Sample records for background flow cytometric

  1. Howard University Flow Cytometric Sorter For Research and Education

    DTIC Science & Technology

    2015-08-04

    Howard University s newly acquired Fluorescence Activated Cytometric Sorter (FACS) has been integrated into the new flow cytometric core facility...training (i.e. antibody panel setup and sample preparations). In the three months it has been active, six Howard University researchers have used the

  2. Development of an automated analysis system for data from flow cytometric intracellular cytokine staining assays from clinical vaccine trials

    PubMed Central

    Shulman, Nick; Bellew, Matthew; Snelling, George; Carter, Donald; Huang, Yunda; Li, Hongli; Self, Steven G.; McElrath, M. Juliana; De Rosa, Stephen C.

    2008-01-01

    Background Intracellular cytokine staining (ICS) by multiparameter flow cytometry is one of the primary methods for determining T cell immunogenicity in HIV-1 clinical vaccine trials. Data analysis requires considerable expertise and time. The amount of data is quickly increasing as more and larger trials are performed, and thus there is a critical need for high throughput methods of data analysis. Methods A web based flow cytometric analysis system, LabKey Flow, was developed for analyses of data from standardized ICS assays. A gating template was created manually in commercially-available flow cytometric analysis software. Using this template, the system automatically compensated and analyzed all data sets. Quality control queries were designed to identify potentially incorrect sample collections. Results Comparison of the semi-automated analysis performed by LabKey Flow and the manual analysis performed using FlowJo software demonstrated excellent concordance (concordance correlation coefficient >0.990). Manual inspection of the analyses performed by LabKey Flow for 8-color ICS data files from several clinical vaccine trials indicates that template gates can appropriately be used for most data sets. Conclusions The semi-automated LabKey Flow analysis system can analyze accurately large ICS data files. Routine use of the system does not require specialized expertise. This high-throughput analysis will provide great utility for rapid evaluation of complex multiparameter flow cytometric measurements collected from large clinical trials. PMID:18615598

  3. Flow cytometric analysis of extracellular vesicle subsets in plasma: impact of swarm by particles of non-interest.

    PubMed

    Libregts, S F W M; Arkesteijn, G J A; Németh, A; Nolte-'t Hoen, E N M; Wauben, M H M

    2018-05-20

    Essentials Extracellular vesicles (EVs) in biological fluids are promising biomarkers for disease. Fluorescence-based flow cytometric analysis is suitable to detect low abundant EV subsets. Particles of non-interest can induce false-positive light scatter and fluorescent signals. Interference of particles of non-interest can be monitored by analyzing serial dilutions. Background Extracellular vesicles (EVs) in plasma are increasingly being recognized as potential biomarkers. EV analysis for diagnostic purposes should be robust and should allow analysis of EV subsets with a wide range of abundance and in a large number of patient samples. Flow cytometry offers possibilities to meet these criteria, as it allows multiparameter analysis of individual EVs. However, analysis of plasma EVs is challenging, because of their size and heterogeneity, and the presence of other submicrometer-sized particles in plasma that could interfere with EV analysis. Objectives To explore whether fluorescence-based flow cytometric analysis of EV subsets is suitable when the EVs of interest are present in low abundance in a background of non-labeled or differently labeled EVs and particles. Methods Fluorescently labeled EVs of interest were spiked at different ratios in full plasma, purified plasma components, or (non-)fluorescent polystyrene beads, and subsequently analyzed by flow cytometry with fluorescence threshold triggering. Results We found that light scatter detection of low-abundance or rare EV subsets during fluorescence threshold triggering was severely affected by particles of non-interest, owing to coincidence and swarming. Importantly, we show that interfering particles labeled with different fluorophores induced false-positive fluorescent signals on the particles of interest. These unwanted effects could only be discerned and controlled by performing serial dilutions and analyzing light scatter and fluorescence parameters. Conclusions We demonstrate how particles of non

  4. Flow cytometric immunofluorescence of rat anterior pituitary cells

    NASA Technical Reports Server (NTRS)

    Hatfield, J. Michael; Hymer, W. C.

    1985-01-01

    A flow cytometric immunofluorescence technique was developed for the quantification of growth hormone, prolactin, and luteinizing hormone producing cells. The procedure is based on indirect-immunofluorescence of intracellular hormone using an EPICS V cell sorter and can objectively count 50,000 cells in about 3 minutes. It can be used to study the dynamics of pituitary cell populations under various physiological and pharmacological conditions.

  5. Novel nuclei isolation buffer for flow cytometric genome size estimation of Zingiberaceae: a comparison with common isolation buffers

    PubMed Central

    Sadhu, Abhishek; Bhadra, Sreetama; Bandyopadhyay, Maumita

    2016-01-01

    Background and Aims Cytological parameters such as chromosome numbers and genome sizes of plants are used routinely for studying evolutionary aspects of polyploid plants. Members of Zingiberaceae show a wide range of inter- and intrageneric variation in their reproductive habits and ploidy levels. Conventional cytological study in this group of plants is severely hampered by the presence of diverse secondary metabolites, which also affect their genome size estimation using flow cytometry. None of the several nuclei isolation buffers used in flow cytometry could be used very successfully for members of Zingiberaceae to isolate good quality nuclei from both shoot and root tissues. Methods The competency of eight nuclei isolation buffers was compared with a newly formulated buffer, MB01, in six different genera of Zingiberaceae based on the fluorescence intensity of propidium iodide-stained nuclei using flow cytometric parameters, namely coefficient of variation of the G0/G1 peak, debris factor and nuclei yield factor. Isolated nuclei were studied using fluorescence microscopy and bio-scanning electron microscopy to analyse stain–nuclei interaction and nuclei topology, respectively. Genome contents of 21 species belonging to these six genera were determined using MB01. Key Results Flow cytometric parameters showed significant differences among the analysed buffers. MB01 exhibited the best combination of analysed parameters; photomicrographs obtained from fluorescence and electron microscopy supported the superiority of MB01 buffer over other buffers. Among the 21 species studied, nuclear DNA contents of 14 species are reported for the first time. Conclusions Results of the present study substantiate the enhanced efficacy of MB01, compared to other buffers tested, in the generation of acceptable cytograms from all species of Zingiberaceae studied. Our study facilitates new ways of sample preparation for further flow cytometric analysis of genome size of other members

  6. Flow cytometric characterization of cerebrospinal fluid cells.

    PubMed

    de Graaf, Marieke T; de Jongste, Arjen H C; Kraan, Jaco; Boonstra, Joke G; Sillevis Smitt, Peter A E; Gratama, Jan W

    2011-09-01

    Flow cytometry facilitates the detection of a large spectrum of cellular characteristics on a per cell basis, determination of absolute cell numbers and detection of rare events with high sensitivity and specificity. White blood cell (WBC) counts in cerebrospinal fluid (CSF) are important for the diagnosis of many neurological disorders. WBC counting and differential can be performed by microscopy, hematology analyzers, or flow cytometry. Flow cytometry of CSF is increasingly being considered as the method of choice in patients suspected of leptomeningeal localization of hematological malignancies. Additionally, in several neuroinflammatory diseases such as multiple sclerosis and paraneoplastic neurological syndromes, flow cytometry is commonly performed to obtain insight into the immunopathogenesis of these diseases. Technically, the low cellularity of CSF samples, combined with the rapidly declining WBC viability, makes CSF flow cytometry challenging. Comparison of flow cytometry with microscopic and molecular techniques shows that each technique has its own advantages and is ideally combined. We expect that increasing the number of flow cytometric parameters that can be simultaneously studied within one sample, will further refine the information on CSF cell subsets in low-cellular CSF samples and enable to define cell populations more accurately. Copyright © 2011 International Clinical Cytometry Society.

  7. Air sampling to assess potential generation of aerosolized viable bacteria during flow cytometric analysis of unfixed bacterial suspensions

    PubMed Central

    Carson, Christine F; Inglis, Timothy JJ

    2018-01-01

    This study investigated aerosolized viable bacteria in a university research laboratory during operation of an acoustic-assisted flow cytometer for antimicrobial susceptibility testing by sampling room air before, during and after flow cytometer use. The aim was to assess the risk associated with use of an acoustic-assisted flow cytometer analyzing unfixed bacterial suspensions. Air sampling in a nearby clinical laboratory was conducted during the same period to provide context for the existing background of microorganisms that would be detected in the air. The three species of bacteria undergoing analysis by flow cytometer in the research laboratory were Klebsiella pneumoniae, Burkholderia thailandensis and Streptococcus pneumoniae. None of these was detected from multiple 1000 L air samples acquired in the research laboratory environment. The main cultured bacteria in both locations were skin commensal and environmental bacteria, presumed to have been disturbed or dispersed in laboratory air by personnel movements during routine laboratory activities. The concentrations of bacteria detected in research laboratory air samples were reduced after interventional cleaning measures were introduced and were lower than those in the diagnostic clinical microbiology laboratory. We conclude that our flow cytometric analyses of unfixed suspensions of K. pneumoniae, B. thailandensis and S. pneumoniae do not pose a risk to cytometer operators or other personnel in the laboratory but caution against extrapolation of our results to other bacteria and/or different flow cytometric experimental procedures. PMID:29608197

  8. Multivariate analysis of flow cytometric data using decision trees.

    PubMed

    Simon, Svenja; Guthke, Reinhard; Kamradt, Thomas; Frey, Oliver

    2012-01-01

    Characterization of the response of the host immune system is important in understanding the bidirectional interactions between the host and microbial pathogens. For research on the host site, flow cytometry has become one of the major tools in immunology. Advances in technology and reagents allow now the simultaneous assessment of multiple markers on a single cell level generating multidimensional data sets that require multivariate statistical analysis. We explored the explanatory power of the supervised machine learning method called "induction of decision trees" in flow cytometric data. In order to examine whether the production of a certain cytokine is depended on other cytokines, datasets from intracellular staining for six cytokines with complex patterns of co-expression were analyzed by induction of decision trees. After weighting the data according to their class probabilities, we created a total of 13,392 different decision trees for each given cytokine with different parameter settings. For a more realistic estimation of the decision trees' quality, we used stratified fivefold cross validation and chose the "best" tree according to a combination of different quality criteria. While some of the decision trees reflected previously known co-expression patterns, we found that the expression of some cytokines was not only dependent on the co-expression of others per se, but was also dependent on the intensity of expression. Thus, for the first time we successfully used induction of decision trees for the analysis of high dimensional flow cytometric data and demonstrated the feasibility of this method to reveal structural patterns in such data sets.

  9. Assessment of amphotericin B susceptibility in Leishmania infantum promastigotes by flow cytometric membrane potential assay.

    PubMed

    Azas, N; Di Giorgio, C; Delmas, F; Gasquet, M; Timon-David, P

    1997-06-01

    Flow cytometry was used for measuring the effects of amphotericin B on the membrane of Leishmania infantum strains. The technique was adapted from the rapid flow cytometric membrane potential assay developed by Ordonez and Wehman (Cytometry 22:154-157, 1995) for evaluating antibiotic-susceptibility of Candida species. The study consisted of measuring membrane potential changes induced by amphotericin B in 3 initial strains and 12 laboratory-generated variants adapted to grow with amphotericin B. Results showed that, after 3 h of incubation, amphotericin B induced a dose-related decrease of membrane potential that reached its maximal level at the same concentrations that inhibited parasite growth. These results suggest that the flow cytometric membrane potential assay could be used to assess the susceptibility of Leishmania promastigotes to amphotericin B.

  10. Recommendations for the evaluation of specimen stability for flow cytometric testing during drug development.

    PubMed

    Brown, Lynette; Green, Cherie L; Jones, Nicholas; Stewart, Jennifer J; Fraser, Stephanie; Howell, Kathy; Xu, Yuanxin; Hill, Carla G; Wiwi, Christopher A; White, Wendy I; O'Brien, Peter J; Litwin, Virginia

    2015-03-01

    The objective of this manuscript is to present an approach for evaluating specimen stability for flow cytometric methods used during drug development. While this approach specifically addresses stability assessment for assays to be used in clinical trials with centralized testing facilities, the concepts can be applied to any stability assessment for flow cytometric methods. The proposed approach is implemented during assay development and optimization, and includes suggestions for designing a stability assessment plan, data evaluation and acceptance criteria. Given that no single solution will be applicable in all scenarios, this manuscript offers the reader a roadmap for stability assessment and is intended to guide the investigator during both the method development phase and in the experimental design of the validation plan. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Flow Cytometric Analysis of Hepatocytes from Normal, PFDA, and PH/DEN/ PB-Treated Rats

    DTIC Science & Technology

    1989-12-31

    SUB-GROUP’ Perfluorodecanoic acid ( PFDA ); hepatocarcinogenesis; preneoplastic lesions; flow cytometry; imunotoxicitYyc3 1%&STRACT (Continue on...effects of perfluorodecanoic acid ( PFDA ). Flow cytometric evaluation of hepatocytes from PEDA-treated rats revealed an increase in size and granularity...was designed to generate preliminary information regarding the toxic and potential carcinogenic effects of perfluorodecanoic acid ( PFDA ) on rat

  12. Flow cytometric analyses of CD34+ cells with inclusion of internal positive controls.

    PubMed

    Gutensohn, Kai; Jessen, Maria; Ketels, Andrea; Gramatzki, Martin; Humpe, Andreas

    2012-02-01

    Flow cytometric measurement of CD34+ events is used to ensure the quality of human progenitor cell grafts. This study was conducted to evaluate whether the spiking of routine samples from peripheral blood and apheresis products with CD34+ positive controls is feasible. A total of 42 samples from 32 patients and one healthy donor were stained in duplicate for CD34+ cells. Before flow cytometric analysis, one tube was spiked with stabilized CD34+ cells at a defined concentration. Median numbers of viable CD34+ cells/µL did not differ between unspiked and spiked tubes (median 37, range 0-714; and median 34, range 0-719, respectively). The 95% confidence interval (CI) of the mean showed a broad overlap between these samples (41.9-119.1 and 41.4-119.3, respectively). In addition, the 95% CI of the mean for CD45+ cells/µL overlapped broadly and median numbers did not differ. Median viability of all CD45+ cells was significantly lower in the spiked tubes (96.75, range 64-98.8 vs. 99.25, range 97.5-99.8) with no overlap of the 95% CI of the mean viability. The results of this study show that spiking of routine samples with internal positive controls does not affect CD34+ cell analyses, but does support the reliability of important clinical data. The inclusion of positive controls is expedient for laboratories that perform analyses with low CD34+ numbers and laboratories that use different flow cytometric analyzers and may also become a requirement to meet statutory regulations. © 2012 American Association of Blood Banks.

  13. Flow cytometric measurement of total DNA and incorporated halodeoxyuridine

    DOEpatents

    Dolbeare, Frank A.; Gray, Joe W.

    1986-01-01

    A method for the simultaneous flow cytometric measurement of the total DNA content and the level of DNA synthesis in normal and malignant cells is disclosed. The sensitivity of the method allows a study of cell cycle traverse rates for large scale cell populations as well as single cell measurements. A DNA stain such as propidium iodide is used as the probe for the measurement of total DNA content and a monoclonal antibody reactive with a DNA precursor such as bromodeoxyuridine (BrdU) is used as a probe for the measurement of BrdU uptake by the cells as a measure of DNA synthesis.

  14. Medical Devices; Hematology and Pathology Devices; Classification of the Flow Cytometric Test System for Hematopoietic Neoplasms. Final order.

    PubMed

    2017-12-27

    The Food and Drug Administration (FDA or we) is classifying the flow cytometric test system for hematopoietic neoplasms into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the flow cytometric test system for hematopoietic neoplasms' classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  15. Flow cytometric analysis of microbial contamination in food industry technological lines--initial study.

    PubMed

    Józwa, Wojciech; Czaczyk, Katarzyna

    2012-04-02

    Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.

  16. Flow cytometric measurement of total DNA and incorporated halodeoxyuridine

    DOEpatents

    Dolbeare, Frank A.; Gray, Joe W.

    1988-01-01

    A method for the simultaneous flow cytometric measurement of the total DNA content and the level of DNA synthesis in normal and malignant cells is disclosed. The sensitivity of the method allows a study of cell cycle traverse rates for large scale cell populations as well as single cell measurements. A DNA stain such as propidium iodide or Hoechst 33258 is used as the probe for the measurement of total DNA content and a monoclonal antibody reactive with a DNA precursor such as halodeoxy-uridine (HdU), more specifically bromodeoxyuridine (BrdU) is used as a probe for the measurement of HdU or BrdU uptake by the cells as a measure of DNA synthesis.

  17. Clinical flow cytometric screening of SAP and XIAP expression accurately identifies patients with SH2D1A and XIAP/BIRC4 mutations.

    PubMed

    Gifford, Carrie E; Weingartner, Elizabeth; Villanueva, Joyce; Johnson, Judith; Zhang, Kejian; Filipovich, Alexandra H; Bleesing, Jack J; Marsh, Rebecca A

    2014-07-01

    X-linked lymphoproliferative disease is caused by mutations in two genes, SH2D1A and XIAP/BIRC4. Flow cytometric methods have been developed to detect the gene products, SAP and XIAP. However, there is no literature describing the accuracy of flow cytometric screening performed in a clinical lab setting. We reviewed the clinical flow cytometric testing results for 656 SAP and 586 XIAP samples tested during a 3-year period. Genetic testing was clinically performed as directed by the managing physician in 137 SAP (21%) and 115 XIAP (20%) samples. We included these samples for analyses of flow cytometric test accuracy. SH2D1A mutations were detected in 15/137 samples. SAP expression was low in 13/15 (sensitivity 87%, CI 61-97%). Of the 122 samples with normal sequencing, SAP was normal in 109 (specificity 89%, CI 82-94%). The positive predictive values (PPVs) and the negative predictive values (NPVs) were 50% and 98%, respectively. XIAP/BIRC4 mutations were detected in 19/115 samples. XIAP expression was low in 18/19 (sensitivity 95%, CI 73-100%). Of the 96 samples with normal sequencing, 59 had normal XIAP expression (specificity 61%, CI 51-71%). The PPVs and NPVs were 33% and 98%, respectively. Receiver-operating characteristic analysis was able to improve the specificity to 75%. Clinical flow cytometric screening tests for SAP and XIAP deficiencies offer good sensitivity and specificity for detecting genetic mutations, and are characterized by high NPVs. We recommend these tests for patients suspected of having X-linked lymphoproliferative disease type 1 (XLP1) or XLP2. © 2014 Clinical Cytometry Society.

  18. Quantification of circulating mature endothelial cells using a whole blood four-color flow cytometric assay.

    PubMed

    Jacques, Nathalie; Vimond, Nadege; Conforti, Rosa; Griscelli, Franck; Lecluse, Yann; Laplanche, Agnes; Malka, David; Vielh, Philippe; Farace, Françoise

    2008-09-15

    Circulating endothelial cells (CEC) are currently proposed as a potential biomarker for measuring the impact of anti-angiogenic treatments in cancer. However, the lack of consensus on the appropriate method of CEC measurement has led to conflicting data in cancer patients. A validated assay adapted for evaluating the clinical utility of CEC in large cohorts of patients undergoing anti-angiogenic treatments is needed. We developed a four-color flow cytometric assay to measure CEC as CD31(+), CD146(+), CD45(-), 7-amino-actinomycin-D (7AAD)(-) events in whole blood. The distinctive features of the assay are: (1) staining of 1 ml whole blood, (2) use of a whole blood IgPE control to measure accurately background noise, (3) accumulation of a large number of events (almost 5 10(6)) to ensure statistical analysis, and (4) use of 10 microm fluorescent microbeads to evaluate the event size. Assay reproducibility was determined in duplicate aliquots of samples drawn from 20 metastatic cancer patients. Assay linearity was tested by spiking whole blood with low numbers of HUVEC. Five-color flow cytometric experiments with CD144 were performed to confirm the endothelial origin of the cells. CEC were measured in 20 healthy individuals and 125 patients with metastatic cancer. Reproducibility was good between duplicate aliquots (r(2)=0.948, mean difference between duplicates of 0.86 CEC/ml). Detected HUVEC correlated with spiked HUVEC (r(2)=0.916, mean recovery of 100.3%). Co-staining of CD31, CD146 and CD144 confirmed the endothelial nature of cells identified as CEC. Median CEC levels were 6.5/ml (range, 0-15) in healthy individuals and 15.0/ml (range, 0-179) in patients with metastatic carcinoma (p<0.001). The assay proposed here allows reproducible and sensitive measurement of CEC by flow cytometry and could help evaluate CEC as biomarkers of anti-angiogenic therapies in large cohorts of patients.

  19. Rapid Detection and Enumeration of Giardia lamblia Cysts in Water Samples by Immunomagnetic Separation and Flow Cytometric Analysis ▿ †

    PubMed Central

    Keserue, Hans-Anton; Füchslin, Hans Peter; Egli, Thomas

    2011-01-01

    Giardia lamblia is an important waterborne pathogen and is among the most common intestinal parasites of humans worldwide. Its fecal-oral transmission leads to the presence of cysts of this pathogen in the environment, and so far, quantitative rapid screening methods are not available for various matrices, such as surface waters, wastewater, or food. Thus, it is necessary to establish methods that enable reliable rapid detection of a single cyst in 10 to 100 liters of drinking water. Conventional detection relies on cyst concentration, isolation, and confirmation by immunofluorescence microscopy (IFM), resulting in low recoveries and high detection limits. Many different immunomagnetic separation (IMS) procedures have been developed for separation and cyst purification, so far with variable but high losses of cysts. A method was developed that requires less than 100 min and consists of filtration, resuspension, IMS, and flow cytometric (FCM) detection. MACS MicroBeads were used for IMS, and a reliable flow cytometric detection approach was established employing 3 different parameters for discrimination from background signals, i.e., green and red fluorescence (resulting from the distinct pattern emitted by the fluorescein dye) and sideward scatter for size discrimination. With spiked samples, recoveries exceeding 90% were obtained, and false-positive results were never encountered for negative samples. Additionally, the method was applicable to naturally occurring cysts in wastewater and has the potential to be automated. PMID:21685159

  20. The cytometric future: it ain't necessarily flow!

    PubMed

    Shapiro, Howard M

    2011-01-01

    Initial approaches to cytometry for classifying and characterizing cells were based on microscopy; it was necessary to collect relatively high-resolution images of cells because only a few specific reagents usable for cell identification were available. Although flow cytometry, now the dominant cytometric technology, typically utilizes lenses similar to microscope lenses for light collection, improved, more quantitative reagents allow the necessary information to be acquired in the form of whole-cell measurements of the intensities of light transmission, scattering, and/or fluorescence.Much of the cost and complexity of both automated microscopes and flow cytometers arises from the necessity for them to measure one cell at a time. Recent developments in digital camera technology now offer an alternative in which one or more low-magnification, low-resolution images are made of a wide field containing many cells, using inexpensive light-emitting diodes (LEDs) for illumination. Minimalist widefield imaging cytometers can provide a smaller, less complex, and substantially less expensive alternative to flow cytometry, critical in systems intended for in resource-poor areas. Minimalism is, likewise, a good philosophy in developing instrumentation and methodology for both clinical and large-scale research use; it simplifies quality assurance and compliance with regulatory requirements, as well as reduces capital outlays, material costs, and personnel training requirements. Also, importantly, it yields "greener" technology.

  1. Vortex-dislodged cells from bone marrow trephine biopsy yield satisfactory results for flow cytometric immunophenotyping.

    PubMed

    Bommannan, K; Sachdeva, M U S; Gupta, M; Bose, P; Kumar, N; Sharma, P; Naseem, S; Ahluwalia, J; Das, R; Varma, N

    2016-10-01

    A good bone marrow (BM) sample is essential in evaluating many hematologic disorders. An unsuccessful BM aspiration (BMA) procedure precludes a successful flow cytometric immunophenotyping (FCI) in most hematologic malignancies. Apart from FCI, most ancillary diagnostic techniques in hematology are less informative. We describe the feasibility of FCI in vortex-dislodged cell preparation obtained from unfixed trephine biopsy (TB) specimens. In pancytopenic patients and dry tap cases, routine diagnostic BMA and TB samples were complemented by additional trephine biopsies. These supplementary cores were immediately transferred into sterile tubes filled with phosphate-buffered saline, vortexed, and centrifuged. The cell pellet obtained was used for flow cytometric immunophenotyping. Of 7955 BMAs performed in 42 months, 34 dry tap cases were eligible for the study. Vortexing rendered a cell pellet in 94% of the cases (32 of 34), and FCI rendered a rapid diagnosis in 100% of the cases (32 of 32) where cell pellets were available. We describe an efficient procedure which could be effectively utilized in resource-limited centers and reduce the frequency of repeat BMA procedures. © 2016 John Wiley & Sons Ltd.

  2. Flow cytometric techniques for detection of candidate cancer stem cell subpopulations in canine tumour models.

    PubMed

    Blacking, T M; Waterfall, M; Samuel, K; Argyle, D J

    2012-12-01

    The cancer stem cell (CSC) hypothesis proposes that tumour growth is maintained by a distinct subpopulation of 'CSC'. This study applied flow cytometric methods, reported to detect CSC in both primary and cultured cancer cells of other species, to identify candidate canine subpopulations. Cell lines representing diverse canine malignancies, and cells derived from spontaneous canine tumours, were evaluated for expression of stem cell-associated surface markers (CD34, CD44, CD117 and CD133) and functional properties [Hoecsht 33342 efflux, aldehyde dehydrogenase (ALDH) activity]. No discrete marker-defined subsets were identified within established cell lines; cells derived directly from spontaneous tumours demonstrated more heterogeneity, although this diminished upon in vitro culture. Functional assays produced variable results, suggesting context-dependency. Flow cytometric methods may be adopted to identify putative canine CSC. Whilst cell lines are valuable in assay development, primary cells may provide a more rewarding model for studying tumour heterogeneity in the context of CSC. However, it will be essential to fully characterize any candidate subpopulations to ensure that they meet CSC criteria. © 2011 Blackwell Publishing Ltd.

  3. HLA-targeted flow cytometric sorting of blood cells allows separation of pure and viable microchimeric cell populations.

    PubMed

    Drabbels, Jos J M; van de Keur, Carin; Kemps, Berit M; Mulder, Arend; Scherjon, Sicco A; Claas, Frans H J; Eikmans, Michael

    2011-11-10

    Microchimerism is defined by the presence of low levels of nonhost cells in a person. We developed a reliable method for separating viable microchimeric cells from the host environment. For flow cytometric cell sorting, HLA antigens were targeted with human monoclonal HLA antibodies (mAbs). Optimal separation of microchimeric cells (present at a proportion as low as 0.01% in artificial mixtures) was obtained with 2 different HLA mAbs, one targeting the chimeric cells and the other the background cells. To verify purity of separated cell populations, flow-sorted fractions of 1000 cells were processed for DNA analysis by HLA-allele-specific and Y-chromosome-directed real-time quantitative PCR assays. After sorting, PCR signals of chimeric DNA markers in the positive fractions were significantly enhanced compared with those in the presort samples, and they were similar to those in 100% chimeric control samples. Next, we demonstrate applicability of HLA-targeted FACS sorting after pregnancy by separating chimeric maternal cells from child umbilical cord mononuclear cells. Targeting allelic differences with anti-HLA mAbs with FACS sorting allows maximal enrichment of viable microchimeric cells from a background cell population. The current methodology enables reliable microchimeric cell detection and separation in clinical specimens.

  4. Multivariate data analysis methods for the interpretation of microbial flow cytometric data.

    PubMed

    Davey, Hazel M; Davey, Christopher L

    2011-01-01

    Flow cytometry is an important technique in cell biology and immunology and has been applied by many groups to the analysis of microorganisms. This has been made possible by developments in hardware that is now sensitive enough to be used routinely for analysis of microbes. However, in contrast to advances in the technology that underpin flow cytometry, there has not been concomitant progress in the software tools required to analyse, display and disseminate the data and manual analysis, of individual samples remains a limiting aspect of the technology. We present two new data sets that illustrate common applications of flow cytometry in microbiology and demonstrate the application of manual data analysis, automated visualisation (including the first description of a new piece of software we are developing to facilitate this), genetic programming, principal components analysis and artificial neural nets to these data. The data analysis methods described here are equally applicable to flow cytometric applications with other cell types.

  5. Novel flow cytometric method for the detection of podocalyxin-positive elements in urine of patients with glomerulonephritides - first promising results.

    PubMed

    Habara, P; Marečková, H; Malíčková, K; Potyšová, Z; Hrušková, Z; Zima, T; Tesař, V

    2012-01-01

    Glomerulonephritides together create a heterogenic group of supposedly immunologically mediated diseases of glomeruli. They still belong among the most frequent causes of chronic renal failure. Detection of podocytes in urine might serve as an important marker of glomerulonephritides activity. The aim of this study was to develop a novel flow cytometric method for the detection of podocyte fragments and podocytes in urine and assess its possible use in clinical practice. We placed emphasis on the improvement of pre-analytic phase. To suppress the autofluorescence of the background, blocking solutions and magnetic separation were used. An additional surface marker CD10 (nephrilysin) was used together with routinely used podocalyxin (PCX) in order to achieve better identification of podocytes. Based on the surface marker expression, three different element types were identified in the urine samples: PCX+/CD10+ elements (EL) (supposedly podocytes), PCX-/CD10+ EL (supposedly parietal epithelial cells) and PCX+ EL. We examined a total of 36 patients who underwent renal biopsy (non-glomerular nephropathy, MGN, FSGS, IgAN, AAV and MPGN) and 27 healthy controls. Negative results were found in non-glomerular nephropathy and in MGN. In patients with FSGS and IgAN, the levels of urine elements were slightly increased. The highest levels of all elements were found in AAV and MPGN. Our first results suggest that flow cytometric detection may distinguish between glomerular and nonglomerular diseases and that the levels of urine elements might correlate with the degree of glomerular destruction.

  6. Flow cytometric and radioisotopic determinations of platelet survival time in normal cats and feline leukemia virus-infected cats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, R.M.; Boyce, J.T.; Kociba, G.J.

    This study demonstrates the potential usefulness of a flow cytometric technique to measure platelet survival time in cats utilizing autologous platelets labeled in vitro with fluorescein isothiocyanate (FITC). When compared with a 51Cr method, no significant differences in estimated survival times were found. Both the 51Cr and FITC-labeling procedures induced similar changes in platelet shape and collagen-induced aggregation. Platelets labeled with FITC had significantly greater volumes compared with those of glutaraldehyde-fixed platelets. These changes were primarily related to the platelet centrifugation and washing procedures rather than the labels themselves. This novel technique potentially has wide applicability to cell circulation timemore » studies as flow cytometry equipment becomes more readily available. Problems with the technique are discussed. In a preliminary study of the platelet survival time in feline leukemia virus (FeLV)-infected cats, two of three cats had significantly reduced survival times using both flow cytometric and radioisotopic methods. These data suggest increased platelet turnover in FeLV-infected cats.« less

  7. Flow cytometric determination of quantitative immunophenotypes

    NASA Astrophysics Data System (ADS)

    Redelman, Douglas; Ensign, Wayne; Roberts, Don

    2001-05-01

    Immunofluorescent flow cytometric analysis of peripheral blood leucocytes is most commonly used to identify and enumerate cells defined by one or more clusters of differentiation (CD) antigens. Although less widely employed, quantitative tests that measure the amounts of CD antigens expressed per cell are used in some situations such as the characterization of lymphomas and leukocytes or the measurement of CD38 on CD3plu8pluT cells in HIV infected individuals. The CD antigens used to identify leukocyte populations are functionally important molecules and it is known that under- or over-expression of some CD antigens can affect cellular responses. For example, high or low expression of CD19 on B cells is associated with autoimmune conditions or depressed antibody responses, respectively. In the current studies, the quantitative expression of CD antigens on T cells, B cells and monocytes was determined in a group of age and sex-matched Marines at several times before and after training exercises. There was substantial variation among these individuals in the quantitative expression of CD antigens and in the number of cells in various populations. However, there was relatively little variation within individuals during the two months they were examined. Thus, the number of cells in leukocyte sub-populations and the amount of CD antigens expressed per cell appear to comprise a characteristic quantitative immunophenotype.

  8. A flow cytometric approach to the study of crustacean cellular immunity

    USGS Publications Warehouse

    Cardenas, W.; Jenkins, J.A.; Dankert, J.R.

    2000-01-01

    Responses of hemocytes from the crayfish Procambarus zonangulus to stimulation by fungal cell walls (Zymosan A) were measured by flow cytometry. Changes in hemocyte physical characteristics were assessed flow cytometrically using forward- and sidescatter light parameters, and viability was measured by two-color fluorescent staining with calcein-AM and ethidium homodimer 1. The main effects of zymosan A on crayfish hemocytes were reduction in cell size and viability compared to control mixtures (hemocytes in buffer only). Adding diethyldithiocarbamic acid, an inhibitor of phenoloxidase, to hemocyte to zymosan mixtures delayed the time course of cell size reduction and cell death compared to zymosan-positive controls. The inclusion of trypsin inhibitor in reaction mixtures further delayed the reduction in hemocyte size and cell death, thereby indicating that a proteolytic cascade, along with prophenoloxidase activation, played a key role in generating signal molecules which mediate these cellular responses. In addition to traditional methods such as microscopy and protein chemistry, flow cytometry can provide a simple, reproducible, and sensitve method for evaluating invertebrate hemocyte responses to immunological stimuli.

  9. Viability and membrane integrity of spermatozoa after dilution and flow cytometric sorting in the presence or absence of seminal plasma.

    PubMed

    Maxwell, W M; Welch, G R; Johnson, L A

    1996-01-01

    Boar, bull and ram spermatozoa were examined after staining with the DNA-permeant Hoechst 33342 fluorochrome and flow cytometric sorting in the presence or absence of seminal plasma. Spermatozoa were assessed for viability with flow cytometry using the live cell nucleic acid stain SYBR-14 and propidium iodide (PI), and for membrane integrity using fluorescein isothiocyanate-conjugated Pisum sativum (FITC-PSA) and PI; motility and acrosome integrity were estimated by microscopy. Flow cytometric sorting was compared with pipette dilution of boar and bull spermatozoa into: (1) medium [boar: Test buffer containing 2% yolk (TY) or Beltsville thawing solution (BTS); bull: TY or HEPES buffer containing 0.1% bovine serum albumin (HEPES-BSA)] with or without 10% (v/v) seminal plasma; or (2) an empty tube containing no medium. Sorted spermatozoa were either not centrifuged or centrifuged before assessment during a 4-h holding period. The viability, motility and membrane integrity of boar, bull and ram spermatozoa centrifuged after sorting were also examined when seminal plasma was present or absent from the staining extender and/or the TY collection medium. The results indicate that the viability and membrane integrity of spermatozoa in vitro would be improved if: (1) seminal plasma (10%) was routinely included in the BTS and HEPES-BSA staining extenders for boar spermatozoa and ram spermatozoa, respectively, when used in preparation for flow cytometric sorting; and (2) 10% and 50% seminal plasma were included in the TY collection medium for boar or bull spermatozoa and ram spermatozoa respectively.

  10. Flow Cytometric Quantification of Peripheral Blood Cell β-Adrenergic Receptor Density and Urinary Endothelial Cell-Derived Microparticles in Pulmonary Arterial Hypertension.

    PubMed

    Rose, Jonathan A; Wanner, Nicholas; Cheong, Hoi I; Queisser, Kimberly; Barrett, Patrick; Park, Margaret; Hite, Corrine; Naga Prasad, Sathyamangla V; Erzurum, Serpil; Asosingh, Kewal

    2016-01-01

    Pulmonary arterial hypertension (PAH) is a heterogeneous disease characterized by severe angiogenic remodeling of the pulmonary artery wall and right ventricular hypertrophy. Thus, there is an increasing need for novel biomarkers to dissect disease heterogeneity, and predict treatment response. Although β-adrenergic receptor (βAR) dysfunction is well documented in left heart disease while endothelial cell-derived microparticles (Ec-MPs) are established biomarkers of angiogenic remodeling, methods for easy large clinical cohort analysis of these biomarkers are currently absent. Here we describe flow cytometric methods for quantification of βAR density on circulating white blood cells (WBC) and Ec-MPs in urine samples that can be used as potential biomarkers of right heart failure in PAH. Biotinylated β-blocker alprenolol was synthesized and validated as a βAR specific probe that was combined with immunophenotyping to quantify βAR density in circulating WBC subsets. Ec-MPs obtained from urine samples were stained for annexin-V and CD144, and analyzed by a micro flow cytometer. Flow cytometric detection of alprenolol showed that βAR density was decreased in most WBC subsets in PAH samples compared to healthy controls. Ec-MPs in urine was increased in PAH compared to controls. Furthermore, there was a direct correlation between Ec-MPs and Tricuspid annular plane systolic excursion (TAPSE) in PAH patients. Therefore, flow cytometric quantification of peripheral blood cell βAR density and urinary Ec-MPs may be useful as potential biomarkers of right ventricular function in PAH.

  11. Flow Cytometric Quantification of Peripheral Blood Cell β-Adrenergic Receptor Density and Urinary Endothelial Cell-Derived Microparticles in Pulmonary Arterial Hypertension

    PubMed Central

    Rose, Jonathan A.; Wanner, Nicholas; Cheong, Hoi I.; Queisser, Kimberly; Barrett, Patrick; Park, Margaret; Hite, Corrine; Naga Prasad, Sathyamangla V.; Erzurum, Serpil; Asosingh, Kewal

    2016-01-01

    Pulmonary arterial hypertension (PAH) is a heterogeneous disease characterized by severe angiogenic remodeling of the pulmonary artery wall and right ventricular hypertrophy. Thus, there is an increasing need for novel biomarkers to dissect disease heterogeneity, and predict treatment response. Although β-adrenergic receptor (βAR) dysfunction is well documented in left heart disease while endothelial cell-derived microparticles (Ec-MPs) are established biomarkers of angiogenic remodeling, methods for easy large clinical cohort analysis of these biomarkers are currently absent. Here we describe flow cytometric methods for quantification of βAR density on circulating white blood cells (WBC) and Ec-MPs in urine samples that can be used as potential biomarkers of right heart failure in PAH. Biotinylated β-blocker alprenolol was synthesized and validated as a βAR specific probe that was combined with immunophenotyping to quantify βAR density in circulating WBC subsets. Ec-MPs obtained from urine samples were stained for annexin-V and CD144, and analyzed by a micro flow cytometer. Flow cytometric detection of alprenolol showed that βAR density was decreased in most WBC subsets in PAH samples compared to healthy controls. Ec-MPs in urine was increased in PAH compared to controls. Furthermore, there was a direct correlation between Ec-MPs and Tricuspid annular plane systolic excursion (TAPSE) in PAH patients. Therefore, flow cytometric quantification of peripheral blood cell βAR density and urinary Ec-MPs may be useful as potential biomarkers of right ventricular function in PAH. PMID:27270458

  12. Novel flow cytometric analysis of the progress and route of internalization of a monoclonal anti-carcinoembryonic antigen (CEA) antibody.

    PubMed

    Ford, C H; Tsaltas, G C; Osborne, P A; Addetia, K

    1996-03-01

    A flow cytometric method of studying the internalization of a monoclonal antibody (Mab) directed against carcinoembryonic antigen (CEA) has been compared with Western blotting, using three human colonic cancer cell lines which express varying amounts of the target antigen. Cell samples incubated for increasing time intervals with fluoresceinated or unlabelled Mab were analyzed using flow cytometry or polyacrylamide gel electrophoresis and Western blotting. SDS/PAGE analysis of cytosolic and membrane components of solubilized cells from the cell lines provided evidence of non-degraded internalized anti-CEA Mab throughout seven half hour intervals, starting at 5 min. Internalized anti-CEA was detected in the case of high CEA expressing cell lines (LS174T, SKCO1). Very similar results were obtained with an anti-fluorescein flow cytometric assay. Given that these two methods consistently provided comparable results, use of flow cytometry for the detection of internalized antibody is suggested as a rapid alternative to most currently used methods for assessing antibody internalization. The question of the endocytic route followed by CEA-anti-CEA complexes was addressed by using hypertonic medium to block clathrin mediated endocytosis.

  13. Novel nuclei isolation buffer for flow cytometric genome size estimation of Zingiberaceae: a comparison with common isolation buffers.

    PubMed

    Sadhu, Abhishek; Bhadra, Sreetama; Bandyopadhyay, Maumita

    2016-11-01

    Cytological parameters such as chromosome numbers and genome sizes of plants are used routinely for studying evolutionary aspects of polyploid plants. Members of Zingiberaceae show a wide range of inter- and intrageneric variation in their reproductive habits and ploidy levels. Conventional cytological study in this group of plants is severely hampered by the presence of diverse secondary metabolites, which also affect their genome size estimation using flow cytometry. None of the several nuclei isolation buffers used in flow cytometry could be used very successfully for members of Zingiberaceae to isolate good quality nuclei from both shoot and root tissues. The competency of eight nuclei isolation buffers was compared with a newly formulated buffer, MB01, in six different genera of Zingiberaceae based on the fluorescence intensity of propidium iodide-stained nuclei using flow cytometric parameters, namely coefficient of variation of the G 0 /G 1 peak, debris factor and nuclei yield factor. Isolated nuclei were studied using fluorescence microscopy and bio-scanning electron microscopy to analyse stain-nuclei interaction and nuclei topology, respectively. Genome contents of 21 species belonging to these six genera were determined using MB01. Flow cytometric parameters showed significant differences among the analysed buffers. MB01 exhibited the best combination of analysed parameters; photomicrographs obtained from fluorescence and electron microscopy supported the superiority of MB01 buffer over other buffers. Among the 21 species studied, nuclear DNA contents of 14 species are reported for the first time. Results of the present study substantiate the enhanced efficacy of MB01, compared to other buffers tested, in the generation of acceptable cytograms from all species of Zingiberaceae studied. Our study facilitates new ways of sample preparation for further flow cytometric analysis of genome size of other members belonging to this highly complex polyploid family

  14. Standardizing flow cytometric assays in long-term population-based studies

    NASA Astrophysics Data System (ADS)

    Melzer, Susanne; Bocsi, Jozsef; Tárnok, Attila

    2015-03-01

    Quantification of leukocyte subpopulations and characterization of antigen-expression pattern on the cellular surface can play an important role in diagnostics. The state of cellular immunology on the single-cell level was analyzed by polychromatic flow cytometry in a recent comparative study within the average Leipzig population (LIFE - Leipzig Research Centre for Civilization Diseases). Data of 1699 subjects were recorded over a long-time period of three years (in a total of 1126 days). To ensure compatibility of such huge data sets, quality-controls on many levels (stability of instrumentation, low intra-laboratory variance and reader independent data analysis) are essential. The LIFE study aims to analyze various cytometric pattern to reveal the relationship between the life-style, the environmental effects and the individual health. We therefore present here a multi-step quality control procedure for long-term comparative studies.

  15. Flow cytometric quantitation of phagocytosis in heparinized complete blood with latex particles and Candida albicans.

    PubMed

    Egido, J M; Viñuelas, J

    1997-01-01

    We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripheral blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1 micron diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripheral blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.

  16. Flow cytometric and morphological analyses of Pinus pinaster somatic embryogenesis.

    PubMed

    Marum, Liliana; Loureiro, João; Rodriguez, Eleazar; Santos, Conceição; Oliveira, M Margarida; Miguel, Célia

    2009-09-25

    An approach combining morphological profiling and flow cytometric analysis was used to assess genetic stability during the several steps of somatic embryogenesis in Pinus pinaster. Embryogenic cell lines of P. pinaster were established from immature zygotic embryos excised from seeds obtained from open-pollinated trees. During the maturation stage, phenotype of somatic embryos was characterized as being either normal or abnormal. Based upon the prevalent morphological traits, different types of abnormal embryos underwent further classification and quantification. Nuclear DNA content of maritime pine using the zygotic embryos was estimated to be 57.04 pg/2C, using propidium iodide flow cytometry. According to the same methodology, no significant differences (P< or =0.01) in DNA ploidy were detected among the most frequently observed abnormal phenotypes, embryogenic cell lines, zygotic and normal somatic embryos, and somatic embryogenesis-derived plantlets. Although the differences in DNA ploidy level do not exclude the occurrence of a low level of aneuploidy, the results obtained point to the absence of major changes in ploidy level during the somatic embryogenesis process of this economically important species. Therefore, our primary goal of true-to-typeness was assured at this level.

  17. A Flow Cytometric and Computational Approaches to Carbapenems Affinity to the Different Types of Carbapenemases

    PubMed Central

    Pina-Vaz, Cidália; Silva, Ana P.; Faria-Ramos, Isabel; Teixeira-Santos, Rita; Moura, Daniel; Vieira, Tatiana F.; Sousa, Sérgio F.; Costa-de-Oliveira, Sofia; Cantón, Rafael; Rodrigues, Acácio G.

    2016-01-01

    The synergy of carbapenem combinations regarding Enterobacteriaceae producing different types of carbapenemases was study through different approaches: flow cytometry and computational analysis. Ten well characterized Enterobacteriaceae (KPC, verona integron-encoded metallo-β-lactamases –VIM and OXA-48-like enzymes) were selected for the study. The cells were incubated with a combination of ertapenem with imipenem, meropenem, or doripenem and killing kinetic curves performed with and without reinforcements of the drugs. A cephalosporin was also used in combination with ertapenem. A flow cytometric assay with DiBAC4-(3), a membrane potential dye, was developed in order to evaluate the cellular lesion after 2 h incubation. A chemical computational study was performed to understand the affinity of the different drugs to the different types of enzymes. Flow cytometric analysis and time-kill assays showed a synergic effect against KPC and OXA-48 producing-bacteria with all combinations; only ertapenem with imipenem was synergic against VIM producing-bacteria. A bactericidal effect was observed in OXA-48-like enzymes. Ceftazidime plus ertapenem was synergic against ESBL-negative KPC producing-bacteria. Ertapenem had the highest affinity for those enzymes according to chemical computational study. The synergic effect between ertapenem and others carbapenems against different carbapenemase-producing bacteria, representing a therapeutic choice, was described for the first time. Easier and faster laboratorial methods for carbapenemase characterization are urgently needed. The design of an ertapenem derivative with similar affinity to carbapenemases but exhibiting more stable bonds was demonstrated as highly desirable. PMID:27555844

  18. Rapid Assessment of Genotoxicity by Flow Cytometric Detection of Cell Cycle Alterations.

    PubMed

    Bihari, Nevenka

    2017-01-01

    Flow cytometry is a convenient method for the determination of genotoxic effects of environmental pollution and can reveal genotoxic compounds in unknown environmental mixtures. It is especially suitable for the analyses of large numbers of samples during monitoring programs. The speed of detection is one of the advantages of this technique which permits the acquisition of 10 4 -10 5 cells per sample in 5 min. This method can rapidly detect cell cycle alterations resulting from DNA damage. The outcome of such an analysis is a diagram of DNA content across the cell cycle which indicates cell proliferation, G 2 arrests, G 1 delays, apoptosis, and ploidy.Here, we present the flow cytometric procedure for rapid assessment of genotoxicity via detection of cell cycle alterations. The described protocol simplifies the analysis of genotoxic effects in marine environments and is suitable for monitoring purposes. It uses marine mussel cells in the analysis and can be adapted to investigations on a broad range of marine invertebrates.

  19. Flow cytometric osmotic fragility test and eosin-5'-maleimide dye-binding tests are better than conventional osmotic fragility tests for the diagnosis of hereditary spherocytosis.

    PubMed

    Arora, R D; Dass, J; Maydeo, S; Arya, V; Radhakrishnan, N; Sachdeva, A; Kotwal, J; Bhargava, M

    2018-06-01

    Hereditary spherocytosis (HS) is the most common inherited hemolytic anemia with heterogeneous clinico-laboratory manifestations. We evaluated the flow-cytometric tests: eosin-5'-maleimide (EMA) and flow-cytometric osmotic fragility test (FOFT) and the conventional osmotic fragility tests (OFT) for the diagnosis of hereditary spherocytosis (HS). One hundred two suspected HS patients underwent EMA, FOFT, incubated OFT (IOFT), and room temperature OFT (RT-OFT). In addition, 10 cases of immune hemolytic anemia (IHA) were included, and performance of the above 4 tests was evaluated. For EMA and FOFT, 5 normal controls were assessed together with the patients and cutoffs were calculated using receiver-operator-characteristics curve (ROC) analysis. The best cutoff for %EMA decrease was 12.5%, and for FOFT, %residual red cells (%RRC) was 25.6%. The sensitivity and specificity of RT-OFT was 62.06% and 86.3%, respectively, while that of IOFT was 79.31% and 87.67%, respectively. Both flow cytometric tests performed better. Sensitivity and specificity of EMA was 86.2% and 93.9% respectively, and that of FOFT was 96.6% and 98.63%, respectively. The combination of the FOFT with IOFT or EMA dye-binding test yields a sensitivity of 100%, but with EMA, it had a higher specificity. Hb/MCHC was a predictor of the severity of the disease while %EMA decrease and %RRC did not correlate with severity of the disease. Flow-cytometric osmotic fragility test is the best possible single test followed by EMA for diagnosis of HS. A combination of FOFT and EMA can correctly diagnose 100% patients. These tests are likely to replace conventional OFTs in future. © 2018 John Wiley & Sons Ltd.

  20. A flow-cytometric gram-staining technique for milk-associated bacteria.

    PubMed

    Holm, Claus; Jespersen, Lene

    2003-05-01

    A Gram-staining technique combining staining with two fluorescent stains, Oregon Green-conjugated wheat germ agglutinin (WGA) and hexidium iodide (HI) followed by flow-cytometric detection is described. WGA stains gram-positive bacteria while HI binds to the DNA of all bacteria after permeabilization by EDTA and incubation at 50 degrees C for 15 min. For WGA to bind to gram-positive bacteria, a 3 M potassium chloride solution was found to give the highest fluorescence intensity. A total of 12 strains representing some of the predominant bacterial species in bulk tank milk and mixtures of these were stained and analyzed by flow cytometry. Overall, the staining method showed a clear differentiation between gram-positive and gram-negative bacterial populations. For stationary-stage cultures of seven gram-positive bacteria and five gram-negative bacteria, an average of 99% of the cells were correctly interpreted. The method was only slightly influenced by the growth phase of the bacteria or conditions such as freezing at -18 degrees C for 24 h. For any of these conditions, an average of at least 95% of the cells were correctly interpreted. When stationary-stage cultures were stored at 5 degrees C for 14 days, an average of 86% of the cells were correctly interpreted. The Gram-staining technique was applied to the flow cytometry analysis of bulk tank milk inoculated with Staphylococcus aureus and Escherichia coli. These results demonstrate that the technique is suitable for analyzing milk samples without precultivation.

  1. Flow cytometric analysis of lectin binding to in vitro-cultured Perkinsus marinus surface carbohydrates

    USGS Publications Warehouse

    Gauthier, J.D.; Jenkins, J.A.; La Peyre, Jerome F.

    2004-01-01

    Parasite surface glycoconjugates are frequently involved in cellular recognition and colonization of the host. This study reports on the identification of Perkinsus marinus surface carbohydrates by flow cytometric analyses of fluorescein isothiocyanate-conjugated lectin binding. Lectin-binding specificity was confirmed by sugar inhibition and Kolmogorov-Smirnov statistics. Clear, measurable fluorescence peaks were discriminated, and no parasite autofluorescence was observed. Parasites (GTLA-5 and Perkinsus-1 strains) harvested during log and stationary phases of growth in a protein-free medium reacted strongly with concanavalin A and wheat germ agglutinin, which bind to glucose-mannose and N-acetyl-D-glucosamine (GlcNAc) moieties, respectively. Both P. marinus strains bound with lower intensity to Maclura pomifera agglutinin, Bauhinia purpurea agglutinin, soybean agglutinin (N-acetyl-D-galactosamine-specific lectins), peanut agglutinin (PNA) (terminal galactose specific), and Griffonia simplicifolia II (GlcNAc specific). Only background fluorescence levels were detected with Ulex europaeus agglutinin I (L-fucose specific) and Limulus polyphemus agglutinin (sialic acid specific). The lectin-binding profiles were similar for the 2 strains except for a greater relative binding intensity of PNA for Perkinsus-1 and an overall greater lectin-binding capacity of Perkinsus-1 compared with GTLA-5. Growth stage comparisons revealed increased lectin-binding intensities during stationary phase compared with log phase of growth. This is the first report of the identification of surface glycoconjugates on a Perkinsus spp. by flow cytometry and the first to demonstrate that differential surface sugar expression is growth phase and strain dependent. ?? American Society of Parasitologists 2004.

  2. Wide-field imaging and flow cytometric analysis of cancer cells in blood by fluorescent nanodiamond labeling and time gating

    NASA Astrophysics Data System (ADS)

    Hui, Yuen Yung; Su, Long-Jyun; Chen, Oliver Yenjyh; Chen, Yit-Tsong; Liu, Tzu-Ming; Chang, Huan-Cheng

    2014-07-01

    Nanodiamonds containing high density ensembles of negatively charged nitrogen-vacancy (NV-) centers are promising fluorescent biomarkers due to their excellent photostability and biocompatibility. The NV- centers in the particles have a fluorescence lifetime of up to 20 ns, which distinctly differs from those (<10 ns) of cell and tissue autofluorescence, making it possible to achieve background-free detection in vivo by time gating. Here, we demonstrate the feasibility of using fluorescent nanodiamonds (FNDs) as optical labels for wide-field time-gated fluorescence imaging and flow cytometric analysis of cancer cells with a nanosecond intensified charge-coupled device (ICCD) as the detector. The combined technique has allowed us to acquire fluorescence images of FND-labeled HeLa cells in whole blood covered with a chicken breast of ~0.1-mm thickness at the single cell level, and to detect individual FND-labeled HeLa cells in blood flowing through a microfluidic device at a frame rate of 23 Hz, as well as to locate and trace FND-labeled lung cancer cells in the blood vessels of a mouse ear. It opens a new window for real-time imaging and tracking of transplanted cells (such as stem cells) in vivo.

  3. Flow cytometric method for measuring chromatin fragmentation in fixed sperm from yellow perch (Perca flavescens).

    PubMed

    Jenkins, J A; Draugelis-Dale, R O; Pinkney, A E; Iwanowicz, L R; Blazer, V S

    2015-03-15

    Declining harvests of yellow perch, Perca flavescens, in urbanized watersheds of Chesapeake Bay have prompted investigations of their reproductive fitness. The purpose of this study was to establish a flow cytometric technique for DNA analysis of fixed samples sent from the field to provide reliable gamete quality measurements. Similar to the sperm chromatin structure assay, measures were made on the susceptibility of nuclear DNA to acid-induced denaturation, but used fixed rather than live or thawed cells. Nuclei were best exposed to the acid treatment for 1 minute at 37 °C followed by the addition of cold (4 °C) propidium iodide staining solution before flow cytometry. The rationale for protocol development is presented graphically through cytograms. Field results collected in 2008 and 2009 revealed DNA fragmentation up to 14.5%. In 2008, DNA fragmentation from the more urbanized watersheds was significantly greater than from reference sites (P = 0.026) and in 2009, higher percentages of haploid testicular cells were noted from the less urbanized watersheds (P = 0.032) indicating better reproductive condition at sites with less urbanization. For both years, total and progressive live sperm motilities by computer-assisted sperm motion analysis ranged from 19.1% to 76.5%, being significantly higher at the less urbanized sites (P < 0.05). This flow cytometric method takes advantage of the propensity of fragmented DNA to be denatured under standard conditions, or 1 minute at 37 °C with 10% buffered formalin-fixed cells. The study of fixed sperm makes possible the restrospective investigation of germplasm fragmentation, spermatogenic ploidy patterns, and chromatin compaction levels from samples translocated over distance and time. The protocol provides an approach that can be modified for other species across taxa. Published by Elsevier Inc.

  4. Flow cytometric method for measuring chromatin fragmentation in fixed sperm from yellow perch (Perca flavescens)

    USGS Publications Warehouse

    Jenkins, Jill A.; Draugelis-Dale, Rassa O.; Pinkney, Alfred E.; Iwanowicz, Luke R.; Blazer, Vicki

    2015-01-01

    Declining harvests of yellow perch, Perca flavescens, in urbanized watersheds of Chesapeake Bay have prompted investigations of their reproductive fitness. The purpose of this study was to establish a flow cytometric technique for DNA analysis of fixed samples sent from the field to provide reliable gamete quality measurements. Similar to the sperm chromatin structure assay, measures were made on the susceptibility of nuclear DNA to acid-induced denaturation, but used fixed rather than live or thawed cells. Nuclei were best exposed to the acid treatment for 1 minute at 37 °C followed by the addition of cold (4 °C) propidium iodide staining solution before flow cytometry. The rationale for protocol development is presented graphically through cytograms. Field results collected in 2008 and 2009 revealed DNA fragmentation up to 14.5%. In 2008, DNA fragmentation from the more urbanized watersheds was significantly greater than from reference sites (P = 0.026) and in 2009, higher percentages of haploid testicular cells were noted from the less urbanized watersheds (P = 0.032) indicating better reproductive condition at sites with less urbanization. For both years, total and progressive live sperm motilities by computer-assisted sperm motion analysis ranged from 19.1% to 76.5%, being significantly higher at the less urbanized sites (P < 0.05). This flow cytometric method takes advantage of the propensity of fragmented DNA to be denatured under standard conditions, or 1 minute at 37 °C with 10% buffered formalin–fixed cells. The study of fixed sperm makes possible the restrospective investigation of germplasm fragmentation, spermatogenic ploidy patterns, and chromatin compaction levels from samples translocated over distance and time. The protocol provides an approach that can be modified for other species across taxa.

  5. A Flow-Cytometric Gram-Staining Technique for Milk-Associated Bacteria

    PubMed Central

    Holm, Claus; Jespersen, Lene

    2003-01-01

    A Gram-staining technique combining staining with two fluorescent stains, Oregon Green-conjugated wheat germ agglutinin (WGA) and hexidium iodide (HI) followed by flow-cytometric detection is described. WGA stains gram-positive bacteria while HI binds to the DNA of all bacteria after permeabilization by EDTA and incubation at 50°C for 15 min. For WGA to bind to gram-positive bacteria, a 3 M potassium chloride solution was found to give the highest fluorescence intensity. A total of 12 strains representing some of the predominant bacterial species in bulk tank milk and mixtures of these were stained and analyzed by flow cytometry. Overall, the staining method showed a clear differentiation between gram-positive and gram-negative bacterial populations. For stationary-stage cultures of seven gram-positive bacteria and five gram-negative bacteria, an average of 99% of the cells were correctly interpreted. The method was only slightly influenced by the growth phase of the bacteria or conditions such as freezing at −18°C for 24 h. For any of these conditions, an average of at least 95% of the cells were correctly interpreted. When stationary-stage cultures were stored at 5°C for 14 days, an average of 86% of the cells were correctly interpreted. The Gram-staining technique was applied to the flow cytometry analysis of bulk tank milk inoculated with Staphylococcus aureus and Escherichia coli. These results demonstrate that the technique is suitable for analyzing milk samples without precultivation. PMID:12732558

  6. Flow Cytometric Analysis of Presynaptic Nerve Terminals Isolated from Rats Subjected to Hypergravity

    NASA Astrophysics Data System (ADS)

    Borisova, Tatiana

    2008-06-01

    Flow cytometric studies revealed an insignificant decrease in cell size heterogeneity and cytoplasmic granularity of rat brain nerve terminals (synaptosomes) isolated from animals subjected to centrifuge-induced hypergravity as compared to control ones. The analysis of plasma membrane potential using the potentiometric optical dye rhodamine 6G showed a decrease in fluorescence intensity by 10 % at steady state level in hypergravity synaptosomes. To monitor synaptic vesicle acidification we used pH-sensitive fluorescent dye acridine orange and demonstrated a lower fluorescence intensity level at steady state (10%) after hypergravity as compared to controls. Thus, exposure to hypergravity resulted in depolarization of the synaptosomal plasma membrane and diminution in synaptic vesicle acidification that may be a cause leading to altered synaptic neurotransmission.

  7. A six-colour flow cytometric method for simultaneous detection of cell phenotype and apoptosis of circulating endothelial cells.

    PubMed

    Mariucci, S; Rovati, B; Chatzileontiadou, S; Bencardino, K; Manzoni, M; Delfanti, S; Danova, M

    2009-01-01

    Blood circulating endothelial cells (CECs), with their resting and activated subsets, (rCECs and aCECs) and circulating progenitors cells (CEPs) are two extremely rare cell populations that are important in tissue vascularization. Their number and function are modulated in diseases involving vascular injury, such as human tumours. Although a consensus on the phenotypic definition of endothelial cells, as well as on the optimal enumeration technique, is still lacking, the number of clinical studies based on assessment of these cells is rapidly expanding, as well as the analytical methods employed. The present study aimed to develop a rapid and sensitive flow cytometric method of quantifying and characterizing CECs (with both their subsets and the apoptotic fraction) and CEPs. We analysed peripheral blood samples from 21 subjects with a six-colour flow cytometric approach allowing detection of the cell phenotype of CECs and CEPs using a monoclonal antibodies panel and a dedicated gating strategy. Apoptotic CECs were detected with Annexin V and dead cells with 7-amino-actinomycin D staining. The described technique proved to be a new, reliable, tool increasing our knowledge of the biology of CECs and CEPs and can readily be applied in the study of many pathological conditions characterized by endothelial damage.

  8. Empirically Optimized Flow Cytometric Immunoassay Validates Ambient Analyte Theory

    PubMed Central

    Parpia, Zaheer A.; Kelso, David M.

    2010-01-01

    Ekins’ ambient analyte theory predicts, counter intuitively, that an immunoassay’s limit of detection can be improved by reducing the amount of capture antibody. In addition, it also anticipates that results should be insensitive to the volume of sample as well as the amount of capture antibody added. The objective of this study is to empirically validate all of the performance characteristics predicted by Ekins’ theory. Flow cytometric analysis was used to detect binding between a fluorescent ligand and capture microparticles since it can directly measure fractional occupancy, the primary response variable in ambient analyte theory. After experimentally determining ambient analyte conditions, comparisons were carried out between ambient and non-ambient assays in terms of their signal strengths, limits of detection, and their sensitivity to variations in reaction volume and number of particles. The critical number of binding sites required for an assay to be in the ambient analyte region was estimated to be 0.1VKd. As predicted, such assays exhibited superior signal/noise levels and limits of detection; and were not affected by variations in sample volume and number of binding sites. When the signal detected measures fractional occupancy, ambient analyte theory is an excellent guide to developing assays with superior performance characteristics. PMID:20152793

  9. RNA flow cytometric FISH for investigations into HIV immunology, vaccination and cure strategies.

    PubMed

    Baxter, Amy E; Niessl, Julia; Morou, Antigoni; Kaufmann, Daniel E

    2017-09-12

    Despite the tremendous success of anti-retroviral therapy (ART) no current treatment can eradicate latent HIV reservoirs from HIV-infected individuals or generate, effective HIV-specific immunity. Technological limitations have hampered the identification and characterization of both HIV-infected cells and HIV-specific responses in clinical samples directly ex vivo. RNA-flow cytometric fluorescence in situ hybridisation (RNA Flow-FISH) is a powerful technique, which enables detection of mRNAs in conjunction with proteins at a single-cell level. Here, we describe how we are using this technology to address some of the major questions remaining in the HIV field in the era of ART. We discuss how CD4 T cell responses to HIV antigens, both following vaccination and HIV infection, can be characterized by measurement of cytokine mRNAs. We describe how our development of a dual HIV mRNA/protein assay (HIV RNA/Gag assay) enables high sensitivity detection of very rare HIV-infected cells and aids investigations into the translation-competent latent reservoir in the context of HIV cure.

  10. Flow cytometric detection of human immunodeficiency virus type 1 proviral DNA by the polymerase chain reaction incorporating digoxigenin- or fluorescein-labeled dUTP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Gang; Olson, J.C.; Pu, R.

    1995-10-01

    Serological assays are routinely used in the laboratory diagnosis of human immunodeficiency virus type-1 (HrV-1) infection, but the polymerase chain reaction (PCR) is ultimately the most sensitive and direct method for establishing definitive diagnosis. As an alternative to the conventional radioactive PCR procedure we have developed and evaluated a pair of rapid nonradioisotopic flow cytometric detection methods. Using heminested PCR we directly incorporated fluorescein-12-dUTP (fluo-dUTP) or digoxigenin-11-dUTP (dig-dUTP) into the PCR-amplicons. The labeled amplicons were hybridized with biotinylated antisense and sense probes, followed by capture of the hybrid DNA using streptavidin-coated beads which were finally analyzed in a flow cytometermore » by (1) direct detection of the fluorescence intensity of the amplicons incorporating fluo-dUTP and (2) immunodetection of the amplicons incorporating dig-dUTP by anti-digoxigenin IgG labeled with fluorescein isothiocyanate (FITC). Although both assays were functionally comparable with radiolabeled probe in reliably detecting as low as five copies of HIV-1 proviral DNA sequences, the immunodetection of dig-dUTP consistently yielded higher mean channel fluorescence and gave a stable signal over an extended period of 12-14 weeks. In testing a panel of 20 pedigreed PBMC specimens from blood donors with or without HIV-1 infection, the results of both flow cytometric assays were identical with those of the conventional radioactive procedure. Therefore, we conclude that the dig-dUTP incorporation in amplicons, hybridization with a pair of sense-antisense biotinylated probes and immunodetection of hybrids by flow cytometric analyses is the nonisotopic method of choice for PCR-diagnosis of HIV-1 infection. 21 refs., 2 figs., 4 tabs.« less

  11. Flow cytometric analysis of crayfish haemocytes activated by lipopolysaccharides

    USGS Publications Warehouse

    Cardenas, W.; Dankert, J.R.; Jenkins, J.A.

    2004-01-01

    Lipopolysaccharides (LPS) from Gram-negative bacteria are strong stimulators of white river crayfish, Procambarus zonangulus, haemocytes in vitro. Following haemocyte treatment with LPS and with LPS from rough mutant R5 (LPS Rc) from Salmonella minnesota, flow cytometric analysis revealed a conspicuous and reproducible decrease in cell size as compared to control haemocytes. These LPS molecules also caused a reduction in haemocyte viability as assessed by flow cytometry with the fluorescent dyes calcein-AM and ethidium homodimer. The onset of cell size reduction was gradual and occurred prior to cell death. Haemocytes treated with LPS from S. minnesota without the Lipid A moiety (detoxified LPS) decreased in size without a reduction of viability. The action of LPS on crayfish haemocytes appeared to be related to the activation of the prophenoloxidase system because phenoloxidase (PO)-specific activity in the supernatants from control and detoxified LPS-treated cells was significantly lower than that from LPS and LPS-Rc treated cells (P < 0.05). Furthermore, addition of trypsin inhibitor to the LPS treatments caused noticeable delays in cell size and viability changes. These patterns of cellular activation by LPS formulations indicated that crayfish haemocytes react differently to the polysaccharide and lipid A moieties of LPS, where lipid A is cytotoxic and the polysaccharide portion is stimulatory. These effects concur with the general pattern of mammalian cell activation by LPS, thereby indicting commone innate immune recognition mechanisms to bacterial antigens between cells from mammals and invertebrates. These definitive molecular approaches used to verify and identify mechanisms of invertbrate haemocyte responses to LPS could be applied with other glycoconjugates, soluble mediators, or xenobiotic compounds.

  12. Flow cytometric characterization of freshwater crayfish hemocytes for the examination of physiological status in wild and captive animals.

    PubMed

    Taylor, Sean; Landman, Michael J; Ling, Nicholas

    2009-09-01

    Enumeration of invertebrate hemocytes is a potentially powerful tool for the determination of physiological effects of extrinsic stressors, such as hypoxia, disease, and toxicant exposure. A detailed flow cytometric method of broad application was developed for the objective characterization and enumeration of the hemocytes of New Zealand freshwater crayfish Paranephrops planifrons for the purpose of physiological health assessment. Hemocyte populations were isolated by flow cytometric sorting based on differential light scatter properties followed by morphological characterization via light microscopy and software image analysis. Cells were identified as hyaline, semigranular, and granular hemocytes based on established invertebrate hemocyte classification. A characteristic decrease in nuclear size, an increase in granularity between the hyaline and granular cells, and the eccentric location of nuclei in granular cells were also observed. The granulocyte subpopulations were observed to possess varying degrees of granularity. The developed methodology was used to perform total and differential hemocyte counts from three lake populations and between wild and captive crayfish specimens. Differences in total and differential hemocyte counts were not observed among the wild populations. However, specimens held in captivity for 14 d exhibited a significant 63% reduction in total hemocyte count, whereas the relative hemocyte proportions remained the same. These results demonstrate the utility of this method for the investigation of subacute stressor effects in selected decapod crustaceans.

  13. Automated analysis of flow cytometric data for measuring neutrophil CD64 expression using a multi-instrument compatible probability state model.

    PubMed

    Wong, Linda; Hill, Beth L; Hunsberger, Benjamin C; Bagwell, C Bruce; Curtis, Adam D; Davis, Bruce H

    2015-01-01

    Leuko64™ (Trillium Diagnostics) is a flow cytometric assay that measures neutrophil CD64 expression and serves as an in vitro indicator of infection/sepsis or the presence of a systemic acute inflammatory response. Leuko64 assay currently utilizes QuantiCALC, a semiautomated software that employs cluster algorithms to define cell populations. The software reduces subjective gating decisions, resulting in interanalyst variability of <5%. We evaluated a completely automated approach to measuring neutrophil CD64 expression using GemStone™ (Verity Software House) and probability state modeling (PSM). Four hundred and fifty-seven human blood samples were processed using the Leuko64 assay. Samples were analyzed on four different flow cytometer models: BD FACSCanto II, BD FACScan, BC Gallios/Navios, and BC FC500. A probability state model was designed to identify calibration beads and three leukocyte subpopulations based on differences in intensity levels of several parameters. PSM automatically calculates CD64 index values for each cell population using equations programmed into the model. GemStone software uses PSM that requires no operator intervention, thus totally automating data analysis and internal quality control flagging. Expert analysis with the predicate method (QuantiCALC) was performed. Interanalyst precision was evaluated for both methods of data analysis. PSM with GemStone correlates well with the expert manual analysis, r(2) = 0.99675 for the neutrophil CD64 index values with no intermethod bias detected. The average interanalyst imprecision for the QuantiCALC method was 1.06% (range 0.00-7.94%), which was reduced to 0.00% with the GemStone PSM. The operator-to-operator agreement in GemStone was a perfect correlation, r(2) = 1.000. Automated quantification of CD64 index values produced results that strongly correlate with expert analysis using a standard gate-based data analysis method. PSM successfully evaluated flow cytometric data generated

  14. A cluster analysis method for identification of subpopulations of cells in flow cytometric list-mode arrays

    NASA Technical Reports Server (NTRS)

    Li, Z. K.

    1985-01-01

    A specialized program was developed for flow cytometric list-mode data using an heirarchical tree method for identifying and enumerating individual subpopulations, the method of principal components for a two-dimensional display of 6-parameter data array, and a standard sorting algorithm for characterizing subpopulations. The program was tested against a published data set subjected to cluster analysis and experimental data sets from controlled flow cytometry experiments using a Coulter Electronics EPICS V Cell Sorter. A version of the program in compiled BASIC is usable on a 16-bit microcomputer with the MS-DOS operating system. It is specialized for 6 parameters and up to 20,000 cells. Its two-dimensional display of Euclidean distances reveals clusters clearly, as does its 1-dimensional display. The identified subpopulations can, in suitable experiments, be related to functional subpopulations of cells.

  15. Flow cytometric evaluation of physico-chemical impact on Gram-positive and Gram-negative bacteria

    PubMed Central

    Fröhling, Antje; Schlüter, Oliver

    2015-01-01

    Since heat sensitivity of fruits and vegetables limits the application of thermal inactivation processes, new emerging inactivation technologies have to be established to fulfill the requirements of food safety without affecting the produce quality. The efficiency of inactivation treatments has to be ensured and monitored. Monitoring of inactivation effects is commonly performed using traditional cultivation methods which have the disadvantage of the time span needed to obtain results. The aim of this study was to compare the inactivation effects of peracetic acid (PAA), ozonated water (O3), and cold atmospheric pressure plasma (CAPP) on Gram-positive and Gram-negative bacteria using flow cytometric methods. E. coli cells were completely depolarized after treatment (15 s) with 0.25% PAA at 10°C, and after treatment (10 s) with 3.8 mg l−1 O3 at 12°C. The membrane potential of CAPP treated cells remained almost constant at an operating power of 20 W over a time period of 3 min, and subsequently decreased within 30 s of further treatment. Complete membrane permeabilization was observed after 10 s O3 treatment, but treatment with PAA and CAPP did not completely permeabilize the cells within 2 and 4 min, respectively. Similar results were obtained for esterase activity. O3 inactivates cellular esterase but esterase activity was detected after 4 min CAPP treatment and 2 min PAA treatment. L. innocua cells and P. carotovorum cells were also permeabilized instantaneously by O3 treatment at concentrations of 3.8 ± 1 mg l−1. However, higher membrane permeabilization of L. innocua and P. carotovorum than of E. coli was observed at CAPP treatment of 20 W. The degree of bacterial damage due to the inactivation processes is highly dependent on treatment parameters as well as on treated bacteria. Important information regarding the inactivation mechanisms can be obtained by flow cytometric measurements and this enables the definition of critical process parameters. PMID

  16. Practical selection methods for rat and mouse round spermatids without DNA staining by flow cytometric cell sorting.

    PubMed

    Hayama, Tomonari; Yamaguchi, Tomoyuki; Kato-Itoh, Megumi; Ishii, Yumiko; Mizuno, Naoaki; Umino, Ayumi; Sato, Hideyuki; Sanbo, Makoto; Hamanaka, Sanae; Masaki, Hideki; Hirabayashi, Masumi; Nakauchi, Hiromitsu

    2016-06-01

    Round spermatid injection (ROSI) into unfertilized oocytes enables a male with a severe spermatogenesis disorder to have children. One limitation of the application of this technique in the clinic is the identification and isolation of round spermatids from testis tissue. Here we developed an efficient and simple method to isolate rodent haploid round spermatids using flow cytometric cell sorting, based on DNA content (stained with Hoechst 33342 or Dye Cycle Violet) or by cell diameter and granularity (forward and side scatter). ROSI was performed with round spermatids selected by flow cytometry, and we obtained healthy offspring from unstained cells. This non-invasive method could therefore be an effective option for breeding domestic animals and human male infertility treatment. Mol. Reprod. Dev. 83: 488-496, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Transient myeloproliferative disease of the newborn: case report with placental, cytogenetic, and flow cytometric findings.

    PubMed

    de Tar, M W; Dittman, W; Gilbert, J

    2000-03-01

    Transient myeloproliferative disease (TMD) of the newborn is a rare hematologic abnormality associated with trisomy 21. It is frequently difficult to distinguish the disorder from true congenital leukemia (TCL). Unlike leukemia, which has a clinically aggressive course, TMD generally resolves within weeks to months. We present a case of TMD of the newborn diagnosed on the basis of peripheral blood studies and describe the pertinent pathological findings within the placenta. Flow cytometric analysis of the blasts in the peripheral blood showed phenotypic heterogeneity with features consistent with megakaryocytic differentiation. Cytogenetic studies showed trisomy 21 within the blastic cells. The placenta showed villous dysmaturity with associated chorangiosis and prominent intravascular aggregates of primitive-appearing cells with focal, early vascular wall invasion. The neonate recovered fully and shows no evidence of disease at 2 years of age.

  18. Integrating molecular diagnostic and flow cytometric reporting for improved longitudinal monitoring of HIV patients.

    PubMed Central

    Asare, A. L.; Huda, H.; Klimczak, J. C.; Caldwell, C. W.

    1998-01-01

    Studies have shown that monitoring HIV-infected patients undergoing antiretroviral therapy is best represented by combined measurement of plasma HIV-1 RNA and CD4+ T-lymphocytes [1]. This pilot study at the University of Missouri-Columbia integrates molecular diagnostic and flow cytometric data reporting to provide current and historical HIV-1 RNA levels and CD4+ T-cell counts. The development of a single database for storage and retrieval of these values facilitates composite report generation that includes longitudinal HIV-1 RNA levels and CD4+ T-cell counts for all patients. Results are displayed in tables and plotted graphically within a web browser. This method of data presentation converts individual data points to more useful medical information and could provide clinicians with decision support for improved monitoring of HIV patients undergoing antiretroviral therapy. Images Figure 2 Figure 3 Figure 4 PMID:9929359

  19. Flow cytometric detection of endothelial microparticles (EMP): effects of centrifugation and storage alter with the phenotype studied.

    PubMed

    van Ierssel, Sabrina H; Van Craenenbroeck, Emeline M; Conraads, Viviane M; Van Tendeloo, Viggo F; Vrints, Christiaan J; Jorens, Philippe G; Hoymans, Vicky Y

    2010-04-01

    Endothelial microparticles (EMP) are released into the circulation in case of endothelial disturbance, and are therefore increasingly investigated as a biomarker reflecting disease activity. Numerous pre-analytic methods have been proposed for their flow cytometric enumeration, but standardization is still lacking. In this study we evaluated the influence of centrifugation and storage conditions on EMP quantification. Platelet-poor plasma (PPP) from 10 healthy volunteers was prepared by centrifugation at 1,550 g for 20 minutes twice. A first aliquot of PPP was analyzed immediately, a second after storage at 4 degrees C for 7 hours. A third and fourth aliquot were snap-frozen and stored at -80 degrees C for 7 and 28 days. A final aliquot was further centrifuged at 10,000g for 10 minutes and analyzed immediately. EMP were defined as CD31+CD42b-, CD62E+, CD144+ or CD144+CD105+ particles, smaller than 1.0 microm. High speed centrifugation led to a significant loss of CD31+CD42b- EMP (p=0.004). A good correlation between PPP and high speed centrifuged PPP was only found for CD144+ EMP (Kendall tau b=0.611, p=0.025). Storage at 4 degrees C did not affect EMP quantification. However, freezing at -80 degrees C increased CD31+CD42b- and CD62E+ EMP counts, and lowered CD144+ EMP (p<0.05). Nevertheless, the agreement among the different storage conditions was relatively good (Kendall coefficient of concordance >0.487; p<0.05). The flow cytometric detection of EMP varies with the centrifugation protocol and the storage method used, and these changes also depend on the phenotype studied. The results of this study caution against comparing study results gathered with different EMP laboratory protocols. (c) 2010 Elsevier Ltd. All rights reserved.

  20. Is flow cytometric evaluation of DNA degradation a reliable method to investigate the early postmortem period?

    PubMed

    Di Nunno, N R; Costantinides, F; Bernasconi, P; Bottin, C; Melato, M

    1998-03-01

    The time of death can be established by determining the length of the postmortem interval. Many methods have been proposed to achieve this goal. Flow cytometric evaluation of DNA degradation seems to be reliable for the first 72 hours after death. Our study evaluated the correspondence of the corruption process between in vitro and corpse tissues. We chose spleen tissue to perform our investigation because it is rich in nucleated cells. Results showed a precise correspondence between the two kinds of samples in the time period between 24 and 36 hours. The period from 36 to 72 hours is characterized by a much looser correspondence than that found in the first period. After the first 72 hours, DNA denaturation is massive and does not allow useful cytofluorimetric readings. The spleen does not seem to be the most suitable organ for this type of investigation because it tends to colliquate very rapidly. We therefore are evaluating other organs to identify a more suitable tissue source for the investigation of longer postmortem period using flow cytometry.

  1. Use of LysoTracker dyes: a flow cytometric study of autophagy.

    PubMed

    Chikte, Shaheen; Panchal, Neelam; Warnes, Gary

    2014-02-01

    The flow cytometric use of LysoTracker dyes was employed to investigate the autophagic process and to compare this with the upregulation of autophagy marker, the microtubule-associated protein LC3B. Although the mechanism of action of LysoTracker dyes is not fully understood, they have been used in microscopy to image acidic spherical organelles, and their use in flow cytometry has not been thoroughly investigated in the study of autophagy. This investigation uses numerous autophagy-inducing agents including chloroquine (CQ), rapamycin, low serum (<1%) RPMI, and nutrient starvation to induce autophagy in Jurkat T-cell leukemia and K562 erythromyeloid cell lines. LC3B showed an increase with CQ treatment although this was different to LysoTracker signals in terms of dose and time. Rapamycin, low serum (<1%) RPMI, and nutrient starvation induction of autophagy also induced an increase in LysoTracker and LC3B signals. CQ also induced apoptosis in cell lines, which was blocked by pan-caspase inhibitor z-VAD resulting in a reduction in cells undergoing apoptosis and a subsequent upregulation of autophagic markers LC3B and lysosomal dye signals. Given that LC3B and LysoTracker are measuring different biological events in the autophagic process, they surprisingly both upregulated during autophagic process. This study, however, shows that although LysoTracker dyes do not specifically label lysosomes or autophagosomes within the cell, they allow the simultaneous measurement of an autophagy-related process and other live-cell functions, which are not possible with the standard LC3B antibody-labeling technique. This method has the advantage of other live-cell LCB-GFP-tagged experiments in that be used to analyze patient cells as well as easier to use and significantly less costly. Copyright © 2013 International Society for Advancement of Cytometry.

  2. The G6PD flow-cytometric assay is a reliable tool for diagnosis of G6PD deficiency in women and anaemic subjects.

    PubMed

    Bancone, Germana; Kalnoky, Michael; Chu, Cindy S; Chowwiwat, Nongnud; Kahn, Maria; Malleret, Benoit; Wilaisrisak, Pornpimon; Rénia, Laurent; Domingo, Gonzalo J; Nosten, Francois

    2017-08-29

    Glucose-6-phosphate dehydrogenase (G6PD) activity is essential for redox equilibrium of red blood cells (RBCs) and, when compromised, the RBCs are more susceptible to haemolysis. 8-aminoquinolines (primaquine and tafenoquine) are used for the radical curative treatment of Plasmodium vivax malaria and can cause haemolysis in G6PD deficient subjects. Haemolytic risk is dependent on treatment dose and patient G6PD status but ultimately it correlates with the number of G6PD deficient RBCs. The G6PD spectrophotometric assay reliably identifies deficient subjects but is less reliable in heterozygous females, especially when other blood conditions are present. In this work we analysed samples with a range of G6PD phenotypes and haematologic conditions from 243 healthy volunteers of Asian or African-American heritage using both the spectrophotomeric assay and the G6PD flow-cytometric assay. Overall 18.5% of subjects (29.3% of Asian females) presented with anaemia, associated with decreased RBCs volume (MCV) and reticulocytosis; the flow-cytometric assay showed good correlation with the spectrophotometric assay (Pearson's r 0.918-0.957) and was less influenced by haemoglobin concentration, number of RBCs and number of reticulocytes. This resulted in more precise quantification of the number of G6PD deficient RBCs and presumably higher predictive power of drug induced haemolytic risk.

  3. Flow cytometry of duodenal intraepithelial lymphocytes improves diagnosis of celiac disease in difficult cases

    PubMed Central

    Morgado, José Mario T; Ruiz-Martín, Juan; Guardiola, Antonio; Lopes-Nogueras, Miriam; García-Vela, Almudena; Martín-Sacristán, Beatriz; Sánchez-Muñoz, Laura

    2016-01-01

    Background Diagnosis of celiac disease is difficult when the combined results of serology and histology are inconclusive. Studies using flow cytometry of intraepithelial lymphocytes (IELs) have found that celiac patients have increased numbers of γδ IELs, along with a decrease in CD3-CD103 + IELs. Objective The objective of this article is to assess the role of flow cytometric analysis of IELs in the diagnosis of celiac disease in difficult cases. Methods A total of 312 patients with suspicion of celiac disease were included in the study. Duodenal biopsy samples were used for histological assessment and for flow cytometric analysis of IELs. Results In 46 out of 312 cases (14.7%) the combination of serology and histology did not allow the confirmation or exclusion of celiac disease. HLA typing had been performed in 42 of these difficult cases. Taking into account HLA typing and the response to a gluten-free diet, celiac disease was excluded in 30 of these cases and confirmed in the remaining 12. Flow cytometric analysis of IELs allowed a correct diagnosis in 39 out of 42 difficult cases (92.8%) and had a sensitivity of 91.7% (95% CI: 61.5% to 99.8%) and a specificity of 93.3% (95% CI: 77.9% to 99.2%) for the diagnosis of celiac disease in this setting. Conclusion Flow cytometric analysis of IELs is useful for the diagnosis of celiac disease in difficult cases. PMID:29026596

  4. Method for flow cytometric monitoring of Renibacterium salmoninarum inactivation

    USGS Publications Warehouse

    Pascho, R.J.; Ongerth, J.E.

    2000-01-01

    The slow growth of Renibacterium salmoninarum limits the usefulness of culture as a research tool. Development of a 2-color flow cytometric assay to quantify the proportions of live and dead R. salmoninarum in a test population is described. Bacteria were simultaneously stained with fluorescein isothiocyanate-conjugated immunoglobulin and exposed to the exclusion dye propidium iodide. Propidium iodide red fluorescence profiles of control groups of untreated and killed R. salmoninarum were compared with those for bacteria exposed to chlorine. Bacterial inactivation was based on mean red fluorescence intensity, and analyzed by high-red fluorescence intensity (HRFI) and curve subtraction (CS) analyses. When the concentration of R. salmoninarum was 8.65 x 106 bacteria ml-1 and the bacteria exposed to chlorine at 1 mg l-1 for periods from 1 to 20 min (high-Rs assessment), the mean red fluorescence intensity of the profile for each chlorine-exposure group was higher than that for the untreated control (p < 0.0001). When the concentration of R. salmoninarum was reduced to 1.76 x 106 bacteria ml-1 and exposed to 0.8 mg l-1 free chlorine level for periods from 20 s to 5 min (reduced-Rs assessment), the mean red fluorescence intensities of the exposure groups were higher than that for the untreated control only when the R. salmoninarum was exposed to chlorine for at least 1 min (p ??? 0.01). On the basis of red fluorescence intensity, the proportion of dead cells generally increased with the duration of chlorine exposure. Whereas the rates of inactivation derived from the HRFI and CS analyses did not correlate with the duration of exposure in the high-Rs assessment (r2 ??? 0.27), there was a correlation between these estimates and the duration of exposure in the reduced-Rs assessment (r2 ??? 0.92). Because of the rapid loss of culturable R. salmoninarum in both assessments following chlorine exposure, neither the duration of exposure nor the inactivation estimates correlated

  5. Determination of chitin content in fungal cell wall: an alternative flow cytometric method.

    PubMed

    Costa-de-Oliveira, Sofia; Silva, Ana P; Miranda, Isabel M; Salvador, Alexandre; Azevedo, Maria M; Munro, Carol A; Rodrigues, Acácio G; Pina-Vaz, Cidália

    2013-03-01

    The conventional methods used to evaluate chitin content in fungi, such as biochemical assessment of glucosamine release after acid hydrolysis or epifluorescence microscopy, are low throughput, laborious, time-consuming, and cannot evaluate a large number of cells. We developed a flow cytometric assay, efficient, and fast, based on Calcofluor White staining to measure chitin content in yeast cells. A staining index was defined, its value was directly related to chitin amount and taking into consideration the different levels of autofluorecence. Twenty-two Candida spp. and four Cryptococcus neoformans clinical isolates with distinct susceptibility profiles to caspofungin were evaluated. Candida albicans clinical isolate SC5314, and isogenic strains with deletions in chitin synthase 3 (chs3Δ/chs3Δ) and genes encoding predicted GlycosylPhosphatidylInositol (GPI)-anchored proteins (pga31Δ/Δ and pga62Δ/Δ), were used as controls. As expected, the wild-type strain displayed a significant higher chitin content (P < 0.001) than chs3Δ/chs3Δ and pga31Δ/Δ especially in the presence of caspofungin. Ca. parapsilosis, Ca. tropicalis, and Ca. albicans showed higher cell wall chitin content. Although no relationship between chitin content and antifungal drug susceptibility phenotype was found, an association was established between the paradoxical growth effect in the presence of high caspofungin concentrations and the chitin content. This novel flow cytometry protocol revealed to be a simple and reliable assay to estimate cell wall chitin content of fungi. Copyright © 2013 International Society for Advancement of Cytometry.

  6. A novel tool for high-throughput screening of granulocyte-specific antibodies using the automated flow cytometric granulocyte immunofluorescence test (Flow-GIFT).

    PubMed

    Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald

    2011-02-03

    Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.

  7. Expanding the potential of standard flow cytometry by extracting fluorescence lifetimes from cytometric pulse shifts

    PubMed Central

    Cao, Ruofan; Naivar, Mark A; Wilder, Mark; Houston, Jessica P

    2014-01-01

    Fluorescence lifetime measurements provide information about the fluorescence relaxation, or intensity decay, of organic fluorophores, fluorescent proteins, and other inorganic molecules that fluoresce. The fluorescence lifetime is emerging in flow cytometry and is helpful in a variety of multiparametric, single cell measurements because it is not impacted by nonlinearity that can occur with fluorescence intensity measurements. Yet time-resolved cytometry systems rely on major hardware modifications making the methodology difficult to reproduce. The motivation of this work is, by taking advantage of the dynamic nature of flow cytometry sample detection and applying digital signal processing methods, to measure fluorescence lifetimes using an unmodified flow cytometer. We collect a new lifetime-dependent parameter, referred to herein as the fluorescence-pulse-delay (FPD), and prove it is a valid representation of the average fluorescence lifetime. To verify we generated cytometric pulses in simulation, with light emitting diode (LED) pulsation, and with true fluorescence measurements of cells and microspheres. Each pulse is digitized and used in algorithms to extract an average fluorescence lifetime inherent in the signal. A range of fluorescence lifetimes is measurable with this approach including standard organic fluorophore lifetimes (∼1 to 22 ns) as well as small, simulated shifts (0.1 ns) under standard conditions (reported herein). This contribution demonstrates how digital data acquisition and signal processing can reveal time-dependent information foreshadowing the exploitation of full waveform analysis for quantification of similar photo-physical events within single cells. © 2014 The Authors. Published by Wiley Periodicals, Inc. PMID:25274073

  8. Fine-needle aspiration cytology of malignant hemangiopericytomas with ultrastructural and flow cytometric analyses.

    PubMed

    Geisinger, K R; Silverman, J F; Cappellari, J O; Dabbs, D J

    1990-07-01

    A hemangiopericytoma (HPC) is an uncommon soft-tissue neoplasm that may arise in many body sites. The cytologic features of fine-needle aspirates (FNAs) of HPCs have only rarely been described in the literature. We examined FNAs of malignant HPCs from the head and neck region (three) and the retroperitoneum (one) in four adults (aged 38 to 83 years). All four FNAs yielded cellular specimens that consisted of uninuclear tumor cells with high nuclear-cytoplasmic ratios. The cytomorphological spectrum included nuclei that were oval to elongate and had very finely granular, evenly distributed chromatin with one or two small but distinct nucleoli. Hemangiopericytomas yield aspirates that may be considered malignant and may suggest sarcoma. Histologically, all four neoplasms manifested high mitotic activity. The ultrastructural features of all four tumors were supportive of the diagnosis of HPC. Although a specific primary diagnosis of HPC on FNA of a soft-tissue mass is unlikely, cytologic analysis may allow diagnosis of recurrent or metastatic HPC. We were able to perform flow cytometric determinations of tumor DNA content on three of the resected neoplasms. In two, an aneuploid pattern was found, including the neoplasm with the most marked pleomorphism in the FNA. The third was diploid.

  9. Flow cytometric method for scoring rat liver micronuclei with simultaneous assessments of hepatocyte proliferation.

    PubMed

    Avlasevich, Svetlana L; Khanal, Sumee; Singh, Priyanka; Torous, Dorothea K; Bemis, Jeffrey C; Dertinger, Stephen D

    2018-04-01

    The current report describes a newly devised method for automatically scoring the incidence of rat hepatocyte micronuclei (MNHEP) via flow cytometry, with concurrent assessments of hepatocyte proliferation-frequency of Ki-67-positive nuclei, and the proportion of polyploid nuclei. Proof-of-concept data are provided from experiments performed with 6-week old male Crl:CD(SD) rats exposed to diethylnitrosamine (DEN) or quinoline (QUIN) for 3 or 14 consecutive days. Non-perfused liver tissue was collected 4 days after cessation of treatment in the case of 3-day studies, or 1 day after last administration in the case of 14-day studies for processing and flow cytometric analysis. In addition to livers, blood samples were collected one day after final treatment for micronucleated reticulocyte (MN-RET) measurements. Dose-dependent increases in MNHEP, Ki-67-positive nuclei, and polyploidy were observed in 3- and 14-day DEN studies. Both treatment schedules resulted in elevated %MNHEP for QUIN-exposed rats, and while cell proliferation effects were subtle, appreciable increases to normalized liver weights were observed. Whereas DEN caused markedly higher %MNHEP when exposure was extended to two weeks, QUIN-induced MNHEP were slightly increased with protracted dosing. Parallel microscopy-based MNHEP frequencies were highly correlated with flow cytometry-based measurements (four study/aggregate R 2  = 0.80). No increases in MN-RET were seen in any of the four studies. Collectively, these results suggest liver micronuclei are amenable to an automated scoring technique that provides objective analyses and higher information content relative to conventional microscopy. Additional work is needed to expand the number and types of chemicals tested, identify the most advantageous treatment schedules, and test the transferability of the method. Environ. Mol. Mutagen. 59:176-187, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  10. The extended leukocyte differential count using the Cytodiff flow cytometric system reveals that higher CD16+ cytotoxic NK+T lymphocyte levels predict superior survival outcomes in patients with metastatic carcinoma.

    PubMed

    Park, Borae G; Park, Chan-Jeoung; Yoon, Chan-Hee; Jang, Seongsoo; Chi, Hyun-Sook; Ryu, Min-Hee; Kim, Sang-We

    2013-05-01

    The recently developed Cytodiff flow cytometric system (Beckman Coulter, Miami, FL) enables leukocyte analysis using a single immunophenotyping panel tube composed of six markers and five colors and that can detect 16 leukocyte subpopulations. We performed a preliminary investigation of whether changes in any of 16 leukocyte differentials were associated with survival and treatment outcomes in patients with metastatic carcinoma or not. We measured 16 leukocyte differential counts using the Cytodiff flow cytometric system in peripheral blood samples from 40 patients with metastatic malignancy (27 stomach cancer and 13 lung cancer) before chemotherapy and at 15 day intervals after chemotherapy for 2 months. A higher percentage of CD16+ cytotoxic NK+T lymphocytes was found to be the only significant prognostic factor among by Cox regression analysis and a higher percentage of CD16+ cytotoxic NK+T lymphocytes (>5.0%) showed significantly longer survival outcomes by Kaplan-Meier analysis (P = 0.003). The Cytodiff system enables 16 leukocyte subpopulations in a one tube assay and also can operate with only small amounts of sample, although it cannot differentiate NK cells from T lymphocytes. Hence, the monitoring of all leukocyte subpopulations using Cytodiff flow cytometry may be a helpful prognostic tool for patients with metastatic carcinoma. Copyright © 2012 International Clinical Cytometry Society.

  11. Flow cytometric analysis of cell-surface and intracellular antigens in leukemia diagnosis.

    PubMed

    Knapp, W; Strobl, H; Majdic, O

    1994-12-15

    New technology allows highly sensitive flow cytometric detection and quantitative analysis of intracellular antigens in normal and malignant hemopoietic cells. With this technology, the earliest stages of myeloid and lymphoid differentiation can easily and reliably be identified using antibodies directed against (pro-)myeloperoxidase/MPO, CD22 and CD3 antigens, respectively. Particularly for the analysis of undifferentiated acute myeloblastic leukemia (AML) cells, the immunological demonstration of intracellular MPO or its enzymatically inactive proforms is highly relevant, since other myeloid marker molecules such as CD33, CD13, or CDw65 are either not restricted to the granulomonocytic lineage or appear later in differentiation. By combining MPO staining with staining for lactoferrin (LF), undifferentiated cells can be distinguished from the granulomonocytic maturation compartment in bone marrow, since LF is selectively expressed from the myelocyte stage of differentiation onward. The list of informative intracellular antigens to be used in leukemia cell analysis will certainly expand in the near future. One candidate, intracellular CD68, has already been tested by us, and results are presented. Also dealt within this article are surface marker molecules not (as yet) widely used in leukemia cell analysis but with the potential to provide important additional information. Among them are the surface structures CD15, CD15s, CDw65, CD79a (MB-1), CD79b (B29), CD87 (uPA-R), and CD117 (c-kit).

  12. Flow Cytometric Detection of PrPSc in Neurons and Glial Cells from Prion-Infected Mouse Brains.

    PubMed

    Yamasaki, Takeshi; Suzuki, Akio; Hasebe, Rie; Horiuchi, Motohiro

    2018-01-01

    In prion diseases, an abnormal isoform of prion protein (PrP Sc ) accumulates in neurons, astrocytes, and microglia in the brains of animals affected by prions. Detailed analyses of PrP Sc -positive neurons and glial cells are required to clarify their pathophysiological roles in the disease. Here, we report a novel method for the detection of PrP Sc in neurons and glial cells from the brains of prion-infected mice by flow cytometry using PrP Sc -specific staining with monoclonal antibody (MAb) 132. The combination of PrP Sc staining and immunolabeling of neural cell markers clearly distinguished neurons, astrocytes, and microglia that were positive for PrP Sc from those that were PrP Sc negative. The flow cytometric analysis of PrP Sc revealed the appearance of PrP Sc -positive neurons, astrocytes, and microglia at 60 days after intracerebral prion inoculation, suggesting the presence of PrP Sc in the glial cells, as well as in neurons, from an early stage of infection. Moreover, the kinetic analysis of PrP Sc revealed a continuous increase in the proportion of PrP Sc -positive cells for all cell types with disease progression. Finally, we applied this method to isolate neurons, astrocytes, and microglia positive for PrP Sc from a prion-infected mouse brain by florescence-activated cell sorting. The method described here enables comprehensive analyses specific to PrP Sc -positive neurons, astrocytes, and microglia that will contribute to the understanding of the pathophysiological roles of neurons and glial cells in PrP Sc -associated pathogenesis. IMPORTANCE Although formation of PrP Sc in neurons is associated closely with neurodegeneration in prion diseases, the mechanism of neurodegeneration is not understood completely. On the other hand, recent studies proposed the important roles of glial cells in PrP Sc -associated pathogenesis, such as the intracerebral spread of PrP Sc and clearance of PrP Sc from the brain. Despite the great need for detailed analyses

  13. 2006 Bethesda International Consensus recommendations on the immunophenotypic analysis of hematolymphoid neoplasia by flow cytometry: optimal reagents and reporting for the flow cytometric diagnosis of hematopoietic neoplasia.

    PubMed

    Wood, Brent L; Arroz, Maria; Barnett, David; DiGiuseppe, Joseph; Greig, Bruce; Kussick, Steven J; Oldaker, Teri; Shenkin, Mark; Stone, Elizabeth; Wallace, Paul

    2007-01-01

    Immunophenotyping by flow cytometry has become standard practice in the evaluation and monitoring of patients with hematopoietic neoplasia. However, despite its widespread use, considerable variability continues to exist in the reagents used for evaluation and the format in which results are reported. As part of the 2006 Bethesda Consensus conference, a committee was formed to attempt to define a consensus set of reagents suitable for general use in the diagnosis and monitoring of hematopoietic neoplasms. The committee included laboratory professionals from private, public, and university hospitals as well as large reference laboratories that routinely operate clinical flow cytometry laboratories with an emphasis on lymphoma and leukemia immunophenotyping. A survey of participants successfully identified the cell lineage(s) to be evaluated for each of a variety of specific medical indications and defined a set of consensus reagents suitable for the initial evaluation of each cell lineage. Elements to be included in the reporting of clinical flow cytometric results for leukemia and lymphoma evaluation were also refined and are comprehensively listed. The 2006 Bethesda Consensus conference represents the first successful attempt to define a set of consensus reagents suitable for the initial evaluation of hematopoietic neoplasia. Copyright 2007 Clinical Cytometry Society.

  14. Flow cytometric analysis of immunoglobulin heavy chain expression in B-cell lymphoma and reactive lymphoid hyperplasia

    PubMed Central

    Grier, David D; Al-Quran, Samer Z; Cardona, Diana M; Li, Ying; Braylan, Raul C

    2012-01-01

    The diagnosis of B-cell lymphoma (BCL) is often dependent on the detection of clonal immunoglobulin (Ig) light chain expression. In some BCLs, the determination of clonality based on Ig light chain restriction may be difficult. The aim of our study was to assess the utility of flow cytometric analysis of surface Ig heavy chain (HC) expression in lymphoid tissues in distinguishing lymphoid hyperplasias from BCLs, and also differentiating various BCL subtypes. HC expression on B-cells varied among different types of hyperplasias. In follicular hyperplasia, IgM and IgD expression was high in mantle cells while germinal center cells showed poor HC expression. In other hyperplasias, B cell compartments were blurred but generally showed high IgD and IgM expression. Compared to hyperplasias, BCLs varied in IgM expression. Small lymphocytic lymphomas had lower IgM expression than mantle cell lymphomas. Of importance, IgD expression was significantly lower in BCLs than in hyperplasias, a finding that can be useful in differentiating lymphoma from reactive processes. PMID:22400070

  15. Flow cytometric kinetic assay of the activity of Na+/H+ antiporter in mammalian cells.

    PubMed

    Dolz, María; O'Connor, José-Enrique; Lequerica, Juan L

    2004-10-01

    The Na(+)/H(+) exchanger (NHE) of mammalian cells is an integral membrane protein that extrudes H(+) ion in exchange for extracellular Na(+) and plays a crucial role in the regulation of intracellular pH (pHi). Thus, when pHi is lowered, NHE extrudes protons at a rate depending of pHi that can be expressed as pH units/s. To abolish the activity of other cellular pH-restoring systems, cells were incubated in bicarbonate-free Dulbecco's modified Eagle's medium buffered with HEPES. Flow cytometry was used to determine pHi with 2',7'-bis-(2-carboxyethyl)-5-(and-6)-carboxyfluorescein acetoxymethyl ester or 5-(and-6)-carboxy SNARF-1 acetoxymethyl ester acetate, and the appropriate fluorescence ratios were measured. The calibration of fluorescence ratios versus pHi was established by using ionophore nigericin. The activity of NHE was calculated by a kinetic flow cytometric assay as the slope at time 0 of the best-fit curve of pHi recovery versus time after intracellular acidification with a pulse of exogenous sodium propionate. The kinetic method allowed determination of the pHi-dependent activity of NHE in cell lines and primary cell cultures. NHE activity values were demonstrated to be up to 0.016 pH units/s within the pHi range of 7.3 to 6.3. The inhibition of NHE activity by the specific inhibitor ethyl isopropyl amiloride was easily detected by this method. The assay conditions can be used to relate variations in pHi with the activity of NHE and provide a standardized method to compare between different cells, inhibitors, models of ischemia by acidification, and other relevant experimental or clinical situations.

  16. Flow cytometric detection of micronuclei by combined staining of DNA and membranes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wessels, J.M.; Nuesse, M.

    1995-03-01

    A new staining method is presented for flow cytometric measurement of micronuclei (MN) in cell cultures and human lymphocytes using membrane-specific fluorescent dyes in addition to DNA staining. Several combinations of fluorescent membrane and DNA dyes were studied for a better discrimination of MN from debris in a suspension of nuclei and micronuclei. For staining of membranes, the lipophilic dyes 2-hydroxyethyl-7,12,17-tris(methoxyethyl)porphycene (HEPn) and 1,6-diphenyl-1,3,5-hexatriene (DPH) were used in combination with ethidium bromide (EB), proflavine (PF), and Hoechst 33258 (HO). Due to their spectral properties, HO or EB combined with HEPn were not as suitable for the discrimination of MN frommore » debris as was HEPn in combination with PF. With HEPn in combination with PF, however, additional noise was found at low fluorescence intensities, probably due to free fluorescent dye molecules in the solution. The optimal simultaneous staining of membranes and DNA was obtained using a combination of DPH and EB. The induction of MN in Chinese hamster and mouse NIH-3T3 cells by UV-B illumination was studied with this new staining technique. UV-B illumination (280-360 nm) induced MN in both cell lines. Chinese hamster cells were found to be more sensitive to these wavelengths. Illumination with wavelengths above 360 nm did not induce MN in either cell line. The results obtained from human lymphocytes using the combination of EB or DPH were comparable to the results obtained with the combination of EB and HO. 23 refs., 7 figs.« less

  17. Automation in high-content flow cytometry screening.

    PubMed

    Naumann, U; Wand, M P

    2009-09-01

    High-content flow cytometric screening (FC-HCS) is a 21st Century technology that combines robotic fluid handling, flow cytometric instrumentation, and bioinformatics software, so that relatively large numbers of flow cytometric samples can be processed and analysed in a short period of time. We revisit a recent application of FC-HCS to the problem of cellular signature definition for acute graft-versus-host-disease. Our focus is on automation of the data processing steps using recent advances in statistical methodology. We demonstrate that effective results, on par with those obtained via manual processing, can be achieved using our automatic techniques. Such automation of FC-HCS has the potential to drastically improve diagnosis and biomarker identification.

  18. CD33 monoclonal antibody conjugated Au cluster nano-bioprobe for targeted flow-cytometric detection of acute myeloid leukaemia

    NASA Astrophysics Data System (ADS)

    Retnakumari, Archana; Jayasimhan, Jasusri; Chandran, Parwathy; Menon, Deepthy; Nair, Shantikumar; Mony, Ullas; Koyakutty, Manzoor

    2011-07-01

    Protein stabilized gold nanoclusters (Au-NCs) are biocompatible, near-infrared (NIR) emitting nanosystems having a wide range of biomedical applications. Here, we report the development of a Au-NC based targeted fluorescent nano-bioprobe for the flow-cytometric detection of acute myeloid leukaemia (AML) cells. Au-NCs with ~ 25-28 atoms showing bright red-NIR fluorescence (600-750 nm) and average size of ~ 0.8 nm were prepared by bovine serum albumin assisted reduction-cum-stabilization in aqueous phase. The protein protected clusters were conjugated with monoclonal antibody against CD33 myeloid antigen, which is overexpressed in ~ 99.2% of the primitive population of AML cells, as confirmed by immunophenotyping using flow cytometry. Au-NC-CD33 conjugates having average size of ~ 12 nm retained bright fluorescence over an extended duration of ~ a year, as the albumin protein protects Au-NCs against degradation. Nanotoxicity studies revealed excellent biocompatibility of Au-NC conjugates, as they showed no adverse effect on the cell viability and inflammatory response. Target specificity of the conjugates for detecting CD33 expressing AML cells (KG1a) in flow cytometry showed specific staining of ~ 95.4% of leukaemia cells within 1-2 h compared to a non-specific uptake of ~ 8.2% in human peripheral blood cells (PBMCs) which are CD33low. The confocal imaging also demonstrated the targeted uptake of CD33 conjugated Au-NCs by leukaemia cells, thus confirming the flow cytometry results. This study demonstrates that novel nano-bioprobes can be developed using protein protected fluorescent nanoclusters of Au for the molecular receptor targeted flow cytometry based detection and imaging of cancer cells.

  19. Japanese Society for Laboratory Hematology flow cytometric reference method of determining the differential leukocyte count: external quality assurance using fresh blood samples.

    PubMed

    Kawai, Y; Nagai, Y; Ogawa, E; Kondo, H

    2017-04-01

    To provide target values for the manufacturers' survey of the Japanese Society for Laboratory Hematology (JSLH), accurate standard data from healthy volunteers were needed for the five-part differential leukocyte count. To obtain such data, JSLH required an antibody panel that achieved high specificity (particularly for mononuclear cells) using simple gating procedures. We developed a flow cytometric method for determining the differential leukocyte count (JSLH-Diff) and validated it by comparison with the flow cytometric differential leukocyte count of the International Council for Standardization in Haematology (ICSH-Diff) and the manual differential count obtained by microscopy (Manual-Diff). First, the reference laboratory performed an imprecision study of JSLH-Diff and ICSH-Diff, as well as performing comparison among JSLH-Diff, Manual-Diff, and ICSH-Diff. Then two reference laboratories and seven participating laboratories performed imprecision and accuracy studies of JSLH-Diff, Manual-Diff, and ICSH-Diff. Simultaneously, six manufacturers' laboratories provided their own representative values by using automated hematology analyzers. The precision of both JSLH-Diff and ICSH-Diff methods was adequate. Comparison by the reference laboratory showed that all correlation coefficients, slopes and intercepts obtained by the JSLH-Diff, ICSH-Diff, and Manual-Diff methods conformed to the criteria. When the imprecision and accuracy of JSLH-Diff were assessed at seven laboratories, the CV% for lymphocytes, neutrophils, monocytes, eosinophils, and basophils was 0.5~0.9%, 0.3~0.7%, 1.7~2.6%, 3.0~7.9%, and 3.8~10.4%, respectively. More than 99% of CD45 positive leukocytes were identified as normal leukocytes by JSLH-Diff. When JSLH-Diff method were validated by comparison with Manual-Diff and ICSH-Diff, JSLH-Diff showed good performance as a reference method. © 2016 John Wiley & Sons Ltd.

  20. Evaluation of flow cytometric HIT assays in relation to an IgG-Specific immunoassay and clinical outcome.

    PubMed

    Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  1. Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients.

    PubMed

    Zhai, Juping; Ding, Mengyuan; Yang, Tianjie; Zuo, Bin; Weng, Zhen; Zhao, Yunxiao; He, Jun; Wu, Qingyu; Ruan, Changgeng; He, Yang

    2017-10-23

    Platelet autoantibody detection is critical for immune thrombocytopenia (ITP) diagnosis and prognosis. Therefore, we aimed to establish a quantitative flow cytometric immunobead assay (FCIA) for ITP platelet autoantibodies evaluation. Capture microbeads coupled with anti-GPIX, -GPIb, -GPIIb, -GPIIIa and P-selectin antibodies were used to bind the platelet-bound autoantibodies complex generated from plasma samples of 250 ITP patients, 163 non-ITP patients and 243 healthy controls, a fluorescein isothiocyanate (FITC)-conjugated secondary antibody was the detector reagent and mean fluorescence intensity (MFI) signals were recorded by flow cytometry. Intra- and inter-assay variations of the quantitative FCIA assay were assessed. Comparisons of the specificity, sensitivity and accuracy between quantitative and qualitative FCIA or monoclonal antibody immobilization of platelet antigen (MAIPA) assay were performed. Finally, treatment process was monitored by our quantitative FCIA in 8 newly diagnosed ITPs. The coefficient of variations (CV) of the quantitative FCIA assay were respectively 9.4, 3.8, 5.4, 5.1 and 5.8% for anti-GPIX, -GPIb, -GPIIIa, -GPIIb and -P-selectin autoantibodies. Elevated levels of autoantibodies against platelet glycoproteins GPIX, GPIb, GPIIIa, GPIIb and P-selectin were detected by our quantitative FCIA in ITP patients compared to non-ITP patients or healthy controls. The sensitivity, specificity and accuracy of our quantitative assay were respectively 73.13, 81.98 and 78.65% when combining all 5 autoantibodies, while the sensitivity, specificity and accuracy of MAIPA assay were respectively 41.46, 90.41 and 72.81%. A quantitative FCIA assay was established. Reduced levels of platelet autoantibodies could be confirmed by our quantitative FCIA in ITP patients after corticosteroid treatment. Our quantitative assay is not only good for ITP diagnosis but also for ITP treatment monitoring.

  2. Simultaneous use of multiplex ligation-dependent probe amplification assay and flow cytometric DNA ploidy analysis in patients with acute leukemia.

    PubMed

    Reyes-Núñez, Virginia; Galo-Hooker, Evelyn; Pérez-Romano, Beatriz; Duque, Ricardo E; Ruiz-Arguelles, Alejandro; Garcés-Eisele, Javier

    2018-01-01

    The aim of this work was to simultaneously use multiplex ligation-dependent probe amplification (MLPA) assay and flow cytometric DNA ploidy analysis (FPA) to detect aneuploidy in patients with newly diagnosed acute leukemia. MLPA assay and propidium iodide FPA were used to test samples from 53 consecutive patients with newly diagnosed acute leukemia referred to our laboratory for immunophenotyping. Results were compared by nonparametric statistics. The combined use of both methods significantly increased the rate of detection of aneuploidy as compared to that obtained by each method alone. The limitations of one method are somehow countervailed by the other and vice versa. MPLA and FPA yield different yet complementary information concerning aneuploidy in acute leukemia. The simultaneous use of both methods might be recommended in the clinical setting. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  3. The importance of platelets in the expression of monocyte tissue factor antigen measured by a new whole blood flow cytometric assay.

    PubMed

    Amirkhosravi, A; Alexander, M; May, K; Francis, D A; Warnes, G; Biggerstaff, J; Francis, J L

    1996-01-01

    Previous methods for the determination of monocyte tissue factor (TF) have been technically complex, difficult to standardize, prone to spuriously elevated results and difficult to implement in a clinical laboratory environment. We report the development of a two-color whole blood cytometric technique that overcomes many of these disadvantages. The assay uses small volumes of citrated blood (1.0 ml), can be performed in under one hour (if endotoxin stimulation is not performed), is reproducible (CV = 5%) and uses methodology commonly available in clinical laboratories. Baseline (mean +/- SD) expression of monocyte TF in normal subjects was very low (1.1 +/- 0.95%, Mean Fluorescence [Mean FL] 0.20 +/- 0.01) making relatively small increases easy to detect. Monocyte TF expression following endotoxin (LPS) stimulation for 1 h was 34.6 +/- 11.2% (Mean FL 0.32 +/- 0.04). LPS-stimulated activity varied between subjects (21-68%) but was remarkably consistent for individual subjects (CV = 5.4%). Stimulated monocyte TF expression was directly proportional to the platelet count and was reduced by platelet protective anticoagulants and by ingestion of aspirin. Non LPS-stimulated monocyte TF was markedly increased, in a dose-dependent manner, by adding collagen to whole blood. This was apparently associated with platelet-monocyte binding and could be abolished by anti-P-Selectin. We conclude that the whole blood flow cytometric assay of monocyte TF may be a valuable tool for clinical use and a useful model system for evaluating the humoral and cellular factors governing monocyte TF expression in a natural environment.

  4. A novel rapid and reproducible flow cytometric method for optimization of transfection efficiency in cells

    PubMed Central

    Homann, Stefanie; Hofmann, Christian; Gorin, Aleksandr M.; Nguyen, Huy Cong Xuan; Huynh, Diana; Hamid, Phillip; Maithel, Neil; Yacoubian, Vahe; Mu, Wenli; Kossyvakis, Athanasios; Sen Roy, Shubhendu; Yang, Otto Orlean

    2017-01-01

    Transfection is one of the most frequently used techniques in molecular biology that is also applicable for gene therapy studies in humans. One of the biggest challenges to investigate the protein function and interaction in gene therapy studies is to have reliable monospecific detection reagents, particularly antibodies, for all human gene products. Thus, a reliable method that can optimize transfection efficiency based on not only expression of the target protein of interest but also the uptake of the nucleic acid plasmid, can be an important tool in molecular biology. Here, we present a simple, rapid and robust flow cytometric method that can be used as a tool to optimize transfection efficiency at the single cell level while overcoming limitations of prior established methods that quantify transfection efficiency. By using optimized ratios of transfection reagent and a nucleic acid (DNA or RNA) vector directly labeled with a fluorochrome, this method can be used as a tool to simultaneously quantify cellular toxicity of different transfection reagents, the amount of nucleic acid plasmid that cells have taken up during transfection as well as the amount of the encoded expressed protein. Finally, we demonstrate that this method is reproducible, can be standardized and can reliably and rapidly quantify transfection efficiency, reducing assay costs and increasing throughput while increasing data robustness. PMID:28863132

  5. Means and methods for cytometric therapies

    DOEpatents

    Gillies, George T.; Fillmore, Helen; Broaddus, William C.; Evans, III, Boyd M.; Allison, Stephen W.

    2013-03-26

    A functionalized tip is incorporated into catheters for the cytometric delivery of cells into the brain and other body parts. For use in the brain, the tip forms part of a neurosurgical probe having a proximal end and a distal end. In addition to the functionalized tip, the probe has at least one cell slurry delivery lumen and a plurality of optical fibers configured along the probe, terminating in the tip to provide the photo-optical capability needed to monitor the viability and physiological behavior of the grafted cells as well as certain characteristics of the cellular environment. Details are also presented of the use of a neurocatheter having a cytometric tip of the type disclosed in the invention, as employed within the context of a feedback and control system for regulating the number of cells delivered to the brain of a patient.

  6. Analytical validation of a flow cytometric protocol for quantification of platelet microparticles in dogs.

    PubMed

    Cremer, Signe E; Krogh, Anne K H; Hedström, Matilda E K; Christiansen, Liselotte B; Tarnow, Inge; Kristensen, Annemarie T

    2018-06-01

    Platelet microparticles (PMPs) are subcellular procoagulant vesicles released upon platelet activation. In people with clinical diseases, alterations in PMP concentrations have been extensively investigated, but few canine studies exist. This study aims to validate a canine flow cytometric protocol for PMP quantification and to assess the influence of calcium on PMP concentrations. Microparticles (MP) were quantified in citrated whole blood (WB) and platelet-poor plasma (PPP) using flow cytometry. Anti-CD61 antibody and Annexin V (AnV) were used to detect platelets and phosphatidylserine, respectively. In 13 healthy dogs, CD61 + /AnV - concentrations were analyzed with/without a calcium buffer. CD61 + /AnV - , CD61 + /AnV + , and CD61 - /AnV + MP quantification were validated in 10 healthy dogs. The coefficient of variation (CV) for duplicate (intra-assay) and parallel (inter-assay) analyses and detection limits (DLs) were calculated. CD61 + /AnV - concentrations were higher in calcium buffer; 841,800 MP/μL (526,000-1,666,200) vs without; 474,200 MP/μL (278,800-997,500), P < .05. In WB, PMP were above DLs and demonstrated acceptable (<20%) intra-assay and inter-assay CVs in 9/10 dogs: 1.7% (0.5-8.9) and 9.0% (0.9-11.9), respectively, for CD61 + /AnV - and 2.4% (0.2-8.7) and 7.8% (0.0-12.8), respectively, for CD61 + /AnV + . Acceptable CVs were not seen for the CD61 - /AnV + MP. In PPP, quantifications were challenged by high inter-assay CV, overlapping DLs and hemolysis and lipemia interfered with quantification in 5/10 dogs. Calcium induced higher in vitro PMP concentrations, likely due to platelet activation. PMP concentrations were reliably quantified in WB, indicating the potential for clinical applications. PPP analyses were unreliable due to high inter-CV and DL overlap, and not obtainable due to hemolysis and lipemia interference. © 2018 American Society for Veterinary Clinical Pathology.

  7. Identification of microbes from the surfaces of food-processing lines based on the flow cytometric evaluation of cellular metabolic activity combined with cell sorting.

    PubMed

    Juzwa, W; Duber, A; Myszka, K; Białas, W; Czaczyk, K

    2016-09-01

    In this study the design of a flow cytometry-based procedure to facilitate the detection of adherent bacteria from food-processing surfaces was evaluated. The measurement of the cellular redox potential (CRP) of microbial cells was combined with cell sorting for the identification of microorganisms. The procedure enhanced live/dead cell discrimination owing to the measurement of the cell physiology. The microbial contamination of the surface of a stainless steel conveyor used to process button mushrooms was evaluated in three independent experiments. The flow cytometry procedure provided a step towards monitoring of contamination and enabled the assessment of microbial food safety hazards by the discrimination of active, mid-active and non-active bacterial sub-populations based on determination of their cellular vitality and subsequently single cell sorting to isolate microbial strains from discriminated sub-populations. There was a significant correlation (r = 0.97; p < 0.05) between the bacterial cell count estimated by the pour plate method and flow cytometry, despite there being differences in the absolute number of cells detected. The combined approach of flow cytometric CRP measurement and cell sorting allowed an in situ analysis of microbial cell vitality and the identification of species from defined sub-populations, although the identified microbes were limited to culturable cells.

  8. Flow cytometric analysis of lymphocyte proliferative responses to food allergens in dogs with food allergy.

    PubMed

    Fujimura, Masato; Masuda, Kenichi; Hayashiya, Makio; Okayama, Taro

    2011-10-01

    Two different allergy tests, antigen-specific immunoglobulin E quantification (IgE test) and flow cytometric analysis of antigen-specific proliferation of peripheral lymphocytes (lymphocyte proliferation test), were performed to examine differences in allergic reactions to food allergens in dogs with food allergy (FA). Thirteen dogs were diagnosed as FA based on clinical findings and elimination diet trials. Seven dogs clinically diagnosed with canine atopic dermatitis (CAD) were used as a disease control group, and 5 healthy dogs were used as a negative control group. In the FA group, 19 and 33 allergen reactions were identified using the serum IgE test and the lymphocyte proliferation test, respectively. Likewise, in the CAD group, 12 and 6 allergen reactions and in the healthy dogs 3 and 0 allergen reactions were identified by each test, respectively. A significant difference was found between FA and healthy dogs in terms of positive allergen detection by the lymphocyte proliferation test, suggesting that the test can be useful to differentiate FA from healthy dogs but not from CAD. Both tests were repeated in 6 of the dogs with FA after a 1.5- to 5-month elimination diet trial. The IgE concentrations in 9 of 11 of the positive reactions decreased by 20-80%, whereas all the positive reactions in the lymphocyte proliferation test decreased to nearly zero (P<0.05), suggesting that lymphocytes against food allergens may be involved in the pathogenesis of canine FA.

  9. Flow Cytometric Analysis of Bimolecular Fluorescence Complementation: A High Throughput Quantitative Method to Study Protein-protein Interaction

    PubMed Central

    Wang, Li; Carnegie, Graeme K.

    2013-01-01

    Among methods to study protein-protein interaction inside cells, Bimolecular Fluorescence Complementation (BiFC) is relatively simple and sensitive. BiFC is based on the production of fluorescence using two non-fluorescent fragments of a fluorescent protein (Venus, a Yellow Fluorescent Protein variant, is used here). Non-fluorescent Venus fragments (VN and VC) are fused to two interacting proteins (in this case, AKAP-Lbc and PDE4D3), yielding fluorescence due to VN-AKAP-Lbc-VC-PDE4D3 interaction and the formation of a functional fluorescent protein inside cells. BiFC provides information on the subcellular localization of protein complexes and the strength of protein interactions based on fluorescence intensity. However, BiFC analysis using microscopy to quantify the strength of protein-protein interaction is time-consuming and somewhat subjective due to heterogeneity in protein expression and interaction. By coupling flow cytometric analysis with BiFC methodology, the fluorescent BiFC protein-protein interaction signal can be accurately measured for a large quantity of cells in a short time. Here, we demonstrate an application of this methodology to map regions in PDE4D3 that are required for the interaction with AKAP-Lbc. This high throughput methodology can be applied to screening factors that regulate protein-protein interaction. PMID:23979513

  10. Flow cytometric analysis of bimolecular fluorescence complementation: a high throughput quantitative method to study protein-protein interaction.

    PubMed

    Wang, Li; Carnegie, Graeme K

    2013-08-15

    Among methods to study protein-protein interaction inside cells, Bimolecular Fluorescence Complementation (BiFC) is relatively simple and sensitive. BiFC is based on the production of fluorescence using two non-fluorescent fragments of a fluorescent protein (Venus, a Yellow Fluorescent Protein variant, is used here). Non-fluorescent Venus fragments (VN and VC) are fused to two interacting proteins (in this case, AKAP-Lbc and PDE4D3), yielding fluorescence due to VN-AKAP-Lbc-VC-PDE4D3 interaction and the formation of a functional fluorescent protein inside cells. BiFC provides information on the subcellular localization of protein complexes and the strength of protein interactions based on fluorescence intensity. However, BiFC analysis using microscopy to quantify the strength of protein-protein interaction is time-consuming and somewhat subjective due to heterogeneity in protein expression and interaction. By coupling flow cytometric analysis with BiFC methodology, the fluorescent BiFC protein-protein interaction signal can be accurately measured for a large quantity of cells in a short time. Here, we demonstrate an application of this methodology to map regions in PDE4D3 that are required for the interaction with AKAP-Lbc. This high throughput methodology can be applied to screening factors that regulate protein-protein interaction.

  11. Flow karyotyping and sorting of human chromosomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, J.W.; Lucas, J.; Peters, D.

    1986-07-16

    Flow cytometry and sorting are becoming increasingly useful as tools for chromosome classfication and for the detection of numerical and structural chromosome aberrations. Chromosomes of a single type can be purified with these tools to facilitate gene mapping or production of chromosome specific recombinant DNA libraries. For analysis of chromosomes with flow cytometry, the chromosomes are extracted from mitotic cells, stained with one or more fluorescent dyes and classified one-by-one according to their dye content(s). Thus, the flow approach is fundamentally different than conventional karyotyping where chromosomes are classified within the context of a metaphase spread. Flow sorting allows purificationmore » of chromosomes that can be distinguished flow cytometrically. The authors describe the basic principles of flow cytometric chromosome classification i.e. flow karyotyping, and chromosome sorting and describe several applications. 30 refs., 8 figs.« less

  12. Relevance of Flow Cytometric Auto-Crossmatch to the Post-transplant Course of Kidney Transplant Recipients.

    PubMed

    Demir, E; Yeğit, O; Erol, A; Akgül, S U; Çalışkan, B; Bayraktar, A; Çalışkan, Y; Türkmen, A; Savran, F O; Sever, M S

    2017-04-01

    The crossmatch test is essential prior to kidney transplantation (tx) to confirm compatibility between the donor and the recipient. However, its results can be misleading due to "undetectable antibodies" in the recipient's serum. To establish if undetectable autoantibodies are responsible for a positive result, an auto-crossmatch test can be performed. In this study, we aim to determine the long-term prognostic value of auto-flow cytometric auto-crossmatch (FCXM) test on kidney survival in kidney tx recipients. The primary outcome variable was reduced renal function. Secondary endpoints were incidence of biopsy-confirmed chronic antibody-mediated rejection (CAMR) and recurrent glomerulonephritis (GN). There were no differences regarding initial serum creatinine levels between the study and control groups (P = .441). Patients who had positive auto-B FCXM had a significantly reduced renal function compared with the control group (P = .016). Four patients developed biopsy-confirmed CAMR in the study group and 1 patient in the control group (P = .047). Five patients had biopsy-confirmed recurrent GN in the GN study group, and only 1 patient had recurrent GN in the GN control group (P = .026). Kidney transplant recipients with positive auto-FCXM test had significantly reduced renal function and a higher incidence of recurrent GN and CAMR compared with the control group. The findings of this study suggest a potential role of auto-antibody causing positive auto-FCXM test result, meanwhile increasing the risk of CAMR, recurrent GN, and new-onset diabetes after tx. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Flow cytometric chemosensitivity assay using JC‑1, a sensor of mitochondrial transmembrane potential, in acute leukemia.

    PubMed

    Yokosuka, Tomoko; Goto, Hiroaki; Fujii, Hisaki; Naruto, Takuya; Takeuchi, Masanobu; Tanoshima, Reo; Kato, Hiromi; Yanagimachi, Masakatsu; Kajiwara, Ryosuke; Yokota, Shumpei

    2013-12-01

    The purpose of the study is to establish a simple and relatively inexpensive flow cytometric chemosensitivity assay (FCCA) for leukemia to distinguish leukemic blasts from normal leukocytes in clinical samples. We first examined whether the FCCA with the mitochondrial membrane depolarization sensor, 5, 50, 6, 60-tetrachloro-1, 10, 3, 30 tetraethyl benzimidazolo carbocyanine iodide (JC-1), could detect drug-induced apoptosis as the conventional FCCA by annexin V/7-AAD detection did and whether it was applicable in the clinical samples. Second, we compared the results of the FCCA for prednisolone (PSL) with clinical PSL response in 18 acute lymphoblastic leukemia (ALL) patients to evaluate the reliability of the JC-1 FCCA. Finally, we performed the JC-1 FCCA for bortezomib (Bor) in 25 ALL or 11 acute myeloid leukemia (AML) samples as the example of the clinical application of the FCCA. In ALL cells, the results of the JC-1 FCCA for nine anticancer drugs were well correlated with those of the conventional FCCA using anti-annexin V antibody (P < 0.001). In the clinical samples from 18 children with ALL, the results of the JC-1 FCCA for PSL were significantly correlated with the clinical PSL response (P = 0.005). In ALL samples, the sensitivity for Bor was found to be significantly correlated with the sensitivity for PSL (P = 0.005). In AML samples, the Bor sensitivity was strongly correlated with the cytarabine sensitivity (P = 0.0003). This study showed the reliability of a relatively simple and the FCCA using JC-1, and the possibility for the further clinical application.

  14. Coexpression of multidrug resistance involve proteins: a flow cytometric analysis.

    PubMed

    Boutonnat, J; Bonnefoix, T; Mousseau, M; Seigneurin, D; Ronot, X

    1998-01-01

    Cross resistance to multiple natural cytotoxic products represents a major obstacle in myeloblastic acute leukaemia (AML). Multidrug resistance (MDR) often involves overexpression of plasma membrane drug transporter P-glycoprotein (PGP) or the resistance associated protein (MRP). Recently, a protein overexpressed in a non-PGP MDR lung cancer cell line and termed lung resistance related protein (LRP) was identified. These proteins are known to be associated with a bad prognosis in AML. We have developed a triple indirect labelling analysed by flow cytometry to detect the coexpression of these proteins. Since no cell line expressing all three antigens is known, we mixed K562 cells (resistant to Adriblastine, PGP+, MRP-, LRP-) with GLC4 cells (resistant to Adriblastine, PGP-, MRP+, LRP+) to create a model system to test the method. The antibodies used were UIC2 for PGP, MRPm6 for MRP and LRP56 for LRP. They were revealed by Fab'2 coupled with Fluoresceine-isothiocyanate, Phycoerythrin or Tricolor with isotype specificity. Cells were fixed and permeabilized after PGP labelling because MRPm6 and LRP56 recognize intracellular epitopes. PGP and LRP were easily detected. MRP is expressed at relatively low levels and was more difficult to detect because in the triple labelling the non specific staining was higher than in a single labelling. Despite the increased background in the triple labelling we were able to detect coexpression of PGP, MRP, LRP by flow cytometry. This method appears to be very useful to detect coexpression of markers in AML. Such coexpression could modify the therapeutic approach with revertants.

  15. High speed flow cytometric separation of viable cells

    DOEpatents

    Sasaki, D.T.; Van den Engh, G.J.; Buckie, A.M.

    1995-11-14

    Hematopoietic cell populations are separated to provide cell sets and subsets as viable cells with high purity and high yields, based on the number of original cells present in the mixture. High-speed flow cytometry is employed using light characteristics of the cells to separate the cells, where high flow speeds are used to reduce the sorting time.

  16. High speed flow cytometric separation of viable cells

    DOEpatents

    Sasaki, Dennis T.; Van den Engh, Gerrit J.; Buckie, Anne-Marie

    1995-01-01

    Hematopoietic cell populations are separated to provide cell sets and subsets as viable cells with high purity and high yields, based on the number of original cells present in the mixture. High-speed flow cytometry is employed using light characteristics of the cells to separate the cells, where high flow speeds are used to reduce the sorting time.

  17. Optimized multiparametric flow cytometric analysis of circulating endothelial cells and their subpopulations in peripheral blood of patients with solid tumors: a technical analysis.

    PubMed

    Zhou, Fangbin; Zhou, Yaying; Yang, Ming; Wen, Jinli; Dong, Jun; Tan, Wenyong

    2018-01-01

    Circulating endothelial cells (CECs) and their subpopulations could be potential novel biomarkers for various malignancies. However, reliable enumerable methods are warranted to further improve their clinical utility. This study aimed to optimize a flow cytometric method (FCM) assay for CECs and subpopulations in peripheral blood for patients with solid cancers. An FCM assay was used to detect and identify CECs. A panel of 60 blood samples, including 44 metastatic cancer patients and 16 healthy controls, were used in this study. Some key issues of CEC enumeration, including sample material and anticoagulant selection, optimal titration of antibodies, lysis/wash procedures of blood sample preparation, conditions of sample storage, sufficient cell events to enhance the signal, fluorescence-minus-one controls instead of isotype controls to reduce background noise, optimal selection of cell surface markers, and evaluating the reproducibility of our method, were integrated and investigated. Wilcoxon and Mann-Whitney U tests were used to determine statistically significant differences. In this validation study, we refined a five-color FCM method to detect CECs and their subpopulations in peripheral blood of patients with solid tumors. Several key technical issues regarding preanalytical elements, FCM data acquisition, and analysis were addressed. Furthermore, we clinically validated the utility of our method. The baseline levels of mature CECs, endothelial progenitor cells, and activated CECs were higher in cancer patients than healthy subjects ( P <0.01). However, there was no significant difference in resting CEC levels between healthy subjects and cancer patients ( P =0.193). We integrated and comprehensively addressed significant technical issues found in previously published assays and validated the reproducibility and sensitivity of our proposed method. Future work is required to explore the potential of our optimized method in clinical oncologic applications.

  18. Flow cytometric sorting of fresh and frozen-thawed spermatozoa in the western lowland gorilla (Gorilla gorilla gorilla).

    PubMed

    O'Brien, J K; Stojanov, T; Crichton, E G; Evans, K M; Leigh, D; Maxwell, W M C; Evans, G; Loskutoff, N M

    2005-08-01

    We adapted flow cytometry technology for high-purity sorting of X chromosome-bearing spermatozoa in the western lowland gorilla (Gorilla gorilla gorilla). Our objectives were to develop methodologies for liquid storage of semen prior to sorting, sorting of liquid-stored and frozen-thawed spermatozoa, and assessment of sorting accuracy. In study 1, the in vitro sperm characteristics of gorilla ejaculates from one male were unchanged (P > 0.05) after 8 hr of liquid storage at 15 degrees C in a non-egg yolk diluent (HEPES-buffered modified Tyrode's medium). In study 2, we examined the efficacy of sorting fresh and frozen-thawed spermatozoa using human spermatozoa as a model for gorilla spermatozoa. Ejaculates from one male were split into fresh and frozen aliquots. X-enriched samples derived from both fresh and frozen-thawed human semen were of high purity, as determined by fluorescence in situ hybridization (FISH; 90.7%+/-2.3%, overall), and contained a high proportion of morphologically normal spermatozoa (86.0%+/-1.0%, overall). In study 3, we processed liquid-stored semen from two gorillas for sorting using a modification of methods for human spermatozoa. The sort rate for enrichment of X-bearing spermatozoa was 7.3+/-2.5 spermatozoa per second. The X-enriched samples were of high purity (single-sperm PCR: 83.7%) and normal morphology (79.0%+/-3.9%). In study 4 we examined frozen-thawed gorilla semen, and the sort rate (8.3+/-2.9 X-bearing sperm/sec), purity (89.7%), and normal morphology (81.4%+/-3.4%) were comparable to those of liquid-stored semen. Depending on the male and the type of sample used (fresh or frozen-thawed), 0.8-2.2% of gorilla spermatozoa in the processed ejaculate were present in the X-enriched sample. These results demonstrate that fresh or frozen-thawed gorilla spermatozoa can be flow cytometrically sorted into samples enriched for X-bearing spermatozoa. Copyright 2005 Wiley-Liss, Inc.

  19. A novel and easy FxCycle™ violet based flow cytometric method for simultaneous assessment of DNA ploidy and six-color immunophenotyping.

    PubMed

    Tembhare, Prashant; Badrinath, Yajamanam; Ghogale, Sitaram; Patkar, Nikhil; Dhole, Nilesh; Dalavi, Pooja; Kunder, Nikesh; Kumar, Ashok; Gujral, Sumeet; Subramanian, P G

    2016-03-01

    Abnormal DNA ploidy is a valuable prognostic factor in many neoplasms, especially in hematological neoplasms like B-cell acute lymphoblastic leukemia (B-ALL) and multiple myeloma (MM). Current methods of flow-cytometric (FC) DNA-ploidy evaluation are either technically difficult or limited to three- to four-color immunophenotyping and hence, challenging to evaluate DNA-ploidy in minute tumor population with background rich of its normal counterpart cells and other hematopoietic cells. We standardized a novel sensitive and easy method of simultaneous evaluation of six- to seven-color immunophenotyping and DNA-ploidy using a dye-FxCycle Violet (FCV). Linearity, resolution, and coefficient of variation (CV) for FCV were studied using chicken erythrocyte nuclei. Ploidy results of FCV were compared with Propidium iodide (PI) in 20 samples and intra-assay variation for FCV was studied. Using this six-color immunophenotyping & FCV-protocol DNA-ploidy was determined in bone-marrow samples from 124 B-ALL & 50 MM patients. Dilution experiment was also conducted to determine the sensitivity in detection of aneuploidy in minute tumor population. FCV revealed high linearity and resolution in 450/50 channel. On comparison with PI, CV of Go/G1-peak with FCV (mean-CV 4.1%) was slightly higher than PI (mean-CV 2.9%) but had complete agreement in ploidy results. Dilution experiment showed that aneuploidy could be accurately detected up to the limit of 0.01% tumor cells. Intra-assay variation was very low with CV of 0.005%. In B-ALL, hypodiploidy was noted in 4%, hyperdiploidy in 24%, near-hyperdiploidy in 13% and remaining 59% were diploid. In MM, hypodiploidy was in 2%, hyperdiploidy in 58%, near-hyperdiploidy in 8% and remaining 30% were diploid. FCV-based DNA-ploidy method is a sensitive and easy method for simultaneous evaluation of six-color immunophenotyping and DNA analysis. It is useful in DNA-ploidy evaluation of minute tumor population in cases like minimal residual

  20. Ground-to-air flow visualization using Solar Calcium-K line Background-Oriented Schlieren

    NASA Astrophysics Data System (ADS)

    Hill, Michael A.; Haering, Edward A.

    2017-01-01

    The Calcium-K Eclipse Background-Oriented Schlieren experiment was performed as a proof of concept test to evaluate the effectiveness of using the solar disk as a background to perform the Background-Oriented Schlieren (BOS) method of flow visualization. A ground-based imaging system was equipped with a Calcium-K line optical etalon filter to enable the use of the chromosphere of the sun as the irregular background to be used for BOS. A US Air Force T-38 aircraft performed three supersonic runs which eclipsed the sun as viewed from the imaging system. The images were successfully post-processed using optical flow methods to qualitatively reveal the density gradients in the flow around the aircraft.

  1. Role of flow-cytometric immunophenotyping in prediction of BCR/ABL1 gene rearrangement in adult B-cell acute lymphoblastic leukemia.

    PubMed

    Corrente, Francesco; Bellesi, Silvia; Metafuni, Elisabetta; Puggioni, Pier Luigi; Marietti, Sara; Ciminello, Angela Maria; Za, Tommaso; Sorà, Federica; Fianchi, Luana; Sica, Simona; De Stefano, Valerio; Chiusolo, Patrizia

    2018-05-01

    We performed a retrospective analysis of 88 adult patients with B-ALL diagnosed in our center by a flow-cytometric assessment. Immunophenotypic expression of leukemic cells was explored by simultaneous evaluation of positivity, percentage of expressing cells and median fluorescence intensity (MFI). BCR/ABL1 fusion transcripts were assessed by RT-PCR analysis and were identified in 36 patients (40.9%). CD10 and CD34 were positive in the totality of BCR/ABL1-positive cases. Patients with gene rearrangement had a greater frequency of CD66c, CD13 and CD33 positivity compared with BCR/ABL1-negative cases. Moreover, BCR/ABL1-positive cases exhibited a greater median percentage and MFI values of CD13, CD33, CD66c, CD10, CD34 and CD25 expressions, but a lower median percentage and MFI values of CD38 and CD22 expressions than patients without gene rearrangement. Multivariate logistic regression analysis showed that CD10, CD38 and CD13 expressions were independent predictors for the presence of BCR/ABL1 rearrangement. Predictive probabilities of molecular occurrence based on these markers are proposed. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  2. Establishing tools for early diagnosis of congenital toxoplasmosis: Flow cytometric IgG avidity assay as a confirmatory test for neonatal screening.

    PubMed

    de Castro Zacche-Tonini, Aline; Fonseca, Giuliana Schmidt França; de Jesus, Laura Néspoli Nassar Pansini; Barros, Geisa Baptista; Coelho-Dos-Reis, Jordana Grazziela Alves; Béla, Samantha Ribeiro; Machado, Anderson Silva; Carneiro, Ana Carolina Aguiar Vasconcelos; Andrade, Gláucia Manzan Queiroz; Vasconcelos-Santos, Daniel Vitor; Januário, José Nélio; Teixeira-Carvalho, Andréa; Vitor, Ricardo Wagner Almeida; Ferro, Eloísa Amália Vieira; Mineo, José Roberto; Martins-Filho, Olindo Assis; Lemos, Elenice Moreira

    2017-12-01

    The aim of this study was to evaluate the performance of conventional serology (Q-Preven™ and ELFAVIDAS™) and flow cytometry-based serologic tools for early serologic diagnosis of congenital toxoplasmosis. The study groups included prospectively confirmed cases of congenital toxoplasmosis (TOXO=88) and age-matching non-infected controls (NI=15).The results demonstrated that all samples tested positive/indeterminate for anti-T. gondii IgM screening at birth using air-dried whole blood samples. Serum samples collected at 30-45days after birth tested positive for ELFAVIDAS™ IgG in both groups. While all NI tested negative for ELFAVIDAS™ IgM and IgA, only 78% and 36% of TOXO tested positive for IgM and IgA, respectively. Flow cytometry-based anti-T. gondii IgM, IgA and IgG reactivity displayed moderate performance with low sensitivity (47.6%, 72.6% and 75.0%, respectively). Regardless the remarkable specificity of IgG1, IgG2 and IgG3 subclasses for early diagnosis, weak or moderate specificity was observed (Se=73.9%, 60.2% and 83.0%, respectively). The analysis of IgG avidity indices (AI) demonstrated the highest performance among the flow cytometry-based methods (Se=96.6%; Sp=93.3%), underscoring the low avidity index (AI<60%) within TOXO (97.0%) in contrast with the high avidity index (AI>60%) in NI (93%). Analysis of anti-T. gondii IgG and IgG3 reactivity for mother:infant paired samples may represent a relevant complementary tests for early diagnosis. In conclusion, a feasible high-standard algorithm (Accuracy=97.1%) was proposed consisting of Q-Preven™ IgM screening at birth, followed by ELFAVIDAS™ IgM and flow cytometric IgG avidity analysis at 30-45days after birth as a high performance tool for early serological diagnosis of congenital toxoplasmosis. Copyright © 2017. Published by Elsevier B.V.

  3. Flow cytometry of duodenal intraepithelial lymphocytes improves diagnosis of celiac disease in difficult cases.

    PubMed

    Valle, Julio; Morgado, José Mario T; Ruiz-Martín, Juan; Guardiola, Antonio; Lopes-Nogueras, Miriam; García-Vela, Almudena; Martín-Sacristán, Beatriz; Sánchez-Muñoz, Laura

    2017-10-01

    Diagnosis of celiac disease is difficult when the combined results of serology and histology are inconclusive. Studies using flow cytometry of intraepithelial lymphocytes (IELs) have found that celiac patients have increased numbers of γδ IELs, along with a decrease in CD3-CD103 + IELs. The objective of this article is to assess the role of flow cytometric analysis of IELs in the diagnosis of celiac disease in difficult cases. A total of 312 patients with suspicion of celiac disease were included in the study. Duodenal biopsy samples were used for histological assessment and for flow cytometric analysis of IELs. In 46 out of 312 cases (14.7%) the combination of serology and histology did not allow the confirmation or exclusion of celiac disease. HLA typing had been performed in 42 of these difficult cases. Taking into account HLA typing and the response to a gluten-free diet, celiac disease was excluded in 30 of these cases and confirmed in the remaining 12. Flow cytometric analysis of IELs allowed a correct diagnosis in 39 out of 42 difficult cases (92.8%) and had a sensitivity of 91.7% (95% CI: 61.5% to 99.8%) and a specificity of 93.3% (95% CI: 77.9% to 99.2%) for the diagnosis of celiac disease in this setting. Flow cytometric analysis of IELs is useful for the diagnosis of celiac disease in difficult cases.

  4. Long-term preservation of Tetraselmis indica (Chlorodendrophyceae, Chlorophyta) for flow cytometric analysis: Influence of fixative and storage temperature.

    PubMed

    Naik, Sangeeta Mahableshwar; Anil, Arga Chandrashekar

    2017-08-01

    Immediate enumeration of phytoplankton is seldom possible. Therefore, fixation and subsequent storage are required for delayed analysis. This study investigated the influence of glutaraldehyde (GA) concentrations (0.25%, 0.5%, and 1%) and storage temperatures (-80°C LN2 , -80°C, -20°C, and 5°C) on Tetraselmis indica for flow cytometric analysis. Cell recovery, granularity, and membrane permeability were independent of GA concentration whereas cell size and chlorophyll autofluorescence were concentration dependent. After an initial cell loss (16-19%), no cell loss was observed when samples were stored at 5°C. Cell recovery was not influenced by storage temperature until 4months but later samples preserved at -80°C LN2 , -80°C, and -20°C resulted in ~41% cell loss. Although maximum cell recovery with minimal effect on cell integrity was obtained at 5°C, autofluorescence was retained better at -80°C LN2 and -80°C. This suggests that in addition to fixative, the choice of storage temperature is equally important. Thus for long-term preservation, especially to retain autofluorescence, the use of lower concentration (0.25%) of GA when stored at a lower temperature (-80°C LN2 and -80°C) while a higher concentration (1%) of GA when stored at a higher temperature (5°C) is recommended. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Deep sequencing and flow cytometric characterization of expanded effector memory CD8+CD57+ T cells frequently reveals T-cell receptor Vβ oligoclonality and CDR3 homology in acquired aplastic anemia.

    PubMed

    Giudice, Valentina; Feng, Xingmin; Lin, Zenghua; Hu, Wei; Zhang, Fanmao; Qiao, Wangmin; Ibanez, Maria Del Pilar Fernandez; Rios, Olga; Young, Neal S

    2018-05-01

    Oligoclonal expansion of CD8 + CD28 - lymphocytes has been considered indirect evidence for a pathogenic immune response in acquired aplastic anemia. A subset of CD8 + CD28 - cells with CD57 expression, termed effector memory cells, is expanded in several immune-mediated diseases and may have a role in immune surveillance. We hypothesized that effector memory CD8 + CD28 - CD57 + cells may drive aberrant oligoclonal expansion in aplastic anemia. We found CD8 + CD57 + cells frequently expanded in the blood of aplastic anemia patients, with oligoclonal characteristics by flow cytometric Vβ usage analysis: skewing in 1-5 Vβ families and frequencies of immunodominant clones ranging from 1.98% to 66.5%. Oligoclonal characteristics were also observed in total CD8 + cells from aplastic anemia patients with CD8 + CD57 + cell expansion by T-cell receptor deep sequencing, as well as the presence of 1-3 immunodominant clones. Oligoclonality was confirmed by T-cell receptor repertoire deep sequencing of enriched CD8 + CD57 + cells, which also showed decreased diversity compared to total CD4 + and CD8 + cell pools. From analysis of complementarity-determining region 3 sequences in the CD8 + cell pool, a total of 29 sequences were shared between patients and controls, but these sequences were highly expressed in aplastic anemia subjects and also present in their immunodominant clones. In summary, expansion of effector memory CD8 + T cells is frequent in aplastic anemia and mirrors Vβ oligoclonal expansion. Flow cytometric Vβ usage analysis combined with deep sequencing technologies allows high resolution characterization of the T-cell receptor repertoire, and might represent a useful tool in the diagnosis and periodic evaluation of aplastic anemia patients. (Registered at clinicaltrials.gov identifiers: 00001620, 01623167, 00001397, 00071045, 00081523, 00961064 ). Copyright © 2018 Ferrata Storti Foundation.

  6. Flow cytometry, morphometry and histopathology as biomarkers of benzo[a]pyrene exposure in brown bullheads (ameiurus nebulosus)

    USGS Publications Warehouse

    Grady, Andrew W.; McLaughlin, Ronald M.; Caldwell, Charles W.; Schmitt, Christopher J.; Stalling, David L.

    1992-01-01

    Brown bullheads were given a single intraperitoneal dose of 0, 5, 25 or 125 mg kg−1 benzo[a]pyrene (BaP), a carcinogenic polycyclic aromatic hydrocarbon, and evaluated over 18 months. Flow cytometric analyses of hepatocyte DNA content indicated an increase in DNA synthesis in BaP-exposed fish prior to day 14 post-exposure. Thereafter, all flow cytometric variables returned to initial levels. Histopathological evaluation of livers from fish sampled at 18 months revealed significant differences among treatments in the amount of hepatic macrophage ceroid pigmentation and basophilic staining intensity. No neoplasms or changes in blood cell DNA content were detected. Significant morphometric variations existed among fish, but differences between sexes overshadowed differences attributable to dose. Flow cytometry yielded no evidence of long-term DNA alterations from a single exposure to BaP; however, the differences detected by DNA analysis shortly after the toxic event suggest that flow cytometric cell cycle analysis may be useful for documenting continuing exposures.

  7. Flow cytometric detection of Pig-A mutant red blood cells using an erythroid-specific antibody: application of the method for evaluating the in vivo genotoxicity of methylphenidate in adolescent rats.

    PubMed

    Dobrovolsky, Vasily N; Boctor, Sherin Y; Twaddle, Nathan C; Doerge, Daniel R; Bishop, Michelle E; Manjanatha, Mugimane G; Kimoto, Takafumi; Miura, Daishiro; Heflich, Robert H; Ferguson, Sherry A

    2010-03-01

    A modified flow cytometry assay for Pig-A mutant rat red blood cells (RBCs) was developed using an antibody that positively identifies rat RBCs (monoclonal antibody HIS49). The assay was used in conjunction with a flow cytometric micronucleus (MN) assay to evaluate gene mutation and clastogenicity/aneugenicity in adolescent male and female rats treated with methylphenidate hydrochloride (MPH). Sprague-Dawley rats were treated orally with 3 mg/kg MPH (70/sex) or water (40/sex) 3 x /day on postnatal days (PNDs) 29-50. Eight additional rats (4/sex) were injected i.p. with N-ethyl-N-nitrosourea (ENU) on PND 28. Blood was collected on PNDs 29, 50, and 90, and used for determining serum MPH levels and/or conducting genotoxicity assays. On the first and last days of MPH treatment (PNDs 29 and 50), serum MPH levels averaged 21 pg/microl, well within the clinical treatment range. Relative to our previously published method (Miura et al. [2008]; Environ Mol Mutagen 49: 614-629), the HIS49 Pig-A mutation assay significantly reduced the background RBC mutant frequency; in the experiments with ENU-treated rats, the modification increased the overall sensitivity of the assay 2-3 fold. Even with the increased assay sensitivity, the 21 consecutive days of MPH treatment produced no evidence of Pig-A mutation induction (measured at PND 90); in addition, MPH treatment did not increase MN frequency (measured at PND 50). These results support the consensus view that the genotoxicity of MPH in pediatric patients reported earlier (El-Zein et al. [2005]: Cancer Lett 230: 284-291) cannot be reproduced in animal models, suggesting that MPH at clinically relevant levels may be nongenotoxic in humans. Published 2009 by Wiley-Liss, Inc.

  8. An enzyme-free flow cytometric bead assay for the sensitive detection of microRNAs based on click nucleic acid ligation-mediated signal amplification.

    PubMed

    Qi, Yan; Qiu, Liying; Fan, Wenjiao; Liu, Chenghui; Li, Zhengping

    2017-08-07

    A versatile flow cytometric bead assay (FCBA) coupled with a completely enzyme-free signal amplification mechanism is developed for the sensitive detection of microRNAs (miRNAs). This new strategy integrates click chemistry-mediated ligation chain reaction (CLCR) with hybridization chain reaction (HCR) for enzyme-free signal amplification on magnetic beads (MBs), and a flow cytometer for the robust fluorescence readout of the MBs. Firstly, target miRNA can initiate CLCR on the surface of MBs based on the click chemical ligation between dibenzocyclooctyne (DBCO)- and azide-modified single-stranded DNA (ssDNA) probes, and the amount of ligated ssDNA sequences on the MBs will be proportional to the dosage of target miRNA. Afterward, each of the ligated ssDNA products can trigger a cascade chain reaction of hybridization events between two alternating fluorophore-tagged hairpin probes, resulting in another signal amplification pathway with an amplified accumulation of fluorophores on the MBs. Finally, the fluorophore-anchored MBs are directly and rapidly analyzed by using a flow cytometer without any separation or elution processes. Herein, the click nucleic acid ligation only occurs on the surface of MBs, so the nonspecific ligations are greatly inhibited compared with that of ligation reaction performed in homogeneous solution. Furthermore, the signal amplification by CLCR-HCR is highly efficient but totally enzyme-free, which may overcome the potential drawbacks of conventional enzyme-catalyzed signal amplification protocols and lead to a high sensitivity. The CLCR-HCR-based FCBA has pushed the detection limit of let-7a miRNA down to the femtomolar (fM) level, showing great potential in miRNA-related biological studies and disease diagnosis.

  9. Flow cytometric HyPer-based assay for hydrogen peroxide.

    PubMed

    Lyublinskaya, O G; Antonov, S A; Gorokhovtsev, S G; Pugovkina, N A; Kornienko, Ju S; Ivanova, Ju S; Shatrova, A N; Aksenov, N D; Zenin, V V; Nikolsky, N N

    2018-05-30

    HyPer is a genetically encoded fluorogenic sensor for hydrogen peroxide which is generally used for the ratiometric imaging of H 2 O 2 fluxes in living cells. Here, we demonstrate the advantages of HyPer-based ratiometric flow cytometry assay for H 2 O 2 , by using K562 and human mesenchymal stem cell lines expressing HyPer. We show that flow cytometry analysis is suitable to detect HyPer response to submicromolar concentrations of extracellularly added H 2 O 2 that is much lower than concentrations addressed previously in the other HyPer-based assays (such as cell imaging or fluorimetry). Suggested technique is also much more sensitive to hydrogen peroxide than the widespread flow cytometry assay exploiting H 2 O 2 -reactive dye H 2 DCFDA and, contrary to the H 2 DCFDA-based assay, can be employed for the kinetic studies of H 2 O 2 utilization by cells, including measurements of the rate constants of H 2 O 2 removal. In addition, flow cytometry multi-parameter ratiometric measurements enable rapid and high-throughput detection of endogenously generated H 2 O 2 in different subpopulations of HyPer-expressing cells. To sum up, HyPer can be used in multi-parameter flow cytometry studies as a highly sensitive indicator of intracellular H 2 O 2 . Copyright © 2018. Published by Elsevier Inc.

  10. Flow cytometry of mammalian sperm: progress in DNA and morphology measurement.

    PubMed

    Pinkel, D; Dean, P; Lake, S; Peters, D; Mendelsohn, M; Gray, J; Van Dilla, M; Gledhill, B

    1979-01-01

    Variability in DNA content and head shape of mammalian sperm are potentially useful markers for flow cytometric monitoring of genetic damage in spermatogenic cells. The high refractive index and extreme flatness of the sperm heads produce an optical effect which interferes with DNA measurements in flow cytometers which have dye excitation and fluorescence light collection normal to the axis of flow. Orientation of sperm in flow controls this effect and results in coefficients of variation of 2.5% and 4.2%, respectively, for DNA measurements of mouse and human sperm. Alternatively, the optical effect can be used to generate shape-related information. Measurements on randomly oriented sperm from three mammalian species using a pair of fluorescence detectors indicate that large shape differences are detectable. Acriflavine-Feulgen stained sperm nuclei are significantly bleached during flow cytometric measurements at power levels routinely used in many flow cytometers. Dual beam studies of this phenomenon indicate it may be useful in detecting abnormally shaped sperm.

  11. Naphthol AS-BI (7-bromo-3-hydroxy-2-naphtho-o-anisidine) phosphatase and naphthol AS-BI. beta. -D-glucuronidase in Chinese hamster ovary cells: biochemical and flow cytometric studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolbeare, F.A.; Phares, W.

    1979-01-01

    Conditions for the biochemical and flow cytometric assay of 7-bromo-3-hydroxy-2-naphtho-o-anisidine phosphatase and ..beta..-D-glucuronidase activities in Chinese hamster ovary cells were studied. In the biochemical assays, the pH optimum for the phosphatase activity was pH 4.6 with a Km of 10/sup -5/ M; the pH optimum for ..beta..-D-glucuronidase activity was pH 5.0 with a Km of 2 x 10/sup -5/ M. For intact cells the derived constants were 3 to 10 times higher. The rate of hydrolysis of both substrates was also examined by flow cytometry. Cellular fluorescence increased linearly for only about 15 min. Diffusion of the fluorescent product probablymore » caused nonlinearity of the fluorescence increase and was demonstrated by mixing cells incubated with substrate with those that had not been incubated. After 15 min, cells that had not been exposed previously to product or substrate contained the fluorescent product. Cells fractionated into size classes by centrifugal elutriation also were analyzed by flow cytometry for ..beta..-D-glucuronidase activity. The activity increased linearly with the increase in cell size corresponding to the progression from G/sub 1/ through S and into G/sub 2/-M phases of the cell cycle.« less

  12. Evaluation of the effect of storage condition on cell extraction and flow cytometric analysis from intestinal biopsies.

    PubMed

    Wildenberg, Manon E; Duijvestein, Marjolijn; Westera, Liset; van Viegen, Tanja; Buskens, Christianne J; van der Bilt, Jarmila D W; Stitt, Larry; Jairath, Vipul; Feagan, Brian G; Vande Casteele, Niels

    2018-06-01

    Flow cytometric (FC) analysis of intestinal tissue biopsies requires prompt cell isolation and processing to prevent cell death and generate valid data. We examined the effect of storage conditions prior to cell isolation and FC on viable cell yield and the proportions of immune cell phenotypes from intestinal biopsies. Biopsies (N = 224) from inflamed or non-inflamed ileal and/or colonic tissue from three patients with Crohn's disease were processed and analyzed immediately in duplicate, or stored under different conditions. Cells were isolated and stained for specific markers, followed by FC. Decreased mean live CD45+ cell counts were observed after storage of biopsies at -80 °C dimethyl sulfoxide (DMSO)/citrate buffer compared with immediate processing (1794.3 vs. 19,672.7; p = 0.006]). A non-significant decrease in CD45+ live cell count occurred after storage at -20 °C in DMSO/citrate buffer and cell yield was adequate for subsequent analysis. CD3+ cell proportions were significantly lower after storage at 4 °C in complete medium for 48 h compared with immediate analysis. Mean CD14+ cell proportions were significantly higher after storage of biopsies at -80 °C in DMSO/citrate buffer compared with immediate analysis (2.61% vs. 1.31%, p = 0.007). CD4+, CD8+ and CD4+/CD8+ cell proportions were unaffected by storage condition. Storage of intestinal tissue biopsies at -20 °C in DMSO/citrate buffer for up to 48 h resulted in sufficient viable cell yield for FC analysis without affecting subsequent marker-positive cell proportions. These findings support the potential shipping and storage of intestinal biopsies for centralized FC analysis in multicenter clinical trials. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Systematic misestimation of cell subpopulations by flow cytometry: a mathematical analysis.

    PubMed

    Petrunkina, A M; Harrison, R A P

    2010-04-15

    Various sources of variability in flow cytometric determination of cell concentration have previously been investigated with respect to andrologic applications. Although common aspects related to the variation between samples, variation between operators, and accuracy have been extensively studied, specific sources of false-count estimation have found less attention. In particular, a major and well-recognized source of misestimation of cell counts (i.e., contamination of the sample by non-sperm particles) has not to date been characterized in detail. We show here by means of original mathematical research that not only the cell counts but also the percentages of cells expressing different fluorescence patterns are affected by the presence of alien particles often neglected in studies involving flow cytometric characterization. We demonstrate that there is a systematic overestimation in the proportion of unstained (viable) cells detected by flow cytometry in cases where the non-sperm particles are not excluded from analysis by additional identification other than light-scatter characteristics. Moreover, we provide an exact mathematical estimate for the magnitude of this overestimation, and we discuss the consequences for diagnostic applications and studies on sperm physiology, specifically for studies on sperm capacitation and evaluation of cryopreserved semen. Finally, equations are derived for the correction of the flow cytometric values for use in practical applications. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Induction and disappearance of thymine dimers in human skin exposed to UVB radiation: flow cytometric measurements in replicating and nonreplicating epidermal cells.

    PubMed

    Berg, R J; de Bueger, S C; Guikers, K; van Weelden, H; van Vloten, W A; van der Leun, J C; de Gruijl, F R

    1995-12-01

    We have earlier reported on determining UV-induced DNA damage in murine epidermal cell suspensions by flow cytometric analysis of the fluorescence from a fluorescein isothiocyanate-labeled antibody (H3) directed against thymine dimers (T < > T). Here we present an optimization of the technique for analysis of epidermal cell suspensions from 4 mm biopsies from human skin. Cells with different DNA contents can easily be distinguished in flow cytometry by the intensity of DNA-specific 7-amino-actinomycin D fluorescence. Genuine G2-M-phase cells can further be distinguished from cell doublets by pulse-shape discrimination. Thus, T < > T levels in individual cells with different DNA contents (i.e. G0-G1, S or G2-M phases) can be determined after in vivo exposure of human skin to environmentally relevant UVB (280-315 nm) doses. The method was applied to measure the decrease of T < > T in nonreplicating cells (G0-G1 phase) and replicating cells (S phase or G2-M phase) from seven volunteers exposed to twice their minimal erythema dose. The reduction in the average T < > T-specific fluorescence at 24 h after exposure was 46% (ranging between 16% and 66%) for the G0-G1 cells and 70% (ranging between 37% and 100%) for the S + G2-M cells. The difference was statistically highly significant. Determination of individual DNA repair capacities with this method can become a convenient diagnostic tool for patients with DNA repair disorders, or it may even be used to identify individuals with low repair proficiencies and increased risk of developing skin cancers.

  15. Optical Flow for Flight and Wind Tunnel Background Oriented Schlieren Imaging

    NASA Technical Reports Server (NTRS)

    Smith, Nathanial T.; Heineck, James T.; Schairer, Edward T.

    2017-01-01

    Background oriented Schlieren images have historically been generated by calculating the observed pixel displacement between a wind-on and wind-o image pair using normalized cross-correlation. This work uses optical flow to solve the displacement fields which generate the Schlieren images. A well established method used in the computer vision community, optical flow is the apparent motion in an image sequence due to brightness changes. The regularization method of Horn and Schunck is used to create Schlieren images using two data sets: a supersonic jet plume shock interaction from the NASA Ames Unitary Plan Wind Tunnel, and a transonic flight test of a T-38 aircraft using a naturally occurring background, performed in conjunction with NASA Ames and Armstrong Research Centers. Results are presented and contrasted with those using normalized cross-correlation. The optical flow Schlieren images are found to provided significantly more detail. We apply the method to historical data sets to demonstrate the broad applicability and limitations of the technique.

  16. Genotoxic Mode of Action Predictions from a Multiplexed Flow Cytometric Assay and a Machine Learning Approach

    PubMed Central

    Bryce, Steven M.; Bernacki, Derek T.; Bemis, Jeffrey C.; Dertinger, Stephen D.

    2015-01-01

    Several endpoints associated with cellular responses to DNA damage as well as overt cytotoxicity were multiplexed into a miniaturized, “add and read” type flow cytometric assay. Reagents included a detergent to liberate nuclei, propidium iodide and RNase to serve as a pan-DNA dye, fluorescent antibodies against γH2AX, phospho-histone H3, and p53, and fluorescent microspheres for absolute nuclei counts. The assay was applied to TK6 cells and 67 diverse reference chemicals that served as a training set. Exposure was for 24 hrs in 96 well plates, and unless precipitation or foreknowledge about cytotoxicity suggested otherwise, the highest concentration was 1 mM. At 4 and 24 hrs aliquots were removed and added to microtiter plates containing the reagent mix. Following a brief incubation period robotic sampling facilitated walk-away data acquisition. Univariate analyses identified biomarkers and time points that were valuable for classifying agents into one of three groups: clastogenic, aneugenic, or non-genotoxic. These mode of action predictions were optimized with a forward-stepping process that considered Wald test p-values, receiver operator characteristic curves, and pseudo R2 values, among others. A particularly high performing multinomial logistic regression model was comprised of four factors: 4hr γH2AX and phospho-histone H3 values, and 24 hr p53 and polyploidy values. For the training set chemicals, the four-factor model resulted in 94% concordance with our a priori classifications. Cross validation occurred via a leave-one-out approach, and in this case 91% concordance was observed. A test set of 17 chemicals that were not used to construct the model were evaluated, some of which utilized a short-term treatment in the presence of a metabolic activation system, and in 16 cases mode of action was correctly predicted. These initial results are encouraging as they suggest a machine learning strategy can be used to rapidly and reliably predict new

  17. Genotoxic mode of action predictions from a multiplexed flow cytometric assay and a machine learning approach.

    PubMed

    Bryce, Steven M; Bernacki, Derek T; Bemis, Jeffrey C; Dertinger, Stephen D

    2016-04-01

    Several endpoints associated with cellular responses to DNA damage as well as overt cytotoxicity were multiplexed into a miniaturized, "add and read" type flow cytometric assay. Reagents included a detergent to liberate nuclei, RNase and propidium iodide to serve as a pan-DNA dye, fluorescent antibodies against γH2AX, phospho-histone H3, and p53, and fluorescent microspheres for absolute nuclei counts. The assay was applied to TK6 cells and 67 diverse reference chemicals that served as a training set. Exposure was for 24 hrs in 96-well plates, and unless precipitation or foreknowledge about cytotoxicity suggested otherwise, the highest concentration was 1 mM. At 4- and 24-hrs aliquots were removed and added to microtiter plates containing the reagent mix. Following a brief incubation period robotic sampling facilitated walk-away data acquisition. Univariate analyses identified biomarkers and time points that were valuable for classifying agents into one of three groups: clastogenic, aneugenic, or non-genotoxic. These mode of action predictions were optimized with a forward-stepping process that considered Wald test p-values, receiver operator characteristic curves, and pseudo R(2) values, among others. A particularly high performing multinomial logistic regression model was comprised of four factors: 4 hr γH2AX and phospho-histone H3 values, and 24 hr p53 and polyploidy values. For the training set chemicals, the four-factor model resulted in 94% concordance with our a priori classifications. Cross validation occurred via a leave-one-out approach, and in this case 91% concordance was observed. A test set of 17 chemicals that were not used to construct the model were evaluated, some of which utilized a short-term treatment in the presence of a metabolic activation system, and in 16 cases mode of action was correctly predicted. These initial results are encouraging as they suggest a machine learning strategy can be used to rapidly and reliably predict new chemicals

  18. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi, Shanavaz [Livermore, CA; Langlois, Richard G [Livermore, CA; Venkateswaran, Kodumudi S [Round Rock, TX

    2011-07-05

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

  19. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi, Shanavaz [Livermore, CA; Langlois, Richard G [Livermore, CA; Venkateswaran, Kodumudi S [Livermore, CA

    2006-08-01

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM, on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA, on the 5' end.

  20. The Effect of Uniform Background Flow on Vortex Ring Formation and Pinch-off

    NASA Astrophysics Data System (ADS)

    Krueger, Paul S.; Dabiri, John O.; Gharib, Morteza

    2002-11-01

    Experimental investigations of vortex ring formation are extended to include the effects of a uniform background flow, in a manner relevant to the locomotion of aquatic animals utilizing jet propulsion. Gharib et. al. [J. Fluid Mech. 360, 121 (1998)] generated vortex rings using a piston/cylinder apparatus with relatively large discharge times to demonstrate that the vortex ring at the leading edge of the jet attains its maximum circulation at a piston stroke-to-diameter ratio L/D of 4. This "formation number" is robust over a range of piston motions and cylinder boundary conditions, and can be explained in terms of the Kelvin-Benjamin variational principle. To determine the effect of background flow on formation number and pinch-off of the leading vortex ring, uniform co-flow is established in a large annulus surrounding the vortex generator. The ratio of co-flow velocity to piston velocity is varied between 0 and 1. In addition, the co-flow is initiated at times both before and after the start of vortex ring formation. We present results for stroke ratios L/D = 2 and L/D = 8, in order to discern effects of the co-flow on the leading vortex ring in isolation and in the presence of a trailing jet.

  1. Cr(VI) induces DNA damage, cell cycle arrest and polyploidization: a flow cytometric and comet assay study in Pisum sativum.

    PubMed

    Rodriguez, Eleazar; Azevedo, Raquel; Fernandes, Pedro; Santos, Conceição

    2011-07-18

    Chromium(VI) is recognized as the most toxic valency of Cr, but its genotoxicity and cytostaticity in plants is still poorly studied. In order to analyze Cr(VI) cyto- and gentotoxicity, Pisum sativum L. plants were grown in soil and watered with solutions with different concentrations of Cr up to 2000 mg/L. After 28 days of exposure, leaves showed no significant variations in either cell cycle dynamics or ploidy level. As for DNA damage, flow cytometric (FCM) histograms showed significant differences in full peak coefficient of variation (FPCV) values, suggesting clastogenicity. This is paralleled by the Comet assay results, showing an increase in DNA damage for 1000 and 2000 mg/L. In roots, exposure to 2000 mg/L resulted in cell cycle arrest at the G(2)/M checkpoint. It was also verified that under the same conditions 40% of the individuals analyzed suffered polyploidization having both 2C and 4C levels. DNA damage analysis by the Comet assay and FCM revealed dose-dependent increases in DNA damage and FPCV. Through this, we have unequivocally demonstrated for the first time in plants that Cr exposure can result in DNA damage, cell cycle arrest, and polyploidization. Moreover, we critically compare the validity of the Comet assay and FCM in evaluating cytogenetic toxicity tests in plants and demonstrate that the data provided by both techniques complement each other and present high correlation levels. In conclusion, the data presented provides new insight on Cr effects in plants in general and supports the use of the parameters tested in this study as reliable endpoints for this metal toxicity in plants. © 2011 American Chemical Society

  2. Numerical Simulation of Vortex Ring Formation in the Presence of Background Flow: Implications for Squid Propulsion

    NASA Astrophysics Data System (ADS)

    Jiang, Houshuo; Grosenbaugh, Mark A.

    2002-11-01

    Numerical simulations are used to study the laminar vortex ring formation in the presence of background flow. The numerical setup includes a round-headed axisymmetric body with a sharp-wedged opening at the posterior end where a column of fluid is pushed out by a piston inside the body. The piston motion is explicitly included into the simulations by using a deforming mesh. The numerical method is verified by simulating the standard vortex ring formation process in quiescent fluid for a wide range of piston stroke to cylinder diameter ratios (Lm/D). The results from these simulations confirm the existence of a universal formation time scale (formation number) found by others from experimental and numerical studies. For the case of vortex ring formation by the piston/cylinder arrangement in a constant background flow (i.e. the background flow is in the direction of the piston motion), the results show that a smaller fraction of the ejected circulation is delivered into the leading vortex ring, thereby decreasing the formation number. The mechanism behind this reduction is believed to be related to the modification of the shear layer profile between the jet flow and the background flow by the external boundary layer on the outer surface of the cylinder. In effect, the vorticity in the jet is cancelled by the opposite signed vorticity in the external boundary layer. Simulations using different end geometries confirm the general nature of the phenomenon. The thrust generated from the jet and the drag forces acting on the body are calculated with and without background flow for different piston programs. The implications of these results for squid propulsion are discussed.

  3. Bacterial screening by flow cytometry offers potential for extension of platelet storage: results of 14 months of active surveillance.

    PubMed

    Vollmer, T; Engemann, J; Kleesiek, K; Dreier, J

    2011-06-01

    Bacterial contamination is currently the major infectious hazard of platelet transfusion in developed countries. It has been demonstrated that a significant transfusion risk remains, in particular with older platelet concentrates (PCs). In 2009, the shelf life of PCs was therefore reduced in Germany to 4 days after the day of production according to Vote 38. The aim of the present study was the application and implementation of a recently developed flow cytometry-based rapid screening method (BactiFlow) for bacterial contamination at the end of PC shelf life as a routine in-process control. A total of 472 apheresis-derived PCs were tested using the BactiFlow flow cytometric assay to detect and count bacteria based on esterase activity in viable bacterial cells, while the BacT/Alert automated culture system served as the reference method. The automation potential of the flow cytometric assay was analysed by applying the semi-automated BactiFlow ALS system. An algorithm was developed for use in routine blood bank operations to extend the storage period of PCs. Two of the 472 apheresis PCs tested were positive in culture and identified as Propionibacterium species. One PC was positive for Staphylococcus aureus by both methods. All remaining specimens were tested negative by both methods. Our study demonstrates that routine bacterial testing of PCs was successfully implemented and the established algorithm proved efficient. The BactiFlow flow cytometric assay is the first rapid screening method which is suitable for a routine application combined with a high sensitivity. © 2011 The Authors. Transfusion Medicine © 2011 British Blood Transfusion Society.

  4. Optimization of flow cytometric detection and cell sorting of transgenic Plasmodium parasites using interchangeable optical filters

    PubMed Central

    2012-01-01

    Background Malaria remains a major cause of morbidity and mortality worldwide. Flow cytometry-based assays that take advantage of fluorescent protein (FP)-expressing malaria parasites have proven to be valuable tools for quantification and sorting of specific subpopulations of parasite-infected red blood cells. However, identification of rare subpopulations of parasites using green fluorescent protein (GFP) labelling is complicated by autofluorescence (AF) of red blood cells and low signal from transgenic parasites. It has been suggested that cell sorting yield could be improved by using filters that precisely match the emission spectrum of GFP. Methods Detection of transgenic Plasmodium falciparum parasites expressing either tdTomato or GFP was performed using a flow cytometer with interchangeable optical filters. Parasitaemia was evaluated using different optical filters and, after optimization of optics, the GFP-expressing parasites were sorted and analysed by microscopy after cytospin preparation and by imaging cytometry. Results A new approach to evaluate filter performance in flow cytometry using two-dimensional dot blot was developed. By selecting optical filters with narrow bandpass (BP) and maximum position of filter emission close to GFP maximum emission in the FL1 channel (510/20, 512/20 and 517/20; dichroics 502LP and 466LP), AF was markedly decreased and signal-background improve dramatically. Sorting of GFP-expressing parasite populations in infected red blood cells at 90 or 95% purity with these filters resulted in 50-150% increased yield when compared to the standard filter set-up. The purity of the sorted population was confirmed using imaging cytometry and microscopy of cytospin preparations of sorted red blood cells infected with transgenic malaria parasites. Discussion Filter optimization is particularly important for applications where the FP signal and percentage of positive events are relatively low, such as analysis of parasite

  5. Flow cytometric discrimination of seven lineage markers by using two fluorochromes

    PubMed Central

    Boin, Francesco; Giardino Torchia, Maria Letizia; Borrello, Ivan; Noonan, Kimberly A.; Neil, Matthew; Soloski, Mark J.

    2017-01-01

    Flow cytometry is the primary immunological technique used to analyze multiple parameters on complex cell populations. We present a staining method that identifies major human mononuclear lymphoid and myeloid populations (CD4+ and CD8+ T cells, γδ T cells, B cells, NK cells and monocytes), using only two fluorochromes and a minimal number of cells. Our approach increases the number of markers recordable on most flow cytometers allowing for a deeper and more comprehensive immunophenotyping. PMID:29190813

  6. Automated flow cytometric analysis across large numbers of samples and cell types.

    PubMed

    Chen, Xiaoyi; Hasan, Milena; Libri, Valentina; Urrutia, Alejandra; Beitz, Benoît; Rouilly, Vincent; Duffy, Darragh; Patin, Étienne; Chalmond, Bernard; Rogge, Lars; Quintana-Murci, Lluis; Albert, Matthew L; Schwikowski, Benno

    2015-04-01

    Multi-parametric flow cytometry is a key technology for characterization of immune cell phenotypes. However, robust high-dimensional post-analytic strategies for automated data analysis in large numbers of donors are still lacking. Here, we report a computational pipeline, called FlowGM, which minimizes operator input, is insensitive to compensation settings, and can be adapted to different analytic panels. A Gaussian Mixture Model (GMM)-based approach was utilized for initial clustering, with the number of clusters determined using Bayesian Information Criterion. Meta-clustering in a reference donor permitted automated identification of 24 cell types across four panels. Cluster labels were integrated into FCS files, thus permitting comparisons to manual gating. Cell numbers and coefficient of variation (CV) were similar between FlowGM and conventional gating for lymphocyte populations, but notably FlowGM provided improved discrimination of "hard-to-gate" monocyte and dendritic cell (DC) subsets. FlowGM thus provides rapid high-dimensional analysis of cell phenotypes and is amenable to cohort studies. Copyright © 2015. Published by Elsevier Inc.

  7. An efficient and rapid transgenic pollen screening and detection method using flow cytometry.

    PubMed

    Moon, Hong S; Eda, Shigetoshi; Saxton, Arnold M; Ow, David W; Stewart, C Neal

    2011-01-01

    Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.

  8. In-vitro immunosuppression of canine T-lymphocyte-specific proliferation with dexamethasone, cyclosporine, and the active metabolites of azathioprine and leflunomide in a flow-cytometric assay

    PubMed Central

    Nafe, Laura A.; Dodam, John R.; Reinero, Carol R.

    2014-01-01

    A high rate of mortality, expense, and complications of immunosuppressive therapy in dogs underscores the need for optimization of drug dosing. The purpose of this study was to determine, using a flow-cytometric assay, the 50% T-cell inhibitory concentration (IC50) of dexamethasone, cyclosporine, and the active metabolites of azathioprine (6-mercaptopurine) and leflunomide (A77 1726) in canine lymphocytes stimulated with concanavalin A (Con A). Whole blood was collected from 5 privately owned, healthy dogs of various ages, genders, and breeds. Peripheral blood mononuclear cells, obtained by density-gradient separation, were cultured for 72 h with Con A, a fluorochrome-tagged cell proliferation dye, and various concentrations of dexamethasone (0.1, 1, 10, 100, 1000, and 10 000 μM), cyclosporine (0.2, 2, 10, 20, 30, 40, 80, and 200 ng/mL), 6-mercaptopurine (0.5, 2.5, 50, 100, 250, and 500 μM), and A77 1726 (1, 5, 10, 25, 50, and 200 μM). After incubation, the lymphocytes were labeled with propidium iodide and an antibody against canine CD5, a pan T-cell surface marker. Flow cytometry determined the percentage of live, proliferating T-lymphocytes incubated with or without immunosuppressants. The mean (± standard error) IC50 was 3460 ± 1900 μM for dexamethasone, 15.8 ± 2.3 ng/mL for cyclosporine, 1.3 ± 0.4 μM for 6-mercaptopurine, and 55.6 ± 22.0 μM for A77 1722. Inhibition of T-cell proliferation by the 4 immunosuppressants was demonstrated in a concentration-dependent manner, with variability between the dogs. These results represent the initial steps to tailor this assay for individual immunosuppressant protocols for dogs with immune-mediated disease. PMID:24982547

  9. Supercontinuum white light lasers for flow cytometry

    PubMed Central

    Telford, William G.; Subach, Fedor V.; Verkhusha, Vladislav V.

    2009-01-01

    Excitation of fluorescent probes for flow cytometry has traditionally been limited to a few discrete laser lines, an inherent limitation in our ability to excite the vast array of fluorescent probes available for cellular analysis. In this report, we have used a supercontinuum (SC) white light laser as an excitation source for flow cytometry. By selectively filtering the wavelength of interest, almost any laser wavelength in the visible spectrum can be separated and used for flow cytometric analysis. The white light lasers used in this study were integrated into a commercial flow cytometry platform, and a series of high-transmission bandpass filters used to select wavelength ranges from the blue (~480 nm) to the long red (>700 nm). Cells labeled with a variety of fluorescent probes or expressing fluorescent proteins were then analyzed, in comparison with traditional lasers emitting at wavelengths similar to the filtered SC source. Based on a standard sensitivity metric, the white light laser bandwidths produced similar excitation levels to traditional lasers for a wide variety of fluorescent probes and expressible proteins. Sensitivity assessment using fluorescent bead arrays confirmed that the SC laser and traditional sources resulted in similar levels of detection sensitivity. Supercontinuum white light laser sources therefore have the potential to remove a significant barrier in flow cytometric analysis, namely the limitation of excitation wavelengths. Almost any visible wavelength range can be made available for excitation, allowing access to virtually any fluorescent probe, and permitting “fine-tuning” of excitation wavelength to particular probes. PMID:19072836

  10. Flow Cytometric and Cytokine ELISpot Approaches To Characterize the Cell-Mediated Immune Response in Ferrets following Influenza Virus Infection

    PubMed Central

    DiPiazza, Anthony; Richards, Katherine; Batarse, Frances; Lockard, Laura; Zeng, Hui; García-Sastre, Adolfo; Albrecht, Randy A.

    2016-01-01

    ABSTRACT Influenza virus infections represent a significant socioeconomic and public health burden worldwide. Although ferrets are considered by many to be ideal for modeling human responses to influenza infection and vaccination, efforts to understand the cellular immune response have been severely hampered by a paucity of standardized procedures and reagents. In this study, we developed flow cytometric and T cell enzyme-linked immunosorbent spot (ELISpot) approaches to characterize the leukocyte composition and antigen-specific T cell response within key lymphoid tissues following influenza virus infection in ferrets. Through a newly designed and implemented set of serological reagents, we used multiparameter flow cytometry to directly quantify the frequency of CD4+ and CD8+ T cells, Ig+ B cells, CD11b+ myeloid-derived cells, and major histocompatibility complex (MHC) class II-positive antigen-presenting cells (APCs) both prior to and after intranasal infection with A/California/04/09 (H1N1). We found that the leukocyte composition was altered at 10 days postinfection, with notable gains in the frequency of T cells and myeloid cells within the draining lymph node. Furthermore, these studies revealed that the antigen specificity of influenza virus-reactive CD4 and CD8 T cells was very broad, with recognition of the viral HA, NA, M1, NS1, and NP proteins, and that total reactivity to influenza virus postinfection represented approximately 0.1% of the circulating peripheral blood mononuclear cells (PBMC). Finally, we observed distinct patterns of reactivity between individual animals, suggesting heterogeneity at the MHC locus in ferrets within commercial populations, a finding of considerable interest in efforts to move the ferret model forward for influenza vaccine and challenge studies. IMPORTANCE Ferrets are an ideal animal model to study transmission, diseases, and vaccine efficacies of respiratory viruses because of their close anatomical and physiological

  11. Flow cytometric cell cycle analysis of muscle precursor cells cultured within 3D scaffolds in a perfusion bioreactor.

    PubMed

    Flaibani, Marina; Luni, Camilla; Sbalchiero, Elisa; Elvassore, Nicola

    2009-01-01

    It has been widely demonstrated that perfusion bioreactors improve in vitro three-dimensional (3D) cultures in terms of high cell density and uniformity of cell distribution; however, the studies reported in literature were primarily based on qualitative analysis (histology, immunofluorescent staining) or on quantitative data averaged on the whole population (DNA assay, PCR). Studies on the behavior, in terms of cell cycle, of a cell population growing in 3D scaffolds in static or dynamic conditions are still absent. In this work, a perfusion bioreactor suitable to culture C(2)C(12) muscle precursor cells within 3D porous collagen scaffolds was designed and developed and a method based on flowcytometric analyses for analyzing the cell cycle in the cell population was established. Cells were extracted by enzymatic digestion of the collagen scaffolds after 4, 7, and 10 days of culture, and flow cytometric live/dead and cell cycle analyses were performed with Propidium Iodide. A live/dead assay was used for validating the method for cell extraction and staining. Moreover, to investigate spatial heterogeneity of the cell population under perfusion conditions, two stacked scaffolds in the 3D domain, of which only the upstream layer was seeded, were analyzed separately. All results were compared with those obtained from static 3D cultures. The live/dead assay revealed the presence of less than 20% of dead cells, which did not affect the cell cycle analysis. Cell cycle analyses highlighted the increment of cell fractions in proliferating phases (S/G(2)/M) owing to medium perfusion in long-term cultures. After 7-10 days, the percentage of proliferating cells was 8-12% for dynamic cultures and 3-5% for the static controls. A higher fraction of proliferating cells was detected in the downstream scaffold. From a general perspective, this method provided data with a small standard deviation and detected the differences between static and dynamic cultures and between upper and

  12. Fluorescence lifetime measurements in flow cytometry

    NASA Astrophysics Data System (ADS)

    Beisker, Wolfgang; Klocke, Axel

    1997-05-01

    Fluorescence lifetime measurements provide insights int eh dynamic and structural properties of dyes and their micro- environment. The implementation of fluorescence lifetime measurements in flow cytometric systems allows to monitor large cell and particle populations with high statistical significance. In our system, a modulated laser beam is used for excitation and the phase shift of the fluorescence signal recorded with a fast computer controlled digital oscilloscope is processed digitally to determine the phase shift with respect to a reference beam by fast fourier transform. Total fluorescence intensity as well as other parameters can be determined simultaneously from the same fluorescence signal. We use the epi-illumination design to allow the use of high numerical apertures to collect as much light as possible to ensure detection of even weak fluorescence. Data storage and processing is done comparable to slit-scan flow cytometric data using data analysis system. The results are stored, displayed, combined with other parameters and analyzed as normal listmode data. In our report we discuss carefully the signal to noise ratio for analog and digital processed lifetime signals to evaluate the theoretical minimum fluorescence intensity for lifetime measurements. Applications to be presented include DNA staining, parameters of cell functions as well as different applications in non-mammalian cells such as algae.

  13. Flow cytometric single cell analysis reveals heterogeneity between adipose depots

    PubMed Central

    Boumelhem, Badwi B.; Assinder, Stephen J.; Bell-Anderson, Kim S.; Fraser, Stuart T.

    2017-01-01

    ABSTRACT Understanding adipose tissue heterogeneity is hindered by the paucity of methods to analyze mature adipocytes at the single cell level. Here, we report a system for analyzing live adipocytes from different adipose depots in the adult mouse. Single cell suspensions of buoyant adipocytes were separated from the stromal vascular fraction and analyzed by flow cytometry. Compared to other lipophilic dyes, Nile Red uptake effectively distinguished adipocyte populations. Nile Red fluorescence increased with adipocyte size and granularity and could be combined with MitoTracker® Deep Red or fluorescent antibody labeling to further dissect adipose populations. Epicardial adipocytes exhibited the least mitochondrial membrane depolarization and highest fatty-acid translocase CD36 surface expression. In contrast, brown adipocytes showed low surface CD36 expression. Pregnancy resulted in reduced mitochondrial membrane depolarisation and increased CD36 surface expression in brown and epicardial adipocyte populations respectively. Our protocol revealed unreported heterogeneity between adipose depots and highlights the utility of flow cytometry for screening adipocytes at the single cell level. PMID:28453382

  14. Background Oriented Schlieren (BOS) and other Flow Visualization Developments and Applications at GRC

    NASA Technical Reports Server (NTRS)

    Clem, Michelle; Woike, Mark

    2013-01-01

    This is a presentation to be given at an internal NASA Advanced Schlieren Working Group Meeting. The presentation will cover the recent developments and applications of flow visualization methods at GRC. The topics being discussed will include the use of Background Oriented Schlieren (BOS) in the study of screech and its associated shock spacing as well as in the investigation of broadband shock noise reduction in the Jet-Surface Interaction Tests. In addition, other flow visualiztion methods will be discussed in an on-going study comparing schlieren, shadowgraph, BOS, and focusing schlieren.

  15. Genome-size variation in switchgrass (Panicum virgatum): flow cytometry and cytology reveal rampant aneuploidy

    USDA-ARS?s Scientific Manuscript database

    Switchgrass (Panicum virgatum L.), a native perennial dominant of the prairies of North America, has been targeted as a model herbaceous species for biofeedstock development. A flow-cytometric survey of a core set of 11 primarily upland polyploid switchgrass accessions indicated that there was con...

  16. Flow cytometric analysis of platelet cyclooxygenase-1 and -2 and surface glycoproteins in patients with immune thrombocytopenia and healthy individuals.

    PubMed

    Rubak, Peter; Kristensen, Steen D; Hvas, Anne-Mette

    2017-06-01

    Immature platelets may contain more platelet enzymes such as cyclooxygenase (COX)-1 and COX-2 than mature platelets. Patients with immune thrombocytopenia (ITP) have a higher fraction of immature platelets and can therefore be utilized as a biological model for investigating COX-1 and COX-2 platelet expression. The aims were to develop flow cytometric assays for platelet COX-1 and COX-2 and to investigate the COX-1 and COX-2 platelet expression, platelet turnover, and platelet glycoproteins in ITP patients (n = 10) compared with healthy individuals (n = 30). Platelet count and platelet turnover parameters (mean platelet volume (MPV), immature platelet fraction (IPF), and immature platelet count (IPC)) were measured by flow cytometry (Sysmex XE-5000). Platelet COX-1, COX-2, and the glycoproteins (GP)IIb, IX, Ib, Ia, and IIIa were all analyzed by flow cytometry (Navios) and expressed as median fluorescence intensity. COX analyses were performed in both whole blood and platelet rich plasma (PRP), whereas platelet glycoproteins were analyzed in whole blood only. ITP patients had significantly lower platelet count (55 × 10 9 /L) than healthy individuals (240 × 10 9 /L, p < 0.01), but a higher MPV (p = 0.03) and IPF (p < 0.01). IPC was similar for the two groups (p = 0.74). PRP had significantly lower MPV (p < 0.01) and significantly higher platelet count and IPC (both p-values <0.03) when compared with whole blood. IPF was similar for PRP and whole blood (p = 0.18). COX-1 expression was 10 times higher and COX-2 expression was 50% higher in PRP than in whole blood (p COX-1 < 0.01, p COX-2 < 0.01). Platelet COX-1 expression was higher in ITP patients than healthy individuals using whole blood (p COX-1 < 0.01) and PRP, though this was nonsignificant in PRP (p COX-1 = 0.17). In ITP patients, positive correlations were found between platelet turnover and COX-1 expression (all p-values <0.01, rho = 0.80-0.94), whereas healthy individuals showed significant though weaker

  17. Flow cytometric measurement of total DNA and incorporated halodeoxyuridine

    DOEpatents

    Dolbeare, F.A.; Gray, J.W.

    1983-10-18

    A method for the simultaneous flow cylometric measurement of total cellular DNA content and of the uptake of DNA precursors as a measure of DNA synthesis during various phases of the cell cycle in normal and malignant cells in vitro and in vivo is described. The method comprises reacting cells with labelled halodeoxyuridine (HdU), partially denaturing cellular DNA, adding to the reaction medium monoclonal antibodies (mabs) reactive with HdU, reacting the bound mabs with a second labelled antibody, incubating the mixture with a DNA stain, and measuring simultaneously the intensity of the DNA stain as a measure of the total cellular DNA and the HdU incorporated as a measure of DNA synthesis. (ACR)

  18. Challenges of flow-cytometric estimation of nuclear genome size in orchids, a plant group with both whole-genome and progressively partial endoreplication.

    PubMed

    Trávníček, Pavel; Ponert, Jan; Urfus, Tomáš; Jersáková, Jana; Vrána, Jan; Hřibová, Eva; Doležel, Jaroslav; Suda, Jan

    2015-10-01

    Nuclear genome size is an inherited quantitative trait of eukaryotic organisms with both practical and biological consequences. A detailed analysis of major families is a promising approach to fully understand the biological meaning of the extensive variation in genome size in plants. Although Orchidaceae accounts for ∼10% of the angiosperm diversity, the knowledge of patterns and dynamics of their genome size is limited, in part due to difficulties in flow cytometric analyses. Cells in various somatic tissues of orchids undergo extensive endoreplication, either whole-genome or partial, and the G1-phase nuclei with 2C DNA amounts may be lacking, resulting in overestimated genome size values. Interpretation of DNA content histograms is particularly challenging in species with progressively partial endoreplication, in which the ratios between the positions of two neighboring DNA peaks are lower than two. In order to assess distributions of nuclear DNA amounts and identify tissue suitable for reliable estimation of nuclear DNA content, we analyzed six different tissue types in 48 orchid species belonging to all recognized subfamilies. Although traditionally used leaves may provide incorrect C-values, particularly in species with progressively partial endoreplication, young ovaries and pollinaria consistently yield 2C and 1C peaks of their G1-phase nuclei, respectively, and are, therefore, the most suitable parts for genome size studies in orchids. We also provide new DNA C-values for 22 orchid genera and 42 species. Adhering to the proposed methodology would allow for reliable genome size estimates in this largest plant family. Although our research was limited to orchids, the need to find a suitable tissue with dominant 2C peak of G1-phase nuclei applies to all endopolyploid species. © 2015 International Society for Advancement of Cytometry.

  19. Feeding currents of the upside down jellyfish in the presence of background flow.

    PubMed

    Hamlet, Christina L; Miller, Laura A

    2012-11-01

    The upside-down jellyfish (Cassiopea spp.) is an ideal organism for examining feeding and exchange currents generated by bell pulsations due to its relatively sessile nature. Previous experiments and numerical simulations have shown that the oral arms play an important role in directing new fluid into the bell from along the substrate. All of this work, however, has considered the jellyfish in the absence of background flow, but the natural environments of Cassiopea and other cnidarians are dynamic. Flow velocities and directions fluctuate on multiple time scales, and mechanisms of particle capture may be fundamentally different in moving fluids. In this paper, the immersed boundary method is used to simulate a simplified jellyfish in flow. The elaborate oral arm structure is modeled as a homogenous porous layer. The results show that the oral arms trap vortices as they form during contraction and expansion of the bell. For constant flow conditions, the vortices are directed gently across the oral arms where particle capture occurs. For variable direction flows, the secondary structures change the overall pattern of the flow around the bell and appear to stabilize regions of mixing around the secondary mouths.

  20. Flow Cytometric and Cytokine ELISpot Approaches To Characterize the Cell-Mediated Immune Response in Ferrets following Influenza Virus Infection.

    PubMed

    DiPiazza, Anthony; Richards, Katherine; Batarse, Frances; Lockard, Laura; Zeng, Hui; García-Sastre, Adolfo; Albrecht, Randy A; Sant, Andrea J

    2016-09-01

    Influenza virus infections represent a significant socioeconomic and public health burden worldwide. Although ferrets are considered by many to be ideal for modeling human responses to influenza infection and vaccination, efforts to understand the cellular immune response have been severely hampered by a paucity of standardized procedures and reagents. In this study, we developed flow cytometric and T cell enzyme-linked immunosorbent spot (ELISpot) approaches to characterize the leukocyte composition and antigen-specific T cell response within key lymphoid tissues following influenza virus infection in ferrets. Through a newly designed and implemented set of serological reagents, we used multiparameter flow cytometry to directly quantify the frequency of CD4(+) and CD8(+) T cells, Ig(+) B cells, CD11b(+) myeloid-derived cells, and major histocompatibility complex (MHC) class II-positive antigen-presenting cells (APCs) both prior to and after intranasal infection with A/California/04/09 (H1N1). We found that the leukocyte composition was altered at 10 days postinfection, with notable gains in the frequency of T cells and myeloid cells within the draining lymph node. Furthermore, these studies revealed that the antigen specificity of influenza virus-reactive CD4 and CD8 T cells was very broad, with recognition of the viral HA, NA, M1, NS1, and NP proteins, and that total reactivity to influenza virus postinfection represented approximately 0.1% of the circulating peripheral blood mononuclear cells (PBMC). Finally, we observed distinct patterns of reactivity between individual animals, suggesting heterogeneity at the MHC locus in ferrets within commercial populations, a finding of considerable interest in efforts to move the ferret model forward for influenza vaccine and challenge studies. Ferrets are an ideal animal model to study transmission, diseases, and vaccine efficacies of respiratory viruses because of their close anatomical and physiological resemblances to

  1. NASA Langley Low Speed Aeroacoustic Wind Tunnel: Background Noise and Flow Survey Results Prior to FY05 Construction of Facilities Modifications

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Henderson, Brenda S.

    2005-01-01

    The NASA Langley Research Center Low Speed Aeroacoustic Wind Tunnel is a premier facility for model-scale testing of jet noise reduction concepts at realistic flow conditions. However, flow inside the open jet test section is less than optimum. A Construction of Facilities project, scheduled for FY 05, will replace the flow collector with a new design intended to reduce recirculation in the open jet test section. The reduction of recirculation will reduce background noise levels measured by a microphone array impinged by the recirculation flow and will improve flow characteristics in the open jet tunnel flow. In order to assess the degree to which this modification is successful, background noise levels and tunnel flow are documented, in order to establish a baseline, in this report.

  2. Image and flow cytometric analysis of gold nanoparticle uptake by macrophages

    NASA Astrophysics Data System (ADS)

    Fixler, Dror; Ankri, Rinat; Weiss, Ronald; Grahnert, Anja; Melzer, Susanne; Tárnok, Attila

    2016-03-01

    Background/Aim: In atherosclerosis stable and vulnerable atherosclerotic plaque types are distinguished that behave differently concerning rupture, thrombosis and clinical events. The stable are rich in M2 macrophages. The unstable are rich in inflammatory M1 macrophages and are highly susceptible to rupture, setting patients at risk for thrombotic events when they undergo invasive diagnosis such as coronary angiography. Therefore, novel approaches for non-invasive detection and classification of vulnerable plaques in vivo are needed. Whereas classical approaches fail to differentiate between both plaque types, a new biophotonic method (combination of the diffusion reflection (DR) method with flow cytometry (FCM) or image cytometry (IC)) to analyze gold nanoparticle (GNP) loading of plaques could overcome this limitation. Methods: Two types of GNP were used three variants of gold nanorods (GNRI with 40x18 nm, II 65x25 nm and III 52x13 nm in size) and gold nanospheres (GNS with an average diameter of 18.5 nm). The GNS had an absorption peak at 520 nm and the GNR at 630 nm. Monocytes were isolated from human buffy blood samples, differentiated into macrophages and their subtypes and labelled with GNR and GNS for 3 and 24 h. GNS and GNR loading were determined by FCM and/or IC. Macrophages within tissue-like phantoms were analyzed by the DR system. Results: After GNR labelling of macrophages the FCM light scatter values increased up to 3.7 fold and the DR slope changed from an average slope of 0.196 (macrophages only) to an average slope of 0.827 (macrophages labelled with GNR). But, GNRIII did not present much higher DR slopes than the control phantoms, indicating that macrophages take up GNRIII in a lower amount than GNRI or II. IC and microscopy showed that all particle variants were taken up by the cells in a heterogeneous fashion. Conclusion and outlook: The combination of FCM and DR measurements provides a potential novel, highly sensitive and non

  3. Rapid flow cytometric measurement of protein inclusions and nuclear trafficking

    PubMed Central

    Whiten, D. R.; San Gil, R.; McAlary, L.; Yerbury, J. J.; Ecroyd, H.; Wilson, M. R.

    2016-01-01

    Proteinaceous cytoplasmic inclusions are an indicator of dysfunction in normal cellular proteostasis and a hallmark of many neurodegenerative diseases. We describe a simple and rapid new flow cytometry-based method to enumerate, characterise and, if desired, physically recover protein inclusions from cells. This technique can analyse and resolve a broad variety of inclusions differing in both size and protein composition, making it applicable to essentially any model of intracellular protein aggregation. The method also allows rapid quantification of the nuclear trafficking of fluorescently labelled molecules. PMID:27516358

  4. Analysis of synthetic and biological microparticles on several flow cytometric platforms

    EPA Science Inventory

    Microparticles (MPs) are membrane vesicles (0.1 to 1 urn) released from cells upon activation. The limit of detection ofmost standard flow cytometers is just below 1 urn. Recent advances enable detection of particles lower than 0.5 urn, Synthetic. beads are used to define size ra...

  5. Using cosmic microwave background radiation analysis tools for flow anisotropies in relativistic heavy-ion collisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mishra, Ananta P.; Mohapatra, Ranjita K.; Saumia, P. S.

    2010-03-15

    Recently we have shown that there are crucial similarities in the physics of cosmic microwave background radiation (CMBR) anisotropies and the flow anisotropies in relativistic heavy-ion collision experiments (RHICE). We also argued that, following CMBR anisotropy analysis, a plot of root-mean-square values of the flow coefficients, calculated in a laboratory-fixed frame for RHICE, can yield important information about the nature of initial state anisotropies and their evolution. Here we demonstrate the strength of this technique by showing that elliptic flow for noncentral collisions can be directly determined from such a plot without any need for the determination of the eventmore » plane.« less

  6. EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols

    PubMed Central

    Kalina, T; Flores-Montero, J; van der Velden, V H J; Martin-Ayuso, M; Böttcher, S; Ritgen, M; Almeida, J; Lhermitte, L; Asnafi, V; Mendonça, A; de Tute, R; Cullen, M; Sedek, L; Vidriales, M B; Pérez, J J; te Marvelde, J G; Mejstrikova, E; Hrusak, O; Szczepański, T; van Dongen, J J M; Orfao, A

    2012-01-01

    The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database. PMID:22948490

  7. Quantitation of nanoparticle accumulation in flow using optimized microfluidic chambers

    PubMed Central

    Kusunose, J.; Gagnon, M. K. J.; Seo, J. W.; Ferrara, K. W.

    2014-01-01

    Background The vascular cell adhesion molecule-1 (VCAM-1) targeting peptide sequence, VHPKQHR, is a promising moiety for targeting atherosclerosis through incorporation into nanoparticles such as dendrimers and liposomes. Purpose We aim to develop VCAM-1-targeted nanoparticles that effectively accumulate on the endothelium under shear conditions and to develop robust microfluidic chambers able to house sufficient cells for flow cytometric measurements. Methods Carboxyfluorescein-labeled monomeric VHP-peptide, tetrameric VHP-dendrimers (bisbidentate or radial architecture, with or without N-terminal acetylation) and VHP-peptide liposomes were prepared. Human umbilical vein endothelial cells were treated with nano-particles under 0 or 2.9 dyne/cm2 shear, and particle binding was quantified. Flow chambers cured at various temperatures, with or without glass backings were fabricated, characterized for deformation and applied in experiments. Results Although liposomes accumulated with highest efficiency, dendrimers also demonstrated specific binding. N-terminal acetylation significantly reduced dendrimer binding, and despite shorter movement range, bisbidentate dendrimers outperformed radial dendrimers, suggesting multiple epitope presence within its estimated arm-span of 57 Å. Under shear, while liposome binding increased 300%, dendrimer binding to cells decreased 65%. Through higher temperature curing and glass backing insertion, polydimethylsiloxane flow chambers maintaining rectangular cross-section with aspect-ratio as low as 1:111 were achieved. Conclusion Optimized dendrimers and liposomal nanocarriers specifically accumulated onto cells within microfluidic chambers. PMID:24079404

  8. Inhibition of recombinase polymerase amplification by background DNA: a lateral flow-based method for enriching target DNA.

    PubMed

    Rohrman, Brittany; Richards-Kortum, Rebecca

    2015-02-03

    Recombinase polymerase amplification (RPA) may be used to detect a variety of pathogens, often after minimal sample preparation. However, previous work has shown that whole blood inhibits RPA. In this paper, we show that the concentrations of background DNA found in whole blood prevent the amplification of target DNA by RPA. First, using an HIV-1 RPA assay with known concentrations of nonspecific background DNA, we show that RPA tolerates more background DNA when higher HIV-1 target concentrations are present. Then, using three additional assays, we demonstrate that the maximum amount of background DNA that may be tolerated in RPA reactions depends on the DNA sequences used in the assay. We also show that changing the RPA reaction conditions, such as incubation time and primer concentration, has little effect on the ability of RPA to function when high concentrations of background DNA are present. Finally, we develop and characterize a lateral flow-based method for enriching the target DNA concentration relative to the background DNA concentration. This sample processing method enables RPA of 10(4) copies of HIV-1 DNA in a background of 0-14 μg of background DNA. Without lateral flow sample enrichment, the maximum amount of background DNA tolerated is 2 μg when 10(6) copies of HIV-1 DNA are present. This method requires no heating or other external equipment, may be integrated with upstream DNA extraction and purification processes, is compatible with the components of lysed blood, and has the potential to detect HIV-1 DNA in infant whole blood with high proviral loads.

  9. Identifying the Presence of Prostate Cancer in Individuals with PSA Levels <20 ng ml-1 Using Computational Data Extraction Analysis of High Dimensional Peripheral Blood Flow Cytometric Phenotyping Data.

    PubMed

    Cosma, Georgina; McArdle, Stéphanie E; Reeder, Stephen; Foulds, Gemma A; Hood, Simon; Khan, Masood; Pockley, A Graham

    2017-01-01

    Determining whether an asymptomatic individual with Prostate-Specific Antigen (PSA) levels below 20 ng ml -1 has prostate cancer in the absence of definitive, biopsy-based evidence continues to present a significant challenge to clinicians who must decide whether such individuals with low PSA values have prostate cancer. Herein, we present an advanced computational data extraction approach which can identify the presence of prostate cancer in men with PSA levels <20 ng ml -1 on the basis of peripheral blood immune cell profiles that have been generated using multi-parameter flow cytometry. Statistical analysis of immune phenotyping datasets relating to the presence and prevalence of key leukocyte populations in the peripheral blood, as generated from individuals undergoing routine tests for prostate cancer (including tissue biopsy) using multi-parametric flow cytometric analysis, was unable to identify significant relationships between leukocyte population profiles and the presence of benign disease (no prostate cancer) or prostate cancer. By contrast, a Genetic Algorithm computational approach identified a subset of five flow cytometry features ( CD 8 + CD 45 RA - CD 27 - CD 28 - ( CD 8 + Effector Memory cells); CD 4 + CD 45 RA - CD 27 - CD 28 - ( CD 4 + Terminally Differentiated Effector Memory Cells re-expressing CD45RA); CD 3 - CD 19 + (B cells); CD 3 + CD 56 + CD 8 + CD 4 + (NKT cells)) from a set of twenty features, which could potentially discriminate between benign disease and prostate cancer. These features were used to construct a prostate cancer prediction model using the k-Nearest-Neighbor classification algorithm. The proposed model, which takes as input the set of flow cytometry features, outperformed the predictive model which takes PSA values as input. Specifically, the flow cytometry-based model achieved Accuracy = 83.33%, AUC = 83.40%, and optimal ROC points of FPR = 16.13%, TPR = 82.93%, whereas the PSA-based model achieved

  10. DNA flow cytometry of human spermatozoa: consistent stoichiometric staining of sperm DNA using a novel decondensation protocol.

    PubMed

    Kovács, Tamás; Békési, Gyöngyi; Fábián, Akos; Rákosy, Zsuzsa; Horváth, Gábor; Mátyus, László; Balázs, Margit; Jenei, Attila

    2008-10-01

    Rapid flow cytometric measurement of the frequency of aneuploid human sperms is in increasing demand but development of an exploitable method is hindered by difficulties of stoichiometric staining of sperm DNA. An aggressive decondensation protocol is needed after which cell integrity still remains intact. We used flow cytometry to examine the effect of lithium diiodosalicylate (LIS, chaotropic agent) on fluorescence intensity of propidium iodide-treated human spermatozoa from 10 normozoospermic men. When flow cytometric identification of diploid spermatozoa was achieved, validation was performed after sorting by three-color FISH. In contrast with the extremely variable histograms of nondecondensed sperms, consistent identification of haploid and diploid spermatozoa was possible if samples were decondensed with LIS prior to flow cytometry. A 76-fold enrichment of diploid sperms was observed in the sorted fractions by FISH. A significant correlation was found between the proportion of sorted cells and of diploid sperms by FISH. Application of LIS during the preparation of sperm for flow cytometry appears to ensure the stoichiometric staining of sperm DNA, making quantification of aneuploid sperm percentage possible. To our knowledge this is the first report in terms of separating spermatozoa with confirmedly abnormal chromosomal content. High correlation between the proportion of cells identified as having double DNA content by flow cytometry and diploid sperm by FISH allows rapid calculation of diploidy rate. Copyright 2008 International Society for Advancement of Cytometry.

  11. Instability of the roll-streak structure induced by background turbulence in pretransitional Couette flow

    NASA Astrophysics Data System (ADS)

    Farrell, Brian F.; Ioannou, Petros J.; Nikolaidis, Marios-Andreas

    2017-03-01

    Although the roll-streak structure is ubiquitous in both observations and simulations of pretransitional wall-bounded shear flow, this structure is linearly stable if the idealization of laminar flow is made. Lacking an instability, the large transient growth of the roll-streak structure has been invoked to explain its appearance as resulting from chance occurrence in the background turbulence of perturbations configured to optimally excite it. However, there is an alternative interpretation for the role of free-stream turbulence in the genesis of the roll-streak structure, which is that the background turbulence interacts with the roll-streak structure to destabilize it. Statistical state dynamics (SSD) provides analysis methods for studying instabilities of this type that arise from interaction between the coherent and incoherent components of turbulence. SSD in the form of a closure at second order is used in this work to analyze the cooperative eigenmodes arising from interaction between the coherent streamwise invariant component and the incoherent background component of turbulence. In pretransitional Couette flow a manifold of stable modes with roll-streak form is found to exist in the presence of low-intensity background turbulence. The least stable mode of this manifold is destabilized at a critical value of a parameter controlling the background turbulence intensity and a finite-amplitude roll-streak structure arises from this instability through a bifurcation in this parameter. Although this bifurcation has analytical expression only in the infinite ensemble formulation of second order SSD, referred in this work as the S3T system, it is closely reflected in numerical simulations of both the dynamically similar quasilinear system, referred to as the restricted nonlinear (RNL) system, as well as in the full Navier-Stokes equations. This correspondence is verified using ensemble implementations of the RNL system and the Navier-Stokes equations. The S3T

  12. Flow Cytometric Determination of Panton-Valentine Leucocidin S Component Binding

    PubMed Central

    Gauduchon, Valérie; Werner, Sandra; Prévost, Gilles; Monteil, Henri; Colin, Didier A.

    2001-01-01

    The binding of the S component (LukS-PV) from the bicomponent staphylococcal Panton-Valentine leucocidin to human polymorphonuclear neutrophils (PMNs) and monocytes was determined using flow cytometry and a single-cysteine substitution mutant of LukS-PV. The mutant was engineered by replacing a glycine at position 10 with a cysteine and was labeled with a fluorescein moiety. The biological activity of the mutant was identical to that of the native protein. It has been shown that LukS-PV has a high affinity for PMNs (Kd = 0.07 ± 0.02 nM, n = 5) and monocytes (Kd = 0.020 ± 0.003 nM, n = 3) with maximal binding capacities of 197,000 and 80,000 LukS-PV molecules per cell, respectively. The nonspecifically bound molecules of LukS-PV do not form pores in the presence of the F component (LukF-PV) of leucocidin. LukS-PV and HlgC share the same receptor on PMNs, but the S components of other staphylococcal leukotoxins, HlgA, LukE, and LukM, do not compete with LukS-PV for its receptor. Extracellular Ca2+ at physiological concentrations (1 to 2 nM) has only a slight influence on the LukS-PV binding, in contrast to its complete inhibition by Zn2+. The down-regulation by phorbol 12-myristate 13-acetate (PMA) of the binding of LukS-PV was blocked by staurosporine, suggesting that the regulatory effect of PMA depends on protein kinase C activation. The labeled mutant form of LukS-PV has proved very useful for detailed binding studies of circulating white cells by flow cytometry. LukS-PV possesses a high specific affinity for a unique receptor on PMNs and monocytes. PMID:11254598

  13. Flow cytometric characterization of tumor-associated macrophages in experimental gliomas.

    PubMed

    Badie, B; Schartner, J M

    2000-04-01

    Although microglia have been suggested to be a component of the inflammatory reaction to tumors of the central nervous system, their role in glioma biology remains unknown. One obstacle to studying the function of microglia is the inability to effectively separate them from macrophages. Because flow cytometry can effectively discern immune cells with similar surface antigens, we evaluated its role in characterizing the mononuclear cell infiltration in experimental gliomas. Freshly prepared rat C6, 9L, and RG-2 tumor specimens were labeled ex vivo with monoclonal antibodies against CD11b/c, CD45, and CD8a antigens and analyzed by flow cytometry. The extent of microglia (CD11b/c(high), CD45(low)), macrophage (CD11b/c(high), CD45(high)), and lymphocyte (CD11b/c(negative), CD45(high)) infiltration into tumors, tumor periphery, and contralateral tumor-free hemispheres was measured for each glioma type. Microglia, which accounted for 13 to 34% of viable cells, were distributed throughout the central nervous system and were present in the tumors, tumor periphery, and contralateral tumor-free hemispheres. In contrast, macrophages were less prominent within the tumors and tumor periphery (4.2-12%) and were scarce in the contralateral tumor-free hemispheres (0.9-1.1%). Among the tumor types, RG-2 gliomas had the least microglia/macrophage infiltration. The frequency and the distribution pattern of lymphocytes also varied among tumor models. Whereas lymphocytes accounted for more than one-third of the cells in C6 and 9L tumors, they represented only 1% of cells in RG-2 gliomas. More abundant than macrophages and scattered throughout the central nervous system, microglia account for a significant component of the inflammatory response to experimental gliomas. A better understanding of microglial function in gliomas may be important in the development of immunotherapy strategies.

  14. Cytometric Approach for Detection of Encephalitozoon intestinalis, an Emergent Agent▿

    PubMed Central

    Barbosa, Joana; Rodrigues, Acácio Gonçalves; Pina-Vaz, Cidália

    2009-01-01

    Encephalitozoon intestinalis is responsible for intestinal disease in patients with AIDS and immunocompetent patients. The infectious form is a small spore that is resistant to water treatment procedures. Its detection is very important, but detection is very cumbersome and time-consuming. Our main objective was to develop and optimize a specific flow cytometric (FC) protocol for the detection of E. intestinalis in hospital tap water and human feces. To determine the optimal specific antibody (Microspor-FA) concentration, a known concentration of E. intestinalis spores (Waterborne, Inc.) was suspended in hospital tap water and stool specimens with different concentrations of Microspor-FA, and the tap water and stool specimens were incubated under different conditions. The sensitivity limit and specificity were also evaluated. To study spore infectivity, double staining with propidium iodide (PI) and Microspor-FA was undertaken. Distinct approaches for filtration and centrifugation of the stool specimens were used. E. intestinalis spores stained with 10 μg/ml of Microspor-FA at 25°C overnight provided the best results. The detection limit was 5 × 104 spores/ml, and good specificity was demonstrated. Simultaneous staining with Microspor-FA and PI ensured that the E. intestinalis spores were dead and therefore noninfectious. With the stool specimens, better spore recovery was observed with a saturated solution of NaCl and centrifugation at 1,500 × g for 15 min. A new approach for the detection of E. intestinalis from tap water or human feces that ensures that the spores are not viable is now available and represents an important step for the prevention of this threat to public health. PMID:19439525

  15. Flow cytometry of sputum: assessing inflammation and immune response elements in the bronchial airways

    PubMed Central

    Lay, John C.; Peden, David B.; Alexis, Neil E.

    2012-01-01

    Background The evaluation of sputum leukocytes by flow cytometry is an opportunity to assess characteristics of cells residing in the central airways, yet it is hampered by certain inherent properties of sputum including mucus and large amounts of contaminating cells and debris. Objective To develop a gating strategy based on specific antibody panels in combination with light scatter properties for flow cytometric evaluation of sputum cells. Methods Healthy and mild asthmatic volunteers underwent sputum induction. Manually selected mucus “plug” material was treated with dithiothrietol, filtered and total leukocytes acquired. Multicolor flow cytometry was performed using specific gating strategies based on light scatter properties, differential expression of CD45 and cell lineage markers to discriminate leukocytes from squamous epithelial cells and debris. Results The combination of forward scatter and CD45 expression reliably segregated sputum leukocytes from contaminating squamous epithelial cells and debris. Overlap of major leukocyte populations (neutrophils, macrophages/monocytes) required the use of specific antibodies (e.g. CD16, CD64, CD14, HLA-DR) that differentiated granulocytes from monocytes and macrophages. These gating strategies allowed identification of small populations of eosinophils, CD11c+ myeloid dendritic cells, B cells and NK cells. Conclusions Multicolor flow cytometry can be successfully applied to sputum samples to identify and characterize leukocyte populations residing on the surfaces of the central airways. PMID:21639708

  16. Background noise measurements from jet exit vanes designed to reduced flow pulsations in an open-jet wind tunnel

    NASA Technical Reports Server (NTRS)

    Hoad, D. R.; Martin, R. M.

    1985-01-01

    Many open jet wind tunnels experience pulsations of the flow which are typically characterized by periodic low frequency velocity and pressure variations. One method of reducing these fluctuations is to install vanes around the perimeter of the jet exit to protrude into the flow. Although these vanes were shown to be effective in reducing the fluctuation content, they can also increase the test section background noise level. The results of an experimental acoustic program in the Langley 4- by 7-Meter Tunnel is presented which evaluates the effect on tunnel background noise of such modifications to the jet exit nozzle. Noise levels for the baseline tunnel configuration are compared with those for three jet exit nozzle modifications, including an enhanced noise reduction configuration that minimizes the effect of the vanes on the background noise. Although the noise levels for this modified vane configuration were comparable to baseline tunnel background noise levels in this facility, installation of these modified vanes in an acoustic tunnel may be of concern because the noise levels for the vanes could be well above background noise levels in a quiet facility.

  17. Image Cytometric Analysis of Algal Spores for Evaluation of Antifouling Activities of Biocidal Agents.

    PubMed

    Il Koo, Bon; Lee, Yun-Soo; Seo, Mintae; Seok Choi, Hyung; Leng Seah, Geok; Nam, Taegu; Nam, Yoon Sung

    2017-07-31

    Chemical biocides have been widely used as marine antifouling agents, but their environmental toxicity impose regulatory restriction on their use. Although various surrogate antifouling biocides have been introduced, their comparative effectiveness has not been well investigated partly due to the difficulty of quantitative evaluation of their antifouling activity. Here we report an image cytometric method to quantitatively analyze the antifouling activities of seven commercial biocides using Ulva prolifera as a target organism, which is known to be a dominant marine species causing soft fouling. The number of spores settled on a substrate is determined through image analysis using the intrinsic fluorescence of chlorophylls in the spores. Pre-determined sets of size and shape of spores allow for the precise determination of the number of settled spores. The effects of biocide concentration and combination of different biocides on the spore settlement are examined. No significant morphological changes of Ulva spores are observed, but the amount of adhesive pad materials is appreciably decreased in the presence of biocides. It is revealed that the growth rate of Ulva is not directly correlated with the antifouling activities against the settlement of Ulva spores. This work suggests that image cytometric analysis is a very convenient, fast-processable method to directly analyze the antifouling effects of biocides and coating materials.

  18. Usefulness of bronchoalveolar lavage and flow cytometry in patients with hematological malignancies and respiratory failure.

    PubMed

    Ferrà, Christelle; Xicoy, Blanca; Castillo, Nerea; Morgades, Mireia; Juncà, Jordi; Andreo, Felipe; Millá, Fuensanta; Feliu, Evarist; Ribera, Josep-María

    2017-04-07

    Strategies to improve the efficiency of bronchoalveolar lavage (BAL) are needed. We conducted a study to establish the diagnostic value of BAL in patients with hematological malignancies and pulmonary infiltrates. The correlation of cytologic and flow cytometric study of BAL with the microbiological findings and the clinical evolution was determined. Seventy BAL were performed and flow cytometric study was analyzed in 23 of them. Fifty-three patients did not present any adverse event attributable to BAL. Anti-infectious therapy was modified in 64 (91%) patients. T lymphocyte count >0.3×10 9 /l in peripheral blood was associated with longer OS at 3 years (53 vs. 22%, p=.009). Higher CD4 (>20/μL) and CD8 (>35/μL) lymphocyte counts in the BAL were associated with a longer OS at 3 years: 82 vs. 21% (p=.030) and 80 vs. 23% (p=.059). Our study confirms the clinical value of BAL for treatment decision making in patients with hematological malignancies and acute respiratory failure. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  19. Implementation of a flow-dependent background error correlation length scale formulation in the NEMOVAR OSTIA system

    NASA Astrophysics Data System (ADS)

    Fiedler, Emma; Mao, Chongyuan; Good, Simon; Waters, Jennifer; Martin, Matthew

    2017-04-01

    OSTIA is the Met Office's Operational Sea Surface Temperature (SST) and Ice Analysis system, which produces L4 (globally complete, gridded) analyses on a daily basis. Work is currently being undertaken to replace the original OI (Optimal Interpolation) data assimilation scheme with NEMOVAR, a 3D-Var data assimilation method developed for use with the NEMO ocean model. A dual background error correlation length scale formulation is used for SST in OSTIA, as implemented in NEMOVAR. Short and long length scales are combined according to the ratio of the decomposition of the background error variances into short and long spatial correlations. The pre-defined background error variances vary spatially and seasonally, but not on shorter time-scales. If the derived length scales applied to the daily analysis are too long, SST features may be smoothed out. Therefore a flow-dependent component to determining the effective length scale has also been developed. The total horizontal gradient of the background SST field is used to identify regions where the length scale should be shortened. These methods together have led to an improvement in the resolution of SST features compared to the previous OI analysis system, without the introduction of spurious noise. This presentation will show validation results for feature resolution in OSTIA using the OI scheme, the dual length scale NEMOVAR scheme, and the flow-dependent implementation.

  20. EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal, reactive and malignant leukocytes

    PubMed Central

    van Dongen, J J M; Lhermitte, L; Böttcher, S; Almeida, J; van der Velden, V H J; Flores-Montero, J; Rawstron, A; Asnafi, V; Lécrevisse, Q; Lucio, P; Mejstrikova, E; Szczepański, T; Kalina, T; de Tute, R; Brüggemann, M; Sedek, L; Cullen, M; Langerak, A W; Mendonça, A; Macintyre, E; Martin-Ayuso, M; Hrusak, O; Vidriales, M B; Orfao, A

    2012-01-01

    Most consensus leukemia & lymphoma antibody panels consist of lists of markers based on expert opinions, but they have not been validated. Here we present the validated EuroFlow 8-color antibody panels for immunophenotyping of hematological malignancies. The single-tube screening panels and multi-tube classification panels fit into the EuroFlow diagnostic algorithm with entries defined by clinical and laboratory parameters. The panels were constructed in 2–7 sequential design–evaluation–redesign rounds, using novel Infinicyt software tools for multivariate data analysis. Two groups of markers are combined in each 8-color tube: (i) backbone markers to identify distinct cell populations in a sample, and (ii) markers for characterization of specific cell populations. In multi-tube panels, the backbone markers were optimally placed at the same fluorochrome position in every tube, to provide identical multidimensional localization of the target cell population(s). The characterization markers were positioned according to the diagnostic utility of the combined markers. Each proposed antibody combination was tested against reference databases of normal and malignant cells from healthy subjects and WHO-based disease entities, respectively. The EuroFlow studies resulted in validated and flexible 8-color antibody panels for multidimensional identification and characterization of normal and aberrant cells, optimally suited for immunophenotypic screening and classification of hematological malignancies. PMID:22552007

  1. A retrospective review of acute myeloid leukaemia in 35 dogs diagnosed by a combination of morphologic findings, flow cytometric immunophenotyping and cytochemical staining results (2007-2015).

    PubMed

    Davis, L L; Hume, K R; Stokol, T

    2018-06-01

    Acute myeloid leukaemia (AML) is an uncommon, rapidly progressive neoplasm in dogs. The aim of this retrospective study was to characterize the clinical presentation, haematologic findings, diagnostic imaging results, treatment and survival time of a contemporary cohort of dogs with AML. Diagnosis was based on >20% blasts in bone marrow or blood identified as myeloid based on morphologic findings, flow cytometric immunophenotyping and cytochemical staining. Medical records of 35 dogs diagnosed with AML from 2007 to 2015 were included. Most dogs presented with inappetence (66%) and lethargy (57%) and physical examination findings of peripheral lymphadenopathy (74%) and tachypnea (62%). Common haematologic findings were quantifiable circulating blasts (85%; median blast count 35 700/μL; range: 300-276 500/μL), anaemia (median haematocrit 34%; range: 11%-52%) and thrombocytopenia (median 57 000/μL; range: 9000-252 000/μL). Bicytopenia and pancytopenia were each found in 44% of dogs. Follow-up information was available for 34 dogs. The overall median survival time from diagnosis was 19 days (range: 1-121 days). Clinical progression in some dogs was not as rapid as previously reported. Haematologic responses to various chemotherapeutics were documented in 3 dogs, with associated survival times of 62, 103 and 121 days. Dogs treated with prednisone or a combination of chemotherapy and prednisone had improved survival compared to dogs that received symptomatic care only (P < .0001). Our results show canine AML has an overlapping clinical presentation with lymphoma. The prognosis for canine AML remains extremely guarded. Further studies are needed to optimize therapeutic regimens for dogs with AML. © 2017 John Wiley & Sons Ltd.

  2. Simultaneous flow cytometric measurement of antigen attachment to phagocytes and phagocytosis.

    PubMed

    Laopajon, Witida; Takheaw, Nuchjira; Kasinrerk, Watchara; Pata, Supansa

    2016-01-01

    The current available assays cannot differentiate the stages of phagocytosis. We, therefore, established methods for concurrent detection of antigen attachment and engulfment by phagocyte using latex beads coated with lipopolysaccharide, rabbit IgG, and carboxyfluorescein diacetate succinimidyl ester. The generated beads were incubated with whole blood at 37°C for 1 hr and stained with PE-Cy5.5 anti-rabbit IgG antibody. By flow cytometry, attachment and phagocytic processes could be detected, simultaneously. The established method is a valuable tool for diagnosis of phagocytic disorder and study of molecules involved in phagocytosis.

  3. Validation of a HLA-A2 tetramer flow cytometric method, IFNgamma real time RT-PCR, and IFNgamma ELISPOT for detection of immunologic response to gp100 and MelanA/MART-1 in melanoma patients

    PubMed Central

    Xu, Yuanxin; Theobald, Valerie; Sung, Crystal; DePalma, Kathleen; Atwater, Laura; Seiger, Keirsten; Perricone, Michael A; Richards, Susan M

    2008-01-01

    Background HLA-A2 tetramer flow cytometry, IFNγ real time RT-PCR and IFNγ ELISPOT assays are commonly used as surrogate immunological endpoints for cancer immunotherapy. While these are often used as research assays to assess patient's immunologic response, assay validation is necessary to ensure reliable and reproducible results and enable more accurate data interpretation. Here we describe a rigorous validation approach for each of these assays prior to their use for clinical sample analysis. Methods Standard operating procedures for each assay were established. HLA-A2 (A*0201) tetramer assay specific for gp100209(210M) and MART-126–35(27L), IFNγ real time RT-PCR and ELISPOT methods were validated using tumor infiltrating lymphocyte cell lines (TIL) isolated from HLA-A2 melanoma patients. TIL cells, specific for gp100 (TIL 1520) or MART-1 (TIL 1143 and TIL1235), were used alone or spiked into cryopreserved HLA-A2 PBMC from healthy subjects. TIL/PBMC were stimulated with peptides (gp100209, gp100pool, MART-127–35, or influenza-M1 and negative control peptide HIV) to further assess assay performance characteristics for real time RT-PCR and ELISPOT methods. Validation parameters included specificity, accuracy, precision, linearity of dilution, limit of detection (LOD) and limit of quantification (LOQ). In addition, distribution was established in normal HLA-A2 PBMC samples. Reference ranges for assay controls were established. Results The validation process demonstrated that the HLA-A2 tetramer, IFNγ real time RT-PCR, and IFNγ ELISPOT were highly specific for each antigen, with minimal cross-reactivity between gp100 and MelanA/MART-1. The assays were sensitive; detection could be achieved at as few as 1/4545–1/6667 cells by tetramer analysis, 1/50,000 cells by real time RT-PCR, and 1/10,000–1/20,000 by ELISPOT. The assays met criteria for precision with %CV < 20% (except ELISPOT using high PBMC numbers with %CV < 25%) although flow cytometric assays and

  4. A flow cytometric method for assessing viability of intraerythrocytic hemoparasites.

    PubMed

    Wyatt, C R; Goff, W; Davis, W C

    1991-06-24

    We have developed a rapid, reliable method of evaluating growth and viability of intraerythrocytic protozoan hemoparasites. The assay involves the selective uptake and metabolic conversion of hydroethidine to ethidium by live parasites present in intact erythrocytes. The red fluorescence imparted by ethidium intercalated into the DNA of the parasite permits the use of flow cytometry to distinguish infected erythrocytes with viable parasites from uninfected erythrocytes and erythrocytes containing dead parasites. Comparison of the fluorochromasia technique of enumerating the number and viability of hemoparasites in cultured erythrocytes with enumeration in Giemsa-stained films and uptake of [3H]hypoxanthine demonstrated the fluorochromasia technique yields comparable results. Studies with the hemoparasite, Babesia bovis, have shown the fluorochromasia technique can also be used to monitor the effect of parasiticidal drugs on parasites in vitro. The cumulative studies with the fluorochromasia assay suggest the assay will also prove useful in investigations focused on analysis of the immune response to hemoparasites and growth in vitro.

  5. Effects of background stimulation upon eye-movement information.

    PubMed

    Nakamura, S

    1996-04-01

    To investigate the effects of background stimulation upon eye-movement information (EMI), the perceived deceleration of the target motion during pursuit eye movement (Aubert-Fleishl paradox) was analyzed. In the experiment, a striped pattern was used as a background stimulus with various brightness contrasts and spatial frequencies for serially manipulating the attributions of the background stimulus. Analysis showed that the retinal-image motion of the background stimulus (optic flow) affected eye-movement information and that the effects of optic flow became stronger when high contrast and low spatial frequency stripes were presented as the background stimulus. In conclusion, optic flow is one source of eye-movement information in determining real object motion, and the effectiveness of optic flow depends on the attributes of the background stimulus.

  6. Effect of freezing of sputum samples on flow cytometric analysis of lymphocyte subsets.

    PubMed

    Jaksztat, E; Holz, O; Paasch, K; Kelly, M M; Hargreave, F E; Cox, G; Magnussen, H; Jörres, R A

    2004-08-01

    Sputum samples should be processed shortly after induction to prevent cell degradation. For intermediate storage, freezing of homogenised samples or immediate fixation have been shown to be suitable for cytospins. The aim of this study was to investigate whether freezing or immediate fixation of sputum affect the analysis of lymphocyte subsets by flow cytometry. Selected plugs from 24 sputum samples were homogenised. One aliquot was processed immediately and analysed by flow cytometry. A second aliquot was homogenised, frozen at -20 C after addition of dimethylsulfoxide and stored for a median time of 6 days. In six samples a third aliquot was fixed in formalin after induction and stored for up to 72 h before further processing. Compared to immediate processing, percentages of total lymphocytes and T-suppressor cells were elevated after being frozen, with a minor decrease in the T4/T8 ratio. Proportions of total lymphocytes, T-helper and T-suppressor cells correlated between native and frozen samples, intra-class correlation coefficients being 0.74, 0.85 and 0.70, respectively. The formalin-fixed aliquots could not be analysed with the antibodies used. In conclusion, freezing seems to be a suitable technique to store sputum samples for flow cytometry of CD3, CD4 and CD8 lymphocyte subsets. Its effects were minor compared to the variation between subjects.

  7. Genome size variation in the pine fusiform rust pathogen Cronartium quercuum f.sp. fusiforme as determined by flow cytometry

    Treesearch

    Claire L Anderson; Thomas L Kubisiak; C Dana Nelson; Jason A Smith; John M Davis

    2010-01-01

    The genome size of the pine fusiform rust pathogen Cronartium quercuum f.sp. fusiforme (Cqf) was determined by flow cytometric analysis of propidium iodide-stained, intact haploid pycniospores with haploid spores of two genetically well characterized fungal species, Sclerotinia sclerotiorum and Puccinia graminis f.sp. tritici, as size standards. The Cqf haploid genome...

  8. Flow cytometric assay to assess short-term effects of personal care products on the marine microalga Tetraselmis suecica.

    PubMed

    Seoane, Marta; Esperanza, Marta; Rioboo, Carmen; Herrero, Concepción; Cid, Ángeles

    2017-03-01

    Large quantities of personal care products (PCPs) are used daily and many of their chemical ingredients are subsequently released into marine environments. Cultures of the marine microalga Tetraselmis suecica were exposed for 24 h to three emerging compounds included in the main classes of PCPs: the UV filter benzophenone-3 (BP-3), the disinfectant triclosan (TCS) and the fragrance tonalide (AHTN). Concentrations tested, expressed as cellular quota (pg cell -1 ), ranged from 5 to 40 for BP-3, from 2 to 16 for TCS and from 1.2 to 2.4 for AHTN. A small cytometric panel was carried out to evaluate key cytotoxicity biomarkers including inherent cell properties, growth and metabolic activity and cytoplasmic membrane properties. BP-3 caused a significant increase in growth rate, metabolic activity and chlorophyll a fluorescence from 10 pg cell -1 . However, growth and esterase activity decreased in cells exposed to all TCS and AHTN concentrations, except the lowest ones. Also these two compounds provoked a significant swelling of cells, more pronounced in the case of TCS-exposed cells. Although all treated cells remained viable, changes in membrane potential were observed. BP-3 and AHTN caused a significant depolarization of cells from 10 to 1.6 pg cell -1 , respectively; however all TCS concentrations assayed caused a noticeable hyperpolarization of cells. Metabolic activity and cytoplasmic membrane potential were the most sensitive parameters. It can be concluded that the toxicological model used and the toxicological parameters evaluated are suitable to assess the toxicity of these emerging contaminants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Flow Cytometric Human Leukocyte Antigen-B27 Typing with Stored Samples for Batch Testing

    PubMed Central

    Seo, Bo Young

    2013-01-01

    Background Flow cytometry (FC) HLA-B27 typing is still used extensively for the diagnosis of spondyloarthropathies. If patient blood samples are stored for a prolonged duration, this testing can be performed in a batch manner, and in-house cellular controls could easily be procured. In this study, we investigated various methods of storing patient blood samples. Methods We compared four storage methods: three methods of analyzing lymphocytes (whole blood stored at room temperature, frozen mononuclear cells, and frozen white blood cells [WBCs] after lysing red blood cells [RBCs]), and one method using frozen platelets (FPLT). We used three ratios associated with mean fluorescence intensities (MFI) for HLAB27 assignment: the B27 MFI ratio (sample/control) for HLA-B27 fluorescein-5-isothiocyanate (FITC); the B7 MFI ratio for HLA-B7 phycoerythrin (PE); and the ratio of these two ratios, B7/B27 ratio. Results Comparing the B27 MFI ratios of each storage method for the HLA-B27+ samples and the B7/B27 ratios for the HLA-B7+ samples revealed that FPLT was the best of the four methods. FPLT had a sensitivity of 100% and a specificity of 99.3% for HLA-B27 assignment in DNA-typed samples (N=164) when the two criteria, namely, B27 MFI ratio >4.0 and B7/B27 ratio <1.5, were used. Conclusions The FPLT method was found to offer a simple, economical, and accurate method of FC HLA-B27 typing by using stored patient samples. If stored samples are used, this method has the potential to replace the standard FC typing method when used in combination with a complementary DNA-based method. PMID:23667843

  10. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    PubMed Central

    2012-01-01

    Background Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample

  11. First measurement of the bulk flow of nearby galaxies using the cosmic microwave background

    NASA Astrophysics Data System (ADS)

    Lavaux, Guilhem; Afshordi, Niayesh; Hudson, Michael J.

    2013-04-01

    Peculiar velocities in the nearby Universe can be measured via the kinetic Sunyaev-Zel'dovich (kSZ) effect. Using a statistical method based on an optimized cross-correlation with nearby galaxies, we extract the kSZ signal generated by plasma halo of galaxies from the cosmic microwave background (CMB) temperature anisotropies observed by the Wilkinson Microwave Anisotropy Probe (WMAP). Marginalizing over the thermal Sunyaev-Zel'dovich contribution from clusters of galaxies, possible unresolved point source contamination, and Galactic foregrounds, we find a kSZ bulk flow signal present at the ˜90 per cent confidence level in the seven-year WMAP data. When only galaxies within 50 h-1 Mpc are included in the kSZ template, we find a bulk flow in the CMB frame of |V| = 533 ± 263 km s-1, in the direction l = 324 ± 27, b = -7 ± 17, consistent with bulk flow measurements on a similar scale using classical distance indicators. We show how this comparison constrains, for the first time, the (ionized) baryonic budget in the local universe. On very large (˜500 h-1 Mpc) scales, we find a 95 per cent upper limit of 470 km s-1, inconsistent with some analyses of bulk flow of clusters from the kSZ. We estimate that the significance of the bulk flow signal may increase to 3σ-5σ using data from the Planck probe.

  12. Characteristics of transonic spherical symmetric accretion flow in Schwarzschild-de Sitter and Schwarzschild anti-de Sitter backgrounds, in pseudo-general relativistic paradigm

    NASA Astrophysics Data System (ADS)

    Ghosh, Shubhrangshu; Banik, Prabir

    2015-07-01

    In this paper, we present a complete work on steady state spherically symmetric Bondi type accretion flow in the presence of cosmological constant (Λ) in both Schwarzschild-de Sitter (SDS) and Schwarzschild anti-de Sitter (SADS) backgrounds considering an isolated supermassive black hole (SMBH), with the inclusion of a simple radiative transfer scheme, in the pseudo-general relativistic paradigm. We do an extensive analysis on the transonic behavior of the Bondi type accretion flow onto the cosmological BHs including a complete analysis of the global parameter space and the stability of flow, and do a complete study of the global family of solutions for a generic polytropic flow. Bondi type accretion flow in SADS background renders multiplicity in its transonic behavior with inner "saddle" type and outer "center" type sonic points, with the transonic solutions forming closed loops or contours. There is always a limiting value for ∣Λ∣ up to which we obtain valid stationary transonic solutions, which correspond to both SDS and SADS geometries; this limiting value moderately increases with the increasing radiative efficiency of the flow, especially correspond to Bondi type accretion flow in SADS background. Repulsive Λ suppresses the Bondi accretion rate by an order of magnitude for relativistic Bondi type accretion flow for a certain range in temperature, and with a marginal increase in the Bondi accretion rate if the corresponding accretion flow occurs in SADS background. However, for a strongly radiative Bondi type accretion flow with high mass accretion rate, the presence of cosmological constant do not much influence the corresponding Bondi accretion rate of the flow. Our analysis show that the relic cosmological constant has a substantial effect on Bondi type accretion flow onto isolated SMBHs and their transonic solutions beyond length-scale of kiloparsecs, especially if the Bondi type accretion occurs onto the host supergiant ellipticals or central

  13. What Is Fanconi Anemia?

    MedlinePlus

    ... people who don't have FA. Cytometric Flow Analysis Cytometric flow analysis, or CFA, is done in a lab. This ... lungs, is connected to the esophagus, which carries food to the stomach. This can cause serious breathing, ...

  14. Detection of early changes in lung cell cytology by flow-systems analysis techniques. [Rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinkamp, J.A.; Wilson, J.S.; Svitra, Z.V.

    1980-03-01

    Ongoing experiments designed to develop automated flow-analysis methods for assaying damage to pulmonary lavage cells in experimental animals exposed by inhalation to environmental pollutants are summarized. Pulmonary macrophages were characterized on their ability to phagocytize polystyrene latex fluorescent spheres. Lung cells consisting primarily of macrophages and leukocytes were analyzed for fluorescence (phagocytosis of spheres) and size using flow cytometric methods. Studies also concentrated on combining phagocytosis with other cellular parameters (DNA content, cell viability, and B-glucuronidase activity). As baseline studies are completed in normal animals, experimental animals will be exposed to gaseous and particulate environmental pollutants. (ERB

  15. Mean and turbulent flow downstream of a low-intensity fire: influence of canopy and background atmospheric conditions

    Treesearch

    Michael T. Kiefer; Warren E. Heilman; Shiyuan Zhong; Joseph J. Charney; Xindi Bian

    2015-01-01

    This study examines the sensitivity of mean and turbulent flow in the planetary boundary layer and roughness sublayer to a low-intensity fire and evaluates whether the sensitivity is dependent on canopy and background atmospheric properties. The ARPS-CANOPY model, a modified version of the Advanced Regional Prediction System (ARPS) model with a canopy parameterization...

  16. Minimal disease detection of B-cell lymphoproliferative disorders by flow cytometry: multidimensional cluster analysis.

    PubMed

    Duque, Ricardo E

    2012-04-01

    Flow cytometric analysis of cell suspensions involves the sequential 'registration' of intrinsic and extrinsic parameters of thousands of cells in list mode files. Thus, it is almost irresistible to describe phenomena in numerical terms or by 'ratios' that have the appearance of 'accuracy' due to the presence of numbers obtained from thousands of cells. The concepts involved in the detection and characterization of B cell lymphoproliferative processes are revisited in this paper by identifying parameters that, when analyzed appropriately, are both necessary and sufficient. The neoplastic process (cluster) can be visualized easily because the parameters that distinguish it form a cluster in multidimensional space that is unique and distinguishable from neighboring clusters that are not of diagnostic interest but serve to provide a background. For B cell neoplasia it is operationally necessary to identify the multidimensional space occupied by a cluster whose kappa:lambda ratio is 100:0 or 0:100. Thus, the concept of kappa:lambda ratio is without meaning and would not detect B cell neoplasia in an unacceptably high number of cases.

  17. Visualization of Flow Separation Around an Atmospheric Entry Capsule at Low-Subsonic Mach Number Using Background-Oriented Schlieren (BOS)

    NASA Technical Reports Server (NTRS)

    Mizukaki, Toshiharu; Borg, Stephen E.; Danehy, Paul M.; Murman, Scott M.

    2014-01-01

    This paper presents the results of visualization of separated flow around a generic entry capsule that resembles the Apollo Command Module (CM) and the Orion Multi-Purpose Crew Vehicle (MPCV). The model was tested at flow speeds up to Mach 0.4 at a single angle of attack of 28 degrees. For manned spacecraft using capsule-shaped vehicles, certain flight operations such as emergency abort maneuvers soon after launch and flight just prior to parachute deployment during the final stages of entry, the command module may fly at low Mach number. Under these flow conditions, the separated flow generated from the heat-shield surface on both windward and leeward sides of the capsule dominates the wake flow downstream of the capsule. In this paper, flow visualization of the separated flow was conducted using the background-oriented schlieren (BOS) method, which has the capability of visualizing significantly separated wake flows without the particle seeding required by other techniques. Experimental results herein show that BOS has detection capability of density changes on the order of 10(sup-5).

  18. A novel fluorescent sensor for measurement of CFTR function by flow cytometry.

    PubMed

    Vijftigschild, Lodewijk A W; van der Ent, Cornelis K; Beekman, Jeffrey M

    2013-06-01

    Mutations in the cystic fibrosis transmembrane conductance regulator (CFTR) gene cause cystic fibrosis. CFTR-dependent iodide transport measured by fluorescent quenching of ectopically expressed halide-sensitive yellow fluorescent protein (YFP) is widely being used to study CFTR function by microscopy or plate readers. Since YFP fluorescence in these systems is dependent on YFP expression levels and iodide concentration, differences in sensor expression level between experimental units are normalized at the start of each experiment. To allow accurate measurement of CFTR function by flow cytometry, we reasoned that co-expression of an iodide insensitive fluorescent protein would allow for normalization of sensor expression levels and more accurate quantification of CFTR function. Our data indicated that dsRed and mKate fluorescence are iodide insensitive, and we determined an optimal format for co-expression of these fluorescent proteins with halide-sensitive YFP. We showed using microscopy that ratiometric measurement (YFP/mKate) corrects for differences in sensor expression levels. Ratiometric measurements were essential to accurately measure CFTR function by flow cytometry that we here describe for the first time. Mixing of wild type or mutant CFTR expressing cells indicated that addition of approximately 10% of wild type CFTR expressing cells could be distinguished by ratiometric YFP quenching. Flow cytometric ratiometric YFP quenching also allowed us to study CFTR mutants associated with differential residual function upon ectopic expression. Compared with conventional plate-bound CFTR function assays, the flow cytometric approach described here can be used to study CFTR function in suspension cells. It may be further adapted to study CFTR function in heterologous cell populations using cell surface markers and selection of cells that display high CFTR function by cell sorting. Copyright © 2013 International Society for Advancement of Cytometry.

  19. Flow cytometric monitoring of hormone receptor expression in human solid tumors

    NASA Astrophysics Data System (ADS)

    Krishan, Awtar

    2002-05-01

    Hormone receptor expression in human breast and prostate tumors is of diagnostic and therapeutic importance. With the availability of anti-estrogen, androgen and progesterone antibodies, immunohistochemistry has become a standard tool for determination of receptor expression in human tumor biopsies. However, this method is dependent on examination of a small number of cells under a microscope and the data obtained in most cases is not quantitative. As most of the commercially used anti-hormone antibodies have nuclear specificity, we have developed methods for isolation and antigen unmasking of nuclei from formalin fixed/paraffin embedded archival human tumors. After immunostaining with the antibodies and propidium iodide (for DNA content and cell cycle analysis), nuclei are analyzed by multiparametric laser flow cytometry for hormone receptor expression, DNA content, aneuploidy and cell cycle determination. These multiparametric methods are especially important for retrospective studies seeking to correlate hormone receptor expression with clinical response to anti-hormonal therapy of human breast and prostate tumors.

  20. Flow Cytometry with Gold Nanoparticles and their Clusters as scattering Contrast Agents: FDTD Simulation of Light-Cell Interaction

    PubMed Central

    Tanev, Stoyan; Sun, Wenbo; Pond, James; Tuchin, Valery V.; Zharov, Vladimir P.

    2010-01-01

    The formulation of the Finite-Difference Time-Domain (FDTD) approach is presented in the framework of its potential applications to in vivo flow cytometry based on light scattering. The consideration is focused on comparison of light scattering by a single biological cell alone in controlled refractive index matching conditions and by cells labeled by gold nanoparticles. The optical schematics including phase contrast (OPCM) microscopy as a prospective modality for in vivo flow cytometry is also analyzed. The validation of the FDTD approach for the simulation of flow cytometry may open a new avenue in the development of advanced cytometric techniques based on scattering effects from nanoscale targets. PMID:19670359

  1. DNA flow cytometric analysis of primary operable breast cancer. Relation of ploidy and S-phase fraction to outcome of patients in NSABP B-04.

    PubMed

    Fisher, B; Gunduz, N; Costantino, J; Fisher, E R; Redmond, C; Mamounas, E P; Siderits, R

    1991-10-01

    Between 1971 and 1974, 1665 women with primary operable breast cancer were randomized into a National Surgical Adjuvant Breast and Bowel Project (NSABP) trial (B-04) conducted to evaluate the effectiveness of several different regimens of surgical and radiation therapy. No systemic therapy was given. Cells from archival paraffin-embedded tumor tissue taken from 398 patients were analyzed for ploidy and S-phase fraction (SPF) using flow cytometry. Characteristics and outcome of patients with satisfactory DNA histograms were comparable to those from whom no satisfactory cytometric studies were available. In patients with diploid tumors (43%), the mean SPF was 3.4% +/- 2.3%; in the aneuploid population (57%), the SPF was 7.9% +/- 6.3%. Only 29.9% +/- 17.3% of cells in aneuploid tumors were aneuploid. Diploid tumors were more likely than aneuploid tumors to be of good nuclear grade (P less than 0.001) and smaller size (P equals 0.03). More tumors with high SPF were of poor nuclear grade than were tumors with low SPF (P equals 0.002). No significant difference in 10-year disease-free survival (P equals 0.3) or survival (P equals 0.1) was found between women with diploid or aneuploid tumors. Patients with low SPF tumors had a 13% better disease-free survival (P equals 0.0006) than those with a high SPF and a 14% better survival (P equals 0.007) at 10 years than patients with high SPF tumors. After adjustment for clinical tumor size, the difference in both disease-free survival and survival between patients with high and low SPF tumors was only 10% (P equals 0.04 and 0.08, respectively). Although SPF was found to be of independent prognostic significance for disease-free survival and marginal significance for survival, it did not detect patients with such a good prognosis as to preclude their receiving chemotherapy. The overall survival of patients with low SPF was only 53% at 10 years. These findings and those of others indicate that additional studies are necessary

  2. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    PubMed

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in

  3. Whole blood flow cytometric analysis of Ureaplasma-stimulated monocytes from pregnant women.

    PubMed

    Friedland, Yael D; Lee-Pullen, Tracey F; Nathan, Elizabeth; Watts, Rory; Keelan, Jeffrey A; Payne, Matthew S; Ireland, Demelza J

    2015-06-01

    We hypothesised that circulating monocytes of women with vaginal colonisation with Ureaplasma spp., genital microorganisms known to cause inflammation-driven preterm birth, would elicit a tolerised cytokine response to subsequent in vitro Ureaplasma parvum serovar 3 (UpSV3) stimulation. Using multi-parameter flow cytometry, we found no differences with regard to maternal colonisation status in the frequency of TNF-α-, IL-6-, IL-8- and IL-1β-expressing monocytes in response to subsequent UpSV3 stimulation (P > 0.10 for all cytokines). We conclude that vaginal Ureaplasma spp. colonisation does not specifically tolerise monocytes of pregnant women towards decreased responses to subsequent stimulation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Flow Cytometric Methods for Circulating Tumor Cell Isolation and Molecular Analysis.

    PubMed

    Bhagwat, Neha; Carpenter, Erica L

    2017-01-01

    Circulating tumor cells provide a non-invasive source of tumor material that can be valuable at all stages of disease management, including screening and early diagnosis, monitoring response to therapy, identifying therapeutic targets, and assessing development of drug resistance. Cells isolated from the blood of cancer patients can be used for phenotypic analysis, tumor genotyping, transcriptional profiling, as well as for ex vivo culture of isolated cells. There are a variety of novel technologies currently being developed for the detection and analysis of rare cells in circulation of cancer patients. Flow cytometry is a powerful cell analysis platform that is increasingly being used in this field of study due to its relatively high throughput and versatility with respect to the large number of commercially available antibodies and fluorescent probes available to translational and clinical researchers. More importantly, it offers the ability to easily recover viable cells with high purity that are suitable for downstream molecular analysis, thus making it an attractive technology for cancer research and as a diagnostic tool.

  5. Digital Analysis and Sorting of Fluorescence Lifetime by Flow Cytometry

    PubMed Central

    Houston, Jessica P.; Naivar, Mark A.; Freyer, James P.

    2010-01-01

    Frequency-domain flow cytometry techniques are combined with modifications to the digital signal processing capabilities of the Open Reconfigurable Cytometric Acquisition System (ORCAS) to analyze fluorescence decay lifetimes and control sorting. Real-time fluorescence lifetime analysis is accomplished by rapidly digitizing correlated, radiofrequency modulated detector signals, implementing Fourier analysis programming with ORCAS’ digital signal processor (DSP) and converting the processed data into standard cytometric list mode data. To systematically test the capabilities of the ORCAS 50 MS/sec analog-to-digital converter (ADC) and our DSP programming, an error analysis was performed using simulated light scatter and fluorescence waveforms (0.5–25 ns simulated lifetime), pulse widths ranging from 2 to 15 µs, and modulation frequencies from 2.5 to 16.667 MHz. The standard deviations of digitally acquired lifetime values ranged from 0.112 to >2 ns, corresponding to errors in actual phase shifts from 0.0142° to 1.6°. The lowest coefficients of variation (<1%) were found for 10-MHz modulated waveforms having pulse widths of 6 µs and simulated lifetimes of 4 ns. Direct comparison of the digital analysis system to a previous analog phase-sensitive flow cytometer demonstrated similar precision and accuracy on measurements of a range of fluorescent microspheres, unstained cells and cells stained with three common fluorophores. Sorting based on fluorescence lifetime was accomplished by adding analog outputs to ORCAS and interfacing with a commercial cell sorter with a radiofrequency modulated solid-state laser. Two populations of fluorescent microspheres with overlapping fluorescence intensities but different lifetimes (2 and 7 ns) were separated to ~98% purity. Overall, the digital signal acquisition and processing methods we introduce present a simple yet robust approach to phase-sensitive measurements in flow cytometry. The ability to simply and inexpensively

  6. Two New Nuclear Isolation Buffers for Plant DNA Flow Cytometry: A Test with 37 Species

    PubMed Central

    Loureiro, João; Rodriguez, Eleazar; Doležel, Jaroslav; Santos, Conceição

    2007-01-01

    Background and Aims After the initial boom in the application of flow cytometry in plant sciences in the late 1980s and early 1990s, which was accompanied by development of many nuclear isolation buffers, only a few efforts were made to develop new buffer formulas. In this work, recent data on the performance of nuclear isolation buffers are utilized in order to develop new buffers, general purpose buffer (GPB) and woody plant buffer (WPB), for plant DNA flow cytometry. Methods GPB and WPB were used to prepare samples for flow cytometric analysis of nuclear DNA content in a set of 37 plant species that included herbaceous and woody taxa with leaf tissues differing in structure and chemical composition. The following parameters of isolated nuclei were assessed: forward and side light scatter, propidium iodide fluorescence, coefficient of variation of DNA peaks, quantity of debris background, and the number of particles released from sample tissue. The nuclear genome size of 30 selected species was also estimated using the buffer that performed better for a given species. Key Results In unproblematic species, the use of both buffers resulted in high quality samples. The analysis of samples obtained with GPB usually resulted in histograms of DNA content with higher or similar resolution than those prepared with the WPB. In more recalcitrant tissues, such as those from woody plants, WPB performed better and GPB failed to provide acceptable results in some cases. Improved resolution of DNA content histograms in comparison with previously published buffers was achieved in most of the species analysed. Conclusions WPB is a reliable buffer which is also suitable for the analysis of problematic tissues/species. Although GPB failed with some plant species, it provided high-quality DNA histograms in species from which nuclear suspensions are easy to prepare. The results indicate that even with a broad range of species, either GPB or WPB is suitable for preparation of high

  7. Flow Visualization of Aircraft in Flight by Means of Background Oriented Schlieren Using Celestial Objects

    NASA Technical Reports Server (NTRS)

    Hill, Michael A.; Haering, Edward A., Jr.

    2017-01-01

    The Background Oriented Schlieren using Celestial Objects series of flights was undertaken in the spring of 2016 at National Aeronautics and Space Administration Armstrong Flight Research Center to further develop and improve a flow visualization technique which can be performed from the ground upon flying aircraft. Improved hardware and imaging techniques from previous schlieren tests were investigated. A United States Air Force T-38C and NASA B200 King Air aircraft were imaged eclipsing the sun at ranges varying from 2 to 6 nautical miles, at subsonic and supersonic speeds.

  8. Scalable clustering algorithms for continuous environmental flow cytometry.

    PubMed

    Hyrkas, Jeremy; Clayton, Sophie; Ribalet, Francois; Halperin, Daniel; Armbrust, E Virginia; Howe, Bill

    2016-02-01

    Recent technological innovations in flow cytometry now allow oceanographers to collect high-frequency flow cytometry data from particles in aquatic environments on a scale far surpassing conventional flow cytometers. The SeaFlow cytometer continuously profiles microbial phytoplankton populations across thousands of kilometers of the surface ocean. The data streams produced by instruments such as SeaFlow challenge the traditional sample-by-sample approach in cytometric analysis and highlight the need for scalable clustering algorithms to extract population information from these large-scale, high-frequency flow cytometers. We explore how available algorithms commonly used for medical applications perform at classification of such a large-scale, environmental flow cytometry data. We apply large-scale Gaussian mixture models to massive datasets using Hadoop. This approach outperforms current state-of-the-art cytometry classification algorithms in accuracy and can be coupled with manual or automatic partitioning of data into homogeneous sections for further classification gains. We propose the Gaussian mixture model with partitioning approach for classification of large-scale, high-frequency flow cytometry data. Source code available for download at https://github.com/jhyrkas/seaflow_cluster, implemented in Java for use with Hadoop. hyrkas@cs.washington.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Flow cytometry with gold nanoparticles and their clusters as scattering contrast agents: FDTD simulation of light-cell interaction.

    PubMed

    Tanev, Stoyan; Sun, Wenbo; Pond, James; Tuchin, Valery V; Zharov, Vladimir P

    2009-09-01

    The formulation of the finite-difference time-domain (FDTD) approach is presented in the framework of its potential applications to in-vivo flow cytometry based on light scattering. The consideration is focused on comparison of light scattering by a single biological cell alone in controlled refractive-index matching conditions and by cells labeled by gold nanoparticles. The optical schematics including phase contrast (OPCM) microscopy as a prospective modality for in-vivo flow cytometry is also analyzed. The validation of the FDTD approach for the simulation of flow cytometry may open up a new avenue in the development of advanced cytometric techniques based on scattering effects from nanoscale targets. 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

  10. Flow cytometric characterization of the response of Fanconi's anemia cells to mitomycin C treatment.

    PubMed

    Kaiser, T N; Lojewski, A; Dougherty, C; Juergens, L; Sahar, E; Latt, S A

    1982-03-01

    DNA flow histogram analysis, using 33342 Hoechst as a stain, has been used to detect the effect of the potentially bifunctional alkylating agent, mitomycin C (MMC) on dermal fibroblasts from patients with Fanconi's anemia (FA), a hereditary human disease characterized by pancytopenia, hypersensitivity to DNA-crosslinking agents, congenital abnormalities and a predisposition for neoplasia. At 24 or 48 hr after a 2-hr exposure to 0.05 or 0.10 micrograms/ml MMC, (3)HdT incorporation was reduced to a greater extent in FA cells than in normal cells. Cells sorted from the last half of S phase showed a slightly greater inhibition of (3)HdT incorporation than did those sorted from the first half of S. Fanconi's anemia cells exhibited a marked accumulation in the G(2) + M peak of flow histograms following exposure to MMC. Twenty-four hr after treatment with .0.5 micrograms/ml MMC, the G(2) + M fraction of FA cells (eight lines) increased to more than 0.5 from a control value of approximately 0.02. Both normals (six lines) and heterozygotes (eight lines) showed, on the average, much less of a G(2) + M increment than did FA cells, even after exposure to 0.1 micrograms/ml MMC. Examination of cells sorted from the G(2) + M peak revealed that MMC-treated FA cells were blocked prior to mitosis. To determine whether the response of FA cells was specific for bifunctional alkylating agent, cells were also treated with ethylmethanesulfonate, a monofunctional agent. Twenty-four hours after exposure to 0.25 or 0.5 mg/ml ethylmethanesulfonate, FA and normal cells showed similar, small increases in the G(2) + M peak. The results suggest the utility of flow cytometry in the diagnostic evaluation of fibroblasts from patients suspected of having Fanconi's anemia.

  11. Flow cytometry shows added value in diagnosing lymphoma in brain biopsies.

    PubMed

    van der Meulen, Matthijs; Bromberg, Jacoline E C; Lam, King H; Dammers, Ruben; Langerak, Anton W; Doorduijn, Jeanette K; Kros, Johan M; van den Bent, Martin J; van der Velden, Vincent H J

    2018-05-10

    To assess the sensitivity, specificity and turnaround time of flow cytometric analysis on brain biopsies compared to histology plus immunohistochemistry analysis in tumors with clinical suspicion of lymphoma. All brain biopsies performed between 2010 and 2015 at our institution and analyzed by both immunohistochemistry and flow cytometry were included in this retrospective study. Immunohistochemistry was considered the gold standard. In a total of 77 biopsies from 71 patients, 49 lymphomas were diagnosed by immunohistochemistry, flow cytometry results were concordant in 71 biopsies (92,2%). We found a specificity and sensitivity of flow cytometry of 100% and 87,8%, respectively. The time between the biopsy and reporting the result (turnaround time) was significantly shorter for flow cytometry, compared to immunohistochemistry (median: 1 versus 5 days). Flow cytometry has a high specificity and can confirm the diagnosis of a lymphoma significantly faster than immunohistochemistry. This allows for rapid initiation of treatment in this highly aggressive tumor. However, since its sensitivity is less than 100%, we recommend to perform histology plus immunohistochemistry in parallel to flow cytometry. This article is protected by copyright. All rights reserved. © 2018 International Clinical Cytometry Society.

  12. A single-platform approach using flow cytometry and microbeads to evaluate immune reconstitution in mice after bone marrow transplantation.

    PubMed

    Perruche, Sylvain; Kleinclauss, François; Lienard, Agnès; Robinet, Eric; Tiberghien, Pierre; Saas, Philippe

    2004-11-01

    The monitoring of immune reconstitution in murine models of HC transplantation, using accurate and automated methods, is necessary in view of the recent developments of hematopoietic cell (HC) transplantation (including reduced intensity conditioning regimens) as well as emerging immunological concepts (such as the involvement of dendritic cells or regulatory T cells). Here, we describe the use of a single-platform approach based on flow cytometry and tubes that contain a defined number of microbeads to evaluate absolute blood cell counts in mice. This method, previously used in humans to quantify CD34+ stem cells or CD4+ T cells in HIV infected patients, was adapted for mouse blood samples. A CD45 gating strategy in this "lyse no wash" protocol makes it possible to discriminate erythroblasts or red blood cell debris from CD45+ leukocytes, thus avoiding cell loss. Tubes contain a lyophilized brightly fluorescent microbead pellet permitting the acquisition of absolute counts of leukocytes after flow cytometric analysis. We compared this method to determine absolute counts of circulating cells with another method combining Unopette reservoir diluted blood samples, hemocytometer, microscopic examination and flow cytometry. The sensitivity of this single-platform approach was evaluated in different situations encountered in allogeneic HC transplantation, including immune cell depletion after different conditioning regimens, activation status of circulating cells after transplantation, evaluation of in vivo cell depletion and hematopoietic progenitor mobilization in the periphery. This single-platform flow cytometric assay can also be proposed to standardize murine (or other mammalian species) leukocyte count determination for physiological, pharmacological/toxicological and diagnostic applications in veterinary practice.

  13. A New Submersible Imaging-in-flow Instrument to Monitor Nano- and Microplankton: Imaging FlowCytobot

    NASA Astrophysics Data System (ADS)

    Olson, R. J.; Sosik, H. M.; Shalapyonok, A.

    2004-12-01

    Understanding of how coastal plankton communities are regulated has traditionally been limited by undersampling, but cabled observatories now provide opportunities to deploy submersible sensors that have high power and data transmission requirements. We have developed an in situ instrument to carry out high-resolution, long term monitoring of phytoplankton and microzooplankton in the size range 10 to100 micrometers, to be deployed at cabled research facilities such as the Martha's Vineyard Coastal Observatory (MVCO). The new instrument is designed to complement FlowCytobot, a submersible flow cytometer currently deployed at MVCO that uses fluorescence and light scattering signals from a laser beam to characterize the smallest phytoplankton cells (less than 10 micrometers). Imaging FlowCytobot uses a combination of flow cytometric and video technology to capture images of organisms for identification and to measure chlorophyll fluorescence associated with each image. Images will be classified using neural net software, while the measurements of chlorophyll fluorescence will allow us to discriminate heterotrophic from phototrophic cells. The new instrument, like the original FlowCytobot is autonomous but remotely programmable. It utilizes a computer controlled syringe pump and distribution valve that allows periodic anti-fouling treatment and analysis of standard beads. Samples are analyzed continuously (0.25 to 2.5 ml per min) and data is sent over a fiber optic link to a remote computer for analysis. Preliminary results indicate that we can detect cells as small as 5 micrometers and discriminate several taxa of diatoms and dinoflagellates.

  14. Quality assessment program for EuroFlow protocols: summary results of four-year (2010-2013) quality assurance rounds.

    PubMed

    Kalina, Tomas; Flores-Montero, Juan; Lecrevisse, Quentin; Pedreira, Carlos E; van der Velden, Vincent H J; Novakova, Michaela; Mejstrikova, Ester; Hrusak, Ondrej; Böttcher, Sebastian; Karsch, Dennis; Sędek, Łukasz; Trinquand, Amelie; Boeckx, Nancy; Caetano, Joana; Asnafi, Vahid; Lucio, Paulo; Lima, Margarida; Helena Santos, Ana; Bonaccorso, Paola; van der Sluijs-Gelling, Alita J; Langerak, Anton W; Martin-Ayuso, Marta; Szczepański, Tomasz; van Dongen, Jacques J M; Orfao, Alberto

    2015-02-01

    Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for

  15. Validation of radiative transfer computation with Monte Carlo method for ultra-relativistic background flow

    NASA Astrophysics Data System (ADS)

    Ishii, Ayako; Ohnishi, Naofumi; Nagakura, Hiroki; Ito, Hirotaka; Yamada, Shoichi

    2017-11-01

    We developed a three-dimensional radiative transfer code for an ultra-relativistic background flow-field by using the Monte Carlo (MC) method in the context of gamma-ray burst (GRB) emission. For obtaining reliable simulation results in the coupled computation of MC radiation transport with relativistic hydrodynamics which can reproduce GRB emission, we validated radiative transfer computation in the ultra-relativistic regime and assessed the appropriate simulation conditions. The radiative transfer code was validated through two test calculations: (1) computing in different inertial frames and (2) computing in flow-fields with discontinuous and smeared shock fronts. The simulation results of the angular distribution and spectrum were compared among three different inertial frames and in good agreement with each other. If the time duration for updating the flow-field was sufficiently small to resolve a mean free path of a photon into ten steps, the results were thoroughly converged. The spectrum computed in the flow-field with a discontinuous shock front obeyed a power-law in frequency whose index was positive in the range from 1 to 10 MeV. The number of photons in the high-energy side decreased with the smeared shock front because the photons were less scattered immediately behind the shock wave due to the small electron number density. The large optical depth near the shock front was needed for obtaining high-energy photons through bulk Compton scattering. Even one-dimensional structure of the shock wave could affect the results of radiation transport computation. Although we examined the effect of the shock structure on the emitted spectrum with a large number of cells, it is hard to employ so many computational cells per dimension in multi-dimensional simulations. Therefore, a further investigation with a smaller number of cells is required for obtaining realistic high-energy photons with multi-dimensional computations.

  16. Flow cytometric quantification of intraperitoneal free tumor cells in patients with peritoneal metastasis.

    PubMed

    Kitayama, Joji; Emoto, Shigenobu; Yamaguchi, Hironori; Ishigami, Hironori; Kamei, Takao; Yamashita, Hiroharu; Seto, Yasuyuki; Matsuzaki, Keisuke; Watanabe, Toshiaki

    2014-01-01

    Peritoneal metastasis (PM) is the most life-threatening type of metastasis in abdominal malignancy. To improve the diagnostic accuracy of cytologic detection (CY) of free tumor cells (FTC) in the peritoneal cavity, we tried to quantify the FTC to leukocyte ratio using flow cytometry in patients with peritoneal metastasis. Cells were recovered from ascites or peritoneal lavages from 106 patients who underwent abdominal surgery and additional 89 samples which were obtained from peritoneal catheter or access port in patients with PM (+) gastric cancer. The cells were immunostained with monoclonal antibodies to CD45 and to CD326 (EpCAM). Using flow cytometry, CD326 (+) and CD45 (+) cells were classified as either tumor cells (T) or leukocytes (L) and the T/L ratio (TLR) was calculated. In 106 samples obtained by laparotomy, Median (M) of the TLR of PM (+) patients was 1.39% (0-807.87%) which was significantly higher than PM (-) patients (M=0%, 0-2.14%, P < 0.001). In PM (+) patients, 86 CY (+) samples showed higher TLR than 61 CY (-) samples (M=2.81%, 0.02-1868.44% vs. M=0%, 0-3.45%, p<0.0001). In all of the 24 patients who were monitored for TLR before and after intraperitoneal (IP) chemotherapy, the TLR was reduced which was more dramatic than the results of the change in cytology. TLR measured with FACS is an excellent reflection of the tumor spread in the peritoneal cavity and could be a reliable diagnostic biomarker to determine the severity of PM as well as effectiveness of IP chemotherapy. © 2013 International Clinical Cytometry Society.

  17. Breast epithelium procurement from stereotactic core biopsy washings: flow cytometry-sorted cell count analysis.

    PubMed

    Stoler, Daniel L; Stewart, Carleton C; Stomper, Paul C

    2002-02-01

    Molecular studies of breast lesions have been constrained by difficulties in procuring adequate tissues for analyses. Standard procedures are restricted to larger, palpable masses or the use of paraffin-embedded materials, precluding facile procurement of fresh specimens of early lesions. We describe a study to determine the yield and characteristics of sorted cell populations retrieved in core needle biopsy specimen rinses from a spectrum of breast lesions. Cells from 114 consecutive stereotactic core biopsies of mammographic lesions released into saline washes were submitted for flow cytometric analysis. For each specimen, epithelial cells were separated from stromal and blood tissue based on the presence of cytokeratin 8 and 18 markers. Epithelial cell yields based on pathological diagnoses of the biopsy specimen, patient age, and mammographic appearance of the lesion were determined. Biopsies containing malignant lesions yielded significantly higher numbers of cells than were obtained from benign lesion biopsies. Significantly greater cell counts were observed from lesions from women age 50 or above compared with those of younger women. Mammographic density surrounding the biopsy site, the mammographic appearance of the lesion, and the number of cores taken at the time of biopsy appeared to have little effect on the yield of epithelial cells. We demonstrate the use of flow cytometric sorting of stereotactic core needle biopsy washes from lesions spanning the spectrum of breast pathology to obtain epithelial cells in sufficient numbers to meet the requirements of a variety of molecular and genetic analyses.

  18. Removing Background Noise with Phased Array Signal Processing

    NASA Technical Reports Server (NTRS)

    Podboy, Gary; Stephens, David

    2015-01-01

    Preliminary results are presented from a test conducted to determine how well microphone phased array processing software could pull an acoustic signal out of background noise. The array consisted of 24 microphones in an aerodynamic fairing designed to be mounted in-flow. The processing was conducted using Functional Beam forming software developed by Optinav combined with cross spectral matrix subtraction. The test was conducted in the free-jet of the Nozzle Acoustic Test Rig at NASA GRC. The background noise was produced by the interaction of the free-jet flow with the solid surfaces in the flow. The acoustic signals were produced by acoustic drivers. The results show that the phased array processing was able to pull the acoustic signal out of the background noise provided the signal was no more than 20 dB below the background noise level measured using a conventional single microphone equipped with an aerodynamic forebody.

  19. Side scatter versus CD45 flow cytometric plot can distinguish acute leukaemia subtypes.

    PubMed

    Saksena, Annapurna; Gautam, Parul; Desai, Parth; Gupta, Naresh; Dubey, A P; Singh, Tejinder

    2016-05-01

    Flow cytometry is an important tool to diagnose acute leukaemia. Attempts are being made to find the minimal number of antibodies for correctly diagnosing acute leukaemia subtypes. The present study was designed to evaluate the analysis of side scatter (SSC) versus CD45 flow dot plot to distinguish acute myeloid leukaemia (AML) from acute lymphoblastic leukaemia (ALL), with minimal immunological markers. One hundred consecutive cases of acute leukaemia were evaluated for blast cluster on SSC versus CD45 plots. The parameters studied included visual shape, CD45 and side scatter expression, continuity with residual granulocytes/lymphocytes/monocytes and ratio of maximum width to maximum height (w/h). The final diagnosis of ALL and AML and their subtypes was made by morphology, cytochemistry and immunophenotyping. Two sample Wilcoxon rank-sum (Mann Whitney) test and Kruskal-Wallis equality-of-populations rank tests were applied to elucidate the significance of the above ratios of blast cluster for diagnosis of ALL, AML and their subtypes. Receiver operating characteristic (ROC) curves were generated and the optimal cut-offs of the w/h ratio to distinguish between ALL and AML determined. Of the 100 cases, 57 of ALL and 43 cases of AML were diagnosed. The median w/h ratio of blast population was 3.8 for ALL and 1 for AML (P<0.001). ROC had area under curve of 0.9772.The optimal cut-off of the w/h ratio for distinction of ALL from AML was found to be 1.6. Our findings suggest that if w/h ratio on SSC versus CD45 plot is less than 1.6, AML may be considered, and if it is more than 1.6, ALL may be diagnosed. Using morphometric analysis of the blast cluster on SSC versus CD45, it was possible to distinguish between ALL and AML, and their subtypes.

  20. Prospective isolation of multipotent pancreatic progenitors using flow-cytometric cell sorting.

    PubMed

    Suzuki, Atsushi; Nakauchi, Hiromitsu; Taniguchi, Hideki

    2004-08-01

    During pancreatic development, neogenesis, and regeneration, stem cells might act as a central player to generate endocrine, acinar, and duct cells. Although these cells are well known as pancreatic stem cells (PSCs), indisputable proof of their existence has not been reported. Identification of phenotypic markers for PSCs leads to their prospective isolation and precise characterization to clear whether stem cells exist in the pancreas. By combining flow cytometry and clonal analysis, we show here that a possible pancreatic stem or progenitor cell candidate that resides in the developing and adult mouse pancreas expresses the receptor for the hepatocyte growth factor (HGF) c-Met, but does not express hematopoietic and vascular endothelial antigens such as CD45, TER119, c-Kit, and Flk-1. These cells formed clonal colonies in vitro and differentiated into multiple pancreatic lineage cells from single cells. Some of them could largely expand with self-renewing cell divisions in culture, and, following cell transplantation, they differentiated into pancreatic endocrine and acinar cells in vivo. Furthermore, they produced cells expressing multiple markers of nonpancreatic organs including liver, stomach, and intestine in vitro. Our data strongly suggest that c-Met/HGF signaling plays an important role in stem/progenitor cell function in both developing and adult pancreas. By using this antigen, PSCs could be isolated prospectively, enabling a detailed investigation of stem cell markers and application toward regenerative therapies for diabetes.

  1. Flow cytometric analysis of BDE 47 mediated injury to rainbow trout gill epithelial cells

    PubMed Central

    Shao, Jing; Dabrowski, Michael J.; White, Collin C.; Kavanagh, Terrance J.; Gallagher, Evan P.

    2012-01-01

    The polybrominated diphenyl ethers (PBDEs) are ubiquitous environmental contaminants whose residues are increasing in fish, wildlife and human tissues. However, relatively little is known regarding the mechanisms of cell injury caused by PBDE congeners in fish. In the present study, we employed flow cytometry-based analyses to understand the onset and mechanisms of cell injury in rainbow trout gill cells (RTgill-W1 cells) exposed to 2,2′,4,4′-tetrabromodiphenyl ether (BDE 47). Substantial optimization and validation for flow cytometry protocols were required during assay development for the trout gill cell line. Exposure to micromolar concentrations of BDE 47 elicited a significant loss in RTgill-W1 cell viability that was accompanied by a decrease in NAD(P)H autofluorescence, a marker associated with disruption of cellular redox status. This loss in NAD(P)H content was accompanied by a decrease in nonylacridine orange fluorescence, indicating mitochondrial membrane lipid peroxidation. Furthermore, low doses of BDE 47 altered cellular forward angle light scatter (FS, a measure of cell diameter or size) and side light scatter properties (SS, a measure of cellular internal complexity), consistent with the early stages of apoptosis. These changes were more pronounced at higher BDE 47 concentrations, which lead to an increase in the percentage of cells undergoing frank apoptosis as evidenced by sub-G1 DNA content. Apoptosis was also observed at a relatively low dose (3.2 μM) of BDE 47 if cells were exposed for an extended period of time (24 hr). Collectively, the results of these studies indicate that exposure of rainbow trout gill cells to BDE47 is associated with the induction of apoptosis likely originating from disruption of cellular redox status and mitochondrial oxidative injury. The current report extends observations in other species demonstrating that oxidative stress is an important mechanism of BDE 47 mediated cellular toxicity, and supports the use of

  2. Optimization and Standardization of Fluorescent Cell Barcoding for Multiplexed Flow Cytometric Phenotyping

    PubMed Central

    Giudice, Valentina; Feng, Xingmin; Kajigaya, Sachiko; Young, Neal S.; Biancotto, Angélique

    2017-01-01

    Fluorescent cell barcoding (FCB) is a cell-based multiplexing technique for high-throughput flow cytometry. Barcoded samples can be stained and acquired collectively, minimizing staining variability and antibody consumption, and decreasing required sample volumes. Combined with functional measurements, FCB can be used for drug screening, signaling profiling, and cytokine detection, but technical issues are present. We optimized the FCB technique for routine utilization using DyLight 350, DyLight 800, Pacific Orange, and CBD500 for barcoding six, nine, or 36 human peripheral blood specimens. Working concentrations of FCB dyes ranging from 0 to 500 μg/ml were tested, and viability dye staining was optimized to increase robustness of data. A five-color staining with surface markers for Vβ usage analysis in CD4+ and CD8+ T cells was achieved in combination with nine sample barcoding. We provide improvements of the FCB technique that should be useful for multiplex drug screening and for lymphocyte characterization and perturbations in the diagnosis and during the course of disease. PMID:28692789

  3. Flow cytomeric measurement of DNA and incorporated nucleoside analogs

    DOEpatents

    Dolbeare, Frank A.; Gray, Joe W.

    1989-01-01

    A method is provided for simultaneously measuring total cellular DNA and incorporated nucleoside analog. The method entails altering the cellular DNA of cells grown in the presence of a nucleoside analog so that single stranded and double stranded portions are present. Separate stains are used against the two portions. An immunochemical stain is used against the single stranded portion to provide a measure of incorporated nucleoside analog, and a double strand DNA-specific stain is used against the double stranded portion to simultaneously provide a measure of total cellular DNA. The method permits rapid flow cytometric analysis of cell populations, rapid identification of cycling and noncycling subpopulations, and determination of the efficacy of S phase cytotoxic anticancer agents.

  4. Background Oriented Schlieren Using Celestial Objects

    NASA Technical Reports Server (NTRS)

    Haering, Edward, A., Jr. (Inventor); Hill, Michael A (Inventor)

    2017-01-01

    The present invention is a system and method of visualizing fluid flow around an object, such as an aircraft or wind turbine, by aligning the object between an imaging system and a celestial object having a speckled background, taking images, and comparing those images to obtain fluid flow visualization.

  5. Flow cytometric analysis of regulatory T cells during hyposensitization of acquired allergic contact dermatitis.

    PubMed

    Fraser, Kathleen; Abbas, Mariam; Hull, Peter R

    2014-01-01

    We previously demonstrated that repeated intradermal steroid injections administered at weekly intervals into positive patch-test sites induce hyposensitization and desensitization. To examine changes in CD4CD25CD127lo/ regulatory T cells during the attenuation of the patch-test response. Ten patients with known allergic contact dermatitis were patch tested weekly for 10 weeks. The patch-test site was injected intradermally with 2 mg triamcinolone. At weeks 1 and 7, a biopsy was performed on the patch-test site in 6 patients, and flow cytometry was performed assessing CD4CD25CD127lo/ regulatory T cells. Secondary outcomes were clinical score, reaction size, erythema, and temperature. Statistical analysis included regression, correlation, and repeated-measures analysis of variance. The percentage of CD4CD25CD127lo/ regulatory T cells, measured by flow cytometry, increased from week 1 to week 7 by an average of 19.2%. The average grade of patch-test reaction decreased from +++ (vesicular reaction) to ++ (palpable erythema). The mean drop in temperature following treatment was 0.28°C per week. The mean area decreased 8.6 mm/wk over 10 weeks. Intradermal steroid injections of weekly patch-test reactions resulted in hyposensitization of the allergic contact dermatitis reaction. CD4CD25CD127lo/ regulatory T cells showed a tendency to increase; however, further studies are needed to determine if this is significant.

  6. Construction of BAC Libraries from Flow-Sorted Chromosomes.

    PubMed

    Šafář, Jan; Šimková, Hana; Doležel, Jaroslav

    2016-01-01

    Cloned DNA libraries in bacterial artificial chromosome (BAC) are the most widely used form of large-insert DNA libraries. BAC libraries are typically represented by ordered clones derived from genomic DNA of a particular organism. In the case of large eukaryotic genomes, whole-genome libraries consist of a hundred thousand to a million clones, which make their handling and screening a daunting task. The labor and cost of working with whole-genome libraries can be greatly reduced by constructing a library derived from a smaller part of the genome. Here we describe construction of BAC libraries from mitotic chromosomes purified by flow cytometric sorting. Chromosome-specific BAC libraries facilitate positional gene cloning, physical mapping, and sequencing in complex plant genomes.

  7. Event plane dependence of the flow modulated background in dihadron and jet-hadron correlations in heavy ion collisions

    NASA Astrophysics Data System (ADS)

    Nattrass, Christine; Todoroki, Takahito

    2018-05-01

    Dihadron and jet-hadron correlationsare commonly used in relativistic heavy ion collisions to study the soft component of jets in a quark gluon plasma. There is a large correlated background which is described by the Fourier decomposition of the azimuthal anisotropy where vn is the n th order coefficient. The path length dependence of partonic energy loss can be studied by varying the angle of the high momentum trigger particle or jet relative to a reconstructed event plane. This modifies the shape of the background correlated with that event plane. The original derivation of the shape of this background only considered correlations relative to the second-order event plane, which is correlated to the initial participant plane. We derive the shape of this background for an event plane at an arbitrary order. There is a phase shift in the case of jets restricted to asymmetric regions relative to the event plane. For realistic correlations between event planes, the correlation between the second- and fourth-order event planes leads to a much smaller effect than the finite event plane resolution at each order. Finally, we assess the status of the rapidity even v1 term due to flow, which has been measured to be comparable to v2 and v3 terms.

  8. Effects of background motion on eye-movement information.

    PubMed

    Nakamura, S

    1997-02-01

    The effect of background stimulus on eye-movement information was investigated by analyzing the underestimation of the target velocity during pursuit eye movement (Aubert-Fleishl paradox). In the experiment, a striped pattern with various brightness contrasts and spatial frequencies was used as a background stimulus, which was moved at various velocities. Analysis showed that the perceived velocity of the pursuit target, which indicated the magnitudes of eye-movement information, decreased when the background stripes moved in the same direction as eye movement at higher velocities and increased when the background moved in the opposite direction. The results suggest that the eye-movement information varied as a linear function of the velocity of the motion of the background retinal image (optic flow). In addition, the effectiveness of optic flow on eye-movement information was determined by the attributes of the background stimulus such as the brightness contrast or the spatial frequency of the striped pattern.

  9. Fluid dynamic propagation of initial baryon number perturbations on a Bjorken flow background

    DOE PAGES

    Floerchinger, Stefan; Martinez, Mauricio

    2015-12-11

    Baryon number density perturbations offer a possible route to experimentally measure baryon number susceptibilities and heat conductivity of the quark gluon plasma. We study the fluid dynamical evolution of local and event-by-event fluctuations of baryon number density, flow velocity, and energy density on top of a (generalized) Bjorken expansion. To that end we use a background-fluctuation splitting and a Bessel-Fourier decomposition for the fluctuating part of the fluid dynamical fields with respect to the azimuthal angle, the radius in the transverse plane, and rapidity. Here, we examine how the time evolution of linear perturbations depends on the equation of statemore » as well as on shear viscosity, bulk viscosity, and heat conductivity for modes with different azimuthal, radial, and rapidity wave numbers. Finally we discuss how this information is accessible to experiments in terms of the transverse and rapidity dependence of correlation functions for baryonic particles in high energy nuclear collisions.« less

  10. Deciphering the mechanisms of cellular uptake of engineered nanoparticles by accurate evaluation of internalization using imaging flow cytometry

    PubMed Central

    2013-01-01

    Background The uptake of nanoparticles (NPs) by cells remains to be better characterized in order to understand the mechanisms of potential NP toxicity as well as for a reliable risk assessment. Real NP uptake is still difficult to evaluate because of the adsorption of NPs on the cellular surface. Results Here we used two approaches to distinguish adsorbed fluorescently labeled NPs from the internalized ones. The extracellular fluorescence was either quenched by Trypan Blue or the uptake was analyzed using imaging flow cytometry. We used this novel technique to define the inside of the cell to accurately study the uptake of fluorescently labeled (SiO2) and even non fluorescent but light diffracting NPs (TiO2). Time course, dose-dependence as well as the influence of surface charges on the uptake were shown in the pulmonary epithelial cell line NCI-H292. By setting up an integrative approach combining these flow cytometric analyses with confocal microscopy we deciphered the endocytic pathway involved in SiO2 NP uptake. Functional studies using energy depletion, pharmacological inhibitors, siRNA-clathrin heavy chain induced gene silencing and colocalization of NPs with proteins specific for different endocytic vesicles allowed us to determine macropinocytosis as the internalization pathway for SiO2 NPs in NCI-H292 cells. Conclusion The integrative approach we propose here using the innovative imaging flow cytometry combined with confocal microscopy could be used to identify the physico-chemical characteristics of NPs involved in their uptake in view to redesign safe NPs. PMID:23388071

  11. Detection of bacterial contamination in platelet concentrates by a sensitive flow cytometric assay (BactiFlow): a multicentre validation study.

    PubMed

    Vollmer, T; Dreier, J; Schottstedt, V; Bux, J; Tapernon, K; Sibrowski, W; Kleesiek, K; Knabbe, C

    2012-08-01

    Bacterial contamination of platelet concentrates (PCs) still represents an ongoing risk. As a result of septic complications, particularly observed with older PCs, the shelf life of PCs has been reduced in Germany to 4 days. In this study, bacterial screening of PCs by BactiFlow (BF) flow cytometry was introduced in three German blood services to evaluate the robustness and applicability of the assay. Results were used to discuss the potential for the extension of PC shelf life to 5 days. A total of 1956 PCs were tested on days 4 or 5+ after PC production using the BF, whereas the BacT/Alert culture system served as reference method. Two PCs were confirmed positive by culture only and were identified as Propionibacterium acnes and Staphylococcus species. Two PCs were confirmed positive for Streptococcus mitis by BF and culture. Additionally, two PCs were culture-positive only in one culture bottle (aerobic: S. mitis and anaerobic: S. hominis). Retrospective analysis of bacterial growth kinetics provide the indication that corresponding bacterial titres were most likely below the BF analytical detection limit (<150 CFU mL(-1) ) and had probably no transfusion relevance. All remaining specimens were tested negative. Testing of PCs by BF was successfully implemented. The BF proved sufficient as a rapid screening method to improve PC safety. This study further provides data supporting the extension of PC shelf life to 5 days after negative BF testing on day 4. © 2012 The Authors. Transfusion Medicine © 2012 British Blood Transfusion Society.

  12. FLOCK cluster analysis of plasma cell flow cytometry data predicts bone marrow involvement by plasma cell neoplasia.

    PubMed

    Dorfman, David M; LaPlante, Charlotte D; Li, Betty

    2016-09-01

    We analyzed plasma cell populations in bone marrow samples from 353 patients with possible bone marrow involvement by a plasma cell neoplasm, using FLOCK (FLOw Clustering without K), an unbiased, automated, computational approach to identify cell subsets in multidimensional flow cytometry data. FLOCK identified discrete plasma cell populations in the majority of bone marrow specimens found by standard histologic and immunophenotypic criteria to be involved by a plasma cell neoplasm (202/208 cases; 97%), including 34 cases that were negative by standard flow cytometric analysis that included clonality assessment. FLOCK identified discrete plasma cell populations in only a minority of cases negative for involvement by a plasma cell neoplasm by standard histologic and immunophenotypic criteria (38/145 cases; 26%). Interestingly, 55% of the cases negative by standard analysis, but containing a FLOCK-identified discrete plasma cell population, were positive for monoclonal gammopathy by serum protein electrophoresis and immunofixation. FLOCK-identified and quantitated plasma cell populations accounted for 3.05% of total cells on average in cases positive for involvement by a plasma cell neoplasm by standard histologic and immunophenotypic criteria, and 0.27% of total cells on average in cases negative for involvement by a plasma cell neoplasm by standard histologic and immunophenotypic criteria (p<0.0001; area under the curve by ROC analysis=0.96). The presence of a FLOCK-identified discrete plasma cell population was predictive of the presence of plasma cell neoplasia with a sensitivity of 97%, compared with only 81% for standard flow cytometric analysis, and had specificity of 74%, PPV of 84% and NPV of 95%. FLOCK analysis, which has been shown to provide useful diagnostic information for evaluating patients with suspected systemic mastocytosis, is able to identify neoplastic plasma cell populations analyzed by flow cytometry, and may be helpful in the diagnostic

  13. A brief history of numbers and statistics with cytometric applications.

    PubMed

    Watson, J V

    2001-02-15

    A brief history of numbers and statistics traces the development of numbers from prehistory to completion of our current system of numeration with the introduction of the decimal fraction by Viete, Stevin, Burgi, and Galileo at the turn of the 16th century. This was followed by the development of what we now know as probability theory by Pascal, Fermat, and Huygens in the mid-17th century which arose in connection with questions in gambling with dice and can be regarded as the origin of statistics. The three main probability distributions on which statistics depend were introduced and/or formalized between the mid-17th and early 19th centuries: the binomial distribution by Pascal; the normal distribution by de Moivre, Gauss, and Laplace, and the Poisson distribution by Poisson. The formal discipline of statistics commenced with the works of Pearson, Yule, and Gosset at the turn of the 19th century when the first statistical tests were introduced. Elementary descriptions of the statistical tests most likely to be used in conjunction with cytometric data are given and it is shown how these can be applied to the analysis of difficult immunofluorescence distributions when there is overlap between the labeled and unlabeled cell populations. Copyright 2001 Wiley-Liss, Inc.

  14. A multicolor flow cytometric assay for measurement of platelet-derived microparticles.

    PubMed

    Mobarrez, Fariborz; Antovic, Jovan; Egberg, Nils; Hansson, Mona; Jörneskog, Gun; Hultenby, Kjell; Wallén, Håkan

    2010-03-01

    Flow cytometry (FCM) is the most commonly used method for detection of platelet-derived microparticles (PDMPs), but it is poorly standardized and mainly used for "bedside" analyses in fresh samples. If PDMPs could be analyzed in previously frozen samples it would increase the usefulness of the method. However, cell membrane fragments from contaminating cells created during freezing/thawing may cause artifacts and disturb measurements. PDMPs were labeled with monoclonal antibodies directed against CD42a and CD62P, or CD42a and CD142. The PDMP gate was determined using forward scatter (FSC) and CD42a expression. The mean fluorescence intensities (MFIs) of CD62P or CD142 positive particles were translated into MESF -values (Molecules of Equivalent Soluble Fluorochrome) using a standard curve. FITC-labeled phalloidin (which binds to intracellular actin) was used to detect destroyed cells/cell fragments. Phalloidin-positive particles were significantly more common in supernatants of frozen/thawed platelet rich and platelet poor plasma samples compared with supernatants of platelet free plasma. High-speed centrifugation was then used to obtain PDMP samples with low contamination of cell fragments. Electron microscopy showed that these samples contained numerous round stained particles with cellular membranes of a size of 100-700 nm. Reproducibility experiments using plasma samples from healthy individuals showed that the coefficients of variation (CVs) of MESF values of CD62P and CD142 (both intra- and interassay) were <10%, and the variation between two cytometers in two different laboratories was <5%. We also found that PDMP expression of CD142 (i.e. tissue factor [TF]) and CD62P (i.e P-selectin) was around two times higher in samples from type 1-diabetes patients compared with those from healthy controls (p<0.001). The use of MESF values to quantify PDMP expression of P-selectin and TF yields reproducible data and enables comparison of data between laboratories. If

  15. Flow cytometric evaluation of antibiotic effects on viability and mitochondrial function of refrigerated spermatozoa of Nile tilapia

    USGS Publications Warehouse

    Segovia, M.; Jenkins, J.A.; Paniagua-Chavez, C.; Tiersch, T.R.

    2000-01-01

    Improved techniques for storage and evaluation of fish sperm would enhance breeding programs around the world. The goal of this study was to test the effect of antibiotics on refrigerated sperm from Nile tilapia (Oreochromis niloticus) by use of flow cytometry with 2 dual-staining protocols for objective assessment of sperm quality. Concentrations of 1 x 109 sperm/mL were suspended in Ringer's buffer at 318 mOsmol/kg (pH 8.0). The fluorescent stains Sybr 14 (10 ??M), propidium iodide (2.4 mM), and rhodamine 123 (0.13 ??M) were used to assess cell viability and mitochondrial function. Three concentrations of ampicillin, gentamicin, and an antibiotic/antimycotic solution were added to fresh spermatozoa. Motility estimates and flow cytometry measurements were made daily during 7 d of refrigerated storage (4 ??C). The highest concentrations of gentamicin and antibiotic/antimycotic and all 3 concentrations of ampicillin significantly reduced sperm viability. The highest of each of the 3 antibiotic concentrations significantly reduced mitochondrial function. This study demonstrates that objective sperm quality assessments can be made using flow cytometry and that addition of antibiotics at appropriate concentrations can lengthen refrigerated storage time for tilapia spermatozoa. With minor modifications, these protocols can be adapted for use with sperm from other species and with other tissue types.

  16. High throughput, parallel imaging and biomarker quantification of human spermatozoa by ImageStream flow cytometry.

    PubMed

    Buckman, Clayton; George, Thaddeus C; Friend, Sherree; Sutovsky, Miriam; Miranda-Vizuete, Antonio; Ozanon, Christophe; Morrissey, Phil; Sutovsky, Peter

    2009-12-01

    Spermatid specific thioredoxin-3 protein (SPTRX-3) accumulates in the superfluous cytoplasm of defective human spermatozoa. Novel ImageStream technology combining flow cytometry with cell imaging was used for parallel quantification and visualization of SPTRX-3 protein in defective spermatozoa of five men from infertile couples. The majority of the SPTRX-3 containing cells were overwhelmingly spermatozoa with a variety of morphological defects, detectable in the ImageStream recorded images. Quantitative parameters of relative SPTRX-3 induced fluorescence measured by ImageStream correlated closely with conventional flow cytometric measurements of the same sample set and reflected the results of clinical semen evaluation. Image Stream quantification of SPTRX-3 combines and surpasses the informative value of both conventional flow cytometry and light microscopic semen evaluation. The observed patterns of the retention of SPTRX-3 in the sperm samples from infertility patients support the view that SPTRX3 is a biomarker of male infertility.

  17. Study of NGEP expression in androgen sensitive prostate cancer cells: A potential target for immunotherapy

    PubMed Central

    Mohsenzadegan, Monireh; Tajik, Nader; Madjd, Zahra; Shekarabi, Mehdi; Farajollahi, Mohammad M

    2015-01-01

    Background: Prostate cancer is one of the leading causes of cancer deaths among men. New gene expressed in prostate (NGEP), is a prostate-specific gene expressed only in normal prostate and prostate cancer tissue. Because of its selective expression in prostate cancer cell surface, NGEP is a potential immunotherapeutic target. To target the NGEP in prostate cancer, it is essential to investigate its expression in prostate cancer cells. Methods: In the present study, we investigated NGEP expression in LNCaP and DU145 cells by real time and RT-PCR, flow cytometric and immunocytochemical analyses. Results: Real time and RT-PCR analyses of NGEP expression showed that NGEP was expressed in the LNCaP cells but not in DU145 cells. The detection of NGEP protein by flow cytometric and immunocytochemistry analyses indicated that NGEP protein was weakly expressed only in LNCaP cell membrane. Conclusion: Our results demonstrate that LNCaP cell line is more suitable than DU145 for NGEP expression studies; however, its low-level expression is a limiting issue. NGEP expression may be increased by androgen supplementation of LNCaP cell culture medium. PMID:26000254

  18. Detection of acute lymphoblastic leukemia involvement in pleural fluid in an adult patient with ataxia telangiectasia by flow cytometry method.

    PubMed

    Keklik, Muzaffer; Koker, M Yavuz; Sivgin, Serdar; Camlica, Demet; Pala, Cigdem; Cetin, Mustafa; Kaynar, Leylagul; Unal, Ali; Eser, Bulent

    2014-09-01

    Ataxia-telangiectasia (AT) is a rare multisystem, neurodegenerative genetic disorder. Patients should be closely monitored due to risk of malignancy development. Due to its wide clinical heterogeneity, it often leads physicians to an inaccurate or missed diagnosis, and insight into this rare disease is important. Pediatric patients may develop lymphomas and acute lymphoblastic leukemia (ALL). However, in adults, there are limited numbers of reports regarding association of AT and ALL. Rarely, ALL cases may present with pleural fluid involvement. In our study, we presented an adult case with AT, in which ALL involvement was detected in pleural fluid by flow cytometry (FC). A 20-years old male presented to emergency department with fever, shortness of breath and cough, as he had been followed with a diagnosis of AT. The following findings were detected in laboratory tests: Hb, 11.5 g/L; WBC, 36 × 10(9)/L; Plt: 140 × 10(9)/L. Blastic cells were observed in peripheral blood smear. On chest radiography, pleural fluid appearance was observed. On thorax CT, pleural fluid was detected in both hemithorax. Cytoplasmic CD3(+) and superficial CD3 (+), CD45 (+), CD5 (+), CD7 (+) and CD38 (+) was found in the flow cytometric evaluation of peripheral blood. Superficial CD3 (+), CD2 (+), CD5 (+) and CD7 (+) were found in flow cytometric evaluation of pleural fluid. These findings were considered as consistent with pleural involvement of T-ALL. FC is a potentially useful diagnostic tool for clinical practice and it is a convenience method which has an important role in detection of ALL in patients with pleural fluid.

  19. Time-gated flow cytometry: an ultra-high selectivity method to recover ultra-rare-event μ-targets in high-background biosamples

    NASA Astrophysics Data System (ADS)

    Jin, Dayong; Piper, James A.; Leif, Robert C.; Yang, Sean; Ferrari, Belinda C.; Yuan, Jingli; Wang, Guilan; Vallarino, Lidia M.; Williams, John W.

    2009-03-01

    A fundamental problem for rare-event cell analysis is auto-fluorescence from nontarget particles and cells. Time-gated flow cytometry is based on the temporal-domain discrimination of long-lifetime (>1 μs) luminescence-stained cells and can render invisible all nontarget cell and particles. We aim to further evaluate the technique, focusing on detection of ultra-rare-event 5-μm calibration beads in environmental water dirt samples. Europium-labeled 5-μm calibration beads with improved luminescence homogeneity and reduced aggregation were evaluated using the prototype UV LED excited time-gated luminescence (TGL) flow cytometer (FCM). A BD FACSAria flow cytometer was used to sort accurately a very low number of beads (<100 events), which were then spiked into concentrated samples of environmental water. The use of europium-labeled beads permitted the demonstration of specific detection rates of 100%+/-30% and 91%+/-3% with 10 and 100 target beads, respectively, that were mixed with over one million nontarget autofluorescent background particles. Under the same conditions, a conventional FCM was unable to recover rare-event fluorescein isothiocyanate (FITC) calibration beads. Preliminary results on Giardia detection are also reported. We have demonstrated the scientific value of lanthanide-complex biolabels in flow cytometry. This approach may augment the current method that uses multifluorescence-channel flow cytometry gating.

  20. Biology and flow cytometry of proangiogenic hematopoietic progenitors cells.

    PubMed

    Rose, Jonathan A; Erzurum, Serpil; Asosingh, Kewal

    2015-01-01

    During development, hematopoiesis and neovascularization are closely linked to each other via a common bipotent stem cell called the hemangioblast that gives rise to both hematopoietic cells and endothelial cells. In postnatal life, this functional connection between the vasculature and hematopoiesis is maintained by a subset of hematopoietic progenitor cells endowed with the capacity to differentiate into potent proangiogenic cells. These proangiogenic hematopoietic progenitors comprise a specific subset of bone marrow (BM)-derived cells that homes to sites of neovascularization and possess potent paracrine angiogenic activity. There is emerging evidence that this subpopulation of hematopoietic progenitors plays a critical role in vascular health and disease. Their angiogenic activity is distinct from putative "endothelial progenitor cells" that become structural cells of the endothelium by differentiation into endothelial cells. Proangiogenic hematopoietic progenitor cell research requires multidisciplinary expertise in flow cytometry, hematology, and vascular biology. This review provides a comprehensive overview of proangiogenic hematopoietic progenitor cell biology and flow cytometric methods to detect these cells in the peripheral blood circulation and BM. © 2014 International Society for Advancement of Cytometry.

  1. Multiplexed immunophenotyping of human antigen-presenting cells in whole blood by polychromatic flow cytometry

    PubMed Central

    Fung, Erik; Esposito, Laura; Todd, John A.; Wicker, Linda S.

    2010-01-01

    We describe two modular protocols for immunostaining and multiparameter flow cytometric analysis of major human antigen-presenting cells (dendritic cells, monocytes, B lymphocytes) in minimally manipulated whole blood. Simultaneous detection of up to eight colors is enabled by careful selection and testing of cell-subset-defining monoclonal antibodies (anchor markers) in the appropriate fluorochrome combinations, to demonstrate the quantification of surface expression levels of molecules involved in chemotaxis (e.g. CX3CR1, CCR2), adhesion (e.g. CD11b, CD62L), antigen presentation (e.g. CD83, CD86, CD209) and immune regulation (e.g. CD101) on circulating antigen-presenting cells. Each immunostaining reaction requires as little as 50–100 μl of peripheral whole blood, no density-gradient separation, and the entire procedure from preparation of reagents to flow cytometry can be completed in <5 h. PMID:20134434

  2. Normal adult ramified microglia separated from other central nervous system macrophages by flow cytometric sorting: Phenotypic differences defined and direct ex vivo antigen presentation to myelin basic protein-reactive CD4{sup +} T cells compared

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, A.L.; Goodsall, A.L.; Sedgwick, J.D.

    1995-05-01

    Ramified microglia in the adult central nervous system (CNS) are the principal glial element up-regulating MHC class I and II expression in response to inflammatory events or neuronal damage. A proportion of these cells also express MHC class II constitutively in the normal CNS. The role of microglia as APCs for CD4{sup +} cells extravasating into the CNS remains undefined. In this study, using irradiation bone marrow chimeras in CD45-congenic rats, the phenotype CD45{sup low}CD11b/c{sup +} is shown to identify microglial cells specifically within the CNS. Highly purified populations of microglia and nonmicroglial but CNS-associated macrophages (CD45{sup high}CD11b/c{sup +}) havemore » been obtained directly from the adult CNS, by using flow cytometric sorting. Morphologically, freshly isolated microglia vs other CNS macrophages are quite distinct. Of the two populations recovered from the normal CNS, it is the minority CD45{sup high}CD11 b/c{sup +} transitional macrophage population, and not microglia, that is the effective APC for experimental autoimmune encephalomyelitis-inducing CD4{sup +} myelin basic protein (MBP)-reactive T cells. CD45{sup high}CD11b/c{sup +} CNS macrophages also stimulate MBP-reactive T cells without addition of MBP to culture suggesting presentation of endogenous Ag. This is the first study in which microglia vs other CNS macrophages have been analyzed for APC ability directly from the CNS, with substantial cross-contamination between the two populations eliminated. The heterogeneity of these populations in terms of APC function is clearly demonstrated. Evidence is still lacking that adult CNS microglia have the capacity to interact with and stimulate CD4{sup +} T cells to proliferate or secrete IL-2. 60 refs., 6 figs., 1 tab.« less

  3. Application of upconversion luminescent-magnetic microbeads with weak background noise and facile separation in ochratoxin A detection

    NASA Astrophysics Data System (ADS)

    Liao, Zhenyu; Zhang, Ying; Su, Lin; Chang, Jin; Wang, Hanjie

    2017-02-01

    Ochratoxin A (OTA), the most harmful and abundant ochratoxin, is chemically stable and commonly existed in foodstuffs. In this work, upconversion luminescent-magnetic microbeads (UCLMMs) -based cytometric bead array for OTA detection with a less reagent consumption and high sensitivity has been established and optimized. In UCLMMs, upconversion nanocrystals (UCNs) for optical code present a weak background noise and no spectral cross talk between the encoding signals and target labels under two excitation conditions to improve detection sensitivity. While the superparamagnetic Fe3O4 nanoparticles (Fe3O4 NPs) aim for rapid analysis. The results show that the developed method has a sensitivity of 9.553 ppt below HPLC with a 50-μL sample and can be completed in <2 h with good accuracy and high reproducibility. Therefore, different colors of UCLMMs will become a promising assay platform for multiple mycotoxins after further improvement.

  4. Super-resolved calibration-free flow cytometric characterization of platelets and cell-derived microparticles in platelet-rich plasma.

    PubMed

    Konokhova, Anastasiya I; Chernova, Darya N; Moskalensky, Alexander E; Strokotov, Dmitry I; Yurkin, Maxim A; Chernyshev, Andrei V; Maltsev, Valeri P

    2016-02-01

    Importance of microparticles (MPs), also regarded as extracellular vesicles, in many physiological processes and clinical conditions motivates one to use the most informative and precise methods for their characterization. Methods based on individual particle analysis provide statistically reliable distributions of MP population over characteristics. Although flow cytometry is one of the most powerful technologies of this type, the standard forward-versus-side-scattering plots of MPs and platelets (PLTs) overlap considerably because of similarity of their morphological characteristics. Moreover, ordinary flow cytometry is not capable of measurement of size and refractive index (RI) of MPs. In this study, we 1) employed the potential of the scanning flow cytometer (SFC) for identification and characterization of MPs from light scattering; 2) suggested the reference method to characterize MP morphology (size and RI) with high precision; and 3) determined the lowest size of a MP that can be characterized from light scattering with the SFC. We equipped the SFC with 405 and 488 nm lasers to measure the light-scattering profiles and side scattering from MPs, respectively. The developed two-stage method allowed accurate separation of PLTs and MPs in platelet-rich plasma. We used two optical models for MPs, a sphere and a bisphere, in the solution of the inverse light-scattering problem. This solution provides unprecedented precision in determination of size and RI of individual spherical MPs-median uncertainties (standard deviations) were 6 nm and 0.003, respectively. The developed method provides instrument-independent quantitative information on MPs, which can be used in studies of various factors affecting MP population. © 2015 International Society for Advancement of Cytometry.

  5. Measurement of Lipid Accumulation in Chlorella vulgaris via Flow Cytometry and Liquid-State ¹H NMR Spectroscopy for Development of an NMR-Traceable Flow Cytometry Protocol

    PubMed Central

    Bono Jr., Michael S.; Garcia, Ravi D.; Sri-Jayantha, Dylan V.; Ahner, Beth A.; Kirby, Brian J.

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r 2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols. PMID:26267664

  6. Measurement of lipid accumulation in Chlorella vulgaris via flow cytometry and liquid-state ¹H NMR spectroscopy for development of an NMR-traceable flow cytometry protocol.

    PubMed

    Bono, Michael S; Garcia, Ravi D; Sri-Jayantha, Dylan V; Ahner, Beth A; Kirby, Brian J

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols.

  7. Monitoring of Legionella pneumophila viability after chlorine dioxide treatment using flow cytometry.

    PubMed

    Mustapha, Pascale; Epalle, Thibaut; Allegra, Séverine; Girardot, Françoise; Garraud, Olivier; Riffard, Serge

    2015-04-01

    The viability of three Legionella pneumophila strains was monitored after chlorine dioxide (ClO2) treatment using a flow cytometric assay. Suspensions of L. pneumophila cells were submitted to increasing concentrations of ClO2. Culturable cells were still detected when using 4 mg/L, but could no longer be detected after exposure to 6 mg/L of ClO2, although viable but not culturable (VBNC) cells were found after exposure to 4-5 mg/L of ClO2. When testing whether these VBNC were infective, two of the strains were resuscitated after co-culture with Acanthamoeba polyphaga, but neither of them could infect macrophage-like cells. Copyright © 2015 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  8. A multicolour flow cytometric assay for c-MYC protein in B-cell lymphoma.

    PubMed

    Alayed, Khaled; Schweitzer, Karen; Awadallah, Amad; Shetty, Shashirekha; Turakhia, Samir; Meyerson, Howard

    2018-05-16

    Develop an objective assay to detect c-MYC protein expression using multiparametric flow cytometry (FCM) as an alternative to immunohistochemistry (IHC). 57 patient samples and 11 cell line samples were evaluated. Cell suspensions were obtained and c-MYC staining was performed in combination with CD45 and CD19 and, in some samples, CD10. The percentage of c-MYC+ cells by FCM was correlated with the percentage determined by IHC. The relationship between c-MYC protein expression and the presence of a c-MYC gene rearrangement in aggressive and high-grade lymphomas was also assessed. c-MYC expression by FCM and IHC demonstrated a high degree of correlation in a training set of 33 patient cases, r=0.92, 11 cell line samples, r=0.81 and in a validation set of 24 aggressive and high-grade B-cell lymphomas, r=0.85. c-MYC gene was rearranged by fluorescence in situ hybridisation in 6/9 samples with high c-MYC expression (>40%) by FCM and 6/14 by IHC. We have developed a reliable multicolour FCM assay to detect c-MYC expression suitable for clinical laboratories that should be helpful to accurately quantify c-MYC expression in B-cell lymphomas. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. The use of isotypic control antibodies in the analysis of CD3+ and CD3+, CD4+ lymphocyte subsets by flow cytometry. Are they really necessary?

    PubMed

    Sreenan, J J; Tbakhi, A; Edinger, M G; Tubbs, R R

    1997-02-01

    Isotypic control reagents are defined as irrelevant antibodies of the same immunoglobulin class as the relevant reagent antibody in a flow cytometry panel. The use of the isotypic control antibody has been advocated as a necessary quality control measure in analysis of flow cytometry. The purpose of this study was to determine the necessity of an isotypic control antibody in the analysis of CD3+ and CD3+, CD4+ lymphocyte subsets. We performed a prospective study of 46 consecutive patient samples received for lymphocyte subset analysis to determine the need for the isotypic control. For each sample, a sham buffer (autocontrol) and isotypic control reagent were stained for three-color immunofluorescence, processed, and identically analyzed with Attractors software. The Attractors software allowed independent, multiparametric, simultaneous gating; was able to identically and reproducibly process each list mode file; and yielded population data in spreadsheet form. Statistical analysis (Fisher's z test) revealed no difference between the CD3+ autocontrol and CD3+ isotypic control (correlation = 1, P < .0001) or between the CD3+, CD4+ autocontrol and the CD3+, CD4+ isotypic control (correlation = 1, P < .0001). The elimination of the isotypic control reagent resulted in a total cost savings of $3.36 per test. Additionally, the subtraction of isotypic background can artifactually depress population enumeration. The use of an isotypic control antibody is not necessary to analyze flow cytometric data that result in discrete cell populations, such as CD3+ and CD3+, CD4+ lymphocyte subsets. The elimination of this unnecessary quality control measure results in substantial cost savings.

  10. Flow cytometric sorting of fecal bacteria after in situ hybridization with polynucleotide probes.

    PubMed

    Bruder, Lena M; Dörkes, Marcel; Fuchs, Bernhard M; Ludwig, Wolfgang; Liebl, Wolfgang

    2016-10-01

    The gut microbiome represents a key contributor to human physiology, metabolism, immune function, and nutrition. Elucidating the composition and genetics of the gut microbiota under various conditions is essential to understand how microbes function individually and as a community. Metagenomic analyses are increasingly used to study intestinal microbiota. However, for certain scientific questions it is sufficient to examine taxon-specific submetagenomes, covering selected bacterial genera in a targeted manner. Here we established a new variant of fluorescence in situ hybridization (FISH) combined with fluorescence-activated cell sorting (FACS), providing access to the genomes of specific taxa belonging to the complex community of the intestinal microbiota. In contrast to standard oligonucleotide probes, the RNA polynucleotide probe used here, which targets domain III of the 23S rRNA gene, extends the resolution power in environmental samples by increasing signal intensity. Furthermore, cells hybridized with the polynucleotide probe are not subjected to harsh pretreatments, and their genetic information remains intact. The protocol described here was tested on genus-specifically labeled cells in various samples, including complex fecal samples from different laboratory mouse types that harbor diverse intestinal microbiota. Specifically, as an example for the protocol described here, RNA polynucleotide probes could be used to label Enterococcus cells for subsequent sorting by flow cytometry. To detect and quantify enterococci in fecal samples prior to enrichment, taxon-specific PCR and qPCR detection systems have been developed. The accessibility of the genomes from taxon-specifically sorted cells for subsequent molecular analyses was demonstrated by amplification of functional genes. Copyright © 2016 Elsevier GmbH. All rights reserved.

  11. Tidal flow dynamics and background fluorescence of the Atlantic Intracoastal Waterway in the vicinity of Sullivan’s Island and the Isle of Palms, South Carolina, 2011-12

    USGS Publications Warehouse

    Conrads, Paul; Journey, Celeste A.; Clark, Jimmy M.; Levesque, Victor A.

    2013-01-01

    To effectively plan site-specific studies to understand the connection between wastewater effluent and shellfish beds, data are needed concerning flow dynamics and background fluorescence in the Atlantic Intracoastal Waterway near the effluent outfalls on Sullivan’s Island and the Isle of Palms. Tidal flows were computed by the U.S. Geological Survey for three stations and longitudinal water-quality profiles were collected at high and low tide. Flows for the three U.S. Geological Survey stations, the Atlantic Intracoastal Waterway by the Isle of Palms Marina, the Atlantic Intracoastal Waterway by the Ben M. Sawyer Memorial Bridge at Sullivan’s Island, and Breach Inlet, were computed for the 53-day period from December 4, 2011, to January 26, 2012. The largest flows occurred at Breach Inlet and ranged from -58,600 cubic feet per second (ft3/s) toward the Atlantic Intracoastal Waterway to 63,300 ft3/s toward the Atlantic Ocean. Of the two stations on the Atlantic Intracoastal Waterway, the Sullivan’s Island station had the larger flows and ranged from -6,360 ft3/s to the southwest (toward Charleston Harbor) to 8,930 ft3/s to the northeast. Computed tidal flow at the Isle of Palms station ranged from -3,460 ft3/s toward the southwest to 6,410 ft3/s toward the northeast. The synoptic water-quality study showed that the stations were well mixed vertically and horizontally. All fluorescence measurements (recorded as rhodamine concentration) were below the accuracy of the sensor and the background fluorescence would not likely interfere with a dye-tracer study.

  12. Physiology of spermatozoa at high dilution rates: the influence of seminal plasma.

    PubMed

    Maxwell, W M; Johnson, L A

    1999-12-01

    Extensive dilution of spermatozoa, as occurs during flow-cytometric sperm sorting, can reduce their motility and viability. These effects may be minimized by the use of appropriate dilution and collection media, containing balanced salts, energy sources, egg yolk and some protein. Dilution and flow-cytometric sorting of spermatozoa, which involves the removal of seminal plasma, also destabilizes sperm membranes leading to functional capacitation. This membrane destabilization renders the spermatozoa immediately capable of fertilization in vitro, or in vivo after deposition close to the site of fertilization, but shortens their lifespan, resulting in premature death if the cells are deposited in the female tract distant from the site of fertilization or are held in vitro at standard storage temperatures. This functional capacitation can be reversed in boar spermatozoa by inclusion of seminal plasma in the medium used to collect the cells from the cell sorter and, consequently, reduces their in vitro fertility. It has yet to be determined whether seminal plasma would have similar effects on flow cytometrically sorted spermatozoa of other species, and what its effects might be on the in vivo fertility of flow sorted boar.

  13. Role of receptor occupancy assays by flow cytometry in drug development.

    PubMed

    Stewart, Jennifer J; Green, Cherie L; Jones, Nicholas; Liang, Meina; Xu, Yuanxin; Wilkins, Danice E C; Moulard, Maxime; Czechowska, Kamila; Lanham, David; McCloskey, Thomas W; Ferbas, John; van der Strate, Barry W A; Högerkorp, Carl-Magnus; Wyant, Timothy; Lackey, Alan; Litwin, Virginia

    2016-03-01

    The measurement of the binding of a biotherapeutic to its cellular target, receptor occupancy (RO), is increasingly important in development of biologically-based therapeutic agents. Receptor occupancy (RO) assays by flow cytometry describe the qualitative and/or quantitative assessment of the binding of a therapeutic agent to its cell surface target. Such RO assays can be as simple as measuring the number of cell surface receptors bound by an antireceptor therapeutic agent or can be designed to address more complicated scenarios such as internalization or shedding events once a receptor engages the administered therapeutic agent. Data generated from RO assays can also be used to model whether given doses of an experimental therapeutic agent and their administration schedules lead to predicted levels of receptor occupancy and whether the receptor is modulated (up or down) on cells engaged by the therapeutic agent. There are a variety of approaches that can be used when undertaking RO assays and with the ability to measure distinct subsets in heterogeneous populations, flow cytometry is ideally suited to RO measurements. This article highlights the importance of RO assays on the flow cytometric platform in the development of biotherapeutic agents. © 2016 The Authors Cytometry Part B: Clinical Cytometry Published by Wiley Periodicals, Inc.

  14. Differences in genetic background influence the induction of innate and acquired immune responses in chickens depending on the virulence of the infecting infectious bursal disease virus (IBDV) strain.

    PubMed

    Aricibasi, Merve; Jung, Arne; Heller, E Dan; Rautenschlein, Silke

    2010-05-15

    Previous studies and field observations have suggested that genetic background influences infectious bursal disease virus (IBDV) pathogenesis. However, the influence of the virulence of the infecting IBDV strain and the mechanisms underlying the differences in susceptibility are not known. In the present study IBDV pathogenesis was compared between specific-pathogen-free layer-type (LT) chickens, which are the most susceptible chicken for IBDV and have been used as the model for pathogenesis studies, and broiler-type (BT) chickens, which are known to be less susceptible to clinical infectious bursal disease (IBD). The innate and acquired immune responses were investigated after inoculation of an intermediate (i), virulent (v) or very virulent (vv) strain of IBDV. IBDV pathogenesis was comparable among genetic backgrounds after infection with iIBDV. After infection with vIBDV and vvIBDV, LT birds showed severe clinical disease and mortality, higher bursal lesion scores and IBDV-antigen load relative to BT birds. Circulating cytokine induction varied significantly in both timing and quantity between LT and BT birds and among virus strains (P<0.05). Evaluation of different immune cell populations by flow-cytometric analysis in the bursa of Fabricius provided circumstantial evidence of a stronger local T cell response in BT birds vs. LT birds after infection with the virulent strain. On the other hand, LT birds showed a more significant increase in circulating macrophage-derived immune mediators such as total interferon (IFN) and serum nitrite than BT birds on days 2 and 3 post-vIBDV infection (P<0.05). Stronger stimulation of innate immune reactions especially after vIBDV infection in the early phase may lead to faster and more severe lesion development accompanied by clinical disease and death in LT chickens relative to BT chickens. Interestingly, no significant differences were seen between genetic backgrounds in induction of the IBDV-specific humoral response

  15. Effects of pre-analytical variables on flow cytometric diagnosis of canine lymphoma: A retrospective study (2009-2015).

    PubMed

    Comazzi, S; Cozzi, M; Bernardi, S; Zanella, D R; Aresu, L; Stefanello, D; Marconato, L; Martini, V

    2018-02-01

    Flow cytometry (FC) is increasingly being used for immunophenotyping and staging of canine lymphoma. The aim of this retrospective study was to assess pre-analytical variables that might influence the diagnostic utility of FC of lymph node (LN) fine needle aspirate (FNA) specimens from dogs with lymphoproliferative diseases. The study included 987 cases with LN FNA specimens sent for immunophenotyping that were submitted to a diagnostic laboratory in Italy from 2009 to 2015. Cases were grouped into 'diagnostic' and 'non-diagnostic'. Pre-analytical factors analysed by univariate and multivariate analyses were animal-related factors (breed, age, sex, size), operator-related factors (year, season, shipping method, submitting veterinarian) and sample-related factors (type of sample material, cellular concentration, cytological smears, artefacts). The submitting veterinarian, sample material, sample cellularity and artefacts affected the likelihood of having a diagnostic sample. The availability of specimens from different sites and of cytological smears increased the odds of obtaining a diagnostic result. Major artefacts affecting diagnostic utility included poor cellularity and the presence of dead cells. Flow cytometry on LN FNA samples yielded conclusive results in more than 90% of cases with adequate sample quality and sampling conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Telomere content measurement in human hematopoietic cells: Comparative analysis of qPCR and Flow-FISH techniques.

    PubMed

    Wand, Taylor; Fang, Mike; Chen, Christina; Hardy, Nathan; McCoy, J Philip; Dumitriu, Bogdan; Young, Neal S; Biancotto, Angélique

    2016-10-01

    Abnormal telomere lengths have been linked to cancer and other hematologic disorders. Determination of mean telomere content (MTC) is traditionally performed by Southern blotting and densitometry, giving a mean telomere restriction fragment (TRF) value for the total cell population studied. Here, we compared a quantitative Polymerase Chain Reaction approach (qPCR) and a flow cytometric approach, fluorescence in situ hybridization (Flow-FISH), to evaluate telomere content distribution in total patient peripheral blood mononuclear cells or specific cell populations. Flow-FISH is based on in situ hybridization using a fluorescein-labeled peptide nucleic acid (PNA) (CCCTAA) 3 probe and DNA staining with propidium iodide. We showed that both qPCR and Flow-FISH provide a robust measurement, with Flow-FISH measuring a relative content longer than qPCR at a single cell approach and that TRF2 fluorescence intensity did not correlate with MTC. Both methods showed comparable telomere content reduction with age, and the rate of relative telomere loss was similar. Published 2016 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America. Published 2016 Wiley Periodicals Inc. This article is a US government work and, as such, is in the public domain in the United States of America.

  17. Flow cytometric analysis of cell killing by the jumper ant venom peptide pilosulin 1.

    PubMed

    King, M A; Wu, Q X; Donovan, G R; Baldo, B A

    1998-08-01

    Pilosulin 1 is a synthetic 56-amino acid residue polypeptide that corresponds to the largest allergenic polypeptide found in the venom of the jumper ant Myrmecia pilosula. Initial experiments showed that pilosulin 1 lysed erythrocytes and killed proliferating B cells. Herein, we describe how flow cytometry was used to investigate the cytotoxicity of the peptide for human white blood cells. Cells were labeled with fluorochrome-conjugated antibodies, incubated with the peptide and 7-aminoactinomycin D (7-AAD), and then analyzed. The effects of varying the peptide concentration, serum concentration, incubation time, and incubation temperature were measured, and the cytotoxicity of pilosulin 1 was compared with that of the bee venom peptide melittin. The antibodies and the 7-AAD enabled the identification of cell subpopulations and dead cells, respectively. It was possible, using the appropriate mix of antibodies and four-color analysis, to monitor the killing of three or more cell subpopulations simultaneously. We found that 1) pilosulin 1 killed cells within minutes, with kinetics similar to those of melittin; 2) pilosulin 1 was a slightly more potent cytotoxic agent than melittin; 3) both pilosulin 1 and melittin were more potent against mononuclear leukocytes than against granulocytes; and 4) serum inhibited killing by either peptide.

  18. The use of flow cytometry to examine calcium signalling by TRPV1 in mixed cell populations.

    PubMed

    Assas, Bakri M; Abdulaal, Wesam H; Wakid, Majed H; Zakai, Haytham A; Miyan, J; Pennock, J L

    2017-06-15

    Flow cytometric analysis of calcium mobilisation has been in use for many years in the study of specific receptor engagement or isolated cell:cell communication. However, calcium mobilisation/signaling is key to many cell functions including apoptosis, mobility and immune responses. Here we combine multiplex surface staining of whole spleen with Indo-1 AM to visualise calcium mobilisation and examine calcium signaling in a mixed immune cell culture over time. We demonstrate responses to a TRPV1 agonist in distinct cell subtypes without the need for cell separation. Multi parameter staining alongside Indo-1 AM to demonstrate calcium mobilization allows the study of real time calcium signaling in a complex environment. Copyright © 2017. Published by Elsevier Inc.

  19. SPICE: exploration and analysis of post-cytometric complex multivariate datasets.

    PubMed

    Roederer, Mario; Nozzi, Joshua L; Nason, Martha C

    2011-02-01

    Polychromatic flow cytometry results in complex, multivariate datasets. To date, tools for the aggregate analysis of these datasets across multiple specimens grouped by different categorical variables, such as demographic information, have not been optimized. Often, the exploration of such datasets is accomplished by visualization of patterns with pie charts or bar charts, without easy access to statistical comparisons of measurements that comprise multiple components. Here we report on algorithms and a graphical interface we developed for these purposes. In particular, we discuss thresholding necessary for accurate representation of data in pie charts, the implications for display and comparison of normalized versus unnormalized data, and the effects of averaging when samples with significant background noise are present. Finally, we define a statistic for the nonparametric comparison of complex distributions to test for difference between groups of samples based on multi-component measurements. While originally developed to support the analysis of T cell functional profiles, these techniques are amenable to a broad range of datatypes. Published 2011 Wiley-Liss, Inc.

  20. Flow Cytometric Measurement of Cellular Ionized Calcium Concentration

    DTIC Science & Technology

    1988-01-01

    AD-A207 011 ORT DOCUMENTATION PAGE lb. RESTRICTIVE MARKINGS i. .a. SECRIrY CL.AS.FICA𔃻iON AUTHORITY -- 3 DISTRIBUTION/AVAILA3BLIrY OF REPORT...Cytometry 8: 396-404 K.E.; Ledbetter, iA.; Rabinovitch, P.S.; Morishi- (1987). -ta, Y.; Hellstrom, I.; Hansen, J.A.: Induction of 14 Cobbold , P.H.; Rink

  1. Systematic Methodological Evaluation of a Multiplex Bead-Based Flow Cytometry Assay for Detection of Extracellular Vesicle Surface Signatures

    PubMed Central

    Wiklander, Oscar P. B.; Bostancioglu, R. Beklem; Welsh, Joshua A.; Zickler, Antje M.; Murke, Florian; Corso, Giulia; Felldin, Ulrika; Hagey, Daniel W.; Evertsson, Björn; Liang, Xiu-Ming; Gustafsson, Manuela O.; Mohammad, Dara K.; Wiek, Constanze; Hanenberg, Helmut; Bremer, Michel; Gupta, Dhanu; Björnstedt, Mikael; Giebel, Bernd; Nordin, Joel Z.; Jones, Jennifer C.; EL Andaloussi, Samir; Görgens, André

    2018-01-01

    Extracellular vesicles (EVs) can be harvested from cell culture supernatants and from all body fluids. EVs can be conceptually classified based on their size and biogenesis as exosomes and microvesicles. Nowadays, it is however commonly accepted in the field that there is a much higher degree of heterogeneity within these two subgroups than previously thought. For instance, the surface marker profile of EVs is likely dependent on the cell source, the cell’s activation status, and multiple other parameters. Within recent years, several new methods and assays to study EV heterogeneity in terms of surface markers have been described; most of them are being based on flow cytometry. Unfortunately, such methods generally require dedicated instrumentation, are time-consuming and demand extensive operator expertise for sample preparation, acquisition, and data analysis. In this study, we have systematically evaluated and explored the use of a multiplex bead-based flow cytometric assay which is compatible with most standard flow cytometers and facilitates a robust semi-quantitative detection of 37 different potential EV surface markers in one sample simultaneously. First, assay variability, sample stability over time, and dynamic range were assessed together with the limitations of this assay in terms of EV input quantity required for detection of differently abundant surface markers. Next, the potential effects of EV origin, sample preparation, and quality of the EV sample on the assay were evaluated. The findings indicate that this multiplex bead-based assay is generally suitable to detect, quantify, and compare EV surface signatures in various sample types, including unprocessed cell culture supernatants, cell culture-derived EVs isolated by different methods, and biological fluids. Furthermore, the use and limitations of this assay to assess heterogeneities in EV surface signatures was explored by combining different sets of detection antibodies in EV samples derived

  2. Systematic Methodological Evaluation of a Multiplex Bead-Based Flow Cytometry Assay for Detection of Extracellular Vesicle Surface Signatures.

    PubMed

    Wiklander, Oscar P B; Bostancioglu, R Beklem; Welsh, Joshua A; Zickler, Antje M; Murke, Florian; Corso, Giulia; Felldin, Ulrika; Hagey, Daniel W; Evertsson, Björn; Liang, Xiu-Ming; Gustafsson, Manuela O; Mohammad, Dara K; Wiek, Constanze; Hanenberg, Helmut; Bremer, Michel; Gupta, Dhanu; Björnstedt, Mikael; Giebel, Bernd; Nordin, Joel Z; Jones, Jennifer C; El Andaloussi, Samir; Görgens, André

    2018-01-01

    Extracellular vesicles (EVs) can be harvested from cell culture supernatants and from all body fluids. EVs can be conceptually classified based on their size and biogenesis as exosomes and microvesicles. Nowadays, it is however commonly accepted in the field that there is a much higher degree of heterogeneity within these two subgroups than previously thought. For instance, the surface marker profile of EVs is likely dependent on the cell source, the cell's activation status, and multiple other parameters. Within recent years, several new methods and assays to study EV heterogeneity in terms of surface markers have been described; most of them are being based on flow cytometry. Unfortunately, such methods generally require dedicated instrumentation, are time-consuming and demand extensive operator expertise for sample preparation, acquisition, and data analysis. In this study, we have systematically evaluated and explored the use of a multiplex bead-based flow cytometric assay which is compatible with most standard flow cytometers and facilitates a robust semi-quantitative detection of 37 different potential EV surface markers in one sample simultaneously. First, assay variability, sample stability over time, and dynamic range were assessed together with the limitations of this assay in terms of EV input quantity required for detection of differently abundant surface markers. Next, the potential effects of EV origin, sample preparation, and quality of the EV sample on the assay were evaluated. The findings indicate that this multiplex bead-based assay is generally suitable to detect, quantify, and compare EV surface signatures in various sample types, including unprocessed cell culture supernatants, cell culture-derived EVs isolated by different methods, and biological fluids. Furthermore, the use and limitations of this assay to assess heterogeneities in EV surface signatures was explored by combining different sets of detection antibodies in EV samples derived

  3. Self-organized criticality in a two-dimensional cellular automaton model of a magnetic flux tube with background flow

    NASA Astrophysics Data System (ADS)

    Dănilă, B.; Harko, T.; Mocanu, G.

    2015-11-01

    We investigate the transition to self-organized criticality in a two-dimensional model of a flux tube with a background flow. The magnetic induction equation, represented by a partial differential equation with a stochastic source term, is discretized and implemented on a two-dimensional cellular automaton. The energy released by the automaton during one relaxation event is the magnetic energy. As a result of the simulations, we obtain the time evolution of the energy release, of the system control parameter, of the event lifetime distribution and of the event size distribution, respectively, and we establish that a self-organized critical state is indeed reached by the system. Moreover, energetic initial impulses in the magnetohydrodynamic flow can lead to one-dimensional signatures in the magnetic two-dimensional system, once the self-organized critical regime is established. The applications of the model for the study of gamma-ray bursts (GRBs) is briefly considered, and it is shown that some astrophysical parameters of the bursts, like the light curves, the maximum released energy and the number of peaks in the light curve can be reproduced and explained, at least on a qualitative level, by working in a framework in which the systems settles in a self-organized critical state via magnetic reconnection processes in the magnetized GRB fireball.

  4. Collection, Storage, and Preparation of Human Blood Cells

    PubMed Central

    Dagur, Pradeep K.; McCoy, J. Philip

    2015-01-01

    Human peripheral blood is often studied by flow cytometry in both the research and clinical laboratories. The methods for collection, storage, and preparation of peripheral blood will vary depending on the cell lineage to be examined as well as the type of assay to be performed. This unit presents protocols for collection of blood, separation of leukocytes from whole blood by lysis of erythrocytes, isolating mononuclear cells by density gradient separation, and assorted non-flow sorting methods, such as magnetic bead separations, for enriching specific cell populations, including monocytes, T lymphocytes, B lymphocytes, neutrophils,, , and platelets prior to flow cytometric analysis. A protocol is also offered for cryopreservation of cells since clinical research often involves retrospective flow cytometric analysis of samples stored over a period of months or years. PMID:26132177

  5. Background Music in Educational Games: Motivational Appeal and Cognitive Impact

    ERIC Educational Resources Information Center

    Linek, Stephanie B.; Marte, Birgit; Albert, Dietrich

    2011-01-01

    Most game-designers likely stick to the assumption that background music is a design feature for fostering fun and game play. From a psychological point of view, these (intuitive) aspects act upon the intrinsic motivation and the flow experience of players. However, from a pure cognitive perspective on instructional design, background music could…

  6. Flow cytometry for receptor analysis from ex-vivo brain tissue in adult rat.

    PubMed

    Benoit, A; Guillamin, M; Aitken, P; Smith, P F; Philoxene, B; Sola, B; Poulain, L; Coquerel, A; Besnard, S

    2018-07-01

    Flow cytometry allows single-cell analysis of peripheral biological samples and is useful in many fields of research and clinical applications, mainly in hematology, immunology, and oncology. In the neurosciences, the flow cytometry separation method was first applied to stem cell extraction from healthy or cerebral tumour tissue and was more recently tested in order to phenotype brain cells, hippocampal neurogenesis, and to detect prion proteins. However, it remains sparsely applied in quantifying membrane receptors in relation to synaptic plasticity. We aimed to optimize a flow cytometric procedure for receptor quantification in neurons and non-neurons. A neural dissociation process, myelin separation, fixation, and membrane permeability procedures were optimized to maximize cell survival and analysis in hippocampal tissue obtained from adult rodents. We then aimed to quantify membrane muscarinic acetylcholine receptors (mAChRs) in rats with and without bilateral vestibular loss (BVL). mAChR's were quantified for neuronal and non-neuronal cells in the hippocampus and striatum following BVL. At day 30 but not at day 7 following BVL, there was a significant increase (P ≤ 0.05) in the percentage of neurons expressing M 2/4 mAChRs in both the hippocampus and the striatum. Here, we showed that flow cytometry appears to be a reliable method of membrane receptor quantification in ex-vivo brain tissue. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Flow cytometric analysis of red-eared slider turtles (Trachemys scripta) from Tar Creek Superfund Site.

    PubMed

    Hays, Kimberly A; McBee, Karen

    2007-05-01

    Tar Creek Superfund Site (TCSFS) was heavily mined from the 1890s to 1970 and currently is contaminated with lead, zinc, and cadmium. Flow cytometry (FCM) was used to measure variation in nuclear DNA content of red blood cells collected from Trachemys scripta living within TCSFS and reference sites, Lake Carl Blackwell (LCB) and Sequoyah National Wildlife Refuge (SNWR). We also used atomic absorption spectrometry to measure Pb in blood and carapace and Cd in blood samples of turtles from TCSFS and SNWR. Mean coefficients of variation around the G(1) peak ranged from 5.33 to 5.48 and showed no significant difference between contaminated and reference populations; however, there was a significantly higher frequency of aneuploidy at TCSFS when compared with both reference populations. Blood Pb levels were not significantly different between TCSFS and SNWR populations. Pb levels in carapace samples did not differ significantly between sites; however, Pb levels were higher in carapace than blood for both populations. Blood Cd was significantly higher in animals at TCSFS than SNWR.

  8. Flow cytometric characterization of phenotype, DNA indices and p53 gene expression in 55 cases of acute leukemia.

    PubMed

    Powari, Manish; Varma, Neelam; Varma, Subhash; Marwaha, Ram Kumar; Sandhu, Harpreet; Ganguly, Nirmal Kumar

    2002-06-01

    To characterize the phenotype of acute leukemia cases using flow cytometry, to detect mixed lineage cases and to use DNA index determination, including S-phase fraction (SPF) and p53 detection, to find if there was any correlation of SPF and p53 expression with outcome. Fifty-five cases of acute leukemia were enrolled in this study. A complete hemogram and routine bone marrow examination, including cytochemistry, was done. Mycloperoxidase-negative cases were evaluated on a flow cytometer using monoclonal antibodies. DNA indices were determined by flow cytometry in all cases, and p53 was detected immunohistochemically using the alkaline phosphatase/antialkaline phosphatase technique. Acute myeloblastic leukemia (AML) was diagnosed in 32 cases; acute lymphoblastic leukemia (ALL) was diagnosed in 18 (14 B lineage and 4 T line age). Four cases showed mixed lineage leukemia, and undifferentiated acute leukemia was diagnosed in one case. The mean/range of SPF for these groups were 3.76/0.33-6.91, 6.25/0.15-21.4, 2.89/0.35-10.64, 2.60/0.72-6.94 and 7.34, respectively. Aneuploidy was detected in two cases of B-lineage ALL and tetraploidy in a case of AML-M7, while all others were diploid p53. Was detected in 6 of 55 cases (10.90%). Follow-up was available for 24 patients. Five patients relapsed, and four had B-cell type ALL and were diploid and expressed no p53 gene. SPF% did not show any correlation with outcome. These data suggest that within acute leukemia subtypes, there is a wide variation in SPF. SPF does not seem to correlate with outcome. Immunophenotyping is essential to determine the lineage in myeloperoxidase-negative cases. It is perhaps the only way to diagnose mixed lineage leukemia and aberrant expression of markers presently. The p53 gene was detected less frequently. However, more studies are required from different centers with longer follow-up to evaluate prognostic significance.

  9. The role of RhD agglutination for the detection of weak D red cells by anti-D flow cytometry.

    PubMed

    Grey, D E; Davies, J I; Connolly, M; Fong, E A; Erber, W N

    2005-04-01

    Anti-D flow cytometry is an accurate method for quantifying feto-maternal haemorrhage (FMH). However, weak D red cells with <1000 RhD sites are not detectable using this methodology but are immunogenic. As quantitation of RhD sites is not practical, an alternative approach is required to identify those weak D fetal red cells where anti-D flow cytometry is inappropriate. We describe a simple algorithm based on RhD agglutination and flow cytometry peak separation. All weak D (n = 34) gave weak agglutination with RUM-1 on immediate spin (grading flow cytometry. In the second subgroup, agglutination was strong (grading 4) and the red cells were detectable by anti-D flow cytometry. The accuracy of the quantitation was dependent on adequate separation of the weak D and RhD-negative peaks as in seven of 11 samples <1.11% of an expected 2% red cells were detectable. Monitoring RhD agglutination and flow cytometric peak separation are pivotal if anti-D flow cytometry is to be maintained as the primary technique for FMH quantitation in the routine laboratory.

  10. Development of a novel flow cytometric approach to evaluate fish sperm chromatin using fixed samples

    USGS Publications Warehouse

    Jenkins, Jill A.

    2013-01-01

    The integrity of the paternal DNA is essential for the accurate transmission of genetic information, yet fertilization is not inhibited by chromatin breakage. Some methods are available for the sensitive detection of DNA damage and can be applied in studies of environmental toxicology, carcinogenesis, aging, and assisted reproduction techniques in both clinical and experimental settings. Because semen samples obtained from remote locations undergo chromatin damage prior to laboratory assessment, the present study was undertaken to evaluate treatments for effective chromatin staining in the development of a DNA fragmentation assay using fixed milt from yellow perch (Perca flavescens). Similar to the sperm chromatin structure assay (SCSA), susceptibility of nuclear DNA to acid-induced denaturation was measured by flow cytometry (FCM). Use of 10% buffered formalin for milt fixation allowed easier peak discrimination than 4% paraformaldehyde. The effects of time and temperature of incubation in 0.08 N HCl were evaluated in order to determine the ideal conditions for promoting DNA decondensation and making strand breaks more available for staining and detection by FCM. The best results were obtained with incubation at 37°C for 1 minute, followed by cold propidium iodide staining for 30 minutes.

  11. Functional characterization of neotropical snakes peripheral blood leukocytes subsets: Linking flow cytometry cell features, microscopy images and serum corticosterone levels.

    PubMed

    de Carvalho, Marcelo Pires Nogueira; Queiroz-Hazarbassanov, Nicolle Gilda Teixeira; de Oliveira Massoco, Cristina; Sant'Anna, Sávio Stefanini; Lourenço, Mariana Mathias; Levin, Gabriel; Sogayar, Mari Cleide; Grego, Kathleen Fernandes; Catão-Dias, José Luiz

    2017-09-01

    Reptiles are the unique ectothermic amniotes, providing the key link between ectothermic anamniotes fish and amphibians, and endothermic birds and mammals; becoming an important group to study with the aim of providing significant knowledge into the evolutionary history of vertebrate immunity. Classification systems for reptiles' leukocytes have been described by their appearance rather than function, being still inconsistent. With the advent of modern techniques and the establishment of analytical protocols for snakes' blood by flow cytometry, we bring a qualitative and quantitative assessment of innate activities presented by snakes' peripheral blood leukocytes, thereby linking flow cytometric features with fluorescent and light microscopy images. Moreover, since corticosterone is an important immunomodulator in reptiles, hormone levels of all blood samples were measured. We provide novel and additional information which should contribute to better understanding of the development of the immune system of reptiles and vertebrates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders part 4 - assay validation and quality assurance.

    PubMed

    Oldaker, Teri; Whitby, Liam; Saber, Maryam; Holden, Jeannine; Wallace, Paul K; Litwin, Virginia

    2018-01-01

    Over the past six years, a diverse group of stakeholders have put forth recommendations regarding the analytical validation of flow cytometric methods and described in detail the differences between cell-based and traditional soluble analyte assay validations. This manuscript is based on these general recommendations as well as the published experience of experts in the area of PNH testing. The goal is to provide practical assay-specific guidelines for the validation of high-sensitivity flow cytometric PNH assays. Examples of the reports and validation data described herein are provided in Supporting Information. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  13. IgA and IgG1 reactivities assessed by flow cytometry mirror clinical aspects of infants with ocular congenital toxoplasmosis.

    PubMed

    de Jesus, Laura Néspoli Nassar Pansini; Tonini, Aline de Castro Zacche; Barros, Geisa Baptista; Coelho-dos-Reis, Jordana Grazziela A; Béla, Samantha Ribeiro; Antonelli, Lis Ribeiro do Valle; Machado, Anderson Silva; Carneiro, Ana Carolina Aguiar Vasconcelos; Andrade, Gláucia Manzan Queiroz; Vasconcelos-Santos, Daniel Vitor; Januário, José Nélio; Teixeira-Carvalho, Andréa; Vitor, Ricardo Wagner Almeida; Ferro, Eloísa A V; Mineo, José Roberto; Bahia-Oliveira, Lilian Maria Garcia; Martins-Filho, Olindo Assis; Lemos, Elenice Moreira

    2016-01-01

    This study intended to apply the flow cytometric analysis of IgA and IgG reactivity and intracytoplasmic cytokine analysis to understand and decode the clinical aspects of infants with ocular congenital toxoplasmosis. The Toxoplasma gondii-infected infants (TOXO) were subdivided according to their clinical aspects based on the absence (NRL), presence of active (ARL), active/cicatricial (ACRL) or cicatricial retinochoroidal lesions (CRL) and compared to non-infected controls (NI). The reactivity of anti-T. gondii IgG subclasses resembles the clinical aspects of ocular lesions. IgG and IgG1 discriminate infants with cicatricial lesions (ACRL and CRL) from both ARL and NLR. IgG2 and IgG3 are particularly higher in ACRL and CRL as compared to NLR. No differences were observed when IgG4 reactivity was evaluated. Thus, the results indicated that the reactivity patterns of IgA, IgG and IgG subclasses are able to discriminate ARL, ACRL and CRL from NLR or NI. IgA and IgG subclasses are relevant serological biomarkers with diagnostic and prognostic applicability, respectively. Moreover, IgA and IgG1 were closely related to cytokine production by innate/adaptive immunity cells. IgA reactivity was directly associated to TNF-α-derived from neutrophils, monocytes and CD8(+) T-cells, while IgG1 was inversely correlated with IFN-γ-producing CD4(+) and CD8(+) T-cells but positively correlated with IL-10(+) B-cells. These findings provide insights on the relationship between the cytokine production by innate/adaptive immunity and the antibody pattern of infants with ocular congenital toxoplasmosis. In addition, the present study supports the use of flow cytometric serology as a potential tool for the diagnosis and monitoring of ocular lesions in T. gondii-infected infants in the clinical setting. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Modification of the background flow by roll vortices

    NASA Technical Reports Server (NTRS)

    Shirer, Hampton N.; Haack, Tracy

    1990-01-01

    Use of observed wind profiles, such as those obtained from ascent or descent aircraft soundings, for the identification of the expected roll modes is hindered by the fact that these modes are able to modify the wind profiles. When such modified wind profiles are utilized to estimate the critical values of the dynamic and thermodynamic forcing rates, large errors in the preferred orientation angles and aspect ratios of the rolls may result. Nonlinear analysis of a 14 coefficient spectral model of roll circulations shows that the primary modification of the background wind is the addition of a linear component. When the linear profile having the correct amount of shear is subtracted from the observed cross-roll winds, then the pre-roll wind profile can be estimated. A preliminary test of this hypothesis is given for a case in which cloud streets were observed during FIRE.

  15. Absolute counting of neutrophils in whole blood using flow cytometry.

    PubMed

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens. © 2014 International Society for Advancement of Cytometry.

  16. Interaction study between synthetic glycoconjugate ligands and endocytic receptors using flow cytometry.

    PubMed

    Yura, Hirofumi; Ishihara, Masayuki; Kanatani, Yasuhiro; Takase, Bonpei; Hattori, Hidemi; Suzuki, Shinya; Kawakami, Mitsuyuki; Matsui, Takemi

    2006-04-01

    Flow cytometric analysis of synthetic galactosyl polymers, asialofetuin and LDL derivatives labeled with FITC (Fluorescein Isothiocyanate) was carried out to determine the phenotypes of endocytic receptors, such as asialoglycoprotein (ASPG) and the LDL receptor, on various types of cells. When FITC-labeled galactosyl polystyrene (GalCPS), being a synthetic ligand of ASPG, was applied to rat hepatocytes and human cancer cells (Hep G2 and Chang Liver), surface fluorescence intensities varied according to receptor expression on the cells. The fluorescence intensity originates from the calcium-dependent binding of the FITC-labeled GalCPS. Although unaltered by pre-treatment with glucosyl polystyrene (GluCPS), fetuin and LDL, the fluorescence intensity was suppressed by pre-treatment with (non-labeled) GalCPS and asialofetuin. Flow cytometry allowed us to demonstrate that the calcium-dependent binding of FITC-labeled LDL (prepared from rabbits) upon the addition of 17alpha-ethinyl estradiol enhances LDL receptor expression, and the expression is suppressed upon the addition of a monoclonal antibody to the LDL receptor. The binding efficiency based on the combination of FITC-labeled ligands suggests a possible application for the classification of cell types and conditions corresponding to endocytic receptor expression without the need for immuno-active antibodies or radiolabeled substances. Furthermore, the synthetic glycoconjugate (GalCPS) is shown to be a sensitive and useful marker for classification based on cell phenotype using flow cytometry.

  17. Background-Oriented Schlieren (BOS) for Scramjet Inlet-isolator Investigation

    NASA Astrophysics Data System (ADS)

    Che Idris, Azam; Rashdan Saad, Mohd; Hing Lo, Kin; Kontis, Konstantinos

    2018-05-01

    Background-oriented Schlieren (BOS) technique is a recently invented non-intrusive flow diagnostic method which has yet to be fully explored in its capabilities. In this paper, BOS technique has been applied for investigating the general flow field characteristics inside a generic scramjet inlet-isolator with Mach 5 flow. The difficulty in finding the delicate balance between measurement sensitivity and measurement area image focusing has been demonstrated. The differences between direct cross-correlation (DCC) and Fast Fourier Transform (FFT) raw data processing algorithm have also been demonstrated. As an exploratory study of BOS capability, this paper found that BOS is simple yet robust enough to be used to visualize complex flow in a scramjet inlet in hypersonic flow. However, in this case its quantitative data can be strongly affected by 3-dimensionality thus obscuring the density value with significant errors.

  18. Preserving Flow Variability in Watershed Model Calibrations

    EPA Science Inventory

    Background/Question/Methods Although watershed modeling flow calibration techniques often emphasize a specific flow mode, ecological conditions that depend on flow-ecology relationships often emphasize a range of flow conditions. We used informal likelihood methods to investig...

  19. Flow-cytometric enrichment of Pacific bluefin tuna type A spermatogonia based on light-scattering properties.

    PubMed

    Ichida, Kensuke; Kise, Kazuyoshi; Morita, Tetsuro; Yazawa, Ryosuke; Takeuchi, Yutaka; Yoshizaki, Goro

    2017-10-01

    We previously established surrogate broodstock in which the donor germ cells transplanted into the peritoneal cavities of xenogeneic recipients were capable of developing into functional eggs and sperm in teleost fish. In this transplantation system, only the undifferentiated germ cells such as type A spermatogonia (ASG) or a portion of the ASG population were capable of being incorporated into the genital ridges of the recipients and undergo gametogenesis. Therefore, the use of enriched ASGs can be expected to achieve efficient donor-cell incorporation. Here, we established a method of isolation and enrichment of the ASG of Pacific bluefin tuna using flow cytometry. Whole testicular cell suspensions were fractionated by forward and side scatter properties, following which ASGs were enriched in a fraction in which the forward scatter signal was relatively high and side scatter signal was relatively low. The diameter of sorted cells using the fraction was identical to the size of ASGs observed in histological analysis, and these cells also expressed the vasa gene. In addition, we succeeded in applying this method to several maturation stages of Pacific bluefin tuna. Since this method was based on light-scattering characteristics of ASGs, it can potentially be applied to various teleosts. We expect that this method can contribute to the production of seeds of Pacific bluefin tuna using surrogate broodstock. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. FLOCK cluster analysis of mast cell event clustering by high-sensitivity flow cytometry predicts systemic mastocytosis.

    PubMed

    Dorfman, David M; LaPlante, Charlotte D; Pozdnyakova, Olga; Li, Betty

    2015-11-01

    In our high-sensitivity flow cytometric approach for systemic mastocytosis (SM), we identified mast cell event clustering as a new diagnostic criterion for the disease. To objectively characterize mast cell gated event distributions, we performed cluster analysis using FLOCK, a computational approach to identify cell subsets in multidimensional flow cytometry data in an unbiased, automated fashion. FLOCK identified discrete mast cell populations in most cases of SM (56/75 [75%]) but only a minority of non-SM cases (17/124 [14%]). FLOCK-identified mast cell populations accounted for 2.46% of total cells on average in SM cases and 0.09% of total cells on average in non-SM cases (P < .0001) and were predictive of SM, with a sensitivity of 75%, a specificity of 86%, a positive predictive value of 76%, and a negative predictive value of 85%. FLOCK analysis provides useful diagnostic information for evaluating patients with suspected SM, and may be useful for the analysis of other hematopoietic neoplasms. Copyright© by the American Society for Clinical Pathology.

  1. In vitro interactions between splenocytes and dansylamide dye-embedded nanoparticles detected by flow cytometry

    PubMed Central

    Nyland, Jennifer F.; Bai, Jennifer J. K.; Katz, Howard E.; Silbergeld, Ellen K.

    2009-01-01

    Engineered nanoparticles (NPs) possess a range of biological activity. In vitro methods for assessing toxicity and efficacy would be enhanced by simultaneous quantitative information on the behavior of NPs in culture systems and signals of cell response. We have developed a method for visualizing NPs within cells using standard flow cytometric techniques and uniquely designed spherical siloxane NPs with an embedded (covalently bound) dansylamide dye. This method allowed NP visualization without obscuring detection of relevant biomarkers of cell subtype, activation state, and other events relevant to assessing bioactivity. We determined that NPs penetrated cells and induced a range of biological signals consistent with activation and costimulation. These results indicate that NPs may affect cell function at concentrations below those inducing cytotoxicity or apoptosis and demonstrate a novel method to image both localization of NPs and cell-level effects. PMID:19523425

  2. Flow analysis of individual blood extracellular vesicles in acute coronary syndrome.

    PubMed

    Vagida, Murad; Arakelyan, Anush; Lebedeva, Anna; Grivel, Jean-Charles; Shpektor, Alexander; Vasilieva, Elena; Margolis, Leonid

    2017-03-01

    A diverse population of small extracellular vesicles (EVs) that are released by various cells has been characterized predominantly in bulk, a procedure whereby the individual characteristics of EVs are lost. Here, we used a new nanotechnology-based flow cytometric analysis to characterize the antigenic composition of individual EVs in patients with acute coronary syndrome (ACS). Plasma EVs were captured with 15-nm magnetic nanoparticles coupled to antibodies against CD31 (predominantly an endothelial marker), CD41a (a marker for platelets), and CD63 or MHC class I (common EV markers). The total amounts of EVs were higher in the ACS patients than in the controls, predominantly due to the contribution of patients with acute myocardial infarction. For all captured fractions, the differences in the EV amounts were restricted to CD41a + EVs. The increase in the numbers of EVs in the ACS patients, predominantly of platelet origin, probably reflects platelet activation and may indicate disease progression.

  3. Comparison of quantitative flow cytometric data provided by panels with lower and increased color number

    NASA Astrophysics Data System (ADS)

    Bocsi, József; Mittag, Anja; Pierzchalski, Arkadiusz; Baumgartner, Adolf; Dähnert, Ingo; Tárnok, Attila

    2012-03-01

    To date the flow cytometry (FCM) industry is booming with new generations of commercial clinical instruments. Long-term clinical studies have the dilemma that moving to new instruments being capable of more complex cell-analysis makes it difficult to compare new data with those obtained on older instruments with less complex analysis panels. Since 15 years we conduct follow-up studies on children with congenital heart diseases. In this period we moved from 2- to 3- and now to 10-color FCM immunophenotyping panels. Questions arise how to compare and transfer data from lower to higher level of complexity. Two comparable antibody panels for leukocyte immunophenotyping (12-tube 2-colors, and 9-tube 4-colors) were measured on a BD FACScalibur FCM (calibration: Spherotech beads) in 19 blood samples from children with congenital heart disease. This increase of colors was accompanied by moving antibodies that were in the 2-color panel either FITC or PE labeled to red dyes such as PerCP or APC. Algorithms were developed for bridging data for quantitative characterization of antigen expression (mean fluorescence intensity) and frequency of different cell subpopulations in combination with rainbow bead standard data. This approach worked for the most relevant antibodies (CD3, CD4, CD8 etc.) well, but rendered substantial uncertainty for activation markers (CD69 etc.). Our techniques are particularly well suited to the analysis in long-term studies and have the potential to compare older and recent results in a standardized way.

  4. Malathion-induced granulosa cell apoptosis in caprine antral follicles: an ultrastructural and flow cytometric analysis.

    PubMed

    Bhardwaj, Jitender K; Saraf, Priyanka

    2014-12-01

    Organophosphate pesticides (OPs) like malathion interfere with normal ovarian function resulting in an increased incidence of atresia and granulosa cell apoptosis that plays a consequential role in the loss of ovarian follicles or follicular atresia. The aim of present study was to assess malathion-induced (100 nM) reproductive stress, ultrastructural damage and changes in apoptosis frequency in ovarian granulosa cells of antral follicles. Transmission electron microscopy (TEM) was employed for ultrastructural characterization, oxidative stress was evaluated using thiobarbituric acid reactive substances (TBARS) assay to measure lipid peroxidation, and apoptosis was quantified via flow cytometry. By TEM, apoptosis was identified by the presence of an indented nuclear membrane with blebbing, pyknotic crescent-shaped fragmented nuclei, increased vacuolization, degenerating mitochondria, and lipid droplets. The results indicate a significant increase in malondialdehyde (MDA) level (nmols/g wet tissue) at a 100 nM dose of malathion i.e. 7.57±0.033*, 8.53±0.12*, and 12.87±0.78** at 4, 6, or 8 h, respectively, as compared with controls (6.07±0.033, p<0.01*, p<0.05**) showing a positive correlation between malathion-induced lipid peroxidation and percentage of granulosa cell apoptosis (r=1; p<0.01). The parallel use of these three methods enabled us to determine the role of malathion in inducing apoptosis as a consequence of cytogenetic damage and oxidative stress generated in granulosa cells of antral follicles.

  5. Flow Cytometric Analysis of Mononuclear Phagocytes in Nondiseased Human Lung and Lung-Draining Lymph Nodes.

    PubMed

    Desch, A Nicole; Gibbings, Sophie L; Goyal, Rajni; Kolde, Raivo; Bednarek, Joe; Bruno, Tullia; Slansky, Jill E; Jacobelli, Jordan; Mason, Robert; Ito, Yoko; Messier, Elise; Randolph, Gwendalyn J; Prabagar, Miglena; Atif, Shaikh M; Segura, Elodie; Xavier, Ramnik J; Bratton, Donna L; Janssen, William J; Henson, Peter M; Jakubzick, Claudia V

    2016-03-15

    The pulmonary mononuclear phagocyte system is a critical host defense mechanism composed of macrophages, monocytes, monocyte-derived cells, and dendritic cells. However, our current characterization of these cells is limited because it is derived largely from animal studies and analysis of human mononuclear phagocytes from blood and small tissue resections around tumors. Phenotypic and morphologic characterization of mononuclear phagocytes that potentially access inhaled antigens in human lungs. We acquired and analyzed pulmonary mononuclear phagocytes from fully intact nondiseased human lungs (including the major blood vessels and draining lymph nodes) obtained en bloc from 72 individual donors. Differential labeling of hematopoietic cells via intrabronchial and intravenous administration of antibodies within the same lobe was used to identify extravascular tissue-resident mononuclear phagocytes and exclude cells within the vascular lumen. Multiparameter flow cytometry was used to identify mononuclear phagocyte populations among cells labeled by each route of antibody delivery. We performed a phenotypic analysis of pulmonary mononuclear phagocytes isolated from whole nondiseased human lungs and lung-draining lymph nodes. Five pulmonary mononuclear phagocytes were observed, including macrophages, monocyte-derived cells, and dendritic cells that were phenotypically distinct from cell populations found in blood. Different mononuclear phagocytes, particularly dendritic cells, were labeled by intravascular and intrabronchial antibody delivery, countering the notion that tissue and blood mononuclear phagocytes are equivalent systems. Phenotypic descriptions of the mononuclear phagocytes in nondiseased lungs provide a precedent for comparative studies in diseased lungs and potential targets for therapeutics.

  6. A Study of the Effects of High Power Pulsed 2450 MHz Microwaves, ELF modulated Microwaves, and ELF Fields on Human Lymphocytes and Selected Cell Lines

    DTIC Science & Technology

    1993-01-27

    Considerable effect was expended in investigating shifts in intercellular calcium of one particular cell line, Jurket, using flow cytometry methods. No...culture. The following analysis were used to characterize the immortalized cell lines: flow cytometry , electron microscopy, two-dimensional protein gel...further characterized by flow cytometry , electron microscopy, two dimensional protein electrophoresis and nuclear run-off assay. Flow cytometric analysis of

  7. Method and apparatus for acoustically monitoring the flow of suspended solid particulate matter. [Patent application; monitoring char flow in coal gasifier

    DOEpatents

    Roach, P.D.; Raptis, A.C.

    1980-11-24

    A method and apparatus for monitoring char flow in a coal gasifier system includes flow monitor circuits which measure acoustic attenuation caused by the presence of char in a char line and provides a char flow/no flow indication and an indication of relative char density. The flow monitor circuits compute the ratio of signals in two frequency bands, a first frequency band representative of background noise, and a second higher frequency band in which background noise is attenuated by the presence of char. Since the second frequency band contains higher frequencies, the ratio can be used to provide a flow/no flow indication. The second band can also be selected so that attenuation is monotonically related to particle concentration, providing a quantitative measure of char concentration.

  8. Striations and preferred eddy tracks triggered by topographic steering of the background flow in the eastern South Pacific

    NASA Astrophysics Data System (ADS)

    Belmadani, Ali; Concha, Emilio; Donoso, David; Chaigneau, Alexis; Colas, François; Maximenko, Nikolai; Di Lorenzo, Emanuele

    2017-04-01

    In recent years, persistent quasi-zonal jets or striations have been ubiquitously detected in the world ocean using satellite and in situ data as well as numerical models. This study aims at determining the role of mesoscale eddies in the generation and persistence of striations off Chile in the eastern South Pacific. A 50 year climatological integration of an eddy-resolving numerical ocean model is used to assess the long-term persistence of striations. Automated eddy tracking algorithms are applied to the model outputs and altimetry data. Results reveal that striations coincide with both polarized eddy tracks and the offshore formation of new eddies in the subtropical front and coastal transition zone, without any significant decay over time that discards random eddies as a primary driver of the striations. Localized patches of vortex stretching and relative vorticity advection, alternating meridionally near the eastern edge of the subtropical front, are associated with topographic steering of the background flow in the presence of steep topography, and with baroclinically and barotropically unstable meridional flow. These sinks and sources of vorticity are suggested to generate the banded structure further west, consistently with a β-plume mechanism. On the other hand, zonal/meridional eddy advection of relative vorticity and the associated Reynolds stress covariance are consistent with eddy deformation over rough topography and participate to sustain the striations in the far field. Shear instability of mean striations is proposed to feedback onto the eddy field, acting to maintain the subtropical front eddy streets and thus the striations.

  9. Advances in Automated Plankton Imaging: Enhanced Throughput, Automated Staining, and Extended Deployment Modes for Imaging FlowCytobot

    NASA Astrophysics Data System (ADS)

    Sosik, H. M.; Olson, R. J.; Brownlee, E.; Brosnahan, M.; Crockford, E. T.; Peacock, E.; Shalapyonok, A.

    2016-12-01

    Imaging FlowCytobot (IFCB) was developed to fill a need for automated identification and monitoring of nano- and microplankton, especially phytoplankton in the size range 10 200 micrometer, which are important in coastal blooms (including harmful algal blooms). IFCB uses a combination of flow cytometric and video technology to capture high resolution (1 micrometer) images of suspended particles. This proven, now commercially available, submersible instrument technology has been deployed in fixed time series locations for extended periods (months to years) and in shipboard laboratories where underway water is automatically analyzed during surveys. Building from these successes, we have now constructed and evaluated three new prototype IFCB designs that extend measurement and deployment capabilities. To improve cell counting statistics without degrading image quality, a high throughput version (IFCB-HT) incorporates in-flow acoustic focusing to non-disruptively pre-concentrate cells before the measurement area of the flow cell. To extend imaging to all heterotrophic cells (even those that do not exhibit chlorophyll fluorescence), Staining IFCB (IFCB-S) incorporates automated addition of a live-cell fluorescent stain (fluorescein diacetate) to samples before analysis. A horizontally-oriented IFCB-AV design addresses the need for spatial surveying from surface autonomous vehicles, including design features that reliably eliminate air bubbles and mitigate wave motion impacts. Laboratory evaluation and test deployments in waters near Woods Hole show the efficacy of each of these enhanced IFCB designs.

  10. Background-Oriented Schlieren for Large-Scale and High-Speed Aerodynamic Phenomena

    NASA Technical Reports Server (NTRS)

    Mizukaki, Toshiharu; Borg, Stephen; Danehy, Paul M.; Murman, Scott M.; Matsumura, Tomoharu; Wakabayashi, Kunihiko; Nakayama, Yoshio

    2015-01-01

    Visualization of the flow field around a generic re-entry capsule in subsonic flow and shock wave visualization with cylindrical explosives have been conducted to demonstrate sensitivity and applicability of background-oriented schlieren (BOS) for field experiments. The wind tunnel experiment suggests that BOS with a fine-pixel imaging device has a density change detection sensitivity on the order of 10(sup -5) in subsonic flow. In a laboratory setup, the structure of the shock waves generated by explosives have been successfully reconstructed by a computed tomography method combined with BOS.

  11. Flow cytometry: a promising technique for the study of silicone oil-induced particulate formation in protein formulations.

    PubMed

    Ludwig, D Brett; Trotter, Joseph T; Gabrielson, John P; Carpenter, John F; Randolph, Theodore W

    2011-03-15

    Subvisible particles in formulations intended for parenteral administration are of concern in the biopharmaceutical industry. However, monitoring and control of subvisible particulates can be complicated by formulation components, such as the silicone oil used for the lubrication of prefilled syringes, and it is difficult to differentiate microdroplets of silicone oil from particles formed by aggregated protein. In this study, we demonstrate the ability of flow cytometry to resolve mixtures comprising subvisible bovine serum albumin (BSA) aggregate particles and silicone oil emulsion droplets with adsorbed BSA. Flow cytometry was also used to investigate the effects of silicone oil emulsions on the stability of BSA, lysozyme, abatacept, and trastuzumab formulations containing surfactant, sodium chloride, or sucrose. To aid in particle characterization, the fluorescence detection capabilities of flow cytometry were exploited by staining silicone oil with BODIPY 493/503 and model proteins with Alexa Fluor 647. Flow cytometric analyses revealed that silicone oil emulsions induced the loss of soluble protein via protein adsorption onto the silicone oil droplet surface. The addition of surfactant prevented protein from adsorbing onto the surface of silicone oil droplets. There was minimal formation of homogeneous protein aggregates due to exposure to silicone oil droplets, although oil droplets with surface-adsorbed trastuzumab exhibited flocculation. The results of this study demonstrate the utility of flow cytometry as an analytical tool for monitoring the effects of subvisible silicone oil droplets on the stability of protein formulations. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. Enzymatic signal amplification for sensitive detection of intracellular antigens by flow cytometry.

    PubMed

    Karkmann, U; Radbruch, A; Hölzel, V; Scheffold, A

    1999-11-19

    Flow cytometry is the method of choice for the analysis of single cells with respect to the expression of specific antigens. Antigens can be detected with specific antibodies either on the cell surface or within the cells, after fixation and permeabilization of the cell membrane. Using conventional fluorochrome-labeled antibodies several thousand antigens are required for clear-cut separation of positive and negative cells. More sensitive reagents, e.g., magnetofluorescent liposomes conjugated to specific antibodies permit the detection of less than 200 molecules per cell but cannot be used for the detection of intracellular antigens. Here, we describe an enzymatic amplification technique (intracellular tyramine-based signal amplification, ITSA) for the sensitive cytometric analysis of intracellular cytokines by immunofluorescence. This approach results in a 10 to 15-fold improvement of the signal-to-noise ratio compared to conventional fluorochrome labeled antibodies and permits the detection of as few as 300-400 intracellular antigens per cell.

  13. High-resolution FISH on super-stretched flow-sorted plant chromosomes.

    PubMed

    Valárik, M; Bartos, J; Kovárová, P; Kubaláková, M; de Jong, J H; Dolezel, J

    2004-03-01

    A novel high-resolution fluorescence in situ hybridisation (FISH) strategy, using super-stretched flow-sorted plant chromosomes as targets, is described. The technique that allows longitudinal extension of chromosomes of more than 100 times their original metaphase size is especially attractive for plant species with large chromosomes, whose pachytene chromosomes are generally too long and heterochromatin patterns too complex for FISH analysis. The protocol involves flow cytometric sorting of metaphase chromosomes, mild proteinase-K digestion of air-dried chromosomes on microscopic slides, followed by stretching with ethanol:acetic acid (3 : 1). Stretching ratios were assessed in a number of FISH experiments with super-stretched chromosomes from barley, wheat, rye and chickpea, hybridised with 45S and 5S ribosomal DNAs and the [GAA]n microsatellite, the [TTTAGGG]n telomeric repeat and a bacterial artificial chromosome (BAC) clone as probes. FISH signals on stretched chromosomes were brighter than those on the untreated control, resulting from better accessibility of the stretched chromatin and maximum observed sensitivity of 1 kbp. Spatial resolution of neighbouring loci was improved down to 70 kbp as compared to 5-10 Mbp after FISH on mitotic chromosomes, revealing details of adjacent DNA sequences hitherto not obtained with any other method. Stretched chromosomes are advantageous over extended DNA fibres from interphase nuclei as targets for FISH studies because they still retain chromosomal integrity. Although the method is confined to species for which chromosome flow sorting has been developed, it provides a unique system for controlling stretching degree of mitotic chromosomes and high-resolution bar-code FISH.

  14. The life-cycle of Emiliania huxleyi: A brief review and a study of relative ploidy levels analysed by flow cytometry

    NASA Astrophysics Data System (ADS)

    Green, J. C.; Course, P. A.; Tarran, G. A.

    1996-10-01

    Emiliania huxleyi exists in several principal forms including the familiar coccolith-bearing C-cell, non-motile naked N-cells, and scale-bearing swarmers (S-cells), but the relationships between these cells are unclear. Flow cytometric analyses have been undertaken on whole cells using fluorochrome staining of the DNA in order to determine the relative DNA content and the relative GC content of the S- and C-cells of selected clones. Results showed that the DNA complement of the S-cells was half that of the C-cells and the two cell types are, therefore, haploid and diploid relative to each other. The S-cells may, therefore, represent a gametic stage, though processes such as sexual fusion and meiosis have not been observed.

  15. Measurement of lipocortin 1 levels in murine peripheral blood leukocytes by flow cytometry: modulation by glucocorticoids and inflammation.

    PubMed

    Perretti, M; Flower, R J

    1996-06-01

    1. Lipocortin 1 (LC1) immunoreactivity in murine peripheral blood leukocytes was quantified by use of a flow cytometric technique associated with a permeabilisation protocol with saponin. Using specific antisera raised against the whole protein or against its N-terminus peptide, cell-associated LC1-like immunoreactivity was easily detected in circulating neutrophils and monocytes, whereas very low levels were found in lymphocytes. Of the total protein measured 17.6% and 36% were associated with the external plasma membrane in neutrophils and monocytes, as assessed in the absence of cell permeabilisation, whereas no signal was detected on lymphocyte plasma membrane. 2. Treatment of mice with dexamethasone (Dex; 0.5-5 micrograms per mouse corresponding to approximately 0.015-1.5 mg kg-1) increased LC1 levels in neutrophils and monocytes. The 2-3 fold increase in LC1 levels was time-dependent with a peak at 2 h. Treatment of mice with the steroid antagonist, RU486 (two doses of 20 mg kg-1 orally) decreased LC1-like immunoreactivity in all three types of circulating leukocytes by > or = 50%. 3. Extravasation of blood neutrophils into inflamed tissue sites resulted in a consistent reduction (> or = 50%) in LC1 levels compared with circulating neutrophils. A high LC1-like immunoreactivity was also measured in resident macrophages, of which approximately one third was membrane-associated. Induction of an acute inflammatory response in the murine peritoneal cavity did not modify total LC1 levels measured in macrophages, but reduced membrane-associated LC1 to a significant extent, i.e. up to 70%. 4. In conclusion, flow cytometric analysis is a rapid and convenient method for detecting and measuring LC1 in murine leukocytes. We confirmed that LC1 protein expression is controlled by exogenous and endogenous glucocorticoids. Amongst other factor(s) influencing protein concentrations, extravasation was found to be associated with a reduced LC1 expression in the emigrated cells.

  16. Comparative analysis of minimal residual disease detection using four-color flow cytometry, consensus IgH-PCR, and quantitative IgH PCR in CLL after allogeneic and autologous stem cell transplantation.

    PubMed

    Böttcher, S; Ritgen, M; Pott, C; Brüggemann, M; Raff, T; Stilgenbauer, S; Döhner, H; Dreger, P; Kneba, M

    2004-10-01

    The clinically most suitable method for minimal residual disease (MRD) detection in chronic lymphocytic leukemia is still controversial. We prospectively compared MRD assessment in 158 blood samples of 74 patients with CLL after stem cell transplantation (SCT) using four-color flow cytometry (MRD flow) in parallel with consensus IgH-PCR and ASO IgH real-time PCR (ASO IgH RQ-PCR). In 25 out of 106 samples (23.6%) with a polyclonal consensus IgH-PCR pattern, MRD flow still detected CLL cells, proving higher sensitivity of flow cytometry over PCR-genescanning with consensus IgH-primers. Of 92 samples, 14 (15.2%) analyzed in parallel by MRD flow and by ASO IgH RQ-PCR were negative by our flow cytometric assay but positive by PCR, thus demonstrating superior sensitivity of RQ-PCR with ASO primers. Quantitative MRD levels measured by both methods correlated well (r=0.93). MRD detection by flow and ASO IgH RQ-PCR were equally suitable to monitor MRD kinetics after allogeneic SCT, but the PCR method detected impending relapses after autologous SCT earlier. An analysis of factors that influence sensitivity and specificity of flow cytometry for MRD detection allowed to devise further improvements of this technique.

  17. An image cytometric technique is a concise method to detect adenoviruses and host cell proteins and to monitor the infection and cellular responses induced.

    PubMed

    Morinaga, Takao; Nguyễn, Thảo Thi Thanh; Zhong, Boya; Hanazono, Michiko; Shingyoji, Masato; Sekine, Ikuo; Tada, Yuji; Tatsumi, Koichiro; Shimada, Hideaki; Hiroshima, Kenzo; Tagawa, Masatoshi

    2017-11-10

    Genetically modified adenoviruses (Ad) with preferential replications in tumor cells have been examined for a possible clinical applicability as an anti-cancer agent. A simple method to detect viral and cellular proteins is valuable to monitor the viral infections and to predict the Ad-mediated cytotoxicity. We used type 5 Ad in which the expression of E1A gene was activated by 5'-regulatory sequences of genes that were augmented in the expression in human tumors. The Ad were further modified to have the fiber-knob region replaced with that derived from type 35 Ad. We infected human mesothelioma cells with the fiber-replaced Ad, and sequentially examined cytotoxic processes together with an expression level of the viral E1A, hexon, and cellular cleaved caspase-3 with image cytometric and Western blot analyses. The replication-competent Ad produced cytotoxicity on mesothelioma cells. The infected cells expressed E1A and hexon 24 h after the infection and then showed cleavage of caspase-3, all of which were detected with image cytometry and Western blot analysis. Image cytometry furthermore demonstrated that increased Ad doses did not enhance an expression level of E1A and hexon in an individual cell and that caspase-3-cleaved cells were found more frequently in hexon-positive cells than in E1A-positive cells. Image cytometry thus detected these molecular changes in a sensitive manner and at a single cell level. We also showed that an image cytometric technique detected expression changes of other host cell proteins, cyclin-E and phosphorylated histone H3 at a single cell level. Image cytometry is a concise procedure to detect expression changes of Ad and host cell proteins at a single cell level, and is useful to analyze molecular events after the infection.

  18. Bronchoalveolar Lavage Fluid Characteristics of Patients With Sarcoidosis and Nonsarcoidosis Interstitial Lung Diseases: Ten-Year Experience of a Single Center in Turkey

    PubMed Central

    Tanriverdi, Hakan; Erboy, Fatma; Altinsoy, Bulent; Uygur, Firat; Arasli, Mehmet; Ozel Tekin, Ishak; Tor, Muge Meltem; Atalay, Figen

    2015-01-01

    Background: Bronchoalveolar lavage (BAL) is a noninvasive and useful technique for evaluating interstitial lung diseases (ILDs). Flow cytometric analysis of BAL fluid reveals specific diagnostic information in some unusual ILDs, and helps to narrow down the possible causes of interstitial diseases in most patients with more common disorders. A high BAL CD4/CD8 ratio is highly specific for sarcoidosis but can also be seen in other ILDs. Objectives: In this retrospective, descriptive, cross-sectional study, we compared BAL fluid characteristics and clinical variables in patients with sarcoidosis and non-sarcoidosis ILDs in a large cohort. Patients and Methods: The study was conducted in a tertiary university hospital in Zonguldak, the biggest city of the western Black Sea region of Turkey. Between 2004 and 2014, all patients who underwent both fiberoptic bronchoscopy and BAL with a suspicion of ILD were included in the study, retrospectively. Patients were divided into two main groups: sarcoidosis and non-sarcoidosis ILDs. Non-sarcoidosis ILDs were further divided into subgroups: pneumoconiosis, tuberculosis (TB), collagen vascular diseases, idiopathic interstitial pneumonias, malignancies, and unclassified ILDs. The clinical data of patients, including age, gender, smoking status, pulmonary function tests, and BAL flow cytometric analysis results, were compared among groups. Results: In total, 261 patients (119 sarcoidosis and 142 non-sarcoidosis ILDs) were enrolled. The median (interquartile range) BAL CD4/CD8 ratio and lymphocyte fraction were significantly higher in sarcoidosis than in non-sarcoidosis ILDs: 3.88 (3.76) versus 0.88 (1.01), respectively, and 20.6 (28.3) versus 6.0 (13.7), respectively. T cell receptor γ delta, CD16+56+, CD103+, CD8+103+, and CD3+16+56+ cells were significantly lower in sarcoidosis than in non-sarcoidosis ILDs. The median BAL CD4/CD8 ratios were significantly higher in patients with TB (1.87, P = 0.01) and malignancies (1.69, P = 0

  19. Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method.

    PubMed

    Prest, E I; Hammes, F; Kötzsch, S; van Loosdrecht, M C M; Vrouwenvelder, J S

    2013-12-01

    Flow cytometry (FCM) is a rapid, cultivation-independent tool to assess and evaluate bacteriological quality and biological stability of water. Here we demonstrate that a stringent, reproducible staining protocol combined with fixed FCM operational and gating settings is essential for reliable quantification of bacteria and detection of changes in aquatic bacterial communities. Triplicate measurements of diverse water samples with this protocol typically showed relative standard deviation values and 95% confidence interval values below 2.5% on all the main FCM parameters. We propose a straightforward and instrument-independent method for the characterization of water samples based on the combination of bacterial cell concentration and fluorescence distribution. Analysis of the fluorescence distribution (or so-called fluorescence fingerprint) was accomplished firstly through a direct comparison of the raw FCM data and subsequently simplified by quantifying the percentage of large and brightly fluorescent high nucleic acid (HNA) content bacteria in each sample. Our approach enables fast differentiation of dissimilar bacterial communities (less than 15 min from sampling to final result), and allows accurate detection of even small changes in aquatic environments (detection above 3% change). Demonstrative studies on (a) indigenous bacterial growth in water, (b) contamination of drinking water with wastewater, (c) household drinking water stagnation and (d) mixing of two drinking water types, univocally showed that this FCM approach enables detection and quantification of relevant bacterial water quality changes with high sensitivity. This approach has the potential to be used as a new tool for application in the drinking water field, e.g. for rapid screening of the microbial water quality and stability during water treatment and distribution in networks and premise plumbing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Detection of DNA damage in individual cells by flow cytometric analysis using anti-DNA monoclonal antibody

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frankfurt, O.S.

    A new method for the measurement of DNA damage in individual cells treated with alkylating agents is described. The method is based on the binding of anti-DNA monoclonal antibody to DNA in situ. Binding of antibody was evaluated by flow cytometry with indirect immunofluorescence. No binding of antibody to DNA in non-treated HeLa S3 cells was detected. Treatment of cells with HN2 or L-phenylalanine mustard induced binding of antibody to DNA in situ. Binding of antibody was observed after treating cells with doses of drugs which reduced the surviving fraction below 20%. Intensity of binding increased in proportion to themore » drug dose. In HN2-treated cells a cell subset with the lowest antibody binding was observed among cells in G1 phase. Binding of antibody to DNA in HN2-treated cells was eliminated by single-strand (ss) specific S1 nuclease. In competition assay, antibody was inhibited by thermally denatured DNA, but not by native double-stranded (ds) DNA, RNA, nucleosides and deoxyribohomopolymers. Immunoreactivity of cells with the monoclonal antibody F7-26 may be a useful probe for the assessment of cell damage induced by alkylating agents, especially in heterogeneous cell populations.« less

  1. Adaptation of the TdT assay for semi-quantitative flow cytometric detection of DNA strand breaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bromidge, T.J.; Howe, D.J.; Johnson, S.A.

    The enzyme Terminal Deoxynucleotidyl Transferase (TdT) is a DNA polymerase which can be used to label DNA strand breaks by the incorporation of a labelled nucleotide followed by a fluorescent detection step. The amount of label incorporated can then be assessed by flow cytometry. The mechanism of action of TdT, however, will allow the addition of varying numbers of nucleotides to the free 3{prime} termini produced by DNA strand breaks. The substitution of Digoxigenin (DIG){trademark} labelled dideoxynucleotides for labelled deoxy-nucleotides in the TdT assay will limit the addition of label to a DNA break to a single nucleotide, thus ensuringmore » a direct relationship between an increase in DNA strand breaks and an increase in fluorescence. We have used this adaptation of the TdT assay to evaluate DNA damage incurred in lymphocytes, from patients with Chronic Lymphocytic Leukemia (CLL), on exposure to UV irradiation and apoptosis-inducing drugs, fludarabine and 2-Chloro-2{prime}-deoxyadenosine (2-CdA). This technique may give a good indication of the susceptibility of CLL patients to apoptosis inducing drugs, and hence an indication of the likely response to these therapies. 7 refs., 2 figs., 2 tabs.« less

  2. Genetic stock assessment of spawning arctic cisco (Coregonus autumnalis) populations by flow cytometric determination of DNA content.

    PubMed

    Lockwood, S F; Bickham, J W

    1991-01-01

    Intraspecific variation in cellular DNA content was measured in five Coregonus autumnalis spawning populations from the Mackenzie River drainage, Canada, using flow cytometry. The rivers assayed were the Peel, Arctic Red, Mountain, Carcajou, and Liard rivers. DNA content was determined from whole blood preparations of fish from all rivers except the Carcajou, for which kidney tissue was used. DNA content measurements of kidney and blood preparations of the same fish from the Mountain River revealed statistically indistinguishable results. Mosaicism was found in blood preparations from the Peel, Arctic Red, Mountain, and Liard rivers, but was not observed in kidney tissue preparations from the Mountain or Carcajou rivers. The Liard River sample had significantly elevated mean DNA content relative to the other four samples; all other samples were statistically indistinguishable. Significant differences in mean DNA content among spawning stocks of a single species reinforces the need for adequate sample sizes of both individuals and populations when reporting "C" values for a particular species.

  3. Interlaboratory assessment of mitotic index by flow cytometry confirms superior reproducibility relative to microscopic scoring.

    PubMed

    Roberts, D J; Spellman, R A; Sanok, K; Chen, H; Chan, M; Yurt, P; Thakur, A K; DeVito, G L; Murli, H; Stankowski, L F

    2012-05-01

    A flow cytometric procedure for determining mitotic index (MI) as part of the metaphase chromosome aberrations assay, developed and utilized routinely at Pfizer as part of their standard assay design, has been adopted successfully by Covance laboratories. This method, using antibodies against phosphorylated histone tails (H3PS10) and nucleic acid stain, has been evaluated by the two independent test sites and compared to manual scoring. Primary human lymphocytes were treated with cyclophosphamide, mitomycin C, benzo(a)pyrene, and etoposide at concentrations inducing dose-dependent cytotoxicity. Deming regression analysis indicates that the results generated via flow cytometry (FCM) were more consistent between sites than those generated via microscopy. Further analysis using the Bland-Altman modification of the Tukey mean difference method supports this finding, as the standard deviations (SDs) of differences in MI generated by FCM were less than half of those generated manually. Decreases in scoring variability owing to the objective nature of FCM, and the greater number of cells analyzed, make FCM a superior method for MI determination. In addition, the FCM method has proven to be transferable and easily integrated into standard genetic toxicology laboratory operations. Copyright © 2012 Wiley Periodicals, Inc.

  4. Determination by flow cytometry polyploidy inducing-capacity of colchicine in Cajanus cajan (L.) Mill sp.

    PubMed

    Udensi, O U; Ontui, V

    2013-07-01

    The need to optimize flow cytometric analysis for the determination of ploidy level is a worthwhile venture to precisely know at what concentration of a mutagen and at what time of exposure polyploidy could be induced. Flow cytometry was used to determine the polyploidy inducing-capacity of colchicine in pigeon pea (Cajanus cajan (L.) Mill sp). Seeds of pigeon pea were soaked in three different concentrations of colchicine-5 mg, 10 and 15 mg L(-1) for 24, 48 and 72 h, respectively, while the control group was soaked in water. Treated seeds and those from the control were planted in a greenhouse using a Completely Randomized Design (CRD). Results show that colchicine induced tetraploids (4n) and mixoploids (2n+ 4n) as the concentration of colchicine increased and soaking duration. Days to seedling emergence increased as concentration of colchicine and duration of soaking increased while germination rate decreased proportionately with the increase in colchicine concentration and soaking duration but did not significantly affect percentage seedling survival. Explicitly, colchicine has the capacity of inducing polyploidy; especially tetraploids on the seeds of pigeon pea, which obviously could be harnessed for further breeding and improvement of the pigeon pea.

  5. Navigation to the graveyard-induction of various pathways of necrosis and their classification by flow cytometry.

    PubMed

    Janko, Christina; Munoz, Luis; Chaurio, Ricardo; Maueröder, Christian; Berens, Christian; Lauber, Kirsten; Herrmann, Martin

    2013-01-01

    Apoptosis and necrosis reflect the program of cell death employed by a dying cell and the final stage of death, respectively. Whereas apoptosis is defined as a physiological, highly organized cell death process, necrosis is commonly considered to be accidental and uncontrolled. Physiological and weak pathological death stimuli preferentially induce apoptosis, while harsh non-physiological insults often immediately instigate (primary) necrosis. If an apoptosing cell transits into a phase of plasma membrane disintegration, this stage of death is referred to as secondary or post-apoptotic necrosis.Here, we present several conditions that stimulate primary and/or secondary necrosis and show that necrosis displays considerably different time courses. For subclassification of necrotic phenotypes we employed a flow cytometric single-tube 4-color staining technique including annexin A5-FITC, propidium iodide, DiIC1(5), and Hoechst 33342.

  6. Emergent kink stability of a magnetized plasma jet injected into a transverse background magnetic field

    NASA Astrophysics Data System (ADS)

    Zhang, Yue; Gilmore, Mark; Hsu, Scott C.; Fisher, Dustin M.; Lynn, Alan G.

    2017-11-01

    We report experimental results on the injection of a magnetized plasma jet into a transverse background magnetic field in the HelCat linear plasma device at the University of New Mexico [M. Gilmore et al., J. Plasma Phys. 81(1), 345810104 (2015)]. After the plasma jet leaves the plasma-gun muzzle, a tension force arising from an increasing curvature of the background magnetic field induces in the jet a sheared axial-flow gradient above the theoretical kink-stabilization threshold. We observe that this emergent sheared axial flow stabilizes the n = 1 kink mode in the jet, whereas a kink instability is observed in the jet when there is no background magnetic field present.

  7. Applications of Flow Cytometry to Clinical Microbiology†

    PubMed Central

    Álvarez-Barrientos, Alberto; Arroyo, Javier; Cantón, Rafael; Nombela, César; Sánchez-Pérez, Miguel

    2000-01-01

    Classical microbiology techniques are relatively slow in comparison to other analytical techniques, in many cases due to the need to culture the microorganisms. Furthermore, classical approaches are difficult with unculturable microorganisms. More recently, the emergence of molecular biology techniques, particularly those on antibodies and nucleic acid probes combined with amplification techniques, has provided speediness and specificity to microbiological diagnosis. Flow cytometry (FCM) allows single- or multiple-microbe detection in clinical samples in an easy, reliable, and fast way. Microbes can be identified on the basis of their peculiar cytometric parameters or by means of certain fluorochromes that can be used either independently or bound to specific antibodies or oligonucleotides. FCM has permitted the development of quantitative procedures to assess antimicrobial susceptibility and drug cytotoxicity in a rapid, accurate, and highly reproducible way. Furthermore, this technique allows the monitoring of in vitro antimicrobial activity and of antimicrobial treatments ex vivo. The most outstanding contribution of FCM is the possibility of detecting the presence of heterogeneous populations with different responses to antimicrobial treatments. Despite these advantages, the application of FCM in clinical microbiology is not yet widespread, probably due to the lack of access to flow cytometers or the lack of knowledge about the potential of this technique. One of the goals of this review is to attempt to mitigate this latter circumstance. We are convinced that in the near future, the availability of commercial kits should increase the use of this technique in the clinical microbiology laboratory. PMID:10755996

  8. Flow cytometric analysis of normal and neoplastic mast cells: role in diagnosis and follow-up of mast cell disease.

    PubMed

    Escribano, Luis; Garcia Montero, Andres C; Núñez, Rosa; Orfao, Alberto

    2006-08-01

    Human mast cells (MCs) are directly derived from human pluripotent CD34+ stem and progenitor hematopoietic cells with stem cell factor being a critical growth factor supporting human MC proliferation, differentiation, and survival. Because of the advantages that flow cytometry offers (it allows rapid, objective, and sensitive multiparameter analysis of high numbers of cells from a sample, with information being provided on the basis of a single cell), it has become the method of choice in the past decade for immunophenotypic identification, enumeration, and characterization of human MCs in bone marrow and other tissue specimens.

  9. Characterization of Vacuum Facility Background Gas Through Simulation and Considerations for Electric Propulsion Ground Testing

    NASA Technical Reports Server (NTRS)

    Yim, John T.; Burt, Jonathan M.

    2015-01-01

    The background gas in a vacuum facility for electric propulsion ground testing is examined in detail through a series of cold flow simulations using a direct simulation Monte Carlo (DSMC) code. The focus here is on the background gas itself, its structure and characteristics, rather than assessing its interaction and impact on thruster operation. The background gas, which is often incorrectly characterized as uniform, is found to have a notable velocity within a test facility. The gas velocity has an impact on the proper measurement of pressure and the calculation of ingestion flux to a thruster. There are also considerations for best practices for tests that involve the introduction of supplemental gas flows to artificially increase the background pressure. All of these effects need to be accounted for to properly characterize the operation of electric propulsion thrusters across different ground test vacuum facilities.

  10. Flow cytometry beads rather than the antihuman globulin method should be used to detect HLA Class I IgG antibody (PRA) in cadaveric renal regraft candidates.

    PubMed

    Bryan, Christopher F; McDonald, Scott B; Baier, Karen A; Luger, Alan M; Aeder, Mark I; Murillo, Daniel; Muruve, Nicolas A; Nelson, Paul W; Shield, Charles F; Warady, Bradley A

    2002-01-01

    HLA Class I antibody screening can be performed by flow cytometry using a mixture of 30 distinct bead populations each coated with the Class I antigen phenotype derived from different cell lines. In this study we compared the efficacy of Class I antibody screens done by flow cytometry beads with the antihuman globulin (AHG) method for patients awaiting cadaveric renal retransplantation. Class I panel reactive antibody (PRA) screening by flow cytometric beads of 21 regraft serum samples that had all been found to be negative by AHG DTT Class I PRA, revealed that 57.1% (12 of 21) had a flow Class I PRA of > or = 10%. Furthermore, when five regraft sera with an intermediate PRA were screened (mean AHG DTT PRA = 33.2 +/- 13%) the mean flow Class I PRA almost doubled (mean flow PRA = 72.4 +/- 10.2%) (p < 0.01). When active UNOS waiting list regraft candidates, after several months of screening the Class I PRA by flow beads, were divided into the three PRA categories based on their peak flow Class I PRA value (0-20%, 21-79% and > or = 80%), the incidence of a positive flow cross-match was 0%, 72% and 85% and the incidence of retransplantation was 60%, 22% and 10%, in each of these groups, respectively. These data provided our histocompatibility laboratory with the rationale to stop performing the AHG PRA and perform only the flow Class I PRA method for regraft candidates.

  11. Multiplexed flow cytometric sensing of blood electrolytes in physiological samples using fluorescent bulk optode microspheres.

    PubMed

    Xu, Chao; Wygladacz, Katarzyna; Retter, Robert; Bell, Michael; Bakker, Eric

    2007-12-15

    Polymeric bulk optode microsphere ion sensors in combination with suspension array technologies such as analytical flow cytometry may become a power tool for measuring electrolytes in physiological samples. In this work, the methodology for the direct measurement of common blood electrolytes in physiological samples using bulk optode microsphere sensors was explored. The simultaneous determination of Na(+), K(+), and Ca(2+) in diluted sheep blood plasma was demonstrated for the first time, using a random suspension array containing three types of mixed microsphere bulk optodes of similar size, fabricated from the same chromoionophore without additional labeling. Sodium ionophore X, potassium ionophore III, and grafted AU-1 in poly(butyl acrylate) were the ionophores used in the bulk optode microsphere ion sensors for Na(+), K(+), and Ca(2+), respectively, in combination with the cation-exchanger NaTFPB (sodium tetrakis-[3,5-bis(trifluoromethyl)phenyl]borate) and the same concentration of the chromoionophore ETH 5294 (9-(di-ethylamino)-5-octadecanoylimino-5H-benzo[a]phen-oxazine) in plasticized poly(vinyl chloride). Excellent reproducibility was achieved for the sensing of potassium ions. The effect of sample pH was relatively small at near-physiological pH and followed theoretical predictions, yet the sample temperature was found to influence the sensor response to a larger extent. Multiplexed ion sensing was achieved by taking advantage of the chemical tunability of the sensor response, adjusting the sensor compositions so that the three types of ion sensors responded with distinct levels of protonation of the chromoionophore. Consequently, three well-resolved peaks were simultaneously observed in the single-channel histogram during the multiplexed calibration as well as in the subsequent measurement of the three cations in 10-fold-diluted sheep plasma. The assigned peak positions corresponded very well to the physiological range of the measured ions.

  12. Quantitative analysis of gold and carbon nanoparticles in mammalian cells by flow cytometry light scattering

    NASA Astrophysics Data System (ADS)

    Zhou, Gang; Liu, Naicheng; Wang, Zhenheng; Shi, Tongguo; Gan, Jingjing; Wang, Zhenzhen; Zhang, Junfeng

    2017-02-01

    Nanoparticle-based applications for diagnostics and therapeutics have been extensively studied. These applications require a profound understanding of the fate of nanoparticles (NPs) in cellular environments. However, until now, few analytical methods are available and most of them rely on fluorescent properties or special elements of NPs; therefore, for NPs without observable optical properties or special elements, the existing methods are hardly applicable. In this study, we introduce a flow cytometry light scattering (FCLS)-based approach that quantifies in situ NPs accurately in mammalian cells. Continuous cells of heterogeneous human epithelial colorectal adenocarcinoma (Caco-2 cells), mouse peritoneal macrophages (MPM), and human adenocarcinomic alveolar basal epithelia (A549 cells) were cultured with NPs with certain concentrations and size. The intensity of the flow cytometric side scattered light, which indicates the quantity of NPs in the cells, was analyzed. The result shows an accurate size- and dose-dependent uptake of Au NPs (5, 30, 250 nm) in Caco-2 cells. The size- and dose- dependence of Au NPs (5, 30, 250 nm) and carbon NPs (50, 500 nm) in cells was validated by transmission electron microscope (TEM). This paper demonstrates the great potential of flow cytometry light scattering in the quantitative study of the size and dose effect on in situ metallic or non-metallic NPs in mammalian cells.

  13. Flow cytometric examination of apoptotic effect on brain tissue in postnatal period created by intrauterine oxcarbazepine and gabapentin exposure.

    PubMed

    Erisgin, Z; Tekelioglu, Y

    For epileptics, pregnancy contains the balance between no seizure period and antiepileptic use having the least teratogenicity risk. The purpose is to analyse with flow cytometry the apoptotic effects on postnatal brain tissue caused by prenatal use of second generation antiepileptics oxcarbazepine (OXC) and gabapentin (GBP) having different effect mechanisms. 30 (n = 5 each group) Wistar albino male rats (45-days-old) are used. First 3 groups are exposed to OXC (100 mg/kg/day), GBP (50 mg/kg/day), and saline, respectively on the 1st-5th prenatal days (preimplantation-implantation period) while the second 3 groups are exposed to the same substances on the 6th-15th prenatal days (organogenesis), respectively. After sacrifice, brain tissue samples were made into suspension with mechanic and enzymatic digestion and examined with flow cytometry. While apoptosis rate appeared high in rats exposed to OXC on the 1st-5th (p < 0.001) and 6th-15th days (p < 0.001), no significant difference occurred for GBP (p = 0.004; p = 0.012) and saline (p = 0.012). Considering time effect in three treatment groups, while difference was not significant for PSS and GBP groups (p = 0.847 and p = 0.934), apoptosis rate was significantly high for OXC on the 6th-15th days compared to the 1st-5th days (p < 0.001). It is observed that the use of OXC causes neurotoxicity during preimplantation, implantation and, especially, organogenesis period (neurogenesis) whereas GBP does not (Fig. 3, Ref. 32).

  14. Laboratory Tests of Multiplex Detection of PCR Amplicons Using the Luminex 100 Flow Analyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venkateswaran, K.S.; Nasarabadi, S.; Langlois, R.G.

    2000-05-05

    Lawrence Livermore National Laboratory (LLNL) demonstrated the power of flow cytometry in detecting the biological agents simulants at JFT III. LLNL pioneered in the development of advanced nucleic acid analyzer (ANM) for portable real time identification. Recent advances in flow cytometry provide a means for multiplexed nucleic acid detection and immunoassay of pathogenic microorganisms. We are presently developing multiplexed immunoassays for the simultaneous detection of different simulants. Our goal is to build an integrated instrument for both nucleic acid analysis and immuno detection. In this study we evaluated the Luminex LX 100 for concurrent identification of more than one PCRmore » amplified product. ANAA has real-time Taqman fluorescent detection capability for rapid identification of field samples. However, its multiplexing ability is limited by the combination of available fluorescent labels. Hence integration of ANAA with flow cytometry can give the rapidity of ANAA amplification and the multiplex capability of flow cytometry. Multiplexed flow cytometric analysis is made possible using a set of fluorescent latex microsphere that are individually identified by their red and infrared fluorescence. A green fluorochrome is used as the assay signal. Methods were developed for the identification of specific nucleic acid sequences from Bacillus globigii (Bg), Bacillus thuringensis (Bt) and Erwinia herbicola (Eh). Detection sensitivity using different reporter fluorochromes was tested with the LX 100, and also different assay formats were evaluated for their suitability for rapid testing. A blind laboratory trial was carried out December 22-27, 1999 to evaluate bead assays for multiplex identification of Bg and Bt PCR products. This report summarizes the assay development, fluorochrome comparisons, and the results of the blind trial conducted at LLNL for the laboratory evaluation of the LX 100 flow analyzer.« less

  15. Flow cytometry for immediate follow-up of drinking water networks after maintenance.

    PubMed

    Van Nevel, Sam; Buysschaert, Benjamin; De Roy, Karen; De Gusseme, Bart; Clement, Lieven; Boon, Nico

    2017-03-15

    Drinking water networks need maintenance every once in a while, either planned interventions or emergency repairs. When this involves opening of the water pipes, precautionary measures need to be taken to avoid contamination of the drinking water at all time. Drinking water suppliers routinely apply plating for faecal indicator organisms as quality control in such a situation. However, this takes at least 21 h of waiting time, which can be crucial when dealing with major supply pipes. A combination of flow cytometric (FCM) bacterial cell counts with FCM fingerprinting techniques is proposed in this study as a fast and sensitive additional technique. In three full scale situations, major supply pipes with 400-1050 mm diameter were emptied for maintenance, shock-chlorinated and flushed with large amounts of clean drinking water before taking back in operation. FCM measurements of the discharged flushing water revealed fast lowering and stabilizing bacterial concentrations once flushing is initiated. Immediate comparison with clean reference drinking water used for flushing was done, and the moment when both waters had similar bacterial concentrations was considered as the endpoint of the necessary flushing works. This was usually after 2-4 h of flushing. FCM fingerprinting, based on both bacteria and FCM background, was used as additional method to verify how similar flushing and reference samples were and yielded similar results. The FCM approved samples were several hours later approved as well by the drinking water supplier after plating and incubation for total Coliforms and Enterococci. These were used as decisive control to set the pipes back in operation. FCM proved to be a more conservative test than plating, yet it yielded immediate results. Application of these FCM methods can therefore avoid long unnecessary waiting times and large drinking water losses. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Flow cytometry-assisted rapid isolation of recombinant Plasmodium berghei parasites exemplified by functional analysis of aquaglyceroporin

    PubMed Central

    Kenthirapalan, Sanketha; Waters, Andrew P.; Matuschewski, Kai; Kooij, Taco W.A.

    2012-01-01

    The most critical bottleneck in the generation of recombinant Plasmodium berghei parasites is the mandatory in vivo cloning step following successful genetic manipulation. This study describes a new technique for rapid selection of recombinant P. berghei parasites. The method is based on flow cytometry to isolate isogenic parasite lines and represents a major advance for the field, in that it will speed the generation of recombinant parasites as well as cut down on animal use significantly. High expression of GFP during blood infection, a prerequisite for robust separation of transgenic lines by flow cytometry, was achieved. Isogenic recombinant parasite populations were isolated even in the presence of a 100-fold excess of wild-type (WT) parasites. Aquaglyceroporin (AQP) loss-of-function mutants and parasites expressing a tagged AQP were generated to validate this approach. aqp− parasites grow normally within the WT phenotypic range during blood infection of NMRI mice. Similarly, colonization of the insect vector and establishment of an infection after mosquito transmission were unaffected, indicating that AQP is dispensable for life cycle progression in vivo under physiological conditions, refuting its use as a suitable drug target. Tagged AQP localized to perinuclear structures and not the parasite plasma membrane. We suggest that flow-cytometric isolation of isogenic parasites overcomes the major roadblock towards a genome-scale repository of mutant and transgenic malaria parasite lines. PMID:23137753

  17. Flow cytometric DNA analysis of cirrhotic liver cells in patients with hepatocellular carcinoma can provide a new prognostic factor.

    PubMed

    Ruà, S; Comino, A; Fruttero, A; Torchio, P; Bouzari, H; Taraglio, S; Torchio, B; Capussotti, L

    1996-09-15

    DNA flow cytometry of hepatocellular carcinoma (HCC) cells has been investigated in many studies, but, to the best of our knowledge, there are no data on DNA analysis of cirrhotic parenchyma around the HCC. In this study, cell kinetics and ploidy of parenchymal cells around HCC were performed to ascertain if this would predict the possibility of recurrence in the cirrhotic areas. The DNA content of 93 cases of HCC and of cirrhotic liver around the tumor nodules was analyzed by flow cytometry. Ploidy and proliferative index of HCC and cirrhotic liver were compared with macroscopic, histologic, and clinical features of each case and linked with the behavior of these tumors. Survival curves were assessed according to the Kaplan-Meier method. A multivariate analysis based on Cox proportional hazards regression model was performed on cases of diploid cirrhosis cells in which the S-phase fraction was evaluable. The univariate analysis of survival suggested significant roles for age, number of intrahepatic nodules, Edmondson-Steiner's classification, portal invasion, vascular invasion, presence of necrosis, hepatitis B surface antigen, alpha-feto-protein, Child's score, ploidy, and S-phase fraction of HCC cells. The DNA analysis of the cirrhotic cells showed that polyploidy was dramatically reduced in patients with HCC, compared with normal hepatocytes, and aneuploid clones were present among diploid cells. High S-phase fraction of cirrhotic cells and Child-Pugh classification were the strongest independent parameters affecting the tumor behavior in this study. The results of this study suggest that S-phase fraction of cirrhotic liver parenchyma may be employed as a new parameter in the prognostic evaluation of HCC patients.

  18. Analysis of UV-excited fluorochromes by flow cytometry using near-ultraviolet laser diodes.

    PubMed

    Telford, William G

    2004-09-01

    Violet laser diodes have become common and reliable laser sources for benchtop flow cytometers. While these lasers are very useful for a variety of violet and some ultraviolet-excited fluorochromes (e.g., DAPI), they do not efficiently excite most UV-stimulated probes. In this study, the next generation of InGaN near-UV laser diodes (NUVLDs) emitting in the 370-375-nm range have been evaluated as laser sources for cuvette-based flow cytometers. Several NUVLDs, ranging in wavelength from 370 to 374 nm and in power level from 1.5 to 10 mW, were mounted on a BD Biosciences LSR II and evaluated for their ability to excite cells labeled with the UV DNA binding dye DAPI, several UV phenotyping fluorochromes (including Alexa Fluor 350, Marina Blue, and quantum dots), and the fluorescent calcium chelator indo-1. NUVLDs at the 8-10-mW power range gave detection sensitivity levels comparable to more powerful solid-state and ion laser sources, using low-fluorescence microsphere beads as measurement standards. NUVLDs at all tested power levels allowed extremely high-resolution DAPI cell cycle analysis, and sources in the 8-10-mW power range excited Alexa Fluor 350, Marina Blue, and a variety of quantum dots at virtually the same signal-to-noise ratios as more powerful UV sources. These evaluations indicate that near-UV laser diodes installed on a cuvette-based flow cytometer performed nearly as well as more powerful solid-state UV lasers on the same instrumentation, and comparably to more powerful ion lasers on a jet-in-air system, and. Despite their limited power, integration of these small and inexpensive lasers into benchtop flow cytometers should allow the use of flow cytometric applications requiring UV excitation on a wide variety of instruments. Copyright 2004 Wiley-Liss, Inc.

  19. Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

    NASA Technical Reports Server (NTRS)

    Spalt, Taylor B.; Brooks, Thomas F.; Fuller, Christopher R.

    2012-01-01

    Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

  20. Level 2 validation of a flow cytometric method for detection of Escherichia coli O157:H7 in raw spinach.

    PubMed

    Williams, Anna J; Cooper, Willie M; Summage-West, Christine V; Sims, Lillie M; Woodruff, Robert; Christman, Jessica; Moskal, Ted J; Ramsaroop, Shawn; Sutherland, John B; Alusta, Pierre; Wilkes, Jon G; Buzatu, Dan A

    2015-12-23

    The Bacteriological Analytical Manual (BAM) method currently used by the United States Food and Drug Administration (FDA) to detect Escherichia coli O157:H7 in spinach was systematically compared to a new flow cytometry based method. This Food and Drug Administration (FDA) level 2 external laboratory validation study was designed to determine the latter method's sensitivity and speed for analysis of this pathogen in raw spinach. Detection of target cell inoculations with a low cell count is critical, since enterohemorrhagic strains of E. coli require an infective dose of as few as 10 cells (Schmid-Hempel and Frank, 2007). Although, according to the FDA, the infectious dose is unknown (Food and Drug Administration, 1993). Therefore, the inoculation level into the spinach, a total of 2.0±2.6 viable E. coli O157 cells, was specified to yield between 25% and 75% detection by the new method, out of 20 samples (10 positives and 10 negatives). This criterion was met in that the new method detected 60% of the nominally positive samples; the corresponding sensitivity of the reference method was 50%. For both methods the most likely explanation for false negatives was that no viable cells were actually introduced into the sample. In this validation study, the flow cytometry method was equal to the BAM in sensitivity and far superior in speed. Published by Elsevier B.V.

  1. Generation of anti-porcine CD69 monoclonal antibodies and their usefulness to evaluate early activation of cellular immunity by flow cytometric analysis.

    PubMed

    Hayashi, Yumiko; Okutani, Mie; Ogawa, Shohei; Tsukahara, Takamitsu; Inoue, Ryo

    2018-05-01

    T cell-mediated cellular immunity and humoral immunity are equally important for the prevention of diseases. To assess activation of human and mouse cellular immunity, early activation markers of lymphocytes are often used in flow cytometry targeting expression of CD69 molecules. Response of humoral immunity against infection or vaccination has been well investigated in pigs, but that of cellular immunity has been largely neglected due to lack of direct evaluation tools. Thus, in pig research a proper assay of antibody reacted with porcine CD69 is still unavailable. In the present study, two anti-porcine CD69 mAb-producing mouse hybridomas, 01-14-22-51 (IgG2b-κ) and 01-22-44-102 (IgG2a-κ), both showing fine reactivity with phorbol 12-myristate 13-acetate (PMA) and ionomycin-stimulated porcine peripheral blood lymphocytes in flow cytometry, were established. When porcine peripheral blood lymphocytes were activated with PMA and ionomycin and analyzed by flow cytometry, it was found that both mAbs generated in this study stained about 70% of lymphocytes. In contrast, after an identical procedure, only 5% and 13.5% of lymphocytes were stained with anti-interferon-γ mAb and anti-tumor necrosis factor-α mAb, respectively. These results indicate that evaluation of cellular immunity activation turns more sensitive after using our newly generated mAbs. © 2018 Japanese Society of Animal Science.

  2. Flow Cytometry Enables Multiplexed Measurements of Genetically Encoded Intramolecular FRET Sensors Suitable for Screening.

    PubMed

    Doucette, Jaimee; Zhao, Ziyan; Geyer, Rory J; Barra, Melanie M; Balunas, Marcy J; Zweifach, Adam

    2016-07-01

    Genetically encoded sensors based on intramolecular FRET between CFP and YFP are used extensively in cell biology research. Flow cytometry has been shown to offer a means to measure CFP-YFP FRET; we suspected it would provide a unique way to conduct multiplexed measurements from cells expressing different FRET sensors, which is difficult to do with microscopy, and that this could be used for screening. We confirmed that flow cytometry accurately measures FRET signals using cells transiently transfected with an ERK activity reporter, comparing responses measured with imaging and cytometry. We created polyclonal long-term transfectant lines, each expressing a different intramolecular FRET sensor, and devised a way to bar-code four distinct populations of cells. We demonstrated the feasibility of multiplexed measurements and determined that robust multiplexed measurements can be conducted in plate format. To validate the suitability of the method for screening, we measured responses from a plate of bacterial extracts that in unrelated experiments we had determined contained the protein kinase C (PKC)-activating compound teleocidin A-1. The multiplexed assay correctly identifying the teleocidin A-1-containing well. We propose that multiplexed cytometric FRET measurements will be useful for analyzing cellular function and for screening compound collections. © 2016 Society for Laboratory Automation and Screening.

  3. Cytometric analysis of shape and DNA content in mammalian sperm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gledhill, B.L.

    1983-10-10

    Male germ cells respond dramatically to a variety of insults and are important reproductive dosimeters. Semen analyses are very useful in studies on the effects of drugs, chemicals, and environmental hazards on testicular function, male fertility and heritable germinal mutations. Sperm were analyzed by flow cytometry and slit-scan flow analysis for injury following the exposure of testes to mutagens. The utility of flow cytometry in genotoxin screening and monitoring of occupational exposure was evaluated. The technique proved valuable in separation of X- and Y-chromosome bearing sperm and the potential applicability of this technique in artificial insemination and a solution, ofmore » accurately assessing the DNA content of sperm were evaluated-with reference to determination of X- and Y-chromosome bearing sperm.« less

  4. Flow cytometric bacterial cell counts challenge conventional heterotrophic plate counts for routine microbiological drinking water monitoring.

    PubMed

    Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F

    2017-04-15

    Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Flow Cytometric Ploidy Determination of Oral Premalignant and Malignant Lesions

    DTIC Science & Technology

    1990-01-01

    could advantageously influence patient management. REVIEW OF LITERATURE 3 ORAL PRECANCER As early as 1957 the World Health Organization 1 (WHO...euploid lichenoid mucositis was combined with eosinophilia 88 as the diagnosis of the intermediate lesion in case 6 and occurred a year after the...International Histological Classification of Tumours, No. 4. Geneva, World Health Organization, 1971, p. 23. 3. Pindborg, J.J.: Premalignant and malignant

  6. Flow cytometric analysis of leukocytes and reticulocytes stained with proflavine.

    PubMed

    Sagawa, H; Tatsumi, N

    1997-12-01

    Proflavine, an acridine analog for industrial use, was used to stain blood cells. A drop of blood treated with ethylenediaminetetraacetic acid-2K was mixed with a 0.00001% solution of the dye and observed immediately by fluorescence microscopy with a green filter. Leukocytes, platelets, and reticulocytes were stained but mature red blood cells were not. Chromatin in the nuclei of all leukocytes and nucleoli of lymphocytes and monocytes had greenish-yellow fluorescence, and the kind of cell could be identified by the tone and intensity of this color. Granules in granulocytes were in green. Reticular fine-granular or granulofibrous structures in the reticulocytes were brownish. The proflavine could be used routinely in clinical laboratories because this single stain makes possible simultaneous differentiation of leukocytes and counting of reticulocytes.

  7. Rapid Flow cytometric prenatal diagnosis of primary immunodeficiency (PID) disorders.

    PubMed

    Mishra, Anju; Gupta, Maya; Dalvi, Aparna; Ghosh, Kanjaksha; Madkaikar, Manisha

    2014-04-01

    Primary Immunodeficiency diseases (PID) are a heterogeneous group of inherited disorders of immune system. Immunophenotypic evaluation of PIDs using flowcytometry provides important clues for diagnosis of these disorders, though confirmation requires identification of underlying molecular defects. Prenatal diagnosis (PND) forms an important component of management in families affected with severe PID. However, molecular diagnostic facilities for each of these diseases are not available and may not be possible to perform in all cases. In such scenario we opted for phenotypic prenatal diagnosis by cordocentesis for families with index case having immunophenotypically well characterized PID. Normal reference ranges of lymphocyte subsets, CD 18/CD11 integrins on leukocytes, MHC class II expression and oxidative burst activity of fetal neutrophils at 18 weeks of gestation were previously established on 30 cord blood samples. PND was performed in 13 families with PIDs. Maternal contamination was ruled out by VNTR analysis. Out of 13 fetuses, nine were found to be unaffected (three cases with leukocyte adhesion deficiency (LAD-I), four cases with severe combined immunodeficiency diseases (SCID), one with X-linked agammaglobulinemia (XLA), and one with chronic granulomatous disease (CGD)] and three were found to be affected (one with T-B+NK-SCID, one with MHC class II deficiency and one with LAD-I). Diagnosis was confirmed by testing the cord blood samples after delivery and further follow-up of the children. In one family diagnosis could not be offered due to maternal contamination. No procedure related complications were observed. Flowcytometry offers rapid and sensitive method for prenatal diagnosis and genetic counseling for selected phenotypically well characterized PID in cases where molecular diagnostic facilities are not available.

  8. Functional and cytometric examination of different human lung epithelial cell types as drug transport barriers.

    PubMed

    Min, Kyoung Ah; Rosania, Gus R; Kim, Chong-Kook; Shin, Meong Cheol

    2016-03-01

    To develop inhaled medications, various cell culture models have been used to examine the transcellular transport or cellular uptake properties of small molecules. For the reproducible high throughput screening of the inhaled drug candidates, a further verification of cell architectures as drug transport barriers can contribute to establishing appropriate in vitro cell models. In the present study, side-by-side experiments were performed to compare the structure and transport function of three lung epithelial cells (Calu-3, normal human bronchial primary cells (NHBE), and NL-20). The cells were cultured on the nucleopore membranes in the air-liquid interface (ALI) culture conditions, with cell culture medium in the basolateral side only, starting from day 1. In transport assays, paracellular transport across all three types of cells appeared to be markedly different with the NHBE or Calu-3 cells, showing low paracellular permeability and high TEER values, while the NL-20 cells showed high paracellular permeability and low TEER. Quantitative image analysis of the confocal microscope sections further confirmed that the Calu-3 cells formed intact cell monolayers in contrast to the NHBE and NL-20 cells with multilayers. Among three lung epithelial cell types, the Calu-3 cell cultures under the ALI condition showed optimal cytometric features for mimicking the biophysical characteristics of in vivo airway epithelium. Therefore, the Calu-3 cell monolayers could be used as functional cell barriers for the lung-targeted drug transport studies.

  9. Functional and cytometric examination of different human lung epithelial cell types as drug transport barriers

    PubMed Central

    Min, Kyoung Ah; Rosania, Gus R.; Kim, Chong-Kook; Shin, Meong Cheol

    2016-01-01

    To develop inhaled medications, various cell culture models have been used to examine the transcellular transport or cellular uptake properties of small molecules. For the reproducible high throughput screening of the inhaled drug candidates, a further verification of cell architectures as drug transport barriers can contribute to establishing appropriate in vitro cell models. In the present study, side-by-side experiments were performed to compare the structure and transport function of three lung epithelial cells (Calu-3, normal human bronchial primary cells (NHBE), and NL-20). The cells were cultured on the nucleopore membranes in the air-liquid interface (ALI) culture conditions, with cell culture medium in the basolateral side only, starting from day 1. In transport assays, paracellular transport across all three types of cells appeared to be markedly different with the NHBE or Calu-3 cells, showing low paracellular permeability and high TEER values, while the NL-20 cells showed high paracellular permeability and low TEER. Quantitative image analysis of the confocal microscope sections further confirmed that the Calu-3 cells formed intact cell monolayers in contrast to the NHBE and NL-20 cells with multilayers. Among three lung epithelial cell types, the Calu-3 cell cultures under the ALI condition showed optimal cytometric features for mimicking the biophysical characteristics of in vivo airway epithelium. Therefore, the Calu-3 cell monolayers could be used as functional cell barriers for the lung-targeted drug transport studies. PMID:26746641

  10. Production of Superoxide in Bacteria Is Stress- and Cell State-Dependent: A Gating-Optimized Flow Cytometry Method that Minimizes ROS Measurement Artifacts with Fluorescent Dyes.

    PubMed

    McBee, Megan E; Chionh, Yok H; Sharaf, Mariam L; Ho, Peiying; Cai, Maggie W L; Dedon, Peter C

    2017-01-01

    The role of reactive oxygen species (ROS) in microbial metabolism and stress response has emerged as a major theme in microbiology and infectious disease. Reactive fluorescent dyes have the potential to advance the study of ROS in the complex intracellular environment, especially for high-content and high-throughput analyses. However, current dye-based approaches to measuring intracellular ROS have the potential for significant artifacts. Here, we describe a robust platform for flow cytometric quantification of ROS in bacteria using fluorescent dyes, with ROS measurements in 10s-of-1000s of individual cells under a variety of conditions. False positives and variability among sample types (e.g., bacterial species, stress conditions) are reduced with a flexible four-step gating scheme that accounts for side- and forward-scattered light (morphological changes), background fluorescence, DNA content, and dye uptake to identify cells producing ROS. Using CellROX Green dye with Escherichia coli, Mycobacterium smegmatis , and Mycobacterium bovis BCG as diverse model bacteria, we show that (1) the generation of a quantifiable CellROX Green signal for superoxide, but not hydrogen peroxide-induced hydroxyl radicals, validates this dye as a superoxide detector; (2) the level of dye-detectable superoxide does not correlate with cytotoxicity or antibiotic sensitivity; (3) the non-replicating, antibiotic tolerant state of nutrient-deprived mycobacteria is associated with high levels of superoxide; and (4) antibiotic-induced production of superoxide is idiosyncratic with regard to both the species and the physiological state of the bacteria. We also show that the gating method is applicable to other fluorescent indicator dyes, such as the 5-carboxyfluorescein diacetate acetoxymethyl ester and 5-cyano-2,3-ditolyl tetrazolium chloride for cellular esterase and reductive respiratory activities, respectively. These results demonstrate that properly controlled flow cytometry coupled

  11. Functional Renormalization Group Flows on Friedman-Lemaître-Robertson-Walker backgrounds

    NASA Astrophysics Data System (ADS)

    Platania, Alessia; Saueressig, Frank

    2018-06-01

    We revisit the construction of the gravitational functional renormalization group equation tailored to the Arnowitt-Deser-Misner formulation emphasizing its connection to the covariant formulation. The results obtained from projecting the renormalization group flow onto the Einstein-Hilbert action are reviewed in detail and we provide a novel example illustrating how the formalism may be connected to the causal dynamical triangulations approach to quantum gravity.

  12. Clinical CVVH model removes endothelium-derived microparticles from circulation

    PubMed Central

    Abdelhafeez, Abdelhafeez H.; Jeziorczak, Paul M.; Schaid, Terry R.; Hoefs, Susan L.; Kaul, Sushma; Nanchal, Rahul; Jacobs, Elizabeth R.; Densmore, John C.

    2014-01-01

    Background Endothelium-derived microparticles (EMPs) are submicron vesicles released from the plasma membrane of endothelial cells in response to injury, apoptosis or activation. We have previously demonstrated EMP-induced acute lung injury (ALI) in animal models and endothelial barrier dysfunction in vitro. Current treatment options for ALI are limited and consist of supportive therapies. We hypothesize that standard clinical continuous venovenous hemofiltration (CVVH) reduces serum EMP levels and may be adapted as a potential therapeutic intervention. Materials and methods EMPs were generated from plasminogen activation inhibitor-1 (PAI-1)-stimulated human umbilical vein endothelial cells (HUVECs). Flow cytometric analysis was used to characterize EMPs as CD31- and annexin V-positive events in a submicron size gate. Enumeration was completed against a known concentration of latex beads. Ultimately, a concentration of ~650,000 EMP/mL perfusate fluid (total 470 mL) was circulated through a standard CVVH filter (pore size 200 μm, flow rate 250 mL/hr) for a period of 70 minutes. 0.5 mL aliquots were removed at 5- to 10-minute intervals for flow cytometric analysis. EMP concentration in the dialysate was measured at the end of 4 hours to better understand the fate of EMPs. Results A progressive decrease in circulating EMP concentration was noted using standard CVVH at 250 mL/hr (a clinical standard rate) from a 470 mL volume modelling a patient's circulation. A 50% reduction was noted within the first 30 minutes. EMPs entering the dialysate after 4 hours were 5.7% of the EMP original concentration. Conclusion These data demonstrate that standard CVVH can remove EMPs from circulation in a circuit modelling a patient. An animal model of hemofiltration with induction of EMP release is required to test the therapeutic potential of this finding and potential of application in early treatment of ALI. PMID:24596654

  13. Compton scattering of the microwave background by quasar-blown bubbles

    NASA Technical Reports Server (NTRS)

    Voit, G. Mark

    1994-01-01

    At least 10% of quasars drive rapid outflows from the central regions of their host galaxies. The mass and energy flow rates in these winds are difficult to measure, but their kinetic luminosities probably exceed 10(exp 45) ergs/s. This kind of outflow easily sunders the interstellar medium of the host and blows a bubble in the intergalactic medium. After the quasar shuts off, the hot bubble continues to shock intergalactic gas until its leading edge merges with the Hubble flow. The interior hot gas Compton scatters microwave background photons, potentially providing a way to detect these bubbles. Assuming that quasar kinetic luminosities scale with their blue luminosities, we integrate over the quasar luminosity function to find the total distortion (y) of the microwave background produced by the entire population of quasar wind bubbles. This calculation of y distortion is remarkably insensitive to the properties of the intergalactic medium (IGM), quasar lifetimes, and cosmological parameters. Current Cosmic Background Explorer (COBE) limits on y constrain the kinetic luminosities of quasars to be less than several times their bolometric radiative luminosities. Within this constraint, quasars can still expel enough kinetic luminosity to shock the entire IGM by z = 0, but cannot heat and ionize the IGM by z = 4 unless omega(sub IGM) much less than 10(exp -2).

  14. Background oriented schlieren measurement of the refractive index field of air induced by a hot, cylindrical measurement object.

    PubMed

    Beermann, Rüdiger; Quentin, Lorenz; Pösch, Andreas; Reithmeier, Eduard; Kästner, Markus

    2017-05-10

    To optically capture the topography of a hot measurement object with high precision, the light deflection by the inhomogeneous refractive index field-induced by the heat transfer from the measurement object to the ambient medium-has to be considered. We used the 2D background oriented schlieren method with illuminated wavelet background, an optical flow algorithm, and Ciddor's equation to quantify the refractive index field located directly above a red-glowing, hot measurement object. A heat transfer simulation has been implemented to verify the magnitude and the shape of the measured refractive index field. Provided that no forced external flow is disturbing the shape of the convective flow originating from the hot object, a laminar flow can be observed directly above the object, resulting in a sharply bounded, inhomogeneous refractive index field.

  15. Use of internal control T-cell populations in the flow cytometric evaluation for T-cell neoplasms.

    PubMed

    Hunt, Alicia M; Shallenberger, Wendy; Ten Eyck, Stephen P; Craig, Fiona E

    2016-09-01

    Flow cytometry is an important tool for identification of neoplastic T-cells, but immunophenotypic abnormalities are often subtle and must be distinguished from nonneoplastic subsets. Use of internal control (IC) T-cells in the evaluation for T-cell neoplasms was explored, both as a quality measure and as a reference for evaluating abnormal antigen expression. All peripheral blood specimens (3-month period), or those containing abnormal T-cells (29-month period), stained with CD45 V500, CD2 V450, CD3 PE-Cy7, CD7 PE, CD4 Per-CP-Cy5.5, CD8 APC-H7, CD56 APC, CD16&57 FITC, were evaluated. IC T-cells were identified (DIVA, BD Biosciences) and median fluorescence intensity (MFI) recorded. Selected files were merged and reference templates generated (Infinicyt, Cytognos). IC T-cells were present in all specimens, including those with abnormal T-cells, but subsets were less well-represented. IC T-cell CD3 MFI differed between instruments (p = 0.0007) and subsets (p < 0.001), but not specimen categories, and served as a longitudinal process control. Merged files highlighted small unusual IC-T subsets: CD2+(dim) (0.25% total), CD2- (0.03% total). An IC reference template highlighted neoplastic T-cells, but was limited by staining variability (IC CD3 MFI reference samples different from test (p = 0.003)). IC T-cells present in the majority of specimens can serve as positive and longitudinal process controls. Use of IC T-cells as an internal reference is limited by variable representation of subsets. Analysis of merged IC T-cells from previously analyzed patient samples can alert the interpreter to less-well-recognized non-neoplastic subsets. However, application of a merged file IC reference template was limited by staining variability. © 2016 Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  16. Gastric lymphomas in Turkey. Analysis of prognostic factors with special emphasis on flow cytometric DNA content.

    PubMed

    Aydin, Z D; Barista, I; Canpinar, H; Sungur, A; Tekuzman, G

    2000-07-01

    In contrast to DNA ploidy, to the authors' knowledge the prognostic significance of S-phase fraction (SPF) in gastric lymphomas has not been determined. In the current study, the prognostic significance of various parameters including SPF and DNA aneuploidy were analyzed and some distinct epidemiologic and biologic features of gastric lymphomas in Turkey were found. A series of 78 gastric lymphoma patients followed at Hacettepe University is reported. DNA flow cytometry was performed for 34 patients. The influence of various parameters on survival was investigated with the log rank test. The Cox proportional hazards model was fitted to identify independent prognostic factors. The median age of the patients was 50 years. There was no correlation between patient age and tumor grade. DNA content analysis revealed 4 of the 34 cases to be aneuploid with DNA index values < 1.0. The mean SPF was 33.5%. In the univariate analysis, surgical resection of the tumor, modified Ann Arbor stage, performance status, response to first-line chemotherapy, lactate dehydrogenase (LDH) level, and SPF were important prognostic factors for disease free survival (DFS). The same parameters, excluding LDH level, were important for determining overall survival (OS). In the multivariate analysis, surgical resection of the tumor, disease stage, performance status, and age were found to be important prognostic factors for OS. To the authors' knowledge the current study is the first to demonstrate the prognostic significance of SPF in gastric lymphomas. The distinguishing features of Turkish gastric lymphoma patients are 1) DNA indices of aneuploid cases that all are < 1.0, which is a unique feature; 2) a lower percentage of aneuploid cases; 3) a higher SPF; 4) a younger age distribution; and 5) lack of an age-grade correlation. The authors conclude that gastric lymphomas in Turkey have distinct biologic and epidemiologic characteristics. Copyright 2000 American Cancer Society.

  17. Flow cytometric assay for analysis of cytotoxic effects of potential drugs on human peripheral blood leukocytes

    NASA Astrophysics Data System (ADS)

    Nieschke, Kathleen; Mittag, Anja; Golab, Karolina; Bocsi, Jozsef; Pierzchalski, Arkadiusz; Kamysz, Wojciech; Tarnok, Attila

    2014-03-01

    Toxicity test of new chemicals belongs to the first steps in the drug screening, using different cultured cell lines. However, primary human cells represent the human organism better than cultured tumor derived cell lines. We developed a very gentle toxicity assay for isolation and incubation of human peripheral blood leukocytes (PBL) and tested it using different bioactive oligopeptides (OP). Effects of different PBL isolation methods (red blood cell lysis; Histopaque isolation among others), different incubation tubes (e.g. FACS tubes), anticoagulants and blood sources on PBL viability were tested using propidium iodide-exclusion as viability measure (incubation time: 60 min, 36°C) and flow cytometry. Toxicity concentration and time-depended effects (10-60 min, 36 °C, 0-100 μg /ml of OP) on human PBL were analyzed. Erythrocyte lysis by hypotonic shock (dH2O) was the fastest PBL isolation method with highest viability (>85%) compared to NH4Cl-Lysis (49%). Density gradient centrifugation led to neutrophil granulocyte cell loss. Heparin anticoagulation resulted in higher viability than EDTA. Conical 1.5 mL and 2 mL micro-reaction tubes (both polypropylene (PP)) had the highest viability (99% and 97%) compared to other tubes, i.e. three types of 5.0 mL round-bottom tubes PP (opaque-60%), PP (blue-62%), Polystyrene (PS-64%). Viability of PBL did not differ between venous and capillary blood. A gentle reproducible preparation and analytical toxicity-assay for human PBL was developed and evaluated. Using our assay toxicity, time-course, dose-dependence and aggregate formation by OP could be clearly differentiated and quantified. This novel assay enables for rapid and cost effective multiparametric toxicological screening and pharmacological testing on primary human PBL and can be adapted to high-throughput-screening.°z

  18. Flow-cytometric determination of genotoxic effects of exposure to petroleum in mink and sea otters

    USGS Publications Warehouse

    Bickham, J.W.; Mazet, J.A.; Blake, J.; Smolen, M.J.; Lou, Y.; Ballachey, Brenda E.

    1998-01-01

    Three experiments were conducted to investigate the genotoxic effects of crude oil on mink and sea otters, In the first experiment, the effects on mink of chronic exposure to weathered Prudhoe Bay crude oil were studied, Female mink were fed a diet that included weathered crude oil for a period of 3 weeks prior to mating, during pregnancy and until weaning. Kits were exposed through lactation and by diet after weaning until 4 months of age. Kidney and liver tissues of the kits were examined using flow cytometry (FCM) and it was found that the genome size was increased in kidney samples from the experimental group compared to the control group. This effect was probably due to some type of DNA amplification and it could have been inherited from the exposed mothers or have been a somatic response to oil exposure in the pups, No evidence of clastogenic effects, as measured by the coefficient of variation (CV) of the G(1) peak, was found in kidney or liver tissue. In the second experiment, yearling female mink were exposed either by diet or externally to crude oil or bunker C fuel oil. Evidence for clastogenic damage was found in spleen tissue for the exposure groups, but not in kidney tissue. No evidence of increased genome size was observed. In the third experiment, blood was obtained from wild-caught sea otters in Prince William Sound. The sea otters represented two populations: one from western Prince William Sound that was potentially exposed to oil from the Exxon Valdez oil spill and a reference population from eastern Prince William Sound that did not receive oil from the spill. The spill had occurred 1.5 years prior to obtaining the blood samples. Although the mean CVs did not differ between the populations, the exposed population had a significantly higher variance of CV measurements and five out of 15 animals from the exposed population had CVs higher than the 95% confidence limits of the reference population, It is concluded that FCM is a sensitive indicator

  19. Flow cytometric monitoring of bacterioplankton phenotypic diversity predicts high population-specific feeding rates by invasive dreissenid mussels.

    PubMed

    Props, Ruben; Schmidt, Marian L; Heyse, Jasmine; Vanderploeg, Henry A; Boon, Nico; Denef, Vincent J

    2018-02-01

    Species invasion is an important disturbance to ecosystems worldwide, yet knowledge about the impacts of invasive species on bacterial communities remains sparse. Using a novel approach, we simultaneously detected phenotypic and derived taxonomic change in a natural bacterioplankton community when subjected to feeding pressure by quagga mussels, a widespread aquatic invasive species. We detected a significant decrease in diversity within 1 h of feeding and a total diversity loss of 11.6 ± 4.1% after 3 h. This loss of microbial diversity was caused by the selective removal of high nucleic acid populations (29 ± 5% after 3 h). We were able to track the community diversity at high temporal resolution by calculating phenotypic diversity estimates from flow cytometry (FCM) data of minute amounts of sample. Through parallel FCM and 16S rRNA gene amplicon sequencing analysis of environments spanning a broad diversity range, we showed that the two approaches resulted in highly correlated diversity measures and captured the same seasonal and lake-specific patterns in community composition. Based on our results, we predict that selective feeding by invasive dreissenid mussels directly impacts the microbial component of the carbon cycle, as it may drive bacterioplankton communities toward less diverse and potentially less productive states. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  20. Background-Oriented Schlieren used in a hypersonic inlet test at NASA GRC

    NASA Technical Reports Server (NTRS)

    Clem, Michelle; Woike, Mark; Saunders, John

    2016-01-01

    Background Oriented Schlieren (BOS) is a derivative of the classical schlieren technology, which is used to visualize density gradients, such as shock wave structures in a wind tunnel. Changes in refractive index resulting from density gradients cause light rays to bend, resulting in apparent motion of a random background pattern. The apparent motion of the pattern is determined using cross-correlation algorithms (between no-flow and with-flow image pairs) producing a schlieren-like image. One advantage of BOS is its simplified setup which enables a larger field-of-view (FOV) than traditional schlieren systems. In the present study, BOS was implemented into the Combined Cycle Engine Large-Scale Inlet Mode Transition Experiment (CCE LIMX) in the 10x10 Supersonic Wind Tunnel at NASA Glenn Research Center. The model hardware for the CCE LIMX accommodates a fully integrated turbine based combined cycle propulsion system. To date, inlet mode transition between turbine and ramjet operation has been successfully demonstrated. High-speed BOS was used to visualize the behavior of the flow structures shock waves during unsteady inlet unstarts, a phenomenon known as buzz. Transient video images of inlet buzz were recorded for both the ramjet flow path (high speed inlet) and turbine flow path (low speed inlet). To understand the stability limits of the inlet, operation was pushed to the point of unstart and buzz. BOS was implemented in order to view both inlets simultaneously, since the required FOV was beyond the capability of the current traditional schlieren system. An example of BOS data (Images 1-6) capturing inlet buzz are presented.

  1. Search for the Chiral Magnetic Effect in Heavy-Ion Collisions and Quantification of the Background with the AMPT Model

    NASA Astrophysics Data System (ADS)

    Bryon, Jacob

    2017-09-01

    The chiral magnetic effect (CME) arises from the chirality imbalance of quarks and its interaction to the strong magnetic field generated in non-central heavy-ion collisions. Possible formation of domains of quarks with chirality imbalances is an intrinsic property of the Quantum ChromoDynamics (QCD), which describes the fundamental strong interactions among quarks and gluons. Azimuthal-angle correlations have been used to measure the magnitude of charge- separation across the reaction plane, which was predicted to arise from the CME. However, backgrounds from collective motion (flow) of the collision system can also contribute to the correlation observable. In this poster, we investigate the magnitude of the background utilizing the AMPT model, which contains no CME signals. We demonstrate, for Au +Au collisions at 200 and 39 GeV, a scheme to remove the flow background via the event-shape engineering with the vanishing magnitude of the flow vector. We also calculate the ensemble average of the charge-separation observable, and provide a background baseline for the experimental data.

  2. Analysis of the clinical backgrounds of patients who developed respiratory acidosis under high-flow oxygen therapy during emergency transport.

    PubMed

    Ogino, Hirokazu; Nishimura, Naoki; Yamano, Yasuhiko; Ishikawa, Genta; Tomishima, Yutaka; Jinta, Torahiko; Takahashi, Osamu; Chohnabayashi, Naohiko

    2016-01-01

    High-flow oxygen is often administered to patients during emergency transport and can sometimes cause respiratory acidosis with disturbed consciousness, thereby necessitating mechanical ventilation. Although oxygen titration in chronic obstructive pulmonary disease patients during emergency transport reduces mortality rates, the clinical risk factors for respiratory acidosis in emergency settings are not fully understood. Therefore, we analyzed the clinical backgrounds of patients who developed respiratory acidosis during pre-hospital transport. This was a retrospective study of patients who arrived at our hospital by emergency transport in 2010 who received high-flow oxygen while in transit. Respiratory acidosis was defined by the following arterial blood gas readings: pH, ≤7.35; PaCO 2 , ≥45 mmHg; and HCO 3 - , ≥24 mmol/L. The risk factors were identified using multivariable logistic regression analysis. In 765 study patients, 66 patients showed respiratory acidosis. The following risk factors for respiratory acidosis were identified: age, ≥65 years (odds ratio [OR] 1.4; 95% confidence interval [CI], 0.7-2.8); transportation time, ≥10 min (OR 2.0; 95% CI, 1.1-3.7); three digits on the Japan Coma Scale (OR 3.1; 95% CI, 1.7-5.8); percutaneous oxygen saturation, ≤90% (OR 1.6; 95% CI, 0.8-3.0); tuberculosis (OR 4.5; 95% CI, 1.4-15.1); asthma (OR 1.8; 95% CI, 0.6-5.3); pneumonia (OR 1.5; 95% CI, 0.7-3.1); and lung cancer (OR 3.9; 95% CI, 1.5-10.1). These underlying diseases as risk factors included both comorbid diseases and past medical conditions. The factors identified may contribute to the development of respiratory acidosis. Further studies on preventing respiratory acidosis will improve the quality of emergency medical care.

  3. Flow Cytometric Panel-Reactive Antibody Results and the Ability to Find Transfusion-Compatible Platelets after Antibody-Desensitization for Allogeneic Bone Marrow Transplant.

    PubMed

    Rosenbaum, Eric R; Pandey, Soumya; Harville, Terry O; Drobena, Gina A; Cottler-Fox, Michele

    2016-12-01

    Panel reactive antibody (PRA) reduction protocols are used to decrease anti-HLA antibodies with concomitant PRA monitoring as a measure of successful treatment prior to organ and haploidentical blood and marrow transplant (BMT). We hypothesized that the more sensitive flow cytometry (FC) based assays for PRA [FlowPRA ® and Luminex ® based Single Antigen Bead (SAB)] would also correlate with the ability to find compatible platelets for allosensitized recipients. A female patient with myelodysplastic syndrome and a high HLA class I PRA [>90% PRA and cPRA by complement-dependent cytotoxicity (CDC) assay and Flow PRA] required allogeneic BMT. Baseline HLA Class I and class II antigen typing was performed and a matched sibling donor was identified. Although baseline anti-HLA class I and class II antibodies measured by FC and CDC revealed no donor specific antibodies (DSA), the decision was made to attempt antibody desensitization to facilitate platelet transfusion during BMT. FC and CDC assays were performed to determine anti-HLA class I antibodies and cPRA/%PRA prior to starting desensitization and at the end of desensitization. Over the course of desensitization and BMT, a total of 194 apheresis platelet units underwent cross-match (XM) using Capture-P ® . We compared temporally-related PRA results with platelet XM results. High PRA by FC or CDC assays correlates with a high % of XM-positive (incompatible) platelet units. When the CDC PRA fell to 2% after desensitization, platelet XM incompatibility fell from 100% to 63% positive (incompatible). When the FC PRA fell to 5% the positive platelet XM fell to 5%. Antibody desensitization facilitated platelet transfusion. PRA determination by FC appeared better correlated than determination by CDC with the ability to find XM-compatible platelets. © 2016 by the Association of Clinical Scientists, Inc.

  4. Annual Progress Report FY-92. Volume 1

    DTIC Science & Technology

    1993-01-21

    Billups, L Flow Cytom Resh Psychologist 12 0180 CS Hamm, C DCI 7 DESCRIPTION GRADE MOS BRANCH NAME ACTIVITY Kyle Metabolic Unit Nursing Service Supv...3349 Salata, Kalman PhD. Mitogen-Inducible T Suppressor Cell 13 Assay by Flow Cytometry (12/89) 3350 Salata, Kalman PhD. Flow Cytometric Analysis of...17 Immunotherapy (3/90) 3354 Salata, Kalman PhD. Two Way Mixed Lymphocyte Culture: 18 Analysis by Two Color Flow Cytometry (4/90) 3355 Salata, Kalman

  5. Apparatus for eliminating background interference in fluorescence measurements

    DOEpatents

    Martin, J.C.; Jett, J.H.

    1984-01-06

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser which excites a different stained component of the same biological particle.

  6. Apparatus for eliminating background interference in fluorescence measurements

    DOEpatents

    Martin, John C.; Jett, James H.

    1986-01-01

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle.

  7. Apparatus for eliminating background interference in fluorescence measurements

    DOEpatents

    Martin, J.C.; Jett, J.H.

    1986-03-04

    The disclosure is directed to an apparatus for eliminating background interference during fluorescence measurements in a multiple laser flow cytometer. A biological particle stained with fluorescent dyes is excited by a laser. A fluorescence detector detects the fluorescence. The particle scatters light and a gate signal is generated and delayed until the biological particle reaches the next laser. The delayed signal turns on this next laser, which excites a different stained component of the same biological particle. 8 figs.

  8. Method for screening inhibitors of the toxicity of Bacillus anthracis

    DOEpatents

    Cirino, Nick M.; Jackson, Paul J.; Lehnert, Bruce E.

    2001-01-01

    The protective antigen (PA) of Bacillus anthracis is integral to the mechanism of anthrax poisoning. The cloning, expression and purification of a 32 kDa B. anthracis PA fragment (PA32) is described. This fragment has also been expressed as a fusion construct to stabilized green fluorescent protein (EGFP-PA32). Both proteins were capable of binding to specific cell surface receptors as determined by fluorescent microscopy and a flow cytometric assay. To confirm binding specificity in the flow cytometric assay, non-fluorescent PA83 or PA32 was used to competitively inhibit fluorescent EGFP-PA32 binding to cell receptors. This assay can be employed as a rapid screen for compounds which disrupts binding of PA to cells. Additionally, the high intracellular expression levels and ease of purification make this recombinant protein an attractive vaccine candidate or therapeutic treatment for anthrax poisoning.

  9. Whole Blood Activation Results in Enhanced Detection of T Cell and Monocyte Cytokine Production by Flow Cytometry

    NASA Technical Reports Server (NTRS)

    Sams, Clarence F.; Crucian, Brian E.

    2001-01-01

    An excellent monitor of the immune balance of peripheral circulating cells is to determine their cytokine production patterns in response to stimuli. Using flow cytometry a positive identification of cytokine producing cells in a mixed culture may be achieved. Recently, the ability to assess cytokine production following a wholeblood activation culture has been described. We compared whole blood culture to standard PBMC culture and determined the individual cytokine secretion patterns for both T cells and monocytes via flow cytometry. For T cells cytokine assessment following PMA +ionomycin activation: (1) a significantly greater percentages of T cells producing IFNgamma and IL-2 were observed following whole-blood culture; (2) altered T cell cytokine production kinetics were observed by varying whole blood culture times. In addition, a four-color cytometric analysis was used to allow accurate phenotyping and quantitation of cytokine producing lymphocyte populations. Using this technique we found IFNgamma production to be significantly elevated in the CD3+/CD8+ T cell population as compared to the CD3+/CD8- population following five hours of whole blood activation. Conversely, IL-2 and IL-10 production were significantly elevated in the CD3+/CD8- T cell population as compared to the CD3+/CD8+ population. Monocyte cytokine production was assessed in both culture systems following LPS activation for 24 hours. A three-color flow cytometric was used to assess two cytokines in conjunction with CD 14. The cytokine pairs used for analysis were IL-1a/IL-12, and IL-10ITNFa. Nearly all monocytes were stimulated to produce IL-1a, IL-12 and TNFalpha equally well in both culture systems. Monocyte production of IL-10 was significantly elevated following whole blood culture as compared to PBMC culture. IL-12 producing monocytes appeared to be a distinct subpopulation of the IL-1a producing set, whereas IL-10 and TNFa producing monocytes were largely mutually exclusive. IL-10 and

  10. Shifts in the fluorescence lifetime of EGFP during bacterial phagocytosis measured by phase-sensitive flow cytometry

    NASA Astrophysics Data System (ADS)

    Li, Wenyan; Houston, Kevin D.; Houston, Jessica P.

    2017-01-01

    Phase-sensitive flow cytometry (PSFC) is a technique in which fluorescence excited state decay times are measured as fluorescently labeled cells rapidly transit a finely focused, frequency-modulated laser beam. With PSFC the fluorescence lifetime is taken as a cytometric parameter to differentiate intracellular events that are challenging to distinguish with standard flow cytometry. For example PSFC can report changes in protein conformation, expression, interactions, and movement, as well as differences in intracellular microenvironments. This contribution focuses on the latter case by taking PSFC measurements of macrophage cells when inoculated with enhanced green fluorescent protein (EGFP)-expressing E. coli. During progressive internalization of EGFP-E. coli, fluorescence lifetimes were acquired and compared to control groups. It was hypothesized that fluorescence lifetimes would correlate well with phagocytosis because phagosomes become acidified and the average fluorescence lifetime of EGFP is known to be affected by pH. We confirmed that average EGFP lifetimes consistently decreased (3 to 2 ns) with inoculation time. The broad significance of this work is the demonstration of how high-throughput fluorescence lifetime measurements correlate well to changes that are not easily tracked by intensity-only cytometry, which is affected by heterogeneous protein expression, cell-to-cell differences in phagosome formation, and number of bacterium engulfed.

  11. Lunar ash flows - Isothermal approximation.

    NASA Technical Reports Server (NTRS)

    Pai, S. I.; Hsieh, T.; O'Keefe, J. A.

    1972-01-01

    Suggestion of the ash flow mechanism as one of the major processes required to account for some features of lunar soil. First the observational background and the gardening hypothesis are reviewed, and the shortcomings of the gardening hypothesis are shown. Then a general description of the lunar ash flow is given, and a simple mathematical model of the isothermal lunar ash flow is worked out with numerical examples to show the differences between the lunar and the terrestrial ash flow. The important parameters of the ash flow process are isolated and analyzed. It appears that the lunar surface layer in the maria is not a residual mantle rock (regolith) but a series of ash flows due, at least in part, to great meteorite impacts. The possibility of a volcanic contribution is not excluded. Some further analytic research on lunar ash flows is recommended.

  12. Automatic cytometric device using multiple wavelength excitations

    NASA Astrophysics Data System (ADS)

    Rongeat, Nelly; Ledroit, Sylvain; Chauvet, Laurence; Cremien, Didier; Urankar, Alexandra; Couderc, Vincent; Nérin, Philippe

    2011-05-01

    Precise identification of eosinophils, basophils, and specific subpopulations of blood cells (B lymphocytes) in an unconventional automatic hematology analyzer is demonstrated. Our specific apparatus mixes two excitation radiations by means of an acousto-optics tunable filter to properly control fluorescence emission of phycoerythrin cyanin 5 (PC5) conjugated to antibodies (anti-CD20 or anti-CRTH2) and Thiazole Orange. This way our analyzer combining techniques of hematology analysis and flow cytometry based on multiple fluorescence detection, drastically improves the signal to noise ratio and decreases the spectral overlaps impact coming from multiple fluorescence emissions.

  13. Novel full-spectral flow cytometry with multiple spectrally-adjacent fluorescent proteins and fluorochromes and visualization of in vivo cellular movement.

    PubMed

    Futamura, Koji; Sekino, Masashi; Hata, Akihiro; Ikebuchi, Ryoyo; Nakanishi, Yasutaka; Egawa, Gyohei; Kabashima, Kenji; Watanabe, Takeshi; Furuki, Motohiro; Tomura, Michio

    2015-09-01

    Flow cytometric analysis with multicolor fluoroprobes is an essential method for detecting biological signatures of cells. Here, we present a new full-spectral flow cytometer (spectral-FCM). Unlike conventional flow cytometer, this spectral-FCM acquires the emitted fluorescence for all probes across the full-spectrum from each cell with 32 channels sequential PMT unit after dispersion with prism, and extracts the signals of each fluoroprobe based on the spectral shape of each fluoroprobe using unique algorithm in high speed, high sensitive, accurate, automatic and real-time. The spectral-FCM detects the continuous changes in emission spectra from green to red of the photoconvertible protein, KikGR with high-spectral resolution and separates spectrally-adjacent fluoroprobes, such as FITC (Emission peak (Em) 519 nm) and EGFP (Em 507 nm). Moreover, the spectral-FCM can measure and subtract autofluorescence of each cell providing increased signal-to-noise ratios and improved resolution of dim samples, which leads to a transformative technology for investigation of single cell state and function. These advances make it possible to perform 11-color fluorescence analysis to visualize movement of multilinage immune cells by using KikGR-expressing mice. Thus, the novel spectral flow cytometry improves the combinational use of spectrally-adjacent various FPs and multicolor fluorochromes in metabolically active cell for the investigation of not only the immune system but also other research and clinical fields of use. © 2015 International Society for Advancement of Cytometry.

  14. Flow cytometry and cell sorting of heterogeneous microbial populations: the importance of single-cell analyses.

    PubMed Central

    Davey, H M; Kell, D B

    1996-01-01

    The most fundamental questions such as whether a cell is alive, in the sense of being able to divide or to form a colony, may sometimes be very hard to answer, since even axenic microbial cultures are extremely heterogeneous. Analyses that seek to correlate such things as viability, which is a property of an individual cell, with macroscopic measurements of culture variables such as ATP content, respiratory activity, and so on, must inevitably fail. It is therefore necessary to make physiological measurements on individual cells. Flow cytometry is such a technique, which allows one to analyze cells rapidly and individually and permits the quantitative analysis of microbial heterogeneity. It therefore offers many advantages over conventional measurements for both routine and more exploratory analyses of microbial properties. While the technique has been widely applied to the study of mammalian cells, is use in microbiology has until recently been much more limited, largely because of the smaller size of microbes and the consequently smaller optical signals obtainable from them. Since these technical barriers no longer hold, flow cytometry with appropriate stains has been used for the rapid discrimination and identification of microbial cells, for the rapid assessment of viability and of the heterogeneous distributions of a wealth of other more detailed physiological properties, for the analysis of antimicrobial drug-cell interactions, and for the isolation of high-yielding strains of biotechnological interest. Flow cytometric analyses provide an abundance of multivariate data, and special methods have been devised to exploit these. Ongoing advances mean that modern flow cytometers may now be used by nonspecialists to effect a renaissance in our understanding of microbial heterogeneity. PMID:8987359

  15. Reciprocating free-flow isoelectric focusing device for preparative separation of proteins.

    PubMed

    Kong, Fan-Zhi; Yang, Ying; Wang, Yi; Li, Guo-Qing; Li, Shan; Xiao, Hua; Fan, Liu-Yin; Liu, Shao-Rong; Cao, Cheng-Xi

    2015-11-27

    The traditional recycling free-flow isoelectric focusing (RFFIEF) suffered from complex structure, tedious operations and poor extensibility as well as high cost. To address these issues, a novel reciprocating free-flow isoelectric focusing device (ReFFIEF) was developed for proteins or peptides pre-fractionation. In the new device, a reciprocating background flow was for the first time introduced into free flow electrophoresis (FFE) system. The gas cushion injector (GCI) used in the previous continuous free-flow electrophoresis (CFFE) was redesigned for the reciprocating background flow. With the GCI, the reciprocating background flow could be achieved between the GCI, separation chamber and transient self-balance collector (tSBC). In a run, process fluid flowed to and from, forming a stable reciprocating fluid flow in the separation chamber. A pH gradient was created within the separation chamber, and at the same time proteins were focused repeatedly when passing through the chamber under perpendicular electric field. The ReFFIEF procedure was optimized for fractionations of three model proteins, and the optimized method was further used for pre-fractionation of model human serum samples. As compared with the traditional RFFIEF devices developed about 25 years ago, the new ReFFIEF system showed several merits, such as simple design and structure, user-friendly operation and easy to extend as well as low cost. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Interference of blood leucocytes in the measurements of immature red cells (reticulocytes) by two different (semi-) automated flow-cytometry technologies.

    PubMed

    Villamor, N; Kirsch, A; Huhn, D; Vives-Corrons, J L; Serke, S

    1996-06-01

    Flow cytometrical methods have been introduced recently as an alternative to the enumeration of reticulocytes by microscopy. Two of these methods have gained widespread use in haematological practice; the multiparametric flow cytometer using thiazole orange staining (Retic-Count, FACScan) and the single-application reticulocyte counter using auramine-O staining (R-series, Sysmex). Several studies have emphasized the excellent correlations between microscopy and these techniques. The purpose of our study has been to examine the specificity of these automated devices with regard to cells classified as 'reticulocytes' and the effect that this may have on measures of reticulocyte maturity. Our results indicate that the specificity of reticulocyte measurements by both the Sysmex R-1000/-3000 and the Retic-Count system is relatively low. This is due to the presence of leucocytes amongst cells classified as reticulocytes. These leucocytes display intense staining with either dye, leading to an erroneous estimation of RMI (thiazole orange) and high fluorescence count (R-1000/-3000). This error is directly correlated with the leucocyte count. The basis for reticulocyte identification should be improved before automated estimation of reticulocyte maturation can be used in clinical practice.

  17. Cytometric comparisons between circulating tumor cells from prostate cancer patients and the prostate-tumor-derived LNCaP cell line

    NASA Astrophysics Data System (ADS)

    Lazar, Daniel C.; Cho, Edward H.; Luttgen, Madelyn S.; Metzner, Thomas J.; Loressa Uson, Maria; Torrey, Melissa; Gross, Mitchell E.; Kuhn, Peter

    2012-02-01

    Many important experiments in cancer research are initiated with cell line data analysis due to the ease of accessibility and utilization. Recently, the ability to capture and characterize circulating tumor cells (CTCs) has become more prevalent in the research setting. This ability to detect, isolate and analyze CTCs allows us to directly compare specific protein expression levels found in patient CTCs to cell lines. In this study, we use immunocytochemistry to compare the protein expression levels of total cytokeratin (CK) and androgen receptor (AR) in CTCs and cell lines from patients with prostate cancer to determine what translational insights might be gained through the use of cell line data. A non-enrichment CTC detection assay enables us to compare cytometric features and relative expression levels of CK and AR by indirect immunofluorescence from prostate cancer patients against the prostate cancer cell line LNCaP. We measured physical characteristics of these two groups and observed significant differences in cell size, fluorescence intensity and nuclear to cytoplasmic ratio. We hope that these experiments will initiate a foundation to allow cell line data to be compared against characteristics of primary cells from patients.

  18. Background nuclei measurements and implications for cavitation inception in hydrodynamic test facilities

    NASA Astrophysics Data System (ADS)

    Venning, J. A.; Khoo, M. T.; Pearce, B. W.; Brandner, P. A.

    2018-04-01

    Water susceptibility and background nuclei content in a water tunnel are investigated using a cavitation susceptibility meter. The measured cumulative histogram of nuclei concentration against critical pressure shows a power law dependence over a large range of concentrations and pressures. These results show that the water strength is not characterised by a single tension but is susceptible to `all' tensions depending on the relevant timescale. This background nuclei population is invariant to tunnel conditions showing that it is stabilised against dissolution. Consideration of a practical cavitating flow about a sphere shows that although background nuclei may be activated, their numbers are so few compared with other sources that they are insignificant for this case.

  19. Background oriented schlieren in a density stratified fluid.

    PubMed

    Verso, Lilly; Liberzon, Alex

    2015-10-01

    Non-intrusive quantitative fluid density measurement methods are essential in the stratified flow experiments. Digital imaging leads to synthetic schlieren methods in which the variations of the index of refraction are reconstructed computationally. In this study, an extension to one of these methods, called background oriented schlieren, is proposed. The extension enables an accurate reconstruction of the density field in stratified liquid experiments. Typically, the experiments are performed by the light source, background pattern, and the camera positioned on the opposite sides of a transparent vessel. The multimedia imaging through air-glass-water-glass-air leads to an additional aberration that destroys the reconstruction. A two-step calibration and image remapping transform are the key components that correct the images through the stratified media and provide a non-intrusive full-field density measurements of transparent liquids.

  20. What Do University Endowment Managers Worry About? An Analysis of Alternative Asset Investments and Background Income

    ERIC Educational Resources Information Center

    Rosen, Harvey S.; Sappington, Alexander J. W.

    2016-01-01

    This paper examines whether university endowment managers think only in terms of the assets they manage or also take into account background income, that is, the other flows of income to the university. Specifically, we test whether the level and variability of a university's background income (e.g., from tuition and government grants) affect its…

  1. Magnetothermal instability in cooling flows

    NASA Technical Reports Server (NTRS)

    Loewenstein, Michael

    1990-01-01

    The effect of magnetic fields on thermal instability in cooling flows is investigated using linear, Eulerian perturbation analysis. As contrasted with the zero magnetic-field case, hydromagnetic stresses support perturbations against acceleration caused by buoyancy - comoving evolution results and global growth rates are straightforward to obtain for a given cooling flow entropy distribution. In addition, background and induced magnetic fields ensure that conductive damping of thermal instability is greatly reduced.

  2. Flow cytometric analysis reveals the high levels of platelet activation parameters in circulation of multiple sclerosis patients.

    PubMed

    Morel, Agnieszka; Rywaniak, Joanna; Bijak, Michał; Miller, Elżbieta; Niwald, Marta; Saluk, Joanna

    2017-06-01

    The epidemiological studies confirm an increased risk of cardiovascular disease in multiple sclerosis, especially prothrombotic events directly associated with abnormal platelet activity. The aim of our study was to investigate the level of blood platelet activation in the circulation of patients with chronic phase of multiple sclerosis (SP MS) and their reactivity in response to typical platelets' physiological agonists. We examined 85 SP MS patients diagnosed according to the revised McDonald's criteria and 50 healthy volunteers as a control group. The platelet activation and reactivity were assessed using flow cytometry analysis of the following: P-selectin expression (CD62P), activation of GP IIb/IIIa complex (PAC-1 binding), and formation of platelet microparticles (PMPs) and platelet aggregates (PA) in agonist-stimulated (ADP, collagen) and unstimulated whole blood samples. Furthermore, we measured the level of soluble P-selectin (sP-selectin) in plasma using ELISA method, to evaluate the in vivo level of platelet activation, both in healthy and SP MS subjects. We found a statistically significant increase in P-selectin expression, GP IIb/IIIa activation, and formation of PMPs and PA, as well as in unstimulated and agonist-stimulated (ADP, collagen) platelets in whole blood samples from patients with SP MS in comparison to the control group. We also determined the higher sP-selectin level in plasma of SP MS subjects than in the control group. Based on the obtained results, we might conclude that during the course of SP MS platelets are chronically activated and display hyperreactivity to physiological agonists, such as ADP or collagen.

  3. Flow cytometry for intracellular SPION quantification: specificity and sensitivity in comparison with spectroscopic methods

    PubMed Central

    Friedrich, Ralf P; Janko, Christina; Poettler, Marina; Tripal, Philipp; Zaloga, Jan; Cicha, Iwona; Dürr, Stephan; Nowak, Johannes; Odenbach, Stefan; Slabu, Ioana; Liebl, Maik; Trahms, Lutz; Stapf, Marcus; Hilger, Ingrid; Lyer, Stefan; Alexiou, Christoph

    2015-01-01

    Due to their special physicochemical properties, iron nanoparticles offer new promising possibilities for biomedical applications. For bench to bedside translation of super-paramagnetic iron oxide nanoparticles (SPIONs), safety issues have to be comprehensively clarified. To understand concentration-dependent nanoparticle-mediated toxicity, the exact quantification of intracellular SPIONs by reliable methods is of great importance. In the present study, we compared three different SPION quantification methods (ultraviolet spectrophotometry, magnetic particle spectroscopy, atomic adsorption spectroscopy) and discussed the shortcomings and advantages of each method. Moreover, we used those results to evaluate the possibility to use flow cytometric technique to determine the cellular SPION content. For this purpose, we correlated the side scatter data received from flow cytometry with the actual cellular SPION amount. We showed that flow cytometry provides a rapid and reliable method to assess the cellular SPION content. Our data also demonstrate that internalization of iron oxide nanoparticles in human umbilical vein endothelial cells is strongly dependent to the SPION type and results in a dose-dependent increase of toxicity. Thus, treatment with lauric acid-coated SPIONs (SEONLA) resulted in a significant increase in the intensity of side scatter and toxicity, whereas SEONLA with an additional protein corona formed by bovine serum albumin (SEONLA-BSA) and commercially available Rienso® particles showed only a minimal increase in both side scatter intensity and cellular toxicity. The increase in side scatter was in accordance with the measurements for SPION content by the atomic adsorption spectroscopy reference method. In summary, our data show that flow cytometry analysis can be used for estimation of uptake of SPIONs by mammalian cells and provides a fast tool for scientists to evaluate the safety of nanoparticle products. PMID:26170658

  4. Focusing of active particles in a converging flow

    DOE PAGES

    Potomkin, Mykhailo; Kaiser, Andreas; Berlyand, Leonid; ...

    2017-10-20

    We consider active particles swimming in a convergent fluid flow in a trapezoid nozzle with no-slip walls. We use mathematical modeling to analyze trajectories of these particles inside the nozzle. By extensive Monte Carlo simulations, we show that trajectories are strongly affected by the background fluid flow and geometry of the nozzle leading to wall accumulation and upstream motion (rheotaxis). In particular, we describe the non-trivial focusing of active rods depending on physical and geometrical parameters. It is also established that the convergent component of the background flow leads to stability of both downstream and upstream swimming at the centerline.more » The stability of downstream swimming enhances focusing, and the stability of upstream swimming enables rheotaxis in the bulk.« less

  5. A critical review of published methods for analysis of red cell antigen-antibody reactions by flow cytometry, and approaches for resolving problems with red cell agglutination.

    PubMed

    Arndt, Patricia A; Garratty, George

    2010-07-01

    Flow cytometry operators often apply familiar white blood cell (WBC) methods when studying red blood cell (RBC) antigens and antibodies. Some WBC methods are not appropriate for RBCs, as the analysis of RBCs requires special considerations, for example, avoidance of agglutination. One hundred seventy-six published articles from 88 groups studying RBC interactions were reviewed. Three fourths of groups used at least one unnecessary WBC procedure for RBCs, and about one fourth did not use any method to prevent/disperse RBC agglutination. Flow cytometric studies were performed to determine the effect of RBC agglutination on results and compare different methods of preventing and/or dispersing agglutination. The presence of RBC agglutinates have been shown to be affected by the type of pipette tip used for mixing RBC suspensions, the number of antigen sites/RBC, the type and concentration of primary antibody, and the type of secondary antibody. For quantitation methods, for example, fetal maternal hemorrhage, the presence of agglutinates have been shown to adversely affect results (fewer fetal D+ RBCs detected). Copyright 2010 Elsevier Inc. All rights reserved.

  6. Method and apparatus for acoustically monitoring the flow of suspended solid particulate matter

    DOEpatents

    Roach, Paul D.; Raptis, Apostolos C.

    1982-01-01

    A method and apparatus for monitoring char flow in a coal gasifier system cludes flow monitor circuits which measure acoustic attenuation caused by the presence of char in a char line and provide a char flow/no flow indication and an indication of relative char density. The flow monitor circuits compute the ratio of signals in two frequency bands, a first frequency band representative of background noise, and a second higher frequency band in which background noise is attenuated by the presence of char. Since the second frequency band contains higher frequencies, the ratio can be used to provide a flow/no flow indication. The second band can also be selected so that attenuation is monotonically related to particle concentration, providing a quantitative measure of char concentration.

  7. Strong wave/mean-flow coupling in baroclinic acoustic streaming

    NASA Astrophysics Data System (ADS)

    Chini, Greg; Michel, Guillaume

    2017-11-01

    Recently, Chini et al. demonstrated the potential for large-amplitude acoustic streaming in compressible channel flows subjected to strong background cross-channel density variations. In contrast with classic Rayleigh streaming, standing acoustic waves of O (ɛ) amplitude acquire vorticity owing to baroclinic torques acting throughout the domain rather than via viscous torques acting in Stokes boundary layers. More significantly, these baroclinically-driven streaming flows have a magnitude that also is O (ɛ) , i.e. comparable to that of the sound waves. In the present study, the consequent potential for fully two-way coupling between the waves and streaming flows is investigated using a novel WKBJ analysis. The analysis confirms that the wave-driven streaming flows are sufficiently strong to modify the background density gradient, thereby modifying the leading-order acoustic wave structure. Simulations of the wave/mean-flow system enabled by the WKBJ analysis are performed to illustrate the nature of the two-way coupling, which contrasts sharply with classic Rayleigh streaming, for which the waves can first be determined and the streaming flows subsequently computed.

  8. Analysis of the clinical backgrounds of patients who developed respiratory acidosis under high‐flow oxygen therapy during emergency transport

    PubMed Central

    Ogino, Hirokazu; Yamano, Yasuhiko; Ishikawa, Genta; Tomishima, Yutaka; Jinta, Torahiko; Takahashi, Osamu; Chohnabayashi, Naohiko

    2015-01-01

    Aim High‐flow oxygen is often administered to patients during emergency transport and can sometimes cause respiratory acidosis with disturbed consciousness, thereby necessitating mechanical ventilation. Although oxygen titration in chronic obstructive pulmonary disease patients during emergency transport reduces mortality rates, the clinical risk factors for respiratory acidosis in emergency settings are not fully understood. Therefore, we analyzed the clinical backgrounds of patients who developed respiratory acidosis during pre‐hospital transport. Methods This was a retrospective study of patients who arrived at our hospital by emergency transport in 2010 who received high‐flow oxygen while in transit. Respiratory acidosis was defined by the following arterial blood gas readings: pH, ≤7.35; PaCO 2, ≥45 mmHg; and HCO 3 −, ≥24 mmol/L. The risk factors were identified using multivariable logistic regression analysis. Results In 765 study patients, 66 patients showed respiratory acidosis. The following risk factors for respiratory acidosis were identified: age, ≥65 years (odds ratio [OR] 1.4; 95% confidence interval [CI], 0.7–2.8); transportation time, ≥10 min (OR 2.0; 95% CI, 1.1–3.7); three digits on the Japan Coma Scale (OR 3.1; 95% CI, 1.7–5.8); percutaneous oxygen saturation, ≤90% (OR 1.6; 95% CI, 0.8–3.0); tuberculosis (OR 4.5; 95% CI, 1.4–15.1); asthma (OR 1.8; 95% CI, 0.6–5.3); pneumonia (OR 1.5; 95% CI, 0.7–3.1); and lung cancer (OR 3.9; 95% CI, 1.5–10.1). These underlying diseases as risk factors included both comorbid diseases and past medical conditions. Conclusions The factors identified may contribute to the development of respiratory acidosis. Further studies on preventing respiratory acidosis will improve the quality of emergency medical care. PMID:29123744

  9. Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay.

    PubMed

    Allegra, Severine; Grattard, Florence; Girardot, Françoise; Riffard, Serge; Pozzetto, Bruno; Berthelot, Philippe

    2011-02-01

    Legionella spp. are frequently isolated in hospital water systems. Heat shock (30 min at 70°C) is recommended by the World Health Organization to control its multiplication. The aim of the study was to evaluate retrospectively the efficacy of heat treatments by using a flow cytometry assay (FCA) able to identify viable but nonculturable (VBNC) cells. The study included Legionella strains (L. pneumophila [3 clusters] and L. anisa [1 cluster]) isolated from four hot water circuits of different hospital buildings in Saint-Etienne, France, during a 20-year prospective surveillance. The strains recovered from the different circuits were not epidemiologically related, but the strains isolated within a same circuit over time exhibited an identical genotypic profile. After an in vitro treatment of 30 min at 70°C, the mean percentage of viable cells and VBNC cells varied from 4.6% to 71.7%. The in vitro differences in heat sensitivity were in agreement with the observed efficacy of preventive and corrective heating measures used to control water contamination. These results suggest that Legionella strains can become heat resistant after heating treatments for a long time and that flow cytometry could be helpful to check the efficacy of heat treatments on Legionella spp. and to optimize the decontamination processes applied to water systems for the control of Legionella proliferation.

  10. Development of a flow cytometric method to analyze subpopulations of bacteria in probiotic products and dairy starters.

    PubMed

    Bunthof, Christine J; Abee, Tjakko

    2002-06-01

    Flow cytometry (FCM) is a rapid and sensitive technique that can determine cell numbers and measure various physiological characteristics of individual cells by using appropriate fluorescent probes. Previously, we developed an FCM assay with the viability probes carboxyfluorescein diacetate (cFDA) and TOTO-1 [1'-(4,4,7,7-tetramethyl-4,7-diazaundecamethylene)-bis-4-[3-methyl-2,3dihydro(benzo-1,3-oxazole)-2-methylidene]-1-(3'-trimethylammoniumpropyl)-pyridinium tetraiodide] for (stressed) lactic acid bacteria (C. J. Bunthof, K. Bloemen, P. Breeuwer, F. M. Rombouts, and T. Abee, Appl. Environ. Microbiol. 67:2326-2335, 2001). cFDA stains intact cells with enzymatic activity, and TOTO-1 stains membrane-permeabilized cells. Here we used this assay to study the viability of bacterial suspensions in milk, dairy fermentation starters, and probiotic products. To facilitate FCM analysis of bacteria in milk, a commercially available milk-clearing solution was used. The procedure was optimized to increase the signal-to-noise ratio. FCM enumerations were accurate down to a concentration of 10(5) cells ml(-1). The level of retrieval of Lactobacillus plantarum WCFS 1 suspended in milk was high, and viability was not affected by the procedure. The plate counts for cleared samples of untreated cell suspensions were nearly as high as the total FCM counts, and the correlation was strong (r > 0.99). In dairy fermentation starters and in probiotic products the FCM total cell counts were substantially higher than the numbers of CFU. Three functional populations could be distinguished: culturable cells, cells that are intact and metabolically active but not culturable, and permeabilized cells. The proportions of the populations differed in the products tested. This FCM method provides tools to assess the functionality of different populations in fermentation starters and probiotic products.

  11. Development of a Flow Cytometric Method To Analyze Subpopulations of Bacteria in Probiotic Products and Dairy Starters

    PubMed Central

    Bunthof, Christine J.; Abee, Tjakko

    2002-01-01

    Flow cytometry (FCM) is a rapid and sensitive technique that can determine cell numbers and measure various physiological characteristics of individual cells by using appropriate fluorescent probes. Previously, we developed an FCM assay with the viability probes carboxyfluorescein diacetate (cFDA) and TOTO-1 {1′-(4,4,7,7-tetramethyl-4,7-diazaundecamethylene)-bis-4-[3-methyl-2,3dihydro(benzo-1,3-oxazole)-2-methylidene]-1-(3′-trimethylammoniumpropyl)-pyridinium tetraiodide} for (stressed) lactic acid bacteria (C. J. Bunthof, K. Bloemen, P. Breeuwer, F. M. Rombouts, and T. Abee, Appl. Environ. Microbiol. 67:2326-2335, 2001). cFDA stains intact cells with enzymatic activity, and TOTO-1 stains membrane-permeabilized cells. Here we used this assay to study the viability of bacterial suspensions in milk, dairy fermentation starters, and probiotic products. To facilitate FCM analysis of bacteria in milk, a commercially available milk-clearing solution was used. The procedure was optimized to increase the signal-to-noise ratio. FCM enumerations were accurate down to a concentration of 105 cells ml−1. The level of retrieval of Lactobacillus plantarum WCFS 1 suspended in milk was high, and viability was not affected by the procedure. The plate counts for cleared samples of untreated cell suspensions were nearly as high as the total FCM counts, and the correlation was strong (r > 0.99). In dairy fermentation starters and in probiotic products the FCM total cell counts were substantially higher than the numbers of CFU. Three functional populations could be distinguished: culturable cells, cells that are intact and metabolically active but not culturable, and permeabilized cells. The proportions of the populations differed in the products tested. This FCM method provides tools to assess the functionality of different populations in fermentation starters and probiotic products. PMID:12039752

  12. Novel full‐spectral flow cytometry with multiple spectrally‐adjacent fluorescent proteins and fluorochromes and visualization of in vivo cellular movement

    PubMed Central

    Futamura, Koji; Sekino, Masashi; Hata, Akihiro; Ikebuchi, Ryoyo; Nakanishi, Yasutaka; Egawa, Gyohei; Kabashima, Kenji; Watanabe, Takeshi; Furuki, Motohiro

    2015-01-01

    Abstract Flow cytometric analysis with multicolor fluoroprobes is an essential method for detecting biological signatures of cells. Here, we present a new full‐spectral flow cytometer (spectral‐FCM). Unlike conventional flow cytometer, this spectral‐FCM acquires the emitted fluorescence for all probes across the full‐spectrum from each cell with 32 channels sequential PMT unit after dispersion with prism, and extracts the signals of each fluoroprobe based on the spectral shape of each fluoroprobe using unique algorithm in high speed, high sensitive, accurate, automatic and real‐time. The spectral‐FCM detects the continuous changes in emission spectra from green to red of the photoconvertible protein, KikGR with high‐spectral resolution and separates spectrally‐adjacent fluoroprobes, such as FITC (Emission peak (Em) 519 nm) and EGFP (Em 507 nm). Moreover, the spectral‐FCM can measure and subtract autofluorescence of each cell providing increased signal‐to‐noise ratios and improved resolution of dim samples, which leads to a transformative technology for investigation of single cell state and function. These advances make it possible to perform 11‐color fluorescence analysis to visualize movement of multilinage immune cells by using KikGR‐expressing mice. Thus, the novel spectral flow cytometry improves the combinational use of spectrally‐adjacent various FPs and multicolor fluorochromes in metabolically active cell for the investigation of not only the immune system but also other research and clinical fields of use. © 2015 The Authors. Cytometry Part A Published by Wiley Periodicals, Inc. on behalf of ISAC PMID:26217952

  13. Vortex methods for separated flows

    NASA Technical Reports Server (NTRS)

    Spalart, Philippe R.

    1988-01-01

    The numerical solution of the Euler or Navier-Stokes equations by Lagrangian vortex methods is discussed. The mathematical background is presented and includes the relationship with traditional point-vortex studies, convergence to smooth solutions of the Euler equations, and the essential differences between two and three-dimensional cases. The difficulties in extending the method to viscous or compressible flows are explained. Two-dimensional flows around bluff bodies are emphasized. Robustness of the method and the assessment of accuracy, vortex-core profiles, time-marching schemes, numerical dissipation, and efficient programming are treated. Operation counts for unbounded and periodic flows are given, and two algorithms designed to speed up the calculations are described.

  14. Analysis of synthetic and biological microparticles on several flow cytometric platforms***

    EPA Science Inventory

    Biological microparticles (MPs) are potentially important biomarkers for thrombosis, cancer, glomerulonephritis and other disease states. These MPs are generally accepted to be membrane vesicles extruded following cellular activation. While human blood cells range from 10-15 micr...

  15. Interaction of monopoles, dipoles, and turbulence with a shear flow

    NASA Astrophysics Data System (ADS)

    Marques Rosas Fernandes, V. H.; Kamp, L. P. J.; van Heijst, G. J. F.; Clercx, H. J. H.

    2016-09-01

    Direct numerical simulations have been conducted to examine the evolution of eddies in the presence of large-scale shear flows. The numerical experiments consist of initial-value-problems in which monopolar and dipolar vortices as well as driven turbulence are superposed on a plane Couette or Poiseuille flow in a periodic two-dimensional channel. The evolution of the flow has been examined for different shear rates of the background flow and different widths of the channel. Results found for retro-grade and pro-grade monopolar vortices are consistent with those found in the literature. Boundary layer vorticity, however, can significantly modify the straining and erosion of monopolar vortices normally seen for unbounded domains. Dipolar vortices are shown to be much more robust coherent structures in a large-scale shear flow than monopolar eddies. An analytical model for their trajectories, which are determined by self-advection and advection and rotation by the shear flow, is presented. Turbulent kinetic energy is effectively suppressed by the shearing action of the background flow provided that the shear is linear (Couette flow) and of sufficient strength. Nonlinear shear as present in the Poiseuille flow seems to even increase the turbulence strength especially for high shear rates.

  16. RG flows and instantons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gava, Edi

    2012-09-24

    In these two lectures I discuss RG flow solutions in (1,0) six dimensional supergravity involving SU(2) Yang-Mills instantons. in the conformally flat part of the 6D metric. The solutions interpolate between two (4,0) supersymmetric AdS{sub 3} Multiplication-Sign S{sup 3} backgrounds with different values of AdS{sub 3} and S{sup 3} radii and describe RG flows in the dual 2D SCFT. The flows described are of v.e.v. type, driven by a vacuum expectation value of a (not exactly) marginal operator of dimension 2 in the UV. We give an interpretation of the supergravity solution in terms of the D1/D5 system in typemore » I string theory on K3, whose effective field theory is expected to flow to a (4,0) SCFT in the infrared.« less

  17. Flow cytometric investigations of diploid and tetraploid plants and in vitro cultures of Datura stramonium and Hyoscyamus niger.

    PubMed

    Weber, Jost; Georgiev, Vasil; Pavlov, Atanas; Bley, Thomas

    2008-10-01

    Plant in vitro systems are valuable sources for the production of biological active substances. However, changed profiles of secondary metabolites, and low, variable yields possibly caused by genetic instabilities complicate their industrial implementation. DNA profiling of plant in vitro cultures may provide data for the selection of highly producing in vitro cultures. Diploid and tetraploid Datura stramonium and Hyoscyamus niger plant as well as calli, and hairy root lines derived from them were analyzed by flow cytometry. Plant in vitro cultures undergo several cycles of endoreduplication more than the explants from which they were obtained. The highest cycle values were observed in calli (e.g. 1.19 for diploid H. niger) possibly induced by the growth factors. However, hairy roots cultivated without growth factor exhibited significant degrees of endoreduplication (cycle value 0.88 for diploid H. niger). Sets of five hairy root lines from each plant and ploidy level showed consistent within-set ploidy patterns. The ploidy profiles of investigated plant in vitro and in vivo differ. For the first time we report that hairy roots of two Solanaceae species undergo endoreduplication. Theploidy profiles of in vitro cultures (hairy roots and calli) seem to be influenced by the genome size, the growth factors applied, and the type of in vitro culture. The transformation of several hairy root lines showed no differences in the ploidy patterns. Copyright 2008 International Society for Advancement of Cytometry.

  18. Prognostic significance of DNA ploidy in adenocarcinoma of the pancreas. A flow cytometric study of paraffin-embedded specimens.

    PubMed

    Porschen, R; Remy, U; Bevers, G; Schauseil, S; Hengels, K J; Borchard, F

    1993-06-15

    The prognostic significance of tumor DNA ploidy in patients with cancer of the pancreas has not been defined because conflicting results have been reported. DNA content was measured in 56 ductal adenocarcinomas of the pancreas. DNA ploidy status was evaluated by flow cytometry in nuclei isolated from paraffin-embedded tumor tissues. An abnormal DNA stemline was observed in 27 (48%) patients. The percentage of aneuploid tumors was significantly increased in tumors classified as Stage III/IV (53%) compared with those classified as Stage I (22%). A borderline significant association existed between DNA ploidy and radicality of surgery (P = 0.08). The median survival of patients with diploid carcinomas was 6.9 months (standard error, +/- 0.9) in comparison to 4.5 +/- 1.2 months for patients with aneuploid tumors (P = 0.013 by generalized Wilcoxon test; P = 0.023 by generalized Savage test). Although a selection bias cannot be excluded, survival of patients with a radical resection was longer than that of patients with a nonradical resection (P = 0.0008 and P = 0.0085, respectively). In addition, presence of distant metastasis (P = 0.0006 [Wilcoxon test] and P = 0.033 [Savage test]) could be identified as a prognostic factor. In a Cox regression model, results of surgery and DNA ploidy were independent prognostic variables. Because DNA ploidy has a significant impact on prognosis in pancreatic cancer, it should be used as a variable for stratified randomization of patients in therapeutic trials.

  19. Flow Cytometric Immunobead Assay for Detection of BCR-ABL1 Fusion Proteins in Chronic Myleoid Leukemia: Comparison with FISH and PCR Techniques

    PubMed Central

    Recchia, Anna Grazia; Caruso, Nadia; Bossio, Sabrina; Pellicanò, Mariavaleria; De Stefano, Laura; Franzese, Stefania; Palummo, Angela; Abbadessa, Vincenzo; Lucia, Eugenio; Gentile, Massimo; Vigna, Ernesto; Caracciolo, Clementina; Agostino, Antolino; Galimberti, Sara; Levato, Luciano; Stagno, Fabio; Molica, Stefano; Martino, Bruno; Vigneri, Paolo; Di Raimondo, Francesco; Morabito, Fortunato

    2015-01-01

    Chronic Myeloid Leukemia (CML) is characterized by a balanced translocation juxtaposing the Abelson (ABL) and breakpoint cluster region (BCR) genes. The resulting BCR-ABL1 oncogene leads to increased proliferation and survival of leukemic cells. Successful treatment of CML has been accompanied by steady improvements in our capacity to accurately and sensitively monitor therapy response. Currently, measurement of BCR-ABL1 mRNA transcript levels by real-time quantitative PCR (RQ-PCR) defines critical response endpoints. An antibody-based technique for BCR-ABL1 protein recognition could be an attractive alternative to RQ-PCR. To date, there have been no studies evaluating whether flow-cytometry based assays could be of clinical utility in evaluating residual disease in CML patients. Here we describe a flow-cytometry assay that detects the presence of BCR-ABL1 fusion proteins in CML lysates to determine the applicability, reliability, and specificity of this method for both diagnosis and monitoring of CML patients for initial response to therapy. We show that: i) CML can be properly diagnosed at onset, (ii) follow-up assessments show detectable fusion protein (i.e. relative mean fluorescent intensity, rMFI%>1) when BCR-ABL1IS transcripts are between 1–10%, and (iii) rMFI% levels predict CCyR as defined by FISH analysis. Overall, the FCBA assay is a rapid technique, fully translatable to the routine management of CML patients. PMID:26111048

  20. [Prokaryotic expression, purification and biological activity analysis of recombinant β-Lactamase protein].

    PubMed

    Zhou, Xiao-liang; Shi, Pei-ji; Wang, Hao

    2011-01-01

    To prepare RGD4CβL fusion protein using prokaryotic expression system and evaluate the biological activity of the RGD4CβL. RGD4CβL gene was cloned into pColdII to contruct β-Lactamase prokaryotic expression vector. After transformation, the recombinant vector was induced to express recombinant protein RGD4CβL by IPTG in E.coli BL(DE3). The recombinant protein was purified by Ni-NTA resin under denaturing condition and then dialyzed to renature. The tumor cell targeting ability of the recombinant protein was analyzed by flow cytometric analysis. After cleavage and purification, β-Lactamase moiety showed the expected size of 42 000 on Tricine-SDS-PAGE, and was further confirmed by Western blotting. Based on flow cytometric analysis, the purified protein specially targeted breast cancer cell line MCF-7. This research successfully estiblished a method for prokaryotic expression and purification of β-lactamase. These results suggest the potential use of the protein as an agent for ADEPT.

  1. Multiparameter flow cytometric analysis of a pH sensitive formyl peptide with application to receptor structure and processing kinetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fay, S.P.; Domalewski, M.D.; Houghton, T.G.

    1994-02-01

    Environmentally sensitive molecules have many potential cellular applications. The authors have investigated the utility of a pH sensitive ligand for the formyl peptide receptor, CHO-Met-Leu-Phe-Phe-Lys (SNAFL)-OH (SNAFL-seminaphthofluorescein), because in previous studies protonation has been used to explain the quenching when the fluorescinated formyl pentapeptide ligand binds to this receptor. Moreover, acidification in intracellular compartments is a general mechanism occurring in cells during processing of ligand-receptor complexes. Because the protonated form of SNAFL is excited at 488 nm with emission at 530 nm and the unprotonated form is excited at 568 nm with emission at 650 nm, the ratio of protonatedmore » and unprotonated forms can be examined by multiparameter flow cytometry. The authors found that the receptor-bound ligand is sensitive to both the extracellular and intracellular pH. There is a small increase in the pK[sub a] of the ligand upon binding to the receptor consistent with protonation in the binding pocket. Once internalized, spectral changes in the probe consistent with acidification and ligand dissociation from the receptor are observed. 22 refs., 4 figs.« less

  2. Binding of fluoresceinated epidermal growth factor to A431 cell sub-populations studied using a model-independent analysis of flow cytometric fluorescence data.

    PubMed Central

    Chatelier, R C; Ashcroft, R G; Lloyd, C J; Nice, E C; Whitehead, R H; Sawyer, W H; Burgess, A W

    1986-01-01

    A method is developed for determining ligand-cell association parameters from a model-free analysis of data obtained with a flow cytometer. The method requires measurement of the average fluorescence per cell as a function of ligand and cell concentration. The analysis is applied to data obtained for the binding of fluoresceinated epidermal growth factor to a human epidermoid carcinoma cell line, A431. The results indicate that the growth factor binds to two classes of sites on A431 cells: 4 X 10(4) sites with a dissociation constant (KD) of less than or equal to 20 pM, and 1.5 X 10(6) sites with a KD of 3.7 nM. A derived plot of the average fluorescence per cell versus the average number of bound ligands per cell is used to construct binding isotherms for four sub-populations of A431 cells fractionated on the basis of low-angle light scatter. The four sub-populations bind the ligand with equal affinity but differ substantially in terms of the number of binding sites per cell. We also use this new analysis to critically evaluate the use of 'Fluorotrol' as a calibration standard in flow cytometry. PMID:3015587

  3. Species-specific viability analysis of Pseudomonas aeruginosa, Burkholderia cepacia and Staphylococcus aureus in mixed culture by flow cytometry

    PubMed Central

    2014-01-01

    Background Bacterial species coexist commonly in mixed communities, for instance those occurring in microbial infections of humans. Interspecies effects contribute to alterations in composition of communities with respect to species and thus, to the course and severity of infection. Therefore, knowledge concerning growth and viability of single species in medically-relevant mixed communities is of high interest to resolve complexity of interspecies dynamics and to support development of treatment strategies. In this study, a flow cytometric method was established to assess the species-specific viability in defined three-species mixed cultures. The method enables the characterization of viability of Pseudomonas aeruginosa, Burkholderia cepacia and Staphylococcus aureus, which are relevant to lung infections of Cystic Fibrosis (CF) patients. The method combines fluorescence detection by antibody and lectin labeling with viability fluorescence staining using SYBR®Green I and propidium iodide. In addition, species-specific cell enumeration analysis using quantitative terminal restriction fragment length polymorphisms (qT-RFLP) was used to monitor the growth dynamics. Finally, to investigate the impact of substrate availability on growth and viability, concentrations of main substrates and metabolites released were determined. Results For each species, the time course of growth and viability during mixed culture cultivations was obtained by using qT-RFLP analysis in combination with flow cytometry. Comparison between mixed and pure cultures revealed for every species differences in growth properties, e.g. enhanced growth of P. aeruginosa in mixed culture. Differences were also observed for B. cepacia and S. aureus in the time course of viability, e.g. an early and drastic reduction of viability of S. aureus in mixed culture. Overall, P. aeruginosa clearly dominated the mixed culture with regard to obtained cell concentrations. Conclusions In combination with q

  4. Particle dynamics during nanoparticle synthesis by laser ablation in a background gas

    NASA Astrophysics Data System (ADS)

    Nakata, Yoshiki; Muramoto, Junichi; Okada, Tatsuo; Maeda, Mitsuo

    2002-02-01

    Particle dynamics during Si nanoparticle synthesis in a laser-ablation plume in different background gases were investigated by laser-spectroscopic imaging techniques. Two-dimensional laser induced fluorescence and ultraviolet Rayleigh scattering techniques were used to visualize the spatial distribution of the Si atoms and nanoparticles grown, respectively. We have developed a visualization technique called re-decomposition laser-induced fluorescence to observe small nanoparticles (hereafter called clusters) which are difficult to observe by the conventional imaging techniques. In this article, the whole process of nanoparticle synthesis in different background gases of He, Ne, Ar, N2 and O2 was investigated by these techniques. In He, Ne, Ar and N2 background gases at 10 Torr, the clustering of the Si atoms started 200, 250, 300 and 800 μs after ablation, respectively. The growth rate of the clusters in He background gas was much larger than that in the other gases. The spatial distributions of the Si nanoparticles were mushroom like in He, N2 and O2, and column like in Ne and Ar. It is thought that the difference in distribution was caused by differences in the flow characteristics of the background gases, which would imply that the viscosity of the background gas is one of the main governing parameters.

  5. Distribution of the background gas in the MITICA accelerator

    NASA Astrophysics Data System (ADS)

    Sartori, E.; Dal Bello, S.; Serianni, G.; Sonato, P.

    2013-02-01

    MITICA is the ITER neutral beam test facility to be built in Padova for the generation of a 40A D- ion beam with a 16×5×16 array of 1280 beamlets accelerated to 1MV. The background gas pressure distribution and the particle flows inside MITICA accelerator are critical aspects for stripping losses, generation of secondary particles and beam non-uniformities. To keep the stripping losses in the extraction and acceleration stages reasonably low, the source pressure should be 0.3 Pa or less. The gas flow in MITICA accelerator is being studied using a 3D Finite Element code, named Avocado. The gas-wall interaction model is based on the cosine law, and the whole vacuum system geometry is represented by a view factor matrix based on surface discretization and gas property definitions. Pressure distribution and mutual fluxes are then solved linearly. In this paper the result of a numerical simulation is presented, showing the steady-state pressure distribution inside the accelerator when gas enters the system at room temperature. The accelerator model is limited to a horizontal slice 400 mm high (1/4 of the accelerator height). The pressure profile at solid walls and through the beamlet axis is obtained, allowing the evaluation and the discussion of the background gas distribution and nonuniformity. The particle flux at the inlet and outlet boundaries (namely the grounded grid apertures and the lateral conductances respectively) will be discussed.

  6. Flow Cytometry Pulse Width Data Enables Rapid and Sensitive Estimation of Biomass Dry Weight in the Microalgae Chlamydomonas reinhardtii and Chlorella vulgaris

    PubMed Central

    Chioccioli, Maurizio; Hankamer, Ben; Ross, Ian L.

    2014-01-01

    Dry weight biomass is an important parameter in algaculture. Direct measurement requires weighing milligram quantities of dried biomass, which is problematic for small volume systems containing few cells, such as laboratory studies and high throughput assays in microwell plates. In these cases indirect methods must be used, inducing measurement artefacts which vary in severity with the cell type and conditions employed. Here, we utilise flow cytometry pulse width data for the estimation of cell density and biomass, using Chlorella vulgaris and Chlamydomonas reinhardtii as model algae and compare it to optical density methods. Measurement of cell concentration by flow cytometry was shown to be more sensitive than optical density at 750 nm (OD750) for monitoring culture growth. However, neither cell concentration nor optical density correlates well to biomass when growth conditions vary. Compared to the growth of C. vulgaris in TAP (tris-acetate-phosphate) medium, cells grown in TAP + glucose displayed a slowed cell division rate and a 2-fold increased dry biomass accumulation compared to growth without glucose. This was accompanied by increased cellular volume. Laser scattering characteristics during flow cytometry were used to estimate cell diameters and it was shown that an empirical but nonlinear relationship could be shown between flow cytometric pulse width and dry weight biomass per cell. This relationship could be linearised by the use of hypertonic conditions (1 M NaCl) to dehydrate the cells, as shown by density gradient centrifugation. Flow cytometry for biomass estimation is easy to perform, sensitive and offers more comprehensive information than optical density measurements. In addition, periodic flow cytometry measurements can be used to calibrate OD750 measurements for both convenience and accuracy. This approach is particularly useful for small samples and where cellular characteristics, especially cell size, are expected to vary during growth. PMID

  7. Holographic anisotropic background with confinement-deconfinement phase transition

    NASA Astrophysics Data System (ADS)

    Aref'eva, Irina; Rannu, Kristina

    2018-05-01

    We present new anisotropic black brane solutions in 5D Einstein-dilaton-two-Maxwell system. The anisotropic background is specified by an arbitrary dynamical exponent ν, a nontrivial warp factor, a non-zero dilaton field, a non-zero time component of the first Maxwell field and a non-zero longitudinal magnetic component of the second Maxwell field. The blackening function supports the Van der Waals-like phase transition between small and large black holes for a suitable first Maxwell field charge. The isotropic case corresponding to ν = 1 and zero magnetic field reproduces previously known solutions. We investigate the anisotropy influence on the thermodynamic properties of our background, in particular, on the small/large black holes phase transition diagram. We discuss applications of the model to the bottom-up holographic QCD. The RG flow interpolates between the UV section with two suppressed transversal coordinates and the IR section with the suppressed time and longitudinal coordinates due to anisotropic character of our solution. We study the temporal Wilson loops, extended in longitudinal and transversal directions, by calculating the minimal surfaces of the corresponding probing open string world-sheet in anisotropic backgrounds with various temperatures and chemical potentials. We find that dynamical wall locations depend on the orientation of the quark pairs, that gives a crossover transition line between confinement/deconfinement phases in the dual gauge theory. Instability of the background leads to the appearance of the critical points ( μ ϑ,b , T ϑ,b ) depending on the orientation ϑ of quark-antiquark pairs in respect to the heavy ions collision line.

  8. Genetic analyses of endoreduplication in Zea mays endosperm: evidence of sporophytic and zygotic maternal control.

    PubMed

    Dilkes, Brian P; Dante, Ricardo A; Coelho, Cintia; Larkins, Brian A

    2002-03-01

    Flow cytometry was used to assess the variability of endoreduplication in endosperms of maize inbred lines. Little variation was found between midwestern dent types, and high levels of endoreduplication were observed in popcorns. Endoreduplication is different between inbred lines by 13-18 days after pollination, and flow cytometric analysis of ploidy level was feasible until 20 DAP. To study the genetic regulation of endoreduplication, four inbreds were crossed to B73 and developing endosperms from both parental, reciprocal F(1), and backcross generations were subjected to flow cytometric analysis. Three measurements of endoreduplication were calculated from these data and analyzed as quantitative genetic traits. Multiple models of trait inheritance were considered including triploid, diploid, sporophytic maternal, and maternal and paternal zygotic nuclear inheritance. Maternal zygotic effects, often considered a form of parental imprinting, and maternal sporophytic effects were detected. To test the feasibility of introgressing a high endoreduplication phenotype into a midwestern dent inbred line, a backcross population was generated from B73 x Sg18. Parental and progeny endoreduplication levels were compared and heritabilities assessed. The heritabilities calculated from these data generally agree with the values calculated in the larger crossing experiments.

  9. An analytical study on groundwater flow in drainage basins with horizontal wells

    NASA Astrophysics Data System (ADS)

    Wang, Jun-Zhi; Jiang, Xiao-Wei; Wan, Li; Wang, Xu-Sheng; Li, Hailong

    2014-06-01

    Analytical studies on release/capture zones are often limited to a uniform background groundwater flow. In fact, for basin-scale problems, the undulating water table would lead to the development of hierarchically nested flow systems, which are more complex than a uniform flow. Under the premise that the water table is a replica of undulating topography and hardly influenced by wells, an analytical solution of hydraulic head is derived for a two-dimensional cross section of a drainage basin with horizontal injection/pumping wells. Based on the analytical solution, distributions of hydraulic head, stagnation points and flow systems (including release/capture zones) are explored. The superposition of injection/pumping wells onto the background flow field leads to the development of new internal stagnation points and new flow systems (including release/capture zones). Generally speaking, the existence of n injection/pumping wells would result in up to n new internal stagnation points and up to 2n new flow systems (including release/capture zones). The analytical study presented, which integrates traditional well hydraulics with the theory of regional groundwater flow, is useful in understanding basin-scale groundwater flow influenced by human activities.

  10. Flow cytometric sex sorting affects CD4 membrane distribution and binding of exogenous DNA on bovine sperm cells.

    PubMed

    Domingues, William Borges; da Silveira, Tony Leandro Rezende; Komninou, Eliza Rossi; Monte, Leonardo Garcia; Remião, Mariana Härter; Dellagostin, Odir Antônio; Corcini, Carine Dahl; Varela Junior, Antônio Sergio; Seixas, Fabiana Kömmling; Collares, Tiago; Campos, Vinicius Farias

    2017-08-01

    Bovine sex-sorted sperm have been commercialized and successfully used for the production of transgenic embryos of the desired sex through the sperm-mediated gene transfer (SMGT) technique. However, sex-sorted sperm show a reduced ability to internalize exogenous DNA. The interaction between sperm cells and the exogenous DNA has been reported in other species to be a CD4-like molecule-dependent process. The flow cytometry-based sex-sorting process subjects the spermatozoa to different stresses causing changes in the cell membrane. The aim of this study was to elucidate the relationship between the redistribution of CD4-like molecules and binding of exogenous DNA to sex-sorted bovine sperm. In the first set of experiments, the membrane phospholipid disorder and the redistribution of the CD4 were evaluated. The second set of experiments was conducted to investigate the effect of CD4 redistribution on the mechanism of binding of exogenous DNA to sperm cells and the efficiency of lipofection in sex-sorted bovine sperm. Sex-sorting procedure increased the membrane phospholipid disorder and induced the redistribution of CD4-like molecules. Both X-sorted and Y-sorted sperm had decreased DNA bound to membrane in comparison with the unsorted sperm; however, the binding of the exogenous DNA was significantly increased with the addition of liposomes. Moreover, we demonstrated that the number of sperm-bound exogenous DNA was decreased when these cells were preincubated with anti-bovine CD4 monoclonal antibody, supporting our hypothesis that CD4-like molecules indeed play a crucial role in the process of exogenous DNA/bovine sperm cells interaction.

  11. Experiments on Electron-Plasma Vortex Motion Driven by a Background Vorticity Gradient.

    NASA Astrophysics Data System (ADS)

    Kabantsev, A. A.; Driscoll, C. F.

    2000-10-01

    The interaction of self-trapped vortices with a background vorticity gradient plays an important role in 2D hydrodynamics, including various aspects of relaxation and self-organization of 2D turbulence. In the present experiments, electron plasma columns with monotonically decreasing density profiles provide a vorticity background with (negative) shear in the rotational flow. Clumps of extra electrons are then retrograde vortices, rotating against the background shear; and regions with a deficit of electrons (holes) are prograde vortices. Theory predicts that clumps move up the background gradient, and holes move down the gradient, with velocities which depend differently on the ratio of the vortex trapping length to vortex radius, l / r_v. The present experiments show quantitative agreement with recent theory and simulations,(D.A. Schecter and D.H.E. Dubin, Phys. Rev. Lett. 83), 2191 (1999). for the accessible regime of 0.2 < l/rv < 2. The experiments also show that moving clumps leave a spiral density wake, and that instability of these wakes results in a large number of long-lived holes.

  12. Chemo Resistance of Breast Cancer Stem Cells

    DTIC Science & Technology

    2006-05-01

    for stem cell markers , including CD44+ CD24- lin- by flow cytometry following chemotherapy residual tumor is assayed. As shown in Figure 3 below...the tumor and thus may contribute to relapse following therapy. This was to be accomplished by utilizing mouse xenograft models as well as markers ...limitation of utilizing these markers is that they are not suitable for immunochemical detection of tumor stem cells since they require flow cytometric

  13. 4β-Hydroxywithanolide E from Physalis peruviana (golden berry) inhibits growth of human lung cancer cells through DNA damage, apoptosis and G2/M arrest

    PubMed Central

    2010-01-01

    Background The crude extract of the fruit bearing plant, Physalis peruviana (golden berry), demonstrated anti-hepatoma and anti-inflammatory activities. However, the cellular mechanism involved in this process is still unknown. Methods Herein, we isolated the main pure compound, 4β-Hydroxywithanolide (4βHWE) derived from golden berries, and investigated its antiproliferative effect on a human lung cancer cell line (H1299) using survival, cell cycle, and apoptosis analyses. An alkaline comet-nuclear extract (NE) assay was used to evaluate the DNA damage due to the drug. Results It was shown that DNA damage was significantly induced by 1, 5, and 10 μg/mL 4βHWE for 2 h in a dose-dependent manner (p < 0.005). A trypan blue exclusion assay showed that the proliferation of cells was inhibited by 4βHWE in both dose- and time-dependent manners (p < 0.05 and 0.001 for 24 and 48 h, respectively). The half maximal inhibitory concentrations (IC50) of 4βHWE in H1299 cells for 24 and 48 h were 0.6 and 0.71 μg/mL, respectively, suggesting it could be a potential therapeutic agent against lung cancer. In a flow cytometric analysis, 4βHWE produced cell cycle perturbation in the form of sub-G1 accumulation and slight arrest at the G2/M phase with 1 μg/mL for 12 and 24 h, respectively. Using flow cytometric and annexin V/propidium iodide immunofluorescence double-staining techniques, these phenomena were proven to be apoptosis and complete G2/M arrest for H1299 cells treated with 5 μg/mL for 24 h. Conclusions In this study, we demonstrated that golden berry-derived 4βHWE is a potential DNA-damaging and chemotherapeutic agent against lung cancer. PMID:20167063

  14. Apomixis is not prevalent in subnival to nival plants of the European Alps

    PubMed Central

    Hörandl, Elvira; Dobeš, Christoph; Suda, Jan; Vít, Petr; Urfus, Tomáš; Temsch, Eva M.; Cosendai, Anne-Caroline; Wagner, Johanna; Ladinig, Ursula

    2011-01-01

    Background and Aims High alpine environments are characterized by short growing seasons, stochastic climatic conditions and fluctuating pollinator visits. These conditions are rather unfavourable for sexual reproduction of flowering plants. Apomixis, asexual reproduction via seed, provides reproductive assurance without the need of pollinators and potentially accelerates seed development. Therefore, apomixis is expected to provide selective advantages in high-alpine biota. Indeed, apomictic species occur frequently in the subalpine to alpine grassland zone of the European Alps, but the mode of reproduction of the subnival to nival flora was largely unknown. Methods The mode of reproduction in 14 species belonging to seven families was investigated via flow cytometric seed screen. The sampling comprised 12 species typical for nival to subnival plant communities of the European Alps without any previous information on apomixis (Achillea atrata, Androsace alpina, Arabis caerulea, Erigeron uniflorus, Gnaphalium hoppeanum, Leucanthemopsis alpina, Oxyria digyna, Potentilla frigida, Ranunculus alpestris, R. glacialis, R. pygmaeus and Saxifraga bryoides), and two high-alpine species with apomixis reported from other geographical areas (Leontopodium alpinum and Potentilla crantzii). Key Results Flow cytometric data were clearly interpretable for all 46 population samples, confirming the utility of the method for broad screenings on non-model organisms. Formation of endosperm in all species of Asteraceae was documented. Ratios of endosperm : embryo showed pseudogamous apomixis for Potentilla crantzii (ratio approx. 3), but sexual reproduction for all other species (ratios approx. 1·5). Conclusions The occurrence of apomixis is not correlated to high altitudes, and cannot be readily explained by selective forces due to environmental conditions. The investigated species have probably other adaptations to high altitudes to maintain reproductive assurance via sexuality. We

  15. Detection of Legionella pneumophila on clinical samples and susceptibility assessment by flow cytometry.

    PubMed

    Faria-Ramos, I; Costa-de-Oliveira, S; Barbosa, J; Cardoso, A; Santos-Antunes, J; Rodrigues, A G; Pina-Vaz, C

    2012-12-01

    Culture in selective media represents the standard diagnostic method to confirm Legionella pneumophila infection, despite requiring a prolonged incubation period; antigen detection by immunofluorescence (IFS) and molecular techniques are also available, but they do not allow antimicrobial susceptibility evaluation. Our objective was to optimise flow cytometry (FC) protocols for the detection of L. pneumophila in respiratory samples and for susceptibility evaluation to first-line drugs. In order to optimise the FC protocol, a specific monoclonal antibody, conjugated with fluorescein isothiocyanate (FITC), was incubated with type strain L. pneumophila ATCC 33152. The limit of detection was established by analysing serial dilutions of bacterial suspension; specificity was assayed using mixtures of prokaryotic and eukaryotic microorganisms. The optimised FC protocol was used to assess 50 respiratory samples and compared with IFS evaluation. The susceptibility profile to erythromycin, ciprofloxacin and levofloxacin was evaluated by FC using propidium iodide and SYBR Green fluorescent dyes; the results were compared with the Etest afterwards. The optimal specific antibody concentration was 20 μg/ml; 10(2)/ml Legionella organisms were detected by this protocol and no cross-reactions with other microorganisms were detected. The five positive respiratory samples (10 %) determined by IFS were also detected by FC, showing 100 % correlation. After 1 h of incubation at 37 °C with different antimicrobials, SYBR Green staining could discriminate between treated and non-treated cells. A novel flow cytometric approach for the detection of L. pneumophila from clinical samples and susceptibility evaluation is now available, representing an important step forward for the diagnosis of this very relevant agent.

  16. The new numerology of immunity mediated by virus-specific CD8(+) T cells.

    PubMed

    Doherty, P C

    1998-08-01

    Our understanding of virus-specific CD8(+) T cell responses is currently being revolutionized by peptide-based assay systems that allow flow cytometric analysis of effector and memory cytotoxic T lymphocyte populations. These techniques are, for the first time, putting the analysis of T-cell-mediated immunity on a quantitative basis.

  17. Background characterization of an ultra-low background liquid scintillation counter

    DOE PAGES

    Erchinger, J. L.; Orrell, John L.; Aalseth, C. E.; ...

    2017-01-26

    The Ultra-Low Background Liquid Scintillation Counter developed by Pacific Northwest National Laboratory will expand the application of liquid scintillation counting by enabling lower detection limits and smaller sample volumes. By reducing the overall count rate of the background environment approximately 2 orders of magnitude below that of commercially available systems, backgrounds on the order of tens of counts per day over an energy range of ~3–3600 keV can be realized. Finally, initial test results of the ULB LSC show promising results for ultra-low background detection with liquid scintillation counting.

  18. Effect of salt on cell viability and membrane integrity of Lactobacillus acidophilus, Lactobacillus casei and Bifidobacterium longum as observed by flow cytometry.

    PubMed

    Gandhi, Akanksha; Shah, Nagendra P

    2015-08-01

    The aim of the current study was to investigate the effect of varying sodium chloride concentrations (0-5%) on viability and membrane integrity of three probiotic bacteria, Lactobacillus acidophilus, Lactobacillus casei and Bifidobacterium longum, using conventional technique and flow cytometry. Double staining of cells by carboxyfluorescein diacetate (cFDA) and propidium iodide (PI) enabled to evaluate the effect of NaCl on cell esterase activity and membrane integrity. Observations from conventional culture technique were compared with findings from flow cytometric analysis on the metabolic activities of the cells and a correlation was observed between culturability and dye extrusion ability of L. casei and B. longum. However, a certain population of L. acidophilus was viable as per the plate count method but its efflux activity was compromised. Esterase activity of most bacteria reduced significantly (P < 0.05) during one week storage at NaCl concentrations greater than 3.5%. The study revealed that L. casei was least affected by higher NaCl concentrations among the three probiotic bacteria, as opposed to B. longum where the cF extrusion performance was greatly reduced during 1 wk storage. The metabolic activity and salt resistance of L. casei was found to be highest among the bacteria studied. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  19. Characterization of brightness and stoichiometry of bright particles by flow-fluorescence fluctuation spectroscopy.

    PubMed

    Johnson, Jolene; Chen, Yan; Mueller, Joachim D

    2010-11-03

    Characterization of bright particles at low concentrations by fluorescence fluctuation spectroscopy (FFS) is challenging, because the event rate of particle detection is low and fluorescence background contributes significantly to the measured signal. It is straightforward to increase the event rate by flow, but the high background continues to be problematic for fluorescence correlation spectroscopy. Here, we characterize the use of photon-counting histogram analysis in the presence of flow. We demonstrate that a photon-counting histogram efficiently separates the particle signal from the background and faithfully determines the brightness and concentration of particles independent of flow speed, as long as undersampling is avoided. Brightness provides a measure of the number of fluorescently labeled proteins within a complex and has been used to determine stoichiometry of protein complexes in vivo and in vitro. We apply flow-FFS to determine the stoichiometry of the group specific antigen protein within viral-like particles of the human immunodeficiency virus type-1 from the brightness. Our results demonstrate that flow-FFS is a sensitive method for the characterization of complex macromolecular particles at low concentrations. Copyright © 2010 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  20. Instabilities in a staircase stratified shear flow

    NASA Astrophysics Data System (ADS)

    Ponetti, G.; Balmforth, N. J.; Eaves, T. S.

    2018-01-01

    We study stratified shear flow instability where the density profile takes the form of a staircase of interfaces separating uniform layers. Internal gravity waves riding on density interfaces can resonantly interact due to a background shear flow, resulting in the Taylor-Caulfield instability. The many steps of the density profile permit a multitude of interactions between different interfaces, and a rich variety of Taylor-Caulfield instabilities. We analyse the linear instability of a staircase with piecewise-constant density profile embedded in a background linear shear flow, locating all the unstable modes and identifying the strongest. The interaction between nearest-neighbour interfaces leads to the most unstable modes. The nonlinear dynamics of the instabilities are explored in the long-wavelength, weakly stratified limit (the defect approximation). Unstable modes on adjacent interfaces saturate by rolling up the intervening layer into a distinctive billow. These nonlinear structures coexist when stacked vertically and are bordered by the sharp density gradients that are the remnants of the steps of the original staircase. Horizontal averages remain layer-like.

  1. KENNEDY SPACE CENTER, FLA. - Purple flowers flow across the sand from the dunes facing the Atlantic Ocean near Launch Pad 39A (background) at KSC. The beach is just south of the Canaveral National Seashore, which is managed by the National Wildlife Service.

    NASA Image and Video Library

    2003-08-19

    KENNEDY SPACE CENTER, FLA. - Purple flowers flow across the sand from the dunes facing the Atlantic Ocean near Launch Pad 39A (background) at KSC. The beach is just south of the Canaveral National Seashore, which is managed by the National Wildlife Service.

  2. Experimental investigation of coaxial-gun-formed plasmas injected into a background transverse magnetic field or plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Yue; Fisher, Dustin M.; Gilmore, Mark; Hsu, Scott C.; Lynn, Alan G.

    2018-05-01

    Injection of coaxial-gun-formed magnetized plasmas into a background transverse vacuum magnetic field or into a background magnetized plasma has been studied in the helicon-cathode (HelCat) linear plasma device at the University of New Mexico [M. Gilmore et al., J. Plasma Phys. 81, 345810104 (2015)]. A magnetized plasma jet launched into a background transverse magnetic field shows emergent kink stabilization of the jet due to the formation of a sheared flow in the jet above the kink stabilization threshold 0.1kVA [Y. Zhang et al., Phys. Plasmas 24, 110702 (2017)]. Injection of a spheromak-like plasma into a transverse background magnetic field led to the observation of finger-like structures on the side with a stronger magnetic field null between the spheromak and the background field. The finger-like structures are consistent with magneto-Rayleigh-Taylor instability. Jets or spheromaks launched into a background, low-β magnetized plasma show similar behavior as above, respectively, in both cases.

  3. On the impact of atmospheric thermal stability on the characteristics of nocturnal downslope flows

    NASA Astrophysics Data System (ADS)

    Ye, Z. J.; Garratt, J. R.; Segal, M.; Pielke, R. A.

    1990-04-01

    The impacts of background (or ambient) and local atmospheric thermal stabilities, and slope steepness, on nighttime thermally induced downslope flow in meso-β domains (i.e., 20 200 km horizontal extent) have been investigated using analytical and numerical model approaches. Good agreement between the analytical and numerical evaluations was found. It was concluded that: (i) as anticipated, the intensity of the downslope flow increases with increased slope steepness, although the depth of the downslope flow was found to be insensitive to slope steepness in the studied situations; (ii) the intensity of the downslope flow is generally independent of background atmospheric thermal stability; (iii) for given integrated nighttime cooling across the nocturnal boundary layer (NBL), Q s the local atmospheric thermal stability exerts a strong influence on downslope flow behavior: the downslope flow intensity increases when local atmospheric thermal stability increases; and (iv) the downslope flow intensity is proportional to Q s 1/2.

  4. Current Background Noise Sources and Levels in the NASA Ames 40- by 80-Foot Wind Tunnel: A Status Report

    NASA Technical Reports Server (NTRS)

    Allen, Christopher S.; Jaeger, Stephen; Soderman, Paul; Koga, Dennis (Technical Monitor)

    1999-01-01

    Background noise measurements were made of the acoustic environment in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The measurements were acquired subsequent to the 40x80 Aeroacoustic Modernization Project, which was undertaken to improve the anechoic characteristics of the 40x80's closed test section as well as reduce the levels of background noise in the facility. The resulting 40x80 anechoic environment was described by Soderman et. al., and the current paper describes the resulting 40x80 background noise, discusses the sources of the noise, and draws comparisons to previous 40x80 background noise levels measurements. At low wind speeds or low frequencies, the 40x80 background noise is dominated by the fan drive system. To obtain the lowest fan drive noise for a given tunnel condition, it is possible in the 40x80 to reduce the fans' rotational speed and adjust the fans' blade pitch, as described by Schmidtz et. al. This idea is not new, but has now been operationally implemented with modifications for increased power at low rotational speeds. At low to mid-frequencies and at higher wind speeds, the dominant noise mechanism was thought to be caused by the surface interface of the previous test section floor acoustic lining. In order to reduce this noise mechanism, the new test section floor lining was designed to resist the pumping of flow in and out of the space between the grating slats required to support heavy equipment. In addition, the lining/flow interface over the entire test section was designed to be smoother and quieter than the previous design. At high wind speeds or high frequencies, the dominant source of background noise in the 40x80 is believed to be caused by the response of the in-flow microphone probes (required by the nature of the closed test section) to the fluctuations in the freestream flow. The resulting background noise levels are also different for probes of various

  5. Traffic Flow Management and Optimization

    NASA Technical Reports Server (NTRS)

    Rios, Joseph Lucio

    2014-01-01

    This talk will present an overview of Traffic Flow Management (TFM) research at NASA Ames Research Center. Dr. Rios will focus on his work developing a large-scale, parallel approach to solving traffic flow management problems in the national airspace. In support of this talk, Dr. Rios will provide some background on operational aspects of TFM as well a discussion of some of the tools needed to perform such work including a high-fidelity airspace simulator. Current, on-going research related to TFM data services in the national airspace system and general aviation will also be presented.

  6. A laboratory study of mean flow generation in rotating fluids by Reynolds stress gradients

    NASA Astrophysics Data System (ADS)

    McGuinness, D. S.; Boyer, D. L.; Fernando, H. J. S.

    2001-06-01

    Laboratory experiments were conducted that demonstrate that a mean azimuthal flow can be produced by introducing Reynolds stress gradients to a rotating fluid with zero initial mean flow. This mechanism may play a role in the generation of mean currents in coastal regions. The experiments entail the establishment of turbulence in a thin annular-shaped region centered within a cylindrical test cell through the use of a vertically oscillating grid. This region rests in a horizontal plane perpendicular to the vertical axis of the tank, and the entire system is placed on a turntable to simulate background rotation. Flow visualization techniques are used to depict qualitative features of the resulting flow field. Measurements of the mean and turbulent velocity fields are performed using a two-component laser-Doppler velocimeter. The results show how rectified currents (mean flows) can be generated via Reynolds stress gradients induced by periodic forcing of the grid. In the absence of background rotation, rectified flow is observed in the radial and vertical directions only. The presence of background rotation tends to organize these motions in that the flow tends to move parallel to the turbulent source, i.e., in the azimuthal direction, with the source (strong turbulence) located to the right, facing downstream. The influence of rotation on the Reynolds stresses and their gradients as well as on the ensuing mean flow is evaluated, and the observations are examined by considering individual contributions of the terms in the Reynolds-averaged momentum equations.

  7. Dark energy domination in the Virgocentric flow

    NASA Astrophysics Data System (ADS)

    Chernin, A. D.; Karachentsev, I. D.; Nasonova, O. G.; Teerikorpi, P.; Valtonen, M. J.; Dolgachev, V. P.; Domozhilova, L. M.; Byrd, G. G.

    2010-09-01

    Context. The standard ΛCDM cosmological model implies that all celestial bodies are embedded in a perfectly uniform dark energy background, represented by Einstein's cosmological constant, and experience its repulsive antigravity action. Aims: Can dark energy have strong dynamical effects on small cosmic scales as well as globally? Continuing our efforts to clarify this question, we now focus on the Virgo Cluster and the flow of expansion around it. Methods: We interpret the Hubble diagram from a new database of velocities and distances of galaxies in the cluster and its environment, using a nonlinear analytical model, which incorporates the antigravity force in terms of Newtonian mechanics. The key parameter is the zero-gravity radius, the distance at which gravity and antigravity are in balance. Results: 1. The interplay between the gravity of the cluster and the antigravity of the dark energy background determines the kinematical structure of the system and controls its evolution. 2. The gravity dominates the quasi-stationary bound cluster, while the antigravity controls the Virgocentric flow, bringing order and regularity to the flow, which reaches linearity and the global Hubble rate at distances ⪆15 Mpc. 3. The cluster and the flow form a system similar to the Local Group and its outflow. In the velocity-distance diagram, the cluster-flow structure reproduces the group-flow structure with a scaling factor of about 10; the zero-gravity radius for the cluster system is also 10 times larger. Conclusions: The phase and dynamical similarity of the systems on the scales of 1-30 Mpc suggests that a two-component pattern may be universal for groups and clusters: a quasi-stationary bound central component and an expanding outflow around it, caused by the nonlinear gravity-antigravity interplay with the dark energy dominating in the flow component.

  8. The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters

    PubMed Central

    Kojima, Masahiro; Irie, Keiko; Fukuda, Toshio; Arai, Fumihito; Hirose, Yuichi; Negoro, Makoto

    2012-01-01

    Background: Computer-based simulation is necessary to clarify the hemodynamics in brain aneurysm. Specifically for endovascular treatments, the effects of indwelling intravascular devices on blood stream need to be considered. The most recent technology used for cerebral aneurysm treatment is related to the use of flow diverters to reduce the amount of flow entering the aneurysm. To verify the differences of flow reduction, we analyzed multiple Enterprise stents and two kinds of flow diverters. Materials and Methods: In this research, we virtually modeled three kinds of commercial intracranial stents (Enterprise, Silk, and Pipeline) and mounted to fit into the vessel wall, and deployed across the neck of an IC-ophthalmic artery aneurysm. Also, we compared the differences among multiple Enterprise stents and two flow diverters in a standalone mode. Results: From the numerical results, the values of wall shear stress and pressure are reduced in proportion to the size of mesh, especially in the inflow area. However, the reduced velocity within the aneurysm sac by the multiple stents is not as significant as the flow diverters. Conclusions: This is the first study analyzing the flow alterations among multiple Enterprise stents and flow diverters. The placement of small meshed stents dramatically reduced the aneurysmal fluid movement. However, compared to the flow diverters, we did not observe the reduction of flow velocity within the aneurysm by the multiple stents. PMID:23559981

  9. Tolerance Induction of Temperature and Starvation with Tricalcium Phosphate on Preservation and Sporulation in Bacillus amyloliquefaciens Detected by Flow Cytometry.

    PubMed

    Shahrokh Esfahani, Samaneh; Emtiazi, Giti; Shafiei, Rasoul; Ghorbani, Najmeh; Zarkesh Esfahani, Seyed Hamid

    2016-09-01

    The Bacillus species have many applications in the preparation of various enzymes, probiotic, biofertilizer, and biomarkers for which the survival of resting cells and spore formation under different conditions are important. In this study, water and saline along with different mineral substances such as calcium carbonate, calcium phosphate, and silica were used for the detection of survival and preservation of Bacillus amyloliquefaciens. The results showed intensive death of resting cells at 8 °C, but significant survival at 28 °C after one month. However, preservation by minerals significantly decreased the rate of death and induced sporulation at both the temperatures. The resting cells were maintained at room temperature (about 60 % of the initial population survived after a month) in the presence of tricalcium phosphate. The results showed that temperature has more effect on sporulation compare with starvation. The sporulation in normal saline at 28 °C was 70 times more than that at 8 °C; meanwhile, addition of tricalcium phosphate increases sporulation by 90 times. Also, the FTIR data showed the interaction of tricalcium phosphate with spores and resting cells. The discrimination of sporulation from non-sporulation state was performed by nucleic acid staining with thiazole orange and detected by flow cytometry. The flow cytometric studies confirmed that the rates of sporulation in pure water were significantly more at 28 °C. This is the first report on the detection of bacterial spore with thiazole orange by flow cytometry and also on the interaction of tricalcium phosphate with spores by FTIR analyses.

  10. Two-Photon Flow Cytometry

    NASA Technical Reports Server (NTRS)

    Zhog, Cheng Frank; Ye, Jing Yong; Norris, Theodore B.; Myc, Andrzej; Cao, Zhengyl; Bielinska, Anna; Thomas, Thommey; Baker, James R., Jr.

    2004-01-01

    Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.

  11. INHIBITORY EFFECT OF CHITOSAN OLIGOSACCHARIDE ON HUMAN HEPATOMA CELLS IN VITRO

    PubMed Central

    Liu, Likun; Xin, Yi; Liu, Jia; Zhang, Ershao; Li, Weiling

    2017-01-01

    Background: Chitosan oligosaccharide, the degradation products of chitin, was reported to have a wide range of physiological functions and biological activities. In this study, we explored the inhibitory effect of Chitosan oligosaccharide on human hepatoma cells Materials and Methods: MTT assay was applied to detect cell viability of the human hepatoma cells treated with Chitosan oligosaccharide. Flow cytometric analysis was used to investigate the apoptosis of the human hepatoma cells treated with Chitosan oligosaccharide. We employed western blot to investigate the underlying mechanisms involved in the apoptosis. Results: Our data indicated that chitosan oligosaccharide dose-dependently inhibited the growth of hepatoma cells and induced apoptosis. On the molecular level, chitosan oligosaccharide decreased Bcl-2 and increased Caspase-3 expression which may be related to the apoptosis of hepatoma cells. Conclusion: Our results provide an experimental basis for the clinical development of Chitosan oligosaccharide as a novel anti-hepatoma drug. PMID:28638890

  12. On shapes and motion of an elongated bubble in downward liquid pipe flow

    NASA Astrophysics Data System (ADS)

    Fershtman, A.; Babin, V.; Barnea, D.; Shemer, L.

    2017-11-01

    In stagnant liquid, or in a steady upward liquid pipe flow, an elongated (Taylor) bubble has a symmetric shape. The translational velocity of the bubble is determined by buoyancy and the liquid velocity profile ahead of it. In downward flow, however, the symmetry of the bubble nose can be lost. Taylor bubble motion in downward flow is important in numerous applications such as chemical plants and cooling systems that often contain countercurrent gas-liquid flow. In the present study, the relation between the Taylor bubble shape and its translational velocity is investigated experimentally in a vertical pipe for various downward liquid flow rates. At higher downward velocities, the bubble may be forced by the background flow to propagate downward against buoyancy. In order to include those cases as well in our experimental analysis, the bubbles were initially injected into stagnant liquid, whereas the downward flow was initiated at a later stage. This experimental procedure allowed us to identify three distinct modes of translational velocities for a given downward background liquid flow; each velocity corresponds to a different bubble shape. Hydrodynamic mechanisms that govern the transition between the modes observed in the present study are discussed.

  13. Evaluation of zinc oxide nanoparticles toxicity on marine algae chlorella vulgaris through flow cytometric, cytotoxicity and oxidative stress analysis.

    PubMed

    Suman, T Y; Radhika Rajasree, S R; Kirubagaran, R

    2015-03-01

    The increasing industrial use of nanomaterials during the last decades poses a potential threat to the environment and in particular to organisms living in the aquatic environment. In the present study, the toxicity of zinc oxide nanoparticles (ZnO NPs) was investigated in Marine algae Chlorella vulgaris (C. vulgaris). High zinc dissociation from ZnONPs, releasing ionic zinc in seawater, is a potential route for zinc assimilation and ZnONPs toxicity. To examine the mechanism of toxicity, C. vulgaris were treated with 50mg/L, 100mg/L, 200mg/L and 300 mg/L ZnO NPs for 24h and 72h. The detailed cytotoxicity assay showed a substantial reduction in the viability dependent on dose and exposure. Further, flow cytometry revealed the significant reduction in C. vulgaris viable cells to higher ZnO NPs. Significant reductions in LDH level were noted for ZnO NPs at 300 mg/L concentration. The activity of antioxidant enzyme superoxide dismutase (SOD) significantly increased in the C. vulgaris exposed to 200mg/L and 300 mg/L ZnO NPs. The content of non-enzymatic antioxidant glutathione (GSH) significantly decreased in the groups with a ZnO NPs concentration of higher than 100mg/L. The level of lipid peroxidation (LPO) was found to increase as the ZnO NPs dose increased. The FT-IR analyses suggested surface chemical interaction between nanoparticles and algal cells. The substantial morphological changes and cell wall damage were confirmed through microscopic analyses (FESEM and CM). Copyright © 2014 Elsevier Inc. All rights reserved.

  14. A Method for Identification and Analysis of Non-Overlapping Myeloid Immunophenotypes in Humans

    PubMed Central

    Gustafson, Michael P.; Lin, Yi; Maas, Mary L.; Van Keulen, Virginia P.; Johnston, Patrick B.; Peikert, Tobias; Gastineau, Dennis A.; Dietz, Allan B.

    2015-01-01

    The development of flow cytometric biomarkers in human studies and clinical trials has been slowed by inconsistent sample processing, use of cell surface markers, and reporting of immunophenotypes. Additionally, the function(s) of distinct cell types as biomarkers cannot be accurately defined without the proper identification of homogeneous populations. As such, we developed a method for the identification and analysis of human leukocyte populations by the use of eight 10-color flow cytometric protocols in combination with novel software analyses. This method utilizes un-manipulated biological sample preparation that allows for the direct quantitation of leukocytes and non-overlapping immunophenotypes. We specifically designed myeloid protocols that enable us to define distinct phenotypes that include mature monocytes, granulocytes, circulating dendritic cells, immature myeloid cells, and myeloid derived suppressor cells (MDSCs). We also identified CD123 as an additional distinguishing marker for the phenotypic characterization of immature LIN-CD33+HLA-DR- MDSCs. Our approach permits the comprehensive analysis of all peripheral blood leukocytes and yields data that is highly amenable for standardization across inter-laboratory comparisons for human studies. PMID:25799053

  15. Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation

    PubMed Central

    Li, Liming; An, Liwen; Zhou, Xiaohang; Pan, Shuang; Meng, Xin; Ren, Yibin; Yang, Ke; Guan, Yifu

    2016-01-01

    To evaluate the clinical potential of high nitrogen nickel-free austenitic stainless steel (HNNF SS), we have compared the cellular and molecular responses of human umbilical artery smooth muscle cells (HUASMCs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel). CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profiles of HUASMCs exposed to HNNF SS and 316L SS, respectively. CCK-8 analysis demonstrated that HUASMCs cultured on HNNF SS proliferated more slowly than those on 316L SS. Flow cytometric analysis revealed that HNNF SS could activate more cellular apoptosis. The qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were up-regulated on HNNF SS. Thus, HNNF SS could reduce the HUASMC proliferation in comparison to 316L SS. The findings furnish valuable information for developing new biomedical materials for stent implantation. PMID:26727026

  16. Neural cell adhesion molecule-180 expression as a prognostic criterion in colorectal carcinoma: Feasible or not?

    PubMed Central

    Tascilar, Oge; Cakmak, Güldeniz Karadeniz; Tekin, Ishak Ozel; Emre, Ali Ugur; Ucan, Bulent Hamdi; Irkorucu, Oktay; Karakaya, Kemal; Gül, Mesut; Engin, Hüseyin Bülent; Comert, Mustafa

    2007-01-01

    AIM: To evaluate the frequency of neural cell adhesion molecule (NCAM)-180 expression in fresh tumor tissue samples and to discuss the prognostic value of NCAM-180 in routine clinical practice. METHODS: Twenty-six patients (16 men, 10 women) with colorectal cancer were included in the study. Fresh tumor tissue samples and macroscopically healthy proximal margins of each specimen were subjected to flow-cytometric analysis for NCAM-180 expression. RESULTS: Flow-cytometric analysis determined NCAM-180 expression in whole tissue samples of macroscopically healthy colorectal tissues. However, NCAM-180 expression was positive in only one case (3.84%) with well-differentiated Stage II disease who experienced no active disease at 30 mon follow-up. CONCLUSION: As a consequence of the limited number of cases in our series, it might not be possible to make a generalisation, nevertheless the routine use of NCAM-180 expression as a prognostic marker for colorectal carcinoma seems to be unfeasible and not cost-effective in clinical practice due to its very low incidence. PMID:17907291

  17. Biological behaviour of human umbilical artery smooth muscle cell grown on nickel-free and nickel-containing stainless steel for stent implantation

    NASA Astrophysics Data System (ADS)

    Li, Liming; An, Liwen; Zhou, Xiaohang; Pan, Shuang; Meng, Xin; Ren, Yibin; Yang, Ke; Guan, Yifu

    2016-01-01

    To evaluate the clinical potential of high nitrogen nickel-free austenitic stainless steel (HNNF SS), we have compared the cellular and molecular responses of human umbilical artery smooth muscle cells (HUASMCs) to HNNF SS and 316L SS (nickel-containing austenitic 316L stainless steel). CCK-8 analysis and flow cytometric analysis were used to assess the cellular responses (proliferation, apoptosis, and cell cycle), and quantitative real-time PCR (qRT-PCR) was used to analyze the gene expression profiles of HUASMCs exposed to HNNF SS and 316L SS, respectively. CCK-8 analysis demonstrated that HUASMCs cultured on HNNF SS proliferated more slowly than those on 316L SS. Flow cytometric analysis revealed that HNNF SS could activate more cellular apoptosis. The qRT-PCR results showed that the genes regulating cell apoptosis and autophagy were up-regulated on HNNF SS. Thus, HNNF SS could reduce the HUASMC proliferation in comparison to 316L SS. The findings furnish valuable information for developing new biomedical materials for stent implantation.

  18. Prospective identification of erythroid elements in cultured peripheral blood.

    PubMed

    Miller, J L; Njoroge, J M; Gubin, A N; Rodgers, G P

    1999-04-01

    We have developed a prospective approach to identify the generation of erythroid cells derived from cultured peripheral blood mononuclear cells (PBMC) by monitoring the expression of the cell surface protein CD48. Unpurified populations of PBMC obtained from the buffy coats of normal volunteers were grown in suspension culture in the absence or presence of erythropoietin. A profile of surface CD48 expression permitted a flow cytometric identification of erythropoietin responsive populations at various stages of their maturation. In the absence of erythropoietin (EPO) supplemented media, the CD48- cells represented <5% of the total population of PBMC remaining in culture. In cultures supplemented with 1 U/mL EPO, the mean percentage of CD48- cells increased to 34.7 + 14.9% (p < 0.01) after 14 days in culture. Coordinated CD34 and CD71 (transferrin receptor) expression, morphology, gamma-globin transcription, and colony formation in methylcellulose were observed during the 14-day culture period. Flow cytometric monitoring of bulk cultured PBMC provides a simple and reliable means for the prospective or real-time study of human erythropoiesis.

  19. Selling a gun to a stranger without a background check: acceptable behaviour?

    PubMed

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2018-06-01

    One way that guns get into the wrong hands is via gun sales without a background check. While the large majority of Americans support laws requiring universal background checks, no prior study has assessed whether Americans think it is acceptable behaviour to sell a gun to a stranger without a background check, whether or not there is a law against it. We sponsored a nationally representative survey of over 3900 American adults, oversampling gun owners, using an online panel provided by the survey firm Growth for Knowledge. Over 72% of American adults agree or strongly agree with the statement that 'whether it is legal or not, it is NOT acceptable to sell a gun to a stranger without a background check' and 11% disagree or strongly disagree. Subgroups less likely to agree are young adults, men, conservatives, those with less than a high school education and gun owners. Reducing the number of guns sold without a background check could help reduce the flow of guns to felons. Changes in normative attitudes and behaviours, as well as changes in law, could help accomplish this goal. Most Americans, including gun owners, believe selling a gun to a stranger without a background check is not acceptable behaviour. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Quantification of proteins by flow cytometry: Quantification of human hepatic transporter P-gp and OATP1B1 using flow cytometry and mass spectrometry.

    PubMed

    Hogg, Karen; Thomas, Jerry; Ashford, David; Cartwright, Jared; Coldwell, Ruth; Weston, Daniel J; Pillmoor, John; Surry, Dominic; O'Toole, Peter

    2015-07-01

    Flow cytometry is a powerful tool for the quantitation of fluorescence and is proven to be able to correlate the fluorescence intensity to the number of protein on cells surface. Mass spectroscopy can also be used to determine the number of proteins per cell. Here we have developed two methods, using flow cytometry and mass spectroscopy to quantify number of transporters in human cells. These two approaches were then used to analyse the same samples so that a direct comparison could be made. Transporters have a major impact on the behaviour of a diverse number of drugs in human systems. While active uptake studies by transmembrane protein transporters using model substrates are routinely undertaken in human cell lines and hepatocytes as part of drug discovery and development, the interpretation of these results is currently limited by the inability to quantify the number of transporters present in the test samples. Here we provide a flow cytometric method for accurate quantification of transporter levels both on the cell surface and within the cell, and compare this to a quantitative mass spectrometric approach. Two transporters were selected for the study: OATP1B1 (also known as SLCO1B1, LST-1, OATP-C, OATP2) due to its important role in hepatic drug uptake and elimination; P-gp (also known as P-glycoprotein, MDR1, ABCB1) as a well characterised system and due to its potential impact on oral bioavailability, biliary and renal clearance, and brain penetration of drugs that are substrates for this transporter. In all cases the mass spectrometric method gave higher levels than the flow cytometry method. However, the two methods showed very similar trends in the relative ratios of both transporters in the hepatocyte samples investigated. The P-gp antibody allowed quantitative discrimination between externally facing transporters located in the cytoplasmic membrane and the total number of transporters on and in the cell. The proportion of externally facing transporter

  1. Geometry: A Flow Proof Approach.

    ERIC Educational Resources Information Center

    McMurray, Robert

    The inspiration for this text was provided by an exposure to the flow proof approach to a proof format as opposed to the conventional two-column approach. Historical background is included, to provide a frame of reference to give the student an appreciation of the subject. The basic constructions are introduced early and briefly, to aid the…

  2. Isolating and Analyzing Cells of the Pancreas Mesenchyme by Flow Cytometry.

    PubMed

    Epshtein, Alona; Sakhneny, Lina; Landsman, Limor

    2017-01-28

    The pancreas is comprised of epithelial cells that are required for food digestion and blood glucose regulation. Cells of the pancreas microenvironment, including endothelial, neuronal, and mesenchymal cells were shown to regulate cell differentiation and proliferation in the embryonic pancreas. In the adult, the function and mass of insulin-producing cells were shown to depend on cells in their microenvironment, including pericyte, immune, endothelial, and neuronal cells. Lastly, changes in the pancreas microenvironment were shown to regulate pancreas tumorigenesis. However, the cues underlying these processes are not fully defined. Therefore, characterizing the different cell types that comprise the pancreas microenvironment and profiling their gene expression are crucial to delineate the tissue development and function under normal and diseased states. Here, we describe a method that allows for the isolation of mesenchymal cells from the pancreas of embryonic, neonatal, and adult mice. This method utilizes the enzymatic digestion of mouse pancreatic tissue and the subsequent fluorescence-activated cell sorting (FACS) or flow-cytometric analysis of labeled cells. Cells can be labeled by either immunostaining for surface markers or by the expression of fluorescent proteins. Cell isolation can facilitate the characterization of genes and proteins expressed in cells of the pancreas mesenchyme. This protocol was successful in isolating and culturing highly enriched mesenchymal cell populations from the embryonic, neonatal, and adult mouse pancreas.

  3. Detection of immunoglobulins on bacterial surface by laser flow cytometry: analysis between Haemophilus influenzae type b and Vibrio cholerae O1 of healthy mother-full term newborn sera.

    PubMed

    Cano-Morales, S; Luna-Guerrero, R; Mendez-Cuevas, G; Alvarado-Aleman, F J

    1996-01-01

    The identification of human IgG immunoglobulins on the surface of Vibrio cholerae O1, and Haemophilus influenzae type b microorganisms was assessed via a flow cytometric technique. A group of 31 healthy mother-full term newborn duo sera from a non-endemic cholera area was assayed. The sera of mothers and full-term newborns against both microorganisms were compared. The mean fluorescent intensity of the samples was not different at the 0.05 significance level by paired t-test. On the other hand, the immunoglobulins of newborn and mothers for V. cholerae O1 was notably lower when compared with H. influenzae type b microorganisms (p < 0.05 by paired t-test, t = -5.570 for mothers' sera, and t = -7.496 for the sera of the newborns). These data provide circumstantial evidence that LFC technique would be useful on bacteria-related serology.

  4. Preanalytical requirements for flow cytometric evaluation of platelet activation: choice of anticoagulant.

    PubMed

    Mody, M; Lazarus, A H; Semple, J W; Freedman, J

    1999-06-01

    Accurate assessment of in vivo or in vitro platelet activation requires optimal preanalytical conditions to prevent artefactual in vitro activation of the platelets. The choice of anticoagulant is one of the critical preanalytical conditions as anticoagulants exert different effects on the activation of platelets ex vivo. We tested the effectiveness of Diatube-H (also known as CTAD; sodium citrate, theophylline, adenosine and dipyridamole) and citrate vacutainer tubes in preventing artefactual activation of platelets and preserving functional reserve. Platelet surface expression of the CD62P (reflecting alpha granule release), CD63 (reflecting lysosomal release) and modulation of normal platelet membrane glycoproteins CD41a and CD42b, were measured in whole blood and in isolated platelets immediately after collection and at 6, 24 and 48 h after venipuncture. Samples taken into Diatube-H showed less spontaneous platelet activation than did those taken into citrate. To measure in vitro platelet functional reserve, thrombin was added as agonist to blood stored for varying periods up to 48 h. Although Diatube-H suppressed in vitro platelet activation for up to 4 h, in samples kept for 6-24 h before thrombin addition, the inhibitory effect was lost and platelets responded fully to agonist activation. Hence, Diatube-H preserved platelets and allowed for measurement of in vivo platelet activation as well as thrombin-induced in vitro platelet activation after 6-24 h, in both whole blood and isolated platelets.

  5. FLOW CYTOMETRIC DETECTION OF CRYPTOSPORIDIUM OOCYSTS IN HUMAN STOOL SAMPLES. (R824759)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  6. Paraelectric gas flow accelerator

    NASA Technical Reports Server (NTRS)

    Sherman, Daniel M. (Inventor); Wilkinson, Stephen P. (Inventor); Roth, J. Reece (Inventor)

    2001-01-01

    A substrate is configured with first and second sets of electrodes, where the second set of electrodes is positioned asymmetrically between the first set of electrodes. When a RF voltage is applied to the electrodes sufficient to generate a discharge plasma (e.g., a one-atmosphere uniform glow discharge plasma) in the gas adjacent to the substrate, the asymmetry in the electrode configuration results in force being applied to the active species in the plasma and in turn to the neutral background gas. Depending on the relative orientation of the electrodes to the gas, the present invention can be used to accelerate or decelerate the gas. The present invention has many potential applications, including increasing or decreasing aerodynamic drag or turbulence, and controlling the flow of active and/or neutral species for such uses as flow separation, altering heat flow, plasma cleaning, sterilization, deposition, etching, or alteration in wettability, printability, and/or adhesion.

  7. Measurement of intracellular nitric oxide (NO) production in shrimp haemocytes by flow cytometry.

    PubMed

    Xian, Jian-An; Guo, Hui; Li, Bin; Miao, Yu-Tao; Ye, Jian-Min; Zhang, Sheng-Peng; Pan, Xun-Bin; Ye, Chao-Xia; Wang, An-Li; Hao, Xuan-Ming

    2013-12-01

    A flow cytometric method to measure the production of intracellular nitric oxide (NO) was adapted for use with shrimp haemocytes. We applied fluorescent probe 4-amino-5-methylamino-2',7'-difluorofluorescein diacetate (DAF-FM DA) for NO detection in haemocytes from the tiger shrimp Penaeus monodon, and used flow cytometry to quantify fluorescence intensity in individual haemocyte. The optimized protocol for intracellular NO analysis consists to incubate haemocytes with DAF-FM DA at 10 μM for 60 min to determine the mean fluorescence intensity. Result showed that NO was also produced in the untreated shrimp haemocytes. NO level in granular cells and semigranular cells were much higher than that in hyaline cells. Defined by different characteristic of NO content, three subsets of haemocytes were observed. Zymosan A at dose of 10 or 100 particles per haemocyte triggered higher DAF-FM fluorescence intensity in granular and semigranular cells, than PMA that had no significant impact on all three cell types. These results indicate that granular and semigranular cells are the primary cells for NO generation. Cytochalasin B significantly inhibited the NO level induced by zymosan A. NG-Monomethyl-L-arginine (L-NMMA) and diphenylene iodonium chloride (DPI) significantly suppressed the DAF-FM fluorescence in haemocytes, but apocynin could not modulate it, indicating that the DAF-FM fluorescence was closely related to the activity of NO-synthase pathway. The NO donor sodium nitroprusside (SNP) improved the DAF-FM fluorescence in haemocytes, while the NO scavenger C-PTIO (2-(4-carboxyphenyl)-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide) significantly decreased the fluorescence, demonstrating that the fluorescence intensity of DAF-FM is mainly dependent on the intracellular NO level.

  8. Molecular identification of Armillaria gallica from the Niobrara Valley Preserve in Nebraska

    Treesearch

    Mee-Sook Kim; Ned B. Klopfenstein

    2011-01-01

    Armillaria isolates were collected from a unique forest ecosystem in the Niobrara Valley Preserve in Nebraska, USA, which comprises a glacial and early postglacial refugium in the central plains of North America. The isolates were collected from diverse forest trees representing a unique mixture of forest types. Combined methods of rDNA sequencing and flow cytometric...

  9. Numerical Simulations of Laminar Air-Water Flow of a Non-linear Progressive Wave at Low Wind Speed

    NASA Astrophysics Data System (ADS)

    Wen, X.; Mobbs, S.

    2014-03-01

    A numerical simulation for two-dimensional laminar air-water flow of a non-linear progressive water wave with large steepness is performed when the background wind speed varies from zero to the wave phase speed. It is revealed that in the water the difference between the analytical solution of potential flow and numerical solution of viscous flow is very small, indicating that both solutions of the potential flow and viscous flow describe the water wave very accurately. In the air the solutions of potential and viscous flows are very different due to the effects of viscosity. The velocity distribution in the airflow is strongly influenced by the background wind speed and it is found that three wind speeds, , (the maximum orbital velocity of a water wave), and (the wave phase speed), are important in distinguishing different features of the flow patterns.

  10. Onset of turbulence in accelerated high-Reynolds-number flow

    NASA Astrophysics Data System (ADS)

    Zhou, Ye; Robey, Harry F.; Buckingham, Alfred C.

    2003-05-01

    A new criterion, flow drive time, is identified here as a necessary condition for transition to turbulence in accelerated, unsteady flows. Compressible, high-Reynolds-number flows initiated, for example, in shock tubes, supersonic wind tunnels with practical limitations on dimensions or reservoir capacity, and high energy density pulsed laser target vaporization experimental facilities may not provide flow duration adequate for turbulence development. In addition, for critical periods of the overall flow development, the driving background flow is often unsteady in the experiments as well as in the physical flow situations they are designed to mimic. In these situations transition to fully developed turbulence may not be realized despite achievement of flow Reynolds numbers associated with or exceeding stationary flow transitional criteria. Basically our transitional criterion and prediction procedure extends to accelerated, unsteady background flow situations the remarkably universal mixing transition criterion proposed by Dimotakis [P. E. Dimotakis, J. Fluid Mech. 409, 69 (2000)] for stationary flows. This provides a basis for the requisite space and time scaling. The emphasis here is placed on variable density flow instabilities initiated by constant acceleration Rayleigh-Taylor instability (RTI) or impulsive (shock) acceleration Richtmyer-Meshkov instability (RMI) or combinations of both. The significant influences of compressibility on these developing transitional flows are discussed with their implications on the procedural model development. A fresh perspective for predictive modeling and design of experiments for the instability growth and turbulent mixing transitional interval is provided using an analogy between the well-established buoyancy-drag model with applications of a hierarchy of single point turbulent transport closure models. Experimental comparisons with the procedural results are presented where use is made of three distinctly different types

  11. Enumerating viruses by using fluorescence and the nature of the nonviral background fraction.

    PubMed

    Pollard, Peter C

    2012-09-01

    Bulk fluorescence measurements could be a faster and cheaper way of enumerating viruses than epifluorescence microscopy, flow cytometry, or transmission electron microscopy (TEM). However, since viruses are not imaged, the background fluorescence compromises the signal, and we know little about its nature. In this paper the size ranges of nucleotides that fluoresce in the presence of SYBR gold were determined for wastewater and a range of freshwater samples using a differential filtration method. Fluorescence excitation-emission matrices (FEEMs) showed that >70% of the SYBR fluorescence was in the <10-nm size fraction (background) and was not associated with intact viruses. This was confirmed using TEM. The use of FEEMs to develop a fluorescence-based method for counting viruses is an approach that is fundamentally different from the epifluorescence microscopy technique used for enumerating viruses. This high fluorescence background is currently overlooked, yet it has had a most pervasive influence on the development of a simple fluorescence-based method for quantifying viral abundance in water.

  12. A GEIL flow cytometry consensus proposal for quantification of plasma cells: application to differential diagnosis between MGUS and myeloma.

    PubMed

    Frébet, Elise; Abraham, Julie; Geneviève, Franck; Lepelley, Pascale; Daliphard, Sylvie; Bardet, Valérie; Amsellem, Sophie; Guy, Julien; Mullier, Francois; Durrieu, Francoise; Venon, Marie-Dominique; Leleu, Xavier; Jaccard, Arnaud; Faucher, Jean-Luc; Béné, Marie C; Feuillard, Jean

    2011-05-01

    Flow cytometry is the sole available technique for quantification of tumor plasma-cells in plasma-cell disorders, but so far, no consensus technique has been proposed. Here, we report on a standardized, simple, robust five color flow cytometry protocol developed to characterize and quantify bone marrow tumor plasma-cells, validated in a multicenter manner. CD36 was used to exclude red blood cell debris and erythroblasts, CD38 and CD138 to detect plasma-cells, immunoglobulin light chains, CD45, CD56, CD19, and CD117 + CD34 to simultaneously characterize abnormal plasma-cells and quantify bone marrow precursors. This approach was applied in nine centers to 229 cases, including 25 controls. Tumor plasma-cells were detected in 96.8% of cases, all exhibiting an immunoglobulin peak over 1g/L. Calculation of a plasma-cells/precursors (PC/P) ratio allowed quantification of the plasma-cell burden independently from bone marrow hemodilution. The PC/P ratio yielded the best results in terms of sensitivity (81%) and specificity (84%) for differential diagnosis between MGUS and myeloma, when compared with other criteria. Combination of both the PC/P ratio and percentage of abnormal plasma-cells allowed the best differential diagnosis, but these criteria were discordant in 25% cases. Indirect calculation of CD19 negative PC/R ratio gave the best results in terms of sensitivity (87%). This standardized multiparameter flow cytometric approach allows for the detection and quantification of bone marrow tumor plasma-cell infiltration in nearly all cases of MGUS and myeloma, independently of debris and hemodilution. This approach may also prove useful for the detection of minimal residual disease. Copyright © 2010 International Clinical Cytometry Society.

  13. Flow for Exercise Adherence: Testing an Intrinsic Model of Health Behavior

    ERIC Educational Resources Information Center

    Petosa, R. Lingyak; Holtz, Brian

    2013-01-01

    Background: Health behavior theory generally does not include intrinsic motivation as a determinate of health practices. Purpose: The purpose of this study was to test the flow theory of exercise adherence. Flow theory posits that exercise can be intrinsically rewarding if the experiences of self/time transcendence and control/mastery are achieved…

  14. Application of Background Oriented Schlieren for Altitude Testing of Rocket Engines

    NASA Technical Reports Server (NTRS)

    Wernet, Mark P.; Stiegemeier, Benjamin R.

    2017-01-01

    A series of experiments was performed to determine the feasibility of using the Background Oriented Schlieren, BOS, flow visualization technique to image a simulated, small, rocket engine, plume under altitude test conditions. Testing was performed at the NASA Glenn Research Centers Altitude Combustion Stand, ACS, using nitrogen as the exhaust gas simulant. Due to limited optical access to the facility test capsule, all of the hardware required to conduct the BOS were located inside the vacuum chamber. During the test series 26 runs were performed using two different nozzle configurations with pressures in the test capsule around 0.3 psia. No problems were encountered during the test series resulting from the optical hardware being located in the test capsule and acceptable resolution images were captured. The test campaign demonstrated the ability of using the BOS technique for small, rocket engine, plume flow visualization during altitude testing.

  15. Predicting sediment delivery from debris flows after wildfire

    NASA Astrophysics Data System (ADS)

    Nyman, Petter; Smith, Hugh G.; Sherwin, Christopher B.; Langhans, Christoph; Lane, Patrick N. J.; Sheridan, Gary J.

    2015-12-01

    Debris flows are an important erosion process in wildfire-prone landscapes. Predicting their frequency and magnitude can therefore be critical for quantifying risk to infrastructure, people and water resources. However, the factors contributing to the frequency and magnitude of events remain poorly understood, particularly in regions outside western USA. Against this background, the objectives of this study were to i) quantify sediment yields from post-fire debris flows in southeast Australian highlands and ii) model the effects of landscape attributes on debris flow susceptibility. Sediment yields from post-fire debris flows (113-294 t ha- 1) are 2-3 orders of magnitude higher than annual background erosion rates from undisturbed forests. Debris flow volumes ranged from 539 to 33,040 m3 with hillslope contributions of 18-62%. The distribution of erosion and deposition above the fan were related to a stream power index, which could be used to model changes in yield along the drainage network. Debris flow susceptibility was quantified with a logistic regression and an inventory of 315 debris flow fans deposited in the first year after two large wildfires (total burned area = 2919 km2). The differenced normalised burn ratio (dNBR or burn severity), local slope, radiative index of dryness (AI) and rainfall intensity (from rainfall radar) were significant predictors in a susceptibility model, which produced excellent results in terms identifying channels that were eroded by debris flows (Area Under Curve, AUC = 0.91). Burn severity was the strongest predictor in the model (AUC = 0.87 when dNBR is used as single predictor) suggesting that fire regimes are an important control on sediment delivery from these forests. The analysis showed a positive effect of AI on debris flow probability in landscapes where differences in moisture regimes due to climate are associated with large variation in soil hydraulic properties. Overall, the results from this study based in the

  16. Particle and flow field holography: A critical survey

    NASA Technical Reports Server (NTRS)

    Trolinger, James D.

    1987-01-01

    A brief background is provided for the fields of particle and flow visualization holography. A summary of methods currently in use is given, followed by a discussion of more recent and unique applications. The problem of data reduction is discussed. A state of the art summary is then provided with a prognosis of the future of the field. Particle and flow visualization holography are characterized as powerful tools currently in wide use and with significant untapped potential.

  17. Dialysate Flow Rate and Delivered Kt/Vurea for Dialyzers with Enhanced Dialysate Flow Distribution

    PubMed Central

    Idoux, John W.; Hamdan, Hiba; Ouseph, Rosemary; Depner, Thomas A.; Golper, Thomas A.

    2011-01-01

    Summary Background and objectives Previous in vitro and clinical studies showed that the urea mass transfer-area coefficient (KoA) increased with increasing dialysate flow rate. This observation led to increased dialysate flow rates in an attempt to maximize the delivered dose of dialysis (Kt/Vurea). Recently, we showed that urea KoA was independent of dialysate flow rate in the range 500 to 800 ml/min for dialyzers incorporating features to enhance dialysate flow distribution, suggesting that increasing the dialysate flow rate with such dialyzers would not significantly increase delivered Kt/Vurea. Design, setting, participants, & measurements We performed a multi-center randomized clinical trial to compare delivered Kt/Vurea at dialysate flow rates of 600 and 800 ml/min in 42 patients. All other aspects of the dialysis prescription, including treatment time, blood flow rate, and dialyzer, were kept constant for a given patient. Delivered single-pool and equilibrated Kt/Vurea were calculated from pre- and postdialysis plasma urea concentrations, and ionic Kt/V was determined from serial measurements of ionic dialysance made throughout each treatment. Results Delivered Kt/Vurea differed between centers; however, the difference in Kt/Vurea between dialysate flow rates of 800 and 600 ml/min was NS by any measure (95% confidence intervals of −0.064 to 0.024 for single-pool Kt/Vurea, −0.051 to 0.023 for equilibrated Kt/Vurea, and −0.029 to 0.099 for ionic Kt/V). Conclusions These data suggest that increasing the dialysate flow rate beyond 600 ml/min for these dialyzers offers no benefit in terms of delivered Kt/Vurea. PMID:21799145

  18. Evaluation of a flow cytometry method to determine size and real refractive index distributions in natural marine particle populations.

    PubMed

    Agagliate, Jacopo; Röttgers, Rüdiger; Twardowski, Michael S; McKee, David

    2018-03-01

    A flow cytometric (FC) method was developed to retrieve particle size distributions (PSDs) and real refractive index (n r ) information in natural waters. Geometry and signal response of the sensors within the flow cytometer (CytoSense, CytoBuoy b.v., Netherlands) were characterized to form a scattering inversion model based on Mie theory. The procedure produced a mesh of diameter and n r isolines where each particle is assigned the diameter and n r values of the closest node, producing PSDs and particle real refractive index distributions. The method was validated using polystyrene bead standards of known diameter and polydisperse suspensions of oil with known n r , and subsequently applied to natural samples collected across a broad range of UK shelf seas. FC PSDs were compared with independent PSDs produced from data of two LISST-100X instruments (type B and type C). PSD slopes and features were found to be consistent between the FC and the two LISST-100X instruments, but LISST concentrations were found in disagreement with FC concentrations and with each other. FC n r values were found to agree with expected refractive index values of typical marine particle components across all samples considered. The determination of particle size and refractive index distributions enabled by the FC method has potential to facilitate identification of the contribution of individual subpopulations to the bulk inherent optical properties and biogeochemical properties of the particle population.

  19. Pre-existing Epithelial Diversity in Normal Human Livers: A Tissue-tethered Cytometric Analysis in Portal/Periportal Epithelial Cells

    PubMed Central

    Isse, Kumiko; Lesniak, Andrew; Grama, Kedar; Maier, John; Specht, Susan; Castillo-Rama, Marcela; Lunz, John; Roysam, Badrinath; Michalopoulos, George; Demetris, Anthony J.

    2012-01-01

    Routine light microscopy identifies two distinct epithelial cell populations in normal human livers: hepatocytes and biliary epithelial cells (BEC). Considerable epithelial diversity, however, arises during disease states when a variety of hepatocyte-BEC hybrid cells appear. This has been attributed to activation and differentiation of putative hepatic progenitor cells (HPC) residing in the Canals of Hering and/or metaplasia of pre-existing mature epithelial cells. A novel analytic approach consisting of multiplex labeling, high resolution whole slide imaging (WSI), and automated image analysis was used to determine if more complex epithelial cell phenotypes pre-existed in normal adult human livers, which might provide an alternative explanation for disease-induced epithelial diversity. “Virtually digested” WSI enabled quantitative cytometric analyses of individual cells displayed in a variety of formats (e.g. scatter plots) while still tethered to the WSI and tissue structure. We employed biomarkers specifically-associated with mature epithelial forms (HNF4α for hepatocytes, CK19 and HNF1β for BEC) and explored for the presence of cells with hybrid biomarker phenotypes. Results showed abundant hybrid cells in portal bile duct BEC, canals of Hering, and immediate periportal hepatocytes. These bi-potential cells likely serve as a reservoir for the epithelial diversity of ductular reactions, appearance of hepatocytes in bile ducts, and the rapid and fluid transition of BEC to hepatocytes, and vice versa. Conclusion Novel imaging and computational tools enable increased information extraction from tissue samples and quantify the considerable pre-existent hybrid epithelial diversity in normal human liver. This computationally-enabled tissue analysis approach offers much broader potential beyond the results presented here. PMID:23150208

  20. Clinical cytometry and progress in HLA antibody detection.

    PubMed

    Bray, Robert A; Tarsitani, Christine; Gebel, Howard M; Lee, Jar-How

    2011-01-01

    For most solid organ and selected stem cell transplants, antibodies against mismatched HLA antigens can lead to early and late graft failure. In recognition of the clinical significance of these antibodies, HLA antibody identification is one of the most critical functions of histocompatibility laboratories. Early methods employed cumbersome and insensitive complement-dependent cytotoxicity assays with a visual read-out. A little over 20 years ago flow cytometry entered the realm of antibody detection with the introduction of the flow cytometric crossmatch. Cytometry's increased sensitivity and objectivity quickly earned it popularity as a preferred crossmatch method especially for sensitized recipients. Although a sensitive method, the flow crossmatch was criticized as being "too sensitive" as false positive reactions were a know drawback. In part, the shortcomings of the flow crossmatch were due to the lack of corresponding sensitive and specific HLA antibody screening assays. However, in the mid 1990s, solid phase assays, capable of utilizing standard flow cytometers, were developed. These assays used microparticles coated with purified HLA molecules. Hence, the era of solid-phase, microparticle technology for HLA antibody detection was born permitting the sensitive and specific detection of HLA antibody. It was now possible to provide better correlation between HLA antibody detection and the flow cytometric crossmatch. This flow-based technology was soon followed by adaptation to the Luminex platform permitting a mutltiplexed approach for the identification and characterization of HLA antibodies. It is hoped that these technologies will ultimately lead to the identification of parameters that best correlate with and/or predict transplant outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Multiparametric flow cytometry in the diagnosis and characterization of low-grade pulmonary mucosa-associated lymphoid tissue lymphomas.

    PubMed

    Zaer, F S; Braylan, R C; Zander, D S; Iturraspe, J A; Almasri, N M

    1998-06-01

    Primary mucosa associated lymphoid tissue (MALT) lymphomas are rare neoplasms that seem to have a better prognosis than nodal lymphomas. Morphologic diagnosis of these lesions may be difficult because of features that overlap with those of benign lymphoid infiltrates. In this study, we assessed the contribution of multi-parametric flow cytometry in demonstrating clonality and further characterizing pulmonary MALT lymphomas. Based on a clinical or pathologic suspicion of MALT-lymphoma, 3 transbronchial biopsies, 4 fine needle aspirates, 1 core needle biopsy, and 13 wedge excisions of lung were submitted fresh (unfixed) to our laboratory for evaluation. Among the 13 cases diagnosed as MALT lymphomas, B-cell monoclonality was established by identifying expression of a single immunoglobulin light chain on CD20 or CD19-positive cells in 12 cases. One case lacked expression of both light chains on B-cells. Of 11 lymphoma cases in which CD5 and CD10 surface antigens were assessed, no cases expressed CD10, and 1 case demonstrated weak CD5 expression. Nine of 10 cases studied were diploid and 1 case was hyperdiploid. All of the lymphomas displayed low (< or = 3%) S-phase fractions consistent with low grade processes. In 10 patients with short follow-up, none died of their disease and the majority had no evidence of lymphoma dissemination. In seven of the remaining eight cases, B-cells were polyclonal consistent with reactive processes. In one morphologically reactive case, flow cytometric analysis was unsuccessful because of poor cell viability. The pulmonary MALT lymphomas in this study represent a group of B-cell tumors with distinctive morphologic, immunophenotypic, and cell kinetic characteristics. Multi-parametric flow cytometry is useful for confirming B-cell monoclonality and illustrating an antigenic profile compatible with this diagnosis. Flow cytometry can be particularly helpful when working with small biopsies and cytologic samples with limited diagnostic

  2. Optimal background matching camouflage.

    PubMed

    Michalis, Constantine; Scott-Samuel, Nicholas E; Gibson, David P; Cuthill, Innes C

    2017-07-12

    Background matching is the most familiar and widespread camouflage strategy: avoiding detection by having a similar colour and pattern to the background. Optimizing background matching is straightforward in a homogeneous environment, or when the habitat has very distinct sub-types and there is divergent selection leading to polymorphism. However, most backgrounds have continuous variation in colour and texture, so what is the best solution? Not all samples of the background are likely to be equally inconspicuous, and laboratory experiments on birds and humans support this view. Theory suggests that the most probable background sample (in the statistical sense), at the size of the prey, would, on average, be the most cryptic. We present an analysis, based on realistic assumptions about low-level vision, that estimates the distribution of background colours and visual textures, and predicts the best camouflage. We present data from a field experiment that tests and supports our predictions, using artificial moth-like targets under bird predation. Additionally, we present analogous data for humans, under tightly controlled viewing conditions, searching for targets on a computer screen. These data show that, in the absence of predator learning, the best single camouflage pattern for heterogeneous backgrounds is the most probable sample. © 2017 The Authors.

  3. Radial accretion flows on static spherically symmetric black holes

    NASA Astrophysics Data System (ADS)

    Chaverra, Eliana; Sarbach, Olivier

    2015-08-01

    We analyze the steady radial accretion of matter into a nonrotating black hole. Neglecting the self-gravity of the accreting matter, we consider a rather general class of static, spherically symmetric and asymptotically flat background spacetimes with a regular horizon. In addition to the Schwarzschild metric, this class contains certain deformation of it, which could arise in alternative gravity theories or from solutions of the classical Einstein equations in the presence of external matter fields. Modeling the ambient matter surrounding the black hole by a relativistic perfect fluid, we reformulate the accretion problem as a dynamical system, and under rather general assumptions on the fluid equation of state, we determine the local and global qualitative behavior of its phase flow. Based on our analysis and generalizing previous work by Michel, we prove that for any given positive particle density number at infinity, there exists a unique radial, steady-state accretion flow which is regular at the horizon. We determine the physical parameters of the flow, including its accretion and compression rates, and discuss their dependency on the background metric.

  4. Particle Streak Velocimetry of Supersonic Nozzle Flows

    NASA Technical Reports Server (NTRS)

    Willits, J. D.; Pourpoint, T. L.

    2016-01-01

    A novel velocimetry technique to probe the exhaust flow of a laboratory scale combustor is being developed. The technique combines the advantages of standard particle velocimetry techniques and the ultra-fast imaging capabilities of a streak camera to probe high speed flows near continuously with improved spatial and velocity resolution. This "Particle Streak Velocimetry" technique tracks laser illuminated seed particles at up to 236 picosecond temporal resolution allowing time-resolved measurement of one-dimensional flows exceeding 2000 m/s as are found in rocket nozzles and many other applications. Developmental tests with cold nitrogen have been performed to validate and troubleshoot the technique with supersonic flows of much lower velocity and without background noise due to combusting flow. Flow velocities on the order of 500 m/s have been probed with titanium dioxide particles and a continuous-wave laser diode. Single frame images containing multiple streaks are analyzed to find the average slope of all incident particles corresponding to the centerline axial flow velocity. Long term objectives for these tests are correlation of specific impulse to theoretical combustion predictions and direct comparisons between candidate green fuels and the industry standard, monomethylhydrazine, each tested under identical conditions.

  5. Pulsed photoacoustic flow imaging with a handheld system

    NASA Astrophysics Data System (ADS)

    van den Berg, Pim J.; Daoudi, Khalid; Steenbergen, Wiendelt

    2016-02-01

    Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We propose flow imaging using a clinical photoacoustic system that is both handheld and portable. The system integrates a linear array with 7.5 MHz central frequency in combination with a high-repetition-rate diode laser to allow high-speed photoacoustic imaging-ideal for this application. This work shows the flow imaging performance of the system in vitro using microparticles. Both two-dimensional (2-D) flow images and quantitative flow velocities from 12 to 75 mm/s were obtained. In a transparent bulk medium, flow estimation showed standard errors of ˜7% the estimated speed; in the presence of tissue-realistic optical scattering, the error increased to 40% due to limited signal-to-noise ratio. In the future, photoacoustic flow imaging can potentially be performed in vivo using fluorophore-filled vesicles or with an improved setup on whole blood.

  6. C3: The Compositional Construction of Context. A New, More Effective and Efficient Way to Marshal Inferences from Background Knowledge

    DTIC Science & Technology

    2014-09-01

    quarter. Deep natural language understanding , efficient inference, pragmatics, background knowledge U U U SAR 4 Dr. David McDonald (781) 718-1964 C3...effective and efficient way to marshal inferences from background knowledge ’ N00014-13-1-0228 Dr. David McDonald Smart Information Flow Technologies, dba...for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data

  7. 2002 economic census : transportation : 2002 commodity flow survey : exports

    DOT National Transportation Integrated Search

    2005-03-01

    This report contains background information on the 2002 Commodity Flow Survey and then presents : detailed tabular results on shipment characteristics by mode of transportation, commodity, : and geography. In Appendix A, key characteristics of the 20...

  8. Induction of apoptosis in human promyelocytic leukemia HL-60 cells by Ampelopsis cantoniensis crude extract.

    PubMed

    Tan, Tzu-Wei; Tsai, Huei-Yann; Chen, Yuh-Fung; Chung, Jing-Gung

    2004-01-01

    The crude extract of Ampelopsis cantoniensis induced apoptosis in human promyelocytic leukemia HL-60 cells and this induction was investigated by flow cytometric analysis, DNA gel electrophoresis and poly (ADP-ribose) fluorescence staining. The results demonstrated that this extract induced dose-dependent cytotoxicity and apoptosis. The level of active caspase-3 was increased after treatment with the crude extract for 24 hours.

  9. New Advances in Molecular Therapy for Muscle Repair after Diseases and Injuries

    DTIC Science & Technology

    2011-01-01

    members of the broader scientific community . Statement of Work...negative for CD34 (1A). Nuclei were stained blue with Dapi. Scale bars, 100 µm. Flow cytometric analysis indicated percentage of cryopreserveded...muscle cells were also cytocentrifuged on glass slides and stained with antibodies to CD56, CD146, UEA-1(2Q, scale bars, 100 µm), and CD56/UEA-1

  10. Two-phase flow patterns in adiabatic and diabatic corrugated plate gaps

    NASA Astrophysics Data System (ADS)

    Polzin, A.-E.; Kabelac, S.; de Vries, B.

    2016-09-01

    Correlations for two-phase heat transfer and pressure drop can be improved considerably, when they are adapted to specific flow patterns. As plate heat exchangers find increasing application as evaporators and condensers, there is a need for flow pattern maps for corrugated plate gaps. This contribution presents experimental results on flow pattern investigations for such a plate heat exchanger background, using an adiabatic visualisation setup as well as a diabatic setup. Three characteristic flow patterns were observed in the considered range of two-phase flow: bubbly flow, film flow and slug flow. The occurrence of these flow patterns is a function of mass flux, void fraction, fluid properties and plate geometry. Two different plate geometries having a corrugation angle of 27° and 63°, respectively and two different fluids (water/air and R365mfc liquid/vapor) have been analysed. A flow pattern map using the momentum flux is presented.

  11. Background sources at PEP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynch, H.; Schwitters, R.F.; Toner, W.T.

    Important sources of background for PEP experiments are studied. Background particles originate from high-energy electrons and positrons which have been lost from stable orbits, ..gamma..-rays emitted by the primary beams through bremsstrahlung in the residual gas, and synchrotron radiation x-rays. The effect of these processes on the beam lifetime are calculated and estimates of background rates at the interaction region are given. Recommendations for the PEP design, aimed at minimizing background are presented. 7 figs., 4 tabs.

  12. Use of direct gradient analysis to uncover biological hypotheses in 16s survey data and beyond.

    PubMed

    Erb-Downward, John R; Sadighi Akha, Amir A; Wang, Juan; Shen, Ning; He, Bei; Martinez, Fernando J; Gyetko, Margaret R; Curtis, Jeffrey L; Huffnagle, Gary B

    2012-01-01

    This study investigated the use of direct gradient analysis of bacterial 16S pyrosequencing surveys to identify relevant bacterial community signals in the midst of a "noisy" background, and to facilitate hypothesis-testing both within and beyond the realm of ecological surveys. The results, utilizing 3 different real world data sets, demonstrate the utility of adding direct gradient analysis to any analysis that draws conclusions from indirect methods such as Principal Component Analysis (PCA) and Principal Coordinates Analysis (PCoA). Direct gradient analysis produces testable models, and can identify significant patterns in the midst of noisy data. Additionally, we demonstrate that direct gradient analysis can be used with other kinds of multivariate data sets, such as flow cytometric data, to identify differentially expressed populations. The results of this study demonstrate the utility of direct gradient analysis in microbial ecology and in other areas of research where large multivariate data sets are involved.

  13. Opium Induces Apoptosis in Jurkat Cells

    PubMed Central

    Igder, Somayeh; Asadikaram, Gholam Reza; Sheykholeslam, Farzaneh; Sayadi, Ahmad Reza; Mahmoodi, Mehdi; Kazemi Arababadi, Mohammad; Rasaee, Mohammad Javad

    2013-01-01

    Background The direct effect of some opioids on immune cells has been demonstrated. The aim of this study was to assess the apoptotic effect of opium on Jurkat T lymphocyte cells. Methods Different concentrations of opium (2.86 × 10-3 to 2.86 × 10-11 g/ml) were added to 24-well plates containing 5 × 105 Jurkat cells. Apoptotic events were assessed after 6, 24, and 72 hours by flow-cytometric detection of surface phosphatidylserine. Findings Significant differences in apoptosis of Jurkat cells were seen at 24 and 72 hours in different concentrations of opium (P < 0.05). After 72 hours, significant increase in necrosis of Jurkat cells was seen in opium concentration of 2.85 × 10-3 g/ml compared to cells without opium (control) (P < 0.05). Conclusion These results showed that opium directly increases apoptosis and necrosis of T lymphocytes. This effect may play a role in immune dysfunction in opium addicts. PMID:24494155

  14. Simulation of Mach Probes in Non-Uniform Magnetized Plasmas: the Influence of a Background Density Gradient

    NASA Astrophysics Data System (ADS)

    Haakonsen, Christian Bernt; Hutchinson, Ian H.

    2013-10-01

    Mach probes can be used to measure transverse flow in magnetized plasmas, but what they actually measure in strongly non-uniform plasmas has not been definitively established. A fluid treatment in previous work has suggested that the diamagnetic drifts associated with background density and temperature gradients affect transverse flow measurements, but detailed computational study is required to validate and elaborate on those results; it is really a kinetic problem, since the probe deforms and introduces voids in the ion and electron distribution functions. A new code, the Plasma-Object Simulator with Iterated Trajectories (POSIT) has been developed to self-consistently compute the steady-state six-dimensional ion and electron distribution functions in the perturbed plasma. Particle trajectories are integrated backwards in time to the domain boundary, where arbitrary background distribution functions can be specified. This allows POSIT to compute the ion and electron density at each node of its unstructured mesh, update the potential based on those densities, and then iterate until convergence. POSIT is used to study the impact of a background density gradient on transverse Mach probe measurements, and the results compared to the previous fluid theory. C.B. Haakonsen was supported in part by NSF/DOE Grant No. DE-FG02-06ER54512, and in part by an SCGF award administered by ORISE under DOE Contract No. DE-AC05-06OR23100.

  15. Contribution of flow cytometry to the diagnosis of gastric lymphomas in endoscopic biopsy specimens.

    PubMed

    Almasri, N M; Zaer, F S; Iturraspe, J A; Braylan, R C

    1997-07-01

    Gastric lymphomas seem to have unique clinical, pathologic, and immunophenotypic features that set them apart from nodal lymphomas. Microscopic examination of endoscopic biopsy specimens is the most frequent procedure used to diagnose gastric tumors, but it is very difficult, and sometimes impossible, to recognize lymphomas in endoscopic samples by histologic or even immunohistologic methods. Because most gastric lymphomas are of B-cell origin, we used flow cytometry to assess B-cell clonality in gastric biopsy specimens containing dense lymphocytic infiltrates thought to represent lymphoma. We prepared viable cell suspensions from unfixed specimens obtained from 29 consecutive patients who had a previous microscopic diagnosis of suspicious gastric lymphoid infiltrates. We performed immunophenotypic studies with multicolor flow cytometry, and we assessed clonality by examination of immunoglobulin (Ig) light-chain expression analyzed exclusively on B cells identified by anti-CD20 or CD19 antibodies. The mean number of cells recovered was 1.04 x 10(6), from an average of 5.5 gastric biopsy fragments per patient. In 26 of the 29 patients, the number of cells was adequate for analysis. We detected B-cell monoclonality in 16 cases, including 5 in which the percentage of clonal B cells was less than 5%. Of the 16 cases, only 8 could be diagnosed as lymphomas on morphologic grounds alone; the remaining 8 patients had either suspicious lymphoid infiltrates or chronic gastritis. The three cases with an insufficient number of cells were considered non-neoplastic either on histologic grounds alone or in conjunction with Southern analysis of Ig genes. We conclude that flow cytometric immunophenotypic analysis of freshly prepared cell suspensions obtained from endoscopic biopsy specimens can be used to evaluate gastric lymphocytic infiltrates. Specifically, the analysis of surface Ig light-chain expression on B cells distinguishes between monoclonal (lymphoma) and polyclonal

  16. The combination of kinetic and flow cytometric semen parameters as a tool to predict fertility in cryopreserved bull semen.

    PubMed

    Gliozzi, T M; Turri, F; Manes, S; Cassinelli, C; Pizzi, F

    2017-11-01

    Within recent years, there has been growing interest in the prediction of bull fertility through in vitro assessment of semen quality. A model for fertility prediction based on early evaluation of semen quality parameters, to exclude sires with potentially low fertility from breeding programs, would therefore be useful. The aim of the present study was to identify the most suitable parameters that would provide reliable prediction of fertility. Frozen semen from 18 Italian Holstein-Friesian proven bulls was analyzed using computer-assisted semen analysis (CASA) (motility and kinetic parameters) and flow cytometry (FCM) (viability, acrosomal integrity, mitochondrial function, lipid peroxidation, plasma membrane stability and DNA integrity). Bulls were divided into two groups (low and high fertility) based on the estimated relative conception rate (ERCR). Significant differences were found between fertility groups for total motility, active cells, straightness, linearity, viability and percentage of DNA fragmented sperm. Correlations were observed between ERCR and some kinetic parameters, and membrane instability and some DNA integrity indicators. In order to define a model with high relation between semen quality parameters and ERCR, backward stepwise multiple regression analysis was applied. Thus, we obtained a prediction model that explained almost half (R 2=0.47, P<0.05) of the variation in the conception rate and included nine variables: five kinetic parameters measured by CASA (total motility, active cells, beat cross frequency, curvilinear velocity and amplitude of lateral head displacement) and four parameters related to DNA integrity evaluated by FCM (degree of chromatin structure abnormality Alpha-T, extent of chromatin structure abnormality (Alpha-T standard deviation), percentage of DNA fragmented sperm and percentage of sperm with high green fluorescence representative of immature cells). A significant relationship (R 2=0.84, P<0.05) was observed between

  17. Detection of early changes in lung cell cytology by flow-systems analysis techniques. Progress report, January 1-June 30, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steinkamp, J.A.; Wilson, J.S.; Svitra, Z.V.

    1979-08-01

    This report summarizes results of ongoing experiments designed to develop automated flow-analysis assay methods for discerning damage to exfoliated respiratory tract cells in model test animals exposed by inhalation to physical and chemical agents associated with the production of synthetic fuels from oil shale and coal, the specific goal being the determination of atypical changes in exposed alveolar macrophages and epithelial cells. Animals were exposed to oil shale particles (raw and spent), silica, and polystyrene latex spheres via intratracheal instillation. Respiratory tract cells were obtained by lavaging the lungs with normal saline, stained with mithramycin for DNA content, and analyzedmore » using flow cytometric analysis methods. In addition to measuring DNA content, differential and total cell counts were made on all samples analyzed. DNA content frequency distribution histograms and cytology showed definite atypical changes resulting from exposure to shale and silica particulates when compared to the controls. To continue development of fluorescence staining methods for measuring intracellular enzymes in alveolar macrophages, studies were initiated for determining ..beta..-glucuronidase using naphthol AS-BI-..beta..-d-glucuronic acid as a fluorogenic substrate. As this new technology becomes adapted to analyzing pulmonary macrophages and epithelial cells, the measurement of physical and biochemical properties as a function of exposure to particulate and gaseous toxic agents related to the production of synthetic fuels will be increased. This analytical approach is designed to assist in the establishment of future guideline for estimating the risks to exposed humans.« less

  18. Retroreflective Background Oriented Schlieren Imaging Results from the NASA Plume/Shock Interaction Test

    NASA Technical Reports Server (NTRS)

    Smith, Nathanial T.; Durston, Donald A.; Heineck, James T.

    2017-01-01

    In support of NASA's Commercial Supersonics Technology (CST) project, a test was conducted in the 9-by-7 ft. supersonic section of the NASA Ames Unitary Plan Wind Tunnel (UPWT). The tests were designed to study the interaction of shocks with a supersonic jet characteristic of those that may occur on a commercial supersonic aircraft. Multiple shock generating geometries were tested to examine the interaction dynamics as they pertain to sonic boom mitigation. An integral part of the analyses of these interactions are the interpretation of the data generated from the retroreflective Background Oriented Schlieren (RBOS) imaging technique employed for this test. The regularization- based optical flow methodology used to generate these data is described. Sample results are compared to those using normalized cross-correlation. The reduced noise, additional feature detail, and fewer false artifacts provided by the optical flow technique produced clearer time-averaged images, allowing for better interpretation of the underlying flow phenomena. These images, coupled with pressure signatures in the near field, are used to provide an overview of the detailed interaction flowfields.

  19. Hydrodynamic Capture of Particles by Micro-swimmers under Hele-Shaw Flows

    NASA Astrophysics Data System (ADS)

    Mishler, Grant; Tsang, Alan Cheng Hou; Pak, On Shun

    2017-11-01

    We explore a hydrodynamic capture mechanism of a driven particle by a micro-swimmer in confined microfluidic environments with an idealized model. The capture is mediated by the hydrodynamic interactions between the micro-swimmer, the driven particle, and the background flow. This capture mechanism relies on the existence of attractive stable equilibrium configurations between the driven particle and the micro-swimmer, which occurs when the background flow is larger than a certain critical threshold. Dynamics and stability of capture and non-capture events will be discussed. This study may have potential applications in the study of capture and delivery of therapeutic payloads by micro-swimmers as well as particle self-assembly under confinements.

  20. A continuous sampler with background suppression for monitoring alpha-emitting aerosol particles.

    PubMed

    McFarland, A R; Rodgers, J C; Ortiz, C A; Moore, M E

    1992-05-01

    A continuous air monitor has been developed that includes provisions for improving the detection of alpha-emitting aerosol particles in the presence of radon/thoron progeny that are unattached to ambient aerosol particles. Wind tunnel tests show that 80% of 10-microns aerodynamic equivalent diameter particles penetrate the flow system from the ambient air to the collection filter when the flow rate is 57 L min-1 (2 cfm) and the wind speed is 1 m s-1. Uniformity of aerosol collection on the filter, as characterized by the coefficient of variation of the areal density deposits, is less than 15% for 10-microns aerodynamic-equivalent-diameter aerosol particles. Tests with unattached radon daughters in a flow-through chamber showed that approximately 99% of the 218Po was removed by an inlet screen that is designed to collect radon daughters that are in the size range of molecular clusters. The inlet screen offers the opportunity to improve the signal-to-noise ratio of energy spectra in the regions of interest (subranges of the energy spectrum) of transuranic elements and thereby enhance the performance of background compensation algorithms.

  1. Magnetohydrodynamic stability of stochastically driven accretion flows.

    PubMed

    Nath, Sujit Kumar; Mukhopadhyay, Banibrata; Chattopadhyay, Amit K

    2013-07-01

    We investigate the evolution of magnetohydrodynamic (or hydromagnetic as coined by Chandrasekhar) perturbations in the presence of stochastic noise in rotating shear flows. The particular emphasis is the flows whose angular velocity decreases but specific angular momentum increases with increasing radial coordinate. Such flows, however, are Rayleigh stable but must be turbulent in order to explain astrophysical observed data and, hence, reveal a mismatch between the linear theory and observations and experiments. The mismatch seems to have been resolved, at least in certain regimes, in the presence of a weak magnetic field, revealing magnetorotational instability. The present work explores the effects of stochastic noise on such magnetohydrodynamic flows, in order to resolve the above mismatch generically for the hot flows. We essentially concentrate on a small section of such a flow which is nothing but a plane shear flow supplemented by the Coriolis effect, mimicking a small section of an astrophysical accretion disk around a compact object. It is found that such stochastically driven flows exhibit large temporal and spatial autocorrelations and cross-correlations of perturbation and, hence, large energy dissipations of perturbation, which generate instability. Interestingly, autocorrelations and cross-correlations appear independent of background angular velocity profiles, which are Rayleigh stable, indicating their universality. This work initiates our attempt to understand the evolution of three-dimensional hydromagnetic perturbations in rotating shear flows in the presence of stochastic noise.

  2. Protein expression pattern of PAWP in bull spermatozoa is associated with sperm quality and fertility following artificial insemination.

    PubMed

    Kennedy, Chelsey E; Krieger, Kari Beth; Sutovsky, Miriam; Xu, Wei; Vargovič, Peter; Didion, Bradley A; Ellersieck, Mark R; Hennessy, Madison E; Verstegen, John; Oko, Richard; Sutovsky, Peter

    2014-05-01

    Post-acrosomal WW-domain binding protein (PAWP) is a signaling molecule located in the post-acrosomal sheath (PAS) of mammalian spermatozoa. We hypothesized that the proper integration of PAWP in the sperm PAS is reflective of bull-sperm quality and fertility. Cryopreserved semen samples from 298 sires of acceptable, but varied, fertility used in artificial insemination services were analyzed using immunofluorescence microscopy and flow cytometry for PAWP protein. In normal spermatozoa, PAWP fluorescence formed a regular band around the proximal PAS. Anomalies of PAWP labeling in defective spermatozoa were reflected in flow cytometry by varied intensities of PAWP-induced fluorescence. Distinct sperm phenotypes were also identified, including morphologically normal and some defective spermatozoa with moderate levels of PAWP; grossly defective spermatozoa with low/no PAWP; and defective spermatozoa with high PAWP. Analysis by ImageStream flow cytometry confirmed the prevalence of abnormal sperm phenotypes in the spermatozoa with abnormal PAWP content. Live/dead staining and video recording showed that some abnormal spermatozoa are viable and capable of progressive motility. Conventional flow-cytometric measurements of PAWP correlated significantly with semen quality and fertility parameters that reflect the sires' artificial insemination fertility, including secondary sperm morphology, conception rate, non-return rate, and residual value. A multiplex, flow-cytometric test detecting PAWP, aggresomes (ubiquitinated protein aggregates), and acrosomal integrity (peanut-agglutinin-lectin labeling) had a predictive value for conception rate, as demonstrated by step-wise regression analysis. We conclude that PAWP correlates with semen/fertility parameters used in the cattle artificial insemination industry, making PAWP a potential biomarker of bull fertility. © 2014 Wiley Periodicals, Inc.

  3. The Uncertainty of Local Background Magnetic Field Orientation in Anisotropic Plasma Turbulence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerick, F.; Saur, J.; Papen, M. von, E-mail: felix.gerick@uni-koeln.de

    In order to resolve and characterize anisotropy in turbulent plasma flows, a proper estimation of the background magnetic field is crucially important. Various approaches to calculating the background magnetic field, ranging from local to globally averaged fields, are commonly used in the analysis of turbulent data. We investigate how the uncertainty in the orientation of a scale-dependent background magnetic field influences the ability to resolve anisotropy. Therefore, we introduce a quantitative measure, the angle uncertainty, that characterizes the uncertainty of the orientation of the background magnetic field that turbulent structures are exposed to. The angle uncertainty can be used asmore » a condition to estimate the ability to resolve anisotropy with certain accuracy. We apply our description to resolve the spectral anisotropy in fast solar wind data. We show that, if the angle uncertainty grows too large, the power of the turbulent fluctuations is attributed to false local magnetic field angles, which may lead to an incorrect estimation of the spectral indices. In our results, an apparent robustness of the spectral anisotropy to false local magnetic field angles is observed, which can be explained by a stronger increase of power for lower frequencies when the scale of the local magnetic field is increased. The frequency-dependent angle uncertainty is a measure that can be applied to any turbulent system.« less

  4. Kolmogorov-Smirnov statistical test for analysis of ZAP-70 expression in B-CLL, compared with quantitative PCR and IgV(H) mutation status.

    PubMed

    Van Bockstaele, Femke; Janssens, Ann; Piette, Anne; Callewaert, Filip; Pede, Valerie; Offner, Fritz; Verhasselt, Bruno; Philippé, Jan

    2006-07-15

    ZAP-70 has been proposed as a surrogate marker for immunoglobulin heavy-chain variable region (IgV(H)) mutation status, which is known as a prognostic marker in B-cell chronic lymphocytic leukemia (CLL). The flow cytometric analysis of ZAP-70 suffers from difficulties in standardization and interpretation. We applied the Kolmogorov-Smirnov (KS) statistical test to make analysis more straightforward. We examined ZAP-70 expression by flow cytometry in 53 patients with CLL. Analysis was performed as initially described by Crespo et al. (New England J Med 2003; 348:1764-1775) and alternatively by application of the KS statistical test comparing T cells with B cells. Receiver-operating-characteristics (ROC)-curve analyses were performed to determine the optimal cut-off values for ZAP-70 measured by the two approaches. ZAP-70 protein expression was compared with ZAP-70 mRNA expression measured by a quantitative PCR (qPCR) and with the IgV(H) mutation status. Both flow cytometric analyses correlated well with the molecular technique and proved to be of equal value in predicting the IgV(H) mutation status. Applying the KS test is reproducible, simple, straightforward, and overcomes a number of difficulties encountered in the Crespo-method. The KS statistical test is an essential part of the software delivered with modern routine analytical flow cytometers and is well suited for analysis of ZAP-70 expression in CLL. (c) 2006 International Society for Analytical Cytology.

  5. An Improved Flow Cytometry Method For Precise Quantitation Of Natural-Killer Cell Activity

    NASA Technical Reports Server (NTRS)

    Crucian, Brian; Nehlsen-Cannarella, Sandra; Sams, Clarence

    2006-01-01

    The ability to assess NK cell cytotoxicity using flow cytometry has been previously described and can serve as a powerful tool to evaluate effector immune function in the clinical setting. Previous methods used membrane permeable dyes to identify target cells. The use of these dyes requires great care to achieve optimal staining and results in a broad spectral emission that can make multicolor cytometry difficult. Previous methods have also used negative staining (the elimination of target cells) to identify effector cells. This makes a precise quantitation of effector NK cells impossible due to the interfering presence of T and B lymphocytes, and the data highly subjective to the variable levels of NK cells normally found in human peripheral blood. In this study an improved version of the standard flow cytometry assay for NK activity is described that has several advantages of previous methods. Fluorescent antibody staining (CD45FITC) is used to positively identify target cells in place of membranepermeable dyes. Fluorescent antibody staining of target cells is less labor intensive and more easily reproducible than membrane dyes. NK cells (true effector lymphocytes) are also positively identified by fluorescent antibody staining (CD56PE) allowing a simultaneous absolute count assessment of both NK cells and target cells. Dead cells are identified by membrane disruption using the DNA intercalating dye PI. Using this method, an exact NK:target ratio may be determined for each assessment, including quantitation of NK target complexes. Backimmunoscatter gating may be used to track live vs. dead Target cells via scatter properties. If desired, NK activity may then be normalized to standardized ratios for clinical comparisons between patients, making the determination of PBMC counts or NK cell percentages prior to testing unnecessary. This method provides an exact cytometric determination of NK activity that highly reproducible and may be suitable for routine use in the

  6. Beam-modulation methods in quantitative and flow-visualization holographic interferometry

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.

    1986-01-01

    Heterodyne holographic interferometry and time-average holography with a frequency shifted reference beam are discussed. Both methods will be used for the measurement and visualization of internal transonic flows where the target facility is a flutter cascade. The background and experimental requirements for both methods are reviewed. Measurements using heterodyne holographic interferometry are presented. The performance of the laser required for time-average holography of time-varying transonic flows is discussed.

  7. Mechanism of antiproliferative action of a new d-secoestrone-triazole derivative in cervical cancer cells and its effect on cancer cell motility.

    PubMed

    Bózsity, Noémi; Minorics, Renáta; Szabó, Johanna; Mernyák, Erzsébet; Schneider, Gyula; Wölfling, János; Wang, Hui-Chun; Wu, Chin-Chung; Ocsovszki, Imre; Zupkó, István

    2017-01-01

    Cervical cancer is the fourth most frequently diagnosed tumor and the fourth leading cause of cancer death in females worldwide. Cervical cancer is predominantly related with human papilloma virus (HPV) infection, with the most oncogenic types being HPV-18 and -16. Our previous studies demonstrated that some d-secoestrone derivatives exert pronounced antiproliferative activity. The aim of the current investigation was to characterize the mechanism of action of d-secoestrone-triazole (D-SET) on three cervical cancer cell lines with different pathological backgrounds. The growth-inhibitory effects of D-SET were determined by a standard MTT assay. We have found that D-SET exerts a pronounced growth-inhibitory effect on HPV 18-positive HeLa and HPV-negative C-33 A cells, but it has no substantial inhibitory activity on HPV 16-positive SiHa or on intact fibroblast MRC-5 cell lines. After 24h incubation, cells showed the morphological and biochemical signs of apoptosis determined by fluorescent double staining, flow cytometry and caspase-3 activity assay. Besides the elevation of the ratio of cells in the subG1 phase, flow cytometric analysis revealed a cell cycle arrest at G2/M in both HeLa and C-33 A cell lines. To distinguish the G2/M cell population immunocytochemical flow cytometric analysis was performed on HeLa cells. The results show that D-SET significantly increases the ratio of phosphorylated histone H3, indicating cell accumulation in the M phase. Additionally, D-SET significantly increased the maximum rate of microtube formation measured by an in vitro tubulin polymerization assay. Besides its direct antiproliferative activity, the antimigratory property of D-SET has been investigated. Our results demonstrate that D-SET significantly inhibits the migration and invasion of HeLa cells after 24h incubation. These results suggests that D-SET is a potent antiproliferative agent against HPV 16+ and HPV-negative cervical cancer cell lines, with an efficacious

  8. Evaluation of blood flow distribution asymmetry and vascular geometry in patients with Fontan circulation using 4-D flow MRI

    PubMed Central

    Jarvis, Kelly; Schnell, Susanne; Barker, Alex J.; Garcia, Julio; Lorenz, Ramona; Rose, Michael; Chowdhary, Varun; Carr, James; Robinson, Joshua D.; Rigsby, Cynthia K.; Markl, Michael

    2016-01-01

    Background Asymmetrical caval to pulmonary blood flow is suspected to cause complications in patients with Fontan circulation. The aim of this study was to test the feasibility of 4-D flow MRI for characterizing the relationship between 3-D blood flow distribution and vascular geometry. Objective We hypothesized that both flow distribution and geometry can be calculated with low interobserver variability and will detect a direct relationship between flow distribution and Fontan geometry. Materials and methods Four-dimensional flow MRI was acquired in 10 Fontan patients (age: 16±4 years [mean ± standard deviation; range 9–21 years]). The Fontan connection was isolated by 3-D segmentation to evaluate flow distribution from the inferior vena cava (IVC) and superior vena cava (SVC) to the left and right pulmonary arteries (LPA, RPA) and to characterize geometry (cross-sectional area, caval offset, vessel angle). Results Flow distribution results indicated SVC flow tended toward the RPA while IVC flow was more evenly distributed (SVC to RPA: 78%±28 [9–100], IVC to LPA: 54%±28 [4–98]). There was a significant relationship between pulmonary artery cross-sectional area and flow distribution (IVC to RPA: R2=0.50, P=0.02; SVC to LPA: R2=0.81, P=0.0004). Good agreement was found between observers and for flow distribution when compared to net flow values. Conclusion Four-dimensional (4-D) flow MRI was able to detect relationships between flow distribution and vessel geometry. Future studies are warranted to investigate the potential of patient specific hemodynamic analysis to improve diagnostic capability. PMID:27350377

  9. Novel whole blood assay for phenotyping platelet reactivity in mice identifies ICAM-1 as a mediator of platelet-monocyte interaction

    PubMed Central

    Kirkby, Nicholas S.; Chan, Melissa V.; Finsterbusch, Michaela; Hogg, Nancy; Nourshargh, Sussan; Warner, Timothy D.

    2015-01-01

    Testing of platelet function is central to the cardiovascular phenotyping of genetically modified mice. Traditional platelet function tests have been developed primarily for testing human samples and the volumes required make them highly unsuitable for the testing of mouse platelets. This limits research in this area. To address this problem, we have developed a miniaturized whole blood aggregometry assay, based on a readily accessible 96-well plate format coupled with quantification of single platelet depletion by flow cytometric analysis. Using this approach, we observed a concentration-dependent loss of single platelets in blood exposed to arachidonic acid, collagen, U46619 or protease activated receptor 4 activating peptide. This loss was sensitive to well-established antiplatelet agents and genetic manipulation of platelet activation pathways. Observations were more deeply analyzed by flow cytometric imaging, confocal imaging, and measurement of platelet releasates. Phenotypic analysis of the reactivity of platelets taken from mice lacking intercellular adhesion molecule (ICAM)-1 identified a marked decrease in fibrinogen-dependent platelet-monocyte interactions, especially under inflammatory conditions. Such findings exemplify the value of screening platelet phenotypes of genetically modified mice and shed further light upon the roles and interactions of platelets in inflammation. PMID:26215112

  10. Mitomycin C-induced apoptosis in cultured human Tenon's capsule fibroblasts.

    PubMed

    Kim, J W; Kim, S K; Song, I H; Kim, I T

    1999-06-01

    To investigate the mitomycin C-induced apoptotic cell death of fibroblasts, the primarily cultured human Tenon's capsule fibroblasts were exposed to a clinically used dosage of 0.4 mg/ml of mitomycin C for 5 minutes. TUNEL (TdT-mediated dUTP-biotin nick end labeling) assay and electron microscopic studies were performed to determine the extent of mitomycin C-induced apoptosis. A flow cytometric study was performed to quantify the apoptotic cell population over time. The TUNEL stains were positive and electron microscopy showed features of apoptotic cell death in some fibroblasts 3 and 5 days after treatment. Flow cytometric analysis using Annexin V-propidium iodide double staining detected apoptotic cells 3 days after treatment. These apoptotic cell populations increased at 4 days and were sustained for one week. This study revealed that the clinical effects of mitomycin C on fibroblasts may be mediated not only by antiproliferative but also apoptotic cell death to some degree. Therefore, the apoptotic cell death of fibroblasts induced by mitomycin C should be considered to properly understand the mechanism of wound healing after trabeculectomy with adjunctive mitomycin C.

  11. Identification of early B cell precursors (stage 1 and 2 hematogones) in the peripheral blood.

    PubMed

    Kurzer, Jason H; Weinberg, Olga K

    2018-05-25

    Differentiating malignant B-lymphoblasts from early benign B cell precursors (hematogones) is a vital component of the diagnosis of B-lymphoblastic leukaemia. It has been previously reported that only late-stage B cell precursors circulate in the peripheral blood. Consequently, flow cytometric detection of cells with immunophenotypic findings similar to earlier stage precursors in the peripheral blood justifiably raises concern for involvement by B-lymphoblastic leukaemia. We report here, however, that benign early B cell precursors can indeed be detected in the peripheral blood, thus complicating the interpretation of flow cytometric findings derived from these sample types. A retrospective search of our collective databases identified 13 cases containing circulating early stage B cell precursors. The patients ranged in age from 15 days to 85 years old. All positive cases demonstrated that the earlier B cell precursors were associated with later stage precursors, a finding that could help differentiate these cells from B-lymphoblastic leukaemia. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Fertility and flow cytometry study of frozen-thawed sperm in cryopreservation medium supplemented with soybean lecithin.

    PubMed

    Masoudi, R; Sharafi, M; Zareh Shahneh, A; Towhidi, A; Kohram, H; Esmaeili, V; Shahverdi, A; Davachi, N Dadashpour

    2016-08-01

    Semen cryopreservation can provide genetic resources for a large number of females from a small number of superior males. Optimization of cryopreservation media to achieve the highest quality of post-thaw semen is crucial. Soybean lecithin has evaluated as a plant-based cryoprotectant for substitution of egg yolk in ram semen extender. Flow cytometric and fertility assessments were applied following cryopreservation procedure in two experimental groups (SL group: extender containing 1% w/v soybean lecithin and EY group: extender containing 20% v/v egg yolk). The higher percentage of live sperm and the lower percentage of dead sperm were obtained in SL (47.66 ± 1.38, 52.33 ± 1.69, respectively) extender compared to EY (41.16 ± 1.38, 58.83 ± 1.69). For motion characteristics, plasma membrane integrity, acrosome integrity and mitochondria activity, no significant difference was observed between SL and EY extenders. In artificial insemination experiment, there was no significant difference in pregnancy rate, lambing rate and twining rate between SL and EY extenders. It can be concluded that SL extender can be an efficient alternative extender to preserve ram sperm during cryopreservation procedure without adverse effects. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. The role of zonal flows in disc gravito-turbulence

    NASA Astrophysics Data System (ADS)

    Vanon, R.

    2018-07-01

    The work presented here focuses on the role of zonal flows in the self-sustenance of gravito-turbulence in accretion discs. The numerical analysis is conducted using a bespoke pseudo-spectral code in fully compressible, non-linear conditions. The disc in question, which is modelled using the shearing sheet approximation, is assumed to be self-gravitating, viscous, and thermally diffusive; a constant cooling time-scale is also considered. Zonal flows are found to emerge at the onset of gravito-turbulence and they remain closely linked to the turbulent state. A cycle of zonal flow formation and destruction is established, mediated by a slow mode instability (which allows zonal flows to grow) and a non-axisymmetric instability (which disrupts the zonal flow), which is found to repeat numerous times. It is in fact the disruptive action of the non-axisymmetric instability to form new leading and trailing shearing waves, allowing energy to be extracted from the background flow and ensuring the self-sustenance of the gravito-turbulent regime.

  14. The role of zonal flows in disc gravito-turbulence

    NASA Astrophysics Data System (ADS)

    Vanon, R.

    2018-04-01

    The work presented here focuses on the role of zonal flows in the self-sustenance of gravito-turbulence in accretion discs. The numerical analysis is conducted using a bespoke pseudo-spectral code in fully compressible, non-linear conditions. The disc in question, which is modelled using the shearing sheet approximation, is assumed to be self-gravitating, viscous, and thermally diffusive; a constant cooling timescale is also considered. Zonal flows are found to emerge at the onset of gravito-turbulence and they remain closely linked to the turbulent state. A cycle of zonal flow formation and destruction is established, mediated by a slow mode instability (which allows zonal flows to grow) and a non-axisymmetric instability (which disrupts the zonal flow), which is found to repeat numerous times. It is in fact the disruptive action of the non-axisymmetric instability to form new leading and trailing shearing waves, allowing energy to be extracted from the background flow and ensuring the self-sustenance of the gravito-turbulent regime.

  15. Demographic history and gene flow during silkworm domestication

    PubMed Central

    2014-01-01

    Background Gene flow plays an important role in domestication history of domesticated species. However, little is known about the demographic history of domesticated silkworm involving gene flow with its wild relative. Results In this study, four model-based evolutionary scenarios to describe the demographic history of B. mori were hypothesized. Using Approximate Bayesian Computation method and DNA sequence data from 29 nuclear loci, we found that the gene flow at bottleneck model is the most likely scenario for silkworm domestication. The starting time of silkworm domestication was estimated to be approximate 7,500 years ago; the time of domestication termination was 3,984 years ago. Using coalescent simulation analysis, we also found that bi-directional gene flow occurred during silkworm domestication. Conclusions Estimates of silkworm domestication time are nearly consistent with the archeological evidence and our previous results. Importantly, we found that the bi-directional gene flow might occur during silkworm domestication. Our findings add a dimension to highlight the important role of gene flow in domestication of crops and animals. PMID:25123546

  16. A Streamline-Upwind Petrov-Galerkin Finite Element Scheme for Non-Ionized Hypersonic Flows in Thermochemical Nonequilibrium

    NASA Technical Reports Server (NTRS)

    Kirk, Benjamin S.; Bova, Stephen W.; Bond, Ryan B.

    2011-01-01

    Presentation topics include background and motivation; physical modeling including governing equations and thermochemistry; finite element formulation; results of inviscid thermal nonequilibrium chemically reacting flow and viscous thermal equilibrium chemical reacting flow; and near-term effort.

  17. Zonal Flows and Turbulence in Fluids and Plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Jeffrey

    2014-09-01

    In geophysical and plasma contexts, zonal flows are well known to arise out of turbulence. We elucidate the transition from statistically homogeneous turbulence without zonal flows to statistically inhomogeneous turbulence with steady zonal flows. Starting from the Hasegawa--Mima equation, we employ both the quasilinear approximation and a statistical average, which retains a great deal of the qualitative behavior of the full system. Within the resulting framework known as CE2, we extend recent understanding of the symmetry-breaking `zonostrophic instability'. Zonostrophic instability can be understood in a very general way as the instability of some turbulent background spectrum to a zonally symmetricmore » coherent mode. As a special case, the background spectrum can consist of only a single mode. We find that in this case the dispersion relation of zonostrophic instability from the CE2 formalism reduces exactly to that of the 4-mode truncation of generalized modulational instability. We then show that zonal flows constitute pattern formation amid a turbulent bath. Zonostrophic instability is an example of a Type Is instability of pattern-forming systems. The broken symmetry is statistical homogeneity. Near the bifurcation point, the slow dynamics of CE2 are governed by a well-known amplitude equation, the real Ginzburg-Landau equation. The important features of this amplitude equation, and therefore of the CE2 system, are multiple. First, the zonal flow wavelength is not unique. In an idealized, infinite system, there is a continuous band of zonal flow wavelengths that allow a nonlinear equilibrium. Second, of these wavelengths, only those within a smaller subband are stable. Unstable wavelengths must evolve to reach a stable wavelength; this process manifests as merging jets. These behaviors are shown numerically to hold in the CE2 system, and we calculate a stability diagram. The stability diagram is in agreement with direct numerical simulations of the

  18. Zonal flows and turbulence in fluids and plasmas

    NASA Astrophysics Data System (ADS)

    Parker, Jeffrey Bok-Cheung

    In geophysical and plasma contexts, zonal flows are well known to arise out of turbulence. We elucidate the transition from statistically homogeneous turbulence without zonal flows to statistically inhomogeneous turbulence with steady zonal flows. Starting from the Hasegawa--Mima equation, we employ both the quasilinear approximation and a statistical average, which retains a great deal of the qualitative behavior of the full system. Within the resulting framework known as CE2, we extend recent understanding of the symmetry-breaking 'zonostrophic instability'. Zonostrophic instability can be understood in a very general way as the instability of some turbulent background spectrum to a zonally symmetric coherent mode. As a special case, the background spectrum can consist of only a single mode. We find that in this case the dispersion relation of zonostrophic instability from the CE2 formalism reduces exactly to that of the 4-mode truncation of generalized modulational instability. We then show that zonal flows constitute pattern formation amid a turbulent bath. Zonostrophic instability is an example of a Type I s instability of pattern-forming systems. The broken symmetry is statistical homogeneity. Near the bifurcation point, the slow dynamics of CE2 are governed by a well-known amplitude equation, the real Ginzburg-Landau equation. The important features of this amplitude equation, and therefore of the CE2 system, are multiple. First, the zonal flow wavelength is not unique. In an idealized, infinite system, there is a continuous band of zonal flow wavelengths that allow a nonlinear equilibrium. Second, of these wavelengths, only those within a smaller subband are stable. Unstable wavelengths must evolve to reach a stable wavelength; this process manifests as merging jets. These behaviors are shown numerically to hold in the CE2 system, and we calculate a stability diagram. The stability diagram is in agreement with direct numerical simulations of the quasilinear

  19. Comparative analysis of cell wall surface glycan expression in Candida albicans and Saccharomyces cerevisiae yeasts by flow cytometry.

    PubMed

    Martínez-Esparza, M; Sarazin, A; Jouy, N; Poulain, D; Jouault, T

    2006-07-31

    The yeast Candida albicans is an opportunistic pathogen, part of the normal human microbial flora that causes infections in immunocompromised individuals with a high morbidity and mortality levels. Recognition of yeasts by host cells is based on components of the yeast cell wall, which are considered part of its virulence attributes. Cell wall glycans play an important role in the continuous interchange that regulates the balance between saprophytism and parasitism, and also between resistance and infection. Some of these molecular entities are expressed both by the pathogenic yeast C. albicans and by Saccharomyces cerevisiae, a related non-pathogenic yeast, involving similar molecular mechanisms and receptors for recognition. In this work we have exploited flow cytometry methods for probing surface glycans of the yeasts. We compared glycan expression by C. albicans and by S. cerevisiae, and studied the effect of culture conditions. Our results show that the expression levels of alpha- and beta-linked mannosides as well as beta-glucans can be successfully evaluated by flow cytometry methods using different antibodies independent of agglutination reactions. We also found that the surface expression pattern of beta-mannosides detected by monoclonal or polyclonal antibodies are differently modulated during the growth course. These data indicate that the yeast beta-mannosides exposed on mannoproteins and/or phospholipomannan are increased in stationary phase, whereas those linked to mannan are not affected by the yeast growth phase. The cytometric method described here represents a useful tool to investigate to what extent C. albicans is able to regulate its glycan surface expression and therefore modify its virulence properties.

  20. Holography as a highly efficient renormalization group flow. I. Rephrasing gravity

    NASA Astrophysics Data System (ADS)

    Behr, Nicolas; Kuperstein, Stanislav; Mukhopadhyay, Ayan

    2016-07-01

    We investigate how the holographic correspondence can be reformulated as a generalization of Wilsonian renormalization group (RG) flow in a strongly interacting large-N quantum field theory. We first define a highly efficient RG flow as one in which the Ward identities related to local conservation of energy, momentum and charges preserve the same form at each scale. To achieve this, it is necessary to redefine the background metric and external sources at each scale as functionals of the effective single-trace operators. These redefinitions also absorb the contributions of the multitrace operators to these effective Ward identities. Thus, the background metric and external sources become effectively dynamical, reproducing the dual classical gravity equations in one higher dimension. Here, we focus on reconstructing the pure gravity sector as a highly efficient RG flow of the energy-momentum tensor operator, leaving the explicit constructive field theory approach for generating such RG flows to the second part of the work. We show that special symmetries of the highly efficient RG flows carry information through which we can decode the gauge fixing of bulk diffeomorphisms in the corresponding gravity equations. We also show that the highly efficient RG flow which reproduces a given classical gravity theory in a given gauge is unique provided the endpoint can be transformed to a nonrelativistic fixed point with a finite number of parameters under a universal rescaling. The results obtained here are used in the second part of this work, where we do an explicit field-theoretic construction of the RG flow and obtain the dual classical gravity theory.

  1. Pancreatic islet blood flow and its measurement

    PubMed Central

    Jansson, Leif; Barbu, Andreea; Bodin, Birgitta; Drott, Carl Johan; Espes, Daniel; Gao, Xiang; Grapensparr, Liza; Källskog, Örjan; Lau, Joey; Liljebäck, Hanna; Palm, Fredrik; Quach, My; Sandberg, Monica; Strömberg, Victoria; Ullsten, Sara; Carlsson, Per-Ola

    2016-01-01

    Pancreatic islets are richly vascularized, and islet blood vessels are uniquely adapted to maintain and support the internal milieu of the islets favoring normal endocrine function. Islet blood flow is normally very high compared with that to the exocrine pancreas and is autonomously regulated through complex interactions between the nervous system, metabolites from insulin secreting β-cells, endothelium-derived mediators, and hormones. The islet blood flow is normally coupled to the needs for insulin release and is usually disturbed during glucose intolerance and overt diabetes. The present review provides a brief background on islet vascular function and especially focuses on available techniques to measure islet blood perfusion. The gold standard for islet blood flow measurements in experimental animals is the microsphere technique, and its advantages and disadvantages will be discussed. In humans there are still no methods to measure islet blood flow selectively, but new developments in radiological techniques hold great hopes for the future. PMID:27124642

  2. Backgrounds in Language.

    ERIC Educational Resources Information Center

    Maxwell, John C.; Long, Barbara K.

    "Backgrounds in Language," a field-tested inservice course designed for use by groups of 15 or 25 language arts teachers, provides the subject matter background teachers need to make informed decisions about what curriculum materials to use in what way, at what time, and with which students. The course is comprised of eight 2-hour sessions,…

  3. Rise of the micromachines: microfluidics and the future of cytometry.

    PubMed

    Wlodkowic, Donald; Darzynkiewicz, Zbigniew

    2011-01-01

    The past decade has brought many innovations to the field of flow and image-based cytometry. These advancements can be seen in the current miniaturization trends and simplification of analytical components found in the conventional flow cytometers. On the other hand, the maturation of multispectral imaging cytometry in flow imaging and the slide-based laser scanning cytometers offers great hopes for improved data quality and throughput while proving new vistas for the multiparameter, real-time analysis of cells and tissues. Importantly, however, cytometry remains a viable and very dynamic field of modern engineering. Technological milestones and innovations made over the last couple of years are bringing the next generation of cytometers out of centralized core facilities while making it much more affordable and user friendly. In this context, the development of microfluidic, lab-on-a-chip (LOC) technologies is one of the most innovative and cost-effective approaches toward the advancement of cytometry. LOC devices promise new functionalities that can overcome current limitations while at the same time promise greatly reduced costs, increased sensitivity, and ultra high throughputs. We can expect that the current pace in the development of novel microfabricated cytometric systems will open up groundbreaking vistas for the field of cytometry, lead to the renaissance of cytometric techniques and most importantly greatly support the wider availability of these enabling bioanalytical technologies. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Rise of the Micromachines: Microfluidics and the Future of Cytometry

    PubMed Central

    Wlodkowic, Donald; Darzynkiewicz, Zbigniew

    2011-01-01

    The past decade has brought many innovations to the field of flow and image-based cytometry. These advancements can be seen in the current miniaturization trends and simplification of analytical components found in the conventional flow cytometers. On the other hand, the maturation of multispectral imaging cytometry in flow imaging and the slide-based laser scanning cytometers offers great hopes for improved data quality and throughput while proving new vistas for the multiparameter, real-time analysis of cells and tissues. Importantly, however, cytometry remains a viable and very dynamic field of modern engineering. Technological milestones and innovations made over the last couple of years are bringing the next generation of cytometers out of centralized core facilities while making it much more affordable and user friendly. In this context, the development of microfluidic, lab-on-a-chip (LOC) technologies is one of the most innovative and cost-effective approaches toward the advancement of cytometry. LOC devices promise new functionalities that can overcome current limitations while at the same time promise greatly reduced costs, increased sensitivity, and ultra high throughputs. We can expect that the current pace in the development of novel microfabricated cytometric systems will open up groundbreaking vistas for the field of cytometry, lead to the renaissance of cytometric techniques and most importantly greatly support the wider availability of these enabling bioanalytical technologies. PMID:21704837

  5. Method for a quantitative investigation of the frozen flow hypothesis

    PubMed

    Schock; Spillar

    2000-09-01

    We present a technique to test the frozen flow hypothesis quantitatively, using data from wave-front sensors such as those found in adaptive optics systems. Detailed treatments of the theoretical background of the method and of the error analysis are presented. Analyzing data from the 1.5-m and 3.5-m telescopes at the Starfire Optical Range, we find that the frozen flow hypothesis is an accurate description of the temporal development of atmospheric turbulence on time scales of the order of 1-10 ms but that significant deviations from the frozen flow behavior are present for longer time scales.

  6. Beam-modulation methods in quantitative and flow visualization holographic interferometry

    NASA Technical Reports Server (NTRS)

    Decker, A.

    1986-01-01

    This report discusses heterodyne holographic interferometry and time-average holography with a frequency shifted reference beam. Both methods will be used for the measurement and visualization of internal transonic flows, where the target facility is a flutter cascade. The background and experimental requirements for both methods are reviewed. Measurements using heterodyne holographic interferometry are presented. The performance of the laser required for time-average holography of time-varying transonic flows is discussed.

  7. Vinpocetine Attenuates Neointimal Hyperplasia in Diabetic Rat Carotid Arteries after Balloon Injury

    PubMed Central

    Peng, Wenhui; Li, Hailing; Zhuang, Jianhui; Lu, Yuyan; Liu, Baoxin; Li, Xiankai; Li, Weiming; Xu, Yawei

    2014-01-01

    Background Diabetes exacerbates abnormal vascular smooth muscle cell (VSMC) accumulation in response to arterial wall injury. Vinpocetine has been shown to improve vascular remolding; however, little is known about the direct effects of vinpocetine on vascular complications mediated by diabetes. The objective of this study was to determine the effects of vinpocetine on hyperglycemia-facilitated neointimal hyperplasia and explore its possible mechanism. Materials and Methods Nondiabetic and diabetic rats were subjected to balloon injury of the carotid artery followed by 3-week treatment with either vinpocetine (10 mg/kg/day) or saline. Morphological analysis and proliferating cell nuclear antigen (PCNA) immunostaining were performed on day 21. Rat VSMCs proliferation was determined with 5-ethynyl-20-deoxyuridine cell proliferation assays. Chemokinesis was monitored with scratch assays, and production of reactive oxygen species (ROS) was assessed using a 2′,7′-dichlorodihydrofluorescein diacetate (H2DCFDA) flow cytometric assay. Apoptosis was detected by annexin V-FITC/PI flow cytometric assay. Cell signaling was assessed by immunblotting. Results Vinpocetine prevented intimal hyperplasia in carotid arteries in both normal (I/M ratio: 93.83 ± 26.45% versus 143.2 ± 38.18%, P<0.05) and diabetic animals (I/M ratio: 120.5 ± 42.55% versus 233.46 ± 33.98%, P<0.05) when compared to saline. The in vitro study demonstrated that vinpocetine significantly inhibited VSMCs proliferation and chemokinesis as well as ROS generation and apoptotic resistance, which was induced by high glucose (HG) treatment. Vinpocetine significantly abolished HG-induced phosphorylation of Akt and JNK1/2 without affecting their total levels. For downstream targets, HG-induced phosphorylation of IκBα was significantly inhibited by vinpocetine. Vinpocetine also attenuated HG-enhanced expression of PCNA, cyclin D1 and Bcl-2. Conclusions Vinpocetine attenuated neointimal formation in diabetic

  8. Online recognition of the multiphase flow regime and study of slug flow in pipeline

    NASA Astrophysics Data System (ADS)

    Liejin, Guo; Bofeng, Bai; Liang, Zhao; Xin, Wang; Hanyang, Gu

    2009-02-01

    Multiphase flow is the phenomenon existing widely in nature, daily life, as well as petroleum and chemical engineering industrial fields. The interface structure among multiphase and their movement are complicated, which distribute random and heterogeneously in the spatial and temporal scales and have multivalue of the flow structure and state[1]. Flow regime is defined as the macro feature about the multiphase interface structure and its distribution, which is an important feature to describe multiphase flow. The energy and mass transport mechanism differ much for each flow regimes. It is necessary to solve the flow regime recognition to get a clear understanding of the physical phenomena and their mechanism of multiphase flow. And the flow regime is one of the main factors affecting the online measurement accuracy of phase fraction, flow rate and other phase parameters. Therefore, it is of great scientific and technological importance to develop new principles and methods of multiphase flow regime online recognition, and of great industrial background. In this paper, the key reasons that the present method cannot be used to solve the industrial multiphase flow pattern recognition are clarified firstly. Then the prerequisite to realize the online recognition of multiphase flow regime is analyzed, and the recognition rules for partial flow pattern are obtained based on the massive experimental data. The standard templates for every flow regime feature are calculated with self-organization cluster algorithm. The multi-sensor data fusion method is proposed to realize the online recognition of multiphase flow regime with the pressure and differential pressure signals, which overcomes the severe influence of fluid flow velocity and the oil fraction on the recognition. The online recognition method is tested in the practice, which has less than 10 percent measurement error. The method takes advantages of high confidence, good fault tolerance and less requirement of

  9. Acoustic tests of a 15.2 centimeter-diameter potential flow convergent nozzle

    NASA Technical Reports Server (NTRS)

    Karchmer, A. M.; Dorsch, R. G.; Friedman, R.

    1974-01-01

    An experimental investigation of the jet noise radiated to the far field from a 15.2-cm-diam potential flow convergent nozzle has been conducted. Tests were made with unheated airflow over a range of subsonic nozzle exhaust velocities from 62 to 310m/sec. Mean and turbulent velocity measurements in the flow field of the nozzle exhaust indicated no apparent flow anomalies. Acoustic measurements yielded data uncontaminated by internal and/or background noise to velocities as low as 152m/sec. Finally, no significantly different acoustic characteristics between the potential flow nozzle and simple convergent nozzles were found.

  10. Flow cytometric minimal residual disease assessment of peripheral blood in acute lymphoblastic leukaemia patients has potential for early detection of relapsed extramedullary disease.

    PubMed

    Keegan, Alissa; Charest, Karry; Schmidt, Ryan; Briggs, Debra; Deangelo, Daniel J; Li, Betty; Morgan, Elizabeth A; Pozdnyakova, Olga

    2018-03-27

    To evaluate peripheral blood (PB) for minimal residual disease (MRD) assessment in adults with acute lymphoblastic leukaemia (ALL). We analysed 76 matched bone marrow (BM) aspirate and PB specimens independently for the presence of ALL MRD by six-colour flow cytometry (FC). The overall rate of BM MRD-positivity was 24% (18/76) and PB was also MRD-positive in 22% (4/18) of BM-positive cases. We identified two cases with evidence of leukaemic cells in PB at the time of the extramedullary relapse that were interpreted as MRD-negative in BM. The use of PB MRD as a non-invasive method for monitoring of systemic relapse may have added clinical and diagnostic value in patients with high risk of extramedullary disease. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Flow-cytometric identification of vinegars using a multi-parameter analysis optical detection module

    NASA Astrophysics Data System (ADS)

    Verschooten, T.; Ottevaere, H.; Vervaeke, M.; Van Erps, J.; Callewaert, M.; De Malsche, W.; Thienpont, H.

    2015-09-01

    We show a proof-of-concept demonstration of a multi-parameter analysis low-cost optical detection system for the flowcytometric identification of vinegars. This multi-parameter analysis system can simultaneously measure laser induced fluorescence, absorption and scattering excited by two time-multiplexed lasers of different wavelengths. To our knowledge no other polymer optofluidic chip based system offers more simultaneous measurements. The design of the optofluidic channels is aimed at countering the effects that viscous fingering, air bubbles, and emulsion samples can have on the correct operation of such a detection system. Unpredictable variations in viscosity and refractive index of the channel content can be turned into a source of information. The sample is excited by two laser diodes that are driven by custom made low-cost laser drivers. The optofluidic chip is built to be robust and easy to handle and is reproducible using hot embossing. We show a custom optomechanical holder for the optofluidic chip that ensures correct alignment and automatic connection to the external fluidic system. We show an experiment in which 92 samples of vinegar are measured. We are able to identify 9 different kinds of vinegar with an accuracy of 94%. Thus we show an alternative approach to the classic optical spectroscopy solution at a lowered. Furthermore, we have shown the possibility of predicting the viscosity and turbidity of vinegars with a goodness-of-fit R2 over 0.947.

  12. Field fertility of liquid stored and cryopreserved flow cytometrically sex-sorted stallion sperm.

    PubMed

    Gibb, Z; Grupen, C G; Maxwell, W M C; Morris, L H A

    2017-03-01

    The fertility of sex-sorted, cryopreserved stallion sperm must be improved for the sex-sorting technology to be applied commercially. To optimise the conditions used to liquid store stallion sperm prior to sex-sorting and assess the fertility of sperm following sex-sorting and cryopreservation. Both in vitro experiment and randomised controlled trial in healthy, client-owned mares. Stallion ejaculates (n = 9) were diluted in either a skimmed milk (KMT) or BSA (I-BSA) based media to 25 × 10 6 sperm/ml directly (+SP25) or washed to remove seminal plasma and diluted to 25 or 111 × 10 6 sperm/ml (-SP25 and -SP111). Sperm were stored for 18 h at 10 to 15°C and -SP25 and +SP25 treatments were centrifuged and resuspended to 111 × 10 6 sperm/ml. Sperm were incubated under H33342 staining conditions and motility, viability and acrosome integrity assessed. Semen was collected from stallions (n = 4), liquid stored at 10-15°C for up to 5 h and sperm either cryopreserved directly, sex-sorted and cryopreserved, or sex-sorted and returned to liquid storage until insemination. Low-dose hysteroscopic insemination was performed in 23 mares randomly allocated to the semen preparation group and pregnancy determined following embryo flushing on Day 9 after ovulation, or via transrectal ultrasonography on Day 14 after ovulation. Skimmed milk was superior to I-BSA in maintaining motility, viability and acrosome integrity. Seminal plasma removal did not affect the parameters measured at the concentrations examined. Conception rates did not differ significantly between the groups, although a high incidence of pregnancy loss was observed in both the cryopreserved groups. While the conception rates achieved are among the highest yet reported for sex-sorted, cryopreserved stallion sperm, the high incidence of pregnancy loss suggests that the development of the resulting embryos was significantly impaired by the sperm processing treatments. © 2016 EVJ Ltd.

  13. A Background Noise Reduction Technique Using Adaptive Noise Cancellation for Microphone Arrays

    NASA Technical Reports Server (NTRS)

    Spalt, Taylor B.; Fuller, Christopher R.; Brooks, Thomas F.; Humphreys, William M., Jr.; Brooks, Thomas F.

    2011-01-01

    Background noise in wind tunnel environments poses a challenge to acoustic measurements due to possible low or negative Signal to Noise Ratios (SNRs) present in the testing environment. This paper overviews the application of time domain Adaptive Noise Cancellation (ANC) to microphone array signals with an intended application of background noise reduction in wind tunnels. An experiment was conducted to simulate background noise from a wind tunnel circuit measured by an out-of-flow microphone array in the tunnel test section. A reference microphone was used to acquire a background noise signal which interfered with the desired primary noise source signal at the array. The technique s efficacy was investigated using frequency spectra from the array microphones, array beamforming of the point source region, and subsequent deconvolution using the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm. Comparisons were made with the conventional techniques for improving SNR of spectral and Cross-Spectral Matrix subtraction. The method was seen to recover the primary signal level in SNRs as low as -29 dB and outperform the conventional methods. A second processing approach using the center array microphone as the noise reference was investigated for more general applicability of the ANC technique. It outperformed the conventional methods at the -29 dB SNR but yielded less accurate results when coherence over the array dropped. This approach could possibly improve conventional testing methodology but must be investigated further under more realistic testing conditions.

  14. Morphologic, cytometric and functional characterization of the common octopus (Octopus vulgaris) hemocytes.

    PubMed

    Castellanos-Martínez, S; Prado-Alvarez, M; Lobo-da-Cunha, A; Azevedo, C; Gestal, C

    2014-05-01

    The hemocytes of Octopus vulgaris were morphologically and functionally characterized. Light and electron microscopy (TEM and SEM), and flow cytometry analyses revealed the existence of two hemocyte populations. Large granulocytes showed U-shaped nucleus, a mean of 11.6 μm±1.2 in diameter with basophilic granules, polysaccharide and lysosomic deposits in the cytoplasm. Small granulocytes measured a mean of 8.1 μm±0.7 in diameter, and have a round nucleus occupying almost the entire cell and few or not granules in the cytoplasm. Flow cytometry analysis showed that large granulocytes are the principal cells that develop phagocytosis of latex beads (rising up to 56%) and ROS after zymosan stimulation. Zymosan induced the highest production of both ROS and NO. This study is the first tread towards understanding the O. vulgaris immune system by applying new tools to provide a most comprehensive morpho-functional study of their hemocytes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Heat flow and hydrocarbon generation in the Transylvanian basin, Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cranganu, C.; Deming, D.

    1996-10-01

    The Transylvanian basin in central Romania is a Neogene depression superimposed on the Cretaceous nappe system of the Carpathian Mountains. The basin contains the main gas reserves of Romania, and is one of the most important gas-producing areas of continental Europe; since 1902, gas has been produced from more than 60 fields. Surface heat flow in the Transylvanian basin as estimated in other studies ranges from 26 to 58 mW/m{sup 2}, with a mean value of 38 mW/m{sup 2}, relatively low compared to surrounding areas. The effect of sedimentation on heat flow and temperature in the Transylvanian basin was estimatedmore » with a numerical model that solved the heat equation in one dimension. Because both sediment thickness and heat flow vary widely throughout the Transylvanian basin, a wide range of model variables were used to bracket the range of possibilities. Three different burial histories were considered (thin, average, and thick), along with three different values of background heat flow (low, average, and high). Altogether, nine different model permutations were studied. Modeling results show that average heat flow in the Transylvanian basin was depressed approximately 16% during rapid Miocene sedimentation, whereas present-day heat flow remains depressed, on average, about 17% below equilibrium values. We estimated source rock maturation and the timing of hydrocarbon generation by applying Lopatin`s method. Potential source rocks in the Transylvanian basin are Oligocene-Miocene, Cretaceous, and Jurassic black shales. Results show that potential source rocks entered the oil window no earlier than approximately 13 Ma, at depths of between 4200 and 8800 m. Most simulations encompassing a realistic range of sediment thicknesses and background heat flows show that potential source rocks presently are in the oil window; however, no oil has ever been discovered or produced in the Transylvanian basin.« less

  16. Development of Background-Oriented Schlieren for NASA Langley Research Center Ground Test Facilities

    NASA Technical Reports Server (NTRS)

    Bathel, Brett F.; Borg, Stephen; Jones, Stephen; Overmeyer, Austin; Walker, Eric; Goad, William; Clem, Michelle; Schairer, Edward T.; Mizukaki, Toshiharu

    2015-01-01

    This paper provides an overview of recent wind tunnel tests performed at the NASA Langley Research Center where the Background-Oriented Schlieren (BOS) technique was used to provide information pertaining to flow-field density disturbances. The facilities in which the BOS technique was applied included the National Transonic Facility (NTF), Transonic Dynamics Tunnel (TDT), 31-Inch Mach 10 Air Tunnel, 15-Inch Mach 6 High-Temperature Air Tunnel, Rotor Test Cell at the 14 by 22 Subsonic Tunnel, and a 13-Inch Low-Speed Tunnel.

  17. Visual signal detection in structured backgrounds. II. Effects of contrast gain control, background variations, and white noise

    NASA Technical Reports Server (NTRS)

    Eckstein, M. P.; Ahumada, A. J. Jr; Watson, A. B.

    1997-01-01

    Studies of visual detection of a signal superimposed on one of two identical backgrounds show performance degradation when the background has high contrast and is similar in spatial frequency and/or orientation to the signal. To account for this finding, models include a contrast gain control mechanism that pools activity across spatial frequency, orientation and space to inhibit (divisively) the response of the receptor sensitive to the signal. In tasks in which the observer has to detect a known signal added to one of M different backgrounds grounds due to added visual noise, the main sources of degradation are the stochastic noise in the image and the suboptimal visual processing. We investigate how these two sources of degradation (contrast gain control and variations in the background) interact in a task in which the signal is embedded in one of M locations in a complex spatially varying background (structured background). We use backgrounds extracted from patient digital medical images. To isolate effects of the fixed deterministic background (the contrast gain control) from the effects of the background variations, we conduct detection experiments with three different background conditions: (1) uniform background, (2) a repeated sample of structured background, and (3) different samples of structured background. Results show that human visual detection degrades from the uniform background condition to the repeated background condition and degrades even further in the different backgrounds condition. These results suggest that both the contrast gain control mechanism and the background random variations degrade human performance in detection of a signal in a complex, spatially varying background. A filter model and added white noise are used to generate estimates of sampling efficiencies, an equivalent internal noise, an equivalent contrast-gain-control-induced noise, and an equivalent noise due to the variations in the structured background.

  18. Mimicking Natural Laminar to Turbulent Flow Transition: A Systematic CFD Study Using PAB3D

    NASA Technical Reports Server (NTRS)

    Pao, S. Paul; Abdol-Hamid, Khaled S.

    2005-01-01

    For applied aerodynamic computations using a general purpose Navier-Stokes code, the common practice of treating laminar to turbulent flow transition over a non-slip surface is somewhat arbitrary by either treating the entire flow as turbulent or forcing the flow to undergo transition at given trip locations in the computational domain. In this study, the possibility of using the PAB3D code, standard k-epsilon turbulence model, and the Girimaji explicit algebraic stresses model to mimic natural laminar to turbulent flow transition was explored. The sensitivity of flow transition with respect to two limiters in the standard k-epsilon turbulence model was examined using a flat plate and a 6:1 aspect ratio prolate spheroid for our computations. For the flat plate, a systematic dependence of transition Reynolds number on background turbulence intensity was found. For the prolate spheroid, the transition patterns in the three-dimensional boundary layer at different flow conditions were sensitive to the free stream turbulence viscosity limit, the reference Reynolds number and the angle of attack, but not to background turbulence intensity below a certain threshold value. The computed results showed encouraging agreements with the experimental measurements at the corresponding geometry and flow conditions.

  19. A high-throughput direct fluorescence resonance energy transfer-based assay for analyzing apoptotic proteases using flow cytometry and fluorescence lifetime measurements.

    PubMed

    Suzuki, Miho; Sakata, Ichiro; Sakai, Takafumi; Tomioka, Hiroaki; Nishigaki, Koichi; Tramier, Marc; Coppey-Moisan, Maïté

    2015-12-15

    Cytometry is a versatile and powerful method applicable to different fields, particularly pharmacology and biomedical studies. Based on the data obtained, cytometric studies are classified into high-throughput (HTP) or high-content screening (HCS) groups. However, assays combining the advantages of both are required to facilitate research. In this study, we developed a high-throughput system to profile cellular populations in terms of time- or dose-dependent responses to apoptotic stimulations because apoptotic inducers are potent anticancer drugs. We previously established assay systems involving protease to monitor live cells for apoptosis using tunable fluorescence resonance energy transfer (FRET)-based bioprobes. These assays can be used for microscopic analyses or fluorescence-activated cell sorting. In this study, we developed FRET-based bioprobes to detect the activity of the apoptotic markers caspase-3 and caspase-9 via changes in bioprobe fluorescence lifetimes using a flow cytometer for direct estimation of FRET efficiencies. Different patterns of changes in the fluorescence lifetimes of these markers during apoptosis were observed, indicating a relationship between discrete steps in the apoptosis process. The findings demonstrate the feasibility of evaluating collective cellular dynamics during apoptosis. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. A complementary role of multiparameter flow cytometry and high-throughput sequencing for minimal residual disease detection in chronic lymphocytic leukemia: an European Research Initiative on CLL study.

    PubMed

    Rawstron, A C; Fazi, C; Agathangelidis, A; Villamor, N; Letestu, R; Nomdedeu, J; Palacio, C; Stehlikova, O; Kreuzer, K-A; Liptrot, S; O'Brien, D; de Tute, R M; Marinov, I; Hauwel, M; Spacek, M; Dobber, J; Kater, A P; Gambell, P; Soosapilla, A; Lozanski, G; Brachtl, G; Lin, K; Boysen, J; Hanson, C; Jorgensen, J L; Stetler-Stevenson, M; Yuan, C; Broome, H E; Rassenti, L; Craig, F; Delgado, J; Moreno, C; Bosch, F; Egle, A; Doubek, M; Pospisilova, S; Mulligan, S; Westerman, D; Sanders, C M; Emerson, R; Robins, H S; Kirsch, I; Shanafelt, T; Pettitt, A; Kipps, T J; Wierda, W G; Cymbalista, F; Hallek, M; Hillmen, P; Montserrat, E; Ghia, P

    2016-04-01

    In chronic lymphocytic leukemia (CLL) the level of minimal residual disease (MRD) after therapy is an independent predictor of outcome. Given the increasing number of new agents being explored for CLL therapy, using MRD as a surrogate could greatly reduce the time necessary to assess their efficacy. In this European Research Initiative on CLL (ERIC) project we have identified and validated a flow-cytometric approach to reliably quantitate CLL cells to the level of 0.0010% (10(-5)). The assay comprises a core panel of six markers (i.e. CD19, CD20, CD5, CD43, CD79b and CD81) with a component specification independent of instrument and reagents, which can be locally re-validated using normal peripheral blood. This method is directly comparable to previous ERIC-designed assays and also provides a backbone for investigation of new markers. A parallel analysis of high-throughput sequencing using the ClonoSEQ assay showed good concordance with flow cytometry results at the 0.010% (10(-4)) level, the MRD threshold defined in the 2008 International Workshop on CLL guidelines, but it also provides good linearity to a detection limit of 1 in a million (10(-6)). The combination of both technologies would permit a highly sensitive approach to MRD detection while providing a reproducible and broadly accessible method to quantify residual disease and optimize treatment in CLL.

  1. Design of Capillary Flows with Spatially Graded Porous Films

    NASA Astrophysics Data System (ADS)

    Joung, Young Soo; Figliuzzi, Bruno Michel; Buie, Cullen

    2013-11-01

    We have developed a new capillary tube model, consisting of multi-layered capillary tubes oriented in the direction of flow, to predict capillary speeds on spatially graded porous films. Capillary flows through thin porous media have been widely utilized for small size liquid transport systems. However, for most media it is challenging to realize arbitrary shapes and spatially functionalized micro-structures with variable flow properties. Therefore, conventional media can only be used for capillary flows obeying Washburn's equation and the modifications thereof. Given this background, we recently developed a method called breakdown anodization (BDA) to produce highly wetting porous films. The resulting surfaces show nearly zero contact angles and fast water spreading speed. Furthermore, capillary pressure and spreading diffusivity can be expressed as functions of capillary height when customized electric fields are used in BDA. From the capillary tube model, we derived a general capillary flow equation of motion in terms of capillary pressure and spreading diffusivity. The theoretical model shows good agreement with experimental capillary flows. The study will provide novel design methodologies for paper-based microfluidic devices.

  2. A noninvasive method for measuring the velocity of diffuse hydrothermal flow by tracking moving refractive index anomalies

    NASA Astrophysics Data System (ADS)

    Mittelstaedt, Eric; Davaille, Anne; van Keken, Peter E.; Gracias, Nuno; Escartin, Javier

    2010-10-01

    Diffuse flow velocimetry (DFV) is introduced as a new, noninvasive, optical technique for measuring the velocity of diffuse hydrothermal flow. The technique uses images of a motionless, random medium (e.g., rocks) obtained through the lens of a moving refraction index anomaly (e.g., a hot upwelling). The method works in two stages. First, the changes in apparent background deformation are calculated using particle image velocimetry (PIV). The deformation vectors are determined by a cross correlation of pixel intensities across consecutive images. Second, the 2-D velocity field is calculated by cross correlating the deformation vectors between consecutive PIV calculations. The accuracy of the method is tested with laboratory and numerical experiments of a laminar, axisymmetric plume in fluids with both constant and temperature-dependent viscosity. Results show that average RMS errors are ˜5%-7% and are most accurate in regions of pervasive apparent background deformation which is commonly encountered in regions of diffuse hydrothermal flow. The method is applied to a 25 s video sequence of diffuse flow from a small fracture captured during the Bathyluck'09 cruise to the Lucky Strike hydrothermal field (September 2009). The velocities of the ˜10°C-15°C effluent reach ˜5.5 cm/s, in strong agreement with previous measurements of diffuse flow. DFV is found to be most accurate for approximately 2-D flows where background objects have a small spatial scale, such as sand or gravel.

  3. Illuminating the Background: Topics in Cosmic Microwave Background Polarization Research

    NASA Astrophysics Data System (ADS)

    Miller, Nathan J.

    The cosmic microwave background provides a wealth of information about the origin and history of the universe. The statistics of the anisotropy and the polarization of the cosmic microwave background, among other things, can tell us about the distribution of matter, the redshift of reionization, and the nature of the primordial uctuations. From the lensing of cosmic microwave background due to intervening matter, we can extract information about neutrinos and the equation of state of dark energy. A measurement of the large angular scale B-mode polarization has been called the "smoking gun" of in ation, a theory that describes a possible early rapid expansion of the universe. The focus of current experiments is to measure this B-mode polarization, while several experiments, such as POLARBEAR, are also looking to measure the lensing of the cosmic microwave background. This dissertation will discuss several different topics in cosmic microwave background polarization research. I will make predictions for future experiments and I will also show analysis for two current experiments, POLARBEAR and BICEP. I will show how beam systematics affect the measurement of cosmological parameters and how well we must limit these systematics in order to get unbiased constraints on cosmological parameters for future experiments. I will discuss a novel way of using the temperature-polarization cross correlation to constrain the amount of inflationary gravitational waves. Through Markov Chain Monte Carlo methods, I will determine how well future experiments will be able to constrain the neutrino masses and their degeneracy parameters. I will show results from current data analysis and calibration being done on the Cedar Flat deployment for the POLARBEAR experiment which is currently being constructed in the Atacama desert in Chile. Finally, I will analyze the claim of detection of cosmological birefringence in the BICEP data and show that there is reason to believe it is due to

  4. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing

    PubMed Central

    2015-01-01

    Background The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Methods Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. Results The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. Conclusion The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates. PMID:26192188

  5. United States, 2002 : 2002 Economic Census : Transportation : 2002 commodity flow survey

    DOT National Transportation Integrated Search

    2004-12-01

    This report contains background information on the 2002 Commodity Flow Survey and then presents : detailed tabular results on shipment characteristics by mode of transportation, commodity, : distance shipped, and shipment weight. In Appendix A, key c...

  6. Passive swimming in viscous oscillatory flows

    NASA Astrophysics Data System (ADS)

    Jo, Ikhee; Huang, Yangyang; Zimmermann, Walter; Kanso, Eva

    2016-12-01

    Fluid-based locomotion at low Reynolds number is subject to the constraints of Purcell's scallop theorem: reciprocal shape kinematics identical under a time-reversal symmetry cannot cause locomotion. In particular, a single degree-of-freedom scallop undergoing opening and closing motions cannot swim. Most strategies for symmetry breaking and locomotion rely on direct control of the swimmer's shape kinematics. Less is known about indirect control via actuation of the fluid medium. To address how such indirect actuation strategies can lead to locomotion, we analyze a Λ -shaped model system analogous to Purcell's scallop but able to deform passively in oscillatory flows. Neutrally buoyant scallops undergo no net locomotion. We show that dense, elastic scallops can exhibit passive locomotion in zero-mean oscillatory flows. We examine the efficiency of swimming parallel to the background flow and analyze the stability of these motions. We observe transitions from stable to unstable swimming, including ordered transitions from fluttering to chaoticlike motions and tumbling. Our results demonstrate that flow oscillations can be used to passively actuate and control the motion of microswimmers, which may be relevant to applications such as surgical robots and cell sorting and manipulation in microfluidic devices.

  7. Background Underground at WIPP

    NASA Astrophysics Data System (ADS)

    Esch, Ernst-Ingo; Hime, A.; Bowles, T. J.

    2001-04-01

    Recent interest to establish a dedicated underground laboratory in the United States prompted an experimental program at to quantify the enviromental backgrounds underground at the Waste Isolation Pilot Plant (WIPP) in Carlsbad, New Mexico. An outline of this program is provided along with recent experimental data on the cosmic ray muon flux at the 650 meter level of WIPP. The implications of the cosmic ray muon and fast neutron background at WIPP will be discussed in the context of new generation, low background experiments envisioned in the future.

  8. Detailed immunophenotyping of B-cell precursors in regenerating bone marrow of acute lymphoblastic leukaemia patients: implications for minimal residual disease detection.

    PubMed

    Theunissen, Prisca M J; Sedek, Lukasz; De Haas, Valerie; Szczepanski, Tomasz; Van Der Sluijs, Alita; Mejstrikova, Ester; Nováková, Michaela; Kalina, Tomas; Lecrevisse, Quentin; Orfao, Alberto; Lankester, Arjan C; van Dongen, Jacques J M; Van Der Velden, Vincent H J

    2017-07-01

    Flow cytometric detection of minimal residual disease (MRD) in children with B-cell precursor acute lymphoblastic leukaemia (BCP-ALL) requires immunophenotypic discrimination between residual leukaemic cells and B-cell precursors (BCPs) which regenerate during therapy intervals. In this study, EuroFlow-based 8-colour flow cytometry and innovative analysis tools were used to first characterize the immunophenotypic maturation of normal BCPs in bone marrow (BM) from healthy children, resulting in a continuous multiparametric pathway including transition stages. This pathway was subsequently used as a reference to characterize the immunophenotypic maturation of regenerating BCPs in BM from children treated for BCP-ALL. We identified pre-B-I cells that expressed low or dim CD34 levels, in contrast to the classical CD34 high pre-B-I cell immunophenotype. These CD34 -dim pre-B-I cells were relatively abundant in regenerating BM (11-85% within pre-B-I subset), while hardly present in healthy control BM (9-13% within pre-B-I subset; P = 0·0037). Furthermore, we showed that some of the BCP-ALL diagnosis immunophenotypes (23%) overlapped with CD34 -dim pre-B-I cells. Our results indicate that newly identified CD34 -dim pre-B-I cells can be mistaken for residual BCP-ALL cells, potentially resulting in false-positive MRD outcomes. Therefore, regenerating BM, in which CD34 -dim pre-B-I cells are relatively abundant, should be used as reference frame in flow cytometric MRD measurements. © 2017 John Wiley & Sons Ltd.

  9. Evaluation of Premarin in a Rat Model of Mild and Severe Hemorrhage

    DTIC Science & Technology

    2013-10-04

    extracellular-only ligand ) on peripheral blood lymphocytes, as revealed in flow cytometric analysis. In Figure 20 (previous page) it is clear that in...magenta) which dropped to 27% with STSi pretreatment in vivo. This precluded accurate evaluation of EE-3-SO4 as ligand for ER in the context of...unable to enter the cell and engage the intracellular estrogen receptor GPER , where synthetic cell permeable (i.e., hydrophobic constructs) freely

  10. Mitigation of Debris Flow Damage--­ A Case Study of Debris Flow Damage

    NASA Astrophysics Data System (ADS)

    Lin, J. C.; Jen, C. H.

    Typhoon Toraji caused more than 30 casualties in Central Taiwan on the 31st July 2001. It was the biggest Typhoon since the Chi-Chi earthquake of 1999 with huge amounts of rainfall. Because of the influence of the earthquake, loose debris falls and flows became major hazards in Central Taiwan. Analysis of rainfall data and sites of slope failure show that damage from these natural hazards were enhanced as a result of the Chi-Chi earthquake. Three main types of hazard occurred in Central Taiwan: land- slides, debris flows and gully erosion. Landslides occurred mainly along hill slopes and banks of channels. Many dams and houses were destroyed by flooding. Debris flows occurred during typhoon periods and re-activated ancient debris depositions. Many new gullies were therefore developed from deposits loosened and shaken by the earthquake. This paper demonstrates the geological/geomorphological background of the hazard area, and reviews methods of damage mitigation in central Taiwan. A good example is Hsi-Tou, which had experienced no gully erosion for more than 40 years. The area experienced much gully erosion as a result of the combined effects of earth- quake and typhoon. Although Typhoon Toraji produced only 30% of the rainfall of Typhoon Herb of 1996, it caused more damage in the Hsi-Tou area. The mitigation of debris flow hazards in Hsi-tou area is discussed in this paper.

  11. Characterization of Mast Cell Activation Syndrome

    PubMed Central

    Afrin, Lawrence B.; Self, Sally; Menk, Jeremiah; Lazarchick, John

    2016-01-01

    Background Mast cell activation syndrome (MCAS), a recently recognized non-neoplastic mast cell (MC) disease driving chronic multisystem inflammation ± allergy, appears prevalent and thus important. We report the first systematic characterization of a large MCAS population. Method Demographics, comorbidities, symptoms, family histories, and physical exam and laboratory findings were reviewed in 298 retrospective and 115 prospective MCAS patients. Blood samples from prospective subjects were examined by flow cytometry for clonal MC disease and tested for cytokines potentially driving the monocytosis frequent in MCAS. Results Demographically, white females dominated. Median ages at symptom onset/diagnosis were 9/49 years (ranges 0–88/16–92); median time from symptom onset to diagnosis was 30 years (range 1–85). Median numbers of comorbidities/symptoms/family medical issues were 11/20/4 (ranges 1–66/2–84/0–33). Gastroesophageal reflux, fatigue, and dermatographism were the most common comorbidity, symptom, and exam finding. Abnormalities in routine labs were common and diverse but typically modest. The most useful diagnostic markers were heparin, prostaglandin D2, histamine, and chromogranin A. Flow cytometric and cytokine assessments were unhelpful. Conclusions Our study highlights MCAS’s morbidity burden and challenging heterogeneity. Recognition is important given good survival and treatment prospects. PMID:28262205

  12. Dilatonic parallelizable NS-NS backgrounds

    NASA Astrophysics Data System (ADS)

    Kawano, Teruhiko; Yamaguchi, Satoshi

    2003-08-01

    We complete the classification of parallelizable NS-NS backgrounds in type II supergravity by adding the dilatonic case to the result of Figueroa-O'Farrill on the non-dilatonic case. We also study the supersymmetry of these parallelizable backgrounds. It is shown that all the dilatonic parallelizable backgrounds have sixteen supersymmetries.

  13. Myasthenia gravis sera have no effect on cardiomyocytes in vitro.

    PubMed

    Helgeland, Geir; Luckman, Steven P; Romi, Fredrik R; Jonassen, Anne K; Gilhus, Nils Erik

    2008-09-15

    Myasthenia gravis (MG) is an autoimmune disorder primarily caused by circulating autoantibodies targeting the nicotinic acetylcholine receptor. Several studies have suggested a link between MG and heart disease. Girardi heart cells were treated with MG sera, measuring cytotoxic effects using flow cytometry, adenylate kinase (AK) release and evaluating morphology. MG sera did not induce morphological changes in the cells. AK release from cells treated with MG sera did not exceed controls and flow cytometric examination did not reveal any increase in dead or apoptotic cells. We conclude that MG sera have no cytotoxic effect in our heart cell culture system.

  14. Flow cytometric characterization of culture expanded multipotent mesenchymal stromal cells (MSCs) from horse adipose tissue: towards the definition of minimal stemness criteria.

    PubMed

    Pascucci, L; Curina, G; Mercati, F; Marini, C; Dall'Aglio, C; Paternesi, B; Ceccarelli, P

    2011-12-15

    In the last decades, multipotent mesenchymal progenitor cells have been isolated from many adult tissues of different species. The International Society for Cellular Therapy (ISCT) has recently established that multipotent mesenchymal stromal cells (MSCs) is the currently recommended designation. In this study, we used flow cytometry to evaluate the expression of several molecules related to stemness (CD90, CD44, CD73 and STRO-1) in undifferentiated, early-passaged MSCs isolated from adipose tissue of four donor horses (AdMSCs). The four populations unanimously expressed high levels of CD90 and CD44. On the contrary, they were unexpectedly negative to CD73. A small percentage of the cells, finally, showed the expression of STRO-1. This last result might be due to the existence of a small subpopulation of STRO-1+ cells or to a poor cross-reactivity of the antibody. A remarkable donor-to-donor consistency and reproducibility of these findings was demonstrated. The data presented herein support the idea that equine AdMSCs may be easily isolated and selected by adherence to tissue culture plastic and exhibit a surface profile characterized by some peculiar differences in comparison to those described in other species. Continued characterization of these cells will help to clarify several aspects of their biology and may ultimately enable the isolation of specific, purified subpopulations. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Food Utilization (Energy-Flow) Investigations with Pieris Brassicae (Large White) Caterpillars.

    ERIC Educational Resources Information Center

    Jones, Derek H. T.

    1985-01-01

    Background information, procedures used, and typical results obtained are provided for experiments in which caterpillars are used to investigate energy-flow relationships. Areas in which the experiments could be used include ecology, applied biology, and animal feeding. (DH)

  16. Total sleep deprivation decreases flow experience and mood status

    PubMed Central

    Kaida, Kosuke; Niki, Kazuhisa

    2014-01-01

    Background The purpose of this study was to examine the effect of sleep deprivation on flow experience. Methods Sixteen healthy male volunteers of mean age 21.4±1.59 (21–24) years participated in two experimental conditions, ie, sleep-deprivation and normal sleep. In the sleep-deprived condition, participants stayed awake at home for 36 hours (from 8 am until 10 pm the next day) beginning on the day prior to an experimental day. In both conditions, participants carried out a simple reaction time (psychomotor vigilance) task and responded to a questionnaire measuring flow experience and mood status. Results Flow experience was reduced after one night of total sleep deprivation. Sleep loss also decreased positive mood, increased negative mood, and decreased psychomotor performance. Conclusion Sleep deprivation has a strong impact on mental and behavioral states associated with the maintenance of flow, namely subjective well-being. PMID:24376356

  17. Two- and three-dimensional turbine blade row flow field simulations

    NASA Technical Reports Server (NTRS)

    Buggeln, R. C.; Briley, W. R.; Mcdonald, H.; Shamroth, S. J.; Weinberg, B. C.

    1987-01-01

    Work performed in the numerical simulation of turbine passage flows via a Navier-Stokes approach is discussed. Both laminar and turbulent simulations in both two and three dimensions are discussed. An outline of the approach, background, and an overview of the results are given.

  18. On the Rayleigh-Taylor Instability in Presence of a Background Shear

    NASA Astrophysics Data System (ADS)

    Shvydkoy, Roman

    2018-01-01

    In this note we revisit the classical subject of the Rayleigh-Taylor instability in presence of an incompressible background shear flow. We derive a formula for the essential spectral radius of the evolution group generated by the linearization near the steady state and reveal that the velocity variations neutralize shortwave instabilities. The formula is a direct generalization of the result of Hwang and Guo (Arch Ration Mech Anal 167(3):235-253, (2003). Furthermore, we construct a class of steady states which posses unstable discrete spectrum with neutral essential spectrum. The technique involves the WKB analysis of the evolution equation and contains novel compactness criterion for pseudo-differential operators on unbounded domains.

  19. Is the Heart a Pressure or Flow Generator? Possible Implications and Suggestions for Cardiovascular Pedagogy

    ERIC Educational Resources Information Center

    Mitchell, Jamie R.

    2015-01-01

    In this article, a physiology instructor with primarily a cardiovascular (CV) background has wondered what approach to take, with both novice and senior learners, when it comes to delivering material on the pressure or flow generation of the heart. A debate surrounds the pressure propulsion versus flow generation theories, where some understand…

  20. Flow sorting of C-genome chromosomes from wild relatives of wheat Aegilops markgrafii, Ae. triuncialis and Ae. cylindrica, and their molecular organization.

    PubMed

    Molnár, István; Vrána, Jan; Farkas, András; Kubaláková, Marie; Cseh, András; Molnár-Láng, Márta; Doležel, Jaroslav

    2015-08-01

    Aegilops markgrafii (CC) and its natural hybrids Ae. triuncialis (U(t)U(t)C(t)C(t)) and Ae. cylindrica (D(c)D(c)C(c)C(c)) represent a rich reservoir of useful genes for improvement of bread wheat (Triticum aestivum), but the limited information available on their genome structure and the shortage of molecular (cyto-) genetic tools hamper the utilization of the extant genetic diversity. This study provides the complete karyotypes in the three species obtained after fluorescent in situ hybridization (FISH) with repetitive DNA probes, and evaluates the potential of flow cytometric chromosome sorting. The flow karyotypes obtained after the analysis of 4',6-diamidino-2-phenylindole (DAPI)-stained chromosomes were characterized and the chromosome content of the peaks on the flow karyotypes was determined by FISH. Twenty-nine conserved orthologous set (COS) markers covering all seven wheat homoeologous chromosome groups were used for PCR with DNA amplified from flow-sorted chromosomes and genomic DNA. FISH with repetitive DNA probes revealed that chromosomes 4C, 5C, 7C(t), T6U(t)S.6U(t)L-5C(t)L, 1C(c) and 5D(c) could be sorted with purities ranging from 66 to 91 %, while the remaining chromosomes could be sorted in groups of 2-5. This identified a partial wheat-C-genome homology for group 4 and 5 chromosomes. In addition, 1C chromosomes were homologous with group 1 of wheat; a small segment from group 2 indicated 1C-2C rearrangement. An extensively rearranged structure of chromosome 7C relative to wheat was also detected. The possibility of purifying Aegilops chromosomes provides an attractive opportunity to investigate the structure and evolution of the Aegilops C genome and to develop molecular tools to facilitate the identification of alien chromatin and support alien introgression breeding in bread wheat. © The Author 2015. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.