known colonic Crohn's disease in who a small bowel study was indicated and was sent for prior patency test.

  1. Subject-friendly entire gastrointestinal screening with a single capsule endoscope by magnetic navigation and the Internet.

    PubMed

    Ohta, Hidetoshi; Katsuki, Shinichi

    2014-01-01

    Ever since capsule endoscopy (CE) was introduced into clinical practice, we gastroenterologists have been dreaming of using this less invasive modality to explore the entire gastrointestinal (GI) tract. To realize this dream, we have developed a magnetic navigation system which includes real-time internet streaming of endoscopic video and some useful gadgets (position detection by means of magnetic impedance (MI) sensors and a modified capsule that is "weightless" in water). The design of the weightless capsule made it possible with 0.5T (Tesla) extracorporeal magnets to control the capsule beyond 20cm. A pair of MI sensors on the body surface could detect subtle magnetic flux generated by an intra-capsular magnet in the GI tract by utilizing the space diversity effect which eliminated the interference of terrestrial magnetism. Subjects underwent CE, during which they were free from confinement in the hospital, except for 1 hour when the capsule was manipulated in the stomach and colon. This study had a completion rate of 97.5%. The high completion rate indicates that our system (single capsule endoscopy-SCE) with further improvements could become a viable modality for screening of the entire GI tract.

  2. Jacobian-Based Iterative Method for Magnetic Localization in Robotic Capsule Endoscopy

    PubMed Central

    Di Natali, Christian; Beccani, Marco; Simaan, Nabil; Valdastri, Pietro

    2016-01-01

    The purpose of this study is to validate a Jacobian-based iterative method for real-time localization of magnetically controlled endoscopic capsules. The proposed approach applies finite-element solutions to the magnetic field problem and least-squares interpolations to obtain closed-form and fast estimates of the magnetic field. By defining a closed-form expression for the Jacobian of the magnetic field relative to changes in the capsule pose, we are able to obtain an iterative localization at a faster computational time when compared with prior works, without suffering from the inaccuracies stemming from dipole assumptions. This new algorithm can be used in conjunction with an absolute localization technique that provides initialization values at a slower refresh rate. The proposed approach was assessed via simulation and experimental trials, adopting a wireless capsule equipped with a permanent magnet, six magnetic field sensors, and an inertial measurement unit. The overall refresh rate, including sensor data acquisition and wireless communication was 7 ms, thus enabling closed-loop control strategies for magnetic manipulation running faster than 100 Hz. The average localization error, expressed in cylindrical coordinates was below 7 mm in both the radial and axial components and 5° in the azimuthal component. The average error for the capsule orientation angles, obtained by fusing gyroscope and inclinometer measurements, was below 5°. PMID:27087799

  3. Remote clinical assessment of gastrointestinal endoscopy (tele-endoscopy): an initial experience.

    PubMed Central

    Kim, C. Y.; Etemad, B.; Glenn, T. F.; Mackey, H. A.; Viator, G. E.; Wallace, M. B.; Mokhashi, M. S.; Cotton, P. B.; Hawes, R. H.

    2000-01-01

    BACKGROUND: Gastrointestinal (GI) endoscopy is an effective tool to screen for cancers of the digestive tract. However, access to endoscopy is limited in many parts of South Carolina. This trial is a part of a prospective multi-part study for remote cancer screening in coastal South Carolina. This pilot study was to evaluate the quality of tele-endoscopy for cancer screening. METHODS: 10 patients scheduled for endoscopic procedures were observed simultaneously by the endoscopist and a remote observer connected over a 512 kbps ISDN line. Findings by both were compared for concordance on malignant or premalignant lesions. RESULTS: The image quality was adequate to support remote diagnosis of GI cancer and abnormal lesions by an experienced observer. However, assessment of the esophagogastric junction for Barrett's esophagus was equivocal. CONCLUSIONS: Overall, our tele-endoscopy setup shows great promise for remote supervision or observation of endoscopic procedures done by nurse endoscopists. Tele-endoscopy is both adequate and feasible for diagnosis of most gastrointestinal lesions. Subtle lesions still may be missed in our current setup. However, improvements are being made in our setup to address the problem with resolution prior to further evaluation. PMID:11079918

  4. Simethicone adjunct to polyethylene glycol improves small bowel capsule endoscopy imaging in non-Crohn's disease patients.

    PubMed

    Papamichael, Konstantinos; Karatzas, Pantelis; Theodoropoulos, Ioannis; Kyriakos, Nikos; Archavlis, Emmanuel; Mantzaris, Gerasimos J

    2015-01-01

    Currently, there is no standardized protocol for bowel preparation before small bowel capsule endoscopy (SBCE). This study aimed to investigate the effect of simethicone combined with polyethylene glycol (PEG) on the visualization quality (VQ) of the SBCE in patients with or without known or suspected Crohn's disease (CD). This observational, prospective, single-center study included consecutive patients undergoing a SBCE between 2007 and 2008. Patients received either a standard bowel cleansing preparation of 2 L PEG and 80 mg simethicone orally 12 and 1 h before SBCE respectively (Group A) or only PEG (Group B). VQ, based on scores for luminal bubbles in frames taken from the small intestine, examination completeness, SBCE diagnostic yield, gastric and small bowel transit times were recorded. Of the 115 patients finally included (Group A, n=56 and Group B, n=59) the cecum was visualized in 103 (89.6%). Simethicone overall improved the VQ in the proximal [OR: 2.43 (95%CI: 1.08-5.45), P=0.032] but not in the distal bowel segment (P=0.064). Nevertheless, this effect was not observed in patients undergoing SBCE for either known or suspected CD. Simethicone as an adjunct to PEG for bowel preparation in patients undergoing SBCE significantly improved the VQ in non-CD patients.

  5. Head or tail: the orientation of the small bowel capsule endoscope movement in the small bowel.

    PubMed

    Kopylov, Uri; Papageorgiou, Neofytos P; Nadler, Moshe; Eliakim, Rami; Ben-Horin, Shomron

    2012-03-01

    The diagnostic accuracy of capsule endoscopy has been suggested to be influenced by the direction of the passage in the intestine. It is currently unknown if a head-first or a tail-first orientation are equally common during the descent through the small bowel. The aim of the study was to identify the orientation of the capsule along the migration through the small bowel. Thirty capsule endoscopies were reviewed by an experienced observer. The direction of the passage through the pylorus and the ileoceccal valve was recorded for all the examinations. In addition, detailed review of the passage of the capsule in different segments of the small bowel was undertaken for all the capsules. The capsule was significantly more likely to pass the pylorus head-first compared to tail-first (25 and 5 out of 30, respectively, OR 5, 95% CI 65-94%, P < 0.001). In 28/30 studies, the capsule exited the ileoceccal valve head-first (OR-14, 95% CI 77-99%, P < 0.001). In an immersion experiment, uneven distribution of weight of the capsule body was demonstrated with the head part (camera tip) being lighter than the tail part. The capsule endoscope usually passes through the pylorus and subsequent segments of the small bowel head-first. This observation suggests that the intestinal peristaltic physiology drives symmetrical bodies with their light part first. The principle of intestinal orientation by weight distribution may bear implications for capsules' design in the future.

  6. Randomized controlled trial of 3 days fasting and oral senna, combined with mannitol and simethicone, before capsule endoscopy

    PubMed Central

    Chen, Hong-bin; Lian-xiang, Peng; Yue, Huang; Chun, Huang; Shu-ping, Xiao; Rong-pang, Lin; Xiao-zong, Wang; Xiao-lin, Li

    2017-01-01

    Abstract Background and Study Aims: The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. Patients and Methods: One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Results: Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ2 = 22.470, P = .000; χ2 = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ2 = 12.390, P = .000, χ2 = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ2 = 0.678, P = .509). Conclusions: Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine. PMID:29069003

  7. Feasibility of a colon capsule overnight procedure followed by colonoscopy.

    PubMed

    Brechmann, T; Schmiegel, W; Klute, L; Rösch, T; Pox, C

    2016-02-01

    Due to limited acceptance of colonoscopy as diagnostic and screening test alternatives are warranted. Colon capsule endoscopy (CCE) has been shown to be a possible filter test, but because of logistical issues a second bowel preparation is usually required, if consecutive colonoscopy is needed. We therefore evaluated the feasibility of a single bowel preparation for both overnight CCE and (therapeutical) colonoscopy thereafter. Patients from two university hospitals referred to undergo colonoscopy were prospectively included in a dual centre feasibility study. A polyethylene glycol (PEG) based bowel preparation-schedule with ingestion of a colon capsule endoscopy (CCE) at 10pm and subsequent colonoscopy at about 12am on the next day was investigated. The first generation PillCam colon capsule was used with 4 different preparation protocols containing several prokinetics in different compositions (i. e. metoclopramide, erythromycin, sennosoides). The main endpoint was the proportion of patients who completed both CCE and colonoscopy; secondary endpoints were capsule transit times, amount of colon seen on CCE, bowel cleanliness, sensitivity and specifity of CCE and patients' acceptance. 50 patients between 18 and 75 years were included. The sequence of overnight colon capsule endoscopy and colonoscopy was successfully completed in all but one (one refused colonoscopy). The capsule was excreted during recording time in 86 % of examinations, visualization of the complete colon was possible in 60 %, but adequate colon preparation was achieved in only 45 % irrespective of the regimen used. The preparation regimen consisting of a PEG-solution, erythromycin as prokinetic drug followed by PEG-solution as boost showed the largest proportion of adequate preparations. Overall sensitivity and specificity of CCE for polyps of any size were 65 % and 76 %, respectively. 26 of 30 patients (86.7 %) returned the subjective assessment questionnaire. 23 patients (88

  8. Macroscopic small bowel mucosal injury caused by chronic nonsteroidal anti-inflammatory drugs (NSAID) use as assessed by capsule endoscopy.

    PubMed

    Caunedo-Alvarez, A; Gómez-Rodríguez, B J; Romero-Vázquez, J; Argüelles-Arias, F; Romero-Castro, R; García-Montes, J M; Pellicer-Bautista, F J; Herrerías-Gutiérrez, J M

    2010-02-01

    To evaluate the type, frequency, and severity of macroscopic small bowel mucosal injury after chronic NSAID intake as assessed by capsule endoscopy (CE), as well as to correlate the severity of gastroduodenal and intestinal damage in these patients. A prospective, endoscopist-blind, controlled trial. Sixteen patients (14F/2M; age: 57.06 +/- 10.16 yrs) with osteoarthritis (OA) on chronic therapy with NSAIDs underwent CE and upper gastrointestinal endoscopy (UGE). Seventeen patients with OA (9F/2M; age: 57.47 +/- 9.82 yrs) who did not take NSAIDs were included as a control group. A scale ranging from 0 to 2 (0 = no lesions, 1-minor = red spots or petechiae, denuded areas and/or 1-5 mucosal breaks; 2-major = > 5 mucosal breaks and/or strictures, or hemorrhage) was designed to assess the severity of small bowel mucosal injuries. CE found intestinal lesions in 75% (12/16) of patients in the study group and in 11.76% (2/17) of controls (p < 0.01). Seven out of 16 NSAID consumers (43.75%) and none in the control group (0%) had a major small bowel mucosal injury (p < 0.01). The percentages of patients with grade 1 and 2 gastroduodenopathy in the study group, as assessed by UGE, were 37.14 and 23.81%, respectively. There was no significant difference in the rate of major enteropathy between patients with none or minor gastroduodenal injury, and those with major gastroduodenopathy (43.75 vs. 40%; p = N.S.). Chronic NSAID intake is associated with a high rate of small bowel mucosal injuries. Our data have failed to demonstrate a relationship between the severity of gastroduodenal and intestinal injury.

  9. Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard videoendoscope.

    PubMed

    Rey, Jean-Francois; Ogata, Haruhiko; Hosoe, Naoki; Ohtsuka, Kazuo; Ogata, Noriyuki; Ikeda, Keiichi; Aihara, Hiroyuki; Pangtay, Ileana; Hibi, Toshifumi; Kudo, Shin-ei; Tajiri, Hisao

    2012-02-01

    Passive video capsule endoscopy is the criterion standard for small-bowel exploration but cannot be used for the large gastric cavity. We report the first blinded comparative clinical trial in humans comparing a magnetically guided capsule endoscope (MGCE) and a conventional high-definition gastroscope. To assess the potential of gastric examination with a guided capsule. Blinded, nonrandomized comparative study. Single endoscopy center. The trial involved 61 patients included in a blinded capsule and gastroscopy comparative study. MGCE examination was performed 24 hours after patients had undergone gastroscopy. To remove food residue or mucus, patients drank 900 mL of water in 2 portions. Then to provide the air-water interface required by the guidance system, they drank 400 mL of water at 35°C. Visualization of the gastric pylorus, antrum, body, fundus, and cardia was evaluated as complete in 88.5%, 86.9%, 93.4%, 85.2%, and 88.5% of patients, respectively. Of gastric lesions, 58.3% were detected by both gastroscopy and MGCE at immediate assessment and review of recorded data. Capsule examination missed 14 findings and gastroscopy missed 31 findings seen with MGCE. Overall diagnostic yield was similar for both modalities. Pilot study. Diagnostic results were similar for the 2 methods. After some technical difficulties related to gastric expansion or presence of mucus had been overcome, this study opened a new field for noninvasive gastric examination in countries where high gastric cancer incidence demands a screening tool. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  10. An ultra-low-power image compressor for capsule endoscope.

    PubMed

    Lin, Meng-Chun; Dung, Lan-Rong; Weng, Ping-Kuo

    2006-02-25

    Gastrointestinal (GI) endoscopy has been popularly applied for the diagnosis of diseases of the alimentary canal including Crohn's Disease, Celiac disease and other malabsorption disorders, benign and malignant tumors of the small intestine, vascular disorders and medication related small bowel injury. The wireless capsule endoscope has been successfully utilized to diagnose diseases of the small intestine and alleviate the discomfort and pain of patients. However, the resolution of demosaicked image is still low, and some interesting spots may be unintentionally omitted. Especially, the images will be severely distorted when physicians zoom images in for detailed diagnosis. Increasing resolution may cause significant power consumption in RF transmitter; hence, image compression is necessary for saving the power dissipation of RF transmitter. To overcome this drawback, we have been developing a new capsule endoscope, called GICam. We developed an ultra-low-power image compression processor for capsule endoscope or swallowable imaging capsules. In applications of capsule endoscopy, it is imperative to consider battery life/performance trade-offs. Applying state-of-the-art video compression techniques may significantly reduce the image bit rate by their high compression ratio, but they all require intensive computation and consume much battery power. There are many fast compression algorithms for reducing computation load; however, they may result in distortion of the original image, which is not good for use in the medical care. Thus, this paper will first simplify traditional video compression algorithms and propose a scalable compression architecture. As the result, the developed video compressor only costs 31 K gates at 2 frames per second, consumes 14.92 mW, and reduces the video size by 75% at least.

  11. KID Project: an internet-based digital video atlas of capsule endoscopy for research purposes.

    PubMed

    Koulaouzidis, Anastasios; Iakovidis, Dimitris K; Yung, Diana E; Rondonotti, Emanuele; Kopylov, Uri; Plevris, John N; Toth, Ervin; Eliakim, Abraham; Wurm Johansson, Gabrielle; Marlicz, Wojciech; Mavrogenis, Georgios; Nemeth, Artur; Thorlacius, Henrik; Tontini, Gian Eugenio

    2017-06-01

    Capsule endoscopy (CE) has revolutionized small-bowel (SB) investigation. Computational methods can enhance diagnostic yield (DY); however, incorporating machine learning algorithms (MLAs) into CE reading is difficult as large amounts of image annotations are required for training. Current databases lack graphic annotations of pathologies and cannot be used. A novel database, KID, aims to provide a reference for research and development of medical decision support systems (MDSS) for CE.  Open-source software was used for the KID database. Clinicians contribute anonymized, annotated CE images and videos. Graphic annotations are supported by an open-access annotation tool (Ratsnake). We detail an experiment based on the KID database, examining differences in SB lesion measurement between human readers and a MLA. The Jaccard Index (JI) was used to evaluate similarity between annotations by the MLA and human readers.  The MLA performed best in measuring lymphangiectasias with a JI of 81 ± 6 %. The other lesion types were: angioectasias (JI 64 ± 11 %), aphthae (JI 64 ± 8 %), chylous cysts (JI 70 ± 14 %), polypoid lesions (JI 75 ± 21 %), and ulcers (JI 56 ± 9 %).  MLA can perform as well as human readers in the measurement of SB angioectasias in white light (WL). Automated lesion measurement is therefore feasible. KID is currently the only open-source CE database developed specifically to aid development of MDSS. Our experiment demonstrates this potential.

  12. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    PubMed

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  13. A locomotion mechanism with external magnetic guidance for active capsule endoscope.

    PubMed

    Wang, Xiaona; Meng, Max Q H; Chen, Xijun

    2010-01-01

    Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.

  14. Intermittent bowel obstruction due to a retained wireless capsule endoscope in a patient with a small bowel carcinoid tumour

    PubMed Central

    Strosberg, Jonathan R; Shibata, David; Kvols, Larry K

    2007-01-01

    A 43-year-old man with a history of metastatic carcinoid disease is presented. The patient had symptoms of chronic intermittent abdominal pain two years after undergoing a wireless capsule endoscopy procedure. Radiological examinations revealed a retained capsule endoscope, and the patient underwent exploratory laparotomy with capsule retrieval. To the authors’ knowledge, this is the first case presentation of chronic, partial small bowel obstruction caused by unrecognized retention of a capsule endoscope. PMID:17299616

  15. Present status of endoscopy, therapeutic endoscopy and the endoscopy training system in Indonesia.

    PubMed

    Makmun, Dadang

    2014-04-01

    Recently, Indonesia was ranked as the fourth most populous country in the world. Based on 2012 data, 85000 general practitioners and 25000 specialists are in service around the country. Gastrointestinal (GI) disease remains the most common finding in daily practise, in both outpatient and inpatient settings, and ranks fifth in causing mortality in Indonesia. Management of patients with GI disease involves all health-care levels with the main portion in primary health care. Some are managed by specialists in secondary health care or are referred to tertiary health care. GI endoscopy is one of the main diagnostic and therapeutic modalities in the management of GI disease. Development of GI endoscopy in Indonesia started before World War II and, today, many GI endoscopy procedures are conducted in Indonesia, both diagnostic and therapeutic. Based on August 2013 data, there are 515 GI endoscopists in Indonesia. Most GI endoscopists are competent in carrying out basic endoscopy procedures, whereas only a few carry out advanced endoscopy procedures, including therapeutic endoscopy. Recently, the GI endoscopy training system in Indonesia consists of basic GI endoscopy training of 3-6 months held at 10 GI endoscopy training centers. GI endoscopy training is also eligible as part of a fellowship program of consultant gastroenterologists held at six accredited fellowship centers in Indonesia. Indonesian Society for Digestive Endoscopy in collaboration with GI endoscopy training centers in Indonesia and overseas has been working to increase quality and number of GI endoscopists, covering both basic and advanced GI endoscopy procedures. © 2014 The Author. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.

  16. Video-based measurements for wireless capsule endoscope tracking

    NASA Astrophysics Data System (ADS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  17. Use of a real-time viewer for endoscopic deployment of capsule endoscope in the pediatric population.

    PubMed

    Bass, Lee M; Misiewicz, Lawrence

    2012-11-01

    Wireless capsule endoscopy (WCE) is an increasingly used procedure for visualization of the small intestine. One challenge in pediatric WCE is the placement of the capsule in a population unable to swallow it for a variety of reasons. Here we present a novel use of the real-time (RT) viewer in the endoscopic deployment of the capsule endoscope. We performed a retrospective chart review on all WCE completed at the Children's Memorial Hospital from February 2010 to May 2011. Following a diagnostic upper endoscopy, the RT viewer was attached to the capsule recorder and image was noted before insertion. The endoscope and AdvanCE capsule delivery device were slowly advanced into duodenum while maintaining visualization on the RT viewer. A total of 17 patients who underwent a WCE with endoscopic placement were identified. They ranged in ages from 2 to 19 years. Thirteen patients required endoscopic placement because of the inability to swallow the capsule, whereas 4 were placed during a scheduled procedure to take advantage of sedation and airway protection. All of the 17 patients had successful deployment of the capsule into the duodenal lumen. In each case, the endoscopist was able to confirm capsule location in duodenum during scope withdrawal. There was no evidence of iatrogenic trauma or bleeding in any patient. There were 5 incomplete studies, a completion rate consistent with that described in the literature. The use of the RT viewer for endoscopic deployment of WCE is an effective technique to improve visualization of capsule placement in the pediatric population.

  18. Small bowel endoluminal imaging (capsule and enteroscopy)

    PubMed Central

    Murino, Alberto

    2017-01-01

    Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice. PMID:28839900

  19. Small bowel endoluminal imaging (capsule and enteroscopy).

    PubMed

    Murino, Alberto; Despott, Edward J

    2017-04-01

    Over the last 16 years, the disruptive technologies of small bowel capsule endoscopy and device-assisted enteroscopy have revolutionised endoluminal imaging and minimally invasive therapy of the small bowel. Further technological developments continue to expand their indications and use. This brief review highlights the state-of-the-art in this arena and aims to summarise the current and potential future role of these technologies in clinical practice.

  20. Small bowel preparations for capsule endoscopy with mannitol and simethicone: a prospective, randomized, clinical trial.

    PubMed

    Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na

    2011-04-01

    There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.

  1. Capsule Endoscopy Crohn's Disease Activity Index (CECDAIic or Niv Score) for the Small Bowel and Colon.

    PubMed

    Niv, Yaron; Gal, Eyal; Gabovitz, Violeta; Hershkovitz, Marcela; Lichtenstein, Lev; Avni, Irit

    2018-01-01

    Crohn's disease (CD) is a chronic inflammatory disorder defined as a transmural inflammation of the bowel wall, affecting the small and large intestine. The Capsule Endoscopy Crohn's Disease Activity Index (CECDAI or Niv score) was devised to measure mucosal disease activity. We extended the Niv score to the colon and have a comprehensive view of the whole intestine. We evaluated 3 parameters of intestinal pathology: A, Inflammation; B, Extent of disease; C, Presence of strictures. The scoring formula is as follows: CEDCAIic=(A1×B1+C1)+(A2×B2+C2)+(A3×B3+C3)+(A4×B4+C4) (1=proximal small bowel, 2=distal small bowel, 3=right colon, 4=left colon). The median CECDAIic score was 15.5 (range, 0 to 42), and the mean±SD score was 17.2±11.5. The CECDAIic scores per patient were similar among the 5 observers. Kendall's coefficient of concordance was high and significant for almost all the parameters examined except for strictures in the proximal small bowel and distal colon. Nevertheless, the coefficients for the small bowel and for the whole intestine were high, 0.85 and 0.77, P<0.0001, respectively. We established a new score, the CECDAIic of the small-bowel and colonic CD. We offer this easy, user-friendly score for use in randomized controlled trials and in the clinical follow-up of CD patients.

  2. Initial experimental evaluation of wireless capsule endoscopes in the bladder: implications for capsule cystoscopy.

    PubMed

    Gettman, Matthew T; Swain, Paul

    2009-05-01

    Cystoscopy remains one of the most important diagnostic procedures for the lower urinary tract. Wireless capsule endoscopy was introduced in the 1990s but use to date is limited to gastroenterology. We evaluated the feasibility in the pig model of using wireless capsule endoscopes (WCEs) for cystoscopy. Experimental evaluation of capsule cystoscopy was performed in a 50-kg farm pig. The capsule was deployed into the bladder through a custom access sheath. Images were continuously transmitted at a rate of four frames per second to a laptop computer and processed using proprietary software. Manipulation of the WCE within the bladder was performed using a set protocol. The animal was then euthanized and gross inspection was performed. We measured the ability to deploy and manipulate the capsule within the bladder. Feasibility of capturing and retrieving images in real time was also assessed. The WCE was efficiently deployed and manipulated within the bladder passively and with the use of external magnets. The entire bladder mucosa was visualized. Real-time image transmission and capture were successful. No complications were seen during capsule cystoscopy. Minor urethral bleeding was observed after the experiment, likely related to placement of the access sheath required for deployment of the WCE. Limitations are that the evaluation of WCE was performed in the pig model, in only one female animal, using a nonsurvival approach. Furthermore, the study was not designed to differentiate normal from abnormal mucosal findings and focused solely on inspection of the bladder. This report suggests that cystoscopy with a WCE is feasible. With this device, all aspects of the bladder mucosa could be visualized, and ongoing technologic and procedural developments are warranted for this new approach.

  3. A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule.

    PubMed

    Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G

    2005-09-01

    The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.

  4. Diagnostic yield and predictive factors of findings in small-bowel capsule endoscopy in the setting of iron-deficiency anemia.

    PubMed

    Olano, Carolina; Pazos, Ximena; Avendaño, Karla; Calleri, Alfonso; Ketzoian, Carlos

    2018-06-01

     Despite the widespread use of small-bowel capsule endoscopy (CE), there is still limited data on its utility and effectiveness for the diagnosis and management of patients with iron-deficiency anemia (IDA).  To assess the diagnostic yield of CE and the factors predicting positive findings in patients with IDA.  Patients with unexplained IDA and negative upper and lower endoscopy were included. A positive diagnostic yield was considered when CE diagnosed one or more lesions that could explain the IDA. Sex, age, NSAID consumption, blood transfusion requirement, and ferritin and hemoglobin levels were recorded.  In total, 120 CE were included (mean age 58.5 years; F/M 82:38). Mean hemoglobin levels were 9 g/dL and mean ferritin levels were 15.7 ng/mL. Positive findings were present in 50 % of patients. The most frequent was angiodysplasia (45 %). Despite several baseline variables being significantly associated with positive findings, using a logistic regression model, it was verified that male sex (OR 3.93; 95 %CI 1.57 - 9.86), age (OR 1.03; 95 %CI 1.00 - 1.06), and hemoglobin levels (OR 0.73; 95 %CI 0.57 - 0.94) were the variables having an independent effect on the probability of obtaining positive findings. Age older than 50 years (OR 14.05; 95 %CI 1.69 - 116.23) and male sex (OR 3.63; 95 %CI 1.29 - 10.17) were the variables which increased the risk of diagnosing angiodysplasia.  CE is a useful technique in patients with IDA. To improve its yield, it is necessary to select patients carefully. Male sex, older age, and low hemoglobin levels were associated with a risk of positive finding in this group of patients. The risk of diagnosing angiodysplasia increased with male sex and older age.

  5. Clinical utility of capsule endoscopy with flexible spectral imaging color enhancement for diagnosis of small bowel lesions

    PubMed Central

    Sato, Yasushi; Sagawa, Tamotsu; Hirakawa, Masahiro; Ohnuma, Hiroyuki; Osuga, Takahiro; Okagawa, Yutaka; Tamura, Fumito; Horiguchi, Hiroto; Takada, Kohichi; Hayashi, Tsuyoshi; Sato, Tsutomu; Miyanishi, Koji; Takimoto, Rishu; Kobune, Masayoshi; Kato, Junji

    2014-01-01

    Background and study aims: The clinical utility of computed virtual chromoendoscopy with flexible spectral imaging color enhancement (FICE) in capsule endoscopy (CE) remains controversial. To clarify the clinical utility of FICE-enhanced CE in evaluating small bowel lesions, we quantitatively assessed white light (WL), FICE, and blue mode (BM) images and examined the sensitivity of these 3 imaging modes of small-bowel lesions from patients who underwent CE. Methods: The CIELAB color difference (∆E) and visual analogue scales (VAS) were measured in 261 CE images (3 different lesion categories) using WL and FICE set 1, 2, and 3, and BM images, respectively. Three endoscopists reviewed CE videos with WL, 3 FICE mode settings, and BM, and compared the sensitivity and detectability for small intestinal diseases from 50 patients who underwent CE. Results: In the assessment of visibility in the 152 vascular lesion images, the ∆E and VAS of FICE set 1, 2, and BM images were significantly higher than that of WL images. In 88 erosion/ulceration images, the ∆E and VAS of FICE set 1 and 2 images were significantly higher than that of WL images. In 21 tumor images, there were no significant differences in ∆E among these modalities. When analyzed on a per-patient basis, FICE settings 1 and 2 had the highest sensitivity (100 %) and specificity (97.3 – 100 %) for vascular lesions. As for erosive/ulcerative lesions, FICE setting 2 had the highest sensitivity (100 %) and specificity (97.2 %). For tumors or polyps, WL had the highest sensitivity (90.9 %) and specificity (87.1 %). In per-lesion analysis, FICE settings 1 and 2 showed significantly superior detection ability over WL for vascular lesions. In the detection of erosive/ulcerative lesions, FICE setting 2 was significantly superior to WL. In tumor images, there was no significant improvement with any of the settings relative to WL images. Conclusions: FICE is most useful for improving CE image

  6. Tethered capsule OCT endomicroscopy for upper gastrointestinal tract imaging by using ball lens probe (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dong, Jing; Gora, Michalina J.; Reddy, Rohith; Trasischker, Wolfgang; Poupart, Oriane; Lu, Weina; Carruth, Robert W.; Grant, Catriona N.; Soomro, Amna R.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-03-01

    While endoscopy is the most commonly used modality for diagnosing upper GI tract disease, this procedure usually requires patient sedation that increases cost and mandates its operation in specialized settings. In addition, endoscopy only visualizes tissue superfically at the macroscopic scale, which is problematic for many diseases that manifest below the surface at a microscopic scale. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. The TCE device is a swallowable capsule that contains optomechanical components that circumferentially scan the OCT beam inside the body as the pill traverses the organ via peristalsis. While we have successfully imaged ~100 patients with the TCE device, the optics of our current device have many elements and are complex, comprising a glass ferrule, optical fiber, glass spacer, GRIN lens and prism. As we scale up manufacturing of this device for clinical translation, we must decrease the cost and improve the manufacturability of the capsule's optical configuration. In this abstract, we report on the design and development of simplificed TCE optics that replace the GRIN lens-based configuration with an angle-polished ball lens design. The new optics include a single mode optical fiber, a glass spacer and an angle polished ball lens, that are all fusion spliced together. The ball lens capsule has resolutions that are comparable with those of our previous GRIN lens configuration (30µm (lateral) × 7 µm (axial)). Results in human subjects show that OCT-based TCE using the ball lens not only provides rapid, high quality microstructural images of upper GI tract, but also makes it possible to implement this technology inexpensively and on a larger scale.

  7. Magnetically Actuated Soft Capsule With the Multimodal Drug Release Function

    PubMed Central

    Yim, Sehyuk; Goyal, Kartik; Sitti, Metin

    2014-01-01

    In this paper, we present a magnetically actuated multimodal drug release mechanism using a tetherless soft capsule endoscope for the treatment of gastric disease. Because the designed capsule has a drug chamber between both magnetic heads, if it is compressed by the external magnetic field, the capsule could release a drug in a specific position locally. The capsule is designed to release a drug in two modes according to the situation. In the first mode, a small amount of drug is continuously released by a series of pulse type magnetic field (0.01–0.03 T). The experimental results show that the drug release can be controlled by the frequency of the external magnetic pulse. In the second mode, about 800 mm3 of drug is released by the external magnetic field of 0.07 T, which induces a stronger magnetic attraction than the critical force for capsule’s collapsing. As a result, a polymeric coating is formed around the capsule. The coated area is dependent on the drug viscosity. This paper presents simulations and various experiments to evaluate the magnetically actuated multimodal drug release capability. The proposed soft capsules could be used as minimally invasive tetherless medical devices with therapeutic capability for the next generation capsule endoscopy. PMID:25378896

  8. Ensure preparation and capsule endoscopy: A two-center prospective study

    PubMed Central

    Niv, Eva; Ovadia, Baruch; Ron, Yulia; Santo, Ervin; Mahajna, Elisabeth; Halpern, Zamir; Fireman, Zvi

    2013-01-01

    AIM: To compare small bowel (SB) cleanliness and capsule endoscopy (CE) image quality following Ensure®, polyethylene glycol (PEG) and standard preparations. METHODS: A preparation protocol for CE that is both efficacious and acceptable to patients remains elusive. Considering the physiological function of the SB as a site for the digestion and absorption of food and not as a stool reservoir, preparation consisting of a liquid, fiber-free formula ingested one day before a CE study might have an advantage over other kinds of preparations. We conducted a prospective, blind-to-preparation, two-center study that compared four types of preparations. The participants’ demographic and clinical data were collected. Gastric and SB transit times were calculated. The presence of bile in the duodenum was scored by a single, blinded-to-preparation gastroenterologist expert in CE, as was cleanliness within the proximal, middle and distal part of the SB. A four-point scale was used (grade 1 = no bile or residue, grade 4 ≥ 90% of lumen full of bile or residual material). RESULTS: The 198 consecutive patients who were referred to CE studies due to routine medical reasons were divided into four groups. They all observed a 12-h overnight fast before undergoing CE. Throughout the 24 h preceding the fast, control group 1 (n = 45 patients) ate light unrestricted meals, control group 2 (n = 81) also ate light meals but free of fruits and vegetables, the PEG group (n = 50) ate unrestricted light meals and ingested the PEG preparation, and the Ensure group (n = 22) ingested only the Ensure formula. Preparation with Ensure improved the visualization of duodenal mucosa (a score of 1.76) by decreasing the bile content compared to preparation with PEG (a score of 2.9) (P = 0.053). Overall, as expected, there was less residue and stool in the proximal part of the SB than in the middle and distal parts in all groups. The total score of cleanliness throughout the length of the SB showed some

  9. Computer-aided decision support systems for endoscopy in the gastrointestinal tract: a review.

    PubMed

    Liedlgruber, Michael; Uhl, Andreas

    2011-01-01

    Today, medical endoscopy is a widely used procedure to inspect the inner cavities of the human body. The advent of endoscopic imaging techniques-allowing the acquisition of images or videos-created the possibility for the development of the whole new branch of computer-aided decision support systems. Such systems aim at helping physicians to identify possibly malignant abnormalities more accurately. At the beginning of this paper, we give a brief introduction to the history of endoscopy, followed by introducing the main types of endoscopes which emerged so far (flexible endoscope, wireless capsule endoscope, and confocal laser endomicroscope). We then give a brief introduction to computer-aided decision support systems specifically targeted at endoscopy in the gastrointestinal tract. Then we present general facts and figures concerning computer-aided decision support systems and summarize work specifically targeted at computer-aided decision support in the gastrointestinal tract. This summary is followed by a discussion of some common issues concerning the approaches reviewed and suggestions of possible ways to resolve them.

  10. Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscope.

    PubMed

    Gao, Mingyuan; Hu, Chengzhi; Chen, Zhenzhi; Zhang, Honghai; Liu, Sheng

    2010-12-01

    This paper investigates design, modeling, simulation, and control issues related to self-propelled endoscopic capsule navigated inside the human body through external magnetic fields. A novel magnetic propulsion system is proposed and fabricated, which has great potential of being used in the field of noninvasive gastrointestinal endoscopy. Magnetic-analysis model is established and finite-element simulations as well as orthogonal design are performed for obtaining optimized mechanical and control parameters for generating appropriate external magnetic field. Simulated intestinal tract experiments are conducted, demonstrating controllable movement of the capsule under the developed magnetic propulsion system.

  11. A video-based speed estimation technique for localizing the wireless capsule endoscope inside gastrointestinal tract.

    PubMed

    Bao, Guanqun; Mi, Liang; Geng, Yishuang; Zhou, Mingda; Pahlavan, Kaveh

    2014-01-01

    Wireless Capsule Endoscopy (WCE) is progressively emerging as one of the most popular non-invasive imaging tools for gastrointestinal (GI) tract inspection. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease. For the WCE, the position of the capsule is defined as the linear distance it is away from certain fixed anatomical landmarks. In order to measure the distance the capsule has traveled, a precise knowledge of how fast the capsule moves is urgently needed. In this paper, we present a novel computer vision based speed estimation technique that is able to extract the speed of the endoscopic capsule by analyzing the displacements between consecutive frames. The proposed approach is validated using a virtual testbed as well as the real endoscopic images. Results show that the proposed method is able to precisely estimate the speed of the endoscopic capsule with 93% accuracy on average, which enhances the localization accuracy of the WCE to less than 2.49 cm.

  12. European Society of Gastrointestinal Endoscopy - Establishing the key unanswered research questions within gastrointestinal endoscopy.

    PubMed

    Rees, Colin J; Ngu, Wee Sing; Regula, Jaroslaw; Bisschops, Raf; Saftoiu, Adrian; Dekker, Evelien; Gralnek, Ian; Ciocirlan, Mihai; Dinis-Ribeiro, Mario; Jover, Rodrigo; Meisner, Søren; Spada, Cristiano; Hassan, Cesare; Valori, Roland; Hucl, Tomas; Le Moine, Olivier; Domagk, Dirk; Kaminski, Michal F; Bretthauer, Michael; Rutter, Matthew D; Aabakken, Lars; Ponchon, Thierry; Fockens, Paul; Siersema, Peter D

    2016-10-01

    Background and study aim: Gastrointestinal endoscopy is a rapidly evolving research field. The European Society of Gastrointestinal Endoscopy (ESGE) plays a key role in shaping opinion and endoscopy activity throughout Europe and further afield. Establishing key unanswered questions within the field of endoscopy and prioritizing those that are important enables researchers and funders to appropriately allocate resources. Methods: Over 2 years, the ESGE Research Committee gathered information on research priorities and refined them through a modified Delphi approach. Consultations were held with the ESGE Governing Board and Quality Improvement Committee to identify important unanswered questions. Research workshops were held at the 21st United European Gastroenterology Week. Research questions were refined by the ESGE Research Committee and Governing Board, compiled into an online survey, and distributed to all ESGE members, who were invited to rank each question by priority. Results: The final questionnaire yielded 291 responses from over 60 countries. The three countries with the highest response rates were Spain, Italy, and United Kingdom. Most responders were from teaching hospitals (62 %) and were specialist endoscopists (51 %). Responses were analyzed with weighted rankings, resulting in prioritization of 26 key unanswered questions. The top ranked generic questions were: 1) How do we define the correct surveillance interval following endoscopic diagnosis? 2) How do we correctly utilize advanced endoscopic imaging? 3) What are the best markers of endoscopy quality? Conclusion: Following this comprehensive process, the ESGE has identified and ranked the key unanswered questions within the field of gastrointestinal endoscopy. Researchers, funders, and journals should prioritize studies that seek to answer these important questions. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Small bowel video capsule endoscopy in Crohn's disease: What have we learned in the last ten years?

    PubMed

    Lucendo, Alfredo J; Guagnozzi, Danila

    2011-02-16

    Since its introduction in 2001, capsule endoscopy (CE) has become the most important advance in the study of small bowel disease, including Crohn's disease (CD). This technique has been demonstrated to be superior to all other current forms of radiological investigation in detecting mucosal abnormalities of small bowel nonstricturing CD. CE has proven to be extremely useful in diagnosing CD in patients with inconclusive findings from ileocolonoscopy and x-ray-based studies. Almost half of all patients with CD involving the ileum also present lesions in proximal intestinal segments, with the small bowel being exclusively involved in up to 30% of all CD cases. Despite the widespread use of CE, several questions concerning the utility of this technique remain unanswered. The lack of commonly agreed diagnostic criteria for defining CD lesions with the aid of CE may have had an influence on the variation in diagnostic results for CE reported in the literature. The utility of CE in monitoring CD and in guiding therapy has also been proposed. Furthermore, CE could be a useful second-line technique for patients with an established diagnosis of CD and unexplained symptoms. Finally, as no threshold for CD diagnosis has been agreed upon, a severity scale of mucosal disease activity has not been universally followed. None of the available activity indexes based on CE findings has been independently validated. This article discusses several cutting-edge aspects of the usefulness of CE in CD 10 years after its introduction as a sensible method to study the small intestine.

  14. Spectrum of small-bowel mucosal abnormalities identified by capsule endoscopy in patients with portal hypertension of varied etiology.

    PubMed

    Chandrasekar, T S; Janakan, Gokul Bollu; Chandrasekar, Viveksandeep Thoguluva; Kalamegam, Raja Yogesh; Suriyanarayanan, Sathiamoorthy; Sanjeevaraya, Prasad Menta

    2017-01-01

    Bleeding from small intestinal ectopic varices and persistent anemia caused by portal hypertensive enteropathy (PHE) can be very challenging. Capsule endoscopy (CE) is one of the best noninvasive modalities in identifying such lesions. The aims of this study are to study the prevalence of small-bowel changes related to portal hypertension (PHT) and to correlate them with the observations related to the effects of portal hypertension in the esophagus, stomach, and colon. Thirty-two patients with various etiologies of PHT with either anemia or gastrointestinal bleed were included along with age- and sex-matched controls without PHT. All patients underwent blood tests, gastroscopy, colonoscopy, and CE. The small-bowel findings by CE were categorized as inflammatory-like and vascular lesions. The small-bowel changes were analyzed to find out any association with various demographic, clinical, and endoscopic variables. Thirty-one out of 32 patients with PHT (96.8%) had PHE identified by CE. Of them, 31 (96.8%) had inflammatory-like appearance, 11 (34.4%) had vascular lesions, and 2 (6.2%) had small-bowel varices. Inflammatory-like appearance was noted in eight (25%) and angiodysplastic lesions in two (6.2%) controls. Findings compatible with PHE were detected in 96.8% of the patients and 25% of the controls (X 2 =34.72, p=0.000).The presence of PHE was not associated with any of the above-mentioned variables. Small-bowel mucosal changes were seen in significantly higher number of patients with PHT with anemia.

  15. Visualization of Flow Separation Around an Atmospheric Entry Capsule at Low-Subsonic Mach Number Using Background-Oriented Schlieren (BOS)

    NASA Technical Reports Server (NTRS)

    Mizukaki, Toshiharu; Borg, Stephen E.; Danehy, Paul M.; Murman, Scott M.

    2014-01-01

    This paper presents the results of visualization of separated flow around a generic entry capsule that resembles the Apollo Command Module (CM) and the Orion Multi-Purpose Crew Vehicle (MPCV). The model was tested at flow speeds up to Mach 0.4 at a single angle of attack of 28 degrees. For manned spacecraft using capsule-shaped vehicles, certain flight operations such as emergency abort maneuvers soon after launch and flight just prior to parachute deployment during the final stages of entry, the command module may fly at low Mach number. Under these flow conditions, the separated flow generated from the heat-shield surface on both windward and leeward sides of the capsule dominates the wake flow downstream of the capsule. In this paper, flow visualization of the separated flow was conducted using the background-oriented schlieren (BOS) method, which has the capability of visualizing significantly separated wake flows without the particle seeding required by other techniques. Experimental results herein show that BOS has detection capability of density changes on the order of 10(sup-5).

  16. Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment (with videos).

    PubMed

    Kim, Hee Man; Yang, Sungwook; Kim, Jinseok; Park, Semi; Cho, Jae Hee; Park, Jeong Youp; Kim, Tae Song; Yoon, Eui-Sung; Song, Si Young; Bang, Seungmin

    2010-08-01

    Capsule endoscopy that could actively move and approach a specific site might be more valuable for the diagnosis or treatment of GI diseases. We tested the performance of active locomotion of a novel wired capsule endoscope with a paddling-based locomotion mechanism, using 3 models: a silicone tube, an extracted porcine colon, and a living pig. In vitro, ex vivo, and in vivo experiments in a pig model. Study in an animal laboratory. For the in vitro test, the locomotive capsule was controlled to actively move from one side of a silicone tube to the other by a controller-operated automatic traveling program. The velocity was calculated by following a video recording. We performed ex vivo tests by using an extracted porcine colon in the same manner we performed the in vitro test. In in vivo experiments, the capsule was inserted into the rectum of a living pig under anesthesia, and was controlled to move automatically forward. After 8 consecutive trials, the velocity was calculated. Elapsed time, velocity, and mucosal damage. The locomotive capsule showed stable and active movement inside the lumen both in vitro and ex vivo. The velocity was 60 cm/min in the silicone tube, and 36.8 and 37.5 cm/min in the extracted porcine colon. In the in vivo experiments, the capsule stably moved forward inside the colon of a living pig without any serious complications. The mean velocity was 17 cm/min over 40 cm length. We noted pinpoint erythematous mucosal injuries in the colon. Porcine model experiments, wired capsule endoscope. The novel paddling-based locomotive capsule endoscope performed fast and stable movement in a living pig colon with consistent velocity. Further investigation is necessary for practical use in humans. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Abnormal Image Detection in Endoscopy Videos Using a Filter Bank and Local Binary Patterns

    PubMed Central

    Nawarathna, Ruwan; Oh, JungHwan; Muthukudage, Jayantha; Tavanapong, Wallapak; Wong, Johnny; de Groen, Piet C.; Tang, Shou Jiang

    2014-01-01

    Finding mucosal abnormalities (e.g., erythema, blood, ulcer, erosion, and polyp) is one of the most essential tasks during endoscopy video review. Since these abnormalities typically appear in a small number of frames (around 5% of the total frame number), automated detection of frames with an abnormality can save physician’s time significantly. In this paper, we propose a new multi-texture analysis method that effectively discerns images showing mucosal abnormalities from the ones without any abnormality since most abnormalities in endoscopy images have textures that are clearly distinguishable from normal textures using an advanced image texture analysis method. The method uses a “texton histogram” of an image block as features. The histogram captures the distribution of different “textons” representing various textures in an endoscopy image. The textons are representative response vectors of an application of a combination of Leung and Malik (LM) filter bank (i.e., a set of image filters) and a set of Local Binary Patterns on the image. Our experimental results indicate that the proposed method achieves 92% recall and 91.8% specificity on wireless capsule endoscopy (WCE) images and 91% recall and 90.8% specificity on colonoscopy images. PMID:25132723

  18. In Vivo Characterization of a Wireless Telemetry Module for a Capsule Endoscopy System Utilizing a Conformal Antenna.

    PubMed

    Faerber, Julia; Cummins, Gerard; Pavuluri, Sumanth Kumar; Record, Paul; Rodriguez, Adrian R Ayastuy; Lay, Holly S; McPhillips, Rachael; Cox, Benjamin F; Connor, Ciaran; Gregson, Rachael; Clutton, Richard Eddie; Khan, Sadeque Reza; Cochran, Sandy; Desmulliez, Marc P Y

    2018-02-01

    This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10 -3 packet error rate and 10 -5 bit error rate and no temperature increase of the tissue according to IEEE standards.

  19. A multicenter, prospective, randomized comparison of a novel signal transmission capsule endoscope to an existing capsule endoscope.

    PubMed

    Choi, Eric H; Mergener, Klaus; Semrad, Carol; Fisher, Laurel; Cave, David R; Dodig, Milan; Burke, Carol; Leighton, Jonathan A; Kastenberg, David; Simpson, Peter; Sul, James; Bhattacharya, Kanishka; Charles, Roger; Gerson, Lauren; Weber, Luke; Eisen, Glenn; Reidel, Warren; Vargo, John J; Wakim-Fleming, Jamile; Lo, Simon K

    2013-08-01

    MiroCam, a capsule endoscope, uses a novel transmission technology, electric-field propagation, which uses the human body as a conduction medium for data transmission. To compare the ability of the MiroCam (MC) and PillCam (PC) to identify sources of obscure GI bleeding (OGIB). Prospective, multicenter, comparative study. Six academic hospitals. A total of 105 patients with OGIB. Patients ingested both the MC and PC capsules sequentially in a randomized fashion. Concordance of rates in identifying a source of OGIB, operational times, and rates of complete small-bowel examination. Data analysis resulted in 43 (48%) "abnormal" cases identifying a source of OGIB by either capsule. Twenty-four cases (55.8%) were positive by both capsules. There was negative agreement in 46 of 58 cases (79.3%). The κ index was 0.547 (χ(2) = 1.32; P = .36). In 12 cases, MC positively identified a source that was not seen on PC, whereas in 7 cases, PC positively identified a source that was not seen on MC. MC had a 5.6% higher rate of detecting small-bowel lesions (P = .54). MC captured images at 3 frames per second for 11.1 hours, and PC captured images at 2 frames per second for 7.8 hours (P < .0001). Complete small-bowel examination was achieved in 93.3% for MC and 84.3% for PC (P = .10). Readers were not blinded to the particular capsule they were reading. A positive diagnostic finding for OGIB was identified by either capsule in 48% of cases. The concordance rate between the 2 capsules was comparable to that of prior studies in identifying sources of small-bowel bleeding. The longer operational time of the MC may result in higher rates of complete small-bowel examination, which may, in turn, translate into a higher rate of detecting small-bowel lesions. ( NCT00878982.). Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  20. Dual-Level Security based Cyclic18 Steganographic Method and its Application for Secure Transmission of Keyframes during Wireless Capsule Endoscopy.

    PubMed

    Muhammad, Khan; Sajjad, Muhammad; Baik, Sung Wook

    2016-05-01

    In this paper, the problem of secure transmission of sensitive contents over the public network Internet is addressed by proposing a novel data hiding method in encrypted images with dual-level security. The secret information is divided into three blocks using a specific pattern, followed by an encryption mechanism based on the three-level encryption algorithm (TLEA). The input image is scrambled using a secret key, and the encrypted sub-message blocks are then embedded in the scrambled image by cyclic18 least significant bit (LSB) substitution method, utilizing LSBs and intermediate LSB planes. Furthermore, the cover image and its planes are rotated at different angles using a secret key prior to embedding, deceiving the attacker during data extraction. The usage of message blocks division, TLEA, image scrambling, and the cyclic18 LSB method results in an advanced security system, maintaining the visual transparency of resultant images and increasing the security of embedded data. In addition, employing various secret keys for image scrambling, data encryption, and data hiding using the cyclic18 LSB method makes the data recovery comparatively more challenging for attackers. Experimental results not only validate the effectiveness of the proposed framework in terms of visual quality and security compared to other state-of-the-art methods, but also suggest its feasibility for secure transmission of diagnostically important keyframes to healthcare centers and gastroenterologists during wireless capsule endoscopy.

  1. Small bowel video capsule endoscopy in Crohn’s disease: What have we learned in the last ten years?

    PubMed Central

    Lucendo, Alfredo J; Guagnozzi, Danila

    2011-01-01

    Since its introduction in 2001, capsule endoscopy (CE) has become the most important advance in the study of small bowel disease, including Crohn’s disease (CD). This technique has been demonstrated to be superior to all other current forms of radiological investigation in detecting mucosal abnormalities of small bowel nonstricturing CD. CE has proven to be extremely useful in diagnosing CD in patients with inconclusive findings from ileocolonoscopy and x-ray-based studies. Almost half of all patients with CD involving the ileum also present lesions in proximal intestinal segments, with the small bowel being exclusively involved in up to 30% of all CD cases. Despite the widespread use of CE, several questions concerning the utility of this technique remain unanswered. The lack of commonly agreed diagnostic criteria for defining CD lesions with the aid of CE may have had an influence on the variation in diagnostic results for CE reported in the literature. The utility of CE in monitoring CD and in guiding therapy has also been proposed. Furthermore, CE could be a useful second-line technique for patients with an established diagnosis of CD and unexplained symptoms. Finally, as no threshold for CD diagnosis has been agreed upon, a severity scale of mucosal disease activity has not been universally followed. None of the available activity indexes based on CE findings has been independently validated. This article discusses several cutting-edge aspects of the usefulness of CE in CD 10 years after its introduction as a sensible method to study the small intestine. PMID:21403813

  2. Meta-analysis shows similar re-bleeding rates among Western and Eastern populations after index video capsule endoscopy.

    PubMed

    Tziatzios, Georgios; Gkolfakis, Paraskevas; Hassan, Cesare; Toth, Ervin; Zullo, Angelo; Koulaouzidis, Anastasios; Dimitriadis, George D; Triantafyllou, Konstantinos

    2018-03-01

    Video capsule endoscopy (VCE) is the first-line diagnostic procedure for investigating obscure gastrointestinal bleeding (OGIB). Different re-bleeding rates following index VCE have been reported among Western and Eastern studies. We conducted a comprehensive literature search to identify studies examining re-bleeding rates after VCE for OGIB. Meta-analysis assessed the pooled proportion of re-bleeding events after VCE for OGIB according to study's origin (Western vs. Eastern) and according to the length of follow-up (≥24 months vs. <24 months). We also calculated the re-bleeding odds ratios (OR; 95% CI) after positive vs. negative index VCE, overt vs. occult initial presentation of bleeding and after interventional treatment for positive index cases, according to the study's origin. We included 46 (30 Western and 16 Eastern) studies with 5796 patients. Significant heterogeneity was detected among meta-analyzed studies. Overall, the pooled re-bleeding rate was similar between Western (29%; 95% CI: 23-34) and Eastern (21%; 95% CI: 15-27) populations, irrespective of the length of follow-up. The odds of re-bleeding was significantly higher after positive as compared to negative index VCE in Eastern studies (OR: 1.77; 95% CI: 1.07-2.94). Application of specific treatment after positive index VCE was associated with lower re-bleeding odds in both Western (OR: 0.37; 95% CI: 0.16-0.87) and Eastern (OR: 0.39; 95% CI: 0.21-0.72) populations. Patients undergoing VCE for OGIB have similar re-bleeding rates in the East and the West, regardless of the length of follow-up. However, increased re-bleeding odds after positive index VCE is observed in Eastern studies. Copyright © 2018 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. A case of small bowel ulcer caused by NSAIDs and detected after capsule endoscope retention.

    PubMed

    Sakuma, Toshiyuki; Gocho, Seiho; Ogasawara, Fusao; Tsukune, Yoko; Sawamoto, Kana; Numata, Makoto; Nagata, Naruhiko; Deguchi, Ryuzo; Mine, Tetsuya

    2012-04-20

    We recently detected an annular ulcer thought to have been caused by non-steroidal anti-inflammatory drugs (NSAIDs) when we performed small bowel capsule endoscopy on a patient with suspected small-bowel bleeding and a history of frequent use of oral NSAIDs. The patient was a 64-year-old woman who complained of bloody stools and abdominal pain. The annular ulcer showed concentric stenosis, which caused retention of the capsule endoscope. NSAIDs are some of the most frequently used anti-inflammatory analgesics, and even more frequent use can be expected with the aging of society. No reports to date appear to have described retention of a capsule endoscope due to annular ulceration caused by NSAIDs. We report herein our experience with a patient showing small-bowel ulcer caused by NSAIDs.

  4. The relationship between physical activity level and completion rate of small bowel examination in patients undergoing capsule endoscopy.

    PubMed

    Shibuya, Tomoyoshi; Mori, Hiroki; Takeda, Tsutomu; Konishi, Masae; Fukuo, Yuka; Matsumoto, Kenshi; Beppu, Kazuko; Sakamoto, Naoto; Osada, Taro; Nagahara, Akihito; Otaka, Michiro; Ogihara, Tatsuo; Watanabe, Sumio

    2012-01-01

    Capsule endoscopy (CE) allows direct examination of the small bowel in a safe, noninvasive and well-tolerated manner. Nonetheless, experience indicates failure to reach the cecum in 20-30% of patients within the 8 hour battery life. Attempts to improve the completion rate (CR) as defined by reaching the cecum have been unsuccessful. This study was to investigate the relationship between patients' physical activity and CR. Between January 2009 and January 2010, 76 patients (44 men, 32 women; median age 64.5 yr) underwent CE for the diagnosis of small intestinal disorders. Indications for CE were obscure gastrointestinal bleeding/anemia (62 cases), others (14 cases). Patients were divided into an outpatient group (n=23), mild bed rest group (n=35) and strict bed rest group (n=18). For all patients, the average gastric transit time was 65.5 minutes, small bowel transit time was 301.4 minutes and the CR was 86.8%. However, the CR was 100% (23/23) in the outpatient group, an 85.7% (30/35) in the mild bed rest group, and 72.2% (13/18) in the strict bed rest group. The CR increased with physical activity of patients by Cochran-Armitage Trend Test (p=0.009). In multivariate logistic regression analyses, low physical activity was a significant risk factor for failure to reach the cecum during CE examination; adjusted OR: 3.39, 95% CI: 1.01-11.42 (p=0.048). Our observations suggested that increasing physical activity would increase the likelihood of a complete bowel examination by CE. Further, for CE, inconvenient bowel preparations like the use of polyethylene glycol may be avoided.

  5. Randomized controlled trial of 3 days fasting and oral senna, combined with mannitol and simethicone, before capsule endoscopy.

    PubMed

    Chen, Hong-Bin; Lian-Xiang, Peng; Yue, Huang; Chun, Huang; Shu-Ping, Xiao; Rong-Pang, Lin; Xiao-Zong, Wang; Xiao-Lin, Li

    2017-10-01

    The approach to small bowel preparation before capsule endoscopy (CE) is still suboptimal. One hundred eighty patients were randomly allocated to 3 groups. Patients in Group A took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In Group B the same preparation was taken at 20:00 on the day before, and at 05:00 on the day of CE; in addition, 20 mL oral simethicone was taken 30 minutes before CE. Group C was treated identically to Group B, except that the patients fasted for 3 days and took 3 g senna orally 3 times daily before CE. The length of bowel containing green luminal contents was assessed by ImageJ software and bowel cleanliness was evaluated by computed assessment of the cleansing score. Cleansing of the whole small bowel and the distal small bowel were significantly different between the 3 groups (χ = 22.470, P = .000; χ = 17.029, P = .000, respectively). There were also significant differences between the 3 groups in the length of small bowel and specifically the length of the distal small bowel containing green luminal contents (χ = 12.390, P = .000, χ = 15.141, P = .000, respectively), but not with regard to the proximal small bowel (χ = 0.678, P = .509). Three days fasting and oral senna, combined with 20% mannitol and simethicone, before CE, can reduce the effects of bile on the small bowel and improve small bowel cleansing, especially in the distal small intestine.

  6. Capsule endoscopy with PillCamSB2 versus PillCamSB3: has the improvement in technology resulted in a step forward?

    PubMed

    Xavier, Sofia; Monteiro, Sara; Magalhães, Joana; Rosa, Bruno; Moreira, Maria João; Cotter, José

    2018-03-01

    To compare the findings and completion rate of PillCam® SB2 and SB3. This was a retrospective single-center study that included 357 consecutive small bowel capsule endoscopies (SBCE), 173 SB2 and 184 SB3. The data collected included age, gender, capsule type (PillCam® SB2 or SB3), quality of bowel preparation, completion of the examination, gastric and small bowel transit time, small bowel findings, findings in segments other than the small bowel and the detection of specific anatomical markers, such as the Z line and papilla. The mean age of the patients was 48 years and 66.9% were female. The two main indications were suspicion/staging of inflammatory bowel disease (IBD) and obscure gastrointestinal bleeding (OGIB) (43.7% and 40.3%, respectively). Endoscopic findings were reported in 76.2% of examinations and 53.5% were relevant findings. No significant differences were found between SB2 and SB3 with regard to completion rate (93.6% vs 96.2%, p = 0.27), overall endoscopic findings (73.4% vs 78.8%, p = 0.23), relevant findings (54.3% vs 52.7%, p = 0.76), first tertile findings (43.9% vs 48.9%, p = 0.35), extra-SB findings (23.7% vs 17.3%, p = 0.14), Z line and papilla detection rate (35.9% vs 35.7%, p = 0.97 and 27.1% vs 32.6%, p = 0.32, respectively). With regard to the patient subgroups with suspicion/staging of IBD, significant differences were found in relation to the detection of villous edema and the 3rd tertile findings, thus favoring SB3 (26.3% vs 43.8%, p = 0.02 and 47.4% vs 66.3%, p = 0.02, respectively). Mucosal atrophy was significantly more frequently diagnosed with the PillCam® SB3 in patients with anemia/OGIB (0% vs 8%, p = 0.03). Overall, PillCam® SB3 did not improve the diagnostic yield compared to SB2, although it improved the detection of villous atrophy and segmental edema.

  7. Blood detection in wireless capsule endoscope images based on salient superpixels.

    PubMed

    Iakovidis, Dimitris K; Chatzis, Dimitris; Chrysanthopoulos, Panos; Koulaouzidis, Anastasios

    2015-08-01

    Wireless capsule endoscopy (WCE) enables screening of the gastrointestinal (GI) tract with a miniature, optical endoscope packed within a small swallowable capsule, wirelessly transmitting color images. In this paper we propose a novel method for automatic blood detection in contemporary WCE images. Blood is an alarming indication for the presence of pathologies requiring further treatment. The proposed method is based on a new definition of superpixel saliency. The saliency of superpixels is assessed upon their color, enabling the identification of image regions that are likely to contain blood. The blood patterns are recognized by their color features using a supervised learning machine. Experiments performed on a public dataset using automatically selected first-order statistical features from various color components indicate that the proposed method outperforms state-of-the-art methods.

  8. Jejunal varices diagnosed by capsule endoscopy in patients with post-liver transplant portal hypertension.

    PubMed

    Bass, Lee M; Kim, Stanley; Superina, Riccardo; Mohammad, Saeed

    2017-02-01

    Portal hypertension secondary to portal vein obstruction following liver transplant occurs in 5%-10% of children. Jejunal varices are uncommon in this group. We present a case series of children with significant GI blood loss, negative upper endoscopy, and jejunal varices detected by CE. Case series of patients who had CE for chronic GI blood loss following liver transplantation. Three patients who had their initial transplants at a median age of 7 months were identified at our institution presenting at a median age of 8 years (range 7-16 years) with a median Hgb of 2.8 g/dL (range 1.8-6.8 g/dL). Upper endoscopy was negative for significant esophageal varices, gastric varices, and bleeding portal gastropathy in all three children. All three patients had significant jejunal varices noted on CE in mid-jejunum. Jejunal varices were described as large prominent bluish vessels underneath visualized mucosa, one with evidence of recent bleeding. The results led to venoplasty of the portal vein in two patients and a decompressive shunt in one patient with resolution of GI bleed and anemia. CE is useful to diagnose intestinal varices in children with portal hypertension and GI bleeding following liver transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Swallowable capsule with air channel for improved image-guided cancer detection in the esophagus

    NASA Astrophysics Data System (ADS)

    Seibel, Eric J.; Melville, C. David; Lung, Jonathan K. C.; Babchanik, Alexander P.; Lee, Cameron M.; Johnston, Richard S.; Dominitz, Jason A.

    2009-02-01

    A new type of endoscope has been developed and tested in the human esophagus, a tethered-capsule endoscope (TCE) that requires no sedation for oral ingestion and esophageal inspection. The TCE uses scanned red, green, and blue laser light to image the upper digestive tract using a swallowable capsule of 6.4mm in diameter and 18mm in length on a 1.4mm diameter tether. The TCE has been modified for image-guided interventions in the lower esophagus, specifically for more effective detection and measurement of the extent of Barrett's esophagus, a precursor to esophageal cancer. Three modifications have been tested in vivo: (1) weighting the capsule so it is negatively buoyant in water, (2) increasing the frame rate of 500-line images to 30 Hz (video rate), and (3) adding a 1.0mm inner diameter working channel alongside the tether for distending the lower esophagus with air pressure during endoscopy. All three modifications proved effective for more clearly visualizing the lower esophagus in the first few human subjects. The air channel was especially useful because it did not change tolerability in the first subject for unsedated endoscopy and the air easily removed bubbles obscuring tissue from the field of view. The air provided a non-invasive intervention by stimulating the mechanosensor of the lower esophageal sphincter at the precise time that the TCE was positioned for most informative imaging. All three TCE modifications proved successful for improved visualization of esophageal pathology, such as suspected Barrett's esophagus, without the use of sedation.

  10. Should bowel preparation, antifoaming agents, or prokinetics be used before video capsule endoscopy? A systematic review and meta-analysis.

    PubMed

    Kotwal, Vikram S; Attar, Bashar M; Gupta, Saurabh; Agarwal, Rajender

    2014-02-01

    The ideal bowel preparation regime before small bowel video capsule endoscopy (VCE) is not known. We carried out a systematic review and meta-analysis to study the effect of purgatives, antifoaming agents, and prokinetics on the outcomes associated with VCE. We performed literature searches in MEDLINE and Cochrane Library and included randomized-controlled trials studying the effect of purgatives, antifoaming agents, and prokinetics in patients undergoing VCE. Our outcomes of interest were visualization quality, diagnostic yield, and completion rate. Meta-analyses were carried out using the RevMan software and heterogeneity was assessed using the I statistic. Fifteen studies fulfilled the inclusion criteria. As compared with no bowel preparation, bowel preparation with polyethylene glycol (PEG) led to adequate visualization in a significantly higher number of patients undergoing VCE [odds ratio (OR) 3.13; 95% confidence interval (CI) 1.70-5.75]. Both PEG and sodium phosphate significantly improved the diagnostic yield (OR 1.68; 95% CI 1.16-2.42 and OR 1.77; 95% CI 1.18-2.64, respectively) but did not affect the completion rate. All studies with simethicone showed significantly improved visualization quality with its use as compared with overnight fasting or purgatives alone. Prokinetics did not significantly improve the completion rate of VCE. On the basis of the data available, a combination of PEG and simethicone appears to be the best approach for small bowel preparation before VCE. However, large multicenter randomized-controlled trials are needed to validate this recommendation and to evaluate the ideal dose of PEG and timing of bowel preparation before VCE. Prokinetics administered before VCE do not improve the completion rate and should not be used.

  11. Guidelines for designing a digestive disease endoscopy unit: report of the World Endoscopy Organization.

    PubMed

    Mulder, Chris J J; Jacobs, Maarten A J M; Leicester, Roger J; Nageshwar Reddy, D; Shepherd, Libby E A; Axon, Anthony T; Waye, Jerome D

    2013-07-01

    A dedicated digestive disease endoscopy unit is structurally and functionally differentiating rapidly as a result of increasing diagnostic and therapeutic possibilities in the last 10-20 years. Publications with practical details are scarce, imposing a challenge in the construction of such a unit. The lack of authoritative information about endoscopy unit design means that architects produce their own design with or without consulting endoscopists working in such a unit. A working group of the World Endoscopy Organization discussed and outlined a practical approach fordesign and construction of a modern endoscopy unit. Designing the layout is extremely important, necessitating thoughtful planning to provide comfort to the endoscopy staff and patients, and efficient data archiving and transmission during endoscopic services. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  12. Capsule Endoscopy

    MedlinePlus

    ... attached to your abdomen. Each patch contains an antenna with wires that connect to a recorder. Some ... your waist. The camera sends images to an antenna on your abdomen, which feeds the data to ...

  13. Usefulness of flexible spectral imaging color enhancement for the detection and diagnosis of small intestinal lesions found by capsule endoscopy.

    PubMed

    Konishi, Masae; Shibuya, Tomoyoshi; Mori, Hiroki; Kurashita, Erina; Takeda, Tsutomu; Nomura, Osamu; Fukuo, Yuka; Matsumoto, Kenshi; Sakamoto, Naoto; Osada, Taro; Nagahara, Akihito; Ogihara, Tatsuo; Watanabe, Sumio

    2014-04-01

    Capsule endoscopy (CE) is an established technique for the detection and diagnosis of obscure gastrointestinal bleeding (OGIB). Flexible spectral imaging color enhancement (FICE) is a software feature of RAPID 6.5. This study assessed the value of FICE for accurate identification of red lesions during CE. We randomly selected 10 patients who underwent CE for OGIB at Juntendo University. The CE images were read by five endoscopists. Small bowel videos, which were recorded by regular CE devices (PillCam SB2, Given Imaging), were evaluated on RAPID 6.5. We standardized the reading condition to a dual view, at a speed of 20 frames/s in manual mode. This interpreted FICE-CE images obtained at settings 1-3. Both conventional and FICE images were read at random. We defined a conventional image as standard and investigated the potential of FICE in detecting small intestinal lesions by the Steel-Dwass test. We considered that conventional images represented baseline (100). On this basis, detection rates for FICE images were as follows: FICE1 = 266.4 ± 33.1 (p < 0.0001); FICE2 = 255.4 ± 25.6 (p < 0.0001); and FICE3 = 117.0 ± 12.3 (p = 0.9447). Detection rates using FICE1 and FICE2 images were significantly higher than conventional CE images. FICE1 and FICE2 were more useful in detecting erosions than conventional CE (p < 0.0001) and FICE3 (p < 0.0001). FICE-CE has a high level of visibility by transparentizing bile or enhancing the color difference associated with reddish mucosa. We found that FICE-CE images were useful in the diagnosing of small intestinal lesions.

  14. Famous endoscopy quotes.

    PubMed

    Cappell, Mitchell S

    2012-01-01

    These quotations, whether humorous or serious, provide insight into how gastroenterology nurses, gastroenterologists, and endoscopists feel about themselves as professionals, how other healthcare professionals perceive them, and their image in popular culture. Recognition of these aspects of gastroenterology nursing, gastroenterology, and endoscopy are important for self-improvement, correcting public misperceptions, and appreciating how patient misperceptions about gastroenterology nurses and gastroenterologists and patient attitudes toward endoscopy may present barriers that gastroenterology professionals must overcome to improve patient care. These quotations also fulfill a need for witticisms during dry endoscopy lectures!

  15. Flexible and transparent gastric battery: energy harvesting from gastric acid for endoscopy application.

    PubMed

    Mostafalu, Pooria; Sonkusale, Sameer

    2014-04-15

    In this paper, we present the potential to harvest energy directly from the digestive system for powering a future wireless endoscopy capsule. A microfabricated electrochemical cell on flexible parylene film is proposed as a gastric battery. This electrochemical cell uses gastric juice as a source of unlimited electrolyte. Planar fabricated zinc [Zn] and palladium [Pd] electrodes serve as anode and cathode respectively. Due to planar geometry, no separator is needed. Moreover the annular structure of the electrodes provides lower distance between cathode and anode reducing the internal resistance. Both electrodes are biocompatible and parylene provides flexibility to the system. For a surface area of 15 mm(2), 1.25 mW is generated which is sufficient for most implantable endoscopy applications. Open circuit output voltage of this battery is 0.75 V. Since this gastric battery does not require any external electrolyte, it has low intrinsic weight, and since it is flexible and is made of biocompatible materials, it offers a promising solution for power in implantable applications. © 2013 Published by Elsevier B.V.

  16. Endoscopy: MedlinePlus Health Topic

    MedlinePlus

    ... What Is Endoscopy? (American Cancer Society) Also in Spanish Related Issues Ensuring the Safety of Your Endoscopic Procedure (American Society for Gastrointestinal Endoscopy) Also in Spanish Sedation for Your Endoscopy (American College of Gastroenterology) ...

  17. Risk of capsule endoscope retention in pediatric patients: a large single-center experience and review of the literature.

    PubMed

    Atay, Orhan; Mahajan, Lori; Kay, Marsha; Mohr, Franziska; Kaplan, Barbara; Wyllie, Robert

    2009-08-01

    Capsule retention is a potential complication of capsule endoscopy (CE). The aims of our study were to determine the incidence of capsule retention in pediatric patients undergoing CE and to identify potential risk factors for capsule retention. We performed an institutional review board-approved retrospective chart review of pediatric patients undergoing CE studies at a single center. Data collected included patient age, sex, prior diagnosis of inflammatory bowel disease (IBD), CE indication, prior small bowel series results, study result, and complications. Two hundred seven CE procedures were performed in pediatric patients during the study period. Capsule retention occurred in 3 (1.4%) of the 207 studies. All 3 patients had known Crohn disease (CD). The risk of capsule retention in pediatric patients with known IBD was 5.2% (3/58). The risk of capsule retention for patients with suspected IBD and all other indications was 0%. If small bowel disease was identified on upper gastrointestinal series in patients with known CD, then the risk of capsule retention was 37.5% (3/8). Only 7 patients with known IBD had a body mass index (BMI) below the 5th percentile. Of these 7 patients, 3 (43%) had capsule retention. Red flags for potential CE retention identified in our study include known IBD (5.2% retention risk), previous small bowel follow-through demonstrating small bowel CD (37.5% retention risk), and BMI <5th percentile with known IBD (43% retention risk). Caution is advised in these pediatric patients before capsule ingestion.

  18. Development of CMOS Imager Block for Capsule Endoscope

    NASA Astrophysics Data System (ADS)

    Shafie, S.; Fodzi, F. A. M.; Tung, L. Q.; Lioe, D. X.; Halin, I. A.; Hasan, W. Z. W.; Jaafar, H.

    2014-04-01

    This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5V to 3.3V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5V to 3.3V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.

  19. Wireless power and data transmission strategies for next-generation capsule endoscopes

    NASA Astrophysics Data System (ADS)

    Puers, R.; Carta, R.; Thoné, J.

    2011-05-01

    Capsular endoscopy is becoming increasingly popular as an alternative to traditional gastro-intestinal (GI) examination techniques. However, the breakthrough of these devices is hindered by the limited amount of power that can be stored in a tiny pill. Most commercial devices use two watch batteries that can only provide an average power of 25 mW for about 6 h, certainly not sufficient for advanced robotic features. A dedicated inductive powering system, operating at 1 MHz to limit the human body absorption, has been developed which was proven to support the transfer of over 300 mW. The system relies on a condensed set of orthogonal ferrite coils, embedded in the capsule, and an external unit based on a Helmholtz coil driven by a class E amplifier. Control data can be sent through the inductive link by modulating the power carrier, whereas a dedicated high data rate RF link is used to transfer the images from the capsule to the base station. Besides evaluating the compatibility with radio transmission, several demonstrators were assembled combining the wireless powering system with various locomotion strategies and LED illumination. This paper describes the design and implementation of the inductive powering system, its combination with data transmission techniques and the testing activity with other capsule-dedicated modules.

  20. Canadian Association of Gastroenterology consensus guidelines on safety and quality indicators in endoscopy

    PubMed Central

    Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dubé, Catherine; Enns, Robert; Hollingworth, Roger; MacIntosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J; Valori, Roland

    2012-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. OBJECTIVE: To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. METHODS: A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. RESULTS: Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. DISCUSSION: The consensus process identified a clear need for high-quality clinical and outcomes research to support quality

  1. Accuracy, safety, and tolerability of tissue collection by Cytosponge vs endoscopy for evaluation of eosinophilic esophagitis.

    PubMed

    Katzka, David A; Geno, Debra M; Ravi, Anupama; Smyrk, Thomas C; Lao-Sirieix, Pierre; Miremadi, Ahmed; Miramedi, Ahmed; Debiram, Irene; O'Donovan, Maria; Kita, Hirohito; Kephart, Gail M; Kryzer, Lori A; Camilleri, Michael; Alexander, Jeffrey A; Fitzgerald, Rebecca C

    2015-01-01

    Management of eosinophilic esophagitis (EoE) requires repeated endoscopic collection of mucosal samples to assess disease activity and response to therapy. An easier and less expensive means of monitoring of EoE is required. We compared the accuracy, safety, and tolerability of sample collection via Cytosponge (an ingestible gelatin capsule comprising compressed mesh attached to a string) with those of endoscopy for assessment of EoE. Esophageal tissues were collected from 20 patients with EoE (all with dysphagia, 15 with stricture, 13 with active EoE) via Cytosponge and then by endoscopy. Number of eosinophils/high-power field and levels of eosinophil-derived neurotoxin were determined; hematoxylin-eosin staining was performed. We compared the adequacy, diagnostic accuracy, safety, and patient preference for sample collection via Cytosponge vs endoscopy procedures. All 20 samples collected by Cytosponge were adequate for analysis. By using a cutoff value of 15 eosinophils/high power field, analysis of samples collected by Cytosponge identified 11 of the 13 individuals with active EoE (83%); additional features such as abscesses were also identified. Numbers of eosinophils in samples collected by Cytosponge correlated with those in samples collected by endoscopy (r = 0.50, P = .025). Analysis of tissues collected by Cytosponge identified 4 of the 7 patients without active EoE (57% specificity), as well as 3 cases of active EoE not identified by analysis of endoscopy samples. Including information on level of eosinophil-derived neurotoxin did not increase the accuracy of diagnosis. No complications occurred during the Cytosponge procedure, which was preferred by all patients, compared with endoscopy. In a feasibility study, the Cytosponge is a safe and well-tolerated method for collecting near mucosal specimens. Analysis of numbers of eosinophils/high-power field identified patients with active EoE with 83% sensitivity. Larger studies are needed to establish the

  2. The risk of retention of the capsule endoscope in patients with known or suspected Crohn's disease.

    PubMed

    Cheifetz, Adam S; Kornbluth, Asher A; Legnani, Peter; Schmelkin, Ira; Brown, Alphonso; Lichtiger, Simon; Lewis, Blair S

    2006-10-01

    Capsule endoscopy (CE) allows visualization of the mucosa of the entire small bowel and is therefore a potentially important tool in the evaluation of patients with known or suspected Crohn's disease (CD). However, small bowel strictures, which are not uncommon in Crohn's, are considered to be a contraindication to CE for fear of capsule retention. Our goal was to determine the risk of capsule retention in patients with suspected or known CD. We retrospectively reviewed the records of 983 CE cases performed at three private gastroenterology practices between December 2000 and December 2003, and selected those with suspected or proven Crohn's. A total of 102 cases were identified in which CE was used in patients with suspected (N = 64) or known (N = 38) CD. Only one of 64 patients (1.6%) with suspected CD had a retained capsule. However, in five of 38 (13%) patients with known Crohn's, the capsule was retained proximal to a stricture. Of the five cases of retained capsules, three strictures were previously unknown. In four cases, the obstructing lesions were resected without complications, leading to complete resolution of the patient's underlying symptoms. One patient chose not to undergo surgery and has remained without an episode of small bowel obstruction for over 38 months. Capsule retention occurred in 13% (95% CI 5.6%-28%) of patients with known CD, but only in 1.6% (95% CI 0.2%-10%) with suspected Crohn's. A retained capsule may indicate unsuspected strictures in Crohn's that may require an unexpected, but therapeutic, surgical intervention. Patients and physicians should be aware of these potential risks when using CE in CD.

  3. Contact Endoscopy of mucosal lesions of oral cavity – Preliminary experience

    PubMed Central

    Mishra, Awadhesh Kumar; Nilakantan, Ajith; Sahai, Kavita; Datta, Rakesh; Malik, Ajay

    2014-01-01

    Background Contact Endoscopy is a non invasive tool to visualise alterations in cell architecture in vivo. In this study we investigated the diagnostic accuracy of Contact Endoscopy in detecting malignancy in oral mucosal lesions. Methods 76 patients with oral mucosal lesions requiring biopsy were included. Contact Endoscopy was performed by Otolaryngologist before biopsy and findings recorded. The lesion was then biopsied and sent for histopathological examination by Pathologist who was blinded to Contact Endoscopy findings. Findings of Contact Endoscopy were compared with histopathological findings taking the latter as the gold standard. Two biopsies were reported as ‘inconclusive’ on histopathological examination and hence excluded from the final analysis. Data of the remaining 74 patients is presented here. Results Clinically lesions were diagnosed as ulcero-proliferative lesions in 34 patients, Leukoplakia in 19, Erythroplakia in 9, Lichen planus in 5 and Submucous fibrosis in 7 patients. Histopathological examination revealed presence of malignancy in 97.06% of ulcero-proliferative mucosal lesions, 10.53% of leukoplakia and 33.33% of erythroplakia while corresponding figures on Contact Endoscopy were 94.12%, 5.26% and 11.11% respectively. No malignancy was detected in lichen planus and submucous fibrosis by either technique. When compared with histopathological examination, CE showed sensitivity of 84.21%, specificity of 94.44% and accuracy of 89.19%. No adverse effects on the patients were seen due to the procedure or stain. Conclusion Contact Endoscopy may be useful in determining cellular structure in vivo without biopsy to detect oral malignancy early. Further studies are suggested. PMID:25378780

  4. Factors associated with attendance to scheduled outpatient endoscopy

    PubMed Central

    Laiyemo, Adeyinka O.; Williams, Carla D.; Burnside, Clinton; Moghadam, Sepideh; Sanasi-Bhola, Kamla D.; Kwagyan, John; Brim, Hassan; Ashktorab, Hassan; Scott, Victor F.; Smoot, Duane T.

    2015-01-01

    Background Non-attendance of 42% has been reported for outpatient colonoscopy among persons with low socioeconomic status (SES) in an open access system in the United States. Objectives To evaluate attendance to outpatient endoscopy among populations with low SES after in-person consultations with endoscopists prior to scheduling. Methods Retrospectively, we reviewed the endoscopy schedule from September 2009 to August 2010 in an inner city teaching hospital in Washington DC. We identified patients who came for their procedures. We defined non-attendance as when patients did not notify the facility up to 24 hours prior to their scheduled procedures and did not show up . Results A total of 3,304 patients were scheduled for outpatient endoscopy (mean age 55.2 years; 59.5% females). Only 36 (1.1%) patients were uninsured. 716 (21.7%) patients did not show up for their procedures. There were no differences in attendance by age, sex and race. Patients seen in a private endoscopist's office (OR=1.47; 95%CI: 1.07–2.04) were more likely to attend when compared to patients seen in trainees’ continuity clinic. Married patients (OR=1.40; 95%CI: 1.11–1.78) were also more likely to attend. Conversely, Medicaid and uninsured patients were less likely to attend. Restricting our analysis to patients scheduled for only colonoscopy yielded similar results except that patients who were 50 years and older were more likely to attend. Conclusions Our study suggests improved attendance to endoscopy when populations with lower SES undergo prior consultation with an endoscopist. There is a potential to further improve attendance to out-patient endoscopy by directly involving the social support of the patients. PMID:25180285

  5. Quality Improvement in Pediatric Endoscopy: A Clinical Report From the NASPGHAN Endoscopy Committee.

    PubMed

    Kramer, Robert E; Walsh, Catharine M; Lerner, Diana G; Fishman, Douglas S

    2017-07-01

    The current era of healthcare reform emphasizes the provision of effective, safe, equitable, high-quality, and cost-effective care. Within the realm of gastrointestinal endoscopy in adults, renewed efforts are in place to accurately define and measure quality indicators across the spectrum of endoscopic care. In pediatrics, however, this movement has been less-defined and lacks much of the evidence-base that supports these initiatives in adult care. A need, therefore, exists to help define quality metrics tailored to pediatric practice and provide a toolbox for the development of robust quality improvement (QI) programs within pediatric endoscopy units. Use of uniform standards of quality reporting across centers will ensure that data can be compared and compiled on an international level to help guide QI initiatives and inform patients and their caregivers of the true risks and benefits of endoscopy. This report is intended to provide pediatric gastroenterologists with a framework for the development and implementation of endoscopy QI programs within their own centers, based on available evidence and expert opinion from the members of the NASPGHAN Endoscopy Committee. This clinical report will require expansion as further research pertaining to endoscopic quality in pediatrics is published.

  6. Training the gastrointestinal endoscopy trainer.

    PubMed

    Waschke, Kevin A; Anderson, John; Macintosh, Donald; Valori, Roland M

    2016-06-01

    Endoscopy training has traditionally been accomplished by an informal process in the endoscopy unit that parallels apprenticeship training seen in other areas of professional education. Subsequent to an audit, a series of interventions were implemented in the English National Health Service to support both service delivery and to improve endoscopy training. The resulting training centers deliver a variety of hands-on endoscopy courses, established in parallel with the roll out of a colon cancer screening program that monitors and documents quality outcomes among endoscopists. The program developed a 'training the trainer' module that subsequently became known as the Training the Colonoscopy Trainer course (TCT). Several years after its implementation, colonoscopy quality outcomes in the UK have improved substantially. The core TCT program has spread to other countries with demonstration of a marked impact on endoscopy training and performance. The aim of this chapter is to describe the principles that underlie effective endoscopy training in this program using the TCT as an example. While the review focuses on the specific example of colonoscopy training, the approach is generic to the teaching of any technical skill; it has been successfully transferred to the teaching of laparoscopic surgery as well as other endoscopic techniques. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Influence of capsule shell composition on the performance indicators of hypromellose capsule in comparison to hard gelatin capsules.

    PubMed

    Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani

    2015-01-01

    The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.

  8. Videoscopic Heller Myotomy with Intraoperative Endoscopy Promotes Optimal Outcomes

    PubMed Central

    Bloomston, Mark; Brady, Patrick

    2002-01-01

    Background and Objectives: Minimally invasive surgical techniques are applicable to achalasia, but the optimum approach to intraoperative assessment of adequacy of myotomy remains unestablished. We set out to show that videoscopic Heller myotomy with concurrent endoscopy ensures adequacy of myotomy while limiting postoperative clinically apparent reflux. Methods: Seventy-eight consecutive patients with achalasia underwent videoscopic Heller myotomy with concomitant endoscopy between 1992 and 1998. Fundoplication was not routinely undertaken. Results: Preoperative symptoms consisted of dysphagia (100%), emesis/regurgitation (68%), heartburn (58%), and postprandial chest pain (49%). Following myotomy, significant improvement (P < 0.0001) was seen in dysphagia (43%), postprandial chest pain (13%), and emesis/regurgitation (9%) at a mean follow-up of 33 ± 2.2 months. Mean reflux score (scale 0 to 5) improved from 3.7 ± 0.3 to 1.5 ± 0.2 (P < 0.0001). Improvement in symptoms was reported in 96% of patients. Fundoplication was used in 8 patients as part of hiatus reconstruction (n = 6) or repair of esophageal perforation (n = 2). Conclusions: Intraoperative endoscopy during video-scopic Heller myotomy guides the extent and adequacy of myotomy. By utilizing a focused dissection with preservation of the natural antireflux mechanisms around the gastroesophageal junction and limiting the extent of myotomy along the cardia, postoperative reflux symptoms are minimized. We advocate concomitant endoscopy during Heller myotomy to guide myotomy and submit that routine fundoplication is clinically unnecessary. PMID:12113416

  9. Job Stress and Job Satisfaction among Health-Care Workers of Endoscopy Units in Korea

    PubMed Central

    Nam, Seung-Joo; Chun, Hoon Jai; Moon, Jeong Seop; Park, Sung Chul; Hwang, Young-Jae; Yoo, In Kyung; Lee, Jae Min; Kim, Seung Han; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Background/Aims: The management of job-related stress among health-care workers is critical for the improvement of healthcare services; however, there is no existing research on endoscopy unit workers as a team. Korea has a unique health-care system for endoscopy unit workers. In this study, we aimed to estimate job stress and job satisfaction among health-care providers in endoscopy units in Korea. Methods: We performed a cross-sectional survey of health-care providers in the endoscopy units of three university-affiliated hospitals in Korea. We analyzed the job stress levels by using the Korean occupational stress scale, contributing factors, and job satisfaction. Results: Fifty-nine workers completed the self-administered questionnaires. The job stress scores for the endoscopy unit workers (46.39±7.81) were relatively lower compared to those of the national sample of Korean workers (51.23±8.83). Job stress differed across job positions, with nurses showing significantly higher levels of stress (48.92±7.97) compared to doctors (42.59±6.37). Job stress and job satisfaction were negatively correlated with each other (R2=0.340, p<0.001). Conclusions: An endoscopy unit is composed of a heterogeneous group of health-care professionals (i.e., nurses, fellows, and professors), and job stress and job satisfaction significantly differ according to job positions. Job demand, insufficient job control, and job insecurity are the most important stressors in the endoscopy unit. PMID:26898513

  10. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    PubMed

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  11. WEO position statement on hygiene in digestive endoscopy: Focus on endoscopy units in Asia and the Middle East.

    PubMed

    Murdani, Abdullah; Kumar, Ajay; Chiu, Han-Mo; Goh, Khean-Lee; Jang, Byung Ik; Khor, Christopher J L; Lau, James; Mostafa, Ibrahim; Ramchandani, Mohan; Ratanalert, Siriporn; Tajiri, Hisao; Yuen, Minghwa; Zhang, Shu Tian; Duforest-Rey, Dianelle; Rey, Jean-Francois

    2017-01-01

    The aim of this position statement is to reinforce the key points of hygiene in digestive endoscopy. The present article details the minimum hygiene requirements for reprocessing of endoscopes and endoscopic devices, regardless of the reprocessing method (automated washer-disinfector or manual cleaning) and the endoscopy setting (endoscopy suite, operating room, elective or emergency procedures). These minimum requirements are mandatory for patient safety. Both advanced diagnostic and therapeutic endoscopies should be carried out in an environment that is safe for patients and staff. Particular attention is given to contaminants. Procedural errors in decontamination, defective equipment, and failure to follow disinfection guidelines are major factors contributing to transmission of infection during endoscopy. Other important risk factors include inadequate cleaning, use of older endoscopes with surface and working channel irregularities, and contamination of water bottles or irrigating solutions. Infections by multidrug-resistant organisms have become an increasing problem in health-care systems worldwide. Since 2010, outbreaks of multidrug-resistant bacteria associated with endoscopic retrograde cholangiopancreatography have been reported from the USA, France, Germany, and The Netherlands. In many endoscopy units in Asia and the Middle East, reprocessing procedures have lagged behind those of Western countries for cultural reasons or lack of financial resources. This inconsistency in standards is now being addressed, and the World Endoscopy Organization has prepared this position statement to highlight key points for quality assurance in any endoscopy unit in any country. © 2016 Japan Gastroenterological Endoscopy Society.

  12. Clinical experience using the tethered capsule-based spectrally encoded confocal microendoscopy for diagnosis of eosinophilic esophagitis (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Do, Dukho; Alali, Sanaz; Kang, DongKyun; Tabatabaie, Nima; Lu, Weina; Grant, Catriona N.; Soomro, Amna R.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.

    2016-03-01

    Eosinophilic Esophagitis (EoE) is caused by food allergies, and defined by histological presence of eosinophil cells in the esophagus. The current gold standard for EoE diagnosis is endoscopy with pinch biopsy to detect more than 15 eosinophils/ High power field (HPF). Biopsy examinations are expensive, time consuming and are difficult to tolerate for patients. Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology capable of imaging individual eosinophils as highly scattering cells (diameter between 8 µm to 15 µm) in the epithelium. Our lab has developed a tethered SECM capsule that can be swallowed by unsedated patients. The capsule acquires large area confocal images, equivalent to more than 30,000 HPFs, as it traverses through the esophagus. In this paper, we present the outcome of a clinical study using the tethered SECM capsule for diagnosing EoE. To date, 32 subjects have been enrolled in this study. 88% of the subjects swallowed the capsules without difficulty and of those who swallowed the capsule, 95% preferred the tethered capsule imaging procedure to sedated endoscopic biopsy. Each imaging session took about 12 ± 2.4 minutes during which 8 images each spanning of 24 ± 5 cm2 of the esophagus were acquired. SECM images acquired from EoE patients showed abundant eosinophils as highly scattering cells in squamous epithelium. Results from this study suggest that the SECM capsule has the potential to become a less-invasive, cost-effective tool for diagnosing EoE and monitoring the response of this disease to therapy.

  13. Novel disposable transnasal endoscopy for assessment of esophageal motor function.

    PubMed

    Lim, Chul-Hyun; Choi, Myung-Gyu; Baeg, Myong-Ki; Moon, Sung Jin; Kim, Jin Su; Cho, Yu Kyung; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong

    2014-01-01

    A novel disposable transnasal endoscopy (DTE) with a portable system has been developed to provide unsedated esophagoscopy by modifying capsule endoscopy. The aim of this study was to assess the feasibility of DTE to evaluate esophageal motor function. Patients with or suspected esophageal motility disorders and healthy volunteers were enrolled. Participants underwent esophageal high-resolution manometry and DTE in random order on different days. Motility was observed with DTE at 1, 8, and 16 cm above the gastroesophageal junction. Twenty healthy volunteers and 20 symptomatic subjects participated (8 achalasia, 5 scleroderma, 3 diffuse esophageal spasm, 1 hypertensive peristalsis, 1 peristaltic dysfunction, and 22 normal esophageal function). The normal findings on DTE were as follows. As the subject swallowed water, swallow-induced relaxation with elevation of the lower esophageal sphincter caused the endoscope to cross the Z-line into the gastric lumen. After the passage of water and air, complete closure of the lower esophageal sphincter occurred, with the return of the endoscope to its previous position. During the resting stage of the esophageal body, an air bubble could be seen in the center of the radially wrinkled and occluded lumen. The endoscopic diagnosis was in agreement with the clinical diagnosis in all but 2. Most of the participants reported acceptable discomfort during DTE and 62.5% of the subjects preferred DTE to manometry. DTE can accurately characterize normal esophageal motor function, allowing the diagnosis of esophageal motility disorders. DTE has potential widespread applications, especially in outpatient clinics.

  14. Quality assurance for gastrointestinal endoscopy.

    PubMed

    Allen, John I

    2012-09-01

    This review concerns quality assurance for gastrointestinal endoscopic procedures, especially colonoscopy and will emphasize research and guidelines published since January 2011. Important articles from previous years have been included for background. Critical lapses in endoscope processing and administration of intravenous sedation alerted us to the infection risk of endoscopy. Increases in cost of colonoscopy, evidence for overuse and studies demonstrating missed cancers have led some to question the value of endoscopy. Despite these setbacks, the National Polyp Study (NPS) consortium published their long-term follow-up of the original NPS patients and confirmed that colonoscopy with polyp removal can reduce the risk of colorectal cancer for an extended period. In this article, we will focus on ways to improve the value of outpatient colonoscopy. The United States national quality improvement agenda recently became organized into a more coordinated effort spearheaded by several public and private entities. They comprise the infrastructure by which performance measures are developed and implemented as accountability standards. Understanding wherein a gastroenterology (GI) practice fits into this infrastructure and learning ways we can improve our endoscopic practice is important for physicians who provide this vital service to patients. This article will provide a roadmap for developing a quality assurance program for endoscopic practice.

  15. Feasibility and safety of a novel magnetic-assisted capsule endoscope system in a preliminary examination for upper gastrointestinal tract.

    PubMed

    Lien, Gi-Shih; Wu, Ming-Shun; Chen, Chun-Nan; Liu, Chih-Wen; Suk, Fat-Moon

    2018-04-01

    Current capsule endoscopy procedures are ineffective for upper gastrointestinal (GI) tract examination because they do not allow for operator-controlled navigation of the capsule. External controllability of a capsule endoscope with an applied magnetic field is a possible solution to this problem. We developed a novel magnetic-assisted capsule endoscope (MACE) system to visualize the entire upper GI tract. The present study evaluated the safety and feasibility of the MACE system for the examination of the upper GI tract, including the esophagus, stomach, and duodenum. The present open clinical study enrolled ten healthy volunteers. All participants swallowed a MACE, and an external magnetic field navigator was used for magnetic capsule manipulation in the upper GI tract. We assessed the maneuverability of the magnetic capsule and completeness of the MACE examination as well as the safety and tolerability of the procedure. The present study enrolled ten healthy volunteers with a mean age and body mass index of 47.7 years and 25.6 kg/m 2 , respectively. One volunteer withdrew because of difficulty in swallowing the capsule. In total, nine volunteers underwent the MACE examination. The average examination time was 27.1 min. The maneuverability of the capsule was assessed as good and fair in 55.6 and 44.4% of the participants, respectively. The overall completeness of the examination in the esophagus, stomach, and duodenum was 100, 85.2, and 86.1%, respectively. No severe adverse events occurred during this study. All participants exhibited satisfactory tolerance of the MACE examination. The MACE system has satisfactory maneuverability and visualization completeness with excellent acceptance and tolerance.

  16. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    PubMed

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  17. Perforation following colorectal endoscopy: what happens beyond the endoscopy suite?

    PubMed

    Tam, Michael S; Abbas, Maher A

    2013-01-01

    The risk factors for perforation from colorectal endoscopy have been well studied, but little is known about clinical outcomes beyond the immediate event. To evaluate short- and long-term outcomes of iatrogenic colorectal perforation following colorectal endoscopy. Retrospective review over 16 years at a single tertiary care institution. Treatment interventions, morbidity and mortality rates, hospital length of stay, stoma closure rate, and long-term complications. Of 132,259 colorectal endoscopies, 26 patients (0.02%) had a perforation (54% males; mean age, 67 years). The rectosigmoid colon was the most common site of perforation (65%). Thirty-eight percent of the perforations were recognized at the time of procedure, 31% presented within 24 hours, and 31% presented beyond 24 hours. Operative repair was undertaken in 85% of the patients, and 15% were managed with inpatient hospital observation. Primary repair was performed in 68% (defunctioning stoma in 18%). Mean hospital length of stay was 10.1 days. The overall postoperative complications rate was 55%, and wound complications were noted in 45%. The 30-day mortality rate was 19%. No death was observed beyond the first month. American Society of Anesthesiologists physical status Classes 3 and 4 were associated with mortality (p = 0.004). Of 7 patients who received a stoma, only 2 patients (29%) had stoma reversal. Long-term complications included incisional hernia (10%) and small-bowel obstruction (5%). Perforation following colorectal endoscopy was uncommon in this study but was associated with significant morbidity and mortality. An increased risk of death was noted with higher American Society of Anesthesiologists physical status class.

  18. Impact of demographic and clinical parameters on video capsule transit time.

    PubMed

    Niv, Eva; Pinchasovich, Hadassa; Yanai, Henit

    2016-10-01

    Small bowel (SB) capsule endoscopy (CE) studies provide data on both gastric and SB transit times (GTT and SBTT, respectively). This study aimed to evaluate the influence of demographic and clinical parameters on the GTT and SBTT. Transit times for two generations of capsules (Pillcam SB2 and SB3) were also compared. Consecutive adult patients undergoing CE were included. GTT, SBTT, and cecum arrival rates were calculated and correlated to demographics and clinical characteristics. A total of 332 CE studies were analyzed. Neither GTT nor SBTT were impacted by age or sex. SBTT was prolonged in newly diagnosed Crohn's disease (CD) patients compared with all other patients (303.1±90.3 vs. 243.6±83.6 min, P=0.02 for SB2, 267.8±63 vs. 228.6±72.3, P=0.01 for SB3, respectively). Moreover, CD patients had higher incomplete study rates compared with patients with all other diagnoses (29.4 vs. 7.3%, respectively, P=0.0116) in the SB2 subgroup. Higher cecum arrival rates were achieved by the SB3 capsule compared with SB2 (97 vs. 91%, P=0.04). Patients with prolonged gastric time or patients with incomplete studies had similar demographic and clinical characteristics as others. Age and sex apparently do not influence intestinal kinetics. Newly diagnosed CD patients have relatively prolonged SBTTs. Demographic and clinical parameters cannot predict prolonged GTT or cecum nonarrival.

  19. Automated segmentation and characterization of esophageal wall in vivo by tethered capsule optical coherence tomography endomicroscopy

    PubMed Central

    Ughi, Giovanni J.; Gora, Michalina J.; Swager, Anne-Fré; Soomro, Amna; Grant, Catriona; Tiernan, Aubrey; Rosenberg, Mireille; Sauk, Jenny S.; Nishioka, Norman S.; Tearney, Guillermo J.

    2016-01-01

    Optical coherence tomography (OCT) is an optical diagnostic modality that can acquire cross-sectional images of the microscopic structure of the esophagus, including Barrett’s esophagus (BE) and associated dysplasia. We developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires high-resolution images of entire gastrointestinal (GI) tract luminal organs. This device has a potential to become a screening method that identifies patients with an abnormal esophagus that should be further referred for upper endoscopy. Currently, the characterization of the OCT-TCE esophageal wall data set is performed manually, which is time-consuming and inefficient. Additionally, since the capsule optics optimally focus light approximately 500 µm outside the capsule wall and the best quality images are obtained when the tissue is in full contact with the capsule, it is crucial to provide feedback for the operator about tissue contact during the imaging procedure. In this study, we developed a fully automated algorithm for the segmentation of in vivo OCT-TCE data sets and characterization of the esophageal wall. The algorithm provides a two-dimensional representation of both the contact map from the data collected in human clinical studies as well as a tissue map depicting areas of BE with or without dysplasia. Results suggest that these techniques can potentially improve the current TCE data acquisition procedure and provide an efficient characterization of the diseased esophageal wall. PMID:26977350

  20. Tethered SECM endoscopic capsule for the diagnosis of eosinophilic esophagitis (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Do, Dukho; Kang, DongKyun; Tabatabaei, Nima; Grant, Catriona N.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.

    2017-02-01

    Eosinophilic Esophagitis (EoE) is an inflammatory disease caused by inhaled or ingested food allergies, and characterized by the infiltration of eosinophils in the esophagus. The gold standard for diagnosing EoE is to conduct endoscopy and obtain multiple biopsy specimens from different portions of the esophagus; an exam is considered positive if more than 15 eosinophils per high power field (HPF) in any of the biopsies. This method of diagnosis is problematic because endoscopic biopsy is expensive and poorly tolerated and the esophageal eosinophil burden needs to be monitored frequently during the course of the disease. Spectrally encoded confocal microscopy (SECM) is a high-speed confocal microscopy technology that can visualize individual eosinophils in large microscopic images of the human esophagus, equivalent to more than 30,000 HPF. Previously, we have demonstrated that tethered capsule SECM can be conducted in unsedated subjects with diagnosed EoE. However, speckle noise and the relatively low resolution in images obtained with the first capsule prototypes made it challenging to distinguish eosinophils from other cells. In this work, we present a next-generation tethered SECM capsule, which has been modified to significantly improve image quality. First, we substituted the single mode fiber with a dual-clad fiber to reduce speckle noise. A gradient-index multimode fiber was fusion spliced at the tip of the dual-clad fiber to increase the effective numerical aperture of the fiber from 0.09 to 0.15, expanding the beam more rapidly to increase the illumination aperture at the objective. These modifications enabled the new SECM capsule to achieve a lateral resolution of 1.8 µm and an axial resolution of 16.1 µm, which substantially improves the capacity of this probe to visualize cellular features in human tissue. The total size of the SECM capsule remained 6.75 mm in diameter and 31 mm in length. We are now in the process of testing this new SECM capsule in

  1. Transnasal endoscopy: no gagging no panic!

    PubMed Central

    Parker, Clare; Alexandridis, Estratios; Plevris, John; O'Hara, James; Panter, Simon

    2016-01-01

    Background Transnasal endoscopy (TNE) is performed with an ultrathin scope via the nasal passages and is increasingly used. This review covers the technical characteristics, tolerability, safety and acceptability of TNE and also diagnostic accuracy, use as a screening tool and therapeutic applications. It includes practical advice from an ear, nose, throat (ENT) specialist to optimise TNE practice, identify ENT pathology and manage complications. Methods A Medline search was performed using the terms “transnasal”, “ultrathin”, “small calibre”, “endoscopy”, “EGD” to identify relevant literature. Results There is increasing evidence that TNE is better tolerated than standard endoscopy as measured using visual analogue scales, and the main area of discomfort is nasal during insertion of the TN endoscope, which seems remediable with adequate topical anaesthesia. The diagnostic yield has been found to be similar for detection of Barrett's oesophagus, gastric cancer and GORD-associated diseases. There are some potential issues regarding the accuracy of TNE in detecting small early gastric malignant lesions, especially those in the proximal stomach. TNE is feasible and safe in a primary care population and is ideal for screening for upper gastrointestinal pathology. It has an advantage as a diagnostic tool in the elderly and those with multiple comorbidities due to fewer adverse effects on the cardiovascular system. It has significant advantages for therapeutic procedures, especially negotiating upper oesophageal strictures and insertion of nasoenteric feeding tubes. Conclusions TNE is well tolerated and a valuable diagnostic tool. Further evidence is required to establish its accuracy for the diagnosis of early and small gastric malignancies. There is an emerging role for TNE in therapeutic endoscopy, which needs further study. PMID:28839865

  2. Less Is More: A Minimalist Approach to Endoscopy.

    PubMed

    Shaheen, Nicholas J; Fennerty, M Brian; Bergman, Jacques J

    2018-05-01

    A substantial literature documents inappropriate usage of gastrointestinal endoscopy in a variety of clinical settings. Overusage of endoscopy appears to be common, and 30% or more of procedures performed in some clinical settings have questionable indications. The potential reasons for overuse of endoscopy are multiple, and include cancer phobia, fear of medical malpractice litigation, profit motive, the investigation of "incidentalomas" found on other imaging, and underappreciation of the delayed harms of endoscopy, among other reasons. Clinical guidelines, which should limit overuse of endoscopy, may instead serve to promote it, if authors opt to be "conservative," recommending endoscopy in situations of unclear utility. Several strategies may decrease overuse of endoscopy, including careful attention to risk stratification when choosing patients to screen, adherence to guidelines for surveillance intervals for colonoscopy, the use of quality indicators to identify outliers in endoscopy utilization, and education on appropriate indications and the risks of overuse at the medical student, residency, and fellowship levels. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy.

    PubMed

    Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S

    2016-06-01

    Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Performance measures for lower gastrointestinal endoscopy: a European Society of Gastrointestinal Endoscopy (ESGE) quality improvement initiative

    PubMed Central

    Thomas-Gibson, Siwan; Bugajski, Marek; Bretthauer, Michael; Rees, Colin J; Dekker, Evelien; Hoff, Geir; Jover, Rodrigo; Suchanek, Stepan; Ferlitsch, Monika; Anderson, John; Roesch, Thomas; Hultcranz, Rolf; Racz, Istvan; Kuipers, Ernst J; Garborg, Kjetil; East, James E; Rupinski, Maciej; Seip, Birgitte; Bennett, Cathy; Senore, Carlo; Minozzi, Silvia; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Spada, Cristiano; Hassan, Cesare; Dinis-Ribeiro, Mario; Rutter, Matthew D

    2017-01-01

    The European Society of Gastrointestinal Endoscopy and United European Gastroenterology present a short list of key performance measures for lower gastrointestinal endoscopy. We recommend that endoscopy services across Europe adopt the following seven key performance measures for lower gastrointestinal endoscopy for measurement and evaluation in daily practice at a center and endoscopist level: 1 rate of adequate bowel preparation (minimum standard 90%); 2 cecal intubation rate (minimum standard 90%); 3 adenoma detection rate (minimum standard 25%); 4 appropriate polypectomy technique (minimum standard 80%); 5 complication rate (minimum standard not set); 6 patient experience (minimum standard not set); 7 appropriate post-polypectomy surveillance recommendations (minimum standard not set). Other identified performance measures have been listed as less relevant based on an assessment of their importance, scientific acceptability, feasibility, usability, and comparison to competing measures. PMID:28507745

  5. Patient Experiences with Surveillance Endoscopy: A Qualitative Study

    PubMed Central

    Arney, Jennifer; Hinojosa-Lindsey, Marilyn; Street, Richard L.; Hou, Jason; El-Serag, Hashem B.; Naik, Aanand D.

    2014-01-01

    Background Prior studies examining patterns of esophagogastroduodenoscopy (EGD) surveillance in patients with Barrett’s Esophagus (BE) demonstrate variable adherence to practice guidelines. In prior studies, memories of endoscopic experiences shaped patients’ overall perceptions and subsequent adherence behaviors, but the specific elements of that experience are unclear. We therefore sought to identify elements of the EGD experience that frame patients’ memories and overall perceptions of surveillance. Methods We conducted structured in-depth, qualitative interviews with BE patients in a single regional medical center. We recruited patients with a range of severity of BE (non-dysplastic, low-grade and high-grade dysplasia) who recently completed an EGD. Data collection continued until we reached thematic saturation (n=20). We applied principles of framework analysis to identify emerging themes regarding patients’ salient EGD experiences. We validated our coding scheme through multidisciplinary consensus meetings comprised of clinician (gastroenterologist and internist) and non-clinician investigators (sociologist and public health expert). Results Patient experiences can be conceptualized within a temporal model of surveillance EGD: prior to endoscopy, during the endoscopy procedure, and after endoscopy. Within this model, the most memorable aspects of the EGD experience include physician-patient communication prior to EGD, wait time at the endoscopy center, interpersonal interactions at the time of the EGD, level of pain or discomfort with the procedure, level of trust in the physician following EGD, and gaining a sense of control over BE. Conclusions We identified six salient memories before, during, and after the procedure that shape patients’ perceptions of the EGD experience. We offer recommendations for measuring the patient experience of EGD using a composite of validated survey items. Future studies should test the relation of patient experience

  6. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    PubMed

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  7. A 13-year time trend analysis of 3724 small bowel video capsule endoscopies and a forecast model during the financial crisis in Greece.

    PubMed

    Triantafyllou, Konstantinos; Gkolfakis, Paraskevas; Viazis, Nikos; Tsibouris, Panagiotis; Tsigaridas, Athanasios; Apostolopoulos, Periklis; Anastasiou, John; Hounda, Eleni; Skianis, Ioannis; Katopodi, Konstantina; Ndini, Xhoela; Alexandrakis, George; Karamanolis, Demetrios G

    2017-02-01

    Since its introduction, small bowel video capsule endoscopy (VCE) use has evolved considerably. Evaluation of the temporal changes of small bowel VCE utilization in three tertiary centers in Greece in Era 1 (2002-2009) and Era 2 (2010-2014) and the development a forecast model for future VCE use during 2015-2017. Data from all small bowel VCE examinations were retrieved and analyzed in terms of the annual number of the performed examinations, their indications and the significance of their findings. Overall, we evaluated 3724 VCE examinations. The number of studies peaked in 2009 (n=595) and then decreased to reach 225 in 2014. Overall, more (53.8 vs. 51.4%) patients with iron-deficiency anemia and obscure gastrointestinal bleeding (IDA/OGIB) and fewer (10.7 vs. 14%) patients with chronic diarrhea were evaluated in Era 2 compared with Era 1 (P=0.046). In Era 2, there were more nondiagnostic examinations (39.5 vs. 29.3%, P<0.001), whereas the rate of cases with relevant findings decreased from 47.8 to 40.9%. According to the time trend analysis, we developed a forecast model with two scenarios: the pessimistic and the optimistic. Validation of the model with 2015 data showed that reality was close to the pessimistic scenario: the number of exams further decreased to 190, studies carried out for IDA/OGIB increased to 67%, and there were more negative than positive exams (40.7 vs. 39.2%). The number of VCE studies carried out after the emergence of the financial crisis decreased significantly and VCE indications were optimized. Our forecast model predicts lower numbers of VCE studies, with IDA/OGIB being the dominant indication. However, the predicted increase of negative exams requires further evaluation.

  8. Leadership and team building in gastrointestinal endoscopy.

    PubMed

    Valori, Roland M; Johnston, Deborah J

    2016-06-01

    A modern endoscopy service delivers high volume procedures that can be daunting, embarrassing and uncomfortable for patients [1]. Endoscopy is hugely beneficial to patients but only if it is performed to high standards [2]. Some consequences of poor quality endoscopy include worse outcomes for cancer and gastrointestinal bleeding, unnecessary repeat procedures, needless damage to patients and even avoidable death [3]. New endoscopy technology and more rigorous decontamination procedures have made endoscopy more effective and safer, but they have placed additional demands on the service. Ever-scarcer resources require more efficient, higher turnover of patients, which can be at odds with a good patient experience, and with quality and safety. It is clear from the demands put upon it, that to deliver a modern endoscopy service requires effective leadership and team working [4]. This chapter explores what constitutes effective leadership and what makes great clinical teams. It makes the point that endoscopy services are not usually isolated, independent units, and as such are dependent for success on the organisations they sit within. It will explain how endoscopy services are affected by the wider policy and governance context. Finally, within the context of the collection of papers in this edition of Best Practice & Research: Clinical Gastroenterology, it explores the potentially conflicting relationship between training of endoscopists and service delivery. The effectiveness of leadership and teams is rarely the subject of classic experimental designs such as randomized controlled trials. Nevertheless there is a substantial literature on this subject within and particularly outside healthcare [5]. The authors draw on this wider, more diffuse literature and on their experience of delivering a Team Leadership Programme (TLP) to the leaders of 70 endoscopy teams during the period 2008-2012. (Team Leadership Programme Link

  9. Staffing levels in endoscopy units.

    PubMed

    Ott, B J; Igo, M; Shields, N

    1994-04-01

    Staffing the endoscopy area has become increasingly complex. Growth in procedure volumes, changes in technology, and the application of endoscopy in the diagnosis and treatment of disease contribute to the complexities. The manager must deal with these changes, maintain costs, and still provide adequate staffing to ensure patient safety and quality care. The purpose of this article is to present the results of a laboratory manager survey conducted in 1990. Of 51 laboratory managers who responded, those who rated their laboratories to be adequately staffed averaged 4.2 hr per procedure. The survey results may be useful to laboratory managers seeking to calculate staff needs in a typical endoscopy area.

  10. Motion analysis for duplicate frame removal in wireless capsule endoscope

    NASA Astrophysics Data System (ADS)

    Lee, Hyun-Gyu; Choi, Min-Kook; Lee, Sang-Chul

    2011-03-01

    Wireless capsule endoscopy (WCE) has been intensively researched recently due to its convenience for diagnosis and extended detection coverage of some diseases. Typically, a full recording covering entire human digestive system requires about 8 to 12 hours for a patient carrying a capsule endoscope and a portable image receiver/recorder unit, which produces 120,000 image frames on average. In spite of the benefits of close examination, WCE based test has a barrier for quick diagnosis such that a trained diagnostician must examine a huge amount of images for close investigation, normally over 2 hours. The main purpose of our work is to present a novel machine vision approach to reduce diagnosis time by automatically detecting duplicated recordings caused by backward camera movement, typically containing redundant information, in small intestine. The developed technique could be integrated with a visualization tool which supports intelligent inspection method, such as automatic play speed control. Our experimental result shows high accuracy of the technique by detecting 989 duplicate image frames out of 10,000, equivalently to 9.9% data reduction, in a WCE video from a real human subject. With some selected parameters, we achieved the correct detection ratio of 92.85% and the false detection ratio of 13.57%.

  11. Endoscopy in Canada: Proceedings of the National Roundtable

    PubMed Central

    Switzer, Noah; Dixon, Elijah; Tinmouth, Jill; Bradley, Nori; Vassiliou, Melina; Schwaitzberg, Steve; Gomes, Anthony; Ellsmere, James; de Gara, Chris

    2015-01-01

    This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists. PMID:25886520

  12. The endoscopy Global Rating Scale – Canada: Development and implementation of a quality improvement tool

    PubMed Central

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George

    2013-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242

  13. Capsule injection system for a hydraulic capsule pipelining system

    DOEpatents

    Liu, Henry

    1982-01-01

    An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

  14. Tethered capsule endomicroscopy: from bench to bedside at a primary care practice

    NASA Astrophysics Data System (ADS)

    Gora, Michalina J.; Simmons, Leigh H.; Quénéhervé, Lucille; Grant, Catriona N.; Carruth, Robert W.; Lu, Weina; Tiernan, Aubrey; Dong, Jing; Walker-Corkery, Beth; Soomro, Amna; Rosenberg, Mireille; Metlay, Joshua P.; Tearney, Guillermo J.

    2016-10-01

    Due to the relatively high cost and inconvenience of upper endoscopic biopsy and the rising incidence of esophageal adenocarcinoma, there is currently a need for an improved method for screening for Barrett's esophagus. Ideally, such a test would be applied in the primary care setting and patients referred to endoscopy if the result is suspicious for Barrett's. Tethered capsule endomicroscopy (TCE) is a recently developed technology that rapidly acquires microscopic images of the entire esophagus in unsedated subjects. Here, we present our first experience with clinical translation and feasibility of TCE in a primary care practice. The acceptance of the TCE device by the primary care clinical staff and patients shows the potential of this device to be useful as a screening tool for a broader population.

  15. What the Research Tells Us: Class Size Reduction. Information Capsule. Volume 1001

    ERIC Educational Resources Information Center

    Romanik, Dale

    2010-01-01

    This Information Capsule examines the background and history in addition to research findings pertaining to class size reduction (CSR). This Capsule concludes that although educational researchers have not definitively agreed upon the effectiveness of CSR, given its almost universal public appeal, there is little doubt it is here to stay in some…

  16. Operative endoscopy of the airway

    PubMed Central

    Walters, Dustin M.

    2016-01-01

    Airway endoscopy has long been an important and useful tool in the management of thoracic diseases. As thoracic specialists have gained experience with both flexible and rigid bronchoscopic techniques, the technology has continued to evolve so that bronchoscopy is currently the foundation for diagnosis and treatment of many thoracic ailments. Airway endoscopy plays a significant role in the biopsy of tumors within the airways, mediastinum, and lung parenchyma. Endoscopic methods have been developed to treat benign and malignant airway stenoses and tracheomalacia. And more recently, techniques have been conceived to treat end-stage emphysema and prolonged air leaks in select patients. This review describes the abundant uses of airway endoscopy, as well as technical considerations and limitations of the current technologies. PMID:26981263

  17. Remote transmission of live endoscopy over the Internet: Report from the 87th Congress of the Japan Gastroenterological Endoscopy Society.

    PubMed

    Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao

    2016-01-01

    Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  18. System for clinical photometric stereo endoscopy

    NASA Astrophysics Data System (ADS)

    Durr, Nicholas J.; González, Germán.; Lim, Daryl; Traverso, Giovanni; Nishioka, Norman S.; Vakoc, Benjamin J.; Parot, Vicente

    2014-02-01

    Photometric stereo endoscopy is a technique that captures information about the high-spatial-frequency topography of the field of view simultaneously with a conventional color image. Here we describe a system that will enable photometric stereo endoscopy to be clinically evaluated in the large intestine of human patients. The clinical photometric stereo endoscopy system consists of a commercial gastroscope, a commercial video processor, an image capturing and processing unit, custom synchronization electronics, white light LEDs, a set of four fibers with diffusing tips, and an alignment cap. The custom pieces that come into contact with the patient are composed of biocompatible materials that can be sterilized before use. The components can then be assembled in the endoscopy suite before use. The resulting endoscope has the same outer diameter as a conventional colonoscope (14 mm), plugs into a commercial video processor, captures topography and color images at 15 Hz, and displays the conventional color image to the gastroenterologist in real-time. We show that this system can capture a color and topographical video in a tubular colon phantom, demonstrating robustness to complex geometries and motion. The reported system is suitable for in vivo evaluation of photometric stereo endoscopy in the human large intestine.

  19. Efficiency of upper gastrointestinal endoscopy in pediatric surgical practice

    PubMed Central

    Temiz, Abdulkerim

    2015-01-01

    After the introduction of flexible fiber optic endoscopy to pediatric gastroenterology in the 1970s, upper gastrointestinal (UGI) endoscopy can be performed for the diagnosis and treatment of all age groups of children. We review indications, contraindications, preparation of patients for the procedure, and details of diagnostic and therapeutic UGI endoscopy used in pediatric surgery. We also discuss potential complications of endoscopy. PMID:26566483

  20. First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel: a pilot study.

    PubMed

    Friedrich, Kilian; Gehrke, Sven; Stremmel, Wolfgang; Sieg, Andreas

    2013-09-01

    Capsule endoscopy is the first-line diagnostic technique for the small bowel. However, the inability to visualize the duodenal papilla is an inherent limitation of this method. In the present study, we evaluated feasibility of a newly developed CapsoCam SV1 capsule. This is a prospective dual center study of a newly developed video capsule CapsoCam SV1 from Capsovision, CA, providing panoramic 360° imaging. A high frequency of 20 frames occurs per second for the first 2 h and thereafter 12 frames/s, with a battery life of 15 h. We evaluated feasibility and completeness of small bowel examination together with secondary endpoints of duodenal papilla detection in 33 patients. Patients swallowed the capsules following colonoscopy or were prepared with 2 L of polyethylene glycol solution prior to the examination. All patients swallowed 20 mg of metoclopramide and 160 mg of simethicone 30 min before ingestion of the capsule. Thirty-one of the 33 patients' data could be evaluated. Small bowel examination was complete in all procedures. Mean time to pass the small bowel was 258 ± 136 min. Average small bowel cleanliness was 3.3 ± 0.5. In 71% of the patients, we identified the duodenal papilla. No adverse reaction in relation to the capsule examination was observed. CapsoCam SV1 is a safe and efficient tool in small bowel examination. The duodenal papilla as the only landmark in small bowel is detected in more than 70% of the patients. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  1. Virtual reality simulators for gastrointestinal endoscopy training

    PubMed Central

    Triantafyllou, Konstantinos; Lazaridis, Lazaros Dimitrios; Dimitriadis, George D

    2014-01-01

    The use of simulators as educational tools for medical procedures is spreading rapidly and many efforts have been made for their implementation in gastrointestinal endoscopy training. Endoscopy simulation training has been suggested for ascertaining patient safety while positively influencing the trainees’ learning curve. Virtual simulators are the most promising tool among all available types of simulators. These integrated modalities offer a human-like endoscopy experience by combining virtual images of the gastrointestinal tract and haptic realism with using a customized endoscope. From their first steps in the 1980s until today, research involving virtual endoscopic simulators can be divided in two categories: investigation of the impact of virtual simulator training in acquiring endoscopy skills and measuring competence. Emphasis should also be given to the financial impact of their implementation in endoscopy, including the cost of these state-of-the-art simulators and the potential economic benefits from their usage. Advances in technology will contribute to the upgrade of existing models and the development of new ones; while further research should be carried out to discover new fields of application. PMID:24527175

  2. Guidelines for Safety in the Gastrointestinal Endoscopy Unit

    PubMed Central

    Calderwood, Audrey H.; Chapman, Frank J.; Cohen, Jonathan; Cohen, Lawrence B.; Collins, James; Day, Lukejohn W.; Early, Dayna S.

    2014-01-01

    EXECUTIVE SUMMARY Historically, safety in the gastrointestinal (GI) endoscopy unit has focused on infection control, particularly around the reprocessing of endoscopes. Two highly publicized outbreaks where the transmission of infectious agents were related to GI endoscopy have highlighted the need to address potential gaps along the endoscopy care continuum that could impact patient safety. PMID:24485393

  3. Panic Attack during Elective Gastrointestinal Endoscopy.

    PubMed

    Mitsonis, Charalampos; Dimopoulos, Nikolaos; Zavrou, Marianna; Psarra, Vassiliki; Giofkos, Christos; Fiorakis, Christos; Dimitriadis, Athanasios; Valavanis, Dimitrios; Vousoura, Eleni; Zervas, Iannis; Papavassiliou, Efstathios

    2011-01-01

    Background. Esophagogastroduodenoscopy (EGD) and colonoscopy (CS) can evoke anxiety, embarrassment, and discomfort. These concerns can culminate in panic attacks, which may traumatize patients and significantly decrease their compliance to the procedure. The objective of this study was to evaluate the relationship between preendoscopic anxiety and the possibility of a panic attack during an elective gastrointestinal endoscopy (EGE). Methods. The study population comprised of 79 Greek outpatients. The examination was carried out without the use of conscious sedation. Patients' anxiety levels were assessed before the procedure using the Greek version of the Spielberger State-Trait Anxiety Inventory (STAI-Y). Results. Seventy-nine patients were enrolled: 45 EGD and 34 CS. Females had higher state and trait anxiety levels than males (48.14 ± 7.94 versus 44.17 ± 7.43, P < 0.05; and 43.68 ± 6.95 versus 39.86 ± 7.46, P < 0.05). Patients who experienced panic attack had significantly higher levels of both trait and state anxiety, compared to those who were panic-free. There was no significant relationship between panic attacks and sex or type of procedure. Conclusions. Patients who experience panic attacks during endoscopic procedures appear to have significantly higher anxiety levels before the procedure. Administering the STAI questionnaire prior to the endoscopy seems to be a useful screening method for vulnerable patients.

  4. Is a fecal occult blood test a useful tool for judging whether to perform capsule endoscopy in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy?

    PubMed

    Endo, Hiroki; Kato, Takayuki; Sakai, Eiji; Taniguchi, Leo; Arimoto, Jun; Kawamura, Harunobu; Higurashi, Takuma; Ohkubo, Hidenori; Nonaka, Takashi; Taguri, Masataka; Inamori, Masahiko; Yamanaka, Takeharu; Sakaguchi, Takashi; Hata, Yasuo; Nagase, Hajime; Nakajima, Atsushi

    2017-02-01

    Aspirin use is reportedly not to be associated with fecal immunochemical occult blood test (FIT) false-positive results for the detection of colorectal cancer. The need for additional small bowel exploration in FIT-positive, low-dose aspirin users with a negative colonoscopy is controversial. The aim of this study was to assess the ability of FIT to judge whether capsule endoscopy (CE) should be performed in low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy findings by comparing FIT results with CE findings. A total of 264 consecutive low-dose aspirin users with negative colonoscopy and esophagogastroduodenoscopy who were scheduled to undergo CE at five hospitals in Japan were enrolled. Patients had been offered FIT prior to the CE. The association between the FIT results and the CE findings was then assessed. One hundred and fifty-seven patients were included in the final analysis. Eighty-four patients (53.5 %) had positive FIT results. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of positive FIT results for small bowel ulcers were 0.56, 0.47, 0.30, and 0.73, respectively. Furthermore, the NPV of positive FIT results for severe small bowel injury (Lewis score ≥790) was markedly high (0.90). When the analysis was performed only in low-dose aspirin users with anemia, the sensitivity of the positive FIT results was notably improved (0.72). Small bowel evaluation using CE is not recommended for FIT-negative, low-dose aspirin users. However, small bowel evaluation using CE should be considered in both FIT-positive and anemic low-dose aspirin users.

  5. Evidence of the Internationalization of Clinical Endoscopy Based on Journal Metrics

    PubMed Central

    2015-01-01

    Background/Aims This study aims to verify the internationalization of Clinical Endoscopy based on journal metrics after the change to English-only in 2011. The results of this study serve as a starting point for developing strategies to develop Clinical Endoscopy into a top-tier international journal. Methods The following journal metrics were analyzed from the journal's homepage or the Web of Science: the number of citable articles, number of countries of affiliation of the contributors, the number of articles supported by research grants, total citations, impact factor, citing journals, countries of citing authors, and the Hirsch index. Results The number of citable articles in 2011, 2012, 2013, and 2014 was 22, 81, 120, and 95, respectively. The authors were from 11 countries. Twenty-one out of 55 original articles were supported by research grants. The total citations in 2012, 2013, and 2014 were 2, 85, and 213, respectively. The impact factor was 0.670 in 2013 and 0.940 in 2014. The number of countries citing authors were from was 61. The Hirsch index was 6. Conclusions The above results demonstrate that Clinical Endoscopy became an international journal, contributing to the propagation of valuable research results through an open access publishing model. PMID:26240806

  6. Philipp Bozzini (1773-1809): The earliest description of endoscopy.

    PubMed

    Ramai, Daryl; Zakhia, Karl; Etienne, Denzil; Reddy, Madhavi

    2018-05-01

    The widespread use of endoscopy in today's clinical arena underscores its utility and growing significance within the field of medicine. Primitive forms of endoscopy have existed for hundreds of years, but it was not until the early 19th century that Dr Philipp Bozzini invented an endoscope that would form the basis of modern endoscopy. Born into an influential Italian family, Bozzini practiced medicine in a time and place of conflict and political unrest. His passion, ingenuity, and important social connections allowed him to create and introduce to the medical profession the Lichtleiter (light-conductor), which overcame two key issues plaguing endoscopy: inadequate lighting and poor penetration. A combination of professional rivalry and his premature passing stifled enthusiasm and further work on the Lichtleiter, but its value would not be lost forever. The advancements in the field of endoscopy that have come since the time of the Lichtleiter all build upon the principles of Bozzini, who became widely acknowledged as the father of modern endoscopy.

  7. Aldehyde disinfectants and health in endoscopy units. British Society of Gastroenterology Endoscopy Committee.

    PubMed

    Cowan, R E; Manning, A P; Ayliffe, G A; Axon, A T; Causton, J S; Cripps, N F; Hall, R; Hanson, P J; Harrison, J; Leicester, R J

    1993-11-01

    Summary of main recommendations(1) Glutaraldehyde, used in most endoscopy units in the United Kingdom for the disinfection of flexible gastrointestinal endoscopes, is a toxic substance being an irritant and a sensitiser; symptoms associated with glutaraldehyde exposure are common among staff working in endoscopy units.(2) The Control of Substances Hazardous to Health Regulations 1988 (COSHH) obliges the employer to make a systematic assessment of risk to staff of exposure to glutaraldehyde and institute measures to deal effectively with exposure.(3) At present glutaraldehyde remains the first line agent for the disinfection of flexible gastrointestinal endoscopes. Other agents are being developed; a standard means of assessment for flexible endoscope disinfectants should be devised.(4) Equipment and accessories that are heat stable should be sterilised by autoclaving; disposable accessories should be used wherever possible.(5) Flexible gastrointestinal endoscopes should be disinfected within automated washer/disinfectors; trays, bowls or buckets for this purpose are unacceptable.(6) Local exhaust ventilation must be used to control glutaraldehyde vapour. Extracted air may be discharged direct to the atmosphere or passed over special absorbent filters and recirculated. Such control measures must be regularly tested and records retained.(7) Endoscope cleaning and disinfection should be carried out in a room dedicated to the purpose, equipped with control measures to maintain the concentration of glutaraldehyde vapour at a level certainly below the current occupational exposure standard of 0.2 ppm and preferably below the commonly used working limit of 0.1 ppm. Sites other than the endoscopy unit where endoscopy is regularly performed, such as the radiology department, should have their own fully equipped cleaning and disinfection room.(8) COSHH limits the use of personal protective equipment to those situations where other measures cannot adequately control exposure

  8. Development of Bariatric and Metabolic Endoscopy

    PubMed Central

    Li, Shi-Han; Wang, Yong-Jun; Zhang, Shu-Tian

    2018-01-01

    Objective: With the evolution of society and changes in human lifestyle, obesity is becoming increasingly prevalent worldwide, and obesity-related comorbidities such as diabetes, hyperlipidemia, hypertension, and coronary heart disease are more common. As a result, new devices and methods for bariatric and metabolic endoscopy are being developed for clinical use, offering new options for patients. This review discussed the progress in bariatric and metabolic endoscopy. Data Sources: This review was based on data in articles published in the PubMed database up to September 2017, with the following keywords: “obesity”, “endoscopy”, “weight loss”, and “metabolism”. Study Selection: Original articles about various endoscopic methods of weight loss and other reviews of bariatric and metabolic endoscopy were included and analyzed. Results: The technology of bariatric and metabolic endoscopy has advanced rapidly in recent years. The intragastric balloon (IGB), with its comparatively long period of development, is the most mature and widely used instrument. Multiple new endoscopic devices have been created in recent years, with different targets to achieve weight loss. Despite the proliferation of new devices, the lack of clinical data results in a shortage of clinical experience and instruction in the use of this new equipment. Conclusions: Bariatric and metabolic endoscopy would help obese people lose weight or prepare for bariatric surgery and hopefully alleviate some of the complications of bariatric procedures. Adequate studies and data are still needed for the new endoscopic devices. PMID:29271386

  9. Posterior capsule opacification.

    PubMed

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  10. Flexible Gastrointestinal Endoscopy in Ferrets (Mustela putorius furo).

    PubMed

    Pignon, Charly; Huynh, Minh; Husnik, Roman; Jekl, Vladimir

    2015-09-01

    Gastrointestinal disease is a common complaint in ferrets (Mustela putorius furo). Their relatively simple and short gastrointestinal tract makes them good candidates for flexible endoscopy. However, apart from a few references in biomedical research articles, there is little information on the use of flexible endoscopy in ferrets. This review describes patient preparation, equipment, and select gastrointestinal endoscopy techniques in ferrets, including esophagoscopy, gastroscopy, duodenoscopy, percutaneous endoscopic gastrostomy, jejunoileoscopy, colonoscopy, and biopsy. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Indicators of safety compromise in gastrointestinal endoscopy.

    PubMed

    Borgaonkar, Mark Ram; Hookey, Lawrence; Hollingworth, Roger; Kuipers, Ernst J; Forster, Alan; Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Macintosh, Donald; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Valori, Roland

    2012-02-01

    The importance of quality indicators has become increasingly recognized in gastrointestinal endoscopy. Patient safety requires the identification and monitoring of occurrences associated with harm or the potential for harm. The identification of relevant indicators of safety compromise is, therefore, a critical element that is key to the effective implementation of endoscopy quality improvement programs. To identify key indicators of safety compromise in gastrointestinal endoscopy. The Canadian Association of Gastroenterology Safety and Quality Indicators in Endoscopy Consensus Group was formed to address issues of quality in endoscopy. A subcommittee was formed to identify key safety indicators. A systematic literature review was undertaken, and articles pertinent to safety in endoscopy were identified and reviewed. All complications and measures used to document safety were recorded. From this, a preliminary list of 16 indicators was compiled and presented to the 35-person consensus group during a three-day meeting. A revised list of 20 items was subsequently put to the consensus group for vote for inclusion on the final list of safety indicators. Items were retained only if the consensus group highly agreed on their importance. A total of 19 indicators of safety compromise were retained and grouped into the three following categories: medication-related - the need for CPR, use of reversal agents, hypoxia, hypotension, hypertension, sedation doses in patients older than 70 years of age, allergic reactions and laryngospasm⁄bronchospasm; procedure-related early - perforation, immediate postpolypectomy bleeding, need for hospital admission or transfer to emergency department from the gastroenterology unit, instrument impaction, severe persistent abdominal pain requiring evaluation proven to not be perforation; and procedure-related delayed - death within 30 days of procedure, 14-day unplanned hospitalization, 14-day unplanned contact with a health provider

  12. Real-time fluorescence target/background (T/B) ratio calculation in multimodal endoscopy for detecting GI tract cancer

    NASA Astrophysics Data System (ADS)

    Jiang, Yang; Gong, Yuanzheng; Wang, Thomas D.; Seibel, Eric J.

    2017-02-01

    Multimodal endoscopy, with fluorescence-labeled probes binding to overexpressed molecular targets, is a promising technology to visualize early-stage cancer. T/B ratio is the quantitative analysis used to correlate fluorescence regions to cancer. Currently, T/B ratio calculation is post-processing and does not provide real-time feedback to the endoscopist. To achieve real-time computer assisted diagnosis (CAD), we establish image processing protocols for calculating T/B ratio and locating high-risk fluorescence regions for guiding biopsy and therapy in Barrett's esophagus (BE) patients. Methods: Chan-Vese algorithm, an active contour model, is used to segment high-risk regions in fluorescence videos. A semi-implicit gradient descent method was applied to minimize the energy function of this algorithm and evolve the segmentation. The surrounding background was then identified using morphology operation. The average T/B ratio was computed and regions of interest were highlighted based on user-selected thresholding. Evaluation was conducted on 50 fluorescence videos acquired from clinical video recordings using a custom multimodal endoscope. Results: With a processing speed of 2 fps on a laptop computer, we obtained accurate segmentation of high-risk regions examined by experts. For each case, the clinical user could optimize target boundary by changing the penalty on area inside the contour. Conclusion: Automatic and real-time procedure of calculating T/B ratio and identifying high-risk regions of early esophageal cancer was developed. Future work will increase processing speed to <5 fps, refine the clinical interface, and apply to additional GI cancers and fluorescence peptides.

  13. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.

    PubMed

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-08-01

    At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.

  14. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo

    PubMed Central

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2013-01-01

    Presently, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures which provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high resolution images, it is also safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically-specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically-relevant depths, ideal for soft tissue imaging. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, enabling multi-modality imaging with complementary contrast. Here, we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and demonstrate its ability to image internal organs in vivo, illustrating its potential clinical application. PMID:22797808

  15. Endoscopy in neutropenic and/or thrombocytopenic patients

    PubMed Central

    Tong, Michelle C; Tadros, Micheal; Vaziri, Haleh

    2015-01-01

    AIM: To evaluate the safety of endoscopic procedures in neutropenic and/or thrombocytopenic cancer patients. METHODS: We performed a literature search for English language studies in which patients with neutropenia and/or thrombocytopenia underwent endoscopy. Studies were included if endoscopic procedures were used as part of the evaluation of neutropenic and/or thrombocytopenic patients, yielding 13 studies. Two studies in which endoscopy was not a primary evaluation tool were excluded. Eleven relevant studies were identified by two independent reviewers on PubMed, Scopus, and Ovid databases. RESULTS: Most of the studies had high diagnostic yield with relatively low complication rates. Therapeutic endoscopic interventions were performed in more than half the studies, including high-risk procedures, such as sclerotherapy. Platelet transfusion was given if counts were less than 50000/mm3 in four studies and less than 10000/mm3 in one study. Other thrombocytopenic precautions included withholding of biopsy if platelet count was less than 30000/mm3 in one study and less than 20000/mm3 in another study. Two of the ten studies which examined thrombocytopenic patient populations reported bleeding complications related to endoscopy, none of which caused major morbidity or mortality. All febrile neutropenic patients received prophylactic broad-spectrum antibiotics in the studies reviewed. Regarding afebrile neutropenic patients, prophylactic antibiotics were given if absolute neutrophil count was less than 1000/mm3 in one study, if the patient was undergoing colonoscopy and had a high inflammatory condition without clear definition of significance in another study, and if the patient was in an aplastic phase in a third study. Endoscopy was also withheld in one study for severe pancytopenia. CONCLUSION: Endoscopy can be safely performed in patients with thrombocytopenia/neutropenia. Prophylactic platelet transfusion and/or antibiotic administration prior to endoscopy may be

  16. Feasibility of real‐time near‐infrared indocyanine green fluorescence endoscopy for the evaluation of mucosal head and neck lesions

    PubMed Central

    Schmidt, Florian; Dittberner, Andreas; Koscielny, Sven; Petersen, Iver

    2016-01-01

    Abstract Background The purpose of this study was to explore the feasibility and potential drawbacks of near‐infrared (NIR) endoscopy with indocyanine green (ICG) to examine mucosal head and neck lesions. Methods NIR ICG endoscopy was applied to image head and neck cancer epithelium in vivo. The evaluation of the ICG videos was performed off‐line independently by 2 evaluators and blinded with respect to final histopathological results from biopsies taken as the gold standard. Results Forty percent of the lesions from 55 patients were histologically malignant. ICG positivity showed a sensitivity, specificity, and accuracy to be related to a malignant tumor of 90.5%, 90.9%, and 89.1%, respectively. The kappa index for the interobserver assessment showed a 94.4% agreement for the assessment of the ICG positivity. Side effects of the NIR ICG endoscopy did not arise. Conclusion NIR ICG endoscopy in patients with mucosal head and neck lesions was feasible and safe. It might help intraoperatively to differentiate benign from malignant lesions. © 2016 Wiley Periodicals, Inc. Head Neck 39: 234–240, 2017 PMID:27590351

  17. Pediatric gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) and European Society for Paediatric Gastroenterology Hepatology and Nutrition (ESPGHAN) Guideline Executive summary.

    PubMed

    Tringali, Andrea; Thomson, Mike; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf Dietrich; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro

    2017-01-01

    This Executive summary of the Guideline on pediatric gastrointestinal endoscopy from the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society for Paediatric Gastroenterology Hepatology and Nutrition (ESPGHAN) refers to infants, children, and adolescents aged 0 - 18 years. The areas covered include: indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; endoscopic management of corrosive ingestion and stricture/stenosis; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography, and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease (IBD) have been dealt with in other Guidelines and are therefore not mentioned in this Guideline. Training and ongoing skill maintenance will be addressed in an imminent sister publication. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Biocompatible Capsules and Methods of Making

    NASA Technical Reports Server (NTRS)

    Loftus, David J. (Inventor)

    2017-01-01

    Embodiments of the invention include capsules for containing medical implants and delivery systems for release of active biological substances into a host body. Delivery systems comprise a capsule comprising an interior enclosed by walls, and a source of active biological substances enclosed within the capsule interior, wherein the active biological substances are free to diffuse across the capsule walls. The capsule walls comprise a continuous mesh of biocompatible fibers and a seal region where two capsule walls overlap. The interior of the capsule is substantially isolated from the medium surrounding the capsule, except for diffusion of at least one species of molecule between the capsule interior and the ambient medium, and prevents cell migration into or out of the capsule. Methods for preparing and using the capsules and delivery systems are provided.

  19. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    PubMed

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  20. Efficiency of endoscopy units can be improved with use of discrete event simulation modeling.

    PubMed

    Sauer, Bryan G; Singh, Kanwar P; Wagner, Barry L; Vanden Hoek, Matthew S; Twilley, Katherine; Cohn, Steven M; Shami, Vanessa M; Wang, Andrew Y

    2016-11-01

    Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience.

  1. Photometric stereo endoscopy.

    PubMed

    Parot, Vicente; Lim, Daryl; González, Germán; Traverso, Giovanni; Nishioka, Norman S; Vakoc, Benjamin J; Durr, Nicholas J

    2013-07-01

    While color video endoscopy has enabled wide-field examination of the gastrointestinal tract, it often misses or incorrectly classifies lesions. Many of these missed lesions exhibit characteristic three-dimensional surface topographies. An endoscopic system that adds topographical measurements to conventional color imagery could therefore increase lesion detection and improve classification accuracy. We introduce photometric stereo endoscopy (PSE), a technique which allows high spatial frequency components of surface topography to be acquired simultaneously with conventional two-dimensional color imagery. We implement this technique in an endoscopic form factor and demonstrate that it can acquire the topography of small features with complex geometries and heterogeneous optical properties. PSE imaging of ex vivo human gastrointestinal tissue shows that surface topography measurements enable differentiation of abnormal shapes from surrounding normal tissue. Together, these results confirm that the topographical measurements can be obtained with relatively simple hardware in an endoscopic form factor, and suggest the potential of PSE to improve lesion detection and classification in gastrointestinal imaging.

  2. Photometric stereo endoscopy

    PubMed Central

    Parot, Vicente; Lim, Daryl; González, Germán; Traverso, Giovanni; Nishioka, Norman S.; Vakoc, Benjamin J.

    2013-01-01

    Abstract. While color video endoscopy has enabled wide-field examination of the gastrointestinal tract, it often misses or incorrectly classifies lesions. Many of these missed lesions exhibit characteristic three-dimensional surface topographies. An endoscopic system that adds topographical measurements to conventional color imagery could therefore increase lesion detection and improve classification accuracy. We introduce photometric stereo endoscopy (PSE), a technique which allows high spatial frequency components of surface topography to be acquired simultaneously with conventional two-dimensional color imagery. We implement this technique in an endoscopic form factor and demonstrate that it can acquire the topography of small features with complex geometries and heterogeneous optical properties. PSE imaging of ex vivo human gastrointestinal tissue shows that surface topography measurements enable differentiation of abnormal shapes from surrounding normal tissue. Together, these results confirm that the topographical measurements can be obtained with relatively simple hardware in an endoscopic form factor, and suggest the potential of PSE to improve lesion detection and classification in gastrointestinal imaging. PMID:23864015

  3. Swallowing Tablets and Capsules Increases the Risk of Penetration and Aspiration in Patients with Stroke-Induced Dysphagia.

    PubMed

    Schiele, Julia T; Penner, Heike; Schneider, Hendrik; Quinzler, Renate; Reich, Gabriele; Wezler, Nikolai; Micol, William; Oster, Peter; Haefeli, Walter E

    2015-10-01

    We evaluated the prevalence of difficulties swallowing solid dosage forms in patients with stroke-induced dysphagia and whether swallowing tablets/capsules increases their risk of penetration and aspiration. Concurrently, we explored whether routinely performed assessment tests help identify patients at risk. Using video endoscopy, we evaluated how 52 patients swallowed four different placebos (round, oval, and oblong tablets and a capsule) with texture-modified water (TMW, pudding consistency) and milk and rated their swallowing performance according to the Penetration Aspiration Scale (PAS). Additionally, Daniels Test, Bogenhausener Dysphagiescore, Scandinavian Stroke Scale, Barthel Index, and Tinetti's Mobility Test were conducted. A substantial proportion of the patients experienced severe difficulties swallowing solid oral dosage forms (TMW: 40.4 %, milk: 43.5 %). Compared to the administration of TMW/milk alone, the placebos increased the PAS values in the majority of the patients (TMW: median PAS from 1.5 to 2.0; milk: median PAS from 1.5 to 2.5, each p value <0.0001) and residue values were significantly higher (p < 0.05). Whereas video-endoscopic examination reliably identified patients with difficulties swallowing medication, neither patients' self-evaluation nor one of the routinely performed bedside tests did. Therefore, before video-endoscopic evaluation, many drugs were modified unnecessarily and 20.8 % of these were crushed inadequately, although switching to another dosage form or drug would have been possible. Hence, safety and effectiveness of swallowing tablets and capsules should be evaluated routinely in video-endoscopic examinations, tablets/capsules should rather be provided with TMW than with milk, and the appropriateness of "non per os except medication" orders for dysphagic stroke patients should be questioned.

  4. Optimizing the villi visualization by tethered capsule OCT endomicroscopy for comprehensive imaging of human duodenum (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dong, Jing; Gora, Michalina J.; Beaulieu-Ouellet, Emilie; Queneherve, Lucille H.; Grant, Catriona N.; Rosenberg, Mireille; Nishioka, Norman S.; Fasano, Alessio; Tearney, Guillermo J.

    2017-02-01

    Celiac disease (CD) affects around 1% of the global population and can cause serious long-term symptoms including malnutrition, fatigue, and diarrhea, amongst others. Despite this, it is often left undiagnosed. Currently, a tissue diagnosis of CD is made by random endoscopic biopsy of the duodenum to confirm the existence of microscopic morphologic alterations in the intestinal mucosa. However, duodenal endoscopic biopsy is problematic because the morphological changes can be focal and endoscopic biopsy is plagued by sampling error. Additionally, tissue artifacts can also an issue because cuts in the transverse plane can make duodenal villi appear artifactually shortened and can bias the assessment of intraepithelial inflammation. Moreover, endoscopic biopsy is costly and poorly tolerated as the patient needs to be sedated to perform the procedure. Our lab has previously developed technology termed tethered capsule OCT endomicroscopy (TCE) to overcome these diagnostic limitations of endoscopy. TCE involves swallowing an optomechanically-engineered pill that generates 3D images of the GI tract as it traverses the lumen of the organ via peristalsis, assisted by gravity. In several patients we have demonstrated TCE imaging of duodenal villi, however the current TCE device design is not optimal for CD diagnosis as the villi compress when in contact with the smooth capsule's wall. In this work, we present methods for structuring the outer surface of the capsule to improve the visualization of the villi height and crypt depth. Preliminary results in humans suggest that new TCE capsule enables better visualization of villous architecture, making it possibly to comprehensively scan the entire duodenum to obtain a more accurate tissue diagnosis of CD.

  5. Alternative Agents to Prevent Fogging in Head and Neck Endoscopy

    PubMed Central

    Piromchai, Patorn; Kasemsiri, Pornthep; Thanaviratananich, Sanguansak

    2011-01-01

    Background: The essential factor for diagnosis and treatment of diseases in head and neck endoscopy is the visibility of the image. An anti-fogging agent can reduce this problem by minimizing surface tension to prevent the condensation of water in the form of small droplets on a surface. There is no report on the use of hibiscrub® or baby shampoo to reduce fogging in the literature. The objective of this study was to compare the efficacy between commercial anti-fogging agent, hibiscrub® and baby shampoo to reduce fogging for the use in head and neck endoscopy. Methods: The study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University in August 2010. Commercial anti-fogging agent, baby shampoo and hibiscrub® were applied on rigid endoscope lens before putting them into a mist generator. The images were taken at baseline, 15 seconds, 30 seconds and 1 minute. The images’ identifiers were removed before they were sent to two evaluators. A visual analogue scale (VAS) was used to rate the image quality from 0 to 10. Results: The difference in mean VAS score between anti-fogging agent, baby shampoo and hibiscrub® versus no agent were 5.46, 4.45 and 2.1 respectively. The commercial anti-fogging agent and baby shampoo had most protective benefit and performed significantly better than no agent (P = 0.05). Conclusions: Baby shampoo is an effective agent to prevent fogging during head and neck endoscopy and compares favourably with commercial anti-fogging agent. PMID:24179399

  6. Remote magnetic control of a wireless capsule endoscope in the esophagus is safe and feasible: results of a randomized, clinical trial in healthy volunteers.

    PubMed

    Keller, Jutta; Fibbe, Christiane; Volke, Frank; Gerber, Jeremy; Mosse, Alexander C; Reimann-Zawadzki, Meike; Rabinovitz, Elisha; Layer, Peter; Swain, Paul

    2010-11-01

    Remote control of esophageal capsule endoscopes could enhance diagnostic accuracy. To assess the safety and efficacy of remote magnetic manipulation of a modified capsule endoscope (magnetic maneuverable capsule [MMC]; Given Imaging Ltd, Yoqneam, Israel) in the esophagus of healthy humans. Randomized, controlled trial. Academic hospital. This study involved 10 healthy volunteers. All participants swallowed a conventional capsule (ESO2; Given Imaging) and a capsule endoscope with magnetic material, the MMC, which is activated by a thermal switch, in random order (1 week apart). An external magnetic paddle (EMP; Given Imaging) was used to manipulate the MMC within the esophageal lumen. MMC responsiveness was evaluated on a screen showing the MMC film in real time. Safety and tolerability of the procedure (questionnaire), responsiveness of the MMC to the EMP, esophageal transit time, and visualization of the Z-line. No adverse events occurred apart from mild retrosternal pressure (n = 5). The ability to rotate the MMC around its longitudinal axis and to tilt it by defined movements of the EMP was clearly demonstrated in 9 volunteers. Esophageal transit time was highly variable for both capsules (MMC, 111-1514 seconds; ESO2, 47-1474 seconds), but the MMC stayed longer in the esophagus in 8 participants (P < .01). Visualization of the Z-line was more efficient with the ESO2 (inspection of 73% ± 18% of the circumference vs 33% ± 27%, P = .01). Magnetic forces were not strong enough to hold the MMC against peristalsis when the capsule approached the gastroesophageal junction. Remote control of the MMC in the esophagus of healthy volunteers is safe and feasible, but higher magnetic forces may be needed. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  7. Virtual endoscopy in neurosurgery: a review.

    PubMed

    Neubauer, André; Wolfsberger, Stefan

    2013-01-01

    Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.

  8. Development and validation of a scoring index to predict the presence of lesions in capsule endoscopy in patients with suspected Crohn's disease of the small bowel: a Spanish multicenter study.

    PubMed

    Egea-Valenzuela, Juan; González Suárez, Begoña; Sierra Bernal, Cristian; Juanmartiñena Fernández, José Francisco; Luján-Sanchís, Marisol; San Juan Acosta, Mileidis; Martínez Andrés, Blanca; Pons Beltrán, Vicente; Sastre Lozano, Violeta; Carretero Ribón, Cristina; de Vera Almenar, Félix; Sánchez Cuenca, Joaquín; Alberca de Las Parras, Fernando; Rodríguez de Miguel, Cristina; Valle Muñoz, Julio; Férnandez-Urién Sainz, Ignacio; Torres González, Carolina; Borque Barrera, Pilar; Pérez-Cuadrado Robles, Enrique; Alonso Lázaro, Noelia; Martínez García, Pilar; Prieto de Frías, César; Carballo Álvarez, Fernando

    2018-05-01

    Capsule endoscopy (CE) is the first-line investigation in cases of suspected Crohn's disease (CD) of the small bowel, but the factors associated with a higher diagnostic yield remain unclear. Our aim is to develop and validate a scoring index to assess the risk of the patients in this setting on the basis of biomarkers. Data on fecal calprotectin, C-reactive protein, and other biomarkers from a population of 124 patients with suspected CD of the small bowel studied by CE and included in a PhD study were used to build a scoring index. This was first used on this population (internal validation process) and after that on a different set of patients from a multicenter study (external validation process). An index was designed in which every biomarker is assigned a score. Three risk groups have been established (low, intermediate, and high). In the internal validation analysis (124 individuals), patients had a 10, 46.5, and 81% probability of showing inflammatory lesions in CE in the low-risk, intermediate-risk, and high-risk groups, respectively. In the external validation analysis, including 410 patients from 12 Spanish hospitals, this probability was 15.8, 49.7, and 80.6% for the low-risk, intermediate-risk, and high-risk groups, respectively. Results from the internal validation process show that the scoring index is coherent, and results from the external validation process confirm its reliability. This index can be a useful tool for selecting patients before CE studies in cases of suspected CD of the small bowel.

  9. Changes in biomechanical properties of glenohumeral joint capsules with adhesive capsulitis by repeated capsule-preserving hydraulic distensions with saline solution and corticosteroid.

    PubMed

    Koh, Eun S; Chung, Sun G; Kim, Tae Uk; Kim, Hee Chan

    2012-12-01

    To investigate whether capsule-preserving hydraulic distension with saline solution and corticosteroid for adhesive capsulitis induces biomechanical alterations in glenohumeral joint capsules along with clinical improvements. A case series. University outpatient clinic of physical medicine and rehabilitation. Eighteen patients with unilateral adhesive capsulitis. INTERVENTION AND MAIN OUTCOME MEASUREMENTS: Three hydraulic distensions with saline solution and corticosteroid were performed with 1-month intervals. To avoid rupturing capsules, all distensions were monitored by using real-time pressure-volume curves. Stiffness, maximal volume capacity, and pressure at the maximal volume capacity of the capsule were measured at each intervention. Clinical parameters, such as pain and range of motion, were recorded before, 3 days after, and 1 month after each distension. Stiffness decreased (47.6 ± 27.1 mm Hg/mL to 31.7 ± 18.4 mm Hg/mL to 24.2 ± 14.0 mm Hg/mL, mean SD) and maximal volume capacity increased (18.8 ± 7.3 mL to 20.5 ± 7.5 mL to 24.2 ± 7.0 mL, mean SD) significantly (P = .001 for both) at each repeated hydraulic distension. Pressure at the maximal volume capacity tended to decrease, but the decrements were not statistically significant (P = .662). The clinical parameters were significantly improved throughout and 1 month after the 3 repeat procedures (P < .05 for all). Capsule-preserving hydraulic distension changed the biomechanical properties of the glenohumeral joint capsule, lessening the stiffness and enlarging the volume capacity. These alterations were accompanied by improved range of motion and relief of pain. Repeated capsule-preserving hydraulic distension with saline solution and corticosteroid would be useful to treat adhesive capsulitis and to evaluate the treatment results. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  10. Bayesian-based localization of wireless capsule endoscope using received signal strength.

    PubMed

    Nadimi, Esmaeil S; Blanes-Vidal, Victoria; Tarokh, Vahid; Johansen, Per Michael

    2014-01-01

    In wireless body area sensor networking (WBASN) applications such as gastrointestinal (GI) tract monitoring using wireless video capsule endoscopy (WCE), the performance of out-of-body wireless link propagating through different body media (i.e. blood, fat, muscle and bone) is still under investigation. Most of the localization algorithms are vulnerable to the variations of path-loss coefficient resulting in unreliable location estimation. In this paper, we propose a novel robust probabilistic Bayesian-based approach using received-signal-strength (RSS) measurements that accounts for Rayleigh fading, variable path-loss exponent and uncertainty in location information received from the neighboring nodes and anchors. The results of this study showed that the localization root mean square error of our Bayesian-based method was 1.6 mm which was very close to the optimum Cramer-Rao lower bound (CRLB) and significantly smaller than that of other existing localization approaches (i.e. classical MDS (64.2mm), dwMDS (32.2mm), MLE (36.3mm) and POCS (2.3mm)).

  11. New techniques for fluorescence background rejection in microscopy and endoscopy

    NASA Astrophysics Data System (ADS)

    Ventalon, Cathie

    2009-03-01

    Confocal microscopy is a popular technique in the bioimaging community, mainly because it provides optical sectioning. However, its standard implementation requires 3-dimensional scanning of focused illumination throughout the sample. Efficient non-scanning alternatives have been implemented, among which the simple and well-established incoherent structured illumination microscopy (SIM) [1]. We recently proposed a similar technique, called Dynamic Speckle Illumination (DSI) microscopy, wherein the incoherent grid illumination pattern is replaced with a coherent speckle illumination pattern from a laser, taking advantage of the fact that speckle contrast is highly maintained in a scattering media, making the technique well adapted to tissue imaging [2]. DSI microscopy relies on the illumination of a sample with a sequence of dynamic speckle patterns and an image processing algorithm based only on an a priori knowledge of speckle statistics. The choice of this post-processing algorithm is crucial to obtain a good sectioning strength: in particular, we developed a novel post-processing algorithm based one wavelet pre-filtering of the raw images and obtained near-confocal fluorescence sectioning in a mouse brain labeled with GFP, with a good image quality maintained throughout a depth of ˜100 μm [3]. In the purpose of imaging fluorescent tissue at higher depth, we recently applied structured illumination to endoscopy. We used a similar set-up wherein the illumination pattern (a one-dimensional grid) is transported to the sample with an imaging fiber bundle with miniaturized objective and the fluorescence image is collected through the same bundle. Using a post-processing algorithm similar to the one previously described [3], we obtained high-quality images of a fluorescein-labeled rat colonic mucosa [4], establishing the potential of our endomicroscope for bioimaging applications. [4pt] Ref: [0pt] [1] M. A. A. Neil et al, Opt. Lett. 22, 1905 (1997) [0pt] [2] C

  12. Mercury Capsule Separation Tests

    NASA Image and Video Library

    1960-04-01

    Mercury capsule separation from Redstone booster in the Altitude Wind Tunnel (AWT): NASA Lewis conducted full-scale separation tests of the posigrade rockets that were fired after the Redstone rockets burned out. The researchers studied the effect of the posigrade rockets firing on the Redstone booster and retrograde package. This film shows the Mercury capsule being mounted to the Redstone missile model in the Altitude Wind Tunnel. The capsule's engines are fired and it horizontally separates from the Atlas. After firing the capsule swings from an overhead crane.

  13. Possibilities and limitations of current stereo-endoscopy.

    PubMed

    Mueller-Richter, U D A; Limberger, A; Weber, P; Ruprecht, K W; Spitzer, W; Schilling, M

    2004-06-01

    Stereo-endoscopy has become a commonly used technology. In many comparative studies striking advantages of stereo-endoscopy over two-dimensional presentation could not be proven. To show the potential and fields for further improvement of this technology is the aim of this article. The physiological basis of three-dimensional vision limitations of current stereo-endoscopes is discussed and fields for further research are indicated. New developments in spatial picture acquisition and spatial picture presentation are discussed. Current limitations of stereo-endoscopy that prevent a better ranking in comparative studies with two-dimensional presentation are mainly based on insufficient picture acquisition. Devices for three-dimensional picture presentation are at a more advanced developmental stage than devices for three-dimensional picture acquisition. Further research should emphasize the development of new devices for three-dimensional picture acquisition.

  14. Portable disposable ultrathin endoscopy tested through percutaneous endoscopic gastrostomy

    PubMed Central

    Baeg, Myong Ki; Lim, Chul-Hyun; Kim, Jin Su; Cho, Yu Kyung; Park, Jae Myung; Lee, Bo-In; Lee, In-Seok; Choi, Myung-Gyu

    2016-01-01

    Abstract Background: A portable disposable ultrathin endoscope (DUE) with high visual quality and maneuverability would reduce the need for expensive facilities and emergency endoscopy could be available anywhere. It would increase patient satisfaction, prevent unnecessary sedation, and reduce infection. Our aim was to evaluate the usefulness of portable DUE in performing percutaneous endoscopic gastrostomy (PEG). Methods: We prospectively enrolled patients who underwent PEG under DUE guidance and compared them with historical controls who underwent PEG under conventional ultrathin endoscopy (CUE) guidance. The primary outcomes were successful stomach visualization and PEG tube insertion. Results: Twenty-five patients (19 male) were enrolled and compared with 25 gender and indication-matched controls. The most common indications for PEG were aspiration due to stroke or brain injury, dementia, and head and neck cancer. Entrance into the stomach was achieved in 92.0% (23/25) and 96% (24/25) in the DUE and CUE groups, and PEG was performed in 91.3% (21/23) and 95.8% (23/24), respectively. The mean insertion time for the DUE and CUE groups were 22.7 ± 9.3 minutes and 17.1 ± 5.7 minutes (P = 0.044). The 3 cases of failure to reach the stomach in both groups were caused by esophageal blockage. The 3 cases of failed PEG tube insertion were caused by poor visualization of the insertion site. Bleeding and pneumoperitoneum occurred in 1 and 2 patients in the DUE group. One case of fever was noted in the CUE group. All adverse events were conservatively managed. Conclusions: Our study shows that portable DUE in facilities without endoscopy equipment may be clinically feasible. PMID:27902596

  15. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  16. Endoscopy in screening for digestive cancer

    PubMed Central

    Lambert, René

    2012-01-01

    The aim of this study is to describe the role of endoscopy in detection and treatment of neoplastic lesions of the digestive mucosa in asymptomatic persons. Esophageal squamous cell cancer occurs in relation to nutritional deficiency and alcohol or tobacco consumption. Esophageal adenocarcinoma develops in Barrett’s esophagus, and stomach cancer in chronic gastric atrophy with Helicobacter pylori infection. Colorectal cancer is favoured by a high intake in calories, excess weight, low physical activity. In opportunistic or individual screening endoscopy is the primary detection procedure offered to an asymptomatic individual. In organized or mass screening proposed by National Health Authorities to a population, endoscopy is performed only in persons found positive to a filter selection test. The indications of primary upper gastrointestinal endoscopy and colonoscopy in opportunistic screening are increasingly developing over the world. Organized screening trials are proposed in some regions of China at high risk for esophageal cancer; the selection test is cytology of a balloon or sponge scrapping; they are proposed in Japan for stomach cancer with photofluorography as a selection test; and in Europe, America and Japan; for colorectal cancer with the fecal occult blood test as a selection test. Organized screening trials in a country require an evaluation: the benefit of the intervention assessed by its impact on incidence and on the 5 year survival for the concerned tumor site; in addition a number of bias interfering with the evaluation have to be controlled. Drawbacks of screening are in the morbidity of the diagnostic and treatment procedures and in overdetection of none clinically relevant lesions. The strategy of endoscopic screening applies to early cancer and to benign adenomatous precursors of adenocarcinoma. Diagnostic endoscopy is conducted in 2 steps: at first detection of an abnormal area through changes in relief, in color or in the course of

  17. Engineering fluorescent poly(dopamine) capsules.

    PubMed

    Chen, Xi; Yan, Yan; Müllner, Markus; van Koeverden, Martin P; Noi, Ka Fung; Zhu, Wei; Caruso, Frank

    2014-03-18

    The recent development of poly(dopamine) (PDA) capsules provides new opportunities for their application in biology and medicine. To advance the biomedical application of PDA capsules, strategies that enable the preparation of fluorescently labeled PDA (F-PDA) capsules are required, as this will allow evaluation of their cellular interactions using a range of fluorescence-based techniques. Herein, we report a facile approach for the fabrication of F-PDA capsules via the polymerization of dopamine (DA) on sacrificial templates in the presence of hydrogen peroxide (H2O2). F-PDA capsules with well-defined sizes are prepared by templating different organic and inorganic particles. The resulting F-PDA capsules show negligible cytotoxicity in HeLa cells after incubation for 48 h. We also demonstrate visualization of the F-PDA capsules following internalization by HeLa cells using conventional fluorescence microscopy, en route toward detailed investigations on their biological interactions.

  18. Efficiency of endoscopy units can be improved with use of discrete event simulation modeling

    PubMed Central

    Sauer, Bryan G.; Singh, Kanwar P.; Wagner, Barry L.; Vanden Hoek, Matthew S.; Twilley, Katherine; Cohn, Steven M.; Shami, Vanessa M.; Wang, Andrew Y.

    2016-01-01

    Background and study aims: The projected increased demand for health services obligates healthcare organizations to operate efficiently. Discrete event simulation (DES) is a modeling method that allows for optimization of systems through virtual testing of different configurations before implementation. The objective of this study was to identify strategies to improve the daily efficiencies of an endoscopy center with the use of DES. Methods: We built a DES model of a five procedure room endoscopy unit at a tertiary-care university medical center. After validating the baseline model, we tested alternate configurations to run the endoscopy suite and evaluated outcomes associated with each change. The main outcome measures included adequate number of preparation and recovery rooms, blocked inflow, delay times, blocked outflows, and patient cycle time. Results: Based on a sensitivity analysis, the adequate number of preparation rooms is eight and recovery rooms is nine for a five procedure room unit (total 3.4 preparation and recovery rooms per procedure room). Simple changes to procedure scheduling and patient arrival times led to a modest improvement in efficiency. Increasing the preparation/recovery rooms based on the sensitivity analysis led to significant improvements in efficiency. Conclusions: By applying tools such as DES, we can model changes in an environment with complex interactions and find ways to improve the medical care we provide. DES is applicable to any endoscopy unit and would be particularly valuable to those who are trying to improve on the efficiency of care and patient experience. PMID:27853739

  19. Endoscopy and General Surgery - Parts of the Same Activity.

    PubMed

    Doran, Horia; Pătraşcu, Traian

    2016-01-01

    In general and digestive surgical departments, an accurate diagnosis and appropriate treatment of our patients require a wide and continuous access to endoscopy. As many surgical clinics have already developed their own endoscopy units, we plead for the future presence of at least 1 or 2 surgeons, board certified in endoscopy, in every surgical department. We have retrospectively analyzed the activity of the endoscopic unit as a part of the Surgical Clinic of "œDr. I. Cantacuzino" Clinical Hospital since 2007, when it was settled, and its benefits, regarding a higher accessibility for our patients and a reliable support for all the doctors. The number of procedures has increased constantly, from 137, performed by 2 surgeons in 2007 to 1546, in 2015, when 7 surgeons were able to get involved in endoscopic procedures, on a 24/7 schedule. The etiological diagnosis of gastrointestinal hemorrhages, the early detection of gastric, colonic and upper rectal tumors, the follow-up of oncologic patients are only a few of the fields in which endoscopy proved its benefits. Furthermore, surgeons have the practical training and the legal board certification for the approach and treatment of complications. An increased number of surgeons who have also board certification in endoscopy cannot be but very useful. The best way to accomplish this goal would be the inclusion of a digestive endoscopy module during the training program of all future general surgeons. Celsius.

  20. The Lens Capsule

    PubMed Central

    Danysh, Brian P.; Duncan, Melinda K.

    2009-01-01

    The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892

  1. Current status of cleaning and disinfection for gastrointestinal endoscopy in China: a survey of 122 endoscopy units.

    PubMed

    Zhang, Xiuli; Kong, Jinyan; Tang, Ping; Wang, Shufang; Hyder, Qurratulain; Sun, Gang; Zhang, Rugang; Yang, Yunsheng

    2011-04-01

    Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. To investigate cleaning and disinfection practice in China. A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China. One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (<5000 procedures/year), the high-workload units (≥5000 procedures/year) had a significantly higher number of gastrointestinal endoscopes (25.8 ± 3.6 vs. 4.7 ± 1.8, p < 0.01) and the higher possessing rate of automated endoscope reprocessors (43.9% vs. 3.1%, p<0.01). Glutaraldehyde was the most commonly employed disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious disease patients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently. Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Magneto-responsive alginate capsules.

    PubMed

    Degen, Patrick; Zwar, Elena; Schulz, Imke; Rehage, Heinz

    2015-05-20

    Upon incorporation of magnetic nanoparticles (mNPs) into gels, composite materials called ferrogels are obtained. These magneto-responsive systems have a wide range of potential applications including switches and sensors as well as drug delivery systems. In this article, we focus on the properties of calcium alginate capsules, which are widely used as carrier systems in medicine and technology. We studied the incorporation of different kinds of mNPs in matrix capsules and in the core and the shell of hollow particles. We found out that not all particle-alginate or particle-CaCl2 solution combinations were suitable for a successful capsule preparation on grounds of a destabilization of the nanoparticles or the polymer. For those systems allowing the preparation of switchable beads or capsules, we systematically studied the size and microscopic structure of the capsules, their magnetic behavior and mechanical resistance.

  3. Oxygen Fugacity in Large Metal Capsules

    NASA Astrophysics Data System (ADS)

    Faul, U.; Cline, C. J., II; Jackson, I.; Berry, A.

    2016-12-01

    During experiments with iron bearing silicates, equilibration between metal capsules and sample interior depends on diffusion of Fe if the capsule composition is not initially in equilibrium with the sample composition. For example, placing Pt or Ni capsules in contact with Fe-bearing olivine leads to Fe-loss from the olivine. In a fully equilibrated system the Fe contents of coexisting metal capsule and olivine reflect the oxygen fugacity (fO2) of the system. Experiments were conducted with olivine encapsulated or wrapped in four different metals (Fe, Ni70Fe30, Ni and Pt) to determine the fO2 in the cm-sized samples used for deformation and seismic property experiments. Small Pt particles mixed with olivine powder were used as fO2 sensors in the interior of the capsules. The results show an ordering of the fO2 in the interior that is consistent with the enclosing metals, i.e. the fO2 is lowest in a Fe capsule and highest in a Pt capsule. However, fO2 values in the more oxidizing metal capsules are substantially below their respective metal-oxide buffers. For example, solgel olivine encapsulated in Ni has an oxygen fugacity that is more than three orders of magnitude below Ni-NiO at 1200C and 0.3 GPa. The fO2 in a capsule interior is therefore to some extent self-buffering and only moderately influenced by the composition of the capsule. While the Pt particles in the interior are equilibrated, Fe gradients from the interior up to the Pt and Ni sample-capsule interfaces show that Fe loss into the capsules is diffusion limited. The fO2 at the interface also has implications for the water retention in unbuffered capsules. We infer that relatively high fO2 and hence fH2O observed adjacent to Pt capsules enables retention of water in these capsules, but the fO2 adjacent to Ni capsules is too low and water is lost.

  4. Helical CT scan with 2D and 3D reconstructions and virtual endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children.

    PubMed

    Yunus, Mahira

    2012-11-01

    To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.

  5. Polydopamine-coated capsules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  6. Diagnostic and Therapeutic Yield of Endoscopy in Patients with Elevated INR and Gastrointestinal Bleeding.

    PubMed

    Peloquin, Joanna M; Seraj, Siamak M; King, Lindsay Y; Campbell, Emily J; Ananthakrishnan, Ashwin N; Richter, James M

    2016-06-01

    Gastrointestinal bleeding is a well-known risk of systemic anticoagulation. However, bleeding in the setting of supratherapeutic anticoagulation may have a milder natural history than unprovoked bleeding. It is a common clinical gestalt that endoscopy is common, but bleeding source identification or intervention is uncommon, yet few data exist to inform this clinical impression. Consequently, we sought to examine our institutional experience with gastrointestinal bleeding in the setting of supratherapeutic international normalized ratio (INR) with the aim of identifying predictors of endoscopically identifiable lesions, interventions, and outcomes. A retrospective review was conducted at a tertiary referral academic medical center to identify patients presenting with gastrointestinal bleeding in the setting of warfarin and a supratherapeutic INR (>3.5) who underwent an endoscopic procedure. Relevant clinical covariates, endoscopic findings, need for intervention, and outcomes were collected by review of the medical record. Logistic regression adjusting for potential confounders identified predictors of endoscopically significant lesions as well as intervention and outcomes. A total of 134 patients with INR 3.5 or greater (mean 5.5, range 3.5-17.1) presented with symptoms of gastrointestinal bleeding, most commonly as melena or symptomatic anemia. Antiplatelet agents were used by 54% of patients, and 60% of patients were on concomitant acid suppression on admission. Procedures included esophagogastroduodenoscopy (upper endoscopy; EGD) (n = 128), colonoscopy (n = 73), and video capsule endoscopy (n = 32). Active bleeding at first EGD or colonoscopy was found in only 19 patients (18%), with endoscopic intervention in only 26 patients (25%). At a critical threshold of INR 7.5 at presentation, the likelihood of finding an endoscopically significant lesion fell to <20%. On multivariate logistic regression, concomitant antiplatelet therapy (odds ratio [OR] 2.59; 95

  7. From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.

    PubMed

    Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas

    2016-12-01

    Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.

  8. The effect of upper gastrointestinal system endoscopy process on serum oxidative stress levels.

    PubMed

    Turan, Mehmet Nuri; Aslan, Mehmet; Bolukbas, Filiz Fusun; Bolukbas, Cengiz; Selek, Sahbettin; Sabuncu, Tevfik

    2016-12-01

    Some authors have investigated the effects of oxidative stress in some process such as undergoing laparoscopic. However, the effect of upper gastrointestinal system endoscopy process on oxidative stress is unclear. We evaluated the short-term effect of upper gastrointestinal system endoscopy process on oxidative stress. Thirty patients who underwent endoscopy process and 20 healthy controls were enrolled in the prospective study. Serum total antioxidant capacity and total oxidant status measurements were measured before and after endoscopy process. The ratio percentage of total oxidant status to total antioxidant capacity was regarded as oxidative stress index. Before endoscopy process, serum total antioxidant capacity levels were higher, while serum total oxidant status levels and oxidative stress index values were lower in patients than controls, but this difference was not statistically significant (all, p > 0.05). After endoscopy process, serum total antioxidant capacity and total oxidant status levels were significantly higher in patients than before endoscopy process (both, p < 0.05). However, oxidative stress index values were slight higher in patients but this difference was not statistically significant (p > 0.05). We observed that serum TAC and TOS levels were increased in patients who underwent endoscopy process after endoscopy process. However, short-time upper gastrointestinal system endoscopy process did not cause an important change in the oxidative stress index. Further studies enrolling a larger number of patients are required to clarify the results obtained here.

  9. Does ear endoscopy provide advantages in the outpatient management of open mastoidectomy cavities?

    PubMed

    Freire, Gustavo Subtil Magalhães; Sampaio, Andre Luiz Lopes; Lopes, Rafaela Aquino Fernandes; Nakanishi, Márcio; de Oliveira, Carlos Augusto Costa Pires

    2018-01-01

    To evaluate the use of ear endoscopy in the postoperative management of open mastoidectomy cavities, and to test whether ear endoscopy improves inspection and cleaning compared with ear microscopy. Prospective study. Thirty-two ears were divided into two groups: group 1, examination and cleaning of mastoid cavities under endoscopic visualization after microscopic standard ear cleaning; group 2, examination and cleaning of mastoid cavities under microscopic visualization after endoscope-assisted ear cleaning. We assessed the ability of each method to provide exposure and facilitate cleaning, comparing the benefits of microscopy and endoscopy when used sequentially and vice-versa. Endoscopy provided additional benefits for exposure in 61.1% of cases and cleaning in 66.7%. Microscopy provided no additional benefits in terms of exposure in any case, and provided added benefit for cleaning in only 21.4% of cases. For outpatient postoperative care of open mastoidectomy cavities, ear endoscopy provides greater benefit over ear microscopy than vice-versa. In over half of all cases, endoscopy was able to expose areas not visualized under the microscope. Furthermore, in two-thirds of cases, endoscopy enabled removal of material that could not be cleared under microscopy. Ear endoscopy was superior to microscopy in terms of enabling exposure and cleaning of hard-to-reach sites, due to its wider field of vision. Ear endoscopy is a feasible technique for the postoperative management of open mastoidectomy cavities. Ear endoscopy provided superior advantages in terms of exposure and aural cleaning compared with microscopy.

  10. The Past, Present, and Future of Image-Enhanced Endoscopy

    PubMed Central

    Jang, Jae-Young

    2015-01-01

    Despite the remarkable progress recently made to enhance the resolution of white-light endoscopy, detection, and diagnosis of premalignant lesions, such as adenomas and subtle early-stage cancers, remains a great challenge. As for example, although chromoendoscopy, such as endoscopy using indigo carmine, is useful for the early diagnosis of subtle lesions, the technique presents various disadvantages ranging from the time required for spray application of the dye and suctioning of excess dye to the increased difficulty in identifying lesions in the presence of severe inflammation and obstruction of visual field due to the pooling of solution in depressed-type lesions. To overcome these diagnostic problems associated with chromoendoscopy, research has focused on the development of endoscopes based on new optical technologies. Several types of image-enhanced endoscopy methods have recently been presented. In particular, image-enhanced endoscopy has emerged as a new paradigm for the diagnosis of gastrointestinal disorders. Image-enhanced endoscopes provide high-contrast images of lesions by means of optical or electronic technologies, including the contrast enhancement of the mucosal surface and of blood vessels. Chromoendoscopy, narrow-band imaging, i-SCAN, and flexible spectral imaging color enhancement are representative examples of image-enhanced endoscopy discussed in this paper. PMID:26668791

  11. Evaluation of a multimedia information system for endoscopy

    NASA Astrophysics Data System (ADS)

    Enning, C. John W.; Siersema, Peter D.; van Blankenstein, Mark; van Boven, Gert-Jan; van Gennip, Elisabeth M.

    1996-05-01

    In a cooperation between the University Hospital Rotterdam (AZR) and HISCOM, HIS supplier, a multimedia information system for endoscopy (ENSIS) has been developed in a project funded by the Dutch Ministry of Health Care. An integral part of this project was an evaluation of costs and effects of this system. The system has been implemented on the gastroenterology department and the internal medicine ward in the AZR. The results indicate that the anatomical knowledge of requesting physicians improved with the system. Both the response time and availability of endoscopy images improved greatly. Because of the use of off-the-shelve technology (possible because of the relatively small resolution requirements of endoscopy images) ENSIS can be implemented at relatively low costs.

  12. Intelligent visual localization of wireless capsule endoscopes enhanced by color information.

    PubMed

    Dimas, George; Spyrou, Evaggelos; Iakovidis, Dimitris K; Koulaouzidis, Anastasios

    2017-10-01

    Wireless capsule endoscopy (WCE) is performed with a miniature swallowable endoscope enabling the visualization of the whole gastrointestinal (GI) tract. One of the most challenging problems in WCE is the localization of the capsule endoscope (CE) within the GI lumen. Contemporary, radiation-free localization approaches are mainly based on the use of external sensors and transit time estimation techniques, with practically low localization accuracy. Latest advances for the solution of this problem include localization approaches based solely on visual information from the CE camera. In this paper we present a novel visual localization approach based on an intelligent, artificial neural network, architecture which implements a generic visual odometry (VO) framework capable of estimating the motion of the CE in physical units. Unlike the conventional, geometric, VO approaches, the proposed one is adaptive to the geometric model of the CE used; therefore, it does not require any prior knowledge about and its intrinsic parameters. Furthermore, it exploits color as a cue to increase localization accuracy and robustness. Experiments were performed using a robotic-assisted setup providing ground truth information about the actual location of the CE. The lowest average localization error achieved is 2.70 ± 1.62 cm, which is significantly lower than the error obtained with the geometric approach. This result constitutes a promising step towards the in-vivo application of VO, which will open new horizons for accurate local treatment, including drug infusion and surgical interventions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Transnasal endoscopy: Technical considerations, advantages and limitations.

    PubMed

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-02-16

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes.

  14. Transnasal endoscopy: Technical considerations, advantages and limitations

    PubMed Central

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-01-01

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes. PMID:24567791

  15. Status Report on Irradiation Capsules Designed to Evaluate FeCrAl-UO 2 Interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Field, Kevin G.; Howard, Richard H.

    This status report provides the background and current status of a series of irradiation capsules that were designed and are being built to test the interactions between candidate FeCrAl cladding for enhanced accident tolerant applications and prototypical enriched commercial UO 2 fuel in a neutron radiation environment. These capsules will test the degree, if any, of fuel cladding chemical interactions (FCCI) between FeCrAl and UO 2. The capsules are to be irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory to burn-ups of 10, 30, and 50 GWd/MT with a nominal target temperature at the interfaces between themore » pellets and clad of 350°C.« less

  16. Feasibility of transnasal endoscopy in screening for esophageal and gastric varices in patients with chronic liver disease

    PubMed Central

    de Faria, Anderson Antônio; Dias, Carlos Alberto Freitas; Dias Moetzsohn, Luciana; de Castro Carvalho, Silas; Ferrari, Tereza Abreu; Nunes Arantes, Vitor

    2017-01-01

    Background and study aims  Screening for esophageal and gastric varices is indicated for patients with portal hypertension or cirrhosis. Typically, conventional endoscopy is used; however, the need for sedation increases the costs and risks, especially in cirrhotic patients. Use of transnasal endoscopy with an ultrathin endoscope enables study of the upper gastrointestinal tract without the need for sedation. The objective of this study is to evaluate the feasibility of transnasal endoscopy in screening for esophageal and gastric varices in patients with chronic liver disease. Patients and methods  This was a prospective study in which transnasal endoscopy was carried out in patients with cirrhosis or portal hypertension who had indications for screening of esophageal and gastric varices. The following variables were evaluated: demographical data, duration of procedure, patient tolerance and acceptance, adverse events (AEs), endoscopic findings and interobserver agreement related to portal hypertension alterations ( kappa index). Results  A total of 50 patients entered the study. The most common cause of liver disease was chronic viral hepatitis (66 %). Among the cirrhotic patients, most of the patients were Child-Pugh A (74 %). In 5 patients (10 %), nasal intubation was not possible. Two patients (4 %) experienced minor epistaxis. Tolerance was excellent or good in 92 % according with a visual analogic scale. In 16 patients (32 %), esophageal varices were detected and in 2 patients (4 %) gastric varices were detected. The mean duration of the procedure was 7 minutes. Conclusions  Transnasal endoscopy is feasible, effective and well tolerated for screening of esophageal and gastric varices in patients with chronic liver disease. It can be performed in outpatient clinics safely and without the use of sedation. PMID:28691048

  17. Evaluating quality in endoscopy.

    PubMed

    Pohl, Heiko

    2017-06-01

    Despite an increasing number of publications and suggested quality measures, evaluating quality in endoscopy remains a challenge. Most quality measures are process measures and lack evidence for an association with clinically important outcomes. Furthermore, most measure focus on procedural aspects. Patients' expectations, cultural values, and work setting also affect quality, but are less often considered. The aim of this article is to broaden the view on quality assessment. Here, quality is viewed from four perspectives: an individual patient perspective, which considers expectations and personal values; a cultural perspective, which encompasses cultural values and norms; an individual care perspective, which includes how an individual patient is being treated; and a societal perspective, which sets the stage for provided care. The article concludes with a proposal to consider bundled composite measures as a path to a simple yet comprehensive approach to assessing and measuring quality in endoscopy. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Paediatric Gastrointestinal Endoscopy: European Society for Paediatric Gastroenterology Hepatology and Nutrition and European Society of Gastrointestinal Endoscopy Guidelines.

    PubMed

    Thomson, Mike; Tringali, Andrea; Dumonceau, Jean-Marc; Tavares, Marta; Tabbers, Merit M; Furlano, Raoul; Spaander, Manon; Hassan, Cesare; Tzvinikos, Christos; Ijsselstijn, Hanneke; Viala, Jérôme; Dall'Oglio, Luigi; Benninga, Marc; Orel, Rok; Vandenplas, Yvan; Keil, Radan; Romano, Claudio; Brownstone, Eva; Hlava, Štěpán; Gerner, Patrick; Dolak, Werner; Landi, Rosario; Huber, Wolf D; Everett, Simon; Vecsei, Andreas; Aabakken, Lars; Amil-Dias, Jorge; Zambelli, Alessandro

    2017-01-01

    This guideline refers to infants, children, and adolescents ages 0 to 18 years. The areas covered include indications for diagnostic and therapeutic esophagogastroduodenoscopy and ileocolonoscopy; endoscopy for foreign body ingestion; corrosive ingestion and stricture/stenosis endoscopic management; upper and lower gastrointestinal bleeding; endoscopic retrograde cholangiopancreatography; and endoscopic ultrasonography. Percutaneous endoscopic gastrostomy and endoscopy specific to inflammatory bowel disease has been dealt with in other guidelines and are therefore not mentioned in this guideline. Training and ongoing skill maintenance are to be dealt with in an imminent sister publication to this.

  19. Mobile-Cloud Assisted Video Summarization Framework for Efficient Management of Remote Sensing Data Generated by Wireless Capsule Sensors

    PubMed Central

    Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook

    2014-01-01

    Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data. PMID:25225874

  20. Mobile-cloud assisted video summarization framework for efficient management of remote sensing data generated by wireless capsule sensors.

    PubMed

    Mehmood, Irfan; Sajjad, Muhammad; Baik, Sung Wook

    2014-09-15

    Wireless capsule endoscopy (WCE) has great advantages over traditional endoscopy because it is portable and easy to use, especially in remote monitoring health-services. However, during the WCE process, the large amount of captured video data demands a significant deal of computation to analyze and retrieve informative video frames. In order to facilitate efficient WCE data collection and browsing task, we present a resource- and bandwidth-aware WCE video summarization framework that extracts the representative keyframes of the WCE video contents by removing redundant and non-informative frames. For redundancy elimination, we use Jeffrey-divergence between color histograms and inter-frame Boolean series-based correlation of color channels. To remove non-informative frames, multi-fractal texture features are extracted to assist the classification using an ensemble-based classifier. Owing to the limited WCE resources, it is impossible for the WCE system to perform computationally intensive video summarization tasks. To resolve computational challenges, mobile-cloud architecture is incorporated, which provides resizable computing capacities by adaptively offloading video summarization tasks between the client and the cloud server. The qualitative and quantitative results are encouraging and show that the proposed framework saves information transmission cost and bandwidth, as well as the valuable time of data analysts in browsing remote sensing data.

  1. Polyelectrolyte capsules preloaded with interconnected alginate matrix: An effective capsule system for encapsulation and release of macromolecules.

    PubMed

    Sundaramurthy, Anandhakumar; Sundramoorthy, Ashok K

    2018-02-01

    In recent years, the design of stimuli-responsive hollow polymeric capsules is of tremendous interest for the scientific community because of the broad application of these capsules in the biomedical field. The use of weak polyelectrolytes as layer components for capsule fabrication is especially interesting as it results in hollow capsules that show unique release characteristics under physiological conditions. In this work, a methodology to prepare sub-micron sized alginate doped calcium carbonate (CaCO 3 ) particles through controlled precipitation in the presence of alginate is reported. Hollow capsules obtained by Layer-by-Layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) are showing an interconnected alginate matrix in the interior of the capsules. Investigations showed that the presence of alginate matrix enhances the encapsulation of cationic molecules (e.g. doxorubicin hydrochloride) manifold by charge controlled attraction mechanism. Capsule permeability investigated by confocal laser scanning microscopy revealed that the transformation from an open state to closed state is accompanied by an intermediate state where capsules are neither open nor closed. Furthermore, time dependent study indicated that the encapsulation process is linear as a function of time. The cell viability experiments demonstrated excellent biocompatibility of hollow capsules with mouse embryonic fibroblast cells. Anticancer investigations showed that DOX loaded capsules have significant anti-proliferative characteristics against HeLa cells. Such capsules have high potential for use as drug carrier for cationic drugs in cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Therapeutic upper gastrointestinal tract endoscopy in Paediatric Gastroenterology

    PubMed Central

    Rahman, Imdadur; Patel, Praful; Boger, Philip; Rasheed, Shahnawaz; Thomson, Mike; Afzal, Nadeem Ahmad

    2015-01-01

    Since the first report of use of endoscopy in children in the 1970s, there has seen an exponential growth in published experience and innovation in the field. In this review article we focus on modern age therapeutic endoscopy practice, explaining use of traditional as well as new and innovative techniques, for diagnosis and treatment of diseases in the paediatric upper gastrointestinal tract. PMID:25789087

  3. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate-the learning curve for endoscopy training

    PubMed Central

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-01-01

    BACKGROUND: Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. OBJECTIVE: To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. METHODS: The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists/surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The ‘Endoscopy Task Load Index’ was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. RESULTS: From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. DISCUSSION: The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers. PMID:24619638

  4. Bioavailability study of dronabinol oral solution versus dronabinol capsules in healthy volunteers

    PubMed Central

    Parikh, Neha; Kramer, William G; Khurana, Varun; Cognata Smith, Christina; Vetticaden, Santosh

    2016-01-01

    Background Dronabinol, a pharmaceutical Δ-9-tetrahydrocannabinol, was originally developed as an oral capsule. This study evaluated the bioavailability of a new formulation, dronabinol oral solution, versus a dronabinol capsule formulation. Methods In an open-label, four-period, single-dose, crossover study, healthy volunteers were randomly assigned to one of two treatment sequences (T-R-T-R and R-T-R-T; T = dronabinol 4.25 mg oral solution and R = dronabinol 5 mg capsule) under fasted conditions, with a minimum 7-day washout period between doses. Analyses were performed on venous blood samples drawn 15 minutes to 48 hours postdose, and dronabinol concentrations were assayed by liquid chromatography–tandem mass spectrometry. Results Fifty-one of 52 individuals had pharmacokinetic data for analysis. The 90% confidence interval of the geometric mean ratio (oral solution/capsule) for dronabinol was within the 80%–125% bioequivalence range for area under the plasma concentration–time curve (AUC) from time zero to last measurable concentration (AUC0–t) and AUC from time zero to infinity (AUC0–∞). Maximum plasma concentration was also bioequivalent for the two dronabinol formulations. Intraindividual variability in AUC0–∞ was >60% lower for dronabinol oral solution 4.25 mg versus dronabinol capsule 5 mg. Plasma dronabinol concentrations were detected within 15 minutes postdose in 100% of patients when receiving oral solution and in <25% of patients when receiving capsules. Conclusion Single-dose dronabinol oral solution 4.25 mg was bioequivalent to dronabinol capsule 5 mg under fasted conditions. Dronabinol oral solution formulation may provide an easy-to-swallow administration option with lower intraindividual variability as well as more rapid absorption versus dronabinol capsules. PMID:27785111

  5. Premedication with simethicone and N-acetylcysteine in improving visibility during upper endoscopy: a double-blind randomized trial.

    PubMed

    Elvas, Luís; Areia, Miguel; Brito, Daniel; Alves, Susana; Saraiva, Sandra; Cadime, Ana T

    2017-02-01

    Background and study aim  Upper endoscopy is the most common method for the diagnosis of upper gastrointestinal tract diseases. The aim of this study was to determine whether premedication with simethicone or N -acetylcysteine improves mucosal visualization during upper endoscopy. Patients and methods  This was a randomized, double-blind, placebo-controlled study of 297 patients scheduled for upper endoscopy who were premedicated 15 - 30 minutes before the procedure with: 100 mL of water (placebo, group A); water plus 100 mg simethicone (group B); water plus 100 mg simethicone plus 600 mg N -acetylcysteine (group C). The primary outcome measure was the quality of mucosal visualization (score: excellent, adequate or inadequate). Results  The addition of simethicone (group B) or simethicone plus N -acetylcysteine to the water (group C) improved the visualization scores of endoscopies compared with water alone (group A). In particular, groups B and C produced a significantly higher percentage of endoscopies with excellent visualization for the esophagus (91.1 % and 86.7 %, respectively, vs. 71.4 % in group A; P  < 0.001) and stomach (76.2 % and 74.5 % vs. 38.8 % in group A; P  < 0.001). For the duodenum, the use of simethicone also showed an increase in the endoscopies with excellent visualization compared with water alone (85.1 % vs. 73.5 %; P  = 0.042). There were no significant differences in scores between groups B and C or between gastric scores in patients with previous subtotal gastrectomy (B and C vs. A): 60.0 % and 42.1 % vs. 28.6 % ( P  = 0.14). The rate of reported lesions was higher in group B but without statistical significance. Conclusions  Premedication with simethicone resulted in better mucosal visibility. Such premedication might improve diagnostic yield, and should be considered for standard practice. Trial registered at ClinicalTrials.gov (NCT02357303). © Georg Thieme Verlag KG Stuttgart

  6. Advanced endoscopic imaging: European Society of Gastrointestinal Endoscopy (ESGE) Technology Review.

    PubMed

    East, James E; Vleugels, Jasper L; Roelandt, Philip; Bhandari, Pradeep; Bisschops, Raf; Dekker, Evelien; Hassan, Cesare; Horgan, Gareth; Kiesslich, Ralf; Longcroft-Wheaton, Gaius; Wilson, Ana; Dumonceau, Jean-Marc

    2016-11-01

    Background and aim: This technical review is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the utilization of advanced endoscopic imaging in gastrointestinal (GI) endoscopy. Methods: This technical review is based on a systematic literature search to evaluate the evidence supporting the use of advanced endoscopic imaging throughout the GI tract. Technologies considered include narrowed-spectrum endoscopy (narrow band imaging [NBI]; flexible spectral imaging color enhancement [FICE]; i-Scan digital contrast [I-SCAN]), autofluorescence imaging (AFI), and confocal laser endomicroscopy (CLE). The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was adopted to define the strength of recommendation and the quality of evidence. Main recommendations: 1. We suggest advanced endoscopic imaging technologies improve mucosal visualization and enhance fine structural and microvascular detail. Expert endoscopic diagnosis may be improved by advanced imaging, but as yet in community-based practice no technology has been shown consistently to be diagnostically superior to current practice with high definition white light. (Low quality evidence.) 2. We recommend the use of validated classification systems to support the use of optical diagnosis with advanced endoscopic imaging in the upper and lower GI tracts (strong recommendation, moderate quality evidence). 3. We suggest that training improves performance in the use of advanced endoscopic imaging techniques and that it is a prerequisite for use in clinical practice. A learning curve exists and training alone does not guarantee sustained high performances in clinical practice. (Weak recommendation, low quality evidence.) Conclusion: Advanced endoscopic imaging can improve mucosal visualization and endoscopic diagnosis; however it requires training and the use of validated classification systems. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Enteroscopy in the diagnosis and management of celiac disease.

    PubMed

    Rondonotti, Emanuele; Villa, Federica; Saladino, Valeria; de Franchis, Roberto

    2009-07-01

    Esophagogastroduodenoscopy (EGD) with 3 to 6 biopsies in the descending duodenum is the gold standard for the diagnosis of celiac disease. At the time of the first diagnosis of celiac disease, an extensive evaluation of the small bowel is not recommended. However, video capsule endoscopy, because of its good sensitivity and specificity in recognizing the Endoscopic features of celiac disease, can be considered a valid alternative to EGD in patients unable or unwilling to undergo EGD with biopsies. Capsule endoscopy is also a possible option in selected cases with strong suspicion of celiac disease but negative first-line tests. In evaluating patients with refractory or complicated celiac disease, in whom a complete evaluation of the small bowel is mandatory (at least in refractory celiac disease type II patients) because of the possible presence of complications beyond the reach of conventional endoscopes, both capsule endoscopy and balloon-assisted enteroscopy have been found to be helpful. In these patients, capsule endoscopy offers several advantages: it is well tolerated, it allows inspection of the entire small bowel, and it is able to recognize subtle mucosal changes. However, in this setting, capsule endoscopy should ideally be coupled with imaging techniques that provide important information about the thickness of the wall of the intestine and about extraluminal abnormalities. Although deep enteroscopy (such as balloon enteroscopy) is expensive, time-consuming, and potentially risky in these frail patients, they may have a key role, because they make it possible to take tissue samples from deep in the small intestine.

  8. International Digestive Endoscopy Network 2014: Turnpike to the Future

    PubMed Central

    Kim, Eun Young; Kwon, Kwang An; Choi, Il Ju; Ryu, Ji Kon

    2014-01-01

    Social networks are useful in the study of relationships between individuals or entire populations, and the ties through which any given social unit connects. Those represent the convergence of the various social contacts of that unit. Consequently, the term "social networking service" (SNS) became extremely familiar. Similar to familiar SNSs, International Digestive Endoscopy Network (IDEN) 2014 was based on an international network composed of an impressive 2-day scientific program dealing with a variety of topics for gastrointestinal (GI) diseases, which connects physicians and researchers from all over the world. The scientific programs included live endoscopic demonstrations and provided cutting-edge information and practice tips as well as the latest advances concerning upper GI, lower GI, and pancreatobiliary endoscopy. IDEN 2014 featured American Society for Gastrointestinal Endoscopy-Korean Society of Gastrointestinal Endoscopy (ASGE-KSGE)-joint sessions prepared through cooperation between ASGE and KSGE. Furthermore, IDEN 2014 provided a special program for young scientists called the 'Asian Young Endoscopist Award Forum' to foster networks, with many young endoscopists from Asian countries taking an active interest and participation. PMID:25324994

  9. International digestive endoscopy network 2014: turnpike to the future.

    PubMed

    Kim, Eun Young; Kwon, Kwang An; Choi, Il Ju; Ryu, Ji Kon; Hahm, Ki Baik

    2014-09-01

    Social networks are useful in the study of relationships between individuals or entire populations, and the ties through which any given social unit connects. Those represent the convergence of the various social contacts of that unit. Consequently, the term "social networking service" (SNS) became extremely familiar. Similar to familiar SNSs, International Digestive Endoscopy Network (IDEN) 2014 was based on an international network composed of an impressive 2-day scientific program dealing with a variety of topics for gastrointestinal (GI) diseases, which connects physicians and researchers from all over the world. The scientific programs included live endoscopic demonstrations and provided cutting-edge information and practice tips as well as the latest advances concerning upper GI, lower GI, and pancreatobiliary endoscopy. IDEN 2014 featured American Society for Gastrointestinal Endoscopy-Korean Society of Gastrointestinal Endoscopy (ASGE-KSGE)-joint sessions prepared through cooperation between ASGE and KSGE. Furthermore, IDEN 2014 provided a special program for young scientists called the 'Asian Young Endoscopist Award Forum' to foster networks, with many young endoscopists from Asian countries taking an active interest and participation.

  10. PREVALENCE OF HELICOBACTER PYLORI TEN YEARS AGO COMPARED TO THE CURRENT PREVALENCE IN PATIENTS UNDERGOING UPPER ENDOSCOPY

    PubMed Central

    FRUGIS, Sandra; CZECZKO, Nicolau Gregori; MALAFAIA, Osvaldo; PARADA, Artur Adolfo; POLETTI, Paula Bechara; SECCHI, Thiago Festa; DEGIOVANI, Matheus; RAMPANAZZO-NETO, Alécio; D´AGOSTINO, Mariza D.

    2016-01-01

    ABSTRACT Background: Helicobacter pylori has been extensively studied since 1982 it is estimated that 50% of the world population is affected. The literature lacks studies that show the change of its prevalence in the same population over time. Aim: To compare the prevalence of H. pylori in 10 years interval in a population that was submitted to upper endoscopy in the same endoscopy service. Method: Observational, retrospective and cross-sectional study comparing the prevalence of H. pylori in two samples with 10 years apart (2004 and 2014) who underwent endoscopy with biopsy and urease. Patients were studied in three consecutive months of 2004, compared to three consecutive months of 2014. The total number of patients was 2536, and 1406 in 2004 and 1130 in 2014. Results: There were positive for H. pylori in 17 % of the sample as a whole. There was a significant decrease in the prevalence from 19.3% in 2004 to 14.1% in 2014 (p<0.005). Conclusion: There was a 5.2% reduction in the prevalence of H. pylori comparing two periods of three consecutive months with 10 years apart in two equivalent population samples. PMID:27759776

  11. Improving the timeliness of procedures in a pediatric endoscopy suite.

    PubMed

    Tomer, Gitit; Choi, Steven; Montalvo, Andrea; Sutton, Sheila; Thompson, John; Rivas, Yolanda

    2014-02-01

    Pediatric endoscopic procedures are essential in the evaluation and treatment of gastrointestinal diseases in children. Although pediatric endoscopists are greatly interested in increasing efficiency and through-put in pediatric endoscopy units, there is scarcely any literature on this critical process. The goal of this study was to improve the timeliness of pediatric endoscopy procedures at Children's Hospital at Montefiore. In June 2010, a pediatric endoscopy quality improvement initiative was formed at Children's Hospital at Montefiore. We identified patient-, equipment-, and physician-related causes for case delays. Pareto charts, cause and effect diagrams, process flow mapping, and statistical process control charts were used for analysis. From June 2010 to December 2012, we were able to significantly decrease the first case endoscopy delay from an average of 17 to 10 minutes (P < .001), second case delay from 39 to 25 minutes (P = .01), third case delay from 61 to 45 minutes (P = .05), and fourth case delay from 79 to 51 minutes (P = .05). Total delay time decreased from 196 to 131 minutes, resulting in a reduction of 65 minutes (P = .02). From June 2010 to August 2011 (preintervention period), an average of 36% of first endoscopy cases started within 5 minutes, 51% within 10 minutes, and 61% within 15 minutes of the scheduled time. From September 2011 to December 2012 (postintervention period), the percentage of cases starting within 5 minutes, 10 minutes, and 15 minutes increased to 47% (P = .07), 61% (P = .04), and 79% (P = .01), respectively. Applying quality improvement methods and tools helped improve pediatric endoscopy timeliness and significantly decreased total delays.

  12. Review of musculoskeletal injuries and prevention in the endoscopy practitioner.

    PubMed

    Harvin, Glenn

    2014-08-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces.

  13. Review of Musculoskeletal Injuries and Prevention in the Endoscopy Practitioner

    PubMed Central

    2014-01-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces. PMID:24798940

  14. Chromoendoscopy and magnification endoscopy in Barrett's esophagus.

    PubMed

    Connor, Michael J; Sharma, Prateek

    2003-04-01

    Chromoendoscopy and magnification endoscopy appear to be a valuable adjuncts for the detection and classification of BE. These techniques may also prove to be useful aids in surveillance protocols for identifying dysplastic epithelium or early cancer within a segment of BE. Ideally, the use of these techniques would enable the endoscopist to rule in or out the presence of IM and of dysplastic or cancerous epithelium by obtaining only a minimal number of targeted biopsy specimens, or potentially performing no biopsies at all. This could transform upper endoscopy into a much more effective screening and surveillance tool for BE. Several problems currently exist for the use of chromoendoscopy for BE. Results of studies reporting the accuracy of chromoendoscopy remain mixed,and are likely explained by the wide range of techniques and materials used in the investigations. Staining adds several steps, and likely several minutes, to an upper endoscopy. Staining within the esophagus is often patchy and uneven. In addition, poor spraying technique exaggerates the irregular uptake by the mucosa. There is a high false-positive rate when staining gastric-type epithelium and denuded epithelium. Areas of dysplasia or cancer may take up stain in an irregular manner, or may not stain at all. Chromoendoscopy is a relatively new technique in the management of BE and depends on the skill and experience of the endoscopist. Magnification, however, only allows the endoscopist to observe small areas of mucosa at a time, increasing the overall complexity and length of the procedure. The learning curve for this procedure is relatively short, however, and endoscopists can usually become proficient in the technique quickly. Currently, the greatest body of literature exists concerning the use of methylene blue for diagnosing BE. At the present time, chromoendoscopy and magnification endoscopy appear to be most beneficial in detecting IM in short segments of esophageal columnar

  15. The European Society of Gastrointestinal Endoscopy Quality Improvement Initiative: developing performance measures.

    PubMed

    Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul

    2016-02-01

    The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision. ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients.

  16. Stennis time capsule

    NASA Image and Video Library

    2011-10-15

    Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary.

  17. Factors associated with attendance to scheduled outpatient endoscopy.

    PubMed

    Laiyemo, Adeyinka O; Williams, Carla D; Burnside, Clinton; Moghadam, Sepideh; Sanasi-Bhola, Kamla D; Kwagyan, John; Brim, Hassan; Ashktorab, Hassan; Scott, Victor F; Smoot, Duane T

    2014-10-01

    Non-attendance of 42% has been reported for outpatient colonoscopy among persons with low socioeconomic status (SES) in an open access system in the USA. To evaluate attendance to outpatient endoscopy among populations with low SES after inperson consultations with endoscopists prior to scheduling. Retrospectively, we reviewed the endoscopy schedule from September 2009 to August 2010 in an inner city teaching hospital in Washington, DC. We identified patients who came for their procedures. We defined non-attendance as when patients did not notify the facility up to 24 h prior to their scheduled procedures and did not show up. A total of 3304 patients were scheduled for outpatient endoscopy (mean age 55.2 years; 59.5% women). Only 36 (1.1%) patients were uninsured. 716 (21.7%) patients did not show up for their procedures. There were no differences in attendance by age, sex and race. Patients seen in a private endoscopist's office (OR=1.47; 95% CI 1.07 to 2.04) were more likely to attend when compared with patients seen in trainees' continuity clinic. Married patients (OR=1.40; 95% CI 1.11 to 1.78) were also more likely to attend. Conversely, Medicaid and uninsured patients were less likely to attend. Restricting our analysis to patients scheduled for only colonoscopy yielded similar results except that patients aged 50 years and older were more likely to attend. Our study suggests improved attendance to endoscopy when populations with lower SES undergo prior consultation with an endoscopist. There is a potential to further improve attendance to outpatient endoscopy by directly involving the social support of the patients. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Correlations between symptoms, nasal endoscopy, and in-office computed tomography in post-surgical chronic rhinosinusitis patients.

    PubMed

    Ryan, William R; Ramachandra, Tara; Hwang, Peter H

    2011-03-01

    To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.

  19. Sedation and Monitoring in the Pediatric Patient during Gastrointestinal Endoscopy.

    PubMed

    Chung, Hyun Kee; Lightdale, Jenifer R

    2016-07-01

    Sedation is a fundamental component of pediatric gastrointestinal procedures. The 2 main types of sedation for pediatric endoscopy remain general anesthesia and procedural sedation. Although anesthesiologist-administered sedation protocols are more common, there is no ideal regimen for endoscopy in children. This article discusses specific levels of sedation for endoscopy as well as various regimens that can be used to achieve each. Risks and considerations that may be specific to performing gastrointestinal procedures in children are reviewed. Finally, potential future directions for sedation and monitoring that may change the practice of pediatric gastroenterology and ultimately patient outcomes are examined. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. 30. LAUNCH CONTROL CAPSULE. ACOUSTICAL ENCLOSURE. OPERATORS' CHAIR AND COMMUNICATIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. LAUNCH CONTROL CAPSULE. ACOUSTICAL ENCLOSURE. OPERATORS' CHAIR AND COMMUNICATIONS CONSOLE IN FOREGROUND. ELECTRONIC EQUIPMENT RACK AT LEFT; LAUNCH CONTROL CONSOLE WITH CAPTAIN JAMES L. KING, JR. IN CENTER. LIEUTENANT KEVIN R. MCCLUNEY IN BACKGROUND. VIEW TO SOUTHEAST. - Minuteman III ICBM Launch Control Facility November-1, 1.5 miles North of New Raymer & State Highway 14, New Raymer, Weld County, CO

  1. Endoscopy and sedation: an inseparable binomial for the gastroenterologist.

    PubMed

    Crespo, Javier; Terán, Álvaro

    2018-04-01

    The development of endoscopy and its increasing demand among the population have led to a growing need for propofol-based sedation techniques. Benefit is indisputable for both patients and endoscopists, but some aspects require considering the "who" and "how" of sedation as related to safety and health care costs. Propofol is first-choice in endoscopy for the European Society of Gastrointestinal Endoscopy because of its fast onset of action and short half-life, and many reports exist on its safety when used by gastroenterologists rather than anesthesiologists. In this issue of REED several originals support the efficiency and safety of propofol even for complex, high-risk, or protracted procedures such as endoscopic retrograde cholangiopancreatography (ERCP) and enteroscopy. Propofol may be safely and effectively administered by a team with specific skills acquired through education and using a specific procedure. However, difficulties arise in real-world clinical practice that preclude such training, which in Spain should be included in the MIR (médico interno residente) specialization program curriculum. The Comisión Nacional de Digestivo (Spanish National Commission on Digestive Diseases), sensitive to this training gap, has included in their latest version of the MIR program (under assessment) four additional competences, with number 145 (training in deep sedation) being most relevant here. In addition, the Spanish Society of Gastrointestinal Endoscopy (SEED) has invested significant efforts in sedation training, with over 50 courses on sedation for endoscopists and nurses. Continuing education and training in this field (for instance, refresher courses on advanced cardiopulmonary resuscitation) should be a goal for all endoscopy units. Because of the diversity found among hospitals, with single or multiple endoscopy rooms, efforts should be made to persuade those in charge of gastroenterology and anesthesiology departments to establish the necessary care

  2. Helicobacter pylori-negative gastric mucosa-associated lymphoid tissue lymphoma: magnifying endoscopy findings.

    PubMed

    Law, T T; Tong, Daniel; Wong, Sam W H; Chan, S Y; Law, Simon

    2015-04-01

    Gastric mucosa-associated lymphoid tissue lymphoma is uncommon and most patients have an indolent clinical course. The clinical presentation and endoscopic findings can be subtle and diagnosis can be missed on white light endoscopy. Magnifying endoscopy may help identify the abnormal microstructural and microvascular patterns, and target biopsies can be performed. We describe herein the case of a 64-year-old woman with Helicobacter pylori-negative gastric mucosa-associated lymphoid tissue lymphoma diagnosed by screening magnification endoscopy. Helicobacter pylori-eradication therapy was given and she received biological therapy. She is in clinical remission after treatment. The use of magnification endoscopy in gastric mucosa-associated lymphoid tissue lymphoma and its management are reviewed.

  3. [The role of endoscopy in gastroenteropancreatic neuroendocrine tumors].

    PubMed

    Magno, L; Sivero, L; Napolitano, V; Ruggiero, S; Fontanarosa, G; Massa, S

    2010-01-01

    Versione italiana Riassunto: Il ruolo dell'endoscopia nei tumori neuroendocrini gastroenteropancreatici. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa I tumori neuroendocrini (NET) gastro-entero-pancreatici (GEP) sono neoplasie rare che originano dalle cellule neuroendocrine del tubo digerente e del pancreas. L'endoscopia digestiva e l'ecoendoscopia rivestono un ruolo importante nella diagnosi, stadiazione e sorveglianza dei pazienti con NET. Inoltre, in casi selezionati, le tecniche endoscopiche operative consentono il trattamento di queste neoplasie in fase precoce. English version Summary: The role of endoscopy in gastroenteropancreatic neuroendocrine tumors. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa Gastroenteropancreatic (GEP) neuroendocrine tumors (NET) are rare neoplasia arisen from neuroendocrine cells present in the gut mucosa and pancreas. Digestive endoscopy and endoscopic ultrasonography play a relevant role in NET diagnosis, stadiation and surveillance. Moreover, in selected patients, surgical endoscopy allows the tratment of these cancers at an early stage.

  4. Sedation and analgesia in gastrointestinal endoscopy: What’s new?

    PubMed Central

    Fanti, Lorella; Testoni, Pier Alberto

    2010-01-01

    Various types of sedation and analgesia technique have been used during gastrointestinal endoscopy procedures. The best methods for analgesia and sedation during gastrointestinal endoscopy are still debated. Providing an adequate regimen of sedation/analgesia might be considered an art, influencing several aspects of endoscopic procedures: the quality of the examination, the patient’s cooperation and the patient’s and physician’s satisfaction with the sedation. The properties of a model sedative agent for endoscopy would include rapid onset and offset of action, analgesic and anxiolytic effects, ease of titration to desired level of sedation, rapid recovery and an excellent safety profile. Therefore there is an impulse for development of new approaches to endoscopic sedation. This article provides an update on the methods of sedation today available and future directions in endoscopic sedation. PMID:20503443

  5. The European Society of Gastrointestinal Endoscopy Quality Improvement Initiative: developing performance measures.

    PubMed

    Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul

    2016-01-01

    The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision.ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers

    PubMed Central

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-01-01

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology. PMID:26361416

  7. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers.

    PubMed

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-09-07

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology.

  8. Fibre-optic nonlinear optical microscopy and endoscopy.

    PubMed

    Fu, L; Gu, M

    2007-06-01

    Nonlinear optical microscopy has been an indispensable laboratory tool of high-resolution imaging in thick tissue and live animals. Rapid developments of fibre-optic components in terms of growing functionality and decreasing size provide enormous opportunities for innovations in nonlinear optical microscopy. Fibre-based nonlinear optical endoscopy is the sole instrumentation to permit the cellular imaging within hollow tissue tracts or solid organs that are inaccessible to a conventional optical microscope. This article reviews the current development of fibre-optic nonlinear optical microscopy and endoscopy, which includes crucial technologies for miniaturized nonlinear optical microscopy and their embodiments of endoscopic systems. A particular attention is given to several classes of photonic crystal fibres that have been applied to nonlinear optical microscopy due to their unique properties for ultrashort pulse delivery and signal collection. Furthermore, fibre-optic nonlinear optical imaging systems can be classified into portable microscopes suitable for imaging behaving animals, rigid endoscopes that allow for deep tissue imaging with minimally invasive manners, and flexible endoscopes enabling imaging of internal organs. Fibre-optic nonlinear optical endoscopy is coming of age and a paradigm shift leading to optical microscope tools for early cancer detection and minimally invasive surgery.

  9. Knowledge of quality performance measures associated with endoscopy among gastroenterology trainees and the impact of a web-based intervention

    PubMed Central

    Thompson, Jennifer S.; Lebwohl, Benjamin; Syngal, Sapna; Kastrinos, Fay

    2013-01-01

    Background Knowledge of quality measures in endoscopy among trainees is unknown. Objective To assess knowledge of endoscopy-related quality indicators among U.S. trainees and determine whether it improves with a Web-based intervention. Design Randomized, controlled study. Setting Multicenter. Participants This study involved trainees identified from the American Society for Gastrointestinal Endoscopy membership database. Intervention Participants were invited to complete an 18-question online test. Respondents were randomized to receive a Web-based tutorial (intervention) or not. The test was readministered 6 weeks after randomization to determine the intervention’s impact. Main Outcome Measurements Baseline knowledge of endoscopy-related quality indicators and impact of the tutorial. Results A total of 347 of 1220 trainees (28%) completed the test; the mean percentage of correct responses was 55%. For screening colonoscopy, 44% knew the adenoma detection rate benchmark, 42% identified the cecal intubation rate goal, and 74% knew the recommended minimum withdrawal time. A total of 208 of 347 trainees (59%) completed the second test; baseline scores were similar for the tutorial (n = 106) and no tutorial (n = 102) groups (56.4% vs 56.9%, respectively). Scores improved after intervention for the tutorial group (65%, P = .003) but remained unchanged in the no tutorial group. On multivariate analysis, each additional year in training (odds ratio [OR] 2.3; 95% confidence interval [CI], 1.5–3.4), training at an academic institution (OR 2.6; 95% CI, 1.1–6.3), and receiving the tutorial (OR 3.2; 95% CI, 1.7–5.9) were associated with scores in the upper tertile. Limitations Low response rate. Conclusion Knowledge of endoscopy-related quality performance measures is low among trainees but can improve with a Web-based tutorial. Gastroenterology training programs may need to incorporate a formal didactic curriculum to supplement practice-based learning of quality

  10. Optimizing efficiency and operations at a California safety-net endoscopy center: a modeling and simulation approach.

    PubMed

    Day, Lukejohn W; Belson, David; Dessouky, Maged; Hawkins, Caitlin; Hogan, Michael

    2014-11-01

    Improvements in endoscopy center efficiency are needed, but scant data are available. To identify opportunities to improve patient throughput while balancing resource use and patient wait times in a safety-net endoscopy center. Safety-net endoscopy center. Outpatients undergoing endoscopy. A time and motion study was performed and a discrete event simulation model constructed to evaluate multiple scenarios aimed at improving endoscopy center efficiency. Procedure volume and patient wait time. Data were collected on 278 patients. Time and motion study revealed that 53.8 procedures were performed per week, with patients spending 2.3 hours at the endoscopy center. By using discrete event simulation modeling, a number of proposed changes to the endoscopy center were assessed. Decreasing scheduled endoscopy appointment times from 60 to 45 minutes led to a 26.4% increase in the number of procedures performed per week, but also increased patient wait time. Increasing the number of endoscopists by 1 each half day resulted in increased procedure volume, but there was a concomitant increase in patient wait time and nurse utilization exceeding capacity. By combining several proposed scenarios together in the simulation model, the greatest improvement in performance metrics was created by moving patient endoscopy appointments from the afternoon to the morning. In this simulation at 45- and 40-minute appointment times, procedure volume increased by 30.5% and 52.0% and patient time spent in the endoscopy center decreased by 17.4% and 13.0%, respectively. The predictions of the simulation model were found to be accurate when compared with actual changes implemented in the endoscopy center. Findings may not be generalizable to non-safety-net endoscopy centers. The combination of minor, cost-effective changes such as reducing appointment times, minimizing and standardizing recovery time, and making small increases in preprocedure ancillary staff maximized endoscopy center

  11. Capsule Escape Tests - Wallops Island

    NASA Image and Video Library

    1959-05-14

    Caption: Off the pad abort shot at Wallops using Langley PARD designed full scale capsule with Recruit rocket and extended skirt main parachute. Shows sequential images of launch and capsule splashdown.

  12. Contraception with subdermal ST-1435 capsules: side-effects, endocrine profiles and liver function related to different lengths of capsules.

    PubMed

    Kurunmäki, H; Toivonen, J; Lähteenmäki, P; Luukkainen, T

    1985-03-01

    One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.

  13. Lasers in digestive endoscopy

    NASA Astrophysics Data System (ADS)

    Brunetaud, Jean Marc; Maunoury, Vincent; Cochelard, Dominique

    1997-01-01

    Lasers were introduced in digestive endoscopy to stop active gastroduodenal hemorrhages. Their use spread progressively to the treatment of chronic hemorrhages from vascular malformations and sessile tumors. Laser face competition from other endoscopic techniques such as electrocoagulation, injection techniques, dilation, stents, and brachytherapy. Many series have reported the efficacy of lasers in digestive endoscopy used for their thermal or photochemical effects. However, they were gradually abandoned for the treatment of hemorrhages because of competition from nonlaser techniques. Lasers are still used for ablation of sessile tumors, but their true impact is difficult to evaluate. Modern methods of technology assessment did not allow gastroenterologists to clearly define the place of lasers among surgery, radio-chemotherapy, and other endoscopic techniques, and data on the daily use of lasers are not available. Therefore, the conclusion can only be subjective. The best current application of thermal lasers appears to be in the treatment of rectosigmoid villous adenomas in elderly patients. Small superficial rectal cancers may also become a good subject due to the impact of endoscopic ultrasonography. Early lesions with multifocal or diffuse disease such as early esophageal cancers could be the most promising subject of application for photodynamic therapy in the future.

  14. Guideline for obtaining valid consent for gastrointestinal endoscopy procedures.

    PubMed

    Everett, Simon M; Griffiths, Helen; Nandasoma, U; Ayres, Katie; Bell, Graham; Cohen, Mike; Thomas-Gibson, Siwan; Thomson, Mike; Naylor, Kevin M T

    2016-10-01

    Much has changed since the last guideline of 2008, both in endoscopy and in the practice of obtaining informed consent, and it is vital that all endoscopists who are responsible for performing invasive and increasingly risky procedures are aware of the requirements for obtaining valid consent. This guideline is restricted to GI endoscopy but we cover elective and acute or emergency procedures. Few clinical trials have been carried out in relation to informed consent but most areas are informed by guidance from the General Medical Counsel (GMC) and/or are enshrined in legislation. Following an iterative voting process a series of recommendations have been drawn up that cover the majority of situations that will be encountered by endoscopists. This is not exhaustive and where doubt exists we have described where legal advice is likely to be required. This document relates to the law and endoscopy practice in the UK-where there is variation between the four devolved countries this is pointed out and endoscopists must be aware of the law where they practice. The recommendations are divided into consent for patients with and without capacity and we provide sections on provision of information and the consent process for patients in a variety of situations. This guideline is intended for use by all practitioners who request or perform GI endoscopy, or are involved in the pathway of such patients. If followed, we hope this document will enhance the experience of patients attending for endoscopy in UK units. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  15. First order capsules comparative arrangements

    NASA Technical Reports Server (NTRS)

    1963-01-01

    Pen and ink views of comparative arragements of several capsules including the existing 'Big Joe' design, the compromise 'Big Joe' design, and the 'Little Joe'. All capsule designs are labeled and include dimensions.

  16. Cerebral gas embolism due to upper gastrointestinal endoscopy.

    PubMed

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E

    2009-07-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of oesophageal cancer. During the procedure, cerebral gas emboli developed resulting in an acute left-sided hemiparesis. After hyperbaric oxygen therapy, the patient recovered almost completely. The aetiology and treatment is discussed based on the reviewed literature. Once cerebral gas emboli are recognized, patient outcome can be improved by hyperbaric oxygen therapy.

  17. [Management of Patients on Antithrombotic Agents Undergoing Endoscopy].

    PubMed

    Kim, Joon Sung; Kim, Byung Wook

    2018-05-25

    Antithrombotic agents are used increasingly in Asia. The management of patients on antithrombotics undergoing elective or emergency endoscopy has become an increasing clinical challenge for gastroenterologists. Current practice guidelines have been developed by societies from western countries. On the other hand, these guidelines cannot meet the specific needs of the Asian Pacific region, raising the need for separate guidelines in Asia. This review compares the recommendations of previous guidelines with the most recently published Asian guidelines regarding the management of patients on antithrombotic agents undergoing elective and emergency endoscopy.

  18. Nanocomposite capsules with directional, pulsed nanoparticle release.

    PubMed

    Udoh, Christiana E; Cabral, João T; Garbin, Valeria

    2017-12-01

    The precise spatiotemporal delivery of nanoparticles from polymeric capsules is required for applications ranging from medicine to materials science. These capsules derive key performance aspects from their overall shape and dimensions, porosity, and internal microstructure. To this effect, microfluidics provide an exceptional platform for emulsification and subsequent capsule formation. However, facile and robust approaches for nanocomposite capsule fabrication, exhibiting triggered nanoparticle release, remain elusive because of the complex coupling of polymer-nanoparticle phase behavior, diffusion, phase inversion, and directional solidification. We investigate a model system of polyelectrolyte sodium poly(styrene sulfonate) and 22-nm colloidal silica and demonstrate a robust capsule morphology diagram, achieving a range of internal morphologies, including nucleated and bicontinuous microstructures, as well as isotropic and non-isotropic external shapes. Upon dissolution in water, we find that capsules formed with either neat polymers or neat nanoparticles dissolve rapidly and isotropically, whereas bicontinuous, hierarchical, composite capsules dissolve via directional pulses of nanoparticle clusters without disrupting the scaffold, with time scales tunable from seconds to hours. The versatility, facile assembly, and response of these nanocomposite capsules thus show great promise in precision delivery.

  19. Deep Learning in Gastrointestinal Endoscopy.

    PubMed

    Patel, Vivek; Armstrong, David; Ganguli, Malika; Roopra, Sandeep; Kantipudi, Neha; Albashir, Siwar; Kamath, Markad V

    2016-01-01

    Gastrointestinal (GI) endoscopy is used to inspect the lumen or interior of the GI tract for several purposes, including, (1) making a clinical diagnosis, in real time, based on the visual appearances; (2) taking targeted tissue samples for subsequent histopathological examination; and (3) in some cases, performing therapeutic interventions targeted at specific lesions. GI endoscopy is therefore predicated on the assumption that the operator-the endoscopist-is able to identify and characterize abnormalities or lesions accurately and reproducibly. However, as in other areas of clinical medicine, such as histopathology and radiology, many studies have documented marked interobserver and intraobserver variability in lesion recognition. Thus, there is a clear need and opportunity for techniques or methodologies that will enhance the quality of lesion recognition and diagnosis and improve the outcomes of GI endoscopy. Deep learning models provide a basis to make better clinical decisions in medical image analysis. Biomedical image segmentation, classification, and registration can be improved with deep learning. Recent evidence suggests that the application of deep learning methods to medical image analysis can contribute significantly to computer-aided diagnosis. Deep learning models are usually considered to be more flexible and provide reliable solutions for image analysis problems compared to conventional computer vision models. The use of fast computers offers the possibility of real-time support that is important for endoscopic diagnosis, which has to be made in real time. Advanced graphics processing units and cloud computing have also favored the use of machine learning, and more particularly, deep learning for patient care. This paper reviews the rapidly evolving literature on the feasibility of applying deep learning algorithms to endoscopic imaging.

  20. Gelatin capsule in stomach (image)

    MedlinePlus

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  1. Thermoregulation of Capsule Production by Streptococcus pyogenes

    PubMed Central

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  2. Opened Proton Pump Inhibitor Capsules Reduce Time to Healing Compared With Intact Capsules for Marginal Ulceration Following Roux-en-Y Gastric Bypass.

    PubMed

    Schulman, Allison R; Chan, Walter W; Devery, Aiofe; Ryan, Michele B; Thompson, Christopher C

    2017-04-01

    Marginal ulceration, or ulceration at the gastrojejunal anastomosis, is a common complication of Roux-en-Y gastric bypass (RYGB). Acidity likely contributes to the pathophysiology, and proton pump inhibitors (PPIs) frequently are prescribed for treatment. However, patients with gastric bypass only have a small gastric pouch and rapid small-bowel transit, which limits the opportunity for capsule breakdown and PPI absorption. Soluble PPIs (open capsules [OCs]) might be absorbed more easily than intact capsules (ICs). We compared time to ulcer healing, number of endoscopic procedures, and use of health care for patients with marginal ulceration who received PPIs in OC vs IC form. We performed a retrospective study of 164 patients diagnosed with marginal ulceration who underwent RYGB at the Brigham and Women's Hospital from 2000 through 2015. Patients received high-dose PPIs and underwent repeat endoscopy every 3 months until ulcer healing was confirmed. We used time-to-event analysis with a Cox proportional hazards model to evaluate the association between mode of PPI administration and time to ulcer healing, in addition to Cox multivariate regression analysis. Total charge (procedural and maintenance) was determined by comparison of categorized charges incurred from time of ulcer diagnosis to resolution. The primary outcome was time to healing of marginal ulceration in RYGB patients receiving high-dose PPIs in OC vs IC form. A total of 162 patients were included (115 received OC and 49 received IC). All patients were followed up until ulcer healing was confirmed. The median time to ulcer healing was 91.0 days for the OC group vs 342.0 days for the IC group (P < .001). OC was the only independent predictor of time to ulcer healing (P < .001) when we controlled for known risk factors. The number of endoscopic procedures (P = .02) and overall health care utilization (P = .05) were lower in the OC than the IC group. Patients with marginal ulceration after RYGB who

  3. Delayed bleeding and hemorrhage of mucosal defects after gastric endoscopic submucosal dissection on second-look endoscopy.

    PubMed

    Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya

    2016-04-01

    Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p < 0.05). Complication of a histological ulcer, large size of the resected specimen and long ESD procedure time were shown to be risk factors for hemorrhage of mucosal defects after ESD on second-look endoscopy by univariate analysis. Multivariate analysis indicated that only large size of the resected specimen was a risk factor. In a specimen size of >35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.

  4. Big Joe Capsule Assembly Activities

    NASA Image and Video Library

    1959-08-01

    Big Joe Capsule Assembly Activities in 1959 at NASA Glenn Research Center (formerly NASA Lewis). Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959.

  5. The effects of hematoma on implant capsules.

    PubMed

    Caffee, H H

    1986-02-01

    Hematoma surrounding an implant is one of the many factors that have been suggested as possible causes for scar capsule contracture. In this study, experiments were designed to determine the influence of hematoma on the incidence and severity of capsule contracture in rabbits. Two implants were placed in each animal, 1 with a surrounding hematoma and 1 control. Capsules were evaluated subjectively and compared objectively with measurements of deformability, surface area, and capsule thickness. No differences were found with any of the objective criteria, which suggests that hematoma may not be a noteworthy cause of implant capsule contracture.

  6. Stennis time capsule

    NASA Image and Video Library

    2011-10-15

    Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary. NASA publicly announced plans to build the rocket engine test site Oct. 25, 1961.

  7. Management of Suspicious Mucosa-Associated Lymphoid Tissue Lymphoma in Gastric Biopsy Specimens Obtained during Screening Endoscopy.

    PubMed

    Yang, Hyo-Joon; Lim, Seon Hee; Lee, Changhyun; Choi, Ji Min; Yang, Jong In; Chung, Su Jin; Choi, Seung Ho; Im, Jong Pil; Kim, Sang Gyun; Kim, Joo Sung

    2016-07-01

    It is often difficult to differentiate gastric mucosa-associated lymphoid tissue (MALT) lymphoma from Helicobacter pylori-associated follicular gastritis, and thus, it becomes unclear how to manage these diseases. This study aimed to explore the management strategy for and the long-term outcomes of suspicious gastric MALT lymphoma detected by forceps biopsy during screening upper endoscopy. Between October 2003 and May 2013, consecutive subjects who were diagnosed with suspicious gastric MALT lymphomas by screening endoscopy in a health checkup program in Korea were retrospectively enrolled. Suspicious MALT lymphoma was defined as a Wotherspoon score of 3 or 4 upon pathological evaluation of the biopsy specimen. Of 105,164 subjects who underwent screening endoscopies, 49 patients with suspicious MALT lymphomas who underwent subsequent endoscopy were enrolled. Eight patients received a subsequent endoscopy without H. pylori eradication (subsequent endoscopy only group), and 41 patients received H. pylori eradication first followed by endoscopy (eradication first group). MALT lymphoma development was significantly lower in the eradication first group (2/41, 4.9%) than in the subsequent endoscopy only group (3/8, 37.5%, P = 0.026). Notably, among 35 patients with successful H. pylori eradication, there was only one MALT lymphoma patient (2.9%) in whom complete remission was achieved, and there was no recurrence during a median 45 months of endoscopic follow-up. H. pylori eradication with subsequent endoscopy would be a practical management option for suspicious MALT lymphoma detected in a forceps biopsy specimen obtained during screening upper endoscopy.

  8. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  9. [Value of narrow band imaging endoscopy in detection of early laryngeal squamous cell carcinoma].

    PubMed

    Staníková, L; Kučová, H; Walderová, R; Zeleník, K; Šatanková, J; Komínek, P

    2015-01-01

    Narrow band imaging (NBI) is an endoscopic method using filtered wavelengths in detection of microvascular abnormalities associated with preneoplastic and neoplastic changes of the mucosa. The aim of the study is to evaluate the value of NBI endoscopy in the dia-gnosis of laryngeal precancerous and early stages of cancerous lesions and to investigate impact of NBI method in prehistological diagnostics in vivo. One hundred patients were enrolled in the study and their larynx was investigated using white light HD endoscopy and narrow band imaging between 6/ 2013- 10/ 2014. Indication criteria included chronic laryngitis, hoarseness for more than three weeks or macroscopic laryngeal lesion. Features of mucosal lesions were evaluated by white light endoscopy and afterwards were compared with intra-epithelial papillary capillary loop changes, viewed using NBI endoscopy. Suspicious lesions (leukoplakia, exophytic tumors, recurrent respiratory papillomatosis and/ or malignant type of vascular network by NBI endoscopy) were evaluated by histological analysis, results were compared with prehistological NBI dia-gnosis. Using NBI endoscopy, larger demarcation of pathological mucosal features than in white light visualization were recorded in 32/ 100 (32.0%) lesions, in 4/ 100 (4.0%) cases even new lesions were detected only by NBI endoscopy. 63/ 100 (63.0%) suspected lesions were evaluated histologically -  malign changes (carcinoma in situ or invasive carcinoma) were observed in 25/ 63 (39.7%). Prehistological diagnostics of malignant lesions using NBI endoscopy were in agreement with results of histological examination in 23/ 25 (92.0%) cases. The sensitivity of NBI in detecting malignant lesions was 89.3%, specificity of this method was 94.9%. NBI endoscopy is a promising optical technique enabling in vivo differentiation of superficial neoplastic lesions. These results suggest endoscopic NBI may be useful in the early detection of laryngeal cancer and precancerous

  10. Basic ammonothermal GaN growth in molybdenum capsules

    NASA Astrophysics Data System (ADS)

    Pimputkar, S.; Speck, J. S.; Nakamura, S.

    2016-12-01

    Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).

  11. Comparing diagnostic yield of a novel pan-enteric video capsule endoscope with ileocolonoscopy in patients with active Crohn's disease: a feasibility study.

    PubMed

    Leighton, Jonathan A; Helper, Debra J; Gralnek, Ian M; Dotan, Iris; Fernandez-Urien, Ignacio; Lahat, Adi; Malik, Pramod; Mullin, Gerard E; Rosa, Bruno

    2017-01-01

    Crohn's disease (CD) is typically diagnosed with ileocolonoscopy (IC); however, when inflammation is localized solely in the small bowel, visualization of the entire small-bowel mucosa can be challenging. The aim of this study was to compare the diagnostic yield of a pan-enteric video capsule endoscope (small-bowel colon [SBC] capsule) versus IC in patients with active CD. This was a prospective, multicenter study. Patients with known active CD and proven bowel luminal patency underwent a standardized colon cleansing protocol followed by ingestion of the capsule. After passage of the capsule, IC was performed and recorded. Lesions indicative of active CD were assessed. One hundred fourteen subjects were screened; 66 subjects completed both endoscopic procedures. The per-subject diagnostic yield rate for active CD lesions was 83.3% for SBC and 69.7% for IC (yield difference, 13.6%; 95% confidence interval [CI], 2.6%-24.7%); 65% of subjects had active CD lesions identified by both modalities. Of the 12 subjects who were positive for active CD by SBC only, 5 subjects were found to have active CD lesions in the terminal ileum. Three subjects were positive for active CD by IC only. Three hundred fifty-five classifying bowel segments were analyzed; the per-segment diagnostic yield rate was 40.6% for SBC and 32.7% for IC (yield difference 7.9%; 95% CI, 3.3%-12.4%). This preliminary study shows that the diagnostic yields for SBC might be higher than IC; however, the magnitude of difference between the two is difficult to estimate. Further study is needed to confirm these findings. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Abdominal compression during endoscopy (the Bolster technique) demonstrates hidden Schatzki rings (with videos).

    PubMed

    Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises

    2016-05-01

    Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  13. Quantitative ENT endoscopy: the future in the new millennium

    NASA Astrophysics Data System (ADS)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  14. Injury to endoscopic personnel from tripping over exposed cords, wires, and tubing in the endoscopy suite: a preventable cause of potentially severe workplace injury.

    PubMed

    Cappell, Mitchell S

    2010-04-01

    BACKGROUND The endoscopy unit before remediation may be a high-risk area for slip and fall injuries due to a large number of exposed above-the-floor wires in the endoscopy rooms, dimmed lighting during endoscopic procedures, and staff inattention to obstacles due to preoccupation with the endoscopic patient. AIM To describe a novel, previously unappreciated workplace hazard to endoscopic personnel: Exposed wires in the endoscopy unit.METHODS This study is a retrospective review of 110,000 endoscopic procedures performed during the last 5 years at an academic, teaching hospital with a high-volume endoscopy unit. All significant orthopedic injuries to endoscopic personnel from slips, twists, and falls from tripping over exposed cords in the endoscopy unit were reviewed. The severity of injury was documented based on roentgenographic findings, number of days of missed work, number of days with a modified work schedule, and requirement for orthopedic surgery. The number of potentially exposed cords per endoscopy room was determined. RESULTS During the 5-year study period, three endoscopic personnel suffered significant orthopedic injuries from slips, twists, and falls from tripping over cords, wires, or tubing lying exposed over the floor in the endoscopy suite: The resulting injuries consisted of fourth and fifth metacarpal hand fractures due to a fall after tripping on oxygen tubing; a rib fracture due to tripping on electrical wires trailing from an endoscopy cart; and a grade II ankle sprain due to the foot becoming entangled in oxygen tubing. All injuries resulted in lost days of work [mean 9.3 +/- 11.0 (SD) days] and in additional days of restricted work (mean 41.7 +/- 31.8 days). One injury required orthopedic surgery. Hospital review revealed a mean of 35.3 +/- 7.5 cords, wires, or tubing per endoscopy procedure room, the majority of which were exposed above the floor before remediation (n = 10 rooms). Remediation of exposed wires included: bundling related

  15. Anterior capsule relaxing incisions with neodymium:YAG laser for patients at high-risk for anterior capsule contraction.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hirata, Akira; Hayashi, Hideyuki

    2011-01-01

    To examine the effect of anterior capsule relaxing incisions created with a neodymium:YAG (Nd:YAG) laser on prevention of anterior capsule contraction after cataract surgery in high-risk patients. Hayashi Eye Hospital, Fukuoka, Japan. Randomized masked clinical trials. Patients at high risk for anterior capsule contraction had anterior capsule relaxing incisions in either eye 3 days postoperatively. The anterior capsule opening was measured using a Scheimpflug videophotography system (EAS-1000) immediately and 1, 3, and 6 months after capsulotomy, and the percentage reduction in area was calculated. The degree of intraocular lens (IOL) decentration and tilt, posterior capsule opacification (PCO), and other complications were also assessed. Of the 84 patients included, 30 had primary angle closure, 28 had pseudoexfoliation, and 26 had diabetic retinopathy. There was no significant difference in the mean opening area between fellow eyes at baseline. In patients with primary angle closure, the area was significantly greater and the percentage reduction in area was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0428). In patients with pseudoexfoliation or diabetic retinopathy, the percentage reduction was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0493), although there was no significant difference in area. No significant difference was found in IOL decentration or tilt, PCO, or incidence of other complications. Neodymium:YAG laser anterior capsule relaxing incisions in the early period after cataract surgery were effective in preventing anterior capsule contraction in high-risk patients and had no adverse effects. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Reinforcing effects of caffeine in coffee and capsules.

    PubMed

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  17. Reinforcing effects of caffeine in coffee and capsules.

    PubMed Central

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-01-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839

  18. Sensor capsule for diagnosis of gastric disorders

    NASA Technical Reports Server (NTRS)

    Holen, J. T.

    1972-01-01

    Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

  19. Structure and Composition of the Bacillus anthracis Capsule

    PubMed Central

    Avakyan, A. A.; Katz, L. N.; Levina, K. N.; Pavlova, I. B.

    1965-01-01

    Avakyan, A. A. (Academy of Medical Sciences, Moscow, USSR), L. N. Katz, K. N. Levina, and I. B. Pavlova. Structure and composition of the Bacillus anthracis capsule. J. Bacteriol. 90:1082–1095. 1965.—Observations by various methods of light microscopy (phase contrast, dark-field, and fluorescence) revealed the complex structure of the Bacillus anthracis capsule, which changes regularly during the growth cycle of the culture. Special cytological methods of staining the capsule made it possible to study its fine structure, which is not revealed by negative staining with India ink. For example, the capsule shows a membranelike outline, fine transverse lines, and interruptions and transverse septa traversing the entire capsule. By using cytochemical methods, it was found that the capsule has a stratified structure and that the various layers of the capsule differ as to the value of the isoelectric point, metachromatic ability, sensitivity to various enzymes, and, consequently, chemical composition. It was thus shown that the membranelike outline of the capsule consists of peptides and neutral mucopolysaccharides. The middle part of the capsule consists of a complex of substances of both polysaccharide and protein nature, and the inner part consists of acid mucopolysaccharides. Observation of the capsular forms of B. anthracis by means of an electron microscope revealed differences in the osmiophilia and submicroscopic structure of the membranelike outline and the middle and inner parts of the capsule. Immunochemical studies conducted by the fluorescent-antibody method revealed localization of antigens in different parts of the capsule, and made it possible to differentiate the capsular antigens according to their serum-staining ability and according of their relations to enzymes, i.e., their chemical composition. This paper concerns the possibility of studying the fine structure of bacterial capsules in fixed preparations, and the differences and similarities of

  20. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    PubMed

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy

  1. Prior esophagogastroduodenoscopy does not affect the cecal intubation time at bidirectional endoscopies

    PubMed Central

    Öner, Osman Zekai; Demirci, Rojbin Karakoyun; Gündüz, Umut Rıza; Aslaner, Arif; Koç, Ümit; Bülbüller, Nurullah

    2013-01-01

    Bidirectional endoscopy (BE) is often used to assess patients for the reason of anemia or to screen asymptomatic population for malignancy. Limited clinical data favors to perform first the upper gastrointestinal system endoscopy, but its effect to the duration of colonoscopy is yet to be determined. The aim of this retrospective study is to evaluate the effect of upper gastrointestinal system endoscopy on the time to achieve cecal intubation during colonoscopy in patients undergoing BE. Patients of four endoscopists at similar experience levels were retrospectively identified and categorized into the upper gastrointestinal system endoscopy before colonoscopy group (group 1) or the colonoscopy only group (group 2). The demographics, clinical data and the time to achieve cecal intubation for each patient were analyzed. The mean time to achieve cecal intubation in the first group that included 319 cases was 8.4 ± 0.93 minutes and the mean time in the second group that included 1672 cases was 8.56 ± 1.16 minutes. There was no statistically significant difference between the groups. There was also no significant difference between the Group 1 and Group 2 when compared according to which of the four endoscopists performed the procedures. Performing the upper gastrointestinal system endoscopy prior to colonoscopy did not affect the time to achieve cecal intubation. Considering that performing the upper gastrointestinal system endoscopy prior to the colonoscopy is more advantageous in terms of patient comfort and analgesic requirement, beginning to BE with it seems more favorable. PMID:23936601

  2. Oxygen fugacity and piston cylinder capsule assemblies

    NASA Astrophysics Data System (ADS)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  3. Role of Clinical Endoscopy in Emphasizing Endoscope Disinfection

    PubMed Central

    Ryu, Ji Kon; Kim, Eun Young; Kwon, Kwang An; Choi, Il Ju

    2015-01-01

    Based on the unexpected Middle East respiratory syndrome (MERS) outbreak in Korea, it was established that the virus can spread easily, MERS exposure in hospitals carries an extreme risk for infection as well as mortality, and the sharing of information was essential for infection control. Although the incidence of exogenous infections related to contaminated endoscopes is very low, the majority of published outbreaks have been caused by various shortcomings in reprocessing procedures, including insufficient training or awareness. Ever since the inauguration of "Clinical Endoscopy" as an English-language journal of the Korean Society of Gastrointestinal Endoscopy in 2011, it has published several articles on disinfection of the endoscope and its accessories. Many Science Citation Index journals have also emphasized high-level disinfection of the gastrointestinal endoscope. Many papers have been produced specifically, since the outbreak of carbapenem-resistant Enterobacteriaceae in 2013. The recent review papers concluded that quality control is the most important issue among all the aspects of procedural care, including the efficiency of the gastrointestinal endoscopy unit and reprocessing room. Thorough reprocessing of endoscopes using high-level disinfection and sterilization methods may be essential for reducing the risk of infection. PMID:26473114

  4. The role of a nurse telephone call to prevent no-shows in endoscopy.

    PubMed

    Childers, Ryan E; Laird, Amy; Newman, Lisa; Keyashian, Kian

    2016-12-01

    Preventing missed appointments, or "no-shows," is an important target in improving efficient patient care and lowering costs in gastrointestinal endoscopy practices. We aimed to investigate whether a nurse telephone call would reduce no-show rates for endoscopic appointments, and to determine if hiring and maintaining a nurse dedicated to pre-endoscopy phone calls is economically advantageous. Our secondary aim was to identify predictors of no-shows to endoscopy appointments. We hired and trained a full-time licensed nurse to make a telephone call to patients 7 days before their scheduled upper endoscopy or colonoscopy. We compared this intervention with a previous reminder system involving mailed reminders. The effect of the intervention and impact of other predictors of no-shows were analyzed in 2 similar preintervention and postintervention patient cohorts. A mixed effects logistic regression model was used to estimate the association of the odds of being a no-show to the scheduled appointment and the characteristics of the patient and visit. An analysis of costs was performed that included the startup and maintenance costs of the intervention. We found that a nurse phone call was associated with a 33% reduction in the odds of a no-show visit (odds ratio, 0.67; 95% confidence interval, 0.50-0.91), adjusting for gender, age, partnered status, insurer type, distance from the endoscopy center, and visit type. The recovered reimbursement during the study period was $48,765, with net savings of $16,190 when accounting for the maintenance costs of the intervention; this resulted in a net revenue per annum of $43,173. We found that endoscopy practices may increase revenue, improve scheduling efficiency, and maximize resource utilization by hiring a nurse to reduce no-shows. Predictors of no-shows to endoscopy included unpartnered or single patients, commercial or managed care, being scheduled for colonoscopy as opposed to upper endoscopy, and being scheduled for a

  5. [Endoscopy-assisted sialolithectomy for the calculus of the Stensen's duct].

    PubMed

    Ye, Xin; Xie, Xiaoyan; Liu, Denggao; Zhang, Lei; Zhang, Zuyan; Yu, Guangyan

    2014-11-01

    To investigate the clinical effects of endoscopy-assisted sialolithectomy for the calculus in the Stensen's duct. From August 2005 to July 2013, 67 consecutive patients with calculus (or foreign bodies) in the Stensen's duct underwent explorative and interventional endoscopy in our hospital. The stones (or foreign bodies) were removed by endoscopy-assisted technique. After operation, the patients were followed-up periodically, and treatment effects were analyzed. Among the 67 patients, the stones (or foreign bodies) were completely removed in 58 cases, and almost completely removed in 3 cases, with a success rate of 87% (58/67). Among the 61 stone-removed cases, treatment options included direct removal with aid of basket or forceps (24 cases), basket entrapment and opening-up of the ostium (21 cases), basket entrapment and mucosal incision near the ostium (8 cases), open removal via buccal incision (2 cases) and open removal via pre-auricular flap (6 cases). During the 6-90 months' follow-up of the 61 cases, 48 cases were asymptomatic, 7 had mild symptoms, 3 developed ductal obturation, 1 had numbness in the parotid region, and the remaining 2 were missed. Endoscopy-assisted sialolithectomy is a safe and effective gland-preservation technique for the patients with parotid gland calculus.

  6. Review on sedation for gastrointestinal tract endoscopy in children by non-anesthesiologists

    PubMed Central

    Orel, Rok; Brecelj, Jernej; Dias, Jorge Amil; Romano, Claudio; Barros, Fernanda; Thomson, Mike; Vandenplas, Yvan

    2015-01-01

    AIM: To present evidence and formulate recommendations for sedation in pediatric gastrointestinal (GI) endoscopy by non-anesthesiologists. METHODS: The databases MEDLINE, Cochrane and EMBASE were searched for the following keywords “endoscopy, GI”, “endoscopy, digestive system” AND “sedation”, “conscious sedation”, “moderate sedation”, “deep sedation” and “hypnotics and sedatives” for publications in English restricted to the pediatric age. We searched additional information published between January 2011 and January 2014. Searches for (upper) GI endoscopy sedation in pediatrics and sedation guidelines by non-anesthesiologists for the adult population were performed. RESULTS: From the available studies three sedation protocols are highlighted. Propofol, which seems to offer the best balance between efficacy and safety is rarely used by non-anesthesiologists mainly because of legal restrictions. Ketamine and a combination of a benzodiazepine and an opioid are more frequently used. Data regarding other sedatives, anesthetics and adjuvant medications used for pediatric GI endoscopy are also presented. CONCLUSION: General anesthesia by a multidisciplinary team led by an anesthesiologist is preferred. The creation of sedation teams led by non-anesthesiologists and a careful selection of anesthetic drugs may offer an alternative, but should be in line with national legislation and institutional regulations. PMID:26240691

  7. Job Stress and Job Satisfaction among Health-Care Workers of Endoscopy Units in Korea.

    PubMed

    Nam, Seung-Joo; Chun, Hoon Jai; Moon, Jeong Seop; Park, Sung Chul; Hwang, Young-Jae; Yoo, In Kyung; Lee, Jae Min; Kim, Seung Han; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-05-01

    The management of job-related stress among health-care workers is critical for the improvement of healthcare services; however, there is no existing research on endoscopy unit workers as a team. Korea has a unique health-care system for endoscopy unit workers. In this study, we aimed to estimate job stress and job satisfaction among health-care providers in endoscopy units in Korea. We performed a cross-sectional survey of health-care providers in the endoscopy units of three university-affiliated hospitals in Korea. We analyzed the job stress levels by using the Korean occupational stress scale, contributing factors, and job satisfaction. Fifty-nine workers completed the self-administered questionnaires. The job stress scores for the endoscopy unit workers (46.39±7.81) were relatively lower compared to those of the national sample of Korean workers (51.23±8.83). Job stress differed across job positions, with nurses showing significantly higher levels of stress (48.92±7.97) compared to doctors (42.59±6.37). Job stress and job satisfaction were negatively correlated with each other (R (2) =0.340, p<0.001). An endoscopy unit is composed of a heterogeneous group of health-care professionals (i.e., nurses, fellows, and professors), and job stress and job satisfaction significantly differ according to job positions. Job demand, insufficient job control, and job insecurity are the most important stressors in the endoscopy unit.

  8. Usefulness of positron emission tomography in primary intestinal follicular lymphoma

    PubMed Central

    Tari, Akira; Asaoku, Hideki; Kunihiro, Masaki; Tanaka, Shinji; Yoshino, Tadashi

    2013-01-01

    Double-balloon enteroscopy (DBE) and video capsule endoscopy are useful for the diagnosis of lymphoma in the small intestine. However, DBE cannot be safely performed in cases with passage disturbance due to wall thickening and stenosis. Additionally, video capsule endoscopy cannot be performed in such cases because of the risk of retention. Here, we report 4 cases of primary follicular lymphoma of the gastrointestinal tract that could be detected using 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (PET-CT). The endoscopic findings of these 4 cases included lesions with wall thickening, which comprised macroscopically clusters of nodules, dense clusters of whitish granules or small nodules, fold thickening and ulcers with irregular margins that occupied the whole lumen with edematous mucosa. All patients fulfilled the World Health Organization grade 1 criteria. 18F-fluorodeoxyglucose PET-CT can help predict the risks that may result from certain endoscopic examinations, such as DBE and video capsule endoscopy. PMID:23569346

  9. Vortex rings from Sphagnum moss capsules

    NASA Astrophysics Data System (ADS)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  10. Polyelectrolyte multilayer capsules as vehicles with tunable permeability.

    PubMed

    Antipov, Alexei A; Sukhorukov, Gleb B

    2004-11-29

    This review is devoted to a novel type of polymer micro- and nanocapsules. The shell of the capsule is fabricated by alternate adsorption of oppositely charged polyelectrolytes (PEs) onto the surface of colloidal particles. Cores of different nature (organic or inorganic) with size varied from 0.1 to 10 mum can be used for templating such PE capsules. The shell thickness can be tuned in nanometer range by assembling of defined number of PE layers. The permeability of capsules depends on the pH, ionic strength, solvent, polymer composition, and shell thickness; it can be controlled and varied over wide range of substances regarding their molecular weight and charge. Including functional polymers into capsule wall, such as weak PEs or thermosensitive polymers, makes the capsule permeability sensitive to correspondent external stimuli. Permeability of the capsules is of essential interest in diverse areas related to exploitation of systems with controlled and sustained release properties. The envisaged applications of such capsules/vesicles cover biotechnology, medicine, catalysis, food industry, etc.

  11. Cell cycle constraints on capsulation and bacteriophage susceptibility.

    PubMed

    Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H

    2014-11-25

    Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity.

  12. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  13. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  14. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  15. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  16. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with mercury...

  17. Biomimetic/Bioinspired Design of Enzyme@capsule Nano/Microsystems.

    PubMed

    Shi, J; Jiang, Y; Zhang, S; Yang, D; Jiang, Z

    2016-01-01

    Enzyme@capsule nano/microsystems, which refer to the enzyme-immobilized capsules, have received tremendous interest owing to the combination of the high catalytic activities of encapsulated enzymes and the hierarchical structure of the capsule. The preparation of capsules and simultaneous encapsulation of enzymes is recognized as the core process for the rational design and construction of enzyme@capsule nano/microsystems. The strategy used has three major steps: (a) generation of the templates, (b) surface coating on the templates, and (c) removal of the templates, and it has been proven to be effective and versatile for the construction of enzyme@capsule nano/microsystems. Several conventional methods, including layer-by-layer assembly of polyelectrolytes, liquid crystalline templating method, etc., were used to design and construct enzyme@capsule nano/microsystems, but these have two major drawbacks. One is the low mechanical stability of the systems and the second is the harsh conditions used in the construction process. Learning from nature, several biomimetic/bioinspired methods such as biomineralization, biomimetic/bioinspired adhesion, and their combination have been exploited for the construction of enzyme@capsule nano/microsystems. In this chapter, we will present a general protocol for the construction of enzyme@capsule nano/microsystems using the latter approach. Some suggestions for improved design, construction, and characterization will also be presented with detailed procedures for specific examples. © 2016 Elsevier Inc. All rights reserved.

  18. "Endoview" project of intrapartum endoscopy.

    PubMed

    Petrikovsky, Boris M; Ravens, Steven

    2002-01-01

    The change in obstetrical practices over the last decade in favor of trials of labor in patients with uterine scars has resulted in increased incidences of uterine ruptures. Although neither repeat cesarean delivery nor a trial of labor is risk free, evidence from a large multicenter study shows vaginal birth after the cesarean (VBAC) is associated with shorter hospital stays, fewer postpartum blood transfusions, and a decreased incidence of postpartum maternal fever. The uterine rupture remains the most serious complication associated with VBAC. Factors associated with uterine rupture include excessive exposure to oxytocin, dysfunctional labor, and a history of more than 1 cesarean delivery.2 Because uterine rupture may be a life-threatening event, intrapartum surveillance and the ability to perform an emergency surgery are both necessary when trial of labor is allowed. Until now, no early symptoms pathognomonic to uterine rupture had been described. We share our experiences with the novel approach to the problem - an intrapartum endoscopy. Endoscopic examination was accomplished by using the intraoperational fiberscope (Olympus and Endoview system (Costa Mesa, CA, USA). A gas-sterilized 25-cm long fiberscope is introduced into the amniotic cavity through the cervical canal after rupture of the membranes. The distance between the fiberscope and the object varies from 3 to 50 mm. The fiberscope has a separate channel for the fluid infusion (normal saline) throughout the procedure; the surgeon looks through the eyepiece directly and exhibits control over the flexible scope. The duration of endoscopy is less than 15 minutes. The inserting of the endoscopic device is very similar to that of insertion of an intrauterine pressure catheter. The IRB Committees of both participating institutions approved the study protocol. Twenty-eight patients with an unknown or poorly documented site of the uterine scar were included in the study. An ultrasound examination had been

  19. Patient satisfaction with the endoscopy experience and willingness to return in a central Canadian health region.

    PubMed

    Loftus, Russell; Nugent, Zoann; Graff, Lesley A; Schumacher, Frederick; Bernstein, Charles N; Singh, Harminder

    2013-01-01

    Patient experiences with endoscopy visits within a large central Canadian health region were evaluated to determine the relationship between the visit experience and the patients' willingness to return for future endoscopy, and to identify the factors associated with patients' willingness to return. A self-report survey was distributed to 1200 consecutive individuals undergoing an upper and⁄or lower gastrointestinal endoscopy at any one of the six hospital-based endoscopy facilities in the region. The Spearman correlation coefficient was used to assess the association between the patients' overall rating of the visits and willingness to return for repeat procedures under similar medical circumstances. Logistic regression analyses were performed to identify the factors associated with willingness to return for repeat endoscopy and overall satisfaction (rating) of the visit. A total of 529 (44%) individuals returned the questionnaire, with 45% rating the visit as excellent and 56% indicating they were extremely likely to return for repeat endoscopy. There was a low moderate correlation between overall rating of the visit and patients' willingness to return for repeat endoscopy (r=0.30). The factors independently associated with patient willingness to return for repeat endoscopy included perceived technical skills of the endoscopists (OR 2.7 [95% CI 1.3 to 5.5]), absence of pain during the procedure (OR 2.2 [95% CI 1.3 to 3.6]) and history of previous endoscopy (OR 2.4 [95% CI 1.4 to 4.1]). In contrast, the independent factors associated with the overall rating of the visit included information provided pre- and postprocedure, wait time before and on the day of the visit, and the physical environment. To facilitate patient return for needed endoscopy, it is important to assess patients' willingness to return because positive behavioural intent is not simply a function of satisfaction with the visit.

  20. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    PubMed

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  1. Differences in clinical characteristics between patients with endoscopy-negative reflux disease and erosive esophagitis in Japan.

    PubMed

    Fujiwara, Yasuhiro; Higuchi, Kazuhide; Shiba, Masatsugu; Yamamori, Kazuki; Watanabe, Yoko; Sasaki, Eiji; Tominaga, Kazunari; Watanabe, Toshio; Oshitani, Nobuhide; Arakawa, Tetsuo

    2005-04-01

    Helicobacter pylori infection and atrophic gastritis are inversely related to erosive esophagitis. Whether these factors affect the pathogenesis of endoscopy-negative reflux disease is not clear. We aimed to elucidate the differences in clinical characteristics between endoscopy-negative erosive disease and erosive esophagitis. 253 subjects (89 with endoscopy-negative reflux disease and 164 with erosive esophagitis) were studied. Gastric atrophy was assessed by measurement of serum pepsinogen. Logistic regression was used to calculate the odds ratio (OR) and 95% confidence intervals (CI) of endoscopy-negative reflux disease compared with erosive esophagitis. Among GERD patients, female gender (OR = 2.27, 95% CI, 1.25-4.10), smoking (OR = 0.45, 95% CI, 0.22-0.91), and the presence of hiatal hernia (OR = 0.30, 95% CI, 0.17-0.56) were significantly associated with endoscopy-negative reflux disease compared with male gender, not smoking, and absence of hiatal hernia, respectively. Body mass index (BMI) was also significantly associated with a decreased OR for endoscopy-negative reflux disease. Although H. pylori infection and gastric atrophy were significantly more common in patients with endoscopy-negative reflux disease, these associations did not persist in a multiple-adjustment model. After adjustment for gender, BMI, smoking, and hiatal hernia, a decrease in serum pepsinogen I/II ratio was significantly associated with an increased OR for endoscopy-negative reflux disease (p for trend = 0.018). Female gender, low BMI, not smoking, absence of hiatal hernia, and severity of gastric atrophy were positively associated with endoscopy-negative reflux disease compared with erosive esophagitis among Japanese patients.

  2. 3D Printed Programmable Release Capsules.

    PubMed

    Gupta, Maneesh K; Meng, Fanben; Johnson, Blake N; Kong, Yong Lin; Tian, Limei; Yeh, Yao-Wen; Masters, Nina; Singamaneni, Srikanth; McAlpine, Michael C

    2015-08-12

    The development of methods for achieving precise spatiotemporal control over chemical and biomolecular gradients could enable significant advances in areas such as synthetic tissue engineering, biotic-abiotic interfaces, and bionanotechnology. Living organisms guide tissue development through highly orchestrated gradients of biomolecules that direct cell growth, migration, and differentiation. While numerous methods have been developed to manipulate and implement biomolecular gradients, integrating gradients into multiplexed, three-dimensional (3D) matrices remains a critical challenge. Here we present a method to 3D print stimuli-responsive core/shell capsules for programmable release of multiplexed gradients within hydrogel matrices. These capsules are composed of an aqueous core, which can be formulated to maintain the activity of payload biomolecules, and a poly(lactic-co-glycolic) acid (PLGA, an FDA approved polymer) shell. Importantly, the shell can be loaded with plasmonic gold nanorods (AuNRs), which permits selective rupturing of the capsule when irradiated with a laser wavelength specifically determined by the lengths of the nanorods. This precise control over space, time, and selectivity allows for the ability to pattern 2D and 3D multiplexed arrays of enzyme-loaded capsules along with tunable laser-triggered rupture and release of active enzymes into a hydrogel ambient. The advantages of this 3D printing-based method include (1) highly monodisperse capsules, (2) efficient encapsulation of biomolecular payloads, (3) precise spatial patterning of capsule arrays, (4) "on the fly" programmable reconfiguration of gradients, and (5) versatility for incorporation in hierarchical architectures. Indeed, 3D printing of programmable release capsules may represent a powerful new tool to enable spatiotemporal control over biomolecular gradients.

  3. Characteristics of patients with a retained wireless capsule endoscope (WCE) necessitating laparotomy for removal of the capsule.

    PubMed

    Purdy, Martin; Heikkinen, Markku; Juvonen, Petri; Voutilainen, Markku; Eskelinen, Matti

    2011-01-01

    A capsule endoscope is a wireless miniature camera used to take images of the small bowel mucosa. Retention of the wireless capsule endoscope (WCE), defined as at least two weeks' retention or an obstruction demanding removal by laparotomy, is the main and practically only complication of the procedure. The aim of this study was to evaluate the characteristics of patients with a retained WCE necessitating laparotomy for removal of the capsule or capsule fragments. The medical records of 555 patients who had undergone the WCE procedure over a 7-year period (2002-2008) were reviewed. The indications for the WCE procedure were, obscure gastrointestinal bleeding, Crohn's disease, abdominal pain and suspicion of malignancy. A retained WCE requiring operative treatment was found in 10 cases (in nine patients, twice in one patient). The WCE retention frequency of 1.8% (10/555) equalled that in the literature. The retention rate of WCE capsules is low and routine examination of the small bowel with MRI or CT is not necessary before WCE. These examinations were enable to predict WCE retention according to our results.

  4. Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.

    PubMed

    Loffeld, R J L F; Liberov, B; Dekkers, P E P

    2015-07-01

    The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p < 0.001), these two had the longest careers in endoscopy. The two younger endoscopists did significantly less often procedures in patients with anastomoses and because of surveillance (p < 0.001, respectively). One endoscopist detected significantly less colorectal cancers than the other three endoscopists (p < 0.001). This study presents the PDR in normal routine daily endoscopy practice. It can be concluded that the PDR, implicating the ADR, in unselected patients can be lower in individual endoscopists than recommended in the literature. This highly depends on the case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.

  5. Capsules made from prefabricated thin films

    NASA Astrophysics Data System (ADS)

    Amstad, Esther

    2018-02-01

    Capsules are composed of a core, typically a liquid containing active substances, and a surrounding shell. They are used to delay the degradation of active ingredients, protect them from reacting or interacting with substances contained in the surrounding shell, or to prevent premature consumption of encapsulants (1, 2). The performance of capsules is often determined by their permeability toward encapsulants and stability against rupture; these parameters can be adjusted with the composition, structure, and thickness of the shell (3, 4). Mechanically robust capsules with a minimal permeability even toward low molecular weight substances often have rather thick shells (5). On page 775 of this issue, Kumar et al. (6) report an elegant process to fabricate capsules with very thin, rigid shells that display a low permeability even toward small encapsulants.

  6. Simple transmission Raman measurements using a single multivariate model for analysis of pharmaceutical samples contained in capsules of different colors.

    PubMed

    Lee, Yeojin; Kim, Jaejin; Lee, Sanguk; Woo, Young-Ah; Chung, Hoeil

    2012-01-30

    Direct transmission Raman measurements for analysis of pharmaceuticals in capsules are advantageous since they can be used to determine active pharmaceutical ingredient (API) concentrations in a non-destructive manner and with much less fluorescence background interference from the capsules themselves compared to conventional back-scattering measurements. If a single calibration model such as developed from spectra simply collected in glass vials could be used to determine API concentrations of samples contained in capsules of different colors rather than constructing individual models for each capsule color, the utility of transmission measurements would be further enhanced. To evaluate the feasibility, transmission Raman spectra of binary mixtures of ambroxol and lactose were collected in a glass vial and a partial least squares (PLS) model for the determination of ambroxol concentration was developed. Then, the model was directly applied to determine ambroxol concentrations of samples contained in capsules of 4 different colors (blue, green, white and yellow). Although the prediction performance was slightly degraded when the samples were placed in blue or green capsules, due to the presence of weak fluorescence, accurate determination of ambroxol was generally achieved in all cases. The prediction accuracy was also investigated when the thickness of the capsule was varied. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Nurse-Performed Endoscopy: Implications for the Nursing Profession in Australia.

    PubMed

    Duffield, Christine; Chapman, Susan; Rowbotham, Samantha; Blay, Nicole

    2017-02-01

    Increasing demands for health care globally often lead to discussions about expanding the involvement of nurses in a range of nontraditional roles. Several countries have introduced nurse endoscopists as a means of easing the burden of demand for a range of endoscopic procedures. A shortage of medical staff in Australia combined with increasing demand for endoscopy led to the implementation of nurse endoscopists as a pilot program in the state of Queensland, where a nurse practitioner model was implemented, and Victoria, where an advanced practice model was used. This article will discuss the implementation of and responses from the nursing, medical, and policy community to nurse-performed endoscopy in this country. Regarding health policy, access to cancer screening may be improved by providing nurses with advanced training to safely perform endoscopy procedures. Moreover, issues of nurse credentialing and payment need to be considered appropriate to each country's health system model.

  8. Evaluation of topical pharyngeal anaesthesia by benzocaine lozenge for upper endoscopy.

    PubMed

    Shaoul, R; Higaze, H; Lavy, A

    2006-08-15

    Among the randomized controlled trials evaluating the effect of pharyngeal anaesthesia only some suggest benefit. Spray is irritating for some people and leaves bitter taste in the throat. We hypothesized that delivering the local anaesthetic as a sucking lozenge would benefit the patients in terms of decreasing anxiety and will improve procedure performance and patient tolerance. To determine whether benzocaine/tyrothricin sucking lozenges with conscious sedation is superior to conscious sedation alone, with respect to procedure performance and tolerance in patients undergoing upper endoscopy. One hundred and seventy-four adult patients undergoing upper endoscopy with conscious sedation completed the study. They were randomized to receive sucking lozenge containing benzocaine or placebo before the procedure. Patients were asked to rate prestudy anxiety, tolerance for topical pharyngeal anaesthesia, comfort during endoscopy, degree of difficulty of intubation, postprocedure throat discomfort and willingness to undergo subsequent examinations using a 10-cm visual analogue scale. Endoscopists were asked to estimate the ease of oesophageal intubation and procedure performance. No significant statistical differences regarding all the points studied were found between the groups. Topical pharyngeal anaesthesia with benzocaine/tyrothricin lozenges with conscious sedation has no advantages over conscious sedation alone in patients undergoing upper endoscopy.

  9. [Evaluation of nopal capsules in diabetes mellitus].

    PubMed

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P < 0.01 glucose and cholesterol, P = NS triglycerides). In healthy individuals glycemia did not change with nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  10. Sedation in gastrointestinal endoscopy: current issues.

    PubMed

    Triantafillidis, John K; Merikas, Emmanuel; Nikolakis, Dimitrios; Papalois, Apostolos E

    2013-01-28

    Diagnostic and therapeutic endoscopy can successfully be performed by applying moderate (conscious) sedation. Moderate sedation, using midazolam and an opioid, is the standard method of sedation, although propofol is increasingly being used in many countries because the satisfaction of endoscopists with propofol sedation is greater compared with their satisfaction with conventional sedation. Moreover, the use of propofol is currently preferred for the endoscopic sedation of patients with advanced liver disease due to its short biologic half-life and, consequently, its low risk of inducing hepatic encephalopathy. In the future, propofol could become the preferred sedation agent, especially for routine colonoscopy. Midazolam is the benzodiazepine of choice because of its shorter duration of action and better pharmacokinetic profile compared with diazepam. Among opioids, pethidine and fentanyl are the most popular. A number of other substances have been tested in several clinical trials with promising results. Among them, newer opioids, such as remifentanil, enable a faster recovery. The controversy regarding the administration of sedation by an endoscopist or an experienced nurse, as well as the optimal staffing of endoscopy units, continues to be a matter of discussion. Safe sedation in special clinical circumstances, such as in the cases of obese, pregnant, and elderly individuals, as well as patients with chronic lung, renal or liver disease, requires modification of the dose of the drugs used for sedation. In the great majority of patients, sedation under the supervision of a properly trained endoscopist remains the standard practice worldwide. In this review, an overview of the current knowledge concerning sedation during digestive endoscopy will be provided based on the data in the current literature.

  11. Sedation in gastrointestinal endoscopy: Current issues

    PubMed Central

    Triantafillidis, John K; Merikas, Emmanuel; Nikolakis, Dimitrios; Papalois, Apostolos E

    2013-01-01

    Diagnostic and therapeutic endoscopy can successfully be performed by applying moderate (conscious) sedation. Moderate sedation, using midazolam and an opioid, is the standard method of sedation, although propofol is increasingly being used in many countries because the satisfaction of endoscopists with propofol sedation is greater compared with their satisfaction with conventional sedation. Moreover, the use of propofol is currently preferred for the endoscopic sedation of patients with advanced liver disease due to its short biologic half-life and, consequently, its low risk of inducing hepatic encephalopathy. In the future, propofol could become the preferred sedation agent, especially for routine colonoscopy. Midazolam is the benzodiazepine of choice because of its shorter duration of action and better pharmacokinetic profile compared with diazepam. Among opioids, pethidine and fentanyl are the most popular. A number of other substances have been tested in several clinical trials with promising results. Among them, newer opioids, such as remifentanil, enable a faster recovery. The controversy regarding the administration of sedation by an endoscopist or an experienced nurse, as well as the optimal staffing of endoscopy units, continues to be a matter of discussion. Safe sedation in special clinical circumstances, such as in the cases of obese, pregnant, and elderly individuals, as well as patients with chronic lung, renal or liver disease, requires modification of the dose of the drugs used for sedation. In the great majority of patients, sedation under the supervision of a properly trained endoscopist remains the standard practice worldwide. In this review, an overview of the current knowledge concerning sedation during digestive endoscopy will be provided based on the data in the current literature. PMID:23382625

  12. Cell cycle constraints on capsulation and bacteriophage susceptibility

    PubMed Central

    Ardissone, Silvia; Fumeaux, Coralie; Bergé, Matthieu; Beaussart, Audrey; Théraulaz, Laurence; Radhakrishnan, Sunish Kumar; Dufrêne, Yves F; Viollier, Patrick H

    2014-01-01

    Despite the crucial role of bacterial capsules in pathogenesis, it is still unknown if systemic cues such as the cell cycle can control capsule biogenesis. In this study, we show that the capsule of the synchronizable model bacterium Caulobacter crescentus is cell cycle regulated and we unearth a bacterial transglutaminase homolog, HvyA, as restriction factor that prevents capsulation in G1-phase cells. This capsule protects cells from infection by a generalized transducing Caulobacter phage (φCr30), and the loss of HvyA confers insensitivity towards φCr30. Control of capsulation during the cell cycle could serve as a simple means to prevent steric hindrance of flagellar motility or to ensure that phage-mediated genetic exchange happens before the onset of DNA replication. Moreover, the multi-layered regulatory circuitry directing HvyA expression to G1-phase is conserved during evolution, and HvyA orthologues from related Sinorhizobia can prevent capsulation in Caulobacter, indicating that alpha-proteobacteria have retained HvyA activity. DOI: http://dx.doi.org/10.7554/eLife.03587.001 PMID:25421297

  13. Experimental measurement on movement of spiral-type capsule endoscope

    PubMed Central

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. PMID:26848279

  14. Experimental measurement on movement of spiral-type capsule endoscope.

    PubMed

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability.

  15. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding

    PubMed Central

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-01-01

    AIM: To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. METHODS: Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. RESULTS: In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. CONCLUSION: The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding. PMID:25009396

  16. Role of endoscopy in inflammatory bowel disease

    PubMed Central

    Bharadwaj, Shishira; Narula, Neeraj; Tandon, Parul; Yaghoobi, Mohammad

    2018-01-01

    Abstract Crohn’s disease (CD) and ulcerative colitis (UC) constitute the two most common phenotypes of inflammatory bowel disease (IBD). Ileocolonoscopy with biopsy has been considered the gold standard for the diagnosis of IBD. Differential diagnosis of CD and UC is important, as their medical and surgical treatment modalities and prognoses can be different. However, approximately 15% of patients with IBD are misdiagnosed as IBD unclassified due to the lack of diagnostic certainty of CD or UC. Recently, there has been increased recognition of the role of the therapeutic endoscopist in the field of IBD. Newer imaging techniques have been developed to aid in the differentiation of UC vs CD. Furthermore, endoscopic balloon dilation and stenting have become an integral part of the therapeutic armamentarium of CD stricture management. Endoscopic ultrasound has been recognized as being more accurate than magnetic resonance imaging in detecting perianal fistulae in patients with CD. Additionally, chromoendoscopy may help to detect dysplasia earlier compared with white-light colonoscopy. Hence, interventional endoscopy has become a cornerstone in the diagnosis, treatment and management of IBD complications. The role of endoscopy in the field of IBD has significantly evolved in recent years from small-bowel imaging to endoscopic balloon dilation and use of chormoendoscopy in dysplasia surveillance. In this review article, we discuss the current evidence on interventional endoscopy in the diagnosis, treatment and management of IBD compications. PMID:29780594

  17. Fabrication of capsule assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1973-01-01

    Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

  18. Stopping mechanism for capsule endoscope using electrical stimulus.

    PubMed

    Woo, Sang Hyo; Kim, Tae Wan; Cho, Jin Ho

    2010-01-01

    An ingestible capsule, which has the ability to stop at certain locations in the small intestine, was designed and implemented to monitor intestinal diseases. The proposed capsule can contract the small intestine by using electrical stimuli; this contraction causes the capsule to stop when the maximum static frictional force (MSFF) is larger than the force of natural peristalsis. In vitro experiments were carried out to verify the feasibility of the capsule, and the results showed that the capsule was successfully stopped in the small intestine. Various electrodes and electrical stimulus parameters were determined on the basis of the MSFF. A moderate increment of the MSFF (12.7 +/- 4.6 gf at 5 V, 10 Hz, and 5 ms) and the maximum increment of the MSFF (56.5 +/- 9.77 gf at 20 V, 10 Hz, and 5 ms) were obtained, and it is sufficient force to stop the capsule.

  19. Identification of a functional capsule locus in Streptococcus mitis.

    PubMed

    Rukke, H V; Hegna, I K; Petersen, F C

    2012-04-01

    The polysaccharide capsule of Streptococcus pneumoniae is a hallmark for virulence in humans. In its close relative Streptococcus mitis, a common human commensal, analysis of the sequenced genomes of six strains revealed the presence of a putative capsule locus in four of them. We constructed an isogenic S. mitis mutant from the type strain that lacked the 19 open reading frames in the capsule locus (Δcps mutant), using a deletion strategy similar to previous capsule functional studies in S. pneumoniae. Transmission electron microscopy and atomic force microscopy revealed a capsule-like structure in the S. mitis type strain that was absent or reduced in the Δcps mutant. Since S. mitis are predominant oral colonizers of tooth surfaces, we addressed the relevance of the capsule locus for the S. mitis overall surface properties, autoaggregation and biofilm formation. The capsule deletion resulted in a mutant with approximately two-fold increase in hydrophobicity. Binding to the Stains-all cationic dye was reduced by 40%, suggesting a reduction in the overall negative surface charge of the mutant. The mutant exhibited also increased autoaggregation in coaggregation buffer, and up to six-fold increase in biofilm levels. The results suggested that the capsule locus is associated with production of a capsule-like structure in S. mitis and indicated that the S. mitis capsule-like structure may confer surface attributes similar to those associated with the capsule in S. pneumoniae. © 2011 John Wiley & Sons A/S.

  20. TIME - MAKING THE BEST OF IT! A Fieldwork Study Outlining Time in Endoscopy Facilities for Short-Term Stay

    PubMed Central

    Bundgaard, Karin; Sørensen, Erik E.; Delmar, Charlotte

    2016-01-01

    Aim: This paper focus on nursing and time in endoscopy facilities for short-term stay aiming to explore aspects of time in this setting and how expectations from the healthcare organisation, patients and nurses are expressed and met when managing nursing time. Background: Former research primarily focuses on the subject of time in the understanding of duration where having more time is closely associated with the ability to deliver better quality nursing care. The main concern is the nurses’ increased number of tasks and the decreased length of time at their disposal. However, few studies describe nursing when time is sparse, and the possibility of providing individualised nursing within a very short span of time. Design: Inspired by practical ethnographic principles, a fieldwork study was performed in high technology endoscopy clinics during 2008-2010. Methods: Data triangulation included participant observation, participant reports and patients and nurses semi-structured interviews. Results/Findings: The issue of time was an interwoven part of life in the productive endoscopy units. The understanding of time related to the main category: ‘Time - making the best of it’, and the sub categories “Responsibility of time”, “Information and preparation”, and “Time wasters”. Conclusion: The study underlines the possibility of combining the health care systems, patients and the nurses’ perspectives on and expectations of how to spend nursing time in endoscopy settings. In successful patient pathways nursing maximize patient outcome, support the goals of the healthcare organisations, is reliable, assure, tangible, empathic and responsive, and is individually tailored to the patient’s needs. The study contributes by underlining the importance of discussing not how to get more time in clinical practice but instead how to spend the time in the best way possible. PMID:27347251

  1. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  2. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  3. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin sodium...

  4. Production, deformation and mechanical investigation of magnetic alginate capsules

    NASA Astrophysics Data System (ADS)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  5. Recent Advances in Endoscopy.

    PubMed

    Wallace, Michael B; Wang, Kenneth K; Adler, Douglas G; Rastogi, Amit

    2017-08-01

    In this narrative review, invited by the Editors of Gastroenterology, we summarize recent advances in the field of gastrointestinal endoscopy. We have chosen articles published primarily in the past 2-3 years. Although a thorough literature review was performed for each topic, the nature of the article is subjective and systematic and is based on the authors' experience and expertise regarding articles we believed were most likely to be of high clinical and scientific importance. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  6. Towards active capsular endoscopy: preliminary results on a legged platform.

    PubMed

    Menciassi, Arianna; Stefanini, Cesare; Orlandi, Giovanni; Quirini, Marco; Dario, Paolo

    2006-01-01

    This paper illustrates the problem of active locomotion in the gastrointestinal tract for endoscopic capsules. Authors analyze the problem of locomotion in unstructured, flexible and tubular environments and explain the reasons leading to the selection of a legged system. They present a theoretical simulation of legged capsule locomotion, which is used to define the optimal parameters for capsule design and gait selection. Finally, a legged capsule--about 3 cm3 in volume--is presented; it consists of 4 back legs whose actuation is achieved thanks to a miniaturized DC brushless motor. In vitro tests demonstrate good performance in terms of achievable speed (92 mm/min).

  7. Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.

    PubMed

    Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi

    2014-08-07

    Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.

  8. Gettering capsule for removing oxygen from liquid lithium systems

    NASA Technical Reports Server (NTRS)

    Tower, L. K.; Breitwieser, R.

    1973-01-01

    Capsule consisting of tantalum shell lined with tantalum screen and partially filled with lithium and pieces of yttrium is immersed in hot lithium stream. Oxygen is removed from stream by being absorbed by gettering capsule. Oxygen passes through capsule wall and into lithium inside capsule where it reacts with yttrium to form Y2O3.

  9. Use and impact of early endoscopy in elderly patients with peptic ulcer hemorrhage: a population-based analysis.

    PubMed

    Cooper, Gregory S; Kou, Tzyung Doug; Wong, Richard C K

    2009-08-01

    Upper endoscopy performed within 1 day of presentation, or early endoscopy, has been proposed as an intervention to improve the efficiency and outcomes of care for patients with peptic ulcer hemorrhage. However, the use and outcomes have not been studied in a national, U.S.-based sample. To determine the prevalence and associated outcomes of early versus delayed endoscopy in bleeding peptic ulcers. Using a 5% random sample of inpatient and outpatient Medicare claims from 2004 in patients aged 66 years and older (mean [standard deviation] age 78.4 +/- 7.7 years), we identified 2592 patients, all of whom underwent endoscopy. Univariate and multivariate models were used to determine factors associated with 30-day mortality, upper GI surgery, and length of hospital stay. Early endoscopy was performed in 1854 patients (71.5%) and was somewhat more common with outpatient management. Early endoscopy was independently associated with a significant decrease in the length of hospital stay (-1.95 days, 95% CI, -2.60 to -1.29 days) as well as a lower likelihood of surgery (odds ratio, 0.37; 95% CI, 0.21-0.66). Early endoscopy was not associated with 30-day mortality in either univariate or multivariate analyses. Use of claims data lacking clinical detail and restriction to the Medicare-age population. In this population-based study of older patients with peptic ulcer hemorrhage, early endoscopy was associated with increased efficiency of care, lower rates of surgery, and potentially improved control of hemorrhage. Thus, unless specific contraindications exist, the data support the routine use of early endoscopy.

  10. Parental and youth understanding of the informed consent process for pediatric endoscopy.

    PubMed

    Jubbal, Kevin; Chun, Stanford; Chang, Jeremy; Zhang, Sherry; Terrones, Laura; Huang, Jeannie S

    2015-06-01

    Informed consent (IC) is an essential communication between patient/representative and physician that acknowledges patient autonomy; assent is the equivalent process performed between youth and physician. For clinical procedures involving youth, only the IC process between guardian/parent and physician is required to be performed. Nevertheless, experts recommend that youth undergo assent whenever possible. In the present study, we explored both parental and youth understanding of required IC elements in IC discussions before pediatric endoscopy. Following signing of IC documents on the day of endoscopy at a tertiary care academic medical center, youth and their parents underwent structured interviews to assess comprehension of key elements of the IC process. A total of 88 children and adolescents and their parents were evaluated. Two youth and 12 parents demonstrated comprehensive understanding of key IC elements for pediatric endoscopy. Suboptimal youth understanding was demonstrated for nature of the procedure (25% with adequate understanding) and related risks (17%), and alternatives (14%) to the procedure. Suboptimal parental understanding was demonstrated for procedure alternatives (24%). Youth overall understanding of IC varied by age, whereas parental global understanding of IC varied by physician. Understanding of IC performed for pediatric endoscopy could be improved in both parents and youth. Our findings suggest that interventions targeting parents, youth, and physicians may be helpful. Further study is needed to determine whether our findings are representative of IC understanding at other pediatric endoscopy centers.

  11. Motion of an elastic capsule in a square microfluidic channel.

    PubMed

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  12. Motion of an elastic capsule in a square microfluidic channel

    PubMed Central

    Kuriakose, S.; Dimitrakopoulos, P.

    2013-01-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e. small, moderate and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to, and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross-section in the upstream portion of large capsules is non-axisymmetric (i.e. square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a−2 for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux−u~h~a−2

  13. Computer vision and augmented reality in gastrointestinal endoscopy

    PubMed Central

    Mahmud, Nadim; Cohen, Jonah; Tsourides, Kleovoulos; Berzin, Tyler M.

    2015-01-01

    Augmented reality (AR) is an environment-enhancing technology, widely applied in the computer sciences, which has only recently begun to permeate the medical field. Gastrointestinal endoscopy—which relies on the integration of high-definition video data with pathologic correlates—requires endoscopists to assimilate and process a tremendous amount of data in real time. We believe that AR is well positioned to provide computer-guided assistance with a wide variety of endoscopic applications, beginning with polyp detection. In this article, we review the principles of AR, describe its potential integration into an endoscopy set-up, and envisage a series of novel uses. With close collaboration between physicians and computer scientists, AR promises to contribute significant improvements to the field of endoscopy. PMID:26133175

  14. Light weight escape capsule for fighter aircraft

    NASA Technical Reports Server (NTRS)

    Robert, James A.

    1988-01-01

    Emergency crew escape capabilities have been less than adequate for fighter aircraft since before WW II. From the over-the-side bailout of those days through the current ejection seat with a rocket catapult, escaping from a disabled aircraft has been risky at best. Current efforts are underway toward developing a high-tech, smart ejection seat that will give fighter pilots more room to live in the sky, but an escape capsule is needed to meet current and future fighter envelopes. Escape capsules have a bad reputation due to past examples of high weight, poor performance and great complexity. However, the advantages available demand that a capsule be developed. This capsule concept will minimize the inherent disavantages and incorporate the benefits while integrating all aspects of crew station design. The resulting design is appropriate for a crew station of the year 2010 and includes improved combat acceleration protection, chemical or biological combat capability, improved aircraft to escape system interaction, and the highest level of escape performance achievable. The capsule is compact, which can allow a reduced aircraft size and weighs only 1200 lb. The escape system weight penalty is only 120 lb higher than that for the next ejection seat and the capsule has a corresponding increase in performance.

  15. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    NASA Astrophysics Data System (ADS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  16. Polar tent for reduced perturbation of NIF ignition capsules

    NASA Astrophysics Data System (ADS)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  17. The Prevalence of Barrett Esophagus Diagnosed in the Second Endoscopy

    PubMed Central

    Suna, Nuretdin; Parlak, Erkan; Kuzu, Ufuk Baris; Yildiz, Hakan; Koksal, Aydin Seref; Oztas, Erkin; Sirtas, Zeliha; Yuksel, Mahmut; Aydinli, Onur; Bilge, Zulfikar; Taskiran, Ismail; Sasmaz, Nurgul

    2016-01-01

    Abstract At present, we do not know the exact prevalence of Barrett esophagus (BE) developing later in patients without BE in their first endoscopic screening. The purpose of this study was to determine the prevalence of BE on the second endoscopic examination of patients who had no BE in their first endoscopic examination. The data of the patients older than 18 years who had undergone upper gastrointestinal system endoscopy more than once at the endoscopy unit of our clinic during the last 6 years were retrospectively analyzed. During the last 6 years, 44,936 patients had undergone at least one endoscopic examination. Among these patients, 2701 patients who had more than one endoscopic screening were included in the study. Of the patients, 1276 (47.3%) were females and 1425 (52.7%) were males, with an average age of 54.9 (18–94) years. BE was diagnosed in 18 (0.66%) of the patients who had no BE in the initial endoscopic examination. The patients with BE had reflux symptoms in their medical history and in both endoscopies, they revealed a higher prevalence of lower esophageal sphincter laxity, hiatal hernia, and reflux esophagitis when compared to patients without BE (P < 0.001). Our study showed that in patients receiving no diagnosis of BE on their first endoscopic examination performed for any reason, the prevalence of BE on their second endoscopy within 6 years was very low (0.66%). PMID:27057907

  18. Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection.

    PubMed

    Regeling, Bianca; Thies, Boris; Gerstner, Andreas O H; Westermann, Stephan; Müller, Nina A; Bendix, Jörg; Laffers, Wiebke

    2016-08-13

    Hyperspectral imaging (HSI) is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope's fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details.

  19. Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection

    PubMed Central

    Regeling, Bianca; Thies, Boris; Gerstner, Andreas O. H.; Westermann, Stephan; Müller, Nina A.; Bendix, Jörg; Laffers, Wiebke

    2016-01-01

    Hyperspectral imaging (HSI) is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope’s fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details. PMID:27529255

  20. Virtual reality simulation training for health professions trainees in gastrointestinal endoscopy.

    PubMed

    Walsh, Catharine M; Sherlock, Mary E; Ling, Simon C; Carnahan, Heather

    2012-06-13

    Traditionally, training in gastrointestinal endoscopy has been based upon an apprenticeship model, with novice endoscopists learning basic skills under the supervision of experienced preceptors in the clinical setting. Over the last two decades, however, the growing awareness of the need for patient safety has brought the issue of simulation-based training to the forefront. While the use of simulation-based training may have important educational and societal advantages, the effectiveness of virtual reality gastrointestinal endoscopy simulators has yet to be clearly demonstrated. To determine whether virtual reality simulation training can supplement and/or replace early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. Health professions, educational and computer databases were searched until November 2011 including The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, Scopus, Web of Science, Biosis Previews, CINAHL, Allied and Complementary Medicine Database, ERIC, Education Full Text, CBCA Education, Career and Technical Education @ Scholars Portal, Education Abstracts @ Scholars Portal, Expanded Academic ASAP @ Scholars Portal, ACM Digital Library, IEEE Xplore, Abstracts in New Technologies and Engineering and Computer & Information Systems Abstracts. The grey literature until November 2011 was also searched. Randomised and quasi-randomised clinical trials comparing virtual reality endoscopy (oesophagogastroduodenoscopy, colonoscopy and sigmoidoscopy) simulation training versus any other method of endoscopy training including conventional patient-based training, in-job training, training using another form of endoscopy simulation (e.g. low-fidelity simulator), or no training (however defined by authors) were included.  Trials comparing one method of virtual reality training versus

  1. Quantitative endoscopy: initial accuracy measurements.

    PubMed

    Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P

    2000-02-01

    The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.

  2. General route for the assembly of functional inorganic capsules.

    PubMed

    Akartuna, Ilke; Tervoort, Elena; Studart, André R; Gauckler, Ludwig J

    2009-11-03

    Semipermeable, hollow capsules are attractive materials for the encapsulation and delivery of active agents in food processing, pharmaceutical and agricultural industries, and biomedicine. These capsules can be produced by forming a solid shell of close packed colloidal particles, typically polymeric particles, at the surface of emulsion droplets. However, current methods to prepare such capsules may involve multistep chemical procedures to tailor the surface chemistry of particles or are limited to particles that exhibit inherently the right hydrophobic-hydrophilic balance to adsorb around emulsion droplets. In this work, we describe a general and simple method to fabricate semipermeable, inorganic capsules from emulsion droplets stabilized by a wide variety of colloidal metal oxide particles. The assembly of particles at the oil-water interface is induced by the in situ hydrophobization of the particle surface through the adsorption of short amphiphilic molecules. The adsorption of particles at the interface leads to stable capsules comprising a single layer of particles in the outer shell. Such capsules can be used in the wet state or can be further processed into dry capsules. The permeability of the capsules can be modified by filling the interstices between the shell particles with polymeric or inorganic species. Functional capsules with biocompatible, bioresorbable, heat-resistant, chemical-resistant, and magnetic properties were prepared using alumina, silica, iron oxide, or tricalcium phosphate as particles in the shell.

  3. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    PubMed

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  4. 21 CFR 520.260 - n-Butyl chloride capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false n-Butyl chloride capsules. 520.260 Section 520.260... DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.260 n-Butyl chloride capsules. (a)(1) Specifications. n-Butyl chloride capsules, veterinary contain 272 milligrams or 816 milligrams...

  5. IRRADIATION-CAPSULE STUDY OF URANIUM MONOCARBIDE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, R.B.; Stahl, D.; Stang, J.H.

    1960-03-01

    Small cylindrical specimens of enriched UC were irradiated to evaluate usefulness as a high-temperature fuel for stationary power reactors. Detailed thermal and nuclear analyses were made to arrive at an appropriate capsule design on the basis of target specimen center-line temperature ( approximately 1500 deg F), specimen surface temperature (1100 deg F), specimen composition (U--5 wt.% C), and acapsule o.d. of 1.125 in. Temperature data from thermocouples inside the capsule indicated that five of the six capsules irradiated operated at close to the design conditions. Irradiation periods for individual capsules were varied to give burnups ranging from 1,000 to 20,000more » Mwd/t of U. Preliminary evidence indicates that this range of burnups was achieved. By using temperature and heat-flux data from the actual irradiations to estimate effective in-pile specimen thermal conductivities, it was found that the conductivity did not appear to vary during the exposures. (auth)« less

  6. A blue optical filter for narrow-band imaging in endoscopic capsules

    NASA Astrophysics Data System (ADS)

    Silva, M. F.; Ghaderi, M.; Goncalves, L. M.; de Graaf, G.; Wolffenbuttel, R. F.; Correia, J. H.

    2014-05-01

    This paper presents the design, simulation, fabrication, and characterization of a thin-film Fabry-Perot resonator composed of titanium dioxide (TiO2) and silicon dioxide (SiO2) thin-films. The optical filter is developed to be integrated with a light emitting diode (LED) for enabling narrow-band imaging (NBI) in endoscopy. The NBI is a high resolution imaging technique that uses spectrally centered blue light (415 nm) and green light (540 nm) to illuminate the target tissue. The light at 415 nm enhances the imaging of superficial veins due to their hemoglobin absorption, while the light at 540 nm penetrates deeper into the mucosa, thus enhances the sub-epithelial vessels imaging. Typically the endoscopes and endoscopic capsules use white light for acquiring images of the gastrointestinal (GI) tract. However, implementing the NBI technique in endoscopic capsules enhances their capabilities for the clinical applications. A commercially available blue LED with a maximum peak intensity at 404 nm and Full Width Half Maximum (FWHM) of 20 nm is integrated with a narrow band blue filter as the NBI light source. The thin film simulations show a maximum spectral transmittance of 36 %, that is centered at 415 nm with FWHM of 13 nm for combined the blue LED and a Fabry Perot resonator system. A custom made deposition scheme was developed for the fabrication of the blue optical filter by RF sputtering. RF powered reactive sputtering at 200 W with the gas flows of argon and oxygen that are controlled for a 5:1 ratio gives the optimum optical conditions for TiO2 thin films. For SiO2 thin films, a non-reactive RF sputtering at 150 W with argon gas flow at 15 sccm results in the best optical performance. The TiO2 and SiO2 thin films were fully characterized by an ellipsometer in the wavelength range between 250 nm to 1600 nm. Finally, the optical performance of the blue optical filter is measured and presented.

  7. Gastrointestinal endoscopy: infection and disinfection.

    PubMed

    O'Connor, H J; Axon, A T

    1983-11-01

    The past decade has seen the development of an array of complex flexible fibreoptic instruments for gastrointestinal (GI) endoscopy, and an increasing use of these for diagnostic and therapeutic purposes. It has been recognised more recently that the use of contaminated endoscopic equipment can lead to serious and occasionally fatal infections. Infection with a wide variety of micro-organisms has been reported following oesophago-gastroduodenoscopy (OGD) and endoscopic retrograde cholangio-pancreatography (ERCP).

  8. Gastrointestinal endoscopy: infection and disinfection.

    PubMed Central

    O'Connor, H J; Axon, A T

    1983-01-01

    The past decade has seen the development of an array of complex flexible fibreoptic instruments for gastrointestinal (GI) endoscopy, and an increasing use of these for diagnostic and therapeutic purposes. It has been recognised more recently that the use of contaminated endoscopic equipment can lead to serious and occasionally fatal infections. Infection with a wide variety of micro-organisms has been reported following oesophago-gastroduodenoscopy (OGD) and endoscopic retrograde cholangio-pancreatography (ERCP). PMID:6414894

  9. Ultrathin endoscopy versus high-resolution endoscopy for diagnosing superficial gastric neoplasia.

    PubMed

    Toyoizumi, Hirobumi; Kaise, Mitsuru; Arakawa, Hiroshi; Yonezawa, Jin; Yoshida, Yukinaga; Kato, Masayuki; Yoshimura, Noboru; Goda, Ken-ichi; Tajiri, Hisao

    2009-08-01

    Ultrathin endoscopy (UTE) is an acceptable and cost-effective alternative to EGD with the patient under sedation, although the diagnostic accuracy of UTE is not well established. To compare the diagnostic accuracy of UTE and high-resolution endoscopy (HRE) for superficial gastric neoplasia. Prospective comparative study. Academic center. Patients with or without superficial gastric neoplasia underwent peroral UTE and HRE, back-to-back in a random order while under standard sedation. The procedures were performed by 2 endoscopists who were blinded to the clinical information. The rate of missed lesions and misdiagnosis, sensitivity, and specificity for the diagnosis of gastric neoplasia when using pathology as the reference standard. In total, 126 lesions (41 superficial gastric neoplasias, 85 nonneoplastic lesions) were recorded in 57 enrolled patients. For the diagnosis of gastric neoplasia, the sensitivity of UTE (58.5%) was significantly (P = .021) lower than that of HRE (78%), and the specificity of UTE (91.8%) was significantly (P = .014) lower than that of HRE (100%). The rate of missed lesions and misdiagnosis of gastric neoplasias when using UTE (41.5%) was significantly (P > .001) higher than that of HRE (22.0%). The corresponding rate of neoplasias at the proximal portion (fornix and corpus) when using UTE (29%) was significantly (P = .002) higher than that of HRE (7.2%), although the rates of neoplasias at the distal portion (angulus and antrum) were comparable for UTE and HRE. Small sample numbers in an enriched population. The diagnostic accuracy of UTE is significantly lower than that of HRE for superficial gastric neoplasia, and this difference is particularly striking for neoplasias in the proximal stomach. For UTE to be used as an alternative modality, improvements in optical quality and the incorporation of additional procedures, including close-range observations and chromoendoscopy, are required to enhance visualization.

  10. Outcomes of Propofol Sedation During Emergency Endoscopy Performed for Upper Gastrointestinal Bleeding.

    PubMed

    Park, Chan Hyuk; Han, Dong Soo; Jeong, Jae Yoon; Eun, Chang Soo; Yoo, Kyo-Sang; Jeon, Yong Cheol; Sohn, Joo Hyun

    2016-03-01

    Although propofol-based sedation can be used during emergency endoscopy for upper gastrointestinal bleeding (UGIB), there is a potential risk of sedation-related adverse events, especially in patients with variceal bleeding. We compared adverse events related to propofol-based sedation during emergency endoscopy between patients with non-variceal and variceal bleeding. Clinical records of patients who underwent emergency endoscopy for UGIB under sedation were reviewed. Adverse events, including shock, hypoxia, and paradoxical reaction, were compared between the non-variceal and variceal bleeding groups. Of 703 endoscopies, 539 and 164 were performed for non-variceal and variceal bleeding, respectively. Shock was more common in patients with variceal bleeding compared to those with non-variceal bleeding (12.2 vs. 3.5%, P < 0.001). All patients except one recovered from shock after normal saline hydration, and emergency endoscopy could be finished without interruption in most cases. The incidence of hypoxia and paradoxical reaction did not differ based on the source of bleeding (non-variceal bleeding vs. variceal bleeding: hypoxia, 3.5 vs. 1.8%, P = 0.275; paradoxical reaction interfering with the procedure, 4.1 vs. 5.5%, P = 0.442). Although shock was more common in patients with variceal bleeding compared to those with non-variceal bleeding, most cases could be controlled without procedure interruption. Paradoxical reaction, rather than shock or hypoxia, was the most common cause of procedure interruption in patients with variceal bleeding, but the rate did not differ between patients with non-variceal and variceal bleeding.

  11. Analysis of Fission Products on the AGR-1 Capsule Components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul A. Demkowicz; Jason M. Harp; Philip L. Winston

    2013-03-01

    The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed tomore » determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.« less

  12. Capsule endoscope localization based on computer vision technique.

    PubMed

    Liu, Li; Hu, Chao; Cai, Wentao; Meng, Max Q H

    2009-01-01

    To build a new type of wireless capsule endoscope with interactive gastrointestinal tract examination, a localization and orientation system is needed for tracking 3D location and 3D orientation of the capsule movement. The magnetic localization and orientation method produces only 5 DOF, but misses the information of rotation angle along capsule's main axis. In this paper, we presented a complementary orientation approach for the capsule endoscope, and the 3D rotation can be determined by applying computer vision technique on the captured endoscopic images. The experimental results show that the complementary orientation method has good accuracy and high feasibility.

  13. Serology for Helicobacter pylori compared with symptom questionnaires in screening before direct access endoscopy.

    PubMed

    Mendall, M A; Jazrawi, R P; Marrero, J M; Molineaux, N; Levi, J; Maxwell, J D; Northfield, T C

    1995-03-01

    This prospective study aimed to compare serology for Helicobacter pylori with two, symptom questionnaires in screening patients before direct access endoscopy. Methods were compared in terms of the number of endoscopies saved and pathology missed in 315 patients referred to a gastroenterology unit by 65 local GPs. The serology used was based on an acid glycine extract of H pylori. One in-house questionnaire was based on the Glasgow dyspepsia (GLADYS) system and the other questionnaire was that reported by Holdstock et al. A cut off point of 6.3 U/ml for H pylori serology was selected for screening patients (97% sensitive and 75% specific). Serology was combined with a history of NSAID usage in determining who should have endoscopy. For the in-house questionnaire, a cut off score of more than 8 out of a possible maximum of 18 was chosen, after prior evaluation in 118 patients referred for direct access endoscopy (the sensitivity for detection of peptic ulcer was 88%, specificity 61%). A cut off score of more than 412 was used for the Holdstock questionnaire. In patients under 45 years, serology detected more peptic ulcers than the in-house questionnaire and the Holdstock questionnaire (27/28 v 24/28, NS and v 20/28, p < 0.05 respectively). The Holdstock questionnaire saved significantly more endoscopies than the other two methods (76/149 v 57/149 for the in-house questionnaire, p = 0.05 and 59/149 for serology, p = 0.05). In all age groups combined, serology was significantly better than the in-house and Holdstock questionnaires at detecting peptic ulcers and gastric cancer (61/63, 52/63, p<0.02, and 50/63, p<0.01 respectively). But serology saved significantly fewer endoscopies (89/315, 135/315, p<0.005, and 119/315, p<0.05 respectively). Serology was inferior to the Holdstock questionnaire at detecting severe oesophagitis. It is concluded that serology is the method of choice in screening before direct access upper gastrointestinal endoscopy in those under 45

  14. Performance evaluation of wireless communications through capsule endoscope.

    PubMed

    Takizawa, Kenichi; Aoyagi, Takahiro; Hamaguchi, Kiyoshi; Kohno, Ryuji

    2009-01-01

    This paper presents a performance evaluation of wireless communications applicable into a capsule endoscope. A numerical model to describe the received signal strength (RSS) radiated from a capsule-sized signal generator is derived through measurements in which a liquid phantom that has equivalent electrical constants is used. By introducing this model and taking into account the characteristics of its direction pattern of the capsule and propagation distance between the implanted capsule and on-body antenna, a cumulative distribution function (CDF) of the received SNR is evaluated. Then, simulation results related to the error ratio in the wireless channel are obtained. These results show that the frequencies of 611 MHz or lesser would be useful for the capsule endoscope applications from the view point of error rate performance. Further, we show that the use of antenna diversity brings additional gain to this application.

  15. Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.

    PubMed

    Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar

    2013-08-27

    Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to

  16. Person-centered endoscopy safety checklist: Development, implementation, and evaluation

    PubMed Central

    Dubois, Hanna; Schmidt, Peter T; Creutzfeldt, Johan; Bergenmar, Mia

    2017-01-01

    AIM To describe the development and implementation of a person-centered endoscopy safety checklist and to evaluate the effects of a “checklist intervention”. METHODS The checklist, based on previously published safety checklists, was developed and locally adapted, taking patient safety aspects into consideration and using a person-centered approach. This novel checklist was introduced to the staff of an endoscopy unit at a Stockholm University Hospital during half-day seminars and team training sessions. Structured observations of the endoscopy team’s performance were conducted before and after the introduction of the checklist. In addition, questionnaires focusing on patient participation, collaboration climate, and patient safety issues were collected from patients and staff. RESULTS A person-centered safety checklist was developed and introduced by a multi-professional group in the endoscopy unit. A statistically significant increase in accurate patient identity verification by the physicians was noted (from 0% at baseline to 87% after 10 mo, P < 0.001), and remained high among nurses (93% at baseline vs 96% after 10 mo, P = nonsignificant). Observations indicated that the professional staff made frequent attempts to use the checklist, but compliance was suboptimal: All items in the observed nurse-led “summaries” were included in 56% of these interactions, and physicians participated by directly facing the patient in 50% of the interactions. On the questionnaires administered to the staff, items regarding collaboration and the importance of patient participation were rated more highly after the introduction of the checklist, but this did not result in statistical significance (P = 0.07/P = 0.08). The patients rated almost all items as very high both before and after the introduction of the checklist; hence, no statistical difference was noted. CONCLUSION The intervention led to increased patient identity verification by physicians - a patient safety

  17. Cerebral Arterial Gas Embolism During Upper Endoscopy.

    PubMed

    Eoh, Eun J; Derrick, Bruce; Moon, Richard

    2015-09-15

    Arterial gas embolism can be caused by direct entry of gas into systemic arteries or indirectly by venous-to-arterial shunting. Although arterial gas embolism is rare, most documented cases are iatrogenic, resulting from the entry of gas during procedures that involve direct vascular cannulation or intracavitary air insufflation. Of the 18 identified case reports of air embolism during endoscopy, 11 cases describe findings of cerebral arterial gas embolism during upper endoscopy. Only 1 of these occurred during endoscopic balloon dilation of an esophageal stricture. We report a rare case of cerebral arterial gas embolism in a 64-year-old woman, which occurred during endoscopic dilation of an esophageal stricture and was subsequently treated with hyperbaric oxygen therapy. In this case report, we explore the possible etiologies, clinical workup, and therapeutic management of cerebral artery gas embolisms. Hyperbaric oxygen therapy is the treatment of choice for cerebral arterial gas embolism, with earlier treatments resulting in better outcomes.

  18. A wireless narrowband imaging chip for capsule endoscope.

    PubMed

    Lan-Rong Dung; Yin-Yi Wu

    2010-12-01

    This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.

  19. Positron radiography of ignition-relevant ICF capsules

    DOE PAGES

    Williams, G. J.; Chen, Hui; Field, J. E.; ...

    2017-12-11

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less

  20. Positron radiography of ignition-relevant ICF capsules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, G. J.; Chen, Hui; Field, J. E.

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less