Rocchetti, Andrea; Di Matteo, Luigi; Bottino, Paolo; Foret, Benjamin; Gamalero, Elisa; Calabresi, Alessandra; Guido, Gianluca; Casagranda, Ivo
2016-11-01
The performance of 3 blood culture bottles (BACTEC Plus Aerobic/F, Plus Anaerobic/F, and Anaerobic Lytic/F) were analyzed with clinical specimens collected from 688 Emergency Department patients. A total of 270 strains belonging to 33 species were identified, with E. coli and S. aureus as the most frequently detected. Overall recovery rate (RR) of bacteria and yeast was equivalent in the Plus Aerobic/F vials (208 of 270 isolates; 77.0%) and Anaerobic Lytic/F vials (206 isolates; 76.3%) and significantly better than in the Plus Anaerobic/F vials (189 isolates; 70.0%). Median time to detection (TTD) was earliest with the Anaerobic Lytic/F vials (12.0h) compared with the Plus Aerobic/F (14.6h) and Plus Anaerobic/F vials (15.4h). Positivity rate (PR) was similar for Anaerobic Lytic/F vials (76.9%) and Plus Aerobic/F vials (76.5%), but better if compared with Plus Anaerobic/F vials (69.4%). The PR and TTD for the combination of Plus Aerobic/F with Anaerobic Lytic/F (94.5% and 12.3h, respectively) was significantly better than with Plus Aerobic/F with Plus Anaerobic/F (87.8% and 14.1h). Copyright © 2016 Elsevier B.V. All rights reserved.
Sagi, Moshe; Nesher, Lior; Yagupsky, Pablo
2017-03-01
The performance of the Bactec FX blood culture system for detecting Brucella bacteremia within the routine 1-week incubation period was assessed in a prospective study conducted in an area in southern Israel in which Brucella melitensis is endemic. Aerobic vials (BD Bactec Plus Aerobic/F medium) inoculated with blood specimens obtained from adult patients with positive Rose-Bengal screening test results were monitored for 4 consecutive weeks, and blind subcultures of negative vials were performed on solid media on days 7 and 28. During a 16-month period, a total of 31 (35.2%) of 88 cultures, obtained from 19 (38.0%) of 50 patients, were positive for Brucella melitensis The blood culture instrument identified 30 (96.8%) of 31 positive vials within 7 days of incubation; the single positive vial that was missed by the automated readings was detected only by the blind subculture performed on day 28. It is concluded that the Bactec FX system is able to detect the vast majority of episodes of Brucella bacteremia within the 1-week incubation protocol instituted in most clinical microbiology laboratories and without the need to perform blind subcultures of negative vials, enabling early diagnosis and saving labor and incubation time and space. Copyright © 2017 American Society for Microbiology.
Araj, G F; Talhouk, R S; Itani, L Y; Jaber, W; Jamaleddine, G W
2000-09-01
American University of Beirut Medical Center, Lebanon. To assess the performance of a polymerase chain reaction (PCR) using primers that flank 542 bp within IS6110 in Mycobacterium tuberculosis (TB) vs. microscopy and BACTEC culture, in the diagnosis of tuberculosis. A total of 82 clinical respiratory pulmonary specimens and 73 samples from BACTEC vials were tested by the three methods. Of 24 smear-positive culture-positive (SP-CP) and 11 smear-negative culture-positive (SN-CP) TB specimens, PCR detected 83% and 64%, respectively. Among 17 specimens yielding mycobacteria other than tuberculosis (MOTT), the PCR was positive in 33% SP-CP and 14% SN-CP specimens. Among the 73 BACTEC vials, PCR was positive in 36 of 38 (95%) yielding culture-positive TB, and in one of 20 (5%) yielding culture positive MOTT. None of the 30 smear-negative culture-negative (SN-CN) clinical specimens and 15 of the CN vials were positive by PCR. The overall sensitivity of PCR was 77% and 95% for TB detection in respiratory specimens and BACTEC vials, respectively, and the specificity was 94% in both. Because a substantial number of TB cases are missed, especially in SN-CP specimens, a PCR-based assay utilizing these primers cannot be used reliably, alone, in clinical laboratory diagnosis of mycobacterial respiratory infections.
Kaasch, Achim J.; Soriano, Alex; Torres, Jorge-Luis; Vergara, Andrea; Morata, Laura; Zboromyrska, Yuliya; De La Calle, Cristina; Alejo, Izaskun; Hernández, Cristina; Cardozo, Celia; Marco, Franscesc; Del Río, Ana; Almela, Manel; Mensa, Josep; Martínez, José Antonio
2014-01-01
This study shows the accuracy of exclusive or earlier growth in anaerobic vials to predict Candida glabrata in a large series of candidemic patients from two European hospitals using the Bactec 9240 system. Alternatively, C. glabrata can be predicted by a time to positivity cutoff value, which should be determined for each setting. PMID:24899027
Cobos-Trigueros, Nazaret; Kaasch, Achim J; Soriano, Alex; Torres, Jorge-Luis; Vergara, Andrea; Morata, Laura; Zboromyrska, Yuliya; De La Calle, Cristina; Alejo, Izaskun; Hernández, Cristina; Cardozo, Celia; Marco, Franscesc; Del Río, Ana; Almela, Manel; Mensa, Josep; Martínez, José Antonio
2014-08-01
This study shows the accuracy of exclusive or earlier growth in anaerobic vials to predict Candida glabrata in a large series of candidemic patients from two European hospitals using the Bactec 9240 system. Alternatively, C. glabrata can be predicted by a time to positivity cutoff value, which should be determined for each setting. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Hines, Nichole; Payeur, Janet B; Hoffman, Lorraine J
2006-05-01
The BACTEC Microbacteria Growth Indicator Tube (MGIT) 960 system was evaluated to determine how it compares with the BACTEC 460 radiometric system and solid media for recovery of Mycobacterium bovis from tissue samples. A total of 506 bovine lymph node samples were collected from abattoirs in the United States and Mexico between November 2003 and September 2004. Processed samples were inoculated into an MGIT 960 tube, BACTEC 460 vial, and Middlebrook 7H10 and Middlebrook 7H11 solid media. Ziehl-Neelsen slides were prepared to check for contaminants and confirm the presence of acid-fast positive bacilli. Samples containing acid-fast bacilli were confirmed as members of the Mycobacterium tuberculosis complex by a nucleic acid assay. Niacin and nitrate biochemical tests were used to distinguish M. bovis from M. tuberculosis isolates. Statistical analyses were performed to compare recovery rate, mean time to detection, contamination rates, as well as pair-wise comparisons in each category. The results showed that the MGIT 960 system had a higher recovery rate of M. bovis (122/129) than did the BACTEC 460 (102/129) and solid media system (96/129). The average time to detection was 15.8 days for the MGIT 960 system, 28.2 days for the BACTEC 460 system, and 43.4 days for solid media. Contamination rates were 6.9% for the MGIT 960 system, 3.4% for the BACTEC 460 system, and 21.7% for solid media. These results indicate the MGIT 960 system can be used as an alternative to the BACTEC 460 system for recovering M. bovis from tissue samples.
Daxboeck, Florian; Dornbusch, Hans Jürgen; Krause, Robert; Assadian, Ojan; Wenisch, Christoph
2004-01-01
A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms.
Whittington, Ann-Michele; Waldron, Anna; Begg, Douglas J.; de Silva, Kumi; Purdie, Auriol C.; Plain, Karren M.
2013-01-01
Liquid culture of Mycobacterium avium subsp. paratuberculosis from clinical samples, such as feces, is the most sensitive antemortem test for the diagnosis of Johne's disease in ruminants. In Australia, New Zealand, the United States, and some other countries, the Bactec 460 system with modified Bactec 12B medium (Becton, Dickinson) has been the most commonly used liquid culture system, but it was discontinued in 2012. In this study, a new liquid culture medium, M7H9C, was developed. It consists of a Middlebrook 7H9 medium base with added Casitone, albumin, dextrose, catalase, egg yolk, mycobactin J, and a cocktail of antibiotics. We found that polyoxyethylene stearate (POES) was not essential for the cultivation of M. avium subsp. paratuberculosis in either the Bactec 12B or the M7H9C medium. The limit of detection determined using pure cultures of the C and S strains of M. avium subsp. paratuberculosis was 7 bacilli per 50 μl inoculum in the two media. The new medium was validated using 784 fecal and tissue samples from sheep and cattle, >25% of which contained viable M. avium subsp. paratuberculosis. Discrepant results for the clinical samples between the two media were mostly associated with samples that contained <10 viable bacilli per gram, but these results were relatively uncommon, and the performances of the two media were not significantly different. M7H9C medium was less than half the cost of the Bactec 12B medium and did not require regular examination during incubation, but a confirmatory IS900 PCR test had to be performed on every culture after the predetermined incubation period. PMID:24048541
Moore, T D; Horton, R; Utrup, L J; Miller, L A; Poupard, J A
1996-01-01
The stabilities of amoxicillin (16 micrograms/ml) and clavulanate (8 micrograms/ml), alone and in combination in BACTEC medium (Middlebrook 7H12B medium), were determined by high-performance liquid chromatography (HPLC) and bioassay. By HPLC, the half-life of amoxicillin (trihydrate and sodium) in combination with clavulanate in nonradiolabelled 7H12B medium was 6.7 days, whereas the half-life of clavulanate in combination with amoxicillin was 2.0 days. By bioassay, the half-lives of amoxicillin trihydrate and clavulanate in radiolabelled 7H12B medium were comparable (7 and 2 days, respectively) to those determined by HPLC. When clavulanate was tested alone, the half-life was determined to be 1.88 days by HPLC and 1.87 days by bioassay. The relatively short half-life of clavulanate can be adjusted by a procedure of "topping up," or adding one-half the concentration of clavulanate every second day, in order to allow accurate amoxicillin-clavulanate MIC testing with the BACTEC mycobacterial susceptibility system. PMID:8727931
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brannon, P.; Kiehn, T.E.
1985-12-01
The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours and Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, weremore » detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures.« less
Bradner, L; Robbe-Austerman, S; Beitz, D C; Stabel, J R
2013-07-01
Mycobacterium avium subsp. paratuberculosis is shed into the milk and feces of cows with advanced Johne's disease, allowing the transmission of M. avium subsp. paratuberculosis between animals. The objective of this study was to formulate an optimized protocol for the isolation of M. avium subsp. paratuberculosis in milk. The parameters investigated included chemical decontamination with N-acetyl-l-cysteine-sodium hydroxide (NALC-NaOH), alone and in combination with antibiotics (vancomycin, amphotericin B, and nalidixic acid), and the efficacy of solid (Herrold's egg yolk medium [HEY]) and liquid (Bactec 12B and para-JEM) culture media. For each experiment, raw milk samples from a known noninfected cow were inoculated with 10(2) to 10(8) CFU/ml of live M. avium subsp. paratuberculosis organisms. The results indicate that an increased length of exposure to NALC-NaOH from 5 to 30 min and an increased concentration of NaOH from 0.5 to 2.0% did not affect the viability of M. avium subsp. paratuberculosis. Additional treatment of milk samples with the antibiotics following NALC-NaOH treatment decreased the recovery of viable M. avium subsp. paratuberculosis cells more than treatment with NALC-NaOH alone. The Bactec 12B medium was the superior medium of the three evaluated for the isolation of M. avium subsp. paratuberculosis from milk, as it achieved the lowest threshold of detection. The optimal conditions for NALC-NaOH decontamination were determined to be exposure to 1.50% NaOH for 15 min followed by culture in Bactec 12B medium. This study demonstrates that chemical decontamination with NALC-NaOH resulted in a greater recovery of viable M. avium subsp. paratuberculosis cells from milk than from samples treated with hexadecylpyridinium chloride (HPC). Therefore, it is important to optimize milk decontamination protocols to ensure that low concentrations of M. avium subsp. paratuberculosis can be detected.
Camposampiero, D; Grandesso, S; Zanetti, E; Mazzucato, S; Solinas, M; Parekh, M; Frigo, A C; Gion, M; Ponzin, D
2013-01-01
Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were performed (a) after six days of storage, (b) end of storage, and (c) after 24 hours of preservation in deturgescent liquid sequentially. 10,655 storage and deturgescent media samples were subjected to microbiological control using BACTEC (6-day incubation) and HB&L (24-hour incubation) systems simultaneously. BACTEC positive/negative refers to both/either aerobic and anaerobic positives/negatives, whereas HB&L can only detect the aerobic microbes, and therefore the positives/negatives depend on the presence/absence of aerobic microorganisms. Results. 147 (1.38%) samples were identified positive with at least one of the two methods. 127 samples (134 identified microorganisms) were positive with both HB&L and BACTEC. 14 HB&L+/BACTEC- and 6 BACTEC+/HB&L- were identified. Sensitivity (95.5%), specificity (99.8%), and positive (90.1%) and negative predictive values (99.9%) were high with HB&L considering a 3.5% annual contamination rate. Conclusion. HB&L is a rapid system for detecting microorganisms in corneal storage medium in addition to the existing methods.
78 FR 4446 - Exempt Chemical Preparations Under the Controlled Substances Act
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-22
... Laboratories Liquichek Immunoassay Plus Amber Vial: 10 mL; Box: 12/22/2011 Control Levels 1, 2, and 3. 12 vials. Bio-Rad Laboratories Liquichek Immunoassay Plus Amber Vial: 10 mL; Box: 12/22/2011 Control Trilevel. 12 vials. Bio-Rad Laboratories Liquichek Immunoassay Plus Amber Vial: 5 mL; Box: 3 12/22/2011 Control...
Whittington, Richard J
2009-03-01
Culture of Mycobacterium avium subsp. paratuberculosis is the definitive diagnostic test for Johne's disease, a chronic granulomatous enteropathy of animals. Compared to solid media, the identification of all strains of the organism in liquid media can be more difficult because the appearance of colonies and mycobactin dependence are not observable, and the growth of other organisms needs to be distinguished, commonly by PCR. Factors affecting the isolation rate of S strains and the contamination rate in modified Middlebrook 7H9 broth (Bactec 12B) and 7H10 agar were studied using 11,598 fecal samples and 2,577 tissue samples from sheep from 1,421 farms over 10 years. Minimization of contamination in Bactec cultures required the avoidance of the carryover of fecal particles from the first sedimentation step in the double-incubation centrifugation method, and contamination was reduced significantly by incubating the sample in a solution containing vancomycin, amphotericin B, and nalidixic acid for 3 days compared to 2 days. The growth of irrelevant microorganisms confounded the identification of M. avium subsp. paratuberculosis in liquid culture by inhibiting IS900 PCR and in solid medium culture by inhibiting the growth of M. avium subsp. paratuberculosis or obscuring colonies. The contamination of samples was clustered in certain laboratory submissions and was reduced by including ampicillin in Bactec medium without affecting the odds of isolation of M. avium subsp. paratuberculosis. The long-term contamination rate for fecal cultures was about 7%, and that for tissue cultures was <0.2%. Liquid medium was more sensitive than solid medium culture for M. avium subsp. paratuberculosis. The applicability of these findings for C strains is discussed.
Detection of bacterial growth by gas absorption.
Waters, J R
1992-05-01
When 24 different aerobic organisms were grown in a shaken culture, all were found to first absorb gas from the headspace. In a rudimentary medium, such as tryptic soy broth, 16 of the 24 organisms did not produce gas following the initial gas absorption. We have developed a simple, noninvasive method for detecting both gas absorption and production in multiple culture vials. The time to positivity was compared with that obtained by the BACTEC 460 blood culture system. For nearly all of these organisms, there was no difference. For some of those organisms that did not produce gas, e.g. Staphylococcus epidermidis, Moraxella osloensis, and Neisseria meningitidis, detection by gas absorption was a few hours faster. Gas absorption appears to be a promising technique for a new automated blood culture system because of its simplicity and because medium without special additives can be used to detect organisms that do not produce gas.
Surase, P V; Nataraj, G; Pattamadai, K; Mehta, P R; Pazare, A R; Agarwal, M C; Nanavati, R N
2016-01-01
Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. A prospective study was carried out in a multispecialty tertiary care teaching hospital. A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.
Production of UC-labeled gas in BACTEC Neisseria Differentiation kits by Neisseria cinerea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyce, J.M.; Mitchell, E.B. Jr.; Knapp, J.S.
1985-09-01
Six strains of Neisseria cinerea were tested in BACTEC Neisseria Differentiation kits (Johnston Laboratories, Inc., Towson, Md.), and all yielded positive glucose growth indices and negative maltose and fructose growth indices. These results were similar to those achieved with Neisseria gonorrhoeae. However, most of the N. cinerea isolates tested yielded 3-h glucose growth indices that were lower than those obtained with gonococci. UC-labeled gas was produced significantly faster by N. gonorrhoeae than by N. cinerea. Additional studies suggested that the UC-labeled gas produced by N. cinerea was carbon dioxide. N. cinerea strains were similar to Branhamella catarrhalis strains because bothmore » species failed to produce detectable acid from glucose, maltose, sucrose, fructose, and lactose in cysteine-tryptic agar media. However, in contrast to N. cinerea strains, B. catarrhalis strains did not metabolize glucose in BACTEC Neisseria Differentiation kits.« less
2011-09-01
carbon produced from TiC (From [10]). .................................... 27 Figure 9. LiFePO4 , acetylene black, and PVDF powders in weighing boat...dispenser, and the ball milled powder mixture x containing LiFePO4 , acetylene black, and PVDF binder; and b) Prepared slurry after adding NMP solvent to...the powder mixture. ..... 39 Figure 12. Sample vial containing a LiFePO4 slurry inside the ultrasonic bath. Each vial was sonicated for 30 minutes
Itani, Lina Y; Cherry, Mohamad A; Araj, George F
2005-01-01
Rapid detection of Mycobacterium tuberculosis (MTB), especially multidrug-resistant strains, is of importance for prompt clinical management and initiation of public health control measures. Culture remains the "gold" standard in the confirmatory laboratory diagnosis of mycobacterial infections. The reliability of the automated radiometric BACTEC 460 TB (BACTEC) system for the rapid detection of mycobacteria in clinical specimens was evaluated and compared to the conventional culture on Lowenstein-Jensen (LJ) medium. All clinical specimens submitted for mycobacterial culture were processed and simultaneously cultured on both BACTEC broth medium and LJ solid medium. Acid-fast bacilli (AFB) smears were also performed on the sediments. Differentiation of mycobacterial isolates as MTB or Mycobacterium sp. other than tuberculosis (MOTT) was based on the BACTEC NAP test. All positive culture findings recovered between January 1997 and December 2003 were analyzed in this study. A total of 3300 specimens were tested of which 355 (10.7%) yielded positive cultures consisting of 233 (65.6%) MTB and 122 (34.4%) MOTT. The percentages of AFB smear-positive were 45% and 49% in clinical specimens yielding MTB & MOTT, respectively. Though several types of specimens were cultured, most isolates (72% of MTB & 91% of MOTT) were recovered from respiratory specimens. Overall, the BACTEC showed significantly higher mycobacteria recovery rate (91%) than LJ (77%). In terms of times to detection, BACTEC showed significantly shorter detection time of isolates than LJ for the overall (mean 9.6 days for BACTEC vs. 22.8 days for LJ) and for each category of AFB smear finding. The detection time is shortened for BACTEC with the increasing grade of smear positivity. BACTEC is substantially more sensitive, efficient and rapid than LJ in the laboratory diagnosis of mycobacterial infections. This system also provides rapid differentiation of MTB from MOTT and susceptibility test results on MTB. However, the simultaneous use of BACTEC and LJ is recommended to provide maximum optimal recovery of isolates from clinical specimens. The time-saving in BACTEC provides an excellent facility for physicians in patient management and to public health personnel for prompt initiation of infection control measures.
In vitro anti-mycobacterial activities of three species of Cola plant extracts (Sterculiaceae).
Adeniyi, B A; Groves, M J; Gangadharam, P R J
2004-05-01
Extracts obtained from three Nigerian Sterculiaceae plants: Cola accuminata, C. nitida and C. milleni were screened for anti-mycobacterium properties using a slow growing Mycobacterium bovis ATCC 35738 (designated BCG Mexican and known to have some virulence in mouse and guinea pig) at 1000 microg/ml using the radiometric (BACTEC) method. The extracts were also tested against six fast growing ATCC strains of M. vaccae using the broth microdilution method. The methanol extracts from both leaves, stem bark and root bark of Cola accuminata and from the leaves and stem bark of C. nitida and C. milleni were not active at the highest concentration of 1000 microg/ml. Only the methanol extract of root bark for both C. nitida and C. milleni were found to be potent against both M. bovis and strains of M. vaccae. The minimum inhibitory concentration (MIC) of C. nitida against M. bovis is 125 microg/ml while the MIC of C. milleni against M. bovis is 62.5 microg/ml after at least 6 days of inhibition with growth index (GI) units lesser than or equal to the change in GI units inoculated with a 1/100 of the BACTEC inoculum for a control vial. The minimum inhibitory concentration of C. milleni against the six ATCC strain of M. vaccae ranged from 62.5 microg/ml to 250 microg/ml while for C. nitida ranged from 500 microg/ml to above 1000microg/ml. Evidently, C. milleni has the highest inhibitory activity against both M. bovis and strains of M. vaccae used. Rifampicin, the positive control used has strong activity against M. bovis at the tested concentration of 5 microg and 10 microg/ml and 4 to 8 microg/ml against the six strains of M. vaccae. Copyright 2004 John Wiley & Sons, Ltd.
Projecting Medical Supply Requirements for a Highly Mobile Forward Resuscitative Surgery System
1999-10-01
Sulfate Injection 0.5MG/ML 20ML Vial 6505013859409 Ephedrine Sulfate Injection 50MG/ML Ampoules 100S 6505012385634 Epinephrine Injection 1ML Syringe...Container 12S 6505010410558 Theopental Sodium Injection 500MG Vial 25S 6505012582004 Vecuronium Bromide Injection IMG/ML 10ML Vial 10S...Sterile 1GM Container 12S 6505012582004 Vecuronium Bromide Injection IMG/ML 10ML Vial 10S 6135009857845 Battery Nonrechargeable 1.5Volt Size AA 24S
Moreno, C; Garrigó, M; Sánchez, F; Coll, P
1994-05-01
The usefulness of the microscopic examination of Bactec 12B and 13A growth medium as a method for the possible identification of M. tuberculosis complex, M. avium complex, M. xenopi, and M. kansasii was performed out to guide the selection of different genetic identification probes and, in the case of M. xenopi, the selection of the temperature of subcultures incubation. Upon detection of an index of growth greater than 100 in Bactec tubes, staining was performed by the Ziehl-Neelsen technique. On the basis of the morphology observed, the possible identification was performed by genetic probes. Subcultures were used for definitive identification. Three hundred forty-four positive samples were studied by radiometric technique. A total of 190 strains were identified as M. tuberculosis, 88 strains as M. avium-intracellulare (MAI), 33 strains as M. xenopi, 14 strains as M. kansasii and 19 strains were identified as: M. gordonae (10), unpigmented rapid growth microbacteria (7), and M. simiae (2). Sensitivity, specificity, positive predictive value, and negative predictive value were 97.9%, 95.4%, 96.4%, and 97.3%, respectively for M. tuberculosis complex, 84.0%, 99.2%, 97.3% 94.7% for M. avium complex; 63.6%, 98.3%, 80.7%, 96.2% for M. xenopi; 35.7%, 98.1%, 45.5% 97.2% for M. kansasii. The morphology of M. tuberculosis complex examined in the radiometric system in useful to differentiate this species from other microbacteria (MOTT), allowing the selection of specific probe used. Within the MOTT, M. avium complex also has morphological characteristics which are useful for its differentiation, the morphology usually described for the remaining species was frequently not observed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinstein, M.P.; Mirrett, S.; Reller, L.B.
1988-05-01
The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilusmore » species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi.« less
Comparison between Bactec Peds Plus F Broth and Conventional Medium for Vitreous Culture.
Tabatabaei, Seyed Ali; Tabatabaei, Seyed Mehdi; Soleimani, Mohammad; Hejrati, Bahman; Mirshahi, Ahmad; Khadabandeh, Alireza; Ahmadraji, Aliasghar; Valipour, Niloofar
2018-05-10
To evaluate the yield of Bactec Peds Plus F broth for vitreous sample culture in cases with infectious endophthalmitis in comparison to conventional medium. Consecutive cases of clinically suspected endophthalmitis were prospectively enrolled in this study. Cultures of the vitreous sample were performed in both Bactec Peds Plus F broth and conventional mediums. Forty eyes of 40 patients who were clinically suspected of infectious endophthalmitis with different etiologies were enrolled in this study. The positive culture yield was 50% and 35% in Bactec Peds Plus F broth and conventional mediums, respectively (p = 0.07). The result of Bactec group was not significantly different among patients who had a history of intravitreal antibiotic injection (p > 0.05) (Table 2). However, results of the conventional method were significantly negative in the previous intravitreal antibiotic injection group (p = 0.02). There was no correlation between the methods of vitreous sampling in both culture methods. Although the difference between two culture methods was not statistically significant in this study, Bactec Peds Plus F broth showed higher positive culture yield in patients with a history of intravitreal antibiotic injection.
Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Spanu, Teresa
2014-01-01
We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization–time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. PMID:25031441
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandy, J.H.; Pruden, E.L.; Cox, F.R.
1983-12-01
Simple and rapid Bactec methodologies for the determination of neat (unaltered) and heat stable urease activity of mycobacteria are presented. Clinical isolates (63) and stock cultures (32)--consisting of: M. tuberculosis (19), M. bovis (5), M. kansasii (15), M. marinum (4), M. simiae (3), M. scrofulaceum (16), M. gordonae (6), M. szulgai (6), M. flavescens (1), M. gastri (1), M. intracellulare (6), M. fortuitum-chelonei complex (12), and M. smegmatis (1)--were tested for neat urease activity by Bactec radiometry. Mycobacterial isolates (50-100 mg wet weight) were incubated at 35 degrees C for 30 minutes with microCi14C-urea. Urease-positive mycobacteria gave Bactec growth indexmore » (GI) values greater than 100 units, whereas urease-negative species gave values less than 10 GI units. Eighty-three isolates possessing neat urease activity were heated at 80 degrees C for 30 minutes followed by incubation at 35 degrees C for 30 minutes with 1 microCi14C-urea. Mycobacterium tuberculosis-bovis complex demonstrated heat-stable urease activity (GI more than 130 units) and could be distinguished from mycobacteria other than tuberculosis (MOTT), which gave GI values equal to or less than 40 units.« less
Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa
2017-01-01
Objective: The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Materials and Methods: Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. Results: The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. Conclusion: The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis. PMID:29123441
Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa
2017-10-01
The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis.
Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan
2015-01-01
Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS. PMID:26554930
Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan
2015-01-01
Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.
Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Sanguinetti, Maurizio; Spanu, Teresa
2014-10-01
We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥ 16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤ 5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization-time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?
Mueller-Premru, Manica; Jeverica, Samo; Papst, Lea; Nagy, Elisabeth
2017-06-01
We studied the performance characteristics of two blood culture (BC) bottles/systems, (i) BacT/ALERT-FN Plus/3D (bioMérieux, Marcy l'Étoile, France) and (ii) BACTEC-Lytic/9000 (Becton Dickinson, Sparks, USA) for detection of growth and time-to-positivity (TTP) against a balanced and diverse collection of anaerobic bacterial strains (n = 48) that included reference strains (n = 19) and clinical isolates (n = 29) of 32 species (15 Gram-negative and 17 Gram-positive). Standard suspension of bacteria was inoculated to each bottle in duplicates and incubated in the corresponding system. Overall, 62.5% (n = 30) of strains were detected by both BC bottle types. Comparing the two, 70.8% (n = 34) and 79.2% (n = 38) of strains were detected by BacT/ALERT-FN Plus and BACTEC-Lytic bottles, respectively (p = 0.38). Among Gram-negative anaerobes (n = 25) the detection rate was 76.0% (n = 19) vs. 92.0% (n = 23) (p = 0.22), respectively. Among Gram-positive anaerobes (n = 23) the detection rate was 65.2% (n = 15) in both bottles (p = 1). The average TTP per bottle was calculated only for the strains detected by both systems (n = 30) and was 40.85 h and 28.08 h for BacT/ALERT-FN Plus and BACTEC-Lytic, respectively (p < 0.001). The mean difference was 12.76 h (95% CI: 6.21-19-31 h). Six anaerobic strains were not detected by any system, including Gram-negative Porphyromonas gingivalis, and five Gram-positive strains: Finegoldia magna, Peptostreptococcus anaerobius, Propionibacterium acnes, Clostridium novyi and Clostridium clostridioforme. Furthermore, Eggerthella lenta and Prevotella bivia were detected only by BacT/ALERT-FN Plus, while Prevotella disiens and Prevotella intermedia were detected only by BACTEC-Lytic bottles. There were no major differences in detection rate among clinical and reference strains. Anaerobic bacteria represent a minority of BC isolates, however, far from ideal detection rate was observed in this study for both tested bottle/system combinations. Nevertheless, in those cases where both gave positive signal, BACTEC-Lytic was superior to BacT/ALERT FN Plus with 12.76 h shorter mean TTP. Improvements of media in blood culture bottles available for detection of anaerobes are warranted. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Wang, Ming-Cheng; Lin, Wei-Hung; Yan, Jing-Jou; Fang, Hsin-Yi; Kuo, Te-Hui; Tseng, Chin-Chung; Wu, Jiunn-Jong
2015-08-01
Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) is a valuable method for rapid identification of blood stream infection (BSI) pathogens. Integration of MALDI-TOF MS and blood culture system can speed the identification of causative BSI microorganisms. We investigated the minimal microorganism concentrations of common BSI pathogens required for positive blood culture using BACTEC FX and for positive identification using MALDI-TOF MS. The time to detection with positive BACTEC FX and minimal incubation time with positive MALDI-TOF MS identification were determined for earlier identification of common BSI pathogens. The minimal microorganism concentrations required for positive blood culture using BACTEC FX were >10(7)-10(8) colony forming units/mL for most of the BSI pathogens. The minimal microorganism concentrations required for identification using MALDI-TOF MS were > 10(7) colony forming units/mL. Using simulated BSI models, one can obtain enough bacterial concentration from blood culture bottles for successful identification of five common Gram-positive and Gram-negative bacteria using MALDI-TOF MS 1.7-2.3 hours earlier than the usual time to detection in blood culture systems. This study provides an approach to earlier identification of BSI pathogens prior to the detection of a positive signal in the blood culture system using MALDI-TOF MS, compared to current methods. It can speed the time for identification of BSI pathogens and may have benefits of earlier therapy choice and on patient outcome. Copyright © 2013. Published by Elsevier B.V.
The adsorption of 99Tcm dimercaptosuccinic acid onto injection vials.
Millar, A M
1984-04-01
It is common practice to dispense radiopharmaceuticals into empty sterile vials for dispatch to the departments where they are to be administered. It has been noted that on withdrawal of technetium-99m dimercaptosuccinic acid injections (99Tcm-DMSA) which have been dispensed into such vials, the activities obtained are lower than expected. To explain this phenomenon, the adsorption of 99Tcm-DMSA onto commercially available, empty, sterile vials has been investigated. The 99Tcm-DMSA solutions were prepared using kits from two manufacturers and were tested in vials from two manufacturers and the original kit vials. Adsorption of 99Tcm in one DMSA/vial combination after storage for 4 h was 49.6% (+/- 4.5% S.E.M.), but typically, adsorption was approximately 12% after 4 h. Although rate of adsorption was found to vary with storage conditions, no conditions satisfactorily overcame the effect. In vials from one manufacturer, the 99Tcm adsorption was predominantly on the glass, while in vials from the other, it was predominantly on the rubber stopper. It is concluded that the compatibility between vials and radiopharmaceuticals must be investigated in the hospital radiopharmacy.
Investigating factors leading to fogging of glass vials in lyophilized drug products.
Abdul-Fattah, Ahmad M; Oeschger, Richard; Roehl, Holger; Bauer Dauphin, Isabelle; Worgull, Martin; Kallmeyer, Georg; Mahler, Hanns-Christian
2013-10-01
Vial "Fogging" is a phenomenon observed after lyophilization due to drug product creeping upwards along the inner vial surface. After the freeze-drying process, a haze of dried powder is visible inside the drug product vial, making it barely acceptable for commercial distribution from a cosmetic point of view. Development studies were performed to identify the root cause for fogging during manufacturing of a lyophilized monoclonal antibody drug product. The results of the studies indicate that drug product creeping occurs during the filling process, leading to vial fogging after lyophilization. Glass quality/inner surface, glass conversion/vial processing (vial "history") and formulation excipients, e.g., surfactants (three different surfactants were tested), all affect glass fogging to a certain degree. Results showed that the main factor to control fogging is primarily the inner vial surface hydrophilicity/hydrophobicity. While Duran vials were not capable of reliably improving the level of fogging, hydrophobic containers provided reliable means to improve the cosmetic appearance due to reduction in fogging. Varying vial depyrogenation treatment conditions did not lead to satisfying results in removal of the fogging effect. Processing conditions of the vial after filling with drug product had a strong impact on reducing but not eliminating fogging. Copyright © 2013 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinstein, M.P.; Mirrett, S.; Reimer, L.G.
1989-03-01
In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield ofmore » streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory.« less
Aboagye, G; Rowe, M T
2018-07-01
The recovery of Mycobacterium avium subspecies paratuberculosis (Map) from the environment can be a laborious process - owing to Map being fastidious, its low number, and also high numbers of other microbial populations in such settings. Protocols i.e. filtration, decontamination and modified elution were devised to recover Map from spiked water sediments. Three culture media: Herrold's Egg Yolk Media (HEYM), Middlebrook 7H10 (M-7H10) and Bactec 12B were then employed to grow the organism following its elution. In the sterile sediment samples the recovery of Map was significant between the time of exposure for each of HEYM and M-7H10, and insignificant between both media (P < 0.05). However, in the non-sterile sediment samples, the HEYM grew other background microflora including moulds at all the times of exposure whilst 4 h followed by M-7H10 culture yielded Map colonies without any background microflora. Using sterile samples only for the Bactec 12B, the recovery of Map decreased as time of exposure increased. Based on these findings, M-7H10 should be considered for the recovery of Map from the natural environment including water sediments where the recovery of diverse microbial species remains a challenge. Map is a robust pathogen that abides in the environment. In water treatment operations, Map associates with floccules and other particulate matter including sediments. It is also a fastidious organism, and its detection and recovery from the water environment is a laborious process and can be misleading within the abundance of other mycobacterial species owing to their close resemblance in phylogenetic traits. In the absence of a reliable recovery method, Map continues to pose public health risks through biofilm in household water tanks, hence the need for the development of a reliable recovery protocol to monitor the presence of Map in water systems in order to curtail its public health risks. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurinat, J.; Kesterson, M.; Hensel, S.
The documented safety analysis for the Savannah River Site evaluates the consequences of a postulated 1000 °C fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage vial. To enable evaluation of the dose consequences, pressure transients and venting flow rates have been calculated for exposure of the storage vial to the fire. A standard B vial with a capacity of approximately 8 cc was selected for analysis. The analysis compares the pressurization rate from heating and evaporationmore » of moisture adsorbed onto the plutonium oxide contents of the vial with the pressure loss due to venting of gas through the threaded connection between the vial cap and body. Tabulated results from the analysis include maximum pressures, maximum venting velocities, and cumulative vial volumes vented during the first 10 minutes of the fire transient. Results are obtained for various amounts of oxide in the vial, various amounts of adsorbed moisture, different vial orientations, and different surface fire exposures.« less
Evaluation of BACTEC 9240 blood culture system by using high-volume aerobic resin media.
Schwabe, L D; Thomson, R B; Flint, K K; Koontz, F P
1995-01-01
The BACTEC 9240 blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is one of three automated, continuous-monitoring systems that is widely used in clinical laboratories. The BACTEC 9240 was compared with the BACTEC NR 660 for the detection of organisms and bacteremic episodes; time to detection of positive cultures; number of false-positive and false-negative cultures; and time needed to load, process, and perform quality control functions by using high-volume aerobic media. Blood specimens (5,282) were inoculated in equal volumes (5 to 10 ml per bottle) into BACTEC Plus Aerobic/F (9240 system) and BACTEC Plus NR26 (660 system) bottles. Clinically significant isolates were detected in 6.6% of cultures, representing 348 microorganisms and 216 bacteremic episodes. Two hundred forty-eight microorganisms were detected by both systems, 48 by the 9240 only and 52 by the 660 only (P = not significant). Of the bacteremic episodes, 158 were detected by both systems, 27 by the 9240 only and 31 by the 660 only (P = not significant). Analysis of data by month revealed equivalent recovery rates for both systems, with the exception of a 30-day period at one study site during which the 660 system detected significantly more microorganisms. Following a proprietary hardware design retrofit of the 9240 instrument, detection rates were again equivalent for the remaining three months at this study site. Positive cultures detected by both systems were detected an average of 4.3 h faster by the 9240 system (21 versus 25.3 h). The numbers of false-positive cultures for the 9240 and 660 systems were 40 (1.0%) and 9 ( < 1.0%), respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7494044
Smith, Geoff; Jeeraruangrattana, Yowwares; Ermolina, Irina
2018-06-22
Through vial impedance spectroscopy (TVIS) is a product non-invasive process analytical technology which exploits the frequency dependence of the complex impedance spectrum of a composite object (i.e. the freeze-drying vial and its contents) in order to track the progression of the freeze-drying cycle. This work demonstrates the use of a dual electrode system, attached to the external surface of a type I glass tubing vial (nominal capacity 10 mL) in the prediction of (i) the ice interface temperatures at the sublimation front and at the base of the vial, and (ii) the primary drying rate. A value for the heat transfer coefficient (for a chamber pressure of 270 µbar) was then calculated from these parameters and shown to be comparable to that published by Tchessalov[1]. Copyright © 2018. Published by Elsevier B.V.
Eby, Elizabeth L; Smolen, Lee J; Pitts, Amber C; Krueger, Linda A; Andrews, Jeffrey Scott
2014-12-01
Estimate budgetary impact for skilled nursing facility converting from individual patient supply (IPS) delivery of rapid-acting insulin analog (RAIA) 10-mL vials or 3-mL prefilled pens to 3-mL vials. A budget-impact model used insulin volume purchased and assumptions of length of stay (LOS), daily RAIA dose, and delivery protocol to estimate the cost impact of using 3-mL vials. Skilled nursing facility. Medicare Part A patients. Simulations conducted using 12-month current and future scenarios. Comparisons of RAIA use for 13- and 28-day LOS. RAIA costs and savings, waste reduction. For patients with 13-day LOS using 20 units/day of IPS insulin, the model estimated a 70% reduction in RAIA costs and units purchased and a 95% waste reduction for the 3-mL vial compared with the 10-mL vial. The estimated costs for prefilled pen use were 58% lower than for use of 10-mL vials. The incremental savings associated with 3-mL vial use instead of prefilled pens was 28%, attributable to differences in per-unit cost of insulin in vials versus prefilled pens. Using a more conservative scenario of 28-day LOS at 20 units/day, the model estimated a 40% reduction in RAIA costs and units purchased, resulting in a 91% reduction in RAIA waste for the 3-mL vial, compared with 10-mL vial. Budget-impact analysis of conversion from RAIA 10-mL vials or 3-mL prefilled pens to 3-mL vials estimated reductions in both insulin costs and waste across multiple scenarios of varying LOS and patient daily doses for skilled nursing facility stays.
Shah, Sudeep R; Shenai, Shubhada; Desai, Devendra C; Joshi, Anand; Abraham, Philip; Rodrigues, Camilla
2010-11-01
Traditionally, the Lowenstein Jensen (LJ) medium has been used for culturing Mycobacterium tuberculosis. In abdominal tuberculosis (TB), the reported yield from tissue culture is between 20% and 60%. Liquid cultures are reported to give a higher yield but there is little data available in abdominal TB. To compare the yield of TB culture with BACTEC 460TB liquid medium and LJ medium for patients with suspected abdominal TB and determine cost effectiveness. This prospective study was done in consecutive cases with clinical, radiological, endoscopic/surgical, and histological suspicion of abdominal TB. Tissue biopsies obtained at colonoscopy or surgery were processed and plated on LJ medium as well as the BACTEC 460TB system. NAP (ρ-nitro-α-acetylamino-β-hydroxy-propiophenone) differentiation was carried out to determine species. The cost of each method and cost per yield were calculated. Of the 29 cases, 22 cases (76%) were positive on BACTEC 460TB culture while 14 (48%) were positive on LJ medium giving a 64% increment in yield. However, the culture of one patient grew on LJ medium, where the BACTEC 460TB was negative. The additional cost of BACTEC 460TB is Rs. 460 and LJ is Rs. 40. Samples from patients with abdominal TB should be processed on both liquid and LJ medium. For high yield, the use of a liquid culture medium system is essential.
Tienpont, Bart; David, Frank; Pereira, Alberto; Sandra, Pat
2011-11-18
A new generic pyrolysis unit (PyroVial) is presented. Pyrolysis is carried out in a 2 mL autosampler vial placed in a XYZ robot for automated pyrolysis as well as for pre- and post-pyrolysis treatment of the sample. Analysis of the volatiles is performed by headspace analysis while the semi- and non-volatiles are extracted from the pyrolysate with an organic solvent. The features of the PyroVial are such that all chromatographic techniques can be applied. The pyrolysis unit is discussed in terms of its technical features and its performance is illustrated with applications including conventional pyrolysis, in situ and post-pyrolysis derivatization, reaction pyrolysis and catalytic cracking. Copyright © 2011 Elsevier B.V. All rights reserved.
Ditter, Dominique; Mahler, Hanns-Christian; Roehl, Holger; Wahl, Michael; Huwyler, Joerg; Nieto, Alejandra; Allmendinger, Andrea
2018-04-01
The appropriate selection of adequate primary packaging, such as the glass vial, rubber stopper, and crimp cap for parenteral products is of high importance to ensure product stability, microbiological quality (integrity) during storage as well as patient safety. A number of issues can arise when inadequate vial material is chosen, and sole compliance to hydrolytic class I is sometimes not sufficient when choosing a glass vial. Using an appropriate pre-treatment, such as surface modification or coating of the inner vial surface after the vial forming process the glass container quality is often improved and interactions of the formulation with the surface of glass may be minimized. This study aimed to characterize the inner surface of different type I glass vials (Exp33, Exp51, Siliconized, TopLyo™ and Type I plus®) at the nanoscale level. All vials were investigated topographically by colorimetric staining and Scanning Electron Microscopy (SEM). Glass composition of the surface was studied by Time-of-Flight - Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS), and hydrophobicity/hydrophilicity of the inner surface was assessed by dye tests and surface energy measurements. All containers were studied unprocessed, as received from the vendor, i.e. in unwashed and non-depyrogenized condition. Clear differences were found between the different vial types studied. Especially glass vials without further surface modifications, like Exp33 and Exp51 vials, showed significant (I) vial-to-vial variations within one vial lot as well as (II) variations along the vertical axis of a single vial when studying topography and chemical composition. In addition, differences and heterogeneity in surface energy were found within a given tranche (circumferential direction) of Exp51 as well as Type I plus® vials. Most consistent quality was achieved with TopLyo™ vials. The present comprehensive characterization of surface properties of the different vial types may serve as basis to further guide the selection of adequate primary packaging based on the desired quality target product profile and to support studies of glass surface interactions with formulations. The proposed analytical method panel can be used for characterization of future glass vials either before delivery to the manufacturer or drug product manufacturing. Copyright © 2018 Elsevier B.V. All rights reserved.
Parveen, Seema; Kaur, Simleen; David, Selwyn A Wilson; Kenney, James L; McCormick, William M; Gupta, Rajesh K
2011-10-19
Most biological products, including vaccines, administered by the parenteral route are required to be tested for sterility at the final container and also at various stages during manufacture. The sterility testing method described in the Code of Federal Regulations (21 CFR 610.12) and the United States Pharmacopoeia (USP, Chapter <71>) is based on the observation of turbidity in liquid culture media due to growth of potential contaminants. We evaluated rapid microbiological methods (RMM) based on detection of growth 1) by adenosine triphosphate (ATP) bioluminescence technology (Rapid Milliflex(®) Detection System [RMDS]), and 2) by CO(2) monitoring technologies (BacT/Alert and the BACTEC systems), as alternate sterility methods. Microorganisms representing Gram negative, Gram positive, aerobic, anaerobic, spore forming, slow growing bacteria, yeast, and fungi were prepared in aliquots of Fluid A or a biological matrix (including inactivated influenza vaccines) to contain approximately 0.1, 1, 10 and 100 colony forming units (CFU) in an inoculum of 10 ml. These preparations were inoculated to the specific media required for the various methods: 1) fluid thioglycollate medium (FTM) and tryptic soy broth (TSB) of the compendial sterility method (both membrane filtration and direct inoculation); 2) tryptic soy agar (TSA), Sabouraud dextrose agar (SDA) and Schaedler blood agar (SBA) of the RMDS; 3) iAST and iNST media of the BacT/Alert system and 4) Standard 10 Aerobic/F and Standard Anaerobic/F media of the BACTEC system. RMDS was significantly more sensitive in detecting various microorganisms at 0.1CFU than the compendial methods (p<0.05), whereas the compendial membrane filtration method was significantly more sensitive than the BACTEC and BacT/Alert methods (p<0.05). RMDS detected all microorganisms significantly faster than the compendial method (p<0.05). BacT/Alert and BACTEC methods detected most microorganisms significantly faster than the compendial method (p<0.05), but took almost the same time to detect the slow growing microorganism P. acnes, compared to the compendial method. RMDS using SBA detected all test microorganisms in the presence of a matrix containing preservative 0.01% thimerosal, whereas the BacT/Alert and BACTEC systems did not consistently detect all the test microorganisms in the presence of 0.01% thimerosal. RMDS was compatible with inactivated influenza vaccines and aluminum phosphate or aluminum hydroxide adjuvants at up to 8 mg/ml without any interference in bioluminescence. RMDS was shown to be acceptable as an alternate sterility method taking 5 days as compared to the 14 days required of the compendial method. Isolation of microorganisms from the RMDS was accomplished by re-incubation of membranes with fresh SBA medium and microbial identification was confirmed using the MicroSEQ Identification System. BacT/Alert and BACTEC systems may be applicable as alternate methods to the compendial direct inoculation sterility method for products that do not contain preservatives or anti-microbial agents. Published by Elsevier Ltd.
Barrier protection capacity of flip-top pharmaceutical vials.
Hilliard, James G; Cambronne, Eric D; Kirsch, Jeffrey R; Aziz, Michael F
2013-05-01
To test the sterility of medication vial tops after removal of the dust cover, and to survey anesthesia providers for their perceptions surrounding medication vials and sterility. Experimental design and survey instrument. Ambulatory and hospital care setting. Anesthesia providers in the United States. A two-question survey was distributed to anesthesia providers in the U.S. An experimental model was conducted on a total of 42 medication vials. The access diaphragms of medication vials were sampled after routine handling, after exposure to aerosolized contamination with the dust cover on, and after submersion into a bacterial medium with the dust cover on. 878 responses to Question 1 and 876 responses to Question 2 were received. Fifty-two percent of respondents declared that the access diaphragm was sterile in routine conditions, and 43% felt that (or were unsure if) the dust cover would prevent contamination when exposed to a contaminated environment. Two of the 12 vials sampled in the routine handling model had microbial contaminants on the access diaphragm. No growth was found on any of the 15 vials exposed to aerosolized E. coli. Seven of the 15 vials in the submersion model were contaminated. Anesthesia providers in the U.S. possess contradictory opinions of, and unclear knowledge about, the sterility of rubber stoppers used to access medications, and also the barrier capacity of a vial's dust cover. Standard anesthetic medication vial dust covers do not offer barrier protection against the growth of pathogens. Copyright © 2013 Elsevier Inc. All rights reserved.
Somily, Ali Mohammed; Habib, Hanan Ahmed; Torchyan, Armen Albert; Sayyed, Samina B; Absar, Muhammed; Al-Aqeel, Rima; Binkhamis, A Khalifa
2018-01-01
Bloodstream infections are associated with high rates of morbidity and mortality. Rapid detection of bloodstream infections is important in achieving better patient outcomes. Compare the time-to-detection (TTD) of the new BacT/Alert Virtuo and the BACTEC FX automated blood culture systems. Prospective simulated comparison of two instruments using seeded samples. Medical microbiology laboratory. Blood culture bottles were seeded in triplicate with each of the standard ATCC strains of aerobes, anaerobes and yeast. TTD was calculated as the length of time from the beginning of culture incubation to the detection of bacterial growth. TTD for the various tested organisms on the two microbial detection systems. The 99 bottles of seeded blood cultures incubated in each of the blood culture systems included 21 anaerobic, 39 aerobic and 39 pediatric bottles. The BacT/Alert Virtuo system exhibited significantly shorter TTD for 72.7 % of the tested organisms compared to BACTEC FX system with a median difference in mean TTD of 2.1 hours (interquartile range: 1.5-3.5 hours). The BACTEC FX system was faster in 15.2% (5/33) of microorganisms, with a median difference in mean TTD of 25.9 hours (IQR: 9.1-29.2 hours). TTD was significantly shorter for most of the microorganisms tested on the new BacT/Alert Virtuo system compared to the BACTEC FX system. Use of simulated cultures to assess TTD may not precisely represent clinical blood cultures. None.
Bhat, B Vishnu; Prasad, P; Ravi Kumar, Venkata Banda; Harish, B N; Krishnakumari, K; Rekha, Anand; Manjunath, G; Adhisivam, B; Shruthi, B
2016-05-01
To compare the clinical outcome of a multiplex polymerase chain reaction (PCR) based molecular diagnostic method -- Syndrome Evaluation System (SES) directed treatment strategy vs. standard of care (blood culture) directed treatment strategy for neonatal sepsis. This randomized controlled trial (RCT) included 385 neonates with sepsis who were randomized into two groups -- SES and control (BACTEC). Both tests were performed for all the neonates. However, in the SES group, the results of SES test were revealed to the treating clinicians, while in the control group, SES results were withheld. Two ml of blood was drawn from each baby. One aliquot was sent for blood culture, whereas the remaining aliquot was sent for SES. Babies were then administered empirical IV antibiotics and given supportive care. Further antibiotic changes, if required were done in SES and control groups based on their respective reports. The microbiological profile, immediate outcome, duration of hospital stay, number of antibiotics used and readmission within a month in both groups were compared. SES was better than BACTEC in identifying the causative organism in both the groups (68 % vs. 18 % in SES group and 72 % vs. 18 % in control group). SES had 100 % concordance with blood culture by BACTEC. Detection of bacteria and fungi were four and ten-fold higher respectively with SES when compared to BACTEC culture. Microbiological diagnosis was rapid with SES compared to BACTEC (7 h vs. 72 h). Treatment based on SES resulted in significantly less mortality (3 % vs. 18 %). Readmission rate, duration of hospital stay and change in antibiotics were also significantly less in SES group. This new molecular based diagnostic system (SES) helps in rapid and accurate diagnosis of neonatal sepsis and reduces mortality and morbidity in affected neonates.
21 CFR 522.1862 - Sterile pralidoxime chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...
De Meyer, L; Van Bockstal, P-J; Corver, J; Vervaet, C; Remon, J P; De Beer, T
2015-12-30
Spin-freezing as alternative freezing approach was evaluated as part of an innovative continuous pharmaceutical freeze-drying concept for unit doses. The aim of this paper was to compare the sublimation rate of spin-frozen vials versus traditionally frozen vials in a batch freeze-dryer, and its impact on total drying time. Five different formulations, each having a different dry cake resistance, were tested. After freezing, the traditionally frozen vials were placed on the shelves while the spin-frozen vials were placed in aluminum vial holders providing radial energy supply during drying. Different primary drying conditions and chamber pressures were evaluated. After 2h of primary drying, the amount of sublimed ice was determined in each vial. Each formulation was monitored in-line using NIR spectroscopy during drying to determine the sublimation endpoint and the influence of drying conditions upon total drying time. For all tested formulations and applied freeze-drying conditions, there was a significant higher sublimation rate in the spin-frozen vials. This can be explained by the larger product surface and the lower importance of product resistance because of the much thinner product layers in the spin frozen vials. The in-line NIR measurements allowed evaluating the influence of applied drying conditions on the drying trajectories. Copyright © 2015 Elsevier B.V. All rights reserved.
Ruiz, P.; Zerolo, F. J.; Casal, M. J.
2000-01-01
The ESP Culture System II was evaluated for its capacity to test the susceptibility of 389 cultures of Mycobacterium tuberculosis to streptomycin, rifampin, ethambutol, and isoniazid. Good agreement with results with the BACTEC TB 460 was found. ESP II is a reliable, rapid, and automated method for performing susceptibility testing. PMID:11101619
Zheng, Shuwei; Ng, Tong Yong; Li, Huihua; Tan, Ai Ling; Tan, Thuan Tong; Tan, Ban Hock
2016-01-01
Mortality for candidemia ranges from 15% to 35%. Current guidelines recommend inoculating blood into three aerobic and three anaerobic blood culture bottles when candidemia is suspected, without mention of a fungal blood culture bottle. To determine the value of the BACTEC Myco/F Lytic blood culture media in the diagnosis of fungemia. A two-year retrospective cross-sectional study was performed for patients who had fungemia with submitted BACTEC Plus Aerobic/F (Aer), BACTEC Plus Anaerobic/F (Anaer) or Myco/F Lytic (Myco) blood culture bottles. The detection rate of fungemia was 77.4% in 93 patients with contemporaneously submitted blood culture bottles when limited to only Aer/Anaer culture results. The detection rate improved significantly with the addition of the Myco culture bottle results (p<0.0001). A logistic regression model showed that Myco culture bottle submissions were less useful for patients with appropriate anti-fungal therapy administered within 48 hours [OR = 0.18, 95% CI = (0.06, 0.49), p = 0.001] and those with fungal growth detected within 48 hours [OR = 0.33, 95% CI = (0.12, 0.89), p = 0.001]. Among a subset of patients with concordant blood culture results, those with Myco culture bottles submission allowed earlier fungal detection and speciation by at least one day in 27.5% and 25.0% of the cases respectively. Our study highlights the importance of a dedicated fungal blood culture when fungemia is clinically suspected. Nearly a quarter of fungemias may be missed if a fungal blood culture is not performed.
Inoue, Yusuke; Abe, Yutaka; Kikuchi, Kei; Miyatake, Hiroki; Watanabe, Atsushi
2017-01-01
Low-energy characteristic x-rays emitted by 111 In and 123 I sources are easily absorbed by the containers of the sources, affecting radioactivity measurements using a dose calibrator. We examined the effects of different containers on the estimated activities. The radioactivities of 111 In, 123 I, 201 Tl, and 99m Tc were measured in containers frequently employed in clinical practice in Japan. The 111 In measurements were performed in the vials A and B of the 111 In-pentetreotide preparation kit and in the plastic syringe. The activities of 123 I-metaiodobenzylguanidine and 201 Tl chloride were measured in the prefilled glass syringes and plastic syringes. The milking vial, vial A, vial B, and plastic syringe were used to assay 99m Tc. For 111 In and 123 I, measurements were performed with and without a copper filter. The filter was inserted into the well of the dose calibrator to absorb low-energy x-rays. The relative estimate was defined as the ratio of the activity estimated with the dose calibrator to the standard activity. The estimated activities varied greatly depending on the container when 111 In and 123 I sources were assayed without the copper filter. The relative estimates of 111 In were 0.908, 1.072, and 1.373 in the vial A, vial B, and plastic syringe, respectively. The relative estimates of 123 I were 1.052 and 1.352 in the glass syringe and plastic syringe, respectively. Use of the copper filter eliminated the container-dependence in 111 In and 123 I measurements. Container-dependence was demonstrated in neither 201 Tl nor 99m Tc measurements. The activities of 111 In and 123 I estimated with a dose calibrator differ greatly among the containers. Accurate estimation may be attained using the container-specific correction factor or using the copper filter.
Detection and Characteristics of Rifampicin-Resistant Isolates of Mycobacterium tuberculosis.
Cherednichenko, A G; Dymova, M A; Solodilova, O A; Petrenko, T I; Prozorov, A I; Filipenko, M L
2016-03-01
Genotyping and analysis the drug resistance of 59 isolates of M. tuberculosis obtained from patients living in Altai Territory were performed using a BACTEC MGIT 960 fluorometric system by means of VNTR typing (variable number tandem repeat), PCR-RFLP analysis, and sequence analysis. The occurrence frequency was highest for isolates of the Beijing family (n=30, 50.8%). Analysis of mutation spectrum in the rpoB gene associated with rifampicin resistance revealed the major mutation (codon 531 of the rpoB gene) in 93% samples, which allows us to use rapid test systems.
Prediction of the acoustic and bubble fields in insonified freeze-drying vials.
Louisnard, O; Cogné, C; Labouret, S; Montes-Quiroz, W; Peczalski, R; Baillon, F; Espitalier, F
2015-09-01
The acoustic field and the location of cavitation bubble are computed in vials used for freeze-drying, insonified from the bottom by a vibrating plate. The calculations rely on a nonlinear model of sound propagation in a cavitating liquid [Louisnard, Ultrason. Sonochem., 19, (2012) 56-65]. Both the vibration amplitude and the liquid level in the vial are parametrically varied. For low liquid levels, a threshold amplitude is required to form a cavitation zone at the bottom of the vial. For increasing vibration amplitudes, the bubble field slightly thickens but remains at the vial bottom, and the acoustic field saturates, which cannot be captured by linear acoustics. On the other hand, increasing the liquid level may promote the formation of a secondary bubble structure near the glass wall, a few centimeters below the free liquid surface. These predictions suggest that rather complex acoustic fields and bubble structures can arise even in such small volumes. As the acoustic and bubble fields govern ice nucleation during the freezing step, the final crystal's size distribution in the frozen product may crucially depend on the liquid level in the vial. Copyright © 2015 Elsevier B.V. All rights reserved.
Grandy, Jonathan J; Gómez-Ríos, German A; Pawliszyn, Janusz
2015-09-04
In this work, a highly reproducible standard gas generating vial is proposed. The vial is comprised of a silicon diffusion pump oil spiked with an appropriate calibration compound, such as modified McReynolds probes (benzene, 2-pentanone, pyridine, 1-nitropropane, 1-pentanol, and n-octane), and then mixed with polystyrene/divinylbenzene (PS/DVB) particles. The concentrations of these compounds in gaseous headspace were found to substantially decrease in comparison to previously developed hydrocarbon pump oil based vials; hence, the amount of standard loaded onto SPME fibers was at most, half that of the previous vial design. Depletion for all compounds after 208 successive extractions was shown to be less than 3.5%. Smaller quantities of standards being used resulted in a vial that depleted slower while remaining statistically repeatable over a wider number of runs. Indeed, it was found that depletion could be largely predicted by using a mass balance theoretical model. This behavior allowed a further increase in the number of loadings that could be performed repeatedly. At a 95% level of confidence, the ANOVA test demonstrated that the prepared vials were statistically identical, with no significant intra- or inter-batch differences. In addition, it was found that vials stored under different conditions (e.g. under light exposure, room temperature, and within a refrigerator) were stable over 10 weeks. Silicon based vials proved to be ideal for performing instrument quality control and loading of internal standards onto fibers, both of which are of great importance when performing on-site analysis using portable GC-MS instrumentation and high throughput determinations in laboratory. Copyright © 2015 Elsevier B.V. All rights reserved.
Vohra, Rais; Kelner, Michael; Clark, Richard F
2009-01-01
Crotaline Polyvalent Ovine Fab antivenom (CroFab, Savage Laboratories and Protherics Inc., Brentwood, TN, USA) preparation requires that the lyophilized powder be manually reconstituted before use. We compared automated methods for driving the product into solution with the standard manual method of reconstitution, and the effect of repeated rinsing of the product vial, on the per-vial availability of antivenom. Normal saline (NS, 10 mL) was added to 12 vials of expired CroFab. Vials were assigned in pairs to each of six mixing methods, including one pair mixed manually as recommended by the product package insert. Each vial's contents were diluted to a final volume of 75 mL of normal saline. Protein concentration was measured with a colorimetric assay. The fluid left in each vial was removed and the vial was washed with 10 mL NS. Total protein yield from each step was calculated. There was no significant change in protein yield among three of five automated mixing methods when compared to manual reconstitution. Repeat rinsing of the product vial with an additional 10 mLs of fluid added to the protein yield regardless of the mixing method used. We found slightly higher protein yields with all automated methods compared to manual mixing, but only two of five comparisons with the standard mixing method demonstrated statistical significance. However, for all methods tested, the addition of a second rinsing and recovery step increased the amount of protein recovered considerably, presumably by allowing solution of protein trapped in the foamy residues. Automated mixing methods and repeat rinsing of the product vial may allow higher protein yields in the preparation of CroFab antivenom.
Taipale, Sami J; Sonninen, Eloni
2009-08-30
The precise delta(13)C value of dissolved inorganic carbon (DIC) is important for various types of ecological studies. Without a preservation agent, microbial degradation of organic compounds continues in water samples and the delta(13)C value of DIC will become more depleted with time. HgCl(2) or acidification is often used to prevent microbial activity in water samples collected for carbon isotope ratio analyses of DIC. Mercury compounds are toxic and result in waste disposal problems. Other inhibiting agents or preservation methods are therefore needed. Two possible solutions are to use copper sulphate (CuSO(4)) as a preservative agent or to acidify water samples with phosphoric acid (H(3)PO(4)) within 12 mL measurement Exetainers (septum-capped vials). We prepared a set of lake water samples in three types of vials: glass vials with silicone/PTFE septa, high-density polyethylene vials (HD-PE, scintillation vials) and Exetainers (12 mL) with butyl rubber septa. Samples in glass and PE vials were preserved with and without CuSO(4), whereas lake water was injected into the Exetainer and acidified with H(3)PO(4). Isotope ratios were measured in two laboratories over 6 months. The delta(13)C values of DIC systematically increased with storage time for samples preserved in glass and PE vials with and without CuSO(4). A strong correlation between a decrease of CO(2) concentration and an increase in DIC delta(13)C values was found. The delta(13)C values and DIC concentrations were stable for 6 months in acidified samples stored in Exetainers with butyl rubber septa. Therefore, we conclude that the best method for up to 6 months of storage is to inject samples in the field into butyl rubber septum capped Exetainers containing H(3)PO(4), thereby avoiding the use of preservatives. 2009 John Wiley & Sons, Ltd.
[Tuberculous meningoencephalitis--own observations].
Garlicki, Aleksander; Kluba-Wojewoda, Urszula; Bociaga-Jasik, Monika; Kalinowska-Nowak, Anna; Sobczyk-Krupiarz, Iwona; Mach, Tomasz
2003-01-01
Nine cases of the tuberculous meningoencephalitis in adult men and women treated in years 1993-2000 have been presented. The diagnosis was established on the basis of clinical picture and examination of the cerebrospinal fluid (CSF). Routine analysis of CSF was done, as well as the microscopic examination, biological assay, and culture on the Lowenstein-Jensena medium and using Bactec 460 TB system. Only in one case Mycobacterium tuberculosis was found in the smear of CSF stained by Ziehl-Nielsen method. In one case the biologic assay was positive and Mycobacterium tuberculosis was cultured on Lowenstein-Jensen medium. In another 4 cases the pathogen was detected by Bactec 460 TB technique. In 4 cases Mycobacterium tuberculosis was also cultured from the secretion of the respiratory tract, and in one patient urine. On chest X-ray characteristic changes for pulmonary tuberculosis were observed in 5 cases (56%). Seven patients (78%) had hydrocephalus detected on CT scan of the head. One patient died, one (11%) developed persistent complication in form of spastic paralysis of lower extremities and sphincters dysfunction. Seven patients (78%) recovered completely after the 12 months therapy with standard chemotherapeutic regimen for tuberculosis.
Barreto, Leonardo Bruno Paz Ferreira; Lourenço, Maria Cristina da Silva; Rolla, Valéria Cavalcanti; Veloso, Valdiléia Gonçalves; Huf, Gisele
2014-01-01
To compare the accuracy of the amplified Mycobacterium tuberculosis direct (AMTD) test with reference methods for the laboratory diagnosis of tuberculosis in HIV-infected patients. This was a study of diagnostic accuracy comparing AMTD test results with those obtained by culture on Löwenstein-Jensen (LJ) medium and by the BACTEC Mycobacteria Growth Indicator Tube 960 (BACTEC MGIT 960) system in respiratory samples analyzed at the Bioassay and Bacteriology Laboratory of the Oswaldo Cruz Foundation Evandro Chagas Clinical Research Institute in the city of Rio de Janeiro, Brazil. We analyzed respiratory samples collected from 118 patients, of whom 88 (74.4%) were male. The mean age was 36.6 ± 10.6 years. Using the AMTD test, the BACTEC MGIT 960 system, and LJ culture, we identified M. tuberculosis complex in 31.0%, 29.7%, and 27.1% of the samples, respectively. In comparison with LJ culture, the AMTD test had a sensitivity, specificity, positive predictive value, and negative predictive value of 87.5%, 89.4%, 75.7%, and 95.0%, respectively, for LJ culture, whereas, in comparison with the BACTEC MGIT 960 system, it showed values of 88.6%, 92.4%, 83.8%, and 94.8%, respectively. The AMTD test showed good sensitivity and specificity in the population studied, enabling the laboratory detection of M. tuberculosis complex in paucibacillary respiratory specimens.
Jorajuria, S; Raphalen, C; Dujardin, V; Daas, A
2015-01-01
Organization (WHO) International Standard (IS) for bleomycin complex A2/B2. Eight laboratories from different countries participated. Potencies of the candidate material were estimated by microbiological assays with sensitive micro-organisms. To ensure continuity between consecutive batches, the 1(st) IS for bleomycin complex A2/B2 was used as a reference. Based on the results of the study, the 2(nd) IS for bleomycin complex A2/B2 was adopted at the meeting of the WHO Expert Committee for Biological Standardization (ECBS) in 2014 with an assigned potency of 12 500 International Units (IU) per vial. The 2(nd) IS for bleomycin complex A2/B2 is available from the European Directorate for the Quality of Medicines & HealthCare (EDQM).
Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Y.; Wuu, Cheng-Shie; Maryanski, Marek J.
2010-02-15
The dose response of the BANG 3 polymer gel dosimeter (MGS Research Inc., Madison, CT) was studied using the OCTOPUS laser CT scanner (MGS Research Inc., Madison, CT). Six 17 cm diameter and 12 cm high Barex cylinders, and 18 small glass vials were used to house the gel. The gel phantoms were irradiated with 6 and 10 MV photons, as well as 12 and 16 MeV electrons using a Varian Clinac 2100EX. Three calibration methods were used to obtain the dose response curves: (a) Optical density measurements on the 18 glass vials irradiated with graded doses from 0 tomore » 4 Gy using 6 or 10 MV large field irradiations; (b) optical-CT scanning of Barex cylinders irradiated with graded doses (0.5, 1, 1.5, and 2 Gy) from four adjacent 4x4 cm{sup 2} photon fields or 6x6 cm{sup 2} electron fields; and (c) percent depth dose (PDD) comparison of optical-CT scans with ion chamber measurements for 6x6 cm{sup 2}, 12 and 16 MeV electron fields. The dose response of the BANG 3 gel was found to be linear and energy independent within the uncertainties of the experimental methods (about 3%). The slopes of the linearly fitted dose response curves (dose sensitivities) from the four field irradiations (0.0752{+-}3%, 0.0756{+-}3%, 0.0767{+-}3%, and 0.0759{+-}3% cm{sup -1} Gy{sup -1}) and the PDD matching methods (0.0768{+-}3% and 0.0761{+-}3% cm{sup -1} Gy{sup -1}) agree within 2.2%, indicating a good reproducibility of the gel dose response within phantoms of the same geometry. The dose sensitivities from the glass vial approach are different from those of the cylindrical Barex phantoms by more than 30%, owing probably to the difference in temperature inside the two types of phantoms during gel formation and irradiation, and possible oxygen contamination of the glass vial walls. The dose response curve obtained from the PDD matching approach with 16 MeV electron field was used to calibrate the gel phantom irradiated with the 12 MeV, 6x6 cm{sup 2} electron field. Three-dimensional dose distributions from the gel measurement and the Eclipse planning system (Varian Corporation, Palo Alto, CA) were compared and evaluated using 3% dose difference and 2 mm distance-to-agreement criteria.« less
Lee, Lauren J; Li, Qian; Reynolds, Matthew W; Pawaskar, Manjiri D; Corrigan, Sheila M
2011-01-01
Studies examining outcomes of different insulin delivery systems are limited. The objective of this study was to compare healthcare utilization, costs, adherence, and hypoglycemia rates in patients with type 2 diabetes mellitus (T2DM) initiating rapid-acting insulin analog (RAIA) using prefilled pen versus vial/syringe. A retrospective analysis was conducted using a US claims database (1/1/2007 to 12/31/2008). Inclusion criteria were: ≥18 years old, with T2DM, ≥12 months of continuous eligibility, and new to RAIA. Difference-in-difference analyses after propensity score matching were conducted to compare changes in outcomes from 6 months prior to and 6 months after initiating RAIA with a prefilled pen versus vial/syringe (Wilcoxon rank-sum test for costs and t-test for other outcomes). Categories of utilization and costs (2009 USD) included total and diabetes-related inpatient, outpatient, and emergency room. Adherence was measured by proportion of days covered (PDC). Hypoglycemia was identified using ICD-9-CM codes. Baseline characteristics were similar between the prefilled pen (n = 239) and vial/syringe (n = 590) cohorts after matching. Adherence to RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (PDC: 54.6 vs. 45.2%, p < 0.001). While the increase in diabetes-related pharmacy costs from before to after initiating RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (+$900 vs. +$607, p < 0.001), the prefilled pen cohort was associated with greater reductions in the total diabetes-related costs (-$235 vs. +$61, p = 0.006) and the utilization of oral anti-hyperglycemic agents (-1.3 vs. -0.7, p = 0.016). There were no significant differences in other outcomes. Claims databases do not provide optimal measures for adherence or T2DM severity, and only capture hypoglycemia events requiring clinical intervention. Initiating RAIA with a prefilled pen was associated with better adherence and greater reduction in total diabetes-related costs than a vial/syringe. There was no significant difference in total healthcare costs.
Eby, Elizabeth L; Boye, Kristina S; Lage, Maureen J
2013-10-01
To compare all-cause and diabetes-related resource utilization and healthcare charges among adults with type 2 diabetes mellitus who initiated therapy with mealtime insulin disposable pens or vials. Data were obtained from the Innovus inVision database from January 1, 2006 through June 30, 2010. Generalized linear models with a gamma distribution and log link estimated the association between medical charges and use of mealtime insulin pens vs vials in the 1 year post-index date, while generalized linear models with a negative binomial distribution estimated resource utilization. Controlling for patient characteristics, general health, and patient copayments, insulin therapy initiation with disposable pens, compared to vials, was associated with significantly fewer all-cause hospitalizations (1.45 vs. 1.66; p < 0.0001) as well as a significantly shorter hospital length of stay (2.16 days vs. 3.53 days; p < 0.0001). Pen use, compared to vials, was also associated with significantly fewer diabetes-related hospitalizations (1.36 vs. 1.47; p < 0.0001), and shorter hospital length of stay (1.12 days vs. 1.72 days; p < 0.0001). Despite higher diabetes-related drug charges ($3593 vs. $2755; p < 0.0001) associated with the use of pens, results showed significantly lower all-cause total healthcare charges ($42,150 vs. $53,340; p < 0.0001) and significantly lower diabetes-related total healthcare charges ($12,722 vs. $14,540; p < 0.0001) for patients who initiated therapy on mealtime insulin with pens compared to vials. Data were drawn from administrative claims and included only patients with medical and outpatient prescription drug benefit coverage. Hence, the results may not be generalizable. The retrospective analyses relied on diagnostic codes to identify patients, assess patient general health, and determine other values, rather than formal, clinical assessments. The analyses did not include indirect healthcare costs. The administration of mealtime insulin via disposable pens, compared to vials, was associated with a significant reduction in all-cause and diabetes-related resource utilization and total healthcare charges.
Fujimori, Kiyoshi; Lee, Hans; Phillips, Joseph; Nashed-Samuel, Yasser
The European Pharmacopeia surface test to analyze the hydrolytic resistance is a common industrial method to understand and ensure the quality of produced glass vials. Hydrolytic resistance is evaluated by calculating the alkalinity of water extract from autoclaved vials by titration. As an alternative to this titration technique, a conductivity technique was assessed, which directly measures the ions in the water extract. A conductivity meter with a 12 mm diameter electrode was calibrated with a 100 μS/cm conductivity standard and carryover minimized by rinsing the probe in a water beaker per analysis. The limit of quantification at 1 μS/cm was determined as having a signal-to-noise ratio of 3 compared with the water blank. The conductivity method was selective for glass-composing elements (boron, sodium, aluminum, silicon, potassium, and calcium) within the vial extract. Accuracies of spiked conductivity standard within the range of 1 to 100 μS/cm were ±7% and had linearity with coefficient of determination (R 2 ) of ≥0.9999. Intraday precision had a relative standard deviation (RSD) (n = 5) of ≤6% for spiked conductivity standard within the range of 1 to 100 μS/cm. Interday precision had a RSD (n = 4) of ≤6% for 10 vials from three glass vial lots. Conductivity of water extracts from nine sets of seven lots of glass vials had a precise linear relationship [R 2 = 0.9876, RSD = 1% (n = 9)] with titration volumes of the same lots. Conductivity results in μS/cm could be converted to titration volumes in milliliters by a conversion factor of 0.0275. The simplicity, sample stability, and individual vial analysis of the conductivity technique were more advantageous than the current titration technique. The quality of glass vials used as primary containers in the pharmaceutical industry is of concern due to recent observations of glass flake-like delamination, or lamellae, under specific storage conditions. The current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. As an alternative to the European Pharmacopoeia method, the vial extracts were analyzed for conductivity, which directly determines the level of ions that were readily extracted from the vial surfaces. Lower quality glass would have greater surface defects that lead to higher ions extracted and higher conductivity value. The conductivity method was found to be suitable to measure the ions in water extracts and showed strong correlation with alkalinity. The advantage of the conductivity method over the alkalinity method was greater ease, lower volume requirements, stability, and flexibility in analysis. © PDA, Inc. 2017.
Polyglycerol coatings of glass vials for protein resistance.
Höger, Kerstin; Becherer, Tobias; Qiang, Wei; Haag, Rainer; Friess, Wolfgang; Küchler, Sarah
2013-11-01
Proteins are surface active molecules which undergo non-specific adsorption when getting in contact with surfaces such as the primary packaging material. This process is critical as it may cause a loss of protein content or protein aggregation. To prevent unspecific adsorption, protein repellent coatings are of high interest. We describe the coating of industrial relevant borosilicate glass vials with linear methoxylated polyglycerol, hyperbranched polyglycerol, and hyperbranched methoxylated polyglycerol. All coatings provide excellent protein repellent effects. The hyperbranched, non-methoxylated coating performed best. The protein repellent properties were maintained also after applying industrial relevant sterilization methods (≥200 °C). Marginal differences in antibody stability between formulations stored in bare glass vials and coated vials were detected after 3 months storage; the protein repellent effect remained largely stable. Here, we describe a new material suitable for the coating of primary packaging material of proteins which significantly reduces the protein adsorption and thus could present an interesting new possibility for biomedical applications. Copyright © 2013 Elsevier B.V. All rights reserved.
Miyake, Noriko; Chong, Yong; Nishida, Ruriko; Nagasaki, Yoji; Kibe, Yasushi; Kiyosuke, Makiko; Shimomura, Takeshi; Shimono, Nobuyuki; Shimoda, Shinji; Akashi, Koichi
2015-11-01
In our hospital, positive blood culture rates of Helicobacter cinaedi dramatically increased after introducing the Bactec system. A simulated culture model of H. cinaedi bacteremia demonstrated no positive signals using the BacT/Alert system, despite efficient growth in bottles. Clinically suspected H. cinaedi bacteremia should be monitored more closely when using the BacT/Alert system, preferably with subcultivation after 7days of incubation. Copyright © 2015 Elsevier Inc. All rights reserved.
Diagnosis of brucellosis by using blood cultures.
Ruiz, J; Lorente, I; Pérez, J; Simarro, E; Martínez-Campos, L
1997-01-01
The performances of three blood culture systems, Hemoline performance diphasic medium (bioMérieux, Marcy l'Etoile, France), Bactec Plus Aerobic/F* (Becton Dickinson, Paramus, N.J.), and Vital Aer (bioMérieux), were compared for the diagnosis of 17 cases of brucellosis. By using a 5-day incubation protocol, positive results were 52.9, 82.4, and 11.8%, respectively. When the protocol was extended to 7 days, the results were 76.5, 94.1, and 47.1%, respectively. Bactec was the fastest system (P < 0.05). PMID:9276429
Chen, Yi-Hao; Wu, Pei-Chang; Shiea, Jentaie; Lo, Li-Hua; Wu, Yi-Chen; Kuo, Hsi-Kung
2009-02-01
The aim of this study was to determine the sterility, stability, and efficacy of a commercially available brand of bevacizumab for 6 months of being stored in multidose vials at 4 degrees C. Bevacizumab was aseptically and repeatedly drawn four to five times from new vials into syringes for clinical use within the first month; the remaining bevacizumab was left in the vials and refrigerated at 4 degrees C for 0, 1, 3, and 6 months for research. Each time before bevacizumab was withdrawn and every weekend when it was not sampled, the rubber top of each vial was disinfected by using 10% povidone-iodine solution and an isopropyl alcohol wipe. Each vial had been sampled for less than 12 times during the experimental periods. All vials were analyzed for microbial growth. The stability of bevacizumab was analyzed by MALDI-TOF MS (matrix-assisted laser desorption ionization/time-of-flight mass spectrometry). The efficacy of bevacizumab was analyzed by enzyme-linked immunosorbent assay (ELISA). At each time period, bevacizumab was mixed with vascular endothelial growth factor (VEGF)-165 and left undisturbed for 3 h. The efficacy of bevacizumab was then evaluated by measuring the concentration of residual-free VEGF-165. No microbial growth was obtained from any of the bevacizumab samples during each time period, indicating that the bevacizumab stored at 4 degrees C after the vials had been pierced remained sterile. MALDI-TOF MS analysis revealed that the 1-, 3-, and 6-month samples were stable, and there were no molecular-weight changes among any of the samples. The level of degradation of bevacizumab at 1, 3, and 6 months was compared with that of the control (0 months). The results of ELISA showed less than 10% degradation at all time periods. This study suggests that if aseptic precautions are followed while using bevacizumab, the contents of multiple-dose vials stored at 4 degrees C will remain sterile. The anti-VEGF activity of bevacizumab stored at 4 degrees C will remain stable for up to 6 months.
Jin, Yang-Hui; Shi, Shi-Yuan; Zheng, Qi; Shen, Jian; Ying, Xiao-Zhang; Wang, Yi-Fan
2017-09-25
To investigate the application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance. The 109 pus specimens were obtained from patients who were primaryly diagnosed as spinal tuberculosis. All of the pus specimens were detected by acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay to definite the differences in sensitivity and specificity of mycobacterium tuberculosis among detecting methods. Pus specimens obtained by different methods were deteceded by MTB/RIF test to analyze the self-influence on Xpert MTB/RIF test. The result of liquid fast culturing by BACTEC MGIT 960 was used as the gold standard; and the value of Xpert MTB/RIF assay in detecting rifampin resistance was analyzed. The sensitivity of acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay were 25.92%, 48.15%, 77.78%, respectively. The sensitivity of pus specimens obtained from open surgery, ultrasound positioning puncture and biopsy the sensitivity were 83.78%, 76.47%, 44.68% respectively deteceded by MTB/RIF test. According to the gold standard of the results of liquid fast culturing by BACTEC MGIT 960 assay, the sensitivity and specificity of Xpert MTB/RIF assay in detecting rifampin resistance were 80%(4/5) and 90.70%(39/43), respectively. Xpert MTB/RIF assay has higher value in diagnosis of spinal tuberculosi, and also can detect rifampin resistance. The number of mycobacterium tuberculosis in pus specimens has a great influence in the sensitivity of Xpert MTB/RIF assay.
Tommaselli, Giovanni A; Formisano, Carmen; Di Carlo, Costantino; Fabozzi, Annamaria; Nappi, Carmine
2012-09-01
One of the most frequent and distressing complications of the tension-free vaginal tape obturator (TVT-O) procedure for stress urinary incontinence (SUI) is groin pain, which may be related to the surgical technique or to the tape. The aim of this study was to evaluate the impact of a more limited dissection and a more medial trocar trajectory in TVT-O positioning on postoperative pain. Seventy-two SUI patients were randomized to undergo TVT-O either with the traditional technique (group A) or a modified procedure (reduced paraurethral dissection and a more medial trocar trajectory) (group B). Visual analog scale pain scores 12 h, 24 h, and 1 month after the procedure, number of analgesic vials, objective cure rate, and patient functional and quality of life scores 6 months after the procedure were evaluated. Data were analyzed by the Student's t test for parametric variables, the Mann-Whitney U and Wilcoxon tests for nonparametric variables, and Fisher's exact test for categorical variables. Pain scores were significantly lower in group B compared with group A 24 h after surgery (P = 0.01). Pain scores significantly decreased from 12-24 h postoperatively to 1 month follow-up in both groups (P < 0.001). No significant differences were observed in the number of analgesic vials administered, cure rates, and questionnaire scores between the two groups. More limited dissection and a more medial trocar trajectory of TVT-O seem to reduce postoperative groin pain at 24 h after the procedure, but not the analgesic requirement.
Schneid, Stefan C; Gieseler, Henning; Kessler, William J; Pikal, Michael J
2009-09-01
The goal of this work was to demonstrate the application of Tunable Diode Laser Absorption Spectroscopy (TDLAS) as a non-invasive method to determine the average product temperature of the batch during primary drying. The TDLAS sensor continuously measures the water vapor concentration and the vapor flow velocity in the spool connecting the freeze-dryer chamber and condenser. Vapor concentration and velocity data were then used to determine the average sublimation rate (g/s) which was subsequently integrated to evaluate the amount of water removed from the product. Position dependent vial heat transfer coefficients (K(v)) were evaluated using the TDLAS sensor data for 20 mL vials during sublimation tests with pure water. TDLAS K(v) data showed good agreement to K(v) data obtained by the traditional gravimetric procedure. K(v) for edge vials was found to be about 20-30% higher than that of center vials. A weighted K(v) was then used to predict a representative average product temperature from TDLAS data in partial and full load freeze drying runs with 5%, 7.5%, or 10% (w/w) sucrose, mannitol, and glycine solutions. TDLAS product temperatures for all freeze-drying runs were within 1-2 degrees C of "center vial" steady state thermocouple data.
Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F
2011-01-01
Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.
Outbreak of pyogenic abscesses after diphtheria and tetanus toxoids and pertussis vaccination.
Simon, P A; Chen, R T; Elliott, J A; Schwartz, B
1993-05-01
Nine children who received diphtheria and tetanus toxoids and pertussis vaccine from the same vial at a clinic in Colorado developed pyogenic abscesses at the site of injection. Eight abscesses required surgical drainage and five children were hospitalized. Group A Streptococcus (GAS) was cultured from eight wounds and Staphylococcus aureus was also isolated from four. Epidemiologic investigation revealed that within the hour of the first child's vaccination, three children had been diagnosed in the clinic with GAS pharyngitis. GAS recovered from repeat throat swabs from two of these children and the eight case-isolates were all serotype M-12, T-12 and had identical immunoblot patterns on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Laboratory simulation studies demonstrated that GAS can survive for at least 4 days on the external surface of a vaccine vial rubber stopper and contaminate needles inserted through the stopper. Swabbing the stopper with 70% isopropyl alcohol resulted in effective disinfection. To prevent potential contamination meticulous attention to sterile technique is important when withdrawing vaccine from multidose vaccine vials.
Pryce, Todd M; Palladino, Silvano; Price, Diane M; Gardam, Dianne J; Campbell, Peter B; Christiansen, Keryn J; Murray, Ronan J
2006-04-01
We report a direct polymerase chain reaction/sequence (d-PCRS)-based method for the rapid identification of clinically significant fungi from 5 different types of commercial broth enrichment media inoculated with clinical specimens. Media including BacT/ALERT FA (BioMérieux, Marcy l'Etoile, France) (n = 87), BACTEC Plus Aerobic/F (Becton Dickinson, Microbiology Systems, Sparks, MD) (n = 16), BACTEC Peds Plus/F (Becton Dickinson) (n = 15), BACTEC Lytic/10 Anaerobic/F (Becton Dickinson) (n = 11) bottles, and BBL MGIT (Becton Dickinson) (n = 11) were inoculated with specimens from 138 patients. A universal DNA extraction method was used combining a novel pretreatment step to remove PCR inhibitors with a column-based DNA extraction kit. Target sequences in the noncoding internal transcribed spacer regions of the rRNA gene were amplified by PCR and sequenced using a rapid (24 h) automated capillary electrophoresis system. Using sequence alignment software, fungi were identified by sequence similarity with sequences derived from isolates identified by upper-level reference laboratories or isolates defined as ex-type strains. We identified Candida albicans (n = 14), Candida parapsilosis (n = 8), Candida glabrata (n = 7), Candida krusei (n = 2), Scedosporium prolificans (n = 4), and 1 each of Candida orthopsilosis, Candida dubliniensis, Candida kefyr, Candida tropicalis, Candida guilliermondii, Saccharomyces cerevisiae, Cryptococcus neoformans, Aspergillus fumigatus, Histoplasma capsulatum, and Malassezia pachydermatis by d-PCRS analysis. All d-PCRS identifications from positive broths were in agreement with the final species identification of the isolates grown from subculture. Earlier identification of fungi using d-PCRS may facilitate prompt and more appropriate antifungal therapy.
Angeby, K A; Jureen, P; Giske, C G; Chryssanthou, E; Sturegård, E; Nordvall, M; Johansson, A G; Werngren, J; Kahlmeter, G; Hoffner, S E; Schön, T
2010-05-01
To describe wild-type distributions of the MIC of fluoroquinolones for Mycobacterium tuberculosis in relation to current critical concentrations used for drug susceptibility testing and pharmacokinetic/pharmacodynamic (PK/PD) data. A 96-stick replicator on Middlebrook 7H10 medium was used to define the MICs of ciprofloxacin, ofloxacin, moxifloxacin and levofloxacin for 90 consecutive clinical strains and 24 drug-resistant strains. The MICs were compared with routine BACTEC 460 susceptibility results and with MIC determinations in the BACTEC MGIT 960 system in a subset of strains using ofloxacin as a class representative. PK/PD data for each drug were reviewed in relation to the wild-type MIC distribution. The wild-type MICs of ciprofloxacin, ofloxacin, moxifloxacin and levofloxacin were distributed from 0.125 to 1, 0.25 to 1, 0.032 to 0.5 and 0.125 to 0.5 mg/L, respectively. The MIC data correlated well with the BACTEC 960 MGIT and BACTEC 460 results. PD indices were the most favourable for levofloxacin, followed by moxifloxacin, ofloxacin and ciprofloxacin. We propose S (susceptible)
Becherer, Tobias; Grunewald, Christian; Engelschalt, Vivienne; Multhaup, Gerhard; Risse, Thomas; Haag, Rainer
2015-03-31
Coatings based on dendritic polyglycerol (dPG) were investigated for their use to control nonspecific protein adsorption in an assay targeted to analyze concentrations of a specific protein. We demonstrate that coating of the sample vial with dPG can significantly increase the recovery of an antibody after incubation. First, we determine the concentration dependent loss of an antibody due to nonspecific adsorption to glass via quartz crystal microbalance (QCM). Complementary to the QCM measurements, we applied the same antibody as analyte in an surface plasmon resonance (SPR) assay to determine the loss of analyte due to nonspecific adsorption to the sample vial. For this purpose, we used two different coatings based on dPG. For the first coating, which served as a matrix for the SPR sensor, carboxyl groups were incorporated into dPG as well as a dithiolane moiety enabling covalent immobilization to the gold sensor surface. This SPR-matrix exhibited excellent protein resistant properties and allowed the immobilization of amyloid peptides via amide bond formation. The second coating which was intended to prevent nonspecific adsorption to glass vials comprised a silyl moiety that allowed covalent grafting to glass. For demonstrating the impact of the vial coating on the accuracy of an SPR assay, we immobilized amyloid beta (Aβ) 1-40 and used an anti-Aβ 1-40 antibody as analyte. Alternate injection of analyte into the flow cell of the SPR device from uncoated and coated vials, respectively gave us the relative signal loss (1-RUuncoated/RUcoated) caused by the nonspecific adsorption. We found that the relative signal loss increases with decreasing analyte concentration. The SPR data correlate well with concentration dependent non-specific adsorption experiments of the analyte to glass surfaces performed with QCM. Our measurements show that rendering both the sample vial and the sensor surface is crucial for accurate results in protein assays. Copyright © 2015 Elsevier B.V. All rights reserved.
Therese, K Lily; Gayathri, R; Balasubramanian, S; Natrajan, S; Madhavan, H N
2012-01-01
Multidrug-resistant TB (MDR-TB) has been reported in almost all parts of the world. Childhood TB is accorded low priority by national TB control programs. Probable reasons include diagnostic difficulties, limited resources, misplaced faith in BCG and lack of data on treatment. Good data on the burden of all forms of TB among children in India are not available. To study the drug sensitivity pattern of tuberculosis in children aged from 3 months to 18 years and the outcome of drug-resistant tuberculosis by BACTEC culture system and PCR-based DNA sequencing technique. This is a retrospective study. One hundred and fifty-nine clinical specimens were processed for Ziehl-Neelsen stain, Mycobacterial culture by BACTEC method, phenotypic DST for first-line drugs for Mycobacterium tuberculosis (M. tuberculosis) isolates and PCR-based DNA sequencing was performed for the M. tuberculosis isolates targeting rpoB, katG, inhA, oxyR-ahpC, rpsL, rrs and pncA. Out of the 159 Mycobacterial cultures performed during the study period, 17 clinical specimens (10.7%) were culture positive for M. tuberculosis. Among the 17 M. tuberculosis isolates, 2 were multidrug-resistant TB. PCR-based DNA sequencing revealed the presence of many novel mutations targeting katG, inhA, oxyR-ahpC and pncA and the most commonly reported mutation Ser531Leu in the rpoB gene. This study underlines the urgent need to take efforts to develop methods for rapid detection and drug susceptibility of tubercle bacilli in the pediatric population.
Hibler, Susanne; Wagner, Christophe; Gieseler, Henning
2012-03-01
In order to optimize a freeze-drying cycle, information regarding the heat transfer characteristics of the container system is imperative. Two most recently developed tubing (TopLyo™) and molded (EasyLyo™) vial designs were compared with a standard serum tubing and molded vial, a polymer vial (TopPac™), and an amber molded EasyLyo™. In addition, the impact of methodology on the determination of reliable vial heat transfer coefficient (K(v) ) data is examined in detail. All K(v) s were gravimetrically determined by sublimation tests with pure water at 50, 100, 200, and 400 mTorr. In contrast to the traditional assumption that molded vials exhibit inefficient heat transfer characteristics, these vials showed a very similar performance compared with their serum tubing counterparts in the relevant pressure range for freeze-drying. At 100 mTorr, the TopLyo™ center vials show only 4% higher K(v) values than the EasyLyo™ center vials. All glass vials outmatch the polymer vial in terms of heat transfer, up to 30% elevated heat transfer for the TopLyo™ center vials at 400 mTorr. Sublimation tests have demonstrated to be a valuable tool to investigate the heat transfer characteristics of vials, but results are dependent on methodology. New developments in molded vial manufacturing lead to improved heat transfer performance. Copyright © 2011 Wiley Periodicals, Inc.
Hazardous drug residue on exterior vial surfaces: evaluation of a commercial manufacturing process.
Power, Luci A; Sessink, Paul J M; Gesy, Kathy; Charbonneau, Flay
2014-04-01
Hazardous drug residue on the exterior surface of drug vials poses a potential risk for exposure of health care workers involved in handling these products. The purpose of this article is to heighten the awareness of this serious issue and to evaluate a commercial manufacturing process for removing and containing hazardous drug (HD) residue on exterior vial surfaces. Additionally, findings from this study are interpreted, incorporated into the current body of evidence, and discussed by experts in this field. This study includes separate evaluations for the presence or absence of surface drug contamination on the vials of 3 HD products: 5-fluorouracil, cisplatin, and methotrexate. The drug products were packaged in vials using a patented prewashing/decontamination method, application of a polyvinylchloride (PVC) base, and use of clear glass vials. An additional step of encasing the vial in a shrink-wrapped sheath was used for 5-fluorouracil and cisplatin. Of all 5-fluorouracil (110 vials), methotrexate (60 vials), and cisplatin (60 vials) tested, only 2 had detectable amounts of surface residue. One 5-fluorouracil vial was found to have approximately 4 mg of 5-fluorouracil on the surface of the vial. The second contaminated vial was cisplatin, which was discovered to have 131 ng of platinum, equal to 200 ng of cisplatin or 0.2 μL of cisplatin solution, on the vial sheath. Using validated extraction and analytic methods, all but 2 of the 230 tested vials were found to be free of surface drug contamination. Pharmacy leaders need to take an active role in promoting the need for clean HD vials. Manufacturers should be required to provide their clients with data derived from externally validated analytic studies, reporting the level of HD contamination on the exterior of their vial products.
Akselband, Y; Cabral, C; Shapiro, D S; McGrath, P
2005-08-01
Control of multi-drug-resistant tuberculosis has been hampered by the lack of simple, rapid and sensitive methods for assessing bacterial growth and antimicrobial susceptibility. Due to the increasing incidence and high frequency of mutations, it is unlikely that culture methods will disappear in the foreseeable future. Therefore, the need to modernize methods for rapid detection of viable clinical isolates, at a minimum as a gold standard, will persist. Previously, we confirmed the feasibility of using the Gel Microdrop (GMD) Growth Assay for identifying sub-populations of resistant Mycobacteria by testing different laboratory strains. Briefly, this assay format relies on encapsulating single bacterium in agarose microspheres and identifying clonogenic growth using flow cytometry and fluorescent staining. In this study, we modified the GMD Growth Assay to make it suitable for clinical applications. We demonstrated the effectiveness and safety of this novel approach for detecting drug susceptibility in clinically relevant laboratory strains as well as clinical isolates of Mycobacterium tuberculosis. Correlation between results using the GMD Growth Assay format and results using two well characterized methods (Broth Microdilution MIC and BACTEC 460TB) was 87.5% and 90%, respectively. However, due to the inherent sensitivity of flow cytometry and the ability to detect small (<1%) sub-populations of resistant mycobacteria, the GMD Growth Assay identified more cases of drug resistance. Using 4 clinically relevant mycobacterial strains, we assessed susceptibility to primary anti-tuberculosis drugs using both the Broth Microdilution MIC method and the GMD Growth Assay. We performed 24 tests on isoniazid-resistant BCG, Mycobacterium tuberculosis H37Ra and Mycobacterium avium strains. The Broth Microdilution MIC method identified 7 cases (29.1%) of resistance to INH and EMB compared to the GMD Growth Assay which identified resistance in 10 cases (41.6%); in 3 cases (12.5%), resistance to INH and EMB was detected only with the GMD Growth Assay. In addition, using 20 Mycobacterium tuberculosis clinical isolates, we compared results using BACTEC 460TB method performed by collaborators and the GMD Growth Assay. Eight of 20 (40%) clinical isolates, which were not identified as drug-resistant using the conventional BACTEC 460TB method, were resistant to 1, 2, or 3 different concentrations of drugs using the GMD Growth Assay (13 cases of 140 experiments). In one case (isolate 1879), resistance to 10.0 microg/ml of STR detected using BACTEC 460TB method was not confirmed by the GMD Growth Assay. Thus, the overall agreement between these methods was 90% (14 discrepant results of 140 experiments). These data demonstrate that the GMD Growth Assay is an accurate and sensitive method for rapid susceptibility testing of Mycobacterium tuberculosis for use in clinical reference laboratory settings.
Mathaes, Roman; Mahler, Hanns-Christian; Buettiker, Jean-Pierre; Roehl, Holger; Lam, Philippe; Brown, Helen; Luemkemann, Joerg; Adler, Michael; Huwyler, Joerg; Streubel, Alexander; Mohl, Silke
2016-02-01
Parenteral drug products are protected by appropriate primary packaging to protect against environmental factors, including potential microbial contamination during shelf life duration. The most commonly used CCS configuration for parenteral drug products is the glass vial, sealed with a rubber stopper and an aluminum crimp cap. In combination with an adequately designed and controlled aseptic fill/finish processes, a well-designed and characterized capping process is indispensable to ensure product quality and integrity and to minimize rejections during the manufacturing process. In this review, the health authority requirements and expectations related to container closure system quality and container closure integrity are summarized. The pharmaceutical vial, the rubber stopper, and the crimp cap are described. Different capping techniques are critically compared: The most common capping equipment with a rotating capping plate produces the lowest amount of particle. The strength and challenges of methods to control the capping process are discussed. The residual seal force method can characterize the capping process independent of the used capping equipment or CCS. We analyze the root causes of several cosmetic defects associated with the vial capping process. Copyright © 2015 Elsevier B.V. All rights reserved.
Pikal, Michael J; Bogner, Robin; Mudhivarthi, Vamsi; Sharma, Puneet; Sane, Pooja
2016-11-01
This report presents calculations of the difference between the vial heat transfer coefficient of the "edge vial" and the "center vial" at all scales. The only scale-up adjustment for center vials is for the contribution of radiation from the shelf upon which the vial sits by replacing the emissivity of the laboratory dryer shelf with the emissivity of the production dryer shelf. With edge vials, scales-up adjustments are more complex. While convection is not important, heat transfer from the wall to the bands (surrounding the vial array) by radiation and directly from the band to the vials by both radiation and conduction is important; this radiation heat transfer depends on the emissivity of the vial and the bands and is nearly independent of the emissivity of the dryer walls. Differences in wall temperatures do impact the edge vial effect and scale-up, and estimates for wall temperatures are needed for both laboratory and manufacturing dryers. Auto-loading systems (no bands) may give different edge vial heat transfer coefficients than when operating with bands. Satisfactory agreement between theoretical predictions and experimental values of the edge vial effect indicate that results calculated from the theory are of useful accuracy. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Drop deployment system for crystal growth apparatus
NASA Technical Reports Server (NTRS)
Rhodes, Percy H. (Inventor); Snyder, Robert S. (Inventor); Pusey, Marc L. (Inventor)
1992-01-01
This invention relates to a crystal growth apparatus (10) generally used for growing protein crystals wherein a vapor diffusion method is used for growing the crystals. In this apparatus, a precipitating solution and a solution containing dissolved crystalline material are stored in separate vials (12, 14), each having a resilient diaphragm (28) across one end and an opening (24) with a puncturable septum (26) thereacross at an opposite end. The vials are placed in receptacles (30) having a manifold (41) with a manifold diaphragm (42) in contact with the vial diaphragm at one end of the receptacle and a hollow needle (36) for puncturing the septum at the other end of the manifold. The needles of each vial communicate with a ball mixer (40) that mixes the precipitate and protein solutions and directs the mixed solution to a drop support (64) disposed in a crystal growth chamber (16), the drop support being a tube with an inner bevelled surface (66) that provides more support for the drop (68) than the tubes of the prior art. A sealable storage region (70) intermediate the drop support and mixer provides storage of the drop (68) and the grown crystals.
Defining unnecessary disinfection procedures for single-dose and multiple-dose vials.
Buckley, T; Dudley, S M; Donowitz, L G
1994-11-01
Recommendations in the literature conflict on the necessity of disinfecting single-use vials prior to aspiration of fluid. Interventions to disinfect the stopper surface on multiple-dose vials vary considerably. To determine the necessity of alcohol disinfection of the stopper on single-dose vials and to compare povidone-iodine and alcohol versus alcohol-only disinfection of the stopper prior to each needle penetration on multiple-dose vials. The rubber stopper surfaces of 100 single-dose vials were cultured for the presence of bacteria. To determine the efficacy of two procedures for disinfection of multiple-dose vials, 87 stopper surfaces routinely disinfected with both povidone-iodine and alcohol were cultured for bacteria. After a change in practice, 100 multiple-dose vials routinely disinfected with alcohol only were cultured for the presence of bacteria. Of the cultures done on single-dose vial stoppers, 99% were sterile. A comparison of the two disinfection techniques for multiple-dose vials revealed that 83 (95%) of the 87 vials prepped with both povidone-iodine and alcohol were sterile, compared with all stoppers disinfected with alcohol only. This study shows the lack of necessity of any disinfection procedure on the rubber stopper of single-dose vials and the efficacy of alcohol only for disinfecting the stopper of multiple-dose vials.
Harausz, Elizabeth; Lusiba, John Kafuluma; Nsereko, Mary; Johnson, John L; Toossi, Zahra; Ogwang, Sam; Boom, W Henry; Joloba, Moses L
2015-04-01
The specificities and sensitivities of the Bactec mycobacterial growth indicator tube (MGIT) system for the recovery of Mycobacterium tuberculosis from pleural fluid are not statistically different than those of the Myco/F lytic liquid culture system. The time to positivity is shorter in the MGIT system (12.7 versus 20.7 days, respectively; P=0.007). The Myco/F lytic culture system may be an alternative to the MGIT system for diagnosing pleural tuberculosis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Van Bockstal, Pieter-Jan; Mortier, Séverine Thérèse F C; De Meyer, Laurens; Corver, Jos; Vervaet, Chris; Nopens, Ingmar; De Beer, Thomas
2017-05-01
Conventional pharmaceutical freeze-drying is an inefficient and expensive batch-wise process, associated with several disadvantages leading to an uncontrolled end product variability. The proposed continuous alternative, based on spinning the vials during freezing and on optimal energy supply during drying, strongly increases process efficiency and improves product quality (uniformity). The heat transfer during continuous drying of the spin frozen vials is provided via non-contact infrared (IR) radiation. The energy transfer to the spin frozen vials should be optimised to maximise the drying efficiency while avoiding cake collapse. Therefore, a mechanistic model was developed which allows computing the optimal, dynamic IR heater temperature in function of the primary drying progress and which, hence, also allows predicting the primary drying endpoint based on the applied dynamic IR heater temperature. The model was validated by drying spin frozen vials containing the model formulation (3.9mL in 10R vials) according to the computed IR heater temperature profile. In total, 6 validation experiments were conducted. The primary drying endpoint was experimentally determined via in-line near-infrared (NIR) spectroscopy and compared with the endpoint predicted by the model (50min). The mean ratio of the experimental drying time to the predicted value was 0.91, indicating a good agreement between the model predictions and the experimental data. The end product had an elegant product appearance (visual inspection) and an acceptable residual moisture content (Karl Fischer). Copyright © 2017 Elsevier B.V. All rights reserved.
Kirsch, L E; Nguyen, L; Moeckly, C S
1997-01-01
The development of mass spectrometry-based leak detection for pharmaceutical container integrity was undertaken to provide an alternative to microbial challenge testing. Standard 10-mL vials were modified to contain pinholes (0.5 to 10 microns) by affixing micropipettes with epoxy into 2-mm vial side wall holes. The absolute leak rate was determined using vials that were sealed in a tracer (helium) environment with butyl rubber stoppers and crimps. Alternatively leak rates were determined using vials that were sealed in room air and exposed to tracer under pressure (charging or bombing). Tracer leak rates were measured with mass spectrometry leak rate detectors. The absolute leak rate was correlated the squared nominal leak radius which suggested that the mode of gas flow through the glass pipette leaks was more turbulent than viscous even at low leak rates typically associated with viscous flow. The minimum observed absolute leak rate was about 10(-6.6) std cc/sec and was likely due to helium permeation through the rubber stoppers. Heat-stressed rubber stoppers did not affect the baseline absolute leak rate. Adsorption of helium tracer to the test unit surfaces was found to confound baseline leak rate measurement reliability but was eliminated as a source of variation by exposing the test units to ambient air for > or = 12 hours. The absolute leak rate and the leak rate measured after charging were related in a mathematically predictable way.
Hazardous Drug Residue on Exterior Vial Surfaces: Evaluation of a Commercial Manufacturing Process
Power, Luci A.; Sessink, Paul J. M.; Charbonneau, Flay
2014-01-01
Abstract Purpose: Hazardous drug residue on the exterior surface of drug vials poses a potential risk for exposure of health care workers involved in handling these products. The purpose of this article is to heighten the awareness of this serious issue and to evaluate a commercial manufacturing process for removing and containing hazardous drug (HD) residue on exterior vial surfaces. Additionally, findings from this study are interpreted, incorporated into the current body of evidence, and discussed by experts in this field. Methods: This study includes separate evaluations for the presence or absence of surface drug contamination on the vials of 3 HD products: 5-fluorouracil, cisplatin, and methotrexate. The drug products were packaged in vials using a patented prewashing/decontamination method, application of a polyvinylchloride (PVC) base, and use of clear glass vials. An additional step of encasing the vial in a shrink-wrapped sheath was used for 5-fluorouracil and cisplatin. Results: Of all 5-fluorouracil (110 vials), methotrexate (60 vials), and cisplatin (60 vials) tested, only 2 had detectable amounts of surface residue. One 5-fluorouracil vial was found to have approximately 4 mg of 5-fluorouracil on the surface of the vial. The second contaminated vial was cisplatin, which was discovered to have 131 ng of platinum, equal to 200 ng of cisplatin or 0.2 μL of cisplatin solution, on the vial sheath. Conclusion: Using validated extraction and analytic methods, all but 2 of the 230 tested vials were found to be free of surface drug contamination. Pharmacy leaders need to take an active role in promoting the need for clean HD vials. Manufacturers should be required to provide their clients with data derived from externally validated analytic studies, reporting the level of HD contamination on the exterior of their vial products. PMID:24958942
NASA Technical Reports Server (NTRS)
2001-01-01
Advanced Fuel Research, Inc. (AFR) developed a new sol-gel material coating for sample vials to be used in surface-enhanced Raman (SER) spectroscopy. In the fields of biomedical and forensic science, the coated vials are used to identify physiological chemicals present in blood and urine. The vials are used in the pharmaceutical industry in the area of drug development and discovery. In the drug enforcement field, using the vials helps with detection of trace amounts of drugs on surfaces. The SER vials will also help to identify contaminants in water sources, such as various inorganics and pesticides. The new vials have advantages over other SER materials. Former products required that samples be pre-mixed or dissolved into specific solvents or reagents. The SER vials do not have these limitations, and measurements can be performed using any solvent. Furthermore, the signal appears in less than one second. The sol-gel material will stay active for at least one year and the vials are compatible with any Raman spectrometer. Most importantly, the SER activity can be duplicated from vial-to-vial, allowing for reproducible results.
Parrish, Nicole; Osterhout, Gerard; Dionne, Kim; Sweeney, Amy; Kwiatkowski, Nicole; Carroll, Karen; Jost, Kenneth C.; Dick, James
2007-01-01
Multidrug-resistant (MDR) Mycobacterium tuberculosis and extrensively drug-resistant (XDR) M. tuberculosis are emerging public health threats whose threats are compounded by the fact that current techniques for testing the susceptibility of M. tuberculosis require several days to weeks to complete. We investigated the use of high-performance liquid chromatography (HPLC)-based quantitation of mycolic acids as a means of rapidly determining drug resistance and susceptibility in M. tuberculosis. Standard susceptibility testing and determination of the MICs of drug-susceptible (n = 26) and drug-resistant M. tuberculosis strains, including MDR M. tuberculosis strains (n = 34), were performed by using the Bactec radiometric growth system as the reference method. The HPLC-based susceptibilities of the current first-line drugs, isoniazid (INH), rifampin (RIF), ethambutol (EMB), and pyrazinamide (PZA), were determined. The vials were incubated for 72 h, and aliquots were removed for HPLC analysis by using the Sherlock mycobacterial identification system. HPLC quantitation of total mycolic acid peaks (TMAPs) was performed with treated and untreated cultures. At 72 h, the levels of agreement of the HPLC method with the reference method were 99.5% for INH, EMB, and PZA and 98.7% for RIF. The inter- and intra-assay reproducibilities varied by drug, with an average precision of 13.4%. In summary, quantitation of TMAPs is a rapid, sensitive, and accurate method for antibiotic susceptibility testing of all first-line drugs currently used against M. tuberculosis and offers the potential of providing susceptibility testing results within hours, rather than days or weeks, for clinical M. tuberculosis isolates. PMID:17913928
The effect of cool water pack preparation on vaccine vial temperatures in refrigerators.
Goldwood, Geneva; Diesburg, Steven
2018-01-02
Cool water packs are a useful alternative to ice packs for preventing unintentional freezing of vaccines during outreach in some situations. Current guidelines recommend the use of a separate refrigerator for cooling water packs from ambient temperatures to prevent possible heat degradation of adjacent vaccine vials. To investigate whether this additional equipment is necessary, we measured the temperatures that vaccine vials were exposed to when warm water packs were placed next to vials in a refrigerator. We then calculated the effect of repeated vial exposure to those temperatures on vaccine vial monitor status to estimate the impact to the vaccine. Vials were tested in a variety of configurations, varying the number and locations of vials and water packs in the refrigerator. The calculated average percentage life lost during a month of repeated warming ranged from 20.0% to 30.3% for a category 2 (least stable) vaccine vial monitor and from 3.8% to 6.0% for a category 7 (moderate stability) vaccine vial monitor, compared to 17.0% for category 2 vaccine vial monitors and 3.1% for category 7 vaccine vial monitors at a constant 5 °C. The number of vials, number of water packs, and locations of each impacted vial warming and therefore percentage life lost, but the vaccine vial monitor category had a higher impact on the average percentage life lost than any of the other parameters. The results suggest that damage to vaccines from repeated warming over the course of a month is not certain and that cooling water packs in a refrigerator where vaccines are being stored may be a useful practice if safe procedures are established. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Budget impact analysis of insulin therapies and associated delivery systems.
Lee, Lauren J; Smolen, Lee J; Klein, Timothy M; Foster, Shonda A; Whiteman, Doug; Jorgenson, James A; Hultgren, Steve
2012-06-01
A budget impact analysis of insulin therapies and associated delivery systems is presented. Based on inputted procurement totals, per-item costs (based on 2011 average wholesale price), insulin distribution system (floor stock or individual patient supply), waste, and treatment protocols for a specified time frame, the budget impact model approximated the number of patients treated with subcutaneous insulin, costs, utilization, waste, and injection mechanism (pen safety needle or syringe) costs. To calculate net changes, results of one-year 3-mL vial use were subtracted from one-year 10-mL vial or 3-mL pen use. Switching from a 10-mL vial to a 3-mL vial was associated with reductions in both costs and waste. The net reductions in costs and waste ranged from $15,482 and 120,000 IU, respectively, for floor-stock 10-mL vial to floor-stock 3-mL vial conversion to $871,548 and 6,750,000 IU, respectively, for individual patient supply 10-mL vial to floor-stock 3-mL vial conversion. Switching from floor-stock 10-mL vials to individual patient supply 3-mL vials increased costs and waste by $164,659 and 1,275,000 IU, respectively. Converting from individual patient supply 3-mL pens to individual patient supply 3-mL vials reduced costs by $117,236 but did not decrease waste. A budget impact analysis of the conversion of either 10-mL insulin vials or 3-mL insulin pens to 3-mL insulin vials found reductions in both cost and waste, except when converting from floor-stock 10-mL vials to individual patient supply 3-mL vials.
Grant, I R; Ball, H J; Rowe, M T
1998-02-01
The efficacy of high-temperature, short-time (HTST) pasteurization (72 degrees C/15 s) when low numbers (< or = 10(3) cfu ml-1) of Mycobacterium paratuberculosis are present in milk was investigated. Raw cows' milk spiked with Myco. paratuberculosis (10(3) cfu ml-1, 10(2) cfu ml-1, 10 cfu ml-1, and 10 cfu 50 ml-1) was subjected to HTST pasteurization using laboratory pasteurizing units. Ten bovine strains of Myco. paratuberculosis were tested in triplicate. Culture in BACTEC Middlebrook 12B radiometric medium detected acid-fast survivors in 14.8% and 10% of HTST-pasteurized milk samples at the 10(3) and 10(2) cfu ml-1 inoculum levels, respectively, whereas conventional culture on Herrold's egg yolk medium containing mycobactin J detected acid-fast survivors in only 3.7% and 6.7% of the same milk samples. IS900-based PCR confirmed that these acid-fast survivors were Myco. paratuberculosis. No viable Myco. paratuberculosis were isolated from HTST-pasteurized milk initially containing either 10 cfu ml-1 or 10 cfu 50 ml-1.
Stability of reconstituted parecoxib for injection with commonly used diluents.
Crane, I M; Mulhern, M G; Nema, S
2003-10-01
The purpose of this study was to evaluate the effect of diluent type, storage conditions and the nature of package on the stability of reconstituted Parecoxib sodium for injection (PSI). Parecoxib sodium for injection is a lyophilized product for single use. It is intended for the management of acute pain. Six diluent types were initially evaluated for physical compatibility with PSI. Reconstituted PSI was visually inspected at 8, 24 and 48 h after reconstitution with 0.9% sodium chloride injection (NS), lactated ringers injection (LR), bacteriostatic 0.9% NaCl injection (BNS), lactated ringers and 5% dextrose injection (LR + D5W), 5% dextrose injection (D5W), and 5% dextrose + 0.45% NaCl injection (D5W + 1/2NS). Reconstituted PSI, stored in glass vials and glass or plastic syringes at 5 degrees and 25 degrees C, under 500 lx light intensity for 48 h or subjected to freeze-thaw cycles, were tested for chemical stability by high-performance liquid chromatography (HPLC). The PSI reconstituted with NS, BNS, D5W, and D5W + 1/2NS met visual acceptance criteria and showed almost no (<0.5% total) degradation under all storage conditions. No significant differences were seen between storage in glass vials or polypropylene/glass syringes. PSI reconstituted with LR and LR + D5W showed visual precipitation in many vials which was confirmed by the decrease in the HPLC assay values at all time points. The needlelike crystals (precipitate), analyzed by Infrared Spectroscopy and Scanning Electron Microscopy-Energy Dispersive Spectrometry (SEM-EDS) analyses, were identified as the free acid form of the active drug. PSI is stable after reconstitution, with NS, BNS, D5W, and D5W + 1/2NS, when stored at room temperature in glass vials or glass/plastic syringes for up to 48 h* LR and LR + D5W are not recommended for reconstitution because of crystallization of the drug (free acid).
Dissolution actuated sample container
Nance, Thomas A.; McCoy, Frank T.
2013-03-26
A sample collection vial and process of using a vial is provided. The sample collection vial has an opening secured by a dissolvable plug. When dissolved, liquids may enter into the interior of the collection vial passing along one or more edges of a dissolvable blocking member. As the blocking member is dissolved, a spring actuated closure is directed towards the opening of the vial which, when engaged, secures the vial contents against loss or contamination.
INTEGRITY OF VOA-VIAL SEALS | Science Inventory | US ...
Preservation of soil samples for the analysis of volatile organic compounds (VOCs) requires both the inhibition of VOC degradation and the restriction of vapor movement in or out of the sample container. Clear, 40,mL glass VOA vials manufactured by the four major U.S. glass manufacturers were tested for seal integrity. Visual inspection revealed a variety of imperfections ranging from small indentations, bumps, and scratches on vial threads or lips, through obvious defects, such as large indentations or grooves in the vial lips and chipped or broken glass. The aluminum plate vacuum test proved to be unreliable in identifying potentially leaky vials. The septa-seal vacuum test was conducted twice on the 80 selected vials.Mean VOC concentrations after 14 days storage generally were within +- 20% of the known concentration with a majority of the concentrations within +- 15% of their known values. There were no statistically significant differences in VOC concentrations between vials in the potentially leaky and control group for any of the manufacturers. Only 1 vial lost VOCs and that was due to a large chip in the vial's lip and neck. These findings indicate that the silicone septa are flexible enough to overcome most vial imperfections and form a complete seal against VOC loss. A careful inspection of the VOA vials prior to use to remove any vials with large and obvious imperfections should be sufficient to screen out vials that are subject to VOC losses.
Fleury-Souverain, Sandrine; Nussbaumer, Susanne; Mattiuzzo, Marc; Bonnabry, Pascal
2014-04-01
The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.
Anvarinejad, Mojtaba; Pouladfar, Gholam Reza; Pourabbas, Bahman; Amin Shahidi, Maneli; Rafaatpour, Noroddin; Dehyadegari, Mohammad Ali; Abbasi, Pejman; Mardaneh, Jalal
2016-04-01
Human salmonellosis continues to be a major international problem, in terms of both morbidity and economic losses. The antibiotic resistance of Salmonella is an increasing public health emergency, since infections from resistant bacteria are more difficult and costly to treat. The aims of the present study were to investigate the isolation of Salmonella spp. with the BACTEC automated system from blood samples during 2008 - 2014 in southern Iran (Shiraz). Detection of subspecies, biogrouping, and antimicrobial susceptibility testing by the disc diffusion and agar dilution methods were performed. A total of 19 Salmonella spp. were consecutively isolated using BACTEC from blood samples of patients between 2008 and 2014 in Shiraz, Iran. The isolates were identified as Salmonella, based on biochemical tests embedded in the API-20E system. In order to characterize the biogroups and subspecies, biochemical testing was performed. Susceptibility testing (disc diffusion and agar dilution) and extended-spectrum β-lactamase (ESBL) detection were performed according to the clinical and laboratory standards institute (CLSI) guidelines. Of the total 19 Salmonella spp. isolates recovered by the BACTEC automated system, all belonged to the Salmonella enterica subsp. houtenae. Five isolates (26.5%) were resistant to azithromycin. Six (31.5%) isolates with the disc diffusion method and five (26.3%) with the agar dilution method displayed resistance to nalidixic acid (minimum inhibitory concentration [MIC] > 32 μg/mL). All nalidixic acid-resistant isolates were also ciprofloxacin-sensitive. All isolates were ESBL-negative. Twenty-one percent of isolates were found to be resistant to chloramphenicol (MIC ≥ 32 μg/mL), and 16% were resistant to ampicillin (MIC ≥ 32 μg/mL). The results indicate that multidrug-resistant (MDR) strains of Salmonella are increasing in number, and fewer antibiotics may be useful for treating S. enterica infections. Routine investigation and reporting of antibiotic MICs in patients presenting with Salmonella infections is suggested.
Landi, S; Held, H R
1965-01-01
Chinosol (8-quinolinol sulfate), which is employed as an antimicrobial agent in tuberculin PPD solutions used for the Mantoux test, is known to disappear from these solutions after storage. It has been established that the loss of this preservative from tuberculin solutions dispensed in glass vials is caused by the rubber stoppers used to seal the vials. All the rubber stoppers tested absorbed Chinosol very readily.The nature of the binding of Chinosol by a rubber stopper is both chemical (irreversible) and physical (reversible). The capacity to bind Chinosol chemically was determined for 12 types of rubber stopper, and was found to vary from 0 to more than 25% by weight of the stopper. This phenomenon can be attributed mainly to metal ingredients in the stopper. The capacity of stoppers to bind Chinosol physically is expressed quantitatively by a partition coefficient. This was determined for 7 types of rubber stopper and found to be high when compared with the partition coefficients of other preservatives.We have shown that all stoppers presaturated in Chinosol can be equilibrated against a buffered solution containing 0.01% Chinosol. Equilibrated silicone, white, and red oxiglazed stoppers can be used satisfactorily for sealing multi-dose vials of tuberculin PPD containing 0.01% Chinosol.
Landi, S.; Held, H. R.
1965-01-01
Chinosol (8-quinolinol sulfate), which is employed as an antimicrobial agent in tuberculin PPD solutions used for the Mantoux test, is known to disappear from these solutions after storage. It has been established that the loss of this preservative from tuberculin solutions dispensed in glass vials is caused by the rubber stoppers used to seal the vials. All the rubber stoppers tested absorbed Chinosol very readily. The nature of the binding of Chinosol by a rubber stopper is both chemical (irreversible) and physical (reversible). The capacity to bind Chinosol chemically was determined for 12 types of rubber stopper, and was found to vary from 0 to more than 25% by weight of the stopper. This phenomenon can be attributed mainly to metal ingredients in the stopper. The capacity of stoppers to bind Chinosol physically is expressed quantitatively by a partition coefficient. This was determined for 7 types of rubber stopper and found to be high when compared with the partition coefficients of other preservatives. We have shown that all stoppers presaturated in Chinosol can be equilibrated against a buffered solution containing 0.01% Chinosol. Equilibrated silicone, white, and red oxiglazed stoppers can be used satisfactorily for sealing multi-dose vials of tuberculin PPD containing 0.01% Chinosol. ImagesFIG. 2 PMID:5294923
Idelevich, Evgeny A; Grünastel, Barbara; Becker, Karsten
2017-01-01
Candida sepsis is a life-threatening condition with increasing prevalence. In this study, direct blood culturing on solid medium using a lysis-centrifugation procedure enabled successful Candida species identification by matrix-assisted laser desorption-ionization time of flight mass spectrometry on average 3.8 h (Sabouraud agar) or 7.4 h (chocolate agar) before the positivity signal for control samples in Bactec mycosis-IC/F or Bactec Plus aerobic/F bottles, respectively. Direct culturing on solid medium accelerated candidemia diagnostics compared to that with automated broth-based systems. Copyright © 2016 American Society for Microbiology.
High or low- a trial of low dose anti snake venom in the treatment of poisonous snakebites.
Cherian, A M; Girish, T S; Jagannati, Manjeera; Lakshmi, M
2013-06-01
To demonstrate that use of lower doses of anti-snake venom is as effective as high doses and is associated with less complications and lower mortality especially in the wake of rising cost of medical treatment, the people most affected by snakebites being the poor farmers. A prospective descriptive study consisting of 54 snakebite patients fulfilling the inclusion criteria who were admitted to Bangalore Baptist Hospital, Bengaluru, between November 2006 and November 2008 and were treated with a low dose ASV regime. The patients were initially given 2 vials of ASV followed later with 1 vial at a time according to clotting time. Any other supportive measures were undertaken as necessary. In this study the average dose of ASV required was only 6.70 +/- 3.24 vials. The complications--12.9% patients had ARF, and another 12.9% patients had neuropraralysis severe enough to require ventilatory support. There were 2 deaths (mortality of 3.7%) in the study. Low dose ASV regime in poisonous snakebites along with supportive treatment as necessary is as good as high dose regime, and has lesser adverse effects while reducing the cost of treatment too. Hence low dose regime can be used with beneficial results in poisonous snakebites.
21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).
Code of Federal Regulations, 2011 CFR
2011-04-01
... accessories, such as vials, specimen containers, medium, drapes, etc. The device is used at 16-18 weeks... when used to assess fetal maturity. (b) Classification. Class I (general controls). The device is...
21 CFR 884.1550 - Amniotic fluid sampler (amniocentesis tray).
Code of Federal Regulations, 2010 CFR
2010-04-01
... accessories, such as vials, specimen containers, medium, drapes, etc. The device is used at 16-18 weeks... when used to assess fetal maturity. (b) Classification. Class I (general controls). The device is...
Validation of the shake test for detecting freeze damage to adsorbed vaccines.
Kartoglu, Umit; Ozgüler, Nejat Kenan; Wolfson, Lara J; Kurzatkowski, Wiesław
2010-08-01
To determine the validity of the shake test for detecting freeze damage in aluminium-based, adsorbed, freeze-sensitive vaccines. A double-blind crossover design was used to compare the performance of the shake test conducted by trained health-care workers (HCWs) with that of phase contrast microscopy as a "gold standard". A total of 475 vials of 8 different types of World Health Organization prequalified freeze-sensitive vaccines from 10 different manufacturers were used. Vaccines were kept at 5 degrees C. Selected numbers of vials from each type were then exposed to -25 degrees C and -2 degrees C for 24-hour periods. There was complete concordance between HCWs and phase-contrast microscopy in identifying freeze-damaged vials and non-frozen samples. Non-frozen samples showed a fine-grain structure under phase contrast microscopy, but freeze-damaged samples showed large conglomerates of massed precipitates with amorphous, crystalline, solid and needle-like structures. Particles in the non-frozen samples measured from 1 microm (vaccines against diphtheria-tetanus-pertussis; Haemophilus influenzae type b; hepatitis B; diphtheria-tetanus-pertussis-hepatitis B) to 20 microm (diphtheria and tetanus vaccines, alone or in combination). By contrast, aggregates in the freeze-damaged samples measured up to 700 microm (diphtheria-tetanus-pertussis) and 350 microm on average. The shake test had 100% sensitivity, 100% specificity and 100% positive predictive value in this study, which confirms its validity for detecting freeze damage to aluminium-based freeze-sensitive vaccines.
Fujimori, Kiyoshi; Lee, Hans; Sloey, Christopher; Ricci, Margaret S; Wen, Zai-Qing; Phillips, Joseph; Nashed-Samuel, Yasser
2016-01-01
Certain types of glass vials used as primary containers for liquid formulations of biopharmaceutical drug products have been observed with delamination that produced small glass like flakes termed lamellae under certain conditions during storage. The cause of this delamination is in part related to the glass surface defects, which renders the vials susceptible to flaking, and lamellae are formed during the high-temperature melting and annealing used for vial fabrication and shaping. The current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. Four alternative techniques with improved throughput, convenience, and/or comprehension were examined by subjecting seven lots of vials to analysis by all techniques. The first three new techniques of conductivity, flame photometry, and inductively coupled plasma mass spectrometry measured the same sample pools as acid titration. All three showed good correlation with alkalinity: conductivity (R(2) = 0.9951), flame photometry sodium (R(2) = 0.9895), and several elements by inductively coupled plasma mass spectrometry [(sodium (R(2) = 0.9869), boron (R(2) = 0.9796), silicon (R(2) = 0.9426), total (R(2) = 0.9639)]. The fourth technique processed the vials under conditions that promote delamination, termed accelerated lamellae formation, and then inspected those vials visually for lamellae. The visual inspection results without the lot with different processing condition correlated well with alkalinity (R(2) = 0.9474). Due to vial processing differences affecting alkalinity measurements and delamination propensity differently, the ratio of silicon and sodium measurements from inductively coupled plasma mass spectrometry was the most informative technique to assess overall vial quality and vial propensity for lamellae formation. The other techniques of conductivity, flame photometry, and accelerated lamellae formation condition may still be suitable for routine screening of vial lots produced under consistent processes. Recently, delamination that produced small glass like flakes termed lamellae has been observed in glass vials that are commonly used as primary containers for pharmaceutical drug products under certain conditions during storage. The main cause of these lamellae was the quality of the glass itself related to the manufacturing process. Current European Pharmacopoeia method to assess glass vial quality utilizes acid titration of vial extract pools to determine hydrolytic resistance or alkalinity. As alternative to the European Pharmacopoeia method, four other techniques were assessed. Three new techniques of conductivity, flame photometry, and inductively coupled plasma mass spectrometry measured the vial extract pool as acid titration to quantify quality, and they demonstrated good correlation with original alkalinity. The fourth technique processed the vials under conditions that promote delamination, termed accelerated lamellae formation, and the vials were then inspected visually for lamellae. The accelerated lamellae formation technique also showed good correlation with alkalinity. Of the new four techniques, inductively coupled plasma mass spectrometry was the most informative technique to assess overall vial quality even with differences in processing between vial lots. Other three techniques were still suitable for routine screening of vial lots produced under consistent processes. © PDA, Inc. 2016.
Prince, Deidré; Rossouw, Daniel; Davids, Claudia; Rubow, Sietske
2017-12-01
This study was aimed to develop single vial 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-peptide kits to be used with fractionated eluates from a SnO 2 -based 68 Ge/ 68 Ga generator. Kits were formulated with 35 μg DOTA-Tyr 3 -Thre 8 -octreotide, DOTA-[Tyr 3 ]-octreotide and DOTA-[NaI 3 ]-octreotide (DOTATATE, DOTATOC and DOTANOC) and sodium acetate powder, vacuum-dried and stored at -20 °C for up to 12 months. Labelling of the kits was carried out with 2 ml 68 Ga eluate. Comparative labelling was carried out using aqueous DOTA-peptide stock solutions kept frozen at -20 °C for up to 12 months. The quality of the kits was found to be suitable over a 1-year storage period (pH, sterility, endotoxin content, radiolabelling efficiency and radiochemical yields of 68 Ga-labelled DOTA-peptides). Radiochemical yields ranged from 73 to 83 %, while those obtained from stock solutions from 64 to 79 %. No significant decline in kit labelling yields was observed over a 12-month storage period. The single vial kit formulations met the quality release specifications for human administration and appear to be highly advantageous over using peptide stock solutions in terms of stability and user-friendliness.
Burton, Deron C.; Bigogo, Godfrey M.; Audi, Allan O.; Williamson, John; Munge, Kenneth; Wafula, Jackline; Ouma, Dominic; Khagayi, Sammy; Mugoya, Isaac; Mburu, James; Muema, Shadrack; Bauni, Evasius; Bwanaali, Tahreni; Feikin, Daniel R.; Ochieng, Peter M.; Mogeni, Ondari D.; Otieno, George A.; Olack, Beatrice; Kamau, Tatu; Van Dyke, Melissa K.; Chen, Robert; Farrington, Paddy; Montgomery, Joel M.; Breiman, Robert F.; Scott, J. Anthony G.; Laserson, Kayla F.
2015-01-01
There is a theoretical risk of adverse events following immunization with a preservative-free, 2-dose vial formulation of 10-valent-pneumococcal conjugate vaccine (PCV10). We set out to measure this risk. Four population-based surveillance sites in Kenya (total annual birth cohort of 11,500 infants) were used to conduct a 2-year post-introduction vaccine safety study of PCV10. Injection-site abscesses occurring within 7 days following vaccine administration were clinically diagnosed in all study sites (passive facility-based surveillance) and, also, detected by caregiver-reported symptoms of swelling plus discharge in two sites (active household-based surveillance). Abscess risk was expressed as the number of abscesses per 100,000 injections and was compared for the second vs first vial dose of PCV10 and for PCV10 vs pentavalent vaccine (comparator). A total of 58,288 PCV10 injections were recorded, including 24,054 and 19,702 identified as first and second vial doses, respectively (14,532 unknown vial dose). The risk ratio for abscess following injection with the second (41 per 100,000) vs first (33 per 100,000) vial dose of PCV10 was 1.22 (95% confidence interval [CI] 0.37–4.06). The comparator vaccine was changed from a 2-dose to 10-dose presentation midway through the study. The matched odds ratios for abscess following PCV10 were 1.00 (95% CI 0.12–8.56) and 0.27 (95% CI 0.14–0.54) when compared to the 2-dose and 10-dose pentavalent vaccine presentations, respectively. In Kenya immunization with PCV10 was not associated with an increased risk of injection site abscess, providing confidence that the vaccine may be safely used in Africa. The relatively higher risk of abscess following the 10-dose presentation of pentavalent vaccine merits further study. PMID:26509274
Burton, Deron C; Bigogo, Godfrey M; Audi, Allan O; Williamson, John; Munge, Kenneth; Wafula, Jackline; Ouma, Dominic; Khagayi, Sammy; Mugoya, Isaac; Mburu, James; Muema, Shadrack; Bauni, Evasius; Bwanaali, Tahreni; Feikin, Daniel R; Ochieng, Peter M; Mogeni, Ondari D; Otieno, George A; Olack, Beatrice; Kamau, Tatu; Van Dyke, Melissa K; Chen, Robert; Farrington, Paddy; Montgomery, Joel M; Breiman, Robert F; Scott, J Anthony G; Laserson, Kayla F
2015-01-01
There is a theoretical risk of adverse events following immunization with a preservative-free, 2-dose vial formulation of 10-valent-pneumococcal conjugate vaccine (PCV10). We set out to measure this risk. Four population-based surveillance sites in Kenya (total annual birth cohort of 11,500 infants) were used to conduct a 2-year post-introduction vaccine safety study of PCV10. Injection-site abscesses occurring within 7 days following vaccine administration were clinically diagnosed in all study sites (passive facility-based surveillance) and, also, detected by caregiver-reported symptoms of swelling plus discharge in two sites (active household-based surveillance). Abscess risk was expressed as the number of abscesses per 100,000 injections and was compared for the second vs first vial dose of PCV10 and for PCV10 vs pentavalent vaccine (comparator). A total of 58,288 PCV10 injections were recorded, including 24,054 and 19,702 identified as first and second vial doses, respectively (14,532 unknown vial dose). The risk ratio for abscess following injection with the second (41 per 100,000) vs first (33 per 100,000) vial dose of PCV10 was 1.22 (95% confidence interval [CI] 0.37-4.06). The comparator vaccine was changed from a 2-dose to 10-dose presentation midway through the study. The matched odds ratios for abscess following PCV10 were 1.00 (95% CI 0.12-8.56) and 0.27 (95% CI 0.14-0.54) when compared to the 2-dose and 10-dose pentavalent vaccine presentations, respectively. In Kenya immunization with PCV10 was not associated with an increased risk of injection site abscess, providing confidence that the vaccine may be safely used in Africa. The relatively higher risk of abscess following the 10-dose presentation of pentavalent vaccine merits further study.
Hibler, Susanne; Wagner, Christophe; Gieseler, Henning
2012-01-01
In a previous study, heat transfer coefficients of different 10 mL tubing and molded vials were determined gravimetrically via sublimation tests with pure water. Contrary to "conventional wisdom", only small differences in K(v) values between tubing and molded vials were found in the pressure range relevant for pharmaceutical freeze-drying. In order to investigate the impact of these relatively small differences on the primary drying time of an actual product, freeze-drying experiments with 5% gentamicin sulfate solution as a model system were performed at 68, 100 and 200 mTorr. The primary drying times of the API in recently developed molded (EasyLyo™), tubing (TopLyo™) and polymer vials (TopPac™) were compared. At 68 and 100 mTorr the primary drying time of the drug in the glass vials only differed by 3% to 4%, while the polymer vial took around 9% longer. At 200 mTorr, the API in the EasyLyo™ vials dried approximately 15% faster compared to the other vial types. The present study suggest that molded vials that have been modified in design to have better heat transfer properties can achieve drying times comparable to tubing vials.
"Product on Stopper" in a Lyophilized Drug Product: Cosmetic Defect or a Product Quality Concern?
Mehta, Shyam B; Roy, Shouvik; Yang, Han-Chang Cathy
2018-06-01
During manufacturing of a lyophilized drug product, operator errors in product handling during loading of product filled vials onto the lyophilizer can lead to a seemingly cosmetic defect which can impact certain critical quality attributes of finished product. In this study, filling of a formulated monoclonal antibody in vials was performed using a peristaltic pump filling unit, and subsequently, the product was lyophilized. After lyophilization, upon visual inspection, around 40% of vials had cosmetic defect with residual product around stopper of the vial and were categorized as "product on stopper" vials, whereas remaining 60% vials with no cosmetic defect were called "acceptable vials." Both groups of vials from 1 single batch were tested for critical quality attributes including protein concentration (ultraviolet absorbance at 280), residual moisture (Karl Fischer), sterility (membrane filtration), and container closure integrity (CCI) (blue dye ingress). Analysis of protein quality attributes such as aggregation, protein concentration, residual moisture showed no significant difference between vials with "product on stopper" and "acceptable vials." However, CCI of the "product on stopper" vials was compromised due to the presence of product around stopper of the vial. The results from this case study demonstrate the following 2 important findings: (1) that a seemingly cosmetic defect may impact product quality, compromising the integrity of the product and (2) that CCI test method can be used as an orthogonal method to sterility testing to evaluate sterility assurance of the product. The corrective action proposed to mitigate this defect is use of a larger sized vial that can potentially minimize this defect that arises because of product handling errors. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Sanz, F; Soledad Cuétara, M; del Palacio, A; Campbell, C K; Johnson, L; Urruzunu, P; Pía Roiz, M
1993-11-01
F. solani fungemia is unusual. Patients at risk are immunosuppressed, have underlying malignancy or severe debilitating diseases. We report two cases of F. solani fungemia in two non neutropenic patients who had been treated with wide-spectrum antibiotics an/or systemic corticosteroids, parenteral nutrition and intravenous lines. Bactec NR-860 (Becton-Dickinson) system was used, and growth was detected in aerobic conditions (between 3-7 days of incubation). Removal of the catheters with or without i.v. amphotericin B were used successfully. The spectrum of Fusarium sp. fungemia is discussed. Current available antifungal therapy is also reviewed.
How Vial Geometry Variability Influences Heat Transfer and Product Temperature During Freeze-Drying.
Scutellà, Bernadette; Passot, Stéphanie; Bourlés, Erwan; Fonseca, Fernanda; Tréléa, Ioan Cristian
2017-03-01
Vial design features can play a significant role in heat transfer between the shelf and the product and, consequently, in the final quality of the freeze-dried product. Our objective was to investigate the impact of the variability of some geometrical dimensions of a set of tubing vials commonly used for pharmaceuticals production on the distribution of the vial heat transfer coefficients (K v ) and its potential consequence on product temperature. Sublimation tests were carried out using pure water and 8 combinations of chamber pressure (4-50 Pa) and shelf temperature (-40°C and 0°C) in 2 freeze-dryers. K v values were individually determined for 100 vials located in the center of the shelf. Vial bottom curvature depth and contact area between the vial and the shelf were carefully measured for 120 vials and these data were used to calculate K v distribution due to variability in vial geometry. At low pressures commonly used for sensitive products (below 10 Pa), the vial-shelf contact area appeared crucial for explaining K v heterogeneity and was found to generate, in our study, a product temperature distribution of approximately 2°C during sublimation. Our approach provides quantitative guidelines for defining vial geometry tolerance specifications and product temperature safety margins. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Rambhatla, Shailaja; Pikal, Michael J
2003-01-01
The aim of this study is to determine whether radiation heat transfer is responsible for the position dependence of heat transfer known as the edge vial effect. Freeze drying was performed on a laboratory-scale freeze dryer using pure water with vials that were fully stoppered but had precision cut metal tubes inserted in them to ensure uniformity in resistance to vapor flow. Sublimation rates were determined gravimetrically. Vials were sputter-coated with gold and placed at selected positions on the shelf. Average sublimation rates were determined for vials located at the front, side, and center of an array of vials. Sublimation rates were also determined with and without the use of aluminum foil as a radiation shield. The effect of the guardrail material and its contribution to the edge vial effect by conduction heat transfer was studied by replacing the stainless steel band with a low-thermal conductivity material (styrofoam). The emissivities (epsilon) of relevant surfaces were measured using an infrared thermometer. Sublimation rate experiments were also conducted with vials suspended off the shelf to study the role of convection heat transfer. It was found that sublimation rates were significantly higher for vials located in the front compared to vials in the center. Additional radiation shields in the form of aluminum foil on the inside door resulted in a decrease in sublimation rates for the front vials and to a lesser extent, the center vials. There was a significant decrease in sublimation rate for gold-coated vials (epsilon approximately 0.4) placed at the front of an array when compared to that of clear vials (epsilon approximately 0.9). In the case of experiments with vials suspended off the shelf, the heat transfer coefficient was found to be independent of chamber pressure, indicating that pure convection plays no significant role in heat transfer. Higher sublimation rates were observed when the steel band was used instead of Styrofoam while the highest sublimation rates were obtained in the absence of the guardrail, indicating that the metal band can act as a thermal shield but also transmits some heat from the shelf via conduction and radiation. Atypical radiation heat transfer is responsible for higher sublimation rates for vials located at the front and side of an array. However, the guardrail contributes a little to heat transfer by conduction.
Acid-fast bacilli culture positivity and drug resistance in abdominal tuberculosis in Mumbai, India.
Samant, Hrishikesh; Desai, Devendra; Abraham, Philip; Joshi, Anand; Gupta, Tarun; Rodrigues, Camilla; George, Siji
2014-09-01
Culture positivity for Mycobacterium tuberculosis complex (MTB) in abdominal tuberculosis (TB) using Lowenstein Jensen medium and Bactec system varies from 25 % to 36 %. Data on the prevalence of drug resistance in primary abdominal TB is scant. Our aim was to study the acid-fast bacilli (AFB) culture positivity rate in primary abdominal TB using Bactec Mycobacterial Growth Indicator Tubes (MGIT) system and the prevalence of drug resistance in these patients. Records of patients with abdominal TB (diagnosed on clinical features, endoscopy, histology, microbiology) seen during the period 2008 to 2013 were retrieved from the Gastroenterology and Microbiology departments. Patients with extra-abdominal TB (five pulmonary, two nodal), adnexal (one), and HIV (one) were excluded from analysis. Of 61 patients, 31 (50.8 %) had a positive AFB culture. In the 30 culture-negative patients, histology showed non-caseating granulomas in 25 patients. Drug sensitivity pattern was analyzed in 18 patients; resistance was detected in eight (14.3 % of all patients and 44.4 % of patients in whom drug sensitivity was done) including three (5.4 % of all subjects and 16.6 % in whom drug sensitivity was available) who were multidrug-resistant. The rate of AFB culture positivity in primary abdominal TB was 50.8 % using Bactec MGIT. Likelihood of drug resistance was seen in 14.3 %, of whom 5.4 % were multidrug-resistant.
NASA Technical Reports Server (NTRS)
Hailey, M.; Bayuse, T.
2010-01-01
Fluid Isolation in the medication vial: Air/ fluid isolation maneuvers were used to move the medication to the septum end of vial. This isolation may be achieved in multiple ways based on the experience of the astronaut with fluid management in microgravity. If vial adaptors/blunt cannula or syringe assembly is inserted into the to vial before fluid isolation commences, the stability of this assembly should be considered in an effort to limit the risk of "slinging off" of the vial during isolation. Alternatively, fluid isolation can be performed prior to attaching the syringe/vial adaptor assembly. Terrestrial practices for medication withdrawal from a nonvented vial require injection of an equivalent amount of air as the expected medication volume prior to withdrawing liquid. In microgravity, this action is still valid, however the injection of additional air into the vial creates a multitude of micro bubbles and increases the volume of medication mixed with air that then must be withdrawn to achieve the desired drug volume in syringe. This practice is more likely to be required when using vials >30ml in size and injection volumes >10mL. It is felt that based on the microgravity flight, the practice of air injection is more of a hindrance than help.
Zuleger, Brigitte; Werner, Uwe; Kort, Alexander; Glowienka, Rene; Wehnes, Engelbert; Duncan, Derek
2012-01-01
It was recently found that after storage of a live viral vaccine at -80 °C in glass vials closed with rubber stoppers, a phenomenon was revealed which had not been observed before with other viral products stored at -20 °C: overpressure in the vials. As this phenomenon poses a serious safety problem for medical personnel as well as for the product itself, an investigation was initiated to identify the root cause of the overpressure. After exclusion of possible root causes (differences in air temperature or atmospheric air pressure during filling and quality control testing, outgassing from the formulation buffer) the remaining hypothesis involved a possible container closure integrity issue at low temperature. The glass transition temperatures (T(g)) of many rubber stopper formulations are in the range -55 to -70 °C. At storage temperatures below T(g), the rubber stopper loses its elastic properties and there is a risk that the seal integrity of the vial could be compromised. Loss of seal integrity of the vials near storage temperatures of -80 °C would result in an ingress of cold dense gas into the vial headspace. After removal of the vials from storage at -80 °C, the rubber stoppers could regain their elastic properties and the vials would quickly reseal, thereby trapping the ingressed gas, which leads to overpressure in the vial headspace. Nondestructive laser-based headspace analysis was used to investigate the maintenance of container closure integrity as a function of the filling and capping/crimping process, storage and transport conditions, and vial/stopper designs. This analytical method is based on frequency modulation spectroscopy (FMS) and can be used for noninvasive headspace measurements of headspace pressure and headspace gas composition. Changes in the vial headspace composition and/or pressure are a clear marker for vials that have lost container closure integrity. After storage of a live viral vaccine at -80 °C in glass vials closed with rubber stoppers, overpressure in some of the vials was observed, posing a serious safety problem for medical personnel as well as for the product. A working hypothesis to explain this phenomenon involved a possible container closure integrity issue at these low temperatures. The glass transition temperatures (T(g)) of many rubber stopper formulations are in the range -55 to -70 °C. At storage temperatures below T(g), the rubber stopper loses its elastic properties, resulting in compromised seal integrity of the vial and ingress of cold dense gas into the vial headspace. Upon thawing, the rubber stoppers regain their elastic properties and the vials quickly reseal, thereby trapping the ingressed gas, which leads to overpressure in the vial headspace. Nondestructive, laser-based headspace analysis, which is able to detect changes in headspace pressure and gas composition, was used to investigate the maintenance of container closure integrity. Changes in the vial headspace composition and/or pressure are a clear marker for vials that have lost container closure integrity.
Is insulin diluted when stored in water?
Plager, Phillip; Nurie, Kadiro; Omann, Trevor; Moran, Antoinette; Piloya, Thereza; Bahendeka, Silver; Sunni, Muna
2017-05-01
Insulin storage is a challenge in resource-poor countries. In Uganda, patients were noted to store insulin vials by submerging them in water. To examine whether withdrawing insulin from a vial without adding air back causes a vacuum which allows water to enter the vial, resulting in insulin dilution. Seven hundred units of insulin were withdrawn from forty 10 mL vials of 100 units/mL insulin [20 neutral protamine hagedorn (NPH), 20 regular]. In half, air was added back. The vials were weighed (baseline). Half of the vials (10 with added air, 10 without) were submerged in water for 24 h and then air-dried for 24 h. Vials that were not submerged sat at room temperature for 48 h. All vials were weighed 48 h from baseline. Addition of air did not impact the change in weight after submersion (air added: -0.002 ± 0.001 g or -0.2 ± 0.1 unit; no air added: -0.003 ± 0.000 g or -0.3 ± 0 unit, p = 0.57). In a subset of vials in which an additional 240 units were withdrawn before submersion for another 24 h, there was still no difference in weight change in those vials with air added (p = 0.2). Withdrawing insulin from a vial without adding air did not result in uptake of water or dilution of insulin in the submerged vial, although it made drawing up the insulin easier. This study did not address the larger concern of bacterial contamination of the rubber stopper during water storage. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
1986-05-01
according to the following mapping rules: (1) Attributes of objects are dropped: e.g. RED ( b1 ) -I> RED (t ~) -4 .(2) Relations between objects in the...beaker,viai,water, pipe) B1 T2 T3 TEMPERATURE(coffee) TEMPERATURE(ice cube) ’ . B2 B3 PRESSURE(beaker) PRESSURE(vial) GREATER B4 FLOW(ice cube,coffee,heat...Wasnington, DC 20057 ERIC Facility-Acquisitions Dr Kenneth D. Forbus .5 V 4833 Rugby Avenue University of Illinois Dr. Robert Glaser Bethesda, MD 20014
Frédéric Ric, S; Antoine, M; Bodson, A; Lissoir, B
2015-10-01
The objective of this study was to compare an in-house matrix-assisted laser desorption ionization with time of flight (MALDI-TOF) method and a commercial MALDI-TOF kit (Sepsityper(®) kit) for direct bacterial identification in positive blood cultures. We also evaluated the time saved and the cost associated with the rapid identification techniques. We used the BACTEC(®) automated system for detecting positive blood cultures. Direct identification using Sepsityper kit and the in-house method were compared with conventional identification by MALDI-TOF using pure bacterial culture on the solid phase. We also evaluated different cut-off scores for rapid bacterial identification. In total, 127 positive blood vials were selected. The rate of rapid identification with the MALDI Sepsityper kit was 25.2% with the standard cut-off and 33.9% with the enlarged cut-off, while the results for the in-house method were 44.1 and 61.4%, respectively. Error rates with the enlarged cut-off were 6.98 (n = 3) and 2.56% (n = 2) for Sepsityper and the in-house method, respectively. Identification rates were higher for gram-negative bacteria. Direct bacterial identification succeeded in supplying rapid identification of the causative organism in cases of sepsis. The time taken to obtain a result was nearly 24 hours shorter for the direct bacterial identification methods than for conventional MALDI-TOF on solid phase culture. Compared with the Sepsityper kit, the in-house method offered better results and fewer errors, was more cost-effective and easier to use.
A flexible system to capture sample vials in a storage box - the box vial scanner.
Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D
2009-01-01
Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.
System for trapping and storing gases for subsequent chemical reduction to solids
Vogel, John S [San Jose, CA; Ognibene, Ted J [Oakland, CA; Bench, Graham S [Livermore, CA; Peaslee, Graham F [Holland, MI
2009-11-03
A system for quantitatively reducing oxide gases. A pre-selected amount of zinc is provided in a vial. A tube is provided in the vial. The zinc and the tube are separated. A pre-selected amount of a catalyst is provided in the tube. Oxide gases are injected into the vial. The vial, tube, zinc, catalyst, and the oxide gases are cryogenically cooled. At least a portion of the vial, tube, zinc, catalyst, and oxide gases are heated.
Vial OrganicTM-Organic Chemistry Labs for High School and Junior College
NASA Astrophysics Data System (ADS)
Russo, Thomas J.; Meszaros, Mark
1999-01-01
Vial Organic is the most economical, safe, and time-effective method of performing organic chemistry experiments. Activities are carried out in low-cost, sealed vials. Vial Organic is extremely safe because only micro quantities of reactants are used, reactants are contained in tightly sealed vials, and only water baths are used for temperature control. Vial Organic laboratory activities are easily performed within one 50-minute class period. When heat is required, a simple hot-water bath is prepared from a beaker of water and an inexpensive immersion heater. The low cost, ease of use, and relatively short time requirement will allow organic chemistry to be experienced by more students with less confusion and intimidation.
Brueckner, David; Roesti, David; Zuber, Ulrich; Sacher, Meik; Duncan, Derek; Krähenbühl, Stephan; Braissant, Olivier
2017-05-15
Tunable diode laser absorption spectroscopy (TDLAS) was evaluated on its potential to detect bacterial growth of contaminated media fill vials. The target was a replacement/ automation of the traditional visual media fill inspection. TDLAS was used to determine non-invasively O 2 and/or CO 2 changes in headspaces of such vials being induced by metabolically active microorganisms. Four different vial formats, 34 microorganisms (inoculation volume<10 cells) and two different media (TSB/FTM) were tested. Applying parallel CO 2 and O 2 headspace measurements all format-organism combinations were detected within <11 days reliably with reproducible results. False negatives were exclusively observed for samples that were intentionally breached with syringes of 0.3mm in diameter. Overall it was shown that TDLAS functionality for a replacement of the visual media fill inspection is given and that investing in further validation and implementation studies is valuable. Nevertheless, some small but vincible challenges remain to have this technology in practical use. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Hailey, Melinda; Bayuse, Tina
2009-01-01
The need for a new system of injectable medications aboard the International Space Station (ISS) was identified. It is desired that this system fly medications in their original manufacturer's packaging, allowing the system to comply with United States Pharmacopeia (USP) guidelines while minimizing the resupply frequency due to medication expiration. Pre-filled syringes are desired, however, the evolving nature of the healthcare marketplace requires flexibility in the redesign. If medications must be supplied in a vial, a system is required that allows for the safe withdrawal of medication from the vial into a syringe for administration in microgravity. During two reduced gravity flights, the effectiveness of two versions of a blunt cannula and needleless vial adaptors was evaluated to facilitate the withdrawal of liquid medication from a vial into a syringe for injection. Other parameters assessed included the ability to withdraw the required amount of medication and whether this is dependent on vial size, liquid, or the total volume of fluid within the vial. Injectable medications proposed for flight on ISS were used for this evaluation. Due to differing sizes of vials and the fluid properties of the medications, the needleless vial adaptors proved to be too cumbersome to recommend for use on the ISS. The blunt cannula, specifically the plastic version, proved to be more effective at removing medication from the various sizes of vials and are the recommended hardware for ISS. Fluid isolation within the vials and syringes is an important step in preparing medication for injection regardless of the hardware used. Although isolation is a challenge in the relatively short parabolas during flight, it is not an obstacle for sustained microgravity. This presentation will provide an overview of the products tested as well as the challenges identified during the microgravity flights.
Sterility assessment of multiple use botulinum A exotoxin vials: a prospective simulation.
Alam, Murad; Yoo, Simon S; Wrone, David A; White, Lucile E; Kim, John Y S
2006-08-01
A preponderance of evidence now indicates that storage of reconstituted botulinum toxin solution for longer than the 4 hours recommended by the manufacturer does not result in loss of effectiveness. Then purpose of this study was to assess whether serial re-extraction of reconstituted botulinum toxin solution from vials undergoing prolonged storage is associated with increased risk of microbial contamination. Consecutive 100-U vials of botulinun A exotoxin were reconstituted with 2.5 mL each of normal saline with preservative (benzyl alcohol). Within 1 week after reconstitution, each vial was used to treat 1 to 3 patients, for a total of 60 to 80 U used. Thereafter, each vial was stored in a plastic kidney basin in an unlocked, multiuse medication refrigerator. Two weeks later, a randomly assigned nurse removed the vial from the refrigerator and withdrew and discarded 0.1 mL (5 U) using the same technique used for therapeutic extractions. Iterations of this withdrawal and discarding procedure were continued until a 0.1-mL aliquot could not be withdrawn without prying off the metal cover. Once this threshold was reached, the vial was sent to the microbiology laboratory for sterility testing using a thioglycolate broth. In all, 127 vials were handled per protocol. On average (mean), vials underwent 4.5 access procedures, including 1.6 therapeutic extractions for a total of 76 U removed during a period of 7 weeks. Sterility analysis with thioglycolate broth indicated no evidence of contamination. Preservative-containing saline was used for reconstitution. Routine refrigerator storage of medication vials containing reconstituted botulinum toxin does not result in microbial contamination of the contents even after serial re-extraction of solution from these vials, and after handling of such vials by multiple personnel. Storage and subsequent reuse of botulinum toxin appears safe for at least 7 weeks after reconstitution.
Container system for enabling commercial production of cryopreserved cell therapy products.
Woods, Erik J; Bagchi, Aniruddha; Goebel, W Scott; Vilivalam, Vinod D; Vilivalam, Vinod D
2010-07-01
The expansion of cellular therapeutics will require large-scale manufacturing processes to expand and package cell products, which may not be feasible with current blood-banking bag technology. This study investigated the potential for freezing, storing and shipping cell therapy products using novel pharmaceutical-grade Crystal Zenith((R)) (CZ) plastic vials. CZ vials (0.5, 5 and 30 ml volume) with several closure systems were filled with mesenchymal stem cells and stored at either -85 or -196 degrees C for 6 months. Vials were tested for their ability to maintain cell viability, proliferative and differentiation capacity, as well as durability and integrity utilizing a 1-m drop test. As controls, 2 ml polypropylene vials were investigated under the same conditions. Post-thaw viability utilizing a dye exclusion assay was over 95% in all samples. Stored cells exhibited rapid recovery 2 h post-thaw and cultures were approximately 70% confluent within 5-7 days, consistent with nonfrozen controls and indicative of functional recovery. Doubling times were consistent over all vials. The doubling rate for cells from CZ vials were 2.14 + or - 0.83 days (1 week), 1.84 + or - 0.68 days (1 month) and 1.79 + or - 0.71 days (6 months), which were not significantly different compared with frozen and fresh controls. Cells recovered from the vials exhibited trilineage differentiation consistent with controls. As part of vial integrity via drop testing, no evidence of external damage was found on vial surfaces or on closure systems. Furthermore, the filled vials stored for 6 months were tested for container closure integrity. Vials removed from freezer conditions were transported to the test laboratory on dry ice and tested using pharmaceutical packaging tests, including dye ingress and microbial challenge. The results of all stoppered vials indicated container closure integrity with no failures. Pharmaceutical-grade plastic CZ vials, which are commercially used to package pharmaceutical products, are suitable for low-temperature storage and transport of mesenchymal stem cells, and are a scalable container system for commercial manufacturing and fill-finish operation of cell therapy products.
Anti-tubercular agents from Glycyrrhiza glabra.
Kalani, Komal; Chaturvedi, Vinita; Alam, Sarfaraz; Khan, Feroz; Srivastava, Santosh Kumar
2015-01-01
Bioactivity guided isolation of Glycyrrhiza glabra (Leguminosae / Fabaceae) roots resulted in the characterization of 18β-glycyrrhetinic acid as a major anti-tubercular agent. Further, GA-1 was semi-synthetically converted into its nine derivatives, which were in-vitro evaluated for their antitubercular potential against Mycobacterium tuberculosis H37Rv using BACTEC-460 radiometric susceptibility assay. All the derivatives were active, but the benzylamide (GA-8, MIC 12.5μg/ml) and ethyl oxylate (GA-3, MIC 25.0 μg/ml) derivatives were significantly active against the pathogen. This was further supported by the molecular docking studies, which showed adequate docking (LibDock) scores for GA-3 (120.3) and GA-8 (112.6) with respect to the standard anti-tubercular drug, rifampicin (92.94) on the DNA-directed RNA polymerase subunit beta (rpoB) target site. Finally, the in silico pharmacokinetic and drug-likeness studies showed that GA-3 and GA- 8 possesses drug-like properties. This is the first ever report on the anti-tubercular potential of GA and its derivatives. These results may be of great help in anti-tubercular drug development from a very common, inexpensive, and non toxic natural product.
Damm, Markus; Kappe, C Oliver
2011-11-30
A high-throughput platform for performing parallel solvent extractions in sealed HPLC/GC vials inside a microwave reactor is described. The system consist of a strongly microwave-absorbing silicon carbide plate with 20 cylindrical wells of appropriate dimensions to be fitted with standard HPLC/GC autosampler vials serving as extraction vessels. Due to the possibility of heating up to four heating platforms simultaneously (80 vials), efficient parallel analytical-scale solvent extractions can be performed using volumes of 0.5-1.5 mL at a maximum temperature/pressure limit of 200°C/20 bar. Since the extraction and subsequent analysis by either gas chromatography or liquid chromatography coupled with mass detection (GC-MS or LC-MS) is performed directly from the autosampler vial, errors caused by sample transfer can be minimized. The platform was evaluated for the extraction and quantification of caffeine from commercial coffee powders assessing different solvent types, extraction temperatures and times. For example, 141±11 μg caffeine (5 mg coffee powder) were extracted during a single extraction cycle using methanol as extraction solvent, whereas only 90±11 were obtained performing the extraction in methylene chloride, applying the same reaction conditions (90°C, 10 min). In multiple extraction experiments a total of ~150 μg caffeine was extracted from 5 mg commercial coffee powder. In addition to the quantitative caffeine determination, a comparative qualitative analysis of the liquid phase coffee extracts and the headspace volatiles was performed, placing special emphasis on headspace analysis using solid-phase microextraction (SPME) techniques. The miniaturized parallel extraction technique introduced herein allows solvent extractions to be performed at significantly expanded temperature/pressure limits and shortened extraction times, using standard HPLC autosampler vials as reaction vessels. Remarkable differences regarding peak pattern and main peaks were observed when low-temperature extraction (60°C) and high-temperature extraction (160°C) are compared prior to headspace-SPME-GC-MS performed in the same HPLC/GC vials. Copyright © 2011 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... package No. of packages Bandage compress—4″ 1 Single 5 Bandage compress—2″ 4 do 2 Waterproof adhesive..., forceps, scissors, 12 safety pins 1, 1, 1, and 12, respectively Double 1 Wire splint 1 Single 1 Ammonia..., 61/2 gr tablets, vials of 20 5 Double 1 Sterile petrolatum gauze, 3″×18″ 4 Single 3 (c) Instructions...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taketomo, C.K.; Chu, S.A.; Cheng, M.H.
The stability of captopril in powder papers under three different storage conditions was determined. Captopril 12.5-mg tablets were triturated with lactose to a final concentration of 2 mg of captopril in 100 mg of powder. A total of 240 powder papers were prepared and stored in class A prescription vials (80 papers), 002G plastic zip-lock bags (80 papers), and Moisture Proof Barrier Bags (80 papers). Immediately after preparation and at 1, 2, 3, 4, 8, 12, and 24 weeks of storage at room temperature, powder papers under each storage condition were reweighed and the contents were assayed for captopril concentrationmore » by a stability-indicating high-performance liquid chromatographic method. More than 90% of the initial captopril concentration was retained under all storage conditions during the first 12 weeks of the study. Captopril disulfide, a degradation product, was detected in one sample stored in a plastic zip-lock bag at 24 weeks. Captopril was stable for the entire 24-week period in powder papers stored in either the class A prescription vial or the Moisture Proof Barrier Bag. Captopril in powder papers is stable for at least 12 weeks when stored at room temperature under all three storage conditions.« less
Rosa, Mónica; Tiago, João M; Singh, Satish K; Geraldes, Vítor; Rodrigues, Miguel A
2016-10-01
The quality of lyophilized products is dependent of the ice structure formed during the freezing step. Herein, we evaluate the importance of the air gap at the bottom of lyophilization vials for consistent nucleation, ice structure, and cake appearance. The bottom of lyophilization vials was modified by attaching a rectified aluminum disc with an adhesive material. Freezing was studied for normal and converted vials, with different volumes of solution, varying initial solution temperature (from 5°C to 20°C) and shelf temperature (from -20°C to -40°C). The impact of the air gap on the overall heat transfer was interpreted with the assistance of a computational fluid dynamics model. Converted vials caused nucleation at the bottom and decreased the nucleation time up to one order of magnitude. The formation of ice crystals unidirectionally structured from bottom to top lead to a honeycomb-structured cake after lyophilization of a solution with 4% mannitol. The primary drying time was reduced by approximately 35%. Converted vials that were frozen radially instead of bottom-up showed similar improvements compared with normal vials but very poor cake quality. Overall, the curvature of the bottom of glass vials presents a considerable threat to consistency by delaying nucleation and causing radial ice growth. Rectifying the vials bottom with an adhesive material revealed to be a relatively simple alternative to overcome this inconsistency.
Gieseler, Henning; Lee, Geoffrey
2008-02-01
To determine the effects of vial packing density in a laboratory freeze dryer on drying rate profiles of crystalline and amorphous formulations. The Christ freeze-drying balance measured cumulative water loss, m(t), and instantaneous drying rate, m(t), of water, mannitol, sucrose and sucrose/BSA formulations in commercial vials. Crystalline mannitol shows drying rate behaviour indicative of a largely homogeneous dried-product layer. The drying rate behaviour of amorphous sucrose indicates structural heterogeneity, postulated to come from shrinkage or microcollapse. Trehalose dries more slowly than sucrose. Addition of BSA to either disaccharide decreases primary drying time. Higher vial packing density greatly reduces drying rate because of effects of radiation heat transfer from chamber walls to test vial. Plots of m(t) versus radical t and m(t) versus layer thickness (either ice or dried-product) allow interpretation of changes in internal cake morphology during drying. Vial packing density greatly influences these profiles.
A simple device for efficient transfer and unit dose packaging of Xe-127: concise communication.
Kowalsky, R J; Dalton, D R; Saylor, W L
1978-04-01
An inexpensive system has been devised for the efficient transfer of Xe-127 gas from the manufacturer's ampule into individual dose vials for patient use. By displacing the gas with an aqueous solution, the initial transfer is made from an ampule of known activity into an evacuated serum vial of predetermined volume with transfer efficiency greater than 99%. A similar principle is used to transfer Xe-127 from the stock serum vial into individual dose vials, with total xenon recovery exceeding 98%. Ability to deliver the desired activity to each vial is within 90-110% of that predicted by calculation. Reproducibility in delivering a given activity was excellent, with all vials falling between 95 and 105% of the mean activity. Stability studies showed that 94% of the Xe-127 activity can be removed from the vials with only 6% absorbed in the rubber stopper after 5 wk of storage. The device costs less than $25.00 and can be constructed easily from common laboratory materials.
Use of a soft sensor for the fast estimation of dried cake resistance during a freeze-drying cycle.
Bosca, Serena; Barresi, Antonello A; Fissore, Davide
2013-07-15
This paper deals with the determination of dried cake resistance in a freeze-drying process using the Smart Soft Sensor, a process analytical technology recently proposed by the authors to monitor the primary drying stage of a freeze-drying process. This sensor uses the measurement of product temperature, a mathematical model of the process, and the Kalman filter algorithm to estimate the residual amount of ice in the vial as a function of time, as well as the coefficient of heat transfer between the shelf and the product and the resistance of the dried cake to vapor flow. It does not require expensive (additional) hardware in a freeze-dryer, provided that thermocouples are available. At first, the effect of the insertion of the thermocouple in a vial on the structure of the product is investigated by means of experimental tests, comparing both sublimation rate and cake structure in vials with and without thermocouple. This is required to assess that the temperature measured by the thermocouple is the same of the product in the non-monitored vials, at least in a non-GMP environment, or when controlled nucleation methods are used. Then, results about cake resistance obtained in an extended experimental campaign with aqueous solutions containing different excipients (sucrose, mannitol and polyvinylpyrrolidone), processed in various operating conditions, are presented, with the goal to point out the accuracy of the proposed methodology. Copyright © 2013 Elsevier B.V. All rights reserved.
Arshad, Muhammad Sohail; Smith, Geoff; Polygalov, Eugene; Ermolina, Irina
2014-08-01
The aim of this work was to evaluate the application of through-vial impedance spectroscopy in the measurement of eutectic crystallization during the freezing stage of the lyophilisation cycle. Impedance measurements of various sugar solutions (mannitol 5%, 10% and 15% w/v, sucrose 5% w/v and mannitol 5% w/v, and sucrose 5% w/v solutions) were taken during a freeze-thaw cycle, over a frequency range 10-10(6) Hz with a scan interval of 1.5 min, using measurement vials with externally attached electrodes connected to a high resolution impedance analyzer. Estimates for the electrical resistance of the mannitol solutions record the exothermic crystallization of mannitol at a temperature of -24 °C during the temperature ramp down stage of the freezing cycle, which is in close agreement with the off-line DSC measurement of -22 °C. The freezing profile of a 5% mannitol solution with 5% sucrose (a component that does not crystallize in the frozen solution) demonstrated the inhibition of mannitol crystallization (with the implication that the product will then require sub-Tg' freezing and drying). The work suggests a role for through-vial impedance spectroscopy in the concurrent development of the product formulation and freeze drying cycle without the uncertainty introduced when using off-line date to define the critical process parameters. Copyright © 2014 Elsevier B.V. All rights reserved.
Elevated compartment pressures from copperhead envenomation successfully treated with antivenin.
Mazer-Amirshahi, Maryann; Boutsikaris, Amy; Clancy, Cathleen
2014-01-01
Copperhead envenomation causes local soft tissue effects; however, associated compartment syndrome is rare. We report a case of a 17-month-old with significantly elevated compartment pressures successfully treated with antivenin and supportive care. A 17-month-old girl sustained a copperhead bite to the foot and presented with circumferential edema, erythema, and ecchymosis of the foot and distal ankle. The patient had palpable pulses and was neurologically intact. Four vials of Crotalidae polyvalent immune Fab was initiated and additional doses were administered in an attempt to achieve local control. Within 10 h of presentation, the patient's edema extended to the groin, although sensation was maintained and pulses were documented by Doppler. Lower-extremity compartment pressures were measured and were most notable for an anterior pressure of 85 mm Hg, despite having received 12 vials of antivenin. Fasciotomy was deferred and the patient received two additional six-vial doses of antivenin to achieve local control. Compartment pressures improved with a 2.2-cm mean decrease in limb diameter within 48 h. Maintenance dosing was initiated and the patient ultimately received a total of 26 vials of antivenin. The patient did not develop significant coagulopathy or thrombocytopenia. Swelling continued to improve with return of limb function. In this case, early and aggressive treatment with antivenin may have avoided invasive fasciotomy, and its use should be considered in patients with copperhead envenomation and significantly elevated compartment pressures. Copyright © 2014 Elsevier Inc. All rights reserved.
Improving Crotalidae polyvalent immune Fab reconstitution times.
Quan, Asia N; Quan, Dan; Curry, Steven C
2010-06-01
Crotalidae polyvalent immune Fab (CroFab) is used to treat rattlesnake envenomations in the United States. Time to infusion may be a critical factor in the treatment of these bites. Per manufacturer's instructions, 10 mL of sterile water for injection (SWI) and hand swirling are recommended for reconstitution. We wondered whether completely filling vials with 25 mL of SWI would result in shorter reconstitution times than using 10-mL volumes and how hand mixing compared to mechanical agitation of vials or leaving vials undisturbed. Six sets of 5 vials were filled with either 10 mL or 25 mL. Three mixing techniques were used as follows: undisturbed; agitation with a mechanical agitator; and continuous hand rolling and inverting of vials. Dissolution was determined by observation and time to complete dissolution for each vial. Nonparametric 2-tailed P values were calculated. Filling vials completely with 25 mL resulted in quicker dissolution than using 10-mL volumes, regardless of mixing method (2-tailed P = .024). Mixing by hand was shorter than other methods (P < .001). Reconstitution with 25 mL and hand mixing resulted in the shortest dissolution times (median, 1.1 minutes; range, 0.9-1.3 minutes). This appeared clinically important because dissolution times using 10 mL and mechanical rocking of vials (median, 26.4 minutes) or leaving vials undisturbed (median, 33.6 minutes) was several-fold longer. Hand mixing after filling vials completely with 25 mL results in shorter dissolution times than using 10 mL or other methods of mixing and is recommended, especially when preparing initial doses of CroFab. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Aluminum in erythropoietin formulations: lyophilized versus liquid forms.
Veiga, Marlei; Bohrer, Denise; Noremberg, Simone; Mattiazzi, Patricia; do Nascimento, Paulo C; de Carvalho, Leandro M
2013-01-01
Erythropoietin (EPO) formulations may comprise aluminum (Al) as a contaminant. Due to the toxicity of Al in chronic kidney disease patients, possible sources of Al were investigated. Since EPO formulations are stored in container-closure systems made of glass and rubber, and both contain Al, formulation ingredients may enable its leaching into the solution during shelf-life. Individual solutions of formulation ingredients were stored in new glass vials and in contact with the rubber stopper and kept at 4 ± 2 °C. For 12 months, aliquots of each solution were collected for analysis. Fifteen commercial samples of EPO were analyzed for their Al content. Aluminum was determined by atomic absorption spectrometry. Glass and rubber are sources of Al for EPO formulations. Storage assay showed that citrate and phosphate (used as buffers) extracted high amounts of Al from the container/closure parts. The most important difference, however, was found when comparing liquid and lyophilized samples. While in liquid forms the Al level reached 943 μg/L, in lyophilized forms the level did not exceed 20 μg/L. The container system was also confirmed as a source of Al in reconstituted lyophilized samples. Al in reconstituted samples stored in their own vials increased 19-fold in 12 months. Lyophilized powders stored for 2 years in glass vials contained less Al than in 1 month after dissolution. The difference in the Al measured in liquid forms of EPO and in lyophilized powders suggests that the latter would be the best pharmaceutical form for CKD patients.
Cobos-Triguero, N; Zboromyrska, Y; Morata, L; Alejo, I; De La Calle, C; Vergara, A; Cardozo, C; Arcas, M P; Soriano, A; Marco, F; Mensa, J; Almela, M; Martínez, J A
2017-02-01
The aim of this study was to determine the usefulness of oxidase test and time-to-positivity (TTP) in aerobic and anaerobic blood culture vials to detect the presence of Pseudomonas aeruginosa in patients with Gram-negative bacilli (GNB) bacteraemia. TTP was recorded for each aerobic and anaerobic blood culture vial of monomicrobial bacteraemia due to GNB. Oxidase test was performed in a pellet of the centrifuged content of the positive blood culture. An algorithm was developed in order to perform the oxidase test efficiently taking into account TTP and type of vial. A total of 341 episodes of GNB bacteraemia were analysed. Sensitivity, specificity, positive predictive value and negative predictive value of the oxidase test performed on positive vials with GNB to predict P. aeruginosa were 95%, 99%, 91%, and 99%, respectively. When growth was first or exclusively detected in anaerobic vials, P. aeruginosa was never identified hence the performance of the oxidase test could be avoided. When growth was only or first detected in aerobic vials, a TTP≥8h predicted P. aeruginosa in 37% or cases (63 of 169), therefore oxidase test is highly recommended. Oxidase test performed onto positive blood culture vials previously selected by TTP and type of vials is an easy and inexpensive way to predict P. aeruginosa. In most cases, this can lead to optimization of treatment in less than 24 hours.
[Streptomycin as second-line chemotherapy for tuberculosis].
Ruiz, P; Rodríguez-Cano, F; Zerolo, F J; Casal, M
2003-06-01
Streptomycin was the first antibiotic to be used against Mycobacterium tuberculosis. It was used for years in monotherapy regimens, thereby resulting in the appearance of resistance and the relegation of its use. The resistance detected against drugs currently employed has led to a renewed interest in streptomycin. Its mechanism of action is centered on the ribosome, inhibiting the protein synthesis of the microbacteria. Resistance appears when mutations in the genes codifying for rRNA 16S and for protein S12 are produced. We studied the use of streptomycin against 899 M. tuberculosis strains, 713 of which were from pulmonary and 186 from extrapulmonary isolates. The BACTEC 460 TB system was initially employed as was the ESP II system. As controls, the ATCC27294 pattern strains (susceptible to streptomycin, rifampicin, ethambutol and isoniazid) were used. The results showed 2.1% secondary resistance in all the cases. Multiresistance was observed in 12 strains.
A whole blood bactericidal assay for tuberculosis.
Wallis, R S; Palaci, M; Vinhas, S; Hise, A G; Ribeiro, F C; Landen, K; Cheon, S H; Song, H Y; Phillips, M; Dietze, R; Ellner, J J
2001-04-15
The bactericidal activity of orally administered antituberculosis (anti-TB) drugs was determined in a whole blood culture model of intracellular infection in which microbial killing reflects the combined effects of drug and immune mechanisms. Rifampin (Rif) was the most active compound studied and reduced the number of viable bacilli by >4 logs. Isoniazid (INH), 2 quinolones, and pyrazinamide (PZA) showed intermediate levels of activity. Ethambutol exerted only a bacteristatic effect; amoxicillin/clavulanate was inactive. The combination of INH-Rif-PZA showed strong activity against 11 drug-sensitive isolates (mean, -3.8 log) but no activity against 12 multidrug-resistant (MDR) strains. The combination of levofloxacin-PZA-ethambutol had intermediate bactericidal activity against MDR isolates (mean, -1.2 log) but failed to equal that of INH-Rif-PZA against sensitive isolates (P<.001). The whole blood BACTEC method (Becton Dickinson) may be useful for the early clinical evaluation of new anti-TB drugs and in the management of individual patients.
A new approach for pyrazinamide susceptibility testing in Mycobacterium tuberculosis.
Zimic, Mirko; Loli, Sebastian; Gilman, Robert H; Gutierrez, Andrés; Fuentes, Patricia; Cotrina, Milagros; Kirwan, Daniela; Sheen, Patricia
2012-08-01
Pyrazinamide (PZA) is an important drug in the treatment of tuberculosis. Microbiological methods of PZA susceptibility testing are controversial and have low reproducibility. After conversion of PZA into pyrazinoic acid (POA) by the bacterial pyrazinamidase enzyme, the drug is expelled from the bacteria by an efflux pump. To evaluate the rate of POA extrusion from Mycobacterium tuberculosis as a parameter to detect PZA resistance. The rate of POA extrusion and PZA susceptibility determined by BACTEC 460 were measured for 34 strains in a previous study. PZA resistance was modeled in a logistic regression with the pyrazinoic efflux rate. POA efflux rate predicted PZA resistance with 70.83%-92.85% sensitivity and 100% specificity compared with BACTEC 460. POA efflux rate could be a useful tool for predicting PZA resistance in M. tuberculosis. Further exploration of this approach may lead to the development of new tools for diagnosing PZA resistance, which may be of public health importance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bibby, R; Guthrie, E
2009-01-30
The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exteriormore » of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.« less
Predictions of vacuum loss of evacuated vials from initial air leak rates.
Prisco, Michael R; Ochoa, Jorge A; Yardimci, Atif M
2013-08-01
Container closure integrity is a critical factor for maintaining product sterility and stability. Therefore, closure systems (found in vials, syringes, and cartridges) are designed to provide a seal between rubber stoppers and glass containers. To ensure that the contained product has maintained its sterility and stability at the time of deployment, the seal must remain intact within acceptable limits. To this end, a mathematical model has been developed to describe vacuum loss in evacuated drug vials. The model computes equivalent leak diameter corresponding to initial air leak rate as well as vacuum loss as a function of time and vial size. The theory accounts for three flow regimes that may be encountered. Initial leak rates from 10(-8) to 10(3) sccm (standard cubic centimeters per minute) were investigated for vials ranging from 1 to 100 mL. Corresponding leak diameters of 0.25-173 μm were predicted. The time for a vial to lose half of its vacuum, the T50 value, ranged from many years at the lowest leak rates and largest vials, to fractions of a second at the highest leak rates and smallest vials. These results may be used to determine what level of initial vacuum leak is acceptable for a given product. Copyright © 2013 Wiley Periodicals, Inc.
Cost of goods sold and total cost of delivery for oral and parenteral vaccine packaging formats.
Sedita, Jeff; Perrella, Stefanie; Morio, Matt; Berbari, Michael; Hsu, Jui-Shan; Saxon, Eugene; Jarrahian, Courtney; Rein-Weston, Annie; Zehrung, Darin
2018-03-14
Despite limitations of glass packaging for vaccines, the industry has been slow to implement alternative formats. Polymer containers may address many of these limitations, such as breakage and delamination. However, the ability of polymer containers to achieve cost of goods sold (COGS) and total cost of delivery (TCOD) competitive with that of glass containers is unclear, especially for cost-sensitive low- and lower-middle-income countries. COGS and TCOD models for oral and parenteral vaccine packaging formats were developed based on information from subject matter experts, published literature, and Kenya's comprehensive multiyear plan for immunization. Rotavirus and inactivated poliovirus vaccines (IPV) were used as representative examples of oral and parenteral vaccines, respectively. Packaging technologies evaluated included glass vials, blow-fill-seal (BFS) containers, preformed polymer containers, and compact prefilled auto-disable (CPAD) devices in both BFS and preformed formats. For oral vaccine packaging, BFS multi-monodose (MMD) ampoules were the least expensive format, with a COGS of $0.12 per dose. In comparison, oral single-dose glass vials had a COGS of $0.40. BFS MMD ampoules had the lowest TCOD of oral vaccine containers at $1.19 per dose delivered, and ten-dose glass vials had a TCOD of $1.61 per dose delivered. For parenteral vaccines, the lowest COGS was achieved with ten-dose glass vials at $0.22 per dose. In contrast, preformed CPAD devices had the highest COGS at $0.60 per dose. Ten-dose glass vials achieved the lowest TCOD of the parenteral vaccine formats at $1.56 per dose delivered. Of the polymer containers for parenteral vaccines, BFS MMD ampoules achieved the lowest TCOD at $1.89 per dose delivered, whereas preformed CPAD devices remained the most expensive format, at $2.25 per dose delivered. Given their potential to address the limitations of glass and reduce COGS and TCOD, polymer containers deserve further consideration as alternative approaches for vaccine packaging. Copyright © 2018 PATH. Published by Elsevier Ltd.. All rights reserved.
Diriba, Getu; Kebede, Abebaw; Yaregal, Zelalem; Getahun, Muluwork; Tadesse, Mengistu; Meaza, Abyot; Dagne, Zekarias; Moga, Shewki; Dilebo, Jibril; Gudena, Kebebe; Hassen, Mulu; Desta, Kassu
2017-05-10
Bacteriological confirmed active case detection remains the corner stone for diagnosing tuberculosis. Non-radiometric liquid culture system Mycobacterium Growth Indicator Tube with automated interface had been recommended by expert groups in addition to conventional solid culture media such as Lowenstein-Jensen. However in high burden resource limited countries advanced non-radiometric based tuberculosis diagnostic methods such as MGIT 960 is limited. Therefore we have evaluated the performance of MGIT 960 system compared to LJ for recovery of Mycobacterium complex (MTBC) from clinical specimens. A cross sectional study was conducted from a total of 908 samples between January 1st, 2013 to December 31st, 2014. Clinical specimens were processed following standard procedures and the final suspension was inoculated to MGIT tubes and LJ slant. Identification and confirmation of MTBC was done by ZN staining and SD Bioline test. Data was analyzed by SPSS version 20. The sensitivity, specificity, recovery rate and the average turnaround time to recover the organism was computed. From a total of 908 clinical specimens processed using both LJ and BACTEC MGIT liquid culture methods the recovery rate for LJ and MGIT, for smear positive samples was 66.7% (74/111) and 87.4% (97/ 111) respectively while for smear negative samples was 13.4% (108/797) and 17.4% (139/797) for LJ and MGIT methods respectively. The overall recovery rate for MGIT is significantly higher than LJ methods [26% (236/908; vs. 20%, 182/908, P = 0.002)]. The average turnaround time for smear positive samples was 16 and 31 days for MGIT and LJ respectively. Turnaround time for smear negative samples was 20 and 36 days for MGIT and LJ respectively. The overall agreement between MGIT and LJ was fairly good with Kappa value of 0.59 (P < 0.001). In the present study the contamination rate for MGIT is higher than the LJ methods, 15 and 9.3% respectively. The BACTEC MGIT liquid culture system has better MTBC recovery rate with shorter turnaround time for both smear positive and negative clinical specimens compared to Conventional LJ method. However, efforts should be made in order to reduce the high contamination rate in BACTEC MGIT system and to lesser extent to LJ methods.
Economic and microbiologic evaluation of single-dose vial extension for hazardous drugs.
Rowe, Erinn C; Savage, Scott W; Rutala, William A; Weber, David J; Gergen-Teague, Maria; Eckel, Stephen F
2012-07-01
The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000.
Voskanian, K Sh
2004-01-01
Oncoginic transformations of mouse fibroblasts C3H10T1/2 after exposure to proton energies 150 and 584 MeV were compared with fibroblast effects of gamma-radiation. Prior to exposure, cell populations (2.7 x 10(3) cells/cm2) were inoculated in plastic vials with the surface area of 75 cm2 and cultivated 11 days. Survivability was determined by comparing the number of cell colonies in irradiated and non-irradiated (control) vials. Transformation rate was calculated by dividing the total transformation focus number by the number of survived cells in a vial. Rate of oncogenic transformations after gamma- and proton (584 MeV) irradiation was essentially identical, i.e. the parameter grew rapidly at the doses < 1 Gy and slowed down at the doses > 1 Gy. In the dose interval between 1 and 5 Gy, transformation rate for proton energy 150 MeV was found low compared with gamma-radiation and proton energy 584 MeV. It is hypothesized that the different transformation rate after exposure to proton energy 150 MeV is linked with the high linear energy transfer as compared with the proton energy of 584 MeV and gamma-radiation.
Improving birth dose coverage of hepatitis B vaccine.
Hipgrave, David B.; Maynard, James E.; Biggs, Beverley-Ann
2006-01-01
Administration of a birth dose of hepatitis B vaccine (HepB vaccine) to neonates is recommended to prevent mother-to-infant transmission and chronic infection with the hepatitis B virus (HBV). Although manufacturers recommend HepB vaccine distribution and storage at 2-8 degrees C, recognition of the heat stability of hepatitis B surface antigen stimulated research into its use after storage at, or exposure to, ambient or high temperatures. Storage of HepB vaccine at ambient temperatures would enable birth dosing for neonates delivered at home in remote areas or at health posts lacking refrigeration. This article reviews the current evidence on the thermostability of HepB vaccine when stored outside the cold chain (OCC). The reports reviewed show that the vaccines studied were safe and effective whether stored cold or OCC. Field and laboratory data also verifies the retained potency of the vaccine after exposure to heat. The attachment of a highly stable variety of a vaccine vial monitor (measuring cumulative exposure to heat) on many HepB vaccines strongly supports policies allowing their storage OCC, when this will benefit birth dose coverage. We recommend that this strategy be introduced to improve birth dose coverage, especially in rural and remote areas. Concurrent monitoring and evaluation should be undertaken to affirm the safe implementation of this strategy, and assess its cost, feasibility and effect on reducing HBV infection rates. Meanwhile, release of manufacturer data verifying the potency of currently available HepB vaccines after exposure to heat will increase confidence in the use of vaccine vial monitors as a managerial tool during storage of HepB vaccine OCC. PMID:16501717
A SIMPLE TUMBLING DEVICE USED IN PREPARING ALGAL SPECIMENS FOR ELECTRON MICROSCOPY.
Berlagnolli, B L; Nadakavukaren, M J
1969-06-01
Screw cap vials are held in a wooden holder which rotates at a 90° angle to the horizontal. The. shaft of a small electric motor with built-in gear box is attached perpendicularly to the wooden vial holder via a hole drilled in the center of the wooden holder. The rotation of the vial holder is about 6 rpm. This motion ensures a thorough tumbling of the contents of the vials. Even viscous embedding media are kept in constant agitation, which provides for superior penetration of the tissue. Tumbling devices to hold a range of vial sizes can be constructed with a minimum of labor at a cost of $10-20 each.
Dhamodharan, Aswin; Proano, Ruben A
2012-09-01
Outreach immunization services, in which health workers immunize children in their own communities, are indispensable to improve vaccine coverage in rural areas of developing countries. One of the challenges faced by these services is how to reduce high levels of vaccine wastage. In particular, the open vial wastage (OVW) that result from the vaccine doses remaining in a vial after a time for safe use -since opening the vial- has elapsed. This wastage is highly dependent on the choice of vial size and the expected number of participants for which the outreach session is planned (i.e., session size). The use single-dose vials results in zero OVW, but it increases the vaccine purchase, transportation, and holding costs per dose as compared to those resulting from using larger vial sizes. The OVW also decreases when more people are immunized in a session. However, controlling the actual number of people that show to an outreach session in rural areas of developing countries highly depends on factors that are out of control of the immunization planners. This paper integrates a binary integer-programming model to a Monte Carlo simulation method to determine the choice of vial size and the optimal reordering point level to implement an (nQ, r, T) lot-sizing policy that provides the best tradeoff between procurement costs and wastage.
Stanford, K; Reuter, T; Gilroyed, B H; McAllister, T A
2015-04-01
To investigate impact of sporulation and compost temperatures on feasibility of composting for disposal of carcasses contaminated with Bacillus anthracis. Two strains of B. cereus, 805 and 1391, were sporulated at either 20 or 37°C (Sporulation temperature, ST) and 7 Log10 CFU g(-1) spores added to autoclaved manure in nylon bags (pore size 50 μm) or in sealed vials. Vials and nylon bags were embedded into compost in either a sawdust or manure matrix each containing 16 bovine mortalities (average weight 617 ± 33 kg), retrieved from compost at intervals over 217 days and survival of B. cereus spores assessed. A ST of 20°C decreased spore survival by 1·4 log10 CFU g(-1) (P < 0·05) compared to a 37°C ST. Spore survival was strain dependent. Compost temperatures >55°C reduced spore survival (P < 0·05) and more frequently occurred in the sawdust matrix. Sporulation and compost temperatures were key factors influencing survival of B. cereus spores in mortality compost. Composting may be most appropriate for the disposal of carcasses infected with B. anthracis at ambient temperatures ≤20°C under thermophillic composting conditions (>55°C). © 2015 The Society for Applied Microbiology.
Samant, Y; Lanjewar, H; Parker, L; Block, D; Stein, B; Tomar, G
2007-01-01
The potency of oral polio vaccine (OPV), a heat-labile vaccine, is preserved by the cold chain. The Vaccine Vial Monitor, a heat-sensitive label, is critical to the monitoring and maintenance of the cold chain. This study was conducted to evaluate the relationship between the adequacy of cold chain infrastructure and the proper use of Vaccine Vial Monitor in a rural district of India. Forty-six health centers in a rural district were included in our evaluation of the cold chain equipment and the Vaccine Vial Monitors. Cold chain equipment and vaccine vials within each health center were evaluated for adherence to WHO cold chain maintenance protocols and the Vaccine Vial Monitor stage, respectively. Among the 46 health centers, Vaccine Vial Monitor stage I was found at 58% of the health centers, 33% of the health centers reported stage II and 9% reported a stage III, indicating weaknesses in the cold chain mechanism Cold chain for the OPV was not adequately maintained at primary and sub-health centers in this rural district. Well maintained ice packs and vaccine carriers will help ensure delivery and availability of a safe and potent vaccine to children in rural areas of India.
Obeidat, Wasfy M; Sahni, Ekneet; Kessler, William; Pikal, Michael
2018-02-01
The goal of the work described in this publication was to evaluate a new, small, material-sparing freeze dryer, denoted as the "mini-freeze dryer or mini-FD", capable of reproducing the product temperature history of larger freeze dryers, thereby facilitating scale-up. The mini-FD wall temperatures can be controlled to mimic loading procedures and dryer process characteristics of larger dryers. The mini-FD is equipped with a tunable diode laser absorption spectroscopy (TDLAS) water vapor mass flow monitor and with other advanced process analytical technology (PAT) sensors. Drying experiments were performed to demonstrate scalability to larger freeze dryers, including the determination of vial heat transfer coefficients, K v . Product temperature histories during K v runs were evaluated and compared with those obtained with a commercial laboratory-scale freeze dryer (LyoStar II) for sucrose and mannitol product formulations. When the mini-FD wall temperature was set at the LyoStar II band temperature (- 20°C) to mimic lab dryer edge vials, edge vial drying in the mini-FD possessed an average K v within 5% of those obtained during drying in the LyoStar II. When the wall temperature of the mini-FD was set equal to the central vial product temperature, edge vials behaved as center vials, possessing a K v value within 5% of those measured in the LyoStar II. During both K v runs and complete product freeze drying runs, the temperature-time profiles for the average edge vials and central vial in the mini-FD agreed well with the average edge and average central vials of the LyoStar II.
Kamler, Martin; Nesvorna, Marta; Stara, Jitka; Erban, Tomas; Hubert, Jan
2016-05-01
The parasitic mite Varroa destructor is a major pest of the western honeybee, Apis mellifera. The development of acaricide resistance in Varroa populations is a global issue. Discriminating concentrations of acaricides are widely used to detect pest resistance. Two methods, using either glass vials or paraffin capsules, are used to screen for Varroa resistance to various acaricides. We found the glass vial method to be useless for testing Varroa resistance to acaridices, so we developed a polypropylene vial bioassay. This method was tested on tau-fluvalinate-, acrinathrin-, and amitraz-resistant mite populations from three apiaries in Czechia. Acetone was used as a control and technical grade acaricide compounds diluted in acetone were applied to the polypropylene vials. The solutions were spread on the vial surface by rolling the vial, and were then evaporated. Freshly collected Varroa females were placed in the vials and the mortality of the exposed mites was measured after 24 h. The Varroa populations differed in mortality between the apiaries and the tested compounds. Mites from the Kyvalka site were resistant to acrinathrin, tau-fluvalinate, and amitraz, while mites from the Postrizin site were susceptible to all three acaricides. In Prelovice apiary, the mites were susceptible to acrinathrin and amitraz, but not to tau-fluvalinate. The calculated discriminating concentrations for tau-fluvalinate, acrinathrin, and amitraz were 0.66, 0.26 and 0.19 µg/mL, respectively. These results indicate that polyproplyne vial tests can be used to determine discriminating concentrations for the early detection of acaricide resistant Varroa. Finally, multiple-resistance in Kyvalka may indicate metabolic resistance.
Economic and Microbiologic Evaluation of Single-Dose Vial Extension for Hazardous Drugs
Rowe, Erinn C.; Savage, Scott W.; Rutala, William A.; Weber, David J.; Gergen-Teague, Maria; Eckel, Stephen F.
2012-01-01
Purpose: The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Methods: Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. Results: The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. Conclusion: The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000. PMID:23180998
Quality evaluation of radiographic contrast media in large-volume prefilled syringes and vials.
Sendo, T; Hirakawa, M; Yaginuma, M; Aoyama, T; Oishi, R
1998-06-01
The authors compared the particle contaminations of radiographic contrast media packaged in large-volume prefilled syringes and vials. Particle counting was performed for four contrast media packaged in large-volume prefilled syringes (iohexol, ioversol, ioversol for angiography, and ioxaglate) and three contrast media packaged in vials (iohexol, ioversol, and ioxaglate). X-ray emission spectrometry was performed to characterize the individual particles. The amount of silicone oil in the syringe was quantified with infrared spectrophotometry. The particle contamination in syringes containing ioversol was higher than that in syringes containing iohexol or ioxaglate. Particle contamination in the vials was relatively low, except with ioxaglate. X-ray emission spectrometry of the components of the syringe and vial showed that the source of particles was internal material released from the rubber stopper or inner surface. The particle counts for contrast media packaged in syringes and vials varied considerably among the different contrast media and were related to the amount of silicone oil on the inner surface and rubber piston of the syringe.
Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes.
Mushtaq, Ahmad; Ur Rehman, Taj; Safdar Mansur, Muhammad; Jehangir, Mustanser
2008-06-01
Many groups have reported the adsorption or retention of (99m)Tc-radiopharmaceuticals on injection vials and disposable plastic syringes. Such an enormously high loss of radioactivity would result in poor images, radiation exposure, waste, and economic burdens. We therefore decided to investigate the extent of adsorption or retention of several (99m)Tc-radiopharmaceuticals on injection vials, rubber stoppers, and plastic syringes. These radiopharmaceuticals are produced as lyophilized kits in our department and supplied to various hospitals practicing nuclear medicine in Pakistan. A vial containing lyophilized material was reconstituted with 3 mL of freshly eluted Na(99m)TcO(4). A 1-mL aliquot of the resulting solution was withdrawn into a syringe at 0.25, 0.5, 1, 3, and 5 h after preparation. All preparations were stored at room temperature ( approximately 22 degrees C). After each withdrawal, the vial was reweighed and the activity remaining in the vial was measured using a radioisotope calibrator. The sample was reinjected into the vial. From the original weight and activity of solution in the vial, the initial activity per gram was calculated. From the weight and activity remaining in the vial after withdrawal of the sample, the activity per gram of the sample was calculated. From the difference between the initial activity per gram and the activity per gram of the sample, the percentage of (99m)Tc adsorbed on the vial was calculated. All preparations were kept in the syringe for 15 min, and the activity was measured before and after the syringe was emptied. The needle and plunger of the syringe were separated, and activity in the needle and plunger was also measured. The labeling efficiency of all radiopharmaceuticals used during these studies was more than 95%. In most cases, the activity of (99m)Tc found on the rubber stopper was less than 1%. Adsorption of (99m)Tc onto vials increased gradually with storage time. Adsorption was minimal at the initial stages, whereas maximum retention was noted after 5 h. Nearly 5% adsorption of activity was observed after 5 h of storage time on vials of sestamibi, mercaptoacetyltriglycine, dextran, ciprofloxacin, and dimercaptosuccinic acid (III and V). Retention of activity on needles ranged from 1% to 2% for all preparations studied. Plungers did not show any significant retention of radioactivity; in most cases, retention was less than 0.5%. The maximum retention of radioactivity on plastic syringe bodies was more than 3% for sestamibi, dimercaptosuccinic acid, dextran, pyrophosphate, and phytate. The results revealed that losses of radioactivity from (99m)Tc-radiopharmaceuticals in these objects (glass vial, rubber stopper, plastic syringes, plungers, and needles) are not alarming in our setup.
Safety and efficacy of Crotalidae Polyvalent Immune Fab in pediatric crotaline envenomations.
Pizon, Anthony F; Riley, Bradley D; LoVecchio, Frank; Gill, Ruqayya
2007-04-01
Since it was approved by the Food and Drug Administration in October 2000, Crotalidae Polyvalent Immune Fab (CroFab) has largely replaced previously used crotaline antivenom. CroFab is more specifically tailored for crotalids of North America and is less allergenic than whole immunoglobulin antivenoms. However, premarketing and postmarketing studies have excluded children. To describe the safety and efficacy of CroFab in pediatric crotaline envenomations. Using admission and billing records, the authors identified all children 13 years of age and younger treated with CroFab at a pediatric hospital between October 2000 and September 2005. Charts were reviewed by two trained, blinded extractors. Data regarding age, signs of envenomation, laboratory values, total antivenom vials used, total vials used to gain control, transfused blood products, signs of acute allergy to antivenom, and any surgical procedures were abstracted. Data were analyzed using descriptive statistics. Twenty-four patients were identified, and their mean age was 7.3 (range, 1.9-13) years. At presentation, all had swelling, 14 (58%) had a prothrombin time >13 seconds, two (8.3%) had a fibrinogen level <150 mg/dL, and three (12.5%) had platelet counts <150,000/mL. The mean number of total antivenom vials used was 12.3 (range, 4-24). Five patients had resolution of swelling, but platelet counts continued to fall despite antivenom treatment. No patient required blood products, debridement of skin, or fasciotomy. There was only one (4.2%) possible acute allergy to CroFab, and there were no deaths. In this pediatric series, CroFab appears safe and effective, despite occasional resistant thrombocytopenia.
Kuu, Wei Y; Nail, Steven L; Sacha, Gregory
2009-03-01
The purpose of this study was to perform a rapid determination of vial heat transfer parameters, that is, the contact parameter K(cs) and the separation distance l(v), using the sublimation rate profiles measured by tunable diode laser absorption spectroscopy (TDLAS). In this study, each size of vial was filled with pure water followed by a freeze-drying cycle using a LyoStar II dryer (FTS Systems) with step-changes of the chamber pressure set-point at to 25, 50, 100, 200, 300, and 400 mTorr. K(cs) was independently determined by nonlinear parameter estimation using the sublimation rates measured at the pressure set-point of 25 mTorr. After obtaining K(cs), the l(v) value for each vial size was determined by nonlinear parameter estimation using the pooled sublimation rate profiles obtained at 25 to 400 mTorr. The vial heat transfer coefficient K(v), as a function of the chamber pressure, was readily calculated, using the obtained K(cs) and l(v) values. It is interesting to note the significant difference in K(v) of two similar types of 10 mL Schott tubing vials, primary due to the geometry of the vial-bottom, as demonstrated by the images of the contact areas of the vial-bottom. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association
Costanza, Jed; Pennell, Kurt D
2008-02-01
The rates of hydrolysis reported for tetrachloroethylene (PCE) and trichloroethylene (TCE) at elevated temperatures range over two orders-of-magnitude, where some of the variability may be due to the presence of a gas phase. Recent studies suggest that volatile organic analysis (VOA) vials provide a low-cost and readily available zero headspace system for measuring aqueous-phase hydrolysis rates. This work involved measuring rates of PCE and TCE disappearance and the corresponding appearance of dechlorination products in water-filled VOA vials and flame-sealed ampules incubated at 21 and 55 degrees C for up to 95.5 days. While PCE and TCE concentrations readily decreased in the VOA vials to yield first-order half lives of 11.2 days for PCE and 21.1 days for TCE at 55 degrees C, concentrations of anticipated dechlorination products, including chloride, remained constant or were not detected. The rate of PCE disappearance was 34 times faster in VOA vials at 55 degrees C compared to values obtained with flame-sealed ampules containing PCE-contaminated water. In addition, the concentration of TCE increased slightly in flame-sealed ampules incubated at 55 degrees C, while a decrease in TCE levels was observed in the VOA vials. The observed losses of PCE and TCE in the VOA vials were attributed to diffusion and sorption in the septa, rather than to dechlorination. These findings demonstrate that VOA vials are not suitable for measuring rates of volatile organic compound hydrolysis at elevated temperatures.
21 CFR 522.1002 - Follicle stimulating hormone.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Follicle stimulating hormone. 522.1002 Section 522....1002 Follicle stimulating hormone. (a)(1) Specifications. Each package contains 2 vials. One vial... hormone. The other vial contains 10 milliliters of aqueous diluent. (2) Sponsor. See 059521 in § 510.600(c...
21 CFR 522.1002 - Follicle stimulating hormone.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Follicle stimulating hormone. 522.1002 Section 522....1002 Follicle stimulating hormone. (a)(1) Specifications. Each package contains 2 vials. One vial... hormone. The other vial contains 10 milliliters of aqueous diluent. (2) Sponsor. See No. 052923 in § 510...
Scutellà, Bernadette; Bourlès, Erwan; Plana-Fattori, Artemio; Fonseca, Fernanda; Flick, Denis; Trelea, Ioan-Cristian; Passot, Stephanie
2018-04-14
During the freeze-drying process, vials located at the border of the shelf usually present higher heat flow rates that result in higher product temperatures than vials in the center. This phenomenon, referred to as edge vial effect, can lead to product quality variability within the same batch of vials and between batches at different scales. Our objective was to investigate the effect of various freeze dryer design features on heat transfer variability. A 3D mathematical model previously developed in COMSOL Multiphysics and experimentally validated was used to simulate the heat transfer of a set of vials located at the edge and in the center of the shelf. The design features considered included the vials loading configurations, the thermal characteristics, and some relevant dimensions of the drying chamber geometry. The presence of the rail in the loading configuration and the value of the shelf emissivity strongly impacted the heat flow rates received by the vials. Conversely, the heat transfer was not significantly influenced by modifications of the thermal conductivity of the rail, the emissivity of the walls, or the geometry of the drying chamber. The model developed turned out to be a powerful tool for cycle development and scale-up. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Is it safe to re-access sodium bicarbonate bottles for use in minor surgery?
Bjornson, Lindsay; Bucevska, Marija; Tilley, Peter; Verchere, Cynthia
2018-04-06
Sodium bicarbonate is added to lidocaine to reduce injection pain. In Canada, it is available in vials exceeding the injection volume 100-fold. These are single-use vials that should be disposed of after one access. Some surgeons re-use vials to reduce waste, potentially causing contamination. This study aims to review the safety of sodium bicarbonate and assess alternatives to current practice. Strains of Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Burkholderia cepacia were used to assess bacterial growth in vials of sodium bicarbonate. Each pathogen was inoculated into a vial for 14 days at room temperature. At several time points, 1 mL of solution was removed and diluted. One hundred microliters were transferred to blood agar plates and incubated at 35 °C. Colony counts were calculated, averaged and plotted onto a logarithmic graph. Colony counts of all strains fell below observational threshold after 7 days in sodium bicarbonate. Although all strains were reduced, bacteria can survive in sodium bicarbonate for several days, during which transmission may occur. Sodium bicarbonate vials should be treated as single-dose, as indicated by the manufacturers. To reduce waste, hospital pharmacies can repackage sodium bicarbonate into smaller vials or pre-alkalize lidocaine with sodium bicarbonate. Copyright © 2018 Elsevier Inc. All rights reserved.
Kargupta, Roli; Puttaswamy, Sachidevi; Lee, Aiden J; Butler, Timothy E; Li, Zhongyu; Chakraborty, Sounak; Sengupta, Shramik
2017-06-10
Multiple techniques exist for detecting Mycobacteria, each having its own advantages and drawbacks. Among them, automated culture-based systems like the BACTEC-MGIT™ are popular because they are inexpensive, reliable and highly accurate. However, they have a relatively long "time-to-detection" (TTD). Hence, a method that retains the reliability and low-cost of the MGIT system, while reducing TTD would be highly desirable. Living bacterial cells possess a membrane potential, on account of which they store charge when subjected to an AC-field. This charge storage (bulk capacitance) can be estimated using impedance measurements at multiple frequencies. An increase in the number of living cells during culture is reflected in an increase in bulk capacitance, and this forms the basis of our detection. M. bovis BCG and M. smegmatis suspensions with differing initial loads are cultured in MGIT media supplemented with OADC and Middlebrook 7H9 media respectively, electrical "scans" taken at regular intervals and the bulk capacitance estimated from the scans. Bulk capacitance estimates at later time-points are statistically compared to the suspension's baseline value. A statistically significant increase is assumed to indicate the presence of proliferating mycobacteria. Our TTDs were 60 and 36 h for M. bovis BCG and 20 and 9 h for M. smegmatis with initial loads of 1000 CFU/ml and 100,000 CFU/ml respectively. The corresponding TTDs for the commercial BACTEC MGIT 960 system were 131 and 84.6 h for M. bovis BCG and 41.7 and 12 h for M smegmatis, respectively. Our culture-based detection method using multi-frequency impedance measurements is capable of detecting mycobacteria faster than current commercial systems.
Chan, Tze-Ming; Pramanik, Birendra; Aslanian, Robert; Gullo, Vincent; Patel, Mahesh; Cronin, Bart; Boyce, Chris; McCormick, Kevin; Berlin, Mike; Zhu, Xiaohong; Buevich, Alexei; Heimark, Larry; Bartner, Peter; Chen, Guodong; Pu, Haiyan; Hegde, Vinod
2009-02-20
Investigation of unexpected levels of impurities in Intron product has revealed the presence of low levels of impurities leached from the silicone tubing (Rehau RAU-SIK) on the Bosch filling line. In order to investigate the effect of these compounds (1a, 1b and 2) on humans, they were isolated identified and synthesized. They were extracted from the tubing by stirring in Intron placebo at room temperature for 72 h and were enriched on a reverse phase CHP-20P column, eluting with gradient aqueous ACN and were separated by HPLC. Structural elucidation of 1a, 1b and 2 by MS and NMR studies demonstrated them to be halogenated biphenyl carboxylic acids. The structures were confirmed by independent synthesis. Levels of extractable impurities in first filled vials of actual production are estimated to be in the range of 0.01-0.55 microg/vial for each leached impurity. Potential toxicity of these extractables does not represent a risk for patients under the conditions of clinical use.
A New Approach for Pyrazinamide Susceptibility Testing in Mycobacterium tuberculosis
Loli, Sebastian; Gilman, Robert H.; Gutierrez, Andrés; Fuentes, Patricia; Cotrina, Milagros; Kirwan, Daniela; Sheen, Patricia
2012-01-01
Background: Pyrazinamide (PZA) is an important drug in the treatment of tuberculosis. Microbiological methods of PZA susceptibility testing are controversial and have low reproducibility. After conversion of PZA into pyrazinoic acid (POA) by the bacterial pyrazinamidase enzyme, the drug is expelled from the bacteria by an efflux pump. Objective: To evaluate the rate of POA extrusion from Mycobacterium tuberculosis as a parameter to detect PZA resistance. Methods: The rate of POA extrusion and PZA susceptibility determined by BACTEC 460 were measured for 34 strains in a previous study. PZA resistance was modeled in a logistic regression with the pyrazinoic efflux rate. Result: POA efflux rate predicted PZA resistance with 70.83%–92.85% sensitivity and 100% specificity compared with BACTEC 460. Conclusion: POA efflux rate could be a useful tool for predicting PZA resistance in M. tuberculosis. Further exploration of this approach may lead to the development of new tools for diagnosing PZA resistance, which may be of public health importance. PMID:22372927
[Preparation of a kind of SERS-active substrates for spot fast analysis].
Ji, Nan; Li, Zhi-Shi; Zhao, Bing; Zou, Bo
2013-02-01
A kind of SERS-active substrates was prepared using chemical self-assembly method, aiming at spot fast analysis using portable Raman spectrometer. PDDA was first absorbed on the inner wall of vials, and then Ag colloids were assembled on the inner wall. UV-Vis spectra and Raman spectra of two kinds of blank vials were investigated and the transparent vials were thought to be better for SERS-vials. UV-Vis spectra were used to monitor the assembly process of Ag colloids. SERS activity of our substrates was characterized using p-ATP as probing molecules.
49 CFR 173.4b - De minimis exceptions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... quantities of Ethanol (UN1170), Formaldehyde solution, flammable (UN1198), Alcohols, n.o.s. (UN1987) and... paper towel or cheesecloth moistened with alcohol or an alcohol solution and placed in a plastic bag that is heat-sealed. Any free liquid in the bag must not exceed 30 mL; or (ii) Placed in vials or other...
49 CFR 173.4b - De minimis exceptions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... quantities of Ethanol (UN1170), Formaldehyde solution, flammable (UN1198), Alcohols, n.o.s. (UN1987) and... paper towel or cheesecloth moistened with alcohol or an alcohol solution and placed in a plastic bag that is heat-sealed. Any free liquid in the bag must not exceed 30 mL; or (ii) Placed in vials or other...
49 CFR 173.4b - De minimis exceptions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... quantities of Ethanol (UN1170), Formaldehyde solution, flammable (UN1198), Alcohols, n.o.s. (UN1987) and... paper towel or cheesecloth moistened with alcohol or an alcohol solution and placed in a plastic bag that is heat-sealed. Any free liquid in the bag must not exceed 30 mL; or (ii) Placed in vials or other...
The incidence of coring with blunt versus sharp needles.
Wani, Tariq; Wadhwa, Anupama; Tobias, Joseph D
2014-03-01
With the advent of safety needles to prevent inadvertent needle sticks in the operating room (OR), a potentially new issue has arisen. These needles may result in coring, or the shaving off of fragments of the rubber stopper, when the needle is pierced through the rubber stopper of the medication vial. These fragments may be left in the vial and then drawn up with the medication and possibly injected into patients. The current study prospectively evaluated the incidence of coring when blunt and sharp needles were used to pierce rubber topped vials. We also evaluated the incidence of coring in empty medication vials with rubber tops. The rubber caps were then pierced with either an18-gauge sharp hypodermic needle or a blunt plastic (safety) needle. Coring occurred in 102 of 250 (40.8%) vials when a blunt needle was used versus 9 of 215 (4.2%) vials with a sharp needle (P < 0.0001). A significant incidence of coring was demonstrated when a blunt plastic safety needle was used. This situation is potentially a patient safety hazard and methods to eliminate this problem are needed. Copyright © 2014 Elsevier Inc. All rights reserved.
Lack of latex allergen contamination of solutions withdrawn from vials with natural rubber stoppers.
Thomsen, D J; Burke, T G
2000-01-01
The effect on latex allergen contamination and microbial growth of a latex-allergy precaution technique for preparing injectable products was studied. The study consisted of three parts: (1) preparation of 20 samples from vials with latex-containing stoppers in accordance with conventional guidelines, (2) preparation of 20 samples in accordance with latex-allergy precaution guidelines, and (3) preparation of 5 latex-free samples and 1 latex-contaminated sample as negative and positive controls, respectively. The conventional method involved swabbing a vial top with an alcohol prep pad, puncturing the dry natural rubber stopper with an 18-gauge needle attached to a latex-free syringe, and withdrawing the contents of the vial into the syringe. The latex-allergy precaution preparation technique was similar, except that the stopper was removed before the vial contents were withdrawn. There was essentially no difference in latex allergen concentrations between the two drug preparation methods. None of the samples prepared with the standard method supported any microbial growth. One sample prepared with the latex-allergy precaution method grew bacteria. Removal of the dry rubber stopper from vials did not yield solutions with less latex allergen than solutions prepared according to conventional guidelines.
Stability of stabilized 99mTc-D,L-HMPAO stored in vials and syringes.
Del Carmen Plancha-Mansanet, Maria; Caballero-Calabuig, Elisa; Félix-Fontestad, Jesús; Reyes-Ojeda, María Dolores; Sopena-Novales, Pablo; Abreu-Sánchez, Pedro; Del Carmen Cano-Terol, Maria; Sopena-Monforte, Ramón
2008-12-01
Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared. The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h. The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.
Xiouras, Christos; Radacsi, Norbert; Sturm, Guido; Stefanidis, Georgios D
2016-08-23
We investigate the existence of specific/nonthermal microwave effects for the dehydration reaction of xylose to furfural in the presence of NaCl. Such effects are reported for sugars dehydration reactions in several literature reports. To this end, we adopted three approaches that compare microwave-assisted experiments with a) conventional heating experiments from the literature; b) simulated conventional heating experiments using microwave-irradiated silicon carbide (SiC) vials; and at c) different power levels but the same temperature by using forced cooling. No significant differences in the reaction kinetics are observed using any of these methods. However, microwave heating still proves advantageous as it requires 30 % less forward power compared to conventional heating (SiC vial) to achieve the same furfural yield at a laboratory scale. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Poisson, Patrick; Sinclair, Colin S; Tallentire, Alan
2006-01-01
Controlled challenges with air dispersed microorganisms having widely different resistances to dry heat, carried out on 624 BFS machine processing growth medium, have shown that higher the heat resistance, the greater the extent of vial contamination. Differences in heat resistance affected also the extent of vial contamination when parison and vial formation were knowingly manipulated through changes made to each of three process variables, provision of ballooning air, mould vacuum delay, and parison extrusion rate. The findings demonstrate that, in this investigational system, exposure of challenge micoorganisms to heat inherent in the process has a controlling influence on vial contamination, an influence that could also control microbiological risk in production environments.
Sng, Li-Hwei; Peh, Justine Woei Ling; Lee Kee, Melody Tai; Ya'akob, Nurhazirah Bte Mohd; Ong, Rick Twee-Hee; Wong, Christopher W; Chee, Cynthia Bin Eng; Wang, Yee Tang
2018-06-08
Accurate and reliable drug susceptibility testing (DST) is essential for the effective treatment and control of tuberculosis. With the increase in drug-resistant organisms, newer and less conventional antimicrobial agents are used for treatment. Recently, we found an unprecedented rise in the number of clofazimine-resistant Mycobacterium tuberculosis isolates in our laboratory. An investigation found that this phenomenon was due to a change in the method of drug preparation. We performed studies to assess the impact of water and dimethyl sulfoxide (DMSO) as a final diluent for clofazimine drug testing. Based on our findings, the use of DMSO as a solvent for M. tuberculosis DST was optimised using the BACTEC MGIT 960 platform. Copyright © 2018 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Potential use of autoinjector-packaged antidotes for treatment of pediatric nerve agent toxicity.
Henretig, Fred M; Mechem, Crawford; Jew, Rita
2002-10-01
We sought to determine the feasibility of discharging Mark 1 atropine and pralidoxime autoinjectors into small, sterile vials to facilitate the potential intramuscular injection of these antidotes, particularly pralidoxime, on a milligram per kilogram basis to small children. Autoinjectors were swabbed with isopropyl alcohol and then discharged into emptied, sterile, plastic 10-mL vials. This was repeated with the investigator garbed in standard personal protective gloves and full face mask and hood. The autoinjector injection surfaces were cultured. The autoinjectors were easily discharged into the vials without need for practice or special dexterity, even when investigators were garbed in protective gear. A small core of rubber stopper might be injected into the vial, and thus, the vial contents need to be withdrawn through a filter needle before reinjection. The autoinjector injection surfaces were sterile after alcohol swabbing. Autoinjectors might be a readily available source of concentrated pralidoxime for potential intramuscular use in small children.
Frank, Kerstin J; Boeck, Georg
2016-05-25
The aim was to develop a nanosuspension of the poorly soluble BI XX. The nanosuspension is intended for intravenous (iv) administration in preclinical studies and should not cause any unwanted side effects. Thus, only stabilizers that are accepted for iv application should be used and isotonicity, euhydria and the absence of living microorganisms were targeted. Suspensions were prepared in a ball-mill (mixing mill MM 400 from Retsch). There were various vials used as containers; HPLC-vials were used for the small scale screening of stabilizers and injection vials for preparation of larger quantities of the nanosuspensions. Particle size distribution was analyzed by laser diffraction measurement (Mastersizer 2000). Lyophilization was used for processing of the suspensions (Christ freeze dryer). Stable nanosuspensions (d90 remained <1μm up to 7days) were prepared with several FDA-accepted stabilizers. Freeze drying was evaluated for one formulation containing 2% of the API, 0.5% of arginine and 4% of mannitol. The particle size distribution before freeze drying and after re-dispersion was comparable. After milling for 2h, no living microorganisms were detected in the nanosuspension. Various FDA accepted excipients were identified which resulted in stable nanosuspensions of BI XX. The most stable formulation was successfully freeze dried. It was proven that milling in the ball-mill decreases the presence of living microorganisms. Copyright © 2016. Published by Elsevier B.V.
Improved optics for an ultracentrifuge
NASA Technical Reports Server (NTRS)
Miller, C. G.; Stephens, J. B.
1980-01-01
Ultracentrifuge is important tool in study of polymers, biomolecules, and cell structures. In typical ultracentrifuge rotor supports pair of optically matched vials; one contains sample mixed in solvent, and other is reference that contains only solvent. Doubleslit optical system, transverse to rotor, creates interference pattern on photographic plate each time vials pass through optics. Medium in sample vial displaces interference maximums such that shift gives measurement of density distribution along length of sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rand, J.B.; Johnson, C.D.
1981-09-15
A single-vial liquid extraction assay for choline acetyltransferase that uses (/sup 3/H)choline as the labeled substrate has been devised. (/sup 3/H)Choline is incubated with an excess of acetyl-CoA in a small reaction vial which also serves as a scintillation vial. After a suitable reaction period, unreacted (/sup 3/H)choline is quickly and quantitatively converted to phosphoryl-(/sup 3/H)choline by the addition of an excess of choline kinase. This treatment is followed by the addition of scintillation fluid containing sodium tetraphenylboron after which the vial is capped, shaken, and counted. A two-phase system is produced in which product (/sup 3/H)choline is selectively extractedmore » into the scintillation fluid, where is is counted. Phosphoryl-(/sup 3/H)choline remains in the aqueous phase and is not counted. This assay is rapid, simple, and quite sensitive. In comparison to assays using acetyl-CoA as the labeled substrate, it is less sensitive to interference by other enzymes and thus more suitable for measuring choline acetyltransferase in crude extracts and in the initial stages of purificaton. Similar single-vial radiometric assays are described for choline kinase and acetyl-CoA hydrolases.« less
Buck, David; Subramanyam, Rajeev; Varughese, Anna
2016-01-01
The use of a single-dose vial across multiple patients presents a risk to sterility and is against CDC guidelines. We initiated a quality improvement (QI) project to reduce the intraoperative use of single-dose vials of fentanyl across multiple patients at Cincinnati Children's Hospital Medical Center (CCHMC). The initial step of the improvement project was the development of a Key Driver Diagram. The diagram has the SMART aim of the project, key drivers inherent to the process we are trying to improve, and specific interventions targeting the key drivers. The number of patients each week receiving an IV dose of fentanyl, from a vial previously accessed for another patient was tracked in a high turnover operating room (OR). The improvement model used was based on the concept of building Plan-Do-Study-Act (PDSA) cycles. Tests of change included provider education, provision of an increased number of fentanyl vials, alternate wasting processes, and provision of single-use fentanyl syringes by the pharmacy. Prior to initiation of this project, it was common for a single fentanyl vial to be accessed for multiple patients. Our data showed an average percentage of failures of just over 50%. During the end of the project, after 7 months, the mean percentage failures had dropped to 5%. Preparation of 20 mcg single-use fentanyl syringes by pharmacy, combined with education of providers on appropriate use, was successful in reducing failures to below our goal of 25%. Appropriately sized fentanyl syringes prepared by pharmacy, education on correct use of single-dose vials, and reminders in the OR, reduced the percentage of patients receiving a dose of fentanyl from a vial previously accessed for another patient in a high-volume otolaryngology room. © 2015 John Wiley & Sons Ltd.
Molecular characterization of the 17D-204 yellow fever vaccine.
Salmona, Maud; Gazaignes, Sandrine; Mercier-Delarue, Severine; Garnier, Fabienne; Korimbocus, Jehanara; Colin de Verdière, Nathalie; LeGoff, Jerome; Roques, Pierre; Simon, François
2015-10-05
The worldwide use of yellow fever (YF) live attenuated vaccines came recently under close scrutiny as rare but serious adverse events have been reported. The population identified at major risk for these safety issues were extreme ages and immunocompromised subjects. Study NCT01426243 conducted by the French National Agency for AIDS research is an ongoing interventional study to evaluate the safety of the vaccine and the specific immune responses in HIV-infected patients following 17D-204 vaccination. As a preliminary study, we characterized the molecular diversity from E gene of the single 17D-204 vaccine batch used in this clinical study. Eight vials of lyophilized 17D-204 vaccine (Stamaril, Sanofi-Pasteur, Lyon, France) of the E5499 batch were reconstituted for viral quantification, cloning and sequencing of C/prM/E region. The average rate of virions per vial was 8.68 ± 0.07 log₁₀ genome equivalents with a low coefficient of variation (0.81%). 246 sequences of the C/prM/E region (29-33 per vials) were generated and analyzed for the eight vials, 25 (10%) being defective and excluded from analyses. 95% of sequences had at least one nucleotide mutation. The mutations were observed on 662 variant sites distributed through all over the 1995 nucleotides sequence and were mainly non-synonymous (66%). Genome variability between vaccine vials was highly homogeneous with a nucleotide distance ranging from 0.29% to 0.41%. Average p-distances observed for each vial were also homogeneous, ranging from 0.15% to 0.31%. This study showed a homogenous YF virus RNA quantity in vaccine vials within a single lot and a low clonal diversity inter and intra vaccine vials. These results are consistent with a recent study showing that the main mechanism of attenuation resulted in the loss of diversity in the YF virus quasi-species. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Saat, Ahmad; Hamzah, Zaini; Yusop, Mohammad Fariz; Zainal, Muhd Amiruddin
2010-07-01
Detection efficiency of a gamma-ray spectrometry system is dependent upon among others, energy, sample and detector geometry, volume and density of the samples. In the present study the efficiency calibration curves of newly acquired (August 2008) HPGe gamma-ray spectrometry system was carried out for four sample container geometries, namely Marinelli beaker, disc, cylindrical beaker and vial, normally used for activity determination of gamma-ray from environmental samples. Calibration standards were prepared by using known amount of analytical grade uranium trioxide ore, homogenized in plain flour into the respective containers. The ore produces gamma-rays of energy ranging from 53 keV to 1001 keV. Analytical grade potassium chloride were prepared to determine detection efficiency of 1460 keV gamma-ray emitted by potassium isotope K-40. Plots of detection efficiency against gamma-ray energy for the four sample geometries were found to fit smoothly to a general form of ɛ = AΕa+BΕb, where ɛ is efficiency, Ε is energy in keV, A, B, a and b are constants that are dependent on the sample geometries. All calibration curves showed the presence of a "knee" at about 180 keV. Comparison between the four geometries showed that the efficiency of Marinelli beaker is higher than cylindrical beaker and vial, while cylindrical disk showed the lowest.
Ribas Antúnez, María de los Angeles; Girón, Blanca; Monsalvez, Iraima; Morier, Luis; Acosta, Gretel; Tejero, Yahisel; Cordero, Yanislet; Piedra, Dainelyd
2013-04-01
Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.
Eller, F J; King, J W
2001-10-01
This study investigated the supercritical carbon dioxide (SC-CO(2)) extraction of fat from ground beef and the effects of several factors on the gravimetric determination of fat. The use of ethanol modifier with the SC-CO(2) was not necessary for efficient fat extraction; however, the ethanol did increase the coextraction of water. This coextraction of water caused a significant overestimation of gravimetric fat. Oven-drying ground beef samples prior to extraction inhibited the subsequent extraction of fat, whereas oven-drying the extract after collection decreased the subsequent gas chromatographic fatty acid methyl ester (GC-FAME) fat determination. None of the drying agents tested were able to completely prevent the coextraction of water, and silica gel and molecular sieves inhibited the complete extraction of fat. Measurements of collection vial mass indicated that CO(2) extraction/collection causes an initial increase in mass due to the density of CO(2) (relative to displaced air) followed by a decrease in vial mass due to the removal of adsorbed water from the collection vial. Microwave-drying of the empty collection vials removes approximately 3 mg of adsorbed water, approximately 15-20 min is required for readsorption of the displaced water. For collection vials containing collected fat, microwave-drying effectively removed coextracted water, and the vials reached equilibration after approximately 10-15 min. Silanizing collection vials did not significantly affect weight loss during microwave-drying. SC-CO(2) can be used to accurately determine fat gravimetrically for ground beef, and the presented method can also be followed by GC-FAME analysis to provide specific fatty acid information as well.
Flor-Weiler, Lina B; Behle, Robert W; Stafford, Kirby C
2011-03-01
Toxicity of nootkatone was determined in laboratory assays against unfed nymphs of Amblyomma americanum L., Dermacentor variabilis (Say), Ixodes scapularis Say, and Rhipicephalus sanguineus Latreille. We determined the 50% lethal concentration (LC50) and 90% lethal concentration (LC90) of nootkatone by recording tick mortality 24 h after exposure in treated glass vials. Nymphs were susceptible to nootkatone with LC50 values of 0.352, 0.233, 0.169, and 0.197 microg/cm2, and LC90 values of 1.001, 0.644, 0.549, and 0.485 microg/cm2 for A. americanum, D. variabilis, I. scapularis, and R. sanguineus, respectively. The LC50 value for R. sanquineus was not significantly different from D. variabilis or I. scapularis. Other LC50 comparisons were significantly different. The LC90 for A. americanum was higher when compared with the three other tick species, which were not significantly different. Because nootkatone is volatile, we measured the amount of nootkatone recovered from duplicate-treated vials before tick exposure and from vials after tick exposure. Nootkatone recovered from vials before exposure ranged from 82 to 112% of the expected amounts. The nootkatone recovered after the 24-h exposure period ranged from 89% from vials coated with higher concentrations of nootkatone, down to 29% from vials coated with low nootkatone concentrations. Determination of the nootkatone residue after vial coating demonstrated loss of the active compound while verifying the levels of tick exposure. Toxicity of low concentrations of nootkatone to the active questing stage of ticks reported in this study provides a reference point for future formulation research to exploit nootkatone as a safe and environment-friendly tick control.
Nicholson, Brooke E.; Beaudoin, Claire S.; Detweiler, Angela M.; Bebout, Brad M.
2014-01-01
Methane production has been observed in a number of hypersaline environments, and it is generally thought that this methane is produced through the use of noncompetitive substrates, such as the methylamines, dimethylsulfide and methanol. Stable isotope measurements of the produced methane have also suggested that the methanogens are operating under conditions of substrate limitation. Here, substrate limitation in gypsum-hosted endoevaporite and soft-mat hypersaline environments was investigated by the addition of trimethylamine, a noncompetitive substrate for methanogenesis, and dried microbial mat, a source of natural organic matter. The δ13C values of the methane produced after amendments were compared to those in unamended control vials. At all hypersaline sites investigated, the δ13C values of the methane produced in the amended vials were statistically lower (by 10 to 71‰) than the unamended controls, supporting the hypothesis of substrate limitation at these sites. When substrates were added to the incubation vials, the methanogens within the vials fractionated carbon isotopes to a greater degree, resulting in the production of more 13C-depleted methane. Trimethylamine-amended samples produced lower methane δ13C values than the mat-amended samples. This difference in the δ13C values between the two types of amendments could be due to differences in isotope fractionation associated with the dominant methane production pathway (or substrate used) within the vials, with trimethylamine being the main substrate used in the trimethylamine-amended vials. It is hypothesized that increased natural organic matter in the mat-amended vials would increase fermentation rates, leading to higher H2 concentrations and increased CO2/H2 methanogenesis. PMID:25239903
Ludwig, J D; Davis, C W
1995-01-01
Instron Residual Seal Force (IRSF) of 13 mm glass vial/rubber closure systems was determined using an Instron 4501 Materials Testing System and computerized data analysis. A series of three cap anvils varying in shape and dimensions were machined to optimize cap anvil performance. Cap anvils with spherical top surfaces and narrow internal dimensions produced uniform stress-deformation curves from which precise IRSF values were derived.
... How the Test is Performed Because they are temperature sensitive, cryoglobulins are hard to accurately measure. The ... The vial should be at room or body temperature before it is used. Vials that are colder ...
Walpita, P; Darougar, S
1989-07-01
The development and application of a double-label immunofluorescence method which has the potential to screen for single or dual infections from any site, in single shell vial cultures, is described. In this study, a total of 1,141 ocular specimens were inoculated in shell vials, centrifuged at 15,000 X g for 1 h, incubated at 37 degrees C for 48 h, and fixed in methanol at room temperature for 15 min. The virus inclusions were detected by staining with a double-label indirect immunofluorescence procedure using mixtures of appropriate first antibodies, followed by fluorescein- and rhodamine-conjugated second antibodies. Each specimen was also inoculated in parallel by the conventional virus isolation method. The sensitivity and specificity of the double-label shell vial procedure were comparable to those with the conventional method, and the former test took only 48 h to complete. The test offers a rapid and simple single-vial procedure which allows for individual or simultaneous detection of multiple pathogens. It results in savings in time and cost over the conventional virus isolation method and other shell vial procedures.
Characteristics of high-purity Teflon vial for 14C measurement in old tree rings
NASA Astrophysics Data System (ADS)
Sakurai, H.; Saswaki, Y.; Matsumoto, T.; Aoki, T.; Kato, W.; Gandou, T.; Gunji, S.; Tokanai, F.
2003-06-01
14C concentration in single-year tree rings of an old cedar of ca. 2500 years ago is measured to investigate the 11-yr periodicity of solar activity. Our highly accurate 14C measuring system is composed of a benzene synthesizer capable of producing a large quantity (10 g) of benzene and a Quantulus 1220™ liquid scintillation counting system. The accuracy is less than 0.2% for measurements of 14C concentration. The benzene sample is contained in a high-purity Teflon/copper-counting vial (20 ml) manufactured by Wallac Oy Company. We found a vial with an irregular copper cap for the measurements of 11 tree rings. The behavior of the vial with the irregular cap was investigated. The Teflon sheet inside the cap plays an important role in achieving stable measurement. The rate of volatilization of the benzene was less than 0.35 mg/day for vials with ordinary caps. This results in the volatilization rate of 0.003% for 10.5 g of benzene and hence guarantees measurement at an accuracy of 0.2% for 70 days.
Gieseler, Henning; Lee, Geoffrey
2008-01-01
A freeze-drying balance was used to determine momentary drying-rate, m(t), of a sucrose/BSA formulation contained in a vial with varying shelf packing density, Ø2. A comparison between two different laboratory-scale freeze-dryers was made. The effects of Ø2 on m(t) differed between the two units, attributed to drying chamber design and its effects on heat transfer. At high Ø2 the differences are annulled because of the shielding effects of surrounding vials. Parallel effects of Ø2 were also found on product temperature, Tb, measured in the balance vial. Tb was used to calculate vial heat transfer coefficient, Kv. Kv was strongly reduced with increasing Ø2, but reached a plateau value at high Ø2.
2012-08-01
Interstate Technology & Regulatory Council, Washington, DC, Copyright 2007. McHugh T.E., D.E. Hammond, T. Nickels , and B. Hartman. 2008. Use of...based corrective action have realized significant cost savings for their corrective action programs (Connor and McHugh , 2002). As described above...Groundwater (Tier 2) VOCs USEPA 8260B 40 mL VOA vial HCl 14 days Vapor (Tier 2 and Tier 3) Radon McHugh et al., 2008 500 mL Tedlar bag None 14
Antitubercular activity of pentacyclic triterpenoids from plants of Argentina and Chile.
Wächter, G A; Valcic, S; Flagg, M L; Franzblau, S G; Montenegro, G; Suarez, E; Timmermann, B N
1999-11-01
Screening of plants from South America for antitubercular activity and subsequent assay-guided fractionation resulted in the isolation and characterization of several pentacyclic triterpenoids. The MIC values of 22 triterpenoids were determined using the radiorespiratory BACTEC assay and range from 8 microM to above 128 microM. The structure-activity relationships are discussed.
Rao, Vatturi Venkata Satya Prabhakar; Manthri, Ranadheer; Hemalatha, Pottumuthu; Kumar, Vuyyuru Navin; Azhar, Mohammad
2016-01-01
Hot lab dispensing of large doses of 18 fluorine fluorodeoxyglucose in master vials supplied from the cyclotrons requires high degrees of skill to handle high doses. Presently practiced conventional method of fractionating from the inverted tiltable vial pig mounted on a metal frame has its own limitations such as increasing isotope handling times and exposure to the technologist. Innovative technique devised markedly improves the fractionating efficiency along with speed, precision, and reduced dose exposure. PMID:27095872
Fate of Thallium(I) in Reverse Osmosis and Chlorinated Water Matrices
2014-02-01
pKa of 13 for aquated Tl + , and that the precise nature of the hydrated ion in solution is not well established. 7 No further reactions of the Tl...of Tl + may be viewed as arising from a physical phenomenon. Because of the nature of the vial containing the thallium salt solution, it may be that...loss of thallium concentration was a result of adsorption of Tl + on the vial walls. Plastic vials are known to have significant adsorption
Apparatus and process for collection of gas and vapor samples
Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA
2008-04-01
A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.
Reina, J; Ballesteros, F; Mari, M; Munar, M
2001-01-01
Aims—To compare prospectively the efficacy of the Vero, LLC-MK2, MDCK, Hep-2, and MRC-5 cell lines in the isolation of the mumps virus from clinical samples by means of the shell vial method. Methods—During an epidemic outbreak of parotiditis 48 clinical samples (saliva swabs and CSF) were studied. Two vials of the Vero, LLC-MK2, MDCK, MRC-5, and Hep-2 cell lines were inoculated with 0.2 ml of the samples by the shell vial assay. The vials were incubated at 36°C for two and five days. The vials were then fixed with acetone at -20°C for 10 minutes and stained by a monoclonal antibody against mumps virus by means of an indirect immunofluorescence assay. Results—The mumps virus was isolated from 36 samples. The Vero and LLC-MK2 cell lines showed a 100% isolation capacity, MDCK showed 77.7%, MRC-5 showed 44.4%, and Hep-2 showed 22.2%. The Vero and LLC-MK2 lines were significantly different to the other cell lines (p < 0.001). The sensitivity for the Vero and LLC-MK2 lines at two and five days of incubation was identical (100%). The values obtained in the study of the quantitative isolation capacity (positive isolation with > 5 infectious foci) were 94.4% for Vero, 97.2% for LLC-MK2, 5.5% for MDCK, 5.5% for Hep-2, and 0% for MRC-5. Conclusions—The Vero and LLC-MK2 cell lines are equally efficient at two and five days incubation for the isolation of the mumps virus from clinical samples, and the use of the shell vial method considerably shortens the time of aetiological diagnosis with higher specificity. Key Words: mumps virus • Vero cell line • LLC-MK2 cell line • MDCK cell line • Hep-2 cell line • MRC-5 cell line • isolation • shell vial PMID:11729211
2011-01-01
Background Many countries, such as Niger, are considering changing their vaccine vial size presentation and may want to evaluate the subsequent impact on their supply chains, the series of steps required to get vaccines from their manufacturers to patients. The measles vaccine is particularly important in Niger, a country prone to measles outbreaks. Methods We developed a detailed discrete event simulation model of the vaccine supply chain representing every vaccine, storage location, refrigerator, freezer, and transport device (e.g., cold trucks, 4 × 4 trucks, and vaccine carriers) in the Niger Expanded Programme on Immunization (EPI). Experiments simulated the impact of replacing the 10-dose measles vial size with 5-dose, 2-dose and 1-dose vial sizes. Results Switching from the 10-dose to the 5-dose, 2-dose and 1-dose vial sizes decreased the average availability of EPI vaccines for arriving patients from 83% to 82%, 81% and 78%, respectively for a 100% target population size. The switches also changed transport vehicle's utilization from a mean of 58% (range: 4-164%) to means of 59% (range: 4-164%), 62% (range: 4-175%), and 67% (range: 5-192%), respectively, between the regional and district stores, and from a mean of 160% (range: 83-300%) to means of 161% (range: 82-322%), 175% (range: 78-344%), and 198% (range: 88-402%), respectively, between the district to integrated health centres (IHC). The switch also changed district level storage utilization from a mean of 65% to means of 64%, 66% and 68% (range for all scenarios: 3-100%). Finally, accounting for vaccine administration, wastage, and disposal, replacing the 10-dose vial with the 5 or 1-dose vials would increase the cost per immunized patient from $0.47US to $0.71US and $1.26US, respectively. Conclusions The switch from the 10-dose measles vaccines to smaller vial sizes could overwhelm the capacities of many storage facilities and transport vehicles as well as increase the cost per vaccinated child. PMID:21635774
Lysák, Daniel; Holubová, Monika; Bergerová, Tamara; Vávrová, Monika; Cangemi, Giuseppina Cristina; Ciccocioppo, Rachele; Kruzliak, Peter; Jindra, Pavel
2016-03-01
Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10-100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10-100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and allows their timely release for clinical application.
Cytotoxicity of selected medicinal plants used in Mt. Frere District, South Africa.
Mnengi, Dorris; Kappo, Abidemi; Kambizi, Learnmore; Nakin, Motebang
2014-01-01
In South African traditional medicine, some are plants known to combat pediatric diseases and are commonly used by traditional healers. The aim was to evaluate cytotoxicity effects of plants. The ground plant material was exhaustively extracted using methanol, acetone and water separately for 72 hrs. These organic solvents were removed from filtrates using a rotavapour. Stock solutions were prepared at 40 mg/ml Dimethyl sulfoxide (DMSO) and test solutions were transferred into vials and 10 brine shrimps introduced in each. The number of dead shrimps was counted to ascertain toxicity. Ten A. salina nauplii (larva) were transferred into each sample vial and filtered brine solution was added to make 5 ml. The nauplii were counted macroscopically in the stem of the pipette against a lighted background. A drop of dry yeast suspension was added as food to each vial. Probit analysis was used to determine the concentration at which lethality to brine shrimp represents 50 % (LC50). All the tested extracts showed that the concentration is directly proportional to death of brine shrimps. Fifty percent lethality (LC50) of the tested crude extract ranged between 4.1 and 4.6 µg/ml with methanol extract of B. abyssinica being the lowest and T. acutiloba the highest. This study revealed that 100% of plant crude extracts screened for activity against Artemisia salina larvae showed strong cytotoxicity below 10 µg/ml and plant species with LC50 values < 1000 µg/ml may not make good paediatric remedies due to their inherent toxicity.
A high-potency, single-donor cryoprecipitate of known factor VIII content dispensed in vials.
McLeod, B C; Sassetti, R J; Cole, E R; Scott, J P
1987-01-01
Current factor VIII products expose recipients to many donors and hence to a high risk of acquiring blood-borne infections. Plasma-exchange donation of cryoprecipitate can reduce donor exposure by repeatedly obtaining large yields of factor VIII from individual donors. In this study, donor factor VIII levels were stimulated with desmopressin before donation. Mean yield per donation increased from 1399 +/- 425 IU in controls to 3818 +/- 1350 IU in stimulated donations (p less than 0.001), and mean factor VIII concentration in the cryoprecipitate increased from 8.2 +/- 3 IU/mL to 24 +/- 12 IU/mL (p less than 0.001). A new packaging system dispenses assayed aliquots of stimulated cryoprecipitate in plastic vials. The direct cost of production for this material is $.065 per unit. The cryoprecipitate is hemostatically active and convenient to use, and the aggregate yields from sequential donations by stimulated persons are high enough to allow long-term, single-donor support of many adults with hemophilia.
Drawing medicine out of a vial
... page: //medlineplus.gov/ency/patientinstructions/000530.htm Drawing medicine out of a vial To use the sharing ... a clean area. Wash your hands. Check Your Medicine Carefully check your medicine: Check the label. Make ...
NASA Astrophysics Data System (ADS)
Alad'Ev, S. I.
1987-04-01
Crystal growth in vertical and horizontal cylindrical vials, with the substrate and the source serving as the vial ends, is investigated analytically, assuming that the medium consists of a binary mixture of an active and an inert gas. The active gas is made up of the gaseous products of reactions taking place at the substrate and at the source. It is shown that turbulent free convection leads to an increase in crystal growth rate. All other conditions being equal, crystal growth in vertical vials is greater than that in horizontal ones; in both cases crystal growth rate increases with the vial radius, temperature gradient in the gas phase, and gas phase density. The results are compared with experimental data on the growth of Ge crystals in the Ge-GeI4 system.
Johnston, Christopher I.; O'Leary, Margaret A.; Brown, Simon G. A.; Currie, Bart J.; Halkidis, Lambros; Whitaker, Richard; Close, Benjamin; Isbister, Geoffrey K.
2012-01-01
Background Death adders (Acanthophis spp) are found in Australia, Papua New Guinea and parts of eastern Indonesia. This study aimed to investigate the clinical syndrome of death adder envenoming and response to antivenom treatment. Methodology/Principal Findings Definite death adder bites were recruited from the Australian Snakebite Project (ASP) as defined by expert identification or detection of death adder venom in blood. Clinical effects and laboratory results were collected prospectively, including the time course of neurotoxicity and response to treatment. Enzyme immunoassay was used to measure venom concentrations. Twenty nine patients had definite death adder bites; median age 45 yr (5–74 yr); 25 were male. Envenoming occurred in 14 patients. Two further patients had allergic reactions without envenoming, both snake handlers with previous death adder bites. Of 14 envenomed patients, 12 developed neurotoxicity characterised by ptosis (12), diplopia (9), bulbar weakness (7), intercostal muscle weakness (2) and limb weakness (2). Intubation and mechanical ventilation were required for two patients for 17 and 83 hours. The median time to onset of neurotoxicity was 4 hours (0.5–15.5 hr). One patient bitten by a northern death adder developed myotoxicity and one patient only developed systemic symptoms without neurotoxicity. No patient developed venom induced consumption coagulopathy. Antivenom was administered to 13 patients, all receiving one vial initially. The median time for resolution of neurotoxicity post-antivenom was 21 hours (5–168). The median peak venom concentration in 13 envenomed patients with blood samples was 22 ng/mL (4.4–245 ng/mL). In eight patients where post-antivenom bloods were available, no venom was detected after one vial of antivenom. Conclusions/Significance Death adder envenoming is characterised by neurotoxicity, which is mild in most cases. One vial of death adder antivenom was sufficient to bind all circulating venom. The persistent neurological effects despite antivenom, suggests that neurotoxicity is not reversed by antivenom. PMID:23029595
Johnston, Christopher I; O'Leary, Margaret A; Brown, Simon G A; Currie, Bart J; Halkidis, Lambros; Whitaker, Richard; Close, Benjamin; Isbister, Geoffrey K
2012-01-01
Death adders (Acanthophis spp) are found in Australia, Papua New Guinea and parts of eastern Indonesia. This study aimed to investigate the clinical syndrome of death adder envenoming and response to antivenom treatment. Definite death adder bites were recruited from the Australian Snakebite Project (ASP) as defined by expert identification or detection of death adder venom in blood. Clinical effects and laboratory results were collected prospectively, including the time course of neurotoxicity and response to treatment. Enzyme immunoassay was used to measure venom concentrations. Twenty nine patients had definite death adder bites; median age 45 yr (5-74 yr); 25 were male. Envenoming occurred in 14 patients. Two further patients had allergic reactions without envenoming, both snake handlers with previous death adder bites. Of 14 envenomed patients, 12 developed neurotoxicity characterised by ptosis (12), diplopia (9), bulbar weakness (7), intercostal muscle weakness (2) and limb weakness (2). Intubation and mechanical ventilation were required for two patients for 17 and 83 hours. The median time to onset of neurotoxicity was 4 hours (0.5-15.5 hr). One patient bitten by a northern death adder developed myotoxicity and one patient only developed systemic symptoms without neurotoxicity. No patient developed venom induced consumption coagulopathy. Antivenom was administered to 13 patients, all receiving one vial initially. The median time for resolution of neurotoxicity post-antivenom was 21 hours (5-168). The median peak venom concentration in 13 envenomed patients with blood samples was 22 ng/mL (4.4-245 ng/mL). In eight patients where post-antivenom bloods were available, no venom was detected after one vial of antivenom. Death adder envenoming is characterised by neurotoxicity, which is mild in most cases. One vial of death adder antivenom was sufficient to bind all circulating venom. The persistent neurological effects despite antivenom, suggests that neurotoxicity is not reversed by antivenom.
Study of the Effect of Hydrocarbon Type Biodegradation on Fuel Specification Properties
2014-06-01
helped to optimize conditions or uncovered some experimental problems and will not be discussed in the results section of this report. For example...bottles 12/23/2013 * experimental results suspect due to evaporation or other fuel loss 22 3.3 Vial experiments...F76 experimental results are provided in Table 78 79 22. In both experiments, Acinetobacter is creating significant degradation of the normal
Magnetic Susceptibility as a B0 Field Strength Independent MRI Biomarker of Liver Iron Overload
Hernando, Diego; Cook, Rachel J.; Diamond, Carol; Reeder, Scott B.
2013-01-01
Purpose MR-based quantification of liver magnetic susceptibility may enable field strength-independent measurement of liver iron concentration (LIC). However, susceptibility quantification is challenging, due to non-local effects of susceptibility on the B0 field. The purpose of this work is to demonstrate feasibility of susceptibility-based LIC quantification using a fat-referenced approach. Methods Phantoms consisting of vials with increasing iron concentrations immersed between oil/water layers, and twenty-seven subjects (9 controls/18 subjects with liver iron overload) were scanned. Ferriscan (1.5T) provided R2-based reference LIC. Multi-echo 3D-SPGR (1.5T/3T) enabled fat-water, B0- and R2*-mapping. Phantom iron concentration (mg Fe/l) was estimated from B0 differences (ΔB0) between vials and neighboring oil. Liver susceptibility and LIC (mg Fe/g dry tissue) was estimated from ΔB0 between the lateral right lobe of the liver and adjacent subcutaneous adipose tissue (SAT). Results Estimated phantom iron concentrations had good correlation with true iron concentrations (1.5T:slope=0.86, intercept=0.72, r2=0.98; 3T:slope=0.85, intercept=1.73, r2=0.98). In liver, ΔB0 correlated strongly with R2* (1.5T:r2=0.86; 3T:r2=0.93) and B0-LIC had good agreement with Ferriscan-LIC (slopes/intercepts nearly 1.0/0.0, 1.5T:r2=0.67, slope=0.93±0.13, p≈0.50, intercept=1.93±0.78, p≈0.02; 3T:r2=0.84, slope=1.01±0.09, p≈0.90, intercept=0.23±0.52, p≈0.68). Discussion Fat-referenced, susceptibility-based LIC estimation is feasible at both field strengths. This approach may enable improved susceptibility mapping in the abdomen. PMID:23801540
Simple, field portable colorimetric detection device for organic peroxides and hydrogen peroxide
Pagoria, Philip F.; Mitchell, Alexander R.; Whipple, Richard E.; Carman, M. Leslie; Reynolds, John G.; Nunes, Peter; Shields, Sharon J.
2010-11-09
A simple and effective system for the colorimetric determination of organic peroxides and hydrogen peroxide. A peroxide pen utilizing a swipe material attached to a polyethylene tube contains two crushable vials. The two crushable vials contain a colorimetric reagent separated into dry ingredients and liquid ingredients. After swiping a suspected substance or surface the vials are broken, the reagent is mixed thoroughly and the reagent is allowed to wick into the swipe material. The presence of organic peroxides or hydrogen peroxide is confirmed by a deep blue color.
Sharma, Megha; Gautam, Vikas; Mahajan, Monika; Rana, Sudesh; Majumdar, Manasi; Ray, Pallab
2017-10-01
Culture-negative bacteraemia has been an enigmatic entity with respect to its aetiological agents. In an attempt to actively identify those positive blood cultures that escape isolation and detection on routine workflow, an additional step of MALDI-TOF MS (matrix-assisted laser desorption ionization-time of flight mass spectrometry) based detection was carried out directly from the flagged blood culture bottles. Blood samples from 200 blood culture bottles that beeped positive with automated (BACTEC) system and showed no growth of organism on routine culture media, were subjected to analysis by MALDI-TOF MS. Forty seven of the 200 (23.5%) bacterial aetiology could be established by bottle-based method. Based on these results, growth on culture medium could be achieved for the isolates by providing special growth conditions to the fastidious organisms. Direct identification by MALDI-TOF MS from BACTEC-positive bottles provided an opportunity to isolate those fastidious organisms that failed to grow on routine culture medium by providing them with necessary alterations in growth environment.
Feutry, Frédéric; Simon, Nicolas; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Décaudin, Bertrand; Labalette, Pierre; Odou, Pascal
2016-01-01
Injecting intracameral cefuroxime has been found beneficial in reducing the risk of postoperative endophthalmitis but its use has been limited through a lack of approved marketing and of ready-to-use single-units as well as the problem of aseptic compounding. Our aim was to assess a new automated primary packaging system which should ensure a higher level of sterility, thanks to its closed, sterile, ready-to-use polymer vial called "Crystal® vial". The chemical stability of a 10 mg/mL cefuroxime solution was compared in 1 mL Crystal® vials and 1 mL Luer-lock polypropylene syringes (actual reference) to eliminate any potential and specific interactions with its cyclic olefin copolymer (COC) body and elastomer stopper. Cefuroxime solution was introduced into vials and syringes and stored at -20 °C, +5 °C and +25°C/60% Relative Humidity. Cefuroxime concentration and the relative amount of the main degradation product (descarbamoyl-cefuroxime) were both determined by an HPLC/UV method indicating stability. Solutions were considered steady if the concentration remained at over 90% of the initial value. In the adapted storage conditions, the evolution of osmolality, pH and sterility was assessed. Stability profiles were identical between vials and syringes in all storage and temperature conditions. The solution was stable (cefuroxime concentration, pH and osmolality) and still sterile for 365 days at -20°C. The concentration fell below 90% after 21 days at +5 °C and after 16 h at +25°C/60%s relative humidity. The COC and thermoplastic elastomer of the vials had no impact on the degradation process confirming its possible use for a ready-to-use cefuroxime solution single-unit dose.
Thantsha, M S; Labuschagne, P W; Mamvura, C I
2014-02-01
The probiotic industry faces the challenge of retention of probiotic culture viability as numbers of these cells within their products inevitably decrease over time. In order to retain probiotic viability levels above the therapeutic minimum over the duration of the product's shelf life, various methods have been employed, among which encapsulation has received much interest. In line with exploitation of encapsulation for protection of probiotics against adverse conditions, we have previously encapsulated bifidobacteria in poly-(vinylpyrrolidone)-poly-(vinylacetate-co-crotonic acid) (PVP:PVAc-CA) interpolymer complex microparticles under supercritical conditions. The microparticles produced had suitable characteristics for food applications and also protected the bacteria in simulated gastrointestinal fluids. The current study reports on accelerated shelf life studies of PVP:PVAc-CA encapsulated Bifidobacterium lactis Bb12 and Bifidobacterium longum Bb46. Samples were stored as free powders in glass vials at 30 °C for 12 weeks and then analysed for viable counts and water activity levels weekly or fortnightly. Water activities of the samples were within the range of 0.25-0.43, with an average a(w) = 0.34, throughout the storage period. PVP:PVAc-CA interpolymer complex encapsulation retained viable levels above the recommended minimum for 10 and 12 weeks, for B. longum Bb46 and B. lactis Bb12, respectively, thereby extending their shelf lives under high storage temperature by between 4 and 7 weeks. These results reveal the possibility for manufacture of encapsulated probiotic powders with increased stability at ambient temperatures. This would potentially allow the supply of a stable probiotic formulation to impoverished communities without proper storage facilities recommended for most of the currently available commercial probiotic products.
Sinha, Madhumita; Quan, Dan; McDonald, Fred W; Valdez, André
2016-12-01
Scorpion antivenom was recently approved for use in patients with clinically significant scorpion envenomation in the United States; no formal economic analysis on its impact on cost of management has been performed. Three different strategies of management of scorpion envenomation with systemic neurotoxic symptoms in children were compared for cost minimization from a societal perspective. In strategy I, patients were managed with supportive care only without antivenom. In strategy II, an aggressive strategy of full-dose antivenom (initial dose of 3 vials with the use of additional vials administered 1 vial at a time) was considered. In strategy III, a single-vial serial antivenom dosing strategy titrated to clinical response was considered. Clinical probabilities for the different strategies were obtained from retrospective review of medical records of patients with scorpion envenomation over a 10-year period at our institution. Baseline cost values were obtained from patient reimbursement data from our institution. In baseline analysis, strategy I of supportive care only with no antivenom was least costly at US $3466.50/patient. Strategy III of single-vial serial dosing was intermediate but less expensive than strategy II of full-dose antivenom, with an incremental cost of US $3171.08 per patient. In a 1-way sensitivity analysis, at a threshold antivenom cost of US $1577.87, strategy III of single-vial serial dosing became the least costly strategy. For children with scorpion envenomation, use of a management strategy based on serial dosing of antivenom titrated to clinical response is less costly than a strategy of initial use of full-dose antivenom.
Particulate Study on NeoProfen, a Neonatal Injectable Product.
Krishna, Aravind; Rice, Michael; Kester, Tom; Waters, Michael; Wilson, Terry
2016-01-01
NeoProfen or sterile ibuprofen L-lysine at 10 mg/mL ibuprofen, in 2 mL single-use Type I glass vials is often a first choice medication used to close a patent ductus arteriosus in neonatal patients from 500 to 1500 g body weight. Visible particulate matter was found in vials that were placed on a commercial stability program prior to the approved expiration date of 2 years. A combination of instrumental techniques including inductively coupled plasma-mass spectrometry, x-ray photoelectron spectroscopy, scanning electron microscopy energy dispersive x-ray spectrometry, and Raman and Fourier transform infrared microspectroscopy was used to evaluate stability, pilot batch and packaging samples in a root cause investigation. The particulate matter was shown to consist largely of ibuprofen aluminum salts of various stoichiometries. It developed over time by a substitution mechanism, in which the ibuprofen anion in solution reacts with the aluminum oxide network of the borosilicate glass giving the ibuprofen aluminum salt with =Al-OH remaining in the network. For corrective action an alternate Type I borosilicate glass vial with interior coating, not found in the original vial, was chosen for the product to prevent this occurrence. NeoProfen (sterile preservative-free ibuprofin L-lysine at 17 mg/mL in a single-use glass vial) is used to close a clinically significant patent ductus arteriosus in premature infants no more than 32 weeks gestational age. The neonatal population is especially sensitive to outside chemical, physical and environmental conditions because of incompletely developed organ systems, low birth weight and other underlying conditions. Two batches of this product were voluntarily recalled by the manufacturer, Lundbeck, and investigated for the source of particulate matter observed during a commercial stability testing program. This was found to result from an interaction between the product and the Type I borosilicate glass vial where ibuprofen substitutes for the aluminum oxide network in the glass, forming an ibuprofen aluminum hydroxide salt as particulate. In order to prevent this salt formation an alternate glass vial was chosen which had interiors treated using a chemical vapor deposition technique. These vials were found to preserve NeoProfen quality properties during short term stress and medium term stability studies. © PDA, Inc. 2016.
Stability of Bortezomib 2.5 mg/mL in Vials and Syringes Stored at 4°C and Room Temperature (23°C)
Walker, Scott E; Charbonneau, Lauren F; Law, Shirley
2014-01-01
Background: Solutions of bortezomib 1.0 mg/mL for IV administration are reportedly stable for up to 42 days. Recent publications have reported that the safety profile of bortezomib is better with subcutaneous administration than with IV administration. Objective: To evaluate the stability of higher-concentration bortezomib solutions for subcutaneous administration (i.e., 2.5 mg/mL in 0.9% sodium chloride [normal saline or NS]). Methods: On study day 0, twelve 3.5-mg vials of powdered bortezomib were each reconstituted with 1.4 mL of NS to prepare solutions with concentration 2.5 mg/mL. Half of the solutions were subsequently stored in the original vials and half were transferred to syringes. Three of each type of container were stored in the refrigerator (4°C) and the other 3 of each type were stored at room temperature (23°C). Concentration analysis and physical inspection were completed on study days 0, 1, 2, 8, 12, 14, 19, and 21. The concentration of bortezomib was determined by a validated liquid chromatographic method with ultraviolet detection. The expiry date was determined according to the time to achieve 90% of the initial concentration, based on the fastest degradation rate calculated from the 95% confidence interval of the observed degradation rate. Results: The analytical method separated degradation products from bortezomib such that the concentration was measured specifically and accurately (with absolute deviations from known concentration averaging 2.99%), with intraday and interday reproducibility averaging 1.51% and 2.51%, respectively. During the study period, all solutions were observed to retain at least 95.26% of the initial concentration in both types of containers at both temperatures. Conclusions: Bortezomib (3.5 mg in manufacturer’s vial) reconstituted with 1.4 mL NS is physically and chemically stable for up to 21 days at 4°C or 23°C when stored in either the manufacturer’s original glass vial or a syringe. Subcutaneous injection of bortezomib represents a change in practice, and there is a potential safety concern if a solution of the increased concentration used for subcutaneous administration (2.5 mg/mL) is inadvertently used to prepare a dose intended for IV administration. Therefore, it is recommended that sites switching to subcutaneous administration of bortezomib eliminate 1.0 mg/mL IV solutions altogether or institute substantial barriers to prevent IV administration of the higher concentration of bortezomib. PMID:24799719
Modelling Ferroelectric Nanoparticles in Nematic Liquid Crystals (FERNANO)
2015-02-26
DIPARTIMENTO DI CHIMICA FISICA ED INORGANICA VIALE DEL RISORGIMENTO 4 BOLOGNA, 40136 ITALY EOARD GRANT #FA8655-11-1-3046 Report...AND ADDRESS(ES) DIPARTIMENTO DI CHIMICA FISICA ED INORGANICA VIALE DEL RISORGIMENTO 4 BOLOGNA, 40136 ITALY 8. PERFORMING ORGANIZATION
Martins, E W; Potiens, M P A
2012-07-01
This paper presents the establishment of a quality control program and correction factors for the geometry of the vials used for distribution of radiopharmaceutical and activimeters calibration. The radiopharmaceutical produced by IPEN 67Ga, 131I, 201Tl and 99mTc had been tested using two different vials. Results show a maximum variation of 22% for 201Tl, and the minimum variation was 2.98% for 131I. The correction factors must be incorporated in the routine calibration of the activimeters. Copyright © 2011 Elsevier Ltd. All rights reserved.
Pisano, Roberto; Fissore, Davide; Barresi, Antonello A; Brayard, Philippe; Chouvenc, Pierre; Woinet, Bertrand
2013-02-01
This paper shows how to optimize the primary drying phase, for both product quality and drying time, of a parenteral formulation via design space. A non-steady state model, parameterized with experimentally determined heat and mass transfer coefficients, is used to define the design space when the heat transfer coefficient varies with the position of the vial in the array. The calculations recognize both equipment and product constraints, and also take into account model parameter uncertainty. Examples are given of cycles designed for the same formulation, but varying the freezing conditions and the freeze-dryer scale. These are then compared in terms of drying time. Furthermore, the impact of inter-vial variability on design space, and therefore on the optimized cycle, is addressed. With this regard, a simplified method is presented for the cycle design, which reduces the experimental effort required for the system qualification. The use of mathematical modeling is demonstrated to be very effective not only for cycle development, but also for solving problem of process transfer. This study showed that inter-vial variability remains significant when vials are loaded on plastic trays, and how inter-vial variability can be taken into account during process design.
Noncontact Infrared-Mediated Heat Transfer During Continuous Freeze-Drying of Unit Doses.
Van Bockstal, Pieter-Jan; De Meyer, Laurens; Corver, Jos; Vervaet, Chris; De Beer, Thomas
2017-01-01
Recently, an innovative continuous freeze-drying concept for unit doses was proposed, based on spinning the vials during freezing. An efficient heat transfer during drying is essential to continuously process these spin frozen vials. Therefore, the applicability of noncontact infrared (IR) radiation was examined. The impact of several process and formulation variables on the mass of sublimed ice after 15 min of primary drying (i.e., sublimation rate) and the total drying time was examined. Two experimental designs were performed in which electrical power to the IR heaters, distance between the IR heaters and the spin frozen vial, chamber pressure, product layer thickness, and 5 model formulations were included as factors. A near-infrared spectroscopy method was developed to determine the end point of primary and secondary drying. The sublimation rate was mainly influenced by the electrical power to the IR heaters and the distance between the IR heaters and the vial. The layer thickness had the largest effect on total drying time. The chamber pressure and the 5 model formulations had no significant impact on sublimation rate and total drying time, respectively. This study shows that IR radiation is suitable to provide the energy during the continuous processing of spin frozen vials. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Qureshi, Zaina P; Norris, Leann; Sartor, Oliver; McKoy, June M; Armstrong, John; Raisch, Dennis W; Garg, Vishvas; Stafkey-Mailey, Dana; Bennett, Charles Lee
2012-03-01
Counterfeit pharmaceuticals pose risks domestically. Because of their cost, cancer pharmaceuticals are vulnerable. We review findings from a domestic counterfeiting episode involving erythropoietin and outline anticounterfeiting recommendations for policy makers, patients, and health care professionals. Information was obtained on patients who received counterfeit erythropoietin, its distribution, and criminal investigations into counterfeiting networks. Interview sources included a physician, an attorney, employees of the Florida Department of Health and Human Services and the US Food and Drug Administration's (FDA) Office of Criminal Investigation, manufacturers, and wholesalers. Other sources included the book "Dangerous Doses," LexisNexis (search terms "counterfeit" and "erythropoietin") and the FDA database. Counterfeit product consisted of 2,000 U vials with counterfeit labels denoting 40,000 U. The counterfeiters, in collaboration with a Miami pharmacy, purchased 110,000 erythropoietin 2,000 U vials and affixed counterfeit labels to each vial. Products were then sold via the pharmaceutical "gray market" to wholesalers, then pharmacy chains. Investigations by Florida government officials implicated 17 persons, all of whom were found guilty of trafficking in counterfeit pharmaceuticals. Despite the large size of the operation, the FDA received reports of only 12 patients who had received counterfeit erythropoietin and detailed information for only two individuals. A 17-year-old liver transplant recipient and a 61-year-old patient with breast cancer experienced loss of efficacy after receiving counterfeit erythropoietin. Wider use of FDA anticounterfeit initiatives, limiting pharmaceutical suppliers to reputable distributors, and educating providers and patients about signs of counterfeit drugs can improve the safety of cancer pharmaceuticals.
Implementation of an i.v.-compounding robot in a hospital-based cancer center pharmacy.
Yaniv, Angela W; Knoer, Scott J
2013-11-15
The implementation of a robotic device for compounding patient-specific chemotherapy doses is described, including a review of data on the robot's performance over a 13-month period. The automated system prepares individualized i.v. chemotherapy doses in a variety of infusion bags and syringes; more than 50 drugs are validated for use in the machine. The robot is programmed to recognize the physical parameters of syringes and vials and uses photographic identification, barcode identification, and gravimetric measurements to ensure that the correct ingredients are compounded and the final dose is accurate. The implementation timeline, including site preparation, logistics planning, installation, calibration, staff training, development of a pharmacy information system (PIS) interface, and validation by the state board of pharmacy, was about 10 months. In its first 13 months of operation, the robot was used to prepare 7384 medication doses; 85 doses (1.2%) found to be outside the desired accuracy range (±4%) were manually modified by pharmacy staff. Ongoing system monitoring has identified mechanical and materials-related problems including vial-recognition failures (in many instances, these issues were resolved by the system operator and robotic compounding proceeded successfully), interface issues affecting robot-PIS communication, and human errors such as the loading of an incorrect vial or bag into the machine. Through staff training, information technology improvements, and workflow adjustments, the robot's throughput has been steadily improved. An i.v.-compounding robot was successfully implemented in a cancer center pharmacy. The robot performs compounding tasks safely and accurately and has been integrated into the pharmacy's workflow.
Household experience and costs of seeking measles vaccination in rural Guinea-Bissau.
Byberg, S; Fisker, A B; Rodrigues, A; Balde, I; Enemark, U; Aaby, P; Benn, C S; Griffiths, U K
2017-01-01
Children younger than 12 months of age are eligible for childhood vaccines through the public health system in Guinea-Bissau. To limit open vial wastage, a restrictive vial opening policy has been implemented; 10-dose measles vaccine vials are only opened if six or more children aged 9-11 months are present at the vaccination post. Consequently, mothers who bring their child for measles vaccination can be told to return another day. We aimed to describe the household experience and estimate household costs of seeking measles vaccination in rural Guinea-Bissau. Within a national sample of village clusters under demographic surveillance, we interviewed mothers of children aged 9-21 months about their experience with seeking measles vaccination. From information about time and money spent, we calculated household costs of seeking measles vaccination. We interviewed mothers of 1308 children of whom 1043 (80%) had sought measles vaccination at least once. Measles vaccination coverage was 70% (910/1308). Coverage decreased with increasing distance to the health centre. On average, mothers who had taken their child for vaccination took their child 1.4 times. Mean costs of achieving 70% coverage were 2.04 USD (SD 3.86) per child taken for vaccination. Half of the mothers spent more than 2 h seeking vaccination and 11% spent money on transportation. We found several indications of missed opportunities for measles vaccination resulting in suboptimal coverage. The household costs comprised 3.3% of the average monthly income and should be taken into account when assessing the costs of delivering vaccinations. © 2016 John Wiley & Sons Ltd.
van Boxtel, Niels; Wolfs, Kris; Palacín, Marta Guillén; Van Schepdael, Ann; Adams, Erwin
2016-12-09
The analysis of quaternary ammonium salts (QAS) using GC is often performed by "in injector" pyrolysis to create volatile degradation products for quantification purposes. Besides the risk of severe system contamination, the application of this approach on aqueous samples is problematic. In this work, the sample is treated in a vial with 2,2-dimethoxypropane (DMP) under acidic catalysis. In addition to the removal of water and sample enrichment, the QAS are decomposed. As HS transfers only volatile compounds to the GC system, contamination is avoided. It was found that depending on the presence of benzyl, phenyl or methyl groups on the quaternary nitrogen; benzyl chloride, N,N-dimethylaniline or chloromethane are formed respectively in the sealed vial. All these can be used as an analytical target. A calibration curve for benzyl chloride could be derived from the pure compound. Chloromethane was generated from pure benzyldimethyldecylammonium chloride (BEDIDE), a pure QAS with benzyl and methyl groups, to construct a secondary calibration curve using a back analysis approach. It has been proven that by quantifying the formed analytical targets, the mass balance for the QAS under investigation was close to 100%. The presented procedure allows the quantification of any aromatic substituted QAS without the need for a matching reference, which is a major advantage over existing CE and LC methods The proposed methodology was validated for mouth sprays containing benzethonium chloride (BZTCl) or benzoxonium chloride (BZOCl) and for denatonium benzoate (DB) in ethylene glycol (EG) based cooling liquids. Results showed that the approach provided excellent linearity (R 2 ≥0.999) and limits of detection around 0.01μg/vial for benzyl chloride. It was found that the reaction product of DMP and glycerol which was also present in the mouthspray and some cooling liquids, caused chromatographic interference with benzyl chloride. Treating those samples in the vial with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) after the enrichment step removes the interference and leaves a possible pathway for the simultaneous determination of glycerol in those samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Williams, Kristie L; Woslager, Megan; Garland, Stephanie L; Barton, Roger P; Banner, William
2017-06-01
Western Pygmy Rattlesnake (WPR) envenomation reportedly causes refractory and persistent coagulopathy when treated with CroFab ® (Crotalidae Polyvalent Immune Fab). We report two cases where polyvalent equine anti-viper serum (AntivipmynTRI ® ) was used to treat recurrent coagulopathy in children. The first patient was a 16-month-old male who was bitten by a confirmed WPR. The patient received a total of 18 vials of CroFab ® . His labs normalized, swelling gradually improved, and the child was discharged to home. On day 5, the child returned to the emergency department with a great deal of inguinal tenderness. Labs were obtained and the child's INR was >13.1, while the fibrinogen was <60 mg/dL and the d-dimer was 11.72 mg/L. A decision was made to administer Antivipmyn TRI ® , and the child received a total of 10 vials. Lab values significantly improved: INR 1.2, fibrinogen 93 mg/dL, and d-dimer 4.21 mg/L. The second patient was a 20-month-old male who presented following snake envenomation. The child was administered a total of 22 vials of CroFab ® over approximately 70 h following envenomation. Physical exam continued to improve, however, lab results showed an increasing INR 1.98, decreasing platelet count 124 × 10 3 per μL, fibrinogen <60 mg/dL, and d-dimer >20 ug/mL. A total of 15 vials of Antivipmyn TRI ® were administered to this patient. Following this administration, labs and clinical exam both significantly improved. Labs revealed INR 1.16, fibrinogen 110 mg/dL, d-dimer 3.2 mg/L and platelet count 215 × 10 3 /μL. CroFab ® is still the first-line treatment for children bitten by a WPR, but in some cases patients develop a recurrent coagulopathy. The rapid response demonstrated by Antivipmyn TRI ® leads us to conclude that this is a potential therapy for this clinical situation.
Zheng, Yumin; Ji, Shundong; Tomaselli, Elena; Liu, Shuang
2014-07-01
The objective of this study was to develop a kit formulation for [(99m) TcN(mpo)(PNP5)](+) (MPO = 2-mercaptopyridine oxide), ((99m) TcN-MPO) to support its clinical evaluations as a SPECT radiotracer. Radiolabeling studies were performed using three different formulations (two-vial formulation and single-vial formulations with/without SnCl2 ) to explore the factors influencing radiochemical purity (RCP) of (99m) TcN-MPO. We found that the most important factor affecting the RCP of (99m) TcN-MPO was the purity of PNP5. (99m) TcN-MPO was prepared >98% RCP (n = 20) using the two-vial formulation. For single-vial formulations with/without SnCl2 , β-cyclodextrin (β-CD) is particularly useful as a stabilizer for PNP5. The RCP of (99m) TcN-MPO was 95-98% using β-CD, but its RCP was only 90-93% with γ-cyclodextrin (γ-CD). It seems that PNP5 fits better into the inner cavity of β-CD, which forms more stable inclusion complex than γ-CD in the single-vial formulations. The results from biodistribution and imaging studies in Sprague-Dawley rats clearly demonstrated biological equivalence of three different formulations. Single photon-emission computed tomography data suggested that high quality images could be obtained at 0-30-min post-injection without significant interference from the liver radioactivity. Considering the ease for (99m) Tc-labeling and high RCP of (99m) TcN-MPO, the non-SnCl2 single-vial formulation is an attractive choice for future clinical studies. Copyright © 2014 John Wiley & Sons, Ltd.
Thermal In-Pouch Microwave Sterilization
2011-06-30
dynamic range, ’ precision, ■ accuracy, ’ recovery (function of the amount of yogurt added to vial), ■ specificity (TOO Page-24 Quarterly...8217 accuracy, ■ recovery (function of the amount of yogurt added to vial). specificity (TOO Page-24 Quarterly Report For the Period Ending 30 June
Preservation of soil samples for the analysis of volatile organic compounds (VOCs) requires both the inhibition of VOC degradation and the restriction of vapor movement in or out of the sample container. Clear, 40,mL glass VOA vials manufactured by the four major U.S. glass manu...
Seike, Yasushi; Fukumori, Ryoko; Senga, Yukiko; Oka, Hiroki; Fujinaga, Kaoru; Okumura, Minoru
2004-01-01
A new and simple method for the determination of hydroxylamine in environmental water, such as fresh rivers and lakes using hypochlorite, followed by its gas choromatographic detection, has been developed. A glass vial filled with sample water was sealed by a butyl-rubber stopper and aluminum cap without head-space, and then sodium hypochlorite solution was injected into the vial through a syringe to convert hydroxylamine to nitrous oxide. The head-space in the glass vial was prepared with 99.9% grade N2 using a gas-tight syringe. After the glass vial was shaken for a few minutes, nitrous oxide in the gas-phase was measured by a gas chromatograph with an electron-capture detector. The dissolved nitrous oxide in the liquid-phase was calculated according to the solubility formula. The proposed method was applied to the analysis of fresh-water samples taken from Iu river and Hii river, flowing into brackish Lakes Nakaumi and Shinji, respectively.
Replacing the Measles Ten-Dose Vaccine Presentation with the Single-Dose Presentation in Thailand
Lee, Bruce Y.; Assi, Tina-Marie; Rookkapan, Korngamon; Connor, Diana L.; Rajgopal, Jayant; Sornsrivichai, Vorasith; Brown, Shawn T.; Welling, Joel S.; Norman, Bryan A.; Chen, Sheng-I; Bailey, Rachel R.; Wiringa, Ann E.; Wateska, Angela R.; Jana, Anirban; Van Panhuis, Willem G.; Burke, Donald S.
2011-01-01
Introduced to minimize open vial wastage, single-dose vaccine vials require more storage space and therefore may affect vaccine supply chains (i.e., the series of steps and processes entailed to deliver vaccines from manufacturers to patients). We developed a computational model of Thailand’s Trang province vaccine supply chain to analyze the effects of switching from a ten-dose measles vaccine presentation to each of the following: a single-dose Measles-Mumps-Rubella vaccine (which Thailand is currently considering) and a single-dose measles vaccine. While the Trang province vaccine supply chain would generally have enough storage and transport capacity to accommodate the switches, the added volume could push some locations’ storage and transport space utilization close to their limits. Single-dose vaccines would allow for more precise ordering and decrease open vial waste, but decrease reserves for unanticipated demand. Moreover, the added disposal and administration costs could far outweigh the costs saved from preventing open vial wastage. PMID:21439313
Jarrahian, Courtney; Rein-Weston, Annie; Saxon, Gene; Creelman, Ben; Kachmarik, Greg; Anand, Abhijeet; Zehrung, Darin
2017-03-27
Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered. Copyright © 2017 PATH. Published by Elsevier Ltd.. All rights reserved.
APIC position paper: Safe injection, infusion, and medication vial practices in health care.
Dolan, Susan A; Arias, Kathleen Meehan; Felizardo, Gwen; Barnes, Sue; Kraska, Susan; Patrick, Marcia; Bumsted, Amelia
2016-07-01
The transmission of bloodborne viruses and other microbial pathogens to patients during routine health care procedures continues to occur because of the use of improper injection, infusion, medication vial, and point-of-care testing practices by health care personnel. These unsafe practices occur in various clinical settings and result in unacceptable and devastating events for patients. This document updates the Association for Professionals in Infection Control and Epidemiology 2010 position paper on safe injection, infusion, and medication vial practices in health care. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Advances in vaccine stability monitoring technology.
Zweig, Stephen E
2006-08-14
Electronic time-temperature indicator (eTTI) monitors can be programmed to exactly follow the stability characteristics of vaccines with a high degree of realism. The monitors have a visual output, enabling vaccine status to be assessed at a glance, and can also output more detailed statistical data. When packaged with vaccine vials in groups of about 10 vials per box, the eTTI can remain with a vaccine throughout most of the vaccine's lifetime. The monitors can detect essentially all cold-chain breaks, and can detect issues, such as inadvertent freezing, that are presently not detected by other vaccine stability monitors such as Vaccine Vial Monitors (VVM).
Abolaji, Amos Olalekan; Babalola, Oluwatoyin Victoria; Adegoke, Abimbola Kehinde; Farombi, Ebenezer Olatunde
2017-10-01
Trichloroethylene (TCE) is a chlorinated organic pollutant of groundwater with diverse toxic effects in animals and humans. Here, we investigated the ameliorative role of hesperidin, a citrus bioflavonoid on TCE-induced toxicity in Drosophila melanogaster. Four groups of D. melanogaster (50 flies/vial, with 5 vials/group) were exposed to ethanol (2.5%, control), HSP (400mg/10g diet), TCE (10μM/10g diet) and TCE (10μM/10g diet)+HSP (400mg/10g diet) respectively in the diet for 5days. Then, selected oxidative stress and antioxidant markers were evaluated. The results showed that TCE significantly increased the level of reactive oxygen species (ROS) and inhibited catalase, glutathione S-transferase and acetylcholinesterase (AChE) activities with concurrent depletion of total thiol level. However, co-administration of TCE and hesperidin mitigated TCE-induced depletion of antioxidants, and restored ROS level and AChE activity in the flies (p<0.05). Overall, hesperidin offered protective potency on TCE-induced oxidative stress in the flies via anti-oxidative mechanism. Copyright © 2017 Elsevier B.V. All rights reserved.
Hottot, A; Vessot, S; Andrieu, J
2005-01-01
The principal aim of this study was to evaluate the water vapour mass transfer resistance of the dried layer and the vial heat transfer coefficient values of a pharmaceutical product during the primary drying period. First, overall vial heat transfer coefficient values, Kv, were determined by a gravimetric method based on pure ice sublimation experiments. Thus, it was possible to set up a map of the total heat flux received by each vial throughout the plate surface of our pilot scale freeze-dryer. Important heterogeneities were observed for the vials placed at the plate edges and for the vials placed at the center of the plate. As well, the same gravimetric method was also used to precisely determine the influence of main lyophilization operating parameters (shelf temperature and gas total pressure) or the vial types and sizes on these overall heat transfer coefficient values. A semi-empirical relationship as a function of total gas pressure was proposed. The transient method by pressure rise analysis (PRA method) after interrupting the water vapour flow between the sublimation chamber and the condenser, previously set up and validated in our laboratory, was then extensively used with an amorphous BSA-based formulation to identify the dried layer mass transfer resistance values, Rp, the ice front temperature, and the total heat transfer coefficient values, Kv, with or without annealing treatment. It was proved that this method gave accurate and coherent data only during the first half of the sublimation period when the totality of the vials of the set was still sublimating. Thus, this rapid method allowed estimation of, on line and in situ, the sublimation front temperature and the characterization of the morphology and structure of the freeze-dried layer, all along the first part of the sublimation period. The estimated sublimation temperatures shown by the PRA model were about 2 degrees C lower than the experimental values obtained using thermocouples inserted inside the vial, in accordance with previous data given by this method for similar freeze-drying conditions. As well, by using this method we could confirm the homogenization of the dried layer porous structure by annealing treatment after the freezing step. Furthermore, frozen matrix structure analysis (mean pore diameter) using optical microscopy and mass transfer modelling of water vapour by molecular diffusion (Knudsen regime) allowed, in some cases, to predict the experimental values of this overall mass transfer resistance directly related to the freeze-dried cake permeability.
Shrivastava, Ashutosh; Gupta, Neeraj; Upadhyay, Pramod; Puliyel, Jacob
2012-04-01
Stabilized live attenuated oral polio vaccine (OPV) is used to immunize children up to the age of five years to prevent poliomyelitis. It is strongly advised that the cold-chain should be maintained until the vaccine is administered. It is assumed, that vaccine vial monitors (VVMs) are reliable at all temperatures. VVMs are tested at 37°C and it is assumed that the labels reach discard point before vaccine potency drops to >0.6 log10. This study was undertaken to see if VVMs were reliable when exposed to high temperatures as can occur in field conditions in India. Vaccine vials with VVMs were incubated (10 vials for each temperature) in an incubator at different temperatures at 37, 41, 45 and 49.5°C. Time-lapse photographs of the VVMs on vials were taken hourly to look for their discard-point. At 37 and 41°C the VVMs worked well. At 45°C, vaccine potency is known to drop to the discard level within 14 h whereas the VVM discard point was reached at 16 h. At 49.5°C the VVMs reached discard point at 9 h when these should have reached it at 3 h. Absolute reliance cannot be placed on VVM in situation where environmental temperatures are high. Caution is needed when using 'outside the cold chain' (OCC) protocols.
Höger, Kerstin; Mathes, Johannes; Frieß, Wolfgang
2015-01-01
In this study, the adsorption of an IgG1 antibody to siliconized vials was investigated with focus on the formulation parameters pH, ionic strength, and nonionic surfactants. Electrophoretic mobility measurements were performed to investigate the charge characteristics of protein and siliconized glass particles at different pH values. Calculation of the electrokinetic charge density allowed further insight into the energetic conditions in the protein-sorbent interface. Maximum adsorption of IgG1 was found at acidic pH values and could be correlated with energetically favorable minimal ion incorporation into the interface. The importance of electrostatic interactions for IgG1 adsorption at acidic pH values was also confirmed by the efficient adsorption reduction at decreased solution ionic strength. A second adsorption maximum around the pI of the protein was assigned to hydrophobic interactions with the siliconized surface. Addition of the nonionic surfactants poloxamer 188 or polysorbate 80 resulted in almost complete suppression of adsorption at pH 7.2, and a strong but less efficient effect at pH 4 on siliconized glass vials. This adsorption suppression was much less pronounced on borosilicate glass vials. From these results, it can be concluded that electrostatic interactions contribute substantially to IgG1 adsorption to siliconized glass vials especially at acidic formulation pH. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Hassan, Muhammad; Waheed, Muhammad Mohsin; Anjum, Muhammad Naeem
2016-01-01
To quantify the radiation dose enhancement in a human tissue-equivalent polymer gel impregnated with silver nanoparticles. The case-control study was conducted at the Bahawalpur Institute of Nuclear Medicine and Oncology, Bahawalpur, Pakistan, in January 2014. Silver nanoparticles used in this study were prepared by wet chemical method. Polymer gel was prepared by known quantity of gelatine, methacrylic acid, ascorbic acid, copper sulphate pentahydrate, hydroquinone and water. Different concentrations of silver nanoparticles were added to the gel during its cooling process. The gel was cooled in six plastic vials of 50ml each. Two vials were used as a control sample while four vials were impregnated with silver nanoparticles. After 22 hours, the vials were irradiated with gamma rays by aCobalt-60 unit. Radiation enhancement was assessed by taking magnetic resonance images of the vials. The images were analysed using Image J software. The dose enhancement factor was 24.17% and 40.49% for 5Gy and 10Gy dose respectively. The dose enhancement factor for the gel impregnated with 0.10mM silver nanoparticles was 32.88% and 51.98% for 5Gy and 10Gy dose respectively. The impregnation of a tissue-equivalent gel with silver nanoparticles resulted in dose enhancement and this effect was magnified up to a certain level with the increase in concentration of silver nanoparticles.
Qian, Qinfang; Venkataraman, Lata; Kirby, James E; Gold, Howard S; Yamazumi, Toshiaki
2010-04-01
We studied the utility of performing a penicillin binding protein 2a latex agglutination (PBP-LA) assay directly on Bactec blood culture broth samples containing Staphylococcus aureus to rapidly detect methicillin resistance. The sensitivity, specificity, positive predictive value, and negative predictive value of this method were 94.1%, 97.5%, 98%, and 92.9%, respectively.
Kim, Jae-Seok; Kang, Go-Eun; Kim, Han-Sung; Kim, Hyun Soo; Song, Wonkeun; Lee, Kyu Man
2016-01-01
The performance of molecular tests using the Verigene Gram-Positive and Gram-Negative Blood Culture nucleic acid tests (BC-GP and BC-GN, resp.; Naosphere, Northbrook, IL, USA) was evaluated for the identification of microorganisms detected from blood cultures. Ninety-nine blood cultures containing Gram-positive bacteria and 150 containing Gram-negative bacteria were analyzed using the BC-GP and BC-GN assays, respectively. Blood cultures were performed using the Bactec blood culture system (BD Diagnostic Systems, Franklin Lakes, NJ, USA) and conventional identification and antibiotic-susceptibility tests were performed using a MicroScan system (Siemens, West Sacramento, CA, USA). When a single strain of bacteria was isolated from the blood culture, Verigene assays correctly identified 97.9% (94/96) of Gram-positive bacteria and 93.8% (137/146) of Gram-negative bacteria. Resistance genes mecA and vanA were correctly detected by the BC-GP assay, while the extended-spectrum β-lactamase CTX-M and the carbapenemase OXA resistance gene were detected from 30 cases cultures by the BC-GN assay. The BC-GP and BC-GN assays showed high agreement with conventional identification and susceptibility tests. These tests are useful for rapid identification of microorganisms and the detection of clinically important resistance genes from positive Bactec blood cultures.
Torkaman Asadi, Fatemeh; Hashemi, Seyyed Hamid; Alikhani, Mohammad Yousef; Moghimbeigi, Abbas; Naseri, Zahra
2017-05-24
Current drug regimens for brucellosis are associated with relatively high rates of therapeutic failure or relapse. Reduced antimicrobial susceptibility of Brucella spp. has been proposed recently as a potential cause of therapeutic failure. The aim of this study was to evaluate the antibiotic resistance pattern of Brucella melitensis clinical isolates by E-test method in Hamadan, west of Iran. In a 15-month period, all patients with suspected brucellosis were enrolled. Blood specimens were collected for diagnosis of brucellosis by BACTEC system and serological tests. Antimicrobial susceptibility of clinical isolates to 7 antibiotics was assessed by the E-test method. One hundred forty-nine patients with brucellosis were evaluated. 38.3% of cultures of clinical samples were positive for BACTEC system, of which 91.2% were associated with a positive serological test result. No significant associations were found between serology and the culture method. All Brucella isolates were susceptible to doxycycline, streptomycin, gentamicin, ciprofloxacin, and moxifloxacin. However, decreased sensitivity to rifampin and trimethoprim-sulfamethoxazole was found in 35.1% and 3.5% of isolates, respectively. Because of the high rates of intermediate sensitivity to rifampin among Brucella isolates, this drug should be prescribed with caution. We recommend restricting the use of rifampin for treatment of brucellosis except as an alternative drug for special situations.
Devaux, Guy
2016-03-01
We study a series of exchanged original letters between the Parisian pharmacist art lover Émile Vial (1833-1917) and the Dutch painter Johan-Barthold Jongkind (1819 - 1891) from april 13th, 1876 till February 1th, 1887.
Nogier, Cyril; Hanlon, Patrick; Wiedenmayer, Karin; Maire, Nicolas
2015-03-01
A compact pre-filled auto-disable injection (cPAD) presentation is being developed for the fully liquid pentavalent DTP-HepB-Hib vaccine. A cost analysis (CA) to compare this presentation with the presently used single-dose vial (SDV) and multi-dose vial (MDV) was conducted in Cambodia, Ghana, and Peru. The CA included the development of an excel-based costing model and considered the costs of vaccine, safe injection equipment, procurement, storage, transport and distribution, vaccine administration by health staff, medical waste management, start-up activities, as well as coverage, birth cohort, vaccine, and safe injection equipment wastage rates. The outcome was the change in cost per pentavalent fully immunized child (PFIC) for a switch to cPAD. Field visits to health facilities, and interviews with key informants from immunization services and regulatory authorities, were conducted to collect data and to test the costing model in country context. Cost data were also obtained from manufacturers, published price lists, and author estimates. A sensitivity analysis (SA) was conducted to explore possible variations in values of data collected. Based on vaccine price trends estimated for 2016, cPAD is less costly in Ghana [incremental cost per PFIC: $US-0.59 (-6.46 %)] than the current presentation (ten-dose MDV) and in Peru (SDV): $US-0.89 (-7.14 %). In Cambodia, cPAD is more costly than SDV: $US+0.33 (+3.90 %). The most significant cost item per PFIC is the vaccine (reflecting wastage rates) in all presentations. The dominance of the vaccine price per dose and, to a lesser extent, the wastage rates in the incremental cost per PFIC show potential to simplify future analyses. Other relevant considerations at country level for a change of presentation include the potential for improved safety with cPAD, planned introduction of other vaccines, environmental and safety issues, and financial sustainability.
APIC position paper: safe injection, infusion, and medication vial practices in health care.
Dolan, Susan A; Felizardo, Gwenda; Barnes, Sue; Cox, Tracy R; Patrick, Marcia; Ward, Katherine S; Arias, Kathleen Meehan
2010-04-01
Outbreaks involving the transmission of bloodborne pathogens or other microbial pathogens to patients in various types of health care settings due to unsafe injection, infusion, and medication vial practices are unacceptable. Each of the outbreaks could have been prevented by the use of proper aseptic technique in conjunction with basic infection prevention practices for handling parenteral medications, administration of injections, and procurement and sampling of blood. This document provides practice guidance for health care facilities on essential safe injection, infusion, and vial practices that should be consistently implemented in such settings. 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Ashford, D A; Kellerman, S; Yakrus, M; Brim, S; Good, R C; Finelli, L; Jarvis, W R; McNeil, M M
1997-01-01
Between April and December 1994, 23 blood cultures from human immunodeficiency virus-infected patients grew rapidly growing mycobacteria suspected to be Mycobacterium chelonae at a hospital in New Jersey. The isolates were later identified as M. abscessus. Several bacterial species, including M. abscessus, were cultured from an opened multidose supplement vial (BBL Septi-Chek AFB Supplement) that had been used for mycobacterial blood cultures. The M. abscessus isolates from case patients and the supplement vial had identical multilocus enzyme electrophoresis and antimicrobial susceptibility patterns. Finding a contaminated vial of supplement, together with the lack of a distinct syndrome in case patients, was consistent with a pseudo-outbreak. PMID:9230377
Pham, Cau D.; Gade, Lalitha; Iqbal, Naureen; Scheel, Christina M.; Cleveland, Angela A.; Whitney, Anne M.; Noble-Wang, Judith; Chiller, Tom M.; Park, Benjamin J.; Litvintseva, Anastasia P.; Brandt, Mary E.
2013-01-01
In September 2012, the Centers for Disease Control and Prevention (CDC) initiated an outbreak investigation of fungal infections linked to injection of contaminated methylprednisolone acetate (MPA). Between 2 October 2012 and 14 February 2013, the CDC laboratory received 799 fungal isolates or human specimens, including cerebrospinal fluid (CSF), synovial fluid, and abscess tissue, from 469 case patients in 19 states. A novel broad-range PCR assay and DNA sequencing were used to evaluate these specimens. Although Aspergillus fumigatus was recovered from the index case, Exserohilum rostratum was the primary pathogen in this outbreak and was also confirmed from unopened MPA vials. Exserohilum rostratum was detected or confirmed in 191 specimens or isolates from 150 case patients, primarily from Michigan (n = 67 patients), Tennessee (n = 26), Virginia (n = 20), and Indiana (n = 16). Positive specimens from Michigan were primarily abscess tissues, while positive specimens from Tennessee, Virginia, and Indiana were primarily CSF. E. rostratum antifungal susceptibility MIC50 and MIC90 values were determined for voriconazole (1 and 2 μg/ml, respectively), itraconazole (0.5 and 1 μg/ml), posaconazole (0.5 and 1 μg/ml), isavuconazole (4 and 4 μg/ml), and amphotericin B (0.25 and 0.5 μg/ml). Thirteen other mold species were identified among case patients, and four other fungal genera were isolated from the implicated MPA vials. The clinical significance of these other fungal species remains under investigation. The laboratory response provided significant support to case confirmation, enabled linkage between clinical isolates and injected vials of MPA, and described significant features of the fungal agents involved in this large multistate outbreak. PMID:23761142
Qureshi, Zaina P.; Norris, LeAnn; Sartor, Oliver; McKoy, June M.; Armstrong, John; Raisch, Dennis W.; Garg, Vishvas; Stafkey-Mailey, Dana; Bennett, Charles Lee
2012-01-01
Purpose: Counterfeit pharmaceuticals pose risks domestically. Because of their cost, cancer pharmaceuticals are vulnerable. We review findings from a domestic counterfeiting episode involving erythropoietin and outline anticounterfeiting recommendations for policy makers, patients, and health care professionals. Materials and Methods: Information was obtained on patients who received counterfeit erythropoietin, its distribution, and criminal investigations into counterfeiting networks. Interview sources included a physician, an attorney, employees of the Florida Department of Health and Human Services and the US Food and Drug Administration's (FDA) Office of Criminal Investigation, manufacturers, and wholesalers. Other sources included the book “Dangerous Doses,” LexisNexis (search terms “counterfeit” and “erythropoietin”) and the FDA database. Results: Counterfeit product consisted of 2,000 U vials with counterfeit labels denoting 40,000 U. The counterfeiters, in collaboration with a Miami pharmacy, purchased 110,000 erythropoietin 2,000 U vials and affixed counterfeit labels to each vial. Products were then sold via the pharmaceutical “gray market” to wholesalers, then pharmacy chains. Investigations by Florida government officials implicated 17 persons, all of whom were found guilty of trafficking in counterfeit pharmaceuticals. Despite the large size of the operation, the FDA received reports of only 12 patients who had received counterfeit erythropoietin and detailed information for only two individuals. A 17-year-old liver transplant recipient and a 61-year-old patient with breast cancer experienced loss of efficacy after receiving counterfeit erythropoietin. Conclusion: Wider use of FDA anticounterfeit initiatives, limiting pharmaceutical suppliers to reputable distributors, and educating providers and patients about signs of counterfeit drugs can improve the safety of cancer pharmaceuticals. PMID:23077434
APPARATUS AND TECHNIC FOR THE ADMINISTRATION OF INTRACAVITARY RADIOACTIVE ISOTOPES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michaud, N.J.; Liegner, L.M.
1961-08-01
The method of administration of radioactive isotopes in the treatment of pleural effusions and ascites associated with cancer will vary according to the therapeutic technic. A procedure with a suitable apparatus that utilizes an economical and sterile disposable package is described. The radioactive isotope, whether colloidal chromic phosphate (P/sup 32/) or colloidal gold (Au/sup 198/), can be obtained in th e exact amount prescribed. The entire apparatus is assembled within a few minutes under sterile conditions. Before the hypodermic needles are inserted into the radioactive isotope vial, the air is removed from the tubing by the flow of saline inmore » each segment. Each section is then clamped. The shielded radioactive isotope is then placed on a table or stand and the rubber seal of the vial is swabbed with alcohol or iodine. The inflow needle is inserted just through the rubber stopper and the outflow needle is inserted to the bottom of the vial. This procedure is carried out without removing the vial from the lead container. (auth)« less
Mitsui, Kazuhisa; David, Frank; Tienpont, Bart; Sandra, Koen; Ochiai, Nobuo; Tamura, Hirotoshi; Sandra, Pat
2015-11-27
Micro-vial pyrolysis (PyroVial) was used to study the production of compounds important for the aroma of heat-treated natural products such as tobacco. Firstly, a mixture of glucose and proline was pyrolyzed as model, as this sugar and amino acid are also abundant in tobacco leaf (Nicotiana tobacum L.). The pyrolysate was analyzed using headspace-GC–MS, liquid injection GC–MS and LC–MS. Next, micro-vial pyrolysis in combination with LC–MS was applied to tobacco leaf extract. Using MS deconvolution, molecular feature extraction and differential analysis it was possible to identify Amadori intermediates of the Maillard reaction in the tobacco leaf extract. The intermediate disappeared as was the case for 1-deoxy-1-prolino-β-d-fructose or the concentration decreased in the pyrolysate compared to the original extract such as for the 1-deoxy-1-[2-(3-pyridyl)-1-pyrrolidinyl]-β-d-fructose isomers indicating that Amadori intermediates are important precursors for aroma compound formation.
Isolation of HIV-1 from experimentally contaminated multidose local anaesthetic vials.
Druce, J D; Locarnini, S A; Birch, C J
1995-05-15
To investigate the hypothesis that HIV can be transmitted via contamination of multidose vials of local anaesthetic solution through reuse of needles and syringes. Laboratory study. (1) By experiments with multidose vials and disposable needles and syringes, we identified a sequence of events in which HIV could contaminate the anaesthetic solution. (2) Three anaesthetic solutions were contaminated with a laboratory strain of HIV and tested by viral culture and p24 enzyme immunoassay one, two and four hours later to see how long the virus remained active. (1) Needles and syringes retained small volumes of fluid after use (mean, 25 microL; in syringe alone, mean 16 microL) which could be transferred to multidose vials of local anaesthetic. (2) 10 mL of anaesthetic solution contaminated with 8 microL of HIV-infected solution (equivalent to 1% infected lymphocytes in vivo) contained active virus one hour later. In some settings, HIV could be isolated four hours after exposure. When inadvertently contaminated with HIV, multidose solutions represent a potential source of transmissible virus.
2012-09-01
basic form of phosphoric acid or sodium phosphate NO2- Nitrite OH- Hydroxide ion ERDC/EL TR-12-14 1 1 Introduction Alkaline hydrolysis has...into amber sample vials and refrigerated until analyzed. TNT analyses were conducted by high performance liquid chromatography (HPLC) with a C-18...The explosives concentrations of the different soils were quantified using a DIONEX HPLC system equipped with a C-18 reverse phase column and a
Shrivastava, Ashutosh; Gupta, Neeraj; Upadhyay, Pramod; Puliyel, Jacob
2012-01-01
Background & objectives: Stabilized live attenuated oral polio vaccine (OPV) is used to immunize children up to the age of five years to prevent poliomyelitis. It is strongly advised that the cold-chain should be maintained until the vaccine is administered. It is assumed, that vaccine vial monitors (VVMs) are reliable at all temperatures. VVMs are tested at 37°C and it is assumed that the labels reach discard point before vaccine potency drops to >0.6 log10. This study was undertaken to see if VVMs were reliable when exposed to high temperatures as can occur in field conditions in India. Methods: Vaccine vials with VVMs were incubated (10 vials for each temperature) in an incubator at different temperatures at 37, 41, 45 and 49.5°C. Time-lapse photographs of the VVMs on vials were taken hourly to look for their discard-point. Results: At 37 and 41°C the VVMs worked well. At 45°C, vaccine potency is known to drop to the discard level within 14 h whereas the VVM discard point was reached at 16 h. At 49.5°C the VVMs reached discard point at 9 h when these should have reached it at 3 h. Conclusion: Absolute reliance cannot be placed on VVM in situation where environmental temperatures are high. Caution is needed when using ‘outside the cold chain’ (OCC) protocols. PMID:22664500
Telepharmacy and bar-code technology in an i.v. chemotherapy admixture area.
O'Neal, Brian C; Worden, John C; Couldry, Rick J
2009-07-01
A program using telepharmacy and bar-code technology to increase the presence of the pharmacist at a critical risk point during chemotherapy preparation is described. Telepharmacy hardware and software were acquired, and an inspection camera was placed in a biological safety cabinet to allow the pharmacy technician to take digital photographs at various stages of the chemotherapy preparation process. Once the pharmacist checks the medication vials' agreement with the work label, the technician takes the product into the biological safety cabinet, where the appropriate patient is selected from the pending work list, a queue of patient orders sent from the pharmacy information system. The technician then scans the bar code on the vial. Assuming the bar code matches, the technician photographs the work label, vials, diluents and fluids to be used, and the syringe (before injecting the contents into the bag) along with the vial. The pharmacist views all images as a part of the final product-checking process. This process allows the pharmacist to verify that the correct quantity of medication was transferred from the primary source to a secondary container without being physically present at the time of transfer. Telepharmacy and bar coding provide a means to improve the accuracy of chemotherapy preparation by decreasing the likelihood of using the incorrect product or quantity of drug. The system facilitates the reading of small product labels and removes the need for a pharmacist to handle contaminated syringes and vials when checking the final product.
Aluminum elution and precipitation in glass vials: effect of pH and buffer species.
Ogawa, Toru; Miyajima, Makoto; Wakiyama, Naoki; Terada, Katsuhide
2015-02-01
Inorganic extractables from glass vials may cause particle formation in the drug solution. In this study, the ability of eluting Al ion from borosilicate glass vials, and tendencies of precipitation containing Al were investigated using various pHs of phosphate, citrate, acetate and histidine buffer. Through heating, all of the buffers showed that Si and Al were eluted from glass vials in ratios almost the same as the composition of borosilicate glass, and the amounts of Al and Si from various buffer solutions at pH 7 were in the following order: citrate > phosphate > acetate > histidine. In addition, during storage after heating, the Al concentration at certain pHs of phosphate and acetate buffer solution decreased, suggesting the formation of particles containing Al. In citrate buffer, Al did not decrease in spite of the high elution amount. Considering that the solubility profile of aluminum oxide and the Al eluting profile of borosilicate glass were different, it is speculated that Al ion may be forced to leach into the buffer solution according to Si elution on the surface of glass vials. When Al ions were added to the buffer solutions, phosphate, acetate and histidine buffer showed a decrease of Al concentration during storage at a neutral range of pHs, indicating the formation of particles containing Al. In conclusion, it is suggested that phosphate buffer solution has higher possibility of forming particles containing Al than other buffer solutions.
Wong, Chin Lin; Lam, Ai-Leen; Smith, Maree T.; Ghassabian, Sussan
2016-01-01
The direct peptide reactivity assay (DPRA) is a validated method for in vitro assessment of the skin sensitization potential of chemicals. In the present work, we describe a peptide reactivity assay using 96-well plate format and systematically identified the optimal assay conditions for accurate and reproducible classification of chemicals with known sensitizing capacity. The aim of the research is to ensure that the analytical component of the peptide reactivity assay is robust, accurate, and reproducible in accordance with criteria that are used for the validation of bioanalytical methods. Analytical performance was evaluated using quality control samples (QCs; heptapeptides at low, medium, and high concentrations) and incubation of control chemicals (chemicals with known sensitization capacity, weak, moderate, strong, extreme, and non-sensitizers) with each of three synthetic heptapeptides, viz Cor1-C420 (Ac-NKKCDLF), cysteine- (Ac-RFAACAA), and lysine- (Ac-RFAAKAA) containing heptapeptides. The optimal incubation temperature for all three heptapeptides was 25°C. Apparent heptapeptide depletion was affected by vial material composition. Incubation of test chemicals with Cor1-C420, showed that peptide depletion was unchanged in polypropylene vials over 3-days storage in an autosampler but this was not the case for borosilicate glass vials. For cysteine-containing heptapeptide, the concentration was not stable by day 3 post-incubation in borosilicate glass vials. Although the lysine-containing heptapeptide concentration was unchanged in both polypropylene and borosilicate glass vials, the apparent extent of lysine-containing heptapeptide depletion by ethyl acrylate, differed between polypropylene (24.7%) and glass (47.3%) vials. Additionally, the peptide-chemical complexes for Cor1-C420-cinnamaldehyde and cysteine-containing heptapeptide-2, 4-dinitrochlorobenzene were partially reversible during 3-days of autosampler storage. These observations further highlight the difficulty in adapting in vitro methods to high-throughput format for screening the skin sensitization potential of large numbers of chemicals whilst ensuring that the data produced are both accurate and reproducible. PMID:27014067
Haidari, Leila A.; Wahl, Brian; Brown, Shawn T.; Privor-Dumm, Lois; Wallman-Stokes, Cecily; Gorham, Katie; Connor, Diana L.; Wateska, Angela R.; Schreiber, Benjamin; Dicko, Hamadou; Jaillard, Philippe; Avella, Melanie; Lee, Bruce Y.
2015-01-01
BACKGROUND While the size and type of a vaccine container (i.e., primary container) can have many implications on the safety and convenience of a vaccination session, another important but potentially overlooked consideration is how the design of the primary container may affect the distribution of the vaccine, its resulting cost, and whether the vial is ultimately opened. METHODS Using our HERMES software platform, we developed a simulation model of the World Health Organization Expanded Program on Immunization supply chain for the Republic of Benin and used the model to explore the effects of different primary containers for various vaccine antigens. RESULTS Replacing vaccines with presentations containing fewer doses per vial reduced vaccine availability (proportion of people arriving for vaccines who are successfully immunized) by as much as 13% (from 73% at baseline) and raised logistics costs by up to $0.06 per dose administered (from $0.25 at baseline) due to increased bottlenecks, while reducing total costs by as much as $0.15 per dose administered (from $2.52 at baseline) due to lower open vial wastage. Primary containers with a greater number of doses per vial each improved vaccine availability by 19% and reduced logistics costs by $0.05 per dose administered, while raising the total costs by up to $0.25 per dose administered due to greater vaccine procurement needs. Changes in supply chain performance were more extreme in departments with greater constraints. Implementing a vial opening threshold reversed the direction of many of these effects. CONCLUSIONS Our results show that one size may not fit all when choosing a primary vaccine container. Rather, the choice depends on characteristics of the vaccine, the vaccine supply chain, immunization session size, and goals of decision-makers. In fact, the optimal vial size may vary among locations within a country. Simulation modeling can help identify tailored approaches to improve availability and efficiency. PMID:25889160
Sasaki, Hitoshi; Kikuchi, Jun; Maeda, Terutoshi; Kuboniwa, Hitoshi
2010-01-01
The purpose of this study was to evaluate the effect of moisture permeability of different elastomer formulation stoppers, which had different moisture absorption abilities, on the increase of moisture content inside lyophilized vials during long-term storage under humid conditions. Two different elastomer formulation stoppers (high-moisture and low-moisture uptake stoppers) were compared. The increased amount of moisture content inside lyophilized vials fitted with high-moisture stoppers was higher than those fitted with low-moisture stoppers during the early stage of storage. However, this trend was reversed during the later stage of storage. Our data show that the moisture increase inside the lyophilized vials at the early stage was caused by moisture transfer from the stoppers, whereas the later moisture increase was caused by external moisture permeation through the stoppers. Results indicate that the difference in the moisture uptake profile inside the lyophilized vials at each period of storage was caused by the moisture absorption ability and moisture permeation ability of the two elastomer formulation stoppers. In terms of long-term storage stability under humid conditions, our data indicate that external moisture permeating through the stopper into the lyophilized vial during the late stage was the more important factor. In addition, the increase in moisture content at the early stage was controlled by stopper drying time. Furthermore, stopper drying time did not have an effect on moisture permeation at the late stage. Moisture permeation during the storage period appears to be dependent on the different elastomer formulations of the stoppers. The moisture permeation of different elastomer stoppers was an important factor in terms of the increased moisture content inside the lyophilized vials during the late stage of long-term storage under humid conditions. For lyophilized products stored at room temperature, the moisture permeation ability of the stopper is one of the most important factors for long-term storage stability.
Lucidi, P; Porcellati, F; Marinelli Andreoli, A; Candeloro, P; Cioli, P; Bolli, G B; Fanelli, C G
2017-06-06
This study measured the insulin concentration (Ins [C] ) of NPH insulin in vials and cartridges from different companies after either resuspension (R+) or not (R-; in the clear/cloudy phases of unsuspended NPH). Measurements included Ins [C] in NPH(R+) and in the clear/cloudy phases of NPH(R-), and the time needed to resuspend NPH and time for NPH(R+) to separate again into clear/cloudy parts. In vials of NPH(R+) (assumed to be 100%), Ins [C] in the clear phase of NPH(R-) was<1%, but 230±41% and 234±54% in the cloudy phases of Novo Nordisk and Eli Lilly NPH, respectively. Likewise, in pen cartridges, Ins [C] in the clear phase of NPH(R-) was<1%, but 182±33%, 204±22% and 229±62% in the cloudy phases of Novo, Lilly and Sanofi NPH. Time needed to resuspend NPH (spent in tipping) in vials was brief with both Novo (5±1s) and Lilly NPH (6±1s), but longer with all pen cartridges (50±8s, 40±6s and 30±4s from Novo, Lilly and Sanofi, respectively; P=0.022). Time required for 50% separation into cloudy and clear parts of NPH was longer with Novo (60±7min) vs. Lilly (18±3min) in vials (P=0.021), and affected by temperature, but not by the different diameter sizes of the vials. With pen cartridges, separation into clear and cloudy parts was significantly faster than in vials (P<0.01). Ins [C] in NPH preparations varies depending on their resuspension or not. Thus, subcutaneous injection of the same number of units of NPH in patients with diabetes may deliver different amounts of insulin depending on its prior NPH resuspension. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Haidari, Leila A; Wahl, Brian; Brown, Shawn T; Privor-Dumm, Lois; Wallman-Stokes, Cecily; Gorham, Katie; Connor, Diana L; Wateska, Angela R; Schreiber, Benjamin; Dicko, Hamadou; Jaillard, Philippe; Avella, Melanie; Lee, Bruce Y
2015-06-22
While the size and type of a vaccine container (i.e., primary container) can have many implications on the safety and convenience of a vaccination session, another important but potentially overlooked consideration is how the design of the primary container may affect the distribution of the vaccine, its resulting cost, and whether the vial is ultimately opened. Using our HERMES software platform, we developed a simulation model of the World Health Organization Expanded Program on Immunization supply chain for the Republic of Benin and used the model to explore the effects of different primary containers for various vaccine antigens. Replacing vaccines with presentations containing fewer doses per vial reduced vaccine availability (proportion of people arriving for vaccines who are successfully immunized) by as much as 13% (from 73% at baseline) and raised logistics costs by up to $0.06 per dose administered (from $0.25 at baseline) due to increased bottlenecks, while reducing total costs by as much as $0.15 per dose administered (from $2.52 at baseline) due to lower open vial wastage. Primary containers with a greater number of doses per vial each improved vaccine availability by 19% and reduced logistics costs by $0.05 per dose administered, while reducing the total costs by up to $0.25 per dose administered. Changes in supply chain performance were more extreme in departments with greater constraints. Implementing a vial opening threshold reversed the direction of many of these effects. Our results show that one size may not fit all when choosing a primary vaccine container. Rather, the choice depends on characteristics of the vaccine, the vaccine supply chain, immunization session size, and goals of decision makers. In fact, the optimal vial size may vary among locations within a country. Simulation modeling can help identify tailored approaches to improve availability and efficiency. Copyright © 2015 Elsevier Ltd. All rights reserved.
Quantum Dotting the "i" of Inquiry: A Guided Inquiry Approach to Teaching Nanotechnology
ERIC Educational Resources Information Center
Laubach, Timothy A.; Elizondo, Lee A.; McCann, Patrick J.; Gilani, Shahryar
2010-01-01
When illuminating four "mystery" vials of nanoparticle solution with a 405-nm light emitting diode (LED), four distinct colors related to the peak wavelength of fluorescent emission can be observed. This phenomenon perplexes high school physics students and leads to the subsequent exploratory question, "Why are the four vials emitting a different…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-15
...] Determination that ROCEPHIN (Ceftriaxone Sodium) Injection, 250 Milligrams, 500 Milligrams, 1 Gram, 2 Grams, and 10 Grams Base/Vial, Approved Under New Drug Application 050585, Were Not Withdrawn From Sale for... milligrams (mg), 500mg, 1 gram (g), 2g, and 10g base/vial, approved under new drug application (NDA) 050585...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-22
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-779] Certain Flip-Top Vials and Products Using the... AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on May 17, 2011, under section 337 of the...
Development of a correction factor for Xe-133 vials for use with a dose calibrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gels, G.L.; Piltingsrud, H.V.
1982-04-01
Manufacturers of dose calibrators who give calibration settings for various radionuclies sometimes do not specify the type of radionuclide container the calibration is for. The container, moreover, may not be of the same type as those a user might purchase. When these factors are not considered, the activity administered to the patient may be significantly different from that intended. An experiment is described in which calibration factors are determined for measurement of Xe-133 activity in vials in a dose calibrator. This was accomplished by transferring the Xe-133 from the commercial vials to standard NBS calibration ampules. Based on ten suchmore » transfers, the resulting correction factor for the dose calibrator was 1.22.« less
Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan
2018-04-01
We report on a headspace gas chromatographic method for determining the content of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution. It was based on quantitatively converting 3-chloro-1,2-propanediol to formaldehyde by periodate oxidation in a closed headspace sample vial at a room temperature for 10 min, and then to methanol by borohydride reduction at 90°C for 40 min followed by the headspace gas chromatographic measurement. The results showed that the present method has an excellent measurement precision (relative standard deviation < 2.60%) and accuracy (recoveries from 96.4-102%) in 3-chloro-1,2-propanediol analysis. The limit of quantitation was 0.031 mg/mL. It is simple and suitable for determining the 3-chloro-1,2-propanediol content in polyamideamine epichlorohydrin resin solution. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Trace elements in a commercial freeze-dried human urine reference material.
Veillon, C; Patterson, K Y
1996-07-01
A large batch of freeze-dried human urine reference material, Seronorm Trace Elements Urine, Lot 101021, was prepared commercially (Nycomed Pharma AS, Oslo, Norway) for quality control purposes in trace element analysis. Analytes are being determined by a voluntary, international co-operative effort so that the material will be available to the scientific community at modest cost. The material is in stoppered glass vials and is to be reconstituted with 5.00 ml of water prior to use. We have evaluated the trace element content for several elements, including chromium and zinc, elements for which we have two independent methods available for the determinations, namely isotope dilution mass spectrometry (IDMS) and atomic absorption spectrometry (AAS). We also report on other trace elements measured by IDMS alone, such as Se, for which we have enriched stable isotopes available. Results for chromium indicate a mean +/- standard deviation (n = 10) of 1.2 +/- 0.3 (by IDMS) and 1.4 +/- 0.3 (by AAS) ng Cr per ml of reconstituted urine, indicating possible inhomogeneity and/or contamination (21-25% relative standard deviation, RSD). Approximately half of the observed chromium originates from the sample container. The values observed for zinc were 590 +/- 90 ng ml-1 (15% RSD) for freshly reconstituted material, 760 +/- 60 ng ml-1 (8% RSD) for material reconstituted 4 d earlier, and 940 +/- 60 ng ml-1 (6% RSD) 2 months after reconstitution. Selenium values by IDMS were very reproducible, with a mean concentration of 16 +/- 0.15 ng g-1 (0.9% RSD), suggesting little or no contamination and a high degree of sample homogeneity for this element. The source of potential contaminants has been evaluated by multielement determinations of leachates of the vials and stoppers. Elements noted in significant amounts include B, Ba, Sr, Mo, Cu and Zn, with most of the zinc coming from the rubber stopper.
Taylor, T B; Patterson, C; Hale, Y; Safranek, W W
1997-01-01
A PCR-restriction fragment length polymorphism (PCR-RFLP) procedure capable of rapidly identifying 28 species of clinically encountered mycobacteria was evaluated for use in the routine identification of acid-fast isolates growing in BACTEC 12B and 13A liquid media. PCR-RFLP identified 100 of 103 acid-fast isolates recovered from 610 patient specimens submitted for culture during the study. The three isolates unidentifiable by PCR-RFLP produced restriction patterns not included in the PCR-RFLP algorithm and could therefore not be assigned to a species. These isolates were characterized by their morphologic and biochemical characteristics. Two of the isolates were identified as M. terrae complex and M. gordonae. The third isolate could not be definitively identified and could only be characterized as a Mycobacterium sp. most closely resembling M. chelonae. PCR-RFLP identifications agreed with the conventional identifications for 96 of the 100 isolates identified by PCR-RFLP. Subsequent identification of the four discordant isolates by gas chromatography analysis supported the PCR-RFLP identification of each isolate. Amplification products were also obtained from isolates of Streptococcus albus and Rhodococcus equi recovered from patient specimens; however, the restriction patterns of these nonmycobacterial species did not resemble the patterns of any mycobacterial species included in the PCR-RFLP algorithm. PCR-RFLP seems to be a reliable procedure for the routine identification of mycobacteria and has the potential for providing identifications of mycobacterial isolates which are more accurate than conventional identification techniques based on morphologic and biochemical characteristics. PMID:8968884
Motwani, Girish; Mehta, Rujuta; Aroojis, Alaric; Vaidya, Sandeep
2017-01-01
Early treatment of septic arthritis is essential before irreversible damage to the articular cartilage occurs. Clinicians often start empirical antibiotic therapy for symptomatic relief while awaiting a definitive culture report. In present day parlance with variations in different centres in the private and public sector and rampant antibiotic abuse, a lot of resistance is being seen in the flora and their sensitivity patterns. Hence it is imperative to document and analyze these changing trends. The authors conducted a retrospective analysis of prospectively gathered data of 60 patients under 14 years of age. Joint arthrotomy was performed as a standard therapeutic protocol and the drained pus or synovial fluid was sent for gram stain and culture by 2 different methods: conventional agar plate method and BACTEC Peds Plus/F bottle method. Antibiotic susceptibility tests were done by the disc diffusion method of Clinical Laboratory Standards Institute (CLSI). The commonest presenting age group was below 1 year (80% patients) including 24 neonates. There were 19 hospital and 41 community acquired cases of septic arthritis. The hip (56%) was the commonest affected joint followed by knee (28%), shoulder joint (11%) and elbow (5%). Microorganism was isolated in 53% isolates of joint fluid only (36 culture positive patients). Conventional agar methods of culture showed positive report in only 42% patients (15/36 patients) while with the BACTEC method the yield was 71%. In the Community acquired septic arthritis, methicillin sensitive Staphylococcus aureus was isolated as commonest microbe while resistant variety of gram negative bacilli including E. coli and Klebsiella were found as predominant organism causing hospital acquired nosocomial infection of joints. The results strikingly differ in terms of response to treatment as most patients (11/19 patients) showed significant resistance to the most commonly practiced empirical antibiotic regimen of ampicillin-cloxacillin group in routine practice. When cefazolin was used as empirical antibiotic, it has shown good response and better sensitivity in 82% patients (27/33 patients). S. aureus is still the most common organism in septic arthritis. The BACTEC system was found to improve the yield of clinically significant isolates. Though a significant resistance to common antibiotic regimen is noticed, the strain is susceptible to cephalosporin group of antibiotics. We recommend the use of cephalosporine antibiotics as an empirical therapy till culture and sensitivity report are available.
Assessment of Digoxin-Specific Fab Fragment Dosages in Digoxin Poisoning.
Nordt, Sean Patrick; Clark, Richard F; Machado, Carol; Cantrell, F Lee
2016-01-01
Digoxin poisoning still remains a common cause of morbidity and mortality. Fortunately, digoxin-specific Fab fragments are commercially available as an antidote. However, these Fab fragments are several thousand dollars per vial. There is a standardized formula to calculate appropriate Fab fragment dosage based on the serum digoxin concentration. This can greatly reduce the amount of Fab fragment administered. There is also an empiric dosing guideline recommending 6-10 vials be given; however, this may result in higher amounts of Fab fragments being administered than required. We performed this study to assess the amounts of digoxin-specific Fab fragments administered in the treatment of digoxin poisonings recorded in a poison control system database from January 1, 2000, to December 31, 2009, in which digoxin serum concentrations were available. This was a retrospective study of 278 patients, 107 with acute poisonings (group A) and 171 following chronic poisoning (group B). In group A, the calculated Fab dose was higher than the calculated dose based on available concentrations in 39 (36%) of group A and 15 (9%) of group B patients. The average wholesale price cost of the excessive dosages ranged from $4818 to as high as $50,589 per patient. Our data suggests that clinician education on digoxin poisoning and the use of the standardized formula to calculate the Fab dose may decrease over utilization and decrease costs associated with the administration of digoxin-specific Fab fragments in the treatment of digoxin poisonings.
Is rhodopsin isomerization correlated to astronauts' phosphene perceptions in space?
NASA Astrophysics Data System (ADS)
Narici, L.; Altea-Biophys Team
Anomalous Phosphene Perception APP phoenomenon may just be a first example of how microgravity and particle radiation may modify the normal behaviour of the Central Nervous System CNS and also is an evidence that space environment may indeed influence the correct functioning of the visual system The ALTEA program is going to provide i an assesment of the CNS functional hazard due to microgravity and particle radiation during long space human permanence ii a definition for the needed shielding optimized for reducing these risks and iii a survey of ISS radiation environment aimed at the validation of spacecrafts computer models As known Rhodopsin is at the start of the photo-transduction cascade and its involvement in the phosphene perception would suggest a possible physiological pathway The bleaching of few molecules in the retina is sufficient to start the process of vision A very preliminary measurements on rhodopsin irradiation has been conducted in April 2003 Irradiation of 17 vials containing a solution of suine rhodopsine has been performed with 12 C ions at 200 MeV n - total dose has been varied from 10 9 to 10 13 ions over each vial New and more complete data from most recent measurements are now available Preparation and purification of bovine rhodopsin and regenerations of bleached molecules was carried out using reproducible procedures The samples was irradiated with controlled 12 C ion beams and with different amount of light radiation in order 1 to understand if the molecules have been
Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan; Chen, Chun-Xia
2017-12-29
This paper reports on an ionic-liquid assisted headspace gas chromatographic (HS-GC) for the determination of the content of alkyl ketene dimer (AKD) in its latex samples, in which the GC system was equipped with a thermal conductivity detector (TCD). The method was based on the AKD hydrolysis conducted in 1-butyl-3-methylimidazolium chloride (ionic-liquid) added medium at 100°C for 10min in a closed headspace sample vial, and the measured CO 2 (the resulting product of the hydrolysis) by HS-GC. The results showed that the present method has a good measurement precision (RSD <2.3%) and accuracy (recoveries from 96 - 105%), and the limit of quantitation (LOQ) is 0.9%. The present method is very suitable to be used for the routine check of AKD content in its latex sample in mill applications. The study also showed that the content of AKD in the tested commercial latex samples were in the range of 3.5-12%. Copyright © 2017 Elsevier B.V. All rights reserved.
Tang, Xiaolin Charlie; Nail, Steven L; Pikal, Michael J
2006-01-01
The purpose of this work was to study the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to determine product dry-layer resistance to vapor flow. Product temperature and dry-layer resistance were obtained using MTM software installed on a laboratory freeze-dryer. The MTM resistance values were compared with the resistance values obtained using the "vial method." The product dry-layer resistances obtained by MTM, assuming fixed temperature difference (DeltaT; 2 degrees C), were lower than the actual values, especially when the product temperatures and sublimation rates were low, but with DeltaT determined from the pressure rise data, more accurate results were obtained. MTM resistance values were generally lower than the values obtained with the vial method, particularly whenever freeze-drying was conducted under conditions that produced large variations in product temperature (ie, low shelf temperature, low chamber pressure, and without thermal shields). In an experiment designed to magnify temperature heterogeneity, MTM resistance values were much lower than the simple average of the product resistances. However, in experiments where product temperatures were homogenous, good agreement between MTM and "vial-method" resistances was obtained. The reason for the low MTM resistance problem is the fast vapor pressure rise from a few "warm" edge vials or vials with low resistance. With proper use of thermal shields, and the evaluation of DeltaT from the data, MTM resistance data are accurate. Thus, the MTM method for determining dry-layer resistance is a useful tool for freeze-drying process analytical technology.
Peretz, A; Isakovich, N; Pastukh, N; Koifman, A; Glyatman, T; Brodsky, D
2015-08-01
Blood is one of the most important specimens sent to a microbiology laboratory for culture. Most blood cultures are incubated for 5-7 days, except in cases where there is a suspicion of infection caused by microorganisms that proliferate slowly, or infections expressed by a small number of bacteria in the bloodstream. Therefore, at the end of incubation, misidentification of positive cultures and false-negative results are a real possibility. The aim of this work was to perform a confirmation by Gram staining of the lack of any microorganisms in blood cultures that were identified as negative by the BACTEC™ FX system at the end of incubation. All bottles defined as negative by the BACTEC FX system were Gram-stained using an automatic device and inoculated on solid growth media. In our work, 15 cultures that were defined as negative by the BACTEC FX system at the end of the incubation were found to contain microorganisms when Gram-stained. The main characteristic of most bacteria and fungi growing in the culture bottles that were defined as negative was slow growth. This finding raises a problematic issue concerning the need to perform Gram staining of all blood cultures, which could overload the routine laboratory work, especially laboratories serving large medical centers and receiving a large number of blood cultures.
Bactericidal activity of OPC-67683 against drug-tolerant Mycobacterium tuberculosis.
Saliu, Oluwabunmi Y; Crismale, Catina; Schwander, Stephan K; Wallis, Robert S
2007-11-01
There is an urgent need for drugs that hasten sterilization in tuberculosis; however, we presently lack indicators of this activity to guide early drug development. We previously described a novel in vitro assay to study mycobacterial phenotypic drug tolerance, in which sterilizing activity could be assessed. OPC-67,683 is a novel imidazooxazole that accelerates sterilization in the mouse tuberculosis model. The present study was conducted to determine the activity of OPC-67,683 in the in vitro tolerance model using drug-tolerant clinical Mycobacterium tuberculosis strains. Tolerance was assessed in Bactec radiometric culture as: (i) delayed decline in growth index during 14 days of drug exposure; (ii) shorter time to positivity of subcultures following drug exposure. Four isolates were selected from among 16 surveyed, based on delayed killing by isoniazid and OPC-67,683. Unlike isoniazid and rifampicin, whose rates of killing were concentration-independent, OPC-67,683 showed concentration-dependent effects that, at the highest dose levels tested (1.0 microg/mL), were superior to isoniazid and equal to rifampicin. The sterilizing activity of OPC-67683 against drug-tolerant M. tuberculosis in the Bactec model is consistent with its activity in mice. Further studies are warranted to examine the effects of OPC-67683 on mycobacterial persistence in tuberculous patients and to determine the biological basis of tolerance in the model.
Yamamoto, Kei; Hayakawa, Kayoko; Nagashima, Maki; Shimada, Kayo; Kutsuna, Satoshi; Takeshita, Nozomi; Kato, Yasuyuki; Kanagawa, Shuzo; Yamada, Koji; Mezaki, Kazuhisa; Kirikae, Teruo; Ohmagari, Norio
2017-11-28
Campylobacter spp. and Helicobacter spp. are rare but important causes of bacteremia in humans. Distinguishing these bacteria is complicated because of their similar phenotypic profiles. We conducted clinical and microbiological investigations of Campylobacter spp. or Helicobacter spp. bacteremia. Patients diagnosed with bacteremia from 2008 to 2014 were included. The clinical and microbiological characteristics of Campylobacter spp. and Helicobacter spp. bacteremia were compared. The BACTEC system was used in blood cultures. A receiver operating characteristic curve was plotted based on the time to blood culture positivity. Sixteen cases of Helicobacter spp. bacteremia (patient age: 61 ± 18 years) and 14 cases of Campylobacter spp. bacteremia (patient age: 49 ± 21 years) were identified. Median time to blood culture positivity was longer for the Helicobacter spp. cases than the Campylobacter spp. cases (91.4 h vs 55.3 h, p < 0.01). A time to blood culture positivity > 75 h predicted Helicobacter spp. bacteremia with a sensitivity of 0.88 and a specificity of 0.93 (area under the receiver operating characteristic curve of 0.90). In conclusion, a time to blood culture positivity was useful in distinguishing Helicobacter spp. bacteremia from Campylobacter spp. bacteremia.
Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M
2016-05-01
The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.
Campagna, Raphael; Pessis, Eric; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc
2013-02-01
To evaluate the occurrence of coring after needle insertion through the rubber stopper of prednisolone acetate vials. Two-hundred vials of prednisolone acetate were randomly distributed to two radiologists. Prednisolone acetate was drawn up through the rubber bung of the vials with an 18-gauge cutting bevelled needle and aspirated with a 5-ml syringe. The presence of coring was noted visually. We systematically put each core in a syringe refilled with 3 ml prednisolone acetate, and injected the medication through a 20-gauge spine needle. Computed tomography was performed to measure the size of each coring. Coring occurred in 21 out of 200 samples (10.5 %), and was visually detected in the syringe filled up with prednisolone in 11 of the 21 cases. Ten more occult cores were detected only after the syringes and needles were taken apart and rinsed. The core size ranged from 0.6 to 1.1 mm, and 1 of the 21 (4.7 %) cores was ejected through the 20-gauge needle. Coring can occur after the insertion of a needle through the rubber stopper of a vial of prednisolone acetate, and the resultant core can then be aspirated into the syringe.
Hinoue, Mitsuo; Hori, Hajime
2017-01-01
For a new desorption method development for working environment measurement, desorption efficiency of organic solvent vapors from an activated carbon was examined using desorption solutions that consisted of anionic and nonionic surfactants. Ten μl of an aqueous solution of isopropyl alcohol or methyl ethyl ketone diluted with distilled water was spiked into a 10 ml vial with a coconut-shell-activated carbon (100 mg). The vial was left for 24 h, and 5 ml a desorption solution was added. Afterwards, the vial was put into an incubator at 60°C and left for 24 h, then the desorption efficiency was determined by analyzing the headspace gas in the vial with a gas chromatograph equipped with flame ionization detector. By adding one or four kinds of nonionic surfactants to the aqueous solution containing two kinds of anionic surfactants, the effect adding nonionic surfactant to the desorption efficiency was investigated, but improvement of desorption efficiency was not observed. On the other hand, desorption efficiency varied depending on the production lot of the coconut-shell-activated carbon tube used as the adsorbent.
NASA Astrophysics Data System (ADS)
Cai, Tingdong; Wang, Guishi; Cao, Zhensong; Zhang, Weijun; Gao, Xiaoming
2014-07-01
The concentration of H2O and the pressure in the headspace of vials are simultaneously measured by a tunable diode laser sensor based on absorption spectroscopy techniques. The 7168.437 cm-1 spectral line of H2O is chosen as the sensing transition for its strong absorption strength and being reasonably far away from its neighboring molecular transitions. In order to prevent interference absorption by ambient water vapor in the room air, a difference between the measured signal and the referenced signal is used to calculate the pressure and H2O concentration in the headspace of vials, eliminating the need for inert gas purges and calibration with known gas. The validation of the sensor is conducted in a static vial, yielding an accuracy of 1.23% for pressure and 3.81% for H2O concentration. The sensitivity of the sensor is estimated to be about 2.5 Torr for pressure and 400 ppm for H2O concentration over a 3 cm absorption path length respectively. Accurate measurements for commercial freeze-dried products demonstrate the in-line applications of the sensor for the pharmaceutical industry.
Cai, Tingdong; Gao, Guangzhen; Liu, Ying
2013-11-10
Tunable diode laser absorption measurements of pressure and H2O concentration in the headspace of vials using a distributed-feedback (DFB) diode laser near 1.4 μm are reported. A H2O line located near 7161.41 cm(-1) is selected based on its strong absorption strength and isolation from interference of neighboring transitions. Direct absorption spectra of H2O are obtained for the measurement path as well as the reference path by scanning the laser wavelength. The pressure and H2O vapor concentration in the headspace of a vial are inferred from a differential absorption signal, which is the difference between the measured and the referenced absorbance spectra. This sensor is calibration-free and no purge gas is needed. The demonstrated capability would enable measurements of pressure and H2O concentration in the headspace of vials within 2.21% and 2.86%, respectively. A precision of 1.02 Torr and 390 ppm is found for the pressure and H2O concentration, respectively. A set of measurements for commercial freeze-dried products are also performed to illustrate the usefulness of this sensor.
Halm, Ariane; Yalcouyé, Idrissa; Kamissoko, Mady; Keïta, Tenemakan; Modjirom, Ndoutabé; Zipursky, Simona; Kartoglu, Umit; Ronveaux, Olivier
2010-04-26
We conducted the first systematic documentation of using oral polio vaccine (OPV) out of the cold chain during national immunization day (NID) campaigns in Mali. Using a crossover intervention design, vaccinators compared the transport of OPV in vaccine carriers with or without ice packs. Vaccine integrity was assured through monitoring vaccine vial monitor (VVM) status. Despite ambient temperatures up to 40 degrees C, none of the VVMs on any of the vials used (n=956) reached their discard point. Over 90% of vaccinators and supervisors preferred conducting NIDs without ice packs. In addition, using OPV out of the cold chain reduced vaccine wastage resulting from melting ice packs causing labels to detach from the vial. Copyright 2010 Elsevier Ltd. All rights reserved.
Humalog(®) KwikPen™: an insulin-injecting pen designed for ease of use.
Schwartz, Sherwyn L; Ignaut, Debra A; Bodie, Jennifer N
2010-11-01
Insulin pens offer significant benefits over vial and syringe injections for patients with diabetes who require insulin therapy. Insulin pens are more discreet, easier for patients to hold and inject, and provide better dosing accuracy than vial and syringe injections. The Humalog(®) KwikPen™ (prefilled insulin lispro [Humalog] pen, Eli Lilly and Company, Indianapolis, IN, USA) is a prefilled insulin pen highly rated by patients for ease of use in injections, and has been preferred by patients to both a comparable insulin pen and to vial and syringe injections in comparator studies. Together with an engineering study demonstrating smoother injections and reduced dosing error versus a comparator pen, recent evidence demonstrates the Humalog KwikPen device is an accurate, easy-to-use, patient-preferred insulin pen.
Mathaes, Roman; Mahler, Hanns-Christian; Vorgrimler, Lothar; Steinberg, Henrik; Dreher, Sascha; Roggo, Yves; Nieto, Alejandra; Brown, Helen; Roehl, Holger; Adler, Michael; Luemkemann, Joerg; Huwyler, Joerg; Lam, Philippe; Stauch, Oliver; Mohl, Silke; Streubel, Alexander
2016-01-01
The majority of parenteral drug products are manufactured in glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. Different critical capping process parameters can affect rubber stopper defects, rubber stopper compression, container closure integrity, and also crimp cap quality. A sufficiently high force to remove the flip-off button prior to usage is required to ensure quality of the drug product unit by the flip-off button during storage, transportation, and until opening and use. Therefore, the final product is 100% visually inspected for lose or defective crimp caps, which is subjective as well as time- and labor-intensive. In this study, we sealed several container closure system configurations with different capping equipment settings (with corresponding residual seal force values) to investigate the torque moment required to turn the crimp cap. A correlation between torque moment and residual seal force has been established. The torque moment was found to be influenced by several parameters, including diameter of the vial head, type of rubber stopper (serum or lyophilized) and type of crimp cap (West(®) or Datwyler(®)). In addition, we measured the force required to remove the flip-off button of a sealed container closure system. The capping process had no influence on measured forces; however, it was possible to detect partially crimped vials. In conclusion, a controlled capping process with a defined target residual seal force range leads to a tight crimp cap on a sealed container closure system and can ensure product quality. The majority of parenteral drug products are manufactured in a glass vials with an elastomeric rubber stopper and a crimp cap. The vial sealing process is a critical process step during fill-and-finish operations, as it defines the seal quality of the final product. An adequate force to remove the flip-off button prior to usage is required to ensure product quality during storage and transportation until use. In addition, the complete crimp cap needs to be fixed in a tight position on the vial. In this study, we investigated the torque moment required to turn the crimp cap and the force required to remove the flip-off button of container closure system sealed with different capping equipment process parameters (having different residual seal force values). © PDA, Inc. 2016.
Residual volume in vials of antibiotics used in pediatrics.
Chaves, Caroline Magna Pessoa; Bezerra, Carolina Martins; Lima, Francisca Elisângela Teixeira; Cardoso, Maria Vera Lúcia Moreira Leitão; Fonseca, Said Gonçalves da Cruz; Silva, Viviane Martins da
2017-06-12
Quantifying residual volume contained in vials of antibiotics used in pediatrics. This is an experiment involving samples from vials of antibiotics used in a pediatric hospital. Residual volume was identified by calculating the difference in weight measurement before and after the vials were washed. Evaluation of the residual volume difference in the vials was determined by the Wilcoxon non-parametric test for a sample and established at a significance level of 5%. 105 samples of antibiotics were selected. The correct use of the antibiotics oxacillin (88.57%) and ceftriaxone (94.28%) predominated with low residual values. The same did not occur for procaine benzylpenicillin + potassium benzylpenicillin, since a greater residual volume was discarded in 74.28% of the vials. We highlight the need for improvements in managing antibiotics in the institution under study, so that the excess volume of the antibiotics in the vials is used within the acceptable stable time. It is also necessary that the disposal of the residual volume be adequately disposed, since it presents a risk to public health and the environment. Quantificar o volume residual contido em frascos-ampola de antibióticos utilizados na pediatria. Trata-se de um experimento com amostras de frascos-ampola de antibióticos utilizados em hospital pediátrico. O volume residual foi identificado calculando-se a diferença da aferição do peso antes e após a lavagem do frasco-ampola. A avaliação da diferença dos volumes residuais nos frascos-ampola foi determinada pelo teste não paramétrico de Wilcoxon para uma amostra e estabelecido o nível de significância de 5%. Foram selecionadas 105 amostras de antibióticos. Predominou o correto aproveitamento dos antibióticos oxacilina (88,57%) e ceftriaxona (94,28%), com baixos valores residuais. O mesmo não ocorreu com a benzilpenicilina procaína + potássica, pois em 74,28% dos frascos houve descarte de volume residual superior. Destaca-se a necessidade de melhorias na gestão dos antibióticos na instituição em estudo, para que o volume excedente do antibiótico em frasco-ampola seja aproveitado até o tempo de estabilidade permitido, assim como é necessário que haja a adequação da forma de descarte do volume residual, que apresenta risco à saúde pública e ao meio ambiente.
2007-01-01
sulfide, and calcium silicide . Oxidizing agents include potassium chlorate and barium nitrate. 1-4 ERDC TR-07-1 a. Propellant grain shapes. b...evaporated to dryness under a gentle stream of forced air. The dried extracts were combined with 5 mL 5N sodium hydroxide, and the vials were placed in a...phase was 0.5M carbonate:0.5M bicarbonate and the flow rate was 1.8 mL/min. Injection volume was 50 µL. Potassium nitrate and sodium nitrite were
Detection of a typhus group Rickettsia in Amblyomma ticks in the state of Nuevo Leon, Mexico.
Medina-Sanchez, Aaron; Bouyer, Donald H; Alcantara-Rodriguez, Virginia; Mafra, Claudio; Zavala-Castro, Jorge; Whitworth, Ted; Popov, Vsevolod L; Fernandez-Salas, Ildefonso; Walker, David H
2005-12-01
The state of Nuevo Leon, Mexico has had outbreaks of typhus group rickettsiosis, most recently recognized in 1997. Evaluation of the sera of 345 patients with a dengue-like illness revealed that 25.5% had antibodies reactive with typhus group rickettsiae and 16% had antibodies to Rickettsia parkeri. Rickettsiae were detected by PCR and shell-vial isolations in the field-collected Amblyomma ticks. Molecular characterization by DNA sequence analysis of the gltA, ompB, and 17-kDa gene identified the organisms to be R. prowazekii.
USDA-ARS?s Scientific Manuscript database
A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts. The method was appli...
False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.
Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W
2011-02-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.
Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei
2012-01-01
Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it was verified that the method showed consistent results, and was able to determine the acceptance limit using 3σ for syringes and 6σ for vials.
Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R
1997-01-01
Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.
Pseudoepidemic of Nocardia asteroides associated with a mycobacterial culture system.
Patterson, J E; Chapin-Robertson, K; Waycott, S; Farrel, P; McGeer, A; McNeil, M M; Edberg, S C
1992-01-01
Nocardia isolations increased from 0.7 to 11.7/1,000 acid-fast bacillus and mycological cultures (P less than 0.000001). Only three isolations from one patient represented infection. Pseudoepidemic strain identity was confirmed by DNA fingerprinting; the isolate causing infection was distinct. The end of the pseudoepidemic was associated with changing the needle sterilizer and prolonging needle sterilization time on the BACTEC 460 machine. To our knowledge, this is the first reported Nocardia asteroides pseudoepidemic. Images PMID:1583150
Xie, Lin; Zhou, Steve; Wei, Wenhui; Gill, Jasvinder; Pan, Chunshen; Baser, Onur
2013-03-01
The study was designed to evaluate real-world data on clinical and economic outcome differences between patients with type 2 diabetes mellitus (T2DM) who use insulin glargine with vial-and-syringe delivery and those who switch to pen administration. This retrospective study analyzed medical and pharmacy claims information from the national managed-care IMPACT(®) database (Ingenix Inc., Salt Lake City, UT). Adults with T2DM treated with insulin glargine were evaluated. Clinical and economic outcomes over 1 year were compared between individuals who had converted from administering glargine via vial-and-syringe to the SoloSTAR(®) (sanofi-aventis U.S., Bridgewater, NJ) pen (Switchers) and patients who continued to use vial-and-syringe administration (Continuers). Patients from each cohort were matched using propensity score matching for a comparison sample. In total, 3,893 eligible patients were identified (665 Switchers and 3,228 Continuers), with a matched cohort with 603 patients in each group. Baseline characteristics were similar between groups. One-year treatment persistence was significantly higher with Switchers versus Continuers (65.3% vs. 49.8%; P<0.0001). Medication possession ratio was also significantly higher among Switchers (0.79 vs. 0.76; P=0.0173). Insulin use and glycemic control were similar between groups. Healthcare utilization and total costs were also similar between groups. Higher prescription costs among Switchers were offset by lower overall and diabetes-related outpatient and inpatient costs. Switching from insulin glargine vial-and-syringe administration to pen delivery resulted in improved treatment adherence and persistence, with comparable clinical and economic outcomes.
Seagraves, Michael P; McPherson, Robert M
2003-06-01
The red imported fire ant, Solenopsis invicta Buren, is an abundant predator in cropping systems throughout its range. It has been documented to be an important predator of numerous crop pests, as well as being an agricultural pest itself. Information on the impact of insecticides on natural enemies such as fire ants is necessary for the integration of biological and chemical control tactics in an effective pest management program. Therefore, a residual vial bioassay was developed to determine the concentration-mortality responses of S. invicta workers to four commonly used insecticides: acephate, chlorpyrifos, methomyl and lambda-cyhalothrin. Fire ant workers showed a mortality response to serial dilutions to all four chemicals. Methomyl (LC50 0.04 microg/vial, fiducial limits 0.03-0.06) was the most toxic, followed by chlorpyrifos (LC50 0.11 microg/vial, fiducial limits 0.07-0.17) and acephate (LC50 0.76 microg/vial, fiducial limits 0.50-1.04). Of the chemicals assayed, it took a much higher concentration of lambda-cyhalothrin (LC50 2.30 microg/vial, fiducial limits 1.57-3.59) to kill 50% of the workers compared with the other three chemicals. The results of this study demonstrate the wide range in responses of fire ants to four insecticides that are labeled and commonly used on numerous agricultural crops throughout the United States. These results further suggest the possibility of using a discriminating dose of lambda-cyhalothrin to control the target pest species while conserving fire ants in the agricultural systems in which their predatory behavior is beneficial to the integrated pest management program.
Carignan, Courtney C; Butt, Craig M; Stapleton, Heather M; Meeker, John D; Minguez-Alarcón, Lidia; Williams, Paige L; Hauser, Russ
2017-08-01
Use of organophosphate flame retardants (PFRs) has increased over the past decade with the phase out of polybrominated diphenyl ethers. Urinary metabolites of PFRs are used as biomarkers of exposure in epidemiologic research, which typically uses samples collected and stored in polypropylene plastic cryovials. However, a small study suggested that the storage vial material may influence reported concentrations. Therefore, we aimed to examine the influence of the storage vial material on analytical measurement of PFR urinary metabolites. Using urine samples collected from participants in the Environment and Reproductive Health (EARTH) Study, we analyzed the PFR metabolites in duplicate aliquots that were stored in glass and plastic vials (n = 31 pairs). Bis(1,3-dichloro-2-propyl) phosphate (BDCIPP), diphenyl phosphate (DPHP) and isopropyl-phenyl phenyl phosphate (ip-PPP) were detected in 98%, 97% and 87% of duplicates. We observed high correlations between glass-plastic duplicates for BDCIPP (r s = 0.95), DPHP (r s = 0.79) and ip-PPP (r s = 0.82) (p < 0.0001). Urinary ip-PPP was an average of 0.04 ng/ml (p = 0.04) higher among samples stored in glass, with a mean relative difference of 14%. While this difference is statistically significant, it is small in magnitude. No differences were observed for BDCIPP or DPHP, however future research should seek to reduce the potential for type II error (false negatives). We conclude that storing urine samples in polypropylene plastic cryovials may result in slightly reduced concentrations of urinary ip-PPP relative to storage in glass vials and future research should seek to increase the sample size, reduce background variability and consider the material of the urine collection cup. Copyright © 2017 Elsevier Ltd. All rights reserved.
Results from tests of TFL Hydragard sampling loop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steimke, J.L.
When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard{reg_sign} sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the originalmore » Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause.« less
Automated method for determining Instron Residual Seal Force of glass vial/rubber closure systems.
Ludwig, J D; Nolan, P D; Davis, C W
1993-01-01
Instron Residual Seal Force (IRSF) of glass vial/rubber closure systems was determined using an Instron 4501 Materials Testing System. Computer programs were written to process raw data and calculate IRSF values. Preliminary experiments indicated both the appearance of the stress-deformation curves and precision of the derived IRSF values were dependent on the internal dimensions and top surface geometry of the cap anvil. Therefore, a series of five cap anvils varying in shape and dimensions were machined to optimize performance and precision. Vials capped with West 4416/50 PURCOAT button closures or Helvoet compound 6207 lyophilization closures were tested with each cap anvil. Cap anvils with spherical top surfaces and narrow internal dimensions produced more precise results and more uniform stress-deformation curves than cap anvils with flat top surfaces and wider internal dimensions.
Recent trends and future of pharmaceutical packaging technology
Zadbuke, Nityanand; Shahi, Sadhana; Gulecha, Bhushan; Padalkar, Abhay; Thube, Mahesh
2013-01-01
The pharmaceutical packaging market is constantly advancing and has experienced annual growth of at least five percent per annum in the past few years. The market is now reckoned to be worth over $20 billion a year. As with most other packaged goods, pharmaceuticals need reliable and speedy packaging solutions that deliver a combination of product protection, quality, tamper evidence, patient comfort and security needs. Constant innovations in the pharmaceuticals themselves such as, blow fill seal (BFS) vials, anti-counterfeit measures, plasma impulse chemical vapor deposition (PICVD) coating technology, snap off ampoules, unit dose vials, two-in-one prefilled vial design, prefilled syringes and child-resistant packs have a direct impact on the packaging. The review details several of the recent pharmaceutical packaging trends that are impacting packaging industry, and offers some predictions for the future. PMID:23833515
NASA Astrophysics Data System (ADS)
Mandic, M.; Stöbener, N.; Mandic, L.; Smajgl, D.; Jost, H. J. H.
2016-12-01
Precise and accurate determination of isotopic composition of carbon (13C) and oxygen (18O) from carbonate or DIC sample with proper referencing and data evaluation algorithm presents a challenge for scientists. Mass spectrometry was the only widely used technique for this kind of analysis, but recent advances make laser based isotope ratio infrared spectroscopy (IRIS) a viable alternative. To analyze discrete samples, the Universal Reference Interface (URI) Connect was developed. CO2 free syntethic air is used to flush out the contents of a sample container into a variable volume. If necessary, the sample is further diluted before entering the analysis chamber. Reference gas measurements are automatically performed at the same concentration as sample measurements to compensate for instrument drifts and non linearity. The URI Connect can handle about 100 samples per day from an autosampler, or samples can be injected one at a time through a septum on the front of the instrument. Gas samples collected in flasks, bags, syringes, or vials can be analyzed. The system only needs the equivalent of about 80µg - or 40µL - of pure CO2 gas to complete an analysis. Due to it's small weight and robustness, sample analysis can be performed in the field, e.g. aboard a research vessel. To demonstrate the performance, a test experiment with 1% CO2 in 12 ml vials was performed. We achieved an internal precision of better than 0.07‰ and 0.1‰ for δ13C and δ18O, respectively. Analyses with sample amounts as low as 200 μg of carbonate can also be performed reliably with IRIS. We present measurements of three international reference materials, and one of them treated as an unknown. Five samples each of approximately 1mg each were acidified using a few droplets of 43% H3PO4 and left for equilibration overnight at 25°C. The standard deviation was less than 0.1‰ δ13C and the accuracy <0.01‰ As another example of head space analysis in 12 ml vials, we determined δ18O of aliquots of 500 µl of water using equilibration with 1% CO2 in the volume above the water. The agreement with traditional IRMS methods was <0.06‰ was found.
Direct Push Chemical Sensors for DNAPL
2007-01-01
System Improvements Problem Solution 1. Insufficient thermal protection Implemented use of microporous insulation . Lab and field tests have shown...screw thread cap with Teflon lined septum. The soil and methanol were mixed by hand and the vial was placed in an insulated cooler on ice until...Teflon lined septum. The vials were stored within an insulated cooler on ice until shipped to Columbia Analytical Services for analysis by U.S. EPA
Greco, Kristyn; Mujat, Mircea; Galbally-Kinney, Kristin L; Hammer, Daniel X; Ferguson, R Daniel; Iftimia, Nicusor; Mulhall, Phillip; Sharma, Puneet; Kessler, William J; Pikal, Michael J
2013-06-01
The objective of this study was to assess the feasibility of developing and applying a laboratory tool that can provide three-dimensional product structural information during freeze-drying and which can accurately characterize the collapse temperature (Tc ) of pharmaceutical formulations designed for freeze-drying. A single-vial freeze dryer coupled with optical coherence tomography freeze-drying microscopy (OCT-FDM) was developed to investigate the structure and Tc of formulations in pharmaceutically relevant products containers (i.e., freeze-drying in vials). OCT-FDM was used to measure the Tc and eutectic melt of three formulations in freeze-drying vials. The Tc as measured by OCT-FDM was found to be predictive of freeze-drying with a batch of vials in a conventional laboratory freeze dryer. The freeze-drying cycles developed using OCT-FDM data, as compared with traditional light transmission freeze-drying microscopy (LT-FDM), resulted in a significant reduction in primary drying time, which could result in a substantial reduction of manufacturing costs while maintaining product quality. OCT-FDM provides quantitative data to justify freeze-drying at temperatures higher than the Tc measured by LT-FDM and provides a reliable upper limit to setting a product temperature in primary drying. Copyright © 2013 Wiley Periodicals, Inc.
Oxidative stress gradient in a medium during human corneal organ culture
Johnsen-Soriano, Siv; Haug, Kristiane; Arnal, Emma; Peris-Martinez, Cristina; Moe, Morten C.
2012-01-01
Purpose Lipid peroxidation content was measured in an organ culture medium after one-week storage of human donor corneas. Moreover, the effects of the medium on oxidative stress, antioxidant capacity, and the proliferation of cultured human corneal cells were studied. Methods The medium was sampled from the upper and lower halves of storage vials and from controls (n=42). Malondialdehyde (MDA) was measured by high pressure liquid chromatography (HPLC). Cultured human corneal epithelium (CRL-11515) was exposed to different medium samples and monitored for changes in MDA (enzyme-linked immunosorbent assay [ELISA]), total antioxidant capacity (antioxidant assay kit), and proliferation (Ki-67). Results A significant increase in MDA was observed in the organ culture medium in the lower level of storage vials. The addition of this fraction to cultured cells increased MDA significantly after 3 days, and the medium from both levels significantly increased MDA after 7 days. The medium from both levels significantly decreased the total antioxidant capacity of the cells but did not affect proliferative activity. Conclusions An oxidative gradient with an evident biologic effect is established in the medium in vials during organ culture of human donor corneas. Donor tissue stored at the bottom or in lower levels of such vials is exposed to a significant amount of oxidative stress. PMID:22736949
Nakashima, A K; Highsmith, A K; Martone, W J
1987-01-01
In an epidemic of septic arthritis due to Serratia marcescens, the intra-articular injection of contaminated methylprednisolone may have played a key role. The epidemic strain was found in used multiple-dose vials of methylprednisolone and in a canister of cotton balls soaked in benzalkonium chloride. The cotton balls had been used for antisepsis and disinfection. Growth characteristics of the epidemic strain of S. marcescens were compared with those of control strains of S. marcescens which had been obtained from unrelated nosocomial outbreaks. The epidemic strain was able to survive in 1:100 dilutions of benzalkonium chloride and was able to grow to greater than 10(5) CFU/ml in multiple-dose vials of methylprednisoline; control strains could not be recovered after 24 h in the same solutions. The preservative in methylprednisolone is gamma-myristyl picolinium chloride, a compound chemically related to benzalkonium chloride. We speculate that the epidemic strain of S. marcescens, which was resistant to benzalkonium chloride, had cross-resistance to gamma-myristyl picolinium chloride. If the cotton balls were used to disinfect the tops of the multiple-dose vials of methylprednisolone, small numbers of organisms subsequently introduced into the solution could have grown to high concentrations. PMID:3298309
Petritz, Olivia A; Guzman, David Sanchez-Migallon; Wiebe, Valerie J; Papich, Mark G
2013-07-01
To evaluate the stability of 3 extemporaneous oral suspensions of enrofloxacin mixed with readily available flavoring vehicles when stored at room temperature (approx 22°C). Evaluation study. 3 commonly compounded oral suspensions of enrofloxacin. On day 0, commercially available enrofloxacin tablets were compounded with a mixture of distilled water and corn syrup (formulation A) or cherry syrup (formulation B) flavoring vehicles to create suspensions with a nominal enrofloxacin concentration of 22.95 mg/mL, and 2.27% enrofloxacin injectable solution was compounded with a liquid sweetener (formulation C) to create a suspension with a nominal enrofloxacin concentration of 11.35 mg/mL. Preparations were stored in amber-colored vials at room temperature for 56 days. For each preparation, the enrofloxacin concentration was evaluated with high-performance liquid chromatography at prespecified intervals during the study. The pH, odor, and consistency for all suspensions were recorded at the start and completion of the study. Relative to the nominal enrofloxacin concentration, the enrofloxacin concentration strength ranged from 95.80% to 100.69% for formulation A, 108.44% to 111.06% for formulation B, and 100.99% to 103.28% for formulation C. A mild pH increase was detected in all 3 suspensions during the study. Results indicated that, when stored in amber-colored vials at room temperature for 56 days, the enrofloxacin concentration strength in all 3 formulations was retained within acceptance criteria of 90% to 110%. Subjectively, cherry syrup flavoring was better at masking the smell and taste of enrofloxacin than were the other mixing vehicles.
Mehta, Rohini; Baranova, Ancha; Birerdinc, Aybike
2012-01-01
Liquid nitrogen is colorless, odorless, extremely cold (-196 °C) liquid kept under pressure. It is commonly used as a cryogenic fluid for long term storage of biological materials such as blood, cells and tissues 1,2. The cryogenic nature of liquid nitrogen, while ideal for sample preservation, can cause rapid freezing of live tissues on contact - known as 'cryogenic burn'2, which may lead to severe frostbite in persons closely involved in storage and retrieval of samples from Dewars. Additionally, as liquid nitrogen evaporates it reduces the oxygen concentration in the air and might cause asphyxia, especially in confined spaces2. In laboratories, biological samples are often stored in cryovials or cryoboxes stacked in stainless steel racks within the Dewar tanks1. These storage racks are provided with a long shaft to prevent boxes from slipping out from the racks and into the bottom of Dewars during routine handling. All too often, however, boxes or vials with precious samples slip out and sink to the bottom of liquid nitrogen filled tank. In such cases, samples could be tediously retrieved after transferring the liquid nitrogen into a spare container or discarding it. The boxes and vials can then be relatively safely recovered from emptied Dewar. However, the cryogenic nature of liquid nitrogen and its expansion rate makes sunken sample retrieval hazardous. It is commonly recommended by Safety Offices that sample retrieval be never carried out by a single person. Another alternative is to use commercially available cool grabbers or tongs to pull out the vials3. However, limited visibility within the dark liquid filled Dewars poses a major limitation in their use. In this article, we describe the construction of a Cryotolerant DIY retrieval device, which makes sample retrieval from Dewar containing cryogenic fluids both safe and easy. PMID:22617806
Postemsky, Pablo Daniel; Palermo, Ana Maria; Curvetto, Néstor Raúl
2011-01-01
Grifola gargal is an edible mushroom with attributed antioxidant properties. Different sources of G. gargal materials, i.e., fruit bodies and mycelia grown in liquid or solid media, were used to study its potential protective capacity when somatic mutation and recombination is induced in Drosophila melanogaster using DMBA (7-12-dimethyl-benz(α)anthracene) as promutagen. Heterozygote larvae (white/white+) were grown in media with different concentrations of DMBA. Grifola gargal fruit bodies (GgFB) or mycelia from liquid culture (GgLC) or from solid culture (GgWG), i.e., biotransformed wheat kernel flour, were added to the culture media in combined treatments with DMBA. Water, DMBA solvent, or wheat flour (WF) plus DMBA solvent were used as negative controls. Larval mortality increased from 9% to 11% in negative controls to 31% to 36% in DMBA treatments. The addition of GgFB, GgLC, or GgWG materials produced a protective effect on 25 μmol/vial DMBA-induced mortality. Mutations observed in SMART, as light spots per 100 eyes (LS/100 eyes), increased with increasing doses of DMBA; this was also true when considering the mutation incidence expressed as percentage of eyes exhibiting light spots (% eyes with LS). Interestingly, mycelia from GgFB, GgLC, or GgWG, in the presence of 25 μmol/vial DMBA, showed lower values in SMART of both the total LS/100 eyes and the percentage of eyes with LS. Thus, Grifola gargal materials were not only nontoxic, but in combination with 25 μmol/vial DMBA lowered the mortality induced by the promutagen and showed antimutagenic effects. Protective effects of G. gargal against DMBA are discussed in terms of the onset of desmutagenic and/or bioantimutagenic mechanisms of detoxification in the host organism, probably due to some bioactive compounds known to occur in higher mushrooms.
Mehta, Rohini; Baranova, Ancha; Birerdinc, Aybike
2012-05-11
Liquid nitrogen is colorless, odorless, extremely cold (-196 °C) liquid kept under pressure. It is commonly used as a cryogenic fluid for long term storage of biological materials such as blood, cells and tissues (1,2). The cryogenic nature of liquid nitrogen, while ideal for sample preservation, can cause rapid freezing of live tissues on contact - known as 'cryogenic burn' (2), which may lead to severe frostbite in persons closely involved in storage and retrieval of samples from Dewars. Additionally, as liquid nitrogen evaporates it reduces the oxygen concentration in the air and might cause asphyxia, especially in confined spaces (2). In laboratories, biological samples are often stored in cryovials or cryoboxes stacked in stainless steel racks within the Dewar tanks (1). These storage racks are provided with a long shaft to prevent boxes from slipping out from the racks and into the bottom of Dewars during routine handling. All too often, however, boxes or vials with precious samples slip out and sink to the bottom of liquid nitrogen filled tank. In such cases, samples could be tediously retrieved after transferring the liquid nitrogen into a spare container or discarding it. The boxes and vials can then be relatively safely recovered from emptied Dewar. However, the cryogenic nature of liquid nitrogen and its expansion rate makes sunken sample retrieval hazardous. It is commonly recommended by Safety Offices that sample retrieval be never carried out by a single person. Another alternative is to use commercially available cool grabbers or tongs to pull out the vials (3). However, limited visibility within the dark liquid filled Dewars poses a major limitation in their use. In this article, we describe the construction of a Cryotolerant DIY retrieval device, which makes sample retrieval from Dewar containing cryogenic fluids both safe and easy.
Diz Dios, P; Tomás Carmona, I; Limeres Posse, J; Medina Henríquez, J; Fernández Feijoo, J; Alvarez Fernández, M
2006-09-01
We evaluated the efficacies of oral prophylactic treatment with amoxicillin (AMX), clindamycin (CLI), and moxifloxacin (MXF) in the prevention of bacteremia following dental extractions (BDE). Two hundred twenty-one adults who required dental extractions under general anesthesia were randomly assigned to a control group, an AMX group, a CLI group, and an MXF group (the individuals in the drug treatment groups received 2 g, 600 mg, and 400 mg, respectively, 1 to 2 h before anesthesia induction). Venous blood samples were collected from each patient at the baseline and 30 s, 15 min, and 1 h after the dental extractions. The samples were inoculated into BACTEC Plus aerobic and anaerobic blood culture bottles and were processed in a BACTEC 9240 instrument. Subculture and the further identification of the isolated bacteria were performed by conventional microbiological techniques. The prevalences of BDE in the control group, AMX group, CLI group, and MXF group were 96, 46, 85, and 57%, respectively, at 30 s; 64, 11, 70, and 24%, respectively, at 15 min; and 20, 4, 22, and 7%, respectively, at 1 h. Streptococcus spp. were the most frequently identified bacteria in all groups (44 to 68%), with the lowest percentage being detected in the AMX group (44%). AMX and MXF prophylaxis showed high efficacies in reducing the prevalence and duration of BDE, but CLI prophylaxis was noneffective. As a consequence, MXF prophylaxis is a promising antibiotic alternative for the prevention of BDE when beta-lactams are not indicated.
Diz Dios, P.; Tomás Carmona, I.; Limeres Posse, J.; Medina Henríquez, J.; Fernández Feijoo, J.; Álvarez Fernández, M.
2006-01-01
We evaluated the efficacies of oral prophylactic treatment with amoxicillin (AMX), clindamycin (CLI), and moxifloxacin (MXF) in the prevention of bacteremia following dental extractions (BDE). Two hundred twenty-one adults who required dental extractions under general anesthesia were randomly assigned to a control group, an AMX group, a CLI group, and an MXF group (the individuals in the drug treatment groups received 2 g, 600 mg, and 400 mg, respectively, 1 to 2 h before anesthesia induction). Venous blood samples were collected from each patient at the baseline and 30 s, 15 min, and 1 h after the dental extractions. The samples were inoculated into BACTEC Plus aerobic and anaerobic blood culture bottles and were processed in a BACTEC 9240 instrument. Subculture and the further identification of the isolated bacteria were performed by conventional microbiological techniques. The prevalences of BDE in the control group, AMX group, CLI group, and MXF group were 96, 46, 85, and 57%, respectively, at 30 s; 64, 11, 70, and 24%, respectively, at 15 min; and 20, 4, 22, and 7%, respectively, at 1 h. Streptococcus spp. were the most frequently identified bacteria in all groups (44 to 68%), with the lowest percentage being detected in the AMX group (44%). AMX and MXF prophylaxis showed high efficacies in reducing the prevalence and duration of BDE, but CLI prophylaxis was noneffective. As a consequence, MXF prophylaxis is a promising antibiotic alternative for the prevention of BDE when beta-lactams are not indicated. PMID:16940094
The Importance of Mean Neutrophil Volume (MNV) Values in Differential Diagnosis of Bacterial Sepsis.
Şafak, Birol; Baykan, Özgür; Kılınç, Osman; Özer Yıldırım, Diğdem
2017-01-01
Bloodstream infections are a significant cause of morbidity and mortality in hospitalized patients. Blood cultures and other laboratory tests are used for diagnosis. Among these tests, the mean neutrophil volume (MNV) value is reported as a potential indicator that supports the diagnosis of sepsis. Our study identified the MNV values of patients via microorganisms cultivated from blood cultures and examined the role of these MNV values in the early diagnosis of bloodstream infections. Our study surveyed retrospectively 148 adult patient blood culture samples that had been sent to our laboratory. BACTEC 9050 (Becton Dickinson, USA) and BACTEC FX 40 (Becton Dickinson, USA) devices were used in the blood culture isolation procedures. The average MNV value was found to be 159.0 (+11.3) in patients whose sepsis originated from Gram-negative bacteria, and the average MNV value was measured as 152.4 (+14.5) among patients whose sepsis originated from Gram-positive bacteria. When comparing groups of patients having Gram-negative bacteria and patients having Gram-positive bacteria, a statistically significant difference (p = 0.041) in the MNV values was observed. The MNV value was found to be statistically significant in discrimination of Gram-negative and Gram-positive sepsis. Considering these findings, measuring the MNV values can help initiate proper antibiotic treatment more quickly, and we think that this will help lower the mortality rate. However, these findings should be supported with further studies. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.
2007-05-24
0.9% sodium chloride will be prepared, dispensed, and administered intravenously to the organ donor. Subsequent to the initiation of the potassium...of methylprednisolone, 20 units of regular insulin, and 20 micrograms of levothyroxine . The dextrose and insulin are contained within vials that can...be obtained from the Pyxis pharmaceutical dispensing machine. Methylprednisolone and levothyroxine are contained in vials in the main pharmacy. Once
Collins, Jeffrey M; Hunter, Mary; Gordon, Wanda; Kempker, Russell R; Blumberg, Henry M; Ray, Susan M
2018-06-01
Following large declines in tuberculosis transmission the United States, large-scale screening programs targeting low-risk healthcare workers are increasingly a source of false-positive results. We report a large cluster of presumed false-positive tuberculin skin test results in healthcare workers following a change to 50-dose vials of Tubersol tuberculin.Infect Control Hosp Epidemiol 2018;39:750-752.
Reina, Jordi; Ballesteros, Francisca; Ruiz de Gopegui, Enrique; Munar, Maria; Mari, Margarita
2003-01-01
We report a prospective comparison of the efficacies of an indirect immunofluorescence assay (IFA) and shell vial culture (SVC) of throat swab and urine samples from patients with mumps. Throat swab samples were used for the IFA; the urine samples and throat swabs were inoculated into vials of Vero cells. We studied 62 patients by using 62 throat swabs and 50 urine samples (50 patients with both samples). Sixty (96.7%) throat samples were positive in the SVC, and 61 (98.3%) were positive in the IFA. For the 50 patients from whom both samples were available, the IFA was positive in 50 (100%) cases, the urine sample was positive in 49 (98%) cases, and the throat swab was positive in 48 (96%) cases (P > 0.05). This comparison of throat swabs and urine samples has shown that the two clinical samples are similar in efficacy. PMID:14605158
Howell, Jahna; Niu, Fengui; McCabe, Shannon E; Zhou, Wei; Decedue, Charles J
2012-06-01
A process is described using supercritical carbon dioxide to extract organic solvents from drug solutions contained in 30-mL serum vials. We report drying times of less than 1 h with quantitative recovery of sterile drug. A six-log reduction of three spore types used as biological indicators is achieved with direct addition of peracetic acid to a final concentration of approximately 5 mM (~0.04 %) to the drug solution in the vial. Analysis of two drugs, acetaminophen and paclitaxel, indicated no drug degradation as a result of the treatment. Furthermore, analysis of the processed drug substance showed that no residual peracetic acid could be detected in the final product. We have demonstrated an effective means to simultaneously dry and sterilize active pharmaceutical ingredients from organic solvents directly in a dispensing container.
Heat transfer characteristics of current primary packaging systems for pharmaceutical freeze-drying.
Hibler, Susanne; Gieseler, Henning
2012-11-01
In the field of freeze-drying, the primary packaging material plays an essential role. Here, the packaging system not only contains and protects the drug product during storage and shipping, but it is also directly involved in the freeze-drying process itself. The heat transfer characteristics of the actual container system influence product temperature and therefore product homogeneity and quality as well as process performance. Consequently, knowledge of the container heat transfer characteristics is of vital importance for process optimization. It is the objective of this review article to provide a summary of research focused on heat transfer characteristics of different container systems for pharmaceutical freeze-drying. Besides the common tubing and molded glass vials and metal trays, more recent packaging solutions like polymer vials, LYOGUARD® trays, syringes, and blister packs are discussed. Recent developments in vial manufacturing are also taken into account. Copyright © 2012 Wiley Periodicals, Inc.
Salgado, M; Steuer, P; Troncoso, E; Collins, M T
2013-12-27
Mycobacterium avium subsp. paratuberculosis (MAP) causes paratuberculosis, or Johne's disease, in animals. Diagnosis of MAP infection is challenging because of the pathogen's fastidious in vitro growth requirements and low-level intermittent shedding in feces during the preclinical phase of the infection. Detection of these "low-shedders" is important for effective control of paratuberculosis as these animals serve as sources of infection for susceptible calves. Magnetic separation technology, used in combination with culture or molecular methods for the isolation and detection of pathogenic bacteria, enhances the analytical sensitivity and specificity of detection methods. The aim of the present study was to evaluate peptide-mediated magnetic separation (PMS) capture technology coupled with IS900 PCR using the Roche real-time PCR system (PMS-PCR), in comparison with fecal culture using BACTEC-MGIT 960 system, for detection of MAP in bovine fecal samples. Among the 351 fecal samples 74.9% (263/351) were PMS-PCR positive while only 12.3% (43/351) were MGIT culture-positive (p=0.0001). All 43 MGIT culture-positive samples were also positive by PMS-PCR. Mean PMS-PCR crossing-point (Cp) values for the 13 fecal samples with the highest number of MAP, based on time to detection, (26.3) were significantly lower than for the 17 fecal samples with <100 MAP per 2g feces (30.06) (p<0.05). PMS-PCR technology provided results in a shorter time and yielded a higher number of positive results than MGIT culture. Earlier and faster detection of animals shedding MAP by PMS-PCR should significantly strengthen control efforts for MAP-infected cattle herds by helping to limit infection transmission at earlier stages of the infection. Copyright © 2013 Elsevier B.V. All rights reserved.
Macuamule, C L S; Wiid, I J; van Helden, P D; Tanner, M; Witthuhn, R C
2016-01-18
Mycobacterium bovis that causes Bovine tuberculosis (BTB) can be transmitted to humans thought consumption of raw and raw fermented milk products from diseased animals. Lactic acid bacteria (LAB) used in popular traditional milk products in Africa produce anti-microbial compounds that inhibit some pathogenic and spoilage bacteria. M. bovis BCG is an attenuated non-pathogenic vaccine strain of M. bovis and the aim of the study was to determine the effect of the fermentation process on the survival of M. bovis BCG in milk. M. bovis BCG at concentrations of 6 log CFU/ml was added to products of kefir fermentation. The survival of M. bovis BCG was monitored at 12-h intervals for 72 h by enumerating viable cells on Middlebrook 7H10 agar plates enriched with 2% BD BACTEC PANTA™. M. bovis BCG was increasingly reduced in sterile kefir that was fermented for a period of 24h and longer. In the milk fermented with kefir grains, Lactobacillus paracasei subsp. paracasei or Lactobacillus casei, the viability of M. bovis BCG was reduced by 0.4 logs after 24h and by 2 logs after 48 h of fermentation. No viable M. bovis BCG was detected after 60 h of fermentation. Results from this study show that long term fermentation under certain conditions may have the potential to inactivate M. bovis BCG present in the milk. However, to ensure safety of fermented milk in Africa, fermentation should be combined with other hurdle technologies such as boiling and milk pasteurisation. Copyright © 2015 Elsevier B.V. All rights reserved.
Bai, Ge; Bee, Jared S; Biddlecombe, James G; Chen, Quanmin; Leach, W Thomas
2012-02-28
Agitation of small amounts of liquid is performed routinely in biopharmaceutical process, formulation, and packaging development. Protein degradation commonly results from agitation, but the specific stress responsible or degradation mechanism is usually not well understood. Characterization of the agitation stress methods is critical to identifying protein degradation mechanisms or specific sensitivities. In this study, computational fluid dynamics (CFD) was used to model agitation of 1 mL of fluid by four types of common laboratory agitation instruments, including a rotator, orbital shaker, magnetic stirrer and vortex mixer. Fluid stresses in the bulk liquid and near interfaces were identified, quantified and compared. The vortex mixer provides the most intense stresses overall, while the stir bar system presented locally intense shear proximal to the hydrophobic stir bar surface. The rotator provides gentler fluid stresses, but the air-water interfacial area and surface stresses are relatively high given its low rotational frequency. The orbital shaker provides intermediate-level stresses but with the advantage of a large stable platform for consistent vial-to-vial homogeneity. Selection of experimental agitation methods with targeted types and intensities of stresses can facilitate better understanding of protein degradation mechanisms and predictability for "real world" applications. Copyright © 2011 Elsevier B.V. All rights reserved.
Pseudooutbreak of Candida guilliermondii fungemia in a neonatal intensive care unit.
Yagupsky, P; Dagan, R; Chipman, M; Goldschmied-Reouven, A; Zmora, E; Karplus, M
1991-12-01
During a 3-week period multiple blood cultures obtained from 14 Neonatal Intensive Care Unit infants and 3 Newborn Unit babies grew Candida guilliermondii, a yeast rarely associated with infections in humans. At the time of detection of positive cultures, most infants had been hospitalized for days or weeks for serious perinatal conditions and treated with antibiotics and intravenous hyperalimentation. Two critically ill premature infants from whom the yeast was isolated were given amphotericin B. In 7 other infants, however, yeasts were recovered on the day of birth, raising the question of pseudofungemia. Exhaustive interrogation on the blood culture practices revealed that when drawing blood for a culture from small infants, "butterfly" needles were often flushed with a diluted heparin solution to prevent blood clotting. Culture of a single lot of diluted heparin vials, prepared at the hospital pharmacy and distributed to the Neonatal Intensive Care Unit and Newborn Unit shortly before the onset of the epidemic, grew between 10,000 and 15,000 colony-forming units of Candida guilliermondii/ml. Removal of contaminated heparin vials and discontinuation of heparinization of needles used for blood cultures resulted in cessation of the epidemic. The present outbreak illustrates the difficulties in recognizing pseudoinfections in sick premature infants and the importance of intensive investigation and intervention during such an outbreak.
Shehata, A B; Rizk, M S; Rend, E A
2016-10-01
Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.
Lee, Yeojin; Kim, Jaejin; Lee, Sanguk; Woo, Young-Ah; Chung, Hoeil
2012-01-30
Direct transmission Raman measurements for analysis of pharmaceuticals in capsules are advantageous since they can be used to determine active pharmaceutical ingredient (API) concentrations in a non-destructive manner and with much less fluorescence background interference from the capsules themselves compared to conventional back-scattering measurements. If a single calibration model such as developed from spectra simply collected in glass vials could be used to determine API concentrations of samples contained in capsules of different colors rather than constructing individual models for each capsule color, the utility of transmission measurements would be further enhanced. To evaluate the feasibility, transmission Raman spectra of binary mixtures of ambroxol and lactose were collected in a glass vial and a partial least squares (PLS) model for the determination of ambroxol concentration was developed. Then, the model was directly applied to determine ambroxol concentrations of samples contained in capsules of 4 different colors (blue, green, white and yellow). Although the prediction performance was slightly degraded when the samples were placed in blue or green capsules, due to the presence of weak fluorescence, accurate determination of ambroxol was generally achieved in all cases. The prediction accuracy was also investigated when the thickness of the capsule was varied. Copyright © 2011 Elsevier B.V. All rights reserved.
Proton-induced x-ray fluorescence CT imaging
Bazalova-Carter, Magdalena; Ahmad, Moiz; Matsuura, Taeko; Takao, Seishin; Matsuo, Yuto; Fahrig, Rebecca; Shirato, Hiroki; Umegaki, Kikuo; Xing, Lei
2015-01-01
Purpose: To demonstrate the feasibility of proton-induced x-ray fluorescence CT (pXFCT) imaging of gold in a small animal sized object by means of experiments and Monte Carlo (MC) simulations. Methods: First, proton-induced gold x-ray fluorescence (pXRF) was measured as a function of gold concentration. Vials of 2.2 cm in diameter filled with 0%–5% Au solutions were irradiated with a 220 MeV proton beam and x-ray fluorescence induced by the interaction of protons, and Au was detected with a 3 × 3 mm2 CdTe detector placed at 90° with respect to the incident proton beam at a distance of 45 cm from the vials. Second, a 7-cm diameter water phantom containing three 2.2-diameter vials with 3%–5% Au solutions was imaged with a 7-mm FWHM 220 MeV proton beam in a first generation CT scanning geometry. X-rays scattered perpendicular to the incident proton beam were acquired with the CdTe detector placed at 45 cm from the phantom positioned on a translation/rotation stage. Twenty one translational steps spaced by 3 mm at each of 36 projection angles spaced by 10° were acquired, and pXFCT images of the phantom were reconstructed with filtered back projection. A simplified geometry of the experimental data acquisition setup was modeled with the MC TOPAS code, and simulation results were compared to the experimental data. Results: A linear relationship between gold pXRF and gold concentration was observed in both experimental and MC simulation data (R2 > 0.99). All Au vials were apparent in the experimental and simulated pXFCT images. Specifically, the 3% Au vial was detectable in the experimental [contrast-to-noise ratio (CNR) = 5.8] and simulated (CNR = 11.5) pXFCT image. Due to fluorescence x-ray attenuation in the higher concentration vials, the 4% and 5% Au contrast were underestimated by 10% and 15%, respectively, in both the experimental and simulated pXFCT images. Conclusions: Proton-induced x-ray fluorescence CT imaging of 3%–5% gold solutions in a small animal sized water phantom has been demonstrated for the first time by means of experiments and MC simulations. PMID:25652502
Proof of the Feasibility of Coherent and Incoherent Schemes for Pumping a Gamma-Ray Laser
1989-07-01
compounds held in plastic vials or cylindrical planchettes . Foils and planchertes were exposed with their faces normal to the machine center- line. The...irradiation; foils and planchettes were counted with a solid NaI(TI) detector system and vials were again studied with the well detector. Samples...P to flat planchettes , and F to metallic foils. The self-absorption corrections represent the fraction of fluorescent photons which reach the
Packaging Considerations for Biopreservation
Woods, Erik J.; Thirumala, Sreedhar
2011-01-01
Summary The packaging system chosen for biopreservation is critical for many reasons. An ideal biopreservation container system must provide for closure integrity, sample stability and ready access to the preserved material. This means the system needs to be hermetically sealed to ensure integrity of the specimen is maintained throughout processing, storage and distribution; the system must remain stable over long periods of time as many biobanked samples may be stored indefinitely; and functionally closed access systems must be used to avoid contamination upon sample withdraw. This study reviews the suitability of a new commercially available vial configuration container utilizing blood bag style closure and access systems that can be hermetically sealed and remain stable through cryopreservation and biobanking procedures. This vial based systems allow for current good manufacturing/tissue practice (cGTP) requirements during processing of samples and may provide the benefit of ease of delivery by a care giver. In this study, the CellSeal® closed system cryovial was evaluated and compared to standard screw cap vials. The CellSeal system was evaluated for durability, closure integrity through transportation and maintenance of functional viability of a cryopreserved mesenchymal stem cell model. The results of this initial proof-of-concept study indicated that the CellSeal vials are highly suitable for biopreservation and biobanking, and provide a suitable container system for clinical and commercial cell therapy products frozen in small volumes. PMID:21566715
Urrutia, H; Vidal, R; Baeza, M; Reyes, J E; Aspe, E
1997-06-01
The efficiency of organic matter degradation in attached biomass reactors depends on the suitable selection of artificial support for the retention of bacterial communities. We have studied the growth on glass and clay beads of methylaminotrophic, acetotrophic and hydrogenotrophic methanogenic bacterial communities isolated from anaerobic reactors. Bacterial counts were performed by the standard MPN technique. Experiments were performed in 50 ml vials for 12 days at 35 degrees C. Increase in the counts of methylaminotrophic and hydrogenotrophic methanogens occurred on both glass and clay beads. The latter support material also stimulated the growth rate of methylaminotrophic methanogens.
Teo, Jeanette W P; Chiang, Donald; Jureen, Roland; Lin, Raymond T P
2015-11-01
In this study, we evaluate the performance of a commercial assay, the AmpliVue HSV 1+2 Assay (Quidel), which employs HDA for the detection of both HSV-1 and HSV-2. The assay was tested on 307 clinical specimens (genital, oral, and dermal). When compared to shell vial virus culture and immunofluorescence typing of HSV, the positive percent agreement and negative percent agreement values were 98.2% and 90.9%, respectively. Excellent assay performance was demonstrated. Copyright © 2015 Elsevier Inc. All rights reserved.
Nieto, Alejandra; Roehl, Holger; Adler, Michael; Mohl, Silke
2018-05-31
Frozen-state storage and cold-chain transport are key operations in the development and commercialization of biopharmaceuticals. Nowadays, a few marketed drug products are stored (and/or) shipped under frozen conditions to ensure sufficient stability, particularly for live viral vaccines. When these products are stored in glass vials with stoppers, the elastomer of the stopper needs to be flexible enough to seal the vial at the target's lowest temperature to ensure container closure integrity and hence both sterility and safety of the drug product. The container closure integrity assessment in the frozen state (e.g., -20°C, -80°C) should include: Container Closure Integrity (CCI) of the Container Closure System (CCS) itself, impact of processing, e.g. capping process on CCI and impact of shipment and movement on CCI in the frozen state. The objective of this work was an evaluation of the impact of processing and shipment on CCI of a CCS in the frozen state. The impact on other quality attributes was not investigated. In this light, the ThermCCI method was applied to evaluate the impact of shipping stress and variable capping force on CCI of frozen vials and to evaluate the temperature limits of rubber stoppers. In conclusion, retaining CCI during cold storage is mostly a function of vial-stopper combination and temperatures below -40°C may pose a risk to the CCI of a frozen drug product. Variable capping force may have an influence on the CCI of a frozen drug product if not appropriately assessed. Regarding the impact of shipment on the CCI of glass vials, no indication was given either at room temperature, -20°C or -75°C when compared to static storage at such temperatures. Copyright © 2018, Parenteral Drug Association.
Hepatitis B virus genetic mutations and evolution in liver diseases
Shen, Tao; Yan, Xin-Min
2014-01-01
Hepatitis B virus (HBV) belongs to the genus Orthohepadnavirus of the Hepadnaviridae family and is approximately 3.2 kb in length. Owing to a lack of proofreading capacity during reverse transcription and a high replication rate, HBV exhibits as quasispecies. To detect the genetic mutations of HBV, many methods with different sensitivities and throughputs were developed. According to documentary records, HBV mutation and evolution were important vial parameters in predicting disease progression and therapeutic outcome. In this review, we separately discussed the correlation between HBV genomic mutations in four open reading frames and liver disease progression. Since some of the results were controversial from different laboratories, it remains to be seen whether functional analyses will confirm their role in modifying the course of infection. PMID:24833874
Sample Collection, Analysis, and Respirator Use With Isocyanate Paints
1990-02-01
waterbath. 4. Acetonitrile. 6. Vials, 20-m. glass, with polypropylene-lined screw 5. Deionized water . caps. 6. Pentane. 7. Vials, 4-mK glass, with screw...Evaporator, Mini-Vap. 6 port, n, eqjivalent. sodium acetate in 1 L deionized 15. Flask, filtration, 500-mt. water . Add 1 L acetonitrile. Add 16. Funnel...methanol toie 5 mi way be stored at -21 uin the dark for at least solution. four weeks. Limit peibd of storage of samler at 6. Water , distilled. 25 *C
[The art of Leonardo Da Vinci as a resource to science and the ideal of nursing care].
Nascimento, Maria Aparecida de Luca; de Brito, Isabela Jorge; Dehoul, Marcelo da Silva
2003-01-01
Theoretical reflection whose goal is to demonstrate the art a nursing team is required to show in order to perform a technical procedure for transfer of solutions from a normal vial to a microdrops vial, based on Leonardo Da Vinci's theoretical referential, inspired by his work called "Vitruvian Man", so that body harmony is kept. The authors emphasize its relationship to nursing care, viewing it from its broadest sense, and its own motto--"Science, Art and Ideal".
Riot Control Agent Decontamination: Evaluation of Commercial Products
1983-06-01
yellow crystals, m.p. 72 to 73 0 C. CN (phenacyl chloride ) was obtained from commercial sources and used without further purification. To evaluate the...vial. After waiting a suitable length of time, 1.00 ml of chloroform and ca. 100 mg of sodiur-i chloride were added to the vial and the mixture shaken...been employed in the quantitation of the same. It was initially thought that dithionite was promoting the reduction of the cyano gros in CS to amines
Sensing Impacts of the Fate of Trace Explosives Signatures Under Environmental Conditions
2010-01-01
vial with a pair of clean metal tweezers. A 10 mL aliquot of CHROMASOLV® Plus HPLC -grade acetone was dispensed on the wide surfaces of the sample...Evaporator Workstation under a nitrogen purge stream in a 50 ºC water bath and reconstituted with CHROMASOLV® HPLC -grade acetonitrile to 500 L... simultaneously on the two parallel GC columns, using a refrigerated (ɠ °C) 100-vial autosampler and two parallel auto-injectors. Column 1 (Restek 562719
Heitz, James W; Bader, Stephen O
2010-09-01
The prevalence of latex allergy is increasing in surgical patient populations. Avoidance of exposure to the allergen is essential to minimizing perioperative complications in patients suspected to be at risk. Natural rubber latex has historically been ubiquitous in medical devices containing rubber. In 1998, the Food and Drug Administration (FDA) began to require the labeling of medical devices made from natural rubber latex; since that time substantial progress has been made in identifying latex-free alternatives. However, the rubber stoppers commonly found in pharmaceutical vial closures are exempt from FDA labeling requirements. Examination of the clinical and basic science literature regarding pharmaceutical vial closures supports limiting the rubber stopper to a single needle puncture as a safer practice, with the caveat that no strategy exists for the complete elimination of risk as long as stoppers made from natural rubber latex are used in pharmaceutical vials intended for human use. Copyright © 2010 Elsevier Inc. All rights reserved.
Kotarek, Joseph; Stuart, Christine; De Paoli, Silvia H; Simak, Jan; Lin, Tsai-Lien; Gao, Yamei; Ovanesov, Mikhail; Liang, Yideng; Scott, Dorothy; Brown, Janice; Bai, Yun; Metcalfe, Dean D; Marszal, Ewa; Ragheb, Jack A
2016-03-01
Peginesatide (Omontys(®); Affymax, Inc., Cupertino, CA) was voluntarily withdrawn from the market less than a year after the product launch. Although clinical trials had demonstrated the drug to be safe and efficacious, 49 cases of anaphylaxis, including 7 fatalities, were reported not long after market introduction. Commercialization was initiated with a multiuse vial presentation, which differs in formulation from the single-use vial presentation used in phase 3 studies. Standard physical and chemical testing did not indicate any deviation from product specifications in either formulation. However, an analysis of subvisible particulates using nanoparticle tracking analysis and flow imaging revealed a significantly higher concentration of subvisible particles in the multiuse vial presentation linked to the hypersensitivity cases. Although it is unknown whether the elevated particulate content is causally related to these serious adverse events, this report illustrates the utility of characterizing subvisible particulates not captured by conventional light obscuration. Copyright © 2016. Published by Elsevier Inc.
Vaccine vial stopper performance for fractional dose delivery of vaccines.
Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin
2017-07-03
Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced-or fractional-doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery.
NASA Astrophysics Data System (ADS)
Sydoff, Marie; Stenström, Kristina
2010-04-01
The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.
Satpati, Drishty; Shinto, Ajit; Kamaleshwaran, K K; Sane, Surekha; Banerjee, Sharmila
2016-06-01
[(68)Ga]DKFZ-PSMA-11 has proved to be an important diagnostic radiotracer for targeting prostate-specific membrane antigen (PSMA) overexpression in both recurrent prostate cancer (PC) and relevant metastatic sites. However, the widespread, routine clinical use of such a potential radiopharmaceutical demands availability of a ready-to-use kit formulation to enable convenient radiopharmaceutical preparation. Herein, we report the development of a freeze-dried kit vial for the formulation of [(68)Ga]DKFZ-PSMA-11 and its clinical use in patients using a "shake-bake-inject" methodology. The freeze-dried kit vial was developed after optimization of ligand content (PSMA-11) and pH conditions. The kit was formulated using (68)Ga from two different commercially available generators. Positron emission tomography/X-ray computed tomography (PET/CT) images of PC patients were obtained using the kit-formulated radiotracer. [(68)Ga]DKFZ-PSMA-11 was prepared in >98 % radiochemical yield and purity using the freeze-dried kit vials. Kits were optimized for the preparation of four patient doses. The clinical utility was evaluated in patients with histologically confirmed prostate cancer, and the images were of good quality as well as conforming to tumor marker and clinical expectations. The development of a simple and ready-to-use freeze-dried DKFZ-PSMA-11 kit for the preparation of Ga-68-based radiotracers constitutes a major step towards the expedition of the widespread and economical screening of PC patients.
Tang, Xiaolin; Nail, Steven L; Pikal, Michael J
2006-02-10
This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperature, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45 degrees C).
Tang, Xiaolin; Nail, Steven L; Pikal, Michael J
2006-03-01
This study examines the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to evaluate product temperature during primary drying. MTM was conducted during primary drying using different vial loads, and the MTM product temperatures were compared with temperatures directly measured by thermocouples. To clarify the impact of freeze-drying load on MTM product temperatures, simulation of the MTM vapor pressure rise was performed, and the results were compared with the experimental results. The effect of product temperature heterogeneity in MTM product temperature determination was investigated by comparing the MTM product temperatures with directly measured thermocouple product temperatures in systems differing in temperature heterogeneity. Both the simulated and experimental results showed that at least 50 vials (5 mL) were needed to give sufficiently rapid pressure rise during the MTM data collection period (25 seconds) in the freeze dryer, to allow accurate determination of the product temperature. The product temperature is location dependent, with higher temperature for vials on the edge of the array and lower temperature for the vials in the center of the array. The product temperature heterogeneity is also dependent upon the freeze-drying conditions. In product temperature heterogeneous systems, MTM measures a temperature close to the coldest product temperature, even, if only a small fraction of the samples have the coldest product temperature. The MTM method is valid even at very low product temperature (-45°C).
Held, H R; Landi, S
1985-07-01
A tuberculin purified protein derivative (PPD) solution containing 0.3% phenol as a preservative was dispensed in glass vials closed with rubber stoppers fastened in three different ways, namely with Tear-off seals, Flip-off seals and partial seals. After various times of storage at 5 degrees C and 37 degrees C, the phenol content in the tuberculin solution was determined. It was found that the Flip-off seals allowed the phenol to escape at a faster rate than the Tear-off seals and that vials closed with partial seals showed the highest loss of phenol. Although these losses were much more pronounced at 37 degrees C than at 5 degrees C, the phenol content at the latter temperature was, over a period of three years, within the limits of acceptability for tuberculin products capped with Tear-off or Flip-off seals. A loss of phenol also occurred from tuberculin solution stored at -28 degrees C in vials capped with either Tear-off or partial seals. In addition to the Tear-off and Flip-off seals other seals such as the "controlled score' Flip-off seal and the Alcoa Steri-Twist cap were evaluated for their imperviousness to air. Except for the Alcoa Steri-Twist cap none of the seals we have investigated were air tight and hence entirely satisfactory to prevent losses of phenol by evaporation from tuberculin products.(ABSTRACT TRUNCATED AT 250 WORDS)
Román Ivorra, José Andrés; Ivorra, José; Monte-Boquet, Emilio; Canal, Cristina; Oyagüez, Itziar; Gómez-Barrera, Manuel
2016-01-01
The objective was to assess the influence of patients' weight in the cost of rheumatoid arthritis treatment with biologic drugs used in first line after non-adequate response to methotrexate. Pharmaceutical and administration costs were calculated in two scenarios: non-optimization and optimization of intravenous (IV) vials. The retrospective analysis of 66 patients from a Spanish 1,000 beds-hospital Rheumatology Clinic Service was used to obtain posology and weight data. The study time horizon was two years. Costs were expressed in 2013 euros. For an average 69kg-weighted patient the lowest cost corresponded to abatacept subcutaneous (SC ABA) (€21,028.09) in the scenario without IV vials optimization and infliximab (IFX) (€20,779.29) with optimization. Considering patients' weight in the scenario without IV vials optimization infliximab (IFX) was the least expensive drug in patients ranged 45-49kg, IV ABA in 50-59kg and SC ABA in patients over 60kg. With IV vials optimization IFX was the least expensive drug in patients under 69kg and SC ABA over 70kg. Assuming comparable effectiveness of biological drugs, patient's weight is a variable to consider, potentials savings could reach €20,000 in two years. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Conservation of purified protein derivative RT-23 tuberculin.
Fernández-Villar, A; Gorís, A; Otero, M; Chouciño, N; Vázquez, R; Muñoz, M J; Piñeiro, L
2004-07-01
Recommendations that purified protein derivative (PPD) RT-23 tuberculin should not be kept and used more than 24 to 48 hours after opening are rarely complied with. The aim of this study was to determine whether using PPD RT-23 tuberculin from vials that had been open for a longer time could affect results of tuberculin tests and whether the solution could become contaminated. A prospective cross-sectional study was carried out. Two tuberculin tests were simultaneously administered, one in each forearm, to adult contacts of patients with active tuberculosis, one test using a recently opened vial of tuberculin (control) and the other using tuberculin that had been opened a week before (first phase) or a month before (second phase) (study tuberculin). Leftover tuberculin from several of the vials was cultured. For the 127 patients in the first group (tuberculin opened 1 week), the mean (SD) diameter of the induration was 6.2 (6.9) mm for the study tuberculin and 6.3 (6.9) mm for the control (P=.3). For the 83 patients in the second group (tuberculin opened 1 month), the mean diameter of the induration was 5.5 (7.3) mm for the study tuberculin and 5.7 (7.3) mm for the control (P=.5). There were no differences between the number of positive tests found. None of the cultured tuberculins produced bacterial growth. PPD RT-23 tuberculin does not appear to lose potency or sterility when vials have been opened for a week or a month.
Breindahl, Torben; Evans-Brown, Michael; Hindersson, Peter; McVeigh, Jim; Bellis, Mark; Stensballe, Allan; Kimergård, Andreas
2015-02-01
New methods were developed and validated to determine the identity, contents, and purity of samples of melanotan II, a synthetic melanocortin receptor agonist, sold in vials as injectable skin-tanning products that were purchased from three online shops. Methods were based on liquid chromatography with ultra-violet detection (LC-UV) at wavelength 218 nm, and tandem mass spectrometric detection (MS/MS) after collision-induced fragmentation of the double charged [M+2H](2+) precursor ion (m/z 513). Identification of melanotan II was verified by correct chromatographic retention time, and relative abundance ratios of five qualifying fragment ions. LC-UV was used to quantify melanotan II as well as impurities. Method validation was performed with reference to guidelines for assessing active substances in authorized medicinal products to reach acceptable accuracy and precision. Vials from two shops contained unknown impurities ranging from 4.1 to 5.9%; impurities from one shop were below the quantification limit. The total amount of melanotan II in vials ranged between 4.32 and 8.84 mg, although each shop claimed that vials contained 10 mg melanotan II. A broad range of drugs used for enhancement purposes can be obtained from the illicit market. However, users of these drugs may be exposed to a range of potential harms, as shown in this study, given that these products are manufactured, distributed and supplied from an illicit market. Copyright © 2014 John Wiley & Sons, Ltd.
Coorevits, L; Van den Abeele, A-M
2015-07-01
The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.
Maurya, A K; Singh, A K; Kumar, M; Umrao, J; Kant, S; Nag, V L; Kushwaha, R A S; Dhole, T N
2013-01-01
India has a high burden of drug-resistant tuberculosis (TB), although there is little data on multidrug-resistant tuberculosis (MDR-TB). Although MDR-TB has existed for long time in India, very few diagnostic laboratories are well-equipped to test drug sensitivity. The objectives of this study were to determine the prevalence of MDR-TB, first-line drug resistance patterns and its changing trends in northern India in the 4 years. This was a prospective study from July 2007 to December 2010. Microscopy, culture by Bactec460 and p-nitro-α-acetylamino-β-hydroxypropiophenone (NAP) test was performed to isolate and identify Mycobacterium tuberculosis (M. tb) complex (MTBC). Drug sensitivity testing (DST) was performed by 1% proportional method (Bactec460) for four drugs: Rifampicin, isoniazid, ethambutol and streptomycin. Various clinical and demographical profiles were evaluated to analyse risk factors for development of drug resistance. We found the overall prevalence rate of MDR-TB to be 38.8%, increasing from 36.4% in 2007 to 40.8% in 2010. we found that the prevalence of MDR-TB in new and previously treated cases was 29.1% and 43.3% ( P < 0.05; CI 95%). The increasing trend of MDR-TB was more likely in pulmonary TB when compared with extra-pulmonary TB ( P < 0.05; CI 95%). we found a high prevalence (38.8%) of MDR-TB both in new cases (29.1%) and previously treated cases (43.3%).This study strongly highlights the need to make strategies for testing, surveillance, monitoring and management of such drug-resistant cases.
Vieregg, Jeffrey R; Martin, Steven J; Breeland, Adam P; Weikart, Christopher M; Tirrell, Matthew V
2018-01-01
For many years, glass has been the default material for parenteral packaging, but the development of advanced plastics such as cyclic olefin polymers and the rapidly increasing importance of biologic drugs have provided new choices, as well as more stringent performance requirements. In particular, many biologics must be stored at non-neutral pH, where glass is susceptible to hydrolysis, metal extraction, and delamination. Plastic containers are not susceptible to these problems, but suffer from higher gas permeability and a propensity for sterilization-induced radical generation, heightening the risk of oxidative damage to sensitive drugs. This study evaluates the properties of a hybrid material, SiOPlas™, in which an ultrathin multilayer coating is applied to the interior of cyclic olefin polymer containers via plasma-enhanced chemical vapor deposition. Our results show that the coating decreases oxygen permeation through the vial walls 33-fold compared to uncoated cyclic olefin polymers, which should allow for improved control of oxygen levels in sensitive formulations. We also measured degradation of two biologic drugs that are known to be sensitive to oxidation, teriparatide and erythropoietin, in gamma and electron beam sterilized SiOPlas™, glass, and uncoated cyclic olefin polymer vials. In both cases, solutions stored in SiOPlas™ vials did not show elevated susceptibility to oxidation compared to either glass or unsterilized controls. Taken together, these results suggest that hybrid materials such as SiOPlas™ are attractive choices for storing high-value biologic drugs. LAY ABSTRACT: One of the most important functions of parenteral drug containers is safeguarding their contents from damage, either chemical or physical. Glass has been the container material of choice for many years, but concerns over breakage and vulnerability to chemical attack at non-neutral pH have spurred the rise of advanced plastics as alternatives. Plastics solve many problems associated with glass but introduce several of their own, including increased gas permeation and generation of oxidizing radicals during sterilization. In this article, we evaluate SiOPlas™, a hybrid material consisting of plastic with a thin multilayer coating applied to the interior, for its ability to overcome these two problems. We find that SiOPlas™ is much less permeable to oxygen than uncoated plastic, and that two biologic drugs stored in gamma and electron beam sterilized SiOPlas™ vials do not display elevated levels of oxidation compared to either glass or unsterilized vials. This suggests that hybrid materials such as SiOPlas™ can exhibit the best qualities of both glass and plastic, making them attractive materials for storing high-value parenteral drugs. © PDA, Inc. 2018.
Patel, Jayshree; Mulhall, Brian; Wolf, Heinz; Klohr, Steven; Guazzo, Dana Morton
2011-01-01
A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated for container-closure integrity verification of a lyophilized product in a parenteral vial package system. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Method development and optimization challenge studies incorporated artificially defective packages representing a range of glass vial wall and sealing surface defects, as well as various elastomeric stopper defects. Method validation required 3 days of random-order replicate testing of a test sample population of negative-control, no-defect packages and positive-control, with-defect packages. Positive-control packages were prepared using vials each with a single hole laser-drilled through the glass vial wall. Hole creation and hole size certification was performed by Lenox Laser. Validation study results successfully demonstrated the vacuum decay leak test method's ability to accurately and reliably detect those packages with laser-drilled holes greater than or equal to approximately 5 μm in nominal diameter. All development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work. A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated to detect defects in stoppered vial packages containing lyophilized product for injection. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Test method validation study results proved the method capable of detecting holes laser-drilled through the glass vial wall greater than or equal to 5 μm in nominal diameter. Total test time is less than 1 min per package. All method development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work.
Smith, Geoff; Arshad, Muhammad Sohail; Polygalov, Eugene; Ermolina, Irina
2013-11-01
Impedance spectroscopy has been used for the measurement of the glass transition of a 10 % maltodextrin solution contained within a glass vial, with externally attached electrodes. Features of the pseudo-relaxation process, associated with the composite impedance of the glass vial-solution assembly, were characterised by the peak amplitude, C(peak)(″), and peak frequency, f(peak), of the capacitance spectra and the equivalent circuit elements that model the impedance spectra (i.e. the solution resistance and solution capacitance) and monitored every 3 min during re-heating of the solution. The time derivatives of all four parameters studied provided a glass transition in close agreement with DSC measurements (-17 °C) and at a precision of ± 0.5 °C. The temperature dependencies of the solution resistance and peak frequency were then characterised with the Arrhenius and Vogel-Fulcher-Tammann fit functions, at temperatures below and above Tg, respectively. The energy of activation (below Tg) was estimated at ~20 kJ mol(-1), and the fragility index (If) of the glass forming liquid (above Tg) was estimated at 0.9. The significance of the fragility index to the development, optimisation and control of the freeze-drying cycle is highlighted. Copyright © 2013 Elsevier B.V. All rights reserved.
Hagedorn, Martin; Bögershausen, Ansgar; Rischer, Matthias; Schubert, Rolf; Massing, Ulrich
2017-09-15
The development of nanosuspensions of poorly soluble APIs takes a lot of time and high amount of active material is needed. In this publication the use of dual centrifugation (DC) for an effective and rapid API-nanomilling is described for the first time. DC differs from normal centrifugation by an additional rotation of the samples during centrifugation, resulting in a very fast and powerful movement of the samples inside the vials, which - in combination with milling beads - result in effective milling. DC-nanomilling was compared to conventional wet ball milling and results in same or even smaller particle sizes. Also drug concentrations up to 40% can be processed. The process is fast (typical 90min) and the temperature can be controlled. DC-nanomilling appears to be very gentle, experiments showed no change of the crystal structure during milling. Since batch sizes are very small (100-1000mg) and since 40 sample vials can be processed in parallel, DC is ideal for the screening of suitable polymer/surfactant combinations. Fenofibrate was used to investigate DC-nanomilling for formulation screening by applying a DoE-approach. The presented data also show that the results of DC-nanomilling experiments are highly comparable to the results obtained by common agitator mills. Copyright © 2017 Elsevier B.V. All rights reserved.
Scutellà, Bernadette; Trelea, Ioan Cristian; Bourlès, Erwan; Fonseca, Fernanda; Passot, Stephanie
2018-07-01
During the primary drying step of the freeze-drying process, mass transfer resistance strongly affects the product temperature, and consequently the final product quality. The main objective of this study was to evaluate the variability of the mass transfer resistance resulting from the dried product layer (R p ) in a manufacturing batch of vials, and its potential effect on the product temperature, from data obtained in a pilot scale freeze-dryer. Sublimation experiments were run at -25 °C and 10 Pa using two different freezing protocols: with spontaneous or controlled ice nucleation. Five repetitions of each condition were performed. Global (pressure rise test) and local (gravimetric) methods were applied as complementary approaches to estimate R p . The global method allowed to assess variability of the evolution of R p with the dried layer thickness between different experiments whereas the local method informed about R p variability at a fixed time within the vial batch. A product temperature variability of approximately ±4.4 °C was defined for a product dried layer thickness of 5 mm. The present approach can be used to estimate the risk of failure of the process due to mass transfer variability when designing freeze-drying cycle. Copyright © 2018 Elsevier B.V. All rights reserved.
Cryoradiation sterilization—Contemporary state and outlook
NASA Astrophysics Data System (ADS)
Talrose, V. L.; Trofimov, V. I.
1995-02-01
The new approach of radiation sterilization — cryoradiosterilization with programmed freezing — was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc.
Fundamental Investigations of the Tribological Properties of Biological Interfaces
2007-11-01
flat at the bottom of a septum-sealed vial that was purged with nitrogen gas. Into this vial, dry, distilled toluene, and 0.1 mL each of...allowed to polymerize with o-Si " 0’r +N .N+-- O ___0 stirring at 60-75 C for 43 hours. The 0 CN 2. Soxhlet extraction reaction was terminated by exposure 3...with THF to air. The PS-modified silicon wafer CN - 4 was washed by Soxhlet extraction 4- in THF for 44 hours to remove any 0 free polymer. Scheme 1
de Blois, Erik; Chan, Ho Sze; de Zanger, Rory; Konijnenberg, Mark; Breeman, Wouter A P
2014-02-01
For the sake of safety it would be desirable to store and transport the ready-for-use liquid formulation (diagnostics and therapeutics) of radiolabelled peptides. The use of ethanol, in combination with a mixture of gentisic- and ascorbic acid, has superior effects on stabilizing radiolabelled somatostatin analogs. As a consequence, (111)In- and (177)Lu-labelled somatostatin analogs can be stored and transported in a single-vial ready-for-use liquid formulation up to 7 days after radiolabelling. © 2013 Published by Elsevier Ltd.
Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh
2018-01-01
An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.
Hofko, Marjeta; Hamilton, Fiona; Mackenzie, Laura; Zimmermann, Stefan; Templeton, Kate
2015-01-01
We evaluated the performance of the BD Max StaphSR assay for the direct detection of Staphylococcus aureus from blood culture medium. In a two-center trial, 155 blood cultures from the BD Bactec FX system and 212 from the bioMérieux BacT/Alert system were tested; 170 bottles yielded S. aureus, and all were identified correctly by the BD Max StaphSR assay. The assay required approximately 2.5 h, thus allowing rapid identification of blood cultures flagged positive. PMID:26292311
Auditing smear microscopy results according to time to detection using the BACTEC™ MGIT™ TB system.
Elsaghier, A A F
2015-09-01
Smear microscopy is a rapid method for the identification of the most infectious patients with mycobacterial infection. Suboptimal smear microscopy may significantly compromise or delay patient isolation and contact tracing. A stringent method for auditing mycobacterial smear results is thus needed. This article proposes an auditing tool based on time to detection (TTD) of culture-positive samples using the automated BACTEC™ MGIT™ 960 TB system. In our study, sputum samples subjected to liquefaction and concentration before staining with a TTD of ≤ 13 days using the BACTEC system should be positive on smear microscopy.
Stability of Ertapenem 100 mg/mL in Manufacturer’s Glass Vials or Syringes at 4°C and 23°C
Walker, Scott E; Law, Shirley; Perks, William; Iazzetta, John
2015-01-01
Background: Prophylactic administration of ertapenem as a single 1-g IV dose has been shown to reduce sepsis after prostate biopsy. Objective: To evaluate the stability of ertapenem after reconstitution with 0.9% sodium chloride to a final concentration of 100 mg/mL and storage in the manufacturer’s original glass vials or polypropylene syringes. Methods: On study day 0, 100 mg/mL solutions of ertapenem were retained in the manufacturer’s glass vials or packaged in polypropylene syringes and stored at 4°C or 23°C without protection from fluorescent room light. Samples were assayed periodically over 18 days using a validated, stability-indicating liquid chromatographic method with ultra-violet detection. A beyond-use date was determined as the time for the concentration to decline to 90% of the initial (day 0) concentration, based on the fastest degradation rate, with 95% confidence. Results: Reconstituted solutions stored in the manufacturer’s glass vials or polypropylene syringes exhibited a first-order degradation rate, such that 10% of the initial concentration was lost in the first 2.5 days when stored at 4°C or within the first 6.75 h when stored at room temperature (23°C). Analysis of variance showed differences in the percentage remaining due to temperature (p < 0.001) and study day (p < 0.001) but not type of container (p = 0.98). When a 95% CI for the degradation rate was calculated and used to determine a beyond-use date, it was established that more than 90% of the initial concentration would remain for 2.35 days at 4°C and for 0.23 day (about 5 h, 30 min) at room temperature. Conclusions: A 100 mg/mL ertapenem solution stored in the manufacturer’s glass vial or a polypropylene syringe will retain more than 90.5% of the initial concentration when stored for 48 h at 4°C and for an additional 1 h at 23°C. PMID:25964683
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lakshmanan, M; Symons, R; Cork, T
Purpose: To demonstrate the feasibility of in vivo three-material decomposition techniques using photon-counting CT (PCCT) with possible advantage of resolving arterial and venous flow of an organ simultaneously. Methods: Abdominal PCCT scans were acquired using a prototype whole-body PCCT with four energy thresholds (25/50/75/90keV) in a canine. Bismuth subsalicylate (60 mg) was administered orally one day prior to scanning. Immediately prior to CT scan, gadoteric acid (60 ml, Dotarem, Guerbet) was intravenously injected, followed in ten minutes by a 20mL injection of iodinated contrast (iopamidol 370 mg/mL, Bracco). Scans were acquired every ∼20 seconds, starting from the time of iodinemore » injection. Linear material decomposition was performed using the least mean squares method to create concentration maps of iodine, gadolinium, and bismuth. The method was calibrated to vials with known concentrations of materials placed next to the animal. The accuracy of this method was tested on vials with known concentrations. Results: The material decomposition algorithm’s accuracy was confirmed to be within ±4mM in the test vials. In the animal, we could estimate the concentration of gadolinium in delayed-enhanced phase (10 minutes post-injection) in the abdomen. We could follow the wash-in and wash-out of iodine in arterial, venous, and excretory flow of the kidneys (20s, 80s, and 120s post-iodine injection) while gadolinium was present in the delayed-enhanced phase. Bismuth, which was used as a contrast agent for the gastro-intestinal tract, was easily differentiable from the other two contrast agents in the small intestine. Conclusion: This study shows the feasibility of using photon-counting CT with four energy thresholds to differentiate three k-edge contrast agents in vivo. This can potentially reduce radiation dose to patients by combining arterial and venous phases into a single acquisition.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeltchan, R., E-mail: r.zelchan@yandex.ru; Medvedeva, A.; Sinilkin, I.
Purpose: to study the potential utility of 1-thio-D-glucose labeled with {sup 99m}Tc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of {sup 99m}Tc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with {sup 99m}Tc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normalmore » and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of {sup 99m}Tc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with {sup 99m}Tc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of {sup 99m}Tc-1-thio-D-glucose at the tumor site. The accumulation of {sup 99m}Tc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that {sup 99m}Tc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of {sup 99m}Tc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.« less
NASA Astrophysics Data System (ADS)
Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.; Dergilev, A.
2016-06-01
Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 minutes at room temperature. After centrifugation of the vials with cells, the supernatant was removed. Radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B 1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 minutes. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D- glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3±0.15MBq and 1.07±0.6MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio- D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.
NASA Astrophysics Data System (ADS)
Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.
2016-08-01
Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio-D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.
Stability of live attenuated rotavirus vaccine with selected preservatives and primary containers.
Lal, Manjari; Jarrahian, Courtney; Zhu, Changcheng; Hosken, Nancy A; McClurkan, Chris L; Koelle, David M; Saxon, Eugene; Roehrig, Andrew; Zehrung, Darin; Chen, Dexiang
2016-05-11
Rotavirus infection, which can be prevented by vaccination, is responsible for a high burden of acute gastroenteritis disease in children, especially in low-income countries. An appropriate formulation, packaging, and delivery device for oral rotavirus vaccine has the potential to reduce the manufacturing cost of the vaccine and the logistical impact associated with introduction of a new vaccine, simplify the vaccination procedure, and ensure that the vaccine is safely and accurately delivered to children. Single-dose prefilled presentations can be easy to use; however, they are typically more expensive, can be a bottleneck during production, and occupy a greater volume per dose vis-à-vis supply chain storage and medical waste disposal, which is a challenge in low-resource settings. Multi-dose presentations used thus far have other issues, including increased wastage of vaccine and the need for separate delivery devices. In this study, the goals were to evaluate both the technical feasibility of using preservatives to develop a liquid multi-dose formulation and the primary packaging alternatives for orally delivered, liquid rotavirus vaccines. The feasibility evaluation included evaluation of commonly used preservatives for compatibility with rotavirus vaccines and stability testing of rotavirus vaccine in various primary containers, including Lameplast's plastic tubes, BD's oral dispenser version of Uniject™ (Uniject DP), rommelag's blow-fill-seal containers, and MEDInstill's multi-dose vial and pouch. These presentations were compared to a standard glass vial. The results showed that none of the preservatives tested were compatible with a live attenuated rotavirus vaccine because they had a detrimental effect on the viability of the virus. In the presence of preservatives, vaccine virus titers declined to undetectable levels within 1 month. The vaccine formulation without preservatives maintained a stability profile over 12 months in all primary containers that was similar to its profile in standard glass vials. This study demonstrates that there are multiple options for the primary container for rotavirus vaccines intended for oral delivery. Selection of an optimal primary container should take into consideration additional factors, including stability as well as cold chain volume, usability, cost, and manufacturing feasibility. Copyright © 2016. Published by Elsevier Ltd.
Patient and parent preferences for characteristics of prophylactic treatment in hemophilia
Furlan, Roberto; Krishnan, Sangeeta; Vietri, Jeffrey
2015-01-01
Introduction New longer-acting factor products will potentially allow for less frequent infusion in prophylactic treatment of hemophilia. However, the role of administration frequency relative to other treatment attributes in determining preferences for prophylactic hemophilia treatment regimens is not well understood. Aim To identify the relative importance of frequency of administration, efficacy, and other treatment characteristics among candidates for prophylactic treatment for hemophilia A and B. Method An Internet survey was conducted among hemophilia patients and the parents of pediatric hemophilia patients in Australia, Canada, and the US. A monadic conjoint task was included in the survey, which varied frequency of administration (three, two, or one time per week for hemophilia A; twice weekly, weekly, or biweekly for hemophilia B), efficacy (no bleeding or breakthrough bleeding once every 4 months, 6 months, or 12 months), diluent volume (3 mL vs 2.5 mL for hemophilia A; 5 mL vs 3 mL for hemophilia B), vials per infusion (2 vs 1), reconstitution device (assembly required vs not), and manufacturer (established in hemophilia vs not). Respondents were asked their likelihood to switch from their current regimen to the presented treatment. Respondents were told to assume that other aspects of treatment, such as risk of inhibitor development, cost, and method of distribution, would remain the same. Results A total of 89 patients and/or parents of children with hemophilia A participated; another 32 were included in the exercise for hemophilia B. Relative importance was 47%, 24%, and 18% for frequency of administration, efficacy, and manufacturer, respectively, in hemophilia A; analogous values were 48%, 26%, and 21% in hemophilia B. The remaining attributes had little impact on preferences. Conclusion Patients who are candidates for prophylaxis and their caregivers indicate a preference for reduced frequency of administration and high efficacy, but preferences were more sensitive to administration frequency than small changes in annual bleeding rate. PMID:26648701
Rambhatla, S; Tchessalov, S; Pikal, Michael J
2006-04-21
The objective of this research was to estimate differences in heat and mass transfer between freeze dryers due to inherent design characteristics using data obtained from sublimation tests. This study also aimed to provide guidelines for convenient scale-up of the freeze-drying process. Data obtained from sublimation tests performed on laboratory-scale, pilot, and production freeze dryers were used to evaluate various heat and mass transfer parameters: nonuniformity in shelf surface temperatures, resistance of pipe, refrigeration system, and condenser. Emissivity measurements of relevant surfaces such as the chamber wall and the freeze dryer door were taken to evaluate the impact of atypical radiation heat transfer during scale-up. "Hot" and "cold" spots were identified on the shelf surface of different freeze dryers, and the impact of variation in shelf surface temperatures on the primary drying time and the product temperature during primary drying was studied. Calculations performed using emissivity measurements on different freeze dryers suggest that a front vial in the laboratory lyophilizer received 1.8 times more heat than a front vial in a manufacturing freeze dryer operating at a shelf temperature of -25 degrees C and a chamber pressure of 150 mTorr during primary drying. Therefore, front vials in the laboratory are much more atypical than front vials in manufacturing. Steady-state heat and mass transfer equations were used to study a combination of different scale-up issues pertinent during lyophilization cycles commonly used for the freeze-drying of pharmaceuticals.
A new tritiated water measurement method with plastic scintillator pellets.
Furuta, Etsuko; Iwasaki, Noriko; Kato, Yuka; Tomozoe, Yusuke
2016-01-01
A new tritiated water measurement method with plastic scintillator pellets (PS-pellets) by using a conventional liquid scintillation counter was developed. The PS-pellets used were 3 mm in both diameter and length. A low potassium glass vial was filled full with the pellets, and tritiated water was applied to the vial from 5 to 100 μl. Then, the sample solution was scattered in the interstices of the pellets in a vial. This method needs no liquid scintillator, so no liquid organic waste fluid is generated. The counting efficiency with the pellets was approximately 48 % when a 5 μl solution was used, which was higher than that of conventional measurement using liquid scintillator. The relationship between count rate and activity showed good linearity. The pellets were able to be used repeatedly, so few solid wastes are generated with this method. The PS-pellets are useful for tritiated water measurement; however, it is necessary to develop a new device which can be applied to a larger volume and measure low level concentration like an environmental application.
ssDNA degradation along capillary electrophoresis process using a Tris buffer.
Ric, Audrey; Ong-Meang, Varravaddheay; Poinsot, Verena; Martins-Froment, Nathalie; Chauvet, Fabien; Boutonnet, Audrey; Ginot, Frédéric; Ecochard, Vincent; Paquereau, Laurent; Couderc, François
2017-06-01
Tris-Acetate buffer is currently used in the selection and the characterization of ssDNA by capillary electrophoresis (CE). By applying high voltage, the migration of ionic species into the capillary generates a current that induces water electrolysis. This phenomenon is followed by the modification of the pH and the production of Tris derivatives. By injecting ten times by capillary electrophoresis ssDNA (50 nM), the whole oligonucleotide was degraded. In this paper, we will show that the Tris buffer in the running vials is modified along the electrophoretic process by electrochemical reactions. We also observed that the composition of the metal ions changes in the running buffer vials. This phenomenon, never described in CE, is important for fluorescent ssDNA analysis using Tris buffer. The oligonucleotides are degraded by electrochemically synthesized species (present in the running Tris vials) until it disappears, even if the separation buffer in the capillary is clean. To address these issues, we propose to use a sodium phosphate buffer that we demonstrate to be electrochemically inactive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A fully automated liquid–liquid extraction system utilizing interface detection
Maslana, Eugene; Schmitt, Robert; Pan, Jeffrey
2000-01-01
The development of the Abbott Liquid-Liquid Extraction Station was a result of the need for an automated system to perform aqueous extraction on large sets of newly synthesized organic compounds used for drug discovery. The system utilizes a cylindrical laboratory robot to shuttle sample vials between two loading racks, two identical extraction stations, and a centrifuge. Extraction is performed by detecting the phase interface (by difference in refractive index) of the moving column of fluid drawn from the bottom of each vial containing a biphasic mixture. The integration of interface detection with fluid extraction maximizes sample throughput. Abbott-developed electronics process the detector signals. Sample mixing is performed by high-speed solvent injection. Centrifuging of the samples reduces interface emulsions. Operating software permits the user to program wash protocols with any one of six solvents per wash cycle with as many cycle repeats as necessary. Station capacity is eighty, 15 ml vials. This system has proven successful with a broad spectrum of both ethyl acetate and methylene chloride based chemistries. The development and characterization of this automated extraction system will be presented. PMID:18924693
Vaccine vial stopper performance for fractional dose delivery of vaccines
Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin
2017-01-01
ABSTRACT Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced—or fractional—doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery. PMID:28463054
Runes, H B; Jenkins, J J; Field, J A
1999-08-01
Triadimefon, a fungicide, and ethofumesate, an herbicide, are commonly applied to turfgrass in the Pacific Northwest, resulting in foliar residues. A simple and rapid method was developed to determine triadimefon and ethofumesate concentrations from dislodgeable foliar residues on turfgrass. Turfgrass samples were washed, and wash water containing surfactant (a 0.126% solution) was collected for residue analysis. This analytical method utilizes a 25 mm C(8) Empore disk and in-vial elution to quantitatively determine triadimefon and ethofumesate in 170 mL aqueous samples. The analytes were eluted by placing the disk in a 2 mL autosampler vial with 980 microL of ethyl acetate and 20 microL of 2-chlorolepidine, the internal standard, for analysis by GC/MS. The method quantitation limits are 0.29 microg/L for ethofumesate and 0.59 microg/L for triadimefon. The method detection limits are 0.047 microg/L and 0.29 microg/L for ethofumesate and triadimefon, respectively. Concentrations of triadimefon and ethofumesate from dislodgeable foliar residues from a field study are reported.
Lam, Philippe; Stern, Al
2010-01-01
We developed several techniques for visualizing the fit between a stopper and a vial in the critical flange area, a location typically hidden from view. Using these tools, it is possible to identify surfaces involved in forming the initial seal immediately after stopper insertion. We present examples illustrating important design elements that can contribute to forming a robust primary package. These techniques can also be used for component screening by facilitating the identification of combinations that do not fit well together so that they can be eliminated early in the selection process.
2011-02-01
30 °C Stock vials were prepared following standard microbial protocol. A single colony from the overnight nutrient agar plate was inoculated into...500-mL seed cultures were prepared by inoculating with 2 vials of frozen stock and incubating at 30 °C and 200 rpm until the OD reached approximately...and OD profiles vs. elapsed fermentation time ( EFT ) from 20- and 1000-L scales are shown in Figure 9. In both runs, no DO limitation was apparent, and
Cook, Isobel Ann; Ward, Kevin Richard
2011-01-01
We compare frequency modulation spectroscopy (FMS) as a method of headspace water analysis with the method of Karl Fischer coulometric titration (KF), which is widely used in the analysis of residual water in a freeze-dried material. Parameters relating to the type of formulation (amorphous, crystalline) and the freeze-drying cycle (temperature, pressure, time) were investigated in relation to the resulting headspace moisture (HSM) and total water. We describe the effect of stopper treatment and storage conditions on the HSM levels observed using FMS as a non-destructive method, which also allowed individual vials to be reanalyzed at a series of time points as part of a long-term monitoring exercise. The results of this study enabled a better understanding of the effect of stopper type and pre-lyophilization treatment on the HSM levels both immediately after freeze-drying and upon subsequent storage of the sealed vials of lyophilized material at different temperatures. A clear, linear relationship was observed between HSM and KF values for vials containing freeze-dried sucrose, implying a relatively straightforward interaction between water and the lyophilized cake for this material. Moisture mapping of all vials on one shelf of the freeze-dryer enabled further information to be obtained on the relationship of the formulation, vial, process conditions, equipment geometry, and performance on the intra-batch variability in HSM level and dynamics. It is believed that this could therefore represent a potentially useful technique for quality assurance and in the validation of lyophilization cycles, equipment, and scale-up. Lyophilization, also known as "freeze-drying," is a relatively old technique that has been used in its most basic form for thousands of years (e.g., preservation of fish and meat products). In its more advanced form it is used to preserve many medical products, for example, many vaccines are not stable in solution and therefore need to be dried to allow long-term storage. In order to produce a freeze-dried vaccine a complex understanding of the processes and critical temperatures is required. Once these have been understood the material is dried to give relatively low moisture content (e.g., 2% w/w). This low moisture content is critical for the long-term stability of the product, allowing doctors/chemists to store these goods on site for use when required. This research paper provides further information on a technique called frequency modulation spectroscopy (FMS) that could be used to further our knowledge of the water dynamics within a freeze-dried product, enabling us to increase our understanding of the role various materials and processing conditions play; this in turn could assist in improving quality assurance and ultimately the final product that reaches the consumer.
de Cueto, Marina; Ceballos, Esther; Martinez-Martinez, Luis; Perea, Evelio J.; Pascual, Alvaro
2004-01-01
In order to further decrease the time lapse between initial inoculation of blood culture media and the reporting of results of identification and antimicrobial susceptibility tests for microorganisms causing bacteremia, we performed a prospective study in which specially processed fluid from positive blood culture bottles from Bactec 9240 (Becton Dickinson, Cockeysville, Md.) containing aerobic media were directly inoculated into Vitek 2 system cards (bio-Mérieux, France). Organism identification and susceptibility results were compared with those obtained from cards inoculated with a standardized bacterial suspension obtained following subculture to agar; 100 consecutive positive monomicrobic blood cultures, consisting of 50 gram-negative rods and 50 gram-positive cocci, were included in the study. For gram-negative organisms, 31 of the 50 (62%) showed complete agreement with the standard method for species identification, while none of the 50 gram-positive cocci were correctly identified by the direct method. For gram-negative rods, there were 50% categorical agreements between the direct and standard methods for all drugs tested. The very major error rate was 2.4%, and the major error rate was 0.6%. The overall error rate for gram-negatives was 6.6%. Complete agreement in clinical categories of all antimicrobial agents evaluated was obtained for 19 of 50 (38%) gram-positive cocci evaluated; the overall error rate was 8.4%, with 2.8% minor errors, 2.4% major errors, and 3.2% very major errors. These findings suggest that the Vitek 2 cards inoculated directly from positive Bactec 9240 bottles do not provide acceptable bacterial identification or susceptibility testing in comparison with corresponding cards tested by a standard method. PMID:15297523
Bruins, Marjan J.; Bloembergen, Peter; Ruijs, Gijs J. H. M.; Wolfhagen, Maurice J. H. M.
2004-01-01
Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the “gold standard.” We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture. PMID:14715724
CHROMagar Candida Medium for Direct Susceptibility Testing of Yeast from Blood Cultures
Tan, Grace L.; Peterson, Ellena M.
2005-01-01
An evaluation was performed on 95 blood cultures positive for Candida spp. to determine the correlation of direct susceptibility testing of fluconazole versus both standardized disk diffusion and MIC methods. For direct testing, an aliquot taken from BD BACTEC Plus and/or BD BACTEC Lytic/10 bottles (Becton Dickinson [BD], Sparks, MD) positive by gram stain for yeast was subcultured to CHROMagar Candida (BD), and a 25-μg fluconazole disk (BD) was placed on the plate. The area of growth inhibition surrounding the disk was measured at 24 and 48 h. In addition, a subculture of the isolate was tested by a microdilution MIC using YeastOne (TREK Diagnostics Systems Inc., OH) and disk diffusion (NCCLS M44-A) using a standardized inoculum plated onto CHROMagar Candida as well as Mueller-Hinton agar to which 2% glucose and 0.5 μg/ml methylene blue dye was added (MH-GMB). The categorical interpretation derived from the MIC was used as the reference to which the disk diffusion results were compared. There were a total of 41 Candida albicans, 23 Candida glabrata, 20 Candida parapsilosis, 9 Candida tropicalis, and 1 each of Candida krusei and Candida lusitaniae tested. At 24 h there was full agreement among the methods for all C. albicans, C. tropicalis, C. lusitaniae, and C. krusei isolates. For the C. parapsilosis isolates at 24 h there was one very major discrepancy using the direct CHROMagar and one major error with the standardized MH-GMB. The majority of the errors were seen at 24 h with the C. glabrata isolates. Of the 23 C. glabrata isolates at 24 h by direct CHROMagar, there were 10 minor and 1 very major error; by MH-GMB there were 12 minor and 2 very major errors; and by standardized CHROMagar Candida there were 13 minor and 2 major errors. There were no very major errors with C. glabrata when all plates were read at 48 h. At 24 h by the direct and standardized CHROMagar the majority of C. glabrata isolates were more resistant, whereas by MH-GMB they were more susceptible than the reference MIC interpretation. In summary, subculturing yeast directly from blood cultures onto CHROMagar to which a fluconazole disk has been added may provide a presumptive identification at 24 h and, with the exception of C. glabrata, was able to predict the susceptibility to fluconazole with the majority of Candida isolates examined in this evaluation. PMID:15814992
Bruhn, D; Mikkelsen, T N; Obro, J; Willats, W G T; Ambus, P
2009-11-01
This study examines the effects of different irradiance types on aerobic methane (CH(4)) efflux rates from terrestrial plant material. Furthermore, the role of the enzyme pectin methyl esterase (PME) on CH(4) efflux potential was also examined. Different types of plant tissue and purified pectin were incubated in glass vials with different combinations of irradiation and/or temperature. Purified dry pectin was incubated in solution, and with or without PME. Before and after incubation, the concentration of CH(4) was measured with a gas chromatograph. Rates of CH(4) emission were found to depend exponentially on temperature and linearly on UV-B irradiance. UV-B had a greater stimulating effect than UV-A, while visible light had no effect on emission rates. PME was found to substantially reduce the potential for aerobic CH(4) emissions upon demethylation of pectin.
Wang, Qiming; Shalaev, Evgenyi
2018-04-01
In situ and non-invasive detection of solute crystallization during freeze-drying would facilitate cycle optimization and scale-up from the laboratory to commercial manufacturing scale. The objective of the study is to evaluate heat flux sensor (HFS) as a tool for monitoring solute crystallization and other first-order phase transitions (e.g., onset of freezing). HFS is a thin-film differential thermopile, which acts as a transducer to generate an electrical signal proportional to the total heat applied to its surface. In this study, HFS is used to detect both primary (ice formation) and secondary (also known as eutectic) solute + water crystallization during cooling and heating of solutions in a freeze-dryer. Binary water-solute mixtures with typical excipients concentrations (e.g., 0.9% of NaCl and 5% mannitol) and fill volumes (1 to 3 ml/vial) are studied. Secondary crystallization is detected by the HFS during cooling in all experiments with NaCl solutions, whereas timing of mannitol crystallization depends on the cooling conditions. In particular, mannitol crystallization takes place during cooling, if the cooling rate is lower than the critical value. On the other hand, if the cooling rate exceeds the critical cooling rate, mannitol crystallization during cooling is prevented, and crystallization occurs during subsequent warming or annealing. It is also observed that, while controlled ice nucleation allows initiation of the primary freezing event in different vials simultaneously, there is a noticeable vial-to-vial difference in the timing of secondary crystallization. The HFS could be a valuable process monitoring tool for non-invasive detection of various crystallization events during freeze-drying manufacturing.
Evaluation of a reflective coating for an organic scintillation detector
NASA Astrophysics Data System (ADS)
Tarancón, A.; Marin, E.; Tent, J.; Rauret, G.; Garcia, J. F.
2012-05-01
A reflective coating based on white paint, black paint and varnish has been evaluated to determine its reflective capabilities and its potential use in radioactivity detectors based on organic scintillators. Three different white paints, all of which were based on TiO2, were also tested to determine the one with the best performance and lowest radioactivity content. In a first experiment, we evaluated the capability of the reflective coating by measuring 90Sr/90Y with PSm in a polyethylene vial partially painted with EJ510 (Eljen Technology) reflective paint, black paint and varnish. In a second experiment, we compared the performance of the EJ510 to that of other white paints used for artistic purposes (Vallejo and Rembrandt). The results showed that, when a vial was only partially painted with the white paints (keeping a window free of paint to allow photons to exit), the efficiency and spectral distribution of the painted vial was similar to that of a non-painted vial. This behavior showed the efficiency of the reflective coatings. In terms of reflection capabilities, all of the tested paints were equivalent; however, the background was higher for the EJ510 paint. Analyses using high-resolution gamma spectroscopy indicated the presence of natural radionuclides (40K, 226Ra and 228Ra) in the EJ510. On the basis of the results (high reflection capabilities and the absence of radioactive impurities) and its lower cost, the Vallejo paint was selected as the white reflective paint. The final structure of the reflective coating was composed of five white paint layers, a black paint (to avoid external light entrance) and a layer of varnish (to protect the paints).
Kopp, Bettina; Crauste-Manciet, Sylvie; Guibert, Agnès; Mourier, Wilhelmine; Guerrault-Moro, Marie-Noelle; Ferrari, Sylvie; Jomier, Jean-Yves; Brossard, Denis; Schierl, Rudolf
2013-04-01
Environmental and biological monitoring of platinum containing drugs was implemented in two French hospital pharmacies using positive air pressure isolators and having similar working procedures when preparing antineoplastic drugs. Wipe sampling of surfaces, gloves, and vials was performed in the preparation room and in storage areas. All employees involved in the preparation of antineoplastic drugs were tested for urinary platinum on Monday before work and Friday after shift. Only traces of platinum were detected on surfaces in the preparation room outside the isolators (less than 1.61 pg cm(-2)). However, in one center, significant contamination was found in the storage area of the drug vials, which can most likely be linked to the rupture of a platinum vial and due to inefficient cleaning procedures. Surfaces inside the isolators were found to be contaminated (maximum: 198.4 pg cm(-2)). A higher level of contamination was detected in one pharmacy and could be explained by the lack of overgloving with regular changes during the preparation process. Nitrile gloves used during drug handling outside the isolator showed the highest platinum concentration (maximum: 5.86 ng per pair). With regards to platinum urine concentration, no significant difference was found between exposed and unexposed pharmacy personnel. Isolator technology combined with individual protective measures seems to be efficient to protect workers from occupational exposure to antineoplastic drugs, whereas specific individual protective procedures implemented were focussing on the risk of handling vials outside the isolator (e.g. high frequency of glove changing). Moreover, overgloving inside the isolator would contribute to substantially decrease inner surface contamination and should be recommended in order to limit the transfer of chemical contamination to the end products.
Multidose Botulinum Toxin A for Intralaryngeal Injection: A Cost Analysis.
Gilbert, Mark R; Young, VyVy N; Smith, Libby J; Rosen, Clark A
2018-01-04
Botulinum toxin A (BtxA) injection is the mainstay treatment for laryngeal dystonias. BtxA product labeling states that reconstituted toxin should be used within 4 hours on a single patient despite several studies that have demonstrated multidose BtxA to be safe and effective. Many insurance carriers mandate the use of an outside pharmacy which necessitates a single-use approach. This study compares the cost savings of multidose BtxA for laryngeal dystonia compared to single-use. This is a retrospective review and projected cost savings analysis. Records and billing information were reviewed for patients receiving BtxA for intralaryngeal injection at a single laryngology division in 2015. Inclusion criteria included CPT 64617 or J0585; exclusion criteria included CPT 64616. The price of BtxA 100 unit vial for calculation was $670. A total of 142 patients were seen for intralaryngeal BtxA injection resulting in 337 visits over 1 year. The average BtxA dose per visit was 2.86 units with an average of 3.06 procedure visits per year. The calculated cost of BtxA treatment using a single vial approach was found to be $2,050 per patient per year. If billed instead for $7/unit with 5 units wastage charge per visit, the yearly per patient charge is $168. Single vial-use of BtxA injection thus represents a 1,118% price increase versus multidose use. When estimated for yearly prevalence of spasmodic dysphonia, multidose BtxA use would save almost $100 million annually. Multidose botulinum toxin A application utilizing per unit billing is significantly less expensive than per single-use vial billing and would save the health-care system significant amount of money without any sacrifice in safety or effectiveness. Copyright © 2018. Published by Elsevier Inc.
The impact of primary packaging on the quality of parenteral products.
Solomun, Ljiljana; Ibric, Svetlana; Boltic, Zorana; Djuric, Zorica; Stupar, Biljana
2008-11-04
The unique approach in manufacturing of pharmaceutical dosage forms of active substances known to be unstable in aqueous solution is the introduction of lyophilization process. Nevertheless, these products must be reconstituted using the diluent from a separate container before application. The possible solution for this problem is the application of dual chamber vials comprising the freeze-dried product in a lower compartment of the vial and the solution for reconstitution in the upper chamber. The main issue in development of such product is the choice of contact packaging (rubber closures, glass vials and the container closure system as a whole). The most important parameter used for evaluation of the influence of contact material on product quality was the pH value. The results have shown that the type of vials (moulded or tubular glass) has no impact on pH shift of the solution for reconstitution (tested solution-TS), while significant differences in pH value of the TS were observed depending on the rubber closures formulation used (with some formulations, the pH shift during the test was 6.5-9.14). Benzyl alcohol assay during the tests remained unchanged. Integrity tests of the container closure system (CCS) have demonstrated the adequacy of the selected packaging system. The quality of the CCS of choice was confirmed in the course of stability studies, only parameters directly influenced by CCS being presented in this work: loss on drying and pH value. On the basis of these results, no changes in loss on drying were connected to CCS, and the pH value of the reconstituted solution remains unchanged in samples tested both ex-tempore and after in-use period of 48 h.
Preventive effect of cinnamon essential oil on lipid oxidation of vegetable oil
Keshvari, Mahtab; Asgary, Sedigheh; Jafarian-dehkordi, Abbas; Najafi, Somayeh; Ghoreyshi-Yazdi, Seyed Mojtaba
2013-01-01
BACKGROUND Lipid oxidation is the main deterioration process that occurs in vegetable oils. This process was effectively prevented by natural antioxidants. Cinnamomum zeylanicum (Cinnamon) is rich with antioxidants. The present study was conducted to evaluate the effect of cinnamon on malondialdehyde (MDA) rate production in two high consumption oils in Iranian market. METHODS Chemical composition of cinnamon essential oil was analyzed by gas chromatography-mass spectroscopy (GC-MS). 200 µl each oil, 50 µl tween 20, and 2 ml of 40 Mm AAPH solutions were mixed and the prepared solution was divided into four glass vials. Respectively, 50 µl of 500, 1000 and 2000 ppm of cinnamon essential oil were added to three glass vials separately and one of the glass vials was used as the control. All of the glass vials were incubated at 37° C water bath. Rate of MDA production was measured by thiobarbituric acid (TBA) test at the baseline and after the 0.5, 1, 2, 3 and 5 hours. RESULTS Compounds of cinnamon essential oil by GC-MS analysis such as cinnamaldehyde (96.8%), alpha-capaene (0.2%), alpha-murolene (0.11%), para-methoxycinnamaldehyde (0.6%) and delta-cadinen (0.4%) were found to be the major compounds. For both oils, maximum rate of MDA production was achieved in 5th hours of heating. Every three concentrations of cinnamon essential oil significantly decreased MDA production (P < 0.05) in comparison with the control. CONCLUSION Essential oil of cinnamon considerably inhibited MDA production in studied oils and can be used with fresh and heated oils for reduction of lipid peroxidation and adverse free radicals effects on body. PMID:24302936
Isolation of a virulent Newcastle disease virus from confiscated LaSota vaccine.
Pedersen, Janice C; Hines, Nichole L; Killian, Mary Lea; Predgen, Ann S; Schmitt, Beverly J
2013-06-01
Vials of Newcastle disease vaccine labeled as LaSota were confiscated by the Arizona Division of Customs and Border Protection officials. Two different avian type 1 paramyxoviruses were isolated from all three vials of vaccine submitted to the National Veterinary Services Laboratories. The LaSota strain of avian paramyxovirus type 1 virus was isolated from all three vials and analyzed by nucleotide sequence analysis. A virulent Newcastle disease virus was also present in all three vials, but in low concentration. The virulence of the Newcastle disease virus was characterized by the intracerebral chicken pathogenicity index chicken inoculation assay but could not be determined by nucleotide sequence analysis from the virus isolated from embryonating chicken eggs. The intracerebral chicken pathogenicity index value for the isolated Newcastle disease virus was 1.55. Strains of Newcastle disease virus with intracerebral pathogenicity indexes significantly above 1.0 have been found to selectively kill many types of cancer cells while not affecting normal nonneoplastic cells and are considered to be a viable option for cancer treatment in humans by alternative medical researchers; however, the treatment is not approved for use in the United States by the Food and Drug Administration. Customs and Border Protection officials have been notified of an increased risk of Newcastle disease virus entering the United States for use as a nonapproved cancer treatment. Illegal importation of Newcastle disease vaccine for vaccination of backyard poultry is also a threat. This case report emphasizes the importance of conducting chicken inoculation for complete virus pathotyping and demonstrates the need for stringent security procedures at U.S. borders to detect known livestock pathogens that may be smuggled in for use in animal agriculture and reasons unrelated to animal agriculture.
Effect of iron on inhibition of acid demineralisation of bovine dental enamel in vitro.
Buzalaf, Marília Afonso Rabelo; de Moraes Italiani, Flávia; Kato, Melissa Thiemi; Martinhon, Cleide Cristina Rodrigues; Magalhães, Ana Carolina
2006-10-01
Iron ions (Fe(2+)) have been shown to be cariostatic in many studies particularly by their ability to reduce bacterial metabolism. Nevertheless, the role of iron ions on dissolution of enamel is unexplored. The aim of the present study was therefore to investigate the protective effect of increasing concentrations (0-120mmol/L) of Fe(2+) on the dissolution of enamel. Enamel powder was subjected to acetic acid made with increasing concentrations with respect to FeSO(4)x7H(2)O. In order to determine the amount of enamel dissolved, the phosphate released in the medium was analysed spectrophotometrically using the Fiske-Subarrow method. Data were tested using Kruskall-Wall and Dunn's tests (p<0.05). The degree of protection was found to approach maximum at about 15mmol/L Fe(2+). Higher concentrations of Fe(2+) did not have an extra effect on inhibition of dissolution of enamel powder. In the next step, the protective effect of 15mmol/L Fe(2+) against mineral dissolution of the bovine enamel was evaluated using a simple abiotic model system. Enamel blocks were exposed to a sequence of seven plastic vials, each containing 1mL of 10mmol/L acetic acid. The acid in vial 4 was made 15mmol/L with respect to FeSO(4)x7H(2)O. The mineral dissolved during each challenge was thus determined by phosphate released as described above. Data were tested using two-way ANOVA (p<0.05). Lower demineralisation (around 45%) was found in vial 4 (with Fe) that continued stable until vial 7. Thus, our data suggest that Fe(2+) can be effective on inhibition of dissolution of enamel and that this effect may be durable.
Tritium-powered radiation sensor network
NASA Astrophysics Data System (ADS)
Litz, Marc S.; Russo, Johnny A.; Katsis, Dimos
2016-05-01
Isotope power supplies offer long-lived (100 years using 63Ni), low-power energy sources, enabling sensors or communications nodes for the lifetime of infrastructure. A tritium beta-source (12.5-year half-life) encapsulated in a phosphor-lined vial couples directly to a photovoltaic (PV) to generate a trickle current into an electrical load. An inexpensive design is described using commercial-of-the-shelf (COTS) components that generate 100 μWe for nextgeneration compact electronics/sensors. A matched radiation sensor has been built for long-duration missions utilizing microprocessor-controlled sleep modes, low-power electronic components, and a passive interrupt driven environmental wake-up. The low-power early-warning radiation detector network and isotope power source enables no-maintenance mission lifetimes.
Segura, Ferran; Pons, Immaculada; Sanfeliu, Isabel; Nogueras, María-Mercedes
2016-04-01
Rickettsia conorii and Rickettsia massiliae-Bar29 are related to Mediterranean spotted fever (MSF). They are intracellular microorganisms. The Shell-vial culture assay (SV) improved Rickettsia culture but it still has some limitations: blood usually contains low amount of microorganisms and the samples that contain the highest amount of them are non-sterile. The objectives of this study were to optimize SV culture conditions and monitoring methods and to establish antibiotic concentrations useful for non-sterile samples. 12 SVs were inoculated with each microorganism, incubated at different temperatures and monitored by classical methods and real-time PCR. R. conorii was detected by all methods at all temperatures since 7th day of incubation. R. massiliae-Bar29 was firstly observed at 28°C. Real-time PCR allowed to detected it 2-7 days earlier (depend on temperature) than classical methods. Antibiotics concentration needed for the isolation of these Rickettsia species from non-sterile samples was determined inoculating SV with R. conorii, R. massiliae-Bar29, biopsy or tick, incubating them with different dilutions of antibiotics and monitoring them weekly. To sum up, if a MSF diagnosis is suspected, SV should be incubated at both 28°C and 32°C for 1-3 weeks and monitored by a sensitive real-time PCR. If the sample is non-sterile the panel of antibiotics tested can be added. Copyright © 2016 Elsevier GmbH. All rights reserved.
Drug wastage contributes significantly to the cost of routine anesthesia care.
Weinger, M B
2001-11-01
To complement previous studies that employed indirect methods of measuring anesthesia drug waste. Prospective, blinded observational study. Operating rooms of a single university hospital. Anesthesia providers practicing in this setting who were completely unaware of the conduct of the study. All opened and unused or unusable intravenous (IV) anesthesia drugs left over at the end of each workday were collected over a randomly selected typical 2-week period. 166 weekday cases were performed. Thirty different drugs were represented in the 157 syringes and 139 ampoules collected. Opioid waste as well as opened vials that became outdated were counted in the tally. Based on actual hospital drug acquisition costs, $1,802 of drugs were wasted during this 2-week period ($300/OR), amounting to an average cost per case of $10.86. On a cost basis, six drugs accounted for three quarters of the total wastage: phenylephrine (20.8%), propofol (14.5%), vecuronium (12.2%), midazolam (11.4%), labetalol (9.1%), and ephedrine (8.6%). Because incompletely used syringes or vials that were discarded in the trash were not measured in this analysis, the results may underestimate the total cost of drug wastage at this institution by up to 40%. The results of this study are similar to those of previous studies that employed electronic record keeping techniques to calculate drug waste. Intravenous drugs that are prepared but unused may be a significant cost of intraoperative anesthesia care. Methods to reduce the amount of drug wasted are proposed.
Chippaux, J-P; Baldé, M C; Sessinou, É; Yéro Boiro, M; Massougbodji, A
2015-01-01
The authors evaluated the safety and efficacy of Inoserp(®) Pan Africa, a new polyvalent antivenom composed of highly purified and lyophilized fragments of F(ab')2 immunoglobulins, recently registered in Benin and Guinea. We treated 100 patients in northern Benin (Atacora) and 109 in Maritime Guinea (Kindia) with confirmed envenomation. Treatment consisted of intravenous administration of 1 vial for uncomplicated envenomation, and 2 vials for hemorrhagic or neurotoxic envenomation. The dose was repeated when bleeding or signs of neurotoxicity persisted or appeared. In Atacora, on arrival at the hospital, 90% of patients had incoagulable blood, and 50% were bleeding. The resolution of these bleeding disorders was obtained in less than 3 hours for 50% of the patients and in less than 24 hours for 98%. Four patients died. In Kindia, 96 patients (88%) presented viper bites with pain + edema and 13 (12 %) others showed elapid (ptosis, dyspnea) envenomation. One patient bitten by a member of the Elapidae family, died despite early treatment. In Benin, protocol deviations for 60% of patients led to significant underdosing of the antivenom; the proportion was much lower (2%) in Guinea. Signs of intolerance after Inoserp(®) Pan Africa administration were reported in 8% of patients. All these symptoms were mild and disappeared rapidly after an antihistamine or corticosteroid treatment. Treatment using intravenous Inoserp(®) Pan Africa appeared to be well tolerated and effective against snakebite envenomation in both epidemiological settings.
Jakovljev, Aleksandra; Bergh, Kåre
2015-11-06
Bloodstream infections represent serious conditions carrying a high mortality and morbidity rate. Rapid identification of microorganisms and prompt institution of adequate antimicrobial therapy is of utmost importance for a successful outcome. Aiming at the development of a rapid, simplified and efficient protocol, we developed and compared two in-house preparatory methods for the direct identification of bacteria from positive blood culture flasks (BD BACTEC FX system) by using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI TOF MS). Both methods employed saponin and distilled water for erythrocyte lysis. In method A the cellular pellet was overlaid with formic acid on the MALDI TOF target plate for protein extraction, whereas in method B the pellet was exposed to formic acid followed by acetonitrile prior to placing on the target plate. Best results were obtained by method A. Direct identification was achieved for 81.9 % and 65.8 % (50.3 % and 26.2 % with scores >2.0) of organisms by method A and method B, respectively. Overall concordance with final identification was 100 % to genus and 97.9 % to species level. By applying a lower cut-off score value, the levels of identification obtained by method A and method B increased to 89.3 % and 77.8 % of organisms (81.9 % and 65.8 % identified with scores >1.7), respectively. Using the lowered score criteria, concordance with final results was obtained for 99.3 % of genus and 96.6 % of species identifications. The reliability of results, rapid performance (approximately 25 min) and applicability of in-house method A have contributed to implementation of this robust and cost-effective method in our laboratory.
NASA Astrophysics Data System (ADS)
Ali, Hassan Refat H.; Edwards, Howell G. M.; Scowen, Ian J.
2009-05-01
For the manufacture of dosage forms all ingredients must be reliably identified. In this paper, the suitability of FT-NIR spectroscopy to identify potassium sorbate, sodium starch glycollate, calcium ascorbate, calcium carbonate, candelilla wax, maltosextrin, monohydrated and anhydrous lactose inside USP vials was investigated. Differentiation between the anhydrous and monohydrated forms of lactose was found to be possible by studying the regions of the near-infrared spectrum corresponding to the combination and first overtone stretching frequencies of water. The results show unequivocally the potential of FT-NIR spectroscopy for rapid, in situ and non-destructive identification of pharmaceutical excipients.
NASA Astrophysics Data System (ADS)
Falcoff, Daniel E.; Canali, Luis R.
1999-08-01
This work present one method aimed to individualization and recognition of vial signs in route and city. It is based fundamentally on the identification by means of color and form of the vial sing, located in the border of the route or street in city, and then recognition. To do so the obtained RGB image is processed, carrying out diverse filtrates in the sequence of input image, or intensifying the colors of the same ones otherwise, recognizing their silhouette and then segmenting the sign and comparing the symbology of them with the previously stored and classified database.
Gravimetric measurement of momentary drying rate of spray freeze-dried powders in vials.
Gieseler, Henning; Lee, Geoffrey
2009-09-01
The profile of drying rate versus primary drying time for a spray freeze-dried trehalose aqueous solution is much different from that determined for regular freeze-drying. Drying rate declines very rapidly, attributed to rate-limiting heat transfer through the packed bed of frozen microparticles contained in a vial. The inter-particulate spaces appear to be the cause of this rate limitation. Use of either liquid nitrogen or liquid propane as a cryogenic produced strong differences in both SFD particle morphology and drying rate using trehalose, sucrose, or mannitol. The lack of any evident correlation supports the argument that the inter-particulate voids determine drying behavior.
Microbiological challenge of four protective devices for the reconstitution of cytotoxic agents.
De Prijck, K; D'Haese, E; Vandenbroucke, J; Coucke, W; Robays, H; Nelis, H J
2008-12-01
To evaluate the susceptibility to microbial contamination that occurs during simulated handling of protective devices for the preparation of cytotoxic drug solutions. Four devices, i.e. Chemoprotect spike, Clave connector, PhaSeal and Securmix were challenged with low and high inocula of micro-organisms. The cells, transferred to the connected vials during repeated manipulations of the devices were counted by means of solid-phase cytometry. Of the four devices, PhaSeal afforded the lowest transfer of micro-organisms. Secondly, the efficiency of procedures for the disinfection of an artificially contaminated rubber stopper was compared prior to connection of the vial to the PhaSeal device. Spraying or swabbing alone was inadequate, as opposed to a combination of spraying [0.5% or 2.0% (w/v) chlorhexidine in isopropanol] and swabbing [70% (v/v) isopropanol]. Although Phaseal afforded the lowest transfer of micro-organisms, adequate disinfection of the vial prior to connection remains required. Unlike aspects of operator protection, which are well documented, the microbiological safety of protective devices for the preparation of cytotoxic drugs has not been addressed in the literature. This study estimates the susceptibility to microbial contamination during handling of four commonly used devices.
Farley, Christopher; Burks, Geoffry; Siegert, Thomas; Juers, Douglas H
2014-08-01
In macromolecular cryocrystallography unit-cell parameters can have low reproducibility, limiting the effectiveness of combining data sets from multiple crystals and inhibiting the development of defined repeatable cooling protocols. Here, potential sources of unit-cell variation are investigated and crystal dehydration during loop-mounting is found to be an important factor. The amount of water lost by the unit cell depends on the crystal size, the loop size, the ambient relative humidity and the transfer distance to the cooling medium. To limit water loss during crystal mounting, a threefold strategy has been implemented. Firstly, crystal manipulations are performed in a humid environment similar to the humidity of the crystal-growth or soaking solution. Secondly, the looped crystal is transferred to a vial containing a small amount of the crystal soaking solution. Upon loop transfer, the vial is sealed, which allows transport of the crystal at its equilibrated humidity. Thirdly, the crystal loop is directly mounted from the vial into the cold gas stream. This strategy minimizes the exposure of the crystal to relatively low humidity ambient air, improves the reproducibility of low-temperature unit-cell parameters and offers some new approaches to crystal handling and cryoprotection.
Farley, Christopher; Burks, Geoffry; Siegert, Thomas; Juers, Douglas H.
2014-01-01
In macromolecular cryocrystallography unit-cell parameters can have low reproducibility, limiting the effectiveness of combining data sets from multiple crystals and inhibiting the development of defined repeatable cooling protocols. Here, potential sources of unit-cell variation are investigated and crystal dehydration during loop-mounting is found to be an important factor. The amount of water lost by the unit cell depends on the crystal size, the loop size, the ambient relative humidity and the transfer distance to the cooling medium. To limit water loss during crystal mounting, a threefold strategy has been implemented. Firstly, crystal manipulations are performed in a humid environment similar to the humidity of the crystal-growth or soaking solution. Secondly, the looped crystal is transferred to a vial containing a small amount of the crystal soaking solution. Upon loop transfer, the vial is sealed, which allows transport of the crystal at its equilibrated humidity. Thirdly, the crystal loop is directly mounted from the vial into the cold gas stream. This strategy minimizes the exposure of the crystal to relatively low humidity ambient air, improves the reproducibility of low-temperature unit-cell parameters and offers some new approaches to crystal handling and cryoprotection. PMID:25084331
NASA Astrophysics Data System (ADS)
Hamid, Puteri Nor Khatijah Abd; Yusof, Mohd Fahmi Mohd; Aziz Tajuddin, Abd; Hashim, Rokiah; Zainon, Rafidah
2018-01-01
The aim of this study was to design and evaluate of corn starch-bonded Rhizophora spp. particleboards as phantom for SPECT/CT imaging. The phantom was designed according to the Jaszczak phantom commonly used in SPECT imaging with dimension of 22 cm diameter and 18 cm length. Six inserts with different diameter were made for insertion of vials filled with 1.6 µCi/ml of 99mTc unsealed source. The particleboard phantom was scanned using SPECT/CT imaging protocol. The contrast of each vial for particleboards phantom were calculated based on the ratio of counts in radionuclide volume and phantom background and compared to Perspex® and water phantom. The results showed that contrast values for each vial in particleboard phantomis near to 1.0 and in good agreement with Perspex® and water phantoms as common phantom materials for SPECT/CT. The paired sample t-test result showed no significant difference of contrast values between images in particleboard phantoms and that in water. The overall results showed the potential of corn starch-bonded Rhizophora spp. as phantom for quality control and dosimetry works in SPECT/CT imaging.
Acoustically active lipospheres containing paclitaxel: a new therapeutic ultrasound contrast agent.
Unger, E C; McCreery, T P; Sweitzer, R H; Caldwell, V E; Wu, Y
1998-12-01
Paclitaxel-carrying lipospheres (MRX-552) were developed and evaluated as a new ultrasound contrast agent for chemotherapeutic drug delivery. Paclitaxel was suspended in soybean oil and added to an aqueous suspension of phospholipids in vials. The headspace of the vials was replaced with perfluorobutane gas; the vials were sealed, and they were agitated at 4200 rpm on a shaking device. The resulting lipospheres containing paclitaxel were studied for concentration, size, acute toxicity in mice, and acoustic activity and drug release with ultrasound. Lipospheres containing sudan black dye were produced to demonstrate the acoustically active liposphere (AAL)-ultrasound release concept. Acoustically active lipospheres containing paclitaxel had a mean particle count of approximately 1 x 10(9) particles per mL and a mean size of 2.9 microns. Acute toxicity studies in mice showed a 10-fold reduction in toxicity for paclitaxel in AALs compared with free paclitaxel. The AALs reflected ultrasound as a contrast agent. Increasing amounts of ultrasound energy selectively ruptured the AALs and released the paclitaxel. Acoustically active lipospheres represent a new class of acoustically active drug delivery vehicles. Future studies will assess efficacy of AALs for ultrasound-mediated drug delivery.
Gava, A; Bertossi, L; Ferrarese, F; Coghetto, F; Marazzato, G; Andrulli, A D; Zorat, P L
1998-03-01
Radiotherapy patients are at risk of developing leukopenia, which risk depends on the irradiated volume, the rate of irradiated bone marrow and the radiation dose. Radiogenic leukopenia may cause radiotherapy drop-out, with consequent effects, on local tumor control and clinical outcome. The introduction of granulocyte growth factors, such as filgrastim, has permitted to accelerate normal neutrophil count recovery in irradiation-related neutropenia both in vitro and animal models; clinical experience in humans is still lacking, relative to both indications and scheduling. In the Oncologic Radiotherapy Department of Treviso Hospital, 31 patients irradiated for Hodgkin disease, rectal cancer and other malignancies, who presented leukopenia requiring treatment discontinuation, were given filgrastim to assess its actual effect in avoiding further drop-outs and to compare two administration schedules (2 or 3 vials, 30 MIU, weekly). Filgrastim treatment was continued throughout the radiotherapy cycles, for 1 to 5 weeks. Eighteen patients had received previous chemotherapy and 11 were undergoing concurrent 5-fluorouracil chemotherapy-irradiation. A mean 203% increase in leukocyte count was observed (136% in the patients treated with 2 vials/week and 274% in those receiving 3 vials/week); this increase was more apparent in women that in men (256% versus 91%) and slightly higher in patients 50 years old and with target volumes < 5000 ml. Filgrastin treatment was well tolerated by all patients, with no discontinuations due to adverse effects; 9 patients (29%) reported skeletal pain, which was marked in 2 of them only. Eighty percent of patients completed all the radiotherapy cycles with no discontinuation, while 6 patients dropped out because leukopenia persisted. Biweekly filgrastim administration was effective to prevent unscheduled radiotherapy discontinuation in 75% of patients and triweekly administration was effective in 86% of patients. In our experience, filgrastim administration was well tolerated and effective in decreasing the irradiation drop-outs caused by treatment-related leukopenia. Since this drug is rather expensive, we decided to use routinely the lower dosage of biweekly administration (with one vial given on Friday and Saturday, to permit neutrophil recovery during the day off) and to reserve the higher dosage (3 vials a week) to the patients with large body areas, big target volumes and persistent leukopenia during previous chemotherapy.
The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy
NASA Astrophysics Data System (ADS)
Gear, J. I.; Flux, G. D.; Charles-Edwards, E.; Partridge, M.; Cook, G.; Ott, R. J.
2006-07-01
There is a lack of standardized methodology to perform dose calculations for targeted radionuclide therapy and at present no method exists to objectively evaluate the various approaches employed. The aim of the work described here was to investigate the practicality and accuracy of calibrating polymer gel dosimeters such that dose measurements resulting from complex activity distributions can be verified. Twelve vials of the polymer gel dosimeter, 'MAGIC', were uniformly mixed with varying concentrations of P-32 such that absorbed doses ranged from 0 to 30 Gy after a period of 360 h before being imaged on a magnetic resonance scanner. In addition, nine vials were prepared and irradiated using an external 6 MV x-ray beam. Magnetic resonance transverse relaxation time, T2, maps were obtained using a multi-echo spin echo sequence and converted to R2 maps (where T2 = 1/R2). Absorbed doses for P-32 irradiated gel were calculated according to the medical internal radiation dose schema using EGSnrc Monte Carlo simulations. Here the energy deposited in cylinders representing the irradiated vials was scored. A relationship between dose and R2 was determined. Effects from oxygen contamination were present in the internally irradiated vials. An increase in O2 sensitivity over those gels irradiated externally was thought to be a result of the longer irradiation period. However, below the region of contamination dose response appeared homogenous. Due do a drop-off of dose at the periphery of the internally irradiated vials, magnetic resonance ringing artefacts were observed. The ringing did not greatly affect the accuracy of calibration, which was comparable for both methods. The largest errors in calculated dose originated from the initial activity measurements, and were approximately 10%. Measured R2 values ranged from 5-35 s-1 with an average standard deviation of 1%. A clear relationship between R2 and dose was observed, with up to 40% increased sensitivity for internally irradiated gels. Curve fits to the calibration data followed a single exponential function. The correlation coefficients for internally and externally irradiated gels were 0.991 and 0.985, respectively. With the ability to accurately calibrate internally dosed polymer gels, this technology shows promise as a means to evaluate dosimetry methods, particularly in cases of non-uniform uptake of a radionuclide.
TU-H-CAMPUS-IeP2-01: Quantitative Evaluation of PROPELLER DWI Using QIBA Diffusion Phantom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yung, J; Ai, H; Liu, H
Purpose: The purpose of this study is to determine the quantitative variability of apparent diffusion coefficient (ADC) values when varying imaging parameters in a diffusion-weighted (DW) fast spin echo (FSE) sequence with Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER) k-space trajectory. Methods: Using a 3T MRI scanner, a NIST traceable, quantitative magnetic resonance imaging (MRI) diffusion phantom (High Precision Devices, Inc, Boulder, Colorado) consisting of 13 vials filled with various concentrations of polymer polyvinylpyrrolidone (PVP) in aqueous solution was imaged with a standard Quantitative Imaging Biomarkers Alliance (QIBA) DWI spin echo, echo planar imaging (SE EPI) acquisition. Themore » same phantom was then imaged with a DWI PROPELLER sequence at varying echo train lengths (ETL) of 8, 20, and 32, as well as b-values of 400, 900, and 2000. QIBA DWI phantom analysis software was used to generate ADC maps and create region of interests (ROIs) for quantitative measurements of each vial. Mean and standard deviations of the ROIs were compared. Results: The SE EPI sequence generated ADC values that showed very good agreement with the known ADC values of the phantom (r2 = 0.9995, slope = 1.0061). The ADC values measured from the PROPELLER sequences were inflated, but were highly correlated with an r2 range from 0.8754 to 0.9880. The PROPELLER sequence with an ETL=20 and b-value of 0 and 2000 showed the closest agreement (r2 = 0.9034, slope = 0.9880). Conclusion: The DW PROPELLER sequence is promising for quantitative evaluation of ADC values. A drawback of the PROPELLER sequence is the longer acquisition time. The 180° refocusing pulses may also cause the observed increase in ADC values compared to the standard SE EPI DW sequence. However, the FSE sequence offers an advantage with in-plane motion and geometric distortion which will be investigated in future studies.« less
Disposing of Excess Vaccines After the Withdrawal of Oral Polio Vaccine
Ramirez Gonzalez, Alejandro; Dolan, Samantha B.; Garon, Julie; Veira, Chantal Laroche; Hampton, Lee M.; Chang Blanc, Diana; Patel, Manish M.
2017-01-01
Abstract Until recently, waste management for national immunization programs was limited to sharps waste, empty vaccine vials, or vaccines that had expired or were no longer usable. However, because wild-type 2 poliovirus has been eradicated, the World Health Organization’s (WHO’s) Strategic Advisory Group of Experts on Immunization deemed that all countries must simultaneously cease use of the type 2 oral polio vaccine and recommended that all countries and territories using oral polio vaccine (OPV) “switch” from trivalent OPV (tOPV; types 1, 2, and 3 polioviruses) to bivalent OPV (bOPV; types 1 and 3 polioviruses) during a 2-week period in April 2016. Use of tOPV after the switch would risk outbreaks of paralysis related to type 2–circulating vaccine-derived poliovirus (cVDPV2). To minimize risk of vaccine-derived polio countries using OPV were asked to dispose of all usable, unexpired tOPV after the switch to bOPV. In this paper, we review the rationale for tOPV disposal and describe the global guidelines provided to countries for the safe and appropriate disposal of tOPV. These guidelines gave countries flexibility in implementing this important task within the confines of their national regulations, capacities, and resources. Steps for appropriate disposal of tOPV included removal of all tOPV vials from the cold chain, placement in appropriate bags or containers, and disposal using a recommended approach (ie, autoclaving, boiling, chemical inactivation, incineration, or encapsulation) followed by burial or transportation to a designated waste facility. This experience with disposal of tOPV highlights the adaptability of national immunization programs to new procedures, and identifies gaps in waste management policies and strategies with regard to disposal of unused vaccines. The experience also provides a framework for future policies and for developing programmatic guidance for the ultimate disposal of all OPV after the eradication of polio. PMID:28838168
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soliman, A; Hashemi, M; Safigholi, H
Purpose: To explore the feasibility of extracting the relative density from quantitative MRI measurements as well as estimate a correlation between the extracted measures and CT Hounsfield units. Methods: MRI has the ability to separate water and fat signals, producing two separate images for each component. By performing appropriate corrections on the separated images, quantitative measurement of water and fat mass density can be estimated. This work aims to test this hypothesis on 1.5T.Peanut oil was used as fat-representative, while agar as water-representative. Gadolinium Chloride III and Sodium Chloride were added to the agar solution to adjust the relaxation timesmore » and the medium conductivity, respectively. Peanut oil was added to the agar solution with different percentages: 0%, 3%, 5%, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90% and 100%. The phantom was scanned on 1.5T GE Optima 450W with the body coil using a multigradient echo sequences. Water/fat separation were performed while correcting for main field (B0) inhomogeneity and T{sub 2}* relaxation time. B1+ inhomogeneities were ignored. The phantom was subsequently scanned on a Philips Brilliance CT Big Bore. MR-corrected fat signal from all vials were normalized to 100% fat signal. CT Hounsfield values were then compared to those obtained from the normalized MR-corrected fat values as well as to the phantom for validation. Results: Good agreement were found between CT HU and the MR-extracted fat values (R{sup 2} = 0.98). CT HU also showed excellent agreement with the prepared fat fractions (R{sup 2}=0.99). Vials with 70%, 80%, and 90% fat percentages showed inhomogeneous distributions, however their results were included for completion. Conclusion: Quantitative MRI water/fat imaging can be potentially used to extract the relative tissue density. Further in-vivo validation are required.« less
Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N
2005-01-24
In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures.
Inactivation of Mycobacterium paratuberculosis in cows' milk at pasteurization temperatures.
Grant, I R; Ball, H J; Neill, S D; Rowe, M T
1996-01-01
The thermal inactivation of 11 strains of Mycobacterium paratuberculosis at pasteurization temperatures was investigated. Cows' milk inoculated with M. paratuberculosis at two levels (10(7) and 10(4) CFU/ml) was pasteurized in the laboratory by (i) a standard holder method (63.5 degrees C for 30 min) and (ii) a high-temperature, short-time (HTST) method (71.7 degrees C for 15 s). Additional heating times of 5, 10, 15, 20, and 40 min at 63.5 degrees C were included to enable the construction of a thermal death curve for the organism. Viability after pasteurization was assessed by culture on Herrold's egg yolk medium containing mycobactin J (HEYM) and in BACTEC Middlebrook 12B radiometric medium supplemented with mycobactin J and sterile egg yolk emulsion. Confirmation of acid-fast survivors of pasteurization as viable M. paratuberculosis cells was achieved by subculture on HEYM to indicate viability coupled with PCR using M. paratuberculosis-specific 1S900 primers. When milk was initially inoculated with 10(6) to 10(7) CFU of M. paratuberculosis per ml, M. paratuberculosis cells were isolated from 27 of 28 (96%) and 29 of 34 (85%) pasteurized milk samples heat treated by the holder and HTST methods, respectively. Correspondingly, when 10(3) to 10(4) CFU of M. paratuberculosis per ml of milk were present before heat treatment, M. paratuberculosis cells were isolated from 14 of 28 (50%) and 19 of 33 (58%) pasteurized milk samples heat treated by the holder and HTST methods, respectively. The thermal death curve for M. paratuberculosis was concave in shape, exhibiting a rapid initial death rate followed by significant "tailing." Results indicate that when large numbers of M. paratuberculosis cells are present in milk, the organism may not be completely inactivated by heat treatments simulating holder and HTST pasteurization under laboratory conditions. PMID:8593064
Whittington, Richard J.; Marsh, Ian B.; Saunders, Vanessa; Grant, Irene R.; Juste, Ramon; Sevilla, Iker A.; Manning, Elizabeth J. B.; Whitlock, Robert H.
2011-01-01
Mycobacterium avium subsp. paratuberculosis causes paratuberculosis (Johne's disease) in ruminants in most countries. Historical data suggest substantial differences in culturability of M. avium subsp. paratuberculosis isolates from small ruminants and cattle; however, a systematic comparison of culture media and isolates from different countries and hosts has not been undertaken. Here, 35 field isolates from the United States, Spain, Northern Ireland, and Australia were propagated in Bactec 12B medium and Middlebrook 7H10 agar, genomically characterized, and subcultured to Lowenstein-Jensen (LJ), Herrold's egg yolk (HEY), modified Middlebrook 7H10, Middlebrook 7H11, and Watson-Reid (WR) agars, all with and without mycobactin J and some with sodium pyruvate. Fourteen genotypes of M. avium subsp. paratuberculosis were represented as determined by BstEII IS900 and IS1311 restriction fragment length polymorphism analysis. There was no correlation between genotype and overall culturability, although most S strains tended to grow poorly on HEY agar. Pyruvate was inhibitory to some isolates. All strains grew on modified Middlebrook 7H10 agar but more slowly and less prolifically on LJ agar. Mycobactin J was required for growth on all media except 7H11 agar, but growth was improved by the addition of mycobactin J to 7H11 agar. WR agar supported the growth of few isolates. The differences in growth of M. avium subsp. paratuberculosis that have historically been reported in diverse settings have been strongly influenced by the type of culture medium used. When an optimal culture medium, such as modified Middlebrook 7H10 agar, is used, very little difference between the growth phenotypes of diverse strains of M. avium subsp. paratuberculosis was observed. This optimal medium is recommended to remove bias in the isolation and cultivation of M. avium subsp. paratuberculosis. PMID:21430104
Field-test of a date-rape drug detection device.
Quest, Dale W; Horsley, Joanne
2007-01-01
Drink Safe Technology Version 1.2 is an inexpensive color-change reagent test marketed internationally for use by consumers in settings such as a night club to detect potentially incapacitating concentrations of gamma-hydroxybutyric acid (GHB) and ketamine in beverages. The objective of this study was to compare product performance in the laboratory and performance in the hands of consumers in the field. Product performance in the laboratory adhered to the protocol defined by the manufacturer. Product performance in the hands of consumers in field settings allowed browsing participants to pipette an aliquot of their own drinks into randomly coded vials containing authentic drugs, or pure water, so as to yield the same concentrations of GHB or ketamine specified in the manufacturer-defined protocol, or blanks. Consumers were to proceed according to the directions printed on the product, and to record their results on a card with a code corresponding with the vial to which they had added an aliquot of their beverage. Diagnostic performance was calculated using two-way analysis. In the laboratory, Drink Safe Technology Version 1.2 reliably detected GHB and ketamine at concentrations specified by the manufacturer's protocol. The reactive color change denoting a positive test for GHB was rapid, but a positive test for ketamine required substantially more time to resolve. Nonetheless, test accuracy following the manufacturer's protocol in the laboratory was 100%. In the field, based on 101 paired-test results recorded by consumers, the test efficiency was 65.1%, sensitivity 50%, and specificity 91.6%. The product performed much better in the laboratory than it did in the hand of consumers in the field. There seems to be considerable potential for consumers to misinterpret a test result. The potential for consumers to record a false-negative test result for a spiked drink is cause for concern.
Liu, Lu; Ammar, David A.; Ross, Lindsey A.; Mandava, Naresh; Kahook, Malik Y.
2011-01-01
Purpose. To quantify levels of subvisible particles and protein aggregates in repackaged bevacizumab obtained from compounding pharmacies, as well as in samples of bevacizumab and ranibizumab tested in controlled laboratory experiments. Methods. Repackaged bevacizumab was purchased from four external compounding pharmacies. For controlled laboratory studies, bevacizumab and placebo were drawn into plastic syringes and incubated at −20°C, 4°C, and room temperature (with and without exposure to light) for 12 weeks. In addition, mechanical shock occurring during shipping was mimicked with syringes containing bevacizumab. Particle counts and size distributions were quantified by particle characterization technology. Levels of monomer and soluble aggregates of bevacizumab were determined with size-exclusion high-performance liquid chromatography (SE-HPLC). Results. Repackaged bevacizumab from the compounding pharmacies had a wide range of particle counts (89,006 ± 56,406 to 602,062 ± 18,349/mL). Bevacizumab sampled directly from the original glass vial had particle counts of 63,839 ± 349/mL. There was up to a 10% monomer loss in the repackaged bevacizumab. Laboratory samples of repackaged bevacizumab and placebo had initial particle counts, respectively, of 283,675 ± 60,494/mL and 492,314 ± 389,361/mL. Freeze-thawing of both bevacizumab and placebo samples led to >1.2 million particles/mL. In all repackaged samples, most of the particles were due to silicone oil. SE-HPLC showed no significant differences for repackaged samples incubated in the laboratory under various conditions, compared with bevacizumab directly from vial. However, repeated freeze-thawing caused a more than 10% monomer loss. Conclusions. Bevacizumab repackaged in plastic syringes could contain protein aggregates and is contaminated by silicone oil microdroplets. Freeze-thawing or other mishandling can further increase levels of particle contaminants. PMID:21051703
Künzle, N; Petignat, C; Francioli, P; Vogel, G; Seydoux, C; Corpataux, J M; Sahli, R; Meylan, P R
2000-09-01
Cytomegalovirus (CMV) remains a major cause of morbidity in solid organ transplant patients. In order to reduce CMV morbidity, we designed a program of routine virological monitoring that included throat and urine CMV shell vial culture, along with peripheral blood leukocyte (PBL) shell vial quantitative culture for 12 weeks post-transplantation, as well as 8 weeks after treatment for acute rejection. The program also included preemptive ganciclovir treatment for those patients with the highest risk of developing CMV disease, i.e., with either high-level viremia (>10 infectious units [IU]/106 PBL) or low-level viremia (<10 IU/106 PBL) and either D+/R- CMV serostatus or treatment for graft rejection. During 1995-96, 90 solid organ transplant recipients (39 kidneys, 28 livers, and 23 hearts) were followed up. A total of 60 CMV infection episodes occurred in 45 patients. Seventeen episodes were symptomatic. Of 26 episodes managed according to the program, only 4 presented with CMV disease and none died. No patient treated preemptively for asymptomatic infection developed disease. In contrast, among 21 episodes managed in non-compliance with the program (i.e., the monitoring was not performed or preemptive treatment was not initiated despite a high risk of developing CMV disease), 12 episodes turned into symptomatic infection (P=0.0048 compared to patients treated preemptively), and 2 deaths possibly related to CMV were recorded. This difference could not be explained by an increased proportion of D+/R- patients or an increased incidence of rejection among patients with episodes treated in non-compliance with the program. Our data identify compliance with guidelines as an important factor in effectively reducing CMV morbidity through preemptive treatment, and suggest that the complexity of the preemptive approach may represent an important obstacle to the successful prevention of CMV morbidity by this approach in the regular healthcare setting.
NASA Technical Reports Server (NTRS)
Kelbaugh, B. N.; Picciolo, G. L.; Chappelle, E. W.; Colburn, M. E. (Inventor)
1973-01-01
An automated apparatus is reported for sequentially assaying urine samples for the presence of bacterial adenosine triphosphate (ATP) that comprises a rotary table which carries a plurality of sample containing vials and automatically dispenses fluid reagents into the vials preparatory to injecting a light producing luciferase-luciferin mixture into the samples. The device automatically measures the light produced in each urine sample by a bioluminescence reaction of the free bacterial adenosine triphosphate with the luciferase-luciferin mixture. The light measured is proportional to the concentration of bacterial adenosine triphosphate which, in turn, is proportional to the number of bacteria present in the respective urine sample.
Study of methods for the improvement of bacterial transport media
NASA Technical Reports Server (NTRS)
Gardner, R. L.; Beakley, J. W.
1973-01-01
A series of 500 transport media recipes was tested for ability to hold pure cultures of Streptococcus equisimilus, Corynebacterium equi, Neisseria perflava, and Haemophilus parainfluenzae for 21 days. Stuart Medium Base with 0.4% agar was used as the control medium for this and the other experiments in the investigation. At the end of the holding period inoculated transport media were quantitatively assayed, and the control media were assayed immediately after inoculation. Three vials of each medium were inoculated with an organism, and each vial's medium was diluted and spread on duplicate plates. Assay media for this experiment included Brain Heart Infusion,(BHIA) Tryptic Soy Agar, and BHIA with 1% Isovitalex enrichment.
Experimental determination of the key heat transfer mechanisms in pharmaceutical freeze-drying.
Ganguly, Arnab; Nail, Steven L; Alexeenko, Alina
2013-05-01
The study is aimed at quantifying the relative contribution of key heat transfer modes in lyophilization. Measurements of vial heat transfer rates in a laboratory-scale freeze-dryer were performed using pure water, which was partially sublimed under various conditions. The separation distance between the shelf and the vial was systematically varied, and sublimation rates were determined gravimetrically. The heat transfer rates were observed to be independent of separation distance between the vial and the shelf and linearly dependent on pressure in the free molecular flow limit, realized at low pressures (<50 mTorr). However, under higher pressures (>120 mTorr), heat transfer rates were independent of pressure and inversely proportional to separation distance. Previous heat transfer studies in conventional freeze-drying cycles have attributed a dominant portion of the total heat transfer to radiation, the rest to conduction, whereas convection has been found to be insignificant. Although the measurements reported here confirm the significance of the radiative and gas conduction components, the convective component has been found to be comparable to the gas conduction contribution at pressures greater than 100 mTorr. The current investigation supports the conclusion that the convective component of the heat transfer cannot be ignored in typical laboratory-scale freeze-drying conditions. Copyright © 2013 Wiley Periodicals, Inc.
Morrical, Bradley D; Goverde, Marcel; Grausse, Jean; Gerwig, Tanja; Vorgrimler, Lothar; Morgen, Rachel; Büttiker, Jean-Pierre
2007-01-01
A direct test method using helium leak detection was developed to determine microbial ingress in parenteral vial/rubber closure systems. The purpose of this study was to establish a direct correlation between the helium leak rate and the presence of ingress when vials were submersed under pressure in a broth of bacteria. Results were obtained for two different types of leaks: microholes that have been laser-drilled into thin metal plates, and thin copper wire that was placed between the rubber closure and the glass vial's sealing surface. The results from the microholes showed that the helium leak rate was a function of the square of the hole diameter and fit well with theoretical calculations. The relationship with the wire gave a far more complex dependence and was not modeled theoretically. Comparison with the microbial challenge showed that for microholes a lower size limit was found to be 2 microm with a corresponding leak rate of 1.4 x 10(-3) mbarl/s. For the fine wire experiment the lower limit was 15-microm wire and a corresponding leak rate of 1.3 x 10(-5) mbarl/s. From these tests a safe, lower limit, leak rate was established.
Facile detection of Troponin I using dendritic platinum nanoparticles and capillary tube indicators.
Lee, Sanghee; Kwon, Donghoon; Yim, Changyong; Jeon, Sangmin
2015-01-01
A facile method was developed for the detection of Troponin I (TnI) using dendritic platinum nanoparticles and capillary tube indicators. Dendritic platinum nanoparticles were functionalized with TnI antibodies, which were used to capture TnI in human serum. The captured TnI was conjugated to the inner surface of a glass vial, to which a hydrogen peroxide (H2O2) solution was added. After the glass vial was sealed with a screw cap containing a silicon septum, a capillary tube containing a drop of ink was inserted through the septum. The catalytic dissociation of H2O2 to water and oxygen increased the pressure inside the glass vial and raised the ink level in the capillary tube. The ink level increased with the platinum nanoparticle concentration, which is proportional to the TnI concentration. The sensitivity of this assay for TnI in human serum after a 5 min dissociation reaction, detected with the naked eye, was 0.1 ng/mL, which was better than the sensitivity of the conventional colorimetric method using the TMB oxidation reaction under the same experimental conditions. A control experiment using alpha-fetoprotein, interleukin-5, and C-reactive protein revealed that the developed method was highly selective for the detection of TnI.
Measurement of tritium with plastic scintillator surface improvement with plasma treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshihara, Y.; Furuta, E.; Ohyama, R.I.
2015-03-15
Tritium is usually measured by using a liquid scintillation counter. However, liquid scintillator used for measurement will become radioactive waste fluid. To solve this issue, we have developed a method of measuring tritium samples with plasma-treated plastic scintillator (PS)sheets (Plasma method). The radioactive sample is held between 2 PS sheets and the whole is enclosed in a a low-potassium glass vial. With the Plasma method of 2-min plasma treatment, we have obtained measurement efficiency of 48 ± 2 % for 2 min measurement of tritium except for tritiated water. The plasma treatment makes the PS surface rough and hydrophilic whichmore » contributes to improve the contact between tritium and PS. On the other hand, it needed almost 6 hours to obtain constant measurement efficiency. The reason was that the dry-up handling in the vial needed longer time to vaporize H{sub 2}O molecules than in the air. We tried putting silica gel beads into vials to remove H{sub 2}O molecules from PS sheet surface quickly. The silica gel beads worked well and we got constant measurement efficiency within 1-3 hours. Also, we tried using other kinds of PS treated with plasma to obtain higher measurement efficiencies of tritium samples.« less
Ribeiro, Madelon Novato; Pimentel, Maria Inês Fernandes; Schubach, Armando de Oliveira; Oliveira, Raquel de Vasconcellos Carvalhães de; Teixeira, José Liporage; Leite, Madson Pedro da Silva; Fonseca, Monique; Santos, Ginelza Peres Lima dos; Salgueiro, Mariza Matos; Ferreira e Vasconcellos, Erica de Camargo; Lyra, Marcelo Rosandiski; Saheki, Mauricio Naoto; Valete-Rosalino, Claudia Maria
2014-01-01
The favorable outcome of the treatment of a disease is influenced by the adherence to therapy. Our objective was to assess factors associated with adherence to treatment of patients included in a clinical trial of equivalence between the standard and alternative treatment schemes with meglumine antimoniate (MA) in the treatment of cutaneous leishmaniasis (CL), in the state of Rio de Janeiro. Between 2008 and 2011, 57 patients with CL were interviewed using a questionnaire to collect socioeconomic data. The following methods were used for adherence monitoring: counting of vial surplus, monitoring card, Morisky test and modified Morisky test (without the question regarding the schedule); we observed 82.1% (vial return), 86.0% (monitoring card), 66.7% (Morisky test) and 86.0% (modified Morisky test) adherence. There was a strong correlation between the method of vial counting and the monitoring card and modified Morisky test. A significant association was observed between greater adherence to treatment and low dose of MA, as well as with a lower number of people sleeping in the same room. We recommend the use of the modified Morisky test to assess adherence to treatment of CL with MA, because it is a simple method and with a good performance, when compared to other methods.
Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants.
Kommers, D R; Broeren, Mac; Andriessen, P; Oei, S G; Feijs, L; Bambang Oetomo, S
2017-01-01
This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co-regulation. We also analysed possible influential determinants, including maternal oxytocin. The saliva of preterm infants and their mothers was collected prior to, and during, Kangaroo care using cotton swabs and pooled into vials until sufficient volumes were obtained to measure oxytocin levels using a radioimmunoassay. The obtrusiveness of the infants' collections was measured with a Likert scale. Saliva was collected unobtrusively prior to, and during, 30 Kangaroo care sessions in 21 preterm infants. This resulted in three vials with sufficient volumes of before-Kangaroo care saliva and three with during-Kangaroo care saliva. Oxytocin was detectable in all six vials. The Kangaroo care duration and the intensity of the mother-infant interaction before and during Kangaroo care seemed to be the most important determinants, and these should preferably be standardised in any future trials. Oxytocin was measured unobtrusively in the pooled saliva of preterm infants both before and during Kangaroo care and could therefore be investigated as a biomarker in future studies. ©2016 The Authors. Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica.
Shell-vial culture and real-time PCR applied to Rickettsia typhi and Rickettsia felis detection.
Segura, Ferran; Pons, Immaculada; Pla, Júlia; Nogueras, María-Mercedes
2015-11-01
Murine typhus is a zoonosis transmitted by fleas, whose etiological agent is Rickettsia typhi. Rickettsia felis infection can produces similar symptoms. Both are intracellular microorganisms. Therefore, their diagnosis is difficult and their infections can be misdiagnosed. Early diagnosis prevents severity and inappropriate treatment regimens. Serology can't be applied during the early stages of infection because it requires seroconversion. Shell-vial (SV) culture assay is a powerful tool to detect Rickettsia. The aim of the study was to optimize SV using a real-time PCR as monitoring method. Moreover, the study analyzes which antibiotics are useful to isolate these microorganisms from fleas avoiding contamination by other bacteria. For the first purpose, SVs were inoculated with each microorganism. They were incubated at different temperatures and monitored by real-time PCR and classical methods (Gimenez staining and indirect immunofluorescence assay). R. typhi grew at all temperatures. R. felis grew at 28 and 32 °C. Real-time PCR was more sensitive than classical methods and it detected microorganisms much earlier. Besides, the assay sensitivity was improved by increasing the number of SV. For the second purpose, microorganisms and fleas were incubated and monitored in different concentrations of antibiotics. Gentamicin, sufamethoxazole, trimethoprim were useful for R. typhi isolation. Gentamicin, streptomycin, penicillin, and amphotericin B were useful for R. felis isolation. Finally, the optimized conditions were used to isolate R. felis from fleas collected at a veterinary clinic. R. felis was isolated at 28 and 32 °C. However, successful establishment of cultures were not possible probably due to sub-optimal conditions of samples.
Methanogenic activity tests by Infrared Tunable Diode Laser Absorption Spectroscopy.
Martinez-Cruz, Karla; Sepulveda-Jauregui, Armando; Escobar-Orozco, Nayeli; Thalasso, Frederic
2012-10-01
Methanogenic activity (MA) tests are commonly carried out to estimate the capability of anaerobic biomass to treat effluents, to evaluate anaerobic activity in bioreactors or natural ecosystems, or to quantify inhibitory effects on methanogenic activity. These activity tests are usually based on the measurement of the volume of biogas produced by volumetric, pressure increase or gas chromatography (GC) methods. In this study, we present an alternative method for non-invasive measurement of methane produced during activity tests in closed vials, based on Infrared Tunable Diode Laser Absorption Spectroscopy (MA-TDLAS). This new method was tested during model acetoclastic and hydrogenotrophic methanogenic activity tests and was compared to a more traditional method based on gas chromatography. From the results obtained, the CH(4) detection limit of the method was estimated to 60 ppm and the minimum measurable methane production rate was estimated to 1.09(.)10(-3) mg l(-1) h(-1), which is below CH(4) production rate usually reported in both anaerobic reactors and natural ecosystems. Additionally to sensitivity, the method has several potential interests compared to more traditional methods among which short measurements time allowing the measurement of a large number of MA test vials, non-invasive measurements avoiding leakage or external interferences and similar cost to GC based methods. It is concluded that MA-TDLAS is a promising method that could be of interest not only in the field of anaerobic digestion but also, in the field of environmental ecology where CH(4) production rates are usually very low. Copyright © 2012 Elsevier B.V. All rights reserved.
Simple and accurate quantification of BTEX in ambient air by SPME and GC-MS.
Baimatova, Nassiba; Kenessov, Bulat; Koziel, Jacek A; Carlsen, Lars; Bektassov, Marat; Demyanenko, Olga P
2016-07-01
Benzene, toluene, ethylbenzene and xylenes (BTEX) comprise one of the most ubiquitous and hazardous groups of ambient air pollutants of concern. Application of standard analytical methods for quantification of BTEX is limited by the complexity of sampling and sample preparation equipment, and budget requirements. Methods based on SPME represent simpler alternative, but still require complex calibration procedures. The objective of this research was to develop a simpler, low-budget, and accurate method for quantification of BTEX in ambient air based on SPME and GC-MS. Standard 20-mL headspace vials were used for field air sampling and calibration. To avoid challenges with obtaining and working with 'zero' air, slope factors of external standard calibration were determined using standard addition and inherently polluted lab air. For polydimethylsiloxane (PDMS) fiber, differences between the slope factors of calibration plots obtained using lab and outdoor air were below 14%. PDMS fiber provided higher precision during calibration while the use of Carboxen/PDMS fiber resulted in lower detection limits for benzene and toluene. To provide sufficient accuracy, the use of 20mL vials requires triplicate sampling and analysis. The method was successfully applied for analysis of 108 ambient air samples from Almaty, Kazakhstan. Average concentrations of benzene, toluene, ethylbenzene and o-xylene were 53, 57, 11 and 14µgm(-3), respectively. The developed method can be modified for further quantification of a wider range of volatile organic compounds in air. In addition, the new method is amenable to automation. Copyright © 2016 Elsevier B.V. All rights reserved.
Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I
2013-08-09
Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.
De Beer, T R M; Vercruysse, P; Burggraeve, A; Quinten, T; Ouyang, J; Zhang, X; Vervaet, C; Remon, J P; Baeyens, W R G
2009-09-01
The aim of the present study was to examine the complementary properties of Raman and near infrared (NIR) spectroscopy as PAT tools for the fast, noninvasive, nondestructive and in-line process monitoring of a freeze drying process. Therefore, Raman and NIR probes were built in the freeze dryer chamber, allowing simultaneous process monitoring. A 5% (w/v) mannitol solution was used as model for freeze drying. Raman and NIR spectra were continuously collected during freeze drying (one Raman and NIR spectrum/min) and the spectra were analyzed using principal component analysis (PCA) and multivariate curve resolution (MCR). Raman spectroscopy was able to supply information about (i) the mannitol solid state throughout the entire process, (ii) the endpoint of freezing (endpoint of mannitol crystallization), and (iii) several physical and chemical phenomena occurring during the process (onset of ice nucleation, onset of mannitol crystallization). NIR spectroscopy proved to be a more sensitive tool to monitor the critical aspects during drying: (i) endpoint of ice sublimation and (ii) monitoring the release of hydrate water during storage. Furthermore, via NIR spectroscopy some Raman observations were confirmed: start of ice nucleation, end of mannitol crystallization and solid state characteristics of the end product. When Raman and NIR monitoring were performed on the same vial, the Raman signal was saturated during the freezing step caused by reflected NIR light reaching the Raman detector. Therefore, NIR and Raman measurements were done on a different vial. Also the importance of the position of the probes (Raman probe above the vial and NIR probe at the bottom of the sidewall of the vial) in order to obtain all required critical information is outlined. Combining Raman and NIR spectroscopy for the simultaneous monitoring of freeze drying allows monitoring almost all critical freeze drying process aspects. Both techniques do not only complement each other, they also provided mutual confirmation of specific conclusions.
Ramadan, Wijdan H; Khreis, Noura A; Kabbara, Wissam K
2015-01-01
Background The aim of the study was to evaluate the simplicity, safety, patients’ preference, and convenience of the administration of insulin using the pen device versus the conventional vial/syringe in patients with diabetes. Methods This observational study was conducted in multiple community pharmacies in Lebanon. The investigators interviewed patients with diabetes using an insulin pen or conventional vial/syringe. A total of 74 questionnaires were filled over a period of 6 months. Answers were entered into the Statistical Package for Social Sciences (SPSS) software and Excel spreadsheet. t-test, logistic regression analysis, and correlation analysis were used in order to analyze the results. Results A higher percentage of patients from the insulin pen users group (95.2%) found the method easy to use as compared to only 46.7% of the insulin conventional users group (P 0.001, relative risk [RR]: 2.041, 95% confidence interval [CI]: 1.178–3.535). Moreover, 61.9% and 26.7% of pen users and conventional users, respectively, could read the scale easily (P 0.037, RR 2.321, 95% CI: 0.940–5.731), while 85.7% of pen users found it more convenient shifting to pen and 86.7% of the conventional users would want to shift to pen if it had the same cost. Pain perception was statistically different between the groups. A much higher percentage (76.2%) of pen users showed no pain during injection compared to only 26.7% of conventional users (P 0.003, RR 2.857, 95% CI: 1.194–6.838). Conclusion The insulin pen was significantly much easier to use and less painful than the conventional vial/syringe. Proper education on the methods of administration/storage and disposal of needles/syringes is needed in both groups. PMID:25848231
Feasibility and Limitations of Vaccine Two-Dimensional Barcoding Using Mobile Devices.
Bell, Cameron; Guerinet, Julien; Atkinson, Katherine M; Wilson, Kumanan
2016-06-23
Two-dimensional (2D) barcoding has the potential to enhance documentation of vaccine encounters at the point of care. However, this is currently limited to environments equipped with dedicated barcode scanners and compatible record systems. Mobile devices may present a cost-effective alternative to leverage 2D vaccine vial barcodes and improve vaccine product-specific information residing in digital health records. Mobile devices have the potential to capture product-specific information from 2D vaccine vial barcodes. We sought to examine the feasibility, performance, and potential limitations of scanning 2D barcodes on vaccine vials using 4 different mobile phones. A unique barcode scanning app was developed for Android and iOS operating systems. The impact of 4 variables on the scan success rate, data accuracy, and time to scan were examined: barcode size, curvature, fading, and ambient lighting conditions. Two experimenters performed 4 trials 10 times each, amounting to a total of 2160 barcode scan attempts. Of the 1832 successful scans performed in this evaluation, zero produced incorrect data. Five-millimeter barcodes were the slowest to scan, although only by 0.5 seconds on average. Barcodes with up to 50% fading had a 100% success rate, but success rate deteriorated beyond 60% fading. Curved barcodes took longer to scan compared with flat, but success rate deterioration was only observed at a vial diameter of 10 mm. Light conditions did not affect success rate or scan time between 500 lux and 20 lux. Conditions below 20 lux impeded the device's ability to scan successfully. Variability in scan time was observed across devices in all trials performed. 2D vaccine barcoding is possible using mobile devices and is successful under the majority of conditions examined. Manufacturers utilizing 2D barcodes should take into consideration the impact of factors that limit scan success rates. Future studies should evaluate the effect of mobile barcoding on workflow and vaccine administrator acceptance.
Al-Sharayri, Mohammad G.; Aljbori, Tariq M.; Migdadi, Qusai M.; Al-Omoush, Marwa B.; Jaarah, Ayman R.
2013-01-01
Scope Recently, many publicly funded healthcare organizations suffered from an economical crisis. This forced some organizations to utilize less costly alternatives where possible. Insulin cartridges and vials are examples. Many patients are questioning the difference between the two alternatives as they contain the same active ingredient. Objective To find out if insulin cartridges really provide a lower risk of potential diabetes complications than traditional vials. Method A questionnaire was used to ask two random samples of diabetic patients about the development of some diabetes complications. The first sample (n = 41) consisted of patients using cartridges; the second sample (n = 40) consisted of patients using vials. Patients were randomly selected from the endocrine clinic and the out-patient pharmacy in Al-Hussein Hospital in King Hussein Medical Center in Amman- Jordan. Results 44% of respondents in the first sample did not suffer from any complication; on the other hand, the percentage was only 15% of respondents in the second sample. All respondents (100%) in the first sample suffered from only 2 complications or less; however, 25% of the respondents in the second sample suffered from 3 or more complications. Nephropathy complications, were slightly higher in the first sample; 22% compared to 15% in the second sample. On the other hand, all complications reported in the second sample were higher; 30% for neuropathy, 65% for retinopathy complications and 42.5% for extremities damage compared to only 9.7%, 7.3% and 26.8% respectively in the first sample. Conclusion In general, respondents who were using cartridges reported a lesser incidence of diabetes complications. Although many organizations suffered from an economical crisis, the cost-effectiveness aspect should be taken into consideration when purchasing medical alternatives. This will provide higher quality of life for patients and eventually lower hidden and future costs for the organizations. PMID:25161382
Al-Sharayri, Mohammad G; Aljbori, Tariq M; Migdadi, Qusai M; Al-Omoush, Marwa B; Jaarah, Ayman R
2014-09-01
Recently, many publicly funded healthcare organizations suffered from an economical crisis. This forced some organizations to utilize less costly alternatives where possible. Insulin cartridges and vials are examples. Many patients are questioning the difference between the two alternatives as they contain the same active ingredient. To find out if insulin cartridges really provide a lower risk of potential diabetes complications than traditional vials. A questionnaire was used to ask two random samples of diabetic patients about the development of some diabetes complications. The first sample (n = 41) consisted of patients using cartridges; the second sample (n = 40) consisted of patients using vials. Patients were randomly selected from the endocrine clinic and the out-patient pharmacy in Al-Hussein Hospital in King Hussein Medical Center in Amman- Jordan. 44% of respondents in the first sample did not suffer from any complication; on the other hand, the percentage was only 15% of respondents in the second sample. All respondents (100%) in the first sample suffered from only 2 complications or less; however, 25% of the respondents in the second sample suffered from 3 or more complications. Nephropathy complications, were slightly higher in the first sample; 22% compared to 15% in the second sample. On the other hand, all complications reported in the second sample were higher; 30% for neuropathy, 65% for retinopathy complications and 42.5% for extremities damage compared to only 9.7%, 7.3% and 26.8% respectively in the first sample. In general, respondents who were using cartridges reported a lesser incidence of diabetes complications. Although many organizations suffered from an economical crisis, the cost-effectiveness aspect should be taken into consideration when purchasing medical alternatives. This will provide higher quality of life for patients and eventually lower hidden and future costs for the organizations.
Development of a primary diffusion source of organic vapors for gas analyzer calibration
NASA Astrophysics Data System (ADS)
Lecuna, M.; Demichelis, A.; Sassi, G.; Sassi, M. P.
2018-03-01
The generation of reference mixtures of volatile organic compounds (VOCs) at trace levels (10 ppt-10 ppb) is a challenge for both environmental and clinical measurements. The calibration of gas analyzers for trace VOC measurements requires a stable and accurate source of the compound of interest. The dynamic preparation of gas mixtures by diffusion is a suitable method for fulfilling these requirements. The estimation of the uncertainty of the molar fraction of the VOC in the mixture is a key step in the metrological characterization of a dynamic generator. The performance of a dynamic generator was monitored over a wide range of operating conditions. The generation system was simulated by a model developed with computational fluid dynamics and validated against experimental data. The vapor pressure of the VOC was found to be one of the main contributors to the uncertainty of the diffusion rate and its influence at 10-70 kPa was analyzed and discussed. The air buoyancy effect and perturbations due to the weighing duration were studied. The gas carrier flow rate and the amount of liquid in the vial were found to play a role in limiting the diffusion rate. The results of sensitivity analyses were reported through an uncertainty budget for the diffusion rate. The roles of each influence quantity were discussed. A set of criteria to minimize the uncertainty contribution to the primary diffusion source (25 µg min-1) were estimated: carrier gas flow rate higher than 37.7 sml min-1, a maximum VOC liquid mass decrease in the vial of 4.8 g, a minimum residual mass of 1 g and vial weighing times of 1-3 min. With this procedure a limit uncertainty of 0.5% in the diffusion rate can be obtained for VOC mixtures at trace levels (10 ppt-10 ppb), making the developed diffusion vials a primary diffusion source with potential to become a new reference material for trace VOC analysis.
Parikh, Alpa; van de Rijn, Jennifer; Melville, Chris; Sarkari, Marazban; Peltier, Sylvie; McKean, Robert
2018-04-01
Purpose Omacetaxine mepesuccinate ("omacetaxine") is approved by the US Food and Drug Administration for the treatment of adult patients with chronic- or accelerated-phase chronic myeloid leukemia with resistance and/or intolerance to two or more tyrosine kinase inhibitors. In May 2014, the US Food and Drug Administration approved revisions to the packaging information that included directions for home administration of reconstituted omacetaxine by patients or caregivers using syringes filled at a healthcare facility. We developed recommendations for the transport, storage, and spill-clean procedure of reconstituted omacetaxine for home and clinic administration. Methods We conducted chemical stability and microbial growth studies of reconstituted omacetaxine solution stored in vials and syringes at room temperature or refrigerated for various durations. Several shipping configurations were tested in simulated transport conditions to evaluate their ability to contain solution leakage and maintain product quality during distribution. In addition, we evaluated cleaning products and procedures for their effectiveness in removing residual omacetaxine from household surfaces after mock spills. Results Reconstituted omacetaxine showed limited degradation when refrigerated for 14 days in vials and syringes, and no microbial growth was observed for 12 days after intentional inoculation. In shipping studies, the configurations maintained prepared syringes within the recommended storage temperature range throughout transport and could contain leaks if spills occurred. In the event of an accidental spill in a home environment, effective cleaning can be achieved using household cleaning products and defined procedures. Conclusion These data provide important information regarding the safe transportation and administration of reconstituted omacetaxine in the home and clinic.
An intradermal skin test for determination of immunity to varicella
Somekh, E; Bujanover, Y; Tal, G; Dalal, I; Tanay, A; Lehman, D
2001-01-01
AIMS—To evaluate the usefulness of a diluted, inactivated solution of attenuated varicella vaccine in predicting susceptibility to varicella and its correlation with specific antibody titre to varicella. METHODS—In a prospective blinded study, 63 healthy subjects (aged 2-43 years) were studied. Skin test solution was prepared from vials of OKA strain virus which was inactivated by exposure of the vials to room temperature for 10 days; solution was diluted at 1/50 with normal saline and kept at 4°C until used for skin testing. The material was injected intradermally. Serum samples were drawn prior to skin testing and kept at −70°C until analysis for antibody assay by the indirect fluorescent antibody (IFA) method. RESULTS—Forty three patients were IFA antibody positive; 41 of them reacted to the skin test. One of the 20 IFA negative patients reacted to the skin test. Sixteen patients had two serological tests performed, one month apart. Four out of these 16 patients tested negative with the skin test. All four had negative serology on both samples. Six of the 12 IFA positive patients showed a boost in the antibody titre one month after application of the skin test. The specificity and sensitivity of the skin test compared to the IFA assay were both 95%, and the positive and negative predictive values were 97% and 90% respectively. CONCLUSIONS—Results suggest that a varicella skin test prepared using this simple and relatively cheap method is a safe, sensitive, and specific tool by which to assess immunity to varicella. PMID:11719333
Fowler, Amanda L; Hughes, Darrel W; Muir, Mark T; VanWert, Elizabeth M; Gamboa, Conrado D; Myers, John G
2017-12-01
Crotaline envenomation clinical manifestations vary considerably among patients. Current recommendations for treatment with Crotalidae polyvalent immune Fab require assessment of envenomation control. Determining control of envenomation, particularly when patients are evaluated by different providers in separate clinical settings, can be difficult. To determine if a difference in total vials of Crotalidae antivenin therapy exists between pre-protocol and post-Snakebite Severity Score (SSS) protocol. Retrospective medical record review at an academic medical and regional Level I trauma center. Resource utilization in patients with a diagnosis of "snakebite" was compared between patients treated pre- and post-SSS protocol implementation. One hundred forty-six patients were included in the evaluation. One hundred twenty-seven (87.0%) patients received antivenin, n = 80 (90.9%) in the pre-protocol group and n = 47 (81.0%) in the post-protocol group. Median total number of antivenin vials per patient was lower in the post-protocol group than the pre-protocol group, 16 (10-24 interquartile range) vs. 12 (10-16 interquartile range), p = 0.006. This decreased utilization correlates to an approximate $13,200 savings per patient. Hospital and intensive care unit length of stay, opioid use, incidence of blood product transfusion, need for surgical intervention, or need for intubation were not different between groups. A snakebite protocol with SSS utilization to guide antivenin administration results in significantly decreased antivenin therapy in snakebite patients without increase in other health care utilization. Copyright © 2017 Elsevier Inc. All rights reserved.
Cannon, Robert; Ruha, Anne-Michelle; Kashani, John
2008-04-01
Acute hypersensitivity reactions are well known to occur with the administration of the Antivenin (Crotalidae) Polyvalent (Wyeth Laboratories, Marietta, PA). Crotalidae polyvalent immune Fab (ovine) (CroFab; FabAV, Protherics, Inc., Brentwood, TN) was introduced in 2001, and early studies reported a hypersensitivity reaction rate up to 19%. We describe the incidence of acute hypersensitivity reactions to FabAV in patients bitten by rattlesnakes. This was a nonconcurrent observational cohort study, with data obtained by chart review of all patients admitted to our service for rattlesnake bites from July 2000 to June 2004. The study was conducted at an urban Level I trauma center and urban children's hospital. All patients treated with FabAV were included. Those who received no antivenom or who were treated with Antivenin (Crotalidae) Polyvalent were excluded. The main outcome variable was whether an acute hypersensitivity reaction developed. Ninety-three patients were included in the review (72 male and 21 female patients). The mean age was 34.5 years (range 16 months to 91 years), and the mean dose of antivenom was 12 vials (range 4 to 32 vials). The incidence of acute hypersensitivity reactions was 5 of 93, or 5.4%. Four patients developed a mild reaction that was easily treated and were able to finish the full course of antivenom. Only 1 patient developed a reaction that prevented further antivenom administration. FabAV appears to be associated with a lower incidence of acute hypersensitivity than initially reported. Most reactions are mild and easily treated and do not preclude further dosing of antivenom.
Purification and labeling strategies for (68)Ga from (68)Ge/ (68)Ga generator eluate.
Mueller, Dirk; Klette, Ingo; Baum, Richard P
2013-01-01
For successful labeling, (68)Ge/(68)Ga generator eluate has to be concentrated (from 10 mL or more to less than 1 mL) and to be purified of metallic impurities, especially Fe(III), and (68)Ge breakthrough. Anionic, cationic and fractional elution methods are well known. We describe two new methods: (1) a combined cationic-anionic purification and (2) an easy-to-use and reliable cationic purification with NaCl solution. Using the first method, (68)Ga from 10 mL generator eluate was collected on a SCX cartridge, then eluted with 1.0 mL 5.5 M HCl directly on an anion exchanger (30 mg AG1X8). After drying with a stream of helium, (68)Ga was eluted with 0.4 mL water into the reaction vial. We provide as an example labeling of BPAMD. Using the second method, (68)Ga from 10 mL generator eluate was collected on a SCX cartridge, then eluted with a hydrochloric solution of sodium chloride (0.5 mL 5 M NaCl, 12.5 μL 5.5 M HCl) into the reaction vial, containing 40 μg DOTATOC and 0.5 mL 1 M ammonium acetate buffer pH 4.5. After heating for 7 min at 90°C, the reaction was finished. Radiochemical purity was higher than 95% without further purification. No (68)Ge breakthrough was found in the final product.
Wojciechowski, Karen L; Melilli, Caterina; Barbano, David M
2014-09-01
Our objectives were to determine if mixing and sampling of a raw milk sample at 4°C for determination of total bacteria count (TBC) and if incubation at 14°C for 18h and sampling for a preliminary incubation (PI) count influenced the accuracy of subsequent fat, protein, or lactose measurement by mid-infrared (IR) analysis of milk from the same sample container due to either nonrepresentative sampling or the presence of microbial metabolites produced by microbial growth in the milk from the incubation. Milks of 4 fat levels (2.2, 3, 4, and 5%) reflected the range of fat levels encountered in producer milks. If the portion of milk removed from a cold sample was not representative, then the effect on a milk component test would likely be larger as fat content increases. Within the milks at each fat level, 3 treatments were used: (1) 20 vials of the same milk sampled for testing TBC using a BactoScan FC and then used for a milk component test; (2) 20 vials for testing TBC plus PI count followed by component test; and (3) 20 vials to run for IR component test without a prior micro sampling and testing. This was repeated in 3 different weeks using a different batch of milk each week. No large effect on the accuracy of component milk testing [IR fat B (carbon hydrogen stretch) and fat A (carbonyl stretch)] due to the cold milk sample handling and mixing procedures used for TBC was detected, confirming the fact that the physical removal of milk from the vial by the BactoScan FC (Foss Electric, Hillerød, Denmark) was a representative portion of the milk. However, the representativeness of any other sampling procedure (manual or automated) of a cold milk sample before running milk component testing on the same container of milk should be demonstrated and verified periodically as a matter of routine laboratory quality assurance. Running TBC with a BactoScan FC first and then IR milk analysis after had a minimal effect on milk component tests by IR when milk bacteria counts were within pasteurized milk ordinance limits of <100,000 cfu/mL. Running raw milk PI counts (18h of incubation at 13-14°C) with the BactoScan FC before milk component testing by IR milk analysis had an effect on component tests. The effect was largest on fat test results and would decrease the accuracy of milk payment testing on individual producer milks. The effect was most likely due to the absorption of light by bacterial metabolites resulting from microbial growth or other chemical degradation processes occurring in the milk during the PI count incubation, not by the sampling procedure of the BactoScan. The direction of the effect on component test results will vary depending on the bacteria count and the type of bacteria that grew in the milk, and this could be different in every individual producer milk sample. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Lim, Adeline Y L; Singh, Puneet N; Isbister, Geoffrey K
2016-07-01
Envenoming by the Australian red-bellied black snake (Pseudechis porphyriacus) causes non-specific systemic symptoms, anticoagulant coagulopathy, myotoxicity and local effects. Current management for systemic envenoming includes administration of one vial of tiger snake antivenom within 6 h of the bite to prevent myotoxicity. We present a case of severe rhabdomyolysis in a 16 year old male which developed despite early administration of one vial of tiger snake antivenom. Free venom was detected after the administration of antivenom concurrent with rapidly decreasing antivenom concentrations. The case suggests that insufficient antivenom was administered and the use of larger doses of antivenom need to be explored for red-bellied black snake envenoming. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ata, A; Abali, H; Yengel, E; Arican, A
2012-01-01
Cancer therapy is a costly treatment. Costs of drugs used in cancer therapy are gradually increasing with the addition of new and expensive drugs. This fact imposes obligation on reasonable drug usage. Occasionally, all of the prescribed drugs are not used for various reasons, and a number of drugs can be left over. In this study, we aimed to calculate the costs of unused chemotherapeutic drugs in our oncology clinics. A total of 117 patients with 17 different types of cancer were administered 32 cancer therapy protocols during 2 months. After administration of ideal doses of the prescribed drugs calculated on an individual basis, the number of unused drug doses in the packages was recorded and the costs of the unused drugs were calculated based on current prices of the drugs. The cumulative cost of the unused drugs calculated for all patients was US dollars (USD) 6406.93, and average cost of the drug per capita was USD 54.76. Minimal and maximal unused drug costs per drug were USD 0.29 for 5-fluorouracil, and USD 247.12 for bevacizumab, respectively. Minimal increase in drug costs per recipe was USD 0.50 for a prescription containing cyclophosphamide and 5-fluorouracil, while the total cost of bevacizumab plus irinotecan combination increased tremendously to USD 309.12. Among chemotherapeutic protocols the cheapest one was AC (adriamycin, cyclophosphamide) with USD 4.77, while the most expensive one (USD 116.02) was FOLFIRI-B (5-fluorouracil, calcium folinate, irinotecan, and bevacizumab). The important financial burden of unused drugs goes unrecognized among routine chemotherapeutic applications. In order to be able to avoid this extravagance, drug industry, prescribing physicians, and practice nurses must assume important roles.
Limeres Posse, J; Álvarez Fernández, M; Fernández Feijoo, J; Medina Henríquez, J; Lockhart, P B; Chu, V H; Diz Dios, P
2016-07-01
Although controversy exists regarding the efficacy of antibiotic prophylaxis for patients at risk of infective endocarditis, expert committees continue to publish recommendations for antibiotic prophylaxis regimens. This study aimed to evaluate the efficacy of four antimicrobial regimens for the prevention of bacteraemia following dental extractions. The study population included 266 adults requiring dental extractions who were randomly assigned to the following five groups: control (no prophylaxis); 1000/200 mg of amoxicillin/clavulanate intravenously; 2 g of amoxicillin by mouth; 600 mg of clindamycin by mouth; and 600 mg of azithromycin by mouth. Venous blood samples were collected from each patient at baseline and at 30 s, 15 min and 1 h after dental extractions. Samples were inoculated into BACTEC Plus culture bottles and processed in the BACTEC 9240. Conventional microbiological techniques were used for subcultures and further identification of the isolated bacteria. The trial was registered at ClinicalTrials.gov with ID number NCT02115776. The incidence of bacteraemia in the control, amoxicillin/clavulanate, amoxicillin, clindamycin and azithromycin groups was: 96%, 0%, 50%, 87% and 81%, respectively, at 30 s; 65%, 0%, 10%, 65% and 49% at 15 min; and 18%, 0%, 4%, 19% and 18% at 1 h. Streptococci were the most frequently identified bacteria. The percentage of positive blood cultures at 30 s post-extraction was lower in the amoxicillin/clavulanate group than in the amoxicillin group (P < 0.001). The incidence of bacteraemia in the clindamycin group was similar to that in the control group. Bacteraemia following dental extractions was undetectable with amoxicillin/clavulanate prophylaxis. Alternative antimicrobial regimens should be sought for patients allergic to the β-lactams. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Atehnkeng, J; Ojiambo, P S; Ikotun, T; Sikora, R A; Cotty, P J; Bandyopadhyay, R
2008-10-01
Aflatoxin contamination resulting from maize infection by Aspergillus flavus is both an economic and a public health concern. Therefore, strategies for controlling aflatoxin contamination in maize are being investigated. The abilities of eleven naturally occurring atoxigenic isolates in Nigeria to reduce aflatoxin contamination in maize were evaluated in grain competition experiments and in field studies during the 2005 and 2006 growing seasons. Treatments consisted of inoculation of either grains in vials or ears at mid-silking stage in field plots, with the toxigenic isolate (La3228) or atoxigenic isolate alone and co-inoculation of each atoxigenic isolate and La3328. Aflatoxin B(1) + B(2) concentrations were significantly (p < 0.05) lower in the co-inoculation treatments compared with the treatment in which the aflatoxin-producing isolate La3228 was inoculated alone. Relative levels of aflatoxin B(1) + B(2) reduction ranged from 70.1% to 99.9%. Among the atoxigenics, two isolates from Lafia, La3279 and La3303, were most effective at reducing aflatoxin B(1) + B(2) concentrations in both laboratory and field trials. These two isolates have potential value as agents for the biocontrol of aflatoxin contamination in maize. Because these isolates are endemic to West Africa, they are both more likely than introduced isolates to be well adapted to West African environments and to meet regulatory concerns over their use throughout that region.
A Practical Guide to Experimental Geometrical Optics
NASA Astrophysics Data System (ADS)
Garbovskiy, Yuriy A.; Glushchenko, Anatoliy V.
2017-12-01
Preface; 1. Markets of optical materials, components, accessories, light sources and detectors; 2. Introduction to optical experiments: light producing, light managing, light detection and measuring; 3. Light detectors based on semiconductors: photoresistors, photodiodes in a photo-galvanic regime. Principles of operation and measurements; 4. Linear light detectors based on photodiodes; 5. Basic laws of geometrical optics: experimental verification; 6. Converging and diverging thin lenses; 7. Thick lenses; 8. Lens systems; 9. Simple optical instruments I: the eye and the magnifier, eyepieces and telescopes; 10. Simple optical instruments II: light illuminators and microscope; 11. Spherical mirrors; 12. Introduction to optical aberrations; 13. Elements of optical radiometry; 14. Cylindrical lenses and vials; 15. Methods of geometrical optics to measure refractive index; 16. Dispersion of light and prism spectroscope; 17. Elements of computer aided optical design; Index.
Hinsmann, P; Arce, L; Ríos, A; Valcárcel, M
2000-01-07
The separation of seven pesticides by micellar electrokinetic capillary chromatography in spiked water samples is described, allowing the analysis of pesticides mixtures down to a concentration of 50 microg l(-1) in less than 13 min. Calibration, pre-concentration, elution and injection into the sample vial was carried out automatically by a continuous flow system (CFS) coupled to a capillary electrophoresis system via a programmable arm. The whole system was electronically coupled by a micro-processor and completely controlled by a computer. A C18 solid-phase mini-column was used for the pre-concentration, allowing a 12-fold enrichment (as an average value) of the pesticides from fortified water samples. Under the optimal extraction conditions, recoveries between 90 and 114% for most of the pesticides were obtained.
Modular radiochemistry synthesis system
Satyamurthy, Nagichettiar; Barrio, Jorge R.; Amarasekera, Bernard; Van Dam, Michael R.; Olma, Sebastian; Williams, Dirk; Eddings, Mark; Shen, Clifton Kwang-Fu
2016-11-01
A modular chemical production system includes multiple modules for performing a chemical reaction, particularly of radiochemical compounds, from a remote location. One embodiment comprises a reaction vessel including a moveable heat source with the position thereof relative to the reaction vessel being controllable from a remote position. Alternatively the heat source may be fixed in location and the reaction vial is moveable into and out of the heat source. The reaction vessel has one or more sealing plugs, the positioning of which in relationship to the reaction vessel is controllable from a remote position. Also the one or more reaction vessel sealing plugs can include one or more conduits there through for delivery of reactants, gases at atmospheric or an elevated pressure, inert gases, drawing a vacuum and removal of reaction end products to and from the reaction vial, the reaction vial with sealing plug in position being operable at elevated pressures. The modular chemical production system is assembled from modules which can each include operating condition sensors and controllers configured for monitoring and controlling the individual modules and the assembled system from a remote position. Other modules include, but are not limited to a Reagent Storage and Delivery Module, a Cartridge Purification Module, a Microwave Reaction Module, an External QC/Analysis/Purification Interface Module, an Aliquotting Module, an F-18 Drying Module, a Concentration Module, a Radiation Counting Module, and a Capillary Reactor Module.
Brouckaert, Davinia; De Meyer, Laurens; Vanbillemont, Brecht; Van Bockstal, Pieter-Jan; Lammens, Joris; Mortier, Séverine; Corver, Jos; Vervaet, Chris; Nopens, Ingmar; De Beer, Thomas
2018-04-03
Near-infrared chemical imaging (NIR-CI) is an emerging tool for process monitoring because it combines the chemical selectivity of vibrational spectroscopy with spatial information. Whereas traditional near-infrared spectroscopy is an attractive technique for water content determination and solid-state investigation of lyophilized products, chemical imaging opens up possibilities for assessing the homogeneity of these critical quality attributes (CQAs) throughout the entire product. In this contribution, we aim to evaluate NIR-CI as a process analytical technology (PAT) tool for at-line inspection of continuously freeze-dried pharmaceutical unit doses based on spin freezing. The chemical images of freeze-dried mannitol samples were resolved via multivariate curve resolution, allowing us to visualize the distribution of mannitol solid forms throughout the entire cake. Second, a mannitol-sucrose formulation was lyophilized with variable drying times for inducing changes in water content. Analyzing the corresponding chemical images via principal component analysis, vial-to-vial variations as well as within-vial inhomogeneity in water content could be detected. Furthermore, a partial least-squares regression model was constructed for quantifying the water content in each pixel of the chemical images. It was hence concluded that NIR-CI is inherently a most promising PAT tool for continuously monitoring freeze-dried samples. Although some practicalities are still to be solved, this analytical technique could be applied in-line for CQA evaluation and for detecting the drying end point.
Teska, Brandon M; Brake, Jeffrey M; Tronto, Gregory S; Carpenter, John F
2016-07-01
We examined the effects of an accelerated agitation protocol on 2 protein therapeutics, intravenous immunoglobulin (IVIG) and Avastin (bevacizumab), in contact with a novel fluoropolymer surface and more typical siliconized surfaces. The fluoropolymer surface provides "solid-phase" lubrication for the syringe plunger-obviating the need for silicone oil lubrication in prefilled syringes. We tested the 2 surfaces in a vial system and in prefilled glass syringes. We also examined the effects of 2 buffers, phosphate-buffered saline (PBS) and 0.2-M glycine, with and without the addition of polysorbate 20, on agitation-induced aggregation of IVIG. Aggregation was monitored by measuring subvisible particle formation and soluble protein loss. In both vials and syringes, protein particle formation was much lower during agitation with the fluoropolymer surface than with the siliconized surface. Also, particle formation was greater in PBS than in glycine buffer, an effect attributed to lower colloidal stability of IVIG in PBS. Polysorbate 20 in the formulation greatly inhibited protein particle formation. Overall, the fluoropolymer plunger surface in an unsiliconized glass barrel was demonstrated to be a viable solution for eliminating silicone oil droplets from prefilled syringe formulations and providing a consistent system for rationale formulation development and simplified particle analysis. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Modular radiochemistry synthesis system
Satyamurthy, Nagichettiar; Barrio, Jorge R.; Amarasekera, Bernard; Van Dam, R. Michael; Olma, Sebastian; Williams, Dirk; Eddings, Mark; Shen, Clifton Kwang-Fu
2015-12-15
A modular chemical production system includes multiple modules for performing a chemical reaction, particularly of radiochemical compounds, from a remote location. One embodiment comprises a reaction vessel including a moveable heat source with the position thereof relative to the reaction vessel being controllable from a remote position. Alternatively the heat source may be fixed in location and the reaction vial is moveable into and out of the heat source. The reaction vessel has one or more sealing plugs, the positioning of which in relationship to the reaction vessel is controllable from a remote position. Also the one or more reaction vessel sealing plugs can include one or more conduits there through for delivery of reactants, gases at atmospheric or an elevated pressure, inert gases, drawing a vacuum and removal of reaction end products to and from the reaction vial, the reaction vial with sealing plug in position being operable at elevated pressures. The modular chemical production system is assembled from modules which can each include operating condition sensors and controllers configured for monitoring and controlling the individual modules and the assembled system from a remote position. Other modules include, but are not limited to a Reagent Storage and Delivery Module, a Cartridge Purification Module, a Microwave Reaction Module, an External QC/Analysis/Purification Interface Module, an Aliquotting Module, an F-18 Drying Module, a Concentration Module, a Radiation Counting Module, and a Capillary Reactor Module.
Modular radiochemistry synthesis system
Satyamurthy, Nagichettiar; Barrio, Jorge R; Amarasekera, Bernard; Van Dam, R. Michael; Olma, Sebastian; Williams, Dirk; Eddings, Mark A; Shen, Clifton Kwang-Fu
2015-02-10
A modular chemical production system includes multiple modules for performing a chemical reaction, particularly of radiochemical compounds, from a remote location. One embodiment comprises a reaction vessel including a moveable heat source with the position thereof relative to the reaction vessel being controllable from a remote position. Alternatively the heat source may be fixed in location and the reaction vial is moveable into and out of the heat source. The reaction vessel has one or more sealing plugs, the positioning of which in relationship to the reaction vessel is controllable from a remote position. Also the one or more reaction vessel sealing plugs can include one or more conduits there through for delivery of reactants, gases at atmospheric or an elevated pressure, inert gases, drawing a vacuum and removal of reaction end products to and from the reaction vial, the reaction vial with sealing plug in position being operable at elevated pressures. The modular chemical production system is assembled from modules which can each include operating condition sensors and controllers configured for monitoring and controlling the individual modules and the assembled system from a remote position. Other modules include, but are not limited to a Reagent Storage and Delivery Module, a Cartridge Purification Module, a Microwave Reaction Module, an External QC/Analysis/Purification Interface Module, an Aliquotting Module, an F-18 Drying Module, a Concentration Module, a Radiation Counting Module, and a Capillary Reactor Module.
21 CFR 529.2464 - Ticarcillin.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Specifications. Each vial contains ticarcillin disodium powder equivalent to 6 grams of ticarcillin for... 6 grams daily by intrauterine infusion for 3 consecutive days during estrus. (2) Indications for use...
Mycobacteriosis due to Mycobacterium genavense in six pet birds.
Hoop, R K; Böttger, E C; Ossent, P; Salfinger, M
1993-01-01
Six cases of mycobacteriosis due to Mycobacterium genavense in three budgerigars (Melopsittacus undulatus), one orange-winged amazon (Amazona amazonica), one flycatcher (Cyanoptila cyanomelana), and one zebra finch (Taeniopygia guttata) are discussed. Gross lesions associated with the infection included a high degree of muscular wasting (five cases), hepatomegaly (four cases), and thickening of the wall of the small intestine (four cases). Granulomas were found in the lung (one case) and the subcutis (one case). Acid-fast bacilli were detected in the liver of all six birds. Only the use of acidic BACTEC mediums consistently led to growth, whereas the egg-based medium failed. These findings point to a possible role of the environment as a reservoir for M. genavense. Images PMID:8463407
Structure and magnetic properties of mechanically alloyed Co and Co-Ni
NASA Astrophysics Data System (ADS)
Guessasma, S.; Fenineche, N.
The influence of milling process on magnetic properties of Co and Co-Ni materials is studied. Coercivity, squareness ratio and crystallite size of mechanically alloyed Co-Ni material were related to milling time. For Co material, coercivity, cubic phase ratio and crystallite size were related to milling energy considering the vial and plateau rotation velocities. An artificial neural network (ANN) combining the parameters for both materials is used to predict magnetic and structure results versus milling conditions. Predicted results showed that milling energy is mostly dependent on the ratio vial to plateau rotation velocities and that milling times larger than 40 h do not add significant change to both structure and magnetic responses. Magnetic parameters were correlated to crystallite size and the D 6 law was only valid for small sizes.
Accuracy Considerations in Sterile Compounding.
Akers, Michael J
2017-01-01
Published information about the accuracy of filling and closing operations of sterile products is limited and guidelines on the topic are very general. This article highlights the basic principles in sterile-product filling of syringes and vials. Also covered in this article are descriptions of some of the available devices for filling containers, a brief discussion of the advances in vial and syringe filling, a discussion on the advantages and disadvantages of sterile product filling methods, and a discussion on possible problems encountered during filling operations. Because of the extremely high costs of some new drugs, especially biopharmaceuticals, compounding pharmacies may prefer to fill small batches to reduce the risk of unacceptable monetary losses in the event of a manufacturing deviation that results in batch rejection. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
1982-07-16
el_ STATON STATbON NA ViAlS 24 HOUR AMOUNTS IN INCHES MYwA JAN FES MAR APR MAY JUN JUL. AUG. SEP. OCT. NOV. OEC MOLTS ., . 3. 7. S__3 5. 5.1 2 A T. k...344I1 6? -! -" 171 1*1 16 16 _311_302 lement Ill) ZX8 21 M e. Obra . Mame me. of Newe Wilk To e mtw" Rol. lio. *Towl wet sikll, a". Poin IN ,e " ’ ..4...569 NATRONA CO/CASPER WY 73-61 $’AT ON ST-ATIO. N ANE viAls MRS L S T i JAN FES MAN APR MAY JUNl Jut AUG SEP OCT NO0V DEC ANNUAL MEAN 124*61824.&2324
Famewo, Elizabeth B; Clarke, Anna M; Wiid, Ian; Ngwane, Andile; van Helden, Paul; Afolayan, Anthony J
2017-09-01
The emergence of drug-resistant strains of Mycobacterium tuberculosis has become a global public health problem. Polyherbal medicines offer great hope for developing alternative drugs for the treatment of tuberculosis. To evaluate the anti-tubercular activity of polyherbal medicines used for the treatment of tuberculosis. The remedies were screened against Mycobacterium tuberculosis H37Rv using Middlebrook 7H9 media and MGIT BACTEC 960 system. They were liquid preparations from King Williams Town site A (KWTa), King Williams Town site B (KWTb), King Williams Town site C (KWTc), Hogsback first site (HBfs), Hogsback second site (HBss), Hogsback third site (HBts), East London (EL), Alice (AL) and Fort Beaufort (FB). The susceptibility testing revealed that all the remedies contain anti-tubercular activity with KWTa, KWTb, KWTc, HBfs, HBts, AL and FB exhibiting more activity at a concentration below 25 µl/ml. Furthermore, MIC values exhibited inhibitory activity with the most active remedies from KWTa, HBfs and HBts at 1.562 µg/ml. However, isoniazid showed more inhibitory activity against M. tuberculosis at 0.05 µg/ml when compare to the polyherbal remedies. This study has indicated that these remedies could be potential sources of new anti-mycobacterial agents against M. tuberculosis . However, the activity of these preparations and their active principles still require in vivo study in order to assess their future as new anti-tuberculosis agents.
Mathaes, Roman; Mahler, Hanns-Christian; Roggo, Yves; Huwyler, Joerg; Eder, Juergen; Fritsch, Kamila; Posset, Tobias; Mohl, Silke; Streubel, Alexander
2016-01-01
Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters (e.g., pre-compression force, capping plate height, turntable rotating speed) contribute to the final residual seal force of a sealed container closure system and its relation to container closure integrity and other drug product quality parameters. Stopper compression measured by computer tomography correlated to residual seal force measurements.In our studies, we used different container closure system configurations from different good manufacturing practice drug product fill & finish facilities to investigate the influence of differences in primary packaging, that is, vial size and rubber stopper design on the capping process and the capped drug product. In addition, we compared two large-scale good manufacturing practice manufacturing capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force.The capping plate to plunger distance had a major influence on the obtained residual seal force values of a sealed vial, whereas the capping pre-compression force and the turntable rotation speed showed only a minor influence on the residual seal force of a sealed vial. Capping process parameters could not easily be transferred from capping equipment of different manufacturers. However, the residual seal force tester did provide a valuable tool to compare capping performance of different capping equipment. No vial showed any leakage greater than 10(-8)mbar L/s as measured by a helium mass spectrometry system, suggesting that container closure integrity was warranted in the residual seal force range tested for the tested container closure systems. Capping equipment used in good manufacturing practice manufacturing features different designs and a variety of adjustable process parameters. The overall capping result is a complex interplay of the different capping process parameters and is insufficiently described in the literature. It remains poorly studied how the different capping equipment designs and capping equipment process parameters contribute to the final capping result.In this study, we used different container closure system configurations from different good manufacturing process drug product fill & finish facilities to investigate the influence of the vial size and the rubber stopper design on the capping process. In addition, we compared two examples of large-scale good manufacturing process capping equipment and different capping equipment settings and their impact on product quality and integrity, as determined by residual seal force. © PDA, Inc. 2016.
Miller, N C; Harris, M F
1994-01-01
Since vaccines may lose their potency if transported or stored outside the recommended temperature range (2-8 degrees C), we carried out a study in the Darwin area of the Northern Territory of Australia to determine the links in the cold chain, including the extent of vaccine monitoring, and whether the vaccines were being exposed to unsafe temperatures. Sabin oral poliomyelitis vaccine (OPV) and recombinant hepatitis-B (HB) vaccine were selected for special monitoring. A total of 127 vials of OPV and 144 vials of HB vaccine were dispatched during October, November and December 1990 to the government, independent health services and general practitioner surgeries which routinely administer these vaccines. We distributed the two vaccines with MonitorMark time/temperature and Coldside indicator tags attached to cards for recording the date, location and temperature exposures each time the vaccines were moved or used. A total of 65% of the OPV and 41% of the HB vaccine monitor cards were returned for analysis. The vaccines were transported and stored at one to four locations prior to being administered. Some 23% of tagged OPV was exposed for 48 hours or more to a temperature > 10 degrees C; 47.5% of tagged HB vaccines were exposed to -3 degrees C or less, the majority of them during storage in health facilities or clinics. Exposures were independent of distance from the distribution centre, mode of transport, or type of facility. Our results show that the vaccines were often exposed to temperatures outside the recommended range during transport and storage, putting them at risk of loss of potency.(ABSTRACT TRUNCATED AT 250 WORDS)
Wang, Q L; Liu, T-X
2016-12-01
Insect growth regulators (IGRs) disrupt the normal activity of the endocrine or hormone system of insects, affecting the development, reproduction, or metamorphosis of the target insects, and normally causing less detrimental effects to beneficial insects. The effects of three IGRs (pyriproxyfen, fenoxycarb, and buprofezin) on Encarsia formosa Gahan, an endoparasitoid of whiteflies, were determined using B. tabaci as a host. We assessed the effects of the IGRs on parasitoid's larval development, pupation, emergence, and contact effects of the dry residues on plant leaf and glass vial surface on adult mortality and parasitism. When the three IGRs were applied at larval stage, no or few larvae pupated in the pyriproxyfen treatments and the highest concentration of fenoxycarb, and a majority of larvae pupated in the buprofezin treatments; of those pupated, 62.3-88.1% became adults. When the IGRs were applied at the pupal stage, 2.3-17.5% developed to adults in the pyriproxyfen treatments, 59.7-89.0% in the fenoxycarb treatments, and 58.4-83.6% in the buprofezin treatments. The leaf residues of the IGRs had no appreciable effects on adults, whereas the residues on glass vial caused significantly lower adult survival than on plant leaves. The residues of pyriproxyfen and fenoxycarb slightly reduced parasitism as compared with buprofezin and controls. However, the rates of parasitoids that became adults were significantly lower, especially in the pyriproxyfen treatments. According to the standards of International Organization of Biological Control (IOBC), pyriproxyfen was harmful, while fenoxycarb and buprofezin were slightly or moderately harmful to larvae and harmless to E. formosa pupae. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Jiang, Jing; Liu, Xiaobin; Deng, Leixiu; Zhang, Peipei; Wang, Guangjun; Wang, Shifu; Liu, Honghao; Su, Yunpeng
2014-10-05
Tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) exhibits potent antitumor activity in a wide range of cancers without deleterious side effects on normal tissues. Several TRAIL derivatives have been developed to improve its pharmacokinetics and therapeutic effects through strategies such as adding a leucine zipper to increase the circulation half-life. To obtain clinical grade LZ-TRAIL for phase I clinical trial, a single batch of 30 L bioreactor culture was performed using the Escherichia coli BL21 (DE3) strain expressing the recombinant LZ-TRAIL. A robust LZ-TRAIL production fermentation process was developed, which could be scaled up from 5L to 50 L, and had a titer of approximately 1.4 g/l. A four-step purification strategy was carried out to obtain a final product with over 95% purity and 45% yield. The final material was filter sterilized, aseptically vialed, and stored at 4°C, and comprehensively characterized using multiple assays (vialed product was sterile, purity was 95%, aggregates were <5%, potency revealed IC50 of 9 nM on MDA-MB-231 cells, and the endotoxin level was <0.25 U/mg). The purity, composition, and functional activities of the molecule were confirmed. in vivo investigations indicated that LZ-TRAIL has better antitumor potency in three Xenograft tumor models compared to TRAIL (95-281). LZ-TRAIL also showed improved pharmacokinetic and safety profiles in cynomolgus monkeys without abnormalities associated with drug exposure. In conclusion, the scalable synthesis of LZ-TRAIL is useful for production of phase I clinical trial material. These preclinical investigations warrant further clinical development of this product for cancer therapy. Copyright © 2014. Published by Elsevier B.V.
Ernstgård, Lena; Lind, Birger; Andersen, Melvin E; Johanson, Gunnar
2010-01-01
Blood-air and tissue-blood coefficients (lambda) are essential to characterize the uptake and disposition of volatile substances, e.g. by physiologically based pharmacokinetic (PBPK) modelling. Highly volatile chemicals, including many hydrofluorocarbons (HFC) have low solubility in liquid media. These characteristics pose challenges for determining lambda values. A modified head-space vial equilibrium method was used to determine lambda values for five widely used HFCs. The method is based on automated head-space gas chromatography and injection of equal amount of chemical in two head-space vials with identical air phase volumes but different volumes of the liquid phase. The liquids used were water (physiological saline), fresh human blood, and olive oil. The average lambda values (n = 8) were as follows: 1,1-difluoroethane (HFC152a) - 1.08 (blood-air), 1.11 (water-air) and 5.6 (oil-air); 1,1,1-trifluoroethane (HFC143a) - 0.15, 0.15 and 1.90; 1,1,1,2-tetrafluoroethane (HFC134a) - 0.36, 0.35 and 3.5; 1,1,1,2,2-pentafluoroethane (HFC125) - 0.083, 0.074 and 1.71; and 1,1,1,3,3-pentafluoropropane (HFC245fa) - 0.62, 0.58 and 12.1. The lambda values appeared to be concentration-independent in the investigated range (2-200 ppm). In spite of the low lambda values, the method errors were modest, with coefficients of variation of 9, 11 and 10% for water, blood and oil, respectively.
Bassi, Simona; Stroppa, Elisa M.; Moroni, Carlo F.; Arbasi, Maria C.; Trabacchi, Elena; Di Franco, Anna; Lazzaro, Antonio; Bernuzzi, Patrizia; Moretto, Mauro; Arcari, Annalisa; Bosi, Costanza; Riva, Alessandra; Cavanna, Luigi; Vallisa, Daniele
2015-01-01
Background Filgrastim biosimilars have recently been introduced into clinical practice. To date biosimilars have demonstrated comparable efficacy and safety as the originator in chemotherapy-induced neutropenia. Published experience in engraftment after autologous stem cell transplantation (ASCT) is limited and concerns relatively few patients. Materials and methods With the aim of assessing the efficacy and the safety of filgrastim biosimilars in post-ASCT bone marrow recovery, we conducted a single institution, retrospective study in 56 lymphoma and myeloma patients who received filgrastim biosimilars (Tevagrastim® and Zarzio®) at standard doses from day 5. We compared our results with recently published data on the originator. A cost analysis of each biosimilar was performed. Results Neutrophil counts recovered in 55 patients. The median number of filgrastim biosimilar vials injected was seven per patient. The median time to neutrophil and platelet recovery was 10 and 12 days, respectively. Twenty-six patients had febrile neutropenia, in half of whom the agent involved was identified. In the cost analysis, the use of Tevagrastim® and Zarzio® was associated with cost reductions of 56% and of 86%, respectively. Discussion Despite differences in CD34+ cell counts and time of starting filgrastim, our results in terms of time to engraftment and median number of vials injected are similar to published data. Comparing our results by single conditioning regimen to recent literature data, the time to engraftment and duration of hospitalisation were equivalent. Significant differences were observed in the incidence of febrile neutropenia, perhaps due to different preventive and prophylactic protocols for infections. Although prospective studies should be performed to confirm our results, filgrastim biosimilars were found to be effective and safe in engraftment after ASCT. PMID:25761321
Gaillard, Laetitia; Guyon, Francois; Salagoïty, Marie-Hélène; Médina, Bernard
2013-12-01
A procedure to detect whether carbon dioxide was added to French ciders has been developed. For this purpose, an optimised and simplified method is proposed to determine (13)C/(12)C isotope ratio of carbon dioxide (δ(13)C) in ciders. Three critical steps were checked: (1) influence of atmospheric CO2 remaining in the loaded vial, (2) impact of helium flush, (3) sampling speed. This study showed that atmospheric CO2 does not impact the measurement, that helium flush can lead to isotopic fractionation and finally, that a fractionation occurs only 5h after bottle opening. The method, without any other preparation, consists in sampling 0.2 mL of cold (4 °C) cider in a vial that is passed in an ultrasonic bath for 10 min at room temperature to enhance cider de-carbonation. The headspace CO2 is then analysed using the link Multiflow®-isotope ratio mass spectrometer. Each year, a data bank is developed by fermenting authentic apples juices in order to control cider authenticity. Over a four year span (2008-2011), the CO2 produced during the fermentation step was studied. This set of 61 authentic ciders, from various French production areas, was used to determine a δ(13)C value range of -22.59±0.92‰ for authentic ciders CO2 bubbles. 75 commercial ciders were analysed with this method. Most of the samples analysed present a gas δ(13)C value in the expected range. Nevertheless, some ciders have δ(13)C values outside the 3σ limit, revealing carbonation by technical CO2. This practice is not allowed for organic, "Controlled Appellation of Origin" ciders and ciders specifying natural carbonation on the label. Copyright © 2013 Elsevier Ltd. All rights reserved.
Peterson, Michael E; Matz, Michael; Seibold, Karen; Plunkett, Signe; Johnson, Scott; Fitzgerald, Kevin
2011-08-01
To determine clinical efficacy of the Crotalidae polyvalent immune F(ab) (ovine) antivenom (OPCA) against progressive crotalid envenomation in the dog as reflected in stabilization or improvement of snakebite severity scores (SSS). Additionally, due to the potential decreased half-life of the F(ab) antibodies in dogs we compared SSS between dogs receiving 2 different dosing regimes. Prospective, clinical trial. Five veterinary emergency and critical care facilities. One hundred and fifteen client-owned Crotalid (rattlesnake) snake bitten dogs in whom worsening of the envenomation syndrome was observed before OPCA treatment. In a multicenter randomized clinical trial a single dose (1 vial) of OPCA alone was compared with 2 doses (1/2 vial each) administered 6 hours apart. Standard supportive care was provided in all cases. Data were available for 115 patients, 9 of which were fatalities. All patients' clinical condition was documented with a standardized SSS system accounting for each major body system. Each fatality received maximum severity scores of 20. The mean severity score of the 115 patients decreased from 4.19 to 3.29 points and there was no difference between the 2 treatment groups. The mean severity score of the 107 patients without fatalities decreased from 4.16 to 2.15. Antivenin-related acute reactions occurred in 6 dogs (6%), and no serum sickness occurred within the 95 cases contacted at the 2-week posttreatment follow-up. In the first randomized trial in dogs of antivenin in the United States, OPCA effectively stabilized or terminated venom effects. There were no statistical differences detected between treatment groups within the study time frame. © Veterinary Emergency and Critical Care Society 2011.
Determination of Propofol by GC/MS and Fast GC/MS-TOF in Two Cases of Poisoning.
Procaccianti, Paolo; Farè, Fiorenza; Argo, Antonella; Casagni, Eleonora; Arnoldi, Sebastiano; Facheris, Sara; Visconti, Giacomo Luca; Roda, Gabriella; Gambaro, Veniero
2017-11-01
Two cases of suspected acute and lethal intoxication caused by propofol were delivered by the judicial authority to the Department of Sciences for Health Promotion and Mother-Child Care in Palermo, Sicily. In the first case a female nurse was found in a hotel room, where she lived with her mother; four 10 mg/mL vials and two 20 mg/mL vials of propofol were found near the decedent along with syringes and needles. In the second case a male nurse was found in the operating room of a hospital, along with a used syringe. In both cases a preliminary systematic and toxicological analysis indicated the presence of propofol in the blood and urine. As a result, a method for the quantitative determination of propofol in biological fluids was optimized and validated using a liquid-liquid extraction protocol followed by GC/MS and fast GC/MS-TOF. In the first case, the concentration of propofol in blood was determined to be 8.1 μg/mL while the concentration of propofol in the second case was calculated at 1.2 μg/mL. Additionally, the tissue distribution of propofol was determined for both cases. Brain and liver concentrations of propofol were, respectively, 31.1 and 52.2 μg/g in Case 1 and 4.7 and 49.1 μg/g in Case 2. Data emerging from the autopsy findings, histopathological exams as well as the toxicological results aided in establishing that the deaths were due to poisoning, however, the manner of death in each were different: homicide in Case 1 and suicide in Case 2. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Evaluation of calcium-bearing material for treatment of CO2 leakage-induced pollution
NASA Astrophysics Data System (ADS)
Park, J.; Park, M.; Jeong, H. Y.
2017-12-01
Several Ca2+-bearing materials were evaluated for their capability to treat CO2 leakage-induced pollution for the application of permeable reactive barriers (PRBs). In this regard, a series of batch experiments were carried out with Portland cement, quick lime (CaO), and gypsum (CaSO4). Each of these materials was added to 50 mL of CO2-saturated solutions ( 7.5-8.5 mM) in serum vials sealed with Teflon-coated grey butyl stopper. Subsequently, the resultant batches were agitated at room temperature for 24 h. At predetermined intervals, each vial was sacrificed to monitor changes in pH, EC, and dissolved CO2 concentration. Despite the pH-neutralizing capacity, 0.15 g of Portland cement did not lower any dissolved CO2. When amended with 0.05 g of Ca(OH)2 or Mg(OH)2, the cement at this loading could sequester dissolved CO2, with the former being more effective. Even without such amendments, the cement at or greater than 0.2 g was shown to completely sequester dissolved CO2. In case of quick lime, its loading as low as 0.05 g instantaneously removed all dissolved CO2, which was also noted for Portland cement at 0.5 g. For gypsum, its loading at 0.12 g was not effective for immobilizing dissolved CO2. By both X-ray diffraction (XRD) and thermogravimetry (TG) analyses, the CO2 sequestration by Ca2+-bearing materials was found to be mainly due to the formation of calcite (CaCO3). Funding source: The "R&D Project on Environmental Management of Geologic CO2 Storage" from the KEITI (Project Number: 2014001810003).
Isbister, Geoffrey K; Brown, Simon G; MacDonald, Ellen; White, Julian; Currie, Bart J
2008-04-21
To investigate current use of Australian snake antivenoms and the frequency and severity of immediate-type hypersensitivity reactions. Nested prospective cohort study as part of the Australian Snakebite Project. Patients receiving snake antivenom in Australian hospitals between 1 January 2002 and 30 November 2007. The use of CSL Limited antivenom; frequency and severity of hypersensitivity reactions to antivenom; premedication and treatment of these reactions. Snake antivenom was administered to 195 patients, mostly for venom-induced consumption coagulopathy (145 patients, 74%), followed by non-specific systemic effects (12%), neurotoxicity (5%) and myotoxicity (4%). Antivenom was given to nine patients (5%) without evidence of envenoming or who were bitten by a species of snake for which antivenom is not required. The commonest antivenoms used were brown snake (46%), tiger snake (30%) and polyvalent (11%). The median dose was four vials (interquartile range, 2-5 vials), and 24 patients received two different types of antivenom. Immediate-type hypersensitivity reactions occurred in 48 patients (25%); 21 satisfied our definition of anaphylaxis, with 11 moderate and 10 severe cases, including nine in which patients were hypotensive. The remaining 27 reactions were mild (skin only). Adrenaline was used in 26 cases with good effect. The frequency of reactions to tiger snake (41%) and polyvalent (41%) antivenoms was higher than that to brown snake antivenom (10%). Hypersensitivity reactions occurred in 11 of 40 patients receiving any form of premedication (28%) and in 2 of 11 given adrenaline for premedication (18%) versus 20 of 86 not receiving premedication (23%). Antivenom was used appropriately, and most commonly for coagulopathy. Hypersensitivity reactions were common, but most were not severe. The discretionary use of premedication was not associated with any reduction in reactions.
Pietrzak-Johnston, S M; Bishop, H; Wahlquist, S; Moura, H; Da Silva, N D; Da Silva, S P; Nguyen-Dinh, P
2000-05-01
Formalin and mercuric chloride-based low-viscosity polyvinyl alcohol (LV-PVA) are widely used by most diagnostic parasitology laboratories for preservation of helminth eggs and protozoan cysts and trophozoites in fecal specimens. Concerns about the toxicity of formalin and the difficulty of disposal of LV-PVA are powerful incentives to use alternate preservatives. Such alternatives have been marketed by several companies and are often presented as one-vial, non-mercuric chloride fixatives that aim at performing the same role as formalin and PVA combined. We compared five, one-vial commercial preservatives, two from Meridian Diagnostics, Inc. (Ecofix and sodium acetate-acetic acid-formalin), and one each from Scientific Device Laboratories, Inc. (Parasafe), Alpha Tec Systems, Inc. (Proto-fix), and Streck Laboratories, Inc. (STF), with 10% formalin and LV-PVA. Fecal specimens obtained from patients in a Brazilian hospital were aliquoted within 12 h of collection into the seven preservatives mentioned above and were processed after 1 month at the Centers for Disease Control and Prevention. Direct and concentrated permanent smears as well as concentrates for 20 positive specimens (a total of 259 processed samples) were prepared, stained according to the manufacturers' instructions, examined, and graded. Positive specimens contained one or more parasites with stages consisting of eggs, larvae, cysts, and a few trophozoites of Giardia intestinalis. Criteria for assessment of the preservatives included the quality of the diagnostic characteristics of helminth eggs, protozoan cysts, and trophozoites, ease of use, and cost. Acceptable alternatives to formalin for wet preparations were found. Ecofix was found to be comparable to the traditional "gold standard" LV-PVA for the visualization of protozoa in permanent stained smears. This study suggests that more acceptable alternatives to the traditional formalin and LV-PVA exist.
Barros, Anthony; Ly, Van T; Chando, Theodore J; Ruan, Qian; Donenfeld, Scott L; Holub, David P; Christopher, Lisa J
2011-04-05
Microplate scintillation counters are utilized routinely in drug metabolism laboratories for the off-line radioanalysis of fractions collected during HPLC radioprofiling. In this process, the current fraction collection technology is limited by the number of plates that can be used per injection as well as the potential for sample loss due to dripping or spraying as the fraction collector head moves from well to well or between plates. More importantly, sample throughput is limited in the conventional process, since the collection plates must be manually exchanged after each injection. The Collect PAL, an innovative multiple-plate fraction collector, was developed to address these deficiencies and improve overall sample throughput. It employs a zero-loss design and has sub-ambient temperature control. Operation of the system is completely controlled with software and up to 24 (96- or 384-well) fraction collection plates can be loaded in a completely automated run. The system may also be configured for collection into various-sized tubes or vials. At flow rates of 0.5 or 1.0 mL/min and at collection times of 10 or 15s, the system precisely delivered 83-μL fractions (within 4.1% CV) and 250-μL fractions (within 1.4% CV), respectively, of three different mobile phases into 12 mm × 32 mm vials. Similarly, at a flow rate of 1 mL/min and 10s collection times, the system precisely dispensed mobile phase containing a [(14)C]-radiolabeled compound across an entire 96-well plate (% CV was within 5.3%). Triplicate analyses of metabolism test samples containing [(14)C]buspirone and its metabolites, derived from three different matrices (plasma, urine and bile), indicated that the Collect PAL produced radioprofiles that were reproducible and comparable to the current technology; the % CV for 9 selected peaks in the radioprofiles generated with the Collect PAL were within 9.3%. Radioprofiles generated by collecting into 96- and 384-well plates were qualitatively comparable; however, the peak resolution was greater in the profiles that were collected in 384-well plates due to the collection of a larger number of fractions per minute. In conclusion, this new and innovative fraction collector generated radioprofile results that were comparable to current technology and should provide a major improvement in capacity and throughput for radioprofiling studies. Copyright © 2010 Elsevier B.V. All rights reserved.
Abendaño, Naiara; Sevilla, Iker A; Prieto, José Miguel; Garrido, Joseba M; Juste, Ramon A; Alonso-Hearn, Marta
2013-05-03
Assessment of the virulence of isolates of Mycobacterium avium subsp. paratuberculosis (Map) exhibiting distinct genotypes and isolated from different hosts may help to clarify the degree to which clinical manifestations of the disease in cattle can be attributed to bacterial or to host factors. The objective of this study was to test the ability of 10 isolates of Map representing distinct genotypes and isolated from domestic (cattle, sheep, and goat), and wildlife animal species (fallow deer, deer, wild boar, and bison) to enter and grow in bovine macrophages. The isolates were previously typed using IS1311 PCR followed by restriction endonuclease analysis into types C, S or B. Intracellular growth of the isolates in a bovine macrophage-like cell line (BoMac) and in primary bovine monocyte-derived macrophages (MDM) was evaluated by quantification of CFU numbers in the initial inoculum and inside of the host cells at 2h and 7 d p.i. using an automatic liquid culture system (Bactec MGIT 960). Individual data illustrated that growth was less variable in BoMac than in MDM cells. All the isolates from goat and sheep hosts persisted within BoMac cells in lower CFU numbers than the other tested isolates after 7 days of infection regardless of genotype. In addition, BoMac cells exhibited differential inflammatory, apoptotic and destructive responses when infected with a bovine or an ovine isolate; which correlated with the differential survival of these strains within BoMac cells. Our results indicated that the survival of the tested Map isolates within bovine macrophages is associated with the specific host from which the isolates were initially isolated. Copyright © 2013 Elsevier B.V. All rights reserved.
... professional will: clean the skin put an elastic band (tourniquet) above the area to get the veins ... a vial or syringe take off the elastic band and remove the needle from the vein Collecting ...
Johnston, Christopher I; Ryan, Nicole M; O'Leary, Margaret A; Brown, Simon G A; Isbister, Geoffrey K
2017-02-01
Taipans (Oxyuranus spp.) are medically important venomous snakes from Australia and Papua New Guinea. The objective of this study was to describe taipan envenoming in Australian and its response to antivenom. Confirmed taipan bites were recruited from the Australian Snakebite Project. Data were collected prospectively on all snakebites, including patient demographics, bite circumstances, clinical effects, laboratory results, complications and treatment. Blood samples were taken and analysed by venom specific immunoassay to confirm snake species and measure venom concentration pre- and post-antivenom. There were 40 confirmed taipan bites: median age 41 years (2-85 years), 34 were males and 21 were snake handlers. Systemic envenoming occurred in 33 patients with neurotoxicity (26), complete venom induced consumption coagulopathy (VICC) (16), partial VICC (15), acute kidney injury (13), myotoxicity (11) and thrombocytopenia (7). Venom allergy occurred in seven patients, three of which had no evidence of envenoming and one died. Antivenom was given to 34 patients with a median initial dose of one vial (range 1-4), and a median total dose of two vials (range 1-9). A greater total antivenom dose was associated with VICC, neurotoxicity and acute kidney injury. Early antivenom administration was associated with a decreased frequency of neurotoxicity, acute kidney injury, myotoxicity and intubation. There was a shorter median time to discharge of 51 h (19-432 h) in patients given antivenom <4 h post-bite, compared to 175 h (27-1104 h) in those given antivenom >4 h. Median peak venom concentration in 25 patients with systemic envenoming and a sample available was 8.4 ng/L (1-3212 ng/L). No venom was detected in post-antivenom samples, including 20 patients given one vial initially and five patients bitten by inland taipans. Australian taipan envenoming is characterised by neurotoxicity, myotoxicity, coagulopathy, acute kidney injury and thrombocytopenia. One vial of antivenom binds all measurable venom and early antivenom was associated with a favourable outcome.
Wallace, Aaron S; Willis, Fred; Nwaze, Eric; Dieng, Boubacar; Sipilanyambe, Naawa; Daniels, Danni; Abanida, Emmanuel; Gasasira, Alex; Mahmud, Mustapha; Ryman, Tove K
2017-12-04
The introduction of new vaccines highlights concerns about high vaccine wastage, knowledge of wastage policies and quality of stock management. However, an emphasis on minimizing wastage rates may cause confusion when recommendations are also being made to reduce missed opportunities to routinely vaccinate children. This concern is most relevant for lyophilized vaccines without preservatives [e.g. measles-containing vaccine (MCV)], which can be used for a limited time once reconstituted. We sampled 54 health facilities within 11 local government areas (LGAs) in Nigeria and surveyed health sector personnel regarding routine vaccine usage and wastage-related knowledge and practices, conducted facility exit interviews with caregivers of children about missed opportunities for routine vaccination, and abstracted vaccine stock records and vaccination session data over a 6-month period to calculate wastage rates and vaccine vial usage patterns. Nearly half of facilities had incomplete vaccine stock data for calculating wastage rates. Among facilities with sufficient data, mean monthly facility-level wastage rates were between 18 and 35% across all reviewed vaccines, with little difference between lyophilized and liquid vaccines. Most (98%) vaccinators believed high wastage led to recent vaccine stockouts, yet only 55% were familiar with the multi-dose vial policy for minimizing wastage. On average, vaccinators reported that a minimum of six children must be present prior to opening a 10-dose MCV vial. Third dose of diphtheria-tetanus-pertussis vaccine (DTP3) was administered in 84% of sessions and MCV in 63%; however, the number of MCV and DTP3 doses administered were similar indicating the number of children vaccinated with DTP3 and MCV were similar despite less frequent MCV vaccination opportunities. Among caregivers, 30% reported being turned away for vaccination at least once; 53% of these children had not yet received the missed dose. Our findings show inadequate implementation of vaccine management guidelines, missed opportunities to vaccinate, and lyophilized vaccine wastage rates below expected rates. Missed opportunities for vaccination may occur due to how the health system's contradicting policies may force health workers to prioritize reduced wastage rates over vaccine administration, particularly for multi-dose vials. Published by Elsevier Ltd.
Harvey, Steven A; Incardona, Sandra; Martin, Nina; Lussiana, Cristina; Streat, Elizabeth; Dolan, Stephanie; Champouillon, Nora; Kyabayinze, Daniel J; Mugerwa, Robert; Nakanwagi, Grace; Njoki, Nancy; Rova, Ratsimandisa; Cunningham, Jane
2017-04-20
Use of antigen-detecting malaria rapid diagnostic tests (RDTs) has increased exponentially over the last decade. WHO's Global Malaria Programme, FIND, and other collaborators have established a quality assurance scheme to guide product selection, lot verification, transport, storage, and training procedures. Recent concerns over the quality of buffer packaging and test accessories suggest a need to include these items in product assessments. This paper describes quality problems with buffer and accessories encountered in a project promoting private sector RDT use in five African countries and suggests steps to avoid or more rapidly identify and resolve such problems. Private provider complaints about RDT buffer vials and kit accessories were collected during supervisory visits, and a standard assessment process was developed. Using 100 tests drawn from six different lots produced by two manufacturers, lab technicians visually assessed alcohol swab packaging, blood transfer device (BTD) usability, and buffer appearance, then calculated mean blood volume from 10 BTD transfers and mean buffer volume from 10 individual buffer vials. WHO guided complaint reporting and follow-up with manufacturers. Supervisory visits confirmed user reports of dry alcohol swabs, poorly functioning BTDs, and non-uniform volumes of buffer. Lot testing revealed further evidence of quality problems, leading one manufacturer to replace buffer vials and accessories for 40,000 RDTs. In December 2014, WHO issued an Information Notice for Users regarding variable buffer volumes in single-use vials and recommended against procurement of these products until defects were addressed. Though not necessarily comprehensive or generalizable, the findings presented here highlight the need for extending quality assessment to all malaria RDT test kit contents. Defects such as those described in this paper could reduce test accuracy and increase probability of invalid, false positive, or false negative results. Such deficiencies could undermine provider confidence in RDTs, prompting a return to presumptive treatment or reliance on poor quality microscopy. In partial response to this experience, WHO, FIND, and other project partners have developed guidance on documenting, troubleshooting, reporting, and resolving such problems when they occur.
Weant, Kyle A; Bowers, Rebecca C; Reed, Janelle; Braun, Kristopher A; Dodd, David M; Baker, Stephanie N
2012-05-01
To evaluate the safety and cost-effectiveness of a clinical protocol adopted in June 2006 that included a comprehensive, objective assessment of snake bite envenomations and standardized the use of Crotalidae polyvalent immune Fab antivenom (FabAV). Retrospective medical record review. Academic medical center that serves as the regional level I trauma center. Seventy-five adults treated with FabAV for snake envenomations in the emergency department between June 1, 2003, and June 1, 2009; 30 patients received treatment according to the protocol (treatment group), and 45 patients received treatment that did not adhere to the protocol (control group). Demographic and envenomation characteristics, as well as treatment details, were collected for all patients. In addition, information on quantity of FabAV vials required, length of hospital stay, and length of intensive care unit stay were compared between the treatment and control groups. In the treatment group, significantly fewer vials of FabAV were used (2.5 vs 4.727 vials, p=0.007). This decreased in usage correlated to a cost savings of approximately $2000/patient. Despite no significant difference in the severity of the envenomations between the two groups (p=0.379), the treatment group experienced a significantly shorter hospital length of stay (1.933 vs 2.791 days, p=0.030). No significant difference in the progression to fasciotomy or the development of allergic reactions was noted between the two groups. Use of a clinical protocol related to snake envenomations resulted in approximately two fewer vials of FabAV required for each patient. In addition, the treatment group experienced a shorter hospital length of stay without a corresponding increase in adverse events or envenomation progression. Data show that use of the protocol was cost-effective. The development of institution-specific multidisciplinary protocols regarding snake bite envenomations is recommended. Clinical pharmacists can play a vital role in the protocol development to ensure that optimal care is provided for this distinct patient population. © 2012 Pharmacotherapy Publications, Inc.
Larson, Bayli; Bushman, Lane R; Casciano, Matthew L; Oldland, Alan R; Kiser, Jennifer J; Kiser, Tyree H
2016-01-01
The primary aim of this study was to investigate ribavirin solution for inhalation stability under three different conditions (frozen, refrigerated, room temperature) over a 45-day period. A ribavirin 6000-mg vial was reconstituted with 90 mL of Sterile Water for Injection per the package insert to yield a concentration of approximately 67 mg/mL. The solution was then placed in either syringes or empty glass vials and stored in the freezer (-20°C), in the refrigerator (~0°C to 4°C), or at room temperature (~20°C to 25°C). Original concentrations were measured on day 0 and subsequent concentrations were measured on day 2, 14, and 45 utilizing a validated liquid chromatography with tandem mass spectrometry assay. All analyses were performed in triplicate for each storage condition. Additionally, at each time point the physical stability was evaluated and the pH of solution was measured. The solution was considered stable if =90% of the original concentration was retained over the study period. A validated liquid chromatography with tandem mass spectrometry analysis demonstrated that >95% of the original ribavirin concentration was preserved over the 45-day period for all study conditions. The ribavirin concentration remained within the United States Pharmacopeia (USP)-required range of 95% to 105% of the original labeled product amount throughout the entire study period for all study conditions. Precipitation of ribavirin was noted during the thawing cycle for frozen samples, but the drug went back into solution once the thawing process was completed. No changes in color or turbidity were observed in any of the prepared solutions. Values for pH remained stable over the study period and ranged from 4.1 to 5.3. Ribavirin for inhalation solution is physically and chemically stable for at least 45 days when frozen, refrigerated, or kept at room temperature after reconstitution to a concentration of approximately 67 mg/mL and placed in syringes or glass vials. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Stability of Azacitidine in Sterile Water for Injection
Walker, Scott E; Charbonneau, Lauren F; Law, Shirley; Earle, Craig
2012-01-01
Background: The product monograph for azacitidine states that once reconstituted, the drug may be held for only 30 min at room temperature or 8 h at 4°C. Standard doses result in wastage of a portion of each vial, and the cost of this wastage is significant, adding about $156 000 to annual drug expenditures at the authors’ institution. Objective: To evaluate the stability of azacitidine after reconstitution. Methods: Vials of azacitidine were reconstituted with sterile water for injection. At the time of reconstitution, the temperature of the diluent was 4°C for samples to be stored at 4°C or −20°C and room temperature for samples to be stored at 23°C. Solutions of azacitidine (10 or 25 mg/mL) were stored in polypropylene syringes and glass vials at room temperature (23°C), 4°C, or −20°C. The concentration of azacitidine was determined by a validated, stability-indicating liquid chromatographic method in serial samples over 9.6 h at room temperature, over 4 days at 4°C, and over 23 days at −20°C. The recommended expiry date was determined on the basis of time to reach 90% of the initial concentration according to the fastest observed degradation rates (i.e., lower limit of 95% confidence interval). Results: Azacitidine degradation was very sensitive to temperature but not storage container (glass vial or polypropylene syringe). Reconstitution with cold sterile water reduced degradation. At 23°C, 15% of the initial concentration was lost after 9.6 h; at 4°C, 32% was lost after 4 days; and at −20°C, less than 5% was lost after 23 days. Conclusions: More than 90% of the initial azacitidine concentration will be retained, with 97.5% confidence, if, during the life of the product, storage at 23°C does not exceed 2 h, storage at 4°C does not exceed 8 h, and storage at −20°C does not exceed 4 days. These expiry dates could substantially reduce wastage and cost where the time between doses does not exceed 4 days. PMID:23129863
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazalova, M; Ahmad, M; Fahrig, R
Purpose: To evaluate x-ray fluorescence computed tomography induced with proton beams (pXFCT) for imaging of gold contrast agent. Methods: Proton-induced x-ray fluorescence was studied by means of Monte Carlo (MC) simulations using TOPAS, a MC code based on GEANT4. First, proton-induced K-shell and L-shell fluorescence was studied as a function of proton beam energy and 1) depth in water and 2) size of contrast object. Second, pXFCT images of a 2-cm diameter cylindrical phantom with four 5- mm diameter contrast vials and of a 20-cm diameter phantom with 1-cm diameter vials were simulated. Contrast vials were filled with water andmore » water solutions with 1-5% gold per weight. Proton beam energies were varied from 70-250MeV. pXFCT sinograms were generated based on the net number of gold K-shell or L-shell x-rays determined by interpolations from the neighboring 0.5keV energy bins of spectra collected with an idealized 4π detector. pXFCT images were reconstructed with filtered-back projection, and no attenuation correction was applied. Results: Proton induced x-ray fluorescence spectra showed very low background compared to x-ray induced fluorescence. Proton induced L-shell fluorescence had a higher cross-section compared to K-shell fluorescence. Excitation of L-shell fluorescence was most efficient for low-energy protons, i.e. at the Bragg peak. K-shell fluorescence increased with increasing proton beam energy and object size. The 2% and 5% gold contrast vials were accurately reconstructed in K-shell pXFCT images of both the 2-cm and 20-cm diameter phantoms. Small phantom L-shell pXFCT image required attenuation correction and had a higher sensitivity for 70MeV protons compared to 250MeV protons. With attenuation correction, L-shell pXFCT might be a feasible option for imaging of small size (∼2cm) objects. Imaging doses for all simulations were 5-30cGy. Conclusion: Proton induced x-ray fluorescence CT promises to be an alternative quantitative imaging technique to the commonly considered XFCT imaging with x-ray beams.« less
QuantiFly: Robust Trainable Software for Automated Drosophila Egg Counting.
Waithe, Dominic; Rennert, Peter; Brostow, Gabriel; Piper, Matthew D W
2015-01-01
We report the development and testing of software called QuantiFly: an automated tool to quantify Drosophila egg laying. Many laboratories count Drosophila eggs as a marker of fitness. The existing method requires laboratory researchers to count eggs manually while looking down a microscope. This technique is both time-consuming and tedious, especially when experiments require daily counts of hundreds of vials. The basis of the QuantiFly software is an algorithm which applies and improves upon an existing advanced pattern recognition and machine-learning routine. The accuracy of the baseline algorithm is additionally increased in this study through correction of bias observed in the algorithm output. The QuantiFly software, which includes the refined algorithm, has been designed to be immediately accessible to scientists through an intuitive and responsive user-friendly graphical interface. The software is also open-source, self-contained, has no dependencies and is easily installed (https://github.com/dwaithe/quantifly). Compared to manual egg counts made from digital images, QuantiFly achieved average accuracies of 94% and 85% for eggs laid on transparent (defined) and opaque (yeast-based) fly media. Thus, the software is capable of detecting experimental differences in most experimental situations. Significantly, the advanced feature recognition capabilities of the software proved to be robust to food surface artefacts like bubbles and crevices. The user experience involves image acquisition, algorithm training by labelling a subset of eggs in images of some of the vials, followed by a batch analysis mode in which new images are automatically assessed for egg numbers. Initial training typically requires approximately 10 minutes, while subsequent image evaluation by the software is performed in just a few seconds. Given the average time per vial for manual counting is approximately 40 seconds, our software introduces a timesaving advantage for experiments starting with as few as 20 vials. We also describe an optional acrylic box to be used as a digital camera mount and to provide controlled lighting during image acquisition which will guarantee the conditions used in this study.
QuantiFly: Robust Trainable Software for Automated Drosophila Egg Counting
Waithe, Dominic; Rennert, Peter; Brostow, Gabriel; Piper, Matthew D. W.
2015-01-01
We report the development and testing of software called QuantiFly: an automated tool to quantify Drosophila egg laying. Many laboratories count Drosophila eggs as a marker of fitness. The existing method requires laboratory researchers to count eggs manually while looking down a microscope. This technique is both time-consuming and tedious, especially when experiments require daily counts of hundreds of vials. The basis of the QuantiFly software is an algorithm which applies and improves upon an existing advanced pattern recognition and machine-learning routine. The accuracy of the baseline algorithm is additionally increased in this study through correction of bias observed in the algorithm output. The QuantiFly software, which includes the refined algorithm, has been designed to be immediately accessible to scientists through an intuitive and responsive user-friendly graphical interface. The software is also open-source, self-contained, has no dependencies and is easily installed (https://github.com/dwaithe/quantifly). Compared to manual egg counts made from digital images, QuantiFly achieved average accuracies of 94% and 85% for eggs laid on transparent (defined) and opaque (yeast-based) fly media. Thus, the software is capable of detecting experimental differences in most experimental situations. Significantly, the advanced feature recognition capabilities of the software proved to be robust to food surface artefacts like bubbles and crevices. The user experience involves image acquisition, algorithm training by labelling a subset of eggs in images of some of the vials, followed by a batch analysis mode in which new images are automatically assessed for egg numbers. Initial training typically requires approximately 10 minutes, while subsequent image evaluation by the software is performed in just a few seconds. Given the average time per vial for manual counting is approximately 40 seconds, our software introduces a timesaving advantage for experiments starting with as few as 20 vials. We also describe an optional acrylic box to be used as a digital camera mount and to provide controlled lighting during image acquisition which will guarantee the conditions used in this study. PMID:25992957
Lee, Kun-Hsiung
2014-01-01
The generation of a fertile embryonic stem cell (ESC)-derived or F0 (100 % coat color chimerism) mice is the final criterion in proving that the ESC is truly pluripotent. Many methods have been developed to produce chimeric mice. To date, the most popular methods for generating chimeric embryos is well sandwich aggregation between zona pellucida (ZP) removed (denuded) 2.5-day post-coitum (dpc) embryos and ESC clumps, or direct microinjection of ESCs into the cavity (blastocoel) of 3.5-dpc blastocysts. However, due to systemic limitations and the disadvantages of conventional microinjection, aggregation, and coculturing, two novel methods (vial coculturing and hypertonic microinjection) were developed in recent years at my laboratory.Coculturing 2.5-dpc denuded embryos with ESCs in 1.7-mL vials for ~3 h generates chimeras that have significantly high levels of chimerism (including 100 % coat color chimerism) and germline transmission. This method has significantly fewer instrumental and technological limitations than existing methods, and is an efficient, simple, inexpensive, and reproducible method for "mass production" of chimeric embryos. For laboratories without a microinjection system, this is the method of choice for generating chimeric embryos. Microinjecting ESCs into a subzonal space of 2.5-dpc embryos can generate germline-transmitted chimeras including 100 % coat color chimerism. However, this method is adopted rarely due to the very small and tight space between ZP and blastomeres. Using a laser pulse or Piezo-driven instrument/device to help introduce ESCs into the subzonal space of 2.5-dpc embryos demonstrates the superior efficiency in generating ESC-derived (F0) chimeras. Unfortunately, due to the need for an expensive instrument/device and extra fine skill, not many studies have used either method. Recently, ESCs injected into the large subzonal space of 2.5-dpc embryos in an injection medium containing 0.2-0.3 M sucrose very efficiently generated viable, healthy, and fertile chimeric mice with 100 % coat color chimerism.Both vial coculture and hypertonic microinjection methods are useful and effective alternatives for producing germline chimeric or F0 mice efficiently and reliably. Furthermore, both novel methods are also good for induced pluripotent stem cells (iPSCs) to generate chimeric embryos.
Parashar, Deepak; Kabra, Sushil K; Lodha, Rakesh; Singh, Varinder; Mukherjee, Aparna; Arya, Tina; Grewal, Harleen M S; Singh, Sarman
2013-06-01
The microbiological confirmation of pulmonary tuberculosis in children relies on cultures of gastric aspirate (GA) specimens. Conventionally, GAs are neutralized to improve culture yields of mycobacteria. However, there are limited data to support this practice. To study the utility of neutralization of GAs with sodium bicarbonate in children with intrathoracic tuberculosis, a total of 116 children of either sex, aged 6 months to 14 years (median age, 120 months; interquartile range [IQR], 7 to 192 months), underwent gastric aspiration on 2 consecutive days. Gastric aspirates were divided into two aliquots, and only one aliquot was neutralized with 1% sodium bicarbonate. Both aliquots were processed for smear and culture examinations. Out of the 232 gastric aspirates, 12 (5.17%) were acid-fast bacilli (AFB) smear positive. There were no differences in smear positivity rates from samples with or without neutralization. The yield of Mycobacterium tuberculosis on a Bactec MGIT 960 culture system was significantly lower in the neutralized samples (16.3% [38/232]) than in the nonneutralized samples (21.5% [50/232]) (P = 0.023). There was no significant difference between the neutralized and the nonneutralized samples in time to detection using the MGIT 960 system (average, 24.6 days; IQR, 12 to 37 days) (P = 0.9). The contamination rates were significantly higher in the neutralized samples than in the nonneutralized samples (17.2% [40/232] versus 3.9% [9/232]) (P = 0.001). The agreement for positive mycobacterial culture between the two approaches was 66.5% (P = 0.001). Hence, we recommend that gastric aspirate samples not be neutralized with sodium bicarbonate prior to culture for M. tuberculosis.
Relationship between microbial sulfate reduction rates and sulfur isotopic fractionation
NASA Astrophysics Data System (ADS)
Matsu'Ura, F.
2009-12-01
Sulfate reduction is one of the common processes to obtain energy for certain types of microorganisms.They use hydrogen gas or organic substrates as electron donor and sulfates as electron acceptor, and reduce sulfates to sulfides. Sulfate reducing microbes extend across domains Archea and Bacteria, and are believed to be one of the earliest forms of terrestrial life (Shen 2004). The origin of 34S-depleted (light) sulfide sulfur, especially δ34S < -30 ‰, around hydrothermal vents or beneath the sea-floor is speculated to be the products of sulfate reducers. But laboratory experiments using sulfate reducers fail to produce such light sulfur, and many models were proposed to explain the discrepancy. Canfield et al. (2006) proposed so-called "standard model" based on previous studies. The standard model explained the reason for the large fractionation by temperature dependence of sulfur isotopic fractionation factor and rate of sulfate reduction, which indicated the growth conditions of microbes. However, they failed to prove their model by their other experiments (Canfield et al., 2006). In this study, I performed laboratory culture experiment of sulfate reducing bacteria (SRB) to explain the 34S-depleted sulfide sulfur. [Experiments] To compare the result with Canfield et al. (2006), I used Desulfovibrio desulfuricans for my laboratory culture experiment. D. desulfuricans was inoculated into glass vials, which contain 40ml of liquid culture media slightly modified from DSMZ #63 medium.Excess amount of Fe (II) is added to the DSMZ#63 medium to precipitate sulfide as iron sulfide. The vials were incubated at 25°C, 30°C, and 37°C, respectively. 21 vials were used for one temperature and sulfide and sulfate was collected from each three glass vials at every 12 hours from 72 hours to 144 hours after start of incubation. The sulfide was precipitated as iron sulfide and the sulfate was precipitated as barite. Sulfur isotope compositions of sulfate and sulfide were measured by standard method using Delta Plus mass-spectrometer. [Results and Discussion] The fractionation between sulfide and sulfate ranged from 2.7 to 11.0. The fractionation values varied among the different incubation temperature and growth phase of D. desulfuricans. The maximum fractionation values of three incubation temperatures were 9.9, 11.0, and 9.7, for 25 °C, 30°C, and 37°C, respectively. These results were different from standard model and Canfield et al. (2006). I could not find the clear correlation between ∂34S values and incubation temperatures in this experiment. The measured fractionation values during the incubation varied with incubation stage. The fractionation values clearly increased with incubation time at every temperature, and at 25°C ∂34S value was 3.6 at the 72h and it increased to 7.9 at 144 hours. This indicated the difference of sulfate reduction rate due to the growth phase of SRB. In the early logarithmic growth phase, metabolic activity of SRB is high and sulfate reduction rate is fast. In contrast at the stationary phase, SRB stop growing and sulfate reduction rate get slower. My result suggested that the sulfur isotopic fractionation is controlled by growth phase of SRB and lighter sulfide would be produced by the stationary phase or half-dormant SRB in natural environment.
... Avian Swine Variant Pandemic Other Thimerosal in Flu Vaccine Questions & Answers Language: English (US) Español Recommend on ... or fungi from contaminating the vaccine. Do flu vaccines contain thimerosal? Flu vaccines in multi-dose vials ...
Robot-assisted preparation of oncology drugs: the role of nurses.
Palma, Elisabetta; Bufarini, Celestino
2012-12-15
Since 2007, the preparation of cancer drugs at the Pharmacy of the University Hospital of Ancona has been progressively robotized. Currently, the process of preparation of intravenous cancer drugs is almost totally automated (95%). At present, the Cytotoxic laboratory of Ancona is the sole, in Europe, that can count on two robots. The robots handle 56 oncology molecules, which correspond to more than 160 different vials. The production rate in 2011 exceeded 19,000 preparations. The quality of compounding and the sterility controls are satisfactory, every step of the process is traceable. The nursing staff played a fundamental role in the robot development process. The nursing staff and the pharmacists are still collaborating with the robotic engineers in order to increase efficiency, ergonomics and user-friendliness of the robots. Copyright © 2012 Elsevier B.V. All rights reserved.
Development of binding assays in microfabricated picoliter vials: an assay for biotin.
Grosvenor, A L; Feltus, A; Conover, R C; Daunert, S; Anderson, K W
2000-06-01
A homogeneous binding assay for the detection of biotin in picoliter vials was developed using the photoprotein aequorin as the label. The binding assay was based on the competition of free biotin with biotinylated aequorin (AEQ-biotin) for avidin. A sequential protocol was used, and modification of the assay to reduce the number of steps was examined. Results showed that detection limits on the order of 10(-14) mol of biotin were possible. Reducing the number of steps provided similar detection limits but only if the amount of avidin used was decreased. These binding assays based on picoliter volumes have potential applications in a variety of fields, including microanalysis and single-cell analysis, where the amount of sample is limited. In addition, these assays are suitable for the high-throughput screening of biopharmaceuticals.
NASA Technical Reports Server (NTRS)
Zemcov, Michael; Cardona, Pedro; Parkus, James; Patru, Dorin; Yost, Valerie
2017-01-01
Power generation in extreme environments, such as the outer solar system, the night side of planets, or other low-illumination environments, currently presents a technology gap that challenges NASA's ambitious scientific goals. We are developing a radioisotope power cell (RPC) that utilizes commercially available tritium light sources and standard 1.85 eV InGaP2 photovoltaic cells to convert beta particle energy to electric energy. In the test program described here, we perform environmental tests on commercially available borosilicate glass vials internally coated with a ZnS luminescent phosphor that are designed to contain gaseous tritium in our proposed power source. Such testing is necessary to ensure that the glass containing the radioactive tritium is capable of withstanding the extreme environments of launch and space for extended periods of time.
False no-growth blood cultures in pneumococcal pneumonia.
Adeniyi-Jones, C C; Stevens, D L; Rasquinha, E S
1980-01-01
The growth of Streptococcus pneumoniae in commercial media containing 14C-labeled substrates was studied experimentally; the results of blood cultures that were positive for S. pneumoniae over a 14-month period were analyzed to explain no-growth but radiometrically positive blood cultures from four patients with clinically diagnosed pneumococcal pneumonia. The growth of S. pneumonoiae in aerobic blood culture vials resulted in a chocolate color in the medium. S. pneumoniae grew rapidly in both aerobic and anaerobic media, but 14CO2 evolved from the metabolism of the labeled substrates was detected only in the aerobic culture vials. Radiometric detection lagged behind growth of the organisms and was accompanied by visual changes in the media. By 24 h, the viability of the culture was on the decline; radiometric readings remained positive even when the culture had died. PMID:7419708
Automated diagnostic kiosk for diagnosing diseases
Regan, John Frederick; Birch, James Michael
2014-02-11
An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.
Bhilwar, Meenakshi; Lal, Panna
2017-07-01
Vaccine vial monitor (VVM) is now commonly used for vaccines that are included in the National Immunization Schedule in India. It helps to indicate the viability of the vaccine and of the proper functioning of the cold chain. This is useful as it prevents health personnel from administering damaged vaccine. Studies have shown a lack of awareness of health workers regarding the use and interpretation of a VVM. The current study, undertaken among the caregivers of children who were immunized, showed that this lack of information about the VVM also exists among the caregivers. This deficiency in knowledge, both in the health workers and the caregivers, can affect the health of the child and needs urgent attention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parthipun, A. A., E-mail: aneeta@hotmail.co.uk; Taylor, J.; Manyonda, I.
The purpose of this study was to determine whether there is a correlation between large uterine fibroid diameter, uterine volume, number of vials of embolic agent used and risk of complications from uterine artery embolisation (UAE). This was a prospective study involving 121 patients undergoing UAE embolisation for symptomatic uterine fibroids at a single institution. Patients were grouped according to diameter of largest fibroid and uterine volume. Results were also stratified according to the number of vials of embolic agent used and rate of complications. No statistical difference in complication rate was demonstrated between the two groups according to diametermore » of the largest fibroid (large fibroids were classified as {>=}10 cm; Fisher's exact test P = 1.00), and no statistical difference in complication rate was demonstrated according to uterine volume (large uterine volume was defined as {>=}750 cm{sup 3}; Fisher's exact test P = 0.70). 84 of the 121 patients had documentation of the number of vials used during the procedure. Patients were divided into two groups, with {>=}4 used defined as a large number of embolic agent. There was no statistical difference between these two groups and no associated increased risk of developing complications. This study showed no increased incidence of complications in women with large-diameter fibroids or uterine volumes as defined. In addition, there was no evidence of increased complications according to quantity of embolic material used. Therefore, UAE should be offered to women with large fibroids and uterine volumes.« less
Gómez-Álvarez, Sandra; Porta-Oltra, Begoña; Hernandez-Griso, Marta; Pérez-Labaña, Francisca; Climente-Martí, Mónica
2016-01-01
to assess the impact of two closed-system drug transfer device on the local and environmental contamination and preparation times in the process of preparation of parenteral chemotherapy compared to the standard system. prospective observational study. Two different closed- systems providers, Care Fusion® and Icu Medical®, were compared to standard preparation. 15 nurses of Pharmacy Department prepared 5 preparations each one, one with the standard procedure and four using closed-systems. To evaluate the contamination, a fluorescein solution 0.5% was prepared. Two kind of contamination were evaluated, local (three points connection: closed-system connect vial, syringe and final infusion bags) and environmental (gloves and countertop). Percentage of contaminated preparations was obtained in each one. Time taken by each nurse in each preparation was recorded. 75 preparations were prepared. Local contamination was reduced 21% and 75% in closed-system Icu Medical® and Care Fusion® respectively. Care Fusion® closed system, local contamination was significantly lower than the standard system to the vial, syringe and final package, while Icu Medical® closed-systems only was significantly lower in the connection to the vial. Time of preparation was increased significantly with the use of closed-system between 23.4 and 30.5 seconds. both closed-systems drug transfer device have shown an improvement in contamination than the use of the standard system. However, preparation time has been significantly increased with the use of both systems. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Kristensen, Debra D; Bartholomew, Kate; Villadiego, Shirley; Lorenson, Kristina
2016-12-07
This study attempts to capture the opinions of stakeholders working in immunization programs in low- and middle-income countries to understand how vaccine products could be improved to better meet their needs and to obtain feedback on specific vaccine product attributes including the number of doses per container and ease of preparing a dose for administration. We also reviewed how procurement decisions are made within immunization programs. Semi-structured interviews were undertaken with 158 immunization stakeholders in Brazil, China, India, Peru, the Philippines, and Tanzania. Interviewees included national decision-makers and advisors involved in vaccine-purchasing decisions (n=30), national Expanded Programme on Immunization managers (n=6), and health and logistics personnel at national, subnational, and health-facility levels (n=122). Immunization stakeholders at all levels of the supply chain valued vaccine product attributes that prevent heat damage, decrease vaccine wastage, and simplify delivery. Minimizing the time required to prepare a dose is especially valued by those closest to the work of actually administering vaccines. Respondents appreciated the benefits of lower-multidose presentations on reducing wastage but seemed to prefer single-dose vials even more. They also expressed concern about the need for training and the potential for confusion and vial contamination if opened vials of liquid preservative-free vaccines are not handled properly. Procurement decision-making processes varied widely between countries, though most relied heavily on international agencies and vaccine manufacturers for information. Copyright © 2016. Published by Elsevier Ltd.
Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R
2016-05-01
This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.
Platek, S Frank; Keisler, Mark A; Ranieri, Nicola; Reynolds, Todd W; Crowe, John B
2002-09-01
The ability to accurately determine the number of syringe needle penetration holes through the rubber stoppers in pharmaceutical vials and rubber septa in intravenous (i.v.) line and bag ports has been a critical factor in a number of forensic cases involving the thefts of controlled substances or suspected homicide by lethal injection. In the early 1990s, the microscopy and microanalysis group of the U.S. Food and Drug Administration's Forensic Chemistry Center (FCC) developed and implemented a method (unpublished) to locate needle punctures in rubber pharmaceutical vial stoppers. In 1996, as part of a multiple homicide investigation, the Indiana State Police Laboratory (ISPL) contacted the FCC for information on a method to identify and count syringe needle punctures through rubber stoppers in pharmaceutical vials. In a joint project and investigation using the FCC's needle hole location method and applying a method of puncture site mapping developed by the ISPL, a systematic method was developed to locate, identify, count, and map syringe punctures in rubber bottle stoppers or i.v. bag ports using microscopic analysis. The method requires documentation of punctures on both sides of the rubber stoppers and microscopic analysis of each suspect puncture site. The final result of an analysis using the method is a detailed diagram of puncture holes on both sides of a questioned stopper and a record of the minimum number of puncture holes through a stopper.
White, Jessica A; Estrada, Marcus; Weldon, William C; Chumakov, Konstantin; Kouiavskaia, Diana; Fournier-Caruana, Jacqueline; Stevens, Eric; Gary, Howard E; Maes, Edmond F; Oberste, M Steven; Snider, Cynthia J; Anand, Abhijeet; Chen, Dexiang
2018-05-01
According to manufacturers, inactivated poliovirus vaccines (IPVs) are freeze sensitive and require storage between 2°C and 8°C, whereas oral poliovirus vaccine requires storage at -20 °C. Introducing IPV into ongoing immunization services might result in accidental exposure to freezing temperatures and potential loss of vaccine potency. To better understand the effect of freezing IPVs, samples of single-dose vaccine vials from Statens Serum Institut (VeroPol) and multi-dose vaccine vials from Sanofi Pasteur (IPOL) were exposed to freezing temperatures mimicking what a vaccine vial might encounter in the field. D-antigen content was measured to determine the in vitro potency by ELISA. Immunogenicity testing was conducted for a subset of exposed IPVs using the rat model. Freezing VeroPol had no detectable effect on in vitro potency (D-antigen content) in all exposures tested. Freezing of the IPOL vaccine for 7 days at -20 °C showed statistically significant decreases in D-antigen content by ELISA in poliovirus type 1 (p < 0.0001) and type 3 (p = 0.048). Reduction of poliovirus type 2 potency also approached significance (p = 0.062). The observed loss in D-antigen content did not affect immunogenicity in the rat model. Further work is required to determine the significance of the loss observed and the implications for vaccine handling policies and practices. Copyright © 2018. Published by Elsevier Ltd.
DenHerder, Johnathan M; Reed, Ralph L; Sargent, Jennifer L; Bobe, Gerd; Stevens, Jan F; Diggs, Helen E
2017-01-01
Buprenorphine is a partial μ-opioid agonist used for analgesia. Due to the small size of laboratory rodents, buprenorphine HCl is typically diluted 10- or 20-fold with a sterile diluent, such as saline, for accurate dosing. Protocols for preparing and storing diluted buprenorphine vary by institution, and little published information is available regarding stability and beyond-use dating of specific buprenorphine preparations. The purpose of this study was to determine the chemical and microbiologic stability of diluted buprenorphine stored for a maximum of 180 d. Buprenorphine HCl was diluted 1:10 into sterile bacteriostatic saline by using aseptic technique. Diluted samples were stored in glass vials or plastic syringes, protected from light, and maintained at refrigerated or room temperature for as long as 180 d. Aerobic and anaerobic cultures on all stored samples were negative for bacterial and fungal growth. According to HPLC analysis, diluted buprenorphine stored in glass vials experienced less than 10% loss when stored for 180 d at either refrigerated or room temperature. However, the concentration of buprenorphine stored in syringes declined rapidly to more than 80% loss at room temperature and 28% loss in the refrigerator after 180 d. According to the results of this study, diluted buprenorphine stored in glass vials retains more than 90% of the initial concentration and is microbiologically stable for 180 d. However, our data suggest that, regardless of the duration, storing diluted buprenorphine in plastic syringes is inadvisable. PMID:28724496
Aluminizing a Ni sheet through severe plastic deformation induced by ball collisions
NASA Astrophysics Data System (ADS)
Romankov, S.; Shchetinin, I. V.; Park, Y. C.
2015-07-01
Aluminizing a Ni sheet was performed through severe plastic deformation induced by ball collisions. The Ni sheet was fixed in the center of a mechanically vibrated vial between two connected parts. The balls were loaded into the vial on both sides of the Ni disk. Al disks, which were fixed on the top and the bottom of the vial, served as the sources of Al contamination. During processing, the Ni sheet was subject to intense ball collisions. The Al fragments were transferred and alloyed to the surface of the Ni sheet by these collisions. The combined effects of deformation-induced plastic flow, mechanical intermixing, and grain refinement resulted in the formation of a dense, continuous nanostructured Al layer on the Ni surface on both sides of the sheet. The Al layer consisted of Al grains with an average size of about 40 nm. The Al layer was reinforced with nano-sized Ni flakes that were introduced from the Ni surface during processing. The local amorphization at the Ni/Al interface revealed that the bonding between Ni and Al was formed by mechanical intermixing of atomic layers at the interface. The hardness of the fabricated Al layer was 10 times that of the initial Al plate. The ball collisions destroyed the initial rolling texture of the Ni sheet and induced the formation of the mixed [1 0 0] + [1 1 1] fiber texture. The laminar rolling structure of the Ni was transformed into an ultrafine grain structure.
Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bellini, G.; Benziger, J.; Bick, D.
2013-07-01
We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) \\mu s and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties andmore » are compatible with previous measurements.« less
Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N
2005-01-01
Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation) may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures. PMID:15667662
Preparation and Characterization of a Superparamagnetic Polymer Nanocomposite
NASA Astrophysics Data System (ADS)
Brenner, N.; Isseroff, R.; Rafailovich, M.; Rudomen, G.; Gambino, R.; Liang, S. S.; Sunil, D.; Si, M.; Collazo, L.; Pernodet, N.; Fang, X.
2006-03-01
Fe(CO)5 decomposition produced ferro- and superparamagnetic polymer nanocomposites. Fe(CO)5 and Cloisite 20A clay were combined in a closed vial for 12 hours, then opened to air for 2 hours. Mössbauer analysis indicated formation of Fe2O3 on clay; mass analysis indicated 12% Fe in clay. A Brabender mixed Fe2O3/clays with PMMA and EVA at ratios by mass of 9:4:36 and 1:1:4 respectively (Fe(CO)5:clay:polymer). TEM displayed Fe2O3 nanoparticles, 3.3 ^+ 0.8 nm in diameter, adsorbed on exfoliated clay platelet surfaces in polymer matrices. VSM data indicated superparamagnetism with moments of 510.3 emu/g(Fe2O3) (PMMA) and 8.46 emu/g(Fe2O3) (EVA). DMA showed 37% decreased dynamic modulus (EVA) and 11% (PMMA) due to Fe2O3. TGA indicated PMMA stability to 400^oC (9.3% mass residual) and EVA to 435^oC (11% mass residual). Cell adhesion tests showed Fe2O3/clay enhanced proliferation, promising applications in bone implants.
Novel multipurpose timer for laboratories
NASA Technical Reports Server (NTRS)
Eisler, W. J.; Klein, P. D.
1969-01-01
Multipurpose digital delay timer simultaneously controls both a buffer pump and a fraction-collector. Timing and control may be in 30-second increments for up to 15 hours. Use of glassware and scintillation vials make it economical.
Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela
2016-05-24
To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution. Comparar a esterilidade e a carga microbiana (bactérias e fungos) da parte externa dos frascos de envasamento de bupivacaína hiperbárica (Neocaína®) em ampola e bupivacaína em frasco-ampola das apresentações convencional e estéril (sterile pack). As apresentações estéreis (sterile pack) foram distribuídas em dois grupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (p<0,001). O microbiano mais comum nas amostras convencionais foi o Staphylococcus aureus. Não houve crescimento de fungos em nenhum dos grupos. O uso de embalagens estéreis (sterile pack) diminui a carga microbiana dos frascos de envasamentos, o que diminuiria a chance de exposição a uma potencial contaminação da solução anestésica.
The Greenhouse Effect in a Vial.
ERIC Educational Resources Information Center
Golden, Richard; Sneider, Cary
1989-01-01
Presents an example of a greenhouse-effect experiment from the Climate Protection Institute. Analyzes the amount of carbon dioxide in ambient air, human exhalation, automobile exhaust, and nearly pure carbon dioxide by titrating with ammonia and bromthymol blue. (MVL)
Analysis for drugs in saliva and breath
DOT National Transportation Integrated Search
1981-09-25
Collection devices for saliva and breath that involved non-invasive techniques for sample collection were evaluated. Having subjects simply spit into a specially prepared glass vial was found to be an efficient, inexpensive and simple way to collect ...
Analysis for drug in saliva and breath
DOT National Transportation Integrated Search
1981-09-25
Collection devices for saliva and breath that involved non-invasive : techniques for sample collection were evaluated. Having subjects simply : spit into a specially prepared glass vial was found to be an efficient, : inexpensive and simple way to co...