NASA Astrophysics Data System (ADS)
Iyengar, A.; Beach, M.; Newby, R. J.; Fabris, L.; Heilbronn, L. H.; Hayward, J. P.
2015-02-01
Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee, USA. The 0.5 m2 system, consisting of eight EJ-301 liquid scintillation detectors, was used to collect neutron background measurements in order to better understand the systematic variations in background that depend solely on the street-level measurement position in a downtown area. Data was collected along 5 different streets, and the measurements were found to be repeatable. Using 10-min measurements, the fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10% to 50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the net shielding of the cosmic ray neutron flux by adjacent buildings. For reference, the building structure as observed at street level is quantified in part here by a measured angle-of-open-sky metric.
Radiated BPF sound measurement of centrifugal compressor
NASA Astrophysics Data System (ADS)
Ohuchida, S.; Tanaka, K.
2013-12-01
A technique to measure radiated BPF sound from an automotive turbocharger compressor impeller is proposed in this paper. Where there are high-level background noises in the measurement environment, it is difficult to discriminate the target component from the background. Since the effort of measuring BPF sound was taken in a room with such condition in this study, no discrete BPF peak was initially found on the sound spectrum. Taking its directionality into consideration, a microphone covered with a parabolic cone was selected and using this technique, the discrete peak of BPF was clearly observed. Since the level of measured sound was amplified due to the area-integration effect, correction was needed to obtain the real level. To do so, sound measurements with and without a parabolic cone were conducted for the fixed source and their level differences were used as correction factors. Consideration is given to the sound propagation mechanism utilizing measured BPF as well as the result of a simple model experiment. The present method is generally applicable to sound measurements conducted with a high level of background noise.
Judgments of aircraft noise in a traffic noise background
NASA Technical Reports Server (NTRS)
Powell, C. A.; Rice, C. G.
1975-01-01
An investigation was conducted to determine subjective response to aircraft noise in different road traffic backgrounds. In addition, two laboratory techniques for presenting the aircraft noise with the background noise were evaluated. For one technique, the background noise was continuous over an entire test session; for the other, the background noise level was changed with each aircraft noise during a session. Subjective response to aircraft noise was found to decrease with increasing background noise level, for a range of typical indoor noise levels. Subjective response was found to be highly correlated with the Noise Pollution Level (NPL) measurement scale.
Advanced Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing
NASA Technical Reports Server (NTRS)
Bahr, Christopher J.; Horne, William C.
2015-01-01
An advanced form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique, based on an eigenvalue decomposition of the background noise cross-spectral matrix, is robust against situations where isolated background auto-spectral levels are measured to be higher than levels of combined source and background signals. It also provides an alternate estimate of the cross-spectrum, which previously might have poor definition for low signal-to-noise ratio measurements. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels. Experimental results show limited success in recovering signal behavior for data where conventional background subtraction fails. They also demonstrate the new subtraction technique's ability to maintain a proper coherence relationship in the modified cross-spectral matrix. Beam-forming and de-convolution results indicate the method can successfully separate sources. Results also show a reduced need for the use of diagonal removal in phased array processing, at least for the limited data sets considered.
Scatolini, Fabio; Alves, Cláudio Jorge Pinto
2016-01-01
ABSTRACT OBJECTIVE To perform a quantitative analysis of the background noise at Congonhas Airport surroundings based on large sampling and measurements with no interruption. METHODS Measuring sites were chosen from 62 and 72 DNL (day-night-level) noise contours, in urban sites compatible with residential use. Fifteen sites were monitored for at least 168 hours without interruption or seven consecutive days. Data compilation was based on cross-reference between noise measurements and air traffic control records, and results were validated by airport meteorological reports. Preliminary diagnoses were established using the standard NBR-13368. Background noise values were calculated based on the Sound Exposure Level (SEL). Statistic parameters were calculated in one-hour intervals. RESULTS Only four of the fifteen sites assessed presented aircraft operations as a clear cause for the noise annoyance. Even so, it is possible to detect background noise levels above regulation limits during periods of low airport activity or when it closes at night. CONCLUSIONS All the sites monitored showed background noise levels above regulation limits between 7:00 and 21:00. In the intervals between 6:00-6:59 and 21:00-22:59 the noise data, when analyzed with the current airport operational characteristics, still allow the development of additional mitigating measures. PMID:28099658
Measurement of speech levels in the presence of time varying background noise
NASA Technical Reports Server (NTRS)
Pearsons, K. S.; Horonjeff, R.
1982-01-01
Short-term speech level measurements which could be used to note changes in vocal effort in a time varying noise environment were studied. Knowing the changes in speech level would in turn allow prediction of intelligibility in the presence of aircraft flyover noise. Tests indicated that it is possible to use two second samples of speech to estimate long term root mean square speech levels. Other tests were also performed in which people read out loud during aircraft flyover noise. Results of these tests indicate that people do indeed raise their voice during flyovers at a rate of about 3-1/2 dB for each 10 dB increase in background level. This finding is in agreement with other tests of speech levels in the presence of steady state background noise.
Noise levels in an urban Asian school environment
Chan, Karen M.K.; Li, Chi Mei; Ma, Estella P.M.; Yiu, Edwin M.L.; McPherson, Bradley
2015-01-01
Background noise is known to adversely affect speech perception and speech recognition. High levels of background noise in school classrooms may affect student learning, especially for those pupils who are learning in a second language. The current study aimed to determine the noise level and teacher speech-to-noise ratio (SNR) in Hong Kong classrooms. Noise level was measured in 146 occupied classrooms in 37 schools, including kindergartens, primary schools, secondary schools and special schools, in Hong Kong. The mean noise levels in occupied kindergarten, primary school, secondary school and special school classrooms all exceeded recommended maximum noise levels, and noise reduction measures were seldom used in classrooms. The measured SNRs were not optimal and could have adverse implications for student learning and teachers’ vocal health. Schools in urban Asian environments are advised to consider noise reduction measures in classrooms to better comply with recommended maximum noise levels for classrooms. PMID:25599758
Noise levels in an urban Asian school environment.
Chan, Karen M K; Li, Chi Mei; Ma, Estella P M; Yiu, Edwin M L; McPherson, Bradley
2015-01-01
Background noise is known to adversely affect speech perception and speech recognition. High levels of background noise in school classrooms may affect student learning, especially for those pupils who are learning in a second language. The current study aimed to determine the noise level and teacher speech-to-noise ratio (SNR) in Hong Kong classrooms. Noise level was measured in 146 occupied classrooms in 37 schools, including kindergartens, primary schools, secondary schools and special schools, in Hong Kong. The mean noise levels in occupied kindergarten, primary school, secondary school and special school classrooms all exceeded recommended maximum noise levels, and noise reduction measures were seldom used in classrooms. The measured SNRs were not optimal and could have adverse implications for student learning and teachers' vocal health. Schools in urban Asian environments are advised to consider noise reduction measures in classrooms to better comply with recommended maximum noise levels for classrooms.
Background radiation measurements at high power research reactors
NASA Astrophysics Data System (ADS)
Ashenfelter, J.; Balantekin, B.; Baldenegro, C. X.; Band, H. R.; Barclay, G.; Bass, C. D.; Berish, D.; Bowden, N. S.; Bryan, C. D.; Cherwinka, J. J.; Chu, R.; Classen, T.; Davee, D.; Dean, D.; Deichert, G.; Dolinski, M. J.; Dolph, J.; Dwyer, D. A.; Fan, S.; Gaison, J. K.; Galindo-Uribarri, A.; Gilje, K.; Glenn, A.; Green, M.; Han, K.; Hans, S.; Heeger, K. M.; Heffron, B.; Jaffe, D. E.; Kettell, S.; Langford, T. J.; Littlejohn, B. R.; Martinez, D.; McKeown, R. D.; Morrell, S.; Mueller, P. E.; Mumm, H. P.; Napolitano, J.; Norcini, D.; Pushin, D.; Romero, E.; Rosero, R.; Saldana, L.; Seilhan, B. S.; Sharma, R.; Stemen, N. T.; Surukuchi, P. T.; Thompson, S. J.; Varner, R. L.; Wang, W.; Watson, S. M.; White, B.; White, C.; Wilhelmi, J.; Williams, C.; Wise, T.; Yao, H.; Yeh, M.; Yen, Y.-R.; Zhang, C.; Zhang, X.; Prospect Collaboration
2016-01-01
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including γ-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.
Iyengar, Anagha; Beach, Matthew; Newby, Robert J.; ...
2015-11-12
Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reductionmore » in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.« less
Measurement and reduction of low-level radon background in the KATRIN experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fränkle, F. M.
The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next generation, model independent, large scale experiment to determine the mass of the electron anti-neutrino by investigating the kinematics of tritium beta decay with a sensitivity of 200 meV/c{sup 2}. The measurement setup consists of a high luminosity windowless gaseous molecular tritium source (WGTS), a differential and cryogenic pumped electron transport and tritium retention section, a tandem spectrometer section (pre-spectrometer and main spectrometer) for energy analysis, followed by a detector system for counting transmitted beta decay electrons. Measurements performed at the KATRIN pre-spectrometer test setup showed that the decay of radon (Rn)more » atoms in the volume of the KATRIN spectrometers is a major background source. Rn atoms from low-level radon emanation of materials inside the vacuum region of the KATRIN spectrometers are able to penetrate deep into the magnetic flux tube so that the alpha decay of Rn contributes to the background. Of particular importance are electrons emitted in processes accompanying the Rn alpha decay, such as shake-off, internal conversion of excited levels in the Rn daughter atoms and Auger electrons. Lowenergy electrons (< 100 eV) directly contribute to the background in the signal region. High-energy electrons can be stored magnetically inside the volume of the spectrometer and are able to create thousands of secondary electrons via subsequent ionization processes with residual gas molecules. In order to reduce the Rn induced background different active and passive counter measures were developed and tested. This proceeding will give an overview on Rn sources within the KATRIN spectrometer, describes how Rn decays inside the spectrometer produce background events at the detector and presents different counter measures to reduce the Rn induced background.« less
Measurement and reduction of low-level radon background in the KATRIN experiment
NASA Astrophysics Data System (ADS)
Fränkle, F. M.
2013-08-01
The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next generation, model independent, large scale experiment to determine the mass of the electron anti-neutrino by investigating the kinematics of tritium beta decay with a sensitivity of 200 meV/c2. The measurement setup consists of a high luminosity windowless gaseous molecular tritium source (WGTS), a differential and cryogenic pumped electron transport and tritium retention section, a tandem spectrometer section (pre-spectrometer and main spectrometer) for energy analysis, followed by a detector system for counting transmitted beta decay electrons. Measurements performed at the KATRIN pre-spectrometer test setup showed that the decay of radon (Rn) atoms in the volume of the KATRIN spectrometers is a major background source. Rn atoms from low-level radon emanation of materials inside the vacuum region of the KATRIN spectrometers are able to penetrate deep into the magnetic flux tube so that the alpha decay of Rn contributes to the background. Of particular importance are electrons emitted in processes accompanying the Rn alpha decay, such as shake-off, internal conversion of excited levels in the Rn daughter atoms and Auger electrons. Lowenergy electrons (< 100 eV) directly contribute to the background in the signal region. High-energy electrons can be stored magnetically inside the volume of the spectrometer and are able to create thousands of secondary electrons via subsequent ionization processes with residual gas molecules. In order to reduce the Rn induced background different active and passive counter measures were developed and tested. This proceeding will give an overview on Rn sources within the KATRIN spectrometer, describes how Rn decays inside the spectrometer produce background events at the detector and presents different counter measures to reduce the Rn induced background.
Nordøy, Erling S; Lager, Anne R; Schots, Pauke C
2017-12-01
The aim of this study was to monitor seasonal changes in stable isotopes of pool freshwater and harp seal ( Phoca groenlandica ) body water, and to study whether these potential seasonal changes might bias results obtained using the doubly labelled water (DLW) method when measuring energy expenditure in animals with access to freshwater. Seasonal changes in the background levels of deuterium and oxygen-18 in the body water of four captive harp seals and in the freshwater pool in which they were kept were measured over a time period of 1 year. The seals were offered daily amounts of capelin and kept under a seasonal photoperiod of 69°N. Large seasonal variations of deuterium and oxygen-18 in the pool water were measured, and the isotope abundance in the body water showed similar seasonal changes to the pool water. This shows that the seals were continuously equilibrating with the surrounding water as a result of significant daily water drinking. Variations in background levels of deuterium and oxygen-18 in freshwater sources may be due to seasonal changes in physical processes such as precipitation and evaporation that cause fractionation of isotopes. Rapid and abrupt changes in the background levels of deuterium and oxygen-18 may complicate calculation of energy expenditure by use of the DLW method. It is therefore strongly recommended that analysis of seasonal changes in background levels of isotopes is performed before the DLW method is applied on (free-ranging) animals, and to use a control group in order to correct for changes in background levels. © 2017. Published by The Company of Biologists Ltd.
NASA Technical Reports Server (NTRS)
Mason, B. S.; Pearson, T. J.; Readhead, A. C. S.; Shepherd, M. C.; Sievers, J.; Udomprasert, P. S.; Cartwright, J. K.; Farmer, A. J.; Padin, S.; Myers, S. T.;
2002-01-01
We report measurements of anisotropy in the cosmic microwave background radiation over the multipole range l approximately 200 (right arrow) 3500 with the Cosmic Background Imager based on deep observations of three fields. These results confirm the drop in power with increasing l first reported in earlier measurements with this instrument, and extend the observations of this decline in power out to l approximately 2000. The decline in power is consistent with the predicted damping of primary anisotropies. At larger multipoles, l = 2000-3500, the power is 3.1 sigma greater than standard models for intrinsic microwave background anisotropy in this multipole range, and 3.5 sigma greater than zero. This excess power is not consistent with expected levels of residual radio source contamination but, for sigma 8 is approximately greater than 1, is consistent with predicted levels due to a secondary Sunyaev-Zeldovich anisotropy. Further observations are necessary to confirm the level of this excess and, if confirmed, determine its origin.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iyengar, Anagha; Beach, Matthew; Newby, Robert J.
Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reductionmore » in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.« less
The Radio Synchrotron Background: Conference Summary and Report
NASA Astrophysics Data System (ADS)
Singal, J.; Haider, J.; Ajello, M.; Ballantyne, D. R.; Bunn, E.; Condon, J.; Dowell, J.; Fixsen, D.; Fornengo, N.; Harms, B.; Holder, G.; Jones, E.; Kellermann, K.; Kogut, A.; Linden, T.; Monsalve, R.; Mertsch, P.; Murphy, E.; Orlando, E.; Regis, M.; Scott, D.; Vernstrom, T.; Xu, L.
2018-03-01
We summarize the radio synchrotron background workshop that took place 2017 July 19–21 at the University of Richmond. This first scientific meeting dedicated to the topic was convened because current measurements of the diffuse radio monopole reveal a surface brightness that is several times higher than can be straightforwardly explained by known Galactic and extragalactic sources and processes, rendering it by far the least well understood photon background at present. It was the conclusion of a majority of the participants that the radio monopole level is at or near that reported by the ARCADE 2 experiment and inferred from several absolutely calibrated zero-level lower frequency radio measurements, and unanimously agreed that the production of this level of surface brightness, if confirmed, represents a major outstanding question in astrophysics. The workshop reached a consensus on the next priorities for investigations of the radio synchrotron background.
Energy Measurement Studies for CO2 Measurement with a Coherent Doppler Lidar System
NASA Technical Reports Server (NTRS)
Beyon, Jeffrey Y.; Koch, Grady J.; Vanvalkenburg, Randal L.; Yu, Jirong; Singh, Upendra N.; Kavaya, Michael J.
2010-01-01
The accurate measurement of energy in the application of lidar system for CO2 measurement is critical. Different techniques of energy estimation in the online and offline pulses are investigated for post processing of lidar returns. The cornerstone of the techniques is the accurate estimation of the spectrum of lidar signal and background noise. Since the background noise is not the ideal white Gaussian noise, simple average level estimation of noise level is not well fit in the energy estimation of lidar signal and noise. A brief review of the methods is presented in this paper.
Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting
Mace, Emily; Aalseth, Craig; Alexander, Tom; ...
2016-12-21
Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the beta decay spectra. In this paper, we present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120 mg of H 2O and present sensitivity results.
Process and apparatus for detecting presence of plant substances
Kirby, John A.
1991-01-01
An apparatus and process for detecting the presence of plant substances in a particular environment which comprises the steps of: measuring the background K40 gamma ray radiation level in a particular environment with a 1.46 MeV gamma ray counter system; measuring the amount of K40 gamma ray radiation emanating from a package containing a plant substance being passed through an environment with a counter; and generating an alarm signal when the total K40 gamma ray radiation reaches a predetermined level over and above the background level.
Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech.
Švec, Jan G; Granqvist, Svante
2018-03-15
Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
Low background screening capability in the UK
NASA Astrophysics Data System (ADS)
Ghag, Chamkaur
2015-08-01
Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screening and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.
Development of an underground HPGe array facility for ultra low radioactivity measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sala, E.; Kang, W. G.; Kim, Y. D.
Low Level Counting techniques using low background facilities are continuously under development to increase the possible sensitivity needed for rare physics events experiments. The CUP (Center for Underground Physics) group of IBS is developing, in collaboration with Canberra, a ultra low background instrument composed of two arrays facing each other with 7 HPGe detectors each. The low radioactive background of each detector has been evaluated and improved by the material selection of the detector components. Samples of all the building materials have been provided by the manufacturer and the contaminations had been measured using an optimized low background 100% HPGemore » with a dedicated shielding. The evaluation of the intrinsic background has been performed using MonteCarlo simulations and considering the contribution of each material with the measured contamination. To further reduce the background, the instrument will be placed in the new underground laboratory at YangYang exploiting the 700m mountain coverage and radon-free air supplying system. The array has been designed to perform various Ultra Low background measurements; the sensitivity we are expecting will allow not only low level measurements of Ra and Th contaminations in Copper or other usually pure materials, but also the search for rare decays. In particular some possible candidates and configurations to detect the 0νECEC (for example {sup 106}Cd and {sup 156}Dy) and rare β decays ({sup 96}Zr, {sup 180m}Ta , etc ) are under study.« less
Granularity of the Diffuse Background Observed
NASA Technical Reports Server (NTRS)
Gruber, D. E.; MacDonald, D.; Rothschild, R. E.; Boldt, E.; Mushotzky, R. F.; Fabian, A. C.
1995-01-01
First results are reported from a program for measuring the field-to-field fluctuation level of the cosmic diffuse background by using differences between the two background positions of each deep exposure with the High Energy X-ray Timing Experiment (HEXTE) instrument on the Remote X Ray Timing Explorer (RXTE). With 8 million live seconds accumulated to date a fluctuation level on the 15-25 keV band is observed which is consistent with extrapolations from the High Energy Astrophysical Observatory-1 (HEAO-1) measurements. Positive results are expected eventually at higher energies. Models of (active galactic nuclei) AGN origin will eventually be constrained by this program.
Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting.
Mace, Emily; Aalseth, Craig; Alexander, Tom; Back, Henning; Day, Anthony; Hoppe, Eric; Keillor, Martin; Moran, Jim; Overman, Cory; Panisko, Mark; Seifert, Allen
2017-08-01
Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the beta decay spectra. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120mg of H 2 O and present sensitivity results. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Allen, Christopher S.; Jaeger, Stephen; Soderman, Paul; Koga, Dennis (Technical Monitor)
1999-01-01
Background noise measurements were made of the acoustic environment in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The measurements were acquired subsequent to the 40x80 Aeroacoustic Modernization Project, which was undertaken to improve the anechoic characteristics of the 40x80's closed test section as well as reduce the levels of background noise in the facility. The resulting 40x80 anechoic environment was described by Soderman et. al., and the current paper describes the resulting 40x80 background noise, discusses the sources of the noise, and draws comparisons to previous 40x80 background noise levels measurements. At low wind speeds or low frequencies, the 40x80 background noise is dominated by the fan drive system. To obtain the lowest fan drive noise for a given tunnel condition, it is possible in the 40x80 to reduce the fans' rotational speed and adjust the fans' blade pitch, as described by Schmidtz et. al. This idea is not new, but has now been operationally implemented with modifications for increased power at low rotational speeds. At low to mid-frequencies and at higher wind speeds, the dominant noise mechanism was thought to be caused by the surface interface of the previous test section floor acoustic lining. In order to reduce this noise mechanism, the new test section floor lining was designed to resist the pumping of flow in and out of the space between the grating slats required to support heavy equipment. In addition, the lining/flow interface over the entire test section was designed to be smoother and quieter than the previous design. At high wind speeds or high frequencies, the dominant source of background noise in the 40x80 is believed to be caused by the response of the in-flow microphone probes (required by the nature of the closed test section) to the fluctuations in the freestream flow. The resulting background noise levels are also different for probes of various diameters and types. The inflow microphone support strut is also a source of background noise but this source's impact may be minimized by careful design of the strut. In the present paper, the mechanisms mentioned above are discussed in detail. Their frequency and velocity ranges of dominance are defined and the differences between past and current facility background noise levels are presented. This paper gives valuable information for those wishing to make acoustic measurements in the 40x80. With this report and an estimate of the noise levels produced by the noise source of interest, it should be possible to determine the signal-to-noise ratios and measurement locations to successfully perform aeroacoustic testing in the NASA Ames Research Center's 40- by 80-Foot Wind Tunnel.
Background radiation measurements at high power research reactors
Ashenfelter, J.; Yeh, M.; Balantekin, B.; ...
2015-10-23
Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including γ-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the backgroundmore » fields encountered. Furthermore, the general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.« less
Speaking up: Killer whales (Orcinus orca) increase their call amplitude in response to vessel noise.
Holt, Marla M; Noren, Dawn P; Veirs, Val; Emmons, Candice K; Veirs, Scott
2009-01-01
This study investigated the effects of anthropogenic sound exposure on the vocal behavior of free-ranging killer whales. Endangered Southern Resident killer whales inhabit areas including the urban coastal waters of Puget Sound near Seattle, WA, where anthropogenic sounds are ubiquitous, particularly those from motorized vessels. A calibrated recording system was used to measure killer whale call source levels and background noise levels (1-40 kHz). Results show that whales increased their call amplitude by 1 dB for every 1 dB increase in background noise levels. Furthermore, nearby vessel counts were positively correlated with these observed background noise levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghag, Chamkaur
Low background rare event searches in underground laboratories seeking observation of direct dark matter interactions or neutrino-less double beta decay have the potential to profoundly advance our understanding of the physical universe. Successful results from these experiments depend critically on construction from extremely radiologically clean materials and accurate knowledge of subsequent low levels of expected background. The experiments must conduct comprehensive screening campaigns to reduce radioactivity from detector components, and these measurements also inform detailed characterisation and quantification of background sources and their impact, necessary to assign statistical significance to any potential discovery. To provide requisite sensitivity for material screeningmore » and characterisation in the UK to support our rare event search activities, we have re-developed our infrastructure to add ultra-low background capability across a range of complementary techniques that collectively allow complete radioactivity measurements. Ultra-low background HPGe and BEGe detectors have been installed at the Boulby Underground Laboratory, itself undergoing substantial facility re-furbishment, to provide high sensitivity gamma spectroscopy in particular for measuring the uranium and thorium decay series products. Dedicated low-activity mass spectrometry instrumentation has been developed at UCL for part per trillion level contaminant identification to complement underground screening with direct U and Th measurements, and meet throughput demands. Finally, radon emanation screening at UCL measures radon background inaccessible to gamma or mass spectrometry techniques. With this new capability the UK is delivering half of the radioactivity screening for the LZ dark matter search experiment.« less
Background levels of methane in Mars’ atmosphere show strong seasonal variations
NASA Astrophysics Data System (ADS)
Webster, Christopher R.; Mahaffy, Paul R.; Atreya, Sushil K.; Moores, John E.; Flesch, Gregory J.; Malespin, Charles; McKay, Christopher P.; Martinez, German; Smith, Christina L.; Martin-Torres, Javier; Gomez-Elvira, Javier; Zorzano, Maria-Paz; Wong, Michael H.; Trainer, Melissa G.; Steele, Andrew; Archer, Doug; Sutter, Brad; Coll, Patrice J.; Freissinet, Caroline; Meslin, Pierre-Yves; Gough, Raina V.; House, Christopher H.; Pavlov, Alexander; Eigenbrode, Jennifer L.; Glavin, Daniel P.; Pearson, John C.; Keymeulen, Didier; Christensen, Lance E.; Schwenzer, Susanne P.; Navarro-Gonzalez, Rafael; Pla-García, Jorge; Rafkin, Scot C. R.; Vicente-Retortillo, Álvaro; Kahanpää, Henrik; Viudez-Moreiras, Daniel; Smith, Michael D.; Harri, Ari-Matti; Genzer, Maria; Hassler, Donald M.; Lemmon, Mark; Crisp, Joy; Sander, Stanley P.; Zurek, Richard W.; Vasavada, Ashwin R.
2018-06-01
Variable levels of methane in the martian atmosphere have eluded explanation partly because the measurements are not repeatable in time or location. We report in situ measurements at Gale crater made over a 5-year period by the Tunable Laser Spectrometer on the Curiosity rover. The background levels of methane have a mean value 0.41 ± 0.16 parts per billion by volume (ppbv) (95% confidence interval) and exhibit a strong, repeatable seasonal variation (0.24 to 0.65 ppbv). This variation is greater than that predicted from either ultraviolet degradation of impact-delivered organics on the surface or from the annual surface pressure cycle. The large seasonal variation in the background and occurrences of higher temporary spikes (~7 ppbv) are consistent with small localized sources of methane released from martian surface or subsurface reservoirs.
A method for Removing Surface Contamination on Ultra-pure Copper Spectrometer Components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoppe, Eric W.; Seifert, Allen; Aalseth, Craig E.
Spectrometers for the lowest-level radiometric measurements require materials of extreme radiopurity. Measurements of rare nuclear decays, e.g. neutrinoless double-beta decay, can require construction and shielding materials with bulk radiopurity reaching one micro-Becquerel per kilogram or less. When such extreme material purity is achieved, surface contamination, particularly solid daughters in the natural radon decay chains, can become the limiting background. High-purity copper is an important material for ultra-low-background spectrometers and thus is the focus of this work. A method for removing surface contamination at very low levels without attacking the bulk material is described. An assay method using a low-background proportionalmore » counter made of the material under examination is employed, and the resulting preliminary result of achievable surface contamination levels is presented.« less
Using Music as a Background for Reading: An Exploratory Study.
ERIC Educational Resources Information Center
Mulliken, Colleen N.; Henk, William A.
1985-01-01
Reports on a study during which intermediate level students were exposed to three auditory backgrounds while reading (no music, classical music, and rock music), and their subsequent comprehension performance was measured. Concludes that the auditory background during reading may affect comprehension and that, for most students, rock music should…
Investigation of background radiation levels and geologic unit profiles in Durango, Colorado
DOE Office of Scientific and Technical Information (OSTI.GOV)
Triplett, G.H.; Foutz, W.L.; Lesperance, L.R.
1989-11-01
As part of the Uranium Mill Tailings Remedial Action (UMTRA) Project, Oak Ridge National Laboratory (ORNL) has performed radiological surveys on 435 vicinity properties (VPs) in the Durango area. This study was undertaken to establish the background radiation levels and geologic unit profiles in the Durango VP area. During the months of May through June, 1986, extensive radiometric measurements and surface soil samples were collected in the Durango VP area by personnel from ORNL's Grand Junction Office. A majority of the Durango VP surveys were conducted at sites underlain by Quaternary alluvium, older Quaternary gravels, and Cretaceous Lewis and Mancosmore » shales. These four geologic units were selected to be evaluated. The data indicated no formation anomalies and established regional background radiation levels. Durango background radionuclide concentrations in surface soil were determined to be 20.3 {plus minus} 3.4 pCi/g for {sup 40}K, 1.6 {plus minus} 0.5 pCi/g for {sup 226}Ra, and 1.2 {plus minus} 0.3 pCi/g for {sup 232}Th. The Durango background gamma exposure rate was found to be 16.5 {plus minus} 1.3 {mu}R/h. Average gamma spectral count rate measurements for {sup 40}K, {sup 226}Ra and {sup 232}Th were determined to be 553, 150, and 98 counts per minute (cpm), respectively. Geologic unit profiles and Durango background radiation measurements are presented and compared with other areas. 19 refs., 15 figs., 5 tabs.« less
Advantages of binaural amplification to acceptable noise level of directional hearing aid users.
Kim, Ja-Hee; Lee, Jae Hee; Lee, Ho-Ki
2014-06-01
The goal of the present study was to examine whether Acceptable Noise Levels (ANLs) would be lower (greater acceptance of noise) in binaural listening than in monaural listening condition and also whether meaningfulness of background speech noise would affect ANLs for directional microphone hearing aid users. In addition, any relationships between the individual binaural benefits on ANLs and the individuals' demographic information were investigated. Fourteen hearing aid users (mean age, 64 years) participated for experimental testing. For the ANL calculation, listeners' most comfortable listening levels and background noise level were measured. Using Korean ANL material, ANLs of all participants were evaluated under monaural and binaural amplification with a counterbalanced order. The ANLs were also compared across five types of competing speech noises, consisting of 1- through 8-talker background speech maskers. Seven young normal-hearing listeners (mean age, 27 years) participated for the same measurements as a pilot testing. The results demonstrated that directional hearing aid users accepted more noise (lower ANLs) with binaural amplification than with monaural amplification, regardless of the type of competing speech. When the background speech noise became more meaningful, hearing-impaired listeners accepted less amount of noise (higher ANLs), revealing that ANL is dependent on the intelligibility of the competing speech. The individuals' binaural advantages in ANLs were significantly greater for the listeners with longer experience of hearing aids, yet not related to their age or hearing thresholds. Binaural directional microphone processing allowed hearing aid users to accept a greater amount of background noise, which may in turn improve listeners' hearing aid success. Informational masking substantially influenced background noise acceptance. Given a significant association between ANLs and duration of hearing aid usage, ANL measurement can be useful for clinical counseling of binaural hearing aid candidates or unsuccessful users.
NASA Technical Reports Server (NTRS)
Hoad, D. R.; Martin, R. M.
1985-01-01
Many open jet wind tunnels experience pulsations of the flow which are typically characterized by periodic low frequency velocity and pressure variations. One method of reducing these fluctuations is to install vanes around the perimeter of the jet exit to protrude into the flow. Although these vanes were shown to be effective in reducing the fluctuation content, they can also increase the test section background noise level. The results of an experimental acoustic program in the Langley 4- by 7-Meter Tunnel is presented which evaluates the effect on tunnel background noise of such modifications to the jet exit nozzle. Noise levels for the baseline tunnel configuration are compared with those for three jet exit nozzle modifications, including an enhanced noise reduction configuration that minimizes the effect of the vanes on the background noise. Although the noise levels for this modified vane configuration were comparable to baseline tunnel background noise levels in this facility, installation of these modified vanes in an acoustic tunnel may be of concern because the noise levels for the vanes could be well above background noise levels in a quiet facility.
Hill, Shannon B; Faradzhev, Nadir S; Powell, Cedric J
2017-12-01
We discuss the problem of quantifying common sources of statistical uncertainties for analyses of trace levels of surface contamination using X-ray photoelectron spectroscopy. We examine the propagation of error for peak-area measurements using common forms of linear and polynomial background subtraction including the correlation of points used to determine both background and peak areas. This correlation has been neglected in previous analyses, but we show that it contributes significantly to the peak-area uncertainty near the detection limit. We introduce the concept of relative background subtraction variance (RBSV) which quantifies the uncertainty introduced by the method of background determination relative to the uncertainty of the background area itself. The uncertainties of the peak area and atomic concentration and of the detection limit are expressed using the RBSV, which separates the contributions from the acquisition parameters, the background-determination method, and the properties of the measured spectrum. These results are then combined to find acquisition strategies that minimize the total measurement time needed to achieve a desired detection limit or atomic-percentage uncertainty for a particular trace element. Minimization of data-acquisition time is important for samples that are sensitive to x-ray dose and also for laboratories that need to optimize throughput.
Sources and levels of background noise in the NASA Ames 40- by 80-foot wind tunnel
NASA Technical Reports Server (NTRS)
Soderman, Paul T.
1988-01-01
Background noise levels are measured in the NASA Ames Research Center 40- by 80-Foot Wind Tunnel following installation of a sound-absorbent lining on the test-section walls. Results show that the fan-drive noise dominated the empty test-section background noise at airspeeds below 120 knots. Above 120 knots, the test-section broadband background noise was dominated by wind-induced dipole noise (except at lower harmonics of fan blade-passage tones) most likely generated at the microphone or microphone support strut. Third-octave band and narrow-band spectra are presented for several fan operating conditions and test-section airspeeds. The background noise levels can be reduced by making improvements to the microphone wind screen or support strut. Empirical equations are presented relating variations of fan noise with fan speed or blade-pitch angle. An empirical expression for typical fan noise spectra is also presented. Fan motor electric power consumption is related to the noise generation. Preliminary measurements of sound absorption by the test-section lining indicate that the 152 mm thick lining will adequately absorb test-section model noise at frequencies above 300 Hz.
Development of a low background liquid scintillation counter for a shallow underground laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.
2015-08-20
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunitymore » for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Archer, Daniel E.; Hornback, Donald Eric; Johnson, Jeffrey O.
This report summarizes the findings of a two year effort to systematically assess neutron and gamma backgrounds relevant to operational modeling and detection technology implementation. The first year effort focused on reviewing the origins of background sources and their impact on measured rates in operational scenarios of interest. The second year has focused on the assessment of detector and algorithm performance as they pertain to operational requirements against the various background sources and background levels.
Tanaka, Yoshiki; Yokoyama, Sho; Horai, Rie; Kojima, Takashi; Hiroyuki, Sato; Kato, Yukihito; Takagi, Mari; Nakamura, Hideki; Tanaka, Kiyoshi; Ichikawa, Kazuo; Tanabe, Shoko
2018-03-01
To evaluate the color visual acuity (CVA) of young healthy subjects using colored Landolt rings and the effect of background luminance level on the CVA. We measured the CVA of 20 young healthy subjects (age: 23.8 ± 3.8 years) with different colors using a computer and a liquid crystal display, with 15 Landolt ring colors (30 cd/m 2 ) with a background luminance of 30 cd/m 2 , and then 100 cd/m 2 . We then used different background luminance levels (15-50 cd/m 2 ) using four Landolt ring colors (red, green-yellow, green, and blue-green) to evaluate the effect of the background luminance level on CVA. The CVA significantly differed among the colors with a background luminance of 30 cd/m 2 (p < 0.0001). Green-yellow and blue-purple had poor CVA (high LogMAR value; 0.808 ± 0.107 and 0.633 ± 0.150, respectively) with a background luminance of 30 cd/m 2 (same luminance as the Landolt rings). There were no significant differences in the CVAs among the colors with a background luminance of 100 cd/m 2 (p = 0.5999). There were no significant difference in the CVA between background luminance 30 cd/m 2 and other luminance level ranging from 28 to 32 cd/m 2 for colors of red, green-yellow, green, and blue-green. The results reveal that the background luminance of Landolt rings affects the CVA. Distinctive CVAs for each color are measured by equalizing the luminance between the Landolt ring and the background. We consider that the poor CVAs of these colors reflect the visual function of S-cone, because GY and BP are included in the confusion locus of tritan axis on the chromaticity diagram. We believe that CVA assessment may be useful for individuals who have known or suspected ocular dysfunction or color vision deficiencies.
Shielding concepts for low-background proportional counter arrays in surface laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aalseth, Craig E.; Humble, Paul H.; Mace, Emily K.
2016-02-01
Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes – primarily and activity in the uranium and thorium decay chains – inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportionalmore » counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as 37Ar.« less
Below-Background Ionizing Radiation as an Environmental Cue for Bacteria
Castillo, Hugo; Smith, Geoffrey B.
2017-02-14
All organisms on earth grow under the influence of a natural and relatively constant dose of ionizing radiation referred to as background radiation, and so cells have different mechanisms to prevent the accumulation of damage caused by its different components. However, current knowledge of the deleterious effects of radiation on cells is based on the exposure to acute and high or to chronic, above background doses of radiation and therefore is not appropriate to explain the cellular and biochemical mechanisms that cells employ to sense and respond to chronic below-background levels. Studies at below-background radiation doses can provide insight intomore » the biological role of radiation, as suggested by several examples of what appears to be a stress response in cells grown at doses that range from 10 to 79 times lower than background. Here, we discuss some of the technical constraints to shield cells from radiation to below-background levels, as well as different approaches used to detect and measure responses to such unusual environmental conditions. Then, we present data from Shewanella oneidensis and Deinococcus radiodurans experiments that show how two taxonomically distant bacterial species sense and respond to unnaturally low levels of radiation. Finally, in brief, we grew S. oneidensis and D. radiodurans in liquid culture at dose rates of 72.05 (control) and 0.91 (treatment) nGy hr -1 (including radon) for up to 72 h and measured cell density and the expression of stress-related genes. Our results suggest that a stress response is triggered in the absence of normal levels of radiation.« less
Below-Background Ionizing Radiation as an Environmental Cue for Bacteria
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castillo, Hugo; Smith, Geoffrey B.
All organisms on earth grow under the influence of a natural and relatively constant dose of ionizing radiation referred to as background radiation, and so cells have different mechanisms to prevent the accumulation of damage caused by its different components. However, current knowledge of the deleterious effects of radiation on cells is based on the exposure to acute and high or to chronic, above background doses of radiation and therefore is not appropriate to explain the cellular and biochemical mechanisms that cells employ to sense and respond to chronic below-background levels. Studies at below-background radiation doses can provide insight intomore » the biological role of radiation, as suggested by several examples of what appears to be a stress response in cells grown at doses that range from 10 to 79 times lower than background. Here, we discuss some of the technical constraints to shield cells from radiation to below-background levels, as well as different approaches used to detect and measure responses to such unusual environmental conditions. Then, we present data from Shewanella oneidensis and Deinococcus radiodurans experiments that show how two taxonomically distant bacterial species sense and respond to unnaturally low levels of radiation. Finally, in brief, we grew S. oneidensis and D. radiodurans in liquid culture at dose rates of 72.05 (control) and 0.91 (treatment) nGy hr -1 (including radon) for up to 72 h and measured cell density and the expression of stress-related genes. Our results suggest that a stress response is triggered in the absence of normal levels of radiation.« less
Discriminability measures for predicting readability of text on textured backgrounds
NASA Technical Reports Server (NTRS)
Scharff, L. F.; Hill, A. L.; Ahumada, A. J. Jr; Watson, A. B. (Principal Investigator)
2000-01-01
Several discriminability measures were examined for their ability to predict reading search times for three levels of text contrast and a range of backgrounds (plain, a periodic texture, and four spatial-frequency-filtered textures created from the periodic texture). Search times indicate that these background variations only affect readability when the text contrast is low, and that spatial frequency content of the background affects readability. These results were not well predicted by the single variables of text contrast (Spearman rank correlation = -0.64) and background RMS contrast (0.08), but a global masking index and a spatial-frequency-selective masking index led to better predictions (-0.84 and -0.81, respectively). c2000 Optical Society of America.
Schaufele, Fred
2013-01-01
Förster resonance energy transfer (FRET) between fluorescent proteins (FPs) provides insights into the proximities and orientations of FPs as surrogates of the biochemical interactions and structures of the factors to which the FPs are genetically fused. As powerful as FRET methods are, technical issues have impeded their broad adoption in the biologic sciences. One hurdle to accurate and reproducible FRET microscopy measurement stems from variable fluorescence backgrounds both within a field and between different fields. Those variations introduce errors into the precise quantification of fluorescence levels on which the quantitative accuracy of FRET measurement is highly dependent. This measurement error is particularly problematic for screening campaigns since minimal well-to-well variation is necessary to faithfully identify wells with altered values. High content screening depends also upon maximizing the numbers of cells imaged, which is best achieved by low magnification high throughput microscopy. But, low magnification introduces flat-field correction issues that degrade the accuracy of background correction to cause poor reproducibility in FRET measurement. For live cell imaging, fluorescence of cell culture media in the fluorescence collection channels for the FPs commonly used for FRET analysis is a high source of background error. These signal-to-noise problems are compounded by the desire to express proteins at biologically meaningful levels that may only be marginally above the strong fluorescence background. Here, techniques are presented that correct for background fluctuations. Accurate calculation of FRET is realized even from images in which a non-flat background is 10-fold higher than the signal. PMID:23927839
ERIC Educational Resources Information Center
Dairo, Yetunde M.; Collett, Johnny; Dawes, Helen
2017-01-01
Background: Few studies have measured physical activity (PA) levels of adults with intellectual disabilities using both objective and subjective methods, but none included individuals with profound intellectual disabilities. To inform effective measurement of PA across the disability spectrum, this study explored: the feasibility of measuring PA…
In-mine testing of a natural background sensor, part B
NASA Technical Reports Server (NTRS)
Martzloff, F. D.
1981-01-01
The capability of a natural background sensor for measuring the thickness of top coal on a longwall face was examined. The limitations on the time during which tests could be performed, and the roof conditions, did not produce readings of top coal measurements during the shearer operation. It was demonstrated that the system is capable to survive operating conditions in the mine environment, while the static tests confirmed that the natural background sensor approach is a valid method of measuring top coal thickness in mines where the roof rock provides a constant radiation level. It is concluded that the practical results will improve sequent development of an integrated vertical control system which is information from the natural background system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vacri, M. L. di; Nisi, S.; Balata, M.
2013-08-08
The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Levelmore » Assay) of the LNGS underground lab using HPGe detectors.« less
Large-scale analysis of tumor necrosis factor α levels in systemic lupus erythematosus.
Weckerle, Corinna E; Mangale, Dorothy; Franek, Beverly S; Kelly, Jennifer A; Kumabe, Marissa; James, Judith A; Moser, Kathy L; Harley, John B; Niewold, Timothy B
2012-09-01
Systemic lupus erythematosus (SLE) disease manifestations are highly variable among patients, and the prevalence of individual clinical features differs significantly by ancestry. Serum tumor necrosis factor α (TNFα) levels are elevated in some SLE patients and may play a role in disease pathogenesis. The aim of this study was to look for associations between serum TNFα levels, clinical manifestations of SLE, autoantibodies, and serum interferon-α (IFNα) levels in a large multiancestral SLE cohort. We studied serum TNFα levels in 653 SLE patients (214 African Americans, 298 European Americans, and 141 Hispanic Americans). TNFα was measured using an enzyme-linked immunosorbent assay, and IFNα was measured with a functional reporter cell assay. Stratified and multivariate analyses were used to detect associations in each ancestral background separately, with meta-analysis when appropriate. Serum TNFα levels were significantly higher in SLE patients than in non-autoimmune disease controls (P < 5.0 × 10(-3) for each ancestral background). High serum TNFα levels were positively correlated with high serum IFNα levels when tested in the same sample across all ancestral backgrounds (odds ratio range 1.76-1.86, P = 4.8 × 10(-3) by Fisher's combined probability test). While serum TNFα levels alone did not differ significantly among SLE patients of different ancestral backgrounds, the proportion of patients with concurrently high levels of TNFα and IFNα was highest in African Americans and lowest in European Americans (P = 5.0 × 10(-3) ). Serum TNFα levels were not associated with autoantibodies, clinical criteria for the diagnosis of SLE, or age at the time of sampling. Serum TNFα levels are high in many SLE patients, and we observed a positive correlation between serum TNFα and IFNα levels. These data support a role for TNFα in the pathogenesis of SLE across all ancestral backgrounds and suggest important cytokine subgroups within the disease. Copyright © 2012 by the American College of Rheumatology.
Snellings, André; Sagher, Oren; Anderson, David J; Aldridge, J Wayne
2009-10-01
The authors developed a wavelet-based measure for quantitative assessment of neural background activity during intraoperative neurophysiological recordings so that the boundaries of the subthalamic nucleus (STN) can be more easily localized for electrode implantation. Neural electrophysiological data were recorded in 14 patients (20 tracks and 275 individual recording sites) with dopamine-sensitive idiopathic Parkinson disease during the target localization portion of deep brain stimulator implantation surgery. During intraoperative recording, the STN was identified based on audio and visual monitoring of neural firing patterns, kinesthetic tests, and comparisons between neural behavior and the known characteristics of the target nucleus. The quantitative wavelet-based measure was applied offline using commercially available software to measure the magnitude of the neural background activity, and the results of this analysis were compared with the intraoperative conclusions. Wavelet-derived estimates were also compared with power spectral density measurements. The wavelet-derived background levels were significantly higher in regions encompassed by the clinically estimated boundaries of the STN than in the surrounding regions (STN, 225 +/- 61 microV; ventral to the STN, 112 +/- 32 microV; and dorsal to the STN, 136 +/- 66 microV). In every track, the absolute maximum magnitude was found within the clinically identified STN. The wavelet-derived background levels provided a more consistent index with less variability than measurements with power spectral density. Wavelet-derived background activity can be calculated quickly, does not require spike sorting, and can be used to identify the STN reliably with very little subjective interpretation required. This method may facilitate the rapid intraoperative identification of STN borders.
Autonomous rock detection on mars through region contrast
NASA Astrophysics Data System (ADS)
Xiao, Xueming; Cui, Hutao; Yao, Meibao; Tian, Yang
2017-08-01
In this paper, we present a new autonomous rock detection approach through region contrast. Unlike current state-of-art pixel-level rock segmenting methods, new method deals with this issue in region level, which will significantly reduce the computational cost. Image is firstly splitted into homogeneous regions based on intensity information and spatial layout. Considering the high-water memory constraints of onboard flight processor, only low-level features, average intensity and variation of superpixel, are measured. Region contrast is derived as the integration of intensity contrast and smoothness measurement. Rocks are then segmented from the resulting contrast map by an adaptive threshold. Since the merely intensity-based method may cause false detection in background areas with different illuminations from surroundings, a more reliable method is further proposed by introducing spatial factor and background similarity to the region contrast. Spatial factor demonstrates the locality of contrast, while background similarity calculates the probability of each subregion belonging to background. Our method is efficient in dealing with large images and only few parameters are needed. Preliminary experimental results show that our algorithm outperforms edge-based methods in various grayscale rover images.
Veira, Andreas; Jackson, Peter L; Ainslie, Bruce; Fudge, Dennis
2013-07-01
This study investigates the development and application of a simple method to calculate annual and seasonal PM2.5 and PM10 background concentrations in small cities and rural areas. The Low Pollution Sectors and Conditions (LPSC) method is based on existing measured long-term data sets and is designed for locations where particulate matter (PM) monitors are only influenced by local anthropogenic emission sources from particular wind sectors. The LPSC method combines the analysis of measured hourly meteorological data, PM concentrations, and geographical emission source distributions. PM background levels emerge from measured data for specific wind conditions, where air parcel trajectories measured at a monitoring station are assumed to have passed over geographic sectors with negligible local emissions. Seasonal and annual background levels were estimated for two monitoring stations in Prince George, Canada, and the method was also applied to four other small cities (Burns Lake, Houston, Quesnel, Smithers) in northern British Columbia. The analysis showed reasonable background concentrations for both monitoring stations in Prince George, whereas annual PM10 background concentrations at two of the other locations and PM2.5 background concentrations at one other location were implausibly high. For those locations where the LPSC method was successful, annual background levels ranged between 1.8 +/- 0.1 microg/m3 and 2.5 +/- 0.1 microg/m3 for PM2.5 and between 6.3 +/- 0.3 microg/m3 and 8.5 +/- 0.3 microg/m3 for PM10. Precipitation effects and patterns of seasonal variability in the estimated background concentrations were detectable for all locations where the method was successful. Overall the method was dependent on the configuration of local geography and sources with respect to the monitoring location, and may fail at some locations and under some conditions. Where applicable, the LPSC method can provide a fast and cost-efficient way to estimate background PM concentrations for small cities in sparsely populated regions like northern British Columbia. In rural areas like northern British Columbia, particulate matter (PM) monitoring stations are usually located close to emission sources and residential areas in order to assess the PM impact on human health. Thus there is a lack of accurate PM background concentration data that represent PM ambient concentrations in the absence of local emissions. The background calculation method developed in this study uses observed meteorological data as well as local source emission locations and provides annual, seasonal and precipitation-related PM background concentrations that are comparable to literature values for four out of six monitoring stations.
Temporal trends in and influence of wind on PAH concentrations measured near the Great Lakes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cortes, D.R.; Basu, I.; Sweet, C.W.
2000-02-01
This paper reports on temporal trends in gas- and particle-phase PAH concentrations measured at three sites in the Great Lakes' Integrated Atmospheric Deposition Network: Eagle Harbor, near Lake Superior, Sleeping Bear Dunes, near Lake Michigan, and Sturgeon Point, near Lake Erie. While gas-phase concentrations have been decreasing since 1991 at all sites, particle-phase concentrations have been decreasing only at Sleeping Bear Dunes. To determine whether these results represent trends in background levels or regional emissions, the average concentrations are compared to those found in urban and rural studies. In addition, the influence of local wind direction on PAH concentrations ismore » investigated, with the assumption that dependence on wind direction implies regional sources. Using these two methods, it is found that PAH concentrations at Eagle Harbor and Sleeping Bear Dunes represent regional background levels but that PAH from the Buffalo Region intrude on the background levels measured at the Sturgeon Point site. At this site, wind from over Lake Erie reduces local PAH concentrations.« less
Background compensation for a radiation level monitor
Keefe, D.J.
1975-12-01
Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.
Background Noise Analysis in a Few-Photon-Level Qubit Memory
NASA Astrophysics Data System (ADS)
Mittiga, Thomas; Kupchak, Connor; Jordaan, Bertus; Namazi, Mehdi; Nolleke, Christian; Figeroa, Eden
2014-05-01
We have developed an Electromagnetically Induced Transparency based polarization qubit memory. The device is composed of a dual-rail probe field polarization setup colinear with an intense control field to store and retrieve any arbitrary polarization state by addressing a Λ-type energy level scheme in a 87Rb vapor cell. To achieve a signal-to-background ratio at the few photon level sufficient for polarization tomography of the retrieved state, the intense control field is filtered out through an etalon filtrating system. We have developed an analytical model predicting the influence of the signal-to-background ratio on the fidelities and compared it to experimental data. Experimentally measured global fidelities have been found to follow closely the theoretical prediction as signal-to-background decreases. These results suggest the plausibility of employing room temperature memories to store photonic qubits at the single photon level and for future applications in long distance quantum communication schemes.
Influence of the steady background turbulence level on second sound dynamics in He II II
NASA Astrophysics Data System (ADS)
Dalban-Canassy, M.; Hilton, D. K.; Sciver, S. W. Van
2007-01-01
We report complementary results to our previous publication [Dalban-Canassy M, Hilton DK, Van Sciver SW. Influence of the steady background turbulence level on second sound dynamics in He II. Adv Cryo Eng 2006;51:371-8], both of which are aimed at determining the influence of background turbulence on the breakpoint energy of second sound pulses in He II. The apparatus consists of a channel 175 mm long and 242 mm 2 in cross section immersed in a saturated bath of He II at 1.7 K. A heater at the bottom end generates both background turbulence, through a low level steady heat flux (up to qs = 2.6 kW/m 2), and high intensity square second sound pulses ( qp = 100 or 200 kW/m 2) of variable duration Δ t0 (up to 1 ms). Two superconducting filament sensors, located 25.4 mm and 127 mm above the heater, measure the temperature profiles of the traveling pulses. We present here an analysis of the measurements gathered on the top sensor, and compare them to similar results for the bottom sensor [1]. The strong dependence of the breakpoint energy on the background heat flux previously illustrated is also observed on the top sensor. The present work shows that the ratio of energy received at the top sensor to that at the bottom sensor diminishes with increasing background heat flux.
Cosmic microwave background dipole spectrum measured by the COBE FIRAS instrument
NASA Technical Reports Server (NTRS)
Fixsen, D. J.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Isaacman, R. B.; Mather, J. C.; Meyer, S. S.; Noerdlinger, P. D.; Shafer, R. A.; Weiss, R.
1994-01-01
The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) has determined the dipole spectrum of the cosmic microwave background radiation (CMBR) from 2 to 20/cm. For each frequency the signal is decomposed by fitting to a monopole, a dipole, and a Galactic template for approximately 60% of the sky. The overall dipole spectrum fits the derivative of a Planck function with an amplitude of 3.343 +/- 0.016 mK (95% confidence level), a temperature of 2.714 +/- 0.022 K (95% confidence level), and an rms deviation of 6 x 10(exp -9) ergs/sq cm/s/sr cm limited by a detector and cosmic-ray noise. The monopole temperature is consistent with that determined by direct measurement in the accompanying article by Mather et al.
Iodine-129 measurements in soil samples from Dolon village near the Semipalatinsk nuclear test site.
Endo, Satoru; Tomita, Junpei; Tanaka, Kenichi; Yamamoto, Masayoshi; Fukutani, Satoshi; Imanaka, Tetsuji; Sakaguchi, Aya; Amano, Hikaru; Kawamura, Hidehisa; Kawamura, Hisao; Apsalikov, Kazbek N; Gusev, Boris I; Whitehead, Neil E; Shinkarev, Sergey; Hoshi, Masaharu
2008-07-01
Dolon village, located about 60 km from the border of the Semipalatinsk nuclear test site, is known to be heavily contaminated by the first USSR atomic bomb test in August 1949. Soil samples around Dolon were taken in October 2005 in an attempt to evaluate internal thyroid dose arising from incorporation of radioiodine isotopes (mainly (131)I). Iodine-129 in soil was measured by using the technique of accelerator mass spectrometry. The (129)I/(127)I atom ratios measured were in the range from 3.3 x 10(-9) to 3.3 x 10(-7). These values were within the range of the current background level ( approximately 10(-9) to 10(-7)) in the environment, including contributions from the global fallout of atmospheric nuclear tests and local fallout of nuclear facilities. The (129)I atom accumulated level in soil ranged from 1.28 x 10(13) to 1.59 x 10(14) atoms m(-2), the average (8.0 x 10(13)) of which was higher than the background level of (2-5) x 10(13). From the relationship between (129)I and( 137)Cs (corrected for background and decay from 1949 to 2005) accumulated levels, the background level of (129)I and the (129)I/(137)Cs ratio around Dolon were estimated to be (6.4 +/- 0.4) x 10(13) atoms m(-2) and 0.25 +/- 0.16, respectively. This (129)I/(137)Cs ratio is almost similar to the fission yield ratio for (239)Pu fast fission (0.24).
Flow Quality Survey of the NASA Ames 11-by 11-Ft Transonic Wind Tunnel
NASA Technical Reports Server (NTRS)
Amaya, Max A.
2011-01-01
New baseline turbulence levels have been measured using a new CTA and new hot-wire sensors. Levels remain the same as measured in 1999. Data and methodology documented (almost). New baseline acoustics levels have been measured up to Mach 1.35. -Levels are higher than reported in 1999. -Data and methodology documented (almost). Application of fairings to the strut trailing edge showed up to a 10% reduction in the tunnel background noise. Data analysis and documentation for publishing is ongoing.
Aircraft and background noise annoyance effects
NASA Technical Reports Server (NTRS)
Willshire, K. F.
1984-01-01
To investigate annoyance of multiple noise sources, two experiments were conducted. The first experiment, which used 48 subjects, was designed to establish annoyance-noise level functions for three community noise sources presented individually: jet aircraft flyovers, air conditioner, and traffic. The second experiment, which used 216 subjects, investigated the effects of background noise on aircraft annoyance as a function of noise level and spectrum shape; and the differences between overall, aircraft, and background noise annoyance. In both experiments, rated annoyance was the dependent measure. Results indicate that the slope of the linear relationship between annoyance and noise level for traffic is significantly different from that of flyover and air conditioner noise and that further research was justified to determine the influence of the two background noises on overall, aircraft, and background noise annoyance (e.g., experiment two). In experiment two, total noise exposure, signal-to-noise ratio, and background source type were found to have effects on all three types of annoyance. Thus, both signal-to-noise ratio, and the background source must be considered when trying to determine community response to combined noise sources.
Snellings, André; Sagher, Oren; Anderson, David J.; Aldridge, J. Wayne
2016-01-01
Object A wavelet-based measure was developed to quantitatively assess neural background activity taken during surgical neurophysiological recordings to localize the boundaries of the subthalamic nucleus during target localization for deep brain stimulator implant surgery. Methods Neural electrophysiological data was recorded from 14 patients (20 tracks, n = 275 individual recording sites) with dopamine-sensitive idiopathic Parkinson’s disease during the target localization portion of deep brain stimulator implant surgery. During intraoperative recording the STN was identified based upon audio and visual monitoring of neural firing patterns, kinesthetic tests, and comparisons between neural behavior and known characteristics of the target nucleus. The quantitative wavelet-based measure was applied off-line using MATLAB software to measure the magnitude of the neural background activity, and the results of this analysis were compared to the intraoperative conclusions. Wavelet-derived estimates were compared to power spectral density measures. Results The wavelet-derived background levels were significantly higher in regions encompassed by the clinically estimated boundaries of the STN than in surrounding regions (STN: 225 ± 61 μV vs. ventral to STN: 112 ± 32 μV, and dorsal to STN: 136 ± 66 μV). In every track, the absolute maximum magnitude was found within the clinically identified STN. The wavelet-derived background levels provided a more consistent index with less variability than power spectral density. Conclusions The wavelet-derived background activity assessor can be calculated quickly, requires no spike sorting, and can be reliably used to identify the STN with very little subjective interpretation required. This method may facilitate rapid intraoperative identification of subthalamic nucleus borders. PMID:19344225
Rodgers, G G; Tenzing, P; Clark, T D
2016-01-01
In light of an increasing trend in fish biology towards using static respirometry techniques without the inclusion of a mixing mechanism and without accurately accounting for the influence of microbial (background) respiration, this paper quantifies the effect of these approaches on the oxygen consumption rates (ṀO2 ) measured from juvenile barramundi Lates calcarifer (mean ± s.e. mass = 20·31 ± 0·81 g) and adult spiny chromis damselfish Acanthochromis polyacanthus (22·03 ± 2·53 g). Background respiration changed consistently and in a sigmoidal manner over time in the treatment with a mixing device (inline recirculation pump), whereas attempts to measure background respiration in the non-mixed treatment yielded highly variable estimates of ṀO2 that were probably artefacts due to the lack of water movement over the oxygen sensor during measurement periods. This had clear consequences when accounting for background respiration in the calculations of fish ṀO2 . Exclusion of a mixing device caused a significantly lower estimate of ṀO2 in both species and reduced the capacity to detect differences between individuals as well as differences within an individual over time. There was evidence to suggest that the magnitude of these effects was dependent on the spontaneous activity levels of the fish, as the difference between mixed and non-mixed treatments was more pronounced for L. calcarifer (sedentary) than for A. polyacanthus (more spontaneously active). It is clear that respirometry set-ups for sedentary species must contain a mixing device to prevent oxygen stratification inside the respirometer. While more active species may provide a higher level of water mixing during respirometry measurements and theoretically reduce the need for a mixing device, the level of mixing cannot be quantified and may change with diurnal cycles in activity. To ensure consistency across studies without relying on fish activity levels, and to enable accurate assessments of background respiration, it is recommended that all respirometry systems should include an appropriate mixing device. © 2016 The Fisheries Society of the British Isles.
Evaluation of background radiation dose contributions in the United Arab Emirates.
Goddard, Braden; Bosc, Emmanuel; Al Hasani, Sarra; Lloyd, Cody
2018-09-01
The natural background radiation consists of three main components; cosmic, terrestrial, and skyshine. Although there are currently methods available to measure the total dose rate from background radiation, no established methods exist that allow for the measurement of each component the background radiation. This analysis consists of a unique methodology in which the dose rate contribution from each component of the natural background radiation is measured and calculated. This project evaluates the natural background dose rate in the Abu Dhabi City region from all three of these components using the developed methodology. Evaluating and understanding the different components of background radiation provides a baseline allowing for the detection, and possibly attribution, of elevated radiation levels. Measurements using a high-pressure ion chamber with different shielding configurations and two offshore measurements provided dose rate information that were attributed to the different components of the background radiation. Additional spectral information was obtained using an HPGe detector to verify and quantify the presence of terrestrial radionuclides. By evaluating the dose rates of the different shielding configurations the comic, terrestrial, and skyshine contribution in the Abu Dhabi City region were determined to be 33.0 ± 1.7, 15.7 ± 2.5, and 2.4 ± 2.1 nSv/h, respectively. Copyright © 2018. Published by Elsevier Ltd.
49 CFR 227.121 - Recordkeeping.
Code of Federal Regulations, 2011 CFR
2011-10-01
... measurements of the background sound pressure levels in audiometric test rooms; (vi) The model and serial... designed so that the integrity of each record is maintained through appropriate levels of security such as...
Poisson mixture model for measurements using counting.
Miller, Guthrie; Justus, Alan; Vostrotin, Vadim; Dry, Donald; Bertelli, Luiz
2010-03-01
Starting with the basic Poisson statistical model of a counting measurement process, 'extraPoisson' variance or 'overdispersion' are included by assuming that the Poisson parameter representing the mean number of counts itself comes from another distribution. The Poisson parameter is assumed to be given by the quantity of interest in the inference process multiplied by a lognormally distributed normalising coefficient plus an additional lognormal background that might be correlated with the normalising coefficient (shared uncertainty). The example of lognormal environmental background in uranium urine data is discussed. An additional uncorrelated background is also included. The uncorrelated background is estimated from a background count measurement using Bayesian arguments. The rather complex formulas are validated using Monte Carlo. An analytical expression is obtained for the probability distribution of gross counts coming from the uncorrelated background, which allows straightforward calculation of a classical decision level in the form of a gross-count alarm point with a desired false-positive rate. The main purpose of this paper is to derive formulas for exact likelihood calculations in the case of various kinds of backgrounds.
NASA Technical Reports Server (NTRS)
Costanza, Bryan T.; Horne, William C.; Schery, S. D.; Babb, Alex T.
2011-01-01
The Aero-Physics Branch at NASA Ames Research Center utilizes a 32- by 48-inch subsonic wind tunnel for aerodynamics research. The feasibility of acquiring acoustic measurements with a phased microphone array was recently explored. Acoustic characterization of the wind tunnel was carried out with a floor-mounted 24-element array and two ceiling-mounted speakers. The minimum speaker level for accurate level measurement was evaluated for various tunnel speeds up to a Mach number of 0.15 and streamwise speaker locations. A variety of post-processing procedures, including conventional beamforming and deconvolutional processing such as TIDY, were used. The speaker measurements, with and without flow, were used to compare actual versus simulated in-flow speaker calibrations. Data for wind-off speaker sound and wind-on tunnel background noise were found valuable for predicting sound levels for which the speakers were detectable when the wind was on. Speaker sources were detectable 2 - 10 dB below the peak background noise level with conventional data processing. The effectiveness of background noise cross-spectral matrix subtraction was assessed and found to improve the detectability of test sound sources by approximately 10 dB over a wide frequency range.
Background levels of methane in Mars' atmosphere show strong seasonal variations.
Webster, Christopher R; Mahaffy, Paul R; Atreya, Sushil K; Moores, John E; Flesch, Gregory J; Malespin, Charles; McKay, Christopher P; Martinez, German; Smith, Christina L; Martin-Torres, Javier; Gomez-Elvira, Javier; Zorzano, Maria-Paz; Wong, Michael H; Trainer, Melissa G; Steele, Andrew; Archer, Doug; Sutter, Brad; Coll, Patrice J; Freissinet, Caroline; Meslin, Pierre-Yves; Gough, Raina V; House, Christopher H; Pavlov, Alexander; Eigenbrode, Jennifer L; Glavin, Daniel P; Pearson, John C; Keymeulen, Didier; Christensen, Lance E; Schwenzer, Susanne P; Navarro-Gonzalez, Rafael; Pla-García, Jorge; Rafkin, Scot C R; Vicente-Retortillo, Álvaro; Kahanpää, Henrik; Viudez-Moreiras, Daniel; Smith, Michael D; Harri, Ari-Matti; Genzer, Maria; Hassler, Donald M; Lemmon, Mark; Crisp, Joy; Sander, Stanley P; Zurek, Richard W; Vasavada, Ashwin R
2018-06-08
Variable levels of methane in the martian atmosphere have eluded explanation partly because the measurements are not repeatable in time or location. We report in situ measurements at Gale crater made over a 5-year period by the Tunable Laser Spectrometer on the Curiosity rover. The background levels of methane have a mean value 0.41 ± 0.16 parts per billion by volume (ppbv) (95% confidence interval) and exhibit a strong, repeatable seasonal variation (0.24 to 0.65 ppbv). This variation is greater than that predicted from either ultraviolet degradation of impact-delivered organics on the surface or from the annual surface pressure cycle. The large seasonal variation in the background and occurrences of higher temporary spikes (~7 ppbv) are consistent with small localized sources of methane released from martian surface or subsurface reservoirs. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.
Complete NLO corrections to W+W+ scattering and its irreducible background at the LHC
NASA Astrophysics Data System (ADS)
Biedermann, Benedikt; Denner, Ansgar; Pellen, Mathieu
2017-10-01
The process pp → μ +ν μ e+νejj receives several contributions of different orders in the strong and electroweak coupling constants. Using appropriate event selections, this process is dominated by vector-boson scattering (VBS) and has recently been measured at the LHC. It is thus of prime importance to estimate precisely each contribution. In this article we compute for the first time the full NLO QCD and electroweak corrections to VBS and its irreducible background processes with realistic experimental cuts. We do not rely on approximations but use complete amplitudes involving two different orders at tree level and three different orders at one-loop level. Since we take into account all interferences, at NLO level the corrections to the VBS process and to the QCD-induced irreducible background process contribute at the same orders. Hence the two processes cannot be unambiguously distinguished, and all contributions to the μ +ν μ e+νejj final state should be preferably measured together.
Serum concentrations of polychlorinated dibenzo-p-dioxins among ceramicists.
Demond, Avery; Jiang, Xiaohui; Broadwater, Kendra; Meeker, John; Luksemburg, William; Maier, Martha; Garabrant, David; Franzblau, Alfred
2015-01-01
Polychlorinated dibenzo-p-dioxins (PCDDs) occur naturally in ball clay at elevated concentrations. Thus, persons who habitually work with clay may be at risk for exposure to PCDDs. An earlier case report provided some evidence of elevated PCDD levels in serum for long-term hobby ceramicists; however, no previous study has measured serum dioxin concentrations among ceramicists. This study measured PCDD serum levels for 27 individuals involved in ceramics making. The average residual, defined as the average of the [log measured serum lipid concentration – log background serum lipid concentration], was calculated and then tested to determine whether it was significantly different from zero. The p-values for the average residuals indicated that the serum lipid concentrations for several PCDD congeners were elevated relative to background. The number of significant residuals increased dramatically if the background concentrations were adjusted to account for the fact that they were not contemporaneous with the measurements for the ceramicists. The ratio of the 1,2,3,6,7,8-HxCDD concentration to the 1,2,3,7,8,9-HxCDD concentration was greater than 1.0, unlike in ball clay, suggesting that although long-term working with ball clay elevates the PCDD levels in serum somewhat, it is not the predominant source of the PCDD body burden for ceramicists.
Acoustical evaluation of preschool classrooms
NASA Astrophysics Data System (ADS)
Yang, Wonyoung; Hodgson, Murray
2003-10-01
An investigation was made of the acoustical environments in the Berwick Preschool, Vancouver, in response to complaints by the teachers. Reverberation times (RT), background noise levels (BNL), and in-class sound levels (Leq) were measured for acoustical evaluation in the classrooms. With respect to the measured RT and BNL, none of the classrooms in the preschool were acceptable according to the criteria relevant to this study. A questionnaire was administered to the teachers to assess their subjective responses to the acoustical and nonacoustical environments of the classrooms. Teachers agreed that the nonacoustical environments in the classrooms were fair, but that the acoustical environments had problems. Eight different classroom configurations were simulated to improve the acoustical environments, using the CATT room acoustical simulation program. When the surface absorption was increased, both the RT and speech levels decreased. RASTI was dependent on the volumes of the classrooms when the background noise levels were high; however, it depended on the total absorption of the classrooms when the background noise levels were low. Ceiling heights are critical as well. It is recommended that decreasing the volume of the classrooms is effective. Sound absorptive materials should be added to the walls or ceiling.
Design of a multiband near-infrared sky brightness monitor using an InSb detector.
Dong, Shu-Cheng; Wang, Jian; Tang, Qi-Jie; Jiang, Feng-Xin; Chen, Jin-Ting; Zhang, Yi-Hao; Wang, Zhi-Yue; Chen, Jie; Zhang, Hong-Fei; Jiang, Hai-Jiao; Zhu, Qing-Feng; Jiang, Peng; Ji, Tuo
2018-02-01
Infrared sky background level is an important parameter of infrared astronomy observations from the ground, particularly for a candidate site of an infrared capable observatory since low background level is required for such a site. The Chinese astronomical community is looking for a suitable site for a future 12 m telescope, which is designed for working in both optical and infrared wavelengths. However, none of the proposed sites has been tested for infrared observations. Nevertheless, infrared sky background measurements are also important during the design of infrared observing instruments. Based on the requirement, in order to supplement the current site survey data and guide the design of future infrared instruments, a multiband near-infrared sky brightness monitor (MNISBM) based on an InSb sensor is designed in this paper. The MNISBM consists of an optical system, mechanical structure and control system, detector and cooler, high gain readout electronics, and operational software. It is completed and tested in the laboratory. The results show that the sensitivity of the MNISBM meets the requirements of the measurement of near-infrared sky background level of several well-known astronomical infrared observing sites.
Design of a multiband near-infrared sky brightness monitor using an InSb detector
NASA Astrophysics Data System (ADS)
Dong, Shu-cheng; Wang, Jian; Tang, Qi-jie; Jiang, Feng-xin; Chen, Jin-ting; Zhang, Yi-hao; Wang, Zhi-yue; Chen, Jie; Zhang, Hong-fei; Jiang, Hai-jiao; Zhu, Qing-feng; Jiang, Peng; Ji, Tuo
2018-02-01
Infrared sky background level is an important parameter of infrared astronomy observations from the ground, particularly for a candidate site of an infrared capable observatory since low background level is required for such a site. The Chinese astronomical community is looking for a suitable site for a future 12 m telescope, which is designed for working in both optical and infrared wavelengths. However, none of the proposed sites has been tested for infrared observations. Nevertheless, infrared sky background measurements are also important during the design of infrared observing instruments. Based on the requirement, in order to supplement the current site survey data and guide the design of future infrared instruments, a multiband near-infrared sky brightness monitor (MNISBM) based on an InSb sensor is designed in this paper. The MNISBM consists of an optical system, mechanical structure and control system, detector and cooler, high gain readout electronics, and operational software. It is completed and tested in the laboratory. The results show that the sensitivity of the MNISBM meets the requirements of the measurement of near-infrared sky background level of several well-known astronomical infrared observing sites.
Measurements of airglow on Maunakea at Gemini Observatory
NASA Astrophysics Data System (ADS)
Roth, Katherine C.; Smith, Adam; Stephens, Andrew; Smirnova, Olesja
2016-07-01
Gemini Observatory on Maunakea has been collecting optical and infrared science data for almost 15 years. We have begun a program to analyze imaging data from two of the original facility instruments, GMOS and NIRI, in order to measure sky brightness levels in multiple infrared and optical broad-band filters. The present work includes data from mid-2016 back through late-2008. We present measured background levels as a function of several operational quantities (e.g. moon phase, hours from twilight, season). We find that airglow is a significant contributor to background levels in several filters. Gemini is primarily a queue scheduled telescope, with observations being optimally executed in order to provide the most efficient use of telescope time. We find that while most parameters are well-understood, the atmospheric airglow remains challenging to predict. This makes it difficult to schedule observations which require dark skies in these filters, and we suggest improvements to ensure data quality.
Measuring 226Ra/228Ra in Oceanic Lavas by MC-ICPMS
NASA Astrophysics Data System (ADS)
Standish, J. J.; Sims, K.; Ball, L.; Blusztajn, J.
2007-12-01
238U-230Th-226Ra disequilibrium in volcanic rocks provides an important and unique tool to evaluate timescales of recent magmatic processes. Determination of 230Th-226Ra disequilibria requires measurement of U and Th isotopes and concentrations as well as measurement of 226Ra. While measurement of U and Th by ICPMS is now well established, few published studies documenting 226Ra measurement via ICPMS exist. Using 228Ra as an isotope spike we have investigated two ion-counting methods; a 'peak-hopping' routine, where 226Ra and 228Ra are measured in sequence on the central discrete dynode ETP secondary electron multiplier (SEM), and simultaneous measurement of 226Ra and 228Ra on two multiple ion-counter system (MICS) channeltron type detectors mounted on the low end of the collector block. Here we present 226Ra measurement by isotope dilution using the Thermo Fisher NEPTUNE MC-ICPMS. Analysis of external rock standards TML and AThO along with mid-ocean ridge basalt (MORB) and ocean island basalt (OIB) samples show three issues that need to be considered when making precise and accurate Ra measurements: 1) mass bias, 2) background, and 3) relative efficiencies of the detectors when measuring in MICS mode. Due to the absence of an established 226Ra/228Ra standard, we have used U reference material NBL-112A to monitor mass bias. Although Ball et. al., (in press) have shown that U does not serve as an adequate proxy for Th (and thus not likely for Ra either), measurements of rock standards TML and AThO are repeatedly in equilibrium within the uncertainty of the measurements (where total uncertainty includes propagation of the uncertainty in the 226Ra standard used for calibrating the 228Ra spike). For this application, U is an adequate proxy for Ra mass bias at the 1% uncertainly level. The more important issue is the background correction. Because of the extensive chemistry required to separate and purify Ra (typically fg/g level in volcanic rocks), we observe large ambient backgrounds using both ion-counting techniques, which can significantly influence the measured 226Ra/228Ra ratio. Ra off-peak backgrounds need to be measured explicitly and quantitatively corrected. One advantage of using a 'peak-hopping' routine on the central SEM is the optional use of the high abundance sensitivity lens or repelling potential quadrapole (RPQ). This lens virtually eliminates the ambient background and significantly enhances the signal to noise ratio with only a small decrease in Ra ion transmission. Even with the diminished background levels observed using 'peak-hopping' on the SEM with the RPQ, accurate measurement of Ra isotopes requires off-peak background measurement. Finally, when using MICS it is important to account for the relative efficiency of the detectors. Multiple ion counting is, in principle, preferable to 'peak-hopping' because more time is spent counting each individual isotope. However, our results illustrate that proper calibration of detector yields requires dynamic switching of 226Ra between the two ion counters. This negates the inherent advantage of multiple ion counting. Therefore, when considering mass bias, background correction, and detector gain calibration, we conclude that 'peak-hopping' on the central SEM with the RPQ abundance filter is the preferred technique for 226Ra/228Ra isotopic measurement on the Neptune MC-ICPMS.
Public exposure due to external gamma background radiation in boundary areas of Iran.
Pooya, S M Hosseini; Dashtipour, M R; Enferadi, A; Orouji, T
2015-09-01
A monitoring program in boundary areas of a country is an appropriate way to indicate the level of public exposure. In this research, gamma background radiation was measured using TL dosimeters at 12 boundary areas as well as in the capital city of Iran during the period 2010 to 2011. The measurements were carried out in semi-annual time intervals from January to June and July to December in each year. The maximum average dose equivalent value measured was approximately 70 μSv/month for Tehran city. Also, the average dose values obtained were less than 40 μSv/month for all the cities located at the sea level except that of high level natural radiation area of Ramsar, and more than 55 μSv/month for the higher elevation cities. The public exposure due to ambient gamma dose equivalent in Iran is within the levels reported by UNSCEAR. Copyright © 2015 Elsevier Ltd. All rights reserved.
Radon as a Source of External Background at Homestake Mine
NASA Astrophysics Data System (ADS)
Thomas, Keenan; Mei, Dongming; Zhang, Chao; Gray, Fred; Gaitskell, Richard; Fiorucci, Simon
2009-05-01
External sources of radioactivity are important concerns for experiments planned for DUSEL at the Homestake Mine in Lead, South Dakota. Radon emanation and deposition is a major threat to the targeted sensitivity of low background experimentation such as double beta decay detection and dark matter searches. Methods to reduce and mitigate these measured levels will need to be developed to prevent experimental signals from contamination through airborne radon decays as well as the deposition of radon daughters. Radon levels were measured at various depths at the Homestake Mine in December of 2008, January and March of 2009. These measurements will be useful in the development of an underground ventilation system to dilute radon concentrations in the air and subsequent systems to provide radon-free air to clean rooms, as well as preparing researchers for the hazards they pose to their experiments. In addition, the measured radon level will be used to understand the radon emanation from different types of rock.
NASA Astrophysics Data System (ADS)
Mo, Xiao-Hu; Zhang, Jian-Yong; Zhang, Tian-Bao; Zhang, Qing-Jiang; Achasov, Mikhail; Fu, Cheng-Dong; Muchnoi, Nikolay; Qin, Qing; Qu, Hua-Min; Wang, Yi-Fang; Wu, Jing-Min; Xu, Jin-Qiang; Yu, Bo-Xiang
2009-10-01
The technique details for measuring radiation dose are expounded. The results of gamma and neutron radiation levels are presented and the corresponding radiation shielding is discussed based on the simplified estimation. In addition, the photon radiation level move as background for future experiments is measured by a NaI(Tl) detector.
Soudan Low Background Counting Facility (SOLO)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Attisha, Michael; Viveiros, Luiz de; Gaitksell, Richard
2005-09-08
The Soudan Low Background Counting Facility (SOLO) has been in operation at the Soudan Mine, MN since March 2003. In the past two years, we have gamma-screened samples for the Majorana, CDMS and XENON experiments. With individual sample exposure times of up to two weeks we have measured sample contamination down to the 0.1 ppb level for 238U / 232Th, and down to the 0.25 ppm level for 40K.
NASA Technical Reports Server (NTRS)
Sternfeld, H., Jr.; Hinterkeuser, E. G.; Hackman, R. B.; Davis, J.
1974-01-01
A study was conducted in which test subjects evaluated the sounds of a helicopter, a turbofan STOL and a turbojet airplane while engaged in work and leisure activities. Exposure to a high repetitive density of the aircraft sounds did not make the individual sounds more annoying but did create an unacceptable environment. The application of a time duration term to db(A) resulted in a measure which compared favorably with EPNL as a predictor of annoyance. Temporal variations in background noise level had no significant effect on the rated annoyance.
Pico-coulomb charge measured at BELLA to percent-level precision using a Turbo-ICT
NASA Astrophysics Data System (ADS)
Nakamura, K.; Mittelberger, D. E.; Gonsalves, A. J.; Daniels, J.; Mao, H.-S.; Stulle, F.; Bergoz, J.; Leemans, W. P.
2016-03-01
Precise diagnostics of picocoulomb level particle bunches produced by laser plasma accelerators (LPAs) can be a significant challenge. Without proper care, the small signals associated with such bunches can be dominated by a background generated by laser, target, laser-plasma interaction and particle induced radiation. In this paper, we report on first charge measurements using the newly developed Turbo-ICT for LPAs. We outline the Turbo-ICT working principle, which allows precise sub-picocoulomb measurements even in the presence of significant background signals. A comparison of the Turbo-ICT, a conventional integrating current transformer (ICT) and a scintillating screen (Lanex) was carried out at the Berkeley Lab Laser Accelerator. Results show that the Turbo-ICT can measure sub-picocoulomb charge accurately and has significantly improved noise immunity compared to the ICT.
Physiologic correlates to background noise acceptance
NASA Astrophysics Data System (ADS)
Tampas, Joanna; Harkrider, Ashley; Nabelek, Anna
2004-05-01
Acceptance of background noise can be evaluated by having listeners indicate the highest background noise level (BNL) they are willing to accept while following the words of a story presented at their most comfortable listening level (MCL). The difference between the selected MCL and BNL is termed the acceptable noise level (ANL). One of the consistent findings in previous studies of ANL is large intersubject variability in acceptance of background noise. This variability is not related to age, gender, hearing sensitivity, personality, type of background noise, or speech perception in noise performance. The purpose of the current experiment was to determine if individual differences in physiological activity measured from the peripheral and central auditory systems of young female adults with normal hearing can account for the variability observed in ANL. Correlations between ANL and various physiological responses, including spontaneous, click-evoked, and distortion-product otoacoustic emissions, auditory brainstem and middle latency evoked potentials, and electroencephalography will be presented. Results may increase understanding of the regions of the auditory system that contribute to individual noise acceptance.
Teachers' literacy-related knowledge and self-perceptions in relation to preparation and experience.
Spear-Swerling, Louise; Brucker, Pamela Owen; Alfano, Michael P
2005-12-01
After rating their own literacy-related knowledge in three areas (knowledge about reading/reading development, phonemic awareness/phonics, and morpheme awareness/structural analysis), graduate teacher-education students completed five tasks intended to measure their actual disciplinary knowledge in these areas. Teachers with high levels of prior background (i.e., course preparation and experience) rated themselves as significantly more knowledgeable than did low-background teachers in all areas; high-background participants also significantly outperformed low-background participants on all tasks. However, even high-background teachers scored well below ceiling on the tasks. Regression analyses indicated that teachers' self-perceptions and knowledge were positively influenced by both level of preparation and teaching experience, although the influences on teachers' knowledge differed by task. Teachers had some accurate perceptions of their own knowledge, especially in the area of phonics. Results suggest that differentiating levels of preparation may be useful in studying teacher knowledge, and also support the notion of a substantial gap between research on reading and teacher preparation in reading.
Ethnic heterogeneity, social capital and psychological distress in Sweden.
Johnson-Singh, Charisse M; Rostila, Mikael; Ponce de Leon, Antonio; Forsell, Yvonne; Engström, Karin
2018-05-25
Ethnic heterogeneity has been linked to both protective and detrimental effects on mental health. Few studies have investigated the role of social capital in this relationship and none have found that it has an explanatory role. The aim of this study is to investigate the relationship between two measures of ethnic heterogeneity and psychological distress in Stockholm County, as well as the explanatory role of social capital for individuals with Swedish-background, foreign-background and those who are foreign-born. This study used data collected from respondents aged 18-64 to the 2002, 2006, 2010 baseline questionnaires of the Stockholm Public Health Cohort and was linked with individual and area-level register information. Ethnic heterogeneity was the main exposure, measured by: 1) ethnic density, defined as the proportion of first and second generation immigrants with 2 foreign-born parents; and 2) ethnic diversity, using the fragmentation index. Social capital measures of individual and contextual-level social support and horizontal trust were the main explanatory factors of interest. The outcome, psychological distress, was assessed using the General Health Questionnaire-12 with a 2/3 cut-off. Prevalence ratios with 95% confidence intervals were estimated using multi-level poisson regression with robust variances. Age and sex adjusted analyses for the whole study population demonstrated that a 10% increase in ethnic density or diversity was associated with a 1.06 (1.05-1.07) times higher prevalence of psychological distress. In the stratified analyses, both foreign-born respondents and those with Swedish-background showed increasing prevalence of psychological distress with increasing ethnic heterogeneity. However, this trend was entirely explained by socioeconomic factors in the Swedish-background respondents and by additional adjustments for individual and contextual social support and horizontal trust for the foreign-born. Further adjustment for contextual horizontal trust showed ethnic heterogeneity to be protective for respondents Swedish-background. There was no clear trend between ethnic heterogeneity and psychological distress for respondents with foreign-background. The association between ethnic heterogeneity and psychological distress differs by ethnic background. There was no difference in this association based on the measure of ethnic heterogeneity used, nor in the explanatory role of social capital between ethnic heterogeneity measures. Socioeconomic indicators and some elements of individual and contextual social capital are important explanatory factors of the excess risk of psychological distress with regards to ethnic heterogeneity. Copyright © 2018 Elsevier Ltd. All rights reserved.
2014-01-01
Background The past five years has seen considerable expansion of wind power generation in Ontario, Canada. Most recently worries about exposure to electromagnetic fields (EMF) from wind turbines, and associated electrical transmission, has been raised at public meetings and legal proceedings. These fears have not been based on any actual measurements of EMF exposure surrounding existing projects but appear to follow from worries from internet sources and misunderstanding of the science. Methods The study was carried out at the Kingsbridge 1 Wind Farm located near Goderich, Ontario, Canada. Magnetic field measurements were collected in the proximity of 15 Vestas 1.8 MW wind turbines, two substations, various buried and overhead collector and transmission lines, and nearby homes. Data were collected during three operational scenarios to characterize potential EMF exposure: ‘high wind’ (generating power), ‘low wind’ (drawing power from the grid, but not generating power) and ‘shut off’ (neither drawing, nor generating power). Results Background levels of EMF (0.2 to 0.3 mG) were established by measuring magnetic fields around the wind turbines under the ‘shut off’ scenario. Magnetic field levels detected at the base of the turbines under both the ‘high wind’ and ‘low wind’ conditions were low (mean = 0.9 mG; n = 11) and rapidly diminished with distance, becoming indistinguishable from background within 2 m of the base. Magnetic fields measured 1 m above buried collector lines were also within background (≤ 0.3 mG). Beneath overhead 27.5 kV and 500 kV transmission lines, magnetic field levels of up to 16.5 and 46 mG, respectively, were recorded. These levels also diminished rapidly with distance. None of these sources appeared to influence magnetic field levels at nearby homes located as close as just over 500 m from turbines, where measurements immediately outside of the homes were ≤ 0.4 mG. Conclusions The results suggest that there is nothing unique to wind farms with respect to EMF exposure; in fact, magnetic field levels in the vicinity of wind turbines were lower than those produced by many common household electrical devices and were well below any existing regulatory guidelines with respect to human health. PMID:24529028
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mace, Emily; Aalseth, Craig; Alexander, Tom
Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the isotope’s respective energy spectra. This activity makes direct dual-isotope measurements challenging without additional chemistry to concentrate the tritium in a sample. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120 mg of H2O and present sensitivity results.
Handbook of aircraft noise metrics
NASA Technical Reports Server (NTRS)
Bennett, R. L.; Pearsons, K. S.
1981-01-01
Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.
Handbook of aircraft noise metrics
NASA Astrophysics Data System (ADS)
Bennett, R. L.; Pearsons, K. S.
1981-03-01
Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.
Stroke-model-based character extraction from gray-level document images.
Ye, X; Cheriet, M; Suen, C Y
2001-01-01
Global gray-level thresholding techniques such as Otsu's method, and local gray-level thresholding techniques such as edge-based segmentation or the adaptive thresholding method are powerful in extracting character objects from simple or slowly varying backgrounds. However, they are found to be insufficient when the backgrounds include sharply varying contours or fonts in different sizes. A stroke-model is proposed to depict the local features of character objects as double-edges in a predefined size. This model enables us to detect thin connected components selectively, while ignoring relatively large backgrounds that appear complex. Meanwhile, since the stroke width restriction is fully factored in, the proposed technique can be used to extract characters in predefined font sizes. To process large volumes of documents efficiently, a hybrid method is proposed for character extraction from various backgrounds. Using the measurement of class separability to differentiate images with simple backgrounds from those with complex backgrounds, the hybrid method can process documents with different backgrounds by applying the appropriate methods. Experiments on extracting handwriting from a check image, as well as machine-printed characters from scene images demonstrate the effectiveness of the proposed model.
Ultra Rapid Object Categorization: Effects of Level, Animacy and Context
Praß, Maren; Grimsen, Cathleen; König, Martina; Fahle, Manfred
2013-01-01
It is widely agreed that in object categorization bottom-up and top-down influences interact. How top-down processes affect categorization has been primarily investigated in isolation, with only one higher level process at a time being manipulated. Here, we investigate the combination of different top-down influences (by varying the level of category, the animacy and the background of the object) and their effect on rapid object categorization. Subjects participated in a two-alternative forced choice rapid categorization task, while we measured accuracy and reaction times. Subjects had to categorize objects on the superordinate, basic or subordinate level. Objects belonged to the category animal or vehicle and each object was presented on a gray, congruent (upright) or incongruent (inverted) background. The results show that each top-down manipulation impacts object categorization and that they interact strongly. The best categorization was achieved on the superordinate level, providing no advantage for basic level in rapid categorization. Categorization between vehicles was faster than between animals on the basic level and vice versa on the subordinate level. Objects in homogenous gray background (context) yielded better overall performance than objects embedded in complex scenes, an effect most prominent on the subordinate level. An inverted background had no negative effect on object categorization compared to upright scenes. These results show how different top-down manipulations, such as category level, category type and background information, are related. We discuss the implications of top-down interactions on the interpretation of categorization results. PMID:23840810
Ultra rapid object categorization: effects of level, animacy and context.
Praß, Maren; Grimsen, Cathleen; König, Martina; Fahle, Manfred
2013-01-01
It is widely agreed that in object categorization bottom-up and top-down influences interact. How top-down processes affect categorization has been primarily investigated in isolation, with only one higher level process at a time being manipulated. Here, we investigate the combination of different top-down influences (by varying the level of category, the animacy and the background of the object) and their effect on rapid object categorization. Subjects participated in a two-alternative forced choice rapid categorization task, while we measured accuracy and reaction times. Subjects had to categorize objects on the superordinate, basic or subordinate level. Objects belonged to the category animal or vehicle and each object was presented on a gray, congruent (upright) or incongruent (inverted) background. The results show that each top-down manipulation impacts object categorization and that they interact strongly. The best categorization was achieved on the superordinate level, providing no advantage for basic level in rapid categorization. Categorization between vehicles was faster than between animals on the basic level and vice versa on the subordinate level. Objects in homogenous gray background (context) yielded better overall performance than objects embedded in complex scenes, an effect most prominent on the subordinate level. An inverted background had no negative effect on object categorization compared to upright scenes. These results show how different top-down manipulations, such as category level, category type and background information, are related. We discuss the implications of top-down interactions on the interpretation of categorization results.
NASA Astrophysics Data System (ADS)
Joglekar, Prasad; Shastry, Karthik; Hulbert, Steven; Weiss, Alex
2014-03-01
Auger Photoelectron Coincidence Spectroscopy (APECS), in which the Auger spectra is measured in coincidence with the core level photoelectron, is capable of pulling difficult to observe low energy Auger peaks out of a large background due mostly to inelastically scattered valence band photoelectrons. However the APECS method alone cannot eliminate the background due to valence band VB photoemission processes in which the initial photon energy is shared by 2 or more electrons and one of the electrons is in the energy range of the core level photoemission peak. Here we describe an experimental method for estimating the contributions from these background processes in the case of an Ag N23VV Auger spectra obtained in coincidence with the 4p photoemission peak. A beam of 180eV photons was incident on a Ag sample and a series of coincidence measurements were made with one cylindrical mirror analyzer (CMA) set at a fixed energies between the core and the valence band and the other CMA scanned over a range corresponding to electrons leaving the surface between 0eV and the 70eV. The spectra obtained were then used to obtain an estimate of the background in the APECS spectra due to multi-electron and inelastic VB photoemission processes. NSF, Welch Foundation.
NASA Technical Reports Server (NTRS)
De Amici, Giovanni; Limon, Michele; Smoot, George F.; Bersanelli, Marco; Kogut, AL; Levin, Steve
1991-01-01
As part of an international collaboration to measure the low-frequency spectrum of the cosmic microwave background (CMB) radiation, its temperature was measured at a frequency of 3.8 GHz, during the austral spring of 1989, obtaining a brightness temperature, T(CMB), of 2.64 +/-0.07 K (68 percent confidence level). The new result is in agreement with previous measurements at the same frequency obtained in 1986-88 from a very different site and has comparable error bars. Combining measurements from all years, T(CMB) = 2.64 +/-0.06 K is obtained.
2014-01-01
Background The UK Clinical Aptitude Test (UKCAT) was introduced to facilitate widening participation in medical and dental education in the UK by providing universities with a continuous variable to aid selection; one that might be less sensitive to the sociodemographic background of candidates compared to traditional measures of educational attainment. Initial research suggested that males, candidates from more advantaged socioeconomic backgrounds and those who attended independent or grammar schools performed better on the test. The introduction of the A* grade at A level permits more detailed analysis of the relationship between UKCAT scores, secondary educational attainment and sociodemographic variables. Thus, our aim was to further assess whether the UKCAT is likely to add incremental value over A level (predicted or actual) attainment in the selection process. Methods Data relating to UKCAT and A level performance from 8,180 candidates applying to medicine in 2009 who had complete information relating to six key sociodemographic variables were analysed. A series of regression analyses were conducted in order to evaluate the ability of sociodemographic status to predict performance on two outcome measures: A level ‘best of three’ tariff score; and the UKCAT scores. Results In this sample A level attainment was independently and positively predicted by four sociodemographic variables (independent/grammar schooling, White ethnicity, age and professional social class background). These variables also independently and positively predicted UKCAT scores. There was a suggestion that UKCAT scores were less sensitive to educational background compared to A level attainment. In contrast to A level attainment, UKCAT score was independently and positively predicted by having English as a first language and male sex. Conclusions Our findings are consistent with a previous report; most of the sociodemographic factors that predict A level attainment also predict UKCAT performance. However, compared to A levels, males and those speaking English as a first language perform better on UKCAT. Our findings suggest that UKCAT scores may be more influenced by sex and less sensitive to school type compared to A levels. These factors must be considered by institutions utilising the UKCAT as a component of the medical and dental school selection process. PMID:24400861
Lindsay Light Radiological Survey 160 N Columbus Drive Lower Level, March 2013
The background radiation levels in the area were recorded being between 3,000 and 3,500 cpm. Radiation levels at the surface of soil in the approximately 60 square-feet area interest were measured between 3,000 and 4,000 cpm.
Effect of room absorption on human vocal output in multitalker situations.
Nijs, Lau; Saher, Konca; den Ouden, Daniël
2008-02-01
People increase their vocal output in noisy environments. This is known as the Lombard effect. The aim of the present study was to measure the effect as a function of the absorption coefficient. The noise source was generated by using other talkers in the room. A-weighted sound levels were measured in a 108 m(3) test room. The number of talkers varied from one to four and the absorption coefficients from 0.12 to 0.64. A model was introduced based on the logarithmic sum of the level found in an anechoic room plus the increasing portion of noise levels up to 80 dB. Results show that the model fits the measurements when a maximum slope of 0.5 dB per 1.0 dB increase in background level is used. Hence Lombard slopes vary from 0.2 dBdB at 50 dB background level to 0.5 dBdB at 80 dB. In addition, both measurements and the model predict a decrease of 5.5 dB per doubling of absorbing area in a room when the number of talkers is constant. Sound pressure levels increase for a doubling of talkers from 3 dB for low densities to 6 dB for dense crowds. Finally, there was correspondence between the model estimation and previous measurements reported in the literature.
Measurement of the cosmic microwave background spectrum by the COBE FIRAS instrument
NASA Technical Reports Server (NTRS)
Mather, J. C.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Fixsen, D. J.; Hewagama, T.; Isaacman, R. B.; Jensen, K. A.; Meyer, S. S.; Noerdlinger, P. D.
1994-01-01
The cosmic microwave background radiation (CMBR) has a blackbody spectrum within 3.4 x 10(exp -8) ergs/sq cm/s/sr cm over the frequency range from 2 to 20/cm (5-0.5 mm). These measurements, derived from the Far-Infrared Absolute Spectrophotomer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite, imply stringent limits on energy release in the early universe after t approximately 1 year and redshift z approximately 3 x 10(exp 6). The deviations are less than 0.30% of the peak brightness, with an rms value of 0.01%, and the dimensionless cosmological distortion parameters are limited to the absolute value of y is less than 2.5 x 10(exp -5) and the absolute value of mu is less than 3.3 x 10(exp -4) (95% confidence level). The temperature of the CMBR is 2.726 +/- 0.010 K (95% confidence level systematic).
Development of an Ultra-Low Background Liquid Scintillation Counter for Trace Level Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erchinger, Jennifer L.; Orrell, John L.; Aalseth, Craig E.
2015-09-01
Low-level liquid scintillation counting (LSC) has been established as one of the radiation detection techniques useful in elucidating environmental processes and environmental monitoring around nuclear facilities. The Ultra-Low Background Liquid Scintillation Counter (ULB-LSC) under construction in the Shallow Underground Laboratory at Pacific Northwest National Laboratory aims to further reduce the MDAs and/or required sample processing. Through layers of passive shielding in conjunction with an active veto and 30 meters water equivalent overburden, the background reduction is expected to be 10 to 100 times below typical analytic low-background liquid scintillation systems. Simulations have shown an expected background of around 14 countsmore » per day. A novel approach to the light collection will use a coated hollow light guide cut into the inner copper shielding. Demonstration LSC measurements will show low-energy detection, spectral deconvolution, and alpha/beta discrimination capabilities, from trials with standards of tritium, strontium-90, and actinium-227, respectively. An overview of the system design and expected demonstration measurements will emphasize the potential applications of the ULB-LSC in environmental monitoring for treaty verification, reach-back sample analysis, and facility inspections.« less
Measurements of SWIR backgrounds using the swux unit of measure
NASA Astrophysics Data System (ADS)
Richards, A.; Hübner, M.; Vollmer, M.
2018-04-01
The SWIR waveband between 0.8μm-1.8μm is getting increasingly exploited by imaging systems in a variety of different applications, including persistent imaging for security and surveillance of high-value assets, handheld tactical imagers, range-gated imaging systems and imaging LADAR for driverless vehicles. The vast majority of these applications utilize lattice-matched InGaAs detectors in their imaging sensors, and these sensors are rapidly falling in price, leading to their widening adoption. As these sensors are used in novel applications and locations, it is important that ambient SWIR backgrounds be understood and characterized for a variety of different field conditions, primarily for the purposes of system performance modeling of SNR and range metrics. SWIR irradiance backgrounds do not consistently track visible-light illumination at all. There is currently little of this type of information in the open literature, particularly measurements of SWIR backgrounds in urban areas, natural areas, or indoors. This paper presents field measurements done with an InGaAs detector calibrated in the swux unit of InGaAs-band-specific irradiance proposed by two of the authors in 2017. Simultaneous measurements of illuminance levels (in lux) at these sites are presented, as well as visible and InGaAs camera images of the scenery at some of these measurement sites. The swux and lux measurement hardware is described, along with the methods used to calibrate it. Finally, the swux levels during the partial and total phases of the total solar eclipse of 2017 are presented, along with curves fitted to the data from a theoretical model, based on obscuration of the sun by the moon. The apparent differences between photometric and swux measurements will be discussed.
Analysis of selected volatile organic compounds at background level in South Africa.
NASA Astrophysics Data System (ADS)
Ntsasa, Napo; Tshilongo, James; Lekoto, Goitsemang
2017-04-01
Volatile organic compounds (VOC) are measured globally at urban air pollution monitoring and background level at specific locations such as the Cape Point station. The urban pollution monitoring is legislated at government level; however, the background levels are scientific outputs of the World Meteorological Organisation Global Atmospheric Watch program (WMO/GAW). The Cape Point is a key station in the Southern Hemisphere which monitors greenhouse gases and halocarbons, with reported for over the past decade. The Cape Point station does not have the measurement capability VOC's currently. A joint research between the Cape Point station and the National Metrology Institute of South Africa (NMISA) objective is to perform qualitative and quantitative analysis of volatile organic compounds listed in the GAW program. NMISA is responsible for development, maintain and disseminate primary reference gas mixtures which are directly traceable to the International System of Units (SI) The results of some volatile organic compounds which where sampled in high pressure gas cylinders will be presented. The analysis of samples was performed on the gas chromatography with flame ionisation detector and mass selective detector (GC-FID/MSD) with a dedicate cryogenic pre-concentrator system. Keywords: volatile organic compounds, gas chromatography, pre-concentrator
Glucose concentration measured by the hybrid coherent anti-Stokes Raman-scattering technique
NASA Astrophysics Data System (ADS)
Wang, Xi; Zhang, Aihua; Zhi, Miaochan; Sokolov, Alexei V.; Welch, George R.
2010-01-01
We investigate the possibility of using a hybrid coherent anti-Stokes Raman scattering technique for noninvasive monitoring of blood glucose levels. Our technique combines instantaneous coherent excitation of several characteristic molecular vibrations with subsequent probing of these vibrations by an optimally shaped, time-delayed, narrowband laser pulse. This pulse configuration mitigates the nonresonant four-wave mixing background while maximizing the Raman-resonant signal and allows rapid and highly specific detection even in the presence of multiple scattering. Under certain conditions we find that the measured signal is linearly proportional to the glucose concentration due to optical interference with the residual background light, which allows reliable detection of spectral signatures down to medically relevant glucose levels.
Background noise levels measured in the NASA Lewis 9- by 15-foot low-speed wind tunnel
NASA Technical Reports Server (NTRS)
Woodward, Richard P.; Dittmar, James H.; Hall, David G.; Kee-Bowling, Bonnie
1994-01-01
The acoustic capability of the NASA Lewis 9 by 15 Foot Low Speed Wind Tunnel has been significantly improved by reducing the background noise levels measured by in-flow microphones. This was accomplished by incorporating streamlined microphone holders having a profile developed by researchers at the NASA Ames Research Center. These new holders were fabricated for fixed mounting on the tunnel wall and for an axially traversing microphone probe which was mounted to the tunnel floor. Measured in-flow noise levels in the tunnel test section were reduced by about 10 dB with the new microphone holders compared with those measured with the older, less refined microphone holders. Wake interference patterns between fixed wall microphones were measured and resulted in preferred placement patterns for these microphones to minimize these effects. Acoustic data from a model turbofan operating in the tunnel test section showed that results for the fixed and translating microphones were equivalent for common azimuthal angles, suggesting that the translating microphone probe, with its significantly greater angular resolution, is preferred for sideline noise measurements. Fixed microphones can provide a local check on the traversing microphone data quality, and record acoustic performance at other azimuthal angles.
Teaching about Natural Background Radiation
ERIC Educational Resources Information Center
Al-Azmi, Darwish; Karunakara, N.; Mustapha, Amidu O.
2013-01-01
Ambient gamma dose rates in air were measured at different locations (indoors and outdoors) to demonstrate the ubiquitous nature of natural background radiation in the environment and to show that levels vary from one location to another, depending on the underlying geology. The effect of a lead shield on a gamma radiation field was also…
Regional background levels of exposure to fish from petroleum and combustion by-products were determined for the state of Ohio and the mid-Atlantic region. Exposures were measured using bile metabolites that fluoresce at 290/335 nm for naphthalene(NAPH)-type compounds and at 380...
ERIC Educational Resources Information Center
Day, Sophia E.; Hinterland, Kinjia; Myers, Christa; Gupta, Leena; Harris, Tiffany G.; Konty, Kevin J.
2016-01-01
Background: Socioeconomic status (SES) impacts health outcomes. The Youth Risk Behavior Survey (YRBS), like many school-based data sources, lacks individual-level poverty information. We propose using school-level percentages of student eligibility for free/reduced-price meals (%FRPM) as a proxy for individual-level poverty. Methods: Using the New…
ERIC Educational Resources Information Center
Finlayson, Janet; Turner, Angela; Granat, Malcolm H.
2011-01-01
Background: Lack of regular physical activity is a significant risk to health. The aim of this study was to objectively measure the levels and patterns of activity of adults with intellectual disabilities, to inform the design of studies aimed at increasing activity and health in this population. Materials and Methods: Interviews were conducted…
MEASURING NEUTRON STAR RADII VIA PULSE PROFILE MODELING WITH NICER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Özel, Feryal; Psaltis, Dimitrios; Bauböck, Michi
2016-11-20
The Neutron-star Interior Composition Explorer is an X-ray astrophysics payload that will be placed on the International Space Station . Its primary science goal is to measure with high accuracy the pulse profiles that arise from the non-uniform thermal surface emission of rotation-powered pulsars. Modeling general relativistic effects on the profiles will lead to measuring the radii of these neutron stars and to constraining their equation of state. Achieving this goal will depend, among other things, on accurate knowledge of the source, sky, and instrument backgrounds. We use here simple analytic estimates to quantify the level at which these backgroundsmore » need to be known in order for the upcoming measurements to provide significant constraints on the properties of neutron stars. We show that, even in the minimal-information scenario, knowledge of the background at a few percent level for a background-to-source countrate ratio of 0.2 allows for a measurement of the neutron star compactness to better than 10% uncertainty for most of the parameter space. These constraints improve further when more realistic assumptions are made about the neutron star emission and spin, and when additional information about the source itself, such as its mass or distance, are incorporated.« less
Search for Linear Polarization of the Cosmic Background Radiation
DOE R&D Accomplishments Database
Lubin, P. M.; Smoot, G. F.
1978-10-01
We present preliminary measurements of the linear polarization of the cosmic microwave background (3 deg K blackbody) radiation. These ground-based measurements are made at 9 mm wavelength. We find no evidence for linear polarization, and set an upper limit for a polarized component of 0.8 m deg K with a 95% confidence level. This implies that the present rate of expansion of the Universe is isotropic to one part in 10{sup 6}, assuming no re-ionization of the primordial plasma after recombination
Parks, David R.; Khettabi, Faysal El; Chase, Eric; Hoffman, Robert A.; Perfetto, Stephen P.; Spidlen, Josef; Wood, James C.S.; Moore, Wayne A.; Brinkman, Ryan R.
2017-01-01
We developed a fully automated procedure for analyzing data from LED pulses and multi-level bead sets to evaluate backgrounds and photoelectron scales of cytometer fluorescence channels. The method improves on previous formulations by fitting a full quadratic model with appropriate weighting and by providing standard errors and peak residuals as well as the fitted parameters themselves. Here we describe the details of the methods and procedures involved and present a set of illustrations and test cases that demonstrate the consistency and reliability of the results. The automated analysis and fitting procedure is generally quite successful in providing good estimates of the Spe (statistical photoelectron) scales and backgrounds for all of the fluorescence channels on instruments with good linearity. The precision of the results obtained from LED data is almost always better than for multi-level bead data, but the bead procedure is easy to carry out and provides results good enough for most purposes. Including standard errors on the fitted parameters is important for understanding the uncertainty in the values of interest. The weighted residuals give information about how well the data fits the model, and particularly high residuals indicate bad data points. Known photoelectron scales and measurement channel backgrounds make it possible to estimate the precision of measurements at different signal levels and the effects of compensated spectral overlap on measurement quality. Combining this information with measurements of standard samples carrying dyes of biological interest, we can make accurate comparisons of dye sensitivity among different instruments. Our method is freely available through the R/Bioconductor package flowQB. PMID:28160404
Performance of charge-injection-device infrared detector arrays at low and moderate backgrounds
NASA Technical Reports Server (NTRS)
Mckelvey, M. E.; Mccreight, C. R.; Goebel, J. H.; Reeves, A. A.
1985-01-01
Three 2 x 64 element charge injection device infrared detector arrays were tested at low and moderate background to evaluate their usefulness for space based astronomical observations. Testing was conducted both in the laboratory and in ground based telescope observations. The devices showed an average readout noise level below 200 equivalent electrons, a peak responsivity of 4 A/W, and a noise equivalent power of 3x10 sq root of W/Hz. Array well capacity was measured to be significantly smaller than predicted. The measured sensitivity, which compares well with that of nonintegrating discrete extrinsic silicon photoconductors, shows these arrays to be useful for certain astronomical observations. However, the measured readout efficiency and frequency response represent serious limitations in low background applications.
Wang, Ying; Li, Ling-Jun; Liu, Yang
2012-11-01
The interannual variability of NO2 levels in two major Chinese economic regions, the Beijing-Tianjin-Hebei (BTH) economic circle and the Yangtze River Delta (YRD), were studied using multiple years of OMI-retrieved NO2 columns and ground measurements. The NO2 columns were comparable in the two regions, which were - 50% higher than the BTH and YRD regional background and two times higher than the Asia-Europe continental background. Satellite data showed that the high NO2 regions scattered around Beijing and Shanghai in summer, and the coverage of high NO2 regions increased in spring and merged in winter, affecting the entire eastern China. Ground level NO2 concentrations in the urban centers of Beijing and Shanghai were also comparable, which were - 10 times greater than the regional background and 1 000 times higher than the Asia-Europe continental background. As industries gradually migrated out of the urban centers, the NO2 concentrations in Beijing and Shanghai decreased, but the regional background NO2 concentration in BTH and YRD increased. It reflected in part the impact of NO2 emission reductions related to fossil fuel combustion as a result of air quality control measures in BTH and YRD. NO2 levels during the Beijing 2008 Olympic Games and the Shanghai World Expo 2010 decreased temporarily, but bounced back quickly afterwards, indicating that sustainable air quality improvement can only be achieved through long-term regional efforts.
NASA Astrophysics Data System (ADS)
Webster, C. R.; Mahaffy, P. R.; Atreya, S. K.
2016-12-01
In situ measurements of atmospheric methane have been made over a 3-year period at Gale Crater on Mars using the Tunable Laser Spectrometer (TLS) instrument in the Sample Analysis at Mars (SAM) suite on the Curiosity rover. We have reported two important observations: (i) a background level of 0.5 ppbv that is about five times lower than some model predictions based on generation from UV degradation of micro-meteorites or interplanetary dust delivered to the martian surface; (ii) a "spike" of elevated levels of 7 ppbv that were seen1 on four sequential observations over a 2-month period before dropping to background levels. This spike was attributed to an episodic release from a small local source, probably to the north of Gale crater. While the elevated levels of the spike did not return (repeat) one Mars year later, we have seen what appears to be a seasonal variation to the background levels that are all < 1ppbv. The variation ranges from a low of 0.2 ppbv in the northern hemisphere spring to 0.9 ppbv in the northern hemisphere late summer, a change in mixing ratio over a range larger than expected from our current understanding of methane sources and sinks. We will present recent atmospheric methane measurements, and their correlations with a variety of environmental conditions at the location of Curiosity, and discuss the mechanisms that are believed to be contributing to the low background methane signals and their variation. 1 "Mars Methane Detection and Variability at Gale Crater", C. R. Webster et al., Science, 347, 415-417 (2015) and references therein. The research described here was carried out in part at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (NASA).
Further comparison of MODTRAN 5 to measured data in the UV band
NASA Astrophysics Data System (ADS)
Smith, Leon; Richardson, Mark; Ayling, Richard; Barlow, Nick
2014-10-01
The ability to accurately model background radiation from the sun is important in understanding the operation of missile systems with ultraviolet (UV) guard channels. In theory a missile system's UV channel detects a target's silhouette, caused by its `negative contrast' with respect to background UV radiation. The variation in background levels of UV will therefore have an effect on the operability of a missile system that utilises a UV channel. In this paper an update on the measurement and comparison of background UV-A radiation to data produced by Moderate Resolution Atmospheric Transmission 5 (MODTRAN®5) is given. In the past surface flux and radiance data calculated using MODTRAN®5 has been compared to data from the World Ozone and Ultraviolet Data Centre (WOUDC) archive, and measurements taken by the author at the Defence Academy of the UK. With the aid of spectral measurement equipment, new measurements have been made and compared with the radiance profiles produced by MODTRAN®5, including measurements made throughout both winter and summer months. Also discussed are the effects of scattering and absorption by different cloud types on the amount of radiation observed at the Earth's surface.
GRC-11-02-17-WindTunnel-9x15-001
2017-11-02
The Aerosciences Evaluation and Test Capabilities (AETC) Portfolio implemented the Capability Challenge to “Reduce Background Noise Levels for Engine Efficiency Measurements at the NASA Glenn 9x15 Low Speed Wind Tunnel”. The 9x15 Low Speed Wind Tunnel Acoustic Improvements animation documents the acoustic modifications being made to the 9x15 leg of the wind tunnel to reduce background noise levels. A brief history of the 9x15, research testing performed in the wind tunnel, the need to reduce background noise, and the five state of the art acoustic design modifications are documented in the animation. The expected noise reduction is presented audibly and the resulting benefit to NASA is also defined.
Suppression of background noise in a transonic wind-tunnel test section
NASA Technical Reports Server (NTRS)
Schutzenhofer, L. A.; Howard, P. W.
1975-01-01
Some exploratory tests were recently performed in the transonic test section of the NASA Marshall Space Flight Center 14-in. wind tunnel to suppress the background noise. In these tests, the perforated walls of the test section were covered with fine wire screens. The screens eliminated the edge tones generated by the holes in the perforated walls and significantly reduced the tunnel background noise. The tunnel noise levels were reduced to such a degree by this simple modification at Mach numbers 0.75, 0.9, 1.1, 1.2, and 1.46 that the fluctuating pressure levels of a turbulent boundary layer could be measured on a 5-deg half-angle cone.
A measurement of the cosmic microwave background temperature at 7.5 GHz
NASA Technical Reports Server (NTRS)
Levin, S.; Bensadoun, M.; Bersanelli, M.; De Amici, G.; Kogut, A.; Limon, M.; Smoot, G.
1992-01-01
The temperature of the cosmic microwave background (CMB) radiation at a frequency of 7.5 GHz (4 cm wavelength) is measured, obtaining a brightness temperature of T(CMB) = 2.70 +/- 0.08 K (68 percent confidence level). The measurement was made from a site near the geographical South Pole during the austral spring of 1989 and was part of an international collaboration to measure the CMB spectrum at low frequencies with a variety of radiometers from several different sites. This recent result is in agreement with the 1988 measurement at the same frequency, which was made from a different site with significantly different systematic errors. The combined result of the 1988 and 1989 measurements is 2.64 +/- 0.06 K.
McCallum, Lindsay C; Whitfield Aslund, Melissa L; Knopper, Loren D; Ferguson, Glenn M; Ollson, Christopher A
2014-02-15
The past five years has seen considerable expansion of wind power generation in Ontario, Canada. Most recently worries about exposure to electromagnetic fields (EMF) from wind turbines, and associated electrical transmission, has been raised at public meetings and legal proceedings. These fears have not been based on any actual measurements of EMF exposure surrounding existing projects but appear to follow from worries from internet sources and misunderstanding of the science. The study was carried out at the Kingsbridge 1 Wind Farm located near Goderich, Ontario, Canada. Magnetic field measurements were collected in the proximity of 15 Vestas 1.8 MW wind turbines, two substations, various buried and overhead collector and transmission lines, and nearby homes. Data were collected during three operational scenarios to characterize potential EMF exposure: 'high wind' (generating power), 'low wind' (drawing power from the grid, but not generating power) and 'shut off' (neither drawing, nor generating power). Background levels of EMF (0.2 to 0.3 mG) were established by measuring magnetic fields around the wind turbines under the 'shut off' scenario. Magnetic field levels detected at the base of the turbines under both the 'high wind' and 'low wind' conditions were low (mean = 0.9 mG; n = 11) and rapidly diminished with distance, becoming indistinguishable from background within 2 m of the base. Magnetic fields measured 1 m above buried collector lines were also within background (≤ 0.3 mG). Beneath overhead 27.5 kV and 500 kV transmission lines, magnetic field levels of up to 16.5 and 46 mG, respectively, were recorded. These levels also diminished rapidly with distance. None of these sources appeared to influence magnetic field levels at nearby homes located as close as just over 500 m from turbines, where measurements immediately outside of the homes were ≤ 0.4 mG. The results suggest that there is nothing unique to wind farms with respect to EMF exposure; in fact, magnetic field levels in the vicinity of wind turbines were lower than those produced by many common household electrical devices and were well below any existing regulatory guidelines with respect to human health.
49 CFR 227.109 - Audiometric testing program.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Measurements of background sound pressure levels in the audiometric test room as required in appendix D of this... occupational noise in excess of the action level. Hearing protectors may be used as a substitute for the... railroad shall notify its employees of the need to avoid high levels of non-occupational noise exposure...
California Baseline Ozone Transport Study (CABOTS): Ozonesonde Measurements
NASA Astrophysics Data System (ADS)
Eiserloh, A. J., Jr.; Chiao, S.; Spitze, J.; Cauley, S.; Clark, J.; Roberts, M.
2016-12-01
Because the EPA recently lowered the ambient air quality standard for the 8-hr average of ozone (O3) to70 ppbv, California must continue to achieve significant reductions in ozone precursor emissions and prepare for new State Implementation Plans (SIP) to demonstrate how ground-level ambient ozone will be reduced below the new health-based standard. Prior studies suggest that background levels of ozone traveling across the Pacific Ocean can significantly influence surface ozone throughout California, particularly during the spring. Evidence has been presented indicating that background levels of ozone continue to increase in the western United States over the recent few decades, implying more ozone exceedances in the future. To better understand the contributions of the external natural and anthropogenic pollution sources as well as atmospheric processes for surface ozone concentrations in California during the spring and summer months, the California Baseline Ozone Transport Study (CABOTS) has been established. One major goal of CABOTS is to implement near daily ozonesonde measurements along the California Coast to quantify background ozone aloft before entering the State during high ozone season. CABOTS has been ongoing from May through August of 2016 launching ozonesondes from Bodega Bay and Half Moon Bay, California. The temporal progression of ozonesonde measurements and subsequent analysis of the data will be discussed with a focus on the contribution of background ozone to surface ozone sites inland as well as likely origins of layers aloft. Comparisons of current ozonesondes versus prior ozonesonde studies of California will also be performed. A few selected cases of high ozone layers moving onshore from different sources will be discussed as well.
Gravitoinertial force level influences arm movement control
NASA Technical Reports Server (NTRS)
Fisk, J.; Lackner, J. R.; DiZio, P.
1993-01-01
1. The ability to move the forearm between remembered elbow joint angles immediately after rapid increases or decreases of the background gravitoinertial force (G) level was measured. The movements had been well-practiced in a normal 1G environment before the measurements in high-(1.8G) and low-force (0G) environments. The forearm and upper arm were always unsupported to maximize the influence of altered G-loading and to minimize extraneous cues about arm position. 2. Horizontal and vertical movement planes were studied to measure the effects of varying the G load in the movement plane within a given G background. Rapid and slow movements were studied to assess the role of proprioceptive feedback. 3. G level did not affect the amplitude of rapid movements, indicating that subjects were able to plan and to generate appropriate motor commands for the new G loading of the arm. The amplitude of slow movements was affected by G level, indicating that proprioceptive feedback is influenced by G level. 4. The effects of G level were similar for horizontal and vertical movements, indicating that proprioceptive information from supporting structures, such as the shoulder joint and muscles, had a role in allowing generation of the appropriate motor commands. 5. The incidence and size of dynamic overshoots were greater in 0G and for rapid movements. This G-related change in damping suggests a decrease in muscle spindle activity in 0G. A decrease in muscle spindle activity in 0G and an increase in 1.8G are consistent with the results of our prior studies on the tonic vibration reflex, locomotion, and perception of head movement trajectory in varying force backgrounds.
49 CFR 227.121 - Recordkeeping.
Code of Federal Regulations, 2010 CFR
2010-10-01
... exposure measurement records for specific locations available to regional or national labor representatives... ceases to do business, it shall transfer to the successor employer all records required to be maintained... measurements of the background sound pressure levels in audiometric test rooms; (vi) The model and serial...
Anisotropies in the diffuse gamma-ray background measured by the Fermi LAT
Ackermann, M.; Ajello, M.; Albert, A.; ...
2012-04-23
The contribution of unresolved sources to the diffuse gamma-ray background could induce anisotropies in this emission on small angular scales. Here, we analyze the angular power spectrum of the diffuse emission measured by the Fermi Large Area Telescope at Galactic latitudes | b | > 30 ° in four energy bins spanning 1–50 GeV. At multipoles ℓ ≥ 155 , corresponding to angular scales ≲ 2 ° , angular power above the photon noise level is detected at > 99.99 % confidence level in the 1–2 GeV, 2–5 GeV, and 5–10 GeV energy bins, and at > 99 % confidencemore » level at 10–50 GeV. Within each energy bin the measured angular power takes approximately the same value at all multipoles ℓ ≥ 155 , suggesting that it originates from the contribution of one or more unclustered source populations. Furthermore, the amplitude of the angular power normalized to the mean intensity in each energy bin is consistent with a constant value at all energies, C P / < I > 2 = 9.05 ± 0.84 × 10 - 6 sr , while the energy dependence of C P is consistent with the anisotropy arising from one or more source populations with power-law photon spectra with spectral index Γ s = 2.40 ± 0.07 . We also discuss the implications of the measured angular power for gamma-ray source populations that may provide a contribution to the diffuse gamma-ray background.« less
Particle and Smoke Detection on ISS for Next Generation Smoke Detectors
NASA Technical Reports Server (NTRS)
Urban, David L.; Ruff, Gary; Yuan, Zeng-guang; Sheredy, William; Funk, Greg
2007-01-01
Rapid fire detection requires the ability to differentiate fire signatures from background conditions and nuisance sources. Proper design of a fire detector requires detailed knowledge of all of these signal sources so that a discriminating detector can be designed. Owing to the absence of microgravity smoke data, all current spacecraft smoke detectors were designed based upon normal-g conditions. The removal of buoyancy reduces the velocities in the high temperature zones in flames, increasing the residence time of smoke particles and consequently allowing longer growth time for the particles. Recent space shuttle experiments confirmed that, in some cases, increased particles sizes are seen in low-gravity and that the relative performance of the ISS (International Space Station) and space-shuttle smoke-detectors changes in low-gravity; however, sufficient particle size information to design new detectors was not obtained. To address this issue, the SAME (Smoke Aerosol Measurement Experiment) experiment is manifested to fly on the ISS in 2007. The SAME experiment will make measurements of the particle size distribution of the smoke particulate from several typical spacecraft materials providing quantitative design data for spacecraft smoke detectors. A precursor experiment (DAFT: Dust Aerosol measurement Feasibility Test) flew recently on the ISS and provided the first measurement of the background smoke particulate levels on the ISS. These background levels are critical to the design of future smoke detectors. The ISS cabin was found to be a very clean environment with particulate levels substantially below the space shuttle and typical ground-based environments.
Casey, D T; Frenje, J A; Séguin, F H; Li, C K; Rosenberg, M J; Rinderknecht, H; Manuel, M J-E; Gatu Johnson, M; Schaeffer, J C; Frankel, R; Sinenian, N; Childs, R A; Petrasso, R D; Glebov, V Yu; Sangster, T C; Burke, M; Roberts, S
2011-07-01
A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.
Low stimulus environments: reducing noise levels in continuing care.
Brown, Juliette; Fawzi, Waleed; Shah, Amar; Joyce, Margaret; Holt, Genevieve; McCarthy, Cathy; Stevenson, Carmel; Marange, Rosca; Shakes, Joy; Solomon-Ayeh, Kwesi
2016-01-01
In the low stimulus environment project, we aimed to reduce the levels of intrusive background noise on an older adult mental health ward, combining a very straightforward measure on decibel levels with a downstream measure of reduced distress and agitation as expressed in incidents of violence. This project on reducing background noise levels on older adult wards stemmed from work the team had done on reducing levels of violence and aggression. We approached the problem using quality improvement methods. Reducing harm to patients and staff is a strategic aim of our Trust and in our efforts we were supported by the Trust's extensive programme of quality improvement, including training and support provided by the Institute for Healthcare Improvement and the trust's own Quality Improvement team. Prior to the project we were running a weekly multi-disciplinary quality improvement group on the ward. We established from this a sub-group to address the specific problem of noise levels and invited carers of people with dementia on our ward to the group. The project was led by nursing staff. We used a noise meter app readily downloadable from the internet to monitor background noise levels on the ward and establish a baseline measure. As a group we used a driver diagram to identify an overall aim and a clear understanding of the major factors that would drive improvements. We also used a staff and carer survey to identify further areas to work on. Change ideas that came from staff and carers included the use of the noise meter to track and report back on noise levels, the use of posters to remind staff about noise levels, the introduction of a visual indication of current noise levels (the Yacker Tracker), the addition of relaxing background music, and adaptations to furniture and environment. We tested many of these over the course of nine months in 2015, using the iterative learning gained from multiple PDSA cycles. The specific aim was a decrease from above 60dB to below 50dB in background noise on the wards. Following our interventions, we have managed to decrease noise levels on the ward to 53dB on average. The success of this project to date has relied on the involvement of ward staff and carers - those most affected by the problem - in generating workable local solutions. As many of the change ideas amounted to harm free interventions it was easier for us to make a case to test them out in the real-life setting. Nevertheless we were surprised at how effective such seemingly simple ideas have been in improving the environment on the ward. We have incorporated the change ideas into routine practice and are advising other wards on similar projects.
An Analysis of Recent Measurements of the Temperature of the Cosmic Microwave Background Radiation
DOE R&D Accomplishments Database
Smoot, G.; Levin, S. M.; Witebsky, C.; De Amici, G.; Rephaeli, Y.
1987-07-01
This paper presents an analysis of the results of recent temperature measurements of the cosmic microwave background radiation (CMBR). The observations for wavelengths longer than 0.1 cum are well fit by a blackbody spectrum at 2.74{+ or -}0.0w K; however, including the new data of Matsumoto et al. (1987) the result is no longer consistent with a Planckian spectrum. The data are described by a Thomson-distortion parameter u=0.021{+ or -}0.002 and temperature 2.823{+ or -}0.010 K at the 68% confidence level. Fitting the low-frequency data to a Bose-Einstein spectral distortion yields a 95% confidence level upper limit of 1.4 x 10{sup -2} on the chemical potential mu{sub 0}. These limits on spectral distortions place restrictions on a number of potentially interesting sources of energy release to the CMBR, including the hot intergalactic medium proposed as the source of the X-ray background.
Lahmann, B; Milanese, L M; Han, W; Gatu Johnson, M; Séguin, F H; Frenje, J A; Petrasso, R D; Hahn, K D; Jones, B
2016-11-01
A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protons at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lahmann, B.; Milanese, L. M.; Han, W.
A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protonsmore » at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. In conclusion, these results are in excellent agreement with previous work applied to DT neutrons.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lahmann, B., E-mail: lahmann@mit.edu; Milanese, L. M.; Han, W.
A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protonsmore » at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. These results are in excellent agreement with previous work applied to DT neutrons.« less
Horowitz, A.J.; Elrick, K.A.; Demas, C.R.; Demcheck, D.K.
1991-01-01
Studies have demonstrated the utility of fluvial bed sediment chemical data in assesing local water-quality conditions. However, establishing local background trace element levels can be difficult. Reference to published average concentrations or the use of dated cores are often of little use in small areas of diverse local petrology, geology, land use, or hydrology. An alternative approach entails the construction of a series of sediment-trace element predictive models based on data from environmentally diverse but unaffected areas. Predicted values could provide a measure of local background concentrations and comparison with actual measured concentrations could identify elevated trace elements and affected sites. Such a model set was developed from surface bed sediments collected nationwide in the United States. Tests of the models in a small Louisiana basin indicated that they could be used to establish local trace element background levels, but required recalibration to account for local geochemical conditions outside the range of samples used to generate the nationwide models.
Lahmann, B.; Milanese, L. M.; Han, W.; ...
2016-07-20
A compact neutron spectrometer, based on a CH foil for the production of recoil protons and CR-39 detection, is being developed for the measurements of the DD-neutron spectrum at the NIF, OMEGA, and Z facilities. As a CR-39 detector will be used in the spectrometer, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). To reject the background to the required level for measurements of the down-scattered and primary DD-neutron components in the spectrum, the Coincidence Counting Technique (CCT) must be applied to the data. Using a piece of CR-39 exposed to 2.5-MeV protonsmore » at the MIT HEDP accelerator facility and DD-neutrons at Z, a significant improvement of a DD-neutron signal-to-background level has been demonstrated for the first time using the CCT. In conclusion, these results are in excellent agreement with previous work applied to DT neutrons.« less
Dolphins Adjust Species-Specific Frequency Parameters to Compensate for Increasing Background Noise
Papale, Elena; Gamba, Marco; Perez-Gil, Monica; Martin, Vidal Martel; Giacoma, Cristina
2015-01-01
An increase in ocean noise levels could interfere with acoustic communication of marine mammals. In this study we explored the effects of anthropogenic and natural noise on the acoustic properties of a dolphin communication signal, the whistle. A towed array with four elements was used to record environmental background noise and whistles of short-beaked common-, Atlantic spotted- and striped-dolphins in the Canaries archipelago. Four frequency parameters were measured from each whistle, while Sound Pressure Levels (SPL) of the background noise were measured at the central frequencies of seven one-third octave bands, from 5 to 20 kHz. Results show that dolphins increase the whistles’ frequency parameters with lower variability in the presence of anthropogenic noise, and increase the end frequency of their whistles when confronted with increasing natural noise. This study provides the first evidence that the synergy among SPLs has a role in shaping the whistles' structure of these three species, with respect to both natural and anthropogenic noise. PMID:25853825
Sherwin, Blake D; Dunkley, Joanna; Das, Sudeep; Appel, John W; Bond, J Richard; Carvalho, C Sofia; Devlin, Mark J; Dünner, Rolando; Essinger-Hileman, Thomas; Fowler, Joseph W; Hajian, Amir; Halpern, Mark; Hasselfield, Matthew; Hincks, Adam D; Hlozek, Renée; Hughes, John P; Irwin, Kent D; Klein, Jeff; Kosowsky, Arthur; Marriage, Tobias A; Marsden, Danica; Moodley, Kavilan; Menanteau, Felipe; Niemack, Michael D; Nolta, Michael R; Page, Lyman A; Parker, Lucas; Reese, Erik D; Schmitt, Benjamin L; Sehgal, Neelima; Sievers, Jon; Spergel, David N; Staggs, Suzanne T; Swetz, Daniel S; Switzer, Eric R; Thornton, Robert; Visnjic, Katerina; Wollack, Ed
2011-07-08
For the first time, measurements of the cosmic microwave background radiation (CMB) alone favor cosmologies with w = -1 dark energy over models without dark energy at a 3.2-sigma level. We demonstrate this by combining the CMB lensing deflection power spectrum from the Atacama Cosmology Telescope with temperature and polarization power spectra from the Wilkinson Microwave Anisotropy Probe. The lensing data break the geometric degeneracy of different cosmological models with similar CMB temperature power spectra. Our CMB-only measurement of the dark energy density Ω(Λ) confirms other measurements from supernovae, galaxy clusters, and baryon acoustic oscillations, and demonstrates the power of CMB lensing as a new cosmological tool.
NASA Technical Reports Server (NTRS)
Sherwin, Blake D.; Dunkley, Joanna; Das, Sudeep; Appel, John W.; Bond, J. Richard; Carvalho, C. Sofia; Devlin, Mark J.; Duenner, Rolando; Essinger-Hileman, Thomas; Fowler, Joesph J.;
2011-01-01
For the first time, measurements of the cosmic microwave background radiation (CMB) alone favor cosmologies with w = -1 dark energy over models without dark energy at a 3.2-sigma level. We demonstrate this by combining the CMB lensing deflection power spectrum from the Atacama Cosmology Telescope with temperature and polarization power spectra from the "Wilkinson Microwave Anisotropy Probe. The lensing data break the geometric degeneracy of different cosmological models with similar CMB temperature power spectra. Our CMB-only measurement of the dark energy density Omega(delta) confirms other measurements from supernovae, galaxy clusters and baryon acoustic oscillations, and demonstrates the power of CMB lensing as a new cosmological tool.
Across North America tracer experiment (ANATEX): Sampling and analysis
NASA Astrophysics Data System (ADS)
Draxler, R. R.; Dietz, R.; Lagomarsino, R. J.; Start, G.
Between 5 January 1987 and 29 March 1987, there were 33 releases of different tracers from each of two sites: Glasgow, MT and St. Cloud, MN. The perfluorocarbon tracers were routinely released in a 3-h period every 2.5 days, alternating between daytime and night-time tracer releases. Ground-level air samples of 24-h duration were taken at 77 sites mostly located near rawinsonde stations east of 105°W and between 26°N and 55°N. Weekly air samples were taken at 12 remote sites between San Diego, CA and Pt. Barrow, AK and between Norway and the Canary Islands. Short-term 6-h samples were collected at ground level and 200 m AGL along an arc of five towers between Tulsa, OK and Green Bay, WI. Aircraft sampling within several hundred kilometers of both tracer release sites was used to establish the initial tracer path. Experimental design required improved sampler performance, new tracers with lower atmospheric backgrounds, and improvements in analytic precision. The advances to the perfluorocarbon tracer system are discussed in detail. Results from the tracer sampling showed that the average and peak concentrations measured over the daily ground-level sampling network were consistent with what would be calculated using mass conservative approaches. however, ground-level samples from individual tracer patterns showed considerable complexity due to vertical stability or the interaction of the tracer plumes with low pressure and frontal systems. These systems could pass right through the tracer plume without appreciable effect. Aircraft tracer measurements are used to confirm the initial tracer trajectory when the narrow plume may miss the coarser spaced ground-level sampling network. Tower tracer measurements showed a more complex temporal structure than evident from the longer duration ground-level sampling sites. Few above background plume measurements were evident in the more distant remote sampling network due to larger than expected uncertainties in the ambient background concentrations.
2017-04-06
Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme Test (MRT) score as listed below...Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a minimum of ten talkers and of ten...listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication 6 DISTRIBUTION STATEMENT A: Approved for public release
2017-03-31
dB Sound Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme Test (MRT) score as listed...below. Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a minimum of ten talkers and of ten...listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication amplification. Test must include the configurations
NASA Technical Reports Server (NTRS)
Das, Sudeep; Marriage, Tobias A.; Ade, Peter A. R.; Aguirre, Paula; Amiri, Mandana; Appel, John W.; Barrientos, L. Felipe; Battistelli, Elia A.; Bond, J. Richard; Brown, Ben;
2010-01-01
We present measurements of the cosmic microwave background (CMB) power spectrum made by the Atacama Cosmology Telescope at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. Our results dearly show the second through the seventh acoustic peaks in the CMB power spectrum. The measurements of these higher-order peaks provide an additional test of the ACDM cosmological model. At l > 3000, we detect power in excess of the primary anisotropy spectrum of the CMB. At lower multipoles 500 < l < 3000, we find evidence for gravitational lensing of the CMB in the power spectrum at the 2.8(sigma) level. We also detect a low level of Galactic dust in our maps, which demonstrates that we can recover known faint, diffuse signals.
KCMP Minnesota Tall Tower Nitrous Oxide Inverse Modeling Dataset 2010-2015
Griffis, Timothy J. [University of Minnesota; Baker, John; Millet, Dylan; Chen, Zichong; Wood, Jeff; Erickson, Matt; Lee, Xuhui
2017-01-01
This dataset contains nitrous oxide mixing ratios and supporting information measured at a tall tower (KCMP, 244 m) site near St. Paul, Minnesot, USA. The data include nitrous oxide and carbon dioxide mixing ratios measured at the 100 m level. Turbulence and wind data were measured using a sonic anemometer at the 185 m level. Also included in this dataset are estimates of the "background" nitrous oxide mixing ratios and monthly concentration source footprints derived from WRF-STILT modeling.
Assessment of natural background radiation in one of the highest regions of Ecuador
NASA Astrophysics Data System (ADS)
Pérez, Mario; Chávez, Estefanía; Echeverría, Magdy; Córdova, Rafael; Recalde, Celso
2018-05-01
Natural background radiation was measured in the province of Chimborazo (Ecuador) with the following reference coordinates 1°40'00''S 78°39'00''W, where the furthest point to the center of the planet is located. Natural background radiation measurements were performed at 130 randomly selected sites using a Geiger Müller GCA-07W portable detector; these measurements were run at 6 m away from buildings or walls and 1 m above the ground. The global average natural background radiation established by UNSCEAR is 2.4 mSv y-1. In the study area measurements ranged from 0.57 mSv y-1 to 3.09 mSv y-1 with a mean value of 1.57 mSv y-1, the maximum value was recorded in the north of the study area at 5073 metres above sea level (m.a.s.l.), and the minimum value was recorded in the southwestern area at 297 m.a.s.l. An isodose map was plotted to represent the equivalent dose rate due to natural background radiation. An analysis of variance (ANOVA) between the data of the high and low regions of the study area showed a significant difference (p < α), in addition a linear correlation coefficient of 0.92 was obtained, supporting the hypothesis that in high altitude zones extraterrestrial radiation contributes significantly to natural background radiation.
Sub-visual Cirrus detection and characterization
NASA Technical Reports Server (NTRS)
Schmidt, E.; Grams, G.; Patterson, E.
1990-01-01
Analysis of archived cold optics (COR) radiometer data is yielding useful information on the diurnal, geographic, seasonal and altitude variability of atmospheric background radiance levels in the 11 micron window region. This database is a compilation of Kuiper Infrared Technology Experiment (KITE) and Atmospheric Radiance Study (ARS) observations under a wide variety of conditions. Correlating the measurements from these two studies with the LOWTRAN model code has revealed several important results. First, the 11 micron window appears to be filled-in, i.e., the troughs on either side of the nitric acid peak are shallower than expected. Second, the amplitude of the background radiances measured exceeds the model predictions by a factor of 2 to 3 or more. This is thought to be due to the existence of thin, high altitude cirrus clouds (sub-visual cirrus) above the sensor platform. These high background levels are observed under quiescent conditions in the South Pacific (Marshall Islands), as well as over the continental United States (the West Coast). In the tropics, there appears to be little diurnal variability, a plausible seasonal variation and a linear dependence between 7.2 and 11.4 micron band data, indicating possible multi-spectral approaches to detection of sub-visual cirrus clouds. Theoretical analysis of the magnitude of the effects of a sub-visual cirrus cloud on atmospheric background radiances measured by a near-horizontal sensor is in progress.
A silicon avalanche photodiode detector circuit for Nd:YAG laser scattering
NASA Astrophysics Data System (ADS)
Hsieh, C.-L.; Haskovec, J.; Carlstrom, T. N.; Deboo, J. C.; Greenfield, C. M.; Snider, R. T.; Trost, P.
1990-06-01
A silicon avalanche photodiode with an internal gain of about 50 to 100 is used in a temperature controlled environment to measure the Nd:YAG laser Thomson scattered spectrum in the wavelength range from 700 to 1150 nm. A charge sensitive preamplifier was developed for minimizing the noise contribution from the detector electronics. Signal levels as low as 20 photoelectrons (S/N = 1) can be detected. Measurements show that both the signal and the variance of the signal vary linearly with the input light level over the range of interest, indicating Poisson statistics. The signal is processed using a 100 ns delay line and a differential amplifier which subtracts the low frequency background light component. The background signal is amplified with a computer controlled variable gain amplifier and is used for an estimate of the measurement error, calibration, and Z sub eff measurements of the plasma. The signal processing was analyzed using a theoretical model to aid the system design and establish the procedure for data error analysis.
Silicon avalanche photodiode detector circuit for Nd:YAG laser scattering
NASA Astrophysics Data System (ADS)
Hsieh, C. L.; Haskovec, J.; Carlstrom, T. N.; DeBoo, J. C.; Greenfield, C. M.; Snider, R. T.; Trost, P.
1990-10-01
A silicon avalanche photodiode with an internal gain of about 50 to 100 is used in a temperature-controlled environment to measure the Nd:YAG laser Thomson scattered spectrum in the wavelength range from 700 to 1150 nm. A charge-sensitive preamplifier has been developed for minimizing the noise contribution from the detector electronics. Signal levels as low as 20 photoelectrons (S/N=1) can be detected. Measurements show that both the signal and the variance of the signal vary linearly with the input light level over the range of interest, indicating Poisson statistics. The signal is processed using a 100 ns delay line and a differential amplifier which subtracts the low-frequency background light component. The background signal is amplified with a computer-controlled variable gain amplifier and is used for an estimate of the measurement error, calibration, and Zeff measurements of the plasma. The signal processing has been analyzed using a theoretical model to aid the system design and establish the procedure for data error analysis.
Kovac, J M; Leitch, E M; Pryke, C; Carlstrom, J E; Halverson, N W; Holzapfel, W L
The past several years have seen the emergence of a standard cosmological model, in which small temperature differences in the cosmic microwave background (CMB) radiation on angular scales of the order of a degree are understood to arise from acoustic oscillations in the hot plasma of the early Universe, arising from primordial density fluctuations. Within the context of this model, recent measurements of the temperature fluctuations have led to profound conclusions about the origin, evolution and composition of the Universe. Using the measured temperature fluctuations, the theoretical framework predicts the level of polarization of the CMB with essentially no free parameters. Therefore, a measurement of the polarization is a critical test of the theory and thus of the validity of the cosmological parameters derived from the CMB measurements. Here we report the detection of polarization of the CMB with the Degree Angular Scale Interferometer (DASI). The polarization is deteced with high confidence, and its level and spatial distribution are in excellent agreement with the predictions of the standard theory.
SAGE II Measurements of Stratospheric Aerosol Properties at Non-Volcanic Levels
NASA Technical Reports Server (NTRS)
Thomason, Larry W.; Burton, Sharon P.; Luo, Bei-Ping; Peter, Thomas
2008-01-01
Since 2000, stratospheric aerosol levels have been relatively stable and at the lowest levels observed in the historical record. Given the challenges of making satellite measurements of aerosol properties at these levels, we have performed a study of the sensitivity of the product to the major components of the processing algorithm used in the production of SAGE II aerosol extinction measurements and the retrieval process that produces the operational surface area density (SAD) product. We find that the aerosol extinction measurements, particularly at 1020 nm, remain robust and reliable at the observed aerosol levels. On the other hand, during background periods, the SAD operational product has an uncertainty of at least a factor of 2 during due to the lack of sensitivity to particles with radii less than 100 nm.
Lahav, Orit; Apter, Alan; Ratzon, Navah Z
2013-01-01
This study evaluates how much the effects of intervention programs are influenced by pre-existing psychological adjustment and self-esteem levels in kindergarten and first grade children with poor visual-motor integration skills, from low socioeconomic backgrounds. One hundred and sixteen mainstream kindergarten and first-grade children, from low socioeconomic backgrounds, scoring below the 25th percentile on a measure of visual-motor integration (VMI) were recruited and randomly divided into two parallel intervention groups. One intervention group received directive visual-motor intervention (DVMI), while the second intervention group received a non-directive supportive intervention (NDSI). Tests were administered to evaluate visual-motor integration skills outcome. Children with higher baseline measures of psychological adjustment and self-esteem responded better in NDSI while children with lower baseline performance on psychological adjustment and self-esteem responded better in DVMI. This study suggests that children from low socioeconomic backgrounds with low VMI performance scores will benefit more from intervention programs if clinicians choose the type of intervention according to baseline psychological adjustment and self-esteem measures. Copyright © 2012 Elsevier Ltd. All rights reserved.
Microwave SQUID Multiplexer Demonstration for Cosmic Microwave Background Imagers.
Dober, B; Becker, D T; Bennett, D A; Bryan, S A; Duff, S M; Gard, J D; Hays-Wehle, J P; Hilton, G C; Hubmayr, J; Mates, J A B; Reintsema, C D; Vale, L R; Ullom, J N
2017-12-01
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.
Measurement of background gamma radiation in the northern Marshall Islands.
Bordner, Autumn S; Crosswell, Danielle A; Katz, Ainsley O; Shah, Jill T; Zhang, Catherine R; Nikolic-Hughes, Ivana; Hughes, Emlyn W; Ruderman, Malvin A
2016-06-21
We report measurements of background gamma radiation levels on six islands in the northern Marshall Islands (Enewetak, Medren, and Runit onEnewetak Atoll; Bikini and Nam on Bikini Atoll; and Rongelap on Rongelap Atoll). Measurable excess radiation could be expected from the decay of (137)Cs produced by the US nuclear testing program there from 1946 to 1958. These recordings are of relevance to safety of human habitation and resettlement. We find low levels of gamma radiation for the settled island of Enewetak [mean = 7.6 millirem/year (mrem/y) = 0.076 millisievert/year (mSv/y)], larger levels of gamma radiation for the island of Rongelap (mean = 19.8 mrem/y = 0.198 mSv/y), and relatively high gamma radiation on the island of Bikini (mean = 184 mrem/y = 1.84 mSv/y). Distributions of gamma radiation levels are provided, and hot spots are discussed. We provide interpolated maps for four islands (Enewetak, Medren, Bikini, and Rongelap), and make comparisons to control measurements performed on the island of Majuro in the southern Marshall Islands, measurements made in Central Park in New York City, and the standard agreed upon by the United States and the Republic of the Marshall Islands (RMI) governments (100 mrem/y = 1 mSv/y). External gamma radiation levels on Bikini Island significantly exceed this standard (P = <0.01), and external gamma radiation levels on the other islands are below the standard. To determine conclusively whether these islands are safe for habitation, radiation exposure through additional pathways such as food ingestion must be considered.
Measurement of background gamma radiation in the northern Marshall Islands
Bordner, Autumn S.; Crosswell, Danielle A.; Katz, Ainsley O.; Shah, Jill T.; Zhang, Catherine R.; Nikolic-Hughes, Ivana; Hughes, Emlyn W.; Ruderman, Malvin A.
2016-01-01
We report measurements of background gamma radiation levels on six islands in the northern Marshall Islands (Enewetak, Medren, and Runit onEnewetak Atoll; Bikini and Nam on Bikini Atoll; and Rongelap on Rongelap Atoll). Measurable excess radiation could be expected from the decay of 137Cs produced by the US nuclear testing program there from 1946 to 1958. These recordings are of relevance to safety of human habitation and resettlement. We find low levels of gamma radiation for the settled island of Enewetak [mean = 7.6 millirem/year (mrem/y) = 0.076 millisievert/year (mSv/y)], larger levels of gamma radiation for the island of Rongelap (mean = 19.8 mrem/y = 0.198 mSv/y), and relatively high gamma radiation on the island of Bikini (mean = 184 mrem/y = 1.84 mSv/y). Distributions of gamma radiation levels are provided, and hot spots are discussed. We provide interpolated maps for four islands (Enewetak, Medren, Bikini, and Rongelap), and make comparisons to control measurements performed on the island of Majuro in the southern Marshall Islands, measurements made in Central Park in New York City, and the standard agreed upon by the United States and the Republic of the Marshall Islands (RMI) governments (100 mrem/y = 1 mSv/y). External gamma radiation levels on Bikini Island significantly exceed this standard (P = <<0.01), and external gamma radiation levels on the other islands are below the standard. To determine conclusively whether these islands are safe for habitation, radiation exposure through additional pathways such as food ingestion must be considered. PMID:27274073
Listening Effort Through Depth of Processing in School-Age Children.
Hsu, Benson Cheng-Lin; Vanpoucke, Filiep; van Wieringen, Astrid
A reliable and practical measure of listening effort is crucial in the aural rehabilitation of children with communication disorders. In this article, we propose a novel behavioral paradigm designed to measure listening effort in school-age children based on different depths and levels of verbal processing. The paradigm consists of a classic word recognition task performed in quiet and in noise coupled to one of three additional tasks asking the children to judge the color of simple pictures or a certain semantic category of the presented words. The response time (RT) from the categorization tasks is considered the primary indicator of listening effort. The listening effort paradigm was evaluated in a group of 31 normal-hearing, normal-developing children 7 to 12 years of age. A total of 146 Dutch nouns were selected for the experiment after surveying 14 local Dutch-speaking children. Windows-based custom software was developed to administer the behavioral paradigm from a conventional laptop computer. A separate touch screen was used as a response interface to gather the RT data from the participants. Verbal repetition of each presented word was scored by the tester and a percentage-correct word recognition score (WRS) was calculated for each condition. Randomized lists of target words were presented in one of three signal to noise ratios (SNR) to examine the effect of background noise on the two outcome measures of WRS and RT. Three novel categorization tasks, each corresponding to a different depth or elaboration level of semantic processing, were developed to examine the effect of processing level on either WRS or RT. It was hypothesized that, while listening effort as measured by RT would be affected by both noise and processing level, WRS performance would be affected by changes in noise level only. The RT measure was also hypothesized to increase more from an increase in noise level in categorization conditions demanding a deeper or more elaborate form of semantic processing. There was a significant effect of SNR level on school-age children's WRS: their word recognition performance tended to decrease with increasing background noise level. However, depth of processing did not seem to affect WRS. Moreover, a repeated-measure analysis of variance fitted to transformed RT data revealed that this measure of listening effort in normal-hearing school-age children was significantly affected by both SNR level and the depth of semantic processing. There was no significant interaction between noise level and the type of categorization task with regard to RT. The observed patterns of WRS and RT supported the hypotheses regarding the effects of background noise and depth of processing on word recognition performance and a behavioral measure of listening effort. The magnitude of noise-induced change in RT did not differ between categorization tasks, however. Our findings point to future research directions regarding the potential effects of age, working memory capacity, and cross-modality interaction when measuring listening effort in different levels of semantic processing.
NASA Technical Reports Server (NTRS)
Evans, D. C.
1983-01-01
The Diffuse Infrared Background Experiment (DIRBE) is a 10 band filter photometer that will operate at superfluid helium temperatures. Diffuse galactic and extragalactic infrared radiation in the 1-300 micrometer wavelength region will be measured by the instrument. Polarization measurements will be made for 3 bands in the 1-4 micrometer spectral region. The main sources of unwanted radiation are the sun, earth, thermal radiation from an external sun shield, the moon, the brighter planets and stars, and sky light itself from outside the instrument's nominal one degree square field of view. The system level engineering concepts and the principles of stray light suppression that resulted in the instrument design are presented.
Low-background performance of a monolithic InSb CCD array
NASA Technical Reports Server (NTRS)
Bregman, J. D.; Goebel, J. H.; Mccreight, C. R.; Matsumoto, T.
1982-01-01
A 20 element monolithic InSb charge coupled device (CCD) detector array was measured under low background conditions to assess its potential for orbital astronomical applications. At a temperature of 64 K, previous results for charge transfer efficiency (CTE) were reproduced, and a sensitivity of about 2 x 10 to the minus 15th power joules was measured. At 27 and 6 K, extended integration times were achieved, but CTE was substantially degraded. The noise was approximately 6000 charges, which was in excess of the level where statistical fluctuations from the illumination could be detected. A telescope demonstration was performed showing that the array sensitivity and difficulty of operation were not substantially different from laboratory levels. Ways in which the device could be improved for astronomical applications were discussed.
Development of a Low-Level Ar-37 Calibration Standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Richard M.; Aalseth, Craig E.; Bowyer, Ted W.
Argon-37 is an important environmental signature of an underground nuclear explosion. Producing and quantifying low-level 37Ar standards is an important step in the development of sensitive field measurement instruments for use during an On-Site Inspection, a key provision of the Comprehensive Nuclear-Test-Ban Treaty. This paper describes progress at Pacific Northwest National Laboratory (PNNL) in the development of a process to generate and quantify low-level 37Ar standard material, which can then be used to calibrate sensitive field systems at activities consistent with soil background levels. The 37Ar used for our work was generated using a laboratory-scale, high-energy neutron source to irradiatemore » powdered samples of calcium carbonate. Small aliquots of 37Ar were then extracted from the head space of the irradiated samples. The specific activity of the head space samples, mixed with P10 (90% stable argon:10% methane by mole fraction) count gas, is then derived using the accepted Length-Compensated Internal-Source Proportional Counting method. Due to the low activity of the samples, a set of three Ultra-Low Background Proportional-Counters designed and fabricated at PNNL from radio-pure electroformed copper was used to make the measurements in PNNL’s shallow underground counting laboratory. Very low background levels (<10 counts/day) have been observed in the spectral region near the 37Ar emission feature at 2.8 keV. Two separate samples from the same irradiation were measured. The first sample was counted for 12 days beginning 28 days after irradiation, the second sample was counted for 24 days beginning 70 days after irradiation (the half-life of 37Ar is 35.0 days). Both sets of measurements were analyzed and yielded very similar results for the starting activity (~0.1 Bq) and activity concentration (0.15 mBq/ccSTP argon) after P10 count gas was added. A detailed uncertainty model was developed based on the ISO Guide to the Expression of Uncertainty in Measurement. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.« less
NASA Astrophysics Data System (ADS)
Gaffney, Jeffrey S.; Marley, Nancy A.; Blake, Donald R.
2012-09-01
While it is well known that combustion of ethanol as a biofuel will lead to enhanced emissions of methane, ethene (ethylene), acetaldehyde, formaldehyde, and oxides of nitrogen (primarily NO) when compared to gasoline alone, especially during cold starts or if catalytic converters are not operating properly, the impacts of increases in atmospheric ethene levels from combustion of fuels with higher ethanol content has not received much attention. Ethene is a well known and potent plant growth hormone and exposure to agricultural crops and natural vegetation results in yield reductions especially when combined with higher levels of PAN and ozone also expected from the increased use of ethanol/gasoline blends. We report here some baseline measurements of ethene obtained in 2002 in the southwestern and south central United States. These data indicate that current ethene background levels are less than 1 ppb. Anticipated increases in fuel ethanol content of E30 or greater is expected to lead to higher atmospheric levels of ethene on regional scales due to its atmospheric lifetime of 1.5-3 days. These background measurements are discussed in light of the potential enhancement of ethene levels expected from the anticipated increases in ethanol use as a renewable biofuel.
NASA Astrophysics Data System (ADS)
Ono-Ogasawara, Mariko; Serita, Fumio; Takaya, Mitsutoshi
2009-10-01
As the production of engineered nanomaterials quantitatively expands, the chance that workers involved in the manufacturing process will be exposed to nanoparticles also increases. A risk management system is needed for workplaces in the nanomaterial industry based on the precautionary principle. One of the problems in the risk management system is difficulty of exposure assessment. In this article, examples of exposure assessment in nanomaterial industries are reviewed with a focus on distinguishing engineered nanomaterial particles from background nanoparticles in workplace atmosphere. An approach by JNIOSH (Japan National Institute of Occupational Safety and Health) to quantitatively measure exposure to carbonaceous nanomaterials is also introduced. In addition to real-time measurements and qualitative analysis by electron microscopy, quantitative chemical analysis is necessary for quantitatively assessing exposure to nanomaterials. Chemical analysis is suitable for quantitative exposure measurement especially at facilities with high levels of background NPs.
NASA Astrophysics Data System (ADS)
Matthews, James; Wright, Matthew; Bacak, Asan; Silva, Hugo; Priestley, Michael; Martin, Damien; Percival, Carl; Shallcross, Dudley
2016-04-01
Cyclic perfluorocarbons (PFCs) have been used to measure the passage of air in urban and rural settings as they are chemically inert, non-toxic and have low background concentrations. The use of pre-concentrators and chemical ionisation gas chromatography enables concentrations of a few parts per quadrillion (ppq) to be measured in bag samples. Three PFC tracers were used in Manchester, UK in the summer of 2015 to map airflow in the city and ingress into buildings: perfluomethylcyclohexane (PMCH), perfluoro-2-4-dimethylcyclohexane (mPDMCH) and perfluoro-2-methyl-3-ethylpentene (PMEP). A known quantity of each PFC was released for 15 minutes from steel canisters using pre-prepared PFC mixtures. Release points were chosen to be upwind of the central sampling location (Simon Building, University of Manchester) and varied in distance up to 2.2 km. Six releases using one or three tracers in different configurations and under different conditions were undertaken in the summer. Three further experiments were conducted in the Autumn, to more closely investigate the rate of ingress and decay of tracer indoors. In each experiment, 10 litre samples were made over 30 minutes into Tedlar bags, starting at the same time the as PFC release. Samples were taken in 11 locations chosen from 15 identified areas including three in public parks, three outside within the University of Manchester area, seven inside and five outside of the Simon building and two outside a building nearby. For building measurements, receptors were placed inside the buildings on different floors; outside measurements were achieved through a sample line out of the window. Three of the sample positions inside the Simon building were paired with samplers outside to allow indoor-outdoor comparisons. PFC concentrations varied depending on location and height. The highest measured concentrations occurred when the tracer was released at sunrise; up to 330 ppq above background (11 ppq) of PMCH was measured at the 6th floor of the Simon Building from a release 1.9 km away. One experiment sampled for an additional two 30 minute periods in four locations inside and one location outside the Simon Building in order to investigate how long it took for air to enter and leave the building. For this measurement, 1.3 g of PMCH was released 1.9 km away and average roof level wind speed was 7.8 m/s. The highest measurement of PMCH outside was 54 ppq above background, and 46 ppq inside. After the first 30 minutes, the PFC concentration returned to background levels outside, but other internal rooms still had elevated PFC concentrations between 10 and 16 ppq above background an hour after release demonstrating that pollutants may persist within buildings having passed outside. In the final experiment, the wind direction changed so the sampling locations were not directly downwind of the release point, but nevertheless a small amount of PFC tracer above background was detected at the highest sampling point on the 6th floor of the Simon Building (14 ppq above background), and a smaller amount at street level.
Correlation Between Arterial FDG Uptake and Biomarkers in Peripheral Artery Disease
Myers, Kelly S.; Rudd, James H. F.; Hailman, Eric P.; Bolognese, James A.; Burke, Joanne; Pinto, Cathy Anne; Klimas, Michael; Hargreaves, Richard; Dansky, Hayes M.; Fayad, Zahi A.
2014-01-01
OBJECTIVES A prospective, multicenter 18fluorine-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) imaging study was performed to estimate the correlations among arterial FDG uptake and atherosclerotic plaque biomarkers in patients with peripheral artery disease. BACKGROUND Inflammation within atherosclerotic plaques is associated with instability of the plaque and future cardiovascular events. Previous studies have shown that 18F-FDG-PET/CT is able to quantify inflammation within carotid artery atherosclerotic plaques, but no studies to date have investigated this correlation in peripheral arteries with immunohistochemical confirmation. METHODS Thirty patients across 5 study sites underwent 18F-FDG-PET/CT imaging before Silver-Hawk atherectomy (FoxHollow Technologies, Redwood City, California) for symptomatic common or superficial femoral arterial disease. Vascular FDG uptake (expressed as target-to-background ratio) was measured in the carotid arteries and aorta and femoral arteries, including the region of atherectomy. Immunohistochemistry was performed on the excised atherosclerotic plaque extracts, and cluster of differentiation 68 (CD68) level as a measure of macrophage content was determined. Correlations between target-to-background ratio of excised lesions, as well as entire arterial regions, and CD68 levels were determined. Imaging was performed during the 2 weeks before surgery in all cases. RESULTS Twenty-one patients had adequate-quality 18F-FDG-PET/CT peripheral artery images, and 34 plaque specimens were obtained. No significant correlation between lesion target-to-background ratio and CD68 level was observed. CONCLUSIONS There were no significant correlations between CD68 level (as a measure of macrophage content) and FDG uptake in the peripheral arteries in this multicenter study. Differences in lesion extraction technique, lesion size, the degree of inflammation, and imaging coregistration techniques may have been responsible for the failure to observe the strong correlations with vascular FDG uptake observed in previous studies of the carotid artery and in several animal models of atherosclerosis. PMID:22239891
Particulate sulphate and ozone in rural air: Preliminary results from three sites in central England
NASA Astrophysics Data System (ADS)
Martin, A.; Barber, F. R.
Daily particulate sulphate concentrations in air have been measured at a 'background' rural site and at two other sites near rural power stations. The samples were collected by drawing air through filter papers and were analysed by X-ray fluorescence. At the background site the concentration of particulate sulphates was strongly dependent on the O 3 and total S in air. Above a certain 'critical' level of daily O 3, 28% of the daily S in air was particulate on average, but the amounts were not related to the actual O 3 levels. At lower O 3 levels, there appeared to be a constant background of about 2 μg of particulate sulphate per cubic meter of air, together with about 5% of the total S in air as particulate. When black smoke in air was low, the particulate sulphate was also low, despite the O 3 levels. Near the power stations, there was no significantly different rate of production or loss of particulate sulphate. On average, at all three sites over the year, about 12% of the daily total S was particulate, probably corresponding to an average conversion rate of SO 2 of less than 1% per hour. Estimates of hourly particulate sulphates are available from previous measurements at the background site, using a different analysis technique. Particulate sulphate was not found every hour, but typically during 20 h a day in early summer and 8 h a day in early winter. An influence of humidity as well as O 3 was apparent in the peak hourly particulate sulphate values, which reached 60% of the total S. No correlation could be found of particulate sulphate with solar radiation, wind direction, concentrations of oxides of nitrogen in air or ammonium or sulphate in rainwater, but further measurements are planned.
Our laboratory has developed methods for measuring the expression of the vitellogenin (Vg) gene in larval and adult male fathead minnows. During this development we found several conditions that affect background Vg levels and we observed preconditions for the expression of this...
Effects of pedagogical ideology on the perceived loudness and noise levels in preschools.
Jonsdottir, Valdis; Rantala, Leena M; Oskarsson, Gudmundur Kr; Sala, Eeva
2015-01-01
High activity noise levels that result in detrimental effects on speech communication have been measured in preschools. To find out if different pedagogical ideologies affect the perceived loudness and levels of noise, a questionnaire study inquiring about the experience of loudness and voice symptoms was carried out in Iceland in eight private preschools, called "Hjalli model", and in six public preschools. Noise levels were also measured in the preschools. Background variables (stress level, age, length of working career, education, smoking, and number of children per teacher) were also analyzed in order to determine how much they contributed toward voice symptoms and the experience of noisiness. Results indicate that pedagogical ideology is a significant factor for predicting noise and its consequences. Teachers in the preschool with tighter pedagogical control of discipline (the "Hjalli model") experienced lower activity noise loudness than teachers in the preschool with a more relaxed control of behavior (public preschool). Lower noise levels were also measured in the "Hjalli model" preschool and fewer "Hjalli model" teachers reported voice symptoms. Public preschool teachers experienced more stress than "Hjalli model" teachers and the stress level was, indeed, the background variable that best explained the voice symptoms and the teacher's perception of a noisy environment. Discipline, structure, and organization in the type of activity predicted the activity noise level better than the number of children in the group. Results indicate that pedagogical ideology is a significant factor for predicting self-reported noise and its consequences.
A medium-scale measurement of the cosmic microwave background at 3.3 millimeters
NASA Technical Reports Server (NTRS)
Meinhold, Peter; Lubin, Philip
1991-01-01
A system has been developed for making measurements of spatial fluctuations in the cosmic microwave background radiation, on an angular scale of 5 arcmin to a few degrees. The system consists of an off-axis Gregorian telescope with a nearly Gaussian response with FWHM adjustable from 20 to 50 arcmin, an SIS coherent receiver operating at 3.3 mm, and a pointing system capable of better than 1 arcmin rms stabilization. This paper reports on results from the system's first balloon flight in August 1988, and ground-based measurements made from the South Pole in December 1988. A portion of the South Pole data is used to place a 95-percent confidence level upper limit of Delta T/T less than 0.000035 for Gaussian sky fluctuations in the background radiation at 20-arcmin angular scale and a limit of Delta T/T less than 0.000033 on overall excess intrinsic sky noise. In addition, dust contamination in cosmic background radiation data is estimated using measurements of the Galaxy from this flight and a previous one, along with the IRAS 100-micron map. These anisotropy results give the most stringent limits on cold dark matter theories to date.
Background Acoustics Levels in the 9x15 Wind Tunnel and Linear Array Testing
NASA Technical Reports Server (NTRS)
Stephens, David
2011-01-01
The background noise level in the 9x15 foot wind tunnel at NASA Glenn has been documented, and the results compare favorably with historical measurements. A study of recessed microphone mounting techniques was also conducted, and a recessed cavity with a micronic wire mesh screen reduces hydrodynamic noise by around 10 dB. A three-microphone signal processing technique can provide additional benefit, rejecting up to 15 dB of noise contamination at some frequencies. The screen and cavity system offers considerable benefit to test efficiency, although there are additional calibration requirements.
2017-03-01
in an environment 71-115 dB Sound Pressure Level (SPL) background pink noise. The speech intelligibility tests shall result in a Modified Rhyme... Test (MRT) score as listed below. Speech intelligibility testing shall be measured per ANSI S3.2 for each background pink noise level using a...minimum of ten talkers and of ten listeners. The test shall be conducted wearing the JSAM-TA using appropriate communication amplification. Test must
Quantifying the contribution of individual vehicles to NO2 pollution in an urban area
NASA Astrophysics Data System (ADS)
Pöhler, Denis; Kanatschnig, Florian; Horbanski, Martin; Friedrich, Axel; Lampel, Johannes; Platt, Ulrich
2015-04-01
Nitrogen Dioxide (NOx) emissions by road vehicles are the mayor contributor for poor air quality in urban areas. High NOx concentrations, and especially NO2, are typically the most problematic pollutant in mega and other cities. However emissions vary significantly depending on the type of vehicle and its engine, the age and condition of the vehicle, driving properties and many more. Even if data of the manufacturer exists how much NOx different vehicle types emit, reliable data under real driving conditions are rare and often missing. Especially data showing the degree to which different cars contribute to observed NOx levels are missing. Significant reduction of NOx concentrations can be achieved by identifying the strong emitting vehicles and excluding / replacing these. As this is only a small amount of vehicles (typically less than 10% of the vehicles make 90% of the emissions), such a small investment can significantly improve air quality. In order to perform measurements of NOx we applied a high speed NO2 CE-DOAS (Cavity-Enhanced DOAS) instrument in a car which was modified for this application. It measured directly the NO2 concentration behind followed vehicles while driving, with a time resolution of 2 s and an accuracy of ~1ppb. Even if such observations depend on many parameters like mixing-in of ambient air, distance, solar radiation, ozone concentration, background concentration etc., it delivers valuable data under real driving conditions. The instrument was applied in the city of Mainz, Germany to investigate within 7 days (March / April 2014) the NOx emission of 728 vehicles and to quantify the main emitters. Therefore the measured NO2 concentration in comparison to the background concentrations was quantified. Observed vehicles were separated in 4 categories: cars, busses, trucks, and motorcycles. We observed NO2 levels from a few ppb (within the background variation) up to 7000ppb NO2 above the background level. Strong variations within the same vehicle category could be observed. NO2 levels above 500ppb are found only for 2,2% of all measured vehicles and these are mainly busses (especially older models) but also few cars and motorcycles. On average NO2 concentrations behind the vehicles were 222ppb above background level. This could be reduced by 45% by just excluding the strongest emitters (2,2% of all vehicles). Our study clearly shows which vehicles exhibit the strongest NO2 emissions under real driving conditions and which vehicles contribute most to urban NOx pollution. It demonstrates how such measurements at high temporal resolution on a mobile platform can give recommendations to policy makers to significantly improve air quality in mega and other cities at moderate cost. In the future our system will be expanded with a NO and O3 measurement system to quantify all relevant species.
Photovoltaic system test facility electromagnetic interference measurements
NASA Technical Reports Server (NTRS)
Johnson, J. A.; Herke, F. P., Jr.; Knapp, W. D.
1977-01-01
Field strength measurements on a single row of panels indicates that the operational mode of the array as configured presents no radiated EMI problems. Only one relatively significant frequency band near 200 kHz showed any degree of intensity (9 muV/m including a background level of 5 muV/m). The level was measured very near the array (at 20 ft distance) while Federal Communications Commission (FCC) regulations limit spurious emissions to 15 muV/m at 1,000 ft. No field strength readings could be obtained even at 35 ft distant.
Preliminary measurements of 135Cs with AMS
NASA Astrophysics Data System (ADS)
Yin, Xinyi; He, Ming; Dong, Kejun; Dou, Liang; Lan, Xiaoxi; Pang, Fangfang; Wu, Shaoyong; Jiang, Shan
2015-10-01
135Cs is an interesting nuclide in many research fields, especially in environmental study. Preliminary measurements of the long-lived 135Cs with accelerator mass spectrometry (AMS) have been developed with the HI-13 tandem AMS facility at China Institute of Atomic Energy (CIAE). In order to improve ion extracting current and depressing background interference, experiments were carried out on different ions of Cs extracted from different samples. It was found that Cs- extracted from CsNO3 can be used for AMS measurement of 135Cs. According to the preliminary results, the background level can be obtained with blanks was 135Ba/Cs ∼ 8.8 × 10-12 with the CIAE-AMS system.
Post-PRK corneal scatter measurements with a scanning confocal slit photon counter
NASA Astrophysics Data System (ADS)
Taboada, John; Gaines, David; Perez, Mary A.; Waller, Steve G.; Ivan, Douglas J.; Baldwin, J. Bruce; LoRusso, Frank; Tutt, Ronald C.; Perez, Jose; Tredici, Thomas; Johnson, Dan A.
2000-06-01
Increased corneal light scatter or 'haze' has been associated with excimer laser photorefractive surgery of the cornea. The increased scatter can affect visual performance; however, topical steroid treatment post surgery substantially reduces the post PRK scatter. For the treatment and monitoring of the scattering characteristics of the cornea, various methods have been developed to objectively measure the magnitude of the scatter. These methods generally can measure scatter associated with clinically observable levels of haze. For patients with moderate to low PRK corrections receiving steroid treatment, measurement becomes fairly difficult as the haze clinical rating is non observable. The goal of this development was to realize an objective, non-invasive physical measurement that could produce a significant reading for any level including the background present in a normal cornea. As back-scatter is the only readily accessible observable, the instrument is based on this measurement. To achieve this end required the use of a confocal method to bias out the background light that would normally confound conventional methods. A number of subjects with nominal refractive errors in an Air Force study have undergone PRK surgery. A measurable increase in corneal scatter has been observed in these subjects whereas clinical ratings of the haze were noted as level zero. Other favorable aspects of this back-scatter based instrument include an optical capability to perform what is equivalent to an optical A-scan of the anterior chamber. Lens scatter can also be measured.
An accurate laser radiometer for determining visible exposure times.
Royston, D D
1985-01-01
A laser light radiometer has been developed for the Electro-Optics Branch of the Center for Devices and Radiological Health (CDRH). The radiometer measures direct laser radiation emitted in the visible spectrum. Based upon this measurement, the instrument's microprocessor automatically determines at what time duration the exposure to the measured laser radiation would exceed either the class I accessible emission limits of the Federal Performance Standard for laser products or the maximum permissible exposure limits of laser user safety standards. The instrument also features automatic background level compensation, pulse measurement capability, and self-diagnosis. Measurement of forward surface illumination levels preceding HpD photoradiation therapy is possible.
Daily physical activity and sports participation among children from ethnic minorities in Denmark.
Nielsen, Glen; Hermansen, Bianca; Bugge, Anna; Dencker, Magnus; Andersen, Lars Bo
2013-01-01
The purpose of this study was to investigate whether Danish children from immigrant backgrounds are less physically active than children from the ethnic majority, and to investigate the possible reasons for any differences found. Accelerometer measures of physical activity as well as questionnaire data about organised sports, family demography, resources and values were collected from 594 children of whom 67 had other ethnic background than Danish. Data were collected when the children were 6-7 years old and again later when the children were 9-10 years old. It was found that children from immigrant backgrounds were not less physically active than other children when their amounts of daily physical activity were measured by direct objective measures, despite their participation rate in organised sports being much lower. Using multiple logistic regression modelling, this study showed that lack of parental experience with organised sports and lack of economic/material resources explained much of the difference in sports participation. Children of immigrant background had significant lower participation in club sports but this did not affect their overall physical activity level.
Characterization and Evolution of the Swift X-ray Telescope Instrumental Background
NASA Technical Reports Server (NTRS)
Hill, Joanne; Pagani, C.; Morris, D. C.; Racusin, J.; Grupe, D.; Vetere, L.; Stroh, M.; Falcone, A.; Kennea, J.; Burrows, D. N.;
2007-01-01
The X-ray telescope (XRT) on board the Swift Gamma Ray Burst Explorer has successfully operated since the spacecraft launch on 20 November 2004, automatically locating GRB afterglows, measuring their spectra and lightcurves and performing observations of high-energy sources. In this work we investigate the properties of the instrumental background, focusing on its dynamic behavior on both long and short timescales. The operational temperature of the CCD is the main factor that influences the XRT background level. After the failure of the Swift active on-board temperature control system, the XRT detector now operates at a temperature range between -75C and -45C thanks to a passive cooling Heat Rejection System. We report on the long-term effects on the background caused by radiation, consisting mainly of proton irradiation in Swift's low Earth orbit and on the short-term effects of transits through the South Atlantic Anomaly (SAA), which expose the detector to periods of intense proton flux. We have determined the fraction of the detector background that is due to the internal, instrumental background and the part that is due to unresolved astrophysical sources (the cosmic X-ray background) by investigating the degree of vignetting of the measured background and comparing it to the expected value from calibration data.
ERIC Educational Resources Information Center
Sandoval, Anna; Turner, Lindsey; Nicholson, Lisa; Chriqui, Jamie; Tortorelli, Megan; Chaloupka, Frank J.
2012-01-01
Background: School-based measurement of children's body mass index (BMI) is a useful tool for tracking childhood obesity rates, and may be an effective intervention strategy for reducing the increasing trends in obesity. This article examines the relationship between state law, district policy, and school-level BMI measurement practices.…
NASA Astrophysics Data System (ADS)
Mathur, R.; Kang, D.; Napelenok, S. L.; Xing, J.; Hogrefe, C.
2017-12-01
Air pollution reduction strategies for a region are complicated not only by the interplay of local emissions sources and several complex physical, chemical, dynamical processes in the atmosphere, but also hemispheric background levels of pollutants. Contrasting changes in emission patterns across the globe (e.g. declining emissions in North America and Western Europe in response to implementation of control measures and increasing emissions across Asia due to economic and population growth) are resulting in heterogeneous changes in the tropospheric chemical composition and are likely altering long-range transport impacts and consequently background pollution levels at receptor regions. To quantify these impacts, the WRF-CMAQ model is expanded to hemispheric scales and multi-decadal model simulations are performed for the period spanning 1990-2010 to examine changes in hemispheric air pollution resulting from changes in emissions over this period. Simulated trends in ozone and precursor species concentrations across the U.S. and the Northern Hemisphere over the past two decades are compared with those inferred from available measurements during this period. Additionally, the decoupled direct method (DDM) in CMAQ, a first- and higher-order sensitivity calculation technique, is used to estimate the sensitivity of O3 to emissions from different source regions across the Northern Hemisphere. The seasonal variations in source region contributions to background O3 are then estimated from these sensitivity calculations and will be discussed. These source region sensitivities estimated from DDM are then combined with the multi-decadal simulations of O3 distributions and emissions trends to characterize the changing contributions of different source regions to background O3 levels across North America. This characterization of changing long-range transport contributions is critical for the design and implementation of tighter national air quality standards
NASA Astrophysics Data System (ADS)
Hardesty, R. M.; Senff, C. J.; Alvarez, R. J.; Banta, R. M.; Sandberg, S. P.; Weickmann, A. M.; Darby, L. S.
2007-12-01
A new all solid state ozone lidar was deployed on a NOAA Twin Otter to study boundary layer ozone and aerosol, mostly around Houston, during the 2006 Texas Air Quality Study. The new instrument transmits high pulse-rate, low pulse-energy light at 3 wavelengths in the ultraviolet to obtain ozone profiles with 500 m horizontal resolution and 90 m vertical resolution. During the Texas field study, 20 research flights resulted in nearly 70 hours of ozone measurements during the period from August 1 to September 15. Science objectives included characterization of background ozone levels over rural areas near Houston and Dallas and variability and structure of the boundary layer over different surface types, including urban, wooded, and agricultural land surface areas as well as over Galveston Bay and the Gulf of Mexico. A histogram of all boundary layer ozone concentration measurements showed a bimodal distribution with modes at 45 ppb and 70 ppb. The lower mode correlated with southerly flow, when relatively clean air was transported onshore into the Houston area. Segmenting the observations during southerly flow by region, including the Gulf of Mexico, land within about 55 km from the coast, and further inland indicated that background levels increased by about 10 ppb as air was transported onshore. During the latter part of the experiment, as more pollution was imported into the Houston region, background levels rose to nearly 80 ppb in regions N of Houston. Two flights aimed at observing import of ozone into Texas from the east showed that ozone concentrations increased and boundary layer depths deepened upwind of Houston between September 4 and September 8. Background levels rose by more than 10 ppb over this period. In addition to ozone measurements, we also estimated boundary layer height based on maximum gradient in observed backscatter. The technique worked well when the layer topped by the strongest gradient extends down to the surface. Investigation of the correlation between ozone levels and mixing layer heights both within and external to the Houston urban plume showed a variety of relationships, depending on, e.g., wind direction and occurrence of a bay/gulf breeze. On a day-to-day basis, higher ozone levels were weakly correlated with deeper mixing levels - this was likely due to advection of the urban heat island downwind with the high-ozone urban plume.
Background suppressed measurements of the Low Energy CVV Auger transitions in Cu and Ag(100)
NASA Astrophysics Data System (ADS)
Shastry, K.; Mukherjee Mukherjee, S.; Kalaskar, S.; Hulbert, S. L.; Bartynski, B. R.; Weiss, A. H.
2010-10-01
Low energy Auger lineshapes are difficult to measure because they sit on a large background due to secondary electrons arising from loss processes unrelated to the Auger mechanism. Auger photoelectron coincidence spectroscopy (APECS) was used to the spectrum of the MVV and NVV Auger peaks and associated low energy tails (LETs) in Cu and Ag (100) respectively. The backgrounds due to secondary electrons unrelated to the auger process were suppressed by measuring the Auger spectra in coincidence with the M and N core levels. The APECS measurements reveal a well formed Auger peak at 40 and 60 eV for Cu and Ag respectively accompanied by a significant Auger related intensity in the low energy region. Spectra obtained using APECS are compared with Positron Annihilation Induced Auger Electron Spectroscopy (PAES) measurements which also show a large LET. The LET is discussed in terms of extrinsic mechanisms in which the electrons from the peak lose energy as they propagate to the sample surface and intrinsic mechanisms in which multi- electron auger processes distribute the energy gained by filling of the core hole to multiple electrons.
Hua, Håkan; Emilsson, Magnus; Kähäri, Kim; Widén, Stephen; Möller, Claes; Lyxell, Björn
2014-10-01
Health care professionals frequently meet employees with hearing impairment (HI) who experience difficulties at work. There are indications that the majority of these difficulties might be related to the presence of background noise. Moreover, research has also shown that high-level noise has a more detrimental effect on cognitive performance and self-rated disturbance in individuals with HI than low-level noise. The purpose of this study was to examine the impact of different types of background noise on cognitive performance and perceived disturbance (PD) in employees with aided HI and normal hearing. A mixed factorial design was conducted to examine the effect of noise in four experimental conditions. A total of 40 participants (21 men and 19 women) were recruited to take part in the study. The study sample consisted of employees with HI (n = 20) and normal hearing (n = 20). The group with HI had a mild-moderate sensorineural HI, and they were all frequent hearing-aid users. The current study was conducted by using four general work-related tasks (mental arithmetic, orthographic decoding, phonological decoding, and serial recall) in four different background conditions: (1) quiet, (2) office noise at 56 dBA, (3) daycare noise at 73.5 dBA, and (4) traffic noise at 72.5 dBA. Reaction time and the proportion of correct answers in the working tasks were used as outcome measures of cognitive performance. The Borg CR-10 scale was used to assess PD. Data collection occurred on two separate sessions, completed within 4 wk of each other. All tasks and experimental conditions were used in a counterbalanced order. Two-way analysis of variance with repeated measures was performed to analyze the results. To examine interaction effects, pairwise t-tests were used. Pearson correlation coefficients between reaction time and proportion of correct answers, and cognitive performance and PD were also calculated to examine the possible correlation between the different variables. No significant between-group or within-group differences in cognitive performance were observed across the four background conditions. Ratings of PD showed that both groups rated PD according to noise level, where higher noise level generated a higher PD. The present findings also demonstrated that the group with HI was more disturbed by higher than lower levels of noise (i.e., traffic and daycare setting compared with office setting). This pattern was observed consistently throughout four working tasks where the group with HI reported a significantly greater PD in the daycare and traffic settings compared with office noise. The present results demonstrate that background noise does not impair cognitive performance in nonauditory tasks in employees with HI and normal hearing, but that PD is affected to a greater extent in employees with HI during higher levels of background noise exposure. In addition, this study also supports previous studies regarding the detrimental effects that high-level noise has on employees with HI. Therefore, we emphasize the need of both self-rated and cognitive measurements in hearing care and occupational health services for both employees with normal hearing and HI. American Academy of Audiology.
Radon and material radiopurity assessment for the NEXT double beta decay experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cebrián, S.; Dafni, T.; González-Díaz, D.
The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in {sup 136}Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes havemore » been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.« less
NASA Astrophysics Data System (ADS)
Johnson, B.; Cullis, P.; Schnell, R. C.; Oltmans, S. J.; Sterling, C. W.; Jordan, A. F.; Hall, E.
2016-12-01
Extreme high ozone mixing ratios, far exceeding U.S. National Air Quality Standards, were observed in the Uinta Basin in January-February 2013 under conditions highly favorable for wintertime ozone production. Hourly average ozone mixing ratios increased from regional background levels of 40-50 ppbv to >160 ppbv during several multi-day episodes of prolonged temperature inversions over snow-covered ground within air confining topography. Extensive surface and tethered balloon profile measurements of ozone, meteorology, CH4, CO2, NO2 and a suite of non-methane hydrocarbons (NMHCs) link emissions from oil and natural gas extraction with the strong ozone production throughout the Basin. High levels of NMHCs that were well correlated with CH4 showed that abundant O3 precursors were available throughout the Basin where high ozone mixing ratios extended from the surface to the top of the inversion layer at 200 m above ground level. This layer was at a nearly uniform height across the Basin even though there are significant terrain variations. Tethered balloon measurements rising above the elevated levels of ozone within the cold pool layer beneath the inversion measured regional background O3 concentrations. Surface wind and direction data from tethered balloons showed a consistent diurnal pattern in the Basin that moved air with the highest levels of CH4 and ozone precursor NMHC's from the gas fields of the east-central portion of the Basin to the edges during the day, before draining back into the Basin at night.
NASA Astrophysics Data System (ADS)
Ammendola, R.; Barbanera, M.; Bizzarri, M.; Bonaiuto, V.; Ceccucci, A.; Checcucci, B.; De Simone, N.; Fantechi, R.; Federici, L.; Fucci, A.; Lupi, M.; Paoluzzi, G.; Papi, A.; Piccini, M.; Ryjov, V.; Salamon, A.; Salina, G.; Sargeni, F.; Venditti, S.
2017-03-01
The NA62 experiment at CERN SPS has started its data-taking. Its aim is to measure the branching ratio of the ultra-rare decay K+ → π+ν ν̅ . In this context, rejecting the background is a crucial topic. One of the main background to the measurement is represented by the K+ → π+π0 decay. In the 1-8.5 mrad decay region this background is rejected by the calorimetric trigger processor (Cal-L0). In this work we present the performance of a soft-core based parallel architecture built on FPGAs for the energy peak reconstruction as an alternative to an implementation completely founded on VHDL language.
Radiation dose in the high background radiation area in Kerala, India.
Christa, E P; Jojo, P J; Vaidyan, V K; Anilkumar, S; Eappen, K P
2012-03-01
A systematic radiological survey has been carried out in the region of high-background radiation area in Kollam district of Kerala to define the natural gamma-radiation levels. One hundred and forty seven soil samples from high-background radiation areas and five samples from normal background region were collected as per standard sampling procedures and were analysed for (238)U, (232)Th and (40)K by gamma-ray spectroscopy. External gamma dose rates at all sampling locations were also measured using a survey meter. The activities of (238)U, (232)Th and (40)K was found to vary from 17 to 3081 Bq kg(-1), 54 to 11976 Bq kg(-1) and BDL (67.4 Bq kg(-1)) to 216 Bq kg(-1), respectively, in the study area. Such heterogeneous distribution of radionuclides in the region may be attributed to the deposition phenomenon of beach sand soil in the region. Radium equivalent activities were found high in several locations. External gamma dose rates estimated from the levels of radionuclides in soil had a range from 49 to 9244 nGy h(-1). The result of gamma dose rate measured at the sampling sites using survey meter showed an excellent correlation with dose rates computed from the natural radionuclides estimated from the soil samples.
NASA Astrophysics Data System (ADS)
Radhakrishnan, Regunathan; Divakaran, Ajay; Xiong, Ziyou; Otsuka, Isao
2006-12-01
We propose a content-adaptive analysis and representation framework to discover events using audio features from "unscripted" multimedia such as sports and surveillance for summarization. The proposed analysis framework performs an inlier/outlier-based temporal segmentation of the content. It is motivated by the observation that "interesting" events in unscripted multimedia occur sparsely in a background of usual or "uninteresting" events. We treat the sequence of low/mid-level features extracted from the audio as a time series and identify subsequences that are outliers. The outlier detection is based on eigenvector analysis of the affinity matrix constructed from statistical models estimated from the subsequences of the time series. We define the confidence measure on each of the detected outliers as the probability that it is an outlier. Then, we establish a relationship between the parameters of the proposed framework and the confidence measure. Furthermore, we use the confidence measure to rank the detected outliers in terms of their departures from the background process. Our experimental results with sequences of low- and mid-level audio features extracted from sports video show that "highlight" events can be extracted effectively as outliers from a background process using the proposed framework. We proceed to show the effectiveness of the proposed framework in bringing out suspicious events from surveillance videos without any a priori knowledge. We show that such temporal segmentation into background and outliers, along with the ranking based on the departure from the background, can be used to generate content summaries of any desired length. Finally, we also show that the proposed framework can be used to systematically select "key audio classes" that are indicative of events of interest in the chosen domain.
Metrics for Good Measure. Level III. Instructor's Guide.
ERIC Educational Resources Information Center
Cooper, Gloria S.; And Others
This guide and the accompanying student workbook (separate document) comprise the Adult Basic Education Level III (grades 7, 8, and 9) package on the metric system. An introductory section provides background information on adult basic daily living skills, a discussion of the design and use of the student workbook, and information on what the…
Metrics for Good Measure. Level II. Instructor's Guide.
ERIC Educational Resources Information Center
Cooper, Gloria S.; And Others
This guide and the accompanying student workbook (separate document) comprise the Adult Basic Education Level II (grades 4, 5, and 6) package on the metric system. An introductory section provides background information on adult basic daily living skills, a discussion of the design and use of the student workbook, and information on what the…
Genetic Influences on Mechanically-Assessed Activity Level in Children
ERIC Educational Resources Information Center
Wood, Alexis C.; Saudino, Kimberly J.; Rogers, Hannah; Asherson, Philip; Kuntsi, Jonna
2007-01-01
Background: Activity level is an important component of children's temperament, as well as being part of the core symptom domain of hyperactivity-impulsivity within attention deficit hyperactivity disorder (ADHD). Yet it is poorly understood, due partly to limitations on parent and teacher ratings, which are typically used as measurements of these…
Work-Family Balance and Energy: A Day-Level Study on Recovery Conditions
ERIC Educational Resources Information Center
Sanz-Vergel, Ana Isabel; Demerouti, Evangelia; Moreno-Jimenez, Bernardo; Mayo, Margarita
2010-01-01
The present study examines whether daily recovery inhibiting and enhancing conditions predict day-levels of work-family conflict (WFC), work-family facilitation (WFF), exhaustion and vigor. Forty-nine individuals from various professional backgrounds in Spain provided questionnaire and daily survey measures over a period of five working days.…
Background Higher ambient fine particulate matter (PM2.5) levels can be associated with increased blood pressure and vascular dysfunction. Objectives To determine the differential effects on blood pressure and vascular function of daily changes in community ambient-...
Environmental Literacy in Teacher Training in Israel: Environmental Behavior of New Students
ERIC Educational Resources Information Center
Goldman, Daphne; Yavetz, Bela; Pe'er, Sara
2006-01-01
The authors measured the level of environmental behavior of new students in 3 major teacher-training colleges in Israel and investigated the relationship between behavior and background factors. Factor analysis of students' responses resulted in grouping of environmental behavior items into 6 categories that represent increasing levels of…
ERIC Educational Resources Information Center
Hannon, Brenda
2015-01-01
This study uncovers which learning (epistemic belief of learning), socioeconomic background (level of parental education, family income) or social-personality factors (performance-avoidance goals, test anxiety) mitigate the ethnic gap in SAT (Scholastic Assessment Test) scores. Measures assessing achievement motivation, test anxiety, socioeconomic…
Classroom Listening Conditions in Indian Primary Schools: A Survey of Four Schools
Sundaravadhanan, Gayathri; Selvarajan, Heramba G.; McPherson, Bradley
2017-01-01
Introduction: Background noise affects the listening environment inside classrooms, especially for younger children. High background noise level adversely affects not only student speech perception but also teacher vocal hygiene. The current study aimed to give an overview of the classroom listening conditions in selected government primary schools in India. Materials and Methods: Noise measurements were taken in 23 classrooms of four government primary schools in southern India, using a type 2 sound level meter. In each classroom measurements were taken in occupied and unoccupied conditions. Teacher voice level was measured in the same classrooms. In addition, the classroom acoustical conditions were observed and the reverberation time for each classroom was calculated. Results: The mean occupied noise level was 62.1 dBA and 65.6 dBC, and the mean unoccupied level was 62.2 dBA and 65 dBC. The mean unamplified teacher speech-to-noise ratio was 10.6 dBA. Both the occupied and unoccupied noise levels exceeded national and international recommended levels and the teacher speech-to-noise ratio was also found to be inadequate in most classrooms. The estimated reverberation time in all classrooms was greater than 2.6 seconds, which is almost double the duration of accepted standards. In addition, observation of classrooms revealed insufficient acoustical treatment to effectively reduce internal and external noise and minimize reverberation. Conclusion: The results of this study point out the need to improve the listening environment for children in government primary schools in India. PMID:28164937
Classroom Listening Conditions in Indian Primary Schools: A Survey of Four Schools.
Sundaravadhanan, Gayathri; Selvarajan, Heramba G; McPherson, Bradley
2017-01-01
Background noise affects the listening environment inside classrooms, especially for younger children. High background noise level adversely affects not only student speech perception but also teacher vocal hygiene. The current study aimed to give an overview of the classroom listening conditions in selected government primary schools in India. Noise measurements were taken in 23 classrooms of four government primary schools in southern India, using a type 2 sound level meter. In each classroom measurements were taken in occupied and unoccupied conditions. Teacher voice level was measured in the same classrooms. In addition, the classroom acoustical conditions were observed and the reverberation time for each classroom was calculated. The mean occupied noise level was 62.1 dBA and 65.6 dBC, and the mean unoccupied level was 62.2 dBA and 65 dBC. The mean unamplified teacher speech-to-noise ratio was 10.6 dBA. Both the occupied and unoccupied noise levels exceeded national and international recommended levels and the teacher speech-to-noise ratio was also found to be inadequate in most classrooms. The estimated reverberation time in all classrooms was greater than 2.6 seconds, which is almost double the duration of accepted standards. In addition, observation of classrooms revealed insufficient acoustical treatment to effectively reduce internal and external noise and minimize reverberation. The results of this study point out the need to improve the listening environment for children in government primary schools in India.
Improved electron probe microanalysis of trace elements in quartz
Donovan, John J.; Lowers, Heather; Rusk, Brian G.
2011-01-01
Quartz occurs in a wide range of geologic environments throughout the Earth's crust. The concentration and distribution of trace elements in quartz provide information such as temperature and other physical conditions of formation. Trace element analyses with modern electron-probe microanalysis (EPMA) instruments can achieve 99% confidence detection of ~100 ppm with fairly minimal effort for many elements in samples of low to moderate average atomic number such as many common oxides and silicates. However, trace element measurements below 100 ppm in many materials are limited, not only by the precision of the background measurement, but also by the accuracy with which background levels are determined. A new "blank" correction algorithm has been developed and tested on both Cameca and JEOL instruments, which applies a quantitative correction to the emitted X-ray intensities during the iteration of the sample matrix correction based on a zero level (or known trace) abundance calibration standard. This iterated blank correction, when combined with improved background fit models, and an "aggregate" intensity calculation utilizing multiple spectrometer intensities in software for greater geometric efficiency, yields a detection limit of 2 to 3 ppm for Ti and 6 to 7 ppm for Al in quartz at 99% t-test confidence with similar levels for absolute accuracy.
Accurate measurements of E2 lifetimes using the coincidence recoil-distance method
NASA Astrophysics Data System (ADS)
Bhalla, R. K.; Poletti, A. R.
1984-05-01
Mean lives of four E2 transitions in the (2s, 1d) shell have been measured using the recoil-distance method (RDM), γ-rays de-exciting the level of interest were detected in coincidence with particles detected in an annular detector at a backward angle thereby reducing the background and producing a beam of recoiling nuclei of well-defined energy and recoil direction. Lifetimes measured were: 22Ne, 1.275 MeV level (2 + → 0 +), 5.16±0.13 ps; 26Mg, 3.588 MeV level (0 + → 2 +), 9.29±0.23 ps; 30Si, 3.788 MeV level (0 +→ 2 +), 12.00±0.70 ps; 38Ar, 3.377 MeV level (0 + → 2 +), 34.5±1.5 ps. The present measurements are compared to those of previous investigators. For the 22Ne level, averaged results from four different measurement techniques are compared and found to be in good agreement. The experimental results are compared to shell-model calculations.
Airborne LIDAR Measurements of Aerosol and Ozone Above the Alberta Oil Sands Region
NASA Astrophysics Data System (ADS)
Aggarwal, M.; Whiteway, J. A.; Seabrook, J.; Gray, L. H.
2014-12-01
Lidar measurements of ozone and aerosol were conducted from a Twin Otter aircraft above the oil sands region of northern Alberta. The field campaign was carried out with a total of five flights out of Fort McMurray, Alberta during the period between August 22 and August 26, 2013. Significant amounts of aerosol were observed within the boundary layer, up to a height of 1.6 km, but the ozone concentration remained at or below background levels. On August 24th the lidar observed a separated layer of aerosol above the boundary layer, at a height of 1.8 km, in which the ozone mixing ratio increased to 70 ppbv. Backward trajectory calculations revealed that the air containing this separated aerosol layer had passed over an area of forest fires. Directly below the layer of forest fire smoke, in the pollution from the oil sands industry, the measured ozone mixing ratio was lower than the background levels (≤35 ppbv).
Zhang, Weihua; Ungar, Kurt; Liu, Chuanlei; Mailhot, Maverick
2016-10-01
A series of measurements have been recently conducted to determine the cosmic-muon intensities and attenuation factors at various indoor and underground locations for a gamma spectrometer. For this purpose, a digital coincidence spectrometer was developed by using two BC408 plastic scintillation detectors and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results indicate that the overburden in the building at surface level absorbs a large part of cosmic ray protons while attenuating the cosmic-muon intensity by 20-50%. The underground facility has the largest overburden of 39 m water equivalent, where the cosmic-muon intensity is reduced by a factor of 6. The study provides a cosmic-muon intensity measurement and overburden assessment, which are important parameters for analysing the background of an HPGe counting system, or for comparing the background of similar systems. Copyright © 2016 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Fahim, Cherine; Stip, Emmanuel; Mancini-Marie, Adham; Beauregard, Mario
2004-01-01
Background: Brain morphology and physiological measures in schizophrenia have yielded inconsistent results. This may be due in part to difficulties in ascertaining precisely to what degree each measure deviates from its genetically and environmentally determined potential level. We attempted to surmount this problem in a paradigm involving…
Acceptance Tests for AMS Radiocarbon Measurements at iThemba LABS, Gauteng, South Africa
NASA Astrophysics Data System (ADS)
Mbele, Vela L.; Mullins, Simon M.; Winkler, Stephan R.; Woodborne, Stephan
The accelerator mass spectrometer was commissioned recently at the iThemba LABS 6 MV tandem accelerator. Improvements in the vacuum system, requiring procurement of cryo-pumps and the reducing the tank pressure of the N2 + CO2 insulation gas mixture below the level used for IBA measurements, were necessary. This resulted in the reduction of the nitrogen background and improved the resolution of 14C from 14N background in the ionisation chamber. The nitrogen was leaking to the stripping canal because of inadequate sealing. The analysing magnet was scaled to detect C3+ ions, at 3 MV terminal potential. The first sensible spectra allowed for the pin-pointing of many persistent issues. This resulted in measurements with a precision better than 1 pMC, and current blank levels correspond to 12 half-lives of 14C or ∼68000 years. The radiocarbon sample preparation laboratory has reached production status. A brief outlook of the work towards the implementation of the measurement and chemical preparation protocols for radionuclides 10Be and 26Al is also summarised in the conclusion
Rönnberg, Niklas; Rudner, Mary; Lunner, Thomas; Stenfelt, Stefan
2014-01-01
Listening in noise is often perceived to be effortful. This is partly because cognitive resources are engaged in separating the target signal from background noise, leaving fewer resources for storage and processing of the content of the message in working memory. The Auditory Inference Span Test (AIST) is designed to assess listening effort by measuring the ability to maintain and process heard information. The aim of this study was to use AIST to investigate the effect of background noise types and signal-to-noise ratio (SNR) on listening effort, as a function of working memory capacity (WMC) and updating ability (UA). The AIST was administered in three types of background noise: steady-state speech-shaped noise, amplitude modulated speech-shaped noise, and unintelligible speech. Three SNRs targeting 90% speech intelligibility or better were used in each of the three noise types, giving nine different conditions. The reading span test assessed WMC, while UA was assessed with the letter memory test. Twenty young adults with normal hearing participated in the study. Results showed that AIST performance was not influenced by noise type at the same intelligibility level, but became worse with worse SNR when background noise was speech-like. Performance on AIST also decreased with increasing memory load level. Correlations between AIST performance and the cognitive measurements suggested that WMC is of more importance for listening when SNRs are worse, while UA is of more importance for listening in easier SNRs. The results indicated that in young adults with normal hearing, the effort involved in listening in noise at high intelligibility levels is independent of the noise type. However, when noise is speech-like and intelligibility decreases, listening effort increases, probably due to extra demands on cognitive resources added by the informational masking created by the speech fragments and vocal sounds in the background noise. PMID:25566159
Rönnberg, Niklas; Rudner, Mary; Lunner, Thomas; Stenfelt, Stefan
2014-01-01
Listening in noise is often perceived to be effortful. This is partly because cognitive resources are engaged in separating the target signal from background noise, leaving fewer resources for storage and processing of the content of the message in working memory. The Auditory Inference Span Test (AIST) is designed to assess listening effort by measuring the ability to maintain and process heard information. The aim of this study was to use AIST to investigate the effect of background noise types and signal-to-noise ratio (SNR) on listening effort, as a function of working memory capacity (WMC) and updating ability (UA). The AIST was administered in three types of background noise: steady-state speech-shaped noise, amplitude modulated speech-shaped noise, and unintelligible speech. Three SNRs targeting 90% speech intelligibility or better were used in each of the three noise types, giving nine different conditions. The reading span test assessed WMC, while UA was assessed with the letter memory test. Twenty young adults with normal hearing participated in the study. Results showed that AIST performance was not influenced by noise type at the same intelligibility level, but became worse with worse SNR when background noise was speech-like. Performance on AIST also decreased with increasing memory load level. Correlations between AIST performance and the cognitive measurements suggested that WMC is of more importance for listening when SNRs are worse, while UA is of more importance for listening in easier SNRs. The results indicated that in young adults with normal hearing, the effort involved in listening in noise at high intelligibility levels is independent of the noise type. However, when noise is speech-like and intelligibility decreases, listening effort increases, probably due to extra demands on cognitive resources added by the informational masking created by the speech fragments and vocal sounds in the background noise.
Dale, Matthew A.; Ruhlman, Melissa K.; Zhao, Shijia; Meisinger, Trevor; Gu, Linxia; Swier, Vicki J.; Agrawal, Devendra K.; Greiner, Timothy C.; Carson, Jeffrey S.; Baxter, B. Timothy; Xiong, Wanfen
2015-01-01
Objective Evidence has demonstrated profound influence of genetic background on cardiovascular phenotypes. Murine models in Marfan syndrome (MFS) have shown that genetic background-related variations affect thoracic aortic aneurysm formation, rupture, and lifespan of mice. MFS mice with C57Bl/6 genetic background are less susceptible to aneurysm formation compared to the 129/SvEv genetic background. In this study, we hypothesize that susceptibility to abdominal aortic aneurysm (AAA) will be increased in 129/SvEv mice versus C57Bl/6 mice. We tested this hypothesis by assessing differences in aneurysm size, tissue properties, immune response, and MMP expression. Methods Mice of C57Bl/6 or 129/SvEv background underwent AAA induction by periaortic application of CaCl2. Baseline aortic diameters, tissue properties and MMP levels were measured. After aneurysm induction, diameters, MMP expression, and immune response (macrophage infiltration and bone marrow transplantation) were measured. Results Aneurysms were larger in 129/SvEv mice than C57Bl/6 mice (83.0% ± 13.6 increase compared to 57.8% ± 6.4). The aorta was stiffer in the 129/SvEv mice compared to C57Bl/6 mice (952.5 kPa ± 93.6 versus 621.4 kPa ± 84.2). Baseline MMP-2 and post-aneurysm MMP-2 and -9 levels were higher in 129/SvEv aortas compared to C57Bl/6 aortas. Elastic lamella disruption/fragmentation and macrophage infiltration were increased in 129/SvEv mice. Myelogenous cell reversal by bone marrow transplantation did not affect aneurysm size. Conclusions These data demonstrate that 129/SvEv mice are more susceptible to AAA compared to C57Bl/6 mice. Intrinsic properties of the aorta between the two strains of mice, including baseline expression of MMP-2, influence susceptibility to AAA. PMID:26546710
Allen, Michael T; Bocek, Christine M; Burch, Ashley E
2011-09-01
The primary aim of this study was to evaluate the relationships of perceived background stress and self-reported psychological distress on cardiovascular reactivity during acute laboratory stressors. The Perceived Stress Scale (PSS) was used as the measure of perceived background stress, and the General Health Questionnaire (GHQ) was used as the measure of psychological distress. A secondary aim was to examine whether background stress and psychological distress affected the susceptibility to induction of a negative mood using music. Heart rate (HR) and blood pressure (BP) were measured in 149 female and male college students at rest and during a stressful mental arithmetic (MA) task and a mood induction procedure. Higher scores on the GHQ were associated with lower systolic BP reactivity during the MA task by all participants. Higher scores on the PSS and GHQ were also associated with lower diastolic BP and HR reactivity, but only in females. Thus, higher self-reports of background stress and psychological distress tended to result in blunted reactivity to an acute laboratory challenge. Higher levels of background stress and psychological distress were not associated with greater susceptibility to a negative mood induction. This study adds to the growing literature indicating that potentially negative health outcomes may be associated with diminished cardiovascular reactivity under certain conditions. Copyright © 2011 Elsevier B.V. All rights reserved.
Rodzi, Mohd; Zhumadilov, Kassym; Ohtaki, Megu; Ivannikov, Alexander; Bhattacharjee, Deborshi; Fukumura, Akifumi; Hoshi, Masaharu
2011-08-01
Background radiation dose is used in dosimetry for estimating occupational doses of radiation workers or determining radiation dose of an individual following accidental exposure. In the present study, the absorbed dose and the background radiation level are determined using the electron spin resonance (ESR) method on tooth samples. The effect of using different tooth surfaces and teeth exposed with single medical X-rays on the absorbed dose are also evaluated. A total of 48 molars of position 6-8 were collected from 13 district hospitals in Peninsular Malaysia. Thirty-six teeth had not been exposed to any excessive radiation, and 12 teeth had been directly exposed to a single X-ray dose during medical treatment prior to extraction. There was no significant effect of tooth surfaces and exposure with single X-rays on the measured absorbed dose of an individual. The mean measured absorbed dose of the population is 34 ± 6.2 mGy, with an average tooth enamel age of 39 years. From the slope of a regression line, the estimated annual background dose for Peninsular Malaysia is 0.6 ± 0.3 mGy y(-1). This value is slightly lower than the yearly background dose for Malaysia, and the radiation background dose is established by ESR tooth measurements on samples from India and Russia.
Microwave SQUID multiplexer demonstration for cosmic microwave background imagers
NASA Astrophysics Data System (ADS)
Dober, B.; Becker, D. T.; Bennett, D. A.; Bryan, S. A.; Duff, S. M.; Gard, J. D.; Hays-Wehle, J. P.; Hilton, G. C.; Hubmayr, J.; Mates, J. A. B.; Reintsema, C. D.; Vale, L. R.; Ullom, J. N.
2017-12-01
Key performance characteristics are demonstrated for the microwave superconducting quantum interference device (SQUID) multiplexer (μmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the μmux produces a white, input referred current noise level of 29 pA/ √{H z } at a microwave probe tone power of -77 dB, which is well below the expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98 pA/ √{H z } in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ˜100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the μmux as a viable readout technique for future CMB imaging instruments.
Airborne detection of diffuse carbon dioxide emissions at Mammoth Mountain, California
Gerlach, T.M.; Doukas, M.P.; McGee, K.A.; Kessler, R.
1999-01-01
We report the first airborne detection of CO2 degassing from diffuse volcanic sources. Airborne measurement of diffuse CO2 degassing offers a rapid alternative for monitoring CO2 emission rates at Mammoth Mountain. CO2 concentrations, temperatures, and barometric pressures were measured at ~2,500 GPS-referenced locations during a one-hour, eleven-orbit survey of air around Mammoth Mountain at ~3 km from the summit and altitudes of 2,895-3,657 m. A volcanic CO2 anomaly 4-5 km across with CO2 levels ~1 ppm above background was revealed downwind of tree-kill areas. It contained a 1-km core with concentrations exceeding background by >3 ppm. Emission rates of ~250 t d-1 are indicated. Orographic winds may play a key role in transporting the diffusely degassed CO2 upslope to elevations where it is lofted into the regional wind system.We report the first airborne detection of CO2 degassing from diffuse volcanic sources. Airborne measurement of diffuse CO2 degassing offers a rapid alternative for monitoring CO2 emission rates at Mammoth Mountain. CO2 concentrations, temperatures, and barometric pressures were measured at approximately 2,500 GPS-referenced locations during a one-hour, eleven-orbit survey of air around Mammoth Mountain at approximately 3 km from the summit and altitudes of 2,895-3,657 m. A volcanic CO2 anomaly 4-5 km across with CO2 levels approximately 1 ppm above background was revealed downwind of tree-kill areas. It contained a 1-km core with concentrations exceeding background by >3 ppm. Emission rates of approximately 250 t d-1 are indicated. Orographic winds may play a key role in transporting the diffusely degassed CO2 upslope to elevations where it is lofted into the regional wind system.
Characteristics of noise-canceling headphones to reduce the hearing hazard for MP3 users.
Liang, Maojin; Zhao, Fei; French, David; Zheng, Yiqing
2012-06-01
Three pairs of headphones [standard iPod ear buds and two noise-canceling headphones (NCHs)] were chosen to investigate frequency characteristics of noise reduction, together with their attenuation effects on preferred listening levels (PLLs) in the presence of various types of background noise. Twenty-six subjects with normal hearing chose their PLLs in quiet, street noise, and subway noise using the three headphones and with the noise-canceling system on/off. Both sets of NCHs reduced noise levels at mid- and high-frequencies. Further noise reductions occurred in low frequencies with the noise canceling system switched on. In street noise, both NCHs had similar noise reduction effects. In subway noise, better noise reduction effects were found in the expensive NCH and with noise-canceling on. A two way repeated measures analysis of variance showed that both listening conditions and headphone styles were significant influencing factors on the PLLs. Subjects tended to increase their PLLs as the background noise level increased. Compared with ear buds, PLLs obtained from NCHs-on in the presence of background noise were reduced up to 4 dB. Therefore, proper selection and use of NCHs appears beneficial in reducing the risk of hearing damage caused by high music listening levels in the presence of background noise.
NASA Astrophysics Data System (ADS)
Guest, P. S.; Persson, O. P. G.; Blomquist, B.; Fairall, C. W.
2016-02-01
"Background" stability refers to the effect of vertical virtual temperature variations above the surface layer on fluxes within the surface layer. This is different from the classical surface layer stability quantified by the Obhukhov length scale. In most locations, changes in the background stability do not have a significant direct impact on surface fluxes. However in polar regions, where there is usually a strong low-level temperature inversion capping the boundary layer, changes in background stability can have big impacts on surface fluxes. Therefore, in the Arctic, there is potential for a positive feedback effect between ice cover and surface wind speed (and momentum flux) due to the background stability effects. As the surface becomes more ice free, heat fluxes from the surface weaken the temperature inversion which in turn increases the surface wind speed which further increases the surface turbulent heat fluxes and removes more sea ice by melting or advection. It is not clear how important feedbacks involving the background stability are during the fall freeze up of the Arctic Ocean; that will be the focus of this study. As part of an ONR-sponsored cruise in the fall of 2015 to examine sea state and boundary layer processes in the Beaufort Sea on the R/V Sikuliaq, the authors will perform a variety of surface layer and upper level atmospheric measurements of temperature, humidity and wind vector using ship platform instruments, radiosonde weather balloons, tethered balloons, kites, and miniature quad-rotor unmanned aerial vehicles. In addition, the authors will deploy a full suite of turbulent and radiational flux measurements from the vessel. These measurements will be used to quantify the impact of changing surface conditions on atmospheric structure and vice-versa. The goal is to directly observe how the surface and atmosphere above the surface layer interact and feedback with each other through radiational and turbulent fluxes.
Radioactivity measurement of radioactive contaminated soil by using a fiber-optic radiation sensor
NASA Astrophysics Data System (ADS)
Joo, Hanyoung; Kim, Rinah; Moon, Joo Hyun
2016-06-01
A fiber-optic radiation sensor (FORS) was developed to measure the gamma radiation from radioactive contaminated soil. The FORS was fabricated using an inorganic scintillator (Lu,Y)2SiO5:Ce (LYSO:Ce), a mixture of epoxy resin and hardener, aluminum foil, and a plastic optical fiber. Before its real application, the FORS was tested to determine if it performed adequately. The test result showed that the measurements by the FORS adequately followed the theoretically estimated values. Then, the FORS was applied to measure the gamma radiation from radioactive contaminated soil. For comparison, a commercial radiation detector was also applied to measure the same soil samples. The measurement data were analyzed by using a statistical parameter, the critical level to determine if net radioactivity statistically different from background was present in the soil sample. The analysis showed that the soil sample had radioactivity distinguishable from background.
Spatio-temporal variation of urban ultrafine particle number concentrations
NASA Astrophysics Data System (ADS)
Ragettli, Martina S.; Ducret-Stich, Regina E.; Foraster, Maria; Morelli, Xavier; Aguilera, Inmaculada; Basagaña, Xavier; Corradi, Elisabetta; Ineichen, Alex; Tsai, Ming-Yi; Probst-Hensch, Nicole; Rivera, Marcela; Slama, Rémy; Künzli, Nino; Phuleria, Harish C.
2014-10-01
Methods are needed to characterize short-term exposure to ultrafine particle number concentrations (UFP) for epidemiological studies on the health effects of traffic-related UFP. Our aims were to assess season-specific spatial variation of short-term (20-min) UFP within the city of Basel, Switzerland, and to develop hybrid models for predicting short-term median and mean UFP levels on sidewalks. We collected measurements of UFP for periods of 20 min (MiniDiSC particle counter) and determined traffic volume along sidewalks at 60 locations across the city, during non-rush hours in three seasons. For each monitoring location, detailed spatial characteristics were locally recorded and potential predictor variables were derived from geographic information systems (GIS). We built multivariate regression models to predict local UFP, using concurrent UFP levels measured at a suburban background station, and combinations of meteorological, temporal, GIS and observed site characteristic variables. For a subset of sites, we assessed the relationship between UFP measured on the sidewalk and at the nearby residence (i.e., home outdoor exposure on e.g. balconies). The average median 20-min UFP levels at street and urban background sites were 14,700 ± 9100 particles cm-3 and 9900 ± 8600 particles cm-3, respectively, with the highest levels occurring in winter and the lowest in summer. The most important predictor for all models was the suburban background UFP concentration, explaining 50% and 38% of the variability of the median and mean, respectively. While the models with GIS-derived variables (R2 = 0.61) or observed site characteristics (R2 = 0.63) predicted median UFP levels equally well, mean UFP predictions using only site characteristic variables (R2 = 0.62) showed a better fit than models using only GIS variables (R2 = 0.55). The best model performance was obtained by using a combination of GIS-derived variables and locally observed site characteristics (median: R2 = 0.66; mean: R2 = 0.65). The 20-min UFP concentrations measured at the sidewalk were strongly related (R2 = 0.8) to the concurrent 20-min residential UFP levels nearby. Our results indicate that median UFP can be moderately predicted by means of a suburban background site and GIS-derived traffic and land use variables. In areas and regions where large-scale GIS data are not available, the spatial distribution of traffic-related UFP may be assessed reasonably well by collecting on-site short-term traffic and land-use data.
Report to the National Park Service for Permit LAKE-2014-SCI-002
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnley, Pamela C.
The overall purpose of the study is to determine how to use existing geologic data to predict gamma-ray background levels as measured during aerial radiological surveys. Aerial radiological surveys have typically been for resource exploration purposes but are now also used for homeland security purposes and nuclear disaster assessment as well as determining the depth of snowpack. Foreknowledge of the background measured during aerial radiological survey will be valuable for all the above applications. The gamma-ray background comes from the rocks and soil within the first 30 cm of the earth’s surface in the area where the survey is beingmore » made. The background should therefore be predictable based on an understanding of the distribution and geochemistry of the rocks on the surface. We are using a combination of geologic maps, remote sensing imagery and geochemical data from existing databases and the scientific literature to develop a method for predicting gamma-ray backgrounds. As part of this project we have an opportunity to ground truth our technique along a survey calibration line near Lake Mojave that is used by the Remote Sensing Lab (RSL) of National Security Technologies, LLC (NSTec). RSL makes aerial measurements along this line on a regular basis, so the aerial background in the area is well known. By making ground-based measurements of the gamma-ray background and detailed observations of the geology of the ground surface as well as local topography we will have the data we need to make corrections to the models we build based on the remote sensing and geologic data. Our project involves collaborators from the Airborne Geophysics Section of the Geological Survey of Canada as well as from NSTec’s RSL. Findings« less
Measuring healthcare productivity - from unit to system level.
Kämäräinen, Vesa Johannes; Peltokorpi, Antti; Torkki, Paulus; Tallbacka, Kaj
2016-04-18
Purpose - Healthcare productivity is a growing issue in most Western countries where healthcare expenditure is rapidly increasing. Therefore, accurate productivity metrics are essential to avoid sub-optimization within a healthcare system. The purpose of this paper is to focus on healthcare production system productivity measurement. Design/methodology/approach - Traditionally, healthcare productivity has been studied and measured independently at the unit, organization and system level. Suggesting that productivity measurement should be done in different levels, while simultaneously linking productivity measurement to incentives, this study presents the challenges of productivity measurement at the different levels. The study introduces different methods to measure productivity in healthcare. In addition, it provides background information on the methods used to measure productivity and the parameters used in these methods. A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical information for managers. Findings - The study introduces different approaches and methods to measure productivity in healthcare. Practical implications - A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical benefits for managers. Originality/value - The authors focus on the measurement of the whole healthcare production system and try to avoid sub-optimization. Additionally considering an individual patient approach, productivity measurement is examined at the unit level, the organizational level and the system level.
Background levels in the Borexino detector
NASA Astrophysics Data System (ADS)
D'Angelo, Davide; Wurm, Michael; Borexino Collaboration
2008-11-01
The Borexino detector, designed and constructed for sub-MeV solar neutrino spectroscopy, is taking data at the Gran Sasso Laboratory, Italy; since May 2007. The main physics objective of Borexino, based on elastic scattering of neutrinos in organic liquid scintillator, is the real time flux measurement of the 862keV mono-energetic neutrinos from 7Be, which set extremely severe radio-purity requirements in the detector's design and handling. The first year of continous data taking provide now evidence of the extremely low background levels achieved in the construction of the detector and in the purification of the target mass. Several pieces of analysis sense the presence of radioisotopes of the 238U and 232Th chains, of 85Kr and of 210Po out of equilibrium from other Radon daughters. Particular emphasis is given to the detection of the cosmic muon background whose angular distributions have been obtained with the outer detector tracking algorithm and to the possibility of tagging the muon-induced neutron background in the scintillator with the recently enhanced electronics setup.
Pratchett, M S; Pisapia, C; Sheppard, C R C
2013-05-01
This study quantified background rates of mortality for Acropora cytherea in the Chagos Archipelago. Despite low levels of anthropogenic disturbance, 27.5% (149/541) of A. cytherea colonies exhibited some level of partial mortality, and 9.0% (49/541) of colonies had recent injuries. A total of 15.3% of the overall surface area of physically intact A. cytherea colonies was dead. Observed mortality was partly attributable to overtopping and/or self-shading among colonies. There were also low-densities of Acanthaster planci apparent at some study sites. However, most of the recent mortality recorded was associated with isolated infestations of the coral crab, Cymo melanodactylus. A. cytherea is a relatively fast growing coral and these levels of mortality may be biologically unimportant. However, few studies have measured background rates of coral mortality, especially in the absence of direct human disturbances. These data are important for assessing the impacts of increasing disturbances, especially in projecting likely recovery. Copyright © 2013. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alarcon, Ricardo; Balascuta, S.; Benson, Stephen V.
2013-11-01
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that needmore » to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW continuous-wave (CW) beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, multipactoring inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation when the machine is tuned for 130 MeV operation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, Jeter C.; Aalseth, Craig E.; Bonicalzi, Ricco
Age dating groundwater and seawater using 39Ar/Ar ratios is an important tool to understand water mass flow rates and mean residence time. For modern or contemporary argon, the 39Ar activity is 1.8 mBq per liter of argon. Radiation measurements at these activity levels require ultra low-background detectors. Low-background proportional counters have been developed at Pacific Northwest National Laboratory. These detectors use traditional mixtures of argon and methane as counting gas, and the residual 39Ar from commercial argon has become a predominant source of background activity in these detectors. We demonstrated sensitivity to 39Ar by using geological or ancient argon frommore » gas wells in place of commercial argon. The low level counting performance of these proportional counters is then demonstrated for sensitivities to 39Ar/Ar ratios sufficient to date water masses as old as 1000 years.« less
NASA Technical Reports Server (NTRS)
Booth, Earl R., Jr.; Henderson, Brenda S.
2005-01-01
The NASA Langley Research Center Low Speed Aeroacoustic Wind Tunnel is a premier facility for model-scale testing of jet noise reduction concepts at realistic flow conditions. However, flow inside the open jet test section is less than optimum. A Construction of Facilities project, scheduled for FY 05, will replace the flow collector with a new design intended to reduce recirculation in the open jet test section. The reduction of recirculation will reduce background noise levels measured by a microphone array impinged by the recirculation flow and will improve flow characteristics in the open jet tunnel flow. In order to assess the degree to which this modification is successful, background noise levels and tunnel flow are documented, in order to establish a baseline, in this report.
Radioactive contamination of scintillators
NASA Astrophysics Data System (ADS)
Danevich, F. A.; Tretyak, V. I.
2018-03-01
Low counting experiments (search for double β decay and dark matter particles, measurements of neutrino fluxes from different sources, search for hypothetical nuclear and subnuclear processes, low background α, β, γ spectrometry) require extremely low background of a detector. Scintillators are widely used to search for rare events both as conventional scintillation detectors and as cryogenic scintillating bolometers. Radioactive contamination of a scintillation material plays a key role to reach low level of background. Origin and nature of radioactive contamination of scintillators, experimental methods and results are reviewed. A programme to develop radiopure crystal scintillators for low counting experiments is discussed briefly.
Effects of pedagogical ideology on the perceived loudness and noise levels in preschools
Jonsdottir, Valdis; Rantala, Leena M.; Oskarsson, Gudmundur Kr.; Sala, Eeva
2015-01-01
High activity noise levels that result in detrimental effects on speech communication have been measured in preschools. To find out if different pedagogical ideologies affect the perceived loudness and levels of noise, a questionnaire study inquiring about the experience of loudness and voice symptoms was carried out in Iceland in eight private preschools, called “Hjalli model”, and in six public preschools. Noise levels were also measured in the preschools. Background variables (stress level, age, length of working career, education, smoking, and number of children per teacher) were also analyzed in order to determine how much they contributed toward voice symptoms and the experience of noisiness. Results indicate that pedagogical ideology is a significant factor for predicting noise and its consequences. Teachers in the preschool with tighter pedagogical control of discipline (the “Hjalli model”) experienced lower activity noise loudness than teachers in the preschool with a more relaxed control of behavior (public preschool). Lower noise levels were also measured in the “Hjalli model” preschool and fewer “Hjalli model” teachers reported voice symptoms. Public preschool teachers experienced more stress than “Hjalli model” teachers and the stress level was, indeed, the background variable that best explained the voice symptoms and the teacher's perception of a noisy environment. Discipline, structure, and organization in the type of activity predicted the activity noise level better than the number of children in the group. Results indicate that pedagogical ideology is a significant factor for predicting self-reported noise and its consequences. PMID:26356370
Intertester reliability of the acceptable noise level.
Gordon-Hickey, Susan; Adams, Elizabeth; Moore, Robert; Gaal, Ashley; Berry, Katie; Brock, Sommer
2012-01-01
The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background noise. Measurement of ANL relies on the tester and listener to follow the instructions set forth. To date, no research has explored the reliability of ANL as measured across clinicians or testers. To examine the intertester reliability of ANL. A descriptive quasi-experimental reliability study was completed. ANL was measured for one group of listeners by three testers. Three participants served as testers. Each tester was familiar with basic audiometry. Twenty-five young adults with normal hearing served as listeners. Each tester was stationed in a laboratory with the needed equipment. Listeners were instructed to report to these laboratories in a random order provided by the experimenters. The testers assessed most comfortable listening level (MCL) and background noise level (BNL) for all 25 listeners. Intraclass correlation coefficients were significant and revealed that MCL, BNL, and ANLs are reliable across testers. Additionally, one-way ANOVAs for MCL, BNL, and ANL were not significant. These findings indicate that MCL, BNL, and ANL do not differ significantly when measured by different testers. If the ANL instruction set is accurately followed, ANL can be reliably measured across testers, laboratories, and clinics. Intertester reliability of ANL allows for comparison across ANLs measured by different individuals. Findings of the present study indicate that tester reliability can be ruled out as a factor contributing to the disparity of mean ANLs reported in the literature. American Academy of Audiology.
An exploratory survey of noise levels associated with a 100kW wind turbine
NASA Technical Reports Server (NTRS)
Balombin, J. R.
1980-01-01
Noise measurements of a 125-foot diameter, 100 kW wind turbine are presented. The data include measurements as functions of distance from the turbine and directivity angle and cover a frequency range from 1 Hz to several kHz. Potential community impact is discussed in terms of A-weighted noise levels relative to background levels, and the intrasonic spectral content. Finally, the change in the sound power spectrum associated with a change in the rotor speed in described. The acoustic impact of this size wind turbine is judged to be minimal.
Fluorometric procedures for dye tracing
Wilson, James F.; Cobb, Ernest D.; Kilpatrick, F.A.
1986-01-01
This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.
Fluorometric procedures for dye tracing
Wilson, James F.
1968-01-01
This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The advantages of dye tracing are (1) low detection and measurement limits and (2) simplicity and accuracy in measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section on aerial photography is included because of its possible use to supplement ground-level fluorometry.
Fluorometric procedures for dye tracing
Wilson, James E.; Cobb, Ernest D.; Kilpatrick, Frederick A.
1984-01-01
This manual describes the current fluorometric procedures used by the U.S. Geological Survey in dye tracer studies such as time of travel, dispersion, reaeration, and dilution-type discharge measurements. The outstanding characteristics of dye tracing are: (1) the low detection and measurement limits, and (2) the simplicity and accuracy of measuring dye tracer concentrations using fluorometric techniques. The manual contains necessary background information about fluorescence, dyes, and fluorometers and a description of fluorometric operation and calibration procedures as a general guide for laboratory and field use. The background information should be useful to anyone wishing to experiment with dyes, fluorometer components, or procedures different from those described. In addition, a brief section is included on aerial photography because of its possible use to supplement ground-level fluorometry.
Wind shear measuring on board an airliner
NASA Technical Reports Server (NTRS)
Krauspe, P.
1984-01-01
A measurement technique which continuously determines the wind vector on board an airliner during takeoff and landing is introduced. Its implementation is intended to deliver sufficient statistical background concerning low frequency wind changes in the atmospheric boundary layer and extended knowledge about deterministic wind shear modeling. The wind measurement scheme is described and the adaptation of apparatus onboard an A300 airbus is shown. Preliminary measurements made during level flight demonstrate the validity of the method.
ERIC Educational Resources Information Center
Blosnich, John; Bossarte, Robert
2011-01-01
Background: Low-level violent behavior, particularly school bullying, remains a critical public health issue that has been associated with negative mental and physical health outcomes. School-based prevention programs, while a valuable line of defense to stave off bullying, have shown inconsistent results in terms of decreasing bullying. This…
Obelix, a new low-background HPGe at Modane Underground Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loaiza, P.; LAL, Univ. Paris-Sud, CNRS/IN2P3, 91405 Orsay; Brudanin, V.
An ultra-low background coaxial HPGe detector for gamma-ray spectrometry with a relative efficiency of 160%, corresponding to a 600 cm{sup 3} Ge crystal, was installed at the Laboratoire Souterrain de Modane, France (4800 m.w.e). To reduce the instrinsic detector background, all parts involved in the detector cryostat were selected for their low radioactivity contamination. A shielding, composed of an inner layer of roman lead and an external layer of regular lead was installed, together with a system to reduce the Rn level inside the sample chamber. The shielding was designed to allow the measurement of Marinelli-shaped samples. We present the constructional detailsmore » which lead to a remarkable low detector background of 73 cts/kg·d in [40, 3000] keV. Measured samples showed that sensitivities about 100 μBq/kg in {sup 226}Ra and {sup 228}Th are reached for samples of some kg and 30 days of lifetime.« less
NASA Technical Reports Server (NTRS)
Bendura, R. J.; Crumbly, K. H.
1977-01-01
Surface-level exhaust effluent measurements of HCl, CO, and particulates, ground-cloud behavior, and some comparisons with model predictions for the launch of a Titan 3 rocket are presented along with a limited amount of airborne sampling measurements of other cloud species (O3, NO, NOX). Values above background levels for these effluents were obtained at 20 of the 30 instrument sites; these values were lower than model predictions and did not exceed public health standards. Cloud rise rate, stabilization altitude, and volume are compared with results from previous launches.
NASA Technical Reports Server (NTRS)
Prosser, William H.; Madaras, Eric I.
2011-01-01
As a next step in the development and implementation of an on-board leak detection and localization system on the International Space Station (ISS), there is a documented need to obtain measurements of the ultrasonic background noise levels that exist within the ISS. This need is documented in the ISS Integrated Risk Management System (IRMA), Watch Item #4669. To address this, scientists and engineers from the Langley Research Center (LaRC) and the Johnson Space Center (JSC), proposed to the NASA Engineering and Safety Center (NESC) and the ISS Vehicle Office a joint assessment to develop a flight package as a Station Development Test Objective (SDTO) that would perform ultrasonic background noise measurements within the United States (US) controlled ISS structure. This document contains the results of the assessment
Development of a multidimensional gamma-spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnett, Jonathan L.; Cantaloub, Michael G.; Mayer, Michael F.
2017-02-28
A high-sensitivity multidimensional gamma-spectrometer is being developed within the shallow underground laboratory at Pacific Northwest National Laboratory (PNNL, USA). The system consists of two Broad Energy Germanium (BEGe) detectors, inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, with reductions in the cosmic background by 49.6% and Compton suppression of 6.5%. For selected radionuclides this provides an overall MDA improvement of 52.7%. Utilizing both detectors for simultaneous measurements of thermally irradiated highly enriched uranium (HEU) increased peak identification and reduced uncertaintymore » by 27.6%. The design uses commercially off-the-shelf (COTS) components, for which the configuration is described, to provide a practical and powerful solution for low-level nuclear measurements.« less
Noise propagation in urban and industrial areas
NASA Technical Reports Server (NTRS)
Davies, H. G.
1976-01-01
Noise propagation in streets and the discrepancies between theoretical analyses and field measurements are discussed. A cell-model is used to estimate the general background level of noise due to vehicular sources distributed over the urban area.
Reference levels of background radioactivity for beach sands and soils in İnebolu/Kastamonu-Turkey
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnaz, Aslı, E-mail: akurnaz@kastamonu.edu.tr; Türkdoğan, Savaş, E-mail: savas-turk-dogan@hotmail.com; Hançerlioğulları, Aybaba, E-mail: aybaba@kastamonu.edu.tr
This paper presents the measurement results of environmental radioactivity levels for İnebolu district (tourist area), Kastamonu-Turkey. The radioactivity concentrations of {sup 238}U, {sup 232}Th, {sup 40}K and the fission product {sup 137}Cs in soil samples collected from 13 region surroundings of study area and in 12 beach sand samples collected from along the coast of İnebolu were determined. To evaluate the radiological hazard of the natural radioactivity, based on the measured concentrations of these radionuclides, the mean absorbed gamma dose and the annual effective dose were evaluated separately, and found to be 112.90 nGy h-1 and 138.46 µSv y-1 for soilmore » samples and 75.19 nGy h-1 and 92.22 µSv y-1 for beach sand samples, respectively. The results show that İnebolu does not have high background.« less
Janovics, R; Kelemen, D I; Kern, Z; Kapitány, S; Veres, M; Jull, A J T; Molnár, M
2016-03-01
Tree ring series were collected from the vicinity of a Hungarian radioactive waste treatment and disposal facility and from a distant control background site, which is not influenced by the radiocarbon discharge of the disposal facility but it represents the natural regional (14)C level. The (14)C concentration of the cellulose content of tree rings was measured by AMS. Data of the tree ring series from the disposal facility was compared to the control site for each year. The results were also compared to the (14)C data of the atmospheric (14)C monitoring stations at the disposal facility and to international background measurements. On the basis of the results, the excess radiocarbon of the disposal facility can unambiguously be detected in the tree from the repository site. Copyright © 2016 Elsevier Ltd. All rights reserved.
Reference levels of background radioactivity for beach sands and soils in İnebolu/Kastamonu-Turkey
NASA Astrophysics Data System (ADS)
Kurnaz, Aslı; Türkdoǧan, Savaş; Hançerlioǧulları, Aybaba; ćetiner, M. Atıf
2016-03-01
This paper presents the measurement results of environmental radioactivity levels for İnebolu district (tourist area), Kastamonu-Turkey. The radioactivity concentrations of 238U, 232Th, 40K and the fission product 137Cs in soil samples collected from 13 region surroundings of study area and in 12 beach sand samples collected from along the coast of İnebolu were determined. To evaluate the radiological hazard of the natural radioactivity, based on the measured concentrations of these radionuclides, the mean absorbed gamma dose and the annual effective dose were evaluated separately, and found to be 112.90 nGy h-1 and 138.46 µSv y-1 for soil samples and 75.19 nGy h-1 and 92.22 µSv y-1 for beach sand samples, respectively. The results show that İnebolu does not have high background.
Najafi Ghezeljeh, Tahereh; Mohades Ardebili, Fatimah; Rafii, Forough; Haghani, Hamid
2016-01-01
This study aimed to investigate the effect of music on the background pain, anxiety, and relaxation levels in burn patients. In this pretest-posttest randomized controlled clinical trial, 100 hospitalized burn patients were selected through convenience sampling. Subjects randomly assigned to music and control groups. Data related to demographic and clinical characteristics, analgesics, and physiologic measures were collected by researcher-made tools. Visual analog scale was used to determine pain, anxiety, and relaxation levels before and after the intervention in 3 consecutive days. Patients' preferred music was offered once a day for 3 days. The control group only received routine care. Data were analyzed using SPSS-PC (V. 20.0). According to paired t-test, there were significant differences between mean scores of pain (P < .001), anxiety (P < .001), and relaxation (P < .001) levels before and after intervention in music group. Independent t-test indicated a significant difference between the mean scores of changes in pain, anxiety, and relaxation levels before and after intervention in music and control groups (P < .001). No differences were detected in the mean scores of physiologic measures between groups before and after music intervention. Music is an inexpensive, appropriate, and safe intervention for applying to burn patients with background pain and anxiety at rest. To produce more effective comfort for patients, it is necessary to compare different types and time lengths of music intervention to find the best approach.
Donnelly, Aoife; Misstear, Bruce; Broderick, Brian
2011-02-15
Background concentrations of nitrogen dioxide (NO(2)) are not constant but vary temporally and spatially. The current paper presents a powerful tool for the quantification of the effects of wind direction and wind speed on background NO(2) concentrations, particularly in cases where monitoring data are limited. In contrast to previous studies which applied similar methods to sites directly affected by local pollution sources, the current study focuses on background sites with the aim of improving methods for predicting background concentrations adopted in air quality modelling studies. The relationship between measured NO(2) concentration in air at three such sites in Ireland and locally measured wind direction has been quantified using nonparametric regression methods. The major aim was to analyse a method for quantifying the effects of local wind direction on background levels of NO(2) in Ireland. The method was expanded to include wind speed as an added predictor variable. A Gaussian kernel function is used in the analysis and circular statistics employed for the wind direction variable. Wind direction and wind speed were both found to have a statistically significant effect on background levels of NO(2) at all three sites. Frequently environmental impact assessments are based on short term baseline monitoring producing a limited dataset. The presented non-parametric regression methods, in contrast to the frequently used methods such as binning of the data, allow concentrations for missing data pairs to be estimated and distinction between spurious and true peaks in concentrations to be made. The methods were found to provide a realistic estimation of long term concentration variation with wind direction and speed, even for cases where the data set is limited. Accurate identification of the actual variation at each location and causative factors could be made, thus supporting the improved definition of background concentrations for use in air quality modelling studies. Copyright © 2010 Elsevier B.V. All rights reserved.
Examining the Validity of Self-Reports on Scales Measuring Students' Strategic Processing
ERIC Educational Resources Information Center
Samuelstuen, Marit S.; Braten, Ivar
2007-01-01
Background: Self-report inventories trying to measure strategic processing at a global level have been much used in both basic and applied research. However, the validity of global strategy scores is open to question because such inventories assess strategy perceptions outside the context of specific task performance. Aims: The primary aim was to…
ERIC Educational Resources Information Center
Woodard, Cooper
2009-01-01
Background: The Assessment Scale for Positive Character Traits-Developmental Disabilities (ASPeCT-DD) was designed to measure the presence and strength of selected positive or strength-based traits in persons with developmental disabilities. These traits may help to determine level of happiness or value associated with the more commonly measured…
Insights from two industrial hygiene pilot e-cigarette passive vaping studies.
Maloney, John C; Thompson, Michael K; Oldham, Michael J; Stiff, Charles L; Lilly, Patrick D; Patskan, George J; Shafer, Kenneth H; Sarkar, Mohamadi A
2016-01-01
While several reports have been published using research methods of estimating exposure risk to e-cigarette vapors in nonusers, only two have directly measured indoor air concentrations from vaping using validated industrial hygiene sampling methodology. Our first study was designed to measure indoor air concentrations of nicotine, menthol, propylene glycol, glycerol, and total particulates during the use of multiple e-cigarettes in a well-characterized room over a period of time. Our second study was a repeat of the first study, and it also evaluated levels of formaldehyde. Measurements were collected using active sampling, near real-time and direct measurement techniques. Air sampling incorporated industrial hygiene sampling methodology using analytical methods established by the National Institute of Occupational Safety and Health and the Occupational Safety and Health Administration. Active samples were collected over a 12-hr period, for 4 days. Background measurements were taken in the same room the day before and the day after vaping. Panelists (n = 185 Study 1; n = 145 Study 2) used menthol and non-menthol MarkTen prototype e-cigarettes. Vaping sessions (six, 1-hr) included 3 prototypes, with total number of puffs ranging from 36-216 per session. Results of the active samples were below the limit of quantitation of the analytical methods. Near real-time data were below the lowest concentration on the established calibration curves. Data from this study indicate that the majority of chemical constituents sampled were below quantifiable levels. Formaldehyde was detected at consistent levels during all sampling periods. These two studies found that indoor vaping of MarkTen prototype e-cigarette does not produce chemical constituents at quantifiable levels or background levels using standard industrial hygiene collection techniques and analytical methods.
Scatolini, Fabio; Alves, Cláudio Jorge Pinto
2016-12-22
To perform a quantitative analysis of the background noise at Congonhas Airport surroundings based on large sampling and measurements with no interruption. Measuring sites were chosen from 62 and 72 DNL (day-night-level) noise contours, in urban sites compatible with residential use. Fifteen sites were monitored for at least 168 hours without interruption or seven consecutive days. Data compilation was based on cross-reference between noise measurements and air traffic control records, and results were validated by airport meteorological reports. Preliminary diagnoses were established using the standard NBR-13368. Background noise values were calculated based on the Sound Exposure Level (SEL). Statistic parameters were calculated in one-hour intervals. Only four of the fifteen sites assessed presented aircraft operations as a clear cause for the noise annoyance. Even so, it is possible to detect background noise levels above regulation limits during periods of low airport activity or when it closes at night. All the sites monitored showed background noise levels above regulation limits between 7:00 and 21:00. In the intervals between 6:00-6:59 and 21:00-22:59 the noise data, when analyzed with the current airport operational characteristics, still allow the development of additional mitigating measures. Avaliar quantitativamente o ruído de fundo no entorno do aeroporto de Congonhas, com base em ampla amostragem e medições sem interrupção. Locais de medição escolhidos a partir de curvas de ruído de 62 e 72 LDN (day-night level), em equipamentos urbanos de uso compatível com o residencial. Quinze locais foram avaliados por mais de 168 horas consecutivas cada um (sete dias). A compilação baseou-se em cruzamentos de dados do controle de tráfego aéreo e os resultados foram validados por meio de relatórios meteorológicos do aeroporto. Diagnósticos preliminares foram estabelecidos utilizando a NBR-13368. O ruído de fundo foi calculado com base no Sound Exposure Level (SEL). Os parâmetros estatísticos foram calculados em intervalos de uma hora. Apenas quatro dos 15 locais avaliados apresentaram clara contribuição da operação de aeronaves no incômodo. Mesmo assim, é possível identificar ruído de fundo acima do regulamentar durante os períodos de baixa atividade ou de fechamento do aeroporto durante a noite. Todos os locais avaliados apresentaram ruído de fundo acima do regulamentar entre 7:00h e 21:00h. Nos intervalos entre 6:00h-6:59h e 21:00h-22:59h, os dados de monitoramento, quando analisados em conjunto com as atuais características operacionais do aeroporto, ainda possibilitam a elaboração de medidas mitigadoras adicionais.
NASA Astrophysics Data System (ADS)
Han, Guang; Liu, Jin; Liu, Rong; Xu, Kexin
2016-10-01
Position-based reference measurement method is taken as one of the most promising method in non-invasive measurement of blood glucose based on spectroscopic methodology. Selecting an appropriate source-detector separation as the reference position is important for deducting the influence of background change and reducing the loss of useful signals. Our group proposed a special source-detector separation named floating-reference position where the signal contains only background change, that is to say, the signal at this source-detector separation is uncorrelated with glucose concentration. The existence of floating-reference position has been verified in a three layer skin by Monte Carlo simulation and in the in vitro experiment. But it is difficult to verify the existence of floating-reference position on the human body because the interference is more complex during in vivo experiment. Aiming at this situation, this paper studies the determination of the best reference position on human body by collecting signals at several source-detector separations on the palm and measuring the true blood glucose levels during oral glucose tolerance test (OGTT) experiments of 3 volunteers. Partial least square (PLS) calibration model is established between the signals at every source-detector separation and its corresponding blood glucose levels. The results shows that the correlation coefficient (R) between 1.32 mm to 1.88 mm is lowest and they can be used as reference for background correction. The signal of this special position is important for improving the accuracy of near-infrared non-invasive blood glucose measurement.
Modeling background radiation using geochemical data: A case study in and around Cameron, Arizona.
Marsac, Kara E; Burnley, Pamela C; Adcock, Christopher T; Haber, Daniel A; Malchow, Russell L; Hausrath, Elisabeth M
2016-12-01
This study compares high resolution forward models of natural gamma-ray background with that measured by high resolution aerial gamma-ray surveys. The ability to predict variations in natural background radiation levels should prove useful for those engaged in measuring anthropogenic contributions to background radiation for the purpose of emergency response and homeland security operations. The forward models are based on geologic maps and remote sensing multi-spectral imagery combined with two different sources of data: 1) bedrock geochemical data (uranium, potassium and thorium concentrations) collected from national databases, the scientific literature and private companies, and 2) the low spatial resolution NURE (National Uranium Resource Evaluation) aerial gamma-ray survey. The study area near Cameron, Arizona, is located in an arid region with minimal vegetation and, due to the presence of abandoned uranium mines, was the subject of a previous high resolution gamma-ray survey. We found that, in general, geologic map units form a good basis for predicting the geographic distribution of the gamma-ray background. Predictions of background gamma-radiation levels based on bedrock geochemical analyses were not as successful as those based on the NURE aerial survey data sorted by geologic unit. The less successful result of the bedrock geochemical model is most likely due to a number of factors including the need to take into account the evolution of soil geochemistry during chemical weathering and the influence of aeolian addition. Refinements to the forward models were made using ASTER visualizations to create subunits of similar exposure rate within the Chinle Formation, which contains multiple lithologies and by grouping alluvial units by drainage basin rather than age. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Modeling background radiation using geochemical data: A case study in and around Cameron, Arizona
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsac, Kara E.; Burnley, Pamela C.; Adcock, Christopher T.
Here, this study compares high-resolution forward models of natural gamma-ray background with that measured by high resolution aerial gamma-ray surveys. The ability to predict variations in natural background radiation levels should prove useful for those engaged in measuring anthropogenic contributions to background radiation for the purpose of emergency response and homeland security operations. The forward models are based on geologic maps and remote sensing multi-spectral imagery combined with two different sources of data: 1) bedrock geochemical data (uranium, potassium and thorium concentrations) collected from national databases, the scientific literature and private companies, and 2) the low spatial resolution NURE (Nationalmore » Uranium Resource Evaluation) aerial gamma-ray survey. The study area near Cameron, Arizona, is located in an arid region with minimal vegetation and, due to the presence of abandoned uranium mines, was the subject of a previous high resolution gamma-ray survey. We found that, in general, geologic map units form a good basis for predicting the geographic distribution of the gamma-ray background. Predictions of background gamma-radiation levels based on bedrock geochemical analyses were not as successful as those based on the NURE aerial survey data sorted by geologic unit. The less successful result of the bedrock geochemical model is most likely due to a number of factors including the need to take into account the evolution of soil geochemistry during chemical weathering and the influence of aeolian addition. Refinements to the forward models were made using ASTER visualizations to create subunits of similar exposure rate within the Chinle Formation, which contains multiple lithologies and by grouping alluvial units by drainage basin rather than age.« less
Modeling background radiation using geochemical data: A case study in and around Cameron, Arizona
Marsac, Kara E.; Burnley, Pamela C.; Adcock, Christopher T.; ...
2016-09-16
Here, this study compares high-resolution forward models of natural gamma-ray background with that measured by high resolution aerial gamma-ray surveys. The ability to predict variations in natural background radiation levels should prove useful for those engaged in measuring anthropogenic contributions to background radiation for the purpose of emergency response and homeland security operations. The forward models are based on geologic maps and remote sensing multi-spectral imagery combined with two different sources of data: 1) bedrock geochemical data (uranium, potassium and thorium concentrations) collected from national databases, the scientific literature and private companies, and 2) the low spatial resolution NURE (Nationalmore » Uranium Resource Evaluation) aerial gamma-ray survey. The study area near Cameron, Arizona, is located in an arid region with minimal vegetation and, due to the presence of abandoned uranium mines, was the subject of a previous high resolution gamma-ray survey. We found that, in general, geologic map units form a good basis for predicting the geographic distribution of the gamma-ray background. Predictions of background gamma-radiation levels based on bedrock geochemical analyses were not as successful as those based on the NURE aerial survey data sorted by geologic unit. The less successful result of the bedrock geochemical model is most likely due to a number of factors including the need to take into account the evolution of soil geochemistry during chemical weathering and the influence of aeolian addition. Refinements to the forward models were made using ASTER visualizations to create subunits of similar exposure rate within the Chinle Formation, which contains multiple lithologies and by grouping alluvial units by drainage basin rather than age.« less
Improving the limits of detection of low background alpha emission measurements
NASA Astrophysics Data System (ADS)
McNally, Brendan D.; Coleman, Stuart; Harris, Jack T.; Warburton, William K.
2018-01-01
Alpha particle emission - even at extremely low levels - is a significant issue in the search for rare events (e.g., double beta decay, dark matter detection). Traditional measurement techniques require long counting times to measure low sample rates in the presence of much larger instrumental backgrounds. To address this, a commercially available instrument developed by XIA uses pulse shape analysis to discriminate alpha emissions produced by the sample from those produced by other surfaces of the instrument itself. Experience with this system has uncovered two residual sources of background: cosmogenics and radon emanation from internal components. An R&D program is underway to enhance the system and extend the pulse shape analysis technique further, so that these residual sources can be identified and rejected as well. In this paper, we review the theory of operation and pulse shape analysis techniques used in XIA's alpha counter, and briefly explore data suggesting the origin of the residual background terms. We will then present our approach to enhance the system's ability to identify and reject these terms. Finally, we will describe a prototype system that incorporates our concepts and demonstrates their feasibility.
Upper limit on the inner radiation belt MeV electron intensity
NASA Astrophysics Data System (ADS)
Li, X.; Selesnick, R. S.; Baker, D. N.; Jaynes, A. N.; Kanekal, S. G.; Schiller, Q.; Blum, L.; Fennell, J.; Blake, J. B.
2015-02-01
No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt.
Das, Sudeep; Sherwin, Blake D; Aguirre, Paula; Appel, John W; Bond, J Richard; Carvalho, C Sofia; Devlin, Mark J; Dunkley, Joanna; Dünner, Rolando; Essinger-Hileman, Thomas; Fowler, Joseph W; Hajian, Amir; Halpern, Mark; Hasselfield, Matthew; Hincks, Adam D; Hlozek, Renée; Huffenberger, Kevin M; Hughes, John P; Irwin, Kent D; Klein, Jeff; Kosowsky, Arthur; Lupton, Robert H; Marriage, Tobias A; Marsden, Danica; Menanteau, Felipe; Moodley, Kavilan; Niemack, Michael D; Nolta, Michael R; Page, Lyman A; Parker, Lucas; Reese, Erik D; Schmitt, Benjamin L; Sehgal, Neelima; Sievers, Jon; Spergel, David N; Staggs, Suzanne T; Swetz, Daniel S; Switzer, Eric R; Thornton, Robert; Visnjic, Katerina; Wollack, Ed
2011-07-08
We report the first detection of the gravitational lensing of the cosmic microwave background through a measurement of the four-point correlation function in the temperature maps made by the Atacama Cosmology Telescope. We verify our detection by calculating the levels of potential contaminants and performing a number of null tests. The resulting convergence power spectrum at 2° angular scales measures the amplitude of matter density fluctuations on comoving length scales of around 100 Mpc at redshifts around 0.5 to 3. The measured amplitude of the signal agrees with Lambda cold dark matter cosmology predictions. Since the amplitude of the convergence power spectrum scales as the square of the amplitude of the density fluctuations, the 4σ detection of the lensing signal measures the amplitude of density fluctuations to 12%.
Cluster richness-mass calibration with cosmic microwave background lensing
NASA Astrophysics Data System (ADS)
Geach, James E.; Peacock, John A.
2017-11-01
Identifying galaxy clusters through overdensities of galaxies in photometric surveys is the oldest1,2 and arguably the most economical and mass-sensitive detection method3,4, compared with X-ray5-7 and Sunyaev-Zel'dovich effect8 surveys that detect the hot intracluster medium. However, a perennial problem has been the mapping of optical `richness' measurements onto total cluster mass3,9-12. Emitted at a conformal distance of 14 gigaparsecs, the cosmic microwave background acts as a backlight to all intervening mass in the Universe, and therefore has been gravitationally lensed13-15. Experiments such as the Atacama Cosmology Telescope16, South Pole Telescope17-19 and the Planck20 satellite have now detected gravitational lensing of the cosmic microwave background and produced large-area maps of the foreground deflecting structures. Here we present a calibration of cluster optical richness at the 10% level by measuring the average cosmic microwave background lensing measured by Planck towards the positions of large numbers of optically selected clusters, detecting the deflection of photons by structures of total mass of order 1014 M⊙. Although mainly aimed at the study of larger-scale structures, the Planck estimate of the cosmic microwave background lensing field can be used to recover a nearly unbiased lensing signal for stacked clusters on arcminute scales15,21. This approach offers a clean measure of total cluster masses over most of cosmic history, largely independent of baryon physics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Z.Y.; Boice, J.D. Jr.; Wei, L.X.
1990-03-21
Thyroid nodularity following continuous low-dose radiation exposure in China was determined in 1,001 women aged 50-65 years who resided in areas of high background radiation (330 mR/yr) their entire lives, and in 1,005 comparison subjects exposed to normal levels of radiation (114 mR/yr). Cumulative doses to the thyroid were estimated to be of the order of 14 cGy and 5 cGy, respectively. Personal interviews and physical examinations were conducted, and measurements were made of serum thyroid hormone levels, urinary iodine concentrations, and chromosome aberrations in circulating lymphocytes. For all nodular disease, the prevalences in the high background and control areasmore » were 9.5% and 9.3%, respectively. For single nodules, the prevalences were 7.4% in the high background area and 6.6% in the control area (prevalence ratio = 1.13; 95% confidence interval = 0.82-1.55). There were no differences found in serum levels of thyroid hormones. Women in the high background region, however, had significantly lower concentrations of urinary iodine and significantly higher frequencies of stable and unstable chromosome aberrations. Increased intake of allium vegetables such as garlic and onions was associated with a decreased risk of nodular disease, which seems consistent with experimental studies suggesting that allium compounds can inhibit tumor growth and proliferation. The prevalence of mild diffuse goiter was higher in the high background radiation region, perhaps related to a low dietary intake of iodine. These data suggest that continuous exposure to low-level radiation throughout life is unlikely to appreciably increase the risk of thyroid cancer. However, such exposure may cause chromosomal damage.« less
Study of the Residual Background Events in Ground Data from the ASTRO-HSXS Microcalorimeter
NASA Technical Reports Server (NTRS)
Kilbourne, Caroline A.; Boyce, Kevin R.; Chiao, M. P.; Eckart, M. E.; Kelley, R. L.; Leutenegger, M. A.; Porter, F. S.; Watanabe, T.; Ishisaki, Y.; Yamada, S.;
2015-01-01
The measured instrumental background of the XRS calorimeter spectrometer of Suzaku had several sources, including primary cosmic rays and secondary particles interacting with the pixels and with the silicon structure of the array. Prior to the launch of Suzaku, several data sets were taken without x-ray illumination to study the characteristics and timing of background signals produced in the array and anti-coincidence detector. Even though the source of the background in the laboratory was different from that in low-earth orbit (muons and environmental gamma-rays on the ground versus Galactic cosmic-ray (GCR) protons and alpha particles in space), the study of correlations and properties of populations of rare events was useful for establishing the preliminary screening parameters needed for selection of good science data. Sea-level muons are singly charged minimum-ionizing particles, like the GCR protons, and thus were good probes of the effectiveness of screening via the signals from the anti-coincidence detector. Here we present the first analysis of the on-ground background of the SXS calorimeter of Astro-H. On XRS, the background prior to screening was completely dominated by coincident events on many pixels resulting from the temperature pulse arising from each large energy deposition (greater than 200 keV) into the silicon frame around the array. The improved heat-sinking of the SXS array compared with XRS eliminated these thermal disturbances, greatly reducing the measured count rate in the absence of illumination. The removal of these events has made it easier to study the nature of the residual background and to look for additional event populations. We compare the SXS residual background to that measured in equivalent ground data for XRS and discuss these preliminary results.
Isotopic tracking of Hanford 300 area derived uranium in the Columbia River.
Christensen, John N; Dresel, P Evan; Conrad, Mark E; Patton, Gregory W; DePaolo, Donald J
2010-12-01
Our objectives in this study are to quantify the discharge rate of uranium (U) to the Columbia River from the Hanford Site's 300 Area and to follow that U downriver to constrain its fate. Uranium from the Hanford Site has variable isotopic composition due to nuclear industrial processes carried out at the site. This characteristic makes it possible to use high-precision isotopic measurements of U in environmental samples to identify even trace levels of contaminant U, determine its sources, and estimate discharge rates. Our data on river water samples indicate that as much as 3.2 kg/day can enter the Columbia River from the 300 Area, which is only a small fraction of the total load of dissolved natural background U carried by the Columbia River. This very low level of Hanford-derived U can be discerned, despite dilution to <1% of natural background U, 400 km downstream from the Hanford Site. These results indicate that isotopic methods can allow the amounts of U from the 300 Area of the Hanford Site entering the Columbia River to be measured accurately to ascertain whether they are an environmental concern or insignificant relative to natural uranium background in the Columbia River.
Optical Design Considerations for Efficient Light Collection from Liquid Scintillation Counters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernacki, Bruce E.; Douglas, Matthew; Erchinger, Jennifer L.
2015-01-01
Liquid scintillation counters measure charged particle-emitting radioactive isotopes and are used for environmental studies, nuclear chemistry, and life science. Alpha and beta emissions arising from the material under study interact with the scintillation cocktail to produce light. The prototypical liquid scintillation counter employs low-level photon-counting detectors to measure the arrival of the scintillation light produced as a result of the dissolved material under study interacting with the scintillation cocktail. For reliable operation the counting instrument must convey the scintillation light to the detectors efficiently and predictably. Current best practices employ the use of two or more detectors for coincidence processingmore » to discriminate true scintillation events from background events due to instrumental effects such as photomultiplier tube dark rates, tube flashing, or other light emission not generated in the scintillation cocktail vial. In low background liquid scintillation counters additional attention is paid to shielding the scintillation cocktail from naturally occurring radioactive material (NORM) present in the laboratory and within the instruments construction materials. Low background design is generally at odds with optimal light collection. This study presents the evolution of a light collection design for liquid scintillation counting in a low background shield. The basic approach to achieve both good light collection and a low background measurement is described. The baseline signals arising from the scintillation vial are modeled and methods to efficiently collect scintillation light are presented as part of the development of a customized low-background, high sensitivity liquid scintillation counting system.« less
Intergenerational preferences for radio loudness during automobile driving.
Hanser, Frederick Howard Bateman; Adjei Boakye, Eric; Mikulec, Anthony Alan
2017-07-01
The comparative contribution to human noise exposure from the vehicular radio is unknown, as are the radio volume preferences of different generations when driving an automobile. A single vehicle was used to measure radio listening level in decibels of three generations (age 16-17 years, age 32-50 years, and age 51-73 years) in various conditions, ranging from engine off with windows closed to 60 miles per hour (mph) with windows open. No differences in radio loudness based on the sex of the driver were found. Statistically significant differences were identified in preferred signal to noise ratio among multiple vehicular paradigms, with the youngest generation preferring the largest signal to noise ratio in conditions with low background noise. The youngest generation favored the largest signal to noise ratio (radio level above background noise), a preference which waned with increasing background noise. Copyright © 2017 Elsevier B.V. All rights reserved.
Incorporating signal-dependent noise for hyperspectral target detection
NASA Astrophysics Data System (ADS)
Morman, Christopher J.; Meola, Joseph
2015-05-01
The majority of hyperspectral target detection algorithms are developed from statistical data models employing stationary background statistics or white Gaussian noise models. Stationary background models are inaccurate as a result of two separate physical processes. First, varying background classes often exist in the imagery that possess different clutter statistics. Many algorithms can account for this variability through the use of subspaces or clustering techniques. The second physical process, which is often ignored, is a signal-dependent sensor noise term. For photon counting sensors that are often used in hyperspectral imaging systems, sensor noise increases as the measured signal level increases as a result of Poisson random processes. This work investigates the impact of this sensor noise on target detection performance. A linear noise model is developed describing sensor noise variance as a linear function of signal level. The linear noise model is then incorporated for detection of targets using data collected at Wright Patterson Air Force Base.
ERIC Educational Resources Information Center
Larsen, Junilla K.; Kleinjan, Marloes; Engels, Rutger C. M. E.; Fisher, Jennifer O.; Hermans, Roel
2014-01-01
Background: The purpose of this study was to examine the association between adolescents' body mass index (BMI) z-scores and their subsequent level of schooling, extending previous longitudinal research by using objectively measured weight and height data. Methods: A longitudinal study with 3 study waves (1-year intervals) involving 1248 Dutch…
Surface alpha backgrounds from plate-out of radon progeny
NASA Astrophysics Data System (ADS)
Perumpilly, Gopakumar; Guiseppe, Vincente
2012-03-01
Low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly Rn-222) and its subsequent daughters present in an experiment are potential backgrounds, more troublesome is the deposition of radon daughters on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by daughters supported by the long half life (22 y) of Pb-210 on sensitive locations of a detector. We have developed a model of the radon progeny implantation using Geant4 simulations based on the low energy nuclear recoil process. We explore the alpha decays from implanted progeny on a Ge crystal as potential backgrounds for a neutrinoless double-beta decay experiment. Results of the simulations validated with alpha spectrum measurement of plate-out samples will be presented.
Modeling surface backgrounds from radon progeny plate-out
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perumpilly, G.; Guiseppe, V. E.; Snyder, N.
2013-08-08
The next generation low-background detectors operating deep underground aim for unprecedented low levels of radioactive backgrounds. The surface deposition and subsequent implantation of radon progeny in detector materials will be a source of energetic background events. We investigate Monte Carlo and model-based simulations to understand the surface implantation profile of radon progeny. Depending on the material and region of interest of a rare event search, these partial energy depositions can be problematic. Motivated by the use of Ge crystals for the detection of neutrinoless double-beta decay, we wish to understand the detector response of surface backgrounds from radon progeny. Wemore » look at the simulation of surface decays using a validated implantation distribution based on nuclear recoils and a realistic surface texture. Results of the simulations and measured α spectra are presented.« less
Kinsey, Thomas P; Lydon, Keri A; Bowers, John C; Jones, Jessica L
2015-08-01
Vibrio vulnificus (Vv) and Vibrio parahaemolyticus (Vp) are the two leading causes of bacterial illnesses associated with raw shellfish consumption. Levels of these pathogens in oysters can increase during routine antifouling aquaculture practices involving dry storage in ambient air conditions. After storage, common practice is to resubmerge these stored oysters to reduce elevated Vv and Vp levels, but evidence proving the effectiveness of this practice is lacking. This study examined the changes in Vv and in total and pathogenic (thermostable direct hemolysin gene and the tdh-related hemolysin gene, tdh+ and trh+) Vp levels in oysters after 5 or 24 h of dry storage (28 to 32°C), followed by resubmersion (27 to 32°C) for 14 days. For each trial, replicate oyster samples were collected at initial harvest, after dry storage, after 7 days, and after 14 days of resubmersion. Oysters not subjected to dry storage were collected and analyzed to determine natural undisturbed vibrio levels (background control). Vibrio levels were measured using a most-probable-number enrichment followed by real-time PCR. After storage, vibrio levels (excluding tdh+ and trh+ Vp during 5-h storage) increased significantly (P < 0.001) from initial levels. After 7 days of resubmersion, Vv and total Vp levels (excluding total Vp in oysters stored for 5 h) were not significantly different (P < 0.1) from levels in background oysters. Vv and total and pathogenic Vp levels were not significantly different (P > 0.1) from levels in background oysters after 14 days of resubmersion, regardless of dry storage time. These data demonstrate that oyster resubmersion after dry storage at elevated ambient temperatures allows vibrio levels to return to those of background control samples. These results can be used to help minimize the risk of Vv and Vp illnesses and to inform the oyster industry on the effectiveness of routine storing and resubmerging of aquaculture oysters.
Noise analysis of the seismic system employed in the northern and southern California seismic nets
Eaton, J.P.
1984-01-01
The seismic networks have been designed and operated to support recording on Develocorders (less than 40db dynamic range) and analog magnetic tape (about 50 db dynamic range). The principal analysis of the records has been based on Develocorder films; and background earth noise levels have been adjusted to be about 1 to 2 mm p-p on the film readers. Since the traces are separated by only 10 to 12 mm on the reader screen, they become hopelessly tangled when signal amplitudes on several adjacent traces exceed 10 to 20 mm p-p. Thus, the background noise level is hardly more than 20 db below the level of largest readable signals. The situation is somewhat better on tape playbacks, but the high level of background noise set to accomodate processing from film records effectively limits the range of maximum-signal to background-earth-noise on high gain channels to a little more than 30 db. Introduction of the PDP 11/44 seismic data acquisition system has increased the potential dynamic range of recorded network signals to more than 60 db. To make use of this increased dynamic range we must evaluate the characteristics and performance of the seismic system. In particular, we must determine whether the electronic noise in the system is or can be made sufficiently low so that background earth noise levels can be lowered significantly to take advantage of the increased dynamic range of the digital recording system. To come to grips with the complex problem of system noise, we have carried out a number of measurements and experiments to evaluate critical components of the system as well as to determine the noise characteristics of the system as a whole.
Psychophysical and perceptual performance in a simulated-scotoma model of human eye injury
NASA Astrophysics Data System (ADS)
Brandeis, R.; Egoz, I.; Peri, D.; Sapiens, N.; Turetz, J.
2008-02-01
Macular scotomas, affecting visual functioning, characterize many eye and neurological diseases like AMD, diabetes mellitus, multiple sclerosis, and macular hole. In this work, foveal visual field defects were modeled, and their effects were evaluated on spatial contrast sensitivity and a task of stimulus detection and aiming. The modeled occluding scotomas, of different size, were superimposed on the stimuli presented on the computer display, and were stabilized on the retina using a mono Purkinje Eye-Tracker. Spatial contrast sensitivity was evaluated using square-wave grating stimuli, whose contrast thresholds were measured using the method of constant stimuli with "catch trials". The detection task consisted of a triple conjunctive visual search display of: size (in visual angle), contrast and background (simple, low-level features vs. complex, high-level features). Search/aiming accuracy as well as R.T. measures used for performance evaluation. Artificially generated scotomas suppressed spatial contrast sensitivity in a size dependent manner, similar to previous studies. Deprivation effect was dependent on spatial frequency, consistent with retinal inhomogeneity models. Stimulus detection time was slowed in complex background search situation more than in simple background. Detection speed was dependent on scotoma size and size of stimulus. In contrast, visually guided aiming was more sensitive to scotoma effect in simple background search situation than in complex background. Both stimulus aiming R.T. and accuracy (precision targeting) were impaired, as a function of scotoma size and size of stimulus. The data can be explained by models distinguishing between saliency-based, parallel and serial search processes, guiding visual attention, which are supported by underlying retinal as well as neural mechanisms.
Rosselli, Mónica; Ardila, Alfredo
2003-08-01
Clinical neuropsychology has frequently considered visuospatial and non-verbal tests to be culturally and educationally fair or at least fairer than verbal tests. This paper reviews the cross-cultural differences in performance on visuoperceptual and visuoconstructional ability tasks and analyzes the impact of education and culture on non-verbal neuropsychological measurements. This paper compares: (1) non-verbal test performance among groups with different educational levels, and the same cultural background (inter-education intra-culture comparison); (2) the test performance among groups with the same educational level and different cultural backgrounds (intra-education inter-culture comparisons). Several studies have demonstrated a strong association between educational level and performance on common non-verbal neuropsychological tests. When neuropsychological test performance in different cultural groups is compared, significant differences are evident. Performance on non-verbal tests such as copying figures, drawing maps or listening to tones can be significantly influenced by the individual's culture. Arguments against the use of some current neuropsychological non-verbal instruments, procedures, and norms in the assessment of diverse educational and cultural groups are discussed and possible solutions to this problem are presented.
Quantitative Proteomics via High Resolution MS Quantification: Capabilities and Limitations
Higgs, Richard E.; Butler, Jon P.; Han, Bomie; Knierman, Michael D.
2013-01-01
Recent improvements in the mass accuracy and resolution of mass spectrometers have led to renewed interest in label-free quantification using data from the primary mass spectrum (MS1) acquired from data-dependent proteomics experiments. The capacity for higher specificity quantification of peptides from samples enriched for proteins of biological interest offers distinct advantages for hypothesis generating experiments relative to immunoassay detection methods or prespecified peptide ions measured by multiple reaction monitoring (MRM) approaches. Here we describe an evaluation of different methods to post-process peptide level quantification information to support protein level inference. We characterize the methods by examining their ability to recover a known dilution of a standard protein in background matrices of varying complexity. Additionally, the MS1 quantification results are compared to a standard, targeted, MRM approach on the same samples under equivalent instrument conditions. We show the existence of multiple peptides with MS1 quantification sensitivity similar to the best MRM peptides for each of the background matrices studied. Based on these results we provide recommendations on preferred approaches to leveraging quantitative measurements of multiple peptides to improve protein level inference. PMID:23710359
Monte-Carlo background simulations of present and future detectors in x-ray astronomy
NASA Astrophysics Data System (ADS)
Tenzer, C.; Kendziorra, E.; Santangelo, A.
2008-07-01
Reaching a low-level and well understood internal instrumental background is crucial for the scientific performance of an X-ray detector and, therefore, a main objective of the instrument designers. Monte-Carlo simulations of the physics processes and interactions taking place in a space-based X-ray detector as a result of its orbital environment can be applied to explain the measured background of existing missions. They are thus an excellent tool to predict and optimize the background of future observatories. Weak points of a design and the main sources of the background can be identified and methods to reduce them can be implemented and studied within the simulations. Using the Geant4 Monte-Carlo toolkit, we have created a simulation environment for space-based detectors and we present results of such background simulations for XMM-Newton's EPIC pn-CCD camera. The environment is also currently used to estimate and optimize the background of the future instruments Simbol-X and eRosita.
Measurement of tritium in natural water
NASA Astrophysics Data System (ADS)
Li, Meifen
1985-06-01
A detergent-scintillation liquid mixture applied to measure low specific activity of tritium in natural water was studied. The DYS-1 low level liquid scintillation counter designed and manufactured by our institute was employed. In comparing the Triton X-100 scintillation liquid mixture with the dioxane-based-scintillation liquid, a better formula for Triton X-100 scintillation liquid mixture was determined, the mixture possesses the quality of high water content; high efficiency and low back-ground in measuring tritium in water. Chemiluminescence of the Triton X-100 scintillation liquid mixture can be totally de-excited in short time. It can be employed at ambient temperature 11 28°C. For 20ml sample in quartz vials, counting efficiency is 15% with a background 2.17 cpm, Y=31 TU (t=30 min).
Summer ammonia measurements in a densely populated Mediterranean city
NASA Astrophysics Data System (ADS)
Pandolfi, M.; Amato, F.; Reche, C.; Alastuey, A.; Otjes, R. P.; Blom, M. J.; Querol, X.
2012-08-01
Real-time measurements of ambient concentrations of gas-phase ammonia (NH3) were performed in Barcelona (NE Spain) in summer between May and September 2011. Two measurement sites were selected: one in an urban background traffic-influenced area (UB) and the other in the historical city centre (CC). Levels of NH3 were higher at CC (5.6 ± 2.1 μg m-3 or 7.5 ± 2.8 ppbv) compared with UB (2.2 ± 1.0 μg m-3 or 2.9 ± 1.3 ppbv). This difference is attributed to the contribution from non-traffic sources such as waste containers, sewage systems, humans and open markets more dense in the densely populated historical city centre. Under high temperatures in summer these sources had the potential to increase the ambient levels of NH3 well above the urban-background-traffic-influenced UB measurement station. Measurements were used to assess major local emissions, sinks and diurnal evolution of NH3. The measured levels of NH3, especially high in the old city, may contribute to the high mean annual concentrations of secondary sulfate and nitrate measured in Barcelona compared with other cities in Spain affected by high traffic intensity. Ancillary measurements, including PM10, PM2.5, PM1 levels (Particulate Matter with aerodynamic diameter smaller than 10 μm, 2.5 μm, and 1 μm), gases and black carbon concentrations and meteorological data, were performed during the measurement campaign. The analysis of specific periods (3 special cases) during the campaign revealed that road traffic was a significant source of NH3. However, its effect was more evident at UB compared with CC where it was masked given the high levels of NH3 from non-traffic sources measured in the old city. The relationship between SO42- daily concentrations and gas-fraction ammonia (NH3/(NH3 + NH4+)) revealed that the gas-to-particle phase partitioning (volatilization or ammonium salts formation) also played an important role in the evolution of NH3 concentration in summer in Barcelona.
Summer ammonia measurements in a densely populated Mediterranean city
NASA Astrophysics Data System (ADS)
Pandolfi, M.; Amato, F.; Reche, C.; Alastuey, A.; Otjes, R. P.; Blom, M. J.; Querol, X.
2012-04-01
Real-time measurements of ambient concentrations of gas-phase ammonia were performed in Barcelona (NE Spain) in summer between May and September 2011. Two measurement sites were selected: one in an urban background traffic-influenced area (UB) and the other in the historical city centre (CC). Levels of ammonia were higher at CC (5.6 ± 2.1 μg m-3 or 7.5 ± 2.8 ppbv) compared with UB (2.2 ± 1.0 μg m-3 or 2.9 ± 1.3 ppbv). This difference is attributed to the contribution from non-traffic sources such as waste containers, sewage systems, humans and open markets more dense in the densely populated historical city centre. Under high temperatures in summer these sources had the potential to increase the ambient levels of ammonia well above the urban-background-traffic-influenced UB measurement station. Measurements were used to assess major local emissions, sinks and diurnal evolution of NH3. The measured levels of NH3, especially high in the old city, may contribute to the high mean annual concentrations of secondary sulfate and nitrate measured in Barcelona compared with other cities in Spain affected by high traffic intensity. Ancillary measurements, including PM10, PM2.5, PM1 levels (Particulate Matter with aerodynamic diameter smaller than 10 μm, 2.5 μm, and 1 μm), gases and black carbon concentrations and meteorological data, were performed during the measurement campaign. The analysis of specific periods (3 special cases) during the campaign revealed that road traffic was a significant source of NH3. However, its effect was more evident at UB compared with CC where it was masked given the high levels of NH3 from non-traffic sources measured in the old city. The relationship between SO42- daily concentrations and gas-fraction ammonia (NH3/(NH3+NH4+)) revealed that the gas-to-phase partitioning (volatilization or ammonium salts formation) also played an important role in the evolution of NH3 concentration in summer in Barcelona.
ERIC Educational Resources Information Center
McCarthy, Mary L.
2006-01-01
This article challenges Perry's research using performance evaluations to determine whether the educational background of child welfare workers is predictive of performance. Institutional theory, an understanding of street-level bureaucracies, and evaluations of field education performance measures are offered as necessary frameworks for Perry's…
ERIC Educational Resources Information Center
Verstraelen, C. J. F.; Maaskant, M. A.; van Knijff-Raeven, A. G. M.; Curfs, L. M. G.; van Schrojenstein Lantman-de Valk, H. M. J.
2009-01-01
Background: The aims of this study were (1) to determine to what extent body mass index (BMI), waist circumference, fat free mass index (FFMI) and skinfold thickness are feasible measurement options in people with intellectual disabilities (ID) to measure their weight status, and (2) to assess the level of agreement among these methods. Methods:…
Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette.
Altuncu, E; Akman, I; Kulekci, S; Akdas, F; Bilgen, H; Ozek, E
2009-07-01
The purposes of this study were to measure the noise level of a busy neonatal intensive care unit (NICU) and to determine the effect of sound absorbing panel (SAP) on the level of noise inside the isolette. The sound pressure levels (SPL) of background noise, baby crying, alarms and closing of isolette's door/portholes were measured by a 2235-Brüel&Kjaer Sound Level Meter. Readings were repeated after applying SAP (3D pyramidal shaped open cell polyurethane foam) to the three lateral walls and ceiling of the isolette. The median SPL of background noise inside the NICU was 56dBA and it decreased to 47dBA inside the isolette. The median SPL of monitor alarms and baby crying inside the isolette were not different than SPL measured under radiant warmer (p>0.05). With SAP, the median SPL of temperature alarm inside the isolette decreased significantly from 82 to 72dBA, monitor alarm from 64 to 56dBA, porthole closing from 81 to 74dBA, and isolette door closing from 80 to 68dBA (p<0.01). There was a significant reduction in the noise produced by baby crying when SAP was used in the isolette (79dBA vs 69dBA, respectively) (p<0.0001). There was also significant attenuation effect of panel on the environmental noise. The noise level in our NICU is significantly above the universally recommended levels. Being inside the isolette protects infants from noise sources produced outside the isolette. However, very high noises are produced inside the isolette as well. Sound absorbing panel can be a simple solution and it attenuated the noise levels inside the isolette.
First Intrinsic Anisotropy Observations With the Cosmic Background Imager
NASA Technical Reports Server (NTRS)
Padin, S.; Cartwright, J. K.; Mason, B. S.; Pearson, T. J.; Readhead, A. C. S.; Shepherd, M. C.; Sievers, J.; Udomprasert, P. S.; Holzapfel, W. L.; Myers, S. T.;
2001-01-01
We present the first results of observations of the intrinsic anisotropy of the cosmic microwave background radiation with the Cosmic Background Imager from a site at 5080 in altitude in northern Chile. Our observations show a sharp decrease in C_l in the range l = 400 - 1500. Such a decrease in power at high l is one of the fundamental predictions of the standard cosmological model, and these are the first observations which cover a broad enough 1-range to show this decrease in a single experiment. The power, C_l, at l approximately 600 is higher than measured by Boomerang and Maxima, with the differences being significant at the 2.7sigma and 1.9sigma levels, respectively. The C_l we have measured enable us to place limits on the density parameter, Omega(tot) <= 0.4 or Omega(tot) >= 0.7 (90% confidence).
Revised radiometric calibration technique for LANDSAT-4 Thematic Mapper data
NASA Technical Reports Server (NTRS)
Murphy, J.; Butlin, T.; Duff, P.; Fitzgerald, A.
1984-01-01
Depending on detector number, there are random fluctuations in the background level for spectral band 1 of magnitudes ranging from 2 to 3.5 digital numbers (DN). Similar variability is observed in all the other reflective bands, but with smaller magnitude in the range 0.5 to 2.5 DN. Observations of background reference levels show that line dependent variations in raw TM image data and in the associated calibration data can be measured and corrected within an operational environment by applying simple offset corrections on a line-by-line basis. The radiometric calibration procedure defined by the Canadian Center for Remote Sensing was revised accordingly in order to prevent striping in the output product.
Evidence for cosmological particle creation?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pigozzo, C.; Carneiro, S.; Borges, H.A.
2016-05-01
A joint analysis of the linear matter power spectrum, distance measurements from type Ia supernovae and the position of the first peak in the anisotropy spectrum of the cosmic microwave background indicates a cosmological, late-time dark matter creation at 95% confidence level.
641 N Michigan, September 2011, Lindsay Light Radiological Survey
The unshielded field gamma measurements within the spoil matehals generated during the drilling processdid not exceed the respective threshold values previously stated and ranged from background levels of 4,000cpm to a maximum of about 8,000 cpm.
Evaluation of the annoyance due to helicopter rotor noise
NASA Technical Reports Server (NTRS)
Sternfeld, H., Jr.; Doyle, L. B.
1978-01-01
A program was conducted in which 25 test subjects adjusted the levels of various helicopter rotor spectra until the combination of the harmonic noise and a broadband background noise was judged equally annoying as a higher level of the same broadband noise spectrum. The subjective measure of added harmonic noise was equated to the difference in the two levels of broadband noise. The test participants also made subjective evaluations of the rotor noise signatures which they created. The test stimuli consisted of three degrees of rotor impulsiveness, each presented at four blade passage rates. Each of these 12 harmonic sounds was combined with three broadband spectra and was adjusted to match the annoyance of three different sound pressure levels of broadband noise. Analysis of variance indicated that the important variables were level and impulsiveness. Regression analyses indicated that inclusion of crest factor improved correlation between the subjective measures and various objective or physical measures.
Background studies of high energy γ rays from (n,γ) reactions in the CANDLES experiment
NASA Astrophysics Data System (ADS)
Nakajima, K.; Iida, T.; Akutagawa, K.; Batpurev, T.; Chan, W. M.; Dokaku, F.; Fushimi, K.; Kakubata, H.; Kanagawa, K.; Katagiri, S.; Kawasaki, K.; Khai, B. T.; Kino, H.; Kinoshita, E.; Kishimoto, T.; Hazama, R.; Hiraoka, H.; Hiyama, T.; Ishikawa, M.; Li, X.; Maeda, T.; Matsuoka, K.; Moser, M.; Nomachi, M.; Ogawa, I.; Ohata, T.; Sato, H.; Shamoto, K.; Shimada, M.; Shokati, M.; Takahashi, N.; Takemoto, Y.; Takihira, Y.; Tamagawa, Y.; Tozawa, M.; Teranishi, K.; Tetsuno, K.; Trang, V. T. T.; Tsuzuki, M.; Umehara, S.; Wang, W.; Yoshida, S.; Yotsunaga, N.
2018-07-01
High energy γ rays with several MeV produced by (n,γ) reactions can be a trouble for low background measurements in the underground laboratories such as double beta decay experiments. In the CANDLES project, which aimed to observe the neutrino-less double beta decay from 48Ca, γ rays caused by (n,γ) reactions were found to be the most significant background. The profile of the background was studied by measurements with a neutron source and a simulation with a validity check of neutron processes in Geant4. The observed spectrum of γ rays from (n,γ) reactions was well reproduced by the simulated spectra, which were originated from the surrounding rock and a detector tank made of stainless steel. The environmental neutron flux was derived by the observed event rate of γ rays from (n,γ) reactions using the simulation. The thermal and non-thermal neutron flux were found to be (1.3 ± 0.6) ×10-6 cm-2s-1 and (1.1 ± 0.5) ×10-5 cm-2s-1 , respectively. It is necessary to install an additional shield to reduce the background from (n,γ) reaction to the required level.
Fourier-space combination of Planck and Herschel images
NASA Astrophysics Data System (ADS)
Abreu-Vicente, J.; Stutz, A.; Henning, Th.; Keto, E.; Ballesteros-Paredes, J.; Robitaille, T.
2017-08-01
Context. Herschel has revolutionized our ability to measure column densities (NH) and temperatures (T) of molecular clouds thanks to its far infrared multiwavelength coverage. However, the lack of a well defined background intensity level in the Herschel data limits the accuracy of the NH and T maps. Aims: We aim to provide a method that corrects the missing Herschel background intensity levels using the Planck model for foreground Galactic thermal dust emission. For the Herschel/PACS data, both the constant-offset as well as the spatial dependence of the missing background must be addressed. For the Herschel/SPIRE data, the constant-offset correction has already been applied to the archival data so we are primarily concerned with the spatial dependence, which is most important at 250 μm. Methods: We present a Fourier method that combines the publicly available Planck model on large angular scales with the Herschel images on smaller angular scales. Results: We have applied our method to two regions spanning a range of Galactic environments: Perseus and the Galactic plane region around l = 11deg (HiGal-11). We post-processed the combined dust continuum emission images to generate column density and temperature maps. We compared these to previously adopted constant-offset corrections. We find significant differences (≳20%) over significant ( 15%) areas of the maps, at low column densities (NH ≲ 1022 cm-2) and relatively high temperatures (T ≳ 20 K). We have also applied our method to synthetic observations of a simulated molecular cloud to validate our method. Conclusions: Our method successfully corrects the Herschel images, including both the constant-offset intensity level and the scale-dependent background variations measured by Planck. Our method improves the previous constant-offset corrections, which did not account for variations in the background emission levels. The image FITS files used in this paper are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/604/A65
Achilleos, Souzana; Evans, John S.; Yiallouros, Panayiotis K.; Kleanthous, Savvas; Schwartz, Joel; Koutrakis, Petros
2016-01-01
Air quality in Cyprus is influenced by both local and transported pollution including desert dust storms. We examined PM10 concentration data collected in Nicosia (urban representative) from April 1, 1993 through December 11, 2008, and Ayia Marina (rural background representative) from January 1, 1999 through December 31, 2008. Measurements were conducted using a Tapered Element Oscillating Micro-balance (TEOM). PM10 concentrations, meteorological records and satellite data were used to identify dust storm days. We investigated long term trends using a Generalized Additive Model (GAM) after controlling for day of week, month, temperature, wind speed, and relative humidity. In Nicosia, annual PM10 concentrations ranged from 50.4 to 63.8 μg/m3 and exceeded the EU annual standard limit enacted in 2005 of 40 μg/m3 every year. A large, statistically significant impact of urban sources (defined as the difference between urban and background levels) was seen in Nicosia over the period 2000–2008, and was highest during traffic hours, weekdays, cold months, and low wind conditions. Our estimate of the mean (standard error) contribution of urban sources to the daily ambient PM10 was 24.0 (0.4) μg/m3. The study of yearly trends showed that PM10 levels in Nicosia decreased from 59.4 μg/m3 in 1993 to 49.0 μg/m3 in 2008, probably in part as a result of traffic emission control policies in Cyprus. In Ayia Marina, annual concentrations ranged from 27.3 to 35.6 μg/m3, and no obvious time trends were observed. The levels measured at the Cyprus background site are comparable to background concentrations reported in other Eastern Mediterranean countries. Average daily PM10 concentrations during desert dust storms were around 100 μg/m3 since 2000 and much higher in earlier years. Despite the large impact of dust storms and their increasing frequency over time, dust storms were responsible for a small fraction of the exceedances of the daily PM10 limit. PMID:25562931
Cormier, Susan M; Zheng, Lei; Hayslip, Gretchen; Flaherty, Colleen M
2018-08-15
The concentration of salts in streams is increasing world-wide making freshwater a declining resource. Developing thresholds for freshwater with low specific conductivity (SC), a measure of dissolved ions in water, may protect high quality resources that are refugia for aquatic life and that dilute downstream waters. In this case example, methods are illustrated for estimating protective levels for streams with low SC. The Cascades in the Pacific Northwest of the United States of America was selected for the case study because a geophysical model indicated that the SC of freshwater streams was likely to be very low. Also, there was an insufficient range in the SC data to accurately derive a criterion using the 2011, US Environmental Protection Agency field-based extirpation concentration distribution method. Instead, background and a regression model was used to estimate chronic and acute SC levels that could extirpate 5% of benthic invertebrate genera. Background SC was estimated at the 25th centile (33μS/cm) of the measured data and used as the independent variable in a least squares empirical background-to-criteria (B-C) model. Because no comparison could be made with effect levels estimated from a paired SC and biological data set from the Cascades, the lower 50% prediction limit (PL) was identified as an example chronic water quality criterion (97μS/cm). The maximum exposure threshold was estimated at the 90th centile SC of streams meeting the chronic SC level. The example acute SC level was 190μS/cm. Because paired aquatic life and SC data are often sparse, the B-C method is useful for developing SC criteria for other systems with limited data. Published by Elsevier B.V.
Lessons learned in preparing method 29 filters for compliance testing audits.
Martz, R F; McCartney, J E; Bursey, J T; Riley, C E
2000-01-01
Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.
NASA Technical Reports Server (NTRS)
Dyer, C. S.; Trombka, J. I.; Metzger, A. E.; Seltzer, S. M.; Bielefeld, M. J.; Evans, L. G.
1975-01-01
Since the report of a preliminary analysis of cosmic gamma-ray measurements made during the Apollo 15 mission, an improved calculation of the spallation activation contribution has been made including the effects of short-lived spallation fragments, which can extend the correction to 15 MeV. In addition, a difference between Apollo 15 and 16 data enables an electron bremsstrahlung contribution to be calculated. A high level of activation observed in a crystal returned on Apollo 17 indicates a background contribution from secondary neutrons. These calculations and observations enable an improved extraction of spurious components and suggest important improvements for future detectors.
Cold dark matter and degree-scale cosmic microwave background anisotropy statistics after COBE
NASA Technical Reports Server (NTRS)
Gorski, Krzysztof M.; Stompor, Radoslaw; Juszkiewicz, Roman
1993-01-01
We conduct a Monte Carlo simulation of the cosmic microwave background (CMB) anisotropy in the UCSB South Pole 1991 degree-scale experiment. We examine cold dark matter cosmology with large-scale structure seeded by the Harrison-Zel'dovich hierarchy of Gaussian-distributed primordial inhomogeneities normalized to the COBE-DMR measurement of large-angle CMB anisotropy. We find it statistically implausible (in the sense of low cumulative probability F lower than 5 percent, of not measuring a cosmological delta-T/T signal) that the degree-scale cosmological CMB anisotropy predicted in such models could have escaped a detection at the level of sensitivity achieved in the South Pole 1991 experiment.
First tritium operation of ITER-prototype VUV spectroscopy on JET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coffey, I.H.; Barnsley, R.
Results from tritium operation of the VUV survey spectrometer on the JET tokamak are presented. The instrument, located outside the biological shield and offset from a direct plasma 1-o-s for maximum radiation protection, was operational during the trace tritium campaign (TTE) at JET. No discernible increase in detector background noise levels were detected for total neutron rates of up to 1x10{sup 17}/s, demonstrating the shielding effectiveness of the configuration. Some tritium retention in the detector microchannel plate was measurable, but has not hampered subsequent operations. As a reference the unshielded detector of a close-coupled XUV instrument was operated during TTEmore » (the spectrometer itself was valved off from the JET vessel). This was exposed to neutron fluxes of {approx}10{sup 9}/cm{sup 2} s, in excess of those predicted for the corresponding instrument on ITER (10{sup 7}-10{sup 8}/cm{sup 2} s). A corresponding increase in the background level equivalent to {approx}5% of the detector dynamic range was measured. This demonstration of the shielding effectiveness of the SPRED configuration during DT operations, coupled with the tolerable noise levels measured in the SOXMOS detector, give confidence in the planned implementation of such instruments in ITER.« less
New particle formation at ground level and in the vertical column over the Barcelona area
NASA Astrophysics Data System (ADS)
Minguillón, M. C.; Brines, M.; Pérez, N.; Reche, C.; Pandolfi, M.; Fonseca, A. S.; Amato, F.; Alastuey, A.; Lyasota, A.; Codina, B.; Lee, H.-K.; Eun, H.-R.; Ahn, K.-H.; Querol, X.
2015-10-01
The vertical profiles (up to 975 m a.s.l.) of ultrafine and micronic particles across the planetary boundary layer and the free troposphere over a Mediterranean urban environment were investigated. Measurements were carried out using a tethered balloon equipped with a miniaturized condensation particle counter, a miniaturized optical particle counter, a micro-aethalometer, a rotating impactor, and meteorological instrumentation. Simultaneous ground measurements were carried out at an urban and a regional background site. New particle formation episodes initiating in the urban area were observed under high insolation conditions. The precursors were emitted by the city and urban photochemically-activated nucleation occurred both at high atmospheric levels (tens to hundreds of meters) and at ground level. The new particle formation at ground level was limited by the high particulate matter concentrations recorded during the morning traffic rush hours that increase the condensation sink and prevent new particle formation, and therefore restricted to midday and early afternoon. The aloft new particle formation occurred earlier as the thermally ascending polluted air mass was diluted. The regional background was only affected from midday and early afternoon when sea and mountain breezes transported the urban air mass after particle growth. These events are different from most new particle formation events described in literature, characterized by a regionally originated nucleation, starting early in the morning in the regional background and persisting with a subsequent growth during a long period. An idealized and simplified model of the spatial and time occurrence of these two types of new particle formation episodes into, around and over the city was elaborated.
Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure
NASA Technical Reports Server (NTRS)
Benyo, Theresa L.; Steinetz, Bruce M.; Hendricks, Robert C.; Martin, Richard E.; Forsley, Lawrence P.; Daniels, Christopher C.; Chait, Arnon; Pines, Vladimir; Pines, Marianna; Penney, Nicholas;
2017-01-01
Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 µA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4s confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.
Background/Aims: Perchlorate is a widespread environmental pollutant. Previous population studies based on the National Health and Nutrition Examination Survey (NHANES) 2001-2002, showed that urinary perchlorate concentrations were associated with increased levels of thyroid stim...
The softest sound levels of the human voice in normal subjects.
Šrámková, Hana; Granqvist, Svante; Herbst, Christian T; Švec, Jan G
2015-01-01
Accurate measurement of the softest sound levels of phonation presents technical and methodological challenges. This study aimed at (1) reliably obtaining normative data on sustained softest sound levels for the vowel [a:] at comfortable pitch; (2) comparing the results for different frequency and time weighting methods; and (3) refining the Union of European Phoniatricians' recommendation on allowed background noise levels for scientific and equipment manufacturers' purposes. Eighty healthy untrained participants (40 females, 40 males) were investigated in quiet rooms using a head-mounted microphone and a sound level meter at 30 cm distance. The one-second-equivalent sound levels were more stable and more representative for evaluating the softest sustained phonations than the fast-time-weighted levels. At 30 cm, these levels were in the range of 48-61 dB(C)/41-53 dB(A) for females and 49 - 64 dB(C)/35-53 dB(A) for males (5% to 95% quantile range). These ranges may serve as reference data in evaluating vocal normality. In order to reach a signal-to-noise ratio of at least 10 dB for more than 95% of the normal population, the background noise should be below 25 dB(A) and 38 dB(C), respectively, for the softest phonation measurements at 30 cm distance. For the A-weighting, this is 15 dB lower than the previously recommended value.
Zhou, Qingsheng
2016-01-01
To examine whether differences in access to specialist disability services by people from culturally and linguistically diverse (CALD) backgrounds when compared with those born in Australia represent a service gap or the healthy migrant effect. To use the latest disability statistics to measure the different rates of people with disability, and the rates of people with profound and severe disability, of people born in Australia and those born abroad; to compare the difference between those who mainly speak English with those who primarily speak a language other than English at home (LOTE); and examine the age-specific and standardised disability rates of these subgroups. The rate of access of specialist disability services by people with disability who were from CALD backgrounds is highly disproportionate to their presence in the community. As a whole, people from CALD backgrounds have a similar level of disability as Australia-born people. They have a greater rate of profound and severe disability and a higher level of need for assistance in undertaking core activities. For younger age cohorts targeted by specialist disability services, there is little difference in the level of need for assistance between people from CALD backgrounds and the rest of community. Those people who mainly speak LOTE at home have a relatively higher level of need for assistance than those who speak mainly English at home. The paper reveals a substantial gap in specialist disability services between people from CALD and the broader community. This cannot be explained by the difference in the level of need for assistance between Australia-born and overseas-born populations, therefore raises some policy questions as to the barriers to the use of such services and how to effectively narrow the service access gap and improve utilisation rates. The paper reveals a substantial accessibility gap in specialist disability services between people from culturally and linguistically diverse (CALD) backgrounds and the broader community in Australia. Rehabilitation is a large component of disability services. Therefore, understanding the gap, promoting the awareness of the services, developing appropriate and effective services to respond the need of people with disability from CALD backgrounds, are critically important to rehabilitation services and related research.
Performance of the EDELWEISS-III experiment for direct dark matter searches
NASA Astrophysics Data System (ADS)
Armengaud, E.; Arnaud, Q.; Augier, C.; Benoît, A.; Bergé, L.; Bergmann, T.; Billard, J.; de Boissière, T.; Bres, G.; Broniatowski, A.; Brudanin, V.; Camus, P.; Cazes, A.; Chapellier, M.; Charlieux, F.; De Jésus, M.; Dumoulin, L.; Eitel, K.; Filosofov, D.; Foerster, N.; Fourches, N.; Garde, G.; Gascon, J.; Giuliani, A.; Grollier, M.; Gros, M.; Hehn, L.; Hervé, S.; Heuermann, G.; Humbert, V.; Jin, Y.; Juillard, A.; Kéfélian, C.; Kleifges, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Le-Sueur, H.; Lin, J.; Maisonobe, R.; Mancuso, M.; Marnieros, S.; Menshikov, A.; Navick, X.-F.; Nones, C.; Olivieri, E.; Pari, P.; Paul, B.; Poda, D.; Queguiner, E.; Robinson, M.; Rodenas, H.; Rozov, S.; Sanglard, V.; Schmidt, B.; Scorza, S.; Siebenborn, B.; Tcherniakhovski, D.; Vagneron, L.; Weber, M.; Yakushev, E.; Zhang, X.; Zolotarova, A.
2017-08-01
We present the results of measurements demonstrating the efficiency of the EDELWEISS-III array of cryogenic germanium detectors for direct dark matter searches. The experimental setup and the FID (Fully Inter-Digitized) detector array is described, as well as the efficiency of the double measurement of heat and ionization signals in background rejection. For the whole set of 24 FID detectors used for coincidence studies, the baseline resolutions for the fiducial ionization energy are mainly below 0.7 keVee (FHWM) whereas the baseline resolutions for heat energies are mainly below 1.5 keVee (FWHM). The response to nuclear recoils as well as the very good discrimination capability of the FID design has been measured with an AmBe source. The surface β- and α-decay rejection power of Rsurf < 4 × 10-5 per α at 90% C.L. has been determined with a 210Pb source, the rejection of bulk γ-ray events has been demonstrated using γ-calibrations with 133Ba sources leading to a value of Rγ -mis-fid < 2.5 × 10-6 at 90% C.L.. The current levels of natural radioactivity measured in the detector array are shown as the rate of single γ background. The fiducial volume fraction of the FID detectors has been measured to a weighted average value of (74.6 ± 0.4)% using the cosmogenic activation of the 65Zn and 68,71Ge isotopes. The stability and uniformity of the detector response is also discussed. The achieved resolutions, thresholds and background levels of the upgraded EDELWEISS-III detectors in their setup are thus well suited to the direct search of WIMP dark matter over a large mass range.
Effects of ocular aberrations on contrast detection in noise.
Liang, Bo; Liu, Rong; Dai, Yun; Zhou, Jiawei; Zhou, Yifeng; Zhang, Yudong
2012-08-06
We use adaptive optics (AO) techniques to manipulate the ocular aberrations and elucidate the effects of these ocular aberrations on contrast detection in a noisy background. The detectability of sine wave gratings at frequencies of 4, 8, and 16 circles per degree (cpd) was measured in a standard two-interval force-choice staircase procedure against backgrounds of various levels of white noise. The observer's ocular aberrations were either corrected with AO or left uncorrected. In low levels of external noise, contrast detection thresholds are always lowered by AO correction, whereas in high levels of external noise, they are generally elevated by AO correction. Higher levels of external noise are required to make this threshold elevation observable when signal spatial frequencies increase from 4 to 16 cpd. The linear-amplifier-model fit shows that mostly sampling efficiency and equivalent noise both decrease with AO correction. Our findings indicate that ocular aberrations could be beneficial for contrast detection in high-level noises. The implications of these findings are discussed.
Marie-Desvergne, Caroline; Dubosson, Muriel; Mossuz, Véronique Chamel
2018-05-14
In the field of nanoparticle exposure biomonitoring, oxidative stress biomarkers measured in exhaled breath condensate appear promising to detect early respiratory effects in workers handling nanomaterials. However, condensation is known for its poor efficiency in collecting non-volatiles in exhaled breath, leading to the low sensitivity of such measurements. Moreover, to be easily used in field studies on large groups of workers, the collection device must be disposable and convenient. In this study, we have tested a totally disposable commercial device that allows for the easy dry collection of exhaled air after filtration on a patented filter. The suitability and efficiency of the SensAbues (SB) device for collecting 8-isoprostane were evaluated and compared to the RTube (RT). Seven healthy volunteers performed two 15 min collections of exhaled breath, one with the SB and one with the RT. Blank devices were used to determine the background levels induced by each device. 8-isoprostane was measured in all samples using an EIA technique. The levels of 8-isoprostane in the exhaled breath of volunteers after collection with the SB were significantly higher than those after collection with the RT. Moreover, the levels obtained in volunteers with the SB were significantly higher than background levels obtained in blank devices, which was not the case for the RT. This is the first study to report the ability of the SB device to collect and measure 8-isoprostane in exhaled breath. The proposed method offers better sensitivity than a classical collection with the RT device and should be further explored before future application in biomonitoring studies.
Perfluorocarbon background concentrations in Europe
NASA Astrophysics Data System (ADS)
Straume, Anne Grete; Dietz, Russel N.; Koffı̀, Ernest N.'dri; Nodop, Katrin
Five studies of the background level of several perfluorocarbon compounds in Europe are here presented together with measurements from the European Tracer Experiment (ETEX). The tracers used during the two ETEX tracer releases were the perfluorocarbons (PFCs); perfluoromethylcyclohexane (C 7F 14, PMCH) and perfluoromethylcyclopentane (C 6F 12, PMCP). Their background concentrations were detected by using both passive and active sampling techniques, to define the spatial and temporal variation of the PFCs over Europe. Also the background variations of four isomers of the PFC compound perfluorodimethylcyclohexane (C 8F 16, PDCH) were studied. The results were compared to other PFC tracer studies in the U.S.A. and Europe. The mean and median values of the measured PFCs were found to vary slightly and randomly in space and time. They were found to be higher and to have a larger standard deviation than the measurements from the American studies. The background concentrations were still found to be low and stable enough for PFCs to be highly suitable for use in tracer studies. The following concentrations were found: PMCP; 4.6±0.3 fl ℓ -1, PMCH: 4.6±0.8 fl ℓ -1, ocPDCH: 0.96±0.33 fl ℓ -1, mtPDCH: 9.3±0.8 fl ℓ -1, mcPDCH: 8.8±0.8 fl ℓ -1, ptPDCH: 6.1±0.8 fl ℓ -1. A study of the correlation between the measured PFC compounds showed a significant correlation between most of the compounds, which indicate that there are no major PFC sources in Europe.
Removing Background Noise with Phased Array Signal Processing
NASA Technical Reports Server (NTRS)
Podboy, Gary; Stephens, David
2015-01-01
Preliminary results are presented from a test conducted to determine how well microphone phased array processing software could pull an acoustic signal out of background noise. The array consisted of 24 microphones in an aerodynamic fairing designed to be mounted in-flow. The processing was conducted using Functional Beam forming software developed by Optinav combined with cross spectral matrix subtraction. The test was conducted in the free-jet of the Nozzle Acoustic Test Rig at NASA GRC. The background noise was produced by the interaction of the free-jet flow with the solid surfaces in the flow. The acoustic signals were produced by acoustic drivers. The results show that the phased array processing was able to pull the acoustic signal out of the background noise provided the signal was no more than 20 dB below the background noise level measured using a conventional single microphone equipped with an aerodynamic forebody.
Top-down and bottom-up competition in visual stimuli processing.
Ligeza, Tomasz S; Tymorek, Agnieszka D; Wyczesany, Mirosław
2017-01-01
Limited attention capacity results that not all the stimuli present in the visual field are equally processed. While processing of salient stimuli is automatically boosted by bottom‑up attention, processing of task‑relevant stimuli can be boosted volitionally by top‑down attention. Usually, both top‑down and bottom‑up influences are present simultaneously, which creates a competition between these two types of attention. We examined this competition using both behavioral and electrophysiological measures. Participants responded to letters superimposed on background pictures. We assumed that responding to different conditions of the letter task engages top‑down attention to different extent, whereas processing of background pictures of varying salience engages bottom‑up attention to different extent. To check how manipulation of top‑down attention influences bottom‑up processing, we measured evoked response potentials (ERPs) in response to pictures (engaging mostly bottom‑up attention) during three conditions of a letter task (different levels of top‑down engagement). Conversely, to check how manipulation of bottom‑up attention influences top‑down processing, we measured ERP responses for letters (engaging mostly top‑down attention) while manipulating the salience of background pictures (different levels of bottom‑up engagement). The correctness and reaction times in response to letters were also analyzed. As expected, most of the ERPs and behavioral measures revealed a trade‑off between both types of processing: a decrease of bottom‑up processing was associated with an increase of top‑down processing and, similarly, a decrease of top‑down processing was associated with an increase in bottom‑up processing. Results proved competition between the two types of attentions.
NASA Technical Reports Server (NTRS)
Helgason, K.; Cappelluti, N.; Hasinger, G.; Kashlinsky, A.; Ricotti, M.
2014-01-01
A spatial clustering signal has been established in Spitzer/IRAC measurements of the unresolved cosmic near-infrared background (CIB) out to large angular scales, approx. 1deg. This CIB signal, while significantly exceeding the contribution from the remaining known galaxies, was further found to be coherent at a highly statistically significant level with the unresolved soft cosmic X-ray background (CXB). This measurement probes the unresolved CXB to very faint source levels using deep near-IR source subtraction.We study contributions from extragalactic populations at low to intermediate redshifts to the measured positive cross-power signal of the CIB fluctuations with the CXB. We model the X-ray emission from active galactic nuclei (AGNs), normal galaxies, and hot gas residing in virialized structures, calculating their CXB contribution including their spatial coherence with all infrared emitting counterparts. We use a halo model framework to calculate the auto and cross-power spectra of the unresolved fluctuations based on the latest constraints of the halo occupation distribution and the biasing of AGNs, galaxies, and diffuse emission. At small angular scales (1), the 4.5microns versus 0.5-2 keV coherence can be explained by shot noise from galaxies and AGNs. However, at large angular scales (approx.10), we find that the net contribution from the modeled populations is only able to account for approx. 3% of the measured CIB×CXB cross-power. The discrepancy suggests that the CIB×CXB signal originates from the same unknown source population producing the CIB clustering signal out to approx. 1deg.
In Situ Carbon Dioxide and Methane Measurements from a Tower Network in Los Angeles
NASA Astrophysics Data System (ADS)
Verhulst, K. R.; Karion, A.; Kim, J.; Sloop, C.; Salameh, P.; Yadav, V.; Mueller, K.; Pongetti, T.; Newman, S.; Wong, C.; Hopkins, F. M.; Rao, P.; Miller, J. B.; Keeling, R. F.; Weiss, R. F.; Miller, C. E.; Duren, R. M.; Andrews, A. E.
2016-12-01
Urbanization has concentrated a significant fraction of the world's anthropogenic greenhouse gas (GHG) emissions into a relatively small fraction of the earth's land surface. Concern about rising GHG levels has motivated many nations to begin regulating and/or mitigating emissions, motivating the need for robust, consistent, traceable GHG observation methods in complex urban domains. The Los Angeles Megacity Carbon Project involves continuous and flask sampling of GHGs, trace gases, and isotopes at surface sites situated throughout the greater Los Angeles (LA) area. There are three signals of interest for utilizing urban GHG measurements in local or regional inverse modeling studies: (1) changes in the measured mole fraction at one location within a 24-hour period, (2) gradients in the measured mole fraction between locations within the surface measurement network, (3) local enhancements, or the difference between a measurement at one location and an inferred local "background" mole fraction. We report CO2 and CH4 measurements collected from eleven wavelength-scanned cavity ring-down analyzers (Picarro, Inc.). All sites use an internally consistent sampling protocol and calibration strategy. We show that the LA observation sites exhibit significant GHG enhancements relative to background, with evidence of systematic diurnal, weekly, and monthly variability. In Los Angeles, the "ideal" background sampling location could vary substantially depending on the time of year and local meteorology. Use of a single site for background determination may not be sufficient for reliable determination of GHG enhancements. We estimate the total uncertainty in the enhancement and examine how the choice of background influences the GHG enhancement signal. Uncertainty in GHG enhancements will ultimately translate into uncertainty in the fluxes derived from inverse modeling studies. In future work, the LA surface observations will be incorporated into an inverse-modeling framework to provide "top down," spatially-resolved GHG flux estimates, constrained by observations, for comparison with inventory-based ("bottom-up") estimates.
The nature of the near-infrared interline sky background using fibre Bragg grating OH suppression
NASA Astrophysics Data System (ADS)
Trinh, Christopher Q.; Ellis, Simon C.; Bland-Hawthorn, Joss; Horton, Anthony J.; Lawrence, Jon S.; Leon-Saval, Sergio G.
2013-07-01
We analyse the near-infrared interline sky background, OH and O2 emission in 19 h of H-band observations with the GNOSIS OH-suppression unit and the IRIS2 spectrograph at the 3.9-m Anglo-Australian Telescope. We find that the long-term behaviour of OH emission is best described by a gradual decrease during the first half of the night followed by a gradual increase during the second half of the night following the behaviour of the solar elevation angle. We measure the interline background at 1.520 μm where the instrumental thermal background is very low and study its variation with zenith distance, time after sunset, ecliptic latitude, lunar zenith distance and lunar distance to determine the presence of non-thermal atmospheric emission, zodiacal scattered light and scattered moonlight. Zodiacal scattered light is too faint to be detected in the summed observations. Scattered moonlight due to Mie scattering by atmospheric aerosols is seen at small lunar distances (ρ ≲ 11°), but is otherwise too faint to detect. Except at very small lunar distances the interline background at a resolving power of R ≈ 2400 when using OH-suppression fibres is dominated by a non-thermal atmospheric source with a temporal behaviour that resembles atmospheric OH emission, suggesting that the interline background contains instrumentally scattered OH. However, the interline background dims more rapidly than OH early in the night, suggesting contributions from rapid dimming molecules. The absolute interline background is 560 ± 120 photons s-1 m-2 μm- 1 arcsec-2 under dark conditions. This value is similar to previous measurements without OH suppression, suggesting that non-suppressed atmospheric emission is responsible for the interline background level. Future OH-suppression fibre designs may address this by the suppression of more sky lines using more accurate sky-line measurements taken from high-resolution spectra.
Upper limit on the inner radiation belt MeV electron intensity.
Li, X; Selesnick, R S; Baker, D N; Jaynes, A N; Kanekal, S G; Schiller, Q; Blum, L; Fennell, J; Blake, J B
2015-02-01
No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt. Quantified upper limit of MeV electrons in the inner beltActual MeV electron intensity likely much lower than the upper limitMore detailed understanding of relativistic electrons in the magnetosphere.
Upper limit on the inner radiation belt MeV electron intensity
Li, X; Selesnick, RS; Baker, DN; Jaynes, AN; Kanekal, SG; Schiller, Q; Blum, L; Fennell, J; Blake, JB
2015-01-01
No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt. Key Points Quantified upper limit of MeV electrons in the inner belt Actual MeV electron intensity likely much lower than the upper limit More detailed understanding of relativistic electrons in the magnetosphere PMID:26167446
Background ozone in North China: trends, photochemical and transport impacts
NASA Astrophysics Data System (ADS)
Xu, X.; Lin, W.; Ge, B.
2011-12-01
Tropospheric ozone is one of the key greenhouse gases and plays an important role in atmospheric chemistry. Being a strong oxidant, ozone in the surface layer has significant impacts on human and vegetation health. Long-term measurements of surface ozone are highly needed for climate change assessment and environmental policy-making. Such measurements are scarce, particularly from the background regions. Since 2004, surface ozone and some related reactive gases have been observed at Shangdianzi (SDZ), a Global Atmosphere Watch (GAW) station in North China. Located at the north edge of the Northern China Plain (NCP), the SDZ station is an ideal site for capturing polluted air masses from the NCP sector (southwest) and clean air masses from the background sector (northeast). This facilitates the investigation of impacts of regional transport on surface ozone. In this study, we present long-term measurements of surface ozone made at SDZ, discuss the trends of surface ozone levels in different seasons. Results about the observation-based ozone production efficiency (OPE) for the site will be presented, along with impacts from horizontal and vertical air transport.
Background ozone in North China: trends, photochemical and transport impacts
NASA Astrophysics Data System (ADS)
Xu, X.; Lin, W.; Ge, B.
2012-04-01
Tropospheric ozone is one of the key greenhouse gases and plays an important role in atmospheric chemistry. Being a strong oxidant, ozone in the surface layer has significant impacts on human and vegetation health. Long-term measurements of surface ozone are highly needed for climate change assessment and environmental policy-making. Such measurements are scarce, particularly from the background regions. Since 2004, surface ozone and some related reactive gases have been observed at Shangdianzi (SDZ), a Global Atmosphere Watch (GAW) station in North China. Located at the north edge of the Northern China Plain (NCP), the SDZ station is an ideal site for capturing polluted air masses from the NCP sector (southwest) and clean air masses from the background sector (northeast). This facilitates the investigation of impacts of regional transport on surface ozone. In this study, we present long-term measurements of surface ozone made at SDZ, discuss the trends of surface ozone levels in different seasons. Results about the observation-based ozone production efficiency (OPE) for the site will be presented, along with impacts from horizontal and vertical air transport.
Time-resolved laser spectroscopy of multiply ionized atoms: natural radiative lifetimes in Ce IV.
Zhang, Z G; Svanberg, S; Quinet, P; Palmeri, P; Biémont, E
2001-12-31
Radiative lifetimes have been measured for two excited levels of Ce IV using the time-resolved laser-induced fluorescence technique. Ce3+ ions were produced in a laser-induced plasma. In the measurements, a suitable magnetic field was applied to reduce the recombination between electrons and the ions and thus the background light from the recombination, and special care was exercised to avoid flight-out-of-view effects on the lifetime measurements for the high-velocity ions. The experimental lifetime results, tau = 30(2) ns for the level 49 737 cm(-1) and tau = 30(3) ns for the level 52 226 cm(-1), were compared with relativistic Hartree-Fock calculations (tau = 30.5 and 30.0 ns) indicating a particularly excellent agreement.
Autophagy Signaling in Prostate Cancer: Identification of a Novel Phosphatase
2013-01-01
be attributed to, we measured the activity of wildtype or mutant PTPsigma using a phospho-tyrosine (pTyr) peptide and malachite green free... malachite green (Upstate) and absorbance measured at 650 nm. Background levels from enzyme-only and substrate-only (T yr-P or PtdIns3P) reactions were...peptide at the indicated concentrations for 15 minutes at 37°C and released phosphates measured by malachite green quenching and 650 nm absorbance. (B
Multilevel Interventions: Measurement and Measures
Charns, Martin P.; Alligood, Elaine C.; Benzer, Justin K.; Burgess, James F.; Mcintosh, Nathalie M.; Burness, Allison; Partin, Melissa R.; Clauser, Steven B.
2012-01-01
Background Multilevel intervention research holds the promise of more accurately representing real-life situations and, thus, with proper research design and measurement approaches, facilitating effective and efficient resolution of health-care system challenges. However, taking a multilevel approach to cancer care interventions creates both measurement challenges and opportunities. Methods One-thousand seventy two cancer care articles from 2005 to 2010 were reviewed to examine the state of measurement in the multilevel intervention cancer care literature. Ultimately, 234 multilevel articles, 40 involving cancer care interventions, were identified. Additionally, literature from health services, social psychology, and organizational behavior was reviewed to identify measures that might be useful in multilevel intervention research. Results The vast majority of measures used in multilevel cancer intervention studies were individual level measures. Group-, organization-, and community-level measures were rarely used. Discussion of the independence, validity, and reliability of measures was scant. Discussion Measurement issues may be especially complex when conducting multilevel intervention research. Measurement considerations that are associated with multilevel intervention research include those related to independence, reliability, validity, sample size, and power. Furthermore, multilevel intervention research requires identification of key constructs and measures by level and consideration of interactions within and across levels. Thus, multilevel intervention research benefits from thoughtful theory-driven planning and design, an interdisciplinary approach, and mixed methods measurement and analysis. PMID:22623598
[In-situ measurement of background atmospheric HCFC-142b using GC-MS and GC-ECD method].
Guo, Li-feng; Yao, Bo; Zhou, Ling-xi; Li, Pei-chang; Xu, Lin
2013-05-01
Custom-made GC-MS and GC-ECD in-situ measurement systems were established at the Shangdianzi GAW Regional station. From May 2010 to May 2011, the precisions for GC-MS and GC-ECD systems were 0.23% and 0.88%, respectively, and the HCFC-142b mole fraction during the observation period ranged from 21 x 10(-12) to 355 x 10(-12). The result of the independent-sample T test was P > 0.05, and there was no significant difference in HCFC-142b mole fraction measured by the two systems. The small difference of HCFC-142b mole fraction measured by GC-MS and GC-ECD might be associated with the different sampling time and precision of the two systems. A statistical filter of "robust local regression" was applied to separate HCFC-142b background and pollution data. The mean difference, median difference, 25 and 75 percent difference of background data measured by GC-MS and GC-ECD were all within the precisions. The pollution events captured by the two systems showed similar characters. Results from both systems showed a higher HCFC-142b level in summer and autumn than in winter. The pollution mole fraction of the two systems showed similar seasonal changes.
Effect Measure Modification of Blood Lead-Air Lead Slope Factors
Background: There is abundant literature finding that blood lead (PbB) levels are directly influenced by susceptibility factors including race and ethnicity, age, and housing. However, no study has explored how susceptibility factors influence the PbB-air lead (PbA) relationship...
Toward Understanding Business Student Professional Development Engagement
ERIC Educational Resources Information Center
Blau, Gary; Blessley, Misty; Kunkle, Matthew; Schirmer, Michael; Regan, Laureen
2017-01-01
Professional development engagement (PDE) is defined as the level of perceived undergraduate engagement in professional development activities. An 11-item measure of PDE exhibited a good reliability. Using a complete data sample of 467 graduating business undergraduates, four variable sets (student background or precollege variables,…
Journal Article: Quality Assurance Considerations for An Ambient Dioxin Monitoring Network
The U.S. Environmental Protection Agency initiated the National Dioxin Air Monitoring Network (NDAMN) in 1998. NDAMN has three primary purposes:
1. To provide measurements of background atmospheric levels of dioxin-like compounds in different geographic regions of the Unite...
Enthusiasm and the Effective Modern Academic
ERIC Educational Resources Information Center
Freudenberg, Brett; Samarkovski, Lisa
2014-01-01
Academics today face an array of challenges to their enthusiasm, including teaching students from diverse backgrounds with wavering levels of engagement with their studies. Furthermore, reform to the tertiary education sector has seen the corporatisation of universities with management increasingly measuring academic outcomes in respect of both…
Hoyos, Camilla; Almqvist, Catarina; Garden, Frances; Xuan, Wei; Oddy, Wendy H; Marks, Guy B; Webb, Karen L
2008-01-01
The optimal method for conducting omega (n-)3 polyunsaturated fatty acid (PUFA) supplementation trials in children is unknown. To assess the impact of n-3 and n-6 PUFA intake from the background diet on plasma levels of n-3 and n-6 PUFA in children aged 0-3 years, with and without n-3 supplementation. Subjects were randomised antenatally to receive either n-3 PUFA supplements and low n-6 PUFA cooking oils and spreads or a control intervention, designed to maintain usual fatty acid intake. Dietary intake was assessed at 18 months by 3-day weighed food record and at 3 years by food frequency questionnaire. Plasma phospholipids were measured at both time points. Associations were tested by regression. N-3 PUFA intake from background diet did not significantly affect plasma n-3 levels. In contrast, n-6 PUFA intake in background diet was positively related to plasma n-6 levels in both study groups. In addition, n-6 PUFA intake from diet was negatively associated with plasma n-3 levels at 18 months and 3 years (-0.16%/g n-6 intake, 95%CI -0.29 to -0.03 and -0.05%/g n-6 intake, 95%CI -0.09 to -0.01, respectively) in the active group, but not in the control group. Interventions intending to increase plasma n-3 PUFA in children by n-3 supplementation should also minimise n-6 PUFA intake in the background diet.
Development of Atmospheric Air 85Kr Monitoring Methodology on the Territory of the USSR
NASA Astrophysics Data System (ADS)
Pakhomov, Sergei; Dubasov, Yury
2014-05-01
Highly sensitive, low-background and high-performance method of beta-radioactivity measurements of the gas samples was developed in mid-eighties at Khlopin Radium institute. This method was based on the use of the serial automated installation for liquid scintillation measurements and special scintillating cells. Cells were equipped with the gas valve, and their internal surface were covered by a thin layer of organic scintillator. This method found was successfully was applied for 85Kr activity measurements in atmospheric krypton samples and for 85Kr concentration measurements in atmospheric air. For the first time, method developed for 85Kr activity measurements, was practically tested in May - June, 1986, while studying radioactive pollution characteristics in the air basin of Russia and Ukraine after the Chernobyl NPP accident. Thus for sampling of atmospheric krypton the industrial krypton-xenon mix manufactured at air-separating plants, located in the cities of Cherepovets, Lipetsk, Krivoi Rog and Enakiyevo was used. In the end of April and in the first half of May it was determined that 1,5-fold excess concentrations of 85Kr in atmospheric air were observed in atmospheric air of considerable part of the European territory of Russia and Ukraine During the period from 1987 to 1991 this method was used for monitoring of 85Kr on the territory of the former USSR in the air basin of Russia, Ukraine and Kazakhstan. Industrial krypton-xenon mix manufactured at 14 large air-separating plants was also used for sampling. Six of them were situated in Russia (Novomoskovsk, Lipetsk, Cherepovets, Chelyabinsk, Nizhni Tagil, Orsk). Seven - in Ukraine (Enakiyevo, Kommunarsk, Krivoi Rog, Makeyevka, Mariupol, Severodonetsk, Dneprodzerzhinsk). One plant was situated in Temirtau, in Kazakhstan. The analysis indicated that in Krivoi Rog; Dneprozhzerzhinsk; Severodonetsk; Makeyevka; Mariupol; Enakiyevo; Kommunarsk; Novomoskovsk and Cherepovets the average 85Kr concentration in atmospheric air was close to background level during monitoring. But in Lipetsk; Orsk; Nizhni Tagil and Temirtau 10-20% excess of background level was systematically observed. In Chelyabinsk concentration of 85Kr steadily exceeded this level by 2-3 times, and incidentally exceeded it for order. Generally, during this period about 1500 values of concentration 85Kr were obtained. Actually, the large-scale monitoring system of atmospheric 85Kr with a binding of sampling points to 14 air-separating plants covered the territory 1000 x 3000 km was created. The developed method of 85Kr activity measurement was successfully applied also when carrying out expedition works in Northern Atlantic during the period from 1987 to 1994 with use o ZIF-1000 cryogenic installation for sampling, which initially was intended for liquid nitrogen manufacturing at the ship. Generally, 80 measurements of 85Kr concentration were obtained using this method. It was determined, that the average concentration of 85Kr in atmospheric air in the open regions of the Atlantic Ocean, were close to background level during monitoring. The concentrations of 85Kr steadily exceeded this level by 2-3 times in English Channel, and incidentally exceeded it in tens times.
Rakhmanin, Yu A; Stekhin, A A; Yakovleva, G V; Karasev, A K; Marasanov, A V; Iksanova, T I; Ryabikov, V V
2015-01-01
In the paper there is evaluated the relationship of features of electronic state of the environment with a level of chronic, noninfectious diseases (CNID) in the regions of Russia, obtained on the basis of the monitoring measurements of the intensity of natural background electronic Bose condensate (BEBC) of natural ecosystems in a number of Russian regions and seas of the Arctic Ocean. The assessment of BEBC was implemented on results of measurements of redox state of distilled water being in the contact with natural water. The equilibrium redox state of distilled water, determined by the influx of electrons (quantum reduction) outside, is proportional to the intensity of BEBC. The obtained data attest to an increase in the intensity of the background of EBC in Siberia regions and, especially, within the limits ofwaters of Lake Baikal (the redox potential of the surface water in the lake ~ -70mV). Also there is observed a strong dependence of the background EBC in the latitudinal direction. Low levels of background EBC were noted in the Arkhangelsk region and the north-eastern Chukotka. Functioning of international systems of plasma sounding of ionosphere (such systems as HAARP) were established to have a detrimental effect on the background EBC in these regions. According to the results of measurements of the relative values of intensities of natural background of Bose condensate of electrons there was constructed the dependence reflecting the relationship of the prevalence of noninfectious diseases in the regions of Russia with the redox state of distilled water which can be characterized as a significant (regression coefficient R2 = 0.78). The relationship between noninfectious diseases (NID, %) with the intensity of the background of EBC (Ib rel. units) is estimated by the equation: NID [%] = 0.24Eh [mV]-25, where Eh ~ I/Ib. Numerical evaluations show that an increase in the biosphere redox potential of water by 90mV leads to an increase of the primary incidence by 20% (relatively to the average values for Russia). Analysis of results attests to the relationship of CNID with the electrophysical state of the environment that allows from different positions to arrive to true causes of their emergence, associated with changes in the electrophysical conditions of habitation and human activities that lead to the nascency of cellular metabolic disturbances.
Metabolic and Respiratory Costs of Increasing Song Amplitude in Zebra Finches
Zollinger, Sue Anne; Goller, Franz; Brumm, Henrik
2011-01-01
Bird song is a widely used model in the study of animal communication and sexual selection, and several song features have been shown to reflect the quality of the singer. Recent studies have demonstrated that song amplitude may be an honest signal of current condition in males and that females prefer high amplitude songs. In addition, birds raise the amplitude of their songs to communicate in noisy environments. Although it is generally assumed that louder song should be more costly to produce, there has been little empirical evidence to support this assumption. We tested the assumption by measuring oxygen consumption and respiratory patterns in adult male zebra finches (Taeniopygia guttata) singing at different amplitudes in different background noise conditions. As background noise levels increased, birds significantly increased the sound pressure level of their songs. We found that louder songs required significantly greater subsyringeal air sac pressure than quieter songs. Though increased pressure is probably achieved by increasing respiratory muscle activity, these increases did not correlate with measurable increases in oxygen consumption. In addition, we found that oxygen consumption increased in higher background noise, independent of singing behaviour. This observation supports previous research in mammals showing that high levels of environmental noise can induce physiological stress responses. While our study did not find that increasing vocal amplitude increased metabolic costs, further research is needed to determine whether there are other non-metabolic costs of singing louder or costs associated with chronic noise exposure. PMID:21915258
Soils: man-caused radioactivity and radiation forecast
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gablin, Vassily
2007-07-01
Available in abstract form only. Full text of publication follows: One of the main tasks of the radiation safety guarantee is non-admission of the excess over critical radiation levels. In Russia they are man-caused radiation levels. Meanwhile any radiation measurement represents total radioactivity. That is why it is hard to assess natural and man-caused contributions to total radioactivity. It is shown that soil radioactivity depends on natural factors including radioactivity of rocks and cosmic radiation as well as man-caused factors including nuclear and non-nuclear technologies. Whole totality of these factors includes unpredictable (non-deterministic) factors - nuclear explosions and radiation accidents,more » and predictable ones (deterministic) - all the rest. Deterministic factors represent background radioactivity whose trends is the base of the radiation forecast. Non-deterministic factors represent man-caused radiation treatment contribution which is to be controlled. This contribution is equal to the difference in measured radioactivity and radiation background. The way of calculation of background radioactivity is proposed. Contemporary soils are complicated technologically influenced systems with multi-leveled spatial and temporary inhomogeneity of radionuclides distribution. Generally analysis area can be characterized by any set of factors of soil radioactivity including natural and man-caused factors. Natural factors are cosmic radiation and radioactivity of rocks. Man-caused factors are shown on Fig. 1. It is obvious that man-caused radioactivity is due to both artificial and natural emitters. Any result of radiation measurement represents total radioactivity i.e. the sum of activities resulting from natural and man-caused emitters. There is no gauge which could separately measure natural and man-caused radioactivity. That is why it is so hard to assess natural and man-caused contributions to soil radioactivity. It would have been possible if human activity had led to contamination of soil only by artificial radionuclides. But we can view a totality of soil radioactivity factors in the following way. (author)« less
Sources of atmospheric aerosols controlling PM10 levels in Heraklion, Crete during winter time
NASA Astrophysics Data System (ADS)
Kalivitis, Nikolaos; Kouvarakis, Giorgos; Stavroulas, Iasonas; Kandilogiannaki, Maria; Vavadaki, Katerina; Mihalopoulos, Nikolaos
2016-04-01
High concentrations of Particulate Matter (PM) in the atmosphere have negative impact to human health. Thresholds for ambient concentrations that are defined by the directive 2008/50/EC are frequently exceeded even at background conditions in the Mediterranean region as shown in earlier studies. The sources of atmospheric particles in the urban environment of a medium size city of eastern Mediterranean are studied in the present work in order to better understand the causes and characteristics of exceedances of the daily mean PM10limit value of 50 μg m-3. Measurements were performed at the atmospheric quality measurement station of the Region of Crete, at the Heraklion city center on Crete island, during the winter/spring period of 2014-2015 and 2015-2016. Special emphasis was given to the study of the contribution of Black Carbon (BC) to the levels of PM10. Continuous measurements were performed using a beta-attenuation PM10monitor and a 7-wavelength Aethalometer with a time resolution of 30 and 5 minutes respectively. For direct comparison to background regional conditions, concurrent routine measurements at the atmospheric research station of University of Crete at Finokalia were used as background reference. Analysis of exceedances in the daily PM10 mass concentration showed that the total of the exceedances was related to long range transport of Saharan dust rather than local sources. However, compared to the Finokalia station it was found that there were 20% more exceedances in Heraklion, the addition of transported dust on the local pollution was the reason for the additional exceedance days. Excluding dust events, it was found that the PM10variability was dependent on the BC abundance, traffic during rush hours in the morning and biomass burning for domestic heating in the evening contributed significantly to PM10levels in Heraklion.
Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro
2016-01-01
Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.
Williams, Richard M.; Aalseth, C. E.; Brandenberger, J. M.; ...
2017-02-17
Here, this paper describes the generation of 39Ar, via reactor irradiation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield two calibration standards that are respectively 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory's shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50 × 39Ar in P10 standard is 3.6% (k=2).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Richard M.; Aalseth, C. E.; Brandenberger, J. M.
Here, this paper describes the generation of 39Ar, via reactor irradiation of potassium carbonate, followed by quantitative analysis (length-compensated proportional counting) to yield two calibration standards that are respectively 50 and 3 times atmospheric background levels. Measurements were performed in Pacific Northwest National Laboratory's shallow underground counting laboratory studying the effect of gas density on beta-transport; these results are compared with simulation. The total expanded uncertainty of the specific activity for the ~50 × 39Ar in P10 standard is 3.6% (k=2).
Application of Compton-suppressed self-induced XRF to spent nuclear fuel measurement
NASA Astrophysics Data System (ADS)
Park, Se-Hwan; Jo, Kwang Ho; Lee, Seung Kyu; Seo, Hee; Lee, Chaehun; Won, Byung-Hee; Ahn, Seong-Kyu; Ku, Jeong-Hoe
2017-11-01
Self-induced X-ray fluorescence (XRF) is a technique by which plutonium (Pu) content in spent nuclear fuel can be directly quantified. In the present work, this method successfully measured the plutonium/uranium (Pu/U) peak ratio of a pressurized water reactor (PWR)'s spent nuclear fuel at the Korea atomic energy research institute (KAERI)'s post irradiation examination facility (PIEF). In order to reduce the Compton background in the low-energy X-ray region, the Compton suppression system additionally was implemented. By use of this system, the spectrum's background level was reduced by a factor of approximately 2. This work shows that Compton-suppressed selfinduced XRF can be effectively applied to Pu accounting in spent nuclear fuel.
Environmental background levels of Pb were measured in ponds, river waters, sediments, suspended sediments, rocks, and air particulates within the Kankakee watershed during the period of 1995 to 1999. Stable isotopic Pb distinguised airborne Pb and its incorporation into riverin...
Mathematics Course Placement Using Holistic Measures: Possibilities for Community College Students
ERIC Educational Resources Information Center
Ngo, Federick; Chi, W. Edward; Park, Elizabeth So Yun
2018-01-01
Background/Context: Most community colleges across the country use a placement test to determine students' readiness for college-level coursework, yet these tests are admittedly imperfect instruments. Researchers have documented significant problems stemming from overreliance on placement testing, including placement error and misdiagnosis of…
Calculating background levels for ecological risk parameters in toxic harbor sediment
Leadon, C.J.; McDonnell, T.R.; Lear, J.; Barclift, D.
2007-01-01
Establishing background levels for biological parameters is necessary in assessing the ecological risks from harbor sediment contaminated with toxic chemicals. For chemicals in sediment, the term contaminated is defined as having concentrations above background and significant human health or ecological risk levels. For biological parameters, a site could be considered contaminated if levels of the parameter are either more or less than the background level, depending on the specific parameter. Biological parameters can include tissue chemical concentrations in ecological receptors, bioassay responses, bioaccumulation levels, and benthic community metrics. Chemical parameters can include sediment concentrations of a variety of potentially toxic chemicals. Indirectly, contaminated harbor sediment can impact shellfish, fish, birds, and marine mammals, and human populations. This paper summarizes the methods used to define background levels for chemical and biological parameters from a survey of ecological risk investigations of marine harbor sediment at California Navy bases. Background levels for regional biological indices used to quantify ecological risks for benthic communities are also described. Generally, background stations are positioned in relatively clean areas exhibiting the same physical and general chemical characteristics as nearby areas with contaminated harbor sediment. The number of background stations and the number of sample replicates per background station depend on the statistical design of the sediment ecological risk investigation, developed through the data quality objective (DQO) process. Biological data from the background stations can be compared to data from a contaminated site by using minimum or maximum background levels or comparative statistics. In Navy ecological risk assessments (ERA's), calculated background levels and appropriate ecological risk screening criteria are used to identify sampling stations and sites with contaminated sediments.
NASA Astrophysics Data System (ADS)
Verhulst, Kristal R.; Karion, Anna; Kim, Jooil; Salameh, Peter K.; Keeling, Ralph F.; Newman, Sally; Miller, John; Sloop, Christopher; Pongetti, Thomas; Rao, Preeti; Wong, Clare; Hopkins, Francesca M.; Yadav, Vineet; Weiss, Ray F.; Duren, Riley M.; Miller, Charles E.
2017-07-01
We report continuous surface observations of carbon dioxide (CO2) and methane (CH4) from the Los Angeles (LA) Megacity Carbon Project during 2015. We devised a calibration strategy, methods for selection of background air masses, calculation of urban enhancements, and a detailed algorithm for estimating uncertainties in urban-scale CO2 and CH4 measurements. These methods are essential for understanding carbon fluxes from the LA megacity and other complex urban environments globally. We estimate background mole fractions entering LA using observations from four extra-urban
sites including two marine
sites located south of LA in La Jolla (LJO) and offshore on San Clemente Island (SCI), one continental
site located in Victorville (VIC), in the high desert northeast of LA, and one continental/mid-troposphere
site located on Mount Wilson (MWO) in the San Gabriel Mountains. We find that a local marine background can be established to within ˜ 1 ppm CO2 and ˜ 10 ppb CH4 using these local measurement sites. Overall, atmospheric carbon dioxide and methane levels are highly variable across Los Angeles. Urban
and suburban
sites show moderate to large CO2 and CH4 enhancements relative to a marine background estimate. The USC (University of Southern California) site near downtown LA exhibits median hourly enhancements of ˜ 20 ppm CO2 and ˜ 150 ppb CH4 during 2015 as well as ˜ 15 ppm CO2 and ˜ 80 ppb CH4 during mid-afternoon hours (12:00-16:00 LT, local time), which is the typical period of focus for flux inversions. The estimated measurement uncertainty is typically better than 0.1 ppm CO2 and 1 ppb CH4 based on the repeated standard gas measurements from the LA sites during the last 2 years, similar to Andrews et al. (2014). The largest component of the measurement uncertainty is due to the single-point calibration method; however, the uncertainty in the background mole fraction is much larger than the measurement uncertainty. The background uncertainty for the marine background estimate is ˜ 10 and ˜ 15 % of the median mid-afternoon enhancement near downtown LA for CO2 and CH4, respectively. Overall, analytical and background uncertainties are small relative to the local CO2 and CH4 enhancements; however, our results suggest that reducing the uncertainty to less than 5 % of the median mid-afternoon enhancement will require detailed assessment of the impact of meteorology on background conditions.
Autophagy Signaling in Prostate Cancer: Identification of a Novel Phosphatase
2011-08-01
the transmembrane and cytosolic residues). We measured PTPRS activity using a phospho-tyrosine (pTyr) peptide with malachite green free phosphate...vitro using a 100 uM phosphotyrosine peptide substrate and malachite green detection of released free phosphates. Activity is expressed as picomoles...Upstate) at 37°C for 15 minutes. Released phosphates were detected with malachite green (Upstate) and absorbance measured at 650 nm. Background levels
ERIC Educational Resources Information Center
Thomas, Gregg; Douglass, John Aubrey
2009-01-01
Throughout the world, interest in gauging learning outcomes at all levels of education has grown considerably over the past decade. In higher education, measuring "learning outcomes" is viewed by many stakeholders as a relatively new method to judge the "value added" of colleges and universities. The potential to accurately…
Background Model for the Majorana Demonstrator
NASA Astrophysics Data System (ADS)
Cuesta, C.; Abgrall, N.; Aguayo, E.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Boswell, M.; Brudanin, V.; Busch, M.; Byram, D.; Caldwell, A. S.; Chan, Y.-D.; Christofferson, C. D.; Combs, D. C.; Detwiler, J. A.; Doe, P. J.; Efremenko, Yu.; Egorov, V.; Ejiri, H.; Elliott, S. R.; Fast, J. E.; Finnerty, P.; Fraenkle, F. M.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guiseppe, V. E.; Gusev, K.; Hallin, A. L.; Hazama, R.; Hegai, A.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Keeter, K. J.; Kidd, M. F.; Kochetov, O.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Leviner, L. E.; Loach, J. C.; MacMullin, J.; MacMullin, S.; Martin, R. D.; Meijer, S.; Mertens, S.; Nomachi, M.; Orrell, J. L.; O'Shaughnessy, C.; Overman, N. R.; Phillips, D. G.; Poon, A. W. P.; Pushkin, K.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Ronquest, M. C.; Schubert, A. G.; Shanks, B.; Shima, T.; Shirchenko, M.; Snavely, K. J.; Snyder, N.; Suriano, A. M.; Thompson, J.; Timkin, V.; Tornow, W.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Young, A. R.; Yu, C.-H.; Yumatov, V.
The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example using powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevelhimer, Mark S.; Deng, Z. Daniel; Scherelis, Constantin
2016-01-01
Underwater noise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels of different sizes and other underwater sound sources in both static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines onmore » the Mississippi River, where the sound of flowing water is included in background measurements. The size of vessels measured ranged from a small fishing boat with a 60 HP outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, and when compared to the sound created by an operating HK turbine were many times greater. A comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed values.« less
A technique for searching for the 2 K capture in 124Xe with a copper proportional counter
NASA Astrophysics Data System (ADS)
Gavrilyuk, Yu. M.; Gangapshev, A. M.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.
2015-12-01
An experimental technique for searching for the 2 K capture in 124Xe with a large low-background copper proportional counter is described. Such an experiment is conducted at the Baksan Neutrino Observatory of the Institute for Nuclear Research of the Russian Academy of Sciences. The experimental setup is located in the Low-Background Deep-Level Laboratory at a depth of 4900 m.w.e., where the flux of muons of cosmic rays is suppressed by a factor of 107 relative to that at the Earth's surface. The setup incorporates a proportional counter and low-background shielding (18 cm of copper, 15 cm of lead, and 8 cm of borated polyethylene). The results of processing the data obtained in 5 months of live measurement time are presented. A new limit on the half-life of 124Xe with respect to the 2 K capture is set at the level of 2.5 × 1021 years.
Meléndez-Martínez, Antonio J; Vicario, Isabel M; Heredia, Francisco J
2003-12-03
Tristimulus Colorimetry was applied to characterize the color of Valencia late orange juices. Color measurements were made against white background and black background. The profile of the main carotenoids related to the color of the juices was determined by HPLC. Significant correlations (p < 0.05) between b*, Cab* and h(ab) and the content of beta-cryptoxanthin, lutein + zeaxanthin and beta-carotene were found. The correlations between the color parameters L*, a*, b*, Cab* and h(ab) and the carotenoids content were also explored by partial least squares. The results obtained have shown that it is possible to obtain equations, by means of multiple regression models, which allow the determination of the individual carotenoid levels from the CIELAB color parameters, with R2 values always over 0.9. In this sense, equations have been proposed to calculate the retinol equivalents (1 RE = 1 microgram retinol = 12 micrograms beta-carotene = 24 micrograms alpha-carotene = 24 micrograms beta-cryptoxanthin) of the orange juice analyzed as a function of the color parameters calculated from measurement made against white and black backgrounds. The average RE per liter of juice obtained by HPLC was 51.07 +/- 18.89, whereas employing these equations, average RE values obtained were 51.16 +/- 1.36 and 51.21 +/- 1.70 for white background and black background, respectively.
New Jersey Radium Research Project: final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharpe, W.D.
1979-01-01
Cancers among dead New Jersey subjects were almost three times the expected number. Their radiation experience apparently acted as a generalized carcinogen. Conventional clinical, laboratory and roentgenographic tests neither correlated with calculated radiation exposure nor predicted which subjects subsequently developed cancer. More subjects than expected were deaf and enough of the subjects had increased erythrocyte sedimentation rates and decreased alpha-1 serum globulin levels that both hearing tests and tests of immune competence should be undertaken among asymptomatic exposed populations at regular intervals to see whether these may indicate radiation effects prior to a fatal cancer or blood dyscrasia. If pre-terminalmore » radium-226 burdens validly express total irradiation experience, and past exposure to shorter-lived radium-228 (mesothorium) makes it unlikely that this is so, the distribution of radium osteitis among our subjects suggests that anatomically demonstrable radiation injury occurs in the vast majority of subjects with any radium-226 burden that can be measured above background levels after twenty-five years, and in almost half of those exposed whose measured radium-226 burdens are indistinguishable from background levels. Modification of the occupational exposure standard is recommended. (PCS)« less
Method for technology-delivered healthcare measures.
Kramer-Jackman, Kelli Lee; Popkess-Vawter, Sue
2011-12-01
Current healthcare literature lacks development and evaluation methods for research and practice measures administered by technology. Researchers with varying levels of informatics experience are developing technology-delivered measures because of the numerous advantages they offer. Hasty development of technology-delivered measures can present issues that negatively influence administration and psychometric properties. The Method for Technology-delivered Healthcare Measures is designed to systematically guide the development and evaluation of technology-delivered measures. The five-step Method for Technology-delivered Healthcare Measures includes establishment of content, e-Health literacy, technology delivery, expert usability, and participant usability. Background information and Method for Technology-delivered Healthcare Measures steps are detailed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gillis, Jessica M.; Whicker, Jeffrey J.
2016-01-26
Three separate Sampling and Analysis Plans (SAPs) were prepared for tracts C-2, C-3, and C-4. The objective of sampling was to confirm, within the stated statistical confidence limits, that the mean levels of potential radioactive residual contamination in soils in the C Tracts are documented, in appropriate units, and are below the 15 mrem/y (150 μSv/y) Screening Action Levels (SALs). Results show that radionuclide concentration upper-bound 95% confidence levels were close to background levels, with the exception of Pu-239 and Cs-137 being slightly elevated above background, and all measurements were below the ALs and meet the real property release criteriamore » for future construction or recreational use. A follow-up ALARA analysis showed that the costs of cleanup of the soil in areas of elevated concentration and confirmatory sampling would far exceed any benefit from dose reduction.« less
Hosseini Pooya, SM; Orouji, T
2014-01-01
Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. Method: These sources are included; inhomogeneity of TLDs sensitivity, variability of TLD readings due to limited sensitivity and background, energy dependence, directional dependence, non-linearity of the response, fading, dependent on ambient temperature / humidity and calibration errors, which may affect on the dose responses. Some parameters which influence on the above sources of uncertainty are studied for Harshaw TLD-100 cards dosimeters as well as the hot gas Harshaw 6600 TLD reader system. Results: The individual uncertainties of each sources was measured less than 6.7% in 68% confidence level. The total uncertainty was calculated 17.5% with 95% confidence level. Conclusion: The TLD-100 personal dosimeters as well as the Harshaw TLD-100 reader 6600 system show the total uncertainty value which is less than that of admissible value of 42% for personal dosimetry services. PMID:25505769
Influence of background size, luminance and eccentricity on different adaptation mechanisms
Gloriani, Alejandro H.; Matesanz, Beatriz M.; Barrionuevo, Pablo A.; Arranz, Isabel; Issolio, Luis; Mar, Santiago; Aparicio, Juan A.
2016-01-01
Mechanisms of light adaptation have been traditionally explained with reference to psychophysical experimentation. However, the neural substrata involved in those mechanisms remain to be elucidated. Our study analyzed links between psychophysical measurements and retinal physiological evidence with consideration for the phenomena of rod-cone interactions, photon noise, and spatial summation. Threshold test luminances were obtained with steady background fields at mesopic and photopic light levels (i.e., 0.06–110 cd/m2) for retinal eccentricities from 0° to 15° using three combinations of background/test field sizes (i.e., 10°/2°, 10°/0.45°, and 1°/0.45°). A two-channel Maxwellian view optical system was employed to eliminate pupil effects on the measured thresholds. A model based on visual mechanisms that were described in the literature was optimized to fit the measured luminance thresholds in all experimental conditions. Our results can be described by a combination of visual mechanisms. We determined how spatial summation changed with eccentricity and how subtractive adaptation changed with eccentricity and background field size. According to our model, photon noise plays a significant role to explain contrast detection thresholds measured with the 1/0.45° background/test size combination at mesopic luminances and at off-axis eccentricities. In these conditions, our data reflect the presence of rod-cone interaction for eccentricities between 6° and 9° and luminances between 0.6 and 5 cd/m2. In spite of the increasing noise effects with eccentricity, results also show that the visual system tends to maintain a constant signal-to-noise ratio in the off-axis detection task over the whole mesopic range. PMID:27210038
Influence of background size, luminance and eccentricity on different adaptation mechanisms.
Gloriani, Alejandro H; Matesanz, Beatriz M; Barrionuevo, Pablo A; Arranz, Isabel; Issolio, Luis; Mar, Santiago; Aparicio, Juan A
2016-08-01
Mechanisms of light adaptation have been traditionally explained with reference to psychophysical experimentation. However, the neural substrata involved in those mechanisms remain to be elucidated. Our study analyzed links between psychophysical measurements and retinal physiological evidence with consideration for the phenomena of rod-cone interactions, photon noise, and spatial summation. Threshold test luminances were obtained with steady background fields at mesopic and photopic light levels (i.e., 0.06-110cd/m(2)) for retinal eccentricities from 0° to 15° using three combinations of background/test field sizes (i.e., 10°/2°, 10°/0.45°, and 1°/0.45°). A two-channel Maxwellian view optical system was employed to eliminate pupil effects on the measured thresholds. A model based on visual mechanisms that were described in the literature was optimized to fit the measured luminance thresholds in all experimental conditions. Our results can be described by a combination of visual mechanisms. We determined how spatial summation changed with eccentricity and how subtractive adaptation changed with eccentricity and background field size. According to our model, photon noise plays a significant role to explain contrast detection thresholds measured with the 1/0.45° background/test size combination at mesopic luminances and at off-axis eccentricities. In these conditions, our data reflect the presence of rod-cone interaction for eccentricities between 6° and 9° and luminances between 0.6 and 5cd/m(2). In spite of the increasing noise effects with eccentricity, results also show that the visual system tends to maintain a constant signal-to-noise ratio in the off-axis detection task over the whole mesopic range. Copyright © 2016 Elsevier Ltd. All rights reserved.
An ultra-low background PMT for liquid xenon detectors
Akerib, D. S.; Bai, X.; Bernard, E.; ...
2012-11-15
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / < 8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of xmore » $$\\frac{1}{24}$$ 238U / x $$\\frac{1}{9}$$ 232Th / x $$\\frac{1}{8}$$ 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of x $$\\frac{1}{25}$$ after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \\times $$\\frac{1}{36}$$. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.« less
Workplace exposure to nanoparticles from gas metal arc welding process
NASA Astrophysics Data System (ADS)
Zhang, Meibian; Jian, Le; Bin, Pingfan; Xing, Mingluan; Lou, Jianlin; Cong, Liming; Zou, Hua
2013-11-01
Workplace exposure to nanoparticles from gas metal arc welding (GMAW) process in an automobile manufacturing factory was investigated using a combination of multiple metrics and a comparison with background particles. The number concentration (NC), lung-deposited surface area concentration (SAC), estimated SAC and mass concentration (MC) of nanoparticles produced from the GMAW process were significantly higher than those of background particles before welding ( P < 0.01). A bimodal size distribution by mass for welding particles with two peak values (i.e., 10,000-18,000 and 560-320 nm) and a unimodal size distribution by number with 190.7-nm mode size or 154.9-nm geometric size were observed. Nanoparticles by number comprised 60.7 % of particles, whereas nanoparticles by mass only accounted for 18.2 % of the total particles. The morphology of welding particles was dominated by the formation of chain-like agglomerates of primary particles. The metal composition of these welding particles consisted primarily of Fe, Mn, and Zn. The size distribution, morphology, and elemental compositions of welding particles were significantly different from background particles. Working activities, sampling distances from the source, air velocity, engineering control measures, and background particles in working places had significant influences on concentrations of airborne nanoparticle. In addition, SAC showed a high correlation with NC and a relatively low correlation with MC. These findings indicate that the GMAW process is able to generate significant levels of nanoparticles. It is recommended that a combination of multiple metrics is measured as part of a well-designed sampling strategy for airborne nanoparticles. Key exposure factors, such as particle agglomeration/aggregation, background particles, working activities, temporal and spatial distributions of the particles, air velocity, engineering control measures, should be investigated when measuring workplace exposure to nanoparticles.
LoCuSS: weak-lensing mass calibration of galaxy clusters
NASA Astrophysics Data System (ADS)
Okabe, Nobuhiro; Smith, Graham P.
2016-10-01
We present weak-lensing mass measurements of 50 X-ray luminous galaxy clusters at 0.15 ≤ z ≤ 0.3, based on uniform high-quality observations with Suprime-Cam mounted on the 8.2-m Subaru telescope. We pay close attention to possible systematic biases, aiming to control them at the ≲4 per cent level. The dominant source of systematic bias in weak-lensing measurements of the mass of individual galaxy clusters is contamination of background galaxy catalogues by faint cluster and foreground galaxies. We extend our conservative method for selecting background galaxies with (V - I') colours redder than the red sequence of cluster members to use a colour-cut that depends on cluster-centric radius. This allows us to define background galaxy samples that suffer ≤1 per cent contamination, and comprise 13 galaxies per square arcminute. Thanks to the purity of our background galaxy catalogue, the largest systematic that we identify in our analysis is a shape measurement bias of 3 per cent, that we measure using simulations that probe weak shears up to g = 0.3. Our individual cluster mass and concentration measurements are in excellent agreement with predictions of the mass-concentration relation. Equally, our stacked shear profile is in excellent agreement with the Navarro Frenk and White profile. Our new Local Cluster Substructure Survey mass measurements are consistent with the Canadian Cluster Cosmology Project and Cluster Lensing And Supernova Survey with Hubble surveys, and in tension with the Weighing the Giants at ˜1σ-2σ significance. Overall, the consensus at z ≤ 0.3 that is emerging from these complementary surveys represents important progress for cluster mass calibration, and augurs well for cluster cosmology.
An evaluation of Space Shuttle STS-2 payload bay acoustic data and comparison with predictions
NASA Technical Reports Server (NTRS)
Wilby, J. F.; Piersol, A. G.; Wilby, E. G.
1982-01-01
Space average sound pressure levels computed from measurements at 18 locations in the payload bay of the Space Shuttle orbiter vehicle during the STS-2 launch were compared with predicted levels obtained using the PACES computer program. The comparisons were performed over the frequency range 12.5 Hz to 1000 Hz, since the test data at higher frequencies are contaminated by instrumentation background noise. In general the PACES computer program tends to overpredict the space average sound levels in the payload bay, although the magnitude of the discrepancy is usually small. Furthermore the discrepancy depends to some extent on the manner in which the payload is modeled analytically, and the method used to determine the "measured' space average sound pressure levels. Thus the difference between predicted and measured sound levels, averaged over the 20 one third octave bands from 12.5 Hz to 1000 Hz, varies from 1 dB to 3.5 dB.
Radiometric spectral and band rendering of targets using anisotropic BRDFs and measured backgrounds
NASA Astrophysics Data System (ADS)
Hilgers, John W.; Hoffman, Jeffrey A.; Reynolds, William R.; Jafolla, James C.
2000-07-01
Achievement of ultra-high fidelity signature modeling of targets requires a significant level of complexity for all of the components required in the rendering process. Specifically, the reflectance of the surface must be described using the bi-directional distribution function (BRDF). In addition, the spatial representation of the background must be high fidelity. A methodology and corresponding model for spectral and band rendering of targets using both isotropic and anisotropic BRDFs is presented. In addition, a set of tools will be described for generating theoretical anisotropic BRDFs and for reducing data required for a description of an anisotropic BRDF by 5 orders of magnitude. This methodology is hybrid using a spectrally measured panoramic of the background mapped to a large hemisphere. Both radiosity and ray-tracing approaches are incorporated simultaneously for a robust solution. In the thermal domain the spectral emission is also included in the solution. Rendering examples using several BRDFs will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leder, A.; Anderson, A. J.; Billard, J.
2017-10-02
The Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering using dark-matter-style detectors with sub-keV thresholds placed near a neutrino source, such as the MIT (research) Reactor (MITR), which operates at 5.5 MW generating approximately 2.2e18 neutrinos/second at the core. Currently, Ricochet is characterizing the backgrounds at MITR, the main component of which comes in the form of neutrons emitted from the core simultaneous with the neutrino signal. To characterize this background, we wrapped a Bonner cylinder around a He-3 thermal neutron detector, whose data was then unfolded to produce a neutron energy spectrum across several orders of magnitude.more » We discuss the resulting spectrum and its implications for deploying Ricochet in the future at the MITR site as well as the feasibility of reducing this background level via the addition of polyethylene shielding around the detector setup.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Y; Souri, S; Gill, G
Purpose: To statistically determine the optimal tolerance level in the verification of delivery dose compared to the planned dose in an in vivo dosimetry system in radiotherapy. Methods: The LANDAUER MicroSTARii dosimetry system with screened nanoDots (optically stimulated luminescence dosimeters) was used for in vivo dose measurements. Ideally, the measured dose should match with the planned dose and falls within a normal distribution. Any deviation from the normal distribution may be redeemed as a mismatch, therefore a potential sign of the dose misadministration. Randomly mis-positioned nanoDots can yield a continuum background distribution. A percentage difference of the measured dose tomore » its corresponding planned dose (ΔD) can be used to analyze combined data sets for different patients. A model of a Gaussian plus a flat function was used to fit the ΔD distribution. Results: Total 434 nanoDot measurements for breast cancer patients were collected across a period of three months. The fit yields a Gaussian mean of 2.9% and a standard deviation (SD) of 5.3%. The observed shift of the mean from zero is attributed to the machine output bias and calibration of the dosimetry system. A pass interval of −2SD to +2SD was applied and a mismatch background was estimated to be 4.8%. With such a tolerance level, one can expect that 99.99% of patients should pass the verification and at most 0.011% might have a potential dose misadministration that may not be detected after 3 times of repeated measurements. After implementation, a number of new start breast cancer patients were monitored and the measured pass rate is consistent with the model prediction. Conclusion: It is feasible to implement an optimal tolerance level in order to maintain a low limit of potential dose misadministration while still to keep a relatively high pass rate in radiotherapy delivery verification.« less
Vitamin K metabolism in a rat model of chronic kidney disease
USDA-ARS?s Scientific Manuscript database
Background: Patients with chronic kidney disease (CKD) have very high levels of uncarboxylated, inactive, extra-hepatic vitamin K-dependent proteins measured in circulation, putting them at risk for complications of vitamin K deficiency. The major form of vitamin K found in the liver is phylloquinon...
School Security and Student Misbehavior: A Multi-Level Examination
ERIC Educational Resources Information Center
Servoss, Timothy J.
2017-01-01
Despite a nationwide trend to increase security measures in schools, their effectiveness in reducing or preventing student misbehavior remains largely unexamined. In addition, there is concern that increased security may have unintended negative side effects and is applied inequitably across students of disparate racial/ethnic backgrounds. The…
ERIC Educational Resources Information Center
Perez-Smith, Alina; Spirito, Anthony; Boergers, Julie
2002-01-01
Adolescents (N=48) who attempted suicide were administered measures of hopelessness and depression. Those living in neighborhoods with weak social networks reported higher levels of hopelessness, even after controlling for socioeconomic backgrounds and depression. Findings suggest that the environmental context may play a role in the emotional…
pH & Rate of Enzymatic Reactions.
ERIC Educational Resources Information Center
Clariana, Roy B.
1991-01-01
A quantitative and inexpensive way to measure the rate of enzymatic reaction is provided. The effects of different pH levels on the reaction rate of an enzyme from yeast are investigated and the results graphed. Background information, a list of needed materials, directions for preparing solutions, procedure, and results and discussion are…
Parks, David R; El Khettabi, Faysal; Chase, Eric; Hoffman, Robert A; Perfetto, Stephen P; Spidlen, Josef; Wood, James C S; Moore, Wayne A; Brinkman, Ryan R
2017-03-01
We developed a fully automated procedure for analyzing data from LED pulses and multilevel bead sets to evaluate backgrounds and photoelectron scales of cytometer fluorescence channels. The method improves on previous formulations by fitting a full quadratic model with appropriate weighting and by providing standard errors and peak residuals as well as the fitted parameters themselves. Here we describe the details of the methods and procedures involved and present a set of illustrations and test cases that demonstrate the consistency and reliability of the results. The automated analysis and fitting procedure is generally quite successful in providing good estimates of the Spe (statistical photoelectron) scales and backgrounds for all the fluorescence channels on instruments with good linearity. The precision of the results obtained from LED data is almost always better than that from multilevel bead data, but the bead procedure is easy to carry out and provides results good enough for most purposes. Including standard errors on the fitted parameters is important for understanding the uncertainty in the values of interest. The weighted residuals give information about how well the data fits the model, and particularly high residuals indicate bad data points. Known photoelectron scales and measurement channel backgrounds make it possible to estimate the precision of measurements at different signal levels and the effects of compensated spectral overlap on measurement quality. Combining this information with measurements of standard samples carrying dyes of biological interest, we can make accurate comparisons of dye sensitivity among different instruments. Our method is freely available through the R/Bioconductor package flowQB. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
Estimation of neutron spectrum in the low-level gamma spectroscopy system using unfolding procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knežević, D., E-mail: david.knezevic@df.uns.ac.rs; Jovančević, N.; Krmar, M.
2016-03-25
The radiation resulting from neutron interactions with Ge nuclei in active volume of HPGe detectors is one of the main concerns in low-level gamma spectroscopy measurements [1,2]. It is usually not possible to measure directly spectrum of neutrons which strike detector. This paper explore the possibility of estimation of neutron spectrum using measured activities of certain Ge(n,γ) and Ge(n,n’) reactions (obtained from low-level gamma measurements), available ENDF cross section data and unfolding procedures. In this work HPGe detector with passive shield made from commercial low background lead was used for the measurement. The most important objective of this study wasmore » to reconstruct muon induced neutron spectrum created in the shield of the HPGe detector. MAXED [3] and GRAVEL [4] algorithms for neutron spectra unfolding were used. The results of those two algorithms were compared and we analyzed the sensitivity of the unfolding procedure to the various input parameters.« less
Achilleos, Souzana; Evans, John S; Yiallouros, Panayiotis K; Kleanthous, Savvas; Schwartz, Joel; Koutrakis, Petros
2014-12-01
Air quality in Cyprus is influenced by both local and transported pollution, including desert dust storms. We examined PM10 concentration data collected in Nicosia (urban representative) from April 1, 1993, through December 11, 2008, and in Ayia Marina (rural background representative) from January 1, 1999, through December 31, 2008. Measurements were conducted using a Tapered Element Oscillating Micro-balance (TEOM). PM10 concentrations, meteorological records, and satellite data were used to identify dust storm days. We investigated long-term trends using a Generalized Additive Model (GAM) after controlling for day of week, month, temperature, wind speed, and relative humidity. In Nicosia, annual PM10 concentrations ranged from 50.4 to 63.8 μg/m3 and exceeded the EU annual standard limit enacted in 2005 of 40 μg/m3 every year A large, statistically significant impact of urban sources (defined as the difference between urban and background levels) was seen in Nicosia over the period 2000-2008, and was highest during traffic hours, weekdays, cold months, and low wind conditions. Our estimate of the mean (standard error) contribution of urban sources to the daily ambient PM10 was 24.0 (0.4) μg/m3. The study of yearly trends showed that PM10 levels in Nicosia decreased from 59.4 μg/m3 in 1993 to 49.0 μg/m3 in 2008, probably in part as a result of traffic emission control policies in Cyprus. In Ayia Marina, annual concentrations ranged from 27.3 to 35.6 μg/m3, and no obvious time trends were observed. The levels measured at the Cyprus background site are comparable to background concentrations reported in other Eastern Mediterranean countries. Average daily PM10 concentrations during desert dust storms were around 100 μg/m3 since 2000 and much higher in earlier years. Despite the large impact ofdust storms and their increasing frequency over time, dust storms were responsible for a small fraction of the exceedances of the daily PM10 limit. Implications: This paper examines PM10 concentrations in Nicosia, Cyprus, from 1993 to 2008. The decrease in PM10 levels in Nicosia suggests that the implementation of traffic emission control policies in Cyprus has been effective. However, particle levels still exceeded the European Uion annual standard, and dust storms were responsible for a small fraction of the daily PM10 limit exceedances. Other natural particles that are not assessed in this study, such as resuspended soil and sea salt, may be responsible in part for the hig particle levels.
Omori, Yasutaka; Tokonami, Shinji; Sahoo, Sarata Kumar; Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Hosoda, Masahiro; Kudo, Hiromi; Pornnumpa, Chanis; Nair, Raghu Ram K; Jayalekshmi, Padmavaty Amma; Sebastian, Paul; Akiba, Suminori
2017-03-20
In order to evaluate internal exposure to radon and thoron, concentrations for radon, thoron, and thoron progeny were measured for 259 dwellings located in high background radiation areas (HBRAs, outdoor external dose: 3-5 mGy y -1 ) and low background radiation areas (control areas, outdoor external dose: 1 mGy y -1 ) in Karunagappally Taluk, Kerala, India. The measurements were conducted using passive-type radon-thoron detectors and thoron progeny detectors over two six-month measurement periods from June 2010 to June 2011. The results showed no major differences in radon and thoron progeny concentrations between the HBRAs and the control areas. The geometric mean of the annual effective dose due to radon and thoron was calculated as 0.10 and 0.44 mSv, respectively. The doses were small, but not negligible compared with the external dose in the two areas.
Oh, Yoonbae; Park, Cheonho; Kim, Do Hyoung; Shin, Hojin; Kang, Yu Min; DeWaele, Mark; Lee, Jeyeon; Min, Hoon-Ki; Blaha, Charles D; Bennet, Kevin E; Kim, In Young; Lee, Kendall H; Jang, Dong Pyo
2016-11-15
Dopamine (DA) modulates central neuronal activity through both phasic (second to second) and tonic (minutes to hours) terminal release. Conventional fast-scan cyclic voltammetry (FSCV), in combination with carbon fiber microelectrodes, has been used to measure phasic DA release in vivo by adopting a background subtraction procedure to remove background capacitive currents. However, measuring tonic changes in DA concentrations using conventional FSCV has been difficult because background capacitive currents are inherently unstable over long recording periods. To measure tonic changes in DA concentrations over several hours, we applied a novel charge-balancing multiple waveform FSCV (CBM-FSCV), combined with a dual background subtraction technique, to minimize temporal variations in background capacitive currents. Using this method, in vitro, charge variations from a reference time point were nearly zero for 48 h, whereas with conventional background subtraction, charge variations progressively increased. CBM-FSCV also demonstrated a high selectivity against 3,4-dihydroxyphenylacetic acid and ascorbic acid, two major chemical interferents in the brain, yielding a sensitivity of 85.40 ± 14.30 nA/μM and limit of detection of 5.8 ± 0.9 nM for DA while maintaining selectivity. Recorded in vivo by CBM-FSCV, pharmacological inhibition of DA reuptake (nomifensine) resulted in a 235 ± 60 nM increase in tonic extracellular DA concentrations, while inhibition of DA synthesis (α-methyl-dl-tyrosine) resulted in a 72.5 ± 4.8 nM decrease in DA concentrations over a 2 h period. This study showed that CBM-FSCV may serve as a unique voltammetric technique to monitor relatively slow changes in tonic extracellular DA concentrations in vivo over a prolonged time period.
Joucla, Sébastien; Franconville, Romain; Pippow, Andreas; Kloppenburg, Peter; Pouzat, Christophe
2013-08-01
Calcium imaging has become a routine technique in neuroscience for subcellular to network level investigations. The fast progresses in the development of new indicators and imaging techniques call for dedicated reliable analysis methods. In particular, efficient and quantitative background fluorescence subtraction routines would be beneficial to most of the calcium imaging research field. A background-subtracted fluorescence transients estimation method that does not require any independent background measurement is therefore developed. This method is based on a fluorescence model fitted to single-trial data using a classical nonlinear regression approach. The model includes an appropriate probabilistic description of the acquisition system's noise leading to accurate confidence intervals on all quantities of interest (background fluorescence, normalized background-subtracted fluorescence time course) when background fluorescence is homogeneous. An automatic procedure detecting background inhomogeneities inside the region of interest is also developed and is shown to be efficient on simulated data. The implementation and performances of the proposed method on experimental recordings from the mouse hypothalamus are presented in details. This method, which applies to both single-cell and bulk-stained tissues recordings, should help improving the statistical comparison of fluorescence calcium signals between experiments and studies. Copyright © 2013 Elsevier Ltd. All rights reserved.
Performance of a low-power subsonic-arc-attachment arcjet thruster
NASA Technical Reports Server (NTRS)
Sankovic, John M.; Berns, Darren H.
1993-01-01
A subsonic-arc-attachment thruster design was scaled from a 30 kW 1960's vintage thruster to operate at nominally 3 kW. Performance measurements were obtained over a 1-4 kW power range using hydrogen as the propellant. Several modes of operation were identified and were characterized by varying degrees of voltage instability. A stability map was developed showing that the voltage oscillations were brought upon by elevated current or propellant levels. At a given specific energy level the specific impulse increased asymptotically with increased flow rates. Comparisons of performance were made between radial and tangential propellant injection. When the vortex flow was eliminated using radial injection, the operating voltages were lower at a given current, and the specific impulse and efficiency decreased. Tests were also conducted to determine the effects of background pressure on operation, and performance data were obtained at pressures of 0.047 Pa and 18 Pa. For a given specific energy level, the performance increased with a decrease in facility background pressure. Lowering the background pressure also caused a dramatic change in the voltage-current characteristic and the voltage stability, a phenomenon not previously reported with conventional supersonic-arc-attachment thrusters.
Ou-Yang, Chang-Feng; Chang, Chih-Chung; Chen, Shen-Po; Chew, Clock; Lee, Bo-Ru; Chang, Chih-Yuan; Montzka, Stephen A; Dutton, Geoffrey S; Butler, James H; Elkins, James W; Wang, Jia-Lin
2015-11-01
Ambient levels and variability of major atmospheric halocarbons, i.e. CFC-12, CFC-11, CFC-113, CCl4, CH3CCl3, C2HCl3, and C2Cl4 in a major metropolis (Taipei, Taiwan) were re-investigated after fourteen years by flask sampling in 2012. Our data indicates that the variability expressed as standard deviations (SD) of CFC-113 and CCl4 remained small (2.0 ppt and 1.9 ppt, respectively) for the 10th-90th percentile range in both sampling periods; whereas the variability of CFC-12, CFC-11, C2HCl3, and C2Cl4 measured in 2012 became noticeably smaller than observed in 1998, suggesting their emissions were reduced over time. By comparing with the background data of a global network (NOAA/ESRL/GMD baseline observatories), the ambient levels and distribution of these major halocarbons in Taipei approximated those at a background site (Mauna Loa) in 2012, suggesting that the fingerprint of the major halocarbons in a used-to-be prominent source area has gradually approached to that of the background atmosphere. Copyright © 2015 Elsevier Ltd. All rights reserved.
Prediction Metrics for Chemical Detection in Long-Wave Infrared Hyperspectral Imagery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chilton, Marie C.; Walsh, Stephen J.; Daly, Don S.
2009-01-29
A natural or anthropogenic process often generates a signature gas plume whose chemical constituents may be identified using hyperspectral imagery. A hyperspectral image is a pixel-indexed set of spectra where each spectrum reflects the chemical constituents of the plume, the atmosphere, the bounding background surface, and instrument noise. This study explored the relationship between gas absorbance and background emissivity across the long-wave infrared (LWIR) spectrum and how they affect relative gas detection sensitivity. The physics-based model for the observed radiance shows that high gas absorbance coupled with low background emissivity at a single wavenumber results in a stronger recorded radiance.more » Two sensitivity measures were developed to predict relative probability of detection using chemical absorbance and background emissivity: one focused on a single wavenumber while another accounted for the entire spectrum. The predictive abilities of these measures were compared to synthetic image analysis. This study simulated images with 499 distinct gases at each of 6 concentrations over 6 different background surfaces with the atmosphere and level of instrument noise held constant. The Whitened Matched Filter was used to define gas detection from an image spectrum. The estimate of a chemical’s probability of detection at a given concentration over a specific background was the proportion of detections in 500 trials. Of the 499 chemicals used in the images, 276 had estimated probabilities of detection below 0.2 across all backgrounds and concentrations; these chemicals were removed from the study. For 92.8 percent of the remaining chemicals, the single channel measure correctly predicted the background over which the chemical had the largest relative probability of detection. Further, the measure which accounted for information across all wavenumbers predicted the background over which the chemical had the largest relative probability of detection for 93.3 percent of the chemicals. These results suggest that the wavenumber with largest gas absorbance has the most influence over gas detection for this data. By furthering the in-silico experimentation with higher concentrations of gases not detectable in this experiment or by standardizing the gas absorbance spectra to unit vectors, these conclusions may be confirmed and generalized to more gases. This will help simplify image acquisition planning and the identification of unknowns in field collected images.« less
NASA Technical Reports Server (NTRS)
Fischer, M. L.; Alsop, D. C.; Cheng, E. S.; Clapp, A. C.; Cottingham, D. A.; Gundersen, J. O.; Koch, T. C.; Kreysa, E.; Meinhold, P. R.; Lange, A. E.
1992-01-01
The performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0.3 to 3 deg is presented. The system represents a collaborative effort combining a low-background 1-m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3, 6, 9, and 12/cm (90, 180, 270, and 360 GHz). The telescope has been flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of about 0.00001 with detectors operated at 0.3 K.
Zhang, Zhou; Wang, Xinming; Zhang, Yanli; Lü, Sujun; Huang, Zhonghui; Huang, Xinyu; Wang, Yuesi
2015-04-01
Benzene is a known human carcinogen causing leukemia, yet ambient air quality objectives for benzene are not available in China. The ambient benzene levels at four background sites in China's most developed coastal regions were measured from March 2012 to February 2013. The sites are: SYNECP, in the Northeast China Plain (NECP); YCNCP, in the North China Plain (NCP); THYRD, in the Yangtze River Delta (YRD) and DHPRD, in the Pearl River Delta (PRD). It was found that the mean annual benzene levels (578-1297 ppt) at the background sites were alarmingly higher, especially when compared to those of 60-480 pptv monitored in 28 cities in the United States. Wintertime benzene levels were significantly elevated at both sites (SYNECP and YCNCP) in northern China due to heating with coal/biofuels. Even at these background sites, the lifetime cancer risks of benzene (1.7-3.7E-05) all exceeded 1E-06 set by USEPA as acceptable for adults. At both sites in northern China, good correlations between benzene and CO or chloromethane, together with much lower toluene/benzene (T/B) ratios, suggested that benzene was largely related to coal combustion and biomass/biofuel burning. At the DHPRD site in the PRD, benzene revealed a highly significant correlation with methyl tert-butyl ether (MTBE), indicating that its source was predominantly from vehicle emissions. At the THYRD site in the YRD, higher T/B ratios and correlations between benzene and tetrachloroethylene, or MTBE, implied that benzene levels were probably affected by both traffic-related and industrial emissions. Copyright © 2015 Elsevier B.V. All rights reserved.
Precision measurement of the local bias of dark matter halos
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lazeyras, Titouan; Wagner, Christian; Schmidt, Fabian
2016-02-01
We present accurate measurements of the linear, quadratic, and cubic local bias of dark matter halos, using curved 'separate universe' N-body simulations which effectively incorporate an infinite-wavelength overdensity. This can be seen as an exact implementation of the peak-background split argument. We compare the results with the linear and quadratic bias measured from the halo-matter power spectrum and bispectrum, and find good agreement. On the other hand, the standard peak-background split applied to the Sheth and Tormen (1999) and Tinker et al. (2008) halo mass functions matches the measured linear bias parameter only at the level of 10%. The predictionmore » from the excursion set-peaks approach performs much better, which can be attributed to the stochastic moving barrier employed in the excursion set-peaks prediction. We also provide convenient fitting formulas for the nonlinear bias parameters b{sub 2}(b{sub 1}) and b{sub 3}(b{sub 1}), which work well over a range of redshifts.« less
Measurement and subtraction of Schumann resonances at gravitational-wave interferometers
NASA Astrophysics Data System (ADS)
Coughlin, Michael W.; Cirone, Alessio; Meyers, Patrick; Atsuta, Sho; Boschi, Valerio; Chincarini, Andrea; Christensen, Nelson L.; De Rosa, Rosario; Effler, Anamaria; Fiori, Irene; Gołkowski, Mark; Guidry, Melissa; Harms, Jan; Hayama, Kazuhiro; Kataoka, Yuu; Kubisz, Jerzy; Kulak, Andrzej; Laxen, Michael; Matas, Andrew; Mlynarczyk, Janusz; Ogawa, Tsutomu; Paoletti, Federico; Salvador, Jacobo; Schofield, Robert; Somiya, Kentaro; Thrane, Eric
2018-05-01
Correlated magnetic noise from Schumann resonances threatens to contaminate the observation of a stochastic gravitational-wave background in interferometric detectors. In previous work, we reported on the first effort to eliminate global correlated noise from the Schumann resonances using Wiener filtering, demonstrating as much as a factor of two reduction in the coherence between magnetometers on different continents. In this work, we present results from dedicated magnetometer measurements at the Virgo and KAGRA sites, which are the first results for subtraction using data from gravitational-wave detector sites. We compare these measurements to a growing network of permanent magnetometer stations, including at the LIGO sites. We show the effect of mutual magnetometer attraction, arguing that magnetometers should be placed at least one meter from one another. In addition, for the first time, we show how dedicated measurements by magnetometers near to the interferometers can reduce coherence to a level consistent with uncorrelated noise, making a potential detection of a stochastic gravitational-wave background possible.
Harmsen, Hans; Bernsen, Roos; Meeuwesen, Ludwien; Thomas, Siep; Dorrenboom, Govert; Pinto, David; Bruijnzeels, Marc
2005-01-01
Background Due to worldwide migration to Western countries, physicians are increasingly encountering patients with different ethnic backgrounds. Communication problems can arise as a result of differences in cultural backgrounds and poor language proficiency. Aims To assess the effectiveness of an educational intervention on intercultural communication aimed to decrease inequalities in care provided between Western and non-Western patients. Design of study A randomised controlled trial with randomisation at the GP level and outcome measurements at the patient level. Setting General practice in Rotterdam. Method Thirty-eight Dutch GPs in the Rotterdam region, with at least 25% of inhabitants of non-Western origin, and 2407 visiting patients were invited to participate in the study. A total of 986 consultations were finally included. The GPs were educated about cultural differences and trained in intercultural communication. Patients received a videotaped instruction focusing on how to communicate with their GP in a direct way. The primary outcome measure was mutual understanding and the secondary outcomes were patient's satisfaction and perceived quality of care. The intervention effect was assessed for all patients together, for the ‘Western’ and ‘non-Western’ patients, and for patients with different cultural backgrounds separately. Results An intervention effect was seen 6 months after the intervention, as improvement in mutual understanding (and some improvement in perceived quality of care) in consultations with ‘non-Western’ patients. Conclusions A double intervention on intercultural communication given to both physician and patient decreases the gap in quality of care between ‘Western’ and ‘non-Western’ patients. PMID:15904552
Test anxiety in mathematics among early undergraduate students in a British university in Malaysia
NASA Astrophysics Data System (ADS)
Karjanto, Natanael; Yong, Su Ting
2013-03-01
The level of test anxiety in mathematics subjects among early undergraduate students at the University of Nottingham Malaysia Campus is studied in this article. The sample consists of 206 students taking several mathematics modules who completed the questionnaires on test anxiety just before they entered the venue for midterm examinations. The sample data include the differences in the context of academic levels, gender groups and nationality backgrounds. The level of test anxiety in mathematics is measured using seven Likert questionnaire statements adapted from the Test Anxiety Inventory describing one's emotional feeling before the start of an examination. In general, the result shows that the students who had a lower score expectation were more anxious than those who had a higher score expectation, but that they obtained a better score than the expected score. In the context of academic levels, gender groups and nationality backgrounds, there were no significant correlations between the level of test anxiety and the students' academic performance. The effect size of the correlation values ranged from extremely small to moderate.
Time course of EEG background activity level before spontaneous awakening in infants.
Zampi, Chiara; Fagioli, Igino; Salzarulo, Piero
2002-12-01
This research aimed to investigate the time course of the cortical activity level preceding spontaneous awakening as a function of age and state. Two groups of infants (1-4 and 9-14 weeks of age) were continuously monitored by polygraphic recording and behavioural observation during the night. The electroencephalographic (EEG) activity recorded by the C3-O1 lead was analysed through an automatic analysis method which provides, for each 30-s epoch, a single measure, time domain based, of the EEG synchronization. The EEG parameter values were computed in the 6 min preceding each awakening out of non-rapid eye movement (NREM) sleep and out of rapid eye movement (REM) sleep. The EEG background activity level did not change in the minutes preceding awakening out of REM sleep. Awakening out of NREM sleep was preceded by a change of EEG activity level in the direction of higher activation with different time course according to the age. Both REM and NREM sleep results suggest that a high level of EEG activity is a prerequisite for the occurrence of a spontaneous awakening.
On the spatial distribution and evolution of ultrafine particles in Barcelona
NASA Astrophysics Data System (ADS)
Dall'Osto, M.; Querol, X.; Alastuey, A.; O'Dowd, C.; Harrison, R. M.; Wenger, J.; Gómez-Moreno, F. J.
2013-01-01
Sources and evolution of ultrafine particles were investigated both horizontally and vertically in the large urban agglomerate of Barcelona, Spain. Within the SAPUSS project (Solving Aerosol Problems by Using Synergistic Strategies), a large number of instruments was deployed simultaneously at different monitoring sites (road, two urban background, regional background, urban tower 150 m a.s.l., urban background tower site 80 m a.s.l.) during a 4 week period in September-October 2010. Particle number concentrations (N>5 nm) are highly correlated with black carbon (BC) at all sites only under strong vehicular traffic influences. By contrast, under cleaner atmospheric conditions (low condensation sink, CS) such correlation diverges towards much higher N/BC ratios at all sites, indicating additional sources of particles including secondary production of freshly nucleated particles. Size-resolved aerosol distributions (N10-500) as well as particle number concentrations (N>5 nm) allow us to identify three types of nucleation and growth events: (1) a regional type event originating in the whole study region and impacting almost simultaneously the urban city of Barcelona and the surrounding urban background area; (2) a regional type event impacting only the regional background area but not the urban agglomerate; (3) an urban type event which originates only within the city centre but whose growth continues while transported away from the city to the regional background. Furthermore, during these clean air days, higher N are found at tower level than at ground level only in the city centre whereas such a difference is not so pronounced at the remote urban background tower. In other words, this study suggests that the column of air above the city ground level possesses the optimal combination between low CS and high vapour source, hence enhancing the concentrations of freshly nucleated particles. By contrast, within stagnant polluted atmospheric conditions, higher N and BC concentrations are always measured at ground level relative to tower level at all sites. Our study suggests that the city centre of Barcelona is a source of non-volatile traffic primary particles (29-39% of N>5 nm), but other sources, including secondary freshly nucleated particles contribute up to 61-71% of particle number (N>5 nm) at all sites. We suggest that organic compounds evaporating from freshly emitted traffic particles are a possible candidate for new particle formation within the city and urban plume.
On the spatial distribution and evolution of ultrafine aerosols in urban air
NASA Astrophysics Data System (ADS)
Dall'Osto, M.; Querol, X.; Alastuey, A.; O'Dowd, C.; Harrison, R. M.; Wenger, J.; Gómez-Moreno, F. J.
2012-07-01
Sources and evolution of ultrafine particles (<0.1 μ m diameter) were investigated both horizontally and vertically in the large urban agglomerate of Barcelona, Spain. Within the SAPUSS project (Solving Aerosol Problems by Using Synergistic Strategies), a large number of instruments was deployed simultaneously at different monitoring sites (road, two urban background, regional background, urban tower 150 μa.s.l., urban background tower site 80 m a.s.l.) during a 4 week period in September-October 2010. Particle number concentrations (N>5nm) are highly correlated with black carbon (BC) at all sites only under strong vehicular traffic influences. By contrast, under clean atmospheric conditions (low condensation sinks, CS) such correlation diverges towards much higher N/BC ratios at all sites, indicating additional sources of particles including secondary production of freshly nucleated particles. This is also evident in the urban background annual mean diurnal trend of N/BC, showing a midday peak in all seasons. Size-resolved aerosol distributions (N10-500) as well as particle number concentrations (N>5nm) allow us to identify two types of nucleation and growth events: a regional type event originating in the whole study region and impacting almost simultaneously the urban city of Barcelona and the surrounding background area; and an urban type which originates only within the city centre but whose growth continues while transported away from the city to the regional background. Furthermore, during these clean air days, higher N are found at tower level than at ground level only in the city centre whereas such a difference is not so pronounced at the remote urban background tower. In other words, this study suggests that the column of air above the city ground level possesses the best compromise between low CS and high vapour source, hence enhancing the concentrations of freshly nucleated particles. By contrast, within stagnant polluted atmospheric conditions, higher N and BC concentrations are always measured at ground level relative to tower level at all sites. Our study suggests that the city centre is a source of both non-volatile traffic primary (29-39%) and secondary freshly nucleated particles (up to 61-71%) at all sites. We suggest that organic compounds evaporating from freshly emitted traffic particles are a possible candidate for new particle formation within the city and urban plume.
Martinez-Haro, Monica; Green, Andy J; Mateo, Rafael
2011-05-01
Medina lagoon in Andalusia has one of the highest densities of spent lead (Pb) shot in Europe. Blood samples from waterbirds were collected in 2006-2008 to measure Pb concentration (PbB), δ-aminolevulinic acid dehydratase (ALAD), oxidative stress biomarkers and plasma biochemistry. PbB above background levels (>20 μg/dl) was observed in 19% (n=59) of mallards (Anas platyrhynchos) and in all common pochards (Aythya ferina) (n=4), but common coots (Fulica atra) (n=37) and moorhens (Gallinula chloropus) (n=12) were all <20 μg/dl. ALAD ratio in mallards and coots decreased with PbB levels >6 μg/dl. In mallards, an inhibition of glutathione peroxidase (GPx) and an increased level of oxidized glutathione (oxGSH) in red blood cells (RBC) were associated with PbB levels >20 μg/dl. In coots, PbB levels were negatively related to vitamin A and carotenoid levels in plasma, and total glutathione in RBCs; and positively related with higher superoxide dismutase and GPx activities and % oxGSH in RBCs. Overall, the results indicate that previously assumed background levels of PbB for birds need to be revised. Copyright © 2011 Elsevier Inc. All rights reserved.
A Bayesian Method for Identifying Contaminated Detectors in Low-Level Alpha Spectrometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maclellan, Jay A.; Strom, Daniel J.; Joyce, Kevin E.
2011-11-02
Analyses used for radiobioassay and other radiochemical tests are normally designed to meet specified quality objectives, such relative bias, precision, and minimum detectable activity (MDA). In the case of radiobioassay analyses for alpha emitting radionuclides, a major determiner of the process MDA is the instrument background. Alpha spectrometry detectors are often restricted to only a few counts over multi-day periods in order to meet required MDAs for nuclides such as plutonium-239 and americium-241. A detector background criterion is often set empirically based on experience, or frequentist or classical statistics are applied to the calculated background count necessary to meet amore » required MDA. An acceptance criterion for the detector background is set at the multiple of the estimated background standard deviation above the assumed mean that provides an acceptably small probability of observation if the mean and standard deviation estimate are correct. The major problem with this method is that the observed background counts used to estimate the mean, and thereby the standard deviation when a Poisson distribution is assumed, are often in the range of zero to three counts. At those expected count levels it is impossible to obtain a good estimate of the true mean from a single measurement. As an alternative, Bayesian statistical methods allow calculation of the expected detector background count distribution based on historical counts from new, uncontaminated detectors. This distribution can then be used to identify detectors showing an increased probability of contamination. The effect of varying the assumed range of background counts (i.e., the prior probability distribution) from new, uncontaminated detectors will be is discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saey, P. R.J.; Ringbom, Anders; Bowyer, Ted W.
The Comprehensive Nuclear-Test-Ban Treaty (CTBT) specifies that radioxenon measurements should be performed at 40 or more stations worldwide within the International Monitoring System (IMS). Measuring radioxenon is one of the principle techniques to detect underground nuclear explosions. Specifically, presence and ratios of different radioxenon isotopes allows determining whether a detection event under consideration originated from a nuclear explosion or a civilian source. However, radioxenon monitoring on a global scale is a novel technology and the global civil background must be characterized sufficiently. This paper lays out a study, based on several unique measurement campaigns, of the worldwide concentrations and sourcesmore » of verification relevant xenon isotopes. It complements the experience already gathered with radioxenon measurements within the CTBT IMS programme and focuses on locations in Belgium, Germany, Kuwait, Thailand and South Africa where very little information was available on ambient xenon levels or interesting sites offered opportunities to learn more about emissions from known sources. The findings corroborate the hypothesis that a few major radioxenon sources contribute in great part to the global radioxenon background. Additionally, the existence of independent sources of 131mXe (the daughter of 131I) has been demonstrated, which has some potential to bias the isotopic signature of signals from nuclear explosions.« less
Radon induced background processes in the KATRIN pre-spectrometer
NASA Astrophysics Data System (ADS)
Fränkle, F. M.; Bornschein, L.; Drexlin, G.; Glück, F.; Görhardt, S.; Käfer, W.; Mertens, S.; Wandkowsky, N.; Wolf, J.
2011-10-01
The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next generation, model independent, large scale tritium β-decay experiment to determine the effective electron anti-neutrino mass by investigating the kinematics of tritium β-decay with a sensitivity of 200 meV/c 2 using the MAC-E filter technique. In order to reach this sensitivity, a low background level of 10 -2 counts per second (cps) is required. This paper describes how the decay of radon in a MAC-E filter generates background events, based on measurements performed at the KATRIN pre-spectrometer test setup. Radon (Rn) atoms, which emanate from materials inside the vacuum region of the KATRIN spectrometers, are able to penetrate deep into the magnetic flux tube so that the α-decay of Rn contributes to the background. Of particular importance are electrons emitted in processes accompanying the Rn α-decay, such as shake-off, internal conversion of excited levels in the Rn daughter atoms and Auger electrons. While low-energy electrons (<100 eV) directly contribute to the background in the signal region, higher energy electrons can be stored magnetically inside the volume of the spectrometer. Depending on their initial energy, they are able to create thousands of secondary electrons via subsequent ionization processes with residual gas molecules and, since the detector is not able to distinguish these secondary electrons from the signal electrons, an increased background rate over an extended period of time is generated.
A Neighborhood Wealth Metric for Use in Health Studies
Moudon, Anne Vernez; Cook, Andrea J.; Ulmer, Jared; Hurvitz, Philip M.; Drewnowski, Adam
2011-01-01
Background Measures of neighborhood deprivation used in health research are typically based on conventional area-based SES. Purpose The aim of this study is to examine new data and measures of SES for use in health research. Specifically, assessed property values are introduced as a new individual-level metric of wealth and tested for their ability to substitute for conventional area-based SES as measures of neighborhood deprivation. Methods The analysis was conducted in 2010 using data from 1922 participants in the 2008– 2009 survey of the Seattle Obesity Study (SOS). It compared the relative strength of the association between the individual-level neighborhood wealth metric (assessed property values) and area-level SES measures (including education, income, and percentage above poverty as single variables, and as the composite Singh index) on the binary outcome fair/poor general health status. Analyses were adjusted for gender, categoric age, race, employment status, home ownership, and household income. Results The neighborhood wealth measure was more predictive of fair/poor health status than area-level SES measures, calculated either as single variables or as indices (lower DIC measures for all models). The odds of having a fair/poor health status decreased by 0.85 [0.77, 0.93] per $50,000 increase in neighborhood property values after adjusting for individual-level SES measures. Conclusions The proposed individual-level metric of neighborhood wealth, if replicated in other areas, could replace area-based SES measures, thus simplifying analyses of contextual effects on health. PMID:21665069
Petrik, Jan; Drobna, Beata; Pavuk, Marian; Jursa, Stanislav; Wimmerova, Sona; Chovancova, Jana
2006-10-01
We measured organochlorine concentrations of 15 polychlorinated biphenyl congeners and six organochlorine pesticides (PCB28, 52, 101, 123(+149), 118, 114, 153, 105, 138(+163), 167, 156(+171), 157, 180, 170, 189, alpha-, beta-, gamma-HCH, HCB, p,p'-DDT and p,p'-DDE) in 2047 subjects from contaminated and background areas of eastern Slovakia. Data were collected in 2001 and analyzed by high-resolution gas chromatography with electron capture detection in 2002-2003. Elevated levels persist in subjects from Michalovce district, site of former production facility, after almost 20-years since the end of the PCB manufacturing. Sum of 15 PCB congeners was 3105 ng/g of lipid in the Michalovce district versus 871 ng/g of lipid for subjects from the background districts of Svidnik and Stropkov. Relatively high concentration in children from the Michalovce district, sum PCB = 766 ng/g of lipid versus 372 ng/g of lipid in children from background area suggest ongoing exposure from environmental reservoirs and contaminated food. Consistent differences between genders in both contaminated and background areas are reported here. Levels in males are about 20% higher in both districts. Levels of organochlorine pesticides, particularly of DDT metabolite DDE and hexachlorobenzene are also elevated in the Michalovce district, reflecting intensive use of pesticides in agriculture in the past. About 30% decrease in serum organochlorine levels was observed in comparison with our earlier samples collected in 1998. These results suggest that contamination with PCBs still remains a source of relatively high environmental exposure for subjects in the Michalovce district.
Background model for the Majorana Demonstrator
Cuesta, C.; Abgrall, N.; Aguayo, E.; ...
2015-01-01
The Majorana Collaboration is constructing a system containing 40 kg of HPGe detectors to demonstrate the feasibility and potential of a future tonne-scale experiment capable of probing the neutrino mass scale in the inverted-hierarchy region. To realize this, a major goal of the Majorana Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 cnt/(ROI-t-y) in the 4 keV region of interest around the Q-value at 2039 keV. This goal is pursued through a combination of a significant reduction of radioactive impurities in construction materials with analytical methods for background rejection, for example usingmore » powerful pulse shape analysis techniques profiting from the p-type point contact HPGe detectors technology. The effectiveness of these methods is assessed using simulations of the different background components whose purity levels are constrained from radioassay measurements.« less
Analysis of Data from the Balloon Borne Gamma RAy Polarimeter Experiment (GRAPE)
NASA Astrophysics Data System (ADS)
Wasti, Sambid K.; Bloser, Peter F.; Legere, Jason S.; McConnell, Mark L.; Ryan, James M.
2016-04-01
The Gamma Ray Polarimeter Experiment (GRAPE), a balloon borne polarimeter for 50~300 keV gamma rays, successfully flew in 2011 and 2014. The main goal of these balloon flights was to measure the gamma ray polarization of the Crab Nebula. Analysis of data from the first two balloon flights of GRAPE has been challenging due to significant changes in the background level during each flight. We have developed a technique based on the Principle Component Analysis (PCA) to estimate the background for the Crab observation. We found that the background depended mostly on the atmospheric depth, pointing zenith angle and instrument temperatures. Incorporating Anti-coincidence shield data (which served as a surrogate for the background) was also found to improve the analysis. Here, we present the calibration data and describe the analysis done on the GRAPE 2014 flight data.
Mercury in soil gas and air--A potential tool in mineral exploration
McCarthy, Joseph Howard; Vaughn, W.W.; Learned, R.E.; Meuschke, J.L.
1969-01-01
The mercury content in soil gas and in the atmosphere was measured in several mining districts to test the possibility that the mercury content in the atmosphere is higher over ore deposits than over barren ground. At Cortez, Nev., the distribution of anorhalous amounts of mercury in the air collected at ground level (soil gas) correlates well with the distribution of gold-bearing rocks that are covered by as much as 100 feet of gravel. The mercury content in the atmosphere collected at an altitude of 200 feet by an aircraft was 20 times background over a mercury posit and 10 times background over two porphyry copper deposits. Measurement of mercury in soil gas and air may prove to be a valuable exploration tool.
Sealy-Jefferson, Shawnita; Messer, Lynne; Slaughter-Acey, Jaime; Misra, Dawn P.
2016-01-01
Background The inter-relationships between objective (census-based) and subjective (resident reported) measures of the residential environment is understudied in African American (AA) populations. Methods Using data from the Life Influences on Fetal Environments Study (2009–2011) (n=1,387) of AA women, we quantified the area-level variation in subjective reports of residential healthy food availability, walkability, safety and disorder that can be accounted for with an objective neighborhood disadvantage index (NDI). Two-level generalized linear models estimated associations between objective and subjective measures of the residential environment, accounting for individual-level covariates. Results In unconditional models, intraclass correlation coefficients for block-group variance in subjective reports ranged from 11% (healthy food availability) to 30% (safety). Models accounting for the NDI (versus both NDI and individual level covariates) accounted for more variance in healthy food availability (23% versus 8%) and social disorder (40% versus 38%). The NDI and individual level variables accounted for 39% and 51% of the area-level variation in walkability and safety. Associations between subjective and objective measures of the residential environment were significant and in the expected direction. Conclusions Future studies on neighborhood effects on health, especially among AAs, should include a wide range of residential environment measures, including subjective, objective and spatial contextual variables. PMID:28160971
Geo-Spatial Characterization of Soil Mercury and Arsenic at a High-Altitude Bolivian Gold Mine.
Johnson, Glen D; Pavilonis, Brian; Caravanos, Jack; Grassman, Jean
2018-02-01
Soil mercury concentrations at a typical small-scale mine site in the Bolivian Andes were elevated (28-737 mg/kg or ppm) in localized areas where mercury amalgams were either formed or vaporized to release gold, but was not detectable beyond approximately 10 m from its sources. Arsenic was measurable, exceeding known background levels throughout the mine site (77-137,022 ppm), and was also measurable through the local village of Ingenio (36-1803 ppm). Although arsenic levels were high at all surveyed locations, its spatial pattern followed mercury, being highest where mercury was high.
A pilot study of human response to general aviation aircraft noise
NASA Technical Reports Server (NTRS)
Stearns, J.; Brown, R.; Neiswander, P.
1983-01-01
A pilot study, conducted to evaluate procedures for measuring the noise impact and community response to general aviation aircraft around Torrance Municipal Airport, a typical large GA airport, employed Torrance Airport's computer-based aircraft noise monitoring system, which includes nine permanent monitor stations surrounding the airport. Some 18 residences near these monitor stations were equipped with digital noise level recorders to measure indoor noise levels. Residents were instructed to fill out annoyance diaries for periods of 5-6 days, logging the time of each annoying aircraft overflight noise event and judging its degree of annoyance on a seven-point scale. Among the noise metrics studied, the differential between outdoor maximum A-weighted noise level of the aircraft and the outdoor background level showed the best correlation with annoyance; this correlation was clearly seen at only high noise levels, And was only slightly better than that using outdoor aircraft noise level alone. The results indicate that, on a national basis, a telephone survey coupled with outdoor noise measurements would provide an efficient and practical means of assessing the noise impact of general aviation aircraft.
Yao, Bo; Zhou, Ling-Xi; Liu, Zhao; Zhang, Gen; Xia, Ling-Jun
2014-07-01
An in-situ GC-ECD monitoring system was established at the Shangdianzi GAW regional background station (SDZ) for a 2-year atmospheric methyl chloroform (CH3CCl3) measurement experiment. Robust extraction of baseline signal filter was applied to the CH3CCl3 time series to separate the background and pollution data. The yearly averaged background mixing ratios of atmospheric CH3CCl3 were (9.03 +/- 0.53) x 10(-12) mol x mol(-1) in 2009 and (7.73 +/- 0.47) x 10(-12) in 2010, and the percentages of the background data in the whole data were 61.1% in 2009 and 60.4% in 2010, respectively. The yearly background CH3CCl3 mixing ratios at SDZ were consistent with the northern hemisphere background levels observed at Mace Head and Trinidad Head stations, but lower than the results observed at sites in southern China and some Chinese cities from 2001 to 2005. During the study period, background mixing ratios trends exhibited a decreasing rate of 1.39 x 10 12(-12) a(-1). The wind direction with the maximum CH3CCl3 mixing ratio was from the southwest sector and that with the minimum ratio was from the northeast sector. The differences between the maximum and the minimum average mixing ratios in the 16 wind directions were 0.77 x 10(-12) (2009) and 0.52 x 10(-12) (2010). In the 16 different wind directions, the averaged mixing ratio of CH3CCl3 in 2010 was lower than that in 2009 by 1.03 x 10(-12) -1.68 x 10(-12).
Alkhalawi, Eman; Kasper-Sonnenberg, Monika; Wilhelm, Michael; Völkel, Wolfgang; Wittsiepe, Jürgen
2016-01-01
In the context of the Duisburg Birth Cohort, this retrospective cohort study provides results of internal exposure to perfluorooctanoic acid (PFOA), perfluorooctanesulfonic acid (PFOS), and perfluorohexanesulfonic acid (PFHxS) in 156 mother-child pairs, and investigates whether and to what extent in utero exposure of these chemicals at German background levels exerts an effect on newborn and infant weight and length, and weight in relation to length expressed by ponderal index, in order to examine whether any reduction in weight is disproportionate to length. The levels of PFOA, PFOS, and PFHxS were determined in 81 maternal and 83 umbilical cord stored frozen plasma samples and 105 umbilical cord blood samples. Calculated factors were used to convert umbilical cord values to maternal levels. Weights and lengths were retrieved at birth and at 1, 4, 6, and 12 mo from examination booklets and ponderal index (kg/m 3 ) was calculated. Subsequently, correlations were assessed using multiple linear regressions and generalized estimation equations with each of the measures as a continuous outcome variable and with PFOA, PFOS, and PFHxS concentration quartiles as categorized predictor variables, while adjusting for relevant covariates. PFOA, PFOS, and PFHxS were generally within German background exposure levels. There was a significant association between PFOA, PFOS, and PFHxS concentration quartiles and decrease in ponderal index at birth but not weight or height. A nonsignificant negative association between exposure to all three compounds and birth weight was noted. Follow-up showed no sustained effect of the PFAA on anthropometric measures during the first year.
Trend in Air Quality of Kathmandu Valley: A Satellite, Observation and Modelling Perspective
NASA Astrophysics Data System (ADS)
Mahapatra, P. S.; Praveen, P. S.; Adhikary, B.; Panday, A. K.; Putero, D.; Bonasoni, P.
2016-12-01
Kathmandu (floor area of 340 km2) in Nepal is considered to be a `hot spot' of urban air pollution in South Asia. Its structure as a flat basin surrounded by tall mountains provides a unique case study for analyzing pollution trapped by topography. Only a very small number of cities with similar features have been studied extensively including Mexico and Santiago-de-Chile. This study presents the trend in satellite derived Aerosol Optical Depth (AOD) from MODIS AQUA and TERRA (3x3km, Level 2) over Kathmandu from 2000 to 2015. Trend analysis of AOD shows 35% increase during the study period. Determination of the background pollution would reveal the contribution of only Kathmandu Valley for the observation period. For this, AOD at 1340m altitude outside Kathmandu, but nearby areas were considered as background. This analysis was further supported by investigating AOD at different heights around Kathmandu as well as determining AOD from CALIPSO vertical profiles. These analysis suggest that background AOD contributed 30% in winter and 60% in summer to Kathmandu Valley's observed AOD. Thereafter the background AOD was subtracted from total Kathmandu AOD to determine contribution of only Kathmandu Valley's AOD. Trend analysis of only Kathmandu Valley AOD (subtracting background AOD) suggested an increase of 50% during the study period. Further analysis of Kathmandu's visibility and AOD suggest profound role of background AOD on decreasing visibility. In-situ Black Carbon (BC) mass concentration measurements (BC being used as a proxy for surface observations) at two sites within Kathmandu valley have been analyzed. Kathmandu valley lacks long term trends of ambient air quality measurement data. Therefore, surface observations would be coupled with satellite measurements for understanding the urban air pollution scenario. Modelling studies to estimate the contribution of background pollution to Kathmandu's own pollution as well as the weekend effect on air quality will be further discussed in detail.
Cuckoos vs. top predators as prime bioindicators of biodiversity in disturbed environments.
Morelli, Federico; Mousseau, Timothy A; Møller, Anders Pape
2017-10-01
We studied the abundance of the common cuckoo Cuculus canorus L. little cuckoo Cuculus poliocephalus L. and Asian cuckoo Cuculus saturatus L. and avian top predators as indicators of bird species richness (surrogate of biodiversity) in disturbed environments caused by radioactive contamination in Chernobyl, Ukraine and Fukushima, Japan, comparing their efficiency as indicators of local biodiversity hotspots. Bird species richness and birds abundance were quantified in each sample site during the breeding seasons between 2006 and 2015 and the level of background radiation was measured at every site. The correlation between number of cuckoos, top predators, land use composition and level of background radiation with bird species richness as response variable were examined using Generalized Linear Mixed Models. The strength of correlation between species richness and abundance and the covariates obtained from the model outputs were used as measure of the efficiency of each predictor, as well as the AIC of each model. Background radiation was negatively correlated with bird species richness and bird abundance in both countries, while number of top predators and cuckoos were both positively correlated with bird species richness and abundance. However, model with number of cuckoos was more performant than model with number of avian top predators. These differences in performance supports the hypothesis that cuckoos are a largely superior bioindicator than top predators. Copyright © 2017 Elsevier Ltd. All rights reserved.
Small Hot Jet Acoustic Rig Validation
NASA Technical Reports Server (NTRS)
Brown, Cliff; Bridges, James
2006-01-01
The Small Hot Jet Acoustic Rig (SHJAR), located in the Aeroacoustic Propulsion Laboratory (AAPL) at the NASA Glenn Research Center in Cleveland, Ohio, was commissioned in 2001 to test jet noise reduction concepts at low technology readiness levels (TRL 1-3) and develop advanced measurement techniques. The first series of tests on the SHJAR were designed to prove its capabilities and establish the quality of the jet noise data produced. Towards this goal, a methodology was employed dividing all noise sources into three categories: background noise, jet noise, and rig noise. Background noise was directly measured. Jet noise and rig noise were separated by using the distance and velocity scaling properties of jet noise. Effectively, any noise source that did not follow these rules of jet noise was labeled as rig noise. This method led to the identification of a high frequency noise source related to the Reynolds number. Experiments using boundary layer treatment and hot wire probes documented this noise source and its removal, allowing clean testing of low Reynolds number jets. Other tests performed characterized the amplitude and frequency of the valve noise, confirmed the location of the acoustic far field, and documented the background noise levels under several conditions. Finally, a full set of baseline data was acquired. This paper contains the methodology and test results used to verify the quality of the SHJAR rig.
Low gamma counting for measuring NORM/TENORM with a radon reducing system
NASA Astrophysics Data System (ADS)
Paschoa, Anselmo S.
2001-06-01
A detection system for counting low levels of gamma radiation was built by upgrading an existing rectangular chamber made of 18 metric tonne of steel fabricated before World War II. The internal walls, the ceiling, and the floor of the chamber are covered with copper sheets. The new detection system consists of a stainless steel hollow cylinder with variable circular apertures in the cylindrical wall and in the base, to allow introduction of a NaI (Tl) crystal, or alternatively, a HPGe detector in its interior. This counting system is mounted inside the larger chamber, which in turn is located in a subsurface air-conditioned room. The access to the subsurface room is made from a larger entrance room through a tunnel plus a glass anteroom to decrease the air-exchange rate. Both sample and detector are housed inside the stainless steel cylinder. This cylinder is filled with hyper pure nitrogen gas, before counting a sample, to prevent radon coming into contact with the detector surface. As a consequence, the contribution of the 214Bi photopeaks to the background gamma spectra is minimized. The reduction of the gamma radiation background near the detector facilitates measurement of naturally occurring radioactive materials (NORM), and/or technologically enhanced NORM (TENORM), which are usually at concentration levels only slightly higher than those typically found in the natural radioactive background.
Küssner, Mats B; de Groot, Annette M B; Hofman, Winni F; Hillen, Marij A
2016-01-01
As tantalizing as the idea that background music beneficially affects foreign vocabulary learning may seem, there is-partly due to a lack of theory-driven research-no consistent evidence to support this notion. We investigated inter-individual differences in the effects of background music on foreign vocabulary learning. Based on Eysenck's theory of personality we predicted that individuals with a high level of cortical arousal should perform worse when learning with background music compared to silence, whereas individuals with a low level of cortical arousal should be unaffected by background music or benefit from it. Participants were tested in a paired-associate learning paradigm consisting of three immediate word recall tasks, as well as a delayed recall task one week later. Baseline cortical arousal assessed with spontaneous EEG measurement in silence prior to the learning rounds was used for the analyses. Results revealed no interaction between cortical arousal and the learning condition (background music vs. silence). Instead, we found an unexpected main effect of cortical arousal in the beta band on recall, indicating that individuals with high beta power learned more vocabulary than those with low beta power. To substantiate this finding we conducted an exact replication of the experiment. Whereas the main effect of cortical arousal was only present in a subsample of participants, a beneficial main effect of background music appeared. A combined analysis of both experiments suggests that beta power predicts the performance in the word recall task, but that there is no effect of background music on foreign vocabulary learning. In light of these findings, we discuss whether searching for effects of background music on foreign vocabulary learning, independent of factors such as inter-individual differences and task complexity, might be a red herring. Importantly, our findings emphasize the need for sufficiently powered research designs and exact replications of theory-driven experiments when investigating effects of background music and inter-individual variation on task performance.
de Groot, Annette M. B.; Hofman, Winni F.; Hillen, Marij A.
2016-01-01
As tantalizing as the idea that background music beneficially affects foreign vocabulary learning may seem, there is—partly due to a lack of theory-driven research—no consistent evidence to support this notion. We investigated inter-individual differences in the effects of background music on foreign vocabulary learning. Based on Eysenck’s theory of personality we predicted that individuals with a high level of cortical arousal should perform worse when learning with background music compared to silence, whereas individuals with a low level of cortical arousal should be unaffected by background music or benefit from it. Participants were tested in a paired-associate learning paradigm consisting of three immediate word recall tasks, as well as a delayed recall task one week later. Baseline cortical arousal assessed with spontaneous EEG measurement in silence prior to the learning rounds was used for the analyses. Results revealed no interaction between cortical arousal and the learning condition (background music vs. silence). Instead, we found an unexpected main effect of cortical arousal in the beta band on recall, indicating that individuals with high beta power learned more vocabulary than those with low beta power. To substantiate this finding we conducted an exact replication of the experiment. Whereas the main effect of cortical arousal was only present in a subsample of participants, a beneficial main effect of background music appeared. A combined analysis of both experiments suggests that beta power predicts the performance in the word recall task, but that there is no effect of background music on foreign vocabulary learning. In light of these findings, we discuss whether searching for effects of background music on foreign vocabulary learning, independent of factors such as inter-individual differences and task complexity, might be a red herring. Importantly, our findings emphasize the need for sufficiently powered research designs and exact replications of theory-driven experiments when investigating effects of background music and inter-individual variation on task performance. PMID:27537520
Effects of noise levels and call types on the source levels of killer whale calls.
Holt, Marla M; Noren, Dawn P; Emmons, Candice K
2011-11-01
Accurate parameter estimates relevant to the vocal behavior of marine mammals are needed to assess potential effects of anthropogenic sound exposure including how masking noise reduces the active space of sounds used for communication. Information about how these animals modify their vocal behavior in response to noise exposure is also needed for such assessment. Prior studies have reported variations in the source levels of killer whale sounds, and a more recent study reported that killer whales compensate for vessel masking noise by increasing their call amplitude. The objectives of the current study were to investigate the source levels of a variety of call types in southern resident killer whales while also considering background noise level as a likely factor related to call source level variability. The source levels of 763 discrete calls along with corresponding background noise were measured over three summer field seasons in the waters surrounding the San Juan Islands, WA. Both noise level and call type were significant factors on call source levels (1-40 kHz band, range of 135.0-175.7 dB(rms) re 1 [micro sign]Pa at 1 m). These factors should be considered in models that predict how anthropogenic masking noise reduces vocal communication space in marine mammals.
Thoron (220Rn) in the indoor environment and work places
NASA Astrophysics Data System (ADS)
Ramachandran, T. V.; Sahoo, B. K.
2009-08-01
Ever since studies on uranium miners established the presence of a positive risk coefficient for the occurrence of lung cancer in miners exposed to elevated levels of 222Rn and its progeny, there was a great upsurge of interest in the measurement of 222Rn in the environment. Subsequently, considerable data is being generated on the levels of 222Rn in the environment across the worlds and is being periodically reported by UNSCEAR reports. In contrast to this, data pertaining to 220Rn in indoors and workplace environment is scaree due to the genral perception that its levels are negligible due to its shorter half life, and subsequently its contribution to the total inhalation dose is ignored, in the presence of other significant sources of natural radiation. This may not be true. Globally many locations have higher levels of natural background radiation due to elevated levels of primordial radio nuclides in the soil and their decay products like radon (222Rn), and thoron (220Rn) in the environment. Of late, technologically enhanced naturally occurring radioactive material has also contributed to the burden of background radiation. It is estimated that inhalation of 222Rn, 220Rn and their short lived progenies contribute more than 54% of the total natural background radiation dose received by the general population. 220Rn problem exists in industries which use thorium nitrate. Including India, lamps using thoriated gas mantles are still being used for indoor and outdoor lighting and by hawkers in rural as well as urban areas. Considering the fact that large amount of thorium nitrate is being handled by these industries, contribution to the inhalation dose of workers from 220Rn gas emanated and build up of the progeny in ambient air may also be quite significant. In this paper current status of 220Rn levels in the indoor environment and workplaces as well as in other industries where large amount of 232Th is being handled is being summarized. Methods of measurement and reported levels are also summarized.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kent Simmons, J.A.; Knap, A.H.
1991-04-01
The computer model Industrial Source Complex Short Term (ISCST) was used to study the stack emissions from a refuse incinerator proposed for the inland of Bermuda. The model predicts that the highest ground level pollutant concentrations will occur near Prospect, 800 m to 1,000 m due south of the stack. The authors installed a portable laboratory and instruments at Prospect to begin making air quality baseline measurements. By comparing the model's estimates of the incinerator contribution to the background levels measured at the site they predicted that stack emissions would not cause an increase in TSP or SO{sub 2}. Themore » incinerator will be a significant source of HCI to Bermuda air with ambient levels approaching air quality guidelines.« less
Teacher Knowledge and Instructional Quality of Beginning Teachers: Growth and Linkages
ERIC Educational Resources Information Center
Desimone, Laura; Hochberg, Eric D.; McMaken, Jennifer
2016-01-01
Background/Context: We lack strong and consistent information about which measures of knowledge matter most for good teaching and student learning, and what are trajectories of improvement for novice teachers. Research Questions: We explore the level, variation, and change in teacher knowledge and instruction in the first two years of teaching,…
High background levels of benzene oxide (BO) adducts with hemoglobin and albumin (BO-Hb and BO-Alb) have been measured in unexposed humans and animals. To test the influence of radical-mediated pathways on production of these BO-protein adducts, we employed Fenton chemistry to...
Regional background levels of exposure to fish from petroleum and combustion by-products were determined for the state of Ohio (mid-Western) and the mid-Atlantic region. Exposures were measured using bile metabolites that fluoresce at 290/335 nm for naphthalene (NAPH)-type compou...
Measuring the Implementation of a School Wellness Policy
ERIC Educational Resources Information Center
Snelling, Anastasia; Belson, Sarah Irvine; Watts, Erin; Malloy, Elizabeth; Van Dyke, Hugo; George, Stephanie; Schlicker, Sandra; Katz, Nancy Brenowitz
2017-01-01
Background: With the rise in childhood obesity, school policies related to nutrition and physical activity have been written and implemented. In this paper, we present a model to evaluate the degree to which state legislation for school health policies are implemented at the school level. Methods: Using Washington, DC's Healthy Schools Act (HSA)…
Minority Youth, Physical Activity, and Fitness Levels: Targeted Interventions Needed
ERIC Educational Resources Information Center
Fahlman, Mariane; Hall, Heather L.; Gutuskey, Lila
2015-01-01
Background: There is a clear disparity in health in the United States such that African Americans and Hispanics are more likely to suffer from morbidity and mortality related to chronic disease than their Caucasian counterparts. Purpose: We will determine whether fourth- and fifth-grade students' measures of health-related fitness and physical…
Sedentary and Physical Activity Habits of Obese Adolescents
ERIC Educational Resources Information Center
Starkoff, Brooke E.; Petosa, Rick L.; Balk, Elizabeth K.; Eneli, Ihuoma U.; Bonny, Andrea E.; Hoffman, Robert P.; Devor, Steven T.
2014-01-01
Background: The independent association between sedentary behavior (SB) and physical activity (PA) is such that, regardless of accumulated PA, high amounts of SB are detrimental to health, even in adolescents. Purpose: Our aim was to profile activity patterns in free-living environments and to measure levels of SB and light (LT) and moderate (MOD)…
Art and Science Education Collaboration in a Secondary Teacher Preparation Programme
ERIC Educational Resources Information Center
Medina-Jerez, William; Dambekalns, Lydia; Middleton, Kyndra V.
2012-01-01
Background and purpose: The purpose of this study was to record and measure the level of involvement and appreciation that prospective teachers in art and science education programmes demonstrated during a four-session integrated activity. Art and science education prospective teachers from a Rocky Mountain region university in the US worked in…
Hopes and Goals Survey for Use in STEM Elementary Education
ERIC Educational Resources Information Center
Douglas, K. Anna; Strobel, Johannes
2015-01-01
This study reports the development and validation studies of the Hopes and Goals Survey, an assessment designed to measure the level of hope of elementary students from diverse backgrounds, and its relation to science, technology, engineering, and math (STEM) studies and career. Data collected from students attending urban elementary schools were…
Sentence Repetition: What Does the Task Measure?
ERIC Educational Resources Information Center
Polišenská, Kamila; Chiat, Shula; Roy, Penny
2015-01-01
Background: Sentence repetition is gaining increasing attention as a source of information about children's sentence-level abilities in clinical assessment, and as a clinical marker of specific language impairment. However, it is widely debated what the task is testing and therefore how informative it is. Aims: (1) To evaluate the effects of…
A compact free space quantum key distribution system capable of daylight operation
NASA Astrophysics Data System (ADS)
Benton, David M.; Gorman, Phillip M.; Tapster, Paul R.; Taylor, David M.
2010-06-01
A free space quantum key distribution system has been demonstrated. Consideration has been given to factors such as field of view and spectral width, to cut down the deleterious effect from background light levels. Suitable optical sources such as lasers and RCLEDs have been investigated as well as optimal wavelength choices, always with a view to building a compact and robust system. The implementation of background reduction measures resulted in a system capable of operating in daylight conditions. An autonomous system was left running and generating shared key material continuously for over 7 days.
Background of SAM atom-fraction profiles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ernst, Frank
Atom-fraction profiles acquired by SAM (scanning Auger microprobe) have important applications, e.g. in the context of alloy surface engineering by infusion of carbon or nitrogen through the alloy surface. However, such profiles often exhibit an artifact in form of a background with a level that anti-correlates with the local atom fraction. This article presents a theory explaining this phenomenon as a consequence of the way in which random noise in the spectrum propagates into the discretized differentiated spectrum that is used for quantification. The resulting model of “energy channel statistics” leads to a useful semi-quantitative background reduction procedure, which ismore » validated by applying it to simulated data. Subsequently, the procedure is applied to an example of experimental SAM data. The analysis leads to conclusions regarding optimum experimental acquisition conditions. The proposed method of background reduction is based on general principles and should be useful for a broad variety of applications. - Highlights: • Atom-fraction–depth profiles of carbon measured by scanning Auger microprobe • Strong background, varies with local carbon concentration. • Needs correction e.g. for quantitative comparison with simulations • Quantitative theory explains background. • Provides background removal strategy and practical advice for acquisition.« less
Henry, Paula; Foots, Ashley
2012-03-01
Listening to music is one of the most common forms of recreational noise exposure. Previous investigators have demonstrated that maximum output levels from headphones can exceed safe levels. Although preferred listening levels (PLL) in quiet environments may be at acceptable levels, the addition of background noise will add to the overall noise exposure of a listener. Use of listening devices that block out some of the background noise would potentially allow listeners to select lower PLLs for their music. Although one solution is in-the-ear earphones, an alternative solution is the use of earmuffs in conjunction with earbuds. There were two objectives to this experiment. The first was to determine if an alternative to in-the-ear earphones for noise attenuation (the addition of earmuffs to earbuds) would allow for lower PLLs through a portable media player (PMP) than earbuds. The second was to determine if a surrounding background noise would yield different PLLs than a directional noise source. This was an experimental study. Twenty-four adults with normal hearing. PLLs were measured for three earphone configurations in three listening conditions. The earphone configurations included earbuds, canal earphones, and earbuds in combination with hearing protection devices (HPDs). The listening conditions included quiet, noise from one loudspeaker, and noise from four surrounding loudspeakers. Participants listened in each noise and earphone combination for as long as they needed to determine their PLL for that condition. Once the participant determined their PLL, investigators made a 5 sec recording of the music through a probe tube microphone. The average PLLs in each noise and earphone combination were used as the dependent variable. Ear canal level PLLs were converted to free-field equivalents to compare to noise exposure standards and previously published data. The average PLL as measured in the ear canal was 74 dBA in the quiet conditions and 84 dBA in the noise conditions. Paired comparisons of the PLL in the presence of background noise for each pair of earphone configurations indicated significant differences for each comparison. An inverse relationship was observed between attenuation and PLL whereby the greater the attenuation, the lower the PLL. A comparison of the single noise source condition versus the surrounding noise condition did not result in a significant effect. The present work suggests that earphones that take advantage of noise attenuation can reduce the level at which listeners set music in the presence of background noise. An alternative to in-the-ear earphones for noise attenuation is the addition of earmuffs to earbuds. American Academy of Audiology.
Semiconductor laser self-mixing micro-vibration measuring technology based on Hilbert transform
NASA Astrophysics Data System (ADS)
Tao, Yufeng; Wang, Ming; Xia, Wei
2016-06-01
A signal-processing synthesizing Wavelet transform and Hilbert transform is employed to measurement of uniform or non-uniform vibrations in self-mixing interferometer on semiconductor laser diode with quantum well. Background noise and fringe inclination are solved by decomposing effect, fringe counting is adopted to automatic determine decomposing level, a couple of exact quadrature signals are produced by Hilbert transform to extract vibration. The tempting potential of real-time measuring micro vibration with high accuracy and wide dynamic response bandwidth using proposed method is proven by both simulation and experiment. Advantages and error sources are presented as well. Main features of proposed semiconductor laser self-mixing interferometer are constant current supply, high resolution, simplest optical path and much higher tolerance to feedback level than existing self-mixing interferometers, which is competitive for non-contact vibration measurement.
Bakshi, A K; Prajith, Rama; Chinnaesakki, S; Pal, Rupali; Sathian, Deepa; Dhar, Ajay; Selvam, T Palani; Sapra, B K; Datta, D
2017-02-01
A comprehensive measurement of radioactivity concentrations of the primordial radionuclides 238 U, 232 Th and 40 K and their decay products in the soil samples collected from the sites of Indian research stations, Bharati and Maitri, at Antarctica was carried out using gamma spectrometric method. The activity concentrations in the soil samples of Bharati site were observed to be few times higher than of Maitri site. The major contributor to radioactivity content in the soil at Bharati site is 232 Th radionuclide in higher concentration. The gamma radiation levels based on the measured radioactivity of soil samples were calculated using the equation given in UNSCEAR 2000. The calculated radiation levels were compared with the measured values and found to correlate reasonably well. The study could be useful for the scientists working at Antarctica especially those at Indian station to take decision to avoid areas with higher radioactivity before erecting any facility for long term experiment or use. Copyright © 2016 Elsevier Ltd. All rights reserved.
Li, Changyang; Wang, Xiuying; Eberl, Stefan; Fulham, Michael; Yin, Yong; Dagan Feng, David
2015-01-01
Automated and general medical image segmentation can be challenging because the foreground and the background may have complicated and overlapping density distributions in medical imaging. Conventional region-based level set algorithms often assume piecewise constant or piecewise smooth for segments, which are implausible for general medical image segmentation. Furthermore, low contrast and noise make identification of the boundaries between foreground and background difficult for edge-based level set algorithms. Thus, to address these problems, we suggest a supervised variational level set segmentation model to harness the statistical region energy functional with a weighted probability approximation. Our approach models the region density distributions by using the mixture-of-mixtures Gaussian model to better approximate real intensity distributions and distinguish statistical intensity differences between foreground and background. The region-based statistical model in our algorithm can intuitively provide better performance on noisy images. We constructed a weighted probability map on graphs to incorporate spatial indications from user input with a contextual constraint based on the minimization of contextual graphs energy functional. We measured the performance of our approach on ten noisy synthetic images and 58 medical datasets with heterogeneous intensities and ill-defined boundaries and compared our technique to the Chan-Vese region-based level set model, the geodesic active contour model with distance regularization, and the random walker model. Our method consistently achieved the highest Dice similarity coefficient when compared to the other methods.
NASA Astrophysics Data System (ADS)
Kuik, F.; Lauer, A.; von Schneidemesser, E.; Butler, T. M.
2016-12-01
Many European cities continue to struggle with exceedances of NO2 limit values at measurement sites near roads, of which a large contribution is attributed to emissions from traffic. In this study, we explore how urban air quality can be improved with different traffic measures using the example of the Berlin-Brandenburg region. In order to simulate urban background air quality we use the Weather Research and Forecasting model with chemistry (WRF-Chem) at a horizontal resolution of 1km. We use emission input data at a horizontal resolution of 1km obtained by downscaling TNO-MACC III emissions based on local proxy data including population and traffic densities. In addition we use a statistical approach combining the simulated urban background concentrations with information on traffic densities to estimate NO2 at street level. This helps assessing whether the emission scenarios studied here can lead to significant reductions in NO2 concentrations at street level. The emission scenarios in this study represent a range of scenarios in which car traffic is replaced with bicycle traffic. Part of this study was an initial discussion phase with stakeholders, including policy makers and NGOs. The discussions have shown that the different stakeholders are interested in a scientific assessment of the impact of replacing car traffic with bicycle traffic in the Berlin-Brandenburg urban area. Local policy makers responsible for city planning and implementing traffic measures can make best use of scientific modeling results if input data and scenarios are as realistic as possible. For these reasons, the scenarios cover very idealized optimistic ("all passenger cars are replaced by bicycles") and pessimistic ("all cyclists are replaced by cars") scenarios to explore the sensitivity of simulated urban background air quality to these changes, as well as additional scenarios based on city-specific data to analyze more realistic situations. Of particular interest is how these impact street level NO2 concentrations.
Mars Methane at Gale Crater Shows Strong Seasonal Cycle: Updated Results from TLS-SAM on Curiosity
NASA Astrophysics Data System (ADS)
Webster, C. R.; Mahaffy, P. R.; Atreya, S. K.; Flesch, G.; Malespin, C.; McKay, C.; Martinez, G.; Moores, J.; Smith, C. L.; Martin-Torres, F. J.; Gomez-Elvira, J.; Zorzano, M. P.; Wong, M. H.; Trainer, M. G.; Eigenbrode, J. L.; Glavin, D. P.; Steele, A.; Archer, D., Jr.; Sutter, B.; Coll, P. J.; Freissinet, C.; Meslin, P. Y.; Pavlov, A.; Keymeulen, D.; Christensen, L. E.; Gough, R. V.; Schwenzer, S. P.; Navarro-Gonzalez, R.; Pla-García, J.; Rafkin, S. C.; Vicente-Retortillo, Á.; Kahanpää, H.; Viudez-Moreiras, D.; Smith, M. D.; Harri, A. M.; Genzer, M.; Hassler, D.; Lemmon, M. T.; Crisp, J. A.; Zurek, R. W.; Vasavada, A. R.
2017-12-01
In situ measurements of atmospheric methane have been made over a 5-year period at Gale Crater on Mars using the Tunable Laser Spectrometer (TLS) instrument in the Sample Analysis at Mars (SAM) suite on the Curiosity rover. We report two important observations: (i) a background level of mean value of 0.41 ±0.11 (2sem) that is about 5 times lower than some model predictions based on generation from UV degradation of micro-meteorites or interplanetary dust delivered to the martian surface; (ii) "spikes" of elevated levels of 7 ppbv attributed to episodic releases from small local sources, probably to the north of Gale crater1. Reports of plumes, patches or episodic releases of methane in the Martian atmosphere have to date eluded explanation in part because of their lack of repeatability in time or location. Our in situ measurements of the background methane levels exhibit a strong, repeatable seasonal variability. The amplitude of the observed seasonal cycle is 3 times greater than both that expected from the annual sublimation and freezing of polar carbon dioxide and that expected from methane production from ultraviolet (UV) degradation of exogenously-delivered surface material. The observed large seasonal variation in the background, and sporadic observations of higher pulses of 7 ppbv appear consistent with localized small sources of methane release from Martian surface reservoirs that may be occurring throughout the planet. We will present our updated data set, correlations of Mars methane with various other measurements from SAM, REMS, RAD and ChemCam instruments on Curiosity, as well as empirical models of UV surface insolation, and provide preliminary interpretation of results. 1 "Mars Methane Detection and Variability at Gale Crater", C. R. Webster et al., Science, 347, 415-417 (2015) and references therein. The research described here was carried out in part at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (NASA).
Sahoo, S K; Kierepko, R; Sorimachi, A; Omori, Y; Ishikawa, T; Tokonami, S; Prasad, G; Gusain, G S; Ramola, R C
2016-10-01
A comprehensive study was carried out to determine the radioactivity concentration of soil samples from different sites of a high background radiation area in the eastern coast of India, Odisha state. The dose rate measured in situ varied from 0.25 to 1.2 µSv h -1 The gamma spectrometry measurements indicated Th series elements as the main contributors to the enhanced level of radiation and allowed the authors to find the mean level of the activity concentration (±SD) for 226 Ra, 228 Th and 40 K as 130±97, 1110±890 and 360±140 Bq kg -1 , respectively. Human exposure from radionuclides occurring outdoor was estimated based on the effective dose rate, which ranged from 0.14±0.02 to 2.15±0.26 mSv and was higher than the UNSCEAR annual worldwide average value 0.07 mSv. Additionally, X-ray fluorescence analysis provided information about the content of major elements in samples and indicated the significant amount of Ti (7.4±4.9 %) in soils. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
HZE particle radiation induces tissue-specific and p53-dependent mutagenesis in transgenic animals
NASA Technical Reports Server (NTRS)
Chang, P. Y.; Kanazawa, N.; Lutze-Mann, L.; Winegar, R.
2001-01-01
Transgenic animals, with the integrated target gene, provide a unique approach for measuring and characterizing mutations in any tissue of the animal. We are using the plasmid-based lacZ transgenic mice with different p53 genetic background to examine radiation-induced genetic damage resulting from exposure to heavy particle radiation. We measured lacZ mutation frequencies (MF) in the brain and spleen tissues at various times after exposing animals to an acute dose of 1 Gy of 1GeV/amu iron particles. MF in the spleen of p53+/+ animals increased up to 2.6-fold above spontaneous levels at 8 weeks post irradiation. In contrast, brain MF from the same animals increased 1.7-fold above controls in the same period. In the p53-/- animals, brain MF increased to 2.2-fold above spontaneous levels at 1 week after treatment, but returned to control levels thereafter. Radiation also induced alterations in the spectrum of mutants in both tissues, accompanied by changes in the frequency of mutants with deletions extending past the transgene into mouse genomic DNA. Our results indicate that the accumulation of transgene MF after radiation exposure is dependant on the tissue examined as well as the p53 genetic background of the animals.
Multistep fluorescence gated proportional counters
NASA Technical Reports Server (NTRS)
Ramsey, Brian D.; Weisskopf, Martin C.
1990-01-01
A proportional counter is introduced in which the levels of energy and spatial resolutions and background rejection permit the application of the device to X-ray astronomy. A multistep approach is employed in which photons cause a signal that triggers the system and measures the energy of the incident photon. The multistep approach permits good energy resolution from parallel geometry and from the imaging stage due to coupling of the imaging and amplification stages. The design also employs fluorescence gating to reduce background, a method that is compatible with the multistep technique. Use of the proportional counter is reported for NASA's supernova campaign, and the pair background is below 0.0001 counts/sq cm sec keV at the xenon k-edge. Potential improvements and applications are listed including the CASES, POF, and EXOSS mission programs.
NASA Astrophysics Data System (ADS)
Réfy, D. I.; Brix, M.; Gomes, R.; Tál, B.; Zoletnik, S.; Dunai, D.; Kocsis, G.; Kálvin, S.; Szabolics, T.; JET Contributors
2018-04-01
Diagnostic alkali atom (e.g., lithium) beams are routinely used to diagnose magnetically confined plasmas, namely, to measure the plasma electron density profile in the edge and the scrape off layer region. A light splitting optics system was installed into the observation system of the lithium beam emission spectroscopy diagnostic at the Joint European Torus (JET) tokamak, which allows simultaneous measurement of the beam light emission with a spectrometer and a fast avalanche photodiode (APD) camera. The spectrometer measurement allows density profile reconstruction with ˜10 ms time resolution, absolute position calculation from the Doppler shift, spectral background subtraction as well as relative intensity calibration of the channels for each discharge. The APD system is capable of measuring light intensities on the microsecond time scale. However ˜100 μs integration is needed to have an acceptable signal to noise ratio due to moderate light levels. Fast modulation of the beam up to 30 kHz is implemented which allows background subtraction on the 100 μs time scale. The measurement covers the 0.9 < ρpol < 1.1 range with 6-10 mm optical resolution at the measurement location which translates to 3-5 mm radial resolution at the midplane due to flux expansion. An automated routine has been developed which performs the background subtraction, the relative calibration, and the comprehensive error calculation, runs a Bayesian density reconstruction code, and loads results to the JET database. The paper demonstrates the capability of the APD system by analyzing fast phenomena like pellet injection and edge localized modes.
NOx Emissions from Oil and Gas Production in the North Sea
NASA Astrophysics Data System (ADS)
Lee, J. D.; Foulds, A.; Purvis, R.; Vaughan, A. R.; Carslaw, D.; Lewis, A. C.
2015-12-01
North Sea oil is a mixture of hydrocarbons, comprising liquid petroleum and natural gas, produced from petroleum reservoirs beneath the North Sea. As of January 2015, the North Sea is the world's most active offshore drilling region with 173 rigs drilling. During the summer of 2015, a series of survey flights took place on the UKs FAAM BAe 146 research aircraft with the primary aim to assess background methane (and other hydrocarbons) levels in the drilling areas of the North Sea. Also measured were Nitrogen Oxides (NO and NO2), which are emitted from almost all combustion processes and are a key air pollutant, both directly and as a precursor to ozone (O3). The oil and gas platforms in the North Sea are often manned and require significant power generation and support vessels for their continued operation, processes that potentially emit significant amounts of NOx into an otherwise relative clean environment. During these flights we were able to measure the NOx (and any subsequently produced O3) emitted from specific rigs, as well as the NOx levels in the wider North Sea oil and gas production region (see figure for example). NOx mixing ratios of <10 ppbv were frequently observed in plumes, with significant perturbation to the wider North Sea background levels. NOx emissions from the rigs are point sources within the UKs National Atmospheric Emission Inventory (NAEI) and the measurements taken in plumes from individual rigs are used to assess the accuracy of these estimates.
Yoon, S; Pak, M-J; Park, S; Yoo, J; Ha, W-H; Jang, H-K; Kim, J K
2014-12-01
(32)P measurements of urine samples and internal dose assessments were conducted for workers in life science laboratories. A procedure for sample pre-treatment was established and validation was performed to exclude interference and to detect (32)P levels accurately. The detection conditions for Cherenkov radiation were evaluated and the accuracy of Cherenkov radiation measurements validated. The analytical and measurement procedures were applied to urine samples collected from 11 workers from life sciences laboratories. The results of the measurements generally indicated very low background radiation levels, but daily urine samples from two workers were above the minimum detectable activity. The (32)P concentrations for two of the workers were 29.3 ± 10.4 Bq•d(-1) and 24.1 ± 11.8 Bq•d(-1), respectively, at intake levels of 4.12 kBq and 2.61 kBq. The effective doses for these two workers were 4.6 μSv and 2.9 μSv. Overall, the results indicate very low levels of radioactivity, except for cases related to specific working conditions.
Below background levels of blood lead impact cytokine levels in male and female mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iavicoli, I.; Carelli, G.; Stanek, E.J.
2006-01-15
A number of studies have documented that Pb exerts immunotoxic effects on T lymphocytes. In studies designed to explore this general response over a broad dose range, female Swiss mice were administered six different diets containing Pb acetate 1 day after mating. During lactation, the mothers received the same feed given during pregnancy, and the same diets were administered to the offspring for 9 months after weaning. At the end of exposure, blood Pb level in the offspring was determined, and possible changes in two type 1 cytokines (IL-2, INF-{gamma}) and one type 2 cytokine (IL-4) in the serum weremore » measured. At higher dietary Pb levels (40 and 400 ppm), a significant increase in IL-4 production was associated with a profound decrease in INF-{gamma} and IL-2 production. At the lowest Pb diet level (0.02 ppm), which resulted in a blood lead level of (0.8 {mu}g/dL), which is below background (2-3 {mu}g/dL) values in humans, increases in INF-{gamma} and IL-2 production along with a significant decrease in IL-4 production were observed. The findings provide evidence of a reversal of lead-induced cytokine skewing depending on the blood lead concentration. As blood lead concentration increases, there is a notable skewing toward Th2, while the pattern is reversed favoring Th1 development at lower blood lead values. The present findings are also notable since they indicate the potential for dietary Pb to have significant biological effects below normal background concentrations.« less
Cross Section Measurements of the 76Ge (n ,n' γ) Reaction
NASA Astrophysics Data System (ADS)
Crider, B. P.; Peters, E. E.; Prados-Estévez, F. M.; Ross, T. J.; McEllistrem, M. T.; Yates, S. W.; Vanhoy, J. R.
2013-10-01
Neutrinoless double-beta decay (0 νββ) is a topic of great current interest and, as such, is the focus of several experiments and international collaborations. Two of these experiments, Majorana and GERDA, are seeking evidence of 0 νββ in the decay of 76Ge, where the signal would appear as a sharp peak in the energy spectrum at the Q-value of the reaction plus a small amount of recoil energy, or 2039 keV. Due to the high sensitivity of such a measurement, knowledge of background lines is critical. A study of 76Ga β- decay into 76Ge revealed a 2040.70(25)-keV transition from the 3951.70(14)-keV level, which, if populated, could potentially be a background line of concern. In addition to β- decay from 76Ga, a potential population mechanism could be cosmic-ray-induced inelastic neutron scattering. Measurements of the neutron-induced cross section of the 3951.70-keV level have been performed utilizing the 76 Ge (n ,n' γ) reaction at the University of Kentucky at neutron energies ranging from 4.3 to 4.9 MeV. This material is based upon work is supported by the U.S. National Science Foundation under grant no. PHY-0956310.
Valente, Daniel L.; Plevinsky, Hallie M.; Franco, John M.; Heinrichs-Graham, Elizabeth C.; Lewis, Dawna E.
2012-01-01
The potential effects of acoustical environment on speech understanding are especially important as children enter school where students’ ability to hear and understand complex verbal information is critical to learning. However, this ability is compromised because of widely varied and unfavorable classroom acoustics. The extent to which unfavorable classroom acoustics affect children’s performance on longer learning tasks is largely unknown as most research has focused on testing children using words, syllables, or sentences as stimuli. In the current study, a simulated classroom environment was used to measure comprehension performance of two classroom learning activities: a discussion and lecture. Comprehension performance was measured for groups of elementary-aged students in one of four environments with varied reverberation times and background noise levels. The reverberation time was either 0.6 or 1.5 s, and the signal-to-noise level was either +10 or +7 dB. Performance is compared to adult subjects as well as to sentence-recognition in the same condition. Significant differences were seen in comprehension scores as a function of age and condition; both increasing background noise and reverberation degraded performance in comprehension tasks compared to minimal differences in measures of sentence-recognition. PMID:22280587
Cai, Xiao-Ming; Xu, Xiu-Xiu; Bian, Lei; Luo, Zong-Xiu; Chen, Zong-Mao
2015-12-01
Determination of volatile plant compounds in field ambient air is important to understand chemical communication between plants and insects and will aid the development of semiochemicals from plants for pest control. In this study, a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) method was developed to measure ultra-trace levels of volatile plant compounds in field ambient air. The desorption parameters of TD, including sorbent tube material, tube desorption temperature, desorption time, and cold trap temperature, were selected and optimized. In GC-MS analysis, the selected ion monitoring mode was used for enhanced sensitivity and selectivity. This method was sufficiently sensitive to detect part-per-trillion levels of volatile plant compounds in field ambient air. Laboratory and field evaluation revealed that the method presented high precision and accuracy. Field studies indicated that the background odor of tea plantations contained some common volatile plant compounds, such as (Z)-3-hexenol, methyl salicylate, and (E)-ocimene, at concentrations ranging from 1 to 3400 ng m(-3). In addition, the background odor in summer was more abundant in quality and quantity than in autumn. Relative to previous methods, the TD-GC-MS method is more sensitive, permitting accurate qualitative and quantitative measurements of volatile plant compounds in field ambient air.
Purr, F; Bassu, M; Lowe, R D; Thürmann, B; Dietzel, A; Burg, T P
2017-12-05
Measuring small changes in refractive index can provide both sensitive and contactless information on molecule concentration or process conditions for a wide range of applications. However, refractive index measurements are easily perturbed by non-specific background signals, such as temperature changes or non-specific binding. Here, we present an optofluidic device for measuring refractive index with direct background subtraction within a single measurement. The device is comprised of two interdigitated arrays of nanofluidic channels designed to form an optical grating. Optical path differences between the two sets of channels can be measured directly via an intensity ratio within the diffraction pattern that forms when the grating is illuminated by a collimated laser beam. Our results show that no calibration or biasing is required if the unit cell of the grating is designed with an appropriate built-in asymmetry. In proof-of-concept experiments we attained a noise level equivalent to ∼10 -5 refractive index units (30 Hz sampling rate, 4 min measurement interval). Furthermore, we show that the accumulation of biomolecules on the surface of the nanochannels can be measured in real-time. Because of its simplicity and robustness, we expect that this inherently differential measurement concept will find many applications in ultra-low volume analytical systems, biosensors, and portable devices.
NASA Astrophysics Data System (ADS)
Miley, H. S.
2004-04-01
The Majorana Experiment proposes to measure the effective mass of the electron neutrino to as low as 0.02 eV using well-tested technology. A half-life of about 4E27 y, corresponding to a mass range of [0.02 - 0.07] eV can be reached by operating 500 kg of germanium enriched to 86% in 76Ge deep underground. Radiological backgrounds of cosmogenic or primordial origin will be greatly reduced by ultra-low-background screening of detector, structural, and shielding materials, by chemical processing of materials, and by electronic rejection of multi-site events in the detector. Electronic background reduction is achieved with pulse-shape analysis, detector segmentation, and detector-to-detector coincidence rejection. Sensitivity calculations assuming worst-case germanium cosmogenic activation predict rapid growth in mass sensitivity (T1/2 at 90%CL) after the beginning of detector production: [0.08-0.28] eV at ~1 year, [0.04-0.14] eV at ~2.5 years, [0.03-0.10] eV at ~5 years, and [0.02 - 0.07] eV at ~10 years. The impact of primordial backgrounds in structural and electronic components is being studied at the 1 μBq/kg level, and appears to be controllable to below levels needed to attain these results.
NASA Astrophysics Data System (ADS)
DeCarlo, P. F.; Goetz, J. D.
2017-12-01
Emission inventories in the state of Pennsylvania are largely self-reported numbers by industry and significantly underestimate methane emissions at the facility level compared to measured emissions. Nevertheless, these emission inventories are used in making policy decisions at the state level with regard to reduction and mitigation of methane emissions from oil and gas development. A series of measurements made in northeastern Pennsylvania in 2012 and 2015 provide data for comparison to reported emission inventories at the facility level and changes in total emissions at the state and regional level. Tracer release studies performed in 2012 indicate up to an order of magnitude underestimate for facility level emissions. A novel methane background analysis on the 2012 and 2015 datasets indicates approximately a 300% increase in methane emissions over that three-year period scaling with increasing natural gas in the northeast region of Pennsylvania. State emission inventories indicate an 11% decrease over the same time period clearly at odds with the measurements. This presentation will also discuss potential areas of discrepancy with the emission inventories.
Arruti, A; Fernández-Olmo, I; Irabien, A
2011-05-01
Air pollution by particulate matter is well linked with anthropogenic activities; the global economic crisis that broke out in the last year may be a proper indicator of this close relationship. Some economic indicators show the regional effects of the crisis on the Cantabria Region. The present work aims to evaluate the impact of the economic crisis on PM10 levels and composition at the major city of the region, Santander. Some metals linked to anthropogenic activities were measured at Santander and studied by Positive Matrix Factorization; this statistical analysis allowed to identify three main factors: urban background, industrial and molybdenum-related factor. The main results show that the temporal trend of the levels of the industrial tracers found in the present study are well agree with the evolution of the studied economic indicators; nevertheless, the urban background tracers and PM10 concentration levels are not well correlated with the studied economic indicators. Copyright © 2011 Elsevier Ltd. All rights reserved.
Technical Note: The Initial Stages of Statistical Data Analysis
Tandy, Richard D.
1998-01-01
Objective: To provide an overview of several important data-related considerations in the design stage of a research project and to review the levels of measurement and their relationship to the statistical technique chosen for the data analysis. Background: When planning a study, the researcher must clearly define the research problem and narrow it down to specific, testable questions. The next steps are to identify the variables in the study, decide how to group and treat subjects, and determine how to measure, and the underlying level of measurement of, the dependent variables. Then the appropriate statistical technique can be selected for data analysis. Description: The four levels of measurement in increasing complexity are nominal, ordinal, interval, and ratio. Nominal data are categorical or “count” data, and the numbers are treated as labels. Ordinal data can be ranked in a meaningful order by magnitude. Interval data possess the characteristics of ordinal data and also have equal distances between levels. Ratio data have a natural zero point. Nominal and ordinal data are analyzed with nonparametric statistical techniques and interval and ratio data with parametric statistical techniques. Advantages: Understanding the four levels of measurement and when it is appropriate to use each is important in determining which statistical technique to use when analyzing data. PMID:16558489
Marryat, Louise; Thompson, Lucy; Minnis, Helen; Wilson, Philip
2018-01-01
Background This paper examines socioeconomic inequalities in mental health at school entry and explores changes in these inequalities over the first 3 years of school. Methods The study utilises routinely collected mental health data from education records and demographic data at ages 4 and 7 years, along with administrative school-level data. The study was set in preschool establishments and schools in Glasgow City, Scotland. Data were available on 4011 children (59.4%)at age 4 years, and 3166 of these children were followed at age 7 years (46.9% of the population). The main outcome measure was the teacher-rated Goodman’s Strengths and Difficulties Questionnaire (4–16 version) at age 7 years, which measures social, emotional and behavioural difficulties. Results Children living in the most deprived area had higher levels of mental health difficulties at age 4 years, compared with their most affluent counterparts (7.3%vs4.1% with abnormal range scores). There was a more than threefold widening of this disparity over time, so that by the age of 7 years, children from the most deprived area quintile had rates of difficulties 3.5 times higher than their more affluent peers. Children’s demographic backgrounds strongly predicted their age 7 scores, although schools appeared to make a significant contribution to mental health trajectories. Conclusions Additional support to help children from disadvantaged backgrounds at preschool and in early primary school may help narrow inequalities. Children from disadvantaged backgrounds started school with a higher prevalence of mental health difficulties, compared with their more advantaged peers, and this disparity widened markedly over the first 3 years of school. PMID:29056594
Allergens and β-Glucans in Dutch Homes and Schools: Characterizing Airborne Levels
Krop, Esmeralda J. M.; Jacobs, José H.; Sander, Ingrid; Raulf-Heimsoth, Monika; Heederik, Dick J. J.
2014-01-01
Background Indoor air quality has an effect on respiratory health. Children are more vulnerable to a decreased indoor air quality as their lungs are still developing. We measured levels of allergens and β-(1,3)-glucans in 19 school buildings and determined whether measured levels could be reproduced. School levels were compared to those in 169 homes and the effect of building characteristics on both home and school exposure was explored. Methods Electrostatic Dust fall Collectors were placed in school buildings for 8 weeks and in homes for 2 weeks to collect settled airborne dust. Cat, dog, and mouse allergen levels, domestic mite antigen levels and β-(1,3)-glucans were measured in the extracts from the collectors. Results were corrected for sampling duration. Using questionnaire data, relations between measured levels and building and classroom characteristics were explored. Results In schools, exposure levels were highest in classrooms and were influenced by the socioeconomic status of the children, the season measurements were performed, moisture status of the building and pet ownership. Repeated measurements in different seasons and over the years showed significantly different levels. Home exposure was influenced by socioeconomic status, occupancy and pet ownership. Domestic mite antigen was found in higher levels in extracts from homes compared to schools while pet allergen levels were 13 times higher in schools compared to homes without pets. For mouse allergen overall levels of exposure were low but still two times higher in schools compared to homes. Levels of β-(1,3)-glucans were also approximately two times higher in schools than in homes. Conclusion Exposure levels of several allergens and β-(1,3)-glucans in schools differ over time and are higher than in homes. For children, exposure levels measured at school could contribute to their total exposure as especially animal allergen levels can be much higher in schools compared to homes. PMID:24551183
Crider, B. P.; Peters, E. E.; Allmond, J. M.; ...
2015-09-11
The experimental signature in searches for the neutrinoless double- decay of 76Ge is a peak near 2039 keV in the spectrum. Given the low probability of the process, it is important that the background in this region be well understood. Moreover, inelastic scattering reactions with neutrons from muon-induced interactions and ( ,n) reactions in the surrounding materials or in the detector can provide contributions to the background. We also measured the production cross sections for rays from the 76Ge(n,n ) reaction in the 2039-keV region at incident neutron energies up to 4.9 MeV. In addition to determining that the crossmore » sections of a previously known 2040.7-keV ray from the 3952-keV level in 76 Ge are rather small, we find that a larger contribution arises from a 2037.5-keV ray which is attributed to a newly identified level at 3147 keV in 76Ge. Finally, a third contribution is also possible from another new level at 3577 keV. These results indicate that the 2039-keV region in 76Ge neutrinoless double- decay searches is more complex than was previously thought.« less
Chen, Siyuan; Epps, Julien; Chen, Fang
2013-01-01
Using the task-evoked pupillary response (TEPR) to index cognitive load can contribute significantly to the assessment of memory function and cognitive skills in patients. However, the measurement of pupillary response is currently limited to a well-controlled lab environment due to light reflex and also relies heavily on expensive video-based eye trackers. Furthermore, commercial eye trackers are usually dedicated to gaze direction measurement, and their calibration procedure and computing resource are largely redundant for pupil-based cognitive load measurement (PCLM). In this study, we investigate the validity of cognitive load measurement with (i) pupil light reflex in a less controlled luminance background; (ii) a low-cost infrared (IR) webcam for the TEPR in a controlled luminance background. ANOVA results show that with an appropriate baseline selection and subtraction, the light reflex is significantly reduced, suggesting the possibility of less constrained practical applications of PCLM. Compared with the TEPR from a commercial remote eye tracker, a low-cost IR webcam achieved a similar TEPR pattern and no significant difference was found between the two devices in terms of cognitive load measurement across five induced load levels.
Low-frequency noise measurements: applications, methodologies and instrumentation
NASA Astrophysics Data System (ADS)
Ciofi, Carmine; Neri, Bruno
2003-05-01
Low frequency noise measurements (f<10Hz) are a powerful tool for the investigation of the quality and reliability of electron devices and material. In most cases, however, the application of this technique is made quite difficult both because of the effect of external interferences (temperature fluctuations, EMI, mechanical vibrations, etc.) and because of the high level of flicker noise of the commercial instrumentation. In this paper the most remarkable results we obtained by using low frequency noise measurements for the characterization of the reliability of VLSI metallic interconnections and thin oxides are resumed. Moreover, we discuss the effects of the several sources of noise and interferences which contribute to reduce the sensitivity of the measurement chain. In particular, we demonstrate that by means of a proper design, dedicated instrumentation can be built which allows for a considerable reduction of the overall background noise. Examples will be given with reference to voltage and transresistance amplifiers (both AC and DC coupled), to programmable biasing systems (both current and voltage sources), to thermal stabilization systems and to data acquisition systems. Finally, we will discuss methods which may allow, in proper conditions, to accurately measure noise levels well below the background noise of the input preamplifiers coupled to the device under test. As the systems we discuss are characterized by moderate complexity and employ components readily available on the market, we trust that this paper may also serve as a simple guideline to anyone interested in exploiting the possibility of using very low frequency noise measurements by building his own instrumentation.
Measurement of suspended solids in lakes and oceans using satellite remote sensing data
NASA Technical Reports Server (NTRS)
Sydor, M. (Principal Investigator)
1980-01-01
Using satellite remote sensing data to measure low concentrations of suspended solids in lakes and oceans requires careful evaluation of background signals from the atmosphere and the water surface. Typical background corrections for Lake Superior are presented and the spectral distribution of the residual radiance from three major categories of turbidity in the lake are determined. The results indicate that for large bodies of water, some general information on atmospheric scattering, water clarity, and the optical properties of suspended solids allows estimates of concentrations of suspended solids to within + or - 0.5 mg/L without using real time ground truth data. Under calibrated conditions the threshold detection level is 0.3 mg/L for the fine particulates dispersed throughout the lake and 1 mg/L for the highly light absorbing effluent from rivers. Comparisons of the minimum reflectance over the open lake areas with reflection from the highly absorbing tannin water from rivers provides a check on the clarity of the atmosphere and the excessive background scatter from the water surface.
Oxidative DNA damage background estimated by a system model of base excision repair
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokhansanj, B A; Wilson, III, D M
Human DNA can be damaged by natural metabolism through free radical production. It has been suggested that the equilibrium between innate damage and cellular DNA repair results in an oxidative DNA damage background that potentially contributes to disease and aging. Efforts to quantitatively characterize the human oxidative DNA damage background level based on measuring 8-oxoguanine lesions as a biomarker have led to estimates varying over 3-4 orders of magnitude, depending on the method of measurement. We applied a previously developed and validated quantitative pathway model of human DNA base excision repair, integrating experimentally determined endogenous damage rates and model parametersmore » from multiple sources. Our estimates of at most 100 8-oxoguanine lesions per cell are consistent with the low end of data from biochemical and cell biology experiments, a result robust to model limitations and parameter variation. Our results show the power of quantitative system modeling to interpret composite experimental data and make biologically and physiologically relevant predictions for complex human DNA repair pathway mechanisms and capacity.« less
Cooke, K M; Simmonds TPG; Nickless, G; Makepeace, A P
2001-09-01
A sensitive and selective technique for the quantitative measurement of atmospheric perfluorocarbon trace species at the sub part per quadrillion (10(-15)) levels is presented. The method utilizes advances in adsorbent enrichment techniques coupled with benchtop capillary gas chromatography and negative ion-chemical ionization mass spectrometry. The development and enhancement of sampling technology for tracer experiments is described, and the results from background measurements and a preliminary field experiment are presented. The overall precision of the analytical method with respect to the preferred tracer for these atmospheric transport studies, perfluoromethylcyclohexane, was +/-1.7%. The background concentrations of perfluorodimethylcyclobutane, perfluoromethylcyclopentane, and perfluoromethylcyclohexane at a remote coastal location (Mace Head, Ireland, 53 degrees N, 10 degrees W) were found to be 2.5 (+/-0.4), 6.8 (+/-1.0), and 5.2 fL L(-1) (+/-1.3), respectively. Background concentrations within an urban conurbation (Bristol, U.K.) were slightly greater at 3.0 (+/-1.5), 8.1 (+/-1.8), and 6.3 fL L(-1) (+/-1.1), respectively.
Support of selected X-ray studies to be performed using data from the Uhuru (SAS-A) satellite
NASA Technical Reports Server (NTRS)
Garmire, G. P.
1976-01-01
A new measurement of the diffuse X-ray emission sets more stringent upper limits on the fluctuations of the background and on the number counts of X-ray sources with absolute value of b 20 deg than previous measurements. A random sample of background data from the Uhuru satellite gives a relative fluctuation in excess of statistics of 2.0% between 2.4 and 6.9 keV. The hypothesis that the relative fluctuation exceeds 2.9% can be rejected at the 90% confidence level. No discernable energy dependence is evident in the fluctuations in the pulse height data, when separated into three energy channels of nearly equal width from 1.8 to 10.0 keV. The probability distribution of fluctuations was convolved with the photon noise and cosmic ray background deviation (obtained from the earth-viewing data) to yield the differential source count distribution for high latitude sources. Results imply that a maximum of 160 sources could be between 1.7 and 5.1 x 10 to the -11 power ergs/sq cm/sec (1-3 Uhuru counts).
NASA Astrophysics Data System (ADS)
Hernández-Paniagua, Iván Y.; Lowry, David; Clemitshaw, Kevin C.; Palmer, Paul I.; Fisher, Rebecca E.; France, James L.; Mendoza, Alberto; O'Doherty, Simon; Forster, Grant; Lanoisellé, M.; Nisbet, Euan G.
2018-03-01
Ambient carbon monoxide (CO) and meteorological parameters measured at the Egham (EGH) semi-rural site in SW London during 2000-2015 have permitted wind sector analysis of diurnal and seasonal cycles, and interpretation of long-term trends. CO daily amplitudes are used as a proxy for anthropogenic emissions. At EGH, morning and evening peaks in CO arise from the dominant contribution of road transport sources. Smaller amplitudes are observed during weekends than weekdays due to lower combustion emissions, and for mornings compared to evenings due to the timing of the development and break-up of the nocturnal inversion layer or planetary boundary layer (PBL). A wavelet transform revealed that the dominant mode of CO variability is the annual cycle, with apparent winter maxima likely due to increased CO emissions from domestic heating with summer minima ascribed to enhanced dispersion and dilution during the annual maximum of PBL mixing heights. Over the last two decades, both mitigation measures to reduce CO emissions and also a major switch to diesel cars, have accompanied a change at EGH from the dominance of local diurnal sources to a site measuring close to Atlantic background levels in summer months. CO observed in the S and SW wind sectors has declined by 4.7 and 5.9 ppb yr-1 respectively. The EGH CO record shows the highest levels in the early 2000s, with levels in E and calm winds comparable to those recorded at background stations in Greater London. However, since 2012, levels in S-SW sector have become more comparable with Mace Head background except during rush-hour periods. Marked declines in CO are observed during 2000-2008 for the NE, E, SE (London) and calm wind sectors, with the smallest declines observed for the S, SW and W (background) sectors. For the majority of wind sectors, the decline in CO is less noticeable since 2008, with an apparent stabilisation for NE, E and SE after 2009. The EGH CO data record exhibits a similar but slower exponential decay, but from a much lower starting concentration, than do CO data recorded at selected monitoring sites in urban areas in SE England. CO/CO2 residuals determined using hourly averaged datain the diurnal cycle demonstrate a clear decline in CO from 2000 to 2015 during daily periods of increased vehicle traffic, which is consistent with a sustained reduction in CO emissions from the road transport sector.
2014-01-01
Background A low level of education and the migration background of parents are associated with the development of caries in children. The aim of this study was to evaluate whether a higher educational level of parents can overcome risks for the development of caries in immigrants in Vienna, Austria. Methods The educational level of the parents, the school type, and the caries status of 736 randomly selected twelve-year-old children with and without migration background was determined in this cross sectional study. In children attending school in Vienna the decayed, missing, and filled teeth (DMFT) index was determined. For statistical analysis, a mixed negative-binomial-model was used. Results The caries status of the children with migration background was significantly worse compared to that of the native Viennese population. A significant interaction was found between migration background and the educational level of the parents (p = 0.045). No interaction was found between the school type and either the migration background (p = 0.220) or the education level of the parents (p = 0.08). In parents with a higher scholarly education level, migration background (p < 0.01) and school type (p = 0.018) showed an association with DMFT values. In parents with a low education level, however, migration background and school type had no significant association with DMFT values. Conclusion These data indicate that children with a migration background are at higher risk to acquire caries than other Viennese children, even when the parents have received a higher education. PMID:24886105
Airborne intercomparison of nitric oxide measurement techniques
NASA Technical Reports Server (NTRS)
Hoell, James M., Jr.; Gregory, Gerald L.; Mcdougal, David S.; Torres, Arnold L.; Davis, Douglas D.
1987-01-01
Results from an airborne intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted during missions flown in the fall of 1983 and spring of 1984. Instruments intercompared included a laser-induced fluorescence (LIF) system and two chemiluminescence instruments (CL). NO mixing ratios from below 5 pptv (parts per trillion by volume) to greater than 100 pptv were reported, with the majority less than 20 pptv. Good correlation was observed between the measurements reported by the CL and LIF techniques. The general level of agreement observed for the ensemble of measurements obtained during the two missions provides the basis from which one can conclude that equally 'valid' measurements of background levels of NO can be expected from either CL or LIF instruments. At the same time the periods of disagreement that were observed between the CL and LIF instruments as well as between the two CL instruments highlight the difficulty of obtaining reliable measurements with NO mixing ratios in the 5-20 pptv range and emphasize the vigilance that should be maintained in future NO measurements.
Bonefeld, Meike; Dickhäuser, Oliver
2018-01-01
Biases in pre-service teachers' evaluations of students' performance may arise due to stereotypes (e.g., the assumption that students with a migrant background have lower potential). This study examines the effects of a migrant background, performance level, and implicit attitudes toward individuals with a migrant background on performance assessment (assigned grades and number of errors counted in a dictation). Pre-service teachers ( N = 203) graded the performance of a student who appeared to have a migrant background statistically significantly worse than that of a student without a migrant background. The differences were more pronounced when the performance level was low and when the pre-service teachers held relatively positive implicit attitudes toward individuals with a migrant background. Interestingly, only performance level had an effect on the number of counted errors. Our results support the assumption that pre-service teachers exhibit bias when grading students with a migrant background in a third-grade level dictation assignment.
Bonefeld, Meike; Dickhäuser, Oliver
2018-01-01
Biases in pre-service teachers’ evaluations of students’ performance may arise due to stereotypes (e.g., the assumption that students with a migrant background have lower potential). This study examines the effects of a migrant background, performance level, and implicit attitudes toward individuals with a migrant background on performance assessment (assigned grades and number of errors counted in a dictation). Pre-service teachers (N = 203) graded the performance of a student who appeared to have a migrant background statistically significantly worse than that of a student without a migrant background. The differences were more pronounced when the performance level was low and when the pre-service teachers held relatively positive implicit attitudes toward individuals with a migrant background. Interestingly, only performance level had an effect on the number of counted errors. Our results support the assumption that pre-service teachers exhibit bias when grading students with a migrant background in a third-grade level dictation assignment. PMID:29867618
ERIC Educational Resources Information Center
Trace, Jonathan; Brown, James Dean; Janssen, Gerriet; Kozhevnikova, Liudmila
2017-01-01
Cloze tests have been the subject of numerous studies regarding their function and use in both first language and second language contexts (e.g., Jonz & Oller, 1994; Watanabe & Koyama, 2008). From a validity standpoint, one area of investigation has been the extent to which cloze tests measure reading ability beyond the sentence level.…
Potential role of CS2 photooxidation in tropospheric sulfur chemistry
NASA Technical Reports Server (NTRS)
Wine, P. H.; Chameides, W. L.; Ravishankara, A. R.
1981-01-01
Absorption cross section measurements and model calculations indicate that CS2 photooxidation may be an important tropospheric sink for the CS2, giving a lifetime on the order of a week or two. If background CS2 levels are 10-20 pptv, then CS2 photooxidation may be an important global source of OCS as well.
The Early Development Index and Children from Culturally and Linguistically Diverse Backgrounds
ERIC Educational Resources Information Center
Li, Jianghong; D'Angiulli, Amedeo; Kendall, Garth E.
2007-01-01
The Early Development Index (EDI) is a teacher-completed checklist, intended to be a population-level tool to measure children's readiness for school and to alert communities to potential developmental problems in children. In response to the increasing popularity of the EDI, this paper provides a critical and timely evaluation and identifies the…
ERIC Educational Resources Information Center
Kouame, Julien B.
2010-01-01
Background: Readability tests are indicators that measure how easy a document can be read and understood. Simple, but very often ignored, readability statistics cannot only provide information about the level of difficulty of the readability of particular documents but also can increase an evaluator's credibility. Purpose: The purpose of this…
Recruiting a Diverse Group of Middle School Girls into the Trial of Activity for Adolescent Girls
ERIC Educational Resources Information Center
Elder, John P.; Shuler, LaVerne; Moe, Stacey G.; Grieser, Mira; Pratt, Charlotte; Cameron, Sandra; Hingle, Melanie; Pickrel, Julie L.; Saksvig, Brit I.; Schachter, Kenneth; Greer, Susan; Bothwell, Elizabeth K. Guth
2008-01-01
Background: School-based study recruitment efforts are both time consuming and challenging. This paper highlights the recruitment strategies employed by the national, multisite Trial of Activity for Adolescent Girls (TAAG), a study designed to measure the effectiveness of an intervention to reduce the decline of physical activity levels among…
The Differentiation of Adaptive Behaviours: Evidence from High and Low Performers
ERIC Educational Resources Information Center
Kane, Harrison; Oakland, Thomas David
2015-01-01
Background: Professionals who use measures of adaptive behaviour when working with special populations may assume that adaptive behaviour is a consistent and linear construct at various ability levels and thus believe the construct of adaptive behaviour is the same for high and low performers. That is, highly adaptive people simply are assumed to…
School-Based Screening of the Dietary Intakes of Third Graders in Rural Appalachian Ohio
ERIC Educational Resources Information Center
Hovland, Jana A.; McLeod, Sara M.; Duffrin, Melani W.; Johanson, George; Berryman, Darlene E.
2010-01-01
Background: Children in Appalachia are experiencing high levels of obesity, in large measure because of inferior diets. This study screened the dietary intake of third graders residing in 3 rural Appalachian counties in Ohio and determined whether the Food, Math, and Science Teaching Enhancement Resource Initiative (FoodMASTER) curriculum improved…
Ingestion of arsenic is the primary route of exposure for most people, with dietary intake and drinking water as the primary sources of that exposure. Traditionally, measurements of arsenic dietary intake are based on food consumption data coupled with total arsenic data from a ...
ERIC Educational Resources Information Center
Vashdi, E.; Hutzler, Y.; Roth, D.
2008-01-01
Background: Individuals with Intellectual Disability (ID) exhibit reduced levels of compliance to exercise, including treadmill walking. The purpose of this study was to measure the effects of several training conditions on compliance to participation in treadmill walking of children with moderate to severe ID. Method: Criteria for compliance were…
Cryogenic Laser Calorimetry for Impurity Analysis
NASA Technical Reports Server (NTRS)
Swimm, R. T.
1985-01-01
The results of a one-year effort to determine the applicability of laser-calorimetric spectroscopy to the study of deep-level impurities in silicon are presented. Critical considerations for impurity analysis by laser-calorimetric spectroscopy are discussed, the design and performance of a cryogenic laser calorimeter is described, and measurements of background absorption in high-purity silicon are presented.
ERIC Educational Resources Information Center
Malecki, Christine Kerres; Demaray, Michelle Kilpatrick; Coyle, Samantha; Geosling, Raymond; Rueger, Sandra Yu; Becker, Lisa Davidson
2015-01-01
Background: Bullying behavior is related to higher levels of internalizing distress and can be defined as including three aspects: frequency, intentionality, and power differential. However, bullying behavior is most often measured using only one aspect: frequency. Objective: The current study investigated the relative importance of several…
What Do Employers Pay for Employees' Complex Problem Solving Skills?
ERIC Educational Resources Information Center
Ederer, Peer; Nedelkoska, Ljubica; Patt, Alexander; Castellazzi, Silvia
2015-01-01
We estimate the market value that employers assign to the complex problem solving (CPS) skills of their employees, using individual-level Mincer-style wage regressions. For the purpose of the study, we collected new and unique data using psychometric measures of CPS and an extensive background questionnaire on employees' personal and work history.…
ERIC Educational Resources Information Center
Schoufour, Josje D.; Mitnitski, Arnold; Rockwood, Kenneth; Evenhuis, Heleen M.; Echteld, Michael A.
2013-01-01
Background: Although there is no strict definition of frailty, it is generally accepted as a state of high vulnerability for adverse health outcomes at older age. Associations between frailty and mortality, dependence, and hospitalization have been shown. We measured the frailty level of older people with intellectual disabilities (ID).…
ERIC Educational Resources Information Center
Lin, Haiqun; Katsovich, Liliya; Ghebremichael, Musie; Findley, Diane B.; Grantz, Heidi; Lombroso, Paul J.; King, Robert A.; Zhang, Heping; Leckman, James F.
2007-01-01
Background: The goals of this prospective longitudinal study were to monitor levels of psychosocial stress in children and adolescents with Tourette syndrome (TS) and/or obsessive-compulsive disorder (OCD) compared to healthy control subjects and to examine the relationship between measures of psychosocial stress and fluctuations in tic,…
ERIC Educational Resources Information Center
Huang, Francis L.; Cornell, Dewey G.; Konold, Timothy; Meyer, Joseph P.; Lacey, Anna; Nekvasil, Erin K.; Heilbrun, Anna; Shukla, Kathan D.
2015-01-01
Background: School climate is well recognized as an important influence on student behavior and adjustment to school, but there is a need for theory-guided measures that make use of teacher perspectives. Authoritative school climate theory hypothesizes that a positive school climate is characterized by high levels of disciplinary structure and…
Transparency of Vocational Qualifications: The Leonardo da Vinci Approach. CEDEFOP Panorama Series.
ERIC Educational Resources Information Center
Bjornavold, Jens; Pettersson, Sten
This report gives an overview of the situation of transparency of vocational qualifications by presenting measures introduced at the European Community level and by drawing attention to projects within the Leonardo da Vinci Program dealing with the issue. A 16-page executive summary appears first. Chapter 1 provides general background and aims.…
ERIC Educational Resources Information Center
Howie, Erin K.; Stevick, E. Doyle
2014-01-01
Background: Despite broad public support and legislative activity, policies intended to promote physical activity in schools have not produced positive outcomes in levels of physical activity or student health. What explains the broad failure of Physical Activity Policies (PAPs)? Thus far, PAP research has used limited quantitative methods to…
Qin, Xike; Liu, Bolin; Soulard, Jonathan; Morse, David; Cappadocia, Mario
2006-01-01
A method for the quantification of S-RNase levels in single styles of self-incompatible Solanum chacoense was developed and applied toward an experimental determination of the S-RNase threshold required for pollen rejection. It was found that, when single style values are averaged, accumulated levels of the S(11)- and S(12)-RNases can differ up to 10-fold within a genotype, while accumulated levels of the S(12)-RNase can differ by over 3-fold when different genotypes are compared. Surprisingly, the amount of S(12)-RNase accumulated in different styles of the same plant can differ by over 20-fold. A low level of 160 ng S-RNase in individual styles of fully incompatible plants, and a high value of 68 ng in a sporadic self-compatible (SSC) line during a bout of complete compatibility was measured, suggesting that these values bracket the threshold level of S-RNase needed for pollen rejection. Remarkably, correlations of S-RNase values to average fruit sets in different plant lines displaying sporadic self-compatibility (SSC) to different extents as well as to fruit set in immature flowers, are all consistent with a threshold value of 80 ng S(12)-RNase. Taken together, these results suggest that S-RNase levels alone are the principal determinant of the incompatibility phenotype. Interestingly, while the S-RNase threshold required for rejection of S(12)-pollen from a given genetic background is the same in styles of different genetic backgrounds, it is different when pollen donors of different genetic backgrounds are used. These results reveal a previously unsuspected level of complexity in the incompatibility reaction.
NASA Astrophysics Data System (ADS)
Vals, M.
2017-09-01
We use MAVEN/NGIMS CO2 density measurements to analyse gravity waves in the thermosphere of Mars. In particular the seasonal/latitudinal variability of their amplitude is studied and interpreted. Key background parameters controlling the activity of gravity waves are analysed with the help of the Mars Climate Database (MCD). Gravity waves activity presents a good anti-correlation to the temperature variability retrieved from the MCD. An analysis at pressure levels is ongoing.
Noguchi, M; Satoh, K; Higuchi, H
1984-12-01
Pulse shape discrimination of alpha and beta rays with liquid scintillation counting was investigated for the purpose of low level alpha activity measurements. Various liquid scintillators for pulse shape discrimination were examined by means of pulse rise time analysis. A new scintillator of low cost and of superior characteristics was found. The figure of merits better than 3.5 in rise time spectrum and the energy resolution better than 9% were obtained for carefully prepared samples. The background counting rate for a sample of 10 ml was reduced to 0.013 cpm/MeV in the range of alpha ray energy 5 to 7 MeV.
Fassett, William E
2011-10-10
As colleges and schools of pharmacy develop core courses related to patient safety, course-level outcomes will need to include both knowledge and performance measures. Three key performance outcomes for patient safety coursework, measured at the course level, are the ability to perform root cause analyses and healthcare failure mode effects analyses, and the ability to generate effective safety communications using structured formats such as the Situation-Background-Assessment-Recommendation (SBAR) situational briefing model. Each of these skills is widely used in patient safety work and competence in their use is essential for a pharmacist's ability to contribute as a member of a patient safety team.
Atmospheric Radioxenon Measurements in North Las Vegas, NV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milbrath, Brian D.; Cooper, Matthew W.; Lidey, Lance S.
2006-07-31
PNNL deployed the ARSA radioxenon measurement system in North Las Vegas for two weeks in February and March 2006 for the purpose of measuring the radioxenon background at a level of sensitivity much higher than previously done in the vicinity of the NTS. The measurements establish what might be expected if future measurements are taken at NTS itself. The measurements are also relevant to test site readiness. A second detector, the PEMS, built and operated by DRI, was deployed in conjunction with the ARSA and contained a PIC, aerosol collection filters, and meteorological sensors. Originally, measurements were also to bemore » performed at Mercury, NV on the NTS, but these were canceled due to initial equipment problems with the ARSA detector. Some of the radioxenon measurements detected 133Xe at levels up to 3 mBq/m3. This concentration of radioxenon is consistent with the observation of low levels of radioxenon emanating from distance nuclear reactors. Previous measurements in areas of high nuclear reactor concentration have shown similar results, but the western US, in general, does not have many nuclear reactors. Measurements of the wind direction indicate that the air carrying the radioxenon came from south of the detector and not from the NTS.« less
NASA Technical Reports Server (NTRS)
Burley, R. R.
1974-01-01
To establish a realistic lower limit for the noise level of advanced supersonic transport aircraft will require knowledge concerning the amount of noise generated by the airframe itself as it moves through the air. The airframe noise level of an F-106B aircraft was determined and was compared to that predicted from an existing empirical relationship. The data were obtained from flyover and static tests conducted to determine the background noise level of the F-106B aircraft. Preliminary results indicate that the spectrum associated with airframe noise was broadband and peaked at a frequency of about 570 hertz. An existing empirical method successfully predicted the frequency where the spectrum peaked. However, the predicted OASPL value of 105 db was considerably greater than the measures value of 83 db.
Exogenous Supply of Pantoyl Lactone to Excised Leaves Increases their Pantothenate Levels
RATHINASABAPATHI, BALA; RAMAN, SURESH BABU
2005-01-01
• Background and Aims All plants synthesize pantothenate but its synthesis and regulation are not well understood. The aim of this work is to study the effect of exogenous supply of precursor compounds on pantothenate levels in leaves. • Methods Precursor compounds were supplied in solution to excised leaves and the pantothenate content was measured using a microbial method. • Key Results Pantothenate levels in excised leaves of Limonium latifolium, tomato (Lycopersicon esculentum), bean (Phaseolus vulgaris) and grapefruit (Citrus × paradisi) were examined following an exogenous supply of the precursor compounds pantoyl lactone or β-alanine. Significantly higher levels of extractable pantothenate were found when pantoyl lactone was supplied, but not when β-alanine was supplied despite a measurable uptake of β-alanine into the leaf. • Conclusions The results suggested that the pantoate supply may be rate-limiting or regulating pantothenate synthesis in leaves. PMID:15767268
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. R. Saffle; R. G. Mitchell; R. B. Evans
The results of the various monitoring programs for 1998 indicated that radioactivity from the DOE's Idaho National Engineering and Environmental Laboratory (INEEL) operations could generally not be distinguished from worldwide fallout and natural radioactivity in the region surrounding the INEEL. Although some radioactive materials were discharged during INEEL operations, concentrations in the offsite environment and doses to the surrounding population were far less than state of Idaho and federal health protection guidelines. Gross alpha and gross beta measurements, used as a screening technique for air filters, were investigated by making statistical comparisons between onsite or boundary location concentrations and themore » distant community group concentrations. Gross alpha activities were generally higher at distant locations than at boundary and onsite locations. Air samples were also analyzed for specific radionuclides. Some human-made radionuclides were detected at offsite locations, but most were near the minimum detectable concentration and their presence was attributable to natural sources, worldwide fallout, and statistical variations in the analytical results rather than to INEEL operations. Low concentrations of 137Cs were found in muscle tissue and liver of some game animals and sheep. These levels were mostly consistent with background concentrations measured in animals sampled onsite and offsite in recent years. Ionizing radiation measured simultaneously at the INEEL boundary and distant locations using environmental dosimeters were similar and showed only background levels. The maximum potential population dose from submersion, ingestion, inhalation, and deposition to the approximately 121,500 people residing within an 80-km (50-mi) radius from the geographical center of the INEEL was estimated to be 0.08 person-rem (8 x 10-4 person-Sv) using the MDIFF air dispersion model. This population dose is less than 0.0002 percent of the estimated 43,7 00 person-rem (437 person-Sv) population dose from background radioactivity.« less
Desktop publishing and validation of custom near visual acuity charts.
Marran, Lynn; Liu, Lei; Lau, George
2008-11-01
Customized visual acuity (VA) assessment is an important part of basic and clinical vision research. Desktop computer based distance VA measurements have been utilized, and shown to be accurate and reliable, but computer based near VA measurements have not been attempted, mainly due to the limited spatial resolution of computer monitors. In this paper, we demonstrate how to use desktop publishing to create printed custom near VA charts. We created a set of six near VA charts in a logarithmic progression, 20/20 through 20/63, with multiple lines of the same acuity level, different letter arrangements in each line and a random noise background. This design allowed repeated measures of subjective accommodative amplitude without the potential artifact of familiarity of the optotypes. The background maintained a constant and spatial frequency rich peripheral stimulus for accommodation across the six different acuity levels. The paper describes in detail how pixel-wise accurate black and white bitmaps of Sloan optotypes were used to create the printed custom VA charts. At all acuity levels, the physical sizes of the printed custom optotypes deviated no more than 0.034 log units from that of the standard, satisfying the 0.05 log unit ISO criterion we used to demonstrate physical equivalence. Also, at all acuity levels, log unit differences in the mean target distance for which reliable recognition of letters first occurred for the printed custom optotypes compared to the standard were found to be below 0.05, satisfying the 0.05 log unit ISO criterion we used to demonstrate functional equivalence. It is possible to use desktop publishing to create custom near VA charts that are physically and functionally equivalent to standard VA charts produced by a commercial printing process.
Variability in regional background aerosols within the Mediterranean
NASA Astrophysics Data System (ADS)
Querol, X.; Alastuey, A.; Pey, J.; Cusack, M.; Pérez, N.; Mihalopoulos, N.; Theodosi, C.; Gerasopoulos, E.; Kubilay, N.; Koçak, M.
2009-04-01
The main objective of this study is the identification of major factors controlling levels and chemical composition of aerosols in the regional background (RB) along the Mediterranean Basin (MB). To this end, data on PM levels and speciation from Montseny (MSY, Northeastern Spain), Finokalia (FKL, Southern Greece) and Erdemli (ERL, Southern Turkey) for the period 2001 to 2008 are evaluated. Important differences on PM levels and composition are evident when comparing the Western and Eastern MBs. The results manifest W-E and N-S PM10 and PM2.5 gradients along the MB, attributed to the higher frequency and intensity of African dust outbreaks in the EMB, while for PM1 very similar levels are encountered. PM in the EMB is characterized by higher levels of crustal material and sulphate as compared to WMB (and central European sites), however, RB nitrate and OC+EC levels are relatively constant across the Mediterranean and lower than other European sites. Marked seasonal trends are evidenced for PM levels, nitrate (WMB), ammonium and sulphate. Also relatively higher levels of V and Ni (WMB) are measured in the Mediterranean basin, probably as a consequence of high emissions from fuel-oil combustion (power generation, industrial and shipping emissions). Enhanced sulphate levels in EMB compared to WMB were measured. The high levels of sulphate in the EMB may deplete the available gas-phase NH3 so that little ammonium nitrate can form due to the low NH3 levels. This study illustrates the existence of three very important features within the Mediterranean that need to be accounted for when modeling climate effects of aerosols in the area, namely: (a) the increasing gradient of dust from WMB to EMB; (b) the change of hygroscopic behavior of mineral aerosols (dust) via nitration and sulphation; and (c) the abundance of highly hygroscopic aerosols during high insolation (low cloud formation) periods.
Variability in regional background aerosols within the Mediterranean
NASA Astrophysics Data System (ADS)
Querol, X.; Alastuey, A.; Pey, J.; Cusack, M.; Pérez, N.; Mihalopoulos, N.; Theodosi, C.; Gerasopoulos, E.; Kubilay, N.; Koçak, M.
2009-07-01
The main objective of this study is the identification of major factors controlling levels and chemical composition of aerosols in the regional background (RB) along the Mediterranean Basin (MB). To this end, data on PM levels and speciation from Montseny (MSY, NE Spain), Finokalia (FKL, Southern Greece) and Erdemli (ERL, Southern Turkey) for the period 2001 to 2008 are evaluated. Important differences on PM levels and composition are evident when comparing the Western and Eastern MBs. The results manifest W-E and N-S PM10 and PM2.5 gradients along the MB, attributed to the higher frequency and intensity of African dust outbreaks in the EMB, while for PM1 very similar levels are encountered. PM in the EMB is characterized by higher levels of crustal material and sulphate as compared to WMB (and central European sites), however, RB nitrate and OC + EC levels are relatively constant across the Mediterranean and lower than other European sites. Marked seasonal trends are evidenced for PM levels, nitrate (WMB), ammonium and sulphate. Also relatively higher levels of V and Ni (WMB) are measured in the Mediterranean basin, probably as a consequence of high emissions from fuel-oil combustion (power generation, industrial and shipping emissions). Enhanced sulphate levels in EMB compared to WMB were measured. The high levels of sulphate in the EMB may deplete the available gas-phase NH3 so that little ammonium nitrate can form due to the low NH3 levels. This study illustrates the existence of three very important features within the Mediterranean that need to be accounted for when modeling climate effects of aerosols in the area, namely: a) the increasing gradient of dust from WMB to EMB; b) the change of hygroscopic behavior of mineral aerosols (dust) via nitration and sulfation; and c) the abundance of highly hygroscopic aerosols during high insolation (low cloud formation) periods.
NASA Astrophysics Data System (ADS)
Pondthai, P.; Udphuay, S.
2013-05-01
The magnitude of 5.1 Mw earthquake occurred in San Sai District, Chiang Mai Province, Thailand in December 2006 was considered an uncommon event due to the fact that there was no statistical record of such significant earthquake in the area. Therefore the earthquake might have been associated with a potentially active fault zone within the area. The objective of this study is to measure soil gas radon across this unknown fault zone within the Chiang Mai Basin, northern Thailand. Two profiles traversing the expected fault zone of soil gas radon measurements have been monitored, using TASTRAK solid state track nuclear detectors (SSNTDs). Radon signals from three periods of measurement show a distinctive consistent spatial distribution pattern. Anomalous radon areas along the profiles are connected to fault locations previously interpreted from other geophysical survey results. The increased radon signal changes from the radon background level with the signal-to-background ratio above 3 are considered anomalous. Such pattern of radon anomaly supports the existence of the faults. The radon measurement, therefore is a powerful technique in mapping active fault zone.
The calorimeter of the Mu2e experiment at Fermilab
Atanov, N.; Baranov, V.; Budagov, J.; ...
2017-01-23
Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: amore » straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10 -4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.« less
[Working environment measurement of radioactive substances].
Kunugita, Naoki
2007-12-01
The control of the working environment is one of the most important duties in any working place to prevent occupational disease. In Japan, in the case of the controlled area using unsealed radioisotopes, the measurement of the concentration of airborne radioactive substances should be carried out under the regulations of the "Industrial Safety and Health Law" and the "Ordinance on Prevention of Ionizing Radiation Hazards". Many reports showed that the results of regular working environment measurements of radioactive substances were about background levels. Safe working environments are sufficiently guaranteed by a suitable estimation and handling under the strict regulation by the "Laws Concerning the Prevention from Radiation Hazards Due to Radioisotopes and Others". The regulation by "Ordinance on Prevention of Ionizing Radiation Hazards" would be relaxed in the field of education and research, which use very low quantities of radioactive substances, in ways such as estimation by calculation in place of the actual measurement, decrease of the number of monthly measurements, and measurement exemption for low levels of isotopes.
2013-01-01
Background Two of the current methodological barriers to implementation science efforts are the lack of agreement regarding constructs hypothesized to affect implementation success and identifiable measures of these constructs. In order to address these gaps, the main goals of this paper were to identify a multi-level framework that captures the predominant factors that impact implementation outcomes, conduct a systematic review of available measures assessing constructs subsumed within these primary factors, and determine the criterion validity of these measures in the search articles. Method We conducted a systematic literature review to identify articles reporting the use or development of measures designed to assess constructs that predict the implementation of evidence-based health innovations. Articles published through 12 August 2012 were identified through MEDLINE, CINAHL, PsycINFO and the journal Implementation Science. We then utilized a modified five-factor framework in order to code whether each measure contained items that assess constructs representing structural, organizational, provider, patient, and innovation level factors. Further, we coded the criterion validity of each measure within the search articles obtained. Results Our review identified 62 measures. Results indicate that organization, provider, and innovation-level constructs have the greatest number of measures available for use, whereas structural and patient-level constructs have the least. Additionally, relatively few measures demonstrated criterion validity, or reliable association with an implementation outcome (e.g., fidelity). Discussion In light of these findings, our discussion centers on strategies that researchers can utilize in order to identify, adapt, and improve extant measures for use in their own implementation research. In total, our literature review and resulting measures compendium increases the capacity of researchers to conceptualize and measure implementation-related constructs in their ongoing and future research. PMID:23414420
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollmann, E. M.; Yu, J. H.; Doerner, R. P.
2015-09-14
The thermionic electron emission current emitted from a laser-produced hot spot on a tungsten target in weakly-ionized deuterium plasma is measured. It is found to be one to two orders of magnitude larger than expected for bipolar space charge limited thermionic emission current assuming an unperturbed background plasma. This difference is attributed to the plasma being modified by ionization of background neutrals by the emitted electrons. This result indicates that the allowable level of emitted thermionic electron current can be significantly enhanced in weakly-ionized plasmas due to the presence of large neutral densities.
Ambient Dose Equivalent in S. Paulo and Bauru cities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umisedo, Nancy K.; Okuno, Emico; Cancio, Francisco S.
2008-08-07
The Laboratory of Dosimetry (Institute of Physics, University of S. Paulo) performs since 1981 the external individual monitoring of workers exposed to X and gamma rays based on thermoluminescent dosimetry (TLD). Personal dose equivalent refers only to the exposure of workers due to the working activities, and the dose due to background radiation, also measured with TLD, must be subtracted to evaluate it. A compilation of ambient dose equivalent was done to evaluate the dose due to the background radiation in the work places, and also to contribute to the knowledge of the level of indoor radiation to which themore » public is exposed.« less
NASA Astrophysics Data System (ADS)
Tkaczyk, A. H.; Saare, H.; Ipbüker, C.; Schulte, F.; Mastinu, P.; Paepen, J.; Pedersen, B.; Schillebeeckx, P.; Varasano, G.
2018-02-01
This paper describes the characterization of commercially available plastic scintillation detectors to be used as an active shield or veto system to reduce the neutron background resulting from atmospheric muon interactions in low-level nuclear waste assay systems. The shield consists of an array of scintillation detectors surrounding a neutron detection system. Scintillation detectors with different thicknesses are characterized for their response to gamma rays, neutrons, and muons. Response functions to gamma rays were determined and measured in the energy range from 0.6 MeV to 6.0 MeV using radionuclide sources. Neutron response functions were derived from results of time-of-flight measurements at the Van de Graaff accelerator of the INFN Legnaro and from measurements with quasi mono-energetic neutron beams produced at the Van de Graaff accelerator of the JRC Geel. From these data, the light output and resolution functions for protons and electrons were derived. The response to muons was verified by background measurements, i.e. without the presence of any neutron or gamma source. It was found that the muon peak is more pronounced when the detectors are placed horizontally. The results indicate that a scintillator with a minimum thickness of 20 mm is needed to separate events due to atmospheric muons from natural gamma ray background, and contributions due to neutron production in nuclear waste based on only the total energy deposition in the detector. In addition, it was shown that muons can be identified with a coincidence pattern when the detectors are stacked. The effectiveness of the proposed system was demonstrated based on muon induced spallation reactions in a lead sample.
Quantized correlation coefficient for measuring reproducibility of ChIP-chip data.
Peng, Shouyong; Kuroda, Mitzi I; Park, Peter J
2010-07-27
Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip) is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. We develop the Quantized correlation coefficient (QCC) that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization), a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.
Harmsen, Hans; Bernsen, Roos; Meeuwesen, Ludwien; Thomas, Siep; Dorrenboom, Govert; Pinto, David; Bruijnzeels, Marc
2005-05-01
Due to worldwide migration to Western countries, physicians are increasingly encountering patients with different ethnic backgrounds. Communication problems can arise as a result of differences in cultural backgrounds and poor language proficiency. To assess the effectiveness of an educational intervention on intercultural communication aimed to decrease inequalities in care provided between Western and non-Western patients. A randomised controlled trial with randomisation at the GP level and outcome measurements at the patient level. General practice in Rotterdam. Thirty-eight Dutch GPs in the Rotterdam region, with at least 25% of inhabitants of non-Western origin, and 2407 visiting patients were invited to participate in the study. A total of 986 consultations were finally included. The GPs were educated about cultural differences and trained in intercultural communication. Patients received a videotaped instruction focusing on how to communicate with their GP in a direct way. The primary outcome measure was mutual understanding and the secondary outcomes were patient's satisfaction and perceived quality of care. The intervention effect was assessed for all patients together, for the 'Western' and 'non-Western' patients, and for patients with different cultural backgrounds separately. An intervention effect was seen 6 months after the intervention, as improvement in mutual understanding (and some improvement in perceived quality of care) in consultations with 'non-Western' patients. A double intervention on intercultural communication given to both physician and patient decreases the gap in quality of care between 'Western' and 'non-Western' patients.
Colour blindness of the movement-detecting system of the spider Cupiennius salei.
Orlando, Eva; Schmid, Axel
2011-02-15
The nocturnal wandering spider Cupiennius salei has one pair of principal eyes and three pairs of secondary eyes located on the prosoma, which differ in both morphology and function. Their spectral sensitivity, measured with intracellular recordings, is due to three different types of photoreceptors with absorbance maxima in the mid-range of the spectrum, at 480 nm and 520 nm and in the UV at 360 nm. Based on these physiological data colour vision might be possible. In the present study, the ability to discriminate coloured moving stimuli from grey backgrounds was tested. The perception of moving coloured stripes in front of backgrounds with 29 different grey levels was measured by using extracellular recordings from the anterior median eye muscles as a monitoring system. Each of these eyes has two muscles, which increase their activity when moving stimuli are presented in front of a secondary eye. This variation in eye muscle activity can be recorded extracellulary in a living spider using a single channel telemetry device. If colour perception exists, the animal should be able to detect a moving coloured stripe in front of any grey level. Blue, green and red stripes were used as moving stimuli, in front of all 29 grey backgrounds. The results indicate that C. salei is not able to discriminate the coloured stimuli from distinct shades of grey. It is therefore evident that the movement-detecting system in this spider appears to be colour blind.
NASA Technical Reports Server (NTRS)
Flamant, Cyrille N.; Schwemmer, Geary K.; Korb, C. Laurence; Evans, Keith D.; Palm, Stephen P.
1999-01-01
Remote airborne measurements of the vertical and horizontal structure of the atmospheric pressure field in the lower troposphere are made with an oxygen differential absorption lidar (DIAL). A detailed analysis of this measurement technique is provided which includes corrections for imprecise knowledge of the detector background level, the oxygen absorption fine parameters, and variations in the laser output energy. In addition, we analyze other possible sources of systematic errors including spectral effects related to aerosol and molecular scattering interference by rotational Raman scattering and interference by isotopic oxygen fines.
Diode-laser-based RIMS measurements of strontium-90
NASA Astrophysics Data System (ADS)
Bushaw, B. A.; Cannon, B. D.
1998-12-01
Double- and triple-resonance excitation schemes for the ionization of strontium are presented. Use of single-mode diode lasers for the resonance excitations provides a high degree of optical isotopic selectivity: with double-resonance, selectivity of >104 for 90Sr against the stable Sr isotopes has been demonstrated. Measurement of lineshapes and stable isotope shifts in the triple-resonance process indicate that optical selectivity should increase to ˜109. When combined with mass spectrometer selectivity this is sufficient for measurement of 90Sr at background environmental levels. Additionally, autoionizing resonances have been investigated for improving ionization efficiency with lower power lasers.
NASA Astrophysics Data System (ADS)
Silva, James
2017-09-01
The Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering (CE νNS) using metallic superconducting and germanium semi-conducting detectors with sub-keV thresholds placed near a neutrino source such as the Chooz Nuclear Reactor Complex. In this poster, we present an estimate of the flux of cosmic-ray induced neutrons, which represent an important background in any (CE νNS) search, based on reconstructed cosmic ray data from the Chooz Site. We have simulated a possible Ricochet deployment at the Chooz site in GEANT4 focusing on the spallation neutrons generated when cosmic rays interact with the water tank veto that would surround our detector. We further simulate and discuss the effectiveness of various shielding configurations for optimizing the background levels for a future Ricochet deployment.
NASA Technical Reports Server (NTRS)
Fischer, M. L.; Alsop, D. C.; Cheng, E. S.; Clapp, A. C.; Cottingham, D. A.; Gundersen, J. O.; Koch, T. C.; Kreysa, E.; Meinhold, P. R.; Lange, A. E.
1992-01-01
We report the performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0 deg 3 min to 3 deg. The system represents a collaborative effort combining a low-background 1 m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3 (90), 6 (180), 9 (270), and 12 (360) cm(exp -1) (GHz). The telescope was flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of Delta(T)/T(sub CMB) is approximately equal to 10(exp -5) with detectors operated at T = 0.3 K.
Effects of interior aircraft noise on speech intelligibility and annoyance
NASA Technical Reports Server (NTRS)
Pearsons, K. S.; Bennett, R. L.
1977-01-01
Recordings of the aircraft ambiance from ten different types of aircraft were used in conjunction with four distinct speech interference tests as stimuli to determine the effects of interior aircraft background levels and speech intelligibility on perceived annoyance in 36 subjects. Both speech intelligibility and background level significantly affected judged annoyance. However, the interaction between the two variables showed that above an 85 db background level the speech intelligibility results had a minimal effect on annoyance ratings. Below this level, people rated the background as less annoying if there was adequate speech intelligibility.
A Background Noise Reduction Technique Using Adaptive Noise Cancellation for Microphone Arrays
NASA Technical Reports Server (NTRS)
Spalt, Taylor B.; Fuller, Christopher R.; Brooks, Thomas F.; Humphreys, William M., Jr.; Brooks, Thomas F.
2011-01-01
Background noise in wind tunnel environments poses a challenge to acoustic measurements due to possible low or negative Signal to Noise Ratios (SNRs) present in the testing environment. This paper overviews the application of time domain Adaptive Noise Cancellation (ANC) to microphone array signals with an intended application of background noise reduction in wind tunnels. An experiment was conducted to simulate background noise from a wind tunnel circuit measured by an out-of-flow microphone array in the tunnel test section. A reference microphone was used to acquire a background noise signal which interfered with the desired primary noise source signal at the array. The technique s efficacy was investigated using frequency spectra from the array microphones, array beamforming of the point source region, and subsequent deconvolution using the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) algorithm. Comparisons were made with the conventional techniques for improving SNR of spectral and Cross-Spectral Matrix subtraction. The method was seen to recover the primary signal level in SNRs as low as -29 dB and outperform the conventional methods. A second processing approach using the center array microphone as the noise reference was investigated for more general applicability of the ANC technique. It outperformed the conventional methods at the -29 dB SNR but yielded less accurate results when coherence over the array dropped. This approach could possibly improve conventional testing methodology but must be investigated further under more realistic testing conditions.
Kuntasal, Oznur Oğuz; Kilavuz, Seda Aslan; Karman, Deniz; Wang, Daniel; Tuncel, Gürdal
2013-10-01
Concentrations of 91 volatile organic compounds (VOCs) ranging from C5 to C12 were measured at three sites in Ankara, the capital of Turkey, in the summer of 2003 and winter of 2004. Samples were collected at roadside, residential and background stations at consecutive 4-hr intervals over a 24-hr period for six weeks in each season. Air samples were collected onto cartridges packed with Tenax TA and Carbopack B resins and analyzed by thermal desorption, followed by gas chromatography coupled to a mass selective detector (GC/MSD). Time resolved data provided information on ambient levels, temporal and spatial variations and sources of VOCs in Ankara. Toluene is the most abundant compound at all sites with and average concentration of 13.1 ?g m(-3). The mean concentrations of benzene are 12.6, 5.2, and 2.4 ?g m(-3) during winter at roadside, residential and background stations, respectively. Diurnal variation in the data together with toluene to benzene concentration ratio (T:B) that is close to 2.0 indicated the influence of traffic related emissions at residential and roadside stations during winter season. Higher T:B ratio observed at residential and background stations during summer period and correlation analysis indicated additional VOC sources. Temporal variations and low m,p-xylene to ethylbenzene ratio (mpX:E) indicated that transported air mass is the major VOC source influencing VOC concentrations measured at the background station.
Modeling radon daughter deposition rates for low background detectors
NASA Astrophysics Data System (ADS)
Westerdale, S.; Guiseppe, V. E.; Rielage, K.; Elliot, S. R.; Hime, A.
2009-10-01
Detectors such as those looking for dark matter and those working to detect neutrinoless double-beta decay require record low levels of background radiation. One major source of background radiation is from radon daughters that decay from airborne radon. In particular, ^222Rn decay products may be deposited on any detector materials that are exposed to environmental radon. Long-lasting daughters, especially ^210Pb, can pose a long-term background radiation source that can interfere with the detectors' measurements by emitting alpha particles into sensitive parts of the detectors. A better understanding of this radon daughter deposition will allow for preventative actions to be taken to minimize the amount of noise from this source. A test stand has therefore been set up to study the impact of various environmental factors on the rate of radon daughter deposition so that a model can be constructed. Results from the test stand and a model of radon daughter deposition will be presented.
[Mental health of Polish immigrants compared to that of the Polish and German populations].
Morawa, Eva; Senf, Wolfgang; Erim, Yesim
2013-01-01
This survey examines the mental health of immigrants of Polish origin compared to samples from the Polish and German populations. In a sample of 513 subjects (261 persons with Polish migration background and 252 autochthone Poles) depression (BDI), anxiety (BAI), and somatic complaints (GBB-24) were measured. Immigrants of Polish origin showed a significantly higher level of anxiety as well as somatic complaints but only a tendency toward higher depressiveness than the German normvalue, but not than that of the native Poles. Female immigrants showed an overall higher number of symptoms in the three domains in question compared to German women and - except for depressiveness - also compared to male immigrants. Persons with a Polish migration background present levels of mental distress higher than the general German population, but similar to the population of their country of origin. Further research is needed to clarify the special structure of the mental morbidity in Polish immigrants.
Balaswamy, S; Richardson, V E
2001-01-01
A multidimensional Life Stress Model was used to test the independent contributions of background characteristics, personal resources, life event, and environmental influences on 200 widowers' levels of well-being, measured by the Affect Balance Scale. Stepwise regression analyses revealed that environmental resources were unrelated to negative affect which is influenced more by the life event and personal resource variables. The environmental resource variables, particularly interactions with friends and neighbors, mostly influenced positive affect. The explanatory model for well-being included multiple variables and explained 33 percent of the variance. Although background characteristics had the greatest impact, absence of hospitalization, higher mastery, higher self-esteem, contacts with friends, and interaction with neighbors enhanced well-being. The results support previous speculations on the importance of positive exchanges for positive affect. African-American widowers showed higher levels of well-being than Caucasian widowers did. The results advance knowledge about differences among elderly men.
Cvikl, Barbara; Haubenberger-Praml, Gertraud; Drabo, Petra; Hagmann, Michael; Gruber, Reinhard; Moritz, Andreas; Nell, Andrea
2014-05-09
A low level of education and the migration background of parents are associated with the development of caries in children. The aim of this study was to evaluate whether a higher educational level of parents can overcome risks for the development of caries in immigrants in Vienna, Austria. The educational level of the parents, the school type, and the caries status of 736 randomly selected twelve-year-old children with and without migration background was determined in this cross sectional study. In children attending school in Vienna the decayed, missing, and filled teeth (DMFT) index was determined. For statistical analysis, a mixed negative-binomial-model was used. The caries status of the children with migration background was significantly worse compared to that of the native Viennese population. A significant interaction was found between migration background and the educational level of the parents (p = 0.045). No interaction was found between the school type and either the migration background (p = 0.220) or the education level of the parents (p = 0.08). In parents with a higher scholarly education level, migration background (p < 0.01) and school type (p = 0.018) showed an association with DMFT values. In parents with a low education level, however, migration background and school type had no significant association with DMFT values. These data indicate that children with a migration background are at higher risk to acquire caries than other Viennese children, even when the parents have received a higher education.
Observations of Europe wide Trends in background and peak O3, CO and NO2 levels
NASA Astrophysics Data System (ADS)
Fleming, Z. L.; Monks, P. S.; Brunsdon, C.; Henne, S.; Buchmann, B.; Konovalov, I.; Beekman, M.
2009-04-01
The GEOMON (Global Earth Observation and MONitoring) project has produced a harmonised data set of trace gases from various ground-based measurement stations. These stations belong to a variety of regional, national and European air quality networks (e.g. EMEP, GAW). Investigations into instrumental calibration and data quality have been carried out in order to make comparison between the sites as accurate as possible for a long time-scale trend analysis. Ozone seasonal cycles at the various sites have been compared, showing characteristic cycles according to latitude, elevation, vicinity to coastal areas and pollution sources and population nearby. A de-trending of this seasonal cycle revealed long-term variations in ozone and a considerable difference between background and peak ozone trends between sites. National, European and international legislation has aimed at reducing CO and NO2 and correspondingly, reduce O3 levels over the last 20 years but the trends are not as clear cut and reveal that there is not a homogeneous reduction in these species across Europe. Splitting the data into seasonal periods and also into lower and upper concentration percentiles shows us more clearly how the species vary across Europe. There is a tendency for peak ozone levels to decrease, whilst the background levels have mostly increased. Averages, lower and upper percentiles of these species at the GEOMON stations are shown on European maps and the distribution of annual ozone trends is evaluated. Comparisons with models that estimate the lower and upper percentiles of ozone during summer overestimate ozone levels but not uniformly across Europe.
Sanusi, M S M; Ramli, A T; Hassan, W M S W; Lee, M H; Izham, A; Said, M N; Wagiran, H; Heryanshah, A
2017-07-01
Kuala Lumpur has been undergoing rapid urbanisation process, mainly in infrastructure development. The opening of new township and residential in former tin mining areas, particularly in the heavy mineral- or tin-bearing alluvial soil in Kuala Lumpur, is a contentious subject in land-use regulation. Construction practices, i.e. reclamation and dredging in these areas are potential to enhance the radioactivity levels of soil and subsequently, increase the existing background gamma radiation levels. This situation is worsened with the utilisation of tin tailings as construction materials apart from unavoidable soil pollutions due to naturally occurring radioactive materials in construction materials, e.g. granitic aggregate, cement and red clay brick. This study was conducted to assess the urbanisation impacts on background gamma radiation in Kuala Lumpur. The study found that the mean value of measured dose rate was 251±6nGyh -1 (156-392nGyh -1 ) and 4 times higher than the world average value. High radioactivity levels of 238 U (95±12Bqkg -1 ), 232 Th (191±23Bqkg -1 ,) and 40 K (727±130Bqkg -1 ) in soil were identified as the major source of high radiation exposure. Based on statistical ANOVA, t-test, and analyses of cumulative probability distribution, this study has statistically verified the dose enhancements in the background radiation. The effective dose was estimated to be 0.31±0.01mSvy -1 per man. The recommended ICRP reference level (1-20mSvy -1 ) is applicable to the involved existing exposure situation in this study. The estimated effective dose in this study is lower than the ICRP reference level and too low to cause deterministic radiation effects. Nevertheless based on estimations of lifetime radiation exposure risks, this study found that there was small probability for individual in Kuala Lumpur being diagnosed with cancer and dying of cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.
Measuring the power spectrum of dark matter substructure using strong gravitational lensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hezaveh, Yashar; Dalal, Neal; Holder, Gilbert
2016-11-01
In recent years, it has become possible to detect individual dark matter subhalos near images of strongly lensed extended background galaxies. Typically, only the most massive subhalos in the strong lensing region may be detected this way. In this work, we show that strong lenses may also be used to constrain the much more numerous population of lower mass subhalos that are too small to be detected individually. In particular, we show that the power spectrum of projected density fluctuations in galaxy halos can be measured using strong gravitational lensing. We develop the mathematical framework of power spectrum estimation, andmore » test our method on mock observations. We use our results to determine the types of observations required to measure the substructure power spectrum with high significance. We predict that deep observations (∼10 hours on a single target) with current facilities can measure this power spectrum at the 3σ level, with no apparent degeneracy with unknown clumpiness in the background source structure or fluctuations from detector noise. Upcoming ALMA measurements of strong lenses are capable of placing strong constraints on the abundance of dark matter subhalos and the underlying particle nature of dark matter.« less
2012-01-01
Background Psychiatric outpatients with a refugee background have often been exposed to a variety of potentially traumatizing events, with numerous negative consequences for their mental health and quality of life. However, some patients also report positive personal changes, posttraumatic growth, related to these potentially traumatic events. This study describes posttraumatic growth, posttraumatic stress symptoms, depressive symptoms, post-migration stressors, and their association with quality of life in an outpatient psychiatric population with a refugee background in Norway. Methods Fifty five psychiatric outpatients with a refugee background participated in a cross-sectional study using clinical interviews to measure psychopathology (SCID-PTSD, MINI), and four self-report instruments measuring posttraumatic growth, posttraumatic stress symptoms, depressive symptoms, and quality of life (PTGI-SF, IES-R, HSCL-25-depression scale, and WHOQOL-Bref) as well as measures of social integration, social network and employment status. Results All patients reported some degree of posttraumatic growth, while only 31% reported greater amounts of growth. Eighty percent of the patients had posttraumatic stress symptoms above the cut-off point, and 93% reported clinical levels of depressive symptoms. Quality of life in the four domains of the WHOQOL-Bref levels were low, well below the threshold for the’life satisfaction’ standard proposed by Cummins. A hierarchic regression model including depressive symptoms, posttraumatic stress symptoms, posttraumatic growth, and unemployment explained 56% of the total variance found in the psychological health domain of the WHOQOL-Bref scale. Posttraumatic growth made the strongest contribution to the model, greater than posttraumatic stress symptoms or depressive symptoms. Post-migration stressors like unemployment, weak social network and poor social integration were moderately negatively correlated with posttraumatic growth and quality of life, and positively correlated with psychopathological symptoms. Sixty percent of the outpatients were unemployed. Conclusions Multi-traumatized refugees in outpatient clinics reported both symptoms of psychopathology and posttraumatic growth after exposure to multiple traumatic events. Symptoms of psychopathology were negatively related to the quality of life, and positively related to post-migration stressors such as unemployment, weak social network and poor social integration. Posttraumatic growth was positively associated with quality of life, and negatively associated with post-migration stressors. Hierarchical regression modeling showed that posttraumatic growth explained more of the variance in quality of life than did posttraumatic stress symptoms, depressive symptoms or unemployment. It may therefore be necessary to address both positive changes and psychopathological symptoms when assessing and treating multi-traumatized outpatients with a refugee background. PMID:22824521
Damian, Rodica Ioana; Su, Rong; Shanahan, Michael; Trautwein, Ulrich; Roberts, Brent W
2015-09-01
This study investigated the interplay of family background and individual differences, such as personality traits and intelligence (measured in a large U.S. representative sample of high school students; N = 81,000) in predicting educational attainment, annual income, and occupational prestige 11 years later. Specifically, we tested whether individual differences followed 1 of 3 patterns in relation to parental socioeconomic status (SES) when predicting attained status: (a) the independent effects hypothesis (i.e., individual differences predict attainments independent of parental SES level), (b) the resource substitution hypothesis (i.e., individual differences are stronger predictors of attainments at lower levels of parental SES), and (c) the Matthew effect hypothesis (i.e., "the rich get richer"; individual differences are stronger predictors of attainments at higher levels of parental SES). We found that personality traits and intelligence in adolescence predicted later attained status above and beyond parental SES. A standard deviation increase in individual differences translated to up to 8 additional months of education, $4,233 annually, and more prestigious occupations. Furthermore, although we did find some evidence for both the resource substitution and the Matthew effect hypotheses, the most robust pattern across all models supported the independent effects hypothesis. Intelligence was the exception, the interaction models being more robust. Finally, we found that although personality traits may help compensate for background disadvantage to a small extent, they do not usually lead to a "full catch-up" effect, unlike intelligence. This was the first longitudinal study of status attainment to test interactive models of individual differences and background factors. (c) 2015 APA, all rights reserved).
Damian, Rodica Ioana; Su, Rong; Shanahan, Michael; Trautwein, Ulrich; Roberts, Brent W.
2014-01-01
This paper investigates the interplay of family background and individual differences, such as personality traits and intelligence (measured in a large US representative sample of high school students; N = 81,000) in predicting educational attainment, annual income, and occupational prestige eleven years later. Specifically, we tested whether individual differences followed one of three patterns in relation to parental SES when predicting attained status: (a) the independent effects hypothesis (i.e., individual differences predict attainments independent of parental SES level), (b) the resource substitution hypothesis (i.e., individual differences are stronger predictors of attainments at lower levels of parental SES), and (c) the Matthew effect hypothesis (i.e., “the rich get richer,” individual differences are stronger predictors of attainments at higher levels of parental SES). We found that personality traits and intelligence in adolescence predicted later attained status above and beyond parental SES. A standard deviation increase in individual differences translated to up to 8 additional months of education, $4,233 annually, and more prestigious occupations. Furthermore, although we did find some evidence for both the resource substitution and the Matthew effect hypotheses, the most robust pattern across all models supported the independent effects hypothesis. Intelligence was the exception, where interaction models were more robust. Finally, we found that although personality traits may help compensate for background disadvantage to a small extent, they do not usually lead to a “full catch up” effect, unlike intelligence. This was the first longitudinal study of status attainment to test interactive models of individual differences and background factors. PMID:25402679
Rader, T; Fastl, H; Baumann, U
2017-03-01
After implantation of cochlear implants with hearing preservation for combined electronic acoustic stimulation (EAS), the residual acoustic hearing ability relays fundamental speech frequency information in the low frequency range. With the help of acoustic simulation of EAS hearing perception the impact of frequency and level fine structure of speech signals can be systematically examined. The aim of this study was to measure the speech reception threshold (SRT) under various noise conditions with acoustic EAS simulation by variation of the frequency and level information of the fundamental frequency f0 of speech. The study was carried out to determine to what extent the SRT is impaired by modification of the f0 fine structure. Using partial tone time pattern analysis an acoustic EAS simulation of the speech material from the Oldenburg sentence test (OLSA) was generated. In addition, determination of the f0 curve of the speech material was conducted. Subsequently, either the parameter frequency or level of f0 was fixed in order to remove one of the two fine contour information of the speech signal. The processed OLSA sentences were used to determine the SRT in background noise under various test conditions. The conditions "f0 fixed frequency" and "f0 fixed level" were tested under two different situations, under "amplitude modulated background noise" and "continuous background noise" conditions. A total of 24 subjects with normal hearing participated in the study. The SRT in background noise for the condition "f0 fixed frequency" was more favorable in continuous noise with 2.7 dB and in modulated noise with 0.8 dB compared to the condition "f0 fixed level" with 3.7 dB and 2.9 dB, respectively. In the simulation of speech perception with cochlear implants and acoustic components, the level information of the fundamental frequency had a stronger impact on speech intelligibility than the frequency information. The method of simulation of transmission of cochlear implants allows investigation of how various parameters influence speech intelligibility in subjects with normal hearing.
Roberts, Chris; Zoanetti, Nathan; Rothnie, Imogene
2009-04-01
The multiple mini-interview (MMI) was initially designed to test non-cognitive characteristics related to professionalism in entry-level students. However, it may be testing cognitive reasoning skills. Candidates to medical and dental schools come from diverse backgrounds and it is important for the validity and fairness of the MMI that these background factors do not impact on their scores. A suite of advanced psychometric techniques drawn from item response theory (IRT) was used to validate an MMI question bank in order to establish the conceptual equivalence of the questions. Bias against candidate subgroups of equal ability was investigated using differential item functioning (DIF) analysis. All 39 questions had a good fit to the IRT model. Of the 195 checklist items, none were found to have significant DIF after visual inspection of expected score curves, consideration of the number of applicants per category, and evaluation of the magnitude of the DIF parameter estimates. The question bank contains items that have been studied carefully in terms of model fit and DIF. Questions appear to measure a cognitive unidimensional construct, 'entry-level reasoning skills in professionalism', as suggested by goodness-of-fit statistics. The lack of items exhibiting DIF is encouraging in a contemporary high-stakes admission setting where candidates of diverse personal, cultural and academic backgrounds are assessed by common means. This IRT approach has potential to provide assessment designers with a quality control procedure that extends to the level of checklist items.
NASA Astrophysics Data System (ADS)
Dickie, H.; Colwell, K.
2013-12-01
In today's post-nuclear age, there are many man-made sources of radioactivity, in addition to the natural background we expect from cosmic and terrestrial origins. While all atoms possess unstable isotopes, there are few that are abundant enough, energetic enough, and have long enough half-lives to pose a signicant risk of ionizing radiation exposure. We hypothesize a decreasing relative radiation measurement (in detected counts per minute [CPM]) at nine locations that might pose occupational or environmental hazard: 1. A supermarket produce aisle (living tissue has high concentration of 40K) 2. A hospital (medical imaging uses X-rays and radioactive dyes) 3. The electronics section of a superstore (high voltage electronics have the potential to produce ionizing radiation) 4. An electrical transformer (similar reasons) 5. An antique store (some ceramics and glazes use radioisotopes that are now outlawed) 6. A gasoline pump (processing and terrestrial isotope contamination might leave a radioactive residue) 7. A fertilized eld (phosphate rock contains uranium and thorium, in addition to potassium) 8. A house (hopefully mild background, but potential radon contamination) 9. A school (should be radiologically neutral) We tested the hypothesis by measuring 100 minutes of counts on a self-assembled MightyOhmTM Geiger counter at each location. Our results show that contrary to the hypothesized ordering, the house was the most radiologically active. We present possible explanations for the observed radiation levels, as well as possible sources of measurement error, possible consequences of prolonged exposure to the measured levels, and suggestions for decreasing exposure and environmental impact.
Annual INTEC Groundwater Monitoring Report for Group 5 - Snake River Plain Aquifer (2001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roddy, Michael Scott
2002-02-01
This report describes the monitoring activities conducted and presents the results of groundwater sampling and water-level measurements from October 2000 to September 2001. Groundwater samples were initially collected from 41 wells from the Idaho Nuclear Technology and Engineering Center and the Central Facilities Area and analyzed for iodine-129, strontium-90, tritium, gross alpha, gross beta, technetium-99, uranium isotopes, plutonium isotopes, neptunium-237, americium-241, gamma spectrometry, and mercury. Samples from 41 wells were collected in April and May 2001. Additional sampling was conducted in August 2001 and included the two CFA production wells, the CFA point of compliance for the production wells, onemore » well that was previously sampled and five additional monitoring wells. Iodine-129 and strontium-90 were the only analytes above their respective maximum contaminant levels. Iodine-129 was detected just above its maximum contaminant level of 1 pCi/L at two of the Central Facilities Area landfill wells. Iodine-129 was detected in the CFA production wells at 0.35±0.083 pCi/L in CFA-1, but was below detectable activity in CFA-2. Strontium-90 was above its maximum contaminant level of 8 pCi/L in several wells near the Idaho Nuclear Technology and Engineering Center but was below its maximum contaminant level in the downgradient wells at the Central Facilities Area landfills. Sr-90 was not detected in the CFA production wells. Gross beta results generally mirrored the results for strontium-90 and technetium-99. Plutonium isotopes and neptunium-237 were not detected. Uranium-233/234 and uranium-238 isotopes were detected in all samples. Concentrations of background and site wells were similar and are within background limits for total uranium determined by the USGS, suggesting that the concentrations are background. Uranium-235/236 was detected in 11 samples, but all the detected concentrations were similar and near the minimum detectable activity. Americium-241 was detected at three locations near the minimum detectable activity of approximately 0.07 pCi/L. The gamma spectrometry results detected cesium-137 in three samples, potassium-40 at eight locations, and radium-226 at one location. Mercury was below its maximum contaminant level of 2 µg/L in all samples. Gamma spectrometry results for the CFA production wells did not detect any analytes. Water-level measurements were taken from wells in the Idaho Nuclear Technology and Engineering Center, Central Facilities Area, and the area south of Central Facilities Area to evaluate groundwater flow directions. Water-level measurements indicated groundwater flow to the south-southwest from the Idaho Nuclear Technology and Engineering Center.« less
ERIC Educational Resources Information Center
Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie
2017-01-01
Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…
Leijs, Marike M; Koppe, Janna G; Vulsma, Thomas; Olie, Kees; van Aalderen, Wim M C; de Voogt, Pim; Legler, Juliette; Ten Tusscher, Gavin W
2017-01-01
Dioxins and PCBs are highly toxic and persistent environmental pollutants that are measurable in humans worldwide. These persistent organic pollutants are associated with a higher incidence of diabetes mellitus. We hypothesise that perinatal (background) exposure to industrial pollutants like dioxins also influences body mass development and energy metabolism in later life. In The Netherlands, the perinatal exposure (prenatal exposure and postnatal lactational intake) to dioxins has been studied prospectively since 1987. Fasting glucose, insulin, HbA1c and leptin were analysed in 33 children of the original cohort of 60. BMI, glucose:insulin and BMI:leptin ratios were calculated. Prenatal exposure, lactational intake and current serum levels of dioxins (PCDD/F), dl-PCBs and PBDE concentrations were determined using (HR)GC-MS. Prenatal dioxin (PCDD/F) exposure was positively correlated to the glucose:insulin ratio (p = 0.024) and negatively correlated to the fasting insulin concentration (p = 0.017) in adolescence. Postnatal lactational PCDD/F intake was also negatively correlated to fasting insulin concentration (p = 0.028). Current serum levels of PCDD/Fs and total TEQ (dl-PCBs+PCDD/Fs) were positively correlated to the fasting serum glucose concentration (p = 0.015 and p = 0.037, respectively).No metabolic effects were seen in association with current serum levels of PBDEs. A positive correlation between the insulin and leptin concentrations (p = 0.034) was observed. No effects were found on leptin levels, BMI:leptin ratio, HbA1c levels or BMI. This study indicates that prenatal and lactational exposure influences glucose metabolism in adolescents, presumably through a negative effect on insulin secretion by pancreatic beta cells. Additionally, the very low recent background exposure to dioxins in puberty possibly has an effect on the glucose level.
Benchmarking shielding simulations for an accelerator-driven spallation neutron source
Cherkashyna, Nataliia; Di Julio, Douglas D.; Panzner, Tobias; ...
2015-08-09
The shielding at an accelerator-driven spallation neutron facility plays a critical role in the performance of the neutron scattering instruments, the overall safety, and the total cost of the facility. Accurate simulation of shielding components is thus key for the design of upcoming facilities, such as the European Spallation Source (ESS), currently in construction in Lund, Sweden. In this paper, we present a comparative study between the measured and the simulated neutron background at the Swiss Spallation Neutron Source (SINQ), at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The measurements were carried out at several positions along the SINQ monolithmore » wall with the neutron dosimeter WENDI-2, which has a well-characterized response up to 5 GeV. The simulations were performed using the Monte-Carlo radiation transport code Geant4, and include a complete transport from the proton beam to the measurement locations in a single calculation. An agreement between measurements and simulations is about a factor of 2 for the points where the measured radiation dose is above the background level, which is a satisfactory result for such simulations spanning many energy regimes, different physics processes and transport through several meters of shielding materials. The neutrons contributing to the radiation field emanating from the monolith were confirmed to originate from neutrons with energies above 1 MeV in the target region. The current work validates Geant4 as being well suited for deep-shielding calculations at accelerator-based spallation sources. We also extrapolate what the simulated flux levels might imply for short (several tens of meters) instruments at ESS.« less
Analysis of Trace Siderophile Elements at High Spatial Resolution Using Laser Ablation ICP-MS
NASA Astrophysics Data System (ADS)
Campbell, A. J.; Humayun, M.
2006-05-01
Laser ablation inductively coupled plasma mass spectometry is an increasingly important method of performing spatially resolved trace element analyses. Over the last several years we have applied this technique to measure siderophile element distributions at the ppm level in a variety of natural and synthetic samples, especially metallic phases in meteorites and experimental run products intended for trace element partitioning studies. These samples frequently require trace element analyses to be made at a finer spatial resolution (25 microns or better) than is frequently attained using LA-ICP-MS. In this presentation we review analytical protocols that were developed to optimize the LA-ICP-MS measurements for high spatial resolution. Particular attention is paid to the trade-offs involving sensitivity, ablation pit depth and diameter, background levels, and number of elements measured. To maximize signal/background ratios and avoid difficulties associated with ablating to depths greater than the ablation pit diameter, measurement involved integration of rapidly varying, transient but well-behaved signals. The abundances of platinum group elements and other siderophile elements in ferrous metals were calibrated against well-characterized standards, including iron meteorites and NIST certified steels. The calibrations can be set against the known abundance of an independently determined element, but normalization to 100 percent can also be employed, and was more useful in many circumstances. Evaluation of uncertainties incorporated counting statistics as well as a measure of instrumental uncertainty, determined by replicate analyses of the standards. These methods have led to a number of insights into the formation and chemical processing of metal in the early solar system.
ERIC Educational Resources Information Center
Hudson, Sophie; Levickis, Penny; Down, Kate; Nicholls, Ruth; Wake, Melissa
2015-01-01
Background: Maternal responsiveness has been shown to predict child language outcomes in clinical samples of children with language delay and non-representative samples of typically developing children. An effective and timely measure of maternal responsiveness for use at the population level has not yet been established. Aims: To determine…
ERIC Educational Resources Information Center
West, Lloyd Wilbert
An investigation was designed to ascertain the effects of cultural background on selected intelligence tests and to identify instruments which validly measure intellectual ability with a minimum of cultural bias. A battery of tests, selected for factor analytic study, was administered and replicated at four grade levels to a sample of Metis and…
ERIC Educational Resources Information Center
Miniscalco, Carmela; Rudling, Maja; Råstam, Maria; Gillberg, Christopher; Johnels, Jakob Åsberg
2014-01-01
Background: Research in the last decades has clearly pointed to the important role of language and communicative level when trying to understand developmental trajectories in children with autism spectrum disorders (ASD). Aims: The purpose of this longitudinal study was to investigate whether (1) "core language skills", measured as…
Test of the electric charge conservation law with Borexino detector
NASA Astrophysics Data System (ADS)
Vishneva, A.; Agostini, M.; Appel, S.; Bellini, G.; Benziger, J.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Cavalcante, P.; Chepurnov, A.; D' Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Etenko, A.; Fomenko, K.; Franco, D.; Gabriele, F.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jedrzejczak, K.; Kaiser, M.; Kobychev, V.; Korablev, D.; Korga, G.; Kryn, D.; Laubenstein, M.; Lehnert, B.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Pallavicini, M.; Papp, L.; Perasso, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, N.; Schonert, S.; Semenov, D.; Simgen, H.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.
2016-02-01
The new limit on the electron lifetime is obtained from data of the Borexino experiment. The expected signal from the e → γν decay mode is a 256 keV photon detected in liquid scintillator. Because of the extremely low radioactive background level in the Borexino detector it was possible to improve the previous measurement by two orders of magnitude.
ERIC Educational Resources Information Center
Freeman, Richard B.; Machin, Stephen J.; Viarengo, Martina G.
2010-01-01
The motivation for this paper is to increase individuals' understanding of the way in which inequality in educational outcomes and in the relation between measures of backgrounds is related to levels and dispersion of educational performance of young persons. The article thus sheds light on the international variation in the importance of…
Dreams and Opportunities: Immigrant Families and Iowa's Future. Iowa Kid's Count Special Report
ERIC Educational Resources Information Center
Wright, Michelle Stover
2010-01-01
The fact that there has been population growth in Iowa at all (about 100,000 growth per decade over the last 50 years) is due in large measure to an increased level of immigration into the state. This immigration has helped to stabilize Iowa's population and workforce. Immigrants bring diverse experiences and backgrounds with them. This report…
ERIC Educational Resources Information Center
Riches, Vivienne C.; Parmenter, Trevor R.; Llewellyn, Gwynnyth; Hindmarsh, Gabrielle; Chan, Jeff
2009-01-01
Background: There is an urgent need for developing reliable, valid and practical instruments that assess and classify the support needed by persons with disability to function in their chosen living, working and social environments. I-CAN is an instrument that addresses the frequency and level of support needed (not individual skills or deficits)…
Facial Expression of Affect in Children with Cornelia de Lange Syndrome
ERIC Educational Resources Information Center
Collis, L.; Moss, J.; Jutley, J.; Cornish, K.; Oliver, C.
2008-01-01
Background: Individuals with Cornelia de Lange syndrome (CdLS) have been reported to show comparatively high levels of flat and negative affect but there have been no empirical evaluations. In this study, we use an objective measure of facial expression to compare affect in CdLS with that seen in Cri du Chat syndrome (CDC) and a group of…
Analysis of nuclear resonance fluorescence excitation measured with LaBr3(Ce) detectors near 2 MeV
NASA Astrophysics Data System (ADS)
Omer, Mohamed; Negm, Hani; Ohgaki, Hideaki; Daito, Izuru; Hayakawa, Takehito; Bakr, Mahmoud; Zen, Heishun; Hori, Toshitada; Kii, Toshiteru; Masuda, Kai; Hajima, Ryoichi; Shizuma, Toshiyuki; Toyokawa, Hiroyuki; Kikuzawa, Nobuhiro
2013-11-01
The performance of LaBr3(Ce) to measure nuclear resonance fluorescence (NRF) excitations is discussed in terms of limits of detection and in comparison with high-purity germanium (HPGe) detectors near the 2 MeV region where many NRF excitation levels from special nuclear materials are located. The NRF experiment was performed at the High Intensity γ-ray Source (HIγS) facility. The incident γ-rays, of 2.12 MeV energy, hit a B4C target to excite the 11B nuclei to the first excitation level. The statistical-sensitive non-linear peak clipping (SNIP) algorithm was implemented to eliminate the background and enhance the limits of detection for the spectra measured with LaBr3(Ce). Both detection and determination limits were deduced from the experimental data.
Retrospective determination of the contamination in the HML's counting chambers.
Kramer, Gary H; Hauck, Barry; Capello, Kevin; Phan, Quoc
2008-09-01
The original documentation surrounding the purchase of the Human Monitoring Laboratory's (HML) counting chambers clearly showed that the steel contained low levels of radioactivity, presumably as a result of A-bomb fallout or perhaps to the inadvertent mixing of radioactive sources with scrap steel. Monte Carlo simulations have been combined with experimental measurements to estimate the level of contamination in the steel of the HML's whole body counting chamber. A 24-h empty chamber background count showed the presence of 137Cs and 60Co. The estimated activity of 137Cs in the 51 tons of steel was 2.7 kBq in 2007 (51.3 microBq g(-1) steel) which would have been 8 kBq at the time of manufacture. The 60Co that was found in the background spectrum is postulated to be contained in the bed-frame. The estimated amount in 2007 was 5 Bq and its origin is likely to be contaminated scrap metal entering the steel production cycle sometime in the past. The estimated activities are 10 to 25 times higher than the estimated minimum detectable activity for this measurement. These amounts have no impact on the usefulness of the whole body counter.
Measuring double-electron capture with liquid xenon experiments
NASA Astrophysics Data System (ADS)
Mei, D.-M.; Marshall, I.; Wei, W.-Z.; Zhang, C.
2014-01-01
We investigate the possibilities of observing the decay mode for 124Xe in which two electrons are captured, two neutrinos are emitted, and the final daughter nucleus is in its ground state, using dark matter experiments with liquid xenon. The first upper limit of the decay half-life is calculated to be 1.66 × 1021 years at a 90% confidence level (C.L.) obtained with the published background data from the XENON100 experiment. Employing a known background model from the large underground xenon (LUX) experiment, we predict that the detection of double-electron capture of 124Xe to the ground state of 124Te with LUX will have approximately 115 events, assuming a half-life of 2.9 × 1021 years. We conclude that measuring 124Xe 2ν double-electron capture to the ground state of 124Te can be performed more precisely with the proposed LUX-Zeplin (LZ) experiment.