Sample records for bactec system compared

  1. Comparison of the recovery of Mycobacterium bovis isolates using the BACTEC MGIT 960 system, BACTEC 460 system, and Middlebrook 7H10 and 7H11 solid media.

    PubMed

    Hines, Nichole; Payeur, Janet B; Hoffman, Lorraine J

    2006-05-01

    The BACTEC Microbacteria Growth Indicator Tube (MGIT) 960 system was evaluated to determine how it compares with the BACTEC 460 radiometric system and solid media for recovery of Mycobacterium bovis from tissue samples. A total of 506 bovine lymph node samples were collected from abattoirs in the United States and Mexico between November 2003 and September 2004. Processed samples were inoculated into an MGIT 960 tube, BACTEC 460 vial, and Middlebrook 7H10 and Middlebrook 7H11 solid media. Ziehl-Neelsen slides were prepared to check for contaminants and confirm the presence of acid-fast positive bacilli. Samples containing acid-fast bacilli were confirmed as members of the Mycobacterium tuberculosis complex by a nucleic acid assay. Niacin and nitrate biochemical tests were used to distinguish M. bovis from M. tuberculosis isolates. Statistical analyses were performed to compare recovery rate, mean time to detection, contamination rates, as well as pair-wise comparisons in each category. The results showed that the MGIT 960 system had a higher recovery rate of M. bovis (122/129) than did the BACTEC 460 (102/129) and solid media system (96/129). The average time to detection was 15.8 days for the MGIT 960 system, 28.2 days for the BACTEC 460 system, and 43.4 days for solid media. Contamination rates were 6.9% for the MGIT 960 system, 3.4% for the BACTEC 460 system, and 21.7% for solid media. These results indicate the MGIT 960 system can be used as an alternative to the BACTEC 460 system for recovering M. bovis from tissue samples.

  2. An appropriately performed conventional blood culture can facilitate choice of therapy in resource-constrained settings-comparison with BACTEC 9050.

    PubMed

    Surase, P V; Nataraj, G; Pattamadai, K; Mehta, P R; Pazare, A R; Agarwal, M C; Nanavati, R N

    2016-01-01

    Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. A prospective study was carried out in a multispecialty tertiary care teaching hospital. A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.

  3. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinstein, M.P.; Mirrett, S.; Reller, L.B.

    1988-05-01

    The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilusmore » species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi.« less

  4. Evaluation of the HB&L System for the Microbiological Screening of Storage Medium for Organ-Cultured Corneas.

    PubMed

    Camposampiero, D; Grandesso, S; Zanetti, E; Mazzucato, S; Solinas, M; Parekh, M; Frigo, A C; Gion, M; Ponzin, D

    2013-01-01

    Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were performed (a) after six days of storage, (b) end of storage, and (c) after 24 hours of preservation in deturgescent liquid sequentially. 10,655 storage and deturgescent media samples were subjected to microbiological control using BACTEC (6-day incubation) and HB&L (24-hour incubation) systems simultaneously. BACTEC positive/negative refers to both/either aerobic and anaerobic positives/negatives, whereas HB&L can only detect the aerobic microbes, and therefore the positives/negatives depend on the presence/absence of aerobic microorganisms. Results. 147 (1.38%) samples were identified positive with at least one of the two methods. 127 samples (134 identified microorganisms) were positive with both HB&L and BACTEC. 14 HB&L+/BACTEC- and 6 BACTEC+/HB&L- were identified. Sensitivity (95.5%), specificity (99.8%), and positive (90.1%) and negative predictive values (99.9%) were high with HB&L considering a 3.5% annual contamination rate. Conclusion. HB&L is a rapid system for detecting microorganisms in corneal storage medium in addition to the existing methods.

  5. Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems.

    PubMed

    Somily, Ali Mohammed; Habib, Hanan Ahmed; Torchyan, Armen Albert; Sayyed, Samina B; Absar, Muhammed; Al-Aqeel, Rima; Binkhamis, A Khalifa

    2018-01-01

    Bloodstream infections are associated with high rates of morbidity and mortality. Rapid detection of bloodstream infections is important in achieving better patient outcomes. Compare the time-to-detection (TTD) of the new BacT/Alert Virtuo and the BACTEC FX automated blood culture systems. Prospective simulated comparison of two instruments using seeded samples. Medical microbiology laboratory. Blood culture bottles were seeded in triplicate with each of the standard ATCC strains of aerobes, anaerobes and yeast. TTD was calculated as the length of time from the beginning of culture incubation to the detection of bacterial growth. TTD for the various tested organisms on the two microbial detection systems. The 99 bottles of seeded blood cultures incubated in each of the blood culture systems included 21 anaerobic, 39 aerobic and 39 pediatric bottles. The BacT/Alert Virtuo system exhibited significantly shorter TTD for 72.7 % of the tested organisms compared to BACTEC FX system with a median difference in mean TTD of 2.1 hours (interquartile range: 1.5-3.5 hours). The BACTEC FX system was faster in 15.2% (5/33) of microorganisms, with a median difference in mean TTD of 25.9 hours (IQR: 9.1-29.2 hours). TTD was significantly shorter for most of the microorganisms tested on the new BacT/Alert Virtuo system compared to the BACTEC FX system. Use of simulated cultures to assess TTD may not precisely represent clinical blood cultures. None.

  6. Efficacy of BACTEC TB in the rapid confirmatory diagnosis of mycobacterial infections. A Lebanese tertiary care center experience.

    PubMed

    Itani, Lina Y; Cherry, Mohamad A; Araj, George F

    2005-01-01

    Rapid detection of Mycobacterium tuberculosis (MTB), especially multidrug-resistant strains, is of importance for prompt clinical management and initiation of public health control measures. Culture remains the "gold" standard in the confirmatory laboratory diagnosis of mycobacterial infections. The reliability of the automated radiometric BACTEC 460 TB (BACTEC) system for the rapid detection of mycobacteria in clinical specimens was evaluated and compared to the conventional culture on Lowenstein-Jensen (LJ) medium. All clinical specimens submitted for mycobacterial culture were processed and simultaneously cultured on both BACTEC broth medium and LJ solid medium. Acid-fast bacilli (AFB) smears were also performed on the sediments. Differentiation of mycobacterial isolates as MTB or Mycobacterium sp. other than tuberculosis (MOTT) was based on the BACTEC NAP test. All positive culture findings recovered between January 1997 and December 2003 were analyzed in this study. A total of 3300 specimens were tested of which 355 (10.7%) yielded positive cultures consisting of 233 (65.6%) MTB and 122 (34.4%) MOTT. The percentages of AFB smear-positive were 45% and 49% in clinical specimens yielding MTB & MOTT, respectively. Though several types of specimens were cultured, most isolates (72% of MTB & 91% of MOTT) were recovered from respiratory specimens. Overall, the BACTEC showed significantly higher mycobacteria recovery rate (91%) than LJ (77%). In terms of times to detection, BACTEC showed significantly shorter detection time of isolates than LJ for the overall (mean 9.6 days for BACTEC vs. 22.8 days for LJ) and for each category of AFB smear finding. The detection time is shortened for BACTEC with the increasing grade of smear positivity. BACTEC is substantially more sensitive, efficient and rapid than LJ in the laboratory diagnosis of mycobacterial infections. This system also provides rapid differentiation of MTB from MOTT and susceptibility test results on MTB. However, the simultaneous use of BACTEC and LJ is recommended to provide maximum optimal recovery of isolates from clinical specimens. The time-saving in BACTEC provides an excellent facility for physicians in patient management and to public health personnel for prompt initiation of infection control measures.

  7. Evaluation of BACTEC 9240 blood culture system by using high-volume aerobic resin media.

    PubMed Central

    Schwabe, L D; Thomson, R B; Flint, K K; Koontz, F P

    1995-01-01

    The BACTEC 9240 blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is one of three automated, continuous-monitoring systems that is widely used in clinical laboratories. The BACTEC 9240 was compared with the BACTEC NR 660 for the detection of organisms and bacteremic episodes; time to detection of positive cultures; number of false-positive and false-negative cultures; and time needed to load, process, and perform quality control functions by using high-volume aerobic media. Blood specimens (5,282) were inoculated in equal volumes (5 to 10 ml per bottle) into BACTEC Plus Aerobic/F (9240 system) and BACTEC Plus NR26 (660 system) bottles. Clinically significant isolates were detected in 6.6% of cultures, representing 348 microorganisms and 216 bacteremic episodes. Two hundred forty-eight microorganisms were detected by both systems, 48 by the 9240 only and 52 by the 660 only (P = not significant). Of the bacteremic episodes, 158 were detected by both systems, 27 by the 9240 only and 31 by the 660 only (P = not significant). Analysis of data by month revealed equivalent recovery rates for both systems, with the exception of a 30-day period at one study site during which the 660 system detected significantly more microorganisms. Following a proprietary hardware design retrofit of the 9240 instrument, detection rates were again equivalent for the remaining three months at this study site. Positive cultures detected by both systems were detected an average of 4.3 h faster by the 9240 system (21 versus 25.3 h). The numbers of false-positive cultures for the 9240 and 660 systems were 40 (1.0%) and 9 ( < 1.0%), respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7494044

  8. Syndrome Evaluation System (SES) versus Blood Culture (BACTEC) in the Diagnosis and Management of Neonatal Sepsis--A Randomized Controlled Trial.

    PubMed

    Bhat, B Vishnu; Prasad, P; Ravi Kumar, Venkata Banda; Harish, B N; Krishnakumari, K; Rekha, Anand; Manjunath, G; Adhisivam, B; Shruthi, B

    2016-05-01

    To compare the clinical outcome of a multiplex polymerase chain reaction (PCR) based molecular diagnostic method -- Syndrome Evaluation System (SES) directed treatment strategy vs. standard of care (blood culture) directed treatment strategy for neonatal sepsis. This randomized controlled trial (RCT) included 385 neonates with sepsis who were randomized into two groups -- SES and control (BACTEC). Both tests were performed for all the neonates. However, in the SES group, the results of SES test were revealed to the treating clinicians, while in the control group, SES results were withheld. Two ml of blood was drawn from each baby. One aliquot was sent for blood culture, whereas the remaining aliquot was sent for SES. Babies were then administered empirical IV antibiotics and given supportive care. Further antibiotic changes, if required were done in SES and control groups based on their respective reports. The microbiological profile, immediate outcome, duration of hospital stay, number of antibiotics used and readmission within a month in both groups were compared. SES was better than BACTEC in identifying the causative organism in both the groups (68 % vs. 18 % in SES group and 72 % vs. 18 % in control group). SES had 100 % concordance with blood culture by BACTEC. Detection of bacteria and fungi were four and ten-fold higher respectively with SES when compared to BACTEC culture. Microbiological diagnosis was rapid with SES compared to BACTEC (7 h vs. 72 h). Treatment based on SES resulted in significantly less mortality (3 % vs. 18 %). Readmission rate, duration of hospital stay and change in antibiotics were also significantly less in SES group. This new molecular based diagnostic system (SES) helps in rapid and accurate diagnosis of neonatal sepsis and reduces mortality and morbidity in affected neonates.

  9. Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brannon, P.; Kiehn, T.E.

    1985-12-01

    The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours and Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, weremore » detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures.« less

  10. Performance of Two Resin-Containing Blood Culture Media in Detection of Bloodstream Infections and in Direct Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry (MALDI-TOF MS) Broth Assays for Isolate Identification: Clinical Comparison of the BacT/Alert Plus and Bactec Plus Systems

    PubMed Central

    Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Spanu, Teresa

    2014-01-01

    We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization–time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. PMID:25031441

  11. Use of amplified Mycobacterium tuberculosis direct test in respiratory samples from HIV-infected patients in Brazil.

    PubMed

    Barreto, Leonardo Bruno Paz Ferreira; Lourenço, Maria Cristina da Silva; Rolla, Valéria Cavalcanti; Veloso, Valdiléia Gonçalves; Huf, Gisele

    2014-01-01

    To compare the accuracy of the amplified Mycobacterium tuberculosis direct (AMTD) test with reference methods for the laboratory diagnosis of tuberculosis in HIV-infected patients. This was a study of diagnostic accuracy comparing AMTD test results with those obtained by culture on Löwenstein-Jensen (LJ) medium and by the BACTEC Mycobacteria Growth Indicator Tube 960 (BACTEC MGIT 960) system in respiratory samples analyzed at the Bioassay and Bacteriology Laboratory of the Oswaldo Cruz Foundation Evandro Chagas Clinical Research Institute in the city of Rio de Janeiro, Brazil. We analyzed respiratory samples collected from 118 patients, of whom 88 (74.4%) were male. The mean age was 36.6 ± 10.6 years. Using the AMTD test, the BACTEC MGIT 960 system, and LJ culture, we identified M. tuberculosis complex in 31.0%, 29.7%, and 27.1% of the samples, respectively. In comparison with LJ culture, the AMTD test had a sensitivity, specificity, positive predictive value, and negative predictive value of 87.5%, 89.4%, 75.7%, and 95.0%, respectively, for LJ culture, whereas, in comparison with the BACTEC MGIT 960 system, it showed values of 88.6%, 92.4%, 83.8%, and 94.8%, respectively. The AMTD test showed good sensitivity and specificity in the population studied, enabling the laboratory detection of M. tuberculosis complex in paucibacillary respiratory specimens.

  12. Comparison of Mycobacterium tuberculosis culture using liquid culture medium and Lowenstein Jensen medium in abdominal tuberculosis.

    PubMed

    Shah, Sudeep R; Shenai, Shubhada; Desai, Devendra C; Joshi, Anand; Abraham, Philip; Rodrigues, Camilla

    2010-11-01

    Traditionally, the Lowenstein Jensen (LJ) medium has been used for culturing Mycobacterium tuberculosis. In abdominal tuberculosis (TB), the reported yield from tissue culture is between 20% and 60%. Liquid cultures are reported to give a higher yield but there is little data available in abdominal TB. To compare the yield of TB culture with BACTEC 460TB liquid medium and LJ medium for patients with suspected abdominal TB and determine cost effectiveness. This prospective study was done in consecutive cases with clinical, radiological, endoscopic/surgical, and histological suspicion of abdominal TB. Tissue biopsies obtained at colonoscopy or surgery were processed and plated on LJ medium as well as the BACTEC 460TB system. NAP (ρ-nitro-α-acetylamino-β-hydroxy-propiophenone) differentiation was carried out to determine species. The cost of each method and cost per yield were calculated. Of the 29 cases, 22 cases (76%) were positive on BACTEC 460TB culture while 14 (48%) were positive on LJ medium giving a 64% increment in yield. However, the culture of one patient grew on LJ medium, where the BACTEC 460TB was negative. The additional cost of BACTEC 460TB is Rs. 460 and LJ is Rs. 40. Samples from patients with abdominal TB should be processed on both liquid and LJ medium. For high yield, the use of a liquid culture medium system is essential.

  13. Performance of two resin-containing blood culture media in detection of bloodstream infections and in direct matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) broth assays for isolate identification: clinical comparison of the BacT/Alert Plus and Bactec Plus systems.

    PubMed

    Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Sanguinetti, Maurizio; Spanu, Teresa

    2014-10-01

    We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥ 16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤ 5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization-time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  14. Diagnosis of brucellosis by using blood cultures.

    PubMed Central

    Ruiz, J; Lorente, I; Pérez, J; Simarro, E; Martínez-Campos, L

    1997-01-01

    The performances of three blood culture systems, Hemoline performance diphasic medium (bioMérieux, Marcy l'Etoile, France), Bactec Plus Aerobic/F* (Becton Dickinson, Paramus, N.J.), and Vital Aer (bioMérieux), were compared for the diagnosis of 17 cases of brucellosis. By using a 5-day incubation protocol, positive results were 52.9, 82.4, and 11.8%, respectively. When the protocol was extended to 7 days, the results were 76.5, 94.1, and 47.1%, respectively. Bactec was the fastest system (P < 0.05). PMID:9276429

  15. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinstein, M.P.; Mirrett, S.; Reimer, L.G.

    1989-03-01

    In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield ofmore » streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory.« less

  16. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS

    PubMed Central

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS. PMID:26554930

  17. The Performance of the Four Anaerobic Blood Culture Bottles BacT/ALERT-FN, -FN Plus, BACTEC-Plus and -Lytic in Detection of Anaerobic Bacteria and Identification by Direct MALDI-TOF MS.

    PubMed

    Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan

    2015-01-01

    Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.

  18. Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products.

    PubMed

    Parveen, Seema; Kaur, Simleen; David, Selwyn A Wilson; Kenney, James L; McCormick, William M; Gupta, Rajesh K

    2011-10-19

    Most biological products, including vaccines, administered by the parenteral route are required to be tested for sterility at the final container and also at various stages during manufacture. The sterility testing method described in the Code of Federal Regulations (21 CFR 610.12) and the United States Pharmacopoeia (USP, Chapter <71>) is based on the observation of turbidity in liquid culture media due to growth of potential contaminants. We evaluated rapid microbiological methods (RMM) based on detection of growth 1) by adenosine triphosphate (ATP) bioluminescence technology (Rapid Milliflex(®) Detection System [RMDS]), and 2) by CO(2) monitoring technologies (BacT/Alert and the BACTEC systems), as alternate sterility methods. Microorganisms representing Gram negative, Gram positive, aerobic, anaerobic, spore forming, slow growing bacteria, yeast, and fungi were prepared in aliquots of Fluid A or a biological matrix (including inactivated influenza vaccines) to contain approximately 0.1, 1, 10 and 100 colony forming units (CFU) in an inoculum of 10 ml. These preparations were inoculated to the specific media required for the various methods: 1) fluid thioglycollate medium (FTM) and tryptic soy broth (TSB) of the compendial sterility method (both membrane filtration and direct inoculation); 2) tryptic soy agar (TSA), Sabouraud dextrose agar (SDA) and Schaedler blood agar (SBA) of the RMDS; 3) iAST and iNST media of the BacT/Alert system and 4) Standard 10 Aerobic/F and Standard Anaerobic/F media of the BACTEC system. RMDS was significantly more sensitive in detecting various microorganisms at 0.1CFU than the compendial methods (p<0.05), whereas the compendial membrane filtration method was significantly more sensitive than the BACTEC and BacT/Alert methods (p<0.05). RMDS detected all microorganisms significantly faster than the compendial method (p<0.05). BacT/Alert and BACTEC methods detected most microorganisms significantly faster than the compendial method (p<0.05), but took almost the same time to detect the slow growing microorganism P. acnes, compared to the compendial method. RMDS using SBA detected all test microorganisms in the presence of a matrix containing preservative 0.01% thimerosal, whereas the BacT/Alert and BACTEC systems did not consistently detect all the test microorganisms in the presence of 0.01% thimerosal. RMDS was compatible with inactivated influenza vaccines and aluminum phosphate or aluminum hydroxide adjuvants at up to 8 mg/ml without any interference in bioluminescence. RMDS was shown to be acceptable as an alternate sterility method taking 5 days as compared to the 14 days required of the compendial method. Isolation of microorganisms from the RMDS was accomplished by re-incubation of membranes with fresh SBA medium and microbial identification was confirmed using the MicroSEQ Identification System. BacT/Alert and BACTEC systems may be applicable as alternate methods to the compendial direct inoculation sterility method for products that do not contain preservatives or anti-microbial agents. Published by Elsevier Ltd.

  19. Early identification of microorganisms in blood culture prior to the detection of a positive signal in the BACTEC FX system using matrix-assisted laser desorption/ionization-time of flight mass spectrometry.

    PubMed

    Wang, Ming-Cheng; Lin, Wei-Hung; Yan, Jing-Jou; Fang, Hsin-Yi; Kuo, Te-Hui; Tseng, Chin-Chung; Wu, Jiunn-Jong

    2015-08-01

    Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) is a valuable method for rapid identification of blood stream infection (BSI) pathogens. Integration of MALDI-TOF MS and blood culture system can speed the identification of causative BSI microorganisms. We investigated the minimal microorganism concentrations of common BSI pathogens required for positive blood culture using BACTEC FX and for positive identification using MALDI-TOF MS. The time to detection with positive BACTEC FX and minimal incubation time with positive MALDI-TOF MS identification were determined for earlier identification of common BSI pathogens. The minimal microorganism concentrations required for positive blood culture using BACTEC FX were >10(7)-10(8) colony forming units/mL for most of the BSI pathogens. The minimal microorganism concentrations required for identification using MALDI-TOF MS were > 10(7) colony forming units/mL. Using simulated BSI models, one can obtain enough bacterial concentration from blood culture bottles for successful identification of five common Gram-positive and Gram-negative bacteria using MALDI-TOF MS 1.7-2.3 hours earlier than the usual time to detection in blood culture systems. This study provides an approach to earlier identification of BSI pathogens prior to the detection of a positive signal in the blood culture system using MALDI-TOF MS, compared to current methods. It can speed the time for identification of BSI pathogens and may have benefits of earlier therapy choice and on patient outcome. Copyright © 2013. Published by Elsevier B.V.

  20. Comparison of Susceptibility Testing of Mycobacterium tuberculosis Using the ESP Culture System II with That Using the BACTEC Method

    PubMed Central

    Ruiz, P.; Zerolo, F. J.; Casal, M. J.

    2000-01-01

    The ESP Culture System II was evaluated for its capacity to test the susceptibility of 389 cultures of Mycobacterium tuberculosis to streptomycin, rifampin, ethambutol, and isoniazid. Good agreement with results with the BACTEC TB 460 was found. ESP II is a reliable, rapid, and automated method for performing susceptibility testing. PMID:11101619

  1. Stability of amoxicillin-clavulanate in BACTEC medium determined by high-performance liquid chromatography and bioassay.

    PubMed Central

    Moore, T D; Horton, R; Utrup, L J; Miller, L A; Poupard, J A

    1996-01-01

    The stabilities of amoxicillin (16 micrograms/ml) and clavulanate (8 micrograms/ml), alone and in combination in BACTEC medium (Middlebrook 7H12B medium), were determined by high-performance liquid chromatography (HPLC) and bioassay. By HPLC, the half-life of amoxicillin (trihydrate and sodium) in combination with clavulanate in nonradiolabelled 7H12B medium was 6.7 days, whereas the half-life of clavulanate in combination with amoxicillin was 2.0 days. By bioassay, the half-lives of amoxicillin trihydrate and clavulanate in radiolabelled 7H12B medium were comparable (7 and 2 days, respectively) to those determined by HPLC. When clavulanate was tested alone, the half-life was determined to be 1.88 days by HPLC and 1.87 days by bioassay. The relatively short half-life of clavulanate can be adjusted by a procedure of "topping up," or adding one-half the concentration of clavulanate every second day, in order to allow accurate amoxicillin-clavulanate MIC testing with the BACTEC mycobacterial susceptibility system. PMID:8727931

  2. Rapid Detection and Identification of Candidemia by Direct Blood Culturing on Solid Medium by Use of Lysis-Centrifugation Method Combined with Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS).

    PubMed

    Idelevich, Evgeny A; Grünastel, Barbara; Becker, Karsten

    2017-01-01

    Candida sepsis is a life-threatening condition with increasing prevalence. In this study, direct blood culturing on solid medium using a lysis-centrifugation procedure enabled successful Candida species identification by matrix-assisted laser desorption-ionization time of flight mass spectrometry on average 3.8 h (Sabouraud agar) or 7.4 h (chocolate agar) before the positivity signal for control samples in Bactec mycosis-IC/F or Bactec Plus aerobic/F bottles, respectively. Direct culturing on solid medium accelerated candidemia diagnostics compared to that with automated broth-based systems. Copyright © 2016 American Society for Microbiology.

  3. Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?

    PubMed

    Mueller-Premru, Manica; Jeverica, Samo; Papst, Lea; Nagy, Elisabeth

    2017-06-01

    We studied the performance characteristics of two blood culture (BC) bottles/systems, (i) BacT/ALERT-FN Plus/3D (bioMérieux, Marcy l'Étoile, France) and (ii) BACTEC-Lytic/9000 (Becton Dickinson, Sparks, USA) for detection of growth and time-to-positivity (TTP) against a balanced and diverse collection of anaerobic bacterial strains (n = 48) that included reference strains (n = 19) and clinical isolates (n = 29) of 32 species (15 Gram-negative and 17 Gram-positive). Standard suspension of bacteria was inoculated to each bottle in duplicates and incubated in the corresponding system. Overall, 62.5% (n = 30) of strains were detected by both BC bottle types. Comparing the two, 70.8% (n = 34) and 79.2% (n = 38) of strains were detected by BacT/ALERT-FN Plus and BACTEC-Lytic bottles, respectively (p = 0.38). Among Gram-negative anaerobes (n = 25) the detection rate was 76.0% (n = 19) vs. 92.0% (n = 23) (p = 0.22), respectively. Among Gram-positive anaerobes (n = 23) the detection rate was 65.2% (n = 15) in both bottles (p = 1). The average TTP per bottle was calculated only for the strains detected by both systems (n = 30) and was 40.85 h and 28.08 h for BacT/ALERT-FN Plus and BACTEC-Lytic, respectively (p < 0.001). The mean difference was 12.76 h (95% CI: 6.21-19-31 h). Six anaerobic strains were not detected by any system, including Gram-negative Porphyromonas gingivalis, and five Gram-positive strains: Finegoldia magna, Peptostreptococcus anaerobius, Propionibacterium acnes, Clostridium novyi and Clostridium clostridioforme. Furthermore, Eggerthella lenta and Prevotella bivia were detected only by BacT/ALERT-FN Plus, while Prevotella disiens and Prevotella intermedia were detected only by BACTEC-Lytic bottles. There were no major differences in detection rate among clinical and reference strains. Anaerobic bacteria represent a minority of BC isolates, however, far from ideal detection rate was observed in this study for both tested bottle/system combinations. Nevertheless, in those cases where both gave positive signal, BACTEC-Lytic was superior to BacT/ALERT FN Plus with 12.76 h shorter mean TTP. Improvements of media in blood culture bottles available for detection of anaerobes are warranted. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. The Bactec FX Blood Culture System Detects Brucella melitensis Bacteremia in Adult Patients within the Routine 1-Week Incubation Period.

    PubMed

    Sagi, Moshe; Nesher, Lior; Yagupsky, Pablo

    2017-03-01

    The performance of the Bactec FX blood culture system for detecting Brucella bacteremia within the routine 1-week incubation period was assessed in a prospective study conducted in an area in southern Israel in which Brucella melitensis is endemic. Aerobic vials (BD Bactec Plus Aerobic/F medium) inoculated with blood specimens obtained from adult patients with positive Rose-Bengal screening test results were monitored for 4 consecutive weeks, and blind subcultures of negative vials were performed on solid media on days 7 and 28. During a 16-month period, a total of 31 (35.2%) of 88 cultures, obtained from 19 (38.0%) of 50 patients, were positive for Brucella melitensis The blood culture instrument identified 30 (96.8%) of 31 positive vials within 7 days of incubation; the single positive vial that was missed by the automated readings was detected only by the blind subculture performed on day 28. It is concluded that the Bactec FX system is able to detect the vast majority of episodes of Brucella bacteremia within the 1-week incubation protocol instituted in most clinical microbiology laboratories and without the need to perform blind subcultures of negative vials, enabling early diagnosis and saving labor and incubation time and space. Copyright © 2017 American Society for Microbiology.

  5. A dramatic increase in the positive blood culture rates of Helicobacter cinaedi: the evidence of differential detection abilities between the Bactec and BacT/Alert systems.

    PubMed

    Miyake, Noriko; Chong, Yong; Nishida, Ruriko; Nagasaki, Yoji; Kibe, Yasushi; Kiyosuke, Makiko; Shimomura, Takeshi; Shimono, Nobuyuki; Shimoda, Shinji; Akashi, Koichi

    2015-11-01

    In our hospital, positive blood culture rates of Helicobacter cinaedi dramatically increased after introducing the Bactec system. A simulated culture model of H. cinaedi bacteremia demonstrated no positive signals using the BacT/Alert system, despite efficient growth in bottles. Clinically suspected H. cinaedi bacteremia should be monitored more closely when using the BacT/Alert system, preferably with subcultivation after 7days of incubation. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Performance of Mycobacterium Growth Indicator Tube BACTEC 960 with Lowenstein-Jensen method for diagnosis of Mycobacterium tuberculosis at Ethiopian National Tuberculosis Reference Laboratory, Addis Ababa, Ethiopia.

    PubMed

    Diriba, Getu; Kebede, Abebaw; Yaregal, Zelalem; Getahun, Muluwork; Tadesse, Mengistu; Meaza, Abyot; Dagne, Zekarias; Moga, Shewki; Dilebo, Jibril; Gudena, Kebebe; Hassen, Mulu; Desta, Kassu

    2017-05-10

    Bacteriological confirmed active case detection remains the corner stone for diagnosing tuberculosis. Non-radiometric liquid culture system Mycobacterium Growth Indicator Tube with automated interface had been recommended by expert groups in addition to conventional solid culture media such as Lowenstein-Jensen. However in high burden resource limited countries advanced non-radiometric based tuberculosis diagnostic methods such as MGIT 960 is limited. Therefore we have evaluated the performance of MGIT 960 system compared to LJ for recovery of Mycobacterium complex (MTBC) from clinical specimens. A cross sectional study was conducted from a total of 908 samples between January 1st, 2013 to December 31st, 2014. Clinical specimens were processed following standard procedures and the final suspension was inoculated to MGIT tubes and LJ slant. Identification and confirmation of MTBC was done by ZN staining and SD Bioline test. Data was analyzed by SPSS version 20. The sensitivity, specificity, recovery rate and the average turnaround time to recover the organism was computed. From a total of 908 clinical specimens processed using both LJ and BACTEC MGIT liquid culture methods the recovery rate for LJ and MGIT, for smear positive samples was 66.7% (74/111) and 87.4% (97/ 111) respectively while for smear negative samples was 13.4% (108/797) and 17.4% (139/797) for LJ and MGIT methods respectively. The overall recovery rate for MGIT is significantly higher than LJ methods [26% (236/908; vs. 20%, 182/908, P = 0.002)]. The average turnaround time for smear positive samples was 16 and 31 days for MGIT and LJ respectively. Turnaround time for smear negative samples was 20 and 36 days for MGIT and LJ respectively. The overall agreement between MGIT and LJ was fairly good with Kappa value of 0.59 (P < 0.001). In the present study the contamination rate for MGIT is higher than the LJ methods, 15 and 9.3% respectively. The BACTEC MGIT liquid culture system has better MTBC recovery rate with shorter turnaround time for both smear positive and negative clinical specimens compared to Conventional LJ method. However, efforts should be made in order to reduce the high contamination rate in BACTEC MGIT system and to lesser extent to LJ methods.

  7. Development and Validation of a Liquid Medium (M7H9C) for Routine Culture of Mycobacterium avium subsp. paratuberculosis To Replace Modified Bactec 12B Medium

    PubMed Central

    Whittington, Ann-Michele; Waldron, Anna; Begg, Douglas J.; de Silva, Kumi; Purdie, Auriol C.; Plain, Karren M.

    2013-01-01

    Liquid culture of Mycobacterium avium subsp. paratuberculosis from clinical samples, such as feces, is the most sensitive antemortem test for the diagnosis of Johne's disease in ruminants. In Australia, New Zealand, the United States, and some other countries, the Bactec 460 system with modified Bactec 12B medium (Becton, Dickinson) has been the most commonly used liquid culture system, but it was discontinued in 2012. In this study, a new liquid culture medium, M7H9C, was developed. It consists of a Middlebrook 7H9 medium base with added Casitone, albumin, dextrose, catalase, egg yolk, mycobactin J, and a cocktail of antibiotics. We found that polyoxyethylene stearate (POES) was not essential for the cultivation of M. avium subsp. paratuberculosis in either the Bactec 12B or the M7H9C medium. The limit of detection determined using pure cultures of the C and S strains of M. avium subsp. paratuberculosis was 7 bacilli per 50 μl inoculum in the two media. The new medium was validated using 784 fecal and tissue samples from sheep and cattle, >25% of which contained viable M. avium subsp. paratuberculosis. Discrepant results for the clinical samples between the two media were mostly associated with samples that contained <10 viable bacilli per gram, but these results were relatively uncommon, and the performances of the two media were not significantly different. M7H9C medium was less than half the cost of the Bactec 12B medium and did not require regular examination during incubation, but a confirmatory IS900 PCR test had to be performed on every culture after the predetermined incubation period. PMID:24048541

  8. Wild-type MIC distributions of four fluoroquinolones active against Mycobacterium tuberculosis in relation to current critical concentrations and available pharmacokinetic and pharmacodynamic data.

    PubMed

    Angeby, K A; Jureen, P; Giske, C G; Chryssanthou, E; Sturegård, E; Nordvall, M; Johansson, A G; Werngren, J; Kahlmeter, G; Hoffner, S E; Schön, T

    2010-05-01

    To describe wild-type distributions of the MIC of fluoroquinolones for Mycobacterium tuberculosis in relation to current critical concentrations used for drug susceptibility testing and pharmacokinetic/pharmacodynamic (PK/PD) data. A 96-stick replicator on Middlebrook 7H10 medium was used to define the MICs of ciprofloxacin, ofloxacin, moxifloxacin and levofloxacin for 90 consecutive clinical strains and 24 drug-resistant strains. The MICs were compared with routine BACTEC 460 susceptibility results and with MIC determinations in the BACTEC MGIT 960 system in a subset of strains using ofloxacin as a class representative. PK/PD data for each drug were reviewed in relation to the wild-type MIC distribution. The wild-type MICs of ciprofloxacin, ofloxacin, moxifloxacin and levofloxacin were distributed from 0.125 to 1, 0.25 to 1, 0.032 to 0.5 and 0.125 to 0.5 mg/L, respectively. The MIC data correlated well with the BACTEC 960 MGIT and BACTEC 460 results. PD indices were the most favourable for levofloxacin, followed by moxifloxacin, ofloxacin and ciprofloxacin. We propose S (susceptible)

  9. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system.

    PubMed

    Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F

    2011-01-01

    Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  10. Verification of false-positive blood culture results generated by the BACTEC 9000 series by eubacterial 16S rDNA and panfungal 18S rDNA directed polymerase chain reaction (PCR).

    PubMed

    Daxboeck, Florian; Dornbusch, Hans Jürgen; Krause, Robert; Assadian, Ojan; Wenisch, Christoph

    2004-01-01

    A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms.

  11. Comparison between Bactec Peds Plus F Broth and Conventional Medium for Vitreous Culture.

    PubMed

    Tabatabaei, Seyed Ali; Tabatabaei, Seyed Mehdi; Soleimani, Mohammad; Hejrati, Bahman; Mirshahi, Ahmad; Khadabandeh, Alireza; Ahmadraji, Aliasghar; Valipour, Niloofar

    2018-05-10

    To evaluate the yield of Bactec Peds Plus F broth for vitreous sample culture in cases with infectious endophthalmitis in comparison to conventional medium. Consecutive cases of clinically suspected endophthalmitis were prospectively enrolled in this study. Cultures of the vitreous sample were performed in both Bactec Peds Plus F broth and conventional mediums. Forty eyes of 40 patients who were clinically suspected of infectious endophthalmitis with different etiologies were enrolled in this study. The positive culture yield was 50% and 35% in Bactec Peds Plus F broth and conventional mediums, respectively (p = 0.07). The result of Bactec group was not significantly different among patients who had a history of intravitreal antibiotic injection (p > 0.05) (Table 2). However, results of the conventional method were significantly negative in the previous intravitreal antibiotic injection group (p = 0.02). There was no correlation between the methods of vitreous sampling in both culture methods. Although the difference between two culture methods was not statistically significant in this study, Bactec Peds Plus F broth showed higher positive culture yield in patients with a history of intravitreal antibiotic injection.

  12. Evaluation of the BACTEC MGIT 960 SL DST Kit and the GenoType MTBDRsl Test for Detecting Extensively Drug-resistant Tuberculosis Cases

    PubMed Central

    Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa

    2017-01-01

    Objective: The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Materials and Methods: Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. Results: The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. Conclusion: The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis. PMID:29123441

  13. Evaluation of the BACTEC MGIT 960 SL DST Kit and the GenoType MTBDRsl Test for Detecting Extensively Drug-resistant Tuberculosis Cases.

    PubMed

    Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa

    2017-10-01

    The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis.

  14. Comparative performance of PCR-based assay versus microscopy and culture for the direct detection of Mycobacterium tuberculosis in clinical respiratory specimens in Lebanon.

    PubMed

    Araj, G F; Talhouk, R S; Itani, L Y; Jaber, W; Jamaleddine, G W

    2000-09-01

    American University of Beirut Medical Center, Lebanon. To assess the performance of a polymerase chain reaction (PCR) using primers that flank 542 bp within IS6110 in Mycobacterium tuberculosis (TB) vs. microscopy and BACTEC culture, in the diagnosis of tuberculosis. A total of 82 clinical respiratory pulmonary specimens and 73 samples from BACTEC vials were tested by the three methods. Of 24 smear-positive culture-positive (SP-CP) and 11 smear-negative culture-positive (SN-CP) TB specimens, PCR detected 83% and 64%, respectively. Among 17 specimens yielding mycobacteria other than tuberculosis (MOTT), the PCR was positive in 33% SP-CP and 14% SN-CP specimens. Among the 73 BACTEC vials, PCR was positive in 36 of 38 (95%) yielding culture-positive TB, and in one of 20 (5%) yielding culture positive MOTT. None of the 30 smear-negative culture-negative (SN-CN) clinical specimens and 15 of the CN vials were positive by PCR. The overall sensitivity of PCR was 77% and 95% for TB detection in respiratory specimens and BACTEC vials, respectively, and the specificity was 94% in both. Because a substantial number of TB cases are missed, especially in SN-CP specimens, a PCR-based assay utilizing these primers cannot be used reliably, alone, in clinical laboratory diagnosis of mycobacterial respiratory infections.

  15. Factors affecting isolation and identification of Mycobacterium avium subsp. paratuberculosis from fecal and tissue samples in a liquid culture system.

    PubMed

    Whittington, Richard J

    2009-03-01

    Culture of Mycobacterium avium subsp. paratuberculosis is the definitive diagnostic test for Johne's disease, a chronic granulomatous enteropathy of animals. Compared to solid media, the identification of all strains of the organism in liquid media can be more difficult because the appearance of colonies and mycobactin dependence are not observable, and the growth of other organisms needs to be distinguished, commonly by PCR. Factors affecting the isolation rate of S strains and the contamination rate in modified Middlebrook 7H9 broth (Bactec 12B) and 7H10 agar were studied using 11,598 fecal samples and 2,577 tissue samples from sheep from 1,421 farms over 10 years. Minimization of contamination in Bactec cultures required the avoidance of the carryover of fecal particles from the first sedimentation step in the double-incubation centrifugation method, and contamination was reduced significantly by incubating the sample in a solution containing vancomycin, amphotericin B, and nalidixic acid for 3 days compared to 2 days. The growth of irrelevant microorganisms confounded the identification of M. avium subsp. paratuberculosis in liquid culture by inhibiting IS900 PCR and in solid medium culture by inhibiting the growth of M. avium subsp. paratuberculosis or obscuring colonies. The contamination of samples was clustered in certain laboratory submissions and was reduced by including ampicillin in Bactec medium without affecting the odds of isolation of M. avium subsp. paratuberculosis. The long-term contamination rate for fecal cultures was about 7%, and that for tissue cultures was <0.2%. Liquid medium was more sensitive than solid medium culture for M. avium subsp. paratuberculosis. The applicability of these findings for C strains is discussed.

  16. Detection of Salmonella spp. with the BACTEC 9240 Automated Blood Culture System in 2008 - 2014 in Southern Iran (Shiraz): Biogrouping, MIC, and Antimicrobial Susceptibility Profiles of Isolates.

    PubMed

    Anvarinejad, Mojtaba; Pouladfar, Gholam Reza; Pourabbas, Bahman; Amin Shahidi, Maneli; Rafaatpour, Noroddin; Dehyadegari, Mohammad Ali; Abbasi, Pejman; Mardaneh, Jalal

    2016-04-01

    Human salmonellosis continues to be a major international problem, in terms of both morbidity and economic losses. The antibiotic resistance of Salmonella is an increasing public health emergency, since infections from resistant bacteria are more difficult and costly to treat. The aims of the present study were to investigate the isolation of Salmonella spp. with the BACTEC automated system from blood samples during 2008 - 2014 in southern Iran (Shiraz). Detection of subspecies, biogrouping, and antimicrobial susceptibility testing by the disc diffusion and agar dilution methods were performed. A total of 19 Salmonella spp. were consecutively isolated using BACTEC from blood samples of patients between 2008 and 2014 in Shiraz, Iran. The isolates were identified as Salmonella, based on biochemical tests embedded in the API-20E system. In order to characterize the biogroups and subspecies, biochemical testing was performed. Susceptibility testing (disc diffusion and agar dilution) and extended-spectrum β-lactamase (ESBL) detection were performed according to the clinical and laboratory standards institute (CLSI) guidelines. Of the total 19 Salmonella spp. isolates recovered by the BACTEC automated system, all belonged to the Salmonella enterica subsp. houtenae. Five isolates (26.5%) were resistant to azithromycin. Six (31.5%) isolates with the disc diffusion method and five (26.3%) with the agar dilution method displayed resistance to nalidixic acid (minimum inhibitory concentration [MIC] > 32 μg/mL). All nalidixic acid-resistant isolates were also ciprofloxacin-sensitive. All isolates were ESBL-negative. Twenty-one percent of isolates were found to be resistant to chloramphenicol (MIC ≥ 32 μg/mL), and 16% were resistant to ampicillin (MIC ≥ 32 μg/mL). The results indicate that multidrug-resistant (MDR) strains of Salmonella are increasing in number, and fewer antibiotics may be useful for treating S. enterica infections. Routine investigation and reporting of antibiotic MICs in patients presenting with Salmonella infections is suggested.

  17. Rapid identification of fungal pathogens in BacT/ALERT, BACTEC, and BBL MGIT media using polymerase chain reaction and DNA sequencing of the internal transcribed spacer regions.

    PubMed

    Pryce, Todd M; Palladino, Silvano; Price, Diane M; Gardam, Dianne J; Campbell, Peter B; Christiansen, Keryn J; Murray, Ronan J

    2006-04-01

    We report a direct polymerase chain reaction/sequence (d-PCRS)-based method for the rapid identification of clinically significant fungi from 5 different types of commercial broth enrichment media inoculated with clinical specimens. Media including BacT/ALERT FA (BioMérieux, Marcy l'Etoile, France) (n = 87), BACTEC Plus Aerobic/F (Becton Dickinson, Microbiology Systems, Sparks, MD) (n = 16), BACTEC Peds Plus/F (Becton Dickinson) (n = 15), BACTEC Lytic/10 Anaerobic/F (Becton Dickinson) (n = 11) bottles, and BBL MGIT (Becton Dickinson) (n = 11) were inoculated with specimens from 138 patients. A universal DNA extraction method was used combining a novel pretreatment step to remove PCR inhibitors with a column-based DNA extraction kit. Target sequences in the noncoding internal transcribed spacer regions of the rRNA gene were amplified by PCR and sequenced using a rapid (24 h) automated capillary electrophoresis system. Using sequence alignment software, fungi were identified by sequence similarity with sequences derived from isolates identified by upper-level reference laboratories or isolates defined as ex-type strains. We identified Candida albicans (n = 14), Candida parapsilosis (n = 8), Candida glabrata (n = 7), Candida krusei (n = 2), Scedosporium prolificans (n = 4), and 1 each of Candida orthopsilosis, Candida dubliniensis, Candida kefyr, Candida tropicalis, Candida guilliermondii, Saccharomyces cerevisiae, Cryptococcus neoformans, Aspergillus fumigatus, Histoplasma capsulatum, and Malassezia pachydermatis by d-PCRS analysis. All d-PCRS identifications from positive broths were in agreement with the final species identification of the isolates grown from subculture. Earlier identification of fungi using d-PCRS may facilitate prompt and more appropriate antifungal therapy.

  18. Acid-fast bacilli culture positivity and drug resistance in abdominal tuberculosis in Mumbai, India.

    PubMed

    Samant, Hrishikesh; Desai, Devendra; Abraham, Philip; Joshi, Anand; Gupta, Tarun; Rodrigues, Camilla; George, Siji

    2014-09-01

    Culture positivity for Mycobacterium tuberculosis complex (MTB) in abdominal tuberculosis (TB) using Lowenstein Jensen medium and Bactec system varies from 25 % to 36 %. Data on the prevalence of drug resistance in primary abdominal TB is scant. Our aim was to study the acid-fast bacilli (AFB) culture positivity rate in primary abdominal TB using Bactec Mycobacterial Growth Indicator Tubes (MGIT) system and the prevalence of drug resistance in these patients. Records of patients with abdominal TB (diagnosed on clinical features, endoscopy, histology, microbiology) seen during the period 2008 to 2013 were retrieved from the Gastroenterology and Microbiology departments. Patients with extra-abdominal TB (five pulmonary, two nodal), adnexal (one), and HIV (one) were excluded from analysis. Of 61 patients, 31 (50.8 %) had a positive AFB culture. In the 30 culture-negative patients, histology showed non-caseating granulomas in 25 patients. Drug sensitivity pattern was analyzed in 18 patients; resistance was detected in eight (14.3 % of all patients and 44.4 % of patients in whom drug sensitivity was done) including three (5.4 % of all subjects and 16.6 % in whom drug sensitivity was available) who were multidrug-resistant. The rate of AFB culture positivity in primary abdominal TB was 50.8 % using Bactec MGIT. Likelihood of drug resistance was seen in 14.3 %, of whom 5.4 % were multidrug-resistant.

  19. Comparison of the clinical and microbiological characteristics of Campylobacter and Helicobacter bacteremia: the importance of time to blood culture positivity using the BACTEC blood culture systems.

    PubMed

    Yamamoto, Kei; Hayakawa, Kayoko; Nagashima, Maki; Shimada, Kayo; Kutsuna, Satoshi; Takeshita, Nozomi; Kato, Yasuyuki; Kanagawa, Shuzo; Yamada, Koji; Mezaki, Kazuhisa; Kirikae, Teruo; Ohmagari, Norio

    2017-11-28

    Campylobacter spp. and Helicobacter spp. are rare but important causes of bacteremia in humans. Distinguishing these bacteria is complicated because of their similar phenotypic profiles. We conducted clinical and microbiological investigations of Campylobacter spp. or Helicobacter spp. bacteremia. Patients diagnosed with bacteremia from 2008 to 2014 were included. The clinical and microbiological characteristics of Campylobacter spp. and Helicobacter spp. bacteremia were compared. The BACTEC system was used in blood cultures. A receiver operating characteristic curve was plotted based on the time to blood culture positivity. Sixteen cases of Helicobacter spp. bacteremia (patient age: 61 ± 18 years) and 14 cases of Campylobacter spp. bacteremia (patient age: 49 ± 21 years) were identified. Median time to blood culture positivity was longer for the Helicobacter spp. cases than the Campylobacter spp. cases (91.4 h vs 55.3 h, p < 0.01). A time to blood culture positivity > 75 h predicted Helicobacter spp. bacteremia with a sensitivity of 0.88 and a specificity of 0.93 (area under the receiver operating characteristic curve of 0.90). In conclusion, a time to blood culture positivity was useful in distinguishing Helicobacter spp. bacteremia from Campylobacter spp. bacteremia.

  20. A new approach for pyrazinamide susceptibility testing in Mycobacterium tuberculosis.

    PubMed

    Zimic, Mirko; Loli, Sebastian; Gilman, Robert H; Gutierrez, Andrés; Fuentes, Patricia; Cotrina, Milagros; Kirwan, Daniela; Sheen, Patricia

    2012-08-01

    Pyrazinamide (PZA) is an important drug in the treatment of tuberculosis. Microbiological methods of PZA susceptibility testing are controversial and have low reproducibility. After conversion of PZA into pyrazinoic acid (POA) by the bacterial pyrazinamidase enzyme, the drug is expelled from the bacteria by an efflux pump. To evaluate the rate of POA extrusion from Mycobacterium tuberculosis as a parameter to detect PZA resistance. The rate of POA extrusion and PZA susceptibility determined by BACTEC 460 were measured for 34 strains in a previous study. PZA resistance was modeled in a logistic regression with the pyrazinoic efflux rate. POA efflux rate predicted PZA resistance with 70.83%-92.85% sensitivity and 100% specificity compared with BACTEC 460. POA efflux rate could be a useful tool for predicting PZA resistance in M. tuberculosis. Further exploration of this approach may lead to the development of new tools for diagnosing PZA resistance, which may be of public health importance.

  1. Validation of shortened 2-day sterility testing of mesenchymal stem cell-based therapeutic preparation on an automated culture system.

    PubMed

    Lysák, Daniel; Holubová, Monika; Bergerová, Tamara; Vávrová, Monika; Cangemi, Giuseppina Cristina; Ciccocioppo, Rachele; Kruzliak, Peter; Jindra, Pavel

    2016-03-01

    Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10-100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10-100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and allows their timely release for clinical application.

  2. Production of UC-labeled gas in BACTEC Neisseria Differentiation kits by Neisseria cinerea

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyce, J.M.; Mitchell, E.B. Jr.; Knapp, J.S.

    1985-09-01

    Six strains of Neisseria cinerea were tested in BACTEC Neisseria Differentiation kits (Johnston Laboratories, Inc., Towson, Md.), and all yielded positive glucose growth indices and negative maltose and fructose growth indices. These results were similar to those achieved with Neisseria gonorrhoeae. However, most of the N. cinerea isolates tested yielded 3-h glucose growth indices that were lower than those obtained with gonococci. UC-labeled gas was produced significantly faster by N. gonorrhoeae than by N. cinerea. Additional studies suggested that the UC-labeled gas produced by N. cinerea was carbon dioxide. N. cinerea strains were similar to Branhamella catarrhalis strains because bothmore » species failed to produce detectable acid from glucose, maltose, sucrose, fructose, and lactose in cysteine-tryptic agar media. However, in contrast to N. cinerea strains, B. catarrhalis strains did not metabolize glucose in BACTEC Neisseria Differentiation kits.« less

  3. Rapid culture-based detection of living mycobacteria using microchannel electrical impedance spectroscopy (m-EIS).

    PubMed

    Kargupta, Roli; Puttaswamy, Sachidevi; Lee, Aiden J; Butler, Timothy E; Li, Zhongyu; Chakraborty, Sounak; Sengupta, Shramik

    2017-06-10

    Multiple techniques exist for detecting Mycobacteria, each having its own advantages and drawbacks. Among them, automated culture-based systems like the BACTEC-MGIT™ are popular because they are inexpensive, reliable and highly accurate. However, they have a relatively long "time-to-detection" (TTD). Hence, a method that retains the reliability and low-cost of the MGIT system, while reducing TTD would be highly desirable. Living bacterial cells possess a membrane potential, on account of which they store charge when subjected to an AC-field. This charge storage (bulk capacitance) can be estimated using impedance measurements at multiple frequencies. An increase in the number of living cells during culture is reflected in an increase in bulk capacitance, and this forms the basis of our detection. M. bovis BCG and M. smegmatis suspensions with differing initial loads are cultured in MGIT media supplemented with OADC and Middlebrook 7H9 media respectively, electrical "scans" taken at regular intervals and the bulk capacitance estimated from the scans. Bulk capacitance estimates at later time-points are statistically compared to the suspension's baseline value. A statistically significant increase is assumed to indicate the presence of proliferating mycobacteria. Our TTDs were 60 and 36 h for M. bovis BCG and 20 and 9 h for M. smegmatis with initial loads of 1000 CFU/ml and 100,000 CFU/ml respectively. The corresponding TTDs for the commercial BACTEC MGIT 960 system were 131 and 84.6 h for M. bovis BCG and 41.7 and 12 h for M smegmatis, respectively. Our culture-based detection method using multi-frequency impedance measurements is capable of detecting mycobacteria faster than current commercial systems.

  4. [Utility of the direct culture examination (Ziehl-Neelsen) using the Bactec system for the presumptive identification of Mycobacterium tuberculosis complex, Mycobacterium avium complex, Mycobacterium xenopi, and Mycobacterium kansasii].

    PubMed

    Moreno, C; Garrigó, M; Sánchez, F; Coll, P

    1994-05-01

    The usefulness of the microscopic examination of Bactec 12B and 13A growth medium as a method for the possible identification of M. tuberculosis complex, M. avium complex, M. xenopi, and M. kansasii was performed out to guide the selection of different genetic identification probes and, in the case of M. xenopi, the selection of the temperature of subcultures incubation. Upon detection of an index of growth greater than 100 in Bactec tubes, staining was performed by the Ziehl-Neelsen technique. On the basis of the morphology observed, the possible identification was performed by genetic probes. Subcultures were used for definitive identification. Three hundred forty-four positive samples were studied by radiometric technique. A total of 190 strains were identified as M. tuberculosis, 88 strains as M. avium-intracellulare (MAI), 33 strains as M. xenopi, 14 strains as M. kansasii and 19 strains were identified as: M. gordonae (10), unpigmented rapid growth microbacteria (7), and M. simiae (2). Sensitivity, specificity, positive predictive value, and negative predictive value were 97.9%, 95.4%, 96.4%, and 97.3%, respectively for M. tuberculosis complex, 84.0%, 99.2%, 97.3% 94.7% for M. avium complex; 63.6%, 98.3%, 80.7%, 96.2% for M. xenopi; 35.7%, 98.1%, 45.5% 97.2% for M. kansasii. The morphology of M. tuberculosis complex examined in the radiometric system in useful to differentiate this species from other microbacteria (MOTT), allowing the selection of specific probe used. Within the MOTT, M. avium complex also has morphological characteristics which are useful for its differentiation, the morphology usually described for the remaining species was frequently not observed.

  5. A New Approach for Pyrazinamide Susceptibility Testing in Mycobacterium tuberculosis

    PubMed Central

    Loli, Sebastian; Gilman, Robert H.; Gutierrez, Andrés; Fuentes, Patricia; Cotrina, Milagros; Kirwan, Daniela; Sheen, Patricia

    2012-01-01

    Background: Pyrazinamide (PZA) is an important drug in the treatment of tuberculosis. Microbiological methods of PZA susceptibility testing are controversial and have low reproducibility. After conversion of PZA into pyrazinoic acid (POA) by the bacterial pyrazinamidase enzyme, the drug is expelled from the bacteria by an efflux pump. Objective: To evaluate the rate of POA extrusion from Mycobacterium tuberculosis as a parameter to detect PZA resistance. Methods: The rate of POA extrusion and PZA susceptibility determined by BACTEC 460 were measured for 34 strains in a previous study. PZA resistance was modeled in a logistic regression with the pyrazinoic efflux rate. Result: POA efflux rate predicted PZA resistance with 70.83%–92.85% sensitivity and 100% specificity compared with BACTEC 460. Conclusion: POA efflux rate could be a useful tool for predicting PZA resistance in M. tuberculosis. Further exploration of this approach may lead to the development of new tools for diagnosing PZA resistance, which may be of public health importance. PMID:22372927

  6. Evaluation of Verigene Blood Culture Test Systems for Rapid Identification of Positive Blood Cultures.

    PubMed

    Kim, Jae-Seok; Kang, Go-Eun; Kim, Han-Sung; Kim, Hyun Soo; Song, Wonkeun; Lee, Kyu Man

    2016-01-01

    The performance of molecular tests using the Verigene Gram-Positive and Gram-Negative Blood Culture nucleic acid tests (BC-GP and BC-GN, resp.; Naosphere, Northbrook, IL, USA) was evaluated for the identification of microorganisms detected from blood cultures. Ninety-nine blood cultures containing Gram-positive bacteria and 150 containing Gram-negative bacteria were analyzed using the BC-GP and BC-GN assays, respectively. Blood cultures were performed using the Bactec blood culture system (BD Diagnostic Systems, Franklin Lakes, NJ, USA) and conventional identification and antibiotic-susceptibility tests were performed using a MicroScan system (Siemens, West Sacramento, CA, USA). When a single strain of bacteria was isolated from the blood culture, Verigene assays correctly identified 97.9% (94/96) of Gram-positive bacteria and 93.8% (137/146) of Gram-negative bacteria. Resistance genes mecA and vanA were correctly detected by the BC-GP assay, while the extended-spectrum β-lactamase CTX-M and the carbapenemase OXA resistance gene were detected from 30 cases cultures by the BC-GN assay. The BC-GP and BC-GN assays showed high agreement with conventional identification and susceptibility tests. These tests are useful for rapid identification of microorganisms and the detection of clinically important resistance genes from positive Bactec blood cultures.

  7. [Application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance].

    PubMed

    Jin, Yang-Hui; Shi, Shi-Yuan; Zheng, Qi; Shen, Jian; Ying, Xiao-Zhang; Wang, Yi-Fan

    2017-09-25

    To investigate the application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance. The 109 pus specimens were obtained from patients who were primaryly diagnosed as spinal tuberculosis. All of the pus specimens were detected by acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay to definite the differences in sensitivity and specificity of mycobacterium tuberculosis among detecting methods. Pus specimens obtained by different methods were deteceded by MTB/RIF test to analyze the self-influence on Xpert MTB/RIF test. The result of liquid fast culturing by BACTEC MGIT 960 was used as the gold standard; and the value of Xpert MTB/RIF assay in detecting rifampin resistance was analyzed. The sensitivity of acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay were 25.92%, 48.15%, 77.78%, respectively. The sensitivity of pus specimens obtained from open surgery, ultrasound positioning puncture and biopsy the sensitivity were 83.78%, 76.47%, 44.68% respectively deteceded by MTB/RIF test. According to the gold standard of the results of liquid fast culturing by BACTEC MGIT 960 assay, the sensitivity and specificity of Xpert MTB/RIF assay in detecting rifampin resistance were 80%(4/5) and 90.70%(39/43), respectively. Xpert MTB/RIF assay has higher value in diagnosis of spinal tuberculosi, and also can detect rifampin resistance. The number of mycobacterium tuberculosis in pus specimens has a great influence in the sensitivity of Xpert MTB/RIF assay.

  8. Use of Positive Blood Cultures for Direct Identification and Susceptibility Testing with the Vitek 2 System

    PubMed Central

    de Cueto, Marina; Ceballos, Esther; Martinez-Martinez, Luis; Perea, Evelio J.; Pascual, Alvaro

    2004-01-01

    In order to further decrease the time lapse between initial inoculation of blood culture media and the reporting of results of identification and antimicrobial susceptibility tests for microorganisms causing bacteremia, we performed a prospective study in which specially processed fluid from positive blood culture bottles from Bactec 9240 (Becton Dickinson, Cockeysville, Md.) containing aerobic media were directly inoculated into Vitek 2 system cards (bio-Mérieux, France). Organism identification and susceptibility results were compared with those obtained from cards inoculated with a standardized bacterial suspension obtained following subculture to agar; 100 consecutive positive monomicrobic blood cultures, consisting of 50 gram-negative rods and 50 gram-positive cocci, were included in the study. For gram-negative organisms, 31 of the 50 (62%) showed complete agreement with the standard method for species identification, while none of the 50 gram-positive cocci were correctly identified by the direct method. For gram-negative rods, there were 50% categorical agreements between the direct and standard methods for all drugs tested. The very major error rate was 2.4%, and the major error rate was 0.6%. The overall error rate for gram-negatives was 6.6%. Complete agreement in clinical categories of all antimicrobial agents evaluated was obtained for 19 of 50 (38%) gram-positive cocci evaluated; the overall error rate was 8.4%, with 2.8% minor errors, 2.4% major errors, and 3.2% very major errors. These findings suggest that the Vitek 2 cards inoculated directly from positive Bactec 9240 bottles do not provide acceptable bacterial identification or susceptibility testing in comparison with corresponding cards tested by a standard method. PMID:15297523

  9. Performance of Gram staining on blood cultures flagged negative by an automated blood culture system.

    PubMed

    Peretz, A; Isakovich, N; Pastukh, N; Koifman, A; Glyatman, T; Brodsky, D

    2015-08-01

    Blood is one of the most important specimens sent to a microbiology laboratory for culture. Most blood cultures are incubated for 5-7 days, except in cases where there is a suspicion of infection caused by microorganisms that proliferate slowly, or infections expressed by a small number of bacteria in the bloodstream. Therefore, at the end of incubation, misidentification of positive cultures and false-negative results are a real possibility. The aim of this work was to perform a confirmation by Gram staining of the lack of any microorganisms in blood cultures that were identified as negative by the BACTEC™ FX system at the end of incubation. All bottles defined as negative by the BACTEC FX system were Gram-stained using an automatic device and inoculated on solid growth media. In our work, 15 cultures that were defined as negative by the BACTEC FX system at the end of the incubation were found to contain microorganisms when Gram-stained. The main characteristic of most bacteria and fungi growing in the culture bottles that were defined as negative was slow growth. This finding raises a problematic issue concerning the need to perform Gram staining of all blood cultures, which could overload the routine laboratory work, especially laboratories serving large medical centers and receiving a large number of blood cultures.

  10. Rapid mycobacteria drug susceptibility testing using Gel Microdrop (GMD) Growth Assay and flow cytometry.

    PubMed

    Akselband, Y; Cabral, C; Shapiro, D S; McGrath, P

    2005-08-01

    Control of multi-drug-resistant tuberculosis has been hampered by the lack of simple, rapid and sensitive methods for assessing bacterial growth and antimicrobial susceptibility. Due to the increasing incidence and high frequency of mutations, it is unlikely that culture methods will disappear in the foreseeable future. Therefore, the need to modernize methods for rapid detection of viable clinical isolates, at a minimum as a gold standard, will persist. Previously, we confirmed the feasibility of using the Gel Microdrop (GMD) Growth Assay for identifying sub-populations of resistant Mycobacteria by testing different laboratory strains. Briefly, this assay format relies on encapsulating single bacterium in agarose microspheres and identifying clonogenic growth using flow cytometry and fluorescent staining. In this study, we modified the GMD Growth Assay to make it suitable for clinical applications. We demonstrated the effectiveness and safety of this novel approach for detecting drug susceptibility in clinically relevant laboratory strains as well as clinical isolates of Mycobacterium tuberculosis. Correlation between results using the GMD Growth Assay format and results using two well characterized methods (Broth Microdilution MIC and BACTEC 460TB) was 87.5% and 90%, respectively. However, due to the inherent sensitivity of flow cytometry and the ability to detect small (<1%) sub-populations of resistant mycobacteria, the GMD Growth Assay identified more cases of drug resistance. Using 4 clinically relevant mycobacterial strains, we assessed susceptibility to primary anti-tuberculosis drugs using both the Broth Microdilution MIC method and the GMD Growth Assay. We performed 24 tests on isoniazid-resistant BCG, Mycobacterium tuberculosis H37Ra and Mycobacterium avium strains. The Broth Microdilution MIC method identified 7 cases (29.1%) of resistance to INH and EMB compared to the GMD Growth Assay which identified resistance in 10 cases (41.6%); in 3 cases (12.5%), resistance to INH and EMB was detected only with the GMD Growth Assay. In addition, using 20 Mycobacterium tuberculosis clinical isolates, we compared results using BACTEC 460TB method performed by collaborators and the GMD Growth Assay. Eight of 20 (40%) clinical isolates, which were not identified as drug-resistant using the conventional BACTEC 460TB method, were resistant to 1, 2, or 3 different concentrations of drugs using the GMD Growth Assay (13 cases of 140 experiments). In one case (isolate 1879), resistance to 10.0 microg/ml of STR detected using BACTEC 460TB method was not confirmed by the GMD Growth Assay. Thus, the overall agreement between these methods was 90% (14 discrepant results of 140 experiments). These data demonstrate that the GMD Growth Assay is an accurate and sensitive method for rapid susceptibility testing of Mycobacterium tuberculosis for use in clinical reference laboratory settings.

  11. [Tuberculous meningoencephalitis--own observations].

    PubMed

    Garlicki, Aleksander; Kluba-Wojewoda, Urszula; Bociaga-Jasik, Monika; Kalinowska-Nowak, Anna; Sobczyk-Krupiarz, Iwona; Mach, Tomasz

    2003-01-01

    Nine cases of the tuberculous meningoencephalitis in adult men and women treated in years 1993-2000 have been presented. The diagnosis was established on the basis of clinical picture and examination of the cerebrospinal fluid (CSF). Routine analysis of CSF was done, as well as the microscopic examination, biological assay, and culture on the Lowenstein-Jensena medium and using Bactec 460 TB system. Only in one case Mycobacterium tuberculosis was found in the smear of CSF stained by Ziehl-Nielsen method. In one case the biologic assay was positive and Mycobacterium tuberculosis was cultured on Lowenstein-Jensen medium. In another 4 cases the pathogen was detected by Bactec 460 TB technique. In 4 cases Mycobacterium tuberculosis was also cultured from the secretion of the respiratory tract, and in one patient urine. On chest X-ray characteristic changes for pulmonary tuberculosis were observed in 5 cases (56%). Seven patients (78%) had hydrocephalus detected on CT scan of the head. One patient died, one (11%) developed persistent complication in form of spastic paralysis of lower extremities and sphincters dysfunction. Seven patients (78%) recovered completely after the 12 months therapy with standard chemotherapeutic regimen for tuberculosis.

  12. Comparison of MGIT and Myco/F lytic liquid-based blood culture systems for recovery of Mycobacterium tuberculosis from pleural fluid.

    PubMed

    Harausz, Elizabeth; Lusiba, John Kafuluma; Nsereko, Mary; Johnson, John L; Toossi, Zahra; Ogwang, Sam; Boom, W Henry; Joloba, Moses L

    2015-04-01

    The specificities and sensitivities of the Bactec mycobacterial growth indicator tube (MGIT) system for the recovery of Mycobacterium tuberculosis from pleural fluid are not statistically different than those of the Myco/F lytic liquid culture system. The time to positivity is shorter in the MGIT system (12.7 versus 20.7 days, respectively; P=0.007). The Myco/F lytic culture system may be an alternative to the MGIT system for diagnosing pleural tuberculosis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Rapid presumptive identification of the Mycobacterium tuberculosis-bovis complex by radiometric determination of heat stable urease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandy, J.H.; Pruden, E.L.; Cox, F.R.

    1983-12-01

    Simple and rapid Bactec methodologies for the determination of neat (unaltered) and heat stable urease activity of mycobacteria are presented. Clinical isolates (63) and stock cultures (32)--consisting of: M. tuberculosis (19), M. bovis (5), M. kansasii (15), M. marinum (4), M. simiae (3), M. scrofulaceum (16), M. gordonae (6), M. szulgai (6), M. flavescens (1), M. gastri (1), M. intracellulare (6), M. fortuitum-chelonei complex (12), and M. smegmatis (1)--were tested for neat urease activity by Bactec radiometry. Mycobacterial isolates (50-100 mg wet weight) were incubated at 35 degrees C for 30 minutes with microCi14C-urea. Urease-positive mycobacteria gave Bactec growth indexmore » (GI) values greater than 100 units, whereas urease-negative species gave values less than 10 GI units. Eighty-three isolates possessing neat urease activity were heated at 80 degrees C for 30 minutes followed by incubation at 35 degrees C for 30 minutes with 1 microCi14C-urea. Mycobacterium tuberculosis-bovis complex demonstrated heat-stable urease activity (GI more than 130 units) and could be distinguished from mycobacteria other than tuberculosis (MOTT), which gave GI values equal to or less than 40 units.« less

  14. Clinical and Diagnostic Aspects of Brucellosis and Antimicrobial Susceptibility of Brucella Isolates in Hamedan, Iran.

    PubMed

    Torkaman Asadi, Fatemeh; Hashemi, Seyyed Hamid; Alikhani, Mohammad Yousef; Moghimbeigi, Abbas; Naseri, Zahra

    2017-05-24

    Current drug regimens for brucellosis are associated with relatively high rates of therapeutic failure or relapse. Reduced antimicrobial susceptibility of Brucella spp. has been proposed recently as a potential cause of therapeutic failure. The aim of this study was to evaluate the antibiotic resistance pattern of Brucella melitensis clinical isolates by E-test method in Hamadan, west of Iran. In a 15-month period, all patients with suspected brucellosis were enrolled. Blood specimens were collected for diagnosis of brucellosis by BACTEC system and serological tests. Antimicrobial susceptibility of clinical isolates to 7 antibiotics was assessed by the E-test method. One hundred forty-nine patients with brucellosis were evaluated. 38.3% of cultures of clinical samples were positive for BACTEC system, of which 91.2% were associated with a positive serological test result. No significant associations were found between serology and the culture method. All Brucella isolates were susceptible to doxycycline, streptomycin, gentamicin, ciprofloxacin, and moxifloxacin. However, decreased sensitivity to rifampin and trimethoprim-sulfamethoxazole was found in 35.1% and 3.5% of isolates, respectively. Because of the high rates of intermediate sensitivity to rifampin among Brucella isolates, this drug should be prescribed with caution. We recommend restricting the use of rifampin for treatment of brucellosis except as an alternative drug for special situations.

  15. Detection of bacterial growth by gas absorption.

    PubMed

    Waters, J R

    1992-05-01

    When 24 different aerobic organisms were grown in a shaken culture, all were found to first absorb gas from the headspace. In a rudimentary medium, such as tryptic soy broth, 16 of the 24 organisms did not produce gas following the initial gas absorption. We have developed a simple, noninvasive method for detecting both gas absorption and production in multiple culture vials. The time to positivity was compared with that obtained by the BACTEC 460 blood culture system. For nearly all of these organisms, there was no difference. For some of those organisms that did not produce gas, e.g. Staphylococcus epidermidis, Moraxella osloensis, and Neisseria meningitidis, detection by gas absorption was a few hours faster. Gas absorption appears to be a promising technique for a new automated blood culture system because of its simplicity and because medium without special additives can be used to detect organisms that do not produce gas.

  16. Prospective study of the clinical performance of three BACTEC media in a modern emergency department: Plus Aerobic/F, Plus Anaerobic/F, and Anaerobic Lytic/F.

    PubMed

    Rocchetti, Andrea; Di Matteo, Luigi; Bottino, Paolo; Foret, Benjamin; Gamalero, Elisa; Calabresi, Alessandra; Guido, Gianluca; Casagranda, Ivo

    2016-11-01

    The performance of 3 blood culture bottles (BACTEC Plus Aerobic/F, Plus Anaerobic/F, and Anaerobic Lytic/F) were analyzed with clinical specimens collected from 688 Emergency Department patients. A total of 270 strains belonging to 33 species were identified, with E. coli and S. aureus as the most frequently detected. Overall recovery rate (RR) of bacteria and yeast was equivalent in the Plus Aerobic/F vials (208 of 270 isolates; 77.0%) and Anaerobic Lytic/F vials (206 isolates; 76.3%) and significantly better than in the Plus Anaerobic/F vials (189 isolates; 70.0%). Median time to detection (TTD) was earliest with the Anaerobic Lytic/F vials (12.0h) compared with the Plus Aerobic/F (14.6h) and Plus Anaerobic/F vials (15.4h). Positivity rate (PR) was similar for Anaerobic Lytic/F vials (76.9%) and Plus Aerobic/F vials (76.5%), but better if compared with Plus Anaerobic/F vials (69.4%). The PR and TTD for the combination of Plus Aerobic/F with Anaerobic Lytic/F (94.5% and 12.3h, respectively) was significantly better than with Plus Aerobic/F with Plus Anaerobic/F (87.8% and 14.1h). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Time to Positivity and Detection of Growth in Anaerobic Blood Culture Vials Predict the Presence of Candida glabrata in Candidemia: a Two-Center European Cohort Study

    PubMed Central

    Kaasch, Achim J.; Soriano, Alex; Torres, Jorge-Luis; Vergara, Andrea; Morata, Laura; Zboromyrska, Yuliya; De La Calle, Cristina; Alejo, Izaskun; Hernández, Cristina; Cardozo, Celia; Marco, Franscesc; Del Río, Ana; Almela, Manel; Mensa, Josep; Martínez, José Antonio

    2014-01-01

    This study shows the accuracy of exclusive or earlier growth in anaerobic vials to predict Candida glabrata in a large series of candidemic patients from two European hospitals using the Bactec 9240 system. Alternatively, C. glabrata can be predicted by a time to positivity cutoff value, which should be determined for each setting. PMID:24899027

  18. Detection and Characteristics of Rifampicin-Resistant Isolates of Mycobacterium tuberculosis.

    PubMed

    Cherednichenko, A G; Dymova, M A; Solodilova, O A; Petrenko, T I; Prozorov, A I; Filipenko, M L

    2016-03-01

    Genotyping and analysis the drug resistance of 59 isolates of M. tuberculosis obtained from patients living in Altai Territory were performed using a BACTEC MGIT 960 fluorometric system by means of VNTR typing (variable number tandem repeat), PCR-RFLP analysis, and sequence analysis. The occurrence frequency was highest for isolates of the Beijing family (n=30, 50.8%). Analysis of mutation spectrum in the rpoB gene associated with rifampicin resistance revealed the major mutation (codon 531 of the rpoB gene) in 93% samples, which allows us to use rapid test systems.

  19. Auditing smear microscopy results according to time to detection using the BACTEC™ MGIT™ TB system.

    PubMed

    Elsaghier, A A F

    2015-09-01

    Smear microscopy is a rapid method for the identification of the most infectious patients with mycobacterial infection. Suboptimal smear microscopy may significantly compromise or delay patient isolation and contact tracing. A stringent method for auditing mycobacterial smear results is thus needed. This article proposes an auditing tool based on time to detection (TTD) of culture-positive samples using the automated BACTEC™ MGIT™ 960 TB system. In our study, sputum samples subjected to liquefaction and concentration before staining with a TTD of ≤ 13 days using the BACTEC system should be positive on smear microscopy.

  20. Direct identification by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) from positive blood culture bottles: An opportunity to customize growth conditions for fastidious organisms causing bloodstream infections.

    PubMed

    Sharma, Megha; Gautam, Vikas; Mahajan, Monika; Rana, Sudesh; Majumdar, Manasi; Ray, Pallab

    2017-10-01

    Culture-negative bacteraemia has been an enigmatic entity with respect to its aetiological agents. In an attempt to actively identify those positive blood cultures that escape isolation and detection on routine workflow, an additional step of MALDI-TOF MS (matrix-assisted laser desorption ionization-time of flight mass spectrometry) based detection was carried out directly from the flagged blood culture bottles. Blood samples from 200 blood culture bottles that beeped positive with automated (BACTEC) system and showed no growth of organism on routine culture media, were subjected to analysis by MALDI-TOF MS. Forty seven of the 200 (23.5%) bacterial aetiology could be established by bottle-based method. Based on these results, growth on culture medium could be achieved for the isolates by providing special growth conditions to the fastidious organisms. Direct identification by MALDI-TOF MS from BACTEC-positive bottles provided an opportunity to isolate those fastidious organisms that failed to grow on routine culture medium by providing them with necessary alterations in growth environment.

  1. Time to positivity and detection of growth in anaerobic blood culture vials predict the presence of Candida glabrata in candidemia: a two-center European cohort study.

    PubMed

    Cobos-Trigueros, Nazaret; Kaasch, Achim J; Soriano, Alex; Torres, Jorge-Luis; Vergara, Andrea; Morata, Laura; Zboromyrska, Yuliya; De La Calle, Cristina; Alejo, Izaskun; Hernández, Cristina; Cardozo, Celia; Marco, Franscesc; Del Río, Ana; Almela, Manel; Mensa, Josep; Martínez, José Antonio

    2014-08-01

    This study shows the accuracy of exclusive or earlier growth in anaerobic vials to predict Candida glabrata in a large series of candidemic patients from two European hospitals using the Bactec 9240 system. Alternatively, C. glabrata can be predicted by a time to positivity cutoff value, which should be determined for each setting. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  2. Pseudoepidemic of Nocardia asteroides associated with a mycobacterial culture system.

    PubMed Central

    Patterson, J E; Chapin-Robertson, K; Waycott, S; Farrel, P; McGeer, A; McNeil, M M; Edberg, S C

    1992-01-01

    Nocardia isolations increased from 0.7 to 11.7/1,000 acid-fast bacillus and mycological cultures (P less than 0.000001). Only three isolations from one patient represented infection. Pseudoepidemic strain identity was confirmed by DNA fingerprinting; the isolate causing infection was distinct. The end of the pseudoepidemic was associated with changing the needle sterilizer and prolonging needle sterilization time on the BACTEC 460 machine. To our knowledge, this is the first reported Nocardia asteroides pseudoepidemic. Images PMID:1583150

  3. Evaluation of the BD Max StaphSR Assay for Rapid Identification of Staphylococcus aureus and Methicillin-Resistant S. aureus in Positive Blood Culture Broths

    PubMed Central

    Hofko, Marjeta; Hamilton, Fiona; Mackenzie, Laura; Zimmermann, Stefan; Templeton, Kate

    2015-01-01

    We evaluated the performance of the BD Max StaphSR assay for the direct detection of Staphylococcus aureus from blood culture medium. In a two-center trial, 155 blood cultures from the BD Bactec FX system and 212 from the bioMérieux BacT/Alert system were tested; 170 bottles yielded S. aureus, and all were identified correctly by the BD Max StaphSR assay. The assay required approximately 2.5 h, thus allowing rapid identification of blood cultures flagged positive. PMID:26292311

  4. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    PubMed

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  5. [Problems found in the isolation of mycelial fungi (Fusarium solani) from blood culture (Bacter NR-860)].

    PubMed

    Sanz, F; Soledad Cuétara, M; del Palacio, A; Campbell, C K; Johnson, L; Urruzunu, P; Pía Roiz, M

    1993-11-01

    F. solani fungemia is unusual. Patients at risk are immunosuppressed, have underlying malignancy or severe debilitating diseases. We report two cases of F. solani fungemia in two non neutropenic patients who had been treated with wide-spectrum antibiotics an/or systemic corticosteroids, parenteral nutrition and intravenous lines. Bactec NR-860 (Becton-Dickinson) system was used, and growth was detected in aerobic conditions (between 3-7 days of incubation). Removal of the catheters with or without i.v. amphotericin B were used successfully. The spectrum of Fusarium sp. fungemia is discussed. Current available antifungal therapy is also reviewed.

  6. Comparison of the detection of periodontal pathogens in bacteraemia after tooth brushing by culture and molecular techniques.

    PubMed

    Marín, M-J; Figuero, E; González, I; O'Connor, A; Diz, P; Álvarez, M; Herrera, D; Sanz, M

    2016-05-01

    The prevalence and amounts of periodontal pathogens detected in bacteraemia samples after tooth brushing-induced by means of four diagnostic technique, three based on culture and one in a molecular-based technique, have been compared in this study. Blood samples were collected from thirty-six subjects with different periodontal status (17 were healthy, 10 with gingivitis and 9 with periodontitis) at baseline and 2 minutes after tooth brushing. Each sample was analyzed by three culture-based methods [direct anaerobic culturing (DAC), hemo-culture (BACTEC), and lysis-centrifugation (LC)] and one molecular-based technique [quantitative polymerase chain reaction (qPCR)]. With culture any bacterial isolate was detected and quantified, while with qPCR only Porphyromonas gingivalis and Aggregatibacter actinomycetemcomitans were detected and quantified. Descriptive analyses, ANOVA and Chi-squared tests, were performed. Neither BACTEC nor qPCR detected any type of bacteria in the blood samples. Only LC (2.7%) and DAC (8.3%) detected bacteraemia, although not in the same patients. Fusobacterium nucleatum was the most frequently detected bacterial species. The disparity in the results when the same samples were analyzed with four different microbiological detection methods highlights the need for a proper validation of the methodology to detect periodontal pathogens in bacteraemia samples, mainly when the presence of periodontal pathogens in blood samples after tooth brushing was very seldom.

  7. Impact of Implementation of an Automated Liquid Culture System on Diagnosis of Tuberculous Pleurisy.

    PubMed

    Lee, Byung Hee; Yoon, Seong Hoon; Yeo, Hye Ju; Kim, Dong Wan; Lee, Seung Eun; Cho, Woo Hyun; Lee, Su Jin; Kim, Yun Seong; Jeon, Doosoo

    2015-07-01

    This study was conducted to evaluate the impact of implementation of an automated liquid culture system on the diagnosis of tuberculous pleurisy in an HIV-uninfected patient population. We retrospectively compared the culture yield, time to positivity, and contamination rate of pleural effusion samples in the BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT) and Ogawa media among patients with tuberculous pleurisy. Out of 104 effusion samples, 43 (41.3%) were culture positive on either the MGIT or the Ogawa media. The culture yield of MGIT was higher (40.4%, 42/104) than that of Ogawa media (18.3%, 19/104) (P<0.001). One of the samples was positive only on the Ogawa medium. The median time to positivity was faster in the MGIT (18 days, range 8-32 days) than in the Ogawa media (37 days, range 20-59 days) (P<0.001). No contamination or growth of nontuberculous mycobacterium was observed on either of the culture media. In conclusion, the automated liquid culture system could provide approximately twice as high yields and fast results in effusion culture, compared to solid media. Supplemental solid media may have a limited impact on maximizing sensitivity in effusion culture; however, further studies are required.

  8. A dedicated fungal culture medium is useful in the diagnosis of fungemia: a retrospective cross-sectional study.

    PubMed

    Zheng, Shuwei; Ng, Tong Yong; Li, Huihua; Tan, Ai Ling; Tan, Thuan Tong; Tan, Ban Hock

    2016-01-01

    Mortality for candidemia ranges from 15% to 35%. Current guidelines recommend inoculating blood into three aerobic and three anaerobic blood culture bottles when candidemia is suspected, without mention of a fungal blood culture bottle. To determine the value of the BACTEC Myco/F Lytic blood culture media in the diagnosis of fungemia. A two-year retrospective cross-sectional study was performed for patients who had fungemia with submitted BACTEC Plus Aerobic/F (Aer), BACTEC Plus Anaerobic/F (Anaer) or Myco/F Lytic (Myco) blood culture bottles. The detection rate of fungemia was 77.4% in 93 patients with contemporaneously submitted blood culture bottles when limited to only Aer/Anaer culture results. The detection rate improved significantly with the addition of the Myco culture bottle results (p<0.0001). A logistic regression model showed that Myco culture bottle submissions were less useful for patients with appropriate anti-fungal therapy administered within 48 hours [OR = 0.18, 95% CI = (0.06, 0.49), p = 0.001] and those with fungal growth detected within 48 hours [OR = 0.33, 95% CI = (0.12, 0.89), p = 0.001]. Among a subset of patients with concordant blood culture results, those with Myco culture bottles submission allowed earlier fungal detection and speciation by at least one day in 27.5% and 25.0% of the cases respectively. Our study highlights the importance of a dedicated fungal blood culture when fungemia is clinically suspected. Nearly a quarter of fungemias may be missed if a fungal blood culture is not performed.

  9. Comparative efficacies of amoxicillin, clindamycin, and moxifloxacin in prevention of bacteremia following dental extractions.

    PubMed

    Diz Dios, P; Tomás Carmona, I; Limeres Posse, J; Medina Henríquez, J; Fernández Feijoo, J; Alvarez Fernández, M

    2006-09-01

    We evaluated the efficacies of oral prophylactic treatment with amoxicillin (AMX), clindamycin (CLI), and moxifloxacin (MXF) in the prevention of bacteremia following dental extractions (BDE). Two hundred twenty-one adults who required dental extractions under general anesthesia were randomly assigned to a control group, an AMX group, a CLI group, and an MXF group (the individuals in the drug treatment groups received 2 g, 600 mg, and 400 mg, respectively, 1 to 2 h before anesthesia induction). Venous blood samples were collected from each patient at the baseline and 30 s, 15 min, and 1 h after the dental extractions. The samples were inoculated into BACTEC Plus aerobic and anaerobic blood culture bottles and were processed in a BACTEC 9240 instrument. Subculture and the further identification of the isolated bacteria were performed by conventional microbiological techniques. The prevalences of BDE in the control group, AMX group, CLI group, and MXF group were 96, 46, 85, and 57%, respectively, at 30 s; 64, 11, 70, and 24%, respectively, at 15 min; and 20, 4, 22, and 7%, respectively, at 1 h. Streptococcus spp. were the most frequently identified bacteria in all groups (44 to 68%), with the lowest percentage being detected in the AMX group (44%). AMX and MXF prophylaxis showed high efficacies in reducing the prevalence and duration of BDE, but CLI prophylaxis was noneffective. As a consequence, MXF prophylaxis is a promising antibiotic alternative for the prevention of BDE when beta-lactams are not indicated.

  10. Comparative Efficacies of Amoxicillin, Clindamycin, and Moxifloxacin in Prevention of Bacteremia following Dental Extractions

    PubMed Central

    Diz Dios, P.; Tomás Carmona, I.; Limeres Posse, J.; Medina Henríquez, J.; Fernández Feijoo, J.; Álvarez Fernández, M.

    2006-01-01

    We evaluated the efficacies of oral prophylactic treatment with amoxicillin (AMX), clindamycin (CLI), and moxifloxacin (MXF) in the prevention of bacteremia following dental extractions (BDE). Two hundred twenty-one adults who required dental extractions under general anesthesia were randomly assigned to a control group, an AMX group, a CLI group, and an MXF group (the individuals in the drug treatment groups received 2 g, 600 mg, and 400 mg, respectively, 1 to 2 h before anesthesia induction). Venous blood samples were collected from each patient at the baseline and 30 s, 15 min, and 1 h after the dental extractions. The samples were inoculated into BACTEC Plus aerobic and anaerobic blood culture bottles and were processed in a BACTEC 9240 instrument. Subculture and the further identification of the isolated bacteria were performed by conventional microbiological techniques. The prevalences of BDE in the control group, AMX group, CLI group, and MXF group were 96, 46, 85, and 57%, respectively, at 30 s; 64, 11, 70, and 24%, respectively, at 15 min; and 20, 4, 22, and 7%, respectively, at 1 h. Streptococcus spp. were the most frequently identified bacteria in all groups (44 to 68%), with the lowest percentage being detected in the AMX group (44%). AMX and MXF prophylaxis showed high efficacies in reducing the prevalence and duration of BDE, but CLI prophylaxis was noneffective. As a consequence, MXF prophylaxis is a promising antibiotic alternative for the prevention of BDE when beta-lactams are not indicated. PMID:16940094

  11. The Importance of Mean Neutrophil Volume (MNV) Values in Differential Diagnosis of Bacterial Sepsis.

    PubMed

    Şafak, Birol; Baykan, Özgür; Kılınç, Osman; Özer Yıldırım, Diğdem

    2017-01-01

    Bloodstream infections are a significant cause of morbidity and mortality in hospitalized patients. Blood cultures and other laboratory tests are used for diagnosis. Among these tests, the mean neutrophil volume (MNV) value is reported as a potential indicator that supports the diagnosis of sepsis. Our study identified the MNV values of patients via microorganisms cultivated from blood cultures and examined the role of these MNV values in the early diagnosis of bloodstream infections. Our study surveyed retrospectively 148 adult patient blood culture samples that had been sent to our laboratory. BACTEC 9050 (Becton Dickinson, USA) and BACTEC FX 40 (Becton Dickinson, USA) devices were used in the blood culture isolation procedures. The average MNV value was found to be 159.0 (+11.3) in patients whose sepsis originated from Gram-negative bacteria, and the average MNV value was measured as 152.4 (+14.5) among patients whose sepsis originated from Gram-positive bacteria. When comparing groups of patients having Gram-negative bacteria and patients having Gram-positive bacteria, a statistically significant difference (p = 0.041) in the MNV values was observed. The MNV value was found to be statistically significant in discrimination of Gram-negative and Gram-positive sepsis. Considering these findings, measuring the MNV values can help initiate proper antibiotic treatment more quickly, and we think that this will help lower the mortality rate. However, these findings should be supported with further studies. Copyright © 2017 National Medical Association. Published by Elsevier Inc. All rights reserved.

  12. [Blood stream infection and blood culture--"progress" and "blind" in blood culture testing].

    PubMed

    Kobayashi, Intetsu

    2005-04-01

    We have investigated various types of blood culture bottles which are mainly used at present and posed problems present in the blood culture bottles. First, there are differences between resin and ecosorb in the ability to adsorb and inactivate antibiotics in the blood. Second, the delay in placing the bottle (into which blood was inoculated) to the automatic instrument (delay in the start of incubation) greatly affects the automatic detection by BACTEC system and shows false negatives. Third, when the same blood is incubated in plural bottles (aerobic and anaerobic bottles), the differences among the detected organisms in the number are comparatively high, i.e., about 40%. In addition, there are differences among the organisms in the number of days required for the detection of the organisms. In this case, the detected organisms are clearly different in many cases. The technology of blood culture has been progressed remarkably. However, the efficiency of utilization of automatic instruments for diagnosis of infection depends greatly on the ability of laboratory technicians.

  13. Current trends of microorganisms and their sensitivity pattern in paediatric septic arthritis: A prospective study from tertiary care level hospital.

    PubMed

    Motwani, Girish; Mehta, Rujuta; Aroojis, Alaric; Vaidya, Sandeep

    2017-01-01

    Early treatment of septic arthritis is essential before irreversible damage to the articular cartilage occurs. Clinicians often start empirical antibiotic therapy for symptomatic relief while awaiting a definitive culture report. In present day parlance with variations in different centres in the private and public sector and rampant antibiotic abuse, a lot of resistance is being seen in the flora and their sensitivity patterns. Hence it is imperative to document and analyze these changing trends. The authors conducted a retrospective analysis of prospectively gathered data of 60 patients under 14 years of age. Joint arthrotomy was performed as a standard therapeutic protocol and the drained pus or synovial fluid was sent for gram stain and culture by 2 different methods: conventional agar plate method and BACTEC Peds Plus/F bottle method. Antibiotic susceptibility tests were done by the disc diffusion method of Clinical Laboratory Standards Institute (CLSI). The commonest presenting age group was below 1 year (80% patients) including 24 neonates. There were 19 hospital and 41 community acquired cases of septic arthritis. The hip (56%) was the commonest affected joint followed by knee (28%), shoulder joint (11%) and elbow (5%). Microorganism was isolated in 53% isolates of joint fluid only (36 culture positive patients). Conventional agar methods of culture showed positive report in only 42% patients (15/36 patients) while with the BACTEC method the yield was 71%. In the Community acquired septic arthritis, methicillin sensitive Staphylococcus aureus was isolated as commonest microbe while resistant variety of gram negative bacilli including E. coli and Klebsiella were found as predominant organism causing hospital acquired nosocomial infection of joints. The results strikingly differ in terms of response to treatment as most patients (11/19 patients) showed significant resistance to the most commonly practiced empirical antibiotic regimen of ampicillin-cloxacillin group in routine practice. When cefazolin was used as empirical antibiotic, it has shown good response and better sensitivity in 82% patients (27/33 patients). S. aureus is still the most common organism in septic arthritis. The BACTEC system was found to improve the yield of clinically significant isolates. Though a significant resistance to common antibiotic regimen is noticed, the strain is susceptible to cephalosporin group of antibiotics. We recommend the use of cephalosporine antibiotics as an empirical therapy till culture and sensitivity report are available.

  14. Changing patterns and trends of multidrug-resistant tuberculosis at referral centre in Northern India: a 4-year experience.

    PubMed

    Maurya, A K; Singh, A K; Kumar, M; Umrao, J; Kant, S; Nag, V L; Kushwaha, R A S; Dhole, T N

    2013-01-01

    India has a high burden of drug-resistant tuberculosis (TB), although there is little data on multidrug-resistant tuberculosis (MDR-TB). Although MDR-TB has existed for long time in India, very few diagnostic laboratories are well-equipped to test drug sensitivity. The objectives of this study were to determine the prevalence of MDR-TB, first-line drug resistance patterns and its changing trends in northern India in the 4 years. This was a prospective study from July 2007 to December 2010. Microscopy, culture by Bactec460 and p-nitro-α-acetylamino-β-hydroxypropiophenone (NAP) test was performed to isolate and identify Mycobacterium tuberculosis (M. tb) complex (MTBC). Drug sensitivity testing (DST) was performed by 1% proportional method (Bactec460) for four drugs: Rifampicin, isoniazid, ethambutol and streptomycin. Various clinical and demographical profiles were evaluated to analyse risk factors for development of drug resistance. We found the overall prevalence rate of MDR-TB to be 38.8%, increasing from 36.4% in 2007 to 40.8% in 2010. we found that the prevalence of MDR-TB in new and previously treated cases was 29.1% and 43.3% ( P < 0.05; CI 95%). The increasing trend of MDR-TB was more likely in pulmonary TB when compared with extra-pulmonary TB ( P < 0.05; CI 95%). we found a high prevalence (38.8%) of MDR-TB both in new cases (29.1%) and previously treated cases (43.3%).This study strongly highlights the need to make strategies for testing, surveillance, monitoring and management of such drug-resistant cases.

  15. Phenotypic and genotypic characteristics of drug resistance in Mycobacterium tuberculosis isolates from pediatric population of Chennai, India.

    PubMed

    Therese, K Lily; Gayathri, R; Balasubramanian, S; Natrajan, S; Madhavan, H N

    2012-01-01

    Multidrug-resistant TB (MDR-TB) has been reported in almost all parts of the world. Childhood TB is accorded low priority by national TB control programs. Probable reasons include diagnostic difficulties, limited resources, misplaced faith in BCG and lack of data on treatment. Good data on the burden of all forms of TB among children in India are not available. To study the drug sensitivity pattern of tuberculosis in children aged from 3 months to 18 years and the outcome of drug-resistant tuberculosis by BACTEC culture system and PCR-based DNA sequencing technique. This is a retrospective study. One hundred and fifty-nine clinical specimens were processed for Ziehl-Neelsen stain, Mycobacterial culture by BACTEC method, phenotypic DST for first-line drugs for Mycobacterium tuberculosis (M. tuberculosis) isolates and PCR-based DNA sequencing was performed for the M. tuberculosis isolates targeting rpoB, katG, inhA, oxyR-ahpC, rpsL, rrs and pncA. Out of the 159 Mycobacterial cultures performed during the study period, 17 clinical specimens (10.7%) were culture positive for M. tuberculosis. Among the 17 M. tuberculosis isolates, 2 were multidrug-resistant TB. PCR-based DNA sequencing revealed the presence of many novel mutations targeting katG, inhA, oxyR-ahpC and pncA and the most commonly reported mutation Ser531Leu in the rpoB gene. This study underlines the urgent need to take efforts to develop methods for rapid detection and drug susceptibility of tubercle bacilli in the pediatric population.

  16. Chemical decontamination with N-acetyl-L-cysteine-sodium hydroxide improves recovery of viable Mycobacterium avium subsp. paratuberculosis organisms from cultured milk.

    PubMed

    Bradner, L; Robbe-Austerman, S; Beitz, D C; Stabel, J R

    2013-07-01

    Mycobacterium avium subsp. paratuberculosis is shed into the milk and feces of cows with advanced Johne's disease, allowing the transmission of M. avium subsp. paratuberculosis between animals. The objective of this study was to formulate an optimized protocol for the isolation of M. avium subsp. paratuberculosis in milk. The parameters investigated included chemical decontamination with N-acetyl-l-cysteine-sodium hydroxide (NALC-NaOH), alone and in combination with antibiotics (vancomycin, amphotericin B, and nalidixic acid), and the efficacy of solid (Herrold's egg yolk medium [HEY]) and liquid (Bactec 12B and para-JEM) culture media. For each experiment, raw milk samples from a known noninfected cow were inoculated with 10(2) to 10(8) CFU/ml of live M. avium subsp. paratuberculosis organisms. The results indicate that an increased length of exposure to NALC-NaOH from 5 to 30 min and an increased concentration of NaOH from 0.5 to 2.0% did not affect the viability of M. avium subsp. paratuberculosis. Additional treatment of milk samples with the antibiotics following NALC-NaOH treatment decreased the recovery of viable M. avium subsp. paratuberculosis cells more than treatment with NALC-NaOH alone. The Bactec 12B medium was the superior medium of the three evaluated for the isolation of M. avium subsp. paratuberculosis from milk, as it achieved the lowest threshold of detection. The optimal conditions for NALC-NaOH decontamination were determined to be exposure to 1.50% NaOH for 15 min followed by culture in Bactec 12B medium. This study demonstrates that chemical decontamination with NALC-NaOH resulted in a greater recovery of viable M. avium subsp. paratuberculosis cells from milk than from samples treated with hexadecylpyridinium chloride (HPC). Therefore, it is important to optimize milk decontamination protocols to ensure that low concentrations of M. avium subsp. paratuberculosis can be detected.

  17. Antitubercular activity of pentacyclic triterpenoids from plants of Argentina and Chile.

    PubMed

    Wächter, G A; Valcic, S; Flagg, M L; Franzblau, S G; Montenegro, G; Suarez, E; Timmermann, B N

    1999-11-01

    Screening of plants from South America for antitubercular activity and subsequent assay-guided fractionation resulted in the isolation and characterization of several pentacyclic triterpenoids. The MIC values of 22 triterpenoids were determined using the radiorespiratory BACTEC assay and range from 8 microM to above 128 microM. The structure-activity relationships are discussed.

  18. Identification and Susceptibility Testing of Enterobacteriaceae and Pseudomonas aeruginosa by Direct Inoculation from Positive BACTEC Blood Culture Bottles into Vitek 2

    PubMed Central

    Bruins, Marjan J.; Bloembergen, Peter; Ruijs, Gijs J. H. M.; Wolfhagen, Maurice J. H. M.

    2004-01-01

    Inoculation of an automated system for rapid identification (ID) and antimicrobial susceptibility testing (AST) directly from positive blood culture bottles will reduce the turnaround time of laboratory diagnosis of septicemic patients, which benefits clinical outcome and decreases patient costs. Direct test results, however, must always be confirmed by testing a pure overnight culture, which is the “gold standard.” We studied the accuracy of direct testing versus repeat testing in order to investigate the possibility of refraining from repeat testing. We also assessed the clinical risk of reporting results based on direct testing only. We inoculated Vitek 2 (bioMérieux) directly from 410 positive BACTEC 9240 (BD) blood culture bottles containing gram-negative rods and studied the ID and AST results. In a comparison of direct inoculation with the standard method, a total of 344 isolates of Enterobacteriaceae and Pseudomonas aeruginosa were tested, and 93.0% were correctly identified. Of the 39 (10.2%) samples that contained bacilli not identifiable by Vitek 2, only 1 gave a conclusive, correct result. The overall MIC agreement among 312 isolates was 99.2%, with 0.8% very major and 0.02% major error rates. Of only three (polymicrobial) samples, the direct susceptibility pattern would be reported to the clinician as too sensitive. Vitek 2 results obtained from direct inoculation of blood culture bottles containing gram-negative bacilli are safe enough for immediate reporting, provided that ID and AST are consistent. Repeat testing is not necessary, unless Gram stain or overnight subculture results raise doubt about the purity of the culture. PMID:14715724

  19. [Streptomycin as second-line chemotherapy for tuberculosis].

    PubMed

    Ruiz, P; Rodríguez-Cano, F; Zerolo, F J; Casal, M

    2003-06-01

    Streptomycin was the first antibiotic to be used against Mycobacterium tuberculosis. It was used for years in monotherapy regimens, thereby resulting in the appearance of resistance and the relegation of its use. The resistance detected against drugs currently employed has led to a renewed interest in streptomycin. Its mechanism of action is centered on the ribosome, inhibiting the protein synthesis of the microbacteria. Resistance appears when mutations in the genes codifying for rRNA 16S and for protein S12 are produced. We studied the use of streptomycin against 899 M. tuberculosis strains, 713 of which were from pulmonary and 186 from extrapulmonary isolates. The BACTEC 460 TB system was initially employed as was the ESP II system. As controls, the ATCC27294 pattern strains (susceptible to streptomycin, rifampicin, ethambutol and isoniazid) were used. The results showed 2.1% secondary resistance in all the cases. Multiresistance was observed in 12 strains.

  20. Direct detection of methicillin resistance in Staphylococcus aureus in blood culture broth by use of a penicillin binding protein 2a latex agglutination test.

    PubMed

    Qian, Qinfang; Venkataraman, Lata; Kirby, James E; Gold, Howard S; Yamazumi, Toshiaki

    2010-04-01

    We studied the utility of performing a penicillin binding protein 2a latex agglutination (PBP-LA) assay directly on Bactec blood culture broth samples containing Staphylococcus aureus to rapidly detect methicillin resistance. The sensitivity, specificity, positive predictive value, and negative predictive value of this method were 94.1%, 97.5%, 98%, and 92.9%, respectively.

  1. Multicenter evaluation of the Sepsityper™ extraction kit and MALDI-TOF MS for direct identification of positive blood culture isolates using the BD BACTEC™ FX and VersaTREK(®) diagnostic blood culture systems.

    PubMed

    Schieffer, K M; Tan, K E; Stamper, P D; Somogyi, A; Andrea, S B; Wakefield, T; Romagnoli, M; Chapin, K C; Wolk, D M; Carroll, K C

    2014-04-01

    (i) Evaluation of delayed time to blood culture extraction by the Sepsityper kit and impact of shipping pellets off-site for MALDI-TOF MS analysis. (ii) Comparison of Sepsityper and laboratory-developed extraction methods from a literature review. Using two blood culture systems (BD BACTEC and VersaTREK), we extracted 411 positive blood cultures using the Sepsityper kit to mimic a potential protocol for institutions without a MALDI-TOF MS. Extracted pellets were shipped and analysed on the Bruker UltraflexIII. Successful extraction of 358 (87·1%) samples was determined by the presence of detectable proteins. MALDI-TOF MS correctly identified 332 (80·8%) samples. Delayed time to extraction did not affect Sepsityper extraction or MALDI-TOF MS accuracy. The extracted pellets remain stable and provide accurate results by MALDI-TOF MS when shipped at room temperature to off-site reference laboratories. This is the first study to show that institutions without a MALDI-TOF MS can take advantage of this innovative technology by shipping a volume of blood to an off-site laboratory for extraction and MALDI-TOF MS analysis. We also performed a literature review to compare various extraction methods. © 2014 The Society for Applied Microbiology.

  2. Bactericidal activity of OPC-67683 against drug-tolerant Mycobacterium tuberculosis.

    PubMed

    Saliu, Oluwabunmi Y; Crismale, Catina; Schwander, Stephan K; Wallis, Robert S

    2007-11-01

    There is an urgent need for drugs that hasten sterilization in tuberculosis; however, we presently lack indicators of this activity to guide early drug development. We previously described a novel in vitro assay to study mycobacterial phenotypic drug tolerance, in which sterilizing activity could be assessed. OPC-67,683 is a novel imidazooxazole that accelerates sterilization in the mouse tuberculosis model. The present study was conducted to determine the activity of OPC-67,683 in the in vitro tolerance model using drug-tolerant clinical Mycobacterium tuberculosis strains. Tolerance was assessed in Bactec radiometric culture as: (i) delayed decline in growth index during 14 days of drug exposure; (ii) shorter time to positivity of subcultures following drug exposure. Four isolates were selected from among 16 surveyed, based on delayed killing by isoniazid and OPC-67,683. Unlike isoniazid and rifampicin, whose rates of killing were concentration-independent, OPC-67,683 showed concentration-dependent effects that, at the highest dose levels tested (1.0 microg/mL), were superior to isoniazid and equal to rifampicin. The sterilizing activity of OPC-67683 against drug-tolerant M. tuberculosis in the Bactec model is consistent with its activity in mice. Further studies are warranted to examine the effects of OPC-67683 on mycobacterial persistence in tuberculous patients and to determine the biological basis of tolerance in the model.

  3. CHROMagar Candida Medium for Direct Susceptibility Testing of Yeast from Blood Cultures

    PubMed Central

    Tan, Grace L.; Peterson, Ellena M.

    2005-01-01

    An evaluation was performed on 95 blood cultures positive for Candida spp. to determine the correlation of direct susceptibility testing of fluconazole versus both standardized disk diffusion and MIC methods. For direct testing, an aliquot taken from BD BACTEC Plus and/or BD BACTEC Lytic/10 bottles (Becton Dickinson [BD], Sparks, MD) positive by gram stain for yeast was subcultured to CHROMagar Candida (BD), and a 25-μg fluconazole disk (BD) was placed on the plate. The area of growth inhibition surrounding the disk was measured at 24 and 48 h. In addition, a subculture of the isolate was tested by a microdilution MIC using YeastOne (TREK Diagnostics Systems Inc., OH) and disk diffusion (NCCLS M44-A) using a standardized inoculum plated onto CHROMagar Candida as well as Mueller-Hinton agar to which 2% glucose and 0.5 μg/ml methylene blue dye was added (MH-GMB). The categorical interpretation derived from the MIC was used as the reference to which the disk diffusion results were compared. There were a total of 41 Candida albicans, 23 Candida glabrata, 20 Candida parapsilosis, 9 Candida tropicalis, and 1 each of Candida krusei and Candida lusitaniae tested. At 24 h there was full agreement among the methods for all C. albicans, C. tropicalis, C. lusitaniae, and C. krusei isolates. For the C. parapsilosis isolates at 24 h there was one very major discrepancy using the direct CHROMagar and one major error with the standardized MH-GMB. The majority of the errors were seen at 24 h with the C. glabrata isolates. Of the 23 C. glabrata isolates at 24 h by direct CHROMagar, there were 10 minor and 1 very major error; by MH-GMB there were 12 minor and 2 very major errors; and by standardized CHROMagar Candida there were 13 minor and 2 major errors. There were no very major errors with C. glabrata when all plates were read at 48 h. At 24 h by the direct and standardized CHROMagar the majority of C. glabrata isolates were more resistant, whereas by MH-GMB they were more susceptible than the reference MIC interpretation. In summary, subculturing yeast directly from blood cultures onto CHROMagar to which a fluconazole disk has been added may provide a presumptive identification at 24 h and, with the exception of C. glabrata, was able to predict the susceptibility to fluconazole with the majority of Candida isolates examined in this evaluation. PMID:15814992

  4. The sensitivity of direct identification from positive BacT/ALERT™ (bioMérieux) blood culture bottles by matrix-assisted laser desorption ionization time-of-flight mass spectrometry is low.

    PubMed

    Szabados, F; Michels, M; Kaase, M; Gatermann, S

    2011-02-01

    Recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been presented as a novel method for the direct identification of bacteria from positive blood culture bottles. The rate of the MALDI TOF MS-based identification in the present study from positive BacT/ALERT (bioMérieux, Marcy l'Etoile, France) blood culture bottles was 30%, which is far below the previously reported sensitivities using the BACTEC (Becton Dickinson, Franklin Lakes, NJ, USA) system. We also found evidence that the Biotyper algorithm did not identify a second pathogen in cases of positive BacT/ALERT blood culture bottles containing two different species. © 2010 The Authors. Journal Compilation © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  5. A quantitative method to evaluate the donor corneal tissue quality used in a comparative study between two hypothermic preservation media.

    PubMed

    Parekh, Mohit; Salvalaio, Gianni; Ferrari, Stefano; Amoureux, Marie-Claude; Albrecht, Cecile; Fortier, Denis; Ponzin, Diego

    2014-12-01

    To standardize a new evaluation technique for calculating the overall quality (OQ) of the donor cornea and validate it using a comparative study of corneas preserved in Optisol-GS and Cornea Cold®. Thirty pairs of donor corneas were selected for a 4 week in vitro comparative study using masked observers. Physiological parameters like thickness, transparency, viable endothelial cell density (VECD) and morphology were transformed to numerical range (0-4) to obtain the OQ. Microbiological examination was performed using Bactec instrument. Students t test showed statistically better results (p < 0.05) from week 3 for thickness, week 2 for transparency and week 1 for morphology and VECD; statistical significance (p < 0.05) was found for OQ from week 2 for the corneas preserved in Cornea Cold® compared to Optisol-GS. Epithelial quality was similar regardless of the medium. Microbiological examination showed absence of aerobic and anaerobic microorganisms in both media. OQ method is efficient, consistent and easy, now validated for comparative studies. Further refinement is necessary for its use at eye-banks, bio-banks and research or transplantation purposes. Cornea Cold® is a promising hypothermic corneal storage medium with preservation time ≤21 days. This permits higher flexibility, evaluation accuracy, longer duration for surgical preparation and ease of transportation.

  6. FACTORS ASSOCIATED WITH ODONTOGENIC BACTERAEMIA IN ORTHODONTIC PATIENTS.

    PubMed

    Umeh, O D; Sanu, O O; Utomi, I L; Nwaokorie, F O

    2016-01-01

    Various researches have investigated factors associated with the prevalence and intensity of bacteraemia following oral procedures including orthodontic procedures. The aim of this study was to determine the effect of age, gender, plaque and gingival indices on the occurrence of odontogenic bacteraemia following orthodontic treatment procedures. Orthodontic Clinic, Lagos University Teaching Hospital (LUTH), Lagos , Nigeria. Using the consecutive, convenience sampling method, a total of 100 subjects who met the inclusion criteria were recruited for the study and peripheral blood was collected before and again within 2 minutes of completion of orthodontic procedures for microbiologic analysis using the BACTEC automated blood culture system and the lysis filtration methods of blood culturing. The subjects were randomly placed in one of four orthodontic procedures investigated: alginate impression making (Group I), separator placement (Group II), band cementation (Group III) and arch wire change (Group IV). Plaque and gingival indices were assessed using the plaque component of the Simplified Oral Hygiene Index (OHI-S) (Greene & Vermillion) and Modified gingival index (Lobene) respectively before blood collection. Spearman Point bi-serial correlations and logistic regression statistics were used for statistical evaluations at p < 0.05 level. An overall baseline prevalence of bacteraemia of 3% and 17% were observed using the BACCTEC and lysis filtration methods respectively. Similarly, overall prevalence of bacteraemia following orthodontic treatment procedures of 16% and 28% were observed respectively using the BACTEC and lysis filtration methods. A statistically significant increase in the prevalence of bateraemia was observed following separator placement (p=0.016). An increase in age, plaque index scores and modified gingival index scores of the subjects were found to be associated with an increase in the prevalence of bacteraemia following orthodontic treatment procedures, with plaque index score showing the strongest correlation. Separator placement was found to induce significantly highest level of bacteraemia. Meticulous oral hygiene practice and the use of 0.2% chlorhexidine mouth rinse prior to separator placement may be considered an effective measure in reducing oral bacteria load and consequent reduction of the occurrence of bacteraemia following orthodontic treatment procedures.

  7. Optimisation of decontamination method and influence of culture media on the recovery of Mycobacterium avium subspecies paratuberculosis from spiked water sediments.

    PubMed

    Aboagye, G; Rowe, M T

    2018-07-01

    The recovery of Mycobacterium avium subspecies paratuberculosis (Map) from the environment can be a laborious process - owing to Map being fastidious, its low number, and also high numbers of other microbial populations in such settings. Protocols i.e. filtration, decontamination and modified elution were devised to recover Map from spiked water sediments. Three culture media: Herrold's Egg Yolk Media (HEYM), Middlebrook 7H10 (M-7H10) and Bactec 12B were then employed to grow the organism following its elution. In the sterile sediment samples the recovery of Map was significant between the time of exposure for each of HEYM and M-7H10, and insignificant between both media (P < 0.05). However, in the non-sterile sediment samples, the HEYM grew other background microflora including moulds at all the times of exposure whilst 4 h followed by M-7H10 culture yielded Map colonies without any background microflora. Using sterile samples only for the Bactec 12B, the recovery of Map decreased as time of exposure increased. Based on these findings, M-7H10 should be considered for the recovery of Map from the natural environment including water sediments where the recovery of diverse microbial species remains a challenge. Map is a robust pathogen that abides in the environment. In water treatment operations, Map associates with floccules and other particulate matter including sediments. It is also a fastidious organism, and its detection and recovery from the water environment is a laborious process and can be misleading within the abundance of other mycobacterial species owing to their close resemblance in phylogenetic traits. In the absence of a reliable recovery method, Map continues to pose public health risks through biofilm in household water tanks, hence the need for the development of a reliable recovery protocol to monitor the presence of Map in water systems in order to curtail its public health risks. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Antimicrobial susceptibility testing of Mycobacterium tuberculosis complex for first and second line drugs by broth dilution in a microtiter plate format.

    PubMed

    Hall, Leslie; Jude, Kurt P; Clark, Shirley L; Wengenack, Nancy L

    2011-06-24

    The rapid detection of antimicrobial resistance is important in the effort to control the increase in resistant Mycobacterium tuberculosis (Mtb). Antimicrobial susceptibility testing (AST) of Mtb has traditionally been performed by the agar method of proportion or by macrobroth testing on an instrument such as the BACTEC (Becton Dickinson, Sparks, MD), VersaTREK (TREK Diagnostics, Cleveland, OH) or BacT/ALERT (bioMérieux, Hazelwood, MO). The agar proportion method, while considered the "gold" standard of AST, is labor intensive and requires calculation of resistance by performing colony counts on drug-containing agar as compared to drug-free agar. If there is ≥1% growth on the drug-containing medium as compared to drug-free medium, the organism is considered resistant to that drug. The macrobroth methods require instrumentation and test break point ("critical") drug concentrations for the first line drugs (isoniazid, ethambutol, rifampin, and pyrazinamide). The method described here is commercially available in a 96 well microtiter plate format [MYCOTB (TREK Diagnostics)] and contains increasing concentrations of 12 antimicrobials used for treatment of tuberculosis including both first (isoniazid, rifampin, ethambutol) and second line drugs (amikacin, cycloserine, ethionamide, kanamycin, moxifloxacin, ofloxacin, para-aminosalicylic acid, rifabutin, and streptomycin). Pyrazinamide, a first line drug, is not included in the microtiter plate due to its need for acidic test conditions. Advantages of the microtiter system include both ease of set up and faster turn around time (14 days) compared with traditional agar proportion (21 days). In addition, the plate can be set up from inoculum prepared using either broth or solid medium. Since the microtiter plate format is new and since Mtb presents unique safety challenges in the laboratory, this protocol will describe how to safely setup, incubate and read the microtiter plate.

  9. Bacterial rapid identification with matrix assisted laser desorption/ionization time-of-flight mass spectrometry: development of an 'in-house method' and comparison with Bruker Sepsityper(®) kit.

    PubMed

    Frédéric Ric, S; Antoine, M; Bodson, A; Lissoir, B

    2015-10-01

    The objective of this study was to compare an in-house matrix-assisted laser desorption ionization with time of flight (MALDI-TOF) method and a commercial MALDI-TOF kit (Sepsityper(®) kit) for direct bacterial identification in positive blood cultures. We also evaluated the time saved and the cost associated with the rapid identification techniques. We used the BACTEC(®) automated system for detecting positive blood cultures. Direct identification using Sepsityper kit and the in-house method were compared with conventional identification by MALDI-TOF using pure bacterial culture on the solid phase. We also evaluated different cut-off scores for rapid bacterial identification. In total, 127 positive blood vials were selected. The rate of rapid identification with the MALDI Sepsityper kit was 25.2% with the standard cut-off and 33.9% with the enlarged cut-off, while the results for the in-house method were 44.1 and 61.4%, respectively. Error rates with the enlarged cut-off were 6.98 (n = 3) and 2.56% (n = 2) for Sepsityper and the in-house method, respectively. Identification rates were higher for gram-negative bacteria. Direct bacterial identification succeeded in supplying rapid identification of the causative organism in cases of sepsis. The time taken to obtain a result was nearly 24  hours shorter for the direct bacterial identification methods than for conventional MALDI-TOF on solid phase culture. Compared with the Sepsityper kit, the in-house method offered better results and fewer errors, was more cost-effective and easier to use.

  10. Anti-mycobacterium tuberculosis activity of polyherbal medicines used for the treatment of tuberculosis in Eastern Cape, South Africa.

    PubMed

    Famewo, Elizabeth B; Clarke, Anna M; Wiid, Ian; Ngwane, Andile; van Helden, Paul; Afolayan, Anthony J

    2017-09-01

    The emergence of drug-resistant strains of Mycobacterium tuberculosis has become a global public health problem. Polyherbal medicines offer great hope for developing alternative drugs for the treatment of tuberculosis. To evaluate the anti-tubercular activity of polyherbal medicines used for the treatment of tuberculosis. The remedies were screened against Mycobacterium tuberculosis H37Rv using Middlebrook 7H9 media and MGIT BACTEC 960 system. They were liquid preparations from King Williams Town site A (KWTa), King Williams Town site B (KWTb), King Williams Town site C (KWTc), Hogsback first site (HBfs), Hogsback second site (HBss), Hogsback third site (HBts), East London (EL), Alice (AL) and Fort Beaufort (FB). The susceptibility testing revealed that all the remedies contain anti-tubercular activity with KWTa, KWTb, KWTc, HBfs, HBts, AL and FB exhibiting more activity at a concentration below 25 µl/ml. Furthermore, MIC values exhibited inhibitory activity with the most active remedies from KWTa, HBfs and HBts at 1.562 µg/ml. However, isoniazid showed more inhibitory activity against M. tuberculosis at 0.05 µg/ml when compare to the polyherbal remedies. This study has indicated that these remedies could be potential sources of new anti-mycobacterial agents against M. tuberculosis . However, the activity of these preparations and their active principles still require in vivo study in order to assess their future as new anti-tuberculosis agents.

  11. Rapid diagnosis of pulmonary tuberculosis

    PubMed Central

    Sarmiento, José Mauricio Hernández; Restrepo, Natalia Builes; Mejía, Gloria Isabel; Zapata, Elsa; Restrepo, Mary Alejandra; Robledo, Jaime

    2014-01-01

    Introduction World Health Organization had estimated 9.4 million tuberculosis cases on 2009, with 1.7 million of deaths as consequence of treatment and diagnosis failures. Improving diagnostic methods for the rapid and timely detection of tuberculosis patients is critical to control the disease. The aim of this study was evaluating the accuracy of the cord factor detection on the solid medium Middlebrook 7H11 thin layer agar compared to the Lowenstein Jensen medium for the rapid tuberculosis diagnosis. Methods Patients with suspected tuberculosis were enrolled and their sputum samples were processed for direct smear and culture on Lowenstein Jensen and BACTEC MGIT 960, from which positive tubes were subcultured on Middlebrook 7H11 thin layer agar. Statistical analysis was performed comparing culture results from Lowenstein Jensen and the thin layer agar, and their corresponding average times for detecting Mycobacterium tuberculosis. The performance of cord factor detection was evaluated determining its sensitivity, specificity, positive and negative predictive value. Results 111 out of 260 patients were positive for M. tuberculosis by Lowenstein Jensen medium with an average time ± standard deviation for its detection of 22.3 ± 8.5 days. 115 patients were positive by the MGIT system identifying the cord factor by the Middlebrook 7H11 thin layer agar which average time ± standard deviation was 5.5 ± 2.6 days. Conclusion The cord factor detection by Middlebrook 7H11 thin layer agar allows early and accurate tuberculosis diagnosis during an average time of 5 days, making this rapid diagnosis particularly important in patients with negative sputum smear. PMID:25419279

  12. Rapid Identification of Laboratory Contamination with Mycobacterium tuberculosis Using Variable Number Tandem Repeat Analysis

    PubMed Central

    Gascoyne-Binzi, Deborah M.; Barlow, Rachael E. L.; Frothingham, Richard; Robinson, Grant; Collyns, Timothy A.; Gelletlie, Ruth; Hawkey, Peter M.

    2001-01-01

    Compared with solid media, broth-based mycobacterial culture systems have increased sensitivity but also have higher false-positive rates due to cross-contamination. Systematic strain typing is rarely undertaken because the techniques are technically demanding and the data are difficult to organize. Variable number tandem repeat (VNTR) analysis by PCR is rapid and reproducible. The digital profile is easily manipulated in a database. We undertook a retrospective study of Mycobacterium tuberculosis isolates collected over an 18-month period following the introduction of the BACTEC MGIT 960 system. VNTR allele profiles were determined with early positive broth cultures and entered into a database with the specimen processing date and other specimen data. We found 36 distinct VNTR profiles in cultures from 144 patients. Three common VNTR profiles accounted for 45% of true-positive cases. By combining VNTR results with specimen data, we identified nine cross-contamination incidents, six of which were previously unsuspected. These nine incidents resulted in 34 false-positive cultures for 29 patients. False-positive cultures were identified for three patients who had previously been culture positive for tuberculosis and were receiving treatment. Identification of cross-contamination incidents requires careful documentation of specimen data and good communication between clinical and laboratory staff. Automated broth culture systems should be supplemented with molecular analysis to identify cross-contamination events. VNTR analysis is reproducible and provides timely results when applied to early positive broth cultures. This method should ensure that patients are not placed on unnecessary tuberculosis therapy or that cases are not falsely identified as treatment failures. In addition, areas where existing procedures may be improved can be identified. PMID:11136751

  13. In vitro anti-mycobacterial activities of three species of Cola plant extracts (Sterculiaceae).

    PubMed

    Adeniyi, B A; Groves, M J; Gangadharam, P R J

    2004-05-01

    Extracts obtained from three Nigerian Sterculiaceae plants: Cola accuminata, C. nitida and C. milleni were screened for anti-mycobacterium properties using a slow growing Mycobacterium bovis ATCC 35738 (designated BCG Mexican and known to have some virulence in mouse and guinea pig) at 1000 microg/ml using the radiometric (BACTEC) method. The extracts were also tested against six fast growing ATCC strains of M. vaccae using the broth microdilution method. The methanol extracts from both leaves, stem bark and root bark of Cola accuminata and from the leaves and stem bark of C. nitida and C. milleni were not active at the highest concentration of 1000 microg/ml. Only the methanol extract of root bark for both C. nitida and C. milleni were found to be potent against both M. bovis and strains of M. vaccae. The minimum inhibitory concentration (MIC) of C. nitida against M. bovis is 125 microg/ml while the MIC of C. milleni against M. bovis is 62.5 microg/ml after at least 6 days of inhibition with growth index (GI) units lesser than or equal to the change in GI units inoculated with a 1/100 of the BACTEC inoculum for a control vial. The minimum inhibitory concentration of C. milleni against the six ATCC strain of M. vaccae ranged from 62.5 microg/ml to 250 microg/ml while for C. nitida ranged from 500 microg/ml to above 1000microg/ml. Evidently, C. milleni has the highest inhibitory activity against both M. bovis and strains of M. vaccae used. Rifampicin, the positive control used has strong activity against M. bovis at the tested concentration of 5 microg and 10 microg/ml and 4 to 8 microg/ml against the six strains of M. vaccae. Copyright 2004 John Wiley & Sons, Ltd.

  14. Pathogens causing blood stream infections and their drug susceptibility profile in immunocompromised patients.

    PubMed

    Fayyaz, Muhammad; Mirza, Irfan Ali; Ikram, Aamer; Hussain, Aamir; Ghafoor, Tahir; Shujat, Umer

    2013-12-01

    To determine the types of pathogens causing blood stream infections and their drug susceptibility profile in immunocompromised patients. Cross-sectional, observational study. Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi, from January to September 2012. Blood culture bottles received from immunocompromised patients were dealt by two methods, brain heart infusion (BHI) broth based manual method and automated BACTEC system. The samples yielding positive growth from either of two methods were further analyzed. The identification of isolates was done with the help of biochemical reactions and rapid tests. Antimicrobial susceptibility of the isolates was carried out as per recommendations of Clinical and Laboratory Standards Institute (CLSI). Out of the 938 blood culture specimens received from immunocompromised patients, 188 (20%) yielded positive growth. Out of these, 89 (47.3%) isolates were Gram positive and Gram negative each, while 10 (5.3%) isolates were fungi (Candida spp.). In case of Gram positive isolates, 75 (84.3%) were Staphylococcus spp. and 51 (67%) were Methicillin resistant. Amongst Gram negative group 49 (55.1%) isolates were of enterobacteriaceae family, while 40 (44.9%) were non-lactose fermenters (NLF). In vitro antimicrobial susceptibility of Staphylococci revealed 100% susceptibility to vancomycin and linezolid. The enterobacteriaceae isolates had better susceptibility against amikacin 85.7% compared to tigecycline 61.2% and imipenem 59.2%. For NLF, the in vitro efficacy of aminoglycosides was 72.5%. The frequency of Gram positive and Gram negative organisms causing blood stream infections in immunocompromised patients was equal. Vancomycin in case of Gram positive and amikacin for Gram negative organisms revealed better in vitro efficacy as compared to other antibiotics.

  15. Corynebacterium pilbarense sp. nov., a non-lipophilic corynebacterium isolated from a human ankle aspirate.

    PubMed

    Aravena-Roman, M; Spröer, C; Sträubler, B; Inglis, T; Yassin, A F

    2010-07-01

    A non-lipophilic coryneform bacterium isolated from an anaerobic Bactec bottle inoculated with an ankle aspirate from a male patient was characterized by phenotypic and molecular taxonomic methods. Chemotaxonomic investigations revealed the presence of short-chain mycolic acids in the cell wall of the bacterium, a feature consistent with members of the genus Corynebacterium. Comparative 16S rRNA gene sequence analysis demonstrated that the isolate displayed 92.0-99.0 % gene sequence similarity with members of the genus Corynebacterium, with Corynebacterium ureicelerivorans as the most closely related phylogenetic species (99.0 % gene sequence similarity). However, the isolate could be genomically separated from C. ureicelerivorans on the basis of DNA-DNA hybridization studies (39.5 % relatedness). Furthermore, the isolate could also be differentiated from C. ureicelerivorans and other species of the genus Corynebacterium on the basis of biochemical properties. Based on both phenotypic and phylogenetic evidence, it is proposed that this isolate be classified as representing a novel species, Corynebacterium pilbarense sp. nov. (type strain IMMIB WACC 658(T)=DSM 45350(T)=CCUG 57942(T)).

  16. Evaluation of whole blood IFNgamma test using PPD and recombinant antigen challenge for diagnosis of pulmonary and extra-pulmonary tuberculosis.

    PubMed

    Kalantri, Yatiraj; Hemvani, Nanda; Chitnis, D S

    2009-06-01

    Quantiferon TB gold (QFT-G) with recombinant antigen cocktail is well evaluated for diagnosis of pulmonary tuberculosis (PTB). However, diagnosis of extra-pulmonary tuberculosis (EPTB) is more difficult due to limitations of conventional techniques. This study compares recombinant antigens based QFT-G and low cost PPD based interferon test for the diagnosis of PTB and EPTB. IFNgamma release, with recombinant antigens and PPD, was assayed by ELISA from 140 cases of EPTB, 100 cases of PTB along with acid fast bacillus (AFB) detection, AFB culture on LJ and MGIT BACTEC. Sensitivity and specificity for QFT-G recombinant antigens was 84.29% and 96%, while for PPD based interferon was 70% and 84% for EPTB group. The sensitivity was far superior to AFB smear and culture for both the antigens. Nine samples were identified as non-tubercular mycobacteria (NTM) in the EPTB group and all were negative for QFT-G, but six of them were positive for PPD based test. Results of the study show that QFT-G using recombinant antigen is sensitive and specific for both PTB and EPTB diagnosis. The PPD based test is economic and offers comparable performance for PTB and EPTB diagnosis and also useful for diagnosis of NTM.

  17. Evaluation of GeneXpert MTB/RIF for detecting Mycobacterium tuberculosis in a hospital in China.

    PubMed

    Tang, Tingyu; Liu, Fang; Lu, Xiaoling; Huang, Qingdong

    2017-04-01

    Objective To evaluate the performance of GeneXpert MTB/RIF in diagnosing pulmonary tuberculosis (TB) in China. Methods This cross-sectional study included sputum specimens of 240 suspected TB cases. Specimens were examined by light microscopy for the presence of acid-fast bacilli, which were cultured by the BACTEC MGIT 960 (M960) system and detected by the GeneXpert MTB/RIF assay. The positive rate, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and average turnaround time of methods were evaluated. Results The positive rate was 36.6% (87/238) for the GeneXpert MTB/RIF assay and 34.0% (81/238) by M960 culture, with no significant difference between methods (χ 2  = 0.33, p > 0.05). According to culture results, sensitivity of the GeneXpert MTB/RIF assay was 84.0% (68/81), specificity was 87.8% (129/147), the PPV was 78.2% (68/87), and the NPV was 87.2% (129/148). The agreement for results between Gene Xpert MTB/RIF and the M960 system was 82.8% and the Kappa value was 0.73. Conclusion The GeneXpert MTB/RIF assay is a simple, rapid, and accurate test for detecting Mycobacterium tuberculosis in sputum specimens.

  18. The value of microscopic-observation drug susceptibility assay in the diagnosis of tuberculosis and detection of multidrug resistance.

    PubMed

    Sertel Şelale, Denİz; Uzun, Meltem

    2018-01-01

    Inexpensive, rapid, and reliable tests for detecting the presence and drug susceptibility of Mycobacterium tuberculosis complex (MTBC) are urgently needed to control the transmission of tuberculosis. In this study, we aimed to assess the accuracy and speed of the microscopic-observation drug susceptibility (MODS) assay in the identification of MTBC and detection of multidrug resistance. Sputum samples from patients suspected to have tuberculosis were simultaneously tested with MODS and conventional culture [Löwenstein-Jensen (LJ) culture, BACTEC MGIT™ 960 (MGIT) system], and drug susceptibility testing (MGIT system) methods. A total of 331 sputum samples were analyzed. Sensitivity and specificity of MODS assay for detection of MTBC strains were 96% and 98.8%, respectively. MODS assay detected multidrug resistant MTBC isolates with 92.3% sensitivity and 96.6% specificity. Median time to culture positivity was similar for MGIT (8 days) and MODS culture (8 days), but was significantly longer with LJ culture (20 days) (p < 0.0001 for both comparisons). Median time to availability of the susceptibility results was significantly (p < 0.0001) shorter with MODS assay (8 days) than MGIT system (20 days). In conclusion, MODS is an inexpensive and rapid test with good performance characteristics for direct diagnosis of tuberculosis and detection of multidrug resistance. © 2017 APMIS. Published by John Wiley & Sons Ltd.

  19. Intravenous amoxicillin/clavulanate for the prevention of bacteraemia following dental procedures: a randomized clinical trial.

    PubMed

    Limeres Posse, J; Álvarez Fernández, M; Fernández Feijoo, J; Medina Henríquez, J; Lockhart, P B; Chu, V H; Diz Dios, P

    2016-07-01

    Although controversy exists regarding the efficacy of antibiotic prophylaxis for patients at risk of infective endocarditis, expert committees continue to publish recommendations for antibiotic prophylaxis regimens. This study aimed to evaluate the efficacy of four antimicrobial regimens for the prevention of bacteraemia following dental extractions. The study population included 266 adults requiring dental extractions who were randomly assigned to the following five groups: control (no prophylaxis); 1000/200 mg of amoxicillin/clavulanate intravenously; 2 g of amoxicillin by mouth; 600 mg of clindamycin by mouth; and 600 mg of azithromycin by mouth. Venous blood samples were collected from each patient at baseline and at 30 s, 15 min and 1 h after dental extractions. Samples were inoculated into BACTEC Plus culture bottles and processed in the BACTEC 9240. Conventional microbiological techniques were used for subcultures and further identification of the isolated bacteria. The trial was registered at ClinicalTrials.gov with ID number NCT02115776. The incidence of bacteraemia in the control, amoxicillin/clavulanate, amoxicillin, clindamycin and azithromycin groups was: 96%, 0%, 50%, 87% and 81%, respectively, at 30 s; 65%, 0%, 10%, 65% and 49% at 15 min; and 18%, 0%, 4%, 19% and 18% at 1 h. Streptococci were the most frequently identified bacteria. The percentage of positive blood cultures at 30 s post-extraction was lower in the amoxicillin/clavulanate group than in the amoxicillin group (P < 0.001). The incidence of bacteraemia in the clindamycin group was similar to that in the control group. Bacteraemia following dental extractions was undetectable with amoxicillin/clavulanate prophylaxis. Alternative antimicrobial regimens should be sought for patients allergic to the β-lactams. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Mycobacteriosis due to Mycobacterium genavense in six pet birds.

    PubMed Central

    Hoop, R K; Böttger, E C; Ossent, P; Salfinger, M

    1993-01-01

    Six cases of mycobacteriosis due to Mycobacterium genavense in three budgerigars (Melopsittacus undulatus), one orange-winged amazon (Amazona amazonica), one flycatcher (Cyanoptila cyanomelana), and one zebra finch (Taeniopygia guttata) are discussed. Gross lesions associated with the infection included a high degree of muscular wasting (five cases), hepatomegaly (four cases), and thickening of the wall of the small intestine (four cases). Granulomas were found in the lung (one case) and the subcutis (one case). Acid-fast bacilli were detected in the liver of all six birds. Only the use of acidic BACTEC mediums consistently led to growth, whereas the egg-based medium failed. These findings point to a possible role of the environment as a reservoir for M. genavense. Images PMID:8463407

  1. Bacteremia following dental implant surgery: preliminary results.

    PubMed

    Bölükbaşı, Nilüfer; Özdemir, Tayfun; Öksüz, Lütfiye; Gürler, Nezahat

    2012-01-01

    The aims of this study were to investigate the incidence of bacteremia, bacteriology and antibiotic susceptibility against to causative bacteria associated with dental implant installation. 30 generally healthy patients were enrolled in this study. Blood samples were collected at baseline and at 30 minutes after dental implant installation and 24 hours after dental implant surgery. Blood samples were cultured in a BACTEC system. The isolated bacteria were identified using conventional methods. Antimicrobial sensitivity tests were performed by disc diffusion. No bacteria were isolated at the baseline and 24 hours after surgery, whereas the prevalence of bacteremia at 30 minutes after dental implant installation was 23%. The isolated bacteria species were Staphylococcus epidermidis, Eubacterium spp., Corynebacterium spp. and Streptococcus viridans. The Staphylococcus epidermidis, which was isolated in three patients, was found to be resistant to penicillin which is first choice of many clinicians. Our findings suggest that installation of dental implants can produce bacteremia. Within the limitations of this study, it can be speculated that the resistance of antibiotics may compromise the routine prophylaxis against infective endocarditis. Therefore use of blood cultures and antibiograms may be suggested in risky patients. The outcome of the present study should be verified using a larger patient group with varying conditions.

  2. Diagnostic usefulness of Xpert MTB/RIF assay for detection of tuberculous meningitis using cerebrospinal fluid.

    PubMed

    Rufai, Syed Beenish; Singh, Amit; Singh, Jitendra; Kumar, Parveen; Sankar, Manimuthu Mani; Singh, Sarman

    2017-08-01

    Tuberculous meningitis (TBM) is the most severe form of extra-pulmonary tuberculosis (TB) due to association of diseases with high rates of mortality and morbidity. Diagnosis continues to be a clinical challenge as microbiological confirmation is rare and time consuming resulting in delayed treatment. Xpert MTB/RIF assay is a rapid and simple test, which has been endorsed by World Health Organization as an initial diagnostic test for the diagnosis of TBM. However, evidence still lacks for its performance on cerebrospinal fluid (CSF) for the diagnosis of TBM especially from India. A total of 267 CSF samples from patients with high clinico-radiological suspicion of TBM were included in this study. Ziehl-Neelsen (ZN) staining, BACTEC Mycobacterial Growth Indicator Tube (MGIT-960) culture system, and Xpert MTB/RIF assay (using cartridge version G4) were tested on all samples. Of total 267 samples, all were negative for smear AFB and 52 (19.5%) were culture positive by MGIT-960 culture system. However, out of 52 (19.5%) cultures detected positive by MGIT-960, 5 (9.6%) were detected as resistant to rifampicin. Xpert MTB/RIF assay was positive in 38 (14.2%) samples and negative in 223 (83.5%) samples. Cartridge error was detected in 6 (2.2%) samples, which could not be repeated due to insufficient sample volume. The sensitivity and specificity of Xpert MTB/RIF assay in comparison to MGIT-960 was 55.1% (95%, CI: 40.2-69.3) and 94.8% (95%, CI: 90.9-97.4) respectively. Overall, Xpert MTB/RIF assay detected 38 (14.2%) as positive for MTB of which 4 (10.5%), 31 (81.6%) and 3 (7.9%) were found to be rifampicin resistant, sensitive and indeterminate respectively. Xpert MTB/RIF assay showed lower sensitivity as compared to MGIT 960 culture for the diagnosis of TBM from CSF samples. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  3. Development of a rapid and simplified protocol for direct bacterial identification from positive blood cultures by using matrix assisted laser desorption ionization time-of- flight mass spectrometry.

    PubMed

    Jakovljev, Aleksandra; Bergh, Kåre

    2015-11-06

    Bloodstream infections represent serious conditions carrying a high mortality and morbidity rate. Rapid identification of microorganisms and prompt institution of adequate antimicrobial therapy is of utmost importance for a successful outcome. Aiming at the development of a rapid, simplified and efficient protocol, we developed and compared two in-house preparatory methods for the direct identification of bacteria from positive blood culture flasks (BD BACTEC FX system) by using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI TOF MS). Both methods employed saponin and distilled water for erythrocyte lysis. In method A the cellular pellet was overlaid with formic acid on the MALDI TOF target plate for protein extraction, whereas in method B the pellet was exposed to formic acid followed by acetonitrile prior to placing on the target plate. Best results were obtained by method A. Direct identification was achieved for 81.9 % and 65.8 % (50.3 % and 26.2 % with scores >2.0) of organisms by method A and method B, respectively. Overall concordance with final identification was 100 % to genus and 97.9 % to species level. By applying a lower cut-off score value, the levels of identification obtained by method A and method B increased to 89.3 % and 77.8 % of organisms (81.9 % and 65.8 % identified with scores >1.7), respectively. Using the lowered score criteria, concordance with final results was obtained for 99.3 % of genus and 96.6 % of species identifications. The reliability of results, rapid performance (approximately 25 min) and applicability of in-house method A have contributed to implementation of this robust and cost-effective method in our laboratory.

  4. Pneumococcal septic arthritis in adults: clinical analysis and review.

    PubMed

    Belkhir, L; Rodriguez-Villalobos, H; Vandercam, B; Marot, J C; Cornu, O; Lambert, M; Yombi, J C

    2014-01-01

    Septic arthritis (SA) is a rheumatological emergency that can lead to rapid joint destruction and irreversible loss of function. The most common pathogen causing SA is Staphylococcus aureus which is responsible for 37-65% of cases. Streptococcus pneumoniae is traditionally described as an uncommon cause of SA of a native joint. The objective of our study was to analyse clinical characteristics, treatment, and outcome of all cases of pneumococcal septic arthritis treated in our institution, and to compare them with other series published in the literature. We conducted a retrospective study of pneumococcal SA identified among all cases of SA diagnosed in a teaching hospital of one thousand beds between 2004 and 2009. Diagnosis was based on culture of joint liquid or by the presence of pneumococcal bacteraemia and purulent (more than 50 000/mm(3) white blood cells with more than 90% neutrophils) joint fluid aspiration. Among 266 cases of SA, nine patients (3·3%) were diagnosed as having pneumococcal SA. The median age was 75 years. The main affected joint was the knee (7/9). No patient had more than one joint involved. Four patients suffered from concomitant pneumonia. Joint culture and blood cultures were positive in 7/9 and 5/9, respectively. Median (range) length of stay was 18 days (3-47 days). One patient with associated pneumococcal bacteraemia died 19 days after admission. Seven patients recovered completely. Streptococcus pneumoniae is now being increasingly recognized as a common agent of SA. This organism is frequently associated with pneumococcal pneumonia or bacteraemia, particularly in patients with advanced age and comorbidities. Direct inoculation of joint fluid into blood culture medium BACTEC system increases the probability of microbiological diagnosis. The prognosis is usually favourable if the disease is promptly recognized and treated (antibiotic therapy combined with joint drainage).

  5. Clofazimine drug susceptibility testing for Mycobacterium tuberculosis: the case of using the right diluent.

    PubMed

    Sng, Li-Hwei; Peh, Justine Woei Ling; Lee Kee, Melody Tai; Ya'akob, Nurhazirah Bte Mohd; Ong, Rick Twee-Hee; Wong, Christopher W; Chee, Cynthia Bin Eng; Wang, Yee Tang

    2018-06-08

    Accurate and reliable drug susceptibility testing (DST) is essential for the effective treatment and control of tuberculosis. With the increase in drug-resistant organisms, newer and less conventional antimicrobial agents are used for treatment. Recently, we found an unprecedented rise in the number of clofazimine-resistant Mycobacterium tuberculosis isolates in our laboratory. An investigation found that this phenomenon was due to a change in the method of drug preparation. We performed studies to assess the impact of water and dimethyl sulfoxide (DMSO) as a final diluent for clofazimine drug testing. Based on our findings, the use of DMSO as a solvent for M. tuberculosis DST was optimised using the BACTEC MGIT 960 platform. Copyright © 2018 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  6. A whole blood bactericidal assay for tuberculosis.

    PubMed

    Wallis, R S; Palaci, M; Vinhas, S; Hise, A G; Ribeiro, F C; Landen, K; Cheon, S H; Song, H Y; Phillips, M; Dietze, R; Ellner, J J

    2001-04-15

    The bactericidal activity of orally administered antituberculosis (anti-TB) drugs was determined in a whole blood culture model of intracellular infection in which microbial killing reflects the combined effects of drug and immune mechanisms. Rifampin (Rif) was the most active compound studied and reduced the number of viable bacilli by >4 logs. Isoniazid (INH), 2 quinolones, and pyrazinamide (PZA) showed intermediate levels of activity. Ethambutol exerted only a bacteristatic effect; amoxicillin/clavulanate was inactive. The combination of INH-Rif-PZA showed strong activity against 11 drug-sensitive isolates (mean, -3.8 log) but no activity against 12 multidrug-resistant (MDR) strains. The combination of levofloxacin-PZA-ethambutol had intermediate bactericidal activity against MDR isolates (mean, -1.2 log) but failed to equal that of INH-Rif-PZA against sensitive isolates (P<.001). The whole blood BACTEC method (Becton Dickinson) may be useful for the early clinical evaluation of new anti-TB drugs and in the management of individual patients.

  7. The Colour Test for drug susceptibility testing of Mycobacterium tuberculosis strains.

    PubMed

    Toit, K; Mitchell, S; Balabanova, Y; Evans, C A; Kummik, T; Nikolayevskyy, V; Drobniewski, F

    2012-08-01

    Tartu, Estonia. To assess the performance and feasibility of the introduction of the thin-layer agar MDR/XDR-TB Colour Test (Colour Test) as a non-commercial method of drug susceptibility testing (DST). The Colour Test combines the thin-layer agar technique with a simple colour-coded quadrant format, selective medium to reduce contamination and colorimetric indication of bacterial growth to simplify interpretation. DST patterns for isoniazid (INH), rifampicin (RMP) and ciprofloxacin (CFX) were determined using the Colour Test for 201 archived Mycobacterium tuberculosis isolates. Susceptibilities were compared to blinded DST results obtained routinely using the BACTEC™ Mycobacteria Growth Indicator Tube™ (MGIT) 960 to assess performance characteristics. In all, 98% of the isolates produced interpretable results. The average time to positivity was 13 days, and all results were interpretable. The Colour Test detected drug resistance with 98% sensitivity for INH, RMP and CFX and 99% for multidrug-resistant tuberculosis. Specificities were respectively 100% (95%CI 82-100), 88% (95%CI 69-97) and 91% (95%CI 83-96) and 90% (95%CI 74-98). Agreement between the Colour Test and BACTEC MGIT 960 were respectively 98%, 96%, 94% and 97%. The Colour Test could be an economical, accurate and simple technique for testing tuberculosis strains for drug resistance. As it requires little specialist equipment, it may be particularly useful in resource-constrained settings with growing drug resistance rates.

  8. Impact of the Mycobaterium africanum West Africa 2 Lineage on TB Diagnostics in West Africa: Decreased Sensitivity of Rapid Identification Tests in The Gambia.

    PubMed

    Ofori-Anyinam, Boatema; Kanuteh, Fatoumatta; Agbla, Schadrac C; Adetifa, Ifedayo; Okoi, Catherine; Dolganov, Gregory; Schoolnik, Gary; Secka, Ousman; Antonio, Martin; de Jong, Bouke C; Gehre, Florian

    2016-07-01

    MPT64 rapid speciation tests are increasingly being used in diagnosis of tuberculosis (TB). Mycobacterium africanum West Africa 2 (Maf 2) remains an important cause of TB in West Africa and causes one third of disease in The Gambia. Since the introduction of MPT64 antigen tests, a higher than expected rate of suspected non-tuberculous mycobacteria (NTM) was seen among AFB smear positive TB suspects, which led us to prospectively assess sensitivity of the MPT64 antigen test in our setting. We compared the abundance of mRNA encoded by the mpt64 gene in sputa of patients with untreated pulmonary TB caused by Maf 2 and Mycobacterium tuberculosis (Mtb). Subsequently, prospectively collected sputum samples from presumptive TB patients were inoculated in the BACTEC MGIT 960 System. One hundred and seventy-three acid fast bacilli (AFB)-positive and blood agar negative MGIT cultures were included in the study. Cultures were tested on the day of MGIT positivity with the BD MGIT TBc Identification Test. A random set of positives and all negatives were additionally tested with the SD Bioline Ag MPT64 Rapid. MPT64 negative cultures were further incubated at 37°C and retested until positive. Bacteria were spoligotyped and assigned to different lineages. Maf 2 isolates were 2.52-fold less likely to produce a positive test result and sensitivity ranged from 78.4% to 84.3% at the beginning and end of the recommended 10 day testing window, respectively. There was no significant difference between the tests. We further showed that the decreased rapid test sensitivity was attributable to variations in mycobacterial growth behavior and the smear grades of the patient. In areas where Maf 2 is endemic MPT64 tests should be cautiously used and MPT64 negative results confirmed by a second technique, such as nucleic acid amplification tests, to avoid their misclassification as NTMs.

  9. Prevalence and molecular characterization of pyrazinamide resistance among multidrug-resistant Mycobacterium tuberculosis isolates from Southern China.

    PubMed

    Pang, Yu; Zhu, Damian; Zheng, Huiwen; Shen, Jing; Hu, Yan; Liu, Jie; Zhao, Yanlin

    2017-11-06

    Pyrazinamide (PZA) plays a unique role in the treatment for multidrug-resistant tuberculosis (MDR-TB) in both first- and second-line regimens. The aim of this study was to investigate the prevalence and molecular characterization of PZA resistance among MDR-TB isolates collected in Chongqing municipality. A total of 133 MDR-TB isolates were collected from the smear-positive tuberculosis patients who were registered at local TB dispensaries of Chongqing. PZA susceptibility testing was determined with a Bactec MGIT 960 system. In addition, the genes conferring for PZA resistance were screened by DNA sequencing. Of these 133 MDR-TB isolates, 83 (62.4%) were determined as PZA-resistant by MGIT 960. In addition, streptomycin- (83.1% vs. 56.0%, P < 0.01), ofloxacin- (51.8% vs. 18.0%, P < 0.01), kanamycin- (22.9% vs. 2.0%, P < 0.01), amikacin- (18.1% vs. 2.0%, P = 0.01), capromycin-resistance (12.0% vs. 2.0%, P = 0.05), were more frequently observed among PZA-resistant isolates compared with PZA-susceptible isolates. Sequence analysis revealed that 73 out of 83 (88.0%) MDR strains harbored a mutation located in the pncA gene, including 55 (75.3%, 55/73) of single nucleotide substitutions and 18 (24.7%, 18/73) of frameshift mutation, while no genetic mutation associated with PZA resistance was found in the rpsA gene. The pncA expression of strains harboring substitution from A to G at position -11 in the promoter region of pncA was significantly lower than that of H37Rv (P < 0.01). In conclusion, our data have demonstrated that the analysis of the pncA gene rather than rpsA gene provides rapid and accurate information regarding PZA susceptibility for MDR-TB isolates in Chongqing. In addition, loss of pncA expression caused by promoter mutation confers PZA resistance in MDR-TB isolates.

  10. [Evaluation of mycobacterial microscopy and culture results of Sureyyapasa Chest Diseases and Chest Surgery Training and Research Hospital: A 3-year analysis].

    PubMed

    Akduman Alaşehir, Elçin; Balıkçı, Ahmet; Partal, Mualla; Çatmabacak, Gülay; Yaman, Görkem

    2016-09-01

    Effective diagnosis of tuberculosis is of great importance for transmission control and treatment success. The purpose of this study is to evaluate microscopic examination results of Ehrlich-Ziehl Neelsen (EZN) and Auramine-Rhodamine staining methods and automated BACTEC MGIT 960™ system and Löwenstein-Jensen (L-J) culture results of various clinical samples in the light of recent data from the world and Turkey. Specimens that were sent from various clinics to Sureyyapasa Chest Diseases and Chest Surgery Training and Research Hospital Microbiology Laboratory from January 2012 to December 2015 were evaluated retrospectively. From a total of 62456 samples; 60923 (97.5%) were pulmonary and 1533 (2.5%) were non-pulmonary samples, especially pleura. 2853 (4.6%) Acid-resistant bacilli (ARB) positivity was detected and mycobacterial culture positivity was in total 12.2%. 7076 (93%) and 535 (7%) mycobacteria other than tuberculosis (MOTT) strains were isolated. In 356 specimens the cultures were negative in despite the positive ARB results. Considering mycobacterial culture as the gold standard; the sensitivity, specificity, positive and negative predictive values of ARB microscopy were 32.8%, 99.4%, 87.5% and 91.4%, respectively. The contamination rates in total were within acceptable limits being 2.7% for L-J and 3.8% for MGIT. Analysis of our data indicated that the sensitivity of microscopy is low and it should be evaluated together with the mycobacterial culture to rule out tuberculosis infection. With the use of fluorescent staining and also L-J and MGIT broth together for routine culture since 2013; ARB false negativity rate was observed to fall to 51.7% from 74.1% compared to the years. The follow-up of data such as the sensitivity of microscopy, culture positivity, false-positivity and false-negativity rates and contamination values is of great importance in terms of assessing compliance with laboratory quality standards and contributing to the surveillance studies.

  11. Mycobacterium Avium subsp. Paratuberculosis Isolates Induce In Vitro Granuloma Formation and Show Successful Survival Phenotype, Common Anti-Inflammatory and Antiapoptotic Responses within Ovine Macrophages Regardless of Genotype or Host of Origin

    PubMed Central

    Abendaño, Naiara; Tyukalova, Lyudmila; Barandika, Jesse F.; Balseiro, Ana; Sevilla, Iker A.; Garrido, Joseba M.; Juste, Ramon A.; Alonso-Hearn, Marta

    2014-01-01

    The analysis of the early macrophage responses, including bacterial growth within macrophages, represents a powerful tool to characterize the virulence of clinical isolates of Mycobcaterium avium susbp. paratuberculosis (Map). The present study represents the first assessment of the intracellular behaviour in ovine monocyte-derived macrophages (MDMs) of Map isolates representing distinct genotypes (C, S and B), and isolated from cattle, sheep, goat, fallow deer, deer, and wild boar. Intracellular growth and survival of the selected isolates in ovine MDMs was assessed by quantification of CFUs inside of the host cells at 2 h p.i. (day 0) and 7 d p. i. using an automatic liquid culture system (Bactec MGIT 960). Variations in bacterial counts over 7 days from the baseline were small, in a range between 1.63 to 1.05-fold. After 7 d of infection, variations in the estimated log10 CFUs between all the tested isolates were not statistically significant. In addition, ovine MDMs exhibited enhanced anti-inflammatory, antiapoptotic and antidestructive responses when infected with two ovine isolates of distinct genotype (C and S) or with two C-type isolates from distinct hosts (cattle and sheep); which correlated with the successful survival of these isolates within ovine MDMs. A second objective was to study, based on an in vitro granuloma model, latter stages of the infection by investigating the capacity of two Map isolates from cattle and sheep to trigger formation of microgranulomas. Upon 10 d p.i., both Map isolates were able to induce the formation of granulomas comparable to the granulomas observed in clinical specimens with respect to the cellular components involved. In summary, our results demonstrated that Map isolates from cattle, sheep, goats, deer, fallow-deer and wild boar were able not only to initiate but also to establish a successful infection in ovine macrophages regardless of genotype. PMID:25111300

  12. Rapid, Standardized Method for Determination of Mycobacterium tuberculosis Drug Susceptibility by Use of Mycolic Acid Analysis▿

    PubMed Central

    Parrish, Nicole; Osterhout, Gerard; Dionne, Kim; Sweeney, Amy; Kwiatkowski, Nicole; Carroll, Karen; Jost, Kenneth C.; Dick, James

    2007-01-01

    Multidrug-resistant (MDR) Mycobacterium tuberculosis and extrensively drug-resistant (XDR) M. tuberculosis are emerging public health threats whose threats are compounded by the fact that current techniques for testing the susceptibility of M. tuberculosis require several days to weeks to complete. We investigated the use of high-performance liquid chromatography (HPLC)-based quantitation of mycolic acids as a means of rapidly determining drug resistance and susceptibility in M. tuberculosis. Standard susceptibility testing and determination of the MICs of drug-susceptible (n = 26) and drug-resistant M. tuberculosis strains, including MDR M. tuberculosis strains (n = 34), were performed by using the Bactec radiometric growth system as the reference method. The HPLC-based susceptibilities of the current first-line drugs, isoniazid (INH), rifampin (RIF), ethambutol (EMB), and pyrazinamide (PZA), were determined. The vials were incubated for 72 h, and aliquots were removed for HPLC analysis by using the Sherlock mycobacterial identification system. HPLC quantitation of total mycolic acid peaks (TMAPs) was performed with treated and untreated cultures. At 72 h, the levels of agreement of the HPLC method with the reference method were 99.5% for INH, EMB, and PZA and 98.7% for RIF. The inter- and intra-assay reproducibilities varied by drug, with an average precision of 13.4%. In summary, quantitation of TMAPs is a rapid, sensitive, and accurate method for antibiotic susceptibility testing of all first-line drugs currently used against M. tuberculosis and offers the potential of providing susceptibility testing results within hours, rather than days or weeks, for clinical M. tuberculosis isolates. PMID:17913928

  13. Salmonella Bacteremia Among Children in Central and Northwest Nigeria, 2008–2015

    PubMed Central

    Obaro, Stephen K.; Hassan-Hanga, Fatimah; Olateju, Eyinade K.; Umoru, Dominic; Lawson, Lovett; Olanipekun, Grace; Ibrahim, Sadeeq; Munir, Huda; Ihesiolor, Gabriel; Maduekwe, Augustine; Ohiaeri, Chinatu; Adetola, Anthony; Shetima, Denis; Jibir, Binta W.; Nakaura, Hafsat; Kocmich, Nicholas; Ajose, Therasa; Idiong, David; Masokano, Kabir; Ifabiyi, Adeyemi; Ihebuzor, Nnenna; Chen, Baojiang; Meza, Jane; Akindele, Adebayo; Rezac-Elgohary, Amy; Olaosebikan, Rasaq; Suwaid, Salman; Gambo, Mahmoud; Alter, Roxanne; Davies, Herbert D.; Fey, Paul D.

    2015-01-01

    Background. Etiologic agents of childhood bacteremia remain poorly defined in Nigeria. The absence of such data promotes indiscriminate use of antibiotics and delays implementation of appropriate preventive strategies. Methods. We established diagnostic laboratories for bacteremia surveillance at regional sites in central and northwest Nigeria. Acutely ill children aged <5 years with clinically suspected bacteremia were evaluated at rural and urban clinical facilities in the Federal Capital Territory, central region and in Kano, northwest Nigeria. Blood was cultured using the automated Bactec incubator system. Results. Between September 2008 and April 2015, we screened 10 133 children. Clinically significant bacteremia was detected in 609 of 4051 (15%) in the northwest and 457 of 6082 (7.5%) in the central region. Across both regions, Salmonella species account for 24%–59.8% of bacteremias and are the commonest cause of childhood bacteremia, with a predominance of Salmonella enterica serovar Typhi. The prevalence of resistance to ampicillin, chloramphenicol, and cotrimoxazole was 38.11%, with regional differences in susceptibility to different antibiotics but high prevalence of resistance to readily available oral antibiotics. Conclusions. Salmonella Typhi is the leading cause of childhood bacteremia in central Nigeria. Expanded surveillance is planned to define the dynamics of transmission. The high prevalence of multidrug-resistant strains calls for improvement in environmental sanitation in the long term and vaccination in the short term. PMID:26449948

  14. In vitro effects of citrus oils against Mycobacterium tuberculosis and non-tuberculous Mycobacteria of clinical importance.

    PubMed

    Crandall, Philip G; Ricke, Steven C; O'Bryan, Corliss A; Parrish, Nicole M

    2012-01-01

    We evaluated the in vitro activity of citrus oils against Mycobacterium tuberculosis and other non-tuberculous Mycobacterium species. Citrus essential oils were tested against a variety of Mycobacterium species and strains using the BACTEC radiometric growth system. Cold pressed terpeneless Valencia oil (CPT) was further tested using the Wayne model of in vitro latency. Exposure of M. tuberculosis and M. bovis BCG to 0.025 % cold pressed terpeneless Valencia orange oil (CPT) resulted in a 3-log decrease in viable counts versus corresponding controls. Inhibition of various clinical isolates of the M. avium complex and M. abscessus ranged from 2.5 to 5.2-logs. Some species/strains were completely inhibited in the presence of CPT including one isolate each of the following: the M. avium complex, M. chelonae and M. avium subsp. paratuberculosis. CPT also inhibited the growth of BCG more than 99 % in an in vitro model of latency which mimics anaerobic dormancy thought to occur in vivo. The activity of CPT against drug-resistant strains of the M. avium complex and M. abscessus suggest that the mechanism of action for CPT is different than that of currently available drugs. Inhibition of latently adapted bacilli offers promise for treatment of latent infections of MTB. These results suggest that the antimycobacterial properties of CPT warrant further study to elucidate the specific mechanism of action and clarify the spectrum of activity.

  15. Rapid identification of bacteria from positive blood culture bottles by use of matrix-assisted laser desorption-ionization time of flight mass spectrometry fingerprinting.

    PubMed

    Christner, Martin; Rohde, Holger; Wolters, Manuel; Sobottka, Ingo; Wegscheider, Karl; Aepfelbacher, Martin

    2010-05-01

    Early and adequate antimicrobial therapy has been shown to improve the clinical outcome in bloodstream infections (BSI). To provide rapid pathogen identification for targeted treatment, we applied matrix-assisted laser desorption-ionization time of flight (MALDI-TOF) mass spectrometry fingerprinting to bacteria directly recovered from blood culture bottles. A total of 304 aerobic and anaerobic blood cultures, reported positive by a Bactec 9240 system, were subjected in parallel to differential centrifugation with subsequent mass spectrometry fingerprinting and reference identification using established microbiological methods. A representative spectrum of bloodstream pathogens was recovered from 277 samples that grew a single bacterial isolate. Species identification by direct mass spectrometry fingerprinting matched reference identification in 95% of these samples and worked equally well for aerobic and anaerobic culture bottles. Application of commonly used score cutoffs to classify the fingerprinting results led to an identification rate of 87%. Mismatching mostly resulted from insufficient bacterial numbers and preferentially occurred with Gram-positive samples. The respective spectra showed low concordance to database references and were effectively rejected by score thresholds. Spiking experiments and examination of the respective study samples even suggested applicability of the method to mixed cultures. With turnaround times around 100 min, the approach allowed for reliable pathogen identification at the day of blood culture positivity, providing treatment-relevant information within the critical phase of septic illness.

  16. Evaluation of a Rapid Fecal PCR Test for Detection of Mycobacterium avium subsp. paratuberculosis in Dairy Cattle▿

    PubMed Central

    Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.

    2006-01-01

    A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884

  17. Amplification of ST50 gene using dry-reagent-based polymerase chain reaction for the detection of Salmonella typhi.

    PubMed

    Aziah, Ismail; Ravichandran, Manickam; Ismail, Asma

    2007-12-01

    Conventional polymerase chain reaction (PCR) testing requires many pipetting steps and has to be transported and stored in cold chain. To overcome these limitations, we designed a ready-to-use PCR test for Salmonella typhi using PCR reagents, primers against the ST50 gene of S. typhi, a built-in internal amplification control (IAC), and gel loading dye mixed and freeze-dried in a single tube. The 2-step dry-reagent-based assay was used to amplify a 1238-bp target gene and an 810-bp IAC gene from 73 BACTEC blood culture broths (33 true positives for S. typhi and 40 true negatives for non-S. typhi). The sensitivity, specificity, positive predictive value, and negative predictive value of the PCR assay were 87.9%, 100%, 100%, and 90.9%, respectively. We suggest that this rapid 2-step PCR test could be used for the rapid diagnosis of typhoid fever.

  18. In vitro activities of levofloxacin used alone and in combination with first- and second-line antituberculous drugs against Mycobacterium tuberculosis.

    PubMed Central

    Rastogi, N; Goh, K S; Bryskier, A; Devallois, A

    1996-01-01

    By using the radiometric BACTEC 460-TB methodology, the inhibitory and bactericidal activity of the optically active L-isomer of ofloxacin (levofloxacin) was compared with those of the D-isomer and the commercially available mixture containing equal amounts of DL-isomers (ofloxacin) against the Mycobacterium tuberculosis complex (type strain H37Rv, a panel of drug-susceptible and -resistant clinical isolates including multidrug-resistant isolates of M. tuberculosis, as well as M. africanum, M. bovis, and M. bovis BCG). Levofloxacin MICs (range 0.50 to 0.75 microgram/ml) were about 1 dilution lower than those of ofloxacin (MIC range, 0.75 to 1.00 microgram/ml) and 5 to 6 dilutions lower than those of the D-isomer (MIC range, 32 to 60 micrograms/ml). The MICs of levofloxacin, ofloxacin, and D-ofloxacin at which 90% of the strains are inhibited were 0.50, 1.00, and 64 micrograms/ml, respectively. The multidrug-resistant M. tuberculosis strains resistant to first-line drugs were as susceptible to quinolones as the wild-type drug-susceptible isolates. Levofloxacin at 0.5 microgram/ml showed bactericidal activity comparable to the activities of 1.0 microgram of ofloxacin per ml and 64 micrograms of D-ofloxacin per ml, with MBCs within the range of 0.5 to 2.0 micrograms/ml, compared with MBCs of 0.75 to 4.0 micrograms of ofloxacin per ml for M. tuberculosis, M. africanum, M. bovis BCG. Combination testing of sub-MICs of levolofoxacin with other first-line (isoniazid, rifampin, and ethambutol) and second-line (amikacin and clofazimine) antituberculous drugs was evaluated with various two-, three-, and four-drug combinations; enhanced drug activity was observed in 8 of 25, 12 of 20, and 8 of 15 tests, respectively, indicating that levofloxacin acts in synergy with other antituberculous drugs. PMID:8807049

  19. Staphylococcus aureus bacteremias following liver transplantation: a clinical analysis of 20 cases.

    PubMed

    Zhou, Jiandang; Huang, Hui; Liu, Shan; Yu, Ping; Wan, Qiquan

    2015-01-01

    To describe the incidence, clinical characteristics, and outcomes of Staphylococcus aureus bacteremia after liver transplantation and investigate the drug resistance of S. aureus to frequently used antibiotics to provide evidence for clinical prevention and therapy. In a double-center retrospective study, blood cultures positive for S. aureus were obtained from January 1, 2001 to December 31, 2014. The BACTEC 9120 blood culture system and the Vitek-2 system were used to process blood samples and identify species, respectively. We also collected these patients' data to confirm clinical and laboratory characteristics. Twenty of 275 (7.3%) liver recipients developed S. aureus bacteremia during the study period. The median time to the onset of S. aureus bacteremias was 6 days after liver transplantation and all episodes of bacteremias were early onset. The lung was the most common source of primary infection, followed by the intra-abdominal/biliary tract. A total of nine (45%) liver recipients died due to S. aureus bacteremias. Of these 20 S. aureus cases, 80% were methicillin-resistant. S. aureus was highly resistant to erythromycin and penicillin (resistance rate >90%). No S. aureus resistant to glycopeptides and oxazolidone antibiotics was observed. There were seven (35%) liver recipients with an inappropriate antibiotic therapy. Between the periods of 2001-2007 and 2008-2014, the distribution of methicillin-resistant S. aureus was not significantly different (P=1.000). Pneumonia as a predominant primary source, a high body temperature, abnormal blood pressure, and decreased platelets, which occurred in the early period after liver transplantation, as well as high morbidity and mortality, were the main characteristics of S. aureus bacteremias. S. aureus led to severe bacteremias in liver recipients, with high morbidity and mortality, and the majority of them comprised methicillin-resistant S. aureus.

  20. Evaluation of PMS-PCR technology for detection of Mycobacterium avium subsp. paratuberculosis directly from bovine fecal specimens.

    PubMed

    Salgado, M; Steuer, P; Troncoso, E; Collins, M T

    2013-12-27

    Mycobacterium avium subsp. paratuberculosis (MAP) causes paratuberculosis, or Johne's disease, in animals. Diagnosis of MAP infection is challenging because of the pathogen's fastidious in vitro growth requirements and low-level intermittent shedding in feces during the preclinical phase of the infection. Detection of these "low-shedders" is important for effective control of paratuberculosis as these animals serve as sources of infection for susceptible calves. Magnetic separation technology, used in combination with culture or molecular methods for the isolation and detection of pathogenic bacteria, enhances the analytical sensitivity and specificity of detection methods. The aim of the present study was to evaluate peptide-mediated magnetic separation (PMS) capture technology coupled with IS900 PCR using the Roche real-time PCR system (PMS-PCR), in comparison with fecal culture using BACTEC-MGIT 960 system, for detection of MAP in bovine fecal samples. Among the 351 fecal samples 74.9% (263/351) were PMS-PCR positive while only 12.3% (43/351) were MGIT culture-positive (p=0.0001). All 43 MGIT culture-positive samples were also positive by PMS-PCR. Mean PMS-PCR crossing-point (Cp) values for the 13 fecal samples with the highest number of MAP, based on time to detection, (26.3) were significantly lower than for the 17 fecal samples with <100 MAP per 2g feces (30.06) (p<0.05). PMS-PCR technology provided results in a shorter time and yielded a higher number of positive results than MGIT culture. Earlier and faster detection of animals shedding MAP by PMS-PCR should significantly strengthen control efforts for MAP-infected cattle herds by helping to limit infection transmission at earlier stages of the infection. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Does neutralization of gastric aspirates from children with suspected intrathoracic tuberculosis affect mycobacterial yields on MGIT culture?

    PubMed

    Parashar, Deepak; Kabra, Sushil K; Lodha, Rakesh; Singh, Varinder; Mukherjee, Aparna; Arya, Tina; Grewal, Harleen M S; Singh, Sarman

    2013-06-01

    The microbiological confirmation of pulmonary tuberculosis in children relies on cultures of gastric aspirate (GA) specimens. Conventionally, GAs are neutralized to improve culture yields of mycobacteria. However, there are limited data to support this practice. To study the utility of neutralization of GAs with sodium bicarbonate in children with intrathoracic tuberculosis, a total of 116 children of either sex, aged 6 months to 14 years (median age, 120 months; interquartile range [IQR], 7 to 192 months), underwent gastric aspiration on 2 consecutive days. Gastric aspirates were divided into two aliquots, and only one aliquot was neutralized with 1% sodium bicarbonate. Both aliquots were processed for smear and culture examinations. Out of the 232 gastric aspirates, 12 (5.17%) were acid-fast bacilli (AFB) smear positive. There were no differences in smear positivity rates from samples with or without neutralization. The yield of Mycobacterium tuberculosis on a Bactec MGIT 960 culture system was significantly lower in the neutralized samples (16.3% [38/232]) than in the nonneutralized samples (21.5% [50/232]) (P = 0.023). There was no significant difference between the neutralized and the nonneutralized samples in time to detection using the MGIT 960 system (average, 24.6 days; IQR, 12 to 37 days) (P = 0.9). The contamination rates were significantly higher in the neutralized samples than in the nonneutralized samples (17.2% [40/232] versus 3.9% [9/232]) (P = 0.001). The agreement for positive mycobacterial culture between the two approaches was 66.5% (P = 0.001). Hence, we recommend that gastric aspirate samples not be neutralized with sodium bicarbonate prior to culture for M. tuberculosis.

  2. Effect of pasteurization on survival of Mycobacterium paratuberculosis in milk.

    PubMed

    Gao, A; Mutharia, L; Chen, S; Rahn, K; Odumeru, J

    2002-12-01

    Mycobacterium paratuberculosis (Mptb) is the causative agent of Johne's disease of ruminant animals including cattle, goats, and sheep. It has been suggested that this organism is associated with Crohn's disease in humans, and milk is a potential source of human exposure to this organism. A total of 18, including 7 regular batch and 11 high temperature short time (HTST) pasteurization experiments, were conducted in this study. Raw milk or ultra-high temperature pasteurized milk samples were spiked at levels of 10(3), 10(5), and 10(7) cfu of Mptb/ml. Escherichia coli and Mycobacterium bovis BCG strains at 10(7) cfu/ml were used as controls. Pasteurization experiments were conducted using time and temperature standards specified in the Canadian National Dairy Code: regular batch pasteurization method: 63 degrees C for 30 min, and HTST method: 72 degrees C for 15 s. The death curve of this organism was assessed at 63 degrees C. No survivors were detected after 15 min. Each spiked sample was cultured in Middlebrook 7H9 culture broth and Middlebrook 7H11 agar slants. Samples selected from 15 experiments were also subjected to BACTEC culture procedure. Survival of Mptb was confirmed by IS900-based PCR of colonies recovered on slants. No survivors were detected from any of the slants or broths corresponding to the seven regular batch pasteurization trials. Mptb survivors were detected in two of the 11 HTST experiments. One was by both slant and broth culture for the sample spiked to 10(7) cfu/ml of Mptb, while the other was detected by BACTEC for the sample spiked to 10(5) cfu/ml. These results indicate that Mptb may survive HTST pasteurization when present at > or = 10(5) cfu/ml in milk. A total of 710 retail milk samples collected from retail store and dairy plants in southwest Ontario were tested by nested IS900 PCR for the presence of Mptb. Fifteen percent of these samples (n = 110) were positive. However, no survivors were isolated from the broth and agar cultures of 44 PCR positive and 200 PCR negative retail milk samples. The lack of recovery of live Mptb from the retail milk samples tested may be due to either the absence of live Mptb in the retail milk samples tested or the presence of low number of viable Mptb which were undetected by the culture method used in this study.

  3. Rapid diagnosis of pulmonary tuberculosis and detection of drug resistance by combined simultaneous amplification testing and reverse dot blot.

    PubMed

    Chen, Yiwen; Zhang, Lahong; Hong, Liquan; Luo, Xian; Chen, Juping; Tang, Leiming; Chen, Jiahuan; Liu, Xia; Chen, Zhaojun

    2018-06-01

    Making a correct and rapid diagnosis is essential for managing pulmonary tuberculosis (PTB), particularly multidrug-resistant tuberculosis. We aimed to evaluate the efficacy of the combination of simultaneous amplification testing (SAT) and reverse dot blot (RDB) for the rapid detection of Mycobacterium tuberculosis (MTB) and drug-resistant mutants in respiratory samples. 225 suspected PTB and 32 non-TB pulmonary disease samples were collected. All sputum samples were sent for acid-fast bacilli smear, SAT, culture and drug susceptibility testing (DST) by the BACTEC TM MGIT TM 960 system. 53 PTB samples were tested by both RDB and DNA sequencing to identify drug resistance genes and mutated sites. The SAT positive rate (64.9%) was higher than the culture positive rate (55.1%), with a coincidence rate of 83.7%. The sensitivity and specificity of SAT for diagnosing PTB were 66.7% and 100%, respectively, while those for culture were 53.9% and 84.2%, respectively. RDB has high sensitivity and specificity in identifying drug resistance genes and mutated sites. The results of RDB correlated well with those of DST and DNA sequencing, with coincidence rates of 92.5% and 98.1%, respectively. The combination of SAT and RDB is promising for rapidly detecting PTB and monitoring drug resistance in clinical laboratories. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Novel, improved sample preparation for rapid, direct identification from positive blood cultures using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry.

    PubMed

    Schubert, Sören; Weinert, Kirsten; Wagner, Chris; Gunzl, Beatrix; Wieser, Andreas; Maier, Thomas; Kostrzewa, Markus

    2011-11-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is widely used for rapid and reliable identification of bacteria and yeast grown on agar plates. Moreover, MALDI-TOF MS also holds promise for bacterial identification from blood culture (BC) broths in hospital laboratories. The most important technical step for the identification of bacteria from positive BCs by MALDI-TOF MS is sample preparation to remove blood cells and host proteins. We present a method for novel, rapid sample preparation using differential lysis of blood cells. We demonstrate the efficacy and ease of use of this sample preparation and subsequent MALDI-TOF MS identification, applying it to a total of 500 aerobic and anaerobic BCs reported to be positive by a Bactec 9240 system. In 86.5% of all BCs, the microorganism species were correctly identified. Moreover, in 18/27 mixed cultures at least one isolate was correctly identified. A novel method that adjusts the score value for MALDI-TOF MS results is proposed, further improving the proportion of correctly identified samples. The results of the present study show that the MALDI-TOF MS-based method allows rapid (<20 minutes) bacterial identification directly from positive BCs and with high accuracy. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  5. Assessment of the sensitivity and specificity of Xpert MTB/RIF assay as an early sputum biomarker of response to tuberculosis treatment.

    PubMed

    Friedrich, Sven O; Rachow, Andrea; Saathoff, Elmar; Singh, Kasha; Mangu, Chacha D; Dawson, Rodney; Phillips, Patrick Pj; Venter, Amour; Bateson, Anna; Boehme, Catharina C; Heinrich, Norbert; Hunt, Robert D; Boeree, Martin J; Zumla, Alimuddin; McHugh, Timothy D; Gillespie, Stephen H; Diacon, Andreas H; Hoelscher, Michael

    2013-08-01

    An accurate biomarker is urgently needed to monitor the response to treatment in patients with pulmonary tuberculosis. The Xpert MTB/RIF assay is a commercially available real-time PCR that can be used to detect Mycobacterium-tuberculosis-specific DNA sequences in sputum samples. We therefore evaluated this assay with serial sputum samples obtained over 26 weeks from patients undergoing treatment for tuberculosis. We analysed sputum samples from 221 patients with smear-positive tuberculosis enrolled at two sites (Cape Town, South Africa, and Mbeya, Tanzania) of a multicentre randomised clinical trial REMoxTB of antituberculosis treatment on a weekly basis (weeks 0 to 8), then at weeks 12, 17, 22, and 26 after treatment initiation. The Xpert MTB/RIF results over time were compared with the results of standard smear microscopy and culture methods. We obtained and analysed 2741 sputum samples from 221 patients. The reduction in positivity rates with Xpert MTB/RIF were slower than those with the standard methods. At week 8, positive results were obtained for 62 (29%) of 212 sputum samples with smear microscopy, 46 (26%) of 175 with solid culture (Löwenstein-Jensen medium), 77 (42%) of 183 with liquid culture (Bactec MGIT960 system), and 174 (84%) of 207 with Xpert MTB/RIF; at 26 weeks, positive results were obtained for ten (5%) of 199, four (3%) of 157, seven (4%) of 169, and 22 (27%) of 83 sputum samples, respectively. The reduction in detection of quantitative M tuberculosis DNA with Xpert MTB/RIF correlated with smear grades (ρ=-0·74; p<0·0001), solid culture grades (ρ=-0·73; p<0·0001), and time to liquid culture positivity (ρ=0·73; p<0·0001). Compared with the combined binary smear and culture results as a reference standard, the Xpert MTB/RIF assay had high sensitivity (97·0%, 95% CI 95·8-97·9), but poor specificity (48·6%, 45·0-52·2). The poor specificity precludes the use of the Xpert MTB/RIF assay as a biomarker for monitoring tuberculosis treatment, and should not replace standard smear microscopy and culture. Global Alliance for TB Drug Development, Bill & Melinda Gates Foundation, UK Medical Research Council, German Ministry of Science and Technology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. RHB-104 triple antibiotics combination in culture is bactericidal and should be effective for treatment of Crohn's disease associated with Mycobacterium paratuberculosis.

    PubMed

    Alcedo, Karel P; Thanigachalam, Saisathya; Naser, Saleh A

    2016-01-01

    Mycobacterium avium subspecies paratuberculosis (MAP) has been implicated as an etiological agent of Crohn's disease (CD), a debilitating chronic inflammatory bowel disease. Clarithromycin (CLA), clofazimine (CLO), rifabutin (RIF) and other antibiotics have been used individually or in combinations with other drugs to treat mycobacterial diseases including CD. The treatment has varied by regimen, dosage, and duration, resulting in conflicting outcomes and additional suffering to the patients. RHB-104, a drug formula with active ingredients composed of (63.3 %) CLA, (6.7 %) CLO, and (30 %) RIF, has been recently subjected to investigation in an FDA approved Phase III clinical trial to treat patients with moderate to severe CD. In this study, we determined the efficacy of RHB-104 active ingredients against MAP strains isolated from the blood, tissue, and milk of CD patients. Based on fluorescence quenching technology using the Bactec MGIT Para-TB medium, we determined the minimum inhibitory concentration (MIC) of CLA, CLO, RIF individually and in dual and triple combinations against 16 MAP clinical strains and 19 other mycobacteria. The MIC of all drugs against 35 different mycobacteria ranged between 0.25-20 μg/mL. However, the MIC of RHB-104 active ingredients regimen was the lowest at 0.25-10 μg/mL compared to the MIC of the other drugs at 0.5-20 μg/mL. The components of RHB-104 active ingredients at their individual concentrations or in dual combinations were not effective against all microorganisms compared to the triple combinations at MIC level. The MIC of CLA-CLO, CLA-RIF, and CLO-RIF regimens ranged between 0.5-1.25 μg/mL compared to 0.25 μg/mL of bactericidal effect of the triple combination. The data clearly demonstrated that lower concentrations of the triple combination of RHB-104 active ingredients provided synergistic anti-MAP growth activity compared to individual or dual combinations of the drugs. Consequently, this is favorable and should lead to tolerable dosage that is desirable for long-term treatment of CD and Mycobacterium avium complex disease.

  7. Evaluation of the GenoType MTBDRsl Version 2.0 Assay for Second-Line Drug Resistance Detection of Mycobacterium tuberculosis Isolates in South Africa

    PubMed Central

    Dreyer, A. W.; Koornhof, H. J.; Omar, S. V.; da Silva, P.; Bhyat, Z.; Ismail, N. A.

    2016-01-01

    ABSTRACT Early detection of resistance to second-line antituberculosis drugs is important for the management of multidrug-resistant tuberculosis (MDR-TB). The GenoType MTBDRsl version 2.0 (VER 2.0) line probe assay has been redesigned for molecular detection of resistance-conferring mutations of fluoroquinolones (FLQ) (gyrA and gyrB genes) and second-line injectable drugs (SLID) (rrs and eis genes). The study evaluated the diagnostic performance of the GenoType MTBDRsl VER 2.0 assay for the detection of second-line drug resistance compared with phenotypic drug susceptibility testing (DST), using the Bactec MGIT 960 system on Mycobacterium tuberculosis complex isolates from South Africa. A total of 268 repository isolates collected between 2012 and 2014, which were rifampin monoresistant or MDR based on DST, were selected. MTBDRsl VER 2.0 testing was performed on these isolates and the results analyzed. The MTBDRsl VER 2.0 sensitivity and specificity indices for culture isolates were the following: FLQ, 100% (95% confidence interval [CI] 95.8 to 100%) and 98.9% (95% CI, 96.1 to 99.9%); SLID, 89.2% (95% CI, 79.1 to 95.6%) and 98.5% (95% CI, 95.7 to 99.7%). The sensitivity and specificity observed for individual SLID were the following: amikacin, 93.8% (95% CI, 79.2 to 99.2%) and 98.5% (95% CI, 95.5 to 99.7%); kanamycin, 89.2% (95% CI, 79.1 to 95.6%) and 98.5% (95% CI, 95.5 to 99.7%); and capreomycin, 86.2% (95% CI, 68.3 to 96.1%) and 95.9% (95% CI, 92.2 to 98.2%). An interoperator reproducibility of 100% and an overall interlaboratory performance of 93% to 96% were found. The overall improvement in sensitivity and specificity with excellent reproducibility makes the GenoType MTBDRsl VER 2.0 a highly suitable tool for rapid screening of clinical isolates for second-line drug resistance for use in high-burden TB/HIV settings. PMID:27974543

  8. Prevalence of paratuberculosis in the dairy goat and dairy sheep industries in Ontario, Canada.

    PubMed

    Bauman, Cathy A; Jones-Bitton, Andria; Menzies, Paula; Toft, Nils; Jansen, Jocelyn; Kelton, David

    2016-02-01

    A cross-sectional study was undertaken (October 2010 to August 2011) to estimate the prevalence of paratuberculosis in the small ruminant dairy industries in Ontario, Canada. Blood and feces were sampled from 580 goats and 397 sheep (lactating and 2 y of age or older) that were randomly selected from 29 randomly selected dairy goat herds and 21 convenience-selected dairy sheep flocks. Fecal samples were analyzed using bacterial culture (BD BACTEC MGIT 960) and polymerase chain reaction (Tetracore); serum samples were tested with the Prionics Parachek enzyme-linked immunosorbent assay (ELISA). Using 3-test latent class Bayesian models, true farm-level prevalence was estimated to be 83.0% [95% probability interval (PI): 62.6% to 98.1%] for dairy goats and 66.8% (95% PI: 41.6% to 91.4%) for dairy sheep. The within-farm true prevalence for dairy goats was 35.2% (95% PI: 23.0% to 49.8%) and for dairy sheep was 48.3% (95% PI: 27.6% to 74.3%). These data indicate that a paratuberculosis control program for small ruminants is needed in Ontario.

  9. Effect of high-temperature, short-time (HTST) pasteurization on milk containing low numbers of Mycobacterium paratuberculosis.

    PubMed

    Grant, I R; Ball, H J; Rowe, M T

    1998-02-01

    The efficacy of high-temperature, short-time (HTST) pasteurization (72 degrees C/15 s) when low numbers (< or = 10(3) cfu ml-1) of Mycobacterium paratuberculosis are present in milk was investigated. Raw cows' milk spiked with Myco. paratuberculosis (10(3) cfu ml-1, 10(2) cfu ml-1, 10 cfu ml-1, and 10 cfu 50 ml-1) was subjected to HTST pasteurization using laboratory pasteurizing units. Ten bovine strains of Myco. paratuberculosis were tested in triplicate. Culture in BACTEC Middlebrook 12B radiometric medium detected acid-fast survivors in 14.8% and 10% of HTST-pasteurized milk samples at the 10(3) and 10(2) cfu ml-1 inoculum levels, respectively, whereas conventional culture on Herrold's egg yolk medium containing mycobactin J detected acid-fast survivors in only 3.7% and 6.7% of the same milk samples. IS900-based PCR confirmed that these acid-fast survivors were Myco. paratuberculosis. No viable Myco. paratuberculosis were isolated from HTST-pasteurized milk initially containing either 10 cfu ml-1 or 10 cfu 50 ml-1.

  10. French multicenter study involving eight test sites for radiometric determination of activities of 10 antimicrobial agents against Mycobacterium avium complex.

    PubMed Central

    Rastogi, N; Bauriaud, R M; Bourgoin, A; Carbonnelle, B; Chippaux, C; Gevaudan, M J; Goh, K S; Moinard, D; Roos, P

    1995-01-01

    The radiometric BACTEC 460-TB methodology has filled an increased need in the screening of a wide range of antimicrobial agents against Mycobacterium avium (MAC) isolates on a patient-to-patient basis. In this context, a multicenter study involving eight test sites across France was performed to determine the MICs of 10 antimicrobial agents for MAC organisms. The aim of the investigation was to compare the in vitro activities of D-cycloserine, ethambutol, ethionamide, rifampin, amikacin, streptomycin, ciprofloxacin, sparfloxacin, clofazimine, and clarithromycin against MAC isolates. All of the test sites received the same clinical isolates of MAC, and the MICs were determined by a common protocol. The overall interlaboratory reproducibility of the MICs within +/- 1 dilution of the modal MICs varied from 79.70 to 100% (mean, 95.2% +/- 2.1%), whereas overall agreement of the MICs among the test sites varied from a mean of 91% +/- 4.1% to a mean of 98 +/- 1.3%. We confirmed that the proposed methodology is easy, accurate, and sufficiently reproducible to be used routinely in a clinical laboratory. Despite variations in the MICs of the same drug among strains, no link between the origin of MAC isolates (from human immunodeficiency virus-positive or -negative patients) and their drug susceptibilities was established. On the basis of the MICs that inhibited 50 and 90% of isolates tested for the drugs used, clarithromycin, clofazimine, ethambutol, and streptomycin were the most uniformly active against MAC; this was followed by amikacin, rifampin, and sparfloxacin. On the other hand, ciprofloxacin, D-cycloserine, and ethionamide showed only marginal in vitro activities. PMID:7793865

  11. Wild-type MIC distributions for aminoglycoside and cyclic polypeptide antibiotics used for treatment of Mycobacterium tuberculosis infections.

    PubMed

    Juréen, P; Angeby, K; Sturegård, E; Chryssanthou, E; Giske, C G; Werngren, J; Nordvall, M; Johansson, A; Kahlmeter, G; Hoffner, S; Schön, T

    2010-05-01

    The aminoglycosides and cyclic polypeptides are essential drugs in the treatment of multidrug-resistant tuberculosis, underscoring the need for accurate and reproducible drug susceptibility testing (DST). The epidemiological cutoff value (ECOFF) separating wild-type susceptible strains from non-wild-type strains is an important but rarely used tool for indicating susceptibility breakpoints against Mycobacterium tuberculosis. In this study, we established wild-type MIC distributions on Middlebrook 7H10 medium for amikacin, kanamycin, streptomycin, capreomycin, and viomycin using 90 consecutive clinical isolates and 21 resistant strains. Overall, the MIC variation between and within runs did not exceed +/-1 MIC dilution step, and validation of MIC values in Bactec 960 MGIT demonstrated good agreement. Tentative ECOFFs defining the wild type were established for all investigated drugs, including amikacin and viomycin, which currently lack susceptibility breakpoints for 7H10. Five out of seven amikacin- and kanamycin-resistant isolates were classified as susceptible to capreomycin according to the current critical concentration (10 mg/liter) but were non-wild type according to the ECOFF (4 mg/liter), suggesting that the critical concentration may be too high. All amikacin- and kanamycin-resistant isolates were clearly below the ECOFF for viomycin, and two of them were below the ECOFF for streptomycin, indicating that these two drugs may be considered for treatment of amikacin-resistant strains. Pharmacodynamic indices (peak serum concentration [Cmax]/MIC) were more favorable for amikacin and viomycin compared to kanamycin and capreomycin. In conclusion, our data emphasize the importance of establishing wild-type MIC distributions for improving the quality of drug susceptibility testing against Mycobacterium tuberculosis.

  12. Wild-Type MIC Distributions for Aminoglycoside and Cyclic Polypeptide Antibiotics Used for Treatment of Mycobacterium tuberculosis Infections▿

    PubMed Central

    Juréen, P.; Ängeby, K.; Sturegård, E.; Chryssanthou, E.; Giske, C. G.; Werngren, J.; Nordvall, M.; Johansson, A.; Kahlmeter, G.; Hoffner, S.; Schön, T.

    2010-01-01

    The aminoglycosides and cyclic polypeptides are essential drugs in the treatment of multidrug-resistant tuberculosis, underscoring the need for accurate and reproducible drug susceptibility testing (DST). The epidemiological cutoff value (ECOFF) separating wild-type susceptible strains from non-wild-type strains is an important but rarely used tool for indicating susceptibility breakpoints against Mycobacterium tuberculosis. In this study, we established wild-type MIC distributions on Middlebrook 7H10 medium for amikacin, kanamycin, streptomycin, capreomycin, and viomycin using 90 consecutive clinical isolates and 21 resistant strains. Overall, the MIC variation between and within runs did not exceed ±1 MIC dilution step, and validation of MIC values in Bactec 960 MGIT demonstrated good agreement. Tentative ECOFFs defining the wild type were established for all investigated drugs, including amikacin and viomycin, which currently lack susceptibility breakpoints for 7H10. Five out of seven amikacin- and kanamycin-resistant isolates were classified as susceptible to capreomycin according to the current critical concentration (10 mg/liter) but were non-wild type according to the ECOFF (4 mg/liter), suggesting that the critical concentration may be too high. All amikacin- and kanamycin-resistant isolates were clearly below the ECOFF for viomycin, and two of them were below the ECOFF for streptomycin, indicating that these two drugs may be considered for treatment of amikacin-resistant strains. Pharmacodynamic indices (peak serum concentration [Cmax]/MIC) were more favorable for amikacin and viomycin compared to kanamycin and capreomycin. In conclusion, our data emphasize the importance of establishing wild-type MIC distributions for improving the quality of drug susceptibility testing against Mycobacterium tuberculosis. PMID:20237102

  13. The effect of vitamin A and zinc supplementation on treatment outcomes in pulmonary tuberculosis: a randomized controlled trial.

    PubMed

    Visser, Marianne E; Grewal, Harleen Ms; Swart, Elizabeth C; Dhansay, Muhammad A; Walzl, Gerhard; Swanevelder, Sonja; Lombard, Carl; Maartens, Gary

    2011-01-01

    Low serum concentrations of vitamin A and zinc are common in tuberculosis and may have an adverse effect on host cell-mediated responses. The role of adjunctive micronutrient supplementation on treatment outcomes is uncertain. The objective was to assess the efficacy of vitamin A and zinc supplementation on sputum smear and culture conversion and time to culture detection in adults with sputum smear-positive pulmonary tuberculosis. Participants attending a primary care tuberculosis clinic in Cape Town, South Africa, were randomly assigned to receive micronutrients (single dose of 200,000 IU retinyl palmitate plus 15 mg Zn/d for 8 wk) or matching placebo. Sputum was collected weekly for 8 wk for auramine staining and culture on liquid media (BACTEC MGIT 960; Becton Dickinson, Sparks, MD). Performance status, chest radiographs, and anthropometric measures were assessed at baseline and again at 8 wk. The participants (n = 154) were randomly assigned to the micronutrient (n = 77) or placebo (n = 77) group. Twenty participants were HIV infected (13%), and 12 participants had an unknown HIV status (8%). No differences in time to smear or culture conversion were observed between the treatment groups by Kaplan-Meier analysis (P = 0.15 and P = 0.38, respectively; log-rank test). Log-logistic regression analysis found no significant group interaction effect in time to culture detection over the 8-wk period (P = 0.32). No significant differences in weight gain (2.3 ± 3.5 compared with 2.2 ± 2.4 kg, P = 0.68) or radiologic resolution were observed between the treatment groups. Supplementation with vitamin A and zinc did not affect treatment outcomes in participants with pulmonary tuberculosis at 8 wk. This trial was registered at controlled-trials.com as ISRCTN80852505.

  14. Clinical relevance of molecular identification of microorganisms and detection of antimicrobial resistance genes in bloodstream infections of paediatric cancer patients.

    PubMed

    Carlesse, Fabianne; Cappellano, Paola; Quiles, Milene Gonçalves; Menezes, Liana Carballo; Petrilli, Antonio Sérgio; Pignatari, Antonio Carlos

    2016-09-01

    Bloodstream infections (BSIs) are the major cause of mortality in cancer patients. Molecular techniques are used for rapid diagnosis of BSI, allowing early therapy and improving survival. We aimed to establish whether real-time quantitative polymerase chain reaction (qPCR) could improve early diagnosis and therapy in paediatric cancer patients, and describe the predominant pathogens of BSI and their antimicrobial susceptibility. Blood samples were processed by the BACTEC system and microbial identification and susceptibility tests were performed by the Phoenix system. All samples were screened by multiplex 16 s rDNA qPCR. Seventeen species were evaluated using sex-specific TaqMan probes and resistance genes blaSHV, blaTEM, blaCTX, blaKPC, blaIMP, blaSPM, blaVIM, vanA, vanB and mecA were screened by SYBR Green reactions. Therapeutic efficacy was evaluated at the time of positive blood culture and at final phenotypic identification and antimicrobial susceptibility results. We analyzed 69 episodes of BSI from 64 patients. Gram-positive bacteria were identified in 61 % of the samples, Gram-negative bacteria in 32 % and fungi in 7 %. There was 78.2 % of agreement between the phenotypic and molecular methods in final species identification. The mecA gene was detected in 81.4 % of Staphylococcus spp., and 91.6 % were concordant with the phenotypic method. Detection of vanA gene was 100 % concordant. The concordance for Gram-negative susceptibilities was 71.4 % for Enterobacteriaceae and 50 % for Pseudomonas aeruginosa. Therapy was more frequently inadequate in patients who died, and the molecular test was concordant with the phenotypic susceptibility test in 50 %. qPCR has potential indication for early identification of pathogens and antimicrobial resistance genes from BSI in paediatric cancer patients and may improve antimicrobial therapy.

  15. Detection of Mycobacterium avium subspecies paratuberculosis in tie-stall dairy herds using a standardized environmental sampling technique and targeted pooled samples.

    PubMed

    Arango-Sabogal, Juan C; Côté, Geneviève; Paré, Julie; Labrecque, Olivia; Roy, Jean-Philippe; Buczinski, Sébastien; Doré, Elizabeth; Fairbrother, Julie H; Bissonnette, Nathalie; Wellemans, Vincent; Fecteau, Gilles

    2016-07-01

    Mycobacterium avium ssp. paratuberculosis (MAP) is the etiologic agent of Johne's disease, a chronic contagious enteritis of ruminants that causes major economic losses. Several studies, most involving large free-stall herds, have found environmental sampling to be a suitable method for detecting MAP-infected herds. In eastern Canada, where small tie-stall herds are predominant, certain conditions and management practices may influence the survival and transmission of MAP and recovery (isolation). Our objective was to estimate the performance of a standardized environmental and targeted pooled sampling technique for the detection of MAP-infected tie-stall dairy herds. Twenty-four farms (19 MAP-infected and 5 non-infected) were enrolled, but only 20 were visited twice in the same year, to collect 7 environmental samples and 2 pooled samples (sick cows and cows with poor body condition). Concurrent individual sampling of all adult cows in the herds was also carried out. Isolation of MAP was achieved using the MGIT Para TB culture media and the BACTEC 960 detection system. Overall, MAP was isolated in 7% of the environmental cultures. The sensitivity of the environmental culture was 44% [95% confidence interval (CI): 20% to 70%] when combining results from 2 different herd visits and 32% (95% CI: 13% to 57%) when results from only 1 random herd visit were used. The best sampling strategy was to combine samples from the manure pit, gutter, sick cows, and cows with poor body condition. The standardized environmental sampling technique and the targeted pooled samples presented in this study is an alternative sampling strategy to costly individual cultures for detecting MAP-infected tie-stall dairies. Repeated samplings may improve the detection of MAP-infected herds.

  16. Efficient, Validated Method for Detection of Mycobacterial Growth in Liquid Culture Media by Use of Bead Beating, Magnetic-Particle-Based Nucleic Acid Isolation, and Quantitative PCR

    PubMed Central

    Waldron, Anna M.; Begg, Douglas J.; de Silva, Kumudika; Purdie, Auriol C.; Whittington, Richard J.

    2015-01-01

    Pathogenic mycobacteria are difficult to culture, requiring specialized media and a long incubation time, and have complex and exceedingly robust cell walls. Mycobacterium avium subsp. paratuberculosis (MAP), the causative agent of Johne's disease, a chronic wasting disease of ruminants, is a typical example. Culture of MAP from the feces and intestinal tissues is a commonly used test for confirmation of infection. Liquid medium offers greater sensitivity than solid medium for detection of MAP; however, support for the BD Bactec 460 system commonly used for this purpose has been discontinued. We previously developed a new liquid culture medium, M7H9C, to replace it, with confirmation of growth reliant on PCR. Here, we report an efficient DNA isolation and quantitative PCR methodology for the specific detection and confirmation of MAP growth in liquid culture media containing egg yolk. The analytical sensitivity was at least 104-fold higher than a commonly used method involving ethanol precipitation of DNA and conventional PCR; this may be partly due to the addition of a bead-beating step to manually disrupt the cell wall of the mycobacteria. The limit of detection, determined using pure cultures of two different MAP strains, was 100 to 1,000 MAP organisms/ml. The diagnostic accuracy was confirmed using a panel of cattle fecal (n = 54) and sheep fecal and tissue (n = 90) culture samples. This technique is directly relevant for diagnostic laboratories that perform MAP cultures but may also be applicable to the detection of other species, including M. avium and M. tuberculosis. PMID:25609725

  17. Human brucellosis among pyrexia of unknown origin cases and occupationally exposed individuals in Goa Region, India.

    PubMed

    Pathak, Ajay D; Dubal, Zunjar B; Doijad, Swapnil; Raorane, Abhay; Rodrigues, Savio; Naik, Rajeshwar; Naik-Gaonkar, Shraddha; Kalorey, Dewanand R; Kurkure, Nitin V; Naik, Rajesh; Barbuddhe, Sukhadeo B

    2014-01-01

    Brucellosis is a widespread zoonotic infection. This disease is endemic in many parts of Asia, including India. Brucellosis is a major cause of pyrexia of unknown origin (PUO). Persons exposed to infected animals or contaminated animal products are at high risk. Seropositivity among animal handlers, veterinarians and dairy workers has been documented in India. Thus, the present study was aimed to determine prevalence of brucellosis among PUO cases and occupationally exposed individuals. In this study, serum samples (n=282) from cases of pyrexia of unknown origin (PUO) (n=243), and occupationally exposed individuals (n=39) were collected and tested for brucellosis by Rose Bengal plate test (RBPT), serum agglutination test (SAT), indirect ELISA, IgG and IgM ELISA. Blood culture for isolation of Brucella was performed for 10 serologically positive patients using BACTEC 9050 automated blood culture system. Biochemical tests and PCR techniques were used for confirmation of the isolates. Of the samples tested, 4.25%, 3.54%, 6.02% and 4.96% samples were positive by RBPT, SAT, indirect ELISA and IgG ELISA, respectively. None of the sample was positive for IgM ELISA. Of the 10 blood samples cultured bacteriologically, one Brucella isolate was recovered. The isolate was confirmed as Brucella abortus. Amplification of the bcsp31 and IS711 genes was also observed. Seropositivity for brucellosis was observed among PUO cases, animal handlers and dairy workers in Goa, India. The serological tests showed variable results. One Brucella isolate was obtained by performing blood culture. Confirmation of the case was done rapidly using molecular tools. General awareness about clinical symptoms should be increased which will improve proper diagnosis within short time frame.

  18. Mycobacterium avium subspecies paratuberculosis isolates from sheep and goats show reduced persistence in bovine macrophages than cattle, bison, deer and wild boar strains regardless of genotype.

    PubMed

    Abendaño, Naiara; Sevilla, Iker A; Prieto, José Miguel; Garrido, Joseba M; Juste, Ramon A; Alonso-Hearn, Marta

    2013-05-03

    Assessment of the virulence of isolates of Mycobacterium avium subsp. paratuberculosis (Map) exhibiting distinct genotypes and isolated from different hosts may help to clarify the degree to which clinical manifestations of the disease in cattle can be attributed to bacterial or to host factors. The objective of this study was to test the ability of 10 isolates of Map representing distinct genotypes and isolated from domestic (cattle, sheep, and goat), and wildlife animal species (fallow deer, deer, wild boar, and bison) to enter and grow in bovine macrophages. The isolates were previously typed using IS1311 PCR followed by restriction endonuclease analysis into types C, S or B. Intracellular growth of the isolates in a bovine macrophage-like cell line (BoMac) and in primary bovine monocyte-derived macrophages (MDM) was evaluated by quantification of CFU numbers in the initial inoculum and inside of the host cells at 2h and 7 d p.i. using an automatic liquid culture system (Bactec MGIT 960). Individual data illustrated that growth was less variable in BoMac than in MDM cells. All the isolates from goat and sheep hosts persisted within BoMac cells in lower CFU numbers than the other tested isolates after 7 days of infection regardless of genotype. In addition, BoMac cells exhibited differential inflammatory, apoptotic and destructive responses when infected with a bovine or an ovine isolate; which correlated with the differential survival of these strains within BoMac cells. Our results indicated that the survival of the tested Map isolates within bovine macrophages is associated with the specific host from which the isolates were initially isolated. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Efficient, validated method for detection of mycobacterial growth in liquid culture media by use of bead beating, magnetic-particle-based nucleic acid isolation, and quantitative PCR.

    PubMed

    Plain, Karren M; Waldron, Anna M; Begg, Douglas J; de Silva, Kumudika; Purdie, Auriol C; Whittington, Richard J

    2015-04-01

    Pathogenic mycobacteria are difficult to culture, requiring specialized media and a long incubation time, and have complex and exceedingly robust cell walls. Mycobacterium avium subsp. paratuberculosis (MAP), the causative agent of Johne's disease, a chronic wasting disease of ruminants, is a typical example. Culture of MAP from the feces and intestinal tissues is a commonly used test for confirmation of infection. Liquid medium offers greater sensitivity than solid medium for detection of MAP; however, support for the BD Bactec 460 system commonly used for this purpose has been discontinued. We previously developed a new liquid culture medium, M7H9C, to replace it, with confirmation of growth reliant on PCR. Here, we report an efficient DNA isolation and quantitative PCR methodology for the specific detection and confirmation of MAP growth in liquid culture media containing egg yolk. The analytical sensitivity was at least 10(4)-fold higher than a commonly used method involving ethanol precipitation of DNA and conventional PCR; this may be partly due to the addition of a bead-beating step to manually disrupt the cell wall of the mycobacteria. The limit of detection, determined using pure cultures of two different MAP strains, was 100 to 1,000 MAP organisms/ml. The diagnostic accuracy was confirmed using a panel of cattle fecal (n=54) and sheep fecal and tissue (n=90) culture samples. This technique is directly relevant for diagnostic laboratories that perform MAP cultures but may also be applicable to the detection of other species, including M. avium and M. tuberculosis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Impact of fgd1 and ddn Diversity in Mycobacterium tuberculosis Complex on In Vitro Susceptibility to PA-824 ▿ ‡

    PubMed Central

    Feuerriegel, Silke; Köser, Claudio U.; Baù, Davide; Rüsch-Gerdes, Sabine; Summers, David K.; Archer, John A. C.; Marti-Renom, Marc A.; Niemann, Stefan

    2011-01-01

    PA-824 is a promising drug candidate for the treatment of tuberculosis (TB). It is in phase II clinical trials as part of the first newly designed regimen containing multiple novel antituberculosis drugs (PA-824 in combination with moxifloxacin and pyrazinamide). However, given that the genes involved in resistance against PA-824 are not fully conserved in the Mycobacterium tuberculosis complex (MTBC), this regimen might not be equally effective against different MTBC genotypes. To investigate this question, we sequenced two PA-824 resistance genes (fgd1 [Rv0407] and ddn [Rv3547]) in 65 MTBC strains representing major phylogenetic lineages. The MICs of representative strains were determined using the modified proportion method in the Bactec MGIT 960 system. Our analysis revealed single-nucleotide polymorphisms in both genes that were specific either for several genotypes or for individual strains, yet none of these mutations significantly affected the PA-824 MICs (≤0.25 μg/ml). These results were supported by in silico modeling of the mutations identified in Fgd1. In contrast, “Mycobacterium canettii” strains displayed a higher MIC of 8 μg/ml. In conclusion, we found a large genetic diversity in PA-824 resistance genes that did not lead to elevated PA-824 MICs. In contrast, M. canettii strains had MICs that were above the plasma concentrations of PA-824 documented so far in clinical trials. As M. canettii is also intrinsically resistant against pyrazinamide, new regimens containing PA-824 and pyrazinamide might not be effective in treating M. canettii infections. This finding has implications for the design of multiple ongoing clinical trials. PMID:21930879

  1. A simple whole cell based high throughput screening protocol using Mycobacterium bovis BCG for inhibitors against dormant and active tubercle bacilli.

    PubMed

    Khan, Arshad; Sarkar, Dhiman

    2008-04-01

    This study aimed at developing a whole cell based high throughput screening protocol to identify inhibitors against both active and dormant tubercle bacilli. A respiratory type of nitrate reductase (NarGHJI), which was induced during dormancy, could reflect the viability of dormant bacilli of Mycobacterium bovis BCG in microplate adopted model of in vitro dormancy. Correlation between reduction in viability and nitrate reductase activity was seen clearly when dormant stage inhibitor metronidazole and itaconic anhydride were applied in this in vitro microplate model. Active replicating stage could also be monitored in the same assay by measuring the A(620) of the culture. MIC values of 0.08, 0.075, 0.3 and 3.0 microg/ml, determined through monitoring A(620) in this assay for rifampin, isoniazid, streptomycin and ethambutol respectively, were well in agreement with previously reported by BACTEC and Bio-Siv assays. S/N ratio and Z' factor for the assay were 8.5 and 0.81 respectively which indicated the robustness of the protocol. Altogether the assay provides an easy, inexpensive, rapid, robust and high content screening tool to search novel antitubercular molecules against both active and dormant bacilli.

  2. Anti-tubercular agents from Glycyrrhiza glabra.

    PubMed

    Kalani, Komal; Chaturvedi, Vinita; Alam, Sarfaraz; Khan, Feroz; Srivastava, Santosh Kumar

    2015-01-01

    Bioactivity guided isolation of Glycyrrhiza glabra (Leguminosae / Fabaceae) roots resulted in the characterization of 18β-glycyrrhetinic acid as a major anti-tubercular agent. Further, GA-1 was semi-synthetically converted into its nine derivatives, which were in-vitro evaluated for their antitubercular potential against Mycobacterium tuberculosis H37Rv using BACTEC-460 radiometric susceptibility assay. All the derivatives were active, but the benzylamide (GA-8, MIC 12.5μg/ml) and ethyl oxylate (GA-3, MIC 25.0 μg/ml) derivatives were significantly active against the pathogen. This was further supported by the molecular docking studies, which showed adequate docking (LibDock) scores for GA-3 (120.3) and GA-8 (112.6) with respect to the standard anti-tubercular drug, rifampicin (92.94) on the DNA-directed RNA polymerase subunit beta (rpoB) target site. Finally, the in silico pharmacokinetic and drug-likeness studies showed that GA-3 and GA- 8 possesses drug-like properties. This is the first ever report on the anti-tubercular potential of GA and its derivatives. These results may be of great help in anti-tubercular drug development from a very common, inexpensive, and non toxic natural product.

  3. Xpert MTB/RIF assay can be used on archived gastric aspirate and induced sputum samples for sensitive diagnosis of paediatric tuberculosis.

    PubMed

    Singh, Sarman; Singh, Amit; Prajapati, Suneel; Kabra, Sushil K; Lodha, Rakesh; Mukherjee, Aparna; Singh, Varinder; Hesseling, Anneke C; Grewal, Harleen M S

    2015-09-29

    Tuberculosis (TB) in children is neglected, mainly due to lack of sensitive diagnostic tools. Recently Xpert MTB/RIF assay has revolutionized the diagnostic field, but its usefulness in pediatric TB has not been reported from India and no report is available on its use on long term archived samples. We recruited 130 pediatric patients with probable intrathoracic tuberculosis and their gastric aspirate (GA) and induced sputum (IS) samples on 2 consecutive days were collected between January 2009 and December 2012. All samples (n = 520) were subjected to smear examination, BACTEC-MGIT culture and in-house multiplex PCR. An aliquot of each sample was stored at -80 °C and tested in Xpert MTB/RIF assay in 2013. Sample wise and patient wise detection rate of smear microscopy was 4.4 % and 10 %, while for BACTEC-MGIT culture this rate was 24.4 % and 46.9 %, respectively. Of the 130 day 1 GA samples, 31.5 % and 27.7 % day 2 GA samples were culture positive. Only 17.7 % GA samples were positive on both days. Of the 130 IS samples collected on day 1 and day 2, 15.4 % and 23.1 % samples were culture positive. A combination of GA and IS yielded best results. Combining both GA and IS, the overall sensitivity of Xpert MTB/RIF on smear and culture positive samples was 95.6 %. In smear negative and culture positive samples its sensitivity was 62.5 %. The duration of sample storage impacted the Xpert MTB/RIF test performance (p = 0.0001). In smear positive samples stored for 650-849 days, its sensitivity was 85.7 % and 77.1 % for IS and GA samples which dropped to 33.3 % and 50 %, respectively, if stored for more than 1050 days. Confirmatory diagnosis of tuberculosis particularly in children is a medical challenge. No laboratory or radiological test can reach to a satisfactory level of diagnostic sensitivity. However, in this study we found that combination of multiple samples and multiple diagnostic tests can give much better yield, though not optimum. In present study, combination of 2 gastric aspirates (GA) and 2 induced sputum (IS) samples collected on two consecutive days, and tested on three diagnostic methods yielded a significantly high detection rate. Despite long term storage, the overall sensitivity of Xpert MTB/RIF on smear and -culture positive samples remained very high. But after storing these samples under subfreezing conditions the sensitivity of Xpert MTB/RIF decreased significantly. This is expected because even if the sample is smear and culture positive, the count of surviving mycobacteria goes down, after several years this count can reach to a undetectable level. This report shows that smear and culture positive samples stored at subfreezing conditions for several years can be used in the Xpert MTB/RIF assay, while maintaining appreciable diagnostic test sensitivity and specificity.

  4. Differential inhibition of adenylylated and deadenylylated forms of M. tuberculosis glutamine synthetase as a drug discovery platform

    PubMed Central

    Theron, A.; Roth, R. L.; Hoppe, H.; Parkinson, C.; van der Westhuyzen, C. W.; Stoychev, S.; Wiid, I.; Pietersen, R. D.; Baker, B.

    2017-01-01

    Glutamine synthetase is a ubiquitous central enzyme in nitrogen metabolism that is controlled by up to four regulatory mechanisms, including adenylylation of some or all of the twelve subunits by adenylyl transferase. It is considered a potential therapeutic target for the treatment of tuberculosis, being essential for the growth of Mycobacterium tuberculosis, and is found extracellularly only in the pathogenic Mycobacterium strains. Human glutamine synthetase is not regulated by the adenylylation mechanism, so the adenylylated form of bacterial glutamine synthetase is of particular interest. Previously published reports show that, when M. tuberculosis glutamine synthetase is expressed in Escherichia coli, the E. coli adenylyl transferase does not optimally adenylylate the M. tuberculosis glutamine synthetase. Here, we demonstrate the production of soluble adenylylated M. tuberulosis glutamine synthetase in E. coli by the co-expression of M. tuberculosis glutamine synthetase and M. tuberculosis adenylyl transferase. The differential inhibition of adenylylated M. tuberulosis glutamine synthetase and deadenylylated M. tuberulosis glutamine synthetase by ATP based scaffold inhibitors are reported. Compounds selected on the basis of their enzyme inhibition were also shown to inhibit M. tuberculosis in the BACTEC 460TB™ assay as well as the intracellular inhibition of M. tuberculosis in a mouse bone-marrow derived macrophage assay. PMID:28972974

  5. A novel automatic molecular test for detection of multidrug resistance tuberculosis in sputum specimen: A case control study.

    PubMed

    Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L

    2017-07-01

    MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.

  6. Direct Detection by the Xpert MTB/RIF Assay and Characterization of Multi and Poly Drug-Resistant Tuberculosis in Guinea-Bissau, West Africa

    PubMed Central

    Ponce, Gema; Sanca, Lilica; Mané, Morto; Armada, Ana; Machado, Diana; Vieira, Fina; Gomes, Victor F.; Martins, Elisabete; Colombatti, Raffaella; Riccardi, Fabio; Perdigão, João; Sotero, Joana; Portugal, Isabel; Couto, Isabel; Atouguia, Jorge; Rodrigues, Amabélia; Viveiros, Miguel

    2015-01-01

    Background This study aimed to evaluate the usefulness of the Xpert MTB/RIF assay for the rapid direct detection of M. tuberculosis complex (MTBC) strains and rifampicin resistance associated mutations in a resource-limited setting such as Guinea-Bissau and its implications in the management of tuberculosis (TB) and drug resistant tuberculosis, complementing the scarce information on resistance and genotypic diversity of MTBC strains in this West African country. Methods and Results This cross-sectional prospective study included 100 consecutive TB patients with positive acid-fast smears at two months of anti-tuberculosis treatment or in a re-treatment situation, between May and December 2012. Resistance to rifampicin was detected using the GeneXpert system and the Xpert MTB/RIF assay. MTBC isolates obtained with the BACTEC MGIT 960 system were tested for susceptibility to first- and second-line anti-tuberculosis drugs. Overall, the prevalence of multidrug-resistant tuberculosis (MDR-TB) was found to be 9 cases. Of these, 67% (6 patients) of confirmed MDR-TB cases had no past history of TB treatment and 33% (3 patients) were previously treated cases. Extensively drug-resistant TB was not found. Molecular typing of the MDR-TB strains revealed recent transmission patterns of imported MDR strains. Conclusions The Xpert MTB/RIF assay was reliable for the detection of rifampicin resistant MTBC strains directly from sputum samples of patients undergoing first-line treatment for two months, being more trustworthy than the simple presence of acid-fast bacilli in the smear. Its implementation is technically simple, does not require specialized laboratory infrastructures and is suitable for resource-limited settings when a regular source of electricity and maintenance is available as well as financial and operation sustainability is guaranteed by the health authorities. A high prevalence of MDR-TB among patients at risk of MDR-TB after two months of first-line treatment was found, in support of the WHO recommendations for its use in the management of this risk group. PMID:26017968

  7. Differential fluorescent staining method for detection of bacteria in blood cultures, cerebrospinal fluid and other clinical specimens.

    PubMed

    Fazii, P; Ciancaglini, E; Riario Sforza, G

    2002-05-01

    The aim of this study was to evaluate a differential staining method to distinguish gram-positive from gram-negative bacteria in fluorescence. The method is based on two fluorochromes, one acting in the wavelength of red, i.e. the acridine orange, and another acting in the wavelength of green, i.e. the fluorescein. With this method, gram-positive bacteria appear yellow and gram-negative bacteria appear green. In view of the importance of a rapid aetiological diagnosis in cases of septicaemia, the differential staining method in fluorescence was compared with Gram stain for the detection of bacteria in blood. Of 5,820 blood cultures entered into the study and identified by the Bactec 9120 fluorescent series instrument (Becton Dickinson Europe, France), 774 were positive. Of the 774 positive cultures, 689 yielded only a single organism. The differential staining method in fluorescence detected 626 of the 689 cultures, while Gram stain detected 468. On the basis of these results, the sensitivity of the differential staining method in fluorescence was 90.9%, while that of Gram stain was 67.9%. The difference between the two methods was statistically significant ( P<0.001). The differential fluorescent staining method was more sensitive than Gram stain in the detection of bacteria in blood cultures during the incubation period. This technique provides a rapid, simple and highly sensitive staining method that can be used in conjunction with subculture methods. Whereas subculture requires an incubation period of 18-24 h, the fluorescent staining technique can detect bacteria on the same day that smears are prepared and examined. The differential fluorescent staining method was also evaluated for its ability to detect microorganisms in cerebrospinal fluid and other clinical specimens. The microorganisms were easily detected, even when bacterial counts in the specimens were low.

  8. A cross-sectional study of tuberculosis drug resistance among previously treated patients in a tertiary hospital in Accra, Ghana: public health implications of standardized regimens.

    PubMed

    Forson, Audrey; Kwara, Awewura; Kudzawu, Samuel; Omari, Michael; Otu, Jacob; Gehre, Florian; de Jong, Bouke; Antonio, Martin

    2018-04-02

    Mycobacterium tuberculosis drug resistance is a major challenge to the use of standardized regimens for tuberculosis (TB) therapy, especially among previously treated patients. We aimed to investigate the frequency and pattern of drug resistance among previously treated patients with smear-positive pulmonary tuberculosis at the Korle-Bu Teaching Hospital Chest Clinic, Accra. This was a cross-sectional survey of mycobacterial isolates from previously treated patients referred to the Chest Clinic Laboratory between October 2010 and October 2013. The Bactec MGIT 960 system for mycobactrerial culture and drug sensitivity testing (DST) was used for sputum culture of AFB smear-positive patients with relapse, treatment failure, failure of smear conversion, or default. Descriptive statistics were used to summarize patient characteristics, and frequency and patterns of drug resistance. A total of 112 isolates were studied out of 155 from previously treated patients. Twenty contaminated (12.9%) and 23 non-viable isolates (14.8%) were excluded. Of the 112 studied isolates, 53 (47.3%) were pan-sensitive to all first-line drugs tested Any resistance (mono and poly resistance) to isoniazid was found in 44 isolates (39.3%) and any resistance to streptomycin in 43 (38.4%). Thirty-one (27.7%) were MDR-TB. Eleven (35.5%) out of 31 MDR-TB isolates were pre-XDR. MDR-TB isolates were more likely than non-MDR isolates to have streptomycin and ethambutol resistance. The main findings of this study were the high prevalence of MDR-TB and streptomycin resistance among previously treated TB patients, as well as a high prevalence of pre-XDR-TB among the MDR-TB patients, which suggest that first-line and second-line DST is essential to aid the design of effective regimens for these groups of patients in Ghana.

  9. Sample preparation method influences direct identification of anaerobic bacteria from positive blood culture bottles using MALDI-TOF MS.

    PubMed

    Jeverica, Samo; Nagy, Elisabeth; Mueller-Premru, Manica; Papst, Lea

    2018-05-15

    Rapid detection and identification of anaerobic bacteria from blood is important to adjust antimicrobial therapy by including antibiotics with activity against anaerobic bacteria. Limited data is available about direct identification of anaerobes from positive blood culture bottles using MALDI-TOF mass spectrometry (MS). In this study, we evaluated the performance of two sample preparation protocols for direct identification of anaerobes from positive blood culture bottles, the MALDI Sepsityper kit (Sepsityper) and the in-house saponin (saponin) method. Additionally, we compared two blood culture bottle types designed to support the growth of anaerobic bacteria, the BacT/ALERT-FN Plus (FN Plus) and the BACTEC-Lytic (Lytic), and their influence on direct identification. A selection of 30 anaerobe strains belonging to 22 different anaerobic species (11 reference strains and 19 clinical isolates) were inoculated to 2 blood culture bottle types in duplicate. In total, 120 bottles were inoculated and 99.2% (n = 119) signalled growth within 5 days of incubation. The Sepsityper method correctly identified 56.3% (n = 67) of anaerobes, while the saponin method correctly identified 84.9% (n = 101) of anaerobes with at least log(score) ≥1.6 (low confidence correct identification), (p < 0.001). Gram negative anaerobes were better identified with the saponin method (100% vs. 46.5%; p < 0.001), while Gram positive anaerobes were better identified with the Sepsityper method (70.8% vs. 62.5%; p = 0.454). Average log(score) values among only those isolates that were correctly identified simultaneously by both sample preparation methods were 2.119 and 2.029 in favour of the Sepsityper method, (p = 0.019). The inoculated bottle type didn't influence the performance of the two sample preparation methods. We confirmed that direct identification from positive blood culture bottles with MALDI-TOF MS is reliable for anaerobic bacteria. However, the results are influenced by the sample preparation method used. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. In vitro activity of roxithromycin against the Mycobacterium tuberculosis complex.

    PubMed Central

    Rastogi, N; Goh, K S; Ruiz, P; Casal, M

    1995-01-01

    Roxithromycin has recently been shown to possess significant in vitro activity against a variety of atypical mycobacteria such as the M. avium complex, M. scrofulaceum, M. szulgai, M. malmoense, M. xenopi, M. marinum, and M. kansasii and rare pathogens like M. chelonei and M. fortuitum. In the present investigation, screening of its in vitro activity was further extended by testing it against 34 strains belonging to the M. tuberculosis complex (including M. tuberculosis, M. africanum, M. bovis, and M. bovis BCG). The MICs were determined by the radiometric BACTEC 460-TB methodology at pHs of both 6.8 and 7.4, as well as with 7H10 agar medium by the 1% proportion method. With the exception of M. bovis BCG (MIC ranges, 0.5 to 4 micrograms/ml at pH 6.8 and 0.25 to 2 micrograms/ml at pH 7.4), MICs for all of the isolates were significantly greater (MIC ranges, 32 to > 64 micrograms/ml at pH 6.8 and 16 to > 32 micrograms/ml at pH 7.4) than those reported previously for atypical mycobacteria. Roxithromycin MICs of 64 or > 64 micrograms/ml for all of the M. tuberculosis isolates screened were found by the 7H10 agar medium method. Roxithromycin, however, showed a pH-dependent bactericidal effect against M. tuberculosis because the drug was relatively more active when it was used at pH 7.4 than when it was used at pH 6.8. We conclude that roxithromycin per se is not a drug of choice for the treatment of M. tuberculosis infection or disease; however, considering its pharmacokinetics, eventual anti-tubercle bacillus activity in an in vivo system cannot yet be excluded. We suggest that the use of roxithromycin in chemoprophylactic regimens for the prevention of opportunistic infections (including M. avium complex infections) in patients with AIDS should be carefully monitored, and patients should be enrolled in such a regimen only after it has been excluded that the patient das an underlying infection of disease caused by M. tuberculosis. PMID:7625806

  11. Distribution of Spoligotyping Defined Genotypic Lineages among Drug-Resistant Mycobacterium tuberculosis Complex Clinical Isolates in Ankara, Turkey

    PubMed Central

    Kisa, Ozgul; Tarhan, Gulnur; Gunal, Selami; Albay, Ali; Durmaz, Riza; Saribas, Zeynep; Zozio, Thierry; Alp, Alpaslan; Ceyhan, Ismail; Tombak, Ahmet; Rastogi, Nalin

    2012-01-01

    Background Investigation of genetic heterogeneity and spoligotype-defined lineages of drug-resistant Mycobacterium tuberculosis clinical isolates collected during a three-year period in two university hospitals and National Tuberculosis Reference and Research Laboratory in Ankara, Turkey. Methods and Findings A total of 95 drug-resistant M. tuberculosis isolates collected from three different centers were included in this study. Susceptibility testing of the isolates to four major antituberculous drugs was performed using proportion method on Löwenstein–Jensen medium and BACTEC 460-TB system. All clinical isolates were typed by using spoligotyping and IS6110-restriction fragment length polymorphism (RFLP) methods. Seventy-three of the 95 (76.8%) drug resistant M. tuberculosis isolates were isoniazid-resistant, 45 (47.4%) were rifampicin-resistant, 32 (33.7%) were streptomycin-resistant and 31 (32.6%) were ethambutol-resistant. The proportion of multidrug-resistant isolates (MDR) was 42.1%. By using spoligotyping, 35 distinct patterns were observed; 75 clinical isolates were grouped in 15 clusters (clustering rate of 79%) and 20 isolates displayed unique patterns. Five of these 20 unique patterns corresponded to orphan patterns in the SITVIT2 database, while 4 shared types containing 8 isolates were newly created. The most prevalent M. tuberculosis lineages were: Haarlem (23/95, 24.2%), ill-defined T superfamily (22/95, 23.2%), the Turkey family (19/95, 20%; previously designated as LAM7-TUR), Beijing (6/95, 6.3%), and Latin-America & Mediterranean (LAM, 5/95 or 5.3%), followed by Manu (3/95, 3.2%) and S (1/95, 1%) lineages. Four of the six Beijing family isolates (66.7%) were MDR. A combination of IS6110-RFLP and spoligotyping reduced the clustering rate from 79% to 11.5% among the drug resistant isolates. Conclusions The results obtained showed that ill-defined T, Haarlem, the Turkey family (previously designated as LAM7-TUR family with high phylogeographical specifity for Turkey), Beijing and LAM were predominant lineages observed in almost 80% of the drug-Resistant M. tuberculosis complex clinical isolates in Ankara, Turkey. PMID:22279583

  12. Routine use of PCR-restriction fragment length polymorphism analysis for identification of mycobacteria growing in liquid media.

    PubMed Central

    Taylor, T B; Patterson, C; Hale, Y; Safranek, W W

    1997-01-01

    A PCR-restriction fragment length polymorphism (PCR-RFLP) procedure capable of rapidly identifying 28 species of clinically encountered mycobacteria was evaluated for use in the routine identification of acid-fast isolates growing in BACTEC 12B and 13A liquid media. PCR-RFLP identified 100 of 103 acid-fast isolates recovered from 610 patient specimens submitted for culture during the study. The three isolates unidentifiable by PCR-RFLP produced restriction patterns not included in the PCR-RFLP algorithm and could therefore not be assigned to a species. These isolates were characterized by their morphologic and biochemical characteristics. Two of the isolates were identified as M. terrae complex and M. gordonae. The third isolate could not be definitively identified and could only be characterized as a Mycobacterium sp. most closely resembling M. chelonae. PCR-RFLP identifications agreed with the conventional identifications for 96 of the 100 isolates identified by PCR-RFLP. Subsequent identification of the four discordant isolates by gas chromatography analysis supported the PCR-RFLP identification of each isolate. Amplification products were also obtained from isolates of Streptococcus albus and Rhodococcus equi recovered from patient specimens; however, the restriction patterns of these nonmycobacterial species did not resemble the patterns of any mycobacterial species included in the PCR-RFLP algorithm. PCR-RFLP seems to be a reliable procedure for the routine identification of mycobacteria and has the potential for providing identifications of mycobacterial isolates which are more accurate than conventional identification techniques based on morphologic and biochemical characteristics. PMID:8968884

  13. High-Throughput Direct Fecal PCR Assay for Detection of Mycobacterium avium subsp. paratuberculosis in Sheep and Cattle

    PubMed Central

    Waldron, Anna M.; Galea, Francesca; Whittington, Ann-Michele; Saunders, Vanessa F.; Begg, Douglas J.; de Silva, Kumudika; Purdie, Auriol C.; Whittington, Richard J.

    2014-01-01

    Johne's disease (JD) is a chronic enteric disease caused by Mycobacterium avium subsp. paratuberculosis that affects ruminants. Transmission occurs by the fecal-oral route. A commonly used antemortem diagnostic test for the detection of M. avium subsp. paratuberculosis in feces is liquid culture; however, a major constraint is the 2- to 3-month incubation period needed for this method. Rapid methods for the detection of M. avium subsp. paratuberculosis based on PCR have been reported, but comprehensive validation data are lacking. We describe here a new test, the high-throughput-Johnes (HT-J), to detect M. avium subsp. paratuberculosis in feces. Its diagnostic accuracy was compared with that of liquid radiometric (Bactec) fecal culture using samples from cattle (1,330 samples from 23 herds) and sheep (596 samples from 16 flocks). The multistage protocol involves the recovery of M. avium subsp. paratuberculosis cells from a fecal suspension, cell rupture by bead beating, extraction of DNA using magnetic beads, and IS900 quantitative PCR. The limit of detection of the assay was 0.0005 pg, and the limit of quantification was 0.005 pg M. avium subsp. paratuberculosis genomic DNA. Only M. avium subsp. paratuberculosis was detected from a panel of 51 mycobacterial isolates, including 10 with IS900-like sequences. Of the 549 culture-negative fecal samples from unexposed herds and flocks, 99% were negative in the HT-J test, while 60% of the bovine- and 84% of the ovine-culture-positive samples were positive in the HT-J test. As similar total numbers of samples from M. avium subsp. paratuberculosis-exposed animals were positive in culture and HT-J tests in both species, and as the results of a McNemar's test were not significant, these methods probably have similar sensitivities, but the true diagnostic sensitivities of these tests are unknown. These validation data meet the consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis and the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines (S. A. Bustin et al., Clin. Chem. 55:611–622, 2009, doi:10.1373/clinchem.2008.112797). The HT-J assay has been approved for use in JD control programs in Australia and New Zealand. PMID:24352996

  14. Isoniazid and rifampicin heteroresistant Mycobacterium tuberculosis isolated from tuberculous meningitis patients in India.

    PubMed

    Gupta, Renu; Thakur, Rajeev; Kushwaha, Suman; Jalan, Nupur; Rawat, Pumanshi; Gupta, Piyush; Aggarwal, Amitesh; Gupta, Meena; Manchanda, Vikas

    2018-01-01

    Heteroresistant Mycobacterium tuberculosis (mixture of susceptible and resistant subpopulations) is thought to be a preliminary stage to full resistance and timely detection, initiation of correct treatment is vital for successful anti tubercular therapy. The aim of this study was to detect multi drug resistant (MDR) and heteroresistant M. tuberculosis with the associated gene mutations from patients of tuberculous meningitis. A total of 197 M. tuberculosis isolates from 478 patients of TBM were isolated from July 2012 to July 2015 and subjected to drug susceptibility testing (DST) by BACTEC MGIT and Genotype MTBDR line probe assay (LPA). Heteroresistance was defined as presence of both WT and mutant genes in LPA. Of 197 M. tuberculosis isolates, 11 (5.6%) were MDR, 23 (11.6%), 1 (0.5%) were mono resistant to isoniazid (INH) and rifampicin (RMP) respectively. Heteroresistance was detected in 8 (4%), 2 (1%) isolates to INH and RMP respectively. INH heteroresistant strains had WT bands with mutation band S315T1 whereas RMP heteroresistant strains had WT bands with mutation band S531L. The prevalence of MDR M. tuberculosis was 5.6% in TBM patients with the most common mutation being ΔWT band with S315T1 for INH and ΔWT band with S531T for RMP. MGIT DST was found to be more sensitive for detecting overall resistance in M. tuberculosis but inclusion of LPA not only reduced time for early initiation of appropriate treatment but also enabled detection of heteroresistance in 8 (4%), 2 (1%) isolates for INH and RMP respectively. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  15. Prevalence of bloodstream pathogens is higher in neonatal encephalopathy cases vs. controls using a novel panel of real-time PCR assays.

    PubMed

    Tann, Cally J; Nkurunziza, Peter; Nakakeeto, Margaret; Oweka, James; Kurinczuk, Jennifer J; Were, Jackson; Nyombi, Natasha; Hughes, Peter; Willey, Barbara A; Elliott, Alison M; Robertson, Nicola J; Klein, Nigel; Harris, Kathryn A

    2014-01-01

    In neonatal encephalopathy (NE), infectious co-morbidity is difficult to diagnose accurately, but may increase the vulnerability of the developing brain to hypoxia-ischemia. We developed a novel panel of species-specific real-time PCR assays to identify bloodstream pathogens amongst newborns with and without NE in Uganda. Multiplex real-time PCR assays for important neonatal bloodstream pathogens (gram positive and gram negative bacteria, cytomegalovirus (CMV), herpes simplex virus(HSV) and P. falciparum) were performed on whole blood taken from 202 encephalopathic and 101 control infants. Automated blood culture (BACTEC) was performed for all cases and unwell controls. Prevalence of pathogenic bacterial species amongst infants with NE was 3.6%, 6.9% and 8.9%, with culture, PCR and both tests in combination, respectively. More encephalopathic infants than controls had pathogenic bacterial species detected (8.9%vs2.0%, p = 0.028) using culture and PCR in combination. PCR detected bacteremia in 11 culture negative encephalopathic infants (3 Group B Streptococcus, 1 Group A Streptococcus, 1 Staphylococcus aureus and 6 Enterobacteriacae). Coagulase negative staphylococcus, frequently detected by PCR amongst case and control infants, was considered a contaminant. Prevalence of CMV, HSV and malaria amongst cases was low (1.5%, 0.5% and 0.5%, respectively). This real-time PCR panel detected more bacteremia than culture alone and provides a novel tool for detection of neonatal bloodstream pathogens that may be applied across a range of clinical situations and settings. Significantly more encephalopathic infants than controls had pathogenic bacterial species detected suggesting that infection may be an important risk factor for NE in this setting.

  16. Efficacy of various pasteurization time-temperature conditions in combination with homogenization on inactivation of Mycobacterium avium subsp. paratuberculosis in milk.

    PubMed

    Grant, Irene R; Williams, Alan G; Rowe, Michael T; Muir, D Donald

    2005-06-01

    The effect of various pasteurization time-temperature conditions with and without homogenization on the viability of Mycobacterium avium subsp. paratuberculosis was investigated using a pilot-scale commercial high-temperature, short-time (HTST) pasteurizer and raw milk spiked with 10(1) to 10(5) M. avium subsp. paratuberculosis cells/ml. Viable M. avium subsp. paratuberculosis was cultured from 27 (3.3%) of 816 pasteurized milk samples overall, 5 on Herrold's egg yolk medium and 22 by BACTEC culture. Therefore, in 96.7% of samples, M. avium subsp. paratuberculosis had been completely inactivated by HTST pasteurization, alone or in combination with homogenization. Heat treatments incorporating homogenization at 2,500 lb/in2, applied upstream (as a separate process) or in hold (at the start of a holding section), resulted in significantly fewer culture-positive samples than pasteurization treatments without homogenization (P < 0.001 for those in hold and P < 0.05 for those upstream). Where colony counts were obtained, the number of surviving M. avium subsp. paratuberculosis cells was estimated to be 10 to 20 CFU/150 ml, and the reduction in numbers achieved by HTST pasteurization with or without homogenization was estimated to be 4.0 to 5.2 log10. The impact of homogenization on clump size distribution in M. avium subsp. paratuberculosis broth suspensions was subsequently assessed using a Mastersizer X spectrometer. These experiments demonstrated that large clumps of M. avium subsp. paratuberculosis cells were reduced to single-cell or "miniclump" status by homogenization at 2,500 lb/in2. Consequently, when HTST pasteurization was being applied to homogenized milk, the M. avium subsp. paratuberculosis cells would have been present as predominantly declumped cells, which may possibly explain the greater inactivation achieved by the combination of pasteurization and homogenization.

  17. Efficacy of Various Pasteurization Time-Temperature Conditions in Combination with Homogenization on Inactivation of Mycobacterium avium subsp. paratuberculosis in Milk

    PubMed Central

    Grant, Irene R.; Williams, Alan G.; Rowe, Michael T.; Muir, D. Donald

    2005-01-01

    The effect of various pasteurization time-temperature conditions with and without homogenization on the viability of Mycobacterium avium subsp. paratuberculosis was investigated using a pilot-scale commercial high-temperature, short-time (HTST) pasteurizer and raw milk spiked with 101 to 105 M. avium subsp. paratuberculosis cells/ml. Viable M. avium subsp. paratuberculosis was cultured from 27 (3.3%) of 816 pasteurized milk samples overall, 5 on Herrold's egg yolk medium and 22 by BACTEC culture. Therefore, in 96.7% of samples, M. avium subsp. paratuberculosis had been completely inactivated by HTST pasteurization, alone or in combination with homogenization. Heat treatments incorporating homogenization at 2,500 lb/in2, applied upstream (as a separate process) or in hold (at the start of a holding section), resulted in significantly fewer culture-positive samples than pasteurization treatments without homogenization (P < 0.001 for those in hold and P < 0.05 for those upstream). Where colony counts were obtained, the number of surviving M. avium subsp. paratuberculosis cells was estimated to be 10 to 20 CFU/150 ml, and the reduction in numbers achieved by HTST pasteurization with or without homogenization was estimated to be 4.0 to 5.2 log10. The impact of homogenization on clump size distribution in M. avium subsp. paratuberculosis broth suspensions was subsequently assessed using a Mastersizer X spectrometer. These experiments demonstrated that large clumps of M. avium subsp. paratuberculosis cells were reduced to single-cell or “miniclump” status by homogenization at 2,500 lb/in2. Consequently, when HTST pasteurization was being applied to homogenized milk, the M. avium subsp. paratuberculosis cells would have been present as predominantly declumped cells, which may possibly explain the greater inactivation achieved by the combination of pasteurization and homogenization. PMID:15932977

  18. Effect of Turbulent-Flow Pasteurization on Survival of Mycobacterium avium subsp. paratuberculosis Added to Raw Milk

    PubMed Central

    Pearce, Lindsay E.; Truong, H. Tuan; Crawford, Robert A.; Yates, Gary F.; Cavaignac, Sonia; de Lisle, Geoffrey W.

    2001-01-01

    A pilot-scale pasteurizer operating under validated turbulent flow (Reynolds number, 11,050) was used to study the heat sensitivity of Mycobacterium avium subsp. paratuberculosis added to raw milk. The ATCC 19698 type strain, ATCC 43015 (Linda, human isolate), and three bovine isolates were heated in raw whole milk for 15 s at 63, 66, 69, and 72°C in duplicate trials. No strains survived at 72°C for 15 s; and only one strain survived at 69°C. Means of pooled D values (decimal reduction times) at 63 and 66°C were 15.0 ± 2.8 s (95% confidence interval) and 5.9 ± 0.7 s (95% confidence interval), respectively. The mean extrapolated D72°C was <2.03 s. This was equivalent to a >7 log10 kill at 72°C for 15 s (95% confidence interval). The mean Z value (degrees required for the decimal reduction time to traverse one log cycle) was 8.6°C. These five strains showed similar survival whether recovery was on Herrold's egg yolk medium containing mycobactin or by a radiometric culture method (BACTEC). Milk was inoculated with fresh fecal material from a high-level fecal shedder with clinical Johne's disease. After heating at 72°C for 15 s, the minimum M. avium subsp. paratuberculosis kill was >4 log10. Properly maintained and operated equipment should ensure the absence of viable M. avium subsp. paratuberculosis in retail milk and other pasteurized dairy products. An additional safeguard is the widespread commercial practice of pasteurizing 1.5 to 2° above 72°C. PMID:11525992

  19. Gaps in capacity for respiratory care in developing countries. Nigeria as a case study.

    PubMed

    Obaseki, Daniel; Adeniyi, Bamidele; Kolawole, Tolulope; Onyedum, Cajetan; Erhabor, Gregory

    2015-04-01

    There are unmet needs for respiratory medical care in developing countries. We sought to evaluate the quality and capacity for respiratory care in low- and lower-middle-income countries, using Nigeria as a case study. We obtained details of the respiratory practice of consultants and senior residents (fellows) in respiratory medicine in Nigeria via a semistructured questionnaire administered to physician attendees at the 2013 National Congress of the Nigerian Thoracic Society. Out of 76 society-registered members, 48 attended the congress, 40 completed the questionnaire, and 35 provided complete data (73% adjusted response rate). Respondents provided information on the process and costs of respiratory medicine training and facility, equipment, and supply capacities at the institutions they represented. Approximately 83% reported working at a tertiary level (teaching) hospital; 91% reported capacity for sputum smear analysis for acid alcohol-fast bacilli, 37% for GeneXpert test cartridges, and 20% for BACTEC liquid sputum culture. Only 34% of respondents could perform full spirometry on patients, and none had the capacity for performing a methacholine challenge test or for measuring the diffusion capacity for carbon monoxide. We estimated the proportion of registered respiratory physicians to the national population at 1 per 2.3 million individuals. Thirteen states with an estimated combined population of 57.7 million offer no specialist respiratory services. Barriers to development of this capacity include the high cost of training. We conclude that substantial gaps exist in the capacity and quality of respiratory care in Nigeria, a pattern that probably mirrors most of sub-Saharan Africa and other countries of similar economic status. Health policy makers should address these gaps systematically.

  20. Effect of milk fermentation by kefir grains and selected single strains of lactic acid bacteria on the survival of Mycobacterium bovis BCG.

    PubMed

    Macuamule, C L S; Wiid, I J; van Helden, P D; Tanner, M; Witthuhn, R C

    2016-01-18

    Mycobacterium bovis that causes Bovine tuberculosis (BTB) can be transmitted to humans thought consumption of raw and raw fermented milk products from diseased animals. Lactic acid bacteria (LAB) used in popular traditional milk products in Africa produce anti-microbial compounds that inhibit some pathogenic and spoilage bacteria. M. bovis BCG is an attenuated non-pathogenic vaccine strain of M. bovis and the aim of the study was to determine the effect of the fermentation process on the survival of M. bovis BCG in milk. M. bovis BCG at concentrations of 6 log CFU/ml was added to products of kefir fermentation. The survival of M. bovis BCG was monitored at 12-h intervals for 72 h by enumerating viable cells on Middlebrook 7H10 agar plates enriched with 2% BD BACTEC PANTA™. M. bovis BCG was increasingly reduced in sterile kefir that was fermented for a period of 24h and longer. In the milk fermented with kefir grains, Lactobacillus paracasei subsp. paracasei or Lactobacillus casei, the viability of M. bovis BCG was reduced by 0.4 logs after 24h and by 2 logs after 48 h of fermentation. No viable M. bovis BCG was detected after 60 h of fermentation. Results from this study show that long term fermentation under certain conditions may have the potential to inactivate M. bovis BCG present in the milk. However, to ensure safety of fermented milk in Africa, fermentation should be combined with other hurdle technologies such as boiling and milk pasteurisation. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. [Candida and Aspergillus infections in the light of a new list of alarm factors on the example of the Lodz Medical University Hospital No. 1].

    PubMed

    Tyczkowska-Sieroń, Ewa; Bartoszko-Tyczkowska, Anna

    2012-01-01

    In 2011, the Polish Ministry of Health introduced Candida sp. resistant to fluconazole and Aspergillus sp. to the list of Alarm Factors as alert pathogens. The purpose of this paper is to confirm the validity of continuous monitoring of fungal infections caused by the pathogens mentioned above. The role offluconazole therapy in the Candida sp. infections is also discussed. The analysis of the fungal infections is performed based on the results obtained in the University Clinic Hospital (UCH) No. 1 in Lodz in 2009-2011. The swabs were plated on Sabouraud's agar. Body fluids and blood were incubated in an automated system Bactec 9050. Yeast ID Phoenix BD panels were used to determine the species of fungi. In turn, antimicrobial susceptibility testing was carried out by E-tests (bioMerieux). In the analysis of fungal infections occurring among patients in the UCH No. 1 in Lodz in 2009-2011, C. albicans, C. non-albicans and Aspergillus sp. infections are taken into account. This analysis is performed based on relations of the number of infections (per 100 patients) versus six-month periods. As one can see in Fig. 1, a clear, linear and statistically significant increase in the number of C. albicans and C. non-albicans infections is observed throughout the entire time period under discussion. On the other hand, the number of Aspergillus sp. infections remains at an almost constant low level. The more detailed analysis of fungal infections in the different hospital units, which are particularly exposed to this type of infections (Figs. 2-6), shows that there is a clear correlation between the number of C. non-albicans infections and the frequency of therapy with fluconazole. The results presented in this paper show in the example of the UCH No. 1 in Lodz that the number of infections caused by C. albicans and C. non-albicans resistant to fluconazole is clearly increasing in a hospital environment in recent years, which is a great clinical problem. Although the number of Aspergillus sp. infections is relatively much lower in comparison to that of Candidia sp., these infections also constitute a problem of clinical importance. In light of the presented analysis, it should be assessed positively the fact that Candida sp. resistant to fluconazole and Aspergillus sp. are considered to be alert pathogens that require the continuous monitoring.

  2. Bacteriophage-based assays for the rapid detection of rifampicin resistance in Mycobacterium tuberculosis: a meta-analysis.

    PubMed

    Pai, Madhukar; Kalantri, Shriprakash; Pascopella, Lisa; Riley, Lee W; Reingold, Arthur L

    2005-10-01

    To summarize, using meta-analysis, the accuracy of bacteriophage-based assays for the detection of rifampicin resistance in Mycobacterium tuberculosis. By searching multiple databases and sources we identified a total of 21 studies eligible for meta-analysis. Of these, 14 studies used phage amplification assays (including eight studies on the commercial FASTPlaque-TB kits), and seven used luciferase reporter phage (LRP) assays. Sensitivity, specificity, and agreement between phage assay and reference standard (e.g. agar proportion method or BACTEC 460) results were the main outcomes of interest. When performed on culture isolates (N=19 studies), phage assays appear to have relatively high sensitivity and specificity. Eleven of 19 (58%) studies reported sensitivity and specificity estimates > or =95%, and 13 of 19 (68%) studies reported > or =95% agreement with reference standard results. Specificity estimates were slightly lower and more variable than sensitivity; 5 of 19 (26%) studies reported specificity <90%. Only two studies performed phage assays directly on sputum specimens; although one study reported sensitivity and specificity of 100 and 99%, respectively, another reported sensitivity of 86% and specificity of 73%. Current evidence is largely restricted to the use of phage assays for the detection of rifampicin resistance in culture isolates. When used on culture isolates, these assays appear to have high sensitivity, but variable and slightly lower specificity. In contrast, evidence is lacking on the accuracy of these assays when they are directly applied to sputum specimens. If phage-based assays can be directly used on clinical specimens and if they are shown to have high accuracy, they have the potential to improve the diagnosis of MDR-TB. However, before phage assays can be successfully used in routine practice, several concerns have to be addressed, including unexplained false positives in some studies, potential for contamination and indeterminate results.

  3. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a containment level-III laboratory as part of a Laboratory Risk Assessment Program.

    PubMed

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-24

    In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures.

  4. Inactivation of Mycobacterium paratuberculosis in cows' milk at pasteurization temperatures.

    PubMed Central

    Grant, I R; Ball, H J; Neill, S D; Rowe, M T

    1996-01-01

    The thermal inactivation of 11 strains of Mycobacterium paratuberculosis at pasteurization temperatures was investigated. Cows' milk inoculated with M. paratuberculosis at two levels (10(7) and 10(4) CFU/ml) was pasteurized in the laboratory by (i) a standard holder method (63.5 degrees C for 30 min) and (ii) a high-temperature, short-time (HTST) method (71.7 degrees C for 15 s). Additional heating times of 5, 10, 15, 20, and 40 min at 63.5 degrees C were included to enable the construction of a thermal death curve for the organism. Viability after pasteurization was assessed by culture on Herrold's egg yolk medium containing mycobactin J (HEYM) and in BACTEC Middlebrook 12B radiometric medium supplemented with mycobactin J and sterile egg yolk emulsion. Confirmation of acid-fast survivors of pasteurization as viable M. paratuberculosis cells was achieved by subculture on HEYM to indicate viability coupled with PCR using M. paratuberculosis-specific 1S900 primers. When milk was initially inoculated with 10(6) to 10(7) CFU of M. paratuberculosis per ml, M. paratuberculosis cells were isolated from 27 of 28 (96%) and 29 of 34 (85%) pasteurized milk samples heat treated by the holder and HTST methods, respectively. Correspondingly, when 10(3) to 10(4) CFU of M. paratuberculosis per ml of milk were present before heat treatment, M. paratuberculosis cells were isolated from 14 of 28 (50%) and 19 of 33 (58%) pasteurized milk samples heat treated by the holder and HTST methods, respectively. The thermal death curve for M. paratuberculosis was concave in shape, exhibiting a rapid initial death rate followed by significant "tailing." Results indicate that when large numbers of M. paratuberculosis cells are present in milk, the organism may not be completely inactivated by heat treatments simulating holder and HTST pasteurization under laboratory conditions. PMID:8593064

  5. Effect of Three Factors in Cheese Production (pH, Salt, and Heat) on Mycobacterium avium subsp. paratuberculosis Viability

    PubMed Central

    Sung, Nackmoon; Collins, Michael T.

    2000-01-01

    Low pH and salt are two factors contributing to the inactivation of bacterial pathogens during a 60-day curing period for cheese. The kinetics of inactivation for Mycobacterium avium subsp. paratuberculosis strains ATCC 19698 and Dominic were measured at 20°C under different pH and NaCl conditions commonly used in processing cheese. The corresponding D values (decimal reduction times; the time required to kill 1 log10 concentration of bacteria) were measured. Also measured were the D values for heat-treated and nonheated M. avium subsp. paratuberculosis in 50 mM acetate buffer (pH 5.0, 2% [wt/vol] NaCl) and a soft white Hispanic-style cheese (pH 6.0, 2% [wt/vol] NaCl). Samples were removed at various intervals until no viable cells were detected using the radiometric culture method (BACTEC) for enumeration of M. avium subsp. paratuberculosis. NaCl had little or no effect on the inactivation of M. avium subsp. paratuberculosis, and increasing NaCl concentrations were not associated with decreasing D values (faster killing) in the acetate buffer. Lower pHs, however, were significantly correlated with decreasing D values of M. avium subsp. paratuberculosis in the acetate buffer. The D values for heat-treated M. avium subsp. paratuberculosis ATCC 19698 in the cheese were higher than those predicted by studies done in acetate buffer. The heat-treated M. avium subsp. paratuberculosis strains had lower D values than the nonheated cells (faster killing) both in the acetate buffer (pH 5, 2% [wt/vol] NaCl) and in the soft white cheese. The D value for heat-treated M. avium subsp. paratuberculosis ATCC 19698 in the cheese (36.5 days) suggests that heat treatment of raw milk coupled with a 60-day curing period will inactivate about 103 cells of M. avium subsp. paratuberculosis per ml. PMID:10742208

  6. Culture Phenotypes of Genomically and Geographically Diverse Mycobacterium avium subsp. paratuberculosis Isolates from Different Hosts▿

    PubMed Central

    Whittington, Richard J.; Marsh, Ian B.; Saunders, Vanessa; Grant, Irene R.; Juste, Ramon; Sevilla, Iker A.; Manning, Elizabeth J. B.; Whitlock, Robert H.

    2011-01-01

    Mycobacterium avium subsp. paratuberculosis causes paratuberculosis (Johne's disease) in ruminants in most countries. Historical data suggest substantial differences in culturability of M. avium subsp. paratuberculosis isolates from small ruminants and cattle; however, a systematic comparison of culture media and isolates from different countries and hosts has not been undertaken. Here, 35 field isolates from the United States, Spain, Northern Ireland, and Australia were propagated in Bactec 12B medium and Middlebrook 7H10 agar, genomically characterized, and subcultured to Lowenstein-Jensen (LJ), Herrold's egg yolk (HEY), modified Middlebrook 7H10, Middlebrook 7H11, and Watson-Reid (WR) agars, all with and without mycobactin J and some with sodium pyruvate. Fourteen genotypes of M. avium subsp. paratuberculosis were represented as determined by BstEII IS900 and IS1311 restriction fragment length polymorphism analysis. There was no correlation between genotype and overall culturability, although most S strains tended to grow poorly on HEY agar. Pyruvate was inhibitory to some isolates. All strains grew on modified Middlebrook 7H10 agar but more slowly and less prolifically on LJ agar. Mycobactin J was required for growth on all media except 7H11 agar, but growth was improved by the addition of mycobactin J to 7H11 agar. WR agar supported the growth of few isolates. The differences in growth of M. avium subsp. paratuberculosis that have historically been reported in diverse settings have been strongly influenced by the type of culture medium used. When an optimal culture medium, such as modified Middlebrook 7H10 agar, is used, very little difference between the growth phenotypes of diverse strains of M. avium subsp. paratuberculosis was observed. This optimal medium is recommended to remove bias in the isolation and cultivation of M. avium subsp. paratuberculosis. PMID:21430104

  7. Phenotypic Characterization of pncA Mutants of Mycobacterium tuberculosis

    PubMed Central

    Morlock, Glenn P.; Crawford, Jack T.; Butler, W. Ray; Brim, Suzanne E.; Sikes, David; Mazurek, Gerald H.; Woodley, Charles L.; Cooksey, Robert C.

    2000-01-01

    We examined the correlation of mutations in the pyrazinamidase (PZase) gene (pncA) with the pyrazinamide (PZA) resistance phenotype with 60 Mycobacterium tuberculosis isolates. PZase activity was determined by the method of Wayne (L. G. Wayne, Am. Rev. Respir. Dis. 109:147–151, 1974), and the entire pncA nucleotide sequence, including the 74 bp upstream of the start codon, was determined. PZA susceptibility testing was performed by the method of proportions on modified Middlebrook and Cohn 7H10 medium. The PZA MICs were ≥100 μg/ml for 37 isolates, 34 of which had alterations in the pncA gene. These mutations included missense substitutions for 24 isolates, nonsense substitutions for 3 isolates, frameshifts by deletion for 4 isolates, a three-codon insertion for 1 isolate, and putative regulatory mutations for 2 isolates. Among 21 isolates for which PZA MICs were <100 μg/ml, 3 had the same mutation (Thr47→Ala) and 18 had the wild-type sequence. For the three Thr47→Ala mutants PZA MICs were 12.5 μg/ml by the method of proportions on 7H10 agar; two of these were resistant to 100 μg of PZA per ml and the third was resistant to 800 μg of PZA per ml by the BACTEC method. In all, 30 different pncA mutations were found among the 37 pncA mutants. No PZase activity was detected in 35 of 37 strains that were resistant to ≥100 μg of PZA per ml or in 34 of 37 pncA mutants. Reduced PZase activity was found in the three mutants with the Thr47→Ala mutation. This study demonstrates that mutations in the pncA gene may serve as a reliable indicator of resistance to ≥100 μg of PZA per ml. PMID:10952570

  8. [An unusual cause of febrile neutropenia: brucellosis].

    PubMed

    Solmaz, Soner; Asma, Süheyl; Ozdoğu, Hakan; Yeral, Mahmut; Turunç, Tuba

    2014-10-01

    Febrile neutropenia which is a common complication of cancer treatment, is one of the major causes of morbidity and mortality. Several gram-negative and gram-positive bacteria are responsible for infections in neutropenic patients, however the most common microorganisms are Escherichia coli and coagulase-negative staphylococci, in decreasing order. Although Brucella spp. infections are endemic in Turkey, brucellosis-related febrile neutropenia has only rarely been reported. In this report, a case of brucellosis-related febrile neutropenia in a patient with acute myeloblastic leukemia (AML) was presented. A 56-year-old male patient presenting with fever, petechiae/purpura, leukocytosis, thrombocytopenia, and anemia was admitted to our hospital. Laboratory studies revealed a hemoglobin level of 8.27 g/dl, leukocyte count of 77.100 k/ml, absolute neutrophil count of 200 k/ml, and platelets at 94.200 k/ml. The patient was diagnosed as AML-M1 and piperacillin/tazobactam was started as the first-line antibiotic therapy due to the febrile neutropenia. On admission, blood and urine cultures were negative. Once the fever was controlled, remission/induction chemotherapy was initiated. However, fever developed again on the eight day, and vancomycin was added to the therapy. Since the fever persisted, the antibiotic therapy was gradually replaced with meropenem and linezolid. However, fever continued and the patient's general condition deteriorated. Subsequently performed Brucella tube agglutination test revealed positivity at 1/320 titer and the microorganism grown in blood culture (Bactec 9050; BD, USA) was identified as B.melitensis by conventional methods. Rifampicin and doxycycline therapy was started immediately, however, the patient died due to septic shock. If the tests for brucellosis were performed earlier when response to second step antibiotic therapy lacked in this patient, it was assumed that mortality could be prevented by the prompt initiation of the appropriate treatment. Thus, since brucellosis is endemic in Turkey, it should be considered as a possible agent of febrile neutropenia especially in patients unresponsive to empiric antibiotherapy and appropriate diagnostic tests should be performed.

  9. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment Level-III Laboratory as part of a Laboratory Risk Assessment Program

    PubMed Central

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-01

    Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation) may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in house biosafety-validated practices with the aim of protecting laboratory workers conducting these procedures. PMID:15667662

  10. Genetic diversity, transmission dynamics, and drug resistance of Mycobacterium tuberculosis in Luanda, Angola.

    PubMed

    Perdigão, João; Clemente, Sofia; Ramos, Jorge; Masakidi, Pedro; Machado, Diana; Silva, Carla; Couto, Isabel; Viveiros, Miguel; Taveira, Nuno; Portugal, Isabel

    2016-12-01

    Despite the important role that the African region plays in a global tuberculosis (TB) epidemiological context, many countries in the region still lack data on the prevalence of specific Mycobacterium tuberculosis strains and drug resistance. This is the case for Angola, which presently lacks any data concerning drug-resistance rates and prevalence of specific M. tuberculosis genotypes and respective population structure. In this study, we made the first characterization of the genetic diversity and drug resistance of M. tuberculosis complex strains circulating in Luanda, Angola's most important setting concerning TB epidemiology. We have analyzed 89 M. tuberculosis isolates recovered from the same number of patients. All clinical isolates were genotyped by spoligotyping and 24-loci mycobacterial interspersed repetitive unit-variable number of tandem repeats (MIRU-VNTRs). First-line drug-susceptibility testing was performed by the standard BACTEC 960 Mycobacteria Growth Indicator Tube (MGIT) procedure. We have detected 33 different spoligotype profiles corresponding to 24 different shared international types (SITs) and nine orphan profiles. SIT 20 (LAM1) was the most prevalent (n=16, 18.2%) followed by SIT 42 (LAM9; n=15, 17.1%). Overall, the M. tuberculosis population structure in this sample was dominated by LAM (64.8%) and T (33.0%) strains. Twenty-four-loci MIRU-VNTR analysis revealed that a total of 13 isolates were grouped into five distinct clusters. Drug-susceptibility testing revealed a worrying situation concerning resistance rates. Drug-susceptibility data showed that 22 (24.7%) of the 89 clinical isolates were resistant to one or more antibacillary drugs of which four (4.5%) were multidrug resistant (MDR). Drug-resistant isolates were found across distinct clades and MIRU-VNTR clusters. This first cross-sectional study conducted in Luanda, Angola, provides a framework for future studies and programmatic management of TB in Angola. We provide sufficient evidence for cluster-based transmission with a high predominance of LAM strains, with differential geographic dispersion. The moderate rate of MDR-TB found in this sample has major public health implications and highlights the need for further studies specifically focused on MDR-TB transmission. Copyright © 2016.

  11. Baseline predictors of sputum culture conversion in pulmonary tuberculosis: importance of cavities, smoking, time to detection and W-Beijing genotype.

    PubMed

    Visser, Marianne E; Stead, Michael C; Walzl, Gerhard; Warren, Rob; Schomaker, Michael; Grewal, Harleen M S; Swart, Elizabeth C; Maartens, Gary

    2012-01-01

    Time to detection (TTD) on automated liquid mycobacterial cultures is an emerging biomarker of tuberculosis outcomes. The M. tuberculosis W-Beijing genotype is spreading globally, indicating a selective advantage. There is a paucity of data on the association between baseline TTD and W-Beijing genotype and tuberculosis outcomes. To assess baseline predictors of failure of sputum culture conversion, within the first 2 months of antitubercular therapy, in participants with pulmonary tuberculosis. Between May 2005 and August 2008 we conducted a prospective cohort study of time to sputum culture conversion in ambulatory participants with first episodes of smear and culture positive pulmonary tuberculosis attending two primary care clinics in Cape Town, South Africa. Rifampicin resistance (diagnosed on phenotypic susceptibility testing) was an exclusion criterion. Sputum was collected weekly for 8 weeks for mycobacterial culture on liquid media (BACTEC MGIT 960). Due to missing data, multiple imputation was performed. Time to sputum culture conversion was analysed using a Cox-proportional hazards model. Bayesian model averaging determined the posterior effect probability for each variable. 113 participants were enrolled (30.1% female, 10.5% HIV-infected, 44.2% W-Beijing genotype, and 89% cavities). On Kaplan Meier analysis 50.4% of participants underwent sputum culture conversion by 8 weeks. The following baseline factors were associated with slower sputum culture conversion: TTD (adjusted hazard ratio (aHR) = 1.11, 95% CI 1.02; 1.2), lung cavities (aHR = 0.13, 95% CI 0.02; 0.95), ever smoking (aHR = 0.32, 95% CI 0.1; 1.02) and the W-Beijing genotype (aHR = 0.51, 95% CI 0.25; 1.07). On Bayesian model averaging, posterior probability effects were strong for TTD, lung cavitation and smoking and moderate for W-Beijing genotype. We found that baseline TTD, smoking, cavities and W-Beijing genotype were associated with delayed 2 month sputum culture. Larger studies are needed to confirm the relationship between the W-Beijing genotype and sputum culture conversion.

  12. NMR-based metabonomics for understanding the influence of dormant female genital tuberculosis on metabolism of the human endometrium.

    PubMed

    Subramani, E; Jothiramajayam, M; Dutta, M; Chakravorty, D; Joshi, M; Srivastava, S; Mukherjee, A; Datta Ray, C; Chakravarty, B N; Chaudhury, K

    2016-04-01

    Does investigation of metabolic perturbations in endometrial tissue of women with dormant genital tuberculosis (GTB) during the window of implantation (WOI) assist in improving the understanding of endometrial receptivity? In dormant GTB cases significant alterations in endometrial tissue metabolites occur, largely related to energy metabolism and amino acid biosynthesis in dormant GTB cases. As an intracellular pathogen, Mycobacterium tuberculosis strongly influences the metabolism of host cells causing metabolic dysregulation. It is also accepted that dormant GTB impairs the receptive status of the endometrium. Global metabolic profiling is useful for an understanding of disease progression and distinguishing between diseased and non-diseased groups. Endometrial tissue samples were collected from patients reporting at the tertiary infertility care center during the period September 2011-March 2013. Women having tested positive for GTB were considered as the study group (n = 24). Normal healthy women undergoing sterilization (n = 26) and unexplained infertile women with repeated IVF failure (n = 21) volunteered to participate as controls. Endometrial tissue samples were collected 6-10 days after confirmation of ovulation. PCR and BACTEC-460 culture were used for diagnosing GTB. Proton nuclear magnetic resonance (1H NMR) spectra of tissue were recorded using a 700 MHz Bruker Avance AV III spectrometer. Following phase and baseline correction of all NMR spectra by Bruker Topspin 2.1 software, spectral peak alignment of the data was performed. Multivariate analysis was applied to all spectra and individual metabolites identified and multiple correlation analysis was performed. Leucine, isoleucine, acetate, lactate, glutamate, glutamine, methionine, lysine, creatine, glycogen, glycine, proline and choline were found to be significantly increased (P < 0.05) in endometrial tissue of women with dormant GTB compared with unexplained infertile women with repeated implantation failure. Valine, citrate, succinate and aspartate were also observed to be significantly up-regulated (P < 0.01). Furthermore, a significant decrease in glucose (P < 0.05), threonine (P < 0.05), tyrosine (P < 0.01) and phenylalanine (P < 0.0001) was observed in women with dormant GTB. Pearson's correlation analysis between the expression of various endometrial receptivity markers and metabolites showed a significant negative correlation (-0.236 to -0.545, P < 0.05). Also, the metabolites were positively correlated with endometrial receptivity markers (0.207 to 0.618, P < 0.05). It is often difficult to diagnose dormant GTB because it tends to exist without any clinical signs or symptoms. In addition, the diagnosis of GTB by culture remains a challenge due to low detection rates and its paucibacillary nature. Testing for prostate-specific antigen or the Y chromosome in order to account for the possible influences of recent exposure to semen on endometrial metabolism would be important. The metabolic changes associated with the dormant tubercle infection are of potential relevance to clinicians for the treatment of dormant GTB-related infertility. Government of India, Indian Council of Medical Research. There are no conflicts of interest. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Genetic diversity and distribution of Mycobacterium tuberculosis genotypes in Limpopo, South Africa.

    PubMed

    Maguga-Phasha, N T C; Munyai, N S; Mashinya, F; Makgatho, M E; Mbajiorgu, E F

    2017-12-12

    Tuberculosis remains a major health problem and knowledge of the diversity of Mycobacterium tuberculosis strains in specific geographical regions can contribute to the control of the disease. This study describes the genetic profile of M. tuberculosis in five districts of Limpopo Province. A total 487 isolates were collected from the National Health Laboratory Services from all regions/districts of Limpopo Province. Only 215 isolates were confirmed to be M. tuberculosis by Bactec Mycobacterium Growth Indicator Tube 960® and Rhodamine-Auramine staining. Isolates were subcultured on Löwenstein-Jensen medium agar slants to validate purity. They were spoligotyped and data analysed using the international spoligotyping database 4 (SpolDB4). Of the 215 isolates, 134 (62.3%) were genotyped into 21 genotype families while 81 (37.7%) were orphans. The 81 orphans were further subjected to resolution employing SpolDB3/RIM. Overall, the study revealed a high diversity of strains of 32 predominantly the non-Beijing lineages: the LAM- LAM3 (9.8%), LAM9 (4.7%) and LAM11- ZWE (3.3%), the T-T1(15.0%), T2 (0.9%), T2-T3 (1.4%), the CAS-CAS1-Delhi 5 (1.9%) and CAS1-KILI (1.4%) the MANU2 (1.4%), U (0.5%), X-X1(1.4%), X3 (1.9%), S (9.8%), CAS (1.4%), LAM7(0.9%), T3(0.5%), LAM8(4.7%), T4(1.4%), X2(0.4%), AI5(1.9%), LAM1(0.5%), FAMILY33 (1.9%), EAI4(1.4%), M. microti (1.9%). The Beijing and Beijing-like families were (14.9%) and (0.9%), respectively. A total of 28(13%) clusters and 77(36%) unique cases were identified. Beijing strain (SIT 1) formed the biggest cluster constituting 14%, followed by LAM3 (SIT 33), T1 (SIT 53) and LAM4 (SIT 811) with 7%, 5.1% and 2.8%, respectively. The Beijing family was the only genotype found in all the five districts and was predominant in Mopani (18.8%), Sekhukhune (23.7%) and Vhembe (23.3%). Dominant genotypes in Capricorn and Waterberg were LAM3 (11.9%) and T1 (13.3%), respectively. A wide diversity of lineages was demonstrated at district level. A high number of clusters per district provided evidence of on-going transmission in this Province.

  14. Evaluation of genotype MTBDRplus VER 2.0 line probe assay for the detection of MDR-TB in smear positive and negative sputum samples.

    PubMed

    Meaza, Abyot; Kebede, Abebaw; Yaregal, Zelalem; Dagne, Zekarias; Moga, Shewki; Yenew, Bazezew; Diriba, Getu; Molalign, Helina; Tadesse, Mengistu; Adisse, Desalegn; Getahun, Muluwork; Desta, Kassu

    2017-04-17

    Multi drug resistant tuberculosis (MDR-TB) poses formidable challenges to TB control due to its complex diagnostic and treatment challenges and often associated with a high rate of mortality. Accurate and rapid detection of MDR-TB is critical for timely initiation of treatment. Line Probe Assay (LPA) is a qualitative in vitro diagnostic test based on DNA-STRIP technology for the identification of the M. tuberculosis complex and its resistance to rifampicin (RMP) and/or isoniazid (INH). Hain Lifescience, GmbH, Germany has improved the sensitivity of Genotype MTBDRplus VER 2.0 LPA for the detection of MDR-TB; with the possibility of applying the tool in smear negative sputum samples. A cross sectional study was conducted on 274 presumptive MDR-TB patients referred to the National TB Reference Laboratory (NTRL), Ethiopian Public Health Institute (EPHI) who submitted sputum samples for laboratory diagnosis of drug resistant-TB testing. Seventy-two smear and culture positive samples processed in smear positive direct LPA category and 197 smear negative sputum samples were processed for direct LPA. Among the smear negative samples 145 (73.6%) were culture negative and 26 (13.2%) were culture positive. All specimens were processed using NALC-NaOH method and ZN smear microscopy done from sediments. Genotype MTBDRplus VER 2.0 done from processed sputum sediments and the result was compared against the reference, BACTEC MGIT 960 culture and DST. Sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 assay was determined and P-value <0.05 was considered as statistically significant. The sensitivity, specificity, PPV and NPV of Genotype MTBDRplus VER 2.0 LPA were 96.4, 100, 100 and 96.9%, respectively for the detection of MDR-TB from direct smear positive sputum samples. The sensitivity, specificity, PPV and NPV of Genotype MTBDR plus VER 2.0 LPA were 77.8, 97.2, 82.4 and 97.2%, respectively, for the detection of M. tuberculosis from direct smear negative sputum samples. Fourteen (53.8%) samples had valid results with LPA among the 26 smear negative culture positive samples. The remaining 8 (30.8%) and 4 (15.4%) were invalid and negative with LPA, respectively. The sensitivity and specificity of Genotype MTBDRplus VER 2.0 LPA were 100% for the detection of MDR-TB among 14 direct smear negative and culture positive sputum samples. The most common mutations associated with RMP and INH resistance were S531L and S315TL, respectively. A single rare mutation (C15T/A16G) was detected for INH resistance. The diagnostic performance of Genotype MTBDRplus VER 2.0 LPA in direct smear positive sputum sample was highly sensitive and specific for early detection of MDR-TB. However, the diagnostic performance of this molecular assay in direct smear negative sputum sample was low and showed a high level of invalid results for detection of M. tuberculosis and its resistance to RMP and/or INH so it is unlikely to implement Genotype MTBDRplus VER 2.0 for the detection of MDR-TB in direct smear negative sample in our routine settings. The sensitivity of the assay should be improved for detection of MDR-TB in direct smear negative sputum specimens.

  15. Comparative Economics Systems in the Undergraduate Curriculum: An Update

    ERIC Educational Resources Information Center

    Kovzik, Alexander; Johnson, Marianne

    2016-01-01

    In this study, the authors report on the status of comparative economics systems in the U.S. undergraduate economics curriculum. The treatment of comparative economics systems topics in introductory courses is examined through a survey of standard textbooks. To evaluate comparative economics systems at the advanced undergraduate level, they rely…

  16. Comparative health systems research among Kaiser Permanente and other integrated delivery systems: a systematic literature review.

    PubMed

    Maeda, Jared Lane K; Lee, Karen M; Horberg, Michael

    2014-01-01

    Because of rising health care costs, wide variations in quality, and increased patient complexity, the US health care system is undergoing rapid changes that include payment reform and movement toward integrated delivery systems. Well-established integrated delivery systems, such as Kaiser Permanente (KP), should work to identify the specific system-level factors that result in superior patient outcomes in response to policymakers' concerns. Comparative health systems research can provide insights into which particular aspects of the integrated delivery system result in improved care delivery. To provide a baseline understanding of comparative health systems research related to integrated delivery systems and KP. Systematic literature review. We conducted a literature search on PubMed and the KP Publications Library. Studies that compared KP as a system or organization with other health care systems or across KP facilities internally were included. The literature search identified 1605 articles, of which 65 met the study inclusion criteria and were examined by 3 reviewers. Most comparative health systems studies focused on intra-KP comparisons (n = 42). Fewer studies compared KP with other US (n = 15) or international (n = 12) health care systems. Several themes emerged from the literature as possible factors that may contribute to improved care delivery in integrated delivery systems. Of all studies published by or about KP, only a small proportion of articles (4%) was identified as being comparative health systems research. Additional empirical studies that compare the specific factors of the integrated delivery system model with other systems of care are needed to better understand the "system-level" factors that result in improved and/or diminished care delivery.

  17. COMPARE : a method for analyzing investment alternatives in industrial wood and bark energy systems

    Treesearch

    Peter J. Ince

    1983-01-01

    COMPARE is a FORTRAN computer program resulting from a study to develop methods for comparative economic analysis of alternatives in industrial wood and bark energy systems. COMPARE provides complete guidelines for economic analysis of wood and bark energy systems. As such, COMPARE can be useful to those who have only basic familiarity with investment analysis of wood...

  18. [Comparative analysis of Andean and Caribbean region health systems].

    PubMed

    Gómez-Camelo, Diana

    2005-01-01

    Carrying out a comparative analysis of Andean and Caribbean health systems contributing towards the general panorama of Andean and Caribbean region health care system experience. This study was aimed at carrying out a comparative analysis of health systems in Bolivia, Colombia, Ecuador, Peru, Venezuela, the Dominican Republic and Cuba between 1990 and 2004. Documentary information from secondary sources was used. Reform and changes during the aforementioned period were compared, as well as the systems' current configurations. Described typologies were used for studying the health systems. Different organisational designs were found for the systems: a national health system (NHS), segmented systems and systems based on mandatory insurance. The trend of reforms introduced in the 1990s and current proposals in almost all systems are directed towards adopting mandatory insurance via a basic packet of services and strengthening competition in providing services through a public and private mix. The organisation and structure of most systems studied have introduced and continue to introduce changes in line with international guidelines. The generality of these structures means that efforts must still be made to adopt designs strengthening them as instruments improving populations' quality of life. Comparative analysis is a tool leading to studying health systems and producing information which can nourish debate regarding current sector reform. This work took shape during the first approach to a comparative study of Andean region and Caribbean health systems.

  19. Comparison of plateletpheresis on the Fenwal Amicus, Fresenius COM.TEC, and Trima Accel Cell separators.

    PubMed

    Keklik, Muzaffer; Eser, Bulent; Kaynar, Leylagul; Sivgin, Serdar; Keklik, Ertugrul; Solmaz, Musa; Ozturk, Ahmet; Buyukoglan, Ruksan; Yay, Mehmet; Cetin, Mustafa; Unal, Ali

    2015-06-01

    Blood component donations by apheresis have become more common in modern blood transfusion practices. We compared three apheresis instruments (Fenwal Amicus, Fresenius COM.TEC, and Trima Accel) with regard to platelet (PLT) yield, collection efficiency (CE), and collection rate (CR). The single-needle or double-needle plateletpheresis procedures of the three instruments were compared in a retrospective, randomized study in 270 donors. The blood volume processed was higher in the COM.TEC compared with the Amicus and Trima. Also there was a significantly higher median volume of ACD used in collections on the COM.TEC compared with the Amicus and Trima. The PLT yield was significantly lower with the COM.TEC compared with the Amicus and Trima. Additionally, the CE was significantly lower with the COM.TEC compared with the Amicus and Trima. There was no significant difference in median separation time and CR between the three groups. When procedures were compared regarding CE by using Amicus device, it was significantly higher in single-needle than double-needle plateletpheresis. When double-needle Amicus system was compared with double-needle COM.TEC system, CE and PLT yield were significantly higher with Amicus system. When single-needle Amicus system was compared with single-needle Trima system, CE and PLT yield were significantly higher with Trima system. All instruments collected PLTs efficiently. However, the CE was lower with the COM.TEC compared with the Amicus and Trima. Also, we found Amicus single-needle system collected PLTs more efficiently compared with the double-needle system. CE and PLT yields were significantly higher with the single-needle Trima instrument compared with the single-needle Amicus device. © 2014 Wiley Periodicals, Inc.

  20. Advantages and Disadvantages of the National Security Personnel System as Compared to the General Schedule Personnel System

    DTIC Science & Technology

    2005-12-01

    NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA JOINT APPLIED PROJECT Advantages and Disadvantages of the National Security...Applied Project 4. TITLE AND SUBTITLE: Advantages and Disadvantages of the National Security Personnel System as Compared to the General...compare and contrast the advantages and disadvantages of the new personnel system (NSPS) versus the General Schedule (GS) personnel system currently

  1. A Comparative Study of Pre-Service Education for Preschool Teachers in China and the United States

    ERIC Educational Resources Information Center

    Gong, Xin; Wang, Pengcheng

    2017-01-01

    This study provides a comparative analysis of the pre-service education system for preschool educators in China and the United States. Based on collected data and materials (literature, policy documents, and statistical data), we compare two areas of pre-service training: (1) the formal system; (2) the informal system. In the formal system, most…

  2. Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

    NASA Astrophysics Data System (ADS)

    Wijaya Sunu, Putu; Made Rasta, I.; Anakottapary, Daud Simon; Made Suarta, I.; Cipta Santosa, I. D. M.

    2018-01-01

    The aims of this study to compares the performance characteristics of a water chiller air conditioning simulation equipped with thermostatic expansion valve (TEV) with those of a capillary tube. Water chiller system filled with the same charge of refrigerant. Comparative analyses were performed based on coefficient of performance (COP) and performance parameter of the refrigeration system, carried out at medium cooling load level with the ambient temperature of 29-31°C, constant compressor speed and fixed chilled water volume flowrate at 15 lpm. It was shown that the TEV system showed better energy consumption compared to that of capillary tube. From the coefficient of performance perspective, the thermostatic expansion valve system showed higher COP (± 21.4%) compared to that of capillary tube system.

  3. Comparing systems for costing hospital treatments. The case of stable angina pectoris.

    PubMed

    Larsen, Jytte; Skjoldborg, Ulla Slothuus

    2004-03-01

    This paper demonstrates the basic properties in the systems most commonly considered for costing treatments in the Danish hospitals. The differences between the traditional charge system, the DRG system and the ABC system are analysed, and difficulties encountered in comparing these systems are discussed. A sample of patients diagnosed with stable angina pectoris (SAP) at Odense University Hospital was used to compare the three systems when costing an entire treatment path, costing single hospitalisations and studying the effects of length of stay. Furthermore, it is illustrated that the main idea behind each system is reflected in how the systems over- or underestimate costs. Implications when managing the hospitals, particularly reimbursement, are discussed.

  4. Communication linguistique: Etude comparative faite sur le terrain (Linguistic Communication: A Comparative Field Study).

    ERIC Educational Resources Information Center

    Piron, Claude

    2002-01-01

    Compares the four international systems of linguistic communication used in the field (systems used in the United Nations, multinationals, the European Union, and Esperanto organizations) on select criteria (e.g., previous government investment). Discusses research that shows unilingual systems (English used alone, Esperanto) are those that…

  5. Impact of Organic and Conventional Systems of Coffee Farming on Soil Properties and Culturable Microbial Diversity

    PubMed Central

    2016-01-01

    A study was undertaken with an objective of evaluating the long-term impacts of organic (ORG) and conventional (CON) methods of coffee farming on soil physical, chemical, biological, and microbial diversity. Electrical conductivity and bulk density were found to increase by 34% and 21%, respectively, in CON compared to ORG system, while water holding capacity was found decreased in both the systems. Significant increase in organic carbon was observed in ORG system. Major nutrients, nitrogen and potassium, levels showed inclination in both ORG and CON system, but the trend was much more pronounced in CON system. Phosphorus was found to increase in both ORG and CON system, but its availability was found to be more with CON system. In biological attributes, higher soil respiration and fluorescein diacetate activity were recorded in ORG system compared to CON system. Higher soil urease activity was observed in CON system, while dehydrogenase activity does not show significant differences between ORG and CON systems. ORG system was found to have higher macrofauna (31.4%), microbial population (34%), and microbial diversity indices compared to CON system. From the present study, it is accomplished that coffee soil under long-term ORG system has better soil properties compared to CON system. PMID:27042378

  6. Impact of Organic and Conventional Systems of Coffee Farming on Soil Properties and Culturable Microbial Diversity.

    PubMed

    Velmourougane, Kulandaivelu

    2016-01-01

    A study was undertaken with an objective of evaluating the long-term impacts of organic (ORG) and conventional (CON) methods of coffee farming on soil physical, chemical, biological, and microbial diversity. Electrical conductivity and bulk density were found to increase by 34% and 21%, respectively, in CON compared to ORG system, while water holding capacity was found decreased in both the systems. Significant increase in organic carbon was observed in ORG system. Major nutrients, nitrogen and potassium, levels showed inclination in both ORG and CON system, but the trend was much more pronounced in CON system. Phosphorus was found to increase in both ORG and CON system, but its availability was found to be more with CON system. In biological attributes, higher soil respiration and fluorescein diacetate activity were recorded in ORG system compared to CON system. Higher soil urease activity was observed in CON system, while dehydrogenase activity does not show significant differences between ORG and CON systems. ORG system was found to have higher macrofauna (31.4%), microbial population (34%), and microbial diversity indices compared to CON system. From the present study, it is accomplished that coffee soil under long-term ORG system has better soil properties compared to CON system.

  7. W-026, Waste Receiving and Processing Facility data management system validation and verification report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palmer, M.E.

    1997-12-05

    This V and V Report includes analysis of two revisions of the DMS [data management system] System Requirements Specification (SRS) and the Preliminary System Design Document (PSDD); the source code for the DMS Communication Module (DMSCOM) messages; the source code for selected DMS Screens, and the code for the BWAS Simulator. BDM Federal analysts used a series of matrices to: compare the requirements in the System Requirements Specification (SRS) to the specifications found in the System Design Document (SDD), to ensure the design supports the business functions, compare the discreet parts of the SDD with each other, to ensure thatmore » the design is consistent and cohesive, compare the source code of the DMS Communication Module with the specifications, to ensure that the resultant messages will support the design, compare the source code of selected screens to the specifications to ensure that resultant system screens will support the design, compare the source code of the BWAS simulator with the requirements to interface with DMS messages and data transfers relating to the BWAS operations.« less

  8. Information/Knowledge Acquisition Methods for Decision Support Systems and Expert Systems.

    ERIC Educational Resources Information Center

    Yang, Heng-Li

    1995-01-01

    Compares information requirement-elicitation (IRE) methods for decision support systems (DSS) with knowledge acquisition (KA) methods for expert systems (ES) development. The definition and architectures of ES and DSS are compared and the systems' development cycles and IRE/KA methods are discussed. Differences are noted between ES and DSS…

  9. Application of a reversible chemical reaction system to solar thermal power plants

    NASA Technical Reports Server (NTRS)

    Hanseth, E. J.; Won, Y. S.; Seibowitz, L. P.

    1980-01-01

    Three distributed dish solar thermal power systems using various applications of SO2/SO3 chemical energy storage and transport technology were comparatively assessed. Each system features various roles for the chemical system: (1) energy storage only, (2) energy transport, or (3) energy transport and storage. These three systems were also compared with the dish-Stirling, using electrical transport and battery storage, and the central receiver Rankine system, with thermal storage, to determine the relative merit of plants employing a thermochemical system. As an assessment criterion, the busbar energy costs were compared. Separate but comparable solar energy cost computer codes were used for distributed receiver and central receiver systems. Calculations were performed for capacity factors ranging from 0.4 to 0.8. The results indicate that SO2/SO3 technology has the potential to be more cost effective in transporting the collected energy than in storing the energy for the storage capacity range studied (2-15 hours)

  10. Analysis of GaAs and Si solar energy hybrid systems

    NASA Technical Reports Server (NTRS)

    Heinbockel, J. H.; Roberts, A. S., Jr.

    1977-01-01

    Various silicon hybrid systems are modeled and compared with a gallium arsenide hybrid system. The hybrid systems modeled produce electric power and also thermal power which can be used for heating or air conditioning. Various performance indices are defined and used to compare the system performance: capital cost per electric power out; capital cost per total power out; capital cost per electric power plus mechanical power; annual cost per annual electric energy; and annual cost per annual electric energy plus annual mechanical work. These performance indices indicate that concentrator hybrid systems can be cost effective when compared with present day energy costs.

  11. Case Studies Comparing System Advisor Model (SAM) Results to Real Performance Data: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blair, N.; Dobos, A.; Sather, N.

    2012-06-01

    NREL has completed a series of detailed case studies comparing the simulations of the System Advisor Model (SAM) and measured performance data or published performance expectations. These case studies compare PV measured performance data with simulated performance data using appropriate weather data. The measured data sets were primarily taken from NREL onsite PV systems and weather monitoring stations.

  12. An Analytic Comparison of Educational Systems: Overview of Purposes, Policies, Structures and Outcomes. Comparative Overview/Comparative Assessment.

    ERIC Educational Resources Information Center

    Hurn, Christopher J.; Burn, Barbara B.

    This comparative evaluation of the differing educational systems in North America, Europe, the USSR, and Japan examines the goals and values of these systems. It is pointed out that Americans value equality, practicality, and utility and that they are both individualistic and suspicious of government authority. Contrasts between these values and…

  13. Life cycle assessment of a commercial rainwater harvesting system compared with a municipal water supply system

    EPA Science Inventory

    Building upon previously published life cycle assessment (LCA) methodologies, we conducted an LCA of a commercial rainwater harvesting (RWH) system and compared it to a municipal water supply (MWS) system adapted to Washington, D.C. Eleven life cycle impact assessment (LCIA) indi...

  14. Lessons from Elsewhere?: Comparative Music Education in Times of Globalization

    ERIC Educational Resources Information Center

    Kertz-Welzel, Alexandra

    2015-01-01

    In recent years, comparative education and comparative music education became important fields of research. Due to globalization, but also to international student assessments, it is most common to compare the outcomes of entire school systems or specific subject areas. The main goal is to identify the most successful systems and their best…

  15. Development and comparison of user acceptance of advanced comprehensive triage PDA support system with a traditional terminal alternative system.

    PubMed

    Chang, Polun; Tzeng, Yuann-Meei; Wu, Shiao-Chi; Sang, Ying-Yang; Chen, Shih-Shin

    2003-01-01

    An advanced PDA support system for the triage was designed to evaluate users inverted exclamation mark | acceptance of this system compared with a traditional terminal system. Davis inverted exclamation mark | Technology Acceptance Model was used to evaluate users inverted exclamation mark | acceptance. All 72 ER nurses in a 2700-bed medical center were invited for the study. The results showed that the PDA system was easier to operate than the terminal one, but had worse interface. The subjects showed significantly greater willingness to accept the terminal system instead of the PDA system. The comparative acceptance of PDA, compared with that of the old system, might still be marginally too low if its interface couldn inverted exclamation mark |t be improved or no other unique practical benefits could be verified.

  16. CO2 Supermarket Refrigeration Systems for Southeast Asia and the USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Vishaldeep; Fricke, Brian A; Bansal, Pradeep

    This paper presents a comparative analysis of the annual energy consumption of these refrigeration systems in eighty eight cities from all climate zones in Southeast Asia. Also, the performance of the CO2 refrigeration systems is compared to the baseline R404A multiplex direct expansion (DX) system. Finally, the overall performance of the CO2 refrigeration systems in various climatic conditions in Southeast Asia is compared to that in the United States. For the refrigeration systems investigated, it was found that the Transcritical Booster System with Bypass Compressor (TBS-BC) performs better or equivalent to the R404A multiplex DX system in the northern regionsmore » of Southeast Asia (China and Japan). In the southern regions of Southeast Asia (India, Bangladesh, Burma), the R404A multiplex DX system and the Combined Secondary Cascade (CSC) system performs better than the TBS-BC.« less

  17. Comparative effectiveness of the SNaP™ Wound Care System.

    PubMed

    Hutton, David W; Sheehan, Peter

    2011-04-01

    Diabetic lower extremity wounds cause substantial burden to healthcare systems, costing tens of thousands of dollars per episode. Negative pressure wound therapy (NPWT) devices have been shown to be cost-effective at treating these wounds, but the traditional devices use bulky electrical pumps that require a durable medical equipment rental-based procurement process. The Spiracur SNaP™ Wound Care System is an ultraportable NPWT system that does not use an electric pump and is fully disposable. It has superior healing compared to standard of care with modern dressings and comparable healing to traditional NPWT devices while giving patients greater mobility and giving clinicians a simpler procurement process. We used a mathematical model to analyse the costs of the SNaP™ system and compare them to standard of care and electrically powered NPWT devices. When compared to standard of care, the SNaP™ system saves over $9000 per wound treated and more than doubles the number of patients healed. The SNaP system has similar healing time to powered NPWT devices, but saves $2300 in Medicare payments or $2800 for private payers per wound treated. Our analysis shows that the SNaP™ system could save substantial treatment costs in addition to allowing patients greater freedom and mobility. © 2011 The Authors. © 2011 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  18. Comparison of fuel-cell and diesel integrated energy systems and a conventional system for a 500-unit apartment

    NASA Technical Reports Server (NTRS)

    Simons, S. N.; Maag, W. L.

    1978-01-01

    The electrical and thermal energy utilization efficiencies of a 500 unit apartment complex are analyzed and compared for each of three energy supply systems. Two on-site integrated energy systems, one powered by diesel engines and the other by phosphoric-acid fuel cells were compared with a conventional system which uses purchased electricity and on-site boilers for heating. All fuels consumed on-site are clean, synthetic fuels (distillate fuel oil or pipeline quality gas) derived from coal. Purchased electricity was generated from coal at a central station utility. The relative energy consumption and economics of the three systems are analyzed and compared.

  19. Cancer risk in women using the levonorgestrel-releasing intrauterine system in Finland.

    PubMed

    Soini, Tuuli; Hurskainen, Ritva; Grénman, Seija; Mäenpää, Johanna; Paavonen, Jorma; Pukkala, Eero

    2014-08-01

    To examine the association between premenopausal use of the levonorgestrel-releasing intrauterine system and cancer incidence in Finland with a special focus on endometrial adenocarcinoma. All Finnish women aged 30-49 years using a levonorgestrel-releasing intrauterine system for treatment of menorrhagia in 1994-2007 (n=93,843) were identified from the National Reimbursement Registry and linked to the Finnish Cancer Registry data. The incidence of cancers in levonorgestrel-releasing intrauterine system users was compared with that in the general population. A total of 2,781 cancer cases were detected in levonorgestrel-releasing intrauterine system users during the follow-up of 855,324 women-years. The standardized incidence ratio (observed-to-expected ratio) for endometrial adenocarcinoma was 0.50 (95% confidence interval [CI] 0.35-0.70; 34 observed compared with 68 expected cases) after the first levonorgestrel-releasing intrauterine system purchase and 0.25 (95% CI 0.05-0.73; three observed compared with 12 expected cases) after two purchases. The standardized incidence ratio for ovarian cancer was 0.60 (95% CI 0.45-0.76; 59 observed compared with 99 expected cases), for pancreatic cancer 0.50 (95% CI 0.28-0.81; 15 observed compared with 30 expected cases), and for lung cancer 0.68 (95% CI 0.49-0.91; 43 observed compared with 63 expected cases). The standardized incidence ratio for breast cancer among all levonorgestrel-releasing intrauterine system users was 1.19 (95% CI 1.13-1.25; 1,542 observed compared with 1,292 expected cases). The levonorgestrel-releasing intrauterine system may have a protective effect against endometrial malignant transformation. Using the levonorgestrel-releasing intrauterine system for treatment of menorrhagia during reproductive years was associated with a lower incidence of endometrial, ovarian, pancreatic, and lung cancers than expected. Levonorgestrel-releasing intrauterine system use was associated with a higher than expected incidence of breast cancer. II.

  20. Noise Exposure in TKA Surgery; Oscillating Tip Saw Systems vs Oscillating Blade Saw Systems.

    PubMed

    Peters, Michiel P; Feczko, Peter Z; Tsang, Karel; van Rietbergen, Bert; Arts, Jacobus J; Emans, Peter J

    2016-12-01

    Historically it has been suggested that noise-induced hearing loss (NIHL) affects approximately 50% of the orthopedic surgery personnel. This noise may be partially caused by the use of powered saw systems that are used to make the bone cuts. The first goal was to quantify and compare the noise emission of these different saw systems during total knee arthroplasty (TKA) surgery. A second goal was to estimate the occupational NIHL risk for the orthopedic surgery personnel in TKA surgery by quantifying the total daily noise emission spectrum during TKA surgery and to compare this to the Dutch Occupational Health Organization guidelines. A conventional sagittal oscillating blade system with a full oscillating blade and 2 newer oscillating tip saw systems (handpiece and blade) were compared. Noise level measurements during TKA surgery were performed during cutting and hammering, additionally surgery noise profiles were made. The noise level was significantly lower for the oscillating tip saw systems compared to the conventional saw system, but all were in a range that can cause NIHL. The conventional system handpiece produced a considerable higher noise level compared to oscillating tip handpiece. NIHL is an underestimated problem in the orthopedic surgery. Solutions for decreasing the risk of hearing loss should be considered. The use of oscillating tip saw systems have a reduced noise emission in comparison with the conventional saw system. The use of these newer systems might be a first step in decreasing hearing loss among the orthopedic surgery personnel. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A comparison of smartphones to paper-based questionnaires for routine influenza sentinel surveillance, Kenya, 2011-2012.

    PubMed

    Njuguna, Henry N; Caselton, Deborah L; Arunga, Geoffrey O; Emukule, Gideon O; Kinyanjui, Dennis K; Kalani, Rosalia M; Kinkade, Carl; Muthoka, Phillip M; Katz, Mark A; Mott, Joshua A

    2014-12-24

    For disease surveillance, manual data collection using paper-based questionnaires can be time consuming and prone to errors. We introduced smartphone data collection to replace paper-based data collection for an influenza sentinel surveillance system in four hospitals in Kenya. We compared the quality, cost and timeliness of data collection between the smartphone data collection system and the paper-based system. Since 2006, the Kenya Ministry of Health (MoH) with technical support from the Kenya Medical Research Institute/Centers for Disease Control and Prevention (KEMRI/CDC) conducted hospital-based sentinel surveillance for influenza in Kenya. In May 2011, the MOH replaced paper-based collection with an electronic data collection system using Field Adapted Survey Toolkit (FAST) on HTC Touch Pro2 smartphones at four sentinel sites. We compared 880 paper-based questionnaires dated Jan 2010-Jun 2011 and 880 smartphone questionnaires dated May 2011-Jun 2012 from the four surveillance sites. For each site, we compared the quality, cost and timeliness of each data collection system. Incomplete records were more likely seen in data collected using pen-and-paper compared to data collected using smartphones (adjusted incidence rate ratio (aIRR) 7, 95% CI: 4.4-10.3). Errors and inconsistent answers were also more likely to be seen in data collected using pen-and-paper compared to data collected using smartphones (aIRR: 25, 95% CI: 12.5-51.8). Smartphone data was uploaded into the database in a median time of 7 days while paper-based data took a median of 21 days to be entered (p < 0.01). It cost USD 1,501 (9.4%) more to establish the smartphone data collection system ($17,500) than the pen-and-paper system (USD $15,999). During two years, however, the smartphone data collection system was $3,801 (7%) less expensive to operate ($50,200) when compared to pen-and-paper system ($54,001). Compared to paper-based data collection, an electronic data collection system produced fewer incomplete data, fewer errors and inconsistent responses and delivered data faster. Although start-up costs were higher, the overall costs of establishing and running the electronic data collection system were lower compared to paper-based data collection system. Electronic data collection using smartphones has potential to improve timeliness, data integrity and reduce costs.

  2. A framework for comparative analysis of health systems: experiences from the Asia Pacific Observatory on Health Systems and Policies.

    PubMed

    Healy, Judith Mary; Tang, Shenglan; Patcharanarumol, Walaiporn; Annear, Peter Leslie

    2018-04-01

    Drawing on published work from the Asia Pacific Observatory on Health Systems and Policies, this paper presents a framework for undertaking comparative studies on the health systems of countries. Organized under seven types of research approaches, such as national case-studies using a common format, this framework is illustrated using studies of low- and middle-income countries published by the Asia Pacific Observatory. Such studies are important contributions, since much of the health systems research literature comes from high-income countries. No one research approach, however, can adequately analyse a health system, let alone produce a nuanced comparison of different countries. Multiple comparative studies offer a better understanding, as a health system is a complex entity to describe and analyse. Appreciation of context and culture is crucial: what works in one country may not do so in another. Further, a single research method, such as performance indicators, or a study of a particular health system function or component, produces only a partial picture. Applying a comparative framework of several study approaches helps to inform and explain progress against health system targets, to identify differences among countries, and to assess policies and programmes. Multi-method comparative research produces policy-relevant learning that can assist countries to achieve Sustainable Development Goal 3: ensure healthy lives and promoting well-being for all at all ages by 2030.

  3. Efficacy of two rotary retreatment systems in removing Gutta-percha and sealer during endodontic retreatment with or without solvent: A comparative in vitro study.

    PubMed

    Bhagavaldas, Moushmi Chalakkarayil; Diwan, Abhinav; Kusumvalli, S; Pasha, Shiraz; Devale, Madhuri; Chava, Deepak Chowdary

    2017-01-01

    The aim of this in vitro study was to compare the efficacy of two retreatment rotary systems in the removal of Gutta-percha (GP) and sealer from the root canal walls with or without solvent. Forty-eight extracted human mandibular first premolars were prepared and obturated with GP and AH Plus sealer. Samples were then randomly divided into four groups. Group I was retreated with MtwoR rotary system without solvent, Group II was retreated with MtwoR rotary system with Endosolv R as the solvent, Group III with D-RaCe rotary system without solvent, and Group IV with D-RaCe rotary system and Endosolv R solvent. The cleanliness of canal walls was determined by stereomicroscope (×20) and AutoCAD software. Kruskal-Wallis test and Mann-Whitney U-test were used to compare the data. Results showed that none of the retreatment systems used in this study was able to completely remove the root canal filling material. D-RaCe with or without solvent showed significantly ( P > 0.05) less filling material at all levels compared to MtwoR with/without solvent. Within the limitation of the current study, D-RaCe rotary retreatment system is more effective in removing filling material from root canal walls when compared to MtwoR rotary retreatment system.

  4. SOAR versus SQ3R: A Test of Two Study Systems

    ERIC Educational Resources Information Center

    Jairam, Dharma; Kiewra, Kenneth A.; Rogers-Kasson, Sarah; Patterson-Hazley, Melissa; Marxhausen, Kim

    2014-01-01

    Although researchers have long investigated ways to improve study habits and raise achievement, few studies compare study strategy systems with one another. No study to date has compared the long popular SQ3R (Survey, Question, Read, Recite, Review) system with the more modern SOAR (Select, Organize, Associate, Regulate) system. This study…

  5. One Language, Two Number-Word Systems and Many Problems: Numerical Cognition in the Czech Language

    ERIC Educational Resources Information Center

    Pixner, S.; Zuber, J.; Hermanova, V.; Kaufmann, L.; Nuerk, H.-C.; Moeller, K.

    2011-01-01

    Comparing numerical performance between different languages does not only mean comparing different number-word systems, but also implies a comparison of differences regarding culture or educational systems. The Czech language provides the remarkable opportunity to disentangle this confound as there exist two different number-word systems within…

  6. Comparing the Document Representations of Two IR-Systems: CLARIT and TOPIC.

    ERIC Educational Resources Information Center

    Paijmans, Hans

    1993-01-01

    Compares two information retrieval systems, CLARIT and TOPIC, in terms of assigned versus derived and precoordinate versus postcoordinate indexing. Models of information retrieval systems are discussed, and a test of the systems using a demonstration database of full-text articles from the "Wall Street Journal" is described. (Contains 21…

  7. Continuous System-Level Scale for Comparing Laser Gain Media

    DTIC Science & Technology

    2008-12-01

    thickness in Yb3+-doped microchip lasers . J. Opt. Soc. Am. B October 2003, 20, 2061–2067. 29. Liu, Q.; Gong, M.; Lu, F.; Gong, W.; Li, C. 520-W...Continuous “System-Level” Scale for Comparing Laser Gain Media by Jeffrey O. White ARL-TR-4682 December 2008...System-Level” Scale for Comparing Laser Gain Media Jeffrey O. White Sensors and Electron Devices Directorate, ARL

  8. Towards a comparative analysis of health systems reforms in the Asia-Pacific Region.

    PubMed

    Phua, Kai Hong; Chew, Amelia Huibin

    2002-01-01

    The paper will review a representative selection of health systems reforms throughout the Asia-Pacific region to summarise the regional experience, identify the key lessons learnt from innovative health reforms and propose policy recommendations for sustainable health systems development. Broad descriptive trends of health systems reforms will be compared across the Asia-Pacific region within the context of rapid demographic, health and socio-economic development. More specifically, the study will address the following questions: 1. What are the main features of innovative health systems reforms? 2. How have these reforms affected the health systems? 3. Are there lessons and other implications from these reforms? A common conceptual framework to compare health systems reforms is adopted, using a standardised format to report data of national health systems. A classification of health systems is constructed by categorising them according to the level of development of their respective economies: 1) Developed 2 )High Performing 3) Newly Industrialising 4) Transitional, and 5) Developing. A typology of common issues, challenges and responses are generalised for these health systems at different stages of socio-economic development of individual countries. Evaluative criteria are proposed to compare the long-term effects of these reforms on national health systems in terms of efficiency, equity, quality and sustainability.

  9. Healthcare Systems in Comparative Perspective: Classification, Convergence, Institutions, Inequalities, and Five Missed Turns

    PubMed Central

    Beckfield, Jason; Olafsdottir, Sigrun; Sosnaud, Benjamin

    2017-01-01

    This essay reviews and evaluates recent comparative social science scholarship on healthcare systems. We focus on four of the strongest themes in current research: (1) the development of typologies of healthcare systems, (2) assessment of convergence among healthcare systems, (3) problematization of the shifting boundaries of healthcare systems, and (4) the relationship between healthcare systems and social inequalities. Our discussion seeks to highlight the central debates that animate current scholarship and identify unresolved questions and new opportunities for research. We also identify five currents in contemporary sociology that have not been incorporated as deeply as they might into research on healthcare systems. These five “missed turns” include an emphasis on social relations, culture, postnational theory, institutions, and causal mechanisms. We conclude by highlighting some key challenges for comparative research on healthcare systems. PMID:28769148

  10. Is the Grass Always Greener? Comparing the Environmental Impact of Conventional, Natural and Grass-Fed Beef Production Systems.

    PubMed

    Capper, Judith L

    2012-04-10

    This study compared the environmental impact of conventional, natural and grass-fed beef production systems. A deterministic model based on the metabolism and nutrient requirements of the beef population was used to quantify resource inputs and waste outputs per 1.0 × 10⁸ kg of hot carcass weight beef in conventional (CON), natural (NAT) and grass-fed (GFD) production systems. Production systems were modeled using characteristic management practices, population dynamics and production data from U.S. beef production systems. Increased productivity (slaughter weight and growth rate) in the CON system reduced the cattle population size required to produce 1.0 × 10⁸ kg of beef compared to the NAT or GFD system. The CON system required 56.3% of the animals, 24.8% of the water, 55.3% of the land and 71.4% of the fossil fuel energy required to produce 1.0 × 10⁸ kg of beef compared to the GFD system. The carbon footprint per 1.0 × 10⁸ kg of beef was lowest in the CON system (15,989 × 10³ t), intermediate in the NAT system (18,772 × 10³ t) and highest in the GFD system (26,785 × 10³ t). The challenge to the U.S beef industry is to communicate differences in system environmental impacts to facilitate informed dietary choice.

  11. Systematic review with meta-analysis: rifaximin for the prophylaxis of spontaneous bacterial peritonitis.

    PubMed

    Goel, A; Rahim, U; Nguyen, L H; Stave, C; Nguyen, M H

    2017-12-01

    The primary and secondary prevention of spontaneous bacterial peritonitis (SBP) is recommended in high-risk patients with cirrhosis. Several studies evaluating the efficacy of rifaximin for SBP prophylaxis have yielded conflicting results. Rifaximin has the potential advantage of preventing bacterial overgrowth and translocation without the systemic side effects of broad-spectrum antibiotics. To evaluate the efficacy of rifaximin in the primary and secondary prevention of SBP. A literature search using five databases was performed to identify studies on the association between rifaximin and SBP. We performed two meta-analyses: (1) rifaximin compared to systemic antibiotics and (2) rifaximin compared to no antibiotics. Random-effect modelling was conducted to determine overall pooled estimates and 95% confidence intervals (CIs). Five studies with 555 patients (295 rifaximin, 260 systemic antibiotics) compared rifaximin with systemic antibiotics. The pooled odds ratio (OR) for SBP was 0.45 (95% CI 0.16-1.27; P = .13) in patients receiving rifaximin and strengthened on sensitivity analysis (OR 0.38, 95% CI 0.19-0.76, P = .01). In the analysis comparing rifaximin with no antibiotics, there were five studies with 784 patients (186 rifaximin, 598 no antibiotics). The OR for SBP was 0.34 (95% CI 0.11-0.99; P < .05) in patients receiving rifaximin. In subgroup analysis, rifaximin reduced the risk of SBP by 47% compared to no antibiotics for primary prophylaxis and by 74% compared to systemic antibiotics for secondary prophylaxis. Rifaximin may be effective in preventing SBP in patients with cirrhosis and ascites compared to systemically absorbed antibiotics and compared to placebo. © 2017 John Wiley & Sons Ltd.

  12. Large communications platforms versus smaller satellites

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Communications systems using large platforms are compared with systems using conventional satellites. Systems models were generated and compared for U.S. domestic application and for 1 INTELSAT's international and domestic transponder lease application. Technology advances were assumed the platforms and the evolution of conventional satellites.

  13. State University System Graduation and Retention Rates Are Nationally Competitive. Information Brief

    ERIC Educational Resources Information Center

    Board of Governors, State University System of Florida, 2011

    2011-01-01

    The State University System of Florida six-year graduation rate and second-year retention rate are strong compared to the ten largest public university systems. Graduation rates for the System's minority students are also competitive, with rates for non-Hispanic Black students and Hispanic students ranked in the top 10 when compared to all…

  14. Comparative Extension: The CES, TES, T&V AND FSR/D. Occasional Paper #1.

    ERIC Educational Resources Information Center

    Rivera, William M.

    Four extension systems are compared in this paper: the U.S. Cooperative Extension Service (CES), the "typical system" (TES) in developing countries, the Training and Visit System (T&V), and the Farming Systems Research and Extension (FSR/D) approach. While distinct in various ways from one another, interesting and useful insights can…

  15. Comparing two types of augmentative and alternative communication systems for children with autism.

    PubMed

    Son, Seung-Hyun; Sigafoos, Jeff; O'Reilly, Mark; Lancioni, Giulio E

    2006-01-01

    This study compared acquisition and preference for two types of augmentative and alternative communication (AAC) systems in three pre-schoolers with autism. Acquisition of requesting behaviour using a picture-exchange system vs a voice-output communication aide (VOCA) was compared in an alternating treatments design. Following acquisition, both ACC systems were simultaneously available and the child could select which one of the two systems to use. There was little difference between picture-exchange and VOCA in terms of acquisition rates. Two children demonstrated a consistent preference for picture-exchange and the third showed a preference for the VOCA. Both speed of acquisition and system preference should be considered when designing AAC interventions for children with autism and related developmental disabilities.

  16. Locating pairs of comparable study areas...new system developed

    Treesearch

    Raymond D. Ratliff; Jack N. Reppert

    1966-01-01

    A new system developed for locating pairs of comparable areas consists of three steps: (a) characterizing each of two areas according to 18 site factors and soil properties, (b) rating each pair of characteristics for comparability, and (c) rating the two areas for comparability by using the individual ratings as the basis. Two areas scoring 85 or more points out of a...

  17. CMG-biotools, a free workbench for basic comparative microbial genomics.

    PubMed

    Vesth, Tammi; Lagesen, Karin; Acar, Öncel; Ussery, David

    2013-01-01

    Today, there are more than a hundred times as many sequenced prokaryotic genomes than were present in the year 2000. The economical sequencing of genomic DNA has facilitated a whole new approach to microbial genomics. The real power of genomics is manifested through comparative genomics that can reveal strain specific characteristics, diversity within species and many other aspects. However, comparative genomics is a field not easily entered into by scientists with few computational skills. The CMG-biotools package is designed for microbiologists with limited knowledge of computational analysis and can be used to perform a number of analyses and comparisons of genomic data. The CMG-biotools system presents a stand-alone interface for comparative microbial genomics. The package is a customized operating system, based on Xubuntu 10.10, available through the open source Ubuntu project. The system can be installed on a virtual computer, allowing the user to run the system alongside any other operating system. Source codes for all programs are provided under GNU license, which makes it possible to transfer the programs to other systems if so desired. We here demonstrate the package by comparing and analyzing the diversity within the class Negativicutes, represented by 31 genomes including 10 genera. The analyses include 16S rRNA phylogeny, basic DNA and codon statistics, proteome comparisons using BLAST and graphical analyses of DNA structures. This paper shows the strength and diverse use of the CMG-biotools system. The system can be installed on a vide range of host operating systems and utilizes as much of the host computer as desired. It allows the user to compare multiple genomes, from various sources using standardized data formats and intuitive visualizations of results. The examples presented here clearly shows that users with limited computational experience can perform complicated analysis without much training.

  18. Comparing health system performance assessment and management approaches in the Netherlands and Ontario, Canada

    PubMed Central

    Tawfik-Shukor, Ali R; Klazinga, Niek S; Arah, Onyebuchi A

    2007-01-01

    Background Given the proliferation and the growing complexity of performance measurement initiatives in many health systems, the Netherlands and Ontario, Canada expressed interests in cross-national comparisons in an effort to promote knowledge transfer and best practise. To support this cross-national learning, a study was undertaken to compare health system performance approaches in The Netherlands with Ontario, Canada. Methods We explored the performance assessment framework and system of each constituency, the embeddedness of performance data in management and policy processes, and the interrelationships between the frameworks. Methods used included analysing governmental strategic planning and policy documents, literature and internet searches, comparative descriptive tables, and schematics. Data collection and analysis took place in Ontario and The Netherlands. A workshop to validate and discuss the findings was conducted in Toronto, adding important insights to the study. Results Both Ontario and The Netherlands conceive health system performance within supportive frameworks. However they differ in their assessment approaches. Ontario's Scorecard links performance measurement with strategy, aimed at health system integration. The Dutch Health Care Performance Report (Zorgbalans) does not explicitly link performance with strategy, and focuses on the technical quality of healthcare by measuring dimensions of quality, access, and cost against healthcare needs. A backbone 'five diamond' framework maps both frameworks and articulates the interrelations and overlap between their goals, themes, dimensions and indicators. The workshop yielded more contextual insights and further validated the comparative values of each constituency's performance assessment system. Conclusion To compare the health system performance approaches between The Netherlands and Ontario, Canada, several important conceptual and contextual issues must be addressed, before even attempting any future content comparisons and benchmarking. Such issues would lend relevant interpretational credibility to international comparative assessments of the two health systems. PMID:17319947

  19. Mechanical code comparator

    DOEpatents

    Peter, Frank J.; Dalton, Larry J.; Plummer, David W.

    2002-01-01

    A new class of mechanical code comparators is described which have broad potential for application in safety, surety, and security applications. These devices can be implemented as micro-scale electromechanical systems that isolate a secure or otherwise controlled device until an access code is entered. This access code is converted into a series of mechanical inputs to the mechanical code comparator, which compares the access code to a pre-input combination, entered previously into the mechanical code comparator by an operator at the system security control point. These devices provide extremely high levels of robust security. Being totally mechanical in operation, an access control system properly based on such devices cannot be circumvented by software attack alone.

  20. Secondary electric power generation with minimum engine bleed

    NASA Technical Reports Server (NTRS)

    Tagge, G. E.

    1983-01-01

    Secondary electric power generation with minimum engine bleed is discussed. Present and future jet engine systems are compared. The role of auxiliary power units is evaluated. Details of secondary electric power generation systems with and without auxiliary power units are given. Advanced bleed systems are compared with minimum bleed systems. A cost model of ownership is given. The difference in the cost of ownership between a minimum bleed system and an advanced bleed system is given.

  1. Comparative Study of Vocational Education and Training Systems: National Vocational Education and Training Systems across Three Regions under Pressure of Change. Review of Research.

    ERIC Educational Resources Information Center

    Keating, J.; Medrich, E.; Volkoff, V.; Perry, J.

    A study to compare vocational education and training (VET) systems examined nine countries across these three large geographical regions: Europe, East Asia, and the Americas. It explored variables that most define and influence characteristics, behavior, and apparent success of VET systems and the impact of change. The nine systems were chosen on…

  2. Lesson Plan on Comparative Political Systems: Compare and Contrast the Presidential Election System of the USA to the Parliamentary Election System of Hungary.

    ERIC Educational Resources Information Center

    O'Connell, Daniel W.

    This lesson describes the current government of Hungary and its underlying political and electoral systems. The lesson is structured with: (1) background on the parliamentary model of government, political parties, and Hungary's unique electoral system; (2) a summary of the six major political parties in Hungary and voter information for the 1990…

  3. Chinese Educational Development in Comparative Perspective.

    ERIC Educational Resources Information Center

    King, Edmund

    1984-01-01

    Chinese history is outlined, modern developments briefly described and compared to events in Japan, and the development of the formal education system covered. Universalized educational opportunity and hierarchies in the school system are discussed as well as the school system in general and teacher education programs. (MH)

  4. A comparative interregional analysis of selected data from LANDSAT-1 and EREP for the inventory and monitoring of natural ecosystems

    NASA Technical Reports Server (NTRS)

    Poulton, C. E.

    1975-01-01

    Comparative statistics were presented on the capability of LANDSAT-1 and three of the Skylab remote sensing systems (S-190A, S-190B, S-192) for the recognition and inventory of analogous natural vegetations and landscape features important in resource allocation and management. Two analogous regions presenting vegetational zonation from salt desert to alpine conditions above the timberline were observed, emphasizing the visual interpretation mode in the investigation. An hierarchical legend system was used as the basic classification of all land surface features. Comparative tests were run on image identifiability with the different sensor systems, and mapping and interpretation tests were made both in monocular and stereo interpretation with all systems except the S-192. Significant advantage was found in the use of stereo from space when image analysis is by visual or visual-machine-aided interactive systems. Some cost factors in mapping from space are identified. The various image types are compared and an operational system is postulated.

  5. Efficacy of two rotary retreatment systems in removing Gutta-percha and sealer during endodontic retreatment with or without solvent: A comparative in vitro study

    PubMed Central

    Bhagavaldas, Moushmi Chalakkarayil; Diwan, Abhinav; Kusumvalli, S.; Pasha, Shiraz; Devale, Madhuri; Chava, Deepak Chowdary

    2017-01-01

    Objectives: The aim of this in vitro study was to compare the efficacy of two retreatment rotary systems in the removal of Gutta-percha (GP) and sealer from the root canal walls with or without solvent. Materials and Methods: Forty-eight extracted human mandibular first premolars were prepared and obturated with GP and AH Plus sealer. Samples were then randomly divided into four groups. Group I was retreated with MtwoR rotary system without solvent, Group II was retreated with MtwoR rotary system with Endosolv R as the solvent, Group III with D-RaCe rotary system without solvent, and Group IV with D-RaCe rotary system and Endosolv R solvent. The cleanliness of canal walls was determined by stereomicroscope (×20) and AutoCAD software. Kruskal–Wallis test and Mann–Whitney U-test were used to compare the data. Results: Results showed that none of the retreatment systems used in this study was able to completely remove the root canal filling material. D-RaCe with or without solvent showed significantly (P > 0.05) less filling material at all levels compared to MtwoR with/without solvent. Conclusion: Within the limitation of the current study, D-RaCe rotary retreatment system is more effective in removing filling material from root canal walls when compared to MtwoR rotary retreatment system. PMID:28761246

  6. Comparison of manual steering and steering via joystick of a flexible rhino endoscope.

    PubMed

    Eckl, R; Gumprecht, J J; Strauss, G; Hofer, M; Dietz, A; Lueth, T C

    2010-01-01

    Flexible endoscopes are used in ENT surgery for examination tasks in cases wherever rigid endoscopes are unsuitable to reach certain positions in the nasal cavity. Until today they are steered by hand and no robotized system has been put into clinical practice. One qualification a robot manipulator system has to fulfill to be accepted is not to create new disadvantages compared to the conventional method in surgery. An important factor is the time needed to steer the new system compared to the time needed to steer the conventional system. In this article a robot manipulator system and an experiment are presented to compare the particular times test persons need to perform a certain task. This approach offers the possibility to benchmark the developed robot manipulator system and future systems for flexible rhino endoscopes.

  7. Comparative study of FDMA, TDMA and hybrid 30/20 GHz satellite communications systems for small users

    NASA Technical Reports Server (NTRS)

    Berk, G.; Jean, P. N.; Rotholz, E.

    1982-01-01

    This study compares several satellite uplink and downlink accessing schemes for a Customer Premises Service. Four conceptual system designs are presented: Satellite-Routed FDMA, Frequency-Routed TDMA, Satellite-Switched TDMA, and Processor-Routed TDMA, operating in the 30/20 GHz band. The designs are compared on the basis of estimated satellite weight, power consumption, and cost. The system capacities are analyzed for a fixed multibeam coverage of CONUS. Analysis shows that the system capacity is limited by the available satellite resources and by the terminal size and cost.

  8. Laser System Reliability

    DTIC Science & Technology

    1977-03-01

    system acquisition cycle since they provide necessary inputs to comparative analyses, cost/benefit trade -offs, and system simulations. In addition, the...Management Program from above performs the function of analyzing the system trade -offs with respect to reliability to determine a reliability goal...one encounters the problem of comparing present dollars with future dollars. In this analysis, we are trading off costs expended initially (or at

  9. 12 CFR 630.20 - Contents of the annual report to investors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...

  10. 12 CFR 630.20 - Contents of the annual report to investors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...

  11. 12 CFR 630.20 - Contents of the annual report to investors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...

  12. 12 CFR 630.20 - Contents of the annual report to investors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...

  13. 12 CFR 630.20 - Contents of the annual report to investors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... data. At a minimum, furnish the following combined financial data of the System in comparative columnar... results of operations of System institutions, on a combined basis, for the comparative years required by...) Describe, on a comparative basis, changes in the major components of net interest income. Include a...

  14. SOME PROBLEMS OF EDUCATIONAL ORGANIZATION IN COMPARATIVE PERSPECTIVE.

    ERIC Educational Resources Information Center

    HILLS, JEAN

    A COMPARATIVE ANALYSIS OF EDUCATIONAL ORGANIZATION WAS MADE WITHIN A THEORETICAL FRAMEWORK INVOLVING SOCIAL SYSTEM TERMS. ATTENTION WAS FOCUSED ON DIFFERENCES AMONG ORGANIZATIONS IN TERMS OF FUNCTIONS PERFORMED FOR SOCIETY. FOUR MAJOR COMPONENTS OF ACTION SYSTEMS USED TO COMPARE SEVERAL ORGANIZATIONS WERE IDENTIFIED AS FOLLOWS--(1) THE ORIENTATION…

  15. Comparison of Selected Metals Content in Cambodian Striped Snakehead Fish (Channa striata) Using Solar Drying System and Open Sun Drying

    PubMed Central

    Abu Bakar, Nur Faizah; Fudholi, Ahmad; Ruslan, Mohd Hafidz; Saroeun, Im

    2015-01-01

    The content of 12 elements in Cambodian dried striped snakehead fish was determined using inductively coupled plasma mass spectrometry. The present study compares the level of the trace toxic metals and nutritional trace elements in the fish processed using solar drying system (SDS) and open sun drying (OSD). The skin of SDS fish has lower level of As, Pb, and Cd compared to the OSD sample. As such, the flesh of the fish accumulated higher amount of toxic metals during OSD compared to SDS. However, arsenic was detected in both samples within the safe limit. The nutritional elements (Fe, Mn, Mg, Se, Mo, Cu, Ni, and Cr) were higher in the skin sample SDS fish compared to OSD fish. These beneficial metals were not accumulated in the flesh sample SDS fish demonstrating lower level compared to drying under conventional system. The reddish coloration of the SDS fish was due to the presence of high Cu content in both the skin and flesh samples which possibly account for no mold formation 5 days after packaging. As conclusion, drying of Cambodian C. striata using solar-assisted system has proven higher content of the nutritious elements compared to using the conventional system despite only slight difference in the toxic metals level between the two systems. PMID:25688274

  16. Separate collection of household food waste for anaerobic degradation - Comparison of different techniques from a systems perspective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstad, A., E-mail: Anna.bernstad@chemeng.lth.se; Cour Jansen, J. la

    Highlight: Black-Right-Pointing-Pointer Four modern and innovative systems for household food waste collection are compared. Black-Right-Pointing-Pointer Direct emissions and resource use were based on full-scale data. Black-Right-Pointing-Pointer Conservation of nutrients/energy content over the system was considered. Black-Right-Pointing-Pointer Systems with high energy/nutrient recovery are most environmentally beneficial. - Abstract: Four systems for household food waste collection are compared in relation the environmental impact categories eutrophication potential, acidification potential, global warming potential as well as energy use. Also, a hotspot analysis is performed in order to suggest improvements in each of the compared collection systems. Separate collection of household food waste in papermore » bags (with and without drying prior to collection) with use of kitchen grinders and with use of vacuum system in kitchen sinks were compared. In all cases, food waste was used for anaerobic digestion with energy and nutrient recovery in all cases. Compared systems all resulted in net avoidance of assessed environmental impact categories; eutrophication potential (-0.1 to -2.4 kg NO{sub 3}{sup -}eq/ton food waste), acidification potential (-0.4 to -1.0 kg SO{sub 2}{sup -}eq/ton food waste), global warming potential (-790 to -960 kg CO{sub 2}{sup -}eq/ton food waste) and primary energy use (-1.7 to -3.6 GJ/ton food waste). Collection with vacuum system results in the largest net avoidance of primary energy use, while disposal of food waste in paper bags for decentralized drying before collection result in a larger net avoidance of global warming, eutrophication and acidification. However, both these systems not have been taken into use in large scale systems yet and further investigations are needed in order to confirm the outcomes from the comparison. Ranking of scenarios differ largely if considering only emissions in the foreground system, indicating the importance of taking also downstream emissions into consideration when comparing different collection systems. The hot spot identification shows that losses of organic matter in mechanical pretreatment as well as tank connected food waste disposal systems and energy in drying and vacuum systems reply to the largest impact on the results in each system respectively.« less

  17. Comparative Evaluations of Four Specification Methods for Real-Time Systems

    DTIC Science & Technology

    1989-12-01

    December 1989 Comparative Evaluations of Four Specification Methods for Real - Time Systems David P. Wood William G. Wood Specification and Design Methods...Methods for Real - Time Systems Abstract: A number of methods have been proposed in the last decade for the specification of system and software requirements...and software specification for real - time systems . Our process for the identification of methods that meet the above criteria is described in greater

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koh, J. H.; Robertson, A.; Jonkman, J.

    Need to modify simulated system behavior to the measured data, but the tower wind loads improved the comparison for nonoperating conditions. the SWAY system in both turbine operating and nonoperating conditions. Mixed results were observed when comparing the simulated system behavior to the measured data, but the tower wind loads improved the comparison for nonoperating conditions. without the new tower-load capability to examine its influence on the response characteristics of the system. This is important in situations when the turbine is parked in survival conditions. The simulation results were then compared to measured data from the SWAY system in bothmore » turbine operating and nonoperating conditions. Mixed results were observed when comparing the simulated system behavior to the measured data, but the tower wind loads improved the comparison for nonoperating conditions.« less

  19. A fully battery-powered inexpensive spectrophotometric system for high-sensitivity point-of-care analysis on a microfluidic chip

    PubMed Central

    Dou, Maowei; Lopez, Juan; Rios, Misael; Garcia, Oscar; Xiao, Chuan; Eastman, Michael

    2016-01-01

    A cost-effective battery-powered spectrophotometric system (BASS) was developed for quantitative point-of-care (POC) analysis on a microfluidic chip. By using methylene blue as a model analyte, we first compared the performance of the BASS with a commercial spectrophotometric system, and further applied the BASS for loop-mediated isothermal amplification (LAMP) detection and subsequent quantitative nucleic acid analysis which exhibited a comparable limit of detection to that of Nanodrop. Compared to the commercial spectrophotometric system, our spectrophotometric system is lower-cost, consumes less reagents, and has a higher detection sensitivity. Most importantly, it does not rely on external power supplies. All these features make our spectrophotometric system highly suitable for a variety of POC analyses, such as field detection. PMID:27143408

  20. The use of discrete-event simulation modeling to compare handwritten and electronic prescribing systems.

    PubMed

    Ghany, Ahmad; Vassanji, Karim; Kuziemsky, Craig; Keshavjee, Karim

    2013-01-01

    Electronic prescribing (e-prescribing) is expected to bring many benefits to Canadian healthcare, such as a reduction in errors and adverse drug reactions. As there currently is no functioning e-prescribing system in Canada that is completely electronic, we are unable to evaluate the performance of a live system. An alternative approach is to use simulation modeling for evaluation. We developed two discrete-event simulation models, one of the current handwritten prescribing system and one of a proposed e-prescribing system, to compare the performance of these two systems. We were able to compare the number of processes in each model, workflow efficiency, and the distribution of patients or prescriptions. Although we were able to compare these models to each other, using discrete-event simulation software was challenging. We were limited in the number of variables we could measure. We discovered non-linear processes and feedback loops in both models that could not be adequately represented using discrete-event simulation software. Finally, interactions between entities in both models could not be modeled using this type of software. We have come to the conclusion that a more appropriate approach to modeling both the handwritten and electronic prescribing systems would be to use a complex adaptive systems approach using agent-based modeling or systems-based modeling.

  1. Comparative effectiveness: its role in the healthcare system.

    PubMed

    Brown, Melissa M; Luo, Betsy; Brown, Heidi C; Brown, Gary C

    2009-05-01

    To describe comparative effectiveness and assess its role in crafting new healthcare policy. Senate Bill S.3408 would establish a nongovernment-affiliated Healthcare Comparative Effectiveness Research Institute that would work with healthcare experts and stakeholders in healthcare to prioritize interventions and services to be studied. A value-based medicine system of standardized comparative effectiveness and cost-effectiveness data using utilities would allow physicians to assess the total value (improvement in quality of life and/or length of life) conferred by interventions. Standardized comparativeness and cost-effectiveness data will give physicians an information system to identify the interventions that confer the greatest value to patients, and thus deliver higher quality care than possible with evidence-based data alone while allowing the most cost-effective care.

  2. Metacognition and the Influence of Polling Systems: How Do Clickers Compare with Low Technology Systems

    ERIC Educational Resources Information Center

    Brady, Melanie; Seli, Helena; Rosenthal, Jane

    2013-01-01

    Recent research suggests that clickers (electronic feedback devices) influence metacognition. This article reports qualitative findings from a quasi-experimental study comparing clickers and low technology polling. We sought to establish how clickers influence metacognition and whether differences exist in how each response system influences…

  3. The TREC Interactive Track: An Annotated Bibliography.

    ERIC Educational Resources Information Center

    Over, Paul

    2001-01-01

    Discussion of the study of interactive information retrieval (IR) at the Text Retrieval Conferences (TREC) focuses on summaries of the Interactive Track at each conference. Describes evolution of the track, which has changed from comparing human-machine systems with fully automatic systems to comparing interactive systems that focus on the search…

  4. Performance and energy systems contributions during upper-body sprint interval exercise

    PubMed Central

    Franchini, Emerson; Takito, Monica Yuri; Dal’Molin Kiss, Maria Augusta Peduti

    2016-01-01

    The main purpose of this study was to investigate the performance and energy systems contribution during four upper-body Wingate tests interspersed by 3-min intervals. Fourteen well-trained male adult Judo athletes voluntarily took part in the present study. These athletes were from state to national level, were in their competitive period, but not engaged in any weight loss procedure. Energy systems contributions were estimated using oxygen uptake and blood lactate measurements. The main results indicated that there was higher glycolytic contribution compared to oxidative (P<0.001) during bout 1, but lower glycolytic contribution was observed compared to the phosphagen system (adenosine triphosphate-creatine phosphate, ATP-PCr) contribution during bout 3 (P<0.001), lower glycolytic contribution compared to oxidative and ATP-PCr (P<0.001 for both comparisons) contributions during bout 4 and lower oxidative compared to ATP-PCr during bout 4 (P=0.040). For the energy system contribution across Wingate bouts, the ATP-PCr contribution during bout 1 was lower than that observed during bout 4 (P=0.005), and the glycolytic system presented higher percentage contribution in the first bout compared to the third and fourth bouts (P<0.001 for both comparisons), and higher percentage participation in the second compared to the fourth bout (P<0.001). These results suggest that absolute oxidative and ATP-PCr participations were kept constant across Wingate tests, but there was an increase in relative participation of ATP-PCr in bout 4 compared to bout 1, probably due to the partial phosphocreatine resynthesis during intervals and to the decreased glycolytic activity. PMID:28119874

  5. LOX/GOX mechanical impact tester assessment

    NASA Technical Reports Server (NTRS)

    Bransford, J. W.; Bryan, C. J.; Frye, G. W.; Stohler, S. L.

    1980-01-01

    The performances of three existing high pressure oxygen mechanical impact test systems were tested at two different test sites. The systems from one test site were fabricated from the same design drawing, whereas the system tested at the other site was of different design. Energy delivered to the test sample for each test system was evaluated and compared. Results were compared to the reaction rates obtained.

  6. Precision displacement reference system

    DOEpatents

    Bieg, Lothar F.; Dubois, Robert R.; Strother, Jerry D.

    2000-02-22

    A precision displacement reference system is described, which enables real time accountability over the applied displacement feedback system to precision machine tools, positioning mechanisms, motion devices, and related operations. As independent measurements of tool location is taken by a displacement feedback system, a rotating reference disk compares feedback counts with performed motion. These measurements are compared to characterize and analyze real time mechanical and control performance during operation.

  7. Comparative Analysis of Enrollment and Financial Strength of Private Institutions. AIR 1989 Annual Forum Paper.

    ERIC Educational Resources Information Center

    Glover, Robert H.; Mills, Michael R.

    A research design, decision support system, and results of a comparative analysis of enrollment and financial strength (of private institutions granting masters and doctoral degrees) are presented. Cluster analysis, discriminant analysis, multiple regression, and an interactive decision support system are used to compare the enrollment and…

  8. Comparing Synchronous Virtual Classrooms: Student, Instructor and Course Designer Perspectives

    ERIC Educational Resources Information Center

    Lavolette, Elizabeth; Venable, Melissa A.; Gose, Eddie; Huang, Eric

    2010-01-01

    The synchronous tool that is right for developing an online course depends on the context, needs and priorities. This report compares synchronous, virtual classroom systems Elluminate Live! v. 9 and Dimdim v. 4.5. The researchers compared the features of each system in terms of facilitation of communication, presentation of course content and…

  9. A novel photovoltaic power system which uses a large area concentrator mirror

    NASA Technical Reports Server (NTRS)

    Arrison, Anne; Fatemi, Navid

    1987-01-01

    A preliminary analysis has been made of a novel photovoltaic power system concept. The system is composed of a small area, dense photovoltaic array, a large area solar concentrator, and a battery system for energy storage. The feasibility of such a system is assessed for space power applications. The orbital efficiency, specific power, mass, and area of the system are calculated under various conditions and compared with those for the organic Rankine cycle solar dynamic system proposed for Space Station. Near term and advanced large area concentrator photovoltaic systems not only compare favorably to solar dynamic systems in terms of performance but offer other benefits as well.

  10. Isotope Geochemistry for Comparative Planetology of Exoplanets

    NASA Technical Reports Server (NTRS)

    Mandt, K. E.; Atreya, S.; Luspay-Kuti, A.; Mousis, O.; Simon, A.; Hofstadter, M. D.

    2017-01-01

    Isotope geochemistry has played a critical role in understanding processes at work in and the history of solar system bodies. Application of these techniques to exoplanets would be revolutionary and would allow comparative planetology with the formation and evolution of exoplanet systems. The roadmap for comparative planetology of the origins and workings of exoplanets involves isotopic geochemistry efforts in three areas: (1) technology development to expand observations of the isotopic composition of solar system bodies and expand observations to isotopic composition of exoplanet atmospheres; (2) theoretical modeling of how isotopes fractionate and the role they play in evolution of exoplanetary systems, atmospheres, surfaces and interiors; and (3) laboratory studies to constrain isotopic fractionation due to processes at work throughout the solar system.

  11. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

    PubMed

    Dietrich, Tobias J; Pfirrmann, Christian W A; Schwab, Alexander; Pankalla, Katja; Buck, Florian M

    2013-07-01

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90° allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 ± 231.7 cGy*cm(2) versus biplanar X-ray system: 158.4 ± 103.8 cGy*cm(2)). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time.

  12. Learning in a Simple Motor System

    ERIC Educational Resources Information Center

    Broussard, Dianne M.; Kassardjian, Charles D.

    2004-01-01

    Motor learning is a very basic, essential form of learning that appears to share common mechanisms across different motor systems. We evaluate and compare a few conceptual models for learning in a relatively simple neural system, the vestibulo-ocular reflex (VOR) of vertebrates. We also compare the different animal models that have been used to…

  13. Comparative Education: The Social Construction of the Modern World System.

    ERIC Educational Resources Information Center

    Ramirez, Francisco O.; Meyer, John W.

    This paper is a critical assessment of the theory and evidence on three general issues in comparative education. It assesses the factors affecting the origins and expansion of national educational systems; the factors influencing the organizational structure and ideologies of systems of mass schooling and higher education; and the effects of…

  14. Influence of commercial laying hen housing systems on the incidence and identification of Salmonella and Campylobacter

    USDA-ARS?s Scientific Manuscript database

    The housing of laying hens is important for social, industrial, and regulatory aspects. Many studies have compared hen housing systems on the research farm, but few have fully examined commercial housing systems and management strategies. The current study compared hens housed in commercial cage-f...

  15. Cyanate Ester and Phthalonitrile Impregnated Carbon Ablative TPS

    NASA Technical Reports Server (NTRS)

    Boghozian, Tane; Stackpoole, Margaret M.; Gasch, Matt

    2016-01-01

    Phenolic resin has extensive heritage as a TPS (Thermal Protection Systems) material, however, alternative resin systems such as Cyanate Ester and Phthalonitrile may offer improved performance compared to state-of-the-art phenolic resin. These alternative resin systems may have higher char yield, higher char strength, lower thermal conductivity and improved mechanical properties. In current work at NASA Ames alternative resin systems were uniformly infused into fibrous substrates and preliminary properties characterized. The density of the cyanate ester infused in fibrous substrate ranged from 0.25-0.3 grams per cubic centimeter compared to PICA (Phenolic resin impregnated carbon ablative) having a density of approximately 0.25 grams per cubic centimeter. The density of Phthalonitrile varies from 0.22-0.25 grams per cubic centimeter. Initial formulations of these new resin systems were recently tested at the LARC HyMETs (Hypersonic Materials Environmental Test System) facility to evaluate their performance and data such as back face temperature, char yield, and recession are compared to PICA. Cyanate Ester and Phthalonitrile impregnated carbon ablative samples showed comparable performance to phenolic resin impregnated carbon ablative samples.

  16. Ximelagatran compared with warfarin for the prevention of systemic embolism and stroke. An imputed placebo analysis.

    PubMed

    Berry, Colin; Norrie, John; McMurray, John J V

    2005-03-01

    The active control trials, SPORTIF III and SPORTIF V, compared the direct thrombin inhibitor ximelagatran to warfarin, where each was given as a treatment to prevent systemic embolism and stroke in patients with atrial fibrillation. Because warfarin has previously been compared to placebo in similar patients and ximelagatran has now been compared to warfarin, an indirect comparison between ximelagatran and placebo is possible (imputed placebo analysis). In this analysis, ximelagatran reduces the risk of stroke and systemic embolism by 66% (hazard ratio 0.338; 95% confidence interval [CI] 0.204-0.560). Ximelagatran preserves 102% (95% CI 72-132%) of the benefit of warfarin. Based on these data, ximelagatran may be an effective alternative to warfarin for the prevention of stroke and systemic embolism in high-risk patients with atrial fibrillation.

  17. Comparative study of popular objective functions for damping power system oscillations in multimachine system.

    PubMed

    Islam, Naz Niamul; Hannan, M A; Shareef, Hussain; Mohamed, Azah; Salam, M A

    2014-01-01

    Power oscillation damping controller is designed in linearized model with heuristic optimization techniques. Selection of the objective function is very crucial for damping controller design by optimization algorithms. In this research, comparative analysis has been carried out to evaluate the effectiveness of popular objective functions used in power system oscillation damping. Two-stage lead-lag damping controller by means of power system stabilizers is optimized using differential search algorithm for different objective functions. Linearized model simulations are performed to compare the dominant mode's performance and then the nonlinear model is continued to evaluate the damping performance over power system oscillations. All the simulations are conducted in two-area four-machine power system to bring a detailed analysis. Investigated results proved that multiobjective D-shaped function is an effective objective function in terms of moving unstable and lightly damped electromechanical modes into stable region. Thus, D-shape function ultimately improves overall system damping and concurrently enhances power system reliability.

  18. 3-Chloro-1,2-propanediol biodegradation by Ca-alginate immobilized Pseudomonas putida DSM 437 cells applying different processes: mass transfer effects.

    PubMed

    Konti, Aikaterini; Mamma, Diomi; Hatzinikolaou, Dimitios G; Kekos, Dimitris

    2016-10-01

    3-Chloro-1,2-propanediol (3-CPD) biodegradation by Ca-alginate immobilized Pseudomonas putida cells was performed in batch system, continuous stirred tank reactor (CSTR), and packed-bed reactor (PBR). Batch system exhibited higher biodegradation rates and 3-CPD uptakes compared to CSTR and PBR. The two continuous systems (CSTR and PBR) when compared at 200 mg/L 3-CPD in the inlet exhibited the same removal of 3-CPD at steady state. External mass-transfer limitations are found negligible at all systems examined, since the observable modulus for external mass transfer Ω ≪ 1 and the Biot number Bi > 1. Intra-particle diffusion resistance had a significant effect on 3-CPD biodegradation in all systems studied, but to a different extent. Thiele modulus was in the range of 2.5 in batch system, but it was increased at 11 when increasing cell loading in the beads, thus lowering significantly the respective effectiveness factor. Comparing the systems at the same cell loading in the beads PBR was less affected by internal diffusional limitations compared to CSTR and batch system, and, as a result, exhibited the highest overall effectiveness factor.

  19. EHR standards--A comparative study.

    PubMed

    Blobel, Bernd; Pharow, Peter

    2006-01-01

    For ensuring quality and efficiency of patient's care, the care paradigm moves from organization-centered over process-controlled towards personal care. Such health system paradigm change leads to new paradigms for analyzing, designing, implementing and deploying supporting health information systems including EHR systems as core application in a distributed eHealth environment. The paper defines the architectural paradigm for future-proof EHR systems. It compares advanced EHR architectures referencing them at the Generic Component Model. The paper introduces the evolving paradigm of autonomous computing for self-organizing health information systems.

  20. CMG-Biotools, a Free Workbench for Basic Comparative Microbial Genomics

    PubMed Central

    Vesth, Tammi; Lagesen, Karin; Acar, Öncel; Ussery, David

    2013-01-01

    Background Today, there are more than a hundred times as many sequenced prokaryotic genomes than were present in the year 2000. The economical sequencing of genomic DNA has facilitated a whole new approach to microbial genomics. The real power of genomics is manifested through comparative genomics that can reveal strain specific characteristics, diversity within species and many other aspects. However, comparative genomics is a field not easily entered into by scientists with few computational skills. The CMG-biotools package is designed for microbiologists with limited knowledge of computational analysis and can be used to perform a number of analyses and comparisons of genomic data. Results The CMG-biotools system presents a stand-alone interface for comparative microbial genomics. The package is a customized operating system, based on Xubuntu 10.10, available through the open source Ubuntu project. The system can be installed on a virtual computer, allowing the user to run the system alongside any other operating system. Source codes for all programs are provided under GNU license, which makes it possible to transfer the programs to other systems if so desired. We here demonstrate the package by comparing and analyzing the diversity within the class Negativicutes, represented by 31 genomes including 10 genera. The analyses include 16S rRNA phylogeny, basic DNA and codon statistics, proteome comparisons using BLAST and graphical analyses of DNA structures. Conclusion This paper shows the strength and diverse use of the CMG-biotools system. The system can be installed on a vide range of host operating systems and utilizes as much of the host computer as desired. It allows the user to compare multiple genomes, from various sources using standardized data formats and intuitive visualizations of results. The examples presented here clearly shows that users with limited computational experience can perform complicated analysis without much training. PMID:23577086

  1. TRADITIONAL CANISTER-BASED OPEN WASTE MANAGEMENT SYSTEM VERSUS CLOSED SYSTEM: HAZARDOUS EXPOSURE PREVENTION AND OPERATING THEATRE STAFF SATISFACTION.

    PubMed

    Horn, M; Patel, N; MacLellan, D M; Millard, N

    2016-06-01

    Exposure to blood and body fluids is a major concern to health care professionals working in operating rooms (ORs). Thus, it is essential that hospitals use fluid waste management systems that minimise risk to staff, while maximising efficiency. The current study compared the utility of a 'closed' system with a traditional canister-based 'open' system in the OR in a private hospital setting. A total of 30 arthroscopy, urology, and orthopaedic cases were observed. The closed system was used in five, four, and six cases, respectively and the open system was used in nine, two, and four cases, respectively. The average number of opportunities for staff to be exposed to hazardous fluids were fewer for the closed system when compared to the open during arthroscopy and urology procedures. The open system required nearly 3.5 times as much staff time for set-up, maintenance during procedures, and post-procedure disposal of waste. Theatre staff expressed greater satisfaction with the closed system than with the open. In conclusion, compared with the open system, the closed system offers a less hazardous and more efficient method of disposing of fluid waste generated in the OR.

  2. Validity of Torque-Data Collection at Multiple Sites: A Framework for Collaboration on Clinical-Outcomes Research in Sports Medicine.

    PubMed

    Kuenze, Christopher; Eltouhky, Moataz; Thomas, Abbey; Sutherlin, Mark; Hart, Joseph

    2016-05-01

    Collecting torque data using a multimode dynamometer is common in sports-medicine research. The error in torque measurements across multiple sites and dynamometers has not been established. To assess the validity of 2 calibration protocols across 3 dynamometers and the error associated with torque measurement for each system. Observational study. 3 university laboratories at separate institutions. 2 Biodex System 3 dynamometers and 1 Biodex System 4 dynamometer. System calibration was completed using the manufacturer-recommended single-weight method and an experimental calibration method using a series of progressive weights. Both calibration methods were compared with a manually calculated theoretical torque across a range of applied weights. Relative error, absolute error, and percent error were calculated at each weight. Each outcome variable was compared between systems using 95% confidence intervals across low (0-65 Nm), moderate (66-110 Nm), and high (111-165 Nm) torque categorizations. Calibration coefficients were established for each system using both calibration protocols. However, within each system the calibration coefficients generated using the single-weight (System 4 = 2.42 [0.90], System 3a = 1.37 [1.11], System 3b = -0.96 [1.45]) and experimental calibration protocols (System 4 = 3.95 [1.08], System 3a = -0.79 [1.23], System 3b = 2.31 [1.66]) were similar and displayed acceptable mean relative error compared with calculated theoretical torque values. Overall, percent error was greatest for all 3 systems in low-torque conditions (System 4 = 11.66% [6.39], System 3a = 6.82% [11.98], System 3b = 4.35% [9.49]). The System 4 significantly overestimated torque across all 3 weight increments, and the System 3b overestimated torque over the moderate-torque increment. Conversion of raw voltage to torque values using the single-calibration-weight method is valid and comparable to a more complex multiweight calibration process; however, it is clear that calibration must be done for each individual system to ensure accurate data collection.

  3. Field test and simulation evaluation of variable refrigerant flow systems performance

    DOE PAGES

    Lee, Je Hyeon; Im, Piljae; Song, Young-hak

    2017-10-24

    Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. Themore » same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.« less

  4. Field test and simulation evaluation of variable refrigerant flow systems performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Je Hyeon; Im, Piljae; Song, Young-hak

    Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. Themore » same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.« less

  5. Slot scanning versus antiscatter grid in digital mammography: comparison of low-contrast performance using contrast-detail measurement

    NASA Astrophysics Data System (ADS)

    Lai, Chao-Jen; Shaw, Chris C.; Geiser, William; Kappadath, Srinivas C.; Liu, Xinming; Wang, TianPeng; Tu, Shu-Ju; Altunbas, Mustafa C.

    2004-05-01

    Slot scanning imaging techniques allow for effective scatter rejection without attenuating primary x-rays. The use of these techniques should generate better image quality for the same mean glandular dose (MGD) or a similar image quality for a lower MGD as compared to imaging techniques using an anti-scatter grid. In this study, we compared a slot scanning digital mammography system (SenoScan, Fisher Imaging Systems, Denver, CO) to a full-field digital mammography (FFDM) system used in conjunction with a 5:1 anti-scatter grid (SenoGraphe 2000D, General Electric Medical Systems, Milwaukee, WI). Images of a contrast-detail phantom (University Hospital Nijmegen, The Netherlands) were reviewed to measure the contrast-detail curves for both systems. These curves were measured at 100%, 71%, 49% and 33% of the reference mean glandular dose (MGD), as determined by photo-timing, for the Fisher system and 100% for the GE system. Soft-copy reading was performed on review workstations provided by the manufacturers. The correct observation ratios (CORs) were also computed and used to compare the performance of the two systems. The results showed that, based on the contrast-detail curves, the performance of the Fisher images, acquired at 100% and 71% of the reference MGD, was comparable to the GE images at 100% of the reference MGD. The CORs for Fisher images were 0.463 and 0.444 at 100% and 71% of the reference MGD, respectively, compared to 0.453 for the GE images at 100% of the reference MGD.

  6. Advancement in Productivity of Arabic into English Machine Translation Systems from 2008 to 2013

    ERIC Educational Resources Information Center

    Abu-Al-Sha'r, Awatif M.; AbuSeileek, Ali F.

    2013-01-01

    This paper attempts to compare between the advancements in the productivity of Arabic into English Machine Translation Systems between two years, 2008 and 2013. It also aims to evaluate the progress achieved by various systems of Arabic into English electronic translation between the two years. For tracing such advancement, a comparative analysis…

  7. What Can Be Learned from a Comparison of Two Agricultural Knowledge Systems? The Case of the Netherlands and Israel.

    ERIC Educational Resources Information Center

    Blum, Abraham

    1991-01-01

    Compared the agricultural knowledge systems (AKS) of the Netherlands and Israel; analyzed the features that made the systems effective and applicable to other countries. The analysis discovered eight elements that explain the success of these AKSs and demonstrated the value of comparative case studies. (JOW)

  8. Automatic visual inspection system for microelectronics

    NASA Technical Reports Server (NTRS)

    Micka, E. Z. (Inventor)

    1975-01-01

    A system for automatically inspecting an integrated circuit was developed. A device for shining a scanning narrow light beam at an integrated circuit to be inspected and another light beam at an accepted integrated circuit was included. A pair of photodetectors that receive light reflected from these integrated circuits, and a comparing system compares the outputs of the photodetectors.

  9. Comparative Analysis.

    DTIC Science & Technology

    1987-11-01

    differential qualita- tive (DQ) analysis, which solves the task, providing explanations suitable for use by design systems, automated diagnosis, intelligent...solves the task, providing explanations suitable for use by design systems, automated diagnosis, intelligent tutoring systems, and explanation based...comparative analysis as an important component; the explanation is used in many different ways. * One way method of automated design is the principlvd

  10. Comparative Evaluation of Phase 1 Results from the Energy Conversion Alternatives Study (ECAS). [coal utilization for electric power plants feasibility analysis

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Ten advanced energy conversion systems for central-station, based-load electric power generation using coal and coal-derived fuels which were studied by NASA are presented. Various contractors were selected by competitive bidding to study these systems. A comparative evaluation is provided of the contractor results on both a system-by-system and an overall basis. Ground rules specified by NASA, such as coal specifications, fuel costs, labor costs, method of cost comparison, escalation and interest during construction, fixed charges, emission standards, and environmental conditions, are presented. Each system discussion includes the potential advantages of the system, the scope of each contractor's analysis, typical schematics of systems, comparison of cost of electricity and efficiency for each contractor, identification and reconciliation of differences, identification of future improvements, and discussion of outside comments. Considerations common to all systems, such as materials and furnaces, are also discussed. Results of selected in-house analyses are presented, in addition to contractor data. The results for all systems are then compared.

  11. Comparison of China's Environmental Impact Assessment (EIA) law with the European Union (EU) EIA Directive.

    PubMed

    Chen, Qiaoling; Zhang, Yuanzhi; Ekroos, Ari

    2007-09-01

    In this paper, we first review the development of China's Environmental Impact Assessment (EIA) system in the past 30 years. Then we compare the framework and operational procedures of China's new EIA law with those of the EU EIA Directive. We also compare public participation, as well as sanctions and control in the two EIA systems. In addition, we identify where the processes in both EIA systems are similar or different from one another. By comparison, we noted that there are at least three obvious weaknesses in China's EIA system: (1) the application of new models for EIA legislation; (2) the improvement of EIA guidance and education; and (3) the enhancement of public participation in EIA process. Our study indicates that these three major shortcomings should be overcome and improved in China's EIA system, when compared with the EU EIA system.

  12. Dielectric properties of grain-grainboundary binary system

    NASA Astrophysics Data System (ADS)

    Cheng, Peng-Fei; Li, Sheng-Tao; Wang, Hui

    2014-09-01

    Dielectric properties of grain-grainboundary binary system are analyzed theoretically and compared with unary system and classical Maxwell-Wagner (MW) polarization in binary system. It is found that MW polarization appears at higher frequency compared with intrinsic polarization for grain-grainboundary binary system, which is abnormal compared with classical dielectric theory. This dielectric anomaly is premised on the existence of electronic relaxation at grainboundary. The origin of giant dielectric constant of CaCu3Ti4O12 (CCTO) ceramics is also investigated on the basis of the theoretical results. It is proposed that low frequency relaxation originates from electronic relaxation of oxygen vacancy at depletion layer, while high frequency relaxation comes from MW polarization. The results of this paper offer a quantitative identification of MW polarization from intrinsic polarization at grainboundary and a judgment of the mechanism and location of a certain polarization in grain-grainboundary binary system.

  13. Performance and economics of the ACES and alternative residential heating and air conditioning systems in 115 US cities

    NASA Astrophysics Data System (ADS)

    Abbatiello, L. A.; Nephew, E. A.; Ballou, M. L.

    1981-03-01

    The efficiency and life cycle costs of the brine chiller minimal annual cycle energy system (ACES) for residential space heating, air conditioning, and water heating requirements are compared with three conventional systems. The conventional systems evaluated are a high performance air-to-air heat pump with an electric resistance water heater, an electric furnace with a central air conditioner and an electric resistance water heater, and a high performance air-to-air heat pump with a superheater unit for hot water production. Monthly energy requirements for a reference single family house are calculated, and the initial cost and annual energy consumption of the systems, providing identical energy services, are computed and compared. The ACES consumes one third to one half ot the electrical energy required by the conventional systems and delivers the same annual loads at comparable costs.

  14. Advanced Propulsion Power Distribution System for Next Generation Electric/Hybrid Vehicle. Phase 1; Preliminary System Studies

    NASA Technical Reports Server (NTRS)

    Bose, Bimal K.; Kim, Min-Huei

    1995-01-01

    The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.

  15. Comparing Different Fault Identification Algorithms in Distributed Power System

    NASA Astrophysics Data System (ADS)

    Alkaabi, Salim

    A power system is a huge complex system that delivers the electrical power from the generation units to the consumers. As the demand for electrical power increases, distributed power generation was introduced to the power system. Faults may occur in the power system at any time in different locations. These faults cause a huge damage to the system as they might lead to full failure of the power system. Using distributed generation in the power system made it even harder to identify the location of the faults in the system. The main objective of this work is to test the different fault location identification algorithms while tested on a power system with the different amount of power injected using distributed generators. As faults may lead the system to full failure, this is an important area for research. In this thesis different fault location identification algorithms have been tested and compared while the different amount of power is injected from distributed generators. The algorithms were tested on IEEE 34 node test feeder using MATLAB and the results were compared to find when these algorithms might fail and the reliability of these methods.

  16. Statistical Evaluation of Voltage Variation of Power Distribution System with Clustered Home-Cogeneration Systems

    NASA Astrophysics Data System (ADS)

    Kato, Takeyoshi; Minagata, Atsushi; Suzuoki, Yasuo

    This paper discusses the influence of mass installation of a home co-generation system (H-CGS) using a polymer electrolyte fuel cell (PEFC) on the voltage profile of power distribution system in residential area. The influence of H-CGS is compared with that of photovoltaic power generation systems (PV systems). The operation pattern of H-CGS is assumed based on the electricity and hot-water demand observed in 10 households for a year. The main results are as follows. With the clustered H-CGS, the voltage of each bus is higher by about 1-3% compared with the conventional system without any distributed generators. Because H-CGS tends to increase the output during the early evening, H-CGS contributes to recover the voltage drop during the early evening, resulting in smaller voltage variation of distribution system throughout a day. Because of small rated power output about 1kW, the influence on voltage profile by the clustered H-CGS is smaller than that by the clustered PV systems. The highest voltage during the day time is not so high as compared with the distribution system with the clustered PV systems, even if the reverse power flow from H-CGS is allowed.

  17. Comparison of Errors Using Two Length-Based Tape Systems for Prehospital Care in Children.

    PubMed

    Rappaport, Lara D; Brou, Lina; Givens, Tim; Mandt, Maria; Balakas, Ashley; Roswell, Kelley; Kotas, Jason; Adelgais, Kathleen M

    2016-01-01

    The use of a length/weight-based tape (LBT) for equipment size and drug dosing for pediatric patients is recommended in a joint statement by multiple national organizations. A new system, known as Handtevy™, allows for rapid determination of critical drug doses without performing calculations. To compare two LBT systems for dosing errors and time to medication administration in simulated prehospital scenarios. This was a prospective randomized trial comparing the Broselow Pediatric Emergency Tape™ (Broselow) and Handtevy LBT™ (Handtevy). Paramedics performed 2 pediatric simulations: cardiac arrest with epinephrine administration and hypoglycemia mandating dextrose. Each scenario was repeated utilizing both systems with a 1-year-old and 5-year-old size manikin. Facilitators recorded identified errors and time points of critical actions including time to medication. We enrolled 80 paramedics, performing 320 simulations. For Dextrose, there were significantly more errors with Broselow (63.8%) compared to Handtevy (13.8%) and time to administration was longer with the Broselow system (220 seconds vs. 173 seconds). For epinephrine, the LBTs were similar in overall error rate (Broselow 21.3% vs. Handtevy 16.3%) and time to administration (89 vs. 91 seconds). Cognitive errors were more frequent when using the Broselow compared to Handtevy, particularly with dextrose administration. The frequency of procedural errors was similar between the two LBT systems. In simulated prehospital scenarios, use of the Handtevy LBT system resulted in fewer errors for dextrose administration compared to the Broselow LBT, with similar time to administration and accuracy of epinephrine administration.

  18. Hepatic Arterial Infusion in Combination with Modern Systemic Chemotherapy is Associated with Improved Survival Compared with Modern Systemic Chemotherapy Alone in Patients with Isolated Unresectable Colorectal Liver Metastases: A Case-Control Study.

    PubMed

    Dhir, Mashaal; Jones, Heather L; Shuai, Yongli; Clifford, Amber K; Perkins, Samantha; Steve, Jennifer; Hogg, Melissa E; Choudry, M Haroon A; Pingpank, James F; Holtzman, Matthew P; Zeh, Herbert J; Bahary, Nathan; Bartlett, David L; Zureikat, Amer H

    2017-01-01

    In the era of effective modern systemic chemotherapy (CT), the role of hepatic arterial infusion of fluoxuridine (HAI-FUDR) in the treatment of isolated unresectable colorectal liver metastasis (IU-CRCLM) remains controversial. This study aimed to compare the overall survival (OS) of HAI-FUDR in combination with modern systemic CT versus modern systemic CT alone in patients with IU-CRCLM. This was a case-control study of IU-CRCLM patients who underwent HAI + modern systemic CT or modern systemic CT alone. Modern systemic CT was defined as the use of multidrug regimens containing oxaliplatin and/or irinotecan ± biologics. Overall, 86 patients met the inclusion criteria (n = 40 for the HAI + CT group, and n = 46 for the CT-alone group). Both groups were similar in demographics, primary and stage IV tumor characteristics, and treatment-related variables (carcinoembryonic antigen, use of biologic agents, total number of lines of systemic CT administered) (all p > 0.05). Additionally, both groups were comparable with respect to liver tumor burden [median number of lesions (13.5 vs. 15), percentage of liver tumor replacement (37.5 vs. 40 %), and size of largest lesion] (all p > 0.05). Median OS in the HAI + CT group was 32.8 months compared with 15.3 months in the CT-alone group (p < 0.0001). Multivariate analysis revealed HAI + CT (hazard ratio 0.4, 95 % confidence interval 0.21-0.72; p = 0.003), Eastern Cooperative Oncology Group status, and receipt of increasing number of lines of systemic CT to be independent predictors of survival. In this case-control study of patients with IU-CRCLM, HAI in combination with CT was associated with improved OS when compared with modern systemic CT alone.

  19. 3D digital subtraction angiography of intracranial aneurysms: comparison of flat panel detector with conventional image intensifier TV system using a vascular phantom.

    PubMed

    Kakeda, S; Korogi, Y; Ohnari, N; Hatakeyama, Y; Moriya, J; Oda, N; Nishino, K; Miyamoto, W

    2007-05-01

    Compared with the image intensifier (I.I.)-TV system, the flat panel detector (FPD) system of direct conversion type has several theoretic advantages, such as higher spatial resolution, wide dynamic range, and no image distortion. The purpose of this study was to compare the image quality of 3D digital subtraction angiography (DSA) in the FPD and conventional I.I.-TV systems using a vascular phantom. An anthropomorphic vascular phantom was designed to simulate the various intracranial aneurysms with aneurysmal bleb. The tubes of this vascular phantom were filled with 2 concentrations of contrast material (300 and 150 mg I/mL), and we obtained 3D DSA using the FPD and I.I.-TV systems. First, 2 blinded radiologists compared the volume-rendering images for 3D DSA on the FPD and I.I.-TV systems, looking for pseudostenosis artifacts. Then, 2 other radiologists independently evaluated both systems for the depiction of the simulated aneurysm and aneurysmal bleb using a 5-point scale. For the degree of the pseudostenosis artifacts at the M1 segment of the middle cerebral artery at 300 mg I/mL, 3D DSA with FPD system showed mild stenoses, whereas severe stenoses were observed at 3D DSA with I.I.-TV system. At both concentrations, the FPD system was significantly superior to I.I.-TV system regarding the depiction of aneurysm and aneurysmal bleb. Compared with the I.I.-TV system, the FPD system could create high-resolution 3D DSA combined with a reduction of the pseudostenosis artifacts.

  20. Cost and size estimates for an electrochemical bulk energy storage concept

    NASA Technical Reports Server (NTRS)

    Warshay, M.; Wright, L. O.

    1975-01-01

    Preliminary capital cost and size estimates were made for a titanium trichloride, titanium tetrachloride, ferric chloride, ferrous chloride redox-flow-cell electric power system. On the basis of these preliminary estimates plus other important considerations, this electrochemical system emerged as having great promise as a bulk energy storage system for power load leveling. The size of this system is less than two per cent of that of a comparable pumped hydroelectric plant. The estimated capital cost of a 10 MW, 60- and 85-MWh redox-flow system compared well with that of competing systems.

  1. Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography.

    PubMed

    Fink, Christian; Hallscheidt, Peter J; Noeldge, Gerd; Kampschulte, Annette; Radeleff, Boris; Hosch, Waldemar P; Kauffmann, Günter W; Hansmann, Jochen

    2002-02-01

    The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.

  2. Automatic exposure control systems designed to maintain constant image noise: effects on computed tomography dose and noise relative to clinically accepted technique charts.

    PubMed

    Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; Kofler, James M; McCollough, Cynthia H

    2015-01-01

    To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise-based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects.

  3. TU-CD-207-05: A Novel Digital Tomosynthesis System Using Orthogonal Scanning Technique: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J; Park, C; Kauweloa, K

    2015-06-15

    Purpose: As an alternative to full tomographic imaging technique such as cone-beam computed tomography (CBCT), there is growing interest to adopt digital tomosynthesis (DTS) for the use of diagnostic as well as therapeutic applications. The aim of this study is to propose a new DTS system using novel orthogonal scanning technique, which can provide superior image quality DTS images compared to the conventional DTS scanning system. Methods: Unlike conventional DTS scanning system, the proposed DTS is reconstructed with two sets of orthogonal patient scans. 1) X-ray projections that are acquired along transverse trajectory and 2) an additional sets of X-raymore » projections acquired along the vertical direction at the mid angle of the previous transverse scan. To reconstruct DTS, we have used modified filtered backprojection technique to account for the different scanning directions of each projection set. We have evaluated the performance of our method using numerical planning CT data of liver cancer patient and a physical pelvis phantom experiment. The results were compared with conventional DTS techniques with single transverse and vertical scanning. Results: The experiments on both numerical simulation as well as physical experiment showed that the resolution as well as contrast of anatomical structures was much clearer using our method. Specifically, the image quality comparing with transversely scanned DTS showed that the edge and contrast of anatomical structures along Left-Right (LR) directions was comparable however, considerable discrepancy and enhancement could be observed along Superior-Inferior (SI) direction using our method. The opposite was observed when vertically scanned DTS was compared. Conclusion: In this study, we propose a novel DTS system using orthogonal scanning technique. The results indicated that the image quality of our novel DTS system was superior compared to conventional DTS system. This makes our DTS system potentially useful in various on-line clinical applications.« less

  4. Numeral-Incorporating Roots in Numeral Systems: A Comparative Analysis of Two Sign Languages

    ERIC Educational Resources Information Center

    Fuentes, Mariana; Massone, Maria Ignacia; Fernandez-Viader, Maria del Pilar; Makotrinsky, Alejandro; Pulgarin, Francisca

    2010-01-01

    Numeral-incorporating roots in the numeral systems of Argentine Sign Language (LSA) and Catalan Sign Language (LSC), as well as the main features of the number systems of both languages, are described and compared. Informants discussed the use of numerals and roots in both languages (in most cases in natural contexts). Ten informants took part in…

  5. An Evaluation of Food Service Systems at Fort Myer, Bolling Air Force Base and Fort Benjamin Harrison

    DTIC Science & Technology

    1974-09-01

    A comparative evaluation of the food service operations at Fort Myer, Virginia; Bolling Air Force Base, Maryland; and Fort Benjamin Harrison, Indiana...was conducted. These three bases each represent different types of food service systems, which are respectively: contract provided food and labor...Operations Research and Systems Analysis Office had the responsibility for comparing the costs, nutritional aspects and consumer attitudes involved in these three different systems of food service .

  6. Linking environment-productivity trade-offs and correlated uncertainties: Greenhouse gas emissions and crop productivity in paddy rice production systems.

    PubMed

    Hayashi, Kiyotada; Nagumo, Yoshifumi; Domoto, Akiko

    2016-11-15

    In comparative life cycle assessments of agricultural production systems, analyses of both the trade-offs between environmental impacts and crop productivity and of the uncertainties specific to agriculture such as fluctuations in greenhouse gas (GHG) emissions and crop yields are crucial. However, these two issues are usually analyzed separately. In this paper, we present a framework to link trade-off and uncertainty analyses; correlated uncertainties are integrated into environment-productivity trade-off analyses. We compared three rice production systems in Japan: a system using a pelletized, nitrogen-concentrated organic fertilizer made from poultry manure using closed-air composting techniques (high-N system), a system using a conventional organic fertilizer made from poultry manure using open-air composting techniques (low-N system), and a system using a chemical compound fertilizer (conventional system). We focused on two important sources of uncertainties in paddy rice cultivation-methane emissions from paddy fields and crop yields. We found trade-offs between the conventional and high-N systems and the low-N system and the existence of positively correlated uncertainties in the conventional and high-N systems. We concluded that our framework is effective in recommending the high-N system compared with the low-N system, although the performance of the former is almost the same as the conventional system. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. AFB/open cycle gas turbine conceptual design study

    NASA Technical Reports Server (NTRS)

    Dickinson, T. W.; Tashjian, R.

    1983-01-01

    Applications of coal fired atmospheric fluidized bed gas turbine systems in industrial cogeneration are identified. Based on site-specific conceptual designs, the potential benefits of the AFB/gas turbine system were compared with an atmospheric fluidized design steam boiler/steam turbine system. The application of these cogeneration systems at four industrial plant sites is reviewed. A performance and benefit analysis was made along with a study of the representativeness of the sites both in regard to their own industry and compared to industry as a whole. A site was selected for the conceptual design, which included detailed site definition, AFB/gas turbine and AFB/steam turbine cogeneration system designs, detailed cost estimates, and comparative performance and benefit analysis. Market and benefit analyses identified the potential market penetration for the cogeneration technologies and quantified the potential benefits.

  8. AFB/open cycle gas turbine conceptual design study

    NASA Astrophysics Data System (ADS)

    Dickinson, T. W.; Tashjian, R.

    1983-09-01

    Applications of coal fired atmospheric fluidized bed gas turbine systems in industrial cogeneration are identified. Based on site-specific conceptual designs, the potential benefits of the AFB/gas turbine system were compared with an atmospheric fluidized design steam boiler/steam turbine system. The application of these cogeneration systems at four industrial plant sites is reviewed. A performance and benefit analysis was made along with a study of the representativeness of the sites both in regard to their own industry and compared to industry as a whole. A site was selected for the conceptual design, which included detailed site definition, AFB/gas turbine and AFB/steam turbine cogeneration system designs, detailed cost estimates, and comparative performance and benefit analysis. Market and benefit analyses identified the potential market penetration for the cogeneration technologies and quantified the potential benefits.

  9. Feasibility of standardized injury surveillance and reporting: a comparison of data from four Asian nations.

    PubMed

    Nakahara, S; Jayatilleke, A U; Ichikawa, M; Marasinghe, A; Kimura, A; Yoshida, K

    2008-04-01

    To address the increasing number of injuries in developing countries, the World Health Organization (WHO) encourages the establishment of hospital-based surveillance systems and systematic data collection. Although a computerized system is preferable in terms of efficiency, many developing countries have difficulty accessing the appropriate resources. To assess the possibility of comparing and sharing data among countries, and then to discuss the possibility of establishing an international data management system through the internet. A point-by-point comparison of data directories from injury surveillance systems in Thailand, Cambodia, Sri Lanka, and Japan was conducted using guidelines published by WHO as the standard. Thailand, Cambodia, and Sri Lanka used data items that are comparable to each other and to WHO guidelines, with few, readily amenable, differences. The Japanese system used quite different data items. Data comparability suggests the feasibility of a global data management system that can store data from various countries. Such a system, if made accessible over the internet, would benefit resource-constrained countries by providing them with a ready-made framework to implement a surveillance system at low cost.

  10. Neptune Orbiters Utilizing Solar and Radioisotope Electric Propulsion

    NASA Technical Reports Server (NTRS)

    Fiehler, Douglas I.; Oleson, Steven R.

    2004-01-01

    In certain cases, Radioisotope Electric Propulsion (REP), used in conjunction with other propulsion systems, could be used to reduce the trip times for outer planetary orbiter spacecraft. It also has the potential to improve the maneuverability and power capabilities of the spacecraft when the target body is reached as compared with non-electric propulsion spacecraft. Current missions under study baseline aerocapture systems to capture into a science orbit after a Solar Electric Propulsion (SEP) stage is jettisoned. Other options under study would use all REP transfers with small payloads. Compared to the SEP stage/Aerocapture scenario, adding REP to the science spacecraft as well as a chemical capture system can replace the aerocapture system but with a trip time penalty. Eliminating both the SEP stage and the aerocapture system and utilizing a slightly larger launch vehicle, Star 48 upper stage, and a combined REP/Chemical capture system, the trip time can nearly be matched while providing over a kilowatt of science power reused from the REP maneuver. A Neptune Orbiter mission is examined utilizing single propulsion systems and combinations of SEP, REP, and chemical systems to compare concepts.

  11. Comparative Evaluation of Biomass Power Generation Systems in China Using Hybrid Life Cycle Inventory Analysis

    PubMed Central

    Liu, Huacai; Yin, Xiuli; Wu, Chuangzhi

    2014-01-01

    There has been a rapid growth in using agricultural residues as an energy source to generate electricity in China. Biomass power generation (BPG) systems may vary significantly in technology, scale, and feedstock and consequently in their performances. A comparative evaluation of five typical BPG systems has been conducted in this study through a hybrid life cycle inventory (LCI) approach. Results show that requirements of fossil energy savings, and greenhouse gas (GHG) emission reductions, as well as emission reductions of SO2 and NOx, can be best met by the BPG systems. The cofiring systems were found to behave better than the biomass-only fired system and the biomass gasification systems in terms of energy savings and GHG emission reductions. Comparing with results of conventional process-base LCI, an important aspect to note is the significant contribution of infrastructure, equipment, and maintenance of the plant, which require the input of various types of materials, fuels, services, and the consequent GHG emissions. The results demonstrate characteristics and differences of BPG systems and help identify critical opportunities for biomass power development in China. PMID:25383383

  12. Coaxial Tubing Systems Increase Artificial Airway Resistance and Work of Breathing.

    PubMed

    Wenzel, Christin; Schumann, Stefan; Spaeth, Johannes

    2017-09-01

    Tubing systems are an essential component of the ventilation circuit, connecting the ventilator to the patient's airways. Coaxial tubing systems incorporate the inspiratory tube within the lumen of the expiratory one. We hypothesized that by design, these tubing systems increase resistance to air flow compared with conventional ones. We investigated the flow-dependent pressure gradient across coaxial, conventional disposable, and conventional reusable tubing systems from 3 different manufacturers. Additionally, the additional work of breathing and perception of resistance during breathing through the different devices were determined in 18 healthy volunteers. The pressure gradient across coaxial tubing systems was up to 6 times higher compared with conventional ones (1.90 ± 0.03 cm H 2 O vs 0.34 ± 0.01 cm H 2 O, P < .001) and was higher during expiration compared with inspiration ( P < .001). Additional work of breathing and perceived breathing resistance were highest in coaxial tubing systems, accordingly. Our findings suggest that the use of coaxial tubing systems should be carefully considered with respect to their increased resistance. Copyright © 2017 by Daedalus Enterprises.

  13. Design and evaluation of thermodynamic vent/screen baffle cryogenic storage system. [for space shuttles, space tugs, and spacelab

    NASA Technical Reports Server (NTRS)

    Cady, E. C.

    1975-01-01

    A comprehensive analytical program was performed to compare an integrated thermodynamic vent/screen baffle orbital cryogenic propellant storage and transfer system with other concepts. The screen systems were found to be 20% to 29% lighter in weight than a propulsively accelerated Tug-scale LH2/LO2 resupply module. The screen systems were compared with small-scale supercritical storage systems for the space shuttle fuel cell reactant and life support system fluid supply and were lighter by up to 556 kg (1225 lb) for the extended 30-day mission. When compared with high-pressure gas storage for the spacelab atmosphere supply, the screen system saved 79% of the inert system weight for the 30-day mission. An experimental program found that heat flux rates up to 9,450 watts/sq m (3,000 Btu/hr-sq ft) degraded the LH2 bubble point performance of eight screens by a maximum of 12.5%. No effects of helium pressurant, screen material, or LH2 superheat were observed.

  14. Comparative evaluation of biomass power generation systems in China using hybrid life cycle inventory analysis.

    PubMed

    Liu, Huacai; Yin, Xiuli; Wu, Chuangzhi

    2014-01-01

    There has been a rapid growth in using agricultural residues as an energy source to generate electricity in China. Biomass power generation (BPG) systems may vary significantly in technology, scale, and feedstock and consequently in their performances. A comparative evaluation of five typical BPG systems has been conducted in this study through a hybrid life cycle inventory (LCI) approach. Results show that requirements of fossil energy savings, and greenhouse gas (GHG) emission reductions, as well as emission reductions of SO2 and NOx, can be best met by the BPG systems. The cofiring systems were found to behave better than the biomass-only fired system and the biomass gasification systems in terms of energy savings and GHG emission reductions. Comparing with results of conventional process-base LCI, an important aspect to note is the significant contribution of infrastructure, equipment, and maintenance of the plant, which require the input of various types of materials, fuels, services, and the consequent GHG emissions. The results demonstrate characteristics and differences of BPG systems and help identify critical opportunities for biomass power development in China.

  15. Adhesive capability of total-etch, self-etch, and self-adhesive systems for fiber post cementation

    NASA Astrophysics Data System (ADS)

    Theodor, Y.; Koesmaningati, H.; Gita, F.

    2017-08-01

    The aim of this study was to analyze whether self-etch and self-adhesive systems are comparable to the total-etch system for fiber post cementation. This experimental laboratory study, which was approved by an ethics committee, was performed using 27 mandibular premolar teeth randomly divided into three groups. Fiber post cementation was done using three different adhesive systems. Specimens were prepared with a thickness of 5 mm, which was measured from the cervical to medial areas of the root, and stored for 24 h in saline solution at room temperature. A push-out test was performed using a universal testing machine (Shimidzu AG-5000E) with a crosshead speed of 0.5 mm/min. The results of one way ANOVA bivariate testing showed that the total-etch and self-etch systems have comparable adhesion capability (p<0.05) and that the self-adhesive system has the lowest adhesion capability (p>0.05). With easier application, the self-etch system has a comparable adhesion capability to the total-etch system.

  16. Feasibility of light-emitting diode uses for annular reactor inner-coated with TiO2 or nitrogen-doped TiO2 for control of dimethyl sulfide.

    PubMed

    Jo, Wan-Kuen; Eun, Sung-Soo; Shin, Seung-Ho

    2011-01-01

    Limited environmental pollutants have only been investigated for the feasibility of light-emitting diodes (LED) uses in photocatalytic decomposition (PD). The present study investigated the applicability of LEDs for annular photocatalytic reactors by comparing PD efficiencies of dimethyl sulfide (DMS), which has not been investigated with any LED-PD system, between photocatalytic systems utilizing conventional and various LED lamps with different wavelengths. A conventional 8 W UV/TiO(2) system exhibited a higher DMS PD efficiency as compared with UV-LED/TiO(2) system. Similarly, a conventional 8 W visible-lamp/N-enhanced TiO(2) (NET) system exhibited a higher PD efficiency as compared with six visible-LED/NET systems. However, the ratios of PD efficiency to the electric power consumption were rather high for the photocatalytic systems using UV- or visible-LED lamps, except for two LED lamps (yellow- and red-LED lamps), compared to the photocatalytic systems using conventional lamps. For the photocatalytic systems using LEDs, lower flow rates and input concentrations and shorter hydraulic diameters exhibited higher DMS PD efficiencies. An Fourier-transformation infrared analysis suggested no significant absorption of byproducts on the catalyst surface. Consequently, it was suggested that LEDs can still be energy-efficiently utilized as alternative light sources for the PD of DMS, under the operational conditions used in this study. © 2011 The Authors. Photochemistry and Photobiology © 2011 The American Society of Photobiology.

  17. A comparative study on the enhanced operation of a BFB and SFCW coupling process for domestic wastewater treatment

    NASA Astrophysics Data System (ADS)

    Lingwei, Kong; Lu, Wang; Rongwu, Mei; Yingyu, Tan; Yu, Zhang; Yan, Gao; Jianing, Sun; Ya, Li

    2018-05-01

    In this study, a new coupling process system of BFB (biological filter bed) and SFCW (subsurface-flow constructed wetland) based on the auto-ventilation network was proposed, and the comparative pollutant removal efficiency of the pilot test coupling system with different substrates configurations were investigated. The study found that: the influent concentration of the system fluctuated greatly and effluent concentration of the comparison system (b) was 20.22 ± 13.37 mg/L, 2.70 ± 2.49 mg/L, 4.40 ± 3.05 mg/L and 1.09 ± 0.62 mg/L, respectively. The comparison system (b) had better removal rates than that of the original system (a), which was 81.30 %, 90.28 %, 88.57 % and 75.36 % for CODcr, NH4 +-N, TN and TP, respectively. The removal of the above main water indexes of the comparison system (b) promoted to 4.20 %, 9.20 %, 7.66 % and 13.61 % respectively when compared to the original system (a), which showed that the optimized configuration of various kinds of substrates was significant and was more beneficial to the degradation and removal of pollutants. The adsorption and interception function of substrates in the constructed wetland was the main way of phosphorus removal. The function of auto-ventilation ensured the amount of DO in the coupling system, making the phosphorus removal was less affected comparing to structure of traditional wetland.

  18. Comparison of the AJCC, MSTS, and Modified Spanier Systems for Clinical and Pathologic Staging of Osteosarcoma.

    PubMed

    Cates, Justin M M

    2017-03-01

    The prognostic performance of the 2 most commonly used staging systems for skeletal sarcoma (the American Joint Committee on Cancer [AJCC] and Musculoskeletal Tumor Society [MSTS] systems) have never been compared analytically. Another staging system originally proposed by Spanier has not yet been validated. Given the recent release of the 8th edition of the AJCC Cancer Staging Manual, this study was designed to directly compare these anatomic staging systems in a series of 153 high-grade, intramedullary osteosarcomas. Kaplan-Meier curves were plotted and pairwise comparisons between each stage category were performed. Predictive accuracy of each staging system for determining 5-year disease-free survival was evaluated by comparing areas under receiver-operating characteristic curves generated from logistic regression analysis. Multiple concordance indices were calculated using bootstrapping methods (200 replications). ρk and R were estimated as measures of the variation in survival outcomes explained by the regression models. The AJCC, MSTS, and a modified version of the Spanier staging systems showed similar discriminatory abilities and no significant differences in the levels of contrast between different tumor stages across staging systems. Addition of T-category information from each staging system contributed significant prognostic information compared with a Cox proportional hazard regression model consisting only of the presence or absence of metastatic disease as a measure of disease extent. Concordance indices and predictive accuracy for 5-year disease-free survival were not significantly different among the different staging systems either. Similar findings were observed after accounting for other important prognostic variables. Additional studies are necessary to determine performance parameters of each staging system for other types of skeletal sarcoma. Prognostic performance of osteosarcoma staging systems would also be improved by incorporating nonanatomic prognostic variables into staging algorithms.

  19. Children and Adolescents with Autism Spectrum Disorders Compared to Typically Developing Controls on the Behavioral Assessment System for Children, Second Edition (BASC-2)

    ERIC Educational Resources Information Center

    Mahan, Sara; Matson, Johnny L.

    2011-01-01

    As the "Behavioral Assessment System for Children, Second Edition" ("BASC-2") is often used to aid in diagnosis it is important to discern how children and adolescents with Autism Spectrum Disorder (ASD) score on the "BASC-2" compared to typically developing controls. This study compared scores of typically developing…

  20. Comparative health and safety assessment of the SPS and alternative electrical generation systems

    NASA Astrophysics Data System (ADS)

    Habegger, L. J.; Gasper, J. R.; Brown, C. D.

    1980-07-01

    A comparative analysis of health and safety risks is presented for the Satellite Power System and five alternative baseload electrical generation systems: a low-Btu coal gasification system with an open-cycle gas turbine combined with a steam topping cycle; a light water fission reactor system without fuel reprocessing; a liquid metal fast breeder fission reactor system; a central station terrestrial photovoltaic system; and a first generation fusion system with magnetic confinement. For comparison, risk from a decentralized roof-top photovoltaic system with battery storage is also evaluated. Quantified estimates of public and occupational risks within ranges of uncertainty were developed for each phase of the energy system. The potential significance of related major health and safety issues that remain unquantitied are also discussed.

  1. Comparative health and safety assessment of the SPS and alternative electrical generation systems

    NASA Technical Reports Server (NTRS)

    Habegger, L. J.; Gasper, J. R.; Brown, C. D.

    1980-01-01

    A comparative analysis of health and safety risks is presented for the Satellite Power System and five alternative baseload electrical generation systems: a low-Btu coal gasification system with an open-cycle gas turbine combined with a steam topping cycle; a light water fission reactor system without fuel reprocessing; a liquid metal fast breeder fission reactor system; a central station terrestrial photovoltaic system; and a first generation fusion system with magnetic confinement. For comparison, risk from a decentralized roof-top photovoltaic system with battery storage is also evaluated. Quantified estimates of public and occupational risks within ranges of uncertainty were developed for each phase of the energy system. The potential significance of related major health and safety issues that remain unquantitied are also discussed.

  2. Intrathecal Drug Delivery Systems for Noncancer Pain: A Health Technology Assessment.

    PubMed

    2016-01-01

    Intrathecal drug delivery systems can be used to manage refractory or persistent chronic nonmalignant (noncancer) pain. We investigated the benefits, harms, cost-effectiveness, and budget impact of these systems compared with current standards of care for adult patients with chronic pain owing to nonmalignant conditions. We searched Ovid MEDLINE, Ovid Embase, the Cochrane Library, and the National Health Service's Economic Evaluation Database and Tufts Cost-Effectiveness Analysis Registry from January 1994 to April 2014 for evidence of effectiveness, harms, and cost-effectiveness. We used existing systematic reviews that had employed reliable search and screen methods and also searched for studies published after the search date reported in the latest systematic review to identify studies. Two reviewers screened records and assessed study validity. We found comparative evidence of effectiveness and harms in one cohort study at high risk of bias (≥ 3-year follow-up, N = 130). Four economic evaluations of low to very low quality were also included. Compared with oral opioid analgesia alone or a program of analgesia plus rehabilitation, intrathecal drug delivery systems significantly reduced pain (27% additional improvement) and morphine consumption. Despite these reductions, intrathecal drug delivery systems were not superior in patient-reported well-being or quality of life. There is no evidence of superiority of intrathecal drug delivery systems over oral opioids in global pain improvement and global treatment satisfaction. Comparative evidence of harms was not found. Cost-effectiveness evidence is of insufficient quality to assess the appropriateness of funding intrathecal drug delivery systems. Evidence comparing intrathecal drug delivery systems with standard care was of very low quality. Current evidence does not establish (or rule out) superiority or cost-effectiveness of intrathecal drug delivery systems for managing chronic refractory nonmalignant pain. The budget impact of funding intrathecal drug delivery systems would be between $1.5 and $5.0 million per year.

  3. Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System

    PubMed Central

    Koenen, Paola; Schneider, Marco M.; Fröhlich, Matthias; Driessen, Arne; Bouillon, Bertil; Bäthis, Holger

    2016-01-01

    Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective analysis of 40 patients was performed, who underwent CAS TKA using the iPod-based navigation system DASH. Pre- and postoperative axial alignment were measured on standardized radiographs by two independent observers. These data were compared with the navigation data. Furthermore, interobserver reliability was measured. The duration of surgery was monitored. The mean difference between the preoperative mechanical axis by X-ray and the first intraoperatively measured limb axis by the navigation system was 2.4°. The postoperative X-rays showed a mean difference of 1.3° compared to the final navigation measurement. According to radiographic measurements, 88% of arthroplasties had a postoperative limb axis within ±3°. The mean additional time needed for navigation was 5 minutes. We could prove very good precision for the DASH system, which is comparable to established navigation devices with only negligible expenditure of time compared to conventional TKA. PMID:27313898

  4. International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wohlgemuth, J.; Kurtz, S.

    The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests aremore » being developed for each of the selected climate zones.« less

  5. Comparative study of metallic silicide-germanide orthorhombic MnP systems.

    PubMed

    Connétable, Damien; Thomas, Olivier

    2013-09-04

    We present a comparative study of the structural, energetic, electronic and elastic properties of MX type MnP systems (where X=Si or Ge, and M=Pt, Pd or Ni) using first-principles calculations. The optimized ground state properties of these systems are in excellent agreement with the experimental values. A detailed comparative study of the elastic properties of polycrystalline structures is also presented. We analyze the relationship between the composition and the properties of the systems. Finally, we present the properties of NiSi1-xGex alloys. We show that these properties depend linearly on the Ge content of the alloy. This work has important consequences for semiconductor devices in which silicides, germanides and alloys thereof are used as contact materials.

  6. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    PubMed

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  7. Antibacterial, anti-inflammatory, and bone-regenerative dual-drug-loaded calcium phosphate nanocarriers-in vitro and in vivo studies.

    PubMed

    Madhumathi, K; Rubaiya, Y; Doble, Mukesh; Venkateswari, R; Sampath Kumar, T S

    2018-05-01

    A dual local drug delivery system (DDS) composed of calcium phosphate bioceramic nanocarriers aimed at treating the antibacterial, anti-inflammatory, and bone-regenerative aspects of periodontitis has been developed. Calcium-deficient hydroxyapatite (CDHA, Ca/P = 1.61) and tricalcium phosphate (β-TCP) were prepared by microwave-accelerated wet chemical synthesis method. The phase purity of the nanocarriers was confirmed by x-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT-IR), while the transmission electron microscopy (TEM) confirmed their nanosized morphology. CDHA was selected as carrier for the antibiotic (tetracycline) while TCP was chosen as the anti-inflammatory drug (ibuprofen) carrier. Combined drug release profile was studied in vitro from CDHA/TCP (CTP) system and compared with a HA/TCP (BCP) biphasic system. The tetracycline and ibuprofen release rate was 71 and 23% from CTP system as compared to 63 and 20% from BCP system. CTP system also showed a more controlled drug release profile compared to BCP system. Modeling of drug release kinetics from CTP system indicated that the release follows Higuchi model with a non-typical Fickian diffusion profile. In vitro biological studies showed the CTP system to be biocompatible with significant antibacterial and anti-inflammatory activity. In vivo implantation studies on rat cranial defects showed greater bone healing and new bone formation in the drug-loaded CTP system compared to control (no carrier) at the end of 12 weeks. The in vitro and in vivo results suggest that the combined drug delivery platform can provide a comprehensive management for all bone infections requiring multi-drug therapy.

  8. Usability analysis of industrial cooking equipment.

    PubMed

    Calado, Alexana Vilar Soares; Soares, Marcelo Márcio

    2012-01-01

    This paper refers to the comparative study of the equipment used for cooking in commercial of kitchens restaurants that use the system of traditional cooking and those ones which use the system called smart cooking (combination oven). The study investigates the usability issues concerning to the two systems, analyzing comparatively the aspects related to anthropometry, dimensional variables, the use of the product and also the product safety, as well as issues of information related to operation of the new concepts of cooking in intelligent systems.

  9. Dichotomous versus semi-quantitative scoring of ultrasound joint inflammation in rheumatoid arthritis using novel individualized joint selection methods.

    PubMed

    Tan, York Kiat; Allen, John C; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Thumboo, Julian

    2017-05-01

    The aim of the study is to compare the responsiveness of two joint inflammation scoring systems (dichotomous scoring (DS) versus semi-quantitative scoring (SQS)) using novel individualized ultrasound joint selection methods and existing ultrasound joint selection methods. Responsiveness measured by the standardized response means (SRMs) using the DS and the SQS system (for both the novel and existing ultrasound joint selection methods) was derived using the baseline and the 3-month total inflammatory scores from 20 rheumatoid arthritis patients. The relative SRM gain ratios (SRM-Gains) for both scoring system (DS and SQS) comparing the novel to the existing methods were computed. Both scoring systems (DS and SQS) demonstrated substantial SRM-Gains (ranged from 3.31 to 5.67 for the DS system and ranged from 1.82 to 3.26 for the SQS system). The SRMs using the novel methods ranged from 0.94 to 1.36 for the DS system and ranged from 0.89 to 1.11 for the SQS system. The SRMs using the existing methods ranged from 0.24 to 0.32 for the DS system and ranged from 0.34 to 0.49 for the SQS system. The DS system appears to achieve high responsiveness comparable to SQS for the novel individualized ultrasound joint selection methods.

  10. An Analysis of the Cost Effectiveness of Various Electronic Alternatives for Delivering Distance Education Compared to the Travel Costs for Live Instruction.

    ERIC Educational Resources Information Center

    Caffarella, Edward; And Others

    The feasibility and relative costs of four telecommunication systems for delivering university courses to distant locations in Colorado were compared. The four systems were compressed video, vertical blanking interval video, satellite video, and audiographic systems. Actual costs to install and operate each for a 5-year period were determined,…

  11. Individual stem value recovery of modified and conventional tree-length systems in the southeastern United States

    Treesearch

    Amanda H. Lang; Shawn A. Baker; W. Dale Greene; Glen E. Murphy

    2010-01-01

    We compared value recovery of a modified treelength (MTL) logging system that measures product diameter and length using a Waratah 626 harvester head to that of a treelength (TL) system that estimates dimensions. A field test compared the actual value cut to the maximum potential value suggested by the log bucking optimization program Assessment of Value by Individual...

  12. Autologous Fat Grafting to the Breast Using REVOLVE System to Reduce Clinical Costs.

    PubMed

    Brzezienski, Mark A; Jarrell, John A

    2016-09-01

    With the increasing popularity of fat grafting over the past decade, the techniques for harvest, processing and preparation, and transfer of the fat cells have evolved to improve efficiency and consistency. The REVOLVE System is a fat processing device used in autologous fat grafting which eliminates much of the specialized equipment as well as the labor intensive and time consuming efforts of the original Coleman technique of fat processing. This retrospective study evaluates the economics of fat grafting, comparing traditional Coleman processing to the REVOLVE System. From June 2013 through December 2013, 88 fat grafting cases by a single-surgeon were reviewed. Timed procedures using either the REVOLVE System or Coleman technique were extracted from the group. Data including fat grafting procedure time, harvested volume, harvest and recipient sites, and concurrent procedures were gathered. Cost and utilization assessments were performed comparing the economics between the groups using standard values of operating room costs provided by the study hospital. Thirty-seven patients with timed procedures were identified, 13 of which were Coleman technique patients and twenty-four (24) were REVOLVE System patients. The average rate of fat transfer was 1.77 mL/minute for the Coleman technique and 4.69 mL/minute for the REVOLVE System, which was a statistically significant difference (P < 0.0001) between the 2 groups. Cost analysis comparing the REVOLVE System and Coleman techniques demonstrates a dramatic divergence in the price per mL of transferred fat at 75 mL when using the previously calculated rates for each group. This single surgeon's experience with the REVOLVE System for fat processing establishes economic support for its use in specific high-volume fat grafting cases. Cost analysis comparing the REVOLVE System and Coleman techniques suggests that in cases of planned fat transfer of 75 mL or more, using the REVOLVE System for fat processing is more economically beneficial. This study may serve as a guide to plastic surgeons in deciding which cases might be appropriate for the use of the REVOLVE System and is the first report comparing economics of fat grafting with the traditional Coleman technique and the REVOLVE System.

  13. Technical and economic evaluation of a Brayton-Rankine combined cycle solar-thermal power plant

    NASA Astrophysics Data System (ADS)

    Wright, J. D.; Copeland, R. J.

    1981-05-01

    An assessment of gas-liquid direct-contact heat exchange and of a new storage-coupled system was conducted. Both technical and economic issues are evaluated. Specifically, the storage-coupled combined cycle is compared with a molten salt system. The open Brayton cycle system is used as a topping cycle, and the reject heat powers the molten salt/Rankine system. In this study the molten salt system is left unmodified, the Brayton cycle is integrated on top of a Marietta description of an existing molten salt plant. This compares a nonoptimized combined cycle with an optimized molten salt system.

  14. Moderate temperature control technology for a lunar base

    NASA Technical Reports Server (NTRS)

    Swanson, Theodore D.; Sridhar, K. R.; Gottmann, Matthias

    1993-01-01

    A parametric analysis is performed to compare different heat pump based thermal control systems for a Lunar Base. Rankine cycle and absorption cycle heat pumps are compared and optimized for a 100 kW cooling load. Variables include the use or lack of an interface heat exchanger, and different operating fluids. Optimization of system mass to radiator rejection temperature is performed. The results indicate a relatively small sensitivity of Rankine cycle system mass to these variables, with optimized system masses of about 6000 kg for the 100 kW thermal load. It is quantitaively demonstrated that absorption based systems are not mass competitive with Rankine systems.

  15. Serial completely stirred tank reactors for improving biogas production and substance degradation during anaerobic digestion of corn stover.

    PubMed

    Li, YuQian; Liu, ChunMei; Wachemo, Akiber Chufo; Yuan, HaiRong; Zou, DeXun; Liu, YanPing; Li, XiuJin

    2017-07-01

    Several completely stirred tank reactors (CSTR) connected in series for anaerobic digestion of corn stover were investigated in laboratory scale. Serial anaerobic digestion systems operated at a total HRT of 40days, and distribution of HRT are 10+30days (HRT10+30d), 20+20days (HRT20+20d), and 30+10days (HRT30+10d) were compared to a conventional one-step CSTR at the same HRT of 40d. The results showed that in HRT10+30d serial system, the process became very unstable at organic load of 50gTS·L -1 . The HRT20+20d and HRT30+10d serial systems improved methane production by 8.3-14.6% compared to the one-step system in all loads of 50, 70, 90gTS·L -1 . The conversion rates of total solid, cellulose, and hemicellulose were increased in serial anaerobic digestion systems compared to single system. The serial systems showed more stable process performance in high organic load. HRT30+10d system showed the best biogas production and conversions among all systems. Copyright © 2017. Published by Elsevier Ltd.

  16. Comparative Actions of Barbiturates Studied by Pollen Grain Germination.

    ERIC Educational Resources Information Center

    Kordan, Herbert A.; Mumford, Pauline M.

    1979-01-01

    Describes a simple experimental system whereby the comparative actions of long, medium, and short-acting barbiturates can be demonstrated in a relatively short period of time under optical microscopy using pollen grains as the biological test or assay system. (Author/HM)

  17. Comparison of diagnosis of early retinal lesions of diabetic retinopathy between a computer system and human experts.

    PubMed

    Lee, S C; Lee, E T; Kingsley, R M; Wang, Y; Russell, D; Klein, R; Warn, A

    2001-04-01

    To investigate whether a computer vision system is comparable with humans in detecting early retinal lesions of diabetic retinopathy using color fundus photographs. A computer system has been developed using image processing and pattern recognition techniques to detect early lesions of diabetic retinopathy (hemorrhages and microaneurysms, hard exudates, and cotton-wool spots). Color fundus photographs obtained from American Indians in Oklahoma were used in developing and testing the system. A set of 369 color fundus slides were used to train the computer system using 3 diagnostic categories: lesions present, questionable, or absent (Y/Q/N). A different set of 428 slides were used to test and evaluate the system, and its diagnostic results were compared with those of 2 human experts-the grader at the University of Wisconsin Fundus Photograph Reading Center (Madison) and a general ophthalmologist. The experiments included comparisons using 3 (Y/Q/N) and 2 diagnostic categories (Y/N) (questionable cases excluded in the latter). In the training phase, the agreement rates, sensitivity, and specificity in detecting the 3 lesions between the retinal specialist and the computer system were all above 90%. The kappa statistics were high (0.75-0.97), indicating excellent agreement between the specialist and the computer system. In the testing phase, the results obtained between the computer system and human experts were consistent with those of the training phase, and they were comparable with those between the human experts. The performance of the computer vision system in diagnosing early retinal lesions was comparable with that of human experts. Therefore, this mobile, electronically easily accessible, and noninvasive computer system, could become a mass screening tool and a clinical aid in diagnosing early lesions of diabetic retinopathy.

  18. A Comparison of Zero Mean Strain Rotating Beam Fatigue Test Methods for Nitinol Wire

    NASA Astrophysics Data System (ADS)

    Norwich, Dennis W.

    2014-07-01

    Zero mean strain rotating beam fatigue testing has become the standard for comparing the fatigue properties of Nitinol wire. Most commercially available equipment consists of either a two-chuck or a chuck and bushing system, where the wire length and center-to-center axis distance determine the maximum strain on the wire. For the two-chuck system, the samples are constrained at either end of the wire, and both chucks are driven at the same speed. For the chuck and bushing system, the sample is constrained at one end in a chuck and rides freely in a bushing at the other end. These equivalent systems will both be herein referred to as Chuck-to-Chuck systems. An alternate system uses a machined test block with a specific radius to guide the wire at a known strain during testing. In either system, the test parts can be immersed in a temperature-controlled fluid bath to eliminate any heating effect created in the specimen due to dissipative processes during cyclic loading (cyclic stress induced the formation of martensite) Wagner et al. ( Mater. Sci. Eng. A, 378, p 105-109, 1). This study will compare the results of the same starting material tested with each system to determine if the test system differences affect the final results. The advantages and disadvantages of each system will be highlighted and compared. The factors compared will include ease of setup, operator skill level required, consistency of strain measurement, equipment test limits, and data recovery and analysis. Also, the effect of test speed on the test results for each system will be investigated.

  19. Physical evaluation of a needle photostimulable phosphor based CR mammography system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, Nicholas W.; Lemmens, Kim; Bosmans, Hilde

    2012-02-15

    Purpose: Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. Methods: Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose,more » for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. Results: MTF at 5 mm{sup -1} was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement ({approx}20%) over the two powder CR systems but remained 50% lower than the result at 5 mm{sup -1} for the a-Se detector ({approx}0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at {approx}100 {mu}Gy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm{sup -1}) was 0.19 for the needle CR plates, a factor of approximately 3 greater than for the powder CR plates. At 28 kV W/Rh, 2 mm Al, peak DQE for the needle CR system was 0.45 against a value of 0.50 for the a-Se detector. The needle CR detector reached the Acceptable limit for 0.1 mm details in the European Guidelines at a mean glandular dose (MGD) of approximately 1.31 mGy imaged at 28 kV Mo/Rh, compared to figures of 2.19 and 1.43 mGy for the single sided and dual sided readout powder CR systems. The a-Se detector could reach the limit at 0.65 mGy using a 28 kV W/Rh spectrum, while the needle CR system required 1.09 mGy for the same spectrum. Conclusions: Imaging performance for the needle CR phosphor technology, characterized using MTF and DQE and threshold gold thickness demonstrated a clear improvement compared to both single and dual sided reading powder phosphor based CR systems.« less

  20. Comparison of the 7(th) and proposed 8(th) editions of the AJCC/UICC TNM staging system for non-small cell lung cancer undergoing radical surgery.

    PubMed

    Jin, Ying; Chen, Ming; Yu, Xinmin

    2016-09-19

    The present study aims to compare the 7(th) and the proposed 8(th) edition of the AJCC/UICC TNM staging system for NSCLC in a cohort of patients from a single institution. A total of 408 patients with NSCLC who underwent radical surgery were analyzed retrospectively. Survivals were analyzed using the Kaplan -Meier method and were compared using the log-rank test. Multivariate analysis was performed by the Cox proportional hazard model. The Akaike information criterion (AIC) and C-index were applied to compare the two prognostic systems with different numbers of stages. The 7(th) AJCC T categories, the proposed 8(th) AJCC T categories, N categories, visceral pleural invasion, and vessel invasion were found to have statistically significant associations with disease-free survival (DFS) on univariate analysis. In the 7(th) edition staging system as well as in the proposed 8(th) edition, T categories, N categories, and pleural invasion were independent factors for DFS on multivariate analysis. The AIC value was smaller for the 8(th) edition compared to the 7(th) edition staging system. The C-index value was larger for the 8(th) edition compared to the 7(th) edition staging system. Based on the data from our single center, the proposed 8(th) AJCC T classification seems to be superior to the 7(th) AJCC T classification in terms of DFS for patients with NSCLC underwent radical surgery.

  1. Responsiveness of the health insurance and private systems in Alexandria, Egypt.

    PubMed

    Mosallam, Rasha A; Aly, Mahmoud M; Moharram, Ahmed M

    2013-04-01

    Responsiveness to patients is a key indicator for measuring the health system performance with respect to nonhealth aspects. This study aimed to compare responsiveness of the Health Insurance Organization (HIO) with the private healthcare system and also to assess the importance of the different responsiveness domains according to the study population's perspective. Patients attending both inpatient and outpatient settings of both organizations were interviewed (200 outpatients and 200 inpatients from each selected hospital) using the WHO questionnaire. The questionnaire elicits the ratings of the respondents on their experiences with the healthcare system over the past 12 months in terms of responsiveness domains, respondents' inability to access medical care because of financial barriers, and their ranking of the relative importance of responsiveness domains. Almost twice the number of HIO participants reported poor responsiveness compared with the private organization participants (27.8 vs. 56.8%, respectively). The outpatient setting scored much favorably compared with the inpatient setting at the HIO (52.3% of respondents reported poor responsiveness in the outpatient setting compared with 76.3% in the inpatient setting); however, they were comparable in the private setting. Communication, prompt attention, and dignity were the domains most frequently rated as the most important (36.0, 32.0, and 14.7%, respectively). The type of organization (HIO vs. private organization) and setting of care (inpatient vs. outpatient) were significant predictors of responsiveness score (P<0.001). The overall rating of the patients on responsiveness of the HIO system is low, especially when compared with the private sector. The results emphasize the importance of establishment of systems for monitoring the performance of the providers and discontinuation of the services for the nonperformers.

  2. Automatic Exposure Control Systems Designed to Maintain Constant Image Noise: Effects on Computed Tomography Dose and Noise Relative to Clinically Accepted Technique Charts

    PubMed Central

    Favazza, Christopher P.; Yu, Lifeng; Leng, Shuai; Kofler, James M.; McCollough, Cynthia H.

    2015-01-01

    Objective To compare computed tomography dose and noise arising from use of an automatic exposure control (AEC) system designed to maintain constant image noise as patient size varies with clinically accepted technique charts and AEC systems designed to vary image noise. Materials and Methods A model was developed to describe tube current modulation as a function of patient thickness. Relative dose and noise values were calculated as patient width varied for AEC settings designed to yield constant or variable noise levels and were compared to empirically derived values used by our clinical practice. Phantom experiments were performed in which tube current was measured as a function of thickness using a constant-noise-based AEC system and the results were compared with clinical technique charts. Results For 12-, 20-, 28-, 44-, and 50-cm patient widths, the requirement of constant noise across patient size yielded relative doses of 5%, 14%, 38%, 260%, and 549% and relative noises of 435%, 267%, 163%, 61%, and 42%, respectively, as compared with our clinically used technique chart settings at each respective width. Experimental measurements showed that a constant noise–based AEC system yielded 175% relative noise for a 30-cm phantom and 206% relative dose for a 40-cm phantom compared with our clinical technique chart. Conclusions Automatic exposure control systems that prescribe constant noise as patient size varies can yield excessive noise in small patients and excessive dose in obese patients compared with clinically accepted technique charts. Use of noise-level technique charts and tube current limits can mitigate these effects. PMID:25938214

  3. Comparing the quality of antidepressant pharmacotherapy in the Department of Veterans Affairs and the private sector.

    PubMed

    Busch, Susan H; Leslie, Douglas L; Rosenheck, Robert A

    2004-12-01

    Comparing quality of care between large health care systems is important for health systems management. This study compared measures of the quality of pharmacotherapy for patients with major depression across a sample of patients from the Department of Veterans Affairs (VA) and the private sector. In this observational study, all patients who were given a new prescription for an antidepressant and a diagnosis of major depression in the VA during fiscal year 2000 were identified by using administrative data (N=27,713). In the private sector, a similar sample of patients were identified by using Medstat's MarketScan database (N=4,852). For both groups, measures of the quality of antidepressant pharmacotherapy were constructed. These measures were compared across the two groups by using logistic regression models. Controls for age, gender, comorbid disorders, and initial antidepressant drug prescribed were included in some models. Although the populations had different demographic and clinical characteristics, differences in the quality measures between the two systems were few, with the VA slightly outperforming the private sector in the prescription of antidepressants during the acute phase of treatment, the first 84 days (84.7 compared with 81 percent) and during the maintenance phase of treatment, the first 181 days (53.9 compared with 50.9 percent). Patient characteristics that were associated with quality measures included being older, being female, and having a comorbid diagnosis of substance use disorder, bipolar disorder, or anxiety or adjustment disorder. Both systems had relatively high rates of adherence to pharmacotherapy guidelines. Even though the populations in the two systems were different, adjusting the analyses for clinical characteristics did little to change the measured differences between the two systems.

  4. Aircraft Engine On-Line Diagnostics Through Dual-Channel Sensor Measurements: Development of an Enhanced System

    NASA Technical Reports Server (NTRS)

    Kobayashi, Takahisa; Simon, Donald L.

    2008-01-01

    In this paper, an enhanced on-line diagnostic system which utilizes dual-channel sensor measurements is developed for the aircraft engine application. The enhanced system is composed of a nonlinear on-board engine model (NOBEM), the hybrid Kalman filter (HKF) algorithm, and fault detection and isolation (FDI) logic. The NOBEM provides the analytical third channel against which the dual-channel measurements are compared. The NOBEM is further utilized as part of the HKF algorithm which estimates measured engine parameters. Engine parameters obtained from the dual-channel measurements, the NOBEM, and the HKF are compared against each other. When the discrepancy among the signals exceeds a tolerance level, the FDI logic determines the cause of discrepancy. Through this approach, the enhanced system achieves the following objectives: 1) anomaly detection, 2) component fault detection, and 3) sensor fault detection and isolation. The performance of the enhanced system is evaluated in a simulation environment using faults in sensors and components, and it is compared to an existing baseline system.

  5. Sensor fusion display evaluation using information integration models in enhanced/synthetic vision applications

    NASA Technical Reports Server (NTRS)

    Foyle, David C.

    1993-01-01

    Based on existing integration models in the psychological literature, an evaluation framework is developed to assess sensor fusion displays as might be implemented in an enhanced/synthetic vision system. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The pilot's performance with the sensor fusion image is compared to models' predictions based on the pilot's performance when viewing the original component sensor images prior to fusion. This allows for the determination as to when a sensor fusion system leads to: poorer performance than one of the original sensor displays, clearly an undesirable system in which the fused sensor system causes some distortion or interference; better performance than with either single sensor system alone, but at a sub-optimal level compared to model predictions; optimal performance compared to model predictions; or, super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays.

  6. Evaluation of radiation exposure with Tru-Align intraoral rectangular collimation system using OSL dosimeters.

    PubMed

    Goren, Arthur D; Bonvento, Michael J; Fernandez, Thomas J; Abramovitch, Kenneth; Zhang, Wenjian; Roe, Nadine; Seltzer, Jared; Steinberg, Mitchell; Colosi, Dan C

    2011-03-01

    A pilot study to compare radiation exposure with the Tru-Align rectangular collimation system to round collimation exposures was undertaken. Radiation exposure at various points within the cross sections of the collimators and entrance, intraoral and exit dose measurements were measured using InLight OSL dosimeters. Overall dose reduction with the use of the rectangular collimation system was estimated by taking into account the ratios of collimator openings and the average radiation exposure at the measurement points. Use of the Tru-Align system resulted in an average radiation exposure within the perimeter of the projected outline of the rectangular collimator of 36.1 mR, compared to 148.5 mR with the round collimator. Our calculations indicate a dose reduction by a factor of approximately 3.2 in the case of the Tru-Align system compared to round collimation. The Tru-Align system was easy to use, but in some situations failed to allow Xray coverage of the entire surface of the image receptor, leading to cone cuts.

  7. Methods for comparative evaluation of propulsion system designs for supersonic aircraft

    NASA Technical Reports Server (NTRS)

    Tyson, R. M.; Mairs, R. Y.; Halferty, F. D., Jr.; Moore, B. E.; Chaloff, D.; Knudsen, A. W.

    1976-01-01

    The propulsion system comparative evaluation study was conducted to define a rapid, approximate method for evaluating the effects of propulsion system changes for an advanced supersonic cruise airplane, and to verify the approximate method by comparing its mission performance results with those from a more detailed analysis. A table look up computer program was developed to determine nacelle drag increments for a range of parametric nacelle shapes and sizes. Aircraft sensitivities to propulsion parameters were defined. Nacelle shapes, installed weights, and installed performance was determined for four study engines selected from the NASA supersonic cruise aircraft research (SCAR) engine studies program. Both rapid evaluation method (using sensitivities) and traditional preliminary design methods were then used to assess the four engines. The method was found to compare well with the more detailed analyses.

  8. Woodstove Emission Sampling Methods Comparability Analysis and In-situ Evaluation of New Technology Woodstoves.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simons, Carl A.

    1988-06-01

    One major objective of this study was to compare several woodstove particulate emission sampling methods under laboratory and in-situ conditions. The laboratory work compared the EPA Method 5H, EPA Method 5G, and OMNI Automated Woodstove Emission Sampler (AWES)/Data LOG'r particulate emission sampling systems. A second major objective of the study was to evaluate the performance of two integral catalytic, two low emission non-catalytic, and two conventional technology woodstoves under in-situ conditions with AWES/Data LOG'r system. The AWES/Data LOG'r and EPA Method 5G sampling systems were also compared in an in-situ test on one of the integral catalytic woodstove models. 7more » figs., 12 tabs.« less

  9. A Comparative Study on the Environmental Impact of CO2 Supermarket Refrigeration Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beshr, Mohamed; Aute, Vikrant; Sharma, Vishaldeep

    Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Accordingly, the interest in using natural refrigerants, such as carbon dioxide (CO2), and new refrigerant blends with low GWP in such systems is increasing. In this paper, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of three supermarket refrigeration systems. These systems include a transcritical CO2 booster system, a cascade CO2/N-40 system, and a baseline R-404A multiplex direct expansion system. The study is performed for cities representing different climates within the USA using EnergyPlusmore » to simulate the systems' hourly performance. Finally, a parametric analysis is performed to study the impact of annual leak rate on the systems' LCCP.« less

  10. Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Geon; Khan, Umer Amir; Lim, Sung-Woo; Shin, Woo-ju; Seo, In-Jin; Lee, Bang-Wook

    2015-11-01

    High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid.

  11. Cost-effectiveness analysis of a system-based approach for managing neonatal jaundice and preventing kernicterus in Ontario.

    PubMed

    Xie, Bin; da Silva, Orlando; Zaric, Greg

    2012-01-01

    To evaluate the incremental cost-effectiveness of a system-based approach for the management of neonatal jaundice and the prevention of kernicterus in term and late-preterm (≥35 weeks) infants, compared with the traditional practice based on visual inspection and selected bilirubin testing. Two hypothetical cohorts of 150,000 term and late-preterm neonates were used to compare the costs and outcomes associated with the use of a system-based or traditional practice approach. Data for the evaluation were obtained from the case costing centre at a large teaching hospital in Ontario, supplemented by data from the literature. The per child cost for the system-based approach cohort was $176, compared with $173 in the traditional practice cohort. The higher cost associated with the system-based cohort reflects increased costs for predischarge screening and treatment and increased postdischarge follow-up visits. These costs are partially offset by reduced costs from fewer emergency room visits, hospital readmissions and kernicterus cases. Compared with the traditional approach, the cost to prevent one kernicterus case using the system-based approach was $570,496, the cost per life year gained was $26,279, and the cost per quality-adjusted life year gained was $65,698. The cost to prevent one kernicterus case using the system-based approach is much lower than previously reported in the literature.

  12. Cost-effectiveness analysis of a system-based approach for managing neonatal jaundice and preventing kernicterus in Ontario

    PubMed Central

    Xie, Bin; da Silva, Orlando; Zaric, Greg

    2012-01-01

    OBJECTIVE: To evaluate the incremental cost-effectiveness of a system-based approach for the management of neonatal jaundice and the prevention of kernicterus in term and late-preterm (≥35 weeks) infants, compared with the traditional practice based on visual inspection and selected bilirubin testing. STUDY DESIGN: Two hypothetical cohorts of 150,000 term and late-preterm neonates were used to compare the costs and outcomes associated with the use of a system-based or traditional practice approach. Data for the evaluation were obtained from the case costing centre at a large teaching hospital in Ontario, supplemented by data from the literature. RESULTS: The per child cost for the system-based approach cohort was $176, compared with $173 in the traditional practice cohort. The higher cost associated with the system-based cohort reflects increased costs for predischarge screening and treatment and increased postdischarge follow-up visits. These costs are partially offset by reduced costs from fewer emergency room visits, hospital readmissions and kernicterus cases. Compared with the traditional approach, the cost to prevent one kernicterus case using the system-based approach was $570,496, the cost per life year gained was $26,279, and the cost per quality-adjusted life year gained was $65,698. CONCLUSION: The cost to prevent one kernicterus case using the system-based approach is much lower than previously reported in the literature. PMID:23277747

  13. Comparative Analysis of Sustainable Approaches and Systems for Scientific Data Stewardship

    NASA Astrophysics Data System (ADS)

    Downs, R. R.; Chen, R. S.

    2012-12-01

    Sustainable data systems are critical components of the cyberinfrastructure needed to provide long-term stewardship of scientific data, including Earth science data, throughout their entire life cycle. A variety of approaches may help ensure the sustainability of such systems, but these approaches must be able to survive the demands of competing priorities and decreasing budgets. Analyzing and comparing alternative approaches can identify viable aspects of each approach and inform decisions for developing, managing, and supporting the cyberinfrastructure needed to facilitate discovery, access, and analysis of data by future communities of users. A typology of sustainability approaches is proposed, and example use cases are offered for comparing the approaches over time. These examples demonstrate the potential strengths and weaknesses of each approach under various conditions and with regard to different objectives, e.g., open vs. limited access. By applying the results of these analyses to their particular circumstances, systems stakeholders can assess their options for a sustainable systems approach along with other metrics and identify alternative strategies to ensure the sustainability of the scientific data and information for which they are responsible. In addition, comparing sustainability approaches should inform the design of new systems and the improvement of existing systems to meet the needs for long-term stewardship of scientific data, and support education and workforce development efforts needed to ensure that the appropriate scientific and technical skills are available to operate and further develop sustainable cyberinfrastructure.

  14. Evaluating Recommendation Systems

    NASA Astrophysics Data System (ADS)

    Shani, Guy; Gunawardana, Asela

    Recommender systems are now popular both commercially and in the research community, where many approaches have been suggested for providing recommendations. In many cases a system designer that wishes to employ a recommendation system must choose between a set of candidate approaches. A first step towards selecting an appropriate algorithm is to decide which properties of the application to focus upon when making this choice. Indeed, recommendation systems have a variety of properties that may affect user experience, such as accuracy, robustness, scalability, and so forth. In this paper we discuss how to compare recommenders based on a set of properties that are relevant for the application. We focus on comparative studies, where a few algorithms are compared using some evaluation metric, rather than absolute benchmarking of algorithms. We describe experimental settings appropriate for making choices between algorithms. We review three types of experiments, starting with an offline setting, where recommendation approaches are compared without user interaction, then reviewing user studies, where a small group of subjects experiment with the system and report on the experience, and finally describe large scale online experiments, where real user populations interact with the system. In each of these cases we describe types of questions that can be answered, and suggest protocols for experimentation. We also discuss how to draw trustworthy conclusions from the conducted experiments. We then review a large set of properties, and explain how to evaluate systems given relevant properties. We also survey a large set of evaluation metrics in the context of the properties that they evaluate.

  15. Economic aspects of interlocking hollow brick system designed for industrialized building system

    NASA Astrophysics Data System (ADS)

    Tahir, Mahmood Md.; Saggaff, Anis; Ngian, Shek Poi; Sulaiman, Arizu

    2017-11-01

    Construction industry has moved forward into a technology driven where a transition is in progress from conventional method to a more advanced and mechanised system known as the Industrialised Building System (IBS). However, the need to implement the IBS should be well understood by all construction players such as designer, architect, contraction, erectors and construction workers. Therefore, there is a need to educate all these construction players which should be spearheaded by authorities such as Construction Industrial Development Board where enforcement trough building by laws as well as initiative to those that adopt the IBS in their construction. This paper reports on economic aspects of using interlocking hollow brick system in construction as an alternative method offered for Industrialized Building System. The main objective is to address the economic aspects of using interlocking block system in terms of time, costs, and utilization of manpower and to present some of the experimental tests results related to Interlocking Hollow Brick System (IHBS). Example of savings from the use of IHBS is presented in this paper by comparing the construction of two storey terrace house with build-up area of about 200 square meter with conventional construction method of typical reinforced concrete construction (RCC) compared to IHBS. The comparison shows that the implementation of IHBS can reduce construction time, cost, and utilization of man power up to 26.6% compared to the conventional method. Moreover, the construction time using IHBS can also be reduced by up to 50% as compared to the conventional construction.

  16. The environmental impact of beef production in the United States: 1977 compared with 2007.

    PubMed

    Capper, J L

    2011-12-01

    Consumers often perceive that the modern beef production system has an environmental impact far greater than that of historical systems, with improved efficiency being achieved at the expense of greenhouse gas emissions. The objective of this study was to compare the environmental impact of modern (2007) US beef production with production practices characteristic of the US beef system in 1977. A deterministic model based on the metabolism and nutrient requirements of the beef population was used to quantify resource inputs and waste outputs per billion kilograms of beef. Both the modern and historical production systems were modeled using characteristic management practices, population dynamics, and production data from US beef systems. Modern beef production requires considerably fewer resources than the equivalent system in 1977, with 69.9% of animals, 81.4% of feedstuffs, 87.9% of the water, and only 67.0% of the land required to produce 1 billion kg of beef. Waste outputs were similarly reduced, with modern beef systems producing 81.9% of the manure, 82.3% CH(4), and 88.0% N(2)O per billion kilograms of beef compared with production systems in 1977. The C footprint per billion kilograms of beef produced in 2007 was reduced by 16.3% compared with equivalent beef production in 1977. As the US population increases, it is crucial to continue the improvements in efficiency demonstrated over the past 30 yr to supply the market demand for safe, affordable beef while reducing resource use and mitigating environmental impact.

  17. 76 FR 72931 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-28

    ... Systems (CAHPS) Clinician and Group Survey Comparative Database.'' In accordance with the Paperwork... Providers and Systems (CAHPS) Clinician and Group Survey Comparative Database The Agency for Healthcare..., and provided critical data illuminating key aspects of survey design and administration. In July 2007...

  18. COMPARATIVE STUDY OF AIR CLASSIFIERS

    EPA Science Inventory

    This report describes the results of field tests of seven different air classifier systems. The systems are compared in regard to (a) their capacity to handle refuse and separate it into a heavy fraction and a light fuel fraction, (b) their ability to concentrate lights in the li...

  19. REMOVAL AND CONTAINMENT OF LEAD-BASED PAINT VIA NEEDLE SCALERS

    EPA Science Inventory

    This report describes a comparative technical and economic evaluation of using a dustless needlegun system versus a conventional abrasive grit blasting system in the removal of lead-based paint from steel structures. The objective of the study was to comparatively analyze the ope...

  20. COMPARATIVE DISINFECTION EFFICIENCY OF PULSED AND CONTINUOUS-WAVE UV IRRADIATION TECHNOLOGIES

    EPA Science Inventory

    Pulsed UV (PUV) is novel UV irradiation system that is a non-mercury lamp based alternative to currently used continuous-wave systems for water disinfection. To compare the polychromatic PUV irradiation disinfection efficiency with that from continuous wave monochromatic low-pre...

  1. Profitability of Cropping Systems Featuring Tillage and Compost

    USDA-ARS?s Scientific Manuscript database

    Productivity rather than profitability is often used to compare agronomic systems. Increasing energy prices will force producers to scrutinize machinery operation and input costs, which will shift emphasis to profitability. The objective of this study was to compare returns to land and management fo...

  2. A Method for Comparing Multivariate Time Series with Different Dimensions

    PubMed Central

    Tapinos, Avraam; Mendes, Pedro

    2013-01-01

    In many situations it is desirable to compare dynamical systems based on their behavior. Similarity of behavior often implies similarity of internal mechanisms or dependency on common extrinsic factors. While there are widely used methods for comparing univariate time series, most dynamical systems are characterized by multivariate time series. Yet, comparison of multivariate time series has been limited to cases where they share a common dimensionality. A semi-metric is a distance function that has the properties of non-negativity, symmetry and reflexivity, but not sub-additivity. Here we develop a semi-metric – SMETS – that can be used for comparing groups of time series that may have different dimensions. To demonstrate its utility, the method is applied to dynamic models of biochemical networks and to portfolios of shares. The former is an example of a case where the dependencies between system variables are known, while in the latter the system is treated (and behaves) as a black box. PMID:23393554

  3. [Mechanical testing of implant properties of thoracoscopic implantation of ventral spinal stabilizing systems. Comparative study with the ISO/DIS 12189-2 corpectomy model and an improved synthetic model].

    PubMed

    Grupp, T M; Beisse, R; Potulski, M; Marnay, T; Beger, J; Blömer, W

    2002-04-01

    A new modular anterior fixation system MACS TL (modular anterior construct system for the thoracic and lumbar spine) has been developed for use in thoracoscopic spondylodesis. This system demonstrates high angular stability and meets the surgical requirements for an endoscopic approach. The objective of the current study was fatigue testing of the MACS TL implant system using a corpectomy model according to ISO/DIS 12189-2 and a synthetic model recently developed by Kotani et al. [6]. The MACS TL system demonstrated good mechanical properties with a high stiffness compared to the published data reviewed. The importance of dynamic testing in a corpectomy model has been demonstrated by comparing the MACS TL plate system with an early prototype, which has not yet been clinically evaluated. The corpectomy model according to Kotani et al. offers an interesting alternative to the ISO/DIS 12189-2 test method for asymmetrically designed and antero-laterally positioned spinal implants due to the unconstrained ball joint.

  4. Feasibility study of a TIMEPIX detector for mammography applications

    NASA Astrophysics Data System (ADS)

    Ávila, Carlos A.; Mendoza, Luis M.; Roque, Gerardo A.; Loaiza, Leonardo; Racedo, Jorge; Rueda, Roberto

    2017-11-01

    We present a comparison study of two X-ray systems for mammography imaging. One is a SELENIA clinical system and the second is a TIMEPIX based system. The aim of the study is to determine the capability of a TIMEPIX detector for mammography applications. We first compare signal to noise ratio (SNR) of X-ray images of Al2O3 spheres with diameters of 0.16mm, 0.24mm and 0.32mm, of a commercial mammography accreditation phantom CIRS015, obtained with each system. Then, we make a similar comparison for a second phantom built with Hydroxyapatite crystals with different morphology and sizes ranging between 0.15mm and 0.83mm, which are embedded within the same block of PMMA of the CIRS015 phantom. Our study allows us to determine the minimum size of Al2O3 spheres on the order of 240μm, with 33% lower SNR for the TIMEPIX system as compared to the SELENIA system. When comparing the images of Hydroxyapatite crystals from both systems, the minimum size observed is about 300μm, with 23% lower SNR for TIMEPIX.

  5. Ground-Based and Space-Based Laser Beam Power Applications

    NASA Technical Reports Server (NTRS)

    Bozek, John M.

    1995-01-01

    A space power system based on laser beam power is sized to reduce mass, increase operational capabilities, and reduce complexity. The advantages of laser systems over solar-based systems are compared as a function of application. Power produced from the conversion of a laser beam that has been generated on the Earth's surface and beamed into cislunar space resulted in decreased round-trip time for Earth satellite electric propulsion tugs and a substantial landed mass savings for a lunar surface mission. The mass of a space-based laser system (generator in space and receiver near user) that beams down to an extraterrestrial airplane, orbiting spacecraft, surface outpost, or rover is calculated and compared to a solar system. In general, the advantage of low mass for these space-based laser systems is limited to high solar eclipse time missions at distances inside Jupiter. The power system mass is less in a continuously moving Mars rover or surface outpost using space-based laser technology than in a comparable solar-based power system, but only during dust storm conditions. Even at large distances for the Sun, the user-site portion of a space-based laser power system (e.g., the laser receiver component) is substantially less massive than a solar-based system with requisite on-board electrochemical energy storage.

  6. Comparative antibacterial efficacies of hydrodynamic and ultrasonic irrigation systems in vitro.

    PubMed

    Cachovan, Georg; Schiffner, Ulrich; Altenhof, Saskia; Guentsch, Arndt; Pfister, Wolfgang; Eick, Sigrun

    2013-09-01

    To ensure root canal treatment success, endodontic microbiota should be efficiently reduced. The in vitro bactericidal effects of a hydrodynamic system and a passive ultrasonic irrigation system were compared. Single-rooted extracted teeth (n = 250) were contaminated with suspensions of Enterococcus faecalis ATCC 29212, mixed aerobic cultures, or mixed anaerobic cultures. First, the antibacterial effects of the hydrodynamic system (RinsEndo), a passive ultrasonic irrigation system (Piezo smart), and manual rinsing with 0.9% NaCl (the control) were compared. Colony-forming units were counted. Second, the 2 systems were used with 1.5% sodium hypochlorite (NaOCl) alone or NaOCl + 0.2% chlorhexidine (CHX). The colony-forming units in the treated and untreated roots were determined during a period of 5 days. Both irrigation systems reduced bacterial numbers more effectively than manual rinsing (P < .001). With NaCl, ultrasonic activated irrigation reduced bacterial counts significantly better than hydrodynamic irrigation (P = .042). The NaOCl + CHX combination was more effective than NaOCl alone for both systems (P < .001), but hydrodynamic irrigation was more effective with NaOCl + CHX than the passive ultrasonic irrigation system. Both irrigation systems, when combined with NaOCl + CHX, removed bacteria from root canals. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Evaluation of a digital drainage system (Thopaz) in over 250 cases at a single site: A retrospective case-control study.

    PubMed

    Arai, Hiromasa; Tajiri, Michihiko; Kameda, Yohei; Shiino, Kimihisa; Ando, Kohei; Okudela, Koji; Masuda, Munetaka

    2018-04-01

    The aim of this study was to evaluate the efficacy of the Thopaz system, a new drainage system in management of general thoracic surgery, based on a review of our clinical practice and a comparison of the utility of the Thopaz device compared with a standard drainage system. A review of 540 thoracic surgeries at our hospital was performed. These cases were divided into 275 treated with the Thopaz system from April 2014 to March 2015 and 265 treated with a standard system from April 2013 to March 2014. The characteristics of patients and outcomes after surgery were compared in these 2 groups. The characteristics of the patients were similar in the 2 groups. Outcomes after surgery, including types of operation, period of chest tube placement, chest tube reinsertion rate and clamping test rate also did not differ significantly between the groups. The non-inferiority of the Thopaz system compared to a standard system was verified statistically. With advantages of providing objective data as a small portable system, in addition to the quietness of the unit and the ease of setup and operation, Thopaz system is likely to become mainstream in postoperative management in general thoracic surgery. © 2017 John Wiley & Sons Ltd.

  8. Improvements to the Hunter Dose tracking system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiteside, T. S.; Aucott, T. J.; Brand, A. D.

    Since 1965, the Savannah River Site (SRS) has conducted deer hunts which are open to the general public. SRS performs field monitoring for cesium-137 (Cs-137) of each harvested animal to determine whether the animal may be released to the hunter. A new field system for measuring Cs-137 in the harvested animals has been developed. The system incorporates numerous enhancements compared to the original system. The original system was composed of two Ludlum Measurements scalar-driven 2 inch x 2 inch sodium iodide counters, while the new system is based on a single Ametek Ortec Digibase-driven 2 inch x 4 inch xmore » 16 inch sodium iodide gamma spectrometer. The new system includes a series of easy-to-assemble stainless steel encapsulated lead shields. The combination of the larger detector size and lead shielding improved the detection limit of the new system by a factor of approximately three compared to the original system. This lower detection limit allows for a larger number of measurements to be directly compared to the laboratory results, in cases where animal portions have been sampled. The results from developing and using this system are presented as well as recommendations on improvements to the overall field monitoring of the SRS hunts.« less

  9. Diagnostic quality of 50 and 100 µm computed radiography compared with screen–film mammography in operative breast specimens

    PubMed Central

    Pagliari, C M; Hoang, T; Reddy, M; Wilkinson, L S; Poloniecki, J D; Given-Wilson, R M

    2012-01-01

    Objective To compare reader ratings of the clinical diagnostic quality of 50 and 100 μm computed radiography (CR) systems with screen–film mammography (SFM) in operative specimens. Methods Mammograms of 57 fresh operative breast specimens were analysed by 10 readers. Exposures were made with identical position and compression with three mammographic systems (Fuji 100CR, 50CR and SFM). Images were anonymised and readers blinded to the CR system used. A five-point comparative scoring system (−2 to +2) was used to assess seven quality criteria and overall diagnostic value. Statistical analysis was subsequently performed of reader ratings (n=16 925). Results For most quality criteria, both CR systems were rated as equivalent to or better than SFM. The CR systems were significantly better at demonstrating skin edge and background tissue (p<1×10−5). Microcalcification was best demonstrated on the CR50 system (p<1×10−5). The overall diagnostic value of both CR systems was rated as being as good as or better than SFM (p<1×10−5). Conclusion In this clinical setting, the overall diagnostic performance of both CR systems was as good as or better than SFM, with the CR50 system performing better than the CR100. PMID:22096218

  10. Quantitative evaluation of apically extruded debris with different single-file systems: Reciproc, F360 and OneShape versus Mtwo.

    PubMed

    Bürklein, S; Benten, S; Schäfer, E

    2014-05-01

    To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system. Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05). Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. Partial liquid ventilation: effects of closed breathing systems, heat-and-moisture-exchangers and sodalime absorbers on perfluorocarbon evaporation.

    PubMed

    Wilms, C T; Schober, P; Kalb, R; Loer, S A

    2006-01-01

    During partial liquid ventilation perfluorocarbons are instilled into the airways from where they subsequently evaporate via the bronchial system. This process is influenced by multiple factors, such as the vapour pressure of the perfluorocarbons, the instilled volume, intrapulmonary perfluorocarbon distribution, postural positioning and ventilatory settings. In our study we compared the effects of open and closed breathing systems, a heat-and-moisture-exchanger and a sodalime absorber on perfluorocarbon evaporation during partial liquid ventilation. Isolated rat lungs were suspended from a force transducer. After intratracheal perfluorocarbon instillation (10 mL kg(-1)) the lungs were either ventilated with an open breathing system (n = 6), a closed breathing system (n = 6), an open breathing system with an integrated heat-and-moisture-exchanger (n = 6), an open breathing system with an integrated sodalime absorber (n = 6), or a closed breathing system with an integrated heat-and-moisture-exchanger and a sodalime absorber (n = 6). Evaporative perfluorocarbon elimination was determined gravimetrically. When compared to the elimination half-life in an open breathing system (1.2 +/- 0.07 h), elimination half-life was longer with a closed system (6.4 +/- 0.9 h, P 0.05) when compared to a closed system. Evaporative perfluorocarbon loss can be reduced effectively with closed breathing systems, followed by the use of sodalime absorbers and heat-and-moisture-exchangers.

  12. A dual cone-beam CT system for image guided radiotherapy: initial performance characterization.

    PubMed

    Li, Hao; Giles, William; Bowsher, James; Yin, Fang-Fang

    2013-02-01

    The purpose of this study is to evaluate the performance of a recently developed benchtop dual cone-beam computed tomography (CBCT) system with two orthogonally placed tube∕detector sets. The benchtop dual CBCT system consists of two orthogonally placed 40 × 30 cm flat-panel detectors and two conventional x-ray tubes with two individual high-voltage generators sharing the same rotational axis. The x-ray source to detector distance is 150 cm and x-ray source to rotational axis distance is 100 cm for both subsystems. The objects are scanned through 200° of rotation. The dual CBCT system utilized 110° of projection data from one detector and 90° from the other while the two individual single CBCTs utilized 200° data from each detector. The system performance was characterized in terms of uniformity, contrast, spatial resolution, noise power spectrum, and CT number linearity. The uniformities, within the axial slice and along the longitudinal direction, and noise power spectrum were assessed by scanning a water bucket; the contrast and CT number linearity were measured using the Catphan phantom; and the spatial resolution was evaluated using a tungsten wire phantom. A skull phantom and a ham were also scanned to provide qualitative evaluation of high- and low-contrast resolution. Each measurement was compared between dual and single CBCT systems. Compared to single CBCT, the dual CBCT presented: (1) a decrease in uniformity by 1.9% in axial view and 1.1% in the longitudinal view, as averaged for four energies (80, 100, 125, and 150 kVp); (2) comparable or slightly better contrast (0∼25 HU) for low-contrast objects and comparable contrast for high-contrast objects; (3) comparable spatial resolution; (4) comparable CT number linearity with R(2) ≥ 0.99 for all four tested energies; (5) lower noise power spectrum in magnitude. Dual CBCT images of the skull phantom and the ham demonstrated both high-contrast resolution and good soft-tissue contrast. The performance of a benchtop dual CBCT imaging system has been characterized and is comparable to that of a single CBCT.

  13. Role of Hot Water System Design on Factors Influential to Pathogen Regrowth: Temperature, Chlorine Residual, Hydrogen Evolution, and Sediment

    PubMed Central

    Brazeau, Randi H.; Edwards, Marc A.

    2013-01-01

    Abstract Residential water heating is linked to growth of pathogens in premise plumbing, which is the primary source of waterborne disease in the United States. Temperature and disinfectant residual are critical factors controlling increased concentration of pathogens, but understanding of how each factor varies in different water heater configurations is lacking. A direct comparative study of electric water heater systems was conducted to evaluate temporal variations in temperature and water quality parameters including dissolved oxygen levels, hydrogen evolution, total and soluble metal concentrations, and disinfectant decay. Recirculation tanks had much greater volumes of water at temperature ranges with potential for increased pathogen growth when set at 49°C compared with standard tank systems without recirculation. In contrast, when set at the higher end of acceptable ranges (i.e., 60°C), this relationship was reversed and recirculation systems had less volume of water at risk for pathogen growth compared with conventional systems. Recirculation tanks also tended to have much lower levels of disinfectant residual (standard systems had 40–600% higher residual), 4–6 times as much hydrogen, and 3–20 times more sediment compared with standard tanks without recirculation. On demand tankless systems had very small volumes of water at risk and relatively high levels of disinfectant residual. Recirculation systems may have distinct advantages in controlling pathogens via thermal disinfection if set at 60°C, but these systems have lower levels of disinfectant residual and greater volumes at risk if set at lower temperatures. PMID:24170969

  14. Success Factors of European Syndromic Surveillance Systems: A Worked Example of Applying Qualitative Comparative Analysis

    PubMed Central

    Ziemann, Alexandra; Fouillet, Anne; Brand, Helmut; Krafft, Thomas

    2016-01-01

    Introduction Syndromic surveillance aims at augmenting traditional public health surveillance with timely information. To gain a head start, it mainly analyses existing data such as from web searches or patient records. Despite the setup of many syndromic surveillance systems, there is still much doubt about the benefit of the approach. There are diverse interactions between performance indicators such as timeliness and various system characteristics. This makes the performance assessment of syndromic surveillance systems a complex endeavour. We assessed if the comparison of several syndromic surveillance systems through Qualitative Comparative Analysis helps to evaluate performance and identify key success factors. Materials and Methods We compiled case-based, mixed data on performance and characteristics of 19 syndromic surveillance systems in Europe from scientific and grey literature and from site visits. We identified success factors by applying crisp-set Qualitative Comparative Analysis. We focused on two main areas of syndromic surveillance application: seasonal influenza surveillance and situational awareness during different types of potentially health threatening events. Results We found that syndromic surveillance systems might detect the onset or peak of seasonal influenza earlier if they analyse non-clinical data sources. Timely situational awareness during different types of events is supported by an automated syndromic surveillance system capable of analysing multiple syndromes. To our surprise, the analysis of multiple data sources was no key success factor for situational awareness. Conclusions We suggest to consider these key success factors when designing or further developing syndromic surveillance systems. Qualitative Comparative Analysis helped interpreting complex, mixed data on small-N cases and resulted in concrete and practically relevant findings. PMID:27182731

  15. Success Factors of European Syndromic Surveillance Systems: A Worked Example of Applying Qualitative Comparative Analysis.

    PubMed

    Ziemann, Alexandra; Fouillet, Anne; Brand, Helmut; Krafft, Thomas

    2016-01-01

    Syndromic surveillance aims at augmenting traditional public health surveillance with timely information. To gain a head start, it mainly analyses existing data such as from web searches or patient records. Despite the setup of many syndromic surveillance systems, there is still much doubt about the benefit of the approach. There are diverse interactions between performance indicators such as timeliness and various system characteristics. This makes the performance assessment of syndromic surveillance systems a complex endeavour. We assessed if the comparison of several syndromic surveillance systems through Qualitative Comparative Analysis helps to evaluate performance and identify key success factors. We compiled case-based, mixed data on performance and characteristics of 19 syndromic surveillance systems in Europe from scientific and grey literature and from site visits. We identified success factors by applying crisp-set Qualitative Comparative Analysis. We focused on two main areas of syndromic surveillance application: seasonal influenza surveillance and situational awareness during different types of potentially health threatening events. We found that syndromic surveillance systems might detect the onset or peak of seasonal influenza earlier if they analyse non-clinical data sources. Timely situational awareness during different types of events is supported by an automated syndromic surveillance system capable of analysing multiple syndromes. To our surprise, the analysis of multiple data sources was no key success factor for situational awareness. We suggest to consider these key success factors when designing or further developing syndromic surveillance systems. Qualitative Comparative Analysis helped interpreting complex, mixed data on small-N cases and resulted in concrete and practically relevant findings.

  16. The Effects of Post-Compulsory Education and Training Systems on Literacy and Numeracy Skills: A Comparative Analysis Using PISA 2000 and the 2011 Survey of Adult Skills

    ERIC Educational Resources Information Center

    Pensiero, Nicola; Green, Andy

    2018-01-01

    This article analyses the contribution of post-compulsory education and training systems to the development of literacy and numeracy skills across OECD countries. While there is extensive cross-country comparative research on the effects of primary and lower secondary education systems on aggregate skills levels, there has been little comparative…

  17. The Influence of Educational Systems on the Academic Performance of JSCE Students in Rivers State

    ERIC Educational Resources Information Center

    Orluwene, Goodness W.; Igwe, Benjamin N.

    2015-01-01

    This work is a comparative study of JSCE results between the 6-3-3-4 system (2006 & 2008) and the 9-3-4 (UBE) system (2009 & 2011) in Port Harcourt using a comparative/evaluative survey design. A cluster sampling technique was used to compose a sample of 2,487 drawn from the population of 17,139 candidates in 2006, 2008, 2009 and 2011 in…

  18. Filter performance parameters for vectorial high-aperture wave fields.

    PubMed

    Sheppard, Colin J R; Martinez-Corral, M

    2008-03-01

    Performance parameters have been presented that can be used to compare the focusing performance of different optical systems, including the effect of pupil filters. These were originally given for the paraxial case and recently extended to the high-aperture scalar regime. We generalize these parameters to the full vectorial case for an aplanatic optical system illuminated by a plane-polarized wave. The behavior of different optical systems is compared.

  19. An Inquiry into Testing of Information Retrieval Systems. Comparative Systems Laboratory Final Technical Report, Part III: CSL Related Studies.

    ERIC Educational Resources Information Center

    Zull, Carolyn Gifford, Ed.; And Others

    This third volume of the Comparative Systems Laboratory (CSL) Final Technical Report is a collection of relatively independent studies performed on CSL materials. Covered in this document are studies on: (1) properties of files, including a study of the growth rate of a dictionary of index terms as influenced by number of documents in the file and…

  20. A comparison of the Health Star Rating system when used for restaurant fast foods and packaged foods.

    PubMed

    Dunford, Elizabeth K; Wu, Jason H Y; Wellard-Cole, Lyndal; Watson, Wendy; Crino, Michelle; Petersen, Kristina; Neal, Bruce

    2017-10-01

    In June 2014, the Australian government agreed to the voluntary implementation of an interpretive 'Health Star Rating' (HSR) front-of-pack labelling system for packaged foods. The aim of the system is to make it easier for consumers to compare the healthiness of products based on number of stars. With many Australians consuming fast food there is a strong rationale for extending the HSR system to include fast food items. To examine the performance of the HSR system when applied to fast foods. Nutrient content data for fast food menu items were collected from the websites of 13 large Australian fast-food chains. The HSR was calculated for each menu item. Statistics describing HSR values for fast foods were calculated and compared to results for comparable packaged foods. Data for 1529 fast food products were compared to data for 3810 packaged food products across 16 of 17 fast food product categories. The mean HSR for the fast foods was 2.5 and ranged from 0.5 to 5.0 and corresponding values for the comparator packaged foods were 2.6 and 0.5 to 5.0. Visual inspection of the data showed broadly comparable distributions of HSR values across the fast food and the packaged food categories, although statistically significant differences were apparent for seven categories (all p < 0.04). In some cases these differences reflected the large sample size and the power to detect small variations across fast foods and packaged food, and in others it appeared to reflect primarily differences in the mix of product types within a category. These data support the idea that the HSR system could be extended to Australian fast foods. There are likely to be significant benefits to the community from the use of a single standardised signposting system for healthiness across all fresh, packaged and restaurant foods. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Randomised trial comparing the recording ability of a novel, electronic emergency documentation system with the AHA paper cardiac arrest record.

    PubMed

    Grigg, Eliot; Palmer, Andrew; Grigg, Jeffrey; Oppenheimer, Peter; Wu, Tim; Roesler, Axel; Nair, Bala; Ross, Brian

    2014-10-01

    To evaluate the ability of an electronic system created at the University of Washington to accurately document prerecorded VF and pulseless electrical activity (PEA) cardiac arrest scenarios compared with the American Heart Association paper cardiac arrest record. 16 anaesthesiology residents were randomly assigned to view one of two prerecorded, simulated VF and PEA scenarios and asked to document the event with either the paper or electronic system. Each subject then repeated the process with the other video and documentation method. Five types of documentation errors were defined: (1) omission, (2) specification, (3) timing, (4) commission and (5) noise. The mean difference in errors between the paper and electronic methods was analysed using a single factor repeated measures ANOVA model. Compared with paper records, the electronic system omitted 6.3 fewer events (95% CI -10.1 to -2.5, p=0.003), which represents a 28% reduction in omission errors. Users recorded 2.9 fewer noise items (95% CI -5.3 to -0.6, p=0.003) when compared with paper, representing a 36% decrease in redundant or irrelevant information. The rate of timing (Δ=-3.2, 95% CI -9.3 to 3.0, p=0.286) and commission (Δ=-4.4, 95% CI -9.4 to 0.5, p=0.075) errors were similar between the electronic system and paper, while the rate of specification errors were about a third lower for the electronic system when compared with the paper record (Δ=-3.2, 95% CI -6.3 to -0.2, p=0.037). Compared with paper documentation, documentation with the electronic system captured 24% more critical information during a simulated medical emergency without loss in data quality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. The risk of upcoding in casemix systems: a comparative study.

    PubMed

    Steinbusch, Paul J M; Oostenbrink, Jan B; Zuurbier, Joost J; Schaepkens, Frans J M

    2007-05-01

    With the introduction of a diagnosis related group (DRG) classification system in the Netherlands in 2005 it has become relevant to investigate the risk of upcoding. The problem of upcoding in the US casemix system is substantial. In 2004, the US Centres for Medicare and Medicaid estimated that the total number of improper Medicare payments for the Prospective Payment system for acute inpatient care (both short term and long term) amounted to US$ 4.8 billion (5.2%). By comparing the casemix systems in the US, Australian and Dutch healthcare systems, this article illustrates why certain casemix systems are more open to the risk of upcoding than other systems. This study identifies various market, control and casemix characteristics determining the weaknesses of a casemix reimbursement system to upcoding. It can be concluded that fewer opportunities for upcoding occur in casemix systems that do not allow for-profit ownership and in which the coder's salary does not depend on the outcome of the classification process. In addition, casemix systems in which the first point in time of registration is at the beginning of the care process and in which there are a limited number of occasions to alter the registration are less vulnerable to the risk of upcoding. Finally, the risk of upcoding is smaller in casemix systems that use classification criteria that are medically meaningful and aligned with clinical practice. Comparing the US, Australian and Dutch systems the following conclusions can be drawn. Given the combined occurrences of for-profit hospitals and the use of the secondary diagnosis criterion to classify DRGs, the US casemix system tends to be more open to upcoding than the Australian system. The strength of the Dutch system is related to the detailed classification scheme, using medically meaningful classification criteria. Nevertheless, the detailed classification scheme also causes a weakness, because of its increased complexity compared with the US and Australian system. It is recommended that researchers and policy makers carefully consider all relevant market, control and casemix characteristics when developing and restructuring casemix reimbursement systems.

  3. Advanced Active Thermal Control Systems Architecture Study

    NASA Technical Reports Server (NTRS)

    Hanford, Anthony J.; Ewert, Michael K.

    1996-01-01

    The Johnson Space Center (JSC) initiated a dynamic study to determine possible improvements available through advanced technologies (not used on previous or current human vehicles), identify promising development initiatives for advanced active thermal control systems (ATCS's), and help prioritize funding and personnel distribution among many research projects by providing a common basis to compare several diverse technologies. Some technologies included were two-phase thermal control systems, light-weight radiators, phase-change thermal storage, rotary fluid coupler, and heat pumps. JSC designed the study to estimate potential benefits from these various proposed and under-development thermal control technologies for five possible human missions early in the next century. The study compared all the technologies to a baseline mission using mass as a basis. Each baseline mission assumed an internal thermal control system; an external thermal control system; and aluminum, flow-through radiators. Solar vapor compression heat pumps and light-weight radiators showed the greatest promise as general advanced thermal technologies which can be applied across a range of missions. This initial study identified several other promising ATCS technologies which offer mass savings and other savings compared to traditional thermal control systems. Because the study format compares various architectures with a commonly defined baseline, it is versatile and expandable, and is expected to be updated as needed.

  4. Fractionation of Cl/Br during fluid phase separation in magmatic-hydrothermal fluids

    NASA Astrophysics Data System (ADS)

    Seo, Jung Hun; Zajacz, Zoltán

    2016-06-01

    Brine and vapor inclusions were synthesized to study Cl/Br fractionation during magmatic-hydrothermal fluid phase separation at 900 °C and pressures of 90, 120, and 150 MPa in Li/Na/K halide salt-H2O systems. Laser ablation ICP-MS microanalysis of high-density brine inclusions show an elevated Cl/Br ratio compared to the coexisting low-density vapor inclusions. The degree of Cl/Br fractionation between vapor and brine is significantly dependent on the identity of the alkali metal in the system: stronger vapor partitioning of Br occurs in the Li halide-H2O system compared to the systems of K and Na halide-H2O. The effect of the identity of alkali-metals in the system is stronger compared to the effect of vapor-brine density contrast. We infer that competition between alkali-halide and alkali-OH complexes in high-temperature fluids might cause the Cl/Br fractionation, consistent with the observed molar imbalances of alkali metals compared to halides in the analyzed brine inclusions. Our experiments show that the identity of alkali metals controls the degrees of Cl/Br fractionation between the separating aqueous fluid phases at 900 °C, and suggest that a significant variability in the Cl/Br ratios of magmatic fluids can arise in Li-rich systems.

  5. Air Pressure Controlled Mass Measurement System

    NASA Astrophysics Data System (ADS)

    Zhong, Ruilin; Wang, Jian; Cai, Changqing; Yao, Hong; Ding, Jin'an; Zhang, Yue; Wang, Xiaolei

    Mass measurement is influenced by air pressure, temperature, humidity and other facts. In order to reduce the influence, mass laboratory of National Institute of Metrology, China has developed an air pressure controlled mass measurement system. In this system, an automatic mass comparator is installed in an airtight chamber. The Chamber is equipped with a pressure controller and associate valves, thus the air pressure can be changed and stabilized to the pre-set value, the preferred pressure range is from 200 hPa to 1100 hPa. In order to keep the environment inside the chamber stable, the display and control part of the mass comparator are moved outside the chamber, and connected to the mass comparator by feed-throughs. Also a lifting device is designed for this system which can easily lift up the upper part of the chamber, thus weights can be easily put inside the mass comparator. The whole system is put on a marble platform, and the temperature and humidity of the laboratory is very stable. The temperature, humidity, and carbon dioxide content inside the chamber are measured in real time and can be used to get air density. Mass measurement cycle from 1100 hPa to 200 hPa and back to 1100 hPa shows the effective of the system.

  6. SIMS(DAIRY): a modelling framework to identify sustainable dairy farms in the UK. Framework description and test for organic systems and N fertiliser optimisation.

    PubMed

    Del Prado, A; Misselbrook, T; Chadwick, D; Hopkins, A; Dewhurst, R J; Davison, P; Butler, A; Schröder, J; Scholefield, D

    2011-09-01

    Multiple demands are placed on farming systems today. Society, national legislation and market forces seek what could be seen as conflicting outcomes from our agricultural systems, e.g. food quality, affordable prices, a healthy environmental, consideration of animal welfare, biodiversity etc., Many of these demands, or desirable outcomes, are interrelated, so reaching one goal may often compromise another and, importantly, pose a risk to the economic viability of the farm. SIMS(DAIRY), a farm-scale model, was used to explore this complexity for dairy farm systems. SIMS(DAIRY) integrates existing approaches to simulate the effect of interactions between farm management, climate and soil characteristics on losses of nitrogen, phosphorus and carbon. The effects on farm profitability and attributes of biodiversity, milk quality, soil quality and animal welfare are also included. SIMS(DAIRY) can also be used to optimise fertiliser N. In this paper we discuss some limitations and strengths of using SIMS(DAIRY) compared to other modelling approaches and propose some potential improvements. Using the model we evaluated the sustainability of organic dairy systems compared with conventional dairy farms under non-optimised and optimised fertiliser N use. Model outputs showed for example, that organic dairy systems based on grass-clover swards and maize silage resulted in much smaller total GHG emissions per l of milk and slightly smaller losses of NO(3) leaching and NO(x) emissions per l of milk compared with the grassland/maize-based conventional systems. These differences were essentially because the conventional systems rely on indirect energy use for 'fixing' N compared with biological N fixation for the organic systems. SIMS(DAIRY) runs also showed some other potential benefits from the organic systems compared with conventional systems in terms of financial performance and soil quality and biodiversity scores. Optimisation of fertiliser N timings and rates showed a considerable scope to reduce the (GHG emissions per l milk too). Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Interruption as a test of the user-computer interface

    NASA Technical Reports Server (NTRS)

    Kreifeldt, J. G.; Mccarthy, M. E.

    1981-01-01

    In order to study the effects different logic systems might have on interrupted operation, an algebraic calculator and a reverse polish notation calculator were compared when trained users were interrupted during problem entry. The RPN calculator showed markedly superior resistance to interruption effects compared to the AN calculator although no significant differences were found when the users were not interrupted. Causes and possible remedies for interruption effects are speculated. It is proposed that because interruption is such a common occurrence, it be incorporated into comparative evaluation tests of different logic system and control/display system and that interruption resistance be adopted as a specific design criteria for such design.

  8. A novel system for automated propofol sedation: hybrid sedation system (HSS).

    PubMed

    Zaouter, Cedrick; Taddei, Riccardo; Wehbe, Mohamad; Arbeid, Erik; Cyr, Shantale; Giunta, Francesco; Hemmerling, Thomas M

    2017-04-01

    Closed-loop systems for propofol have been demonstrated to be safe and reliable for general anesthesia. However, no study has been conducted using a closed-loop system specifically designed for sedation in patients under spinal anesthesia. We developed an automatic anesthesia sedation system that allows for closed-loop delivery of propofol for sedation integrating a decision support system, called the hybrid sedation system (HSS). The objective of this study is to compare this system with standard practice. One hundred fifty patients were enrolled and randomly assigned to two groups: HSS-Group (N = 75), in which propofol was administered using a closed-loop system; Control Group (N = 75), in which propofol was delivered manually. The clinical performance of the propofol sedation control is defined as efficacy to maintain bispectral index (BIS) near 65. The clinical control was called 'Excellent', 'Good', 'Poor' and 'Inadequate' with BIS values within 10 %, from 11 to 20 %, 21 to 30 %, or greater than 30 % of the BIS target of 65, respectively. The controller performance was evaluated using Varvel's parameters. Data are presented as mean ± standard deviation, groups were compared using t test or Chi square test, P < 0.05. Clinical performance of sedation showed 'Excellent' control in the HSS-group for a significantly longer period of time (49 vs. 26 % in the control group, P < 0.0001). 'Poor' and 'Inadequate' sedation was significantly shorter in the HSS Group compared to the Control Group (11 and 10 % vs. 20 and 18 %, respectively, P < 0.0001). The novel, closed-loop system for propofol sedation showed better maintenance of the target BIS value compared to manual administration.

  9. Effects of housing system on the costs of commercial egg production1

    PubMed Central

    Matthews, W. A.; Sumner, D. A.

    2014-01-01

    This article reports the first publicly available egg production costs compared across 3 hen-housing systems. We collected detailed data from 2 flock cycles from a commercial egg farm operating a conventional barn, an aviary, and an enriched colony system at the same location. The farm employed the same operational and accounting procedures for each housing system. Results provide clear evidence that egg production costs are much higher for the aviary system than the other 2 housing systems. Feed costs per dozen eggs are somewhat higher for the aviary and lower for the enriched house compared with the conventional house. Labor costs are much lower for the conventional house than the other 2, and pullet costs are much higher for the aviary. Energy and miscellaneous costs are a minimal part of total operating costs and do not differ by housing system. Total capital investments per hen-capacity are much higher for the aviary and the enriched house. Capital costs per dozen eggs depend on assumptions about appropriate interest and depreciation rates. Using the same 10% rate for each housing system shows capital costs per dozen for the aviary and the enriched housing system are much higher than capital costs per dozen for the conventional house. The aviary has average operating costs (feed, labor, pullet, energy, and miscellaneous costs that recur for each flock and vary with egg production) about 23% higher and average total costs about 36% higher compared with the conventional house. The enriched housing system has average operating costs only about 4% higher compared with the conventional house, but average total costs are 13% higher than for the conventional house. PMID:25480736

  10. Effects of housing system on the costs of commercial egg production.

    PubMed

    Matthews, W A; Sumner, D A

    2015-03-01

    This article reports the first publicly available egg production costs compared across 3 hen-housing systems. We collected detailed data from 2 flock cycles from a commercial egg farm operating a conventional barn, an aviary, and an enriched colony system at the same location. The farm employed the same operational and accounting procedures for each housing system. Results provide clear evidence that egg production costs are much higher for the aviary system than the other 2 housing systems. Feed costs per dozen eggs are somewhat higher for the aviary and lower for the enriched house compared with the conventional house. Labor costs are much lower for the conventional house than the other 2, and pullet costs are much higher for the aviary. Energy and miscellaneous costs are a minimal part of total operating costs and do not differ by housing system. Total capital investments per hen-capacity are much higher for the aviary and the enriched house. Capital costs per dozen eggs depend on assumptions about appropriate interest and depreciation rates. Using the same 10% rate for each housing system shows capital costs per dozen for the aviary and the enriched housing system are much higher than capital costs per dozen for the conventional house. The aviary has average operating costs (feed, labor, pullet, energy, and miscellaneous costs that recur for each flock and vary with egg production) about 23% higher and average total costs about 36% higher compared with the conventional house. The enriched housing system has average operating costs only about 4% higher compared with the conventional house, but average total costs are 13% higher than for the conventional house. © The Author 2015. Published by Oxford University Press on behalf of Poultry Science Association.

  11. Mapping healthcare systems: a policy relevant analytic tool

    PubMed Central

    Sekhri Feachem, Neelam; Afshar, Ariana; Pruett, Cristina; Avanceña, Anton L.V.

    2017-01-01

    Abstract Background In the past decade, an international consensus on the value of well-functioning systems has driven considerable health systems research. This research falls into two broad categories. The first provides conceptual frameworks that take complex healthcare systems and create simplified constructs of interactions and functions. The second focuses on granular inputs and outputs. This paper presents a novel translational mapping tool – the University of California, San Francisco mapping tool (the Tool) - which bridges the gap between these two areas of research, creating a platform for multi-country comparative analysis. Methods Using the Murray-Frenk framework, we create a macro-level representation of a country's structure, focusing on how it finances and delivers healthcare. The map visually depicts the fundamental policy questions in healthcare system design: funding sources and amount spent through each source, purchasers, populations covered, provider categories; and the relationship between these entities. Results We use the Tool to provide a macro-level comparative analysis of the structure of India's and Thailand's healthcare systems. Conclusions As part of the systems strengthening arsenal, the Tool can stimulate debate about the merits and consequences of different healthcare systems structural designs, using a common framework that fosters multi-country comparative analyses. PMID:28541518

  12. Eco-Systemic Analysis of Anorexia Nervosa.

    ERIC Educational Resources Information Center

    Sheppy, Margarette I.; And Others

    1988-01-01

    Tested eco-systemic approach to understanding of anorexia nervosa. Compared 30 anorexics and parents to 34 matched control subjects and parents. Found that, compared to controls, families of anorexics were less supportive, helpful, and committed to each other. Family interactions perceived by anorexics were characterized by overprotective,…

  13. World Culture in the Capitalist World-System in Transition

    ERIC Educational Resources Information Center

    Griffiths, Tom G.; Arnove, Robert F.

    2015-01-01

    World culture theory (WCT) offers an explanatory framework for macro-level comparative analyses of systems of mass education, including their structures, accompanying policies and their curricular and pedagogical practices. WCT has contributed to broader efforts to overcome methodological nationalism in comparative research. In this paper, we…

  14. Comparative Analysis of Linguists' Professional Training at British and Ukrainian Universities

    ERIC Educational Resources Information Center

    Komochkova, Olga

    2017-01-01

    We have performed comparative analysis on professional training of linguists at British and Ukrainian universities at administrative and managerial, legislative, organizational and pedagogical, systemic, conceptual, socioeconomic levels. As evidenced above, British and Ukrainian systems of professional training of linguists differ significantly,…

  15. Social and economic sustainability of urban systems: comparative analysis of metropolitan statistical areas in Ohio, USA

    EPA Science Inventory

    This article presents a general and versatile methodology for assessing sustainability with Fisher Information as a function of dynamic changes in urban systems. Using robust statistical methods, six Metropolitan Statistical Areas (MSAs) in Ohio were evaluated to comparatively as...

  16. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    NASA Astrophysics Data System (ADS)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  17. Implementation of the Nutrition Care Process and International Dietetics and Nutrition Terminology in a single-center hemodialysis unit: comparing paper vs electronic records.

    PubMed

    Rossi, Megan; Campbell, Katrina Louise; Ferguson, Maree

    2014-01-01

    There is little doubt surrounding the benefits of the Nutrition Care Process and International Dietetics and Nutrition Terminology (IDNT) to dietetics practice; however, evidence to support the most efficient method of incorporating these into practice is lacking. The main objective of our study was to compare the efficiency and effectiveness of an electronic and a manual paper-based system for capturing the Nutrition Care Process and IDNT in a single in-center hemodialysis unit. A cohort of 56 adult patients receiving maintenance hemodialysis were followed for 12 months. During the first 6 months, patients received the usual standard care, with documentation via a manual paper-based system. During the following 6-month period (Months 7 to 12), nutrition care was documented by an electronic system. Workload efficiency, number of IDNT codes used related to nutrition-related diagnoses, interventions, monitoring and evaluation using IDNT, nutritional status using the scored Patient-Generated Subjective Global Assessment Tool of Quality of Life were the main outcome measures. Compared with paper-based documentation of nutrition care, our study demonstrated that an electronic system improved the efficiency of total time spent by the dietitian by 13 minutes per consultation. There were also a greater number of nutrition-related diagnoses resolved using the electronic system compared with the paper-based documentation (P<0.001). In conclusion, the implementation of an electronic system compared with a paper-based system in a population receiving hemodialysis resulted in significant improvements in the efficiency of nutrition care and effectiveness related to patient outcomes. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  18. Comparative evaluation of apically extruded debris during root canal preparation using ProTaper™, Hyflex™ and Waveone™ rotary systems

    PubMed Central

    Surakanti, Jayaprada Reddy; Venkata, Ravi Chandra Polavarapu; Vemisetty, Hari Kumar; Dandolu, Ram Kiran; Jaya, Nagendra Krishna Muppalla; Thota, Shirisha

    2014-01-01

    Background and Aims: Extrusion of any debris during endodontic treatment may potentially cause post-operative complications such as flare-ups. The purpose of this in vitro study was to assess the amount of apically extruded debris during the root canal preparation using rotary and reciprocating nickel-titanium instrumentation systems. Materials and Methods: In this study, 60 human mandibular first premolars were randomly assigned to 3 groups (n = 20 teeth/group). The root canals were instrumented according to the manufacturers’ instructions using the Reciprocating single-file system WaveOne™ (Dentsply Maillefer, Ballaigues, Switzerland) and full-sequence rotary Hyflex CM™ (Coltene Whaledent, Allstetten, Switzerland) and ProTaper™ (Dentsply Maillefer, Ballaigues, Switzerland) instruments. The canals were then irrigated using bidistilled water. The debris that was extruded apically was collected in preweighed eppendorf tubes and assessed with an electronic balance and compared. Statistical Analysis Used: The debris extrusion was compared and statistically analyzed using analysis of variance and the post hoc Student-Newman-Keuls test. Results: The WaveOne™ and ProTaper™ rotary instruments produced significantly more debris compared with Hyflex CM™ rotary instruments (P < 0.05). Conclusions: Under the conditions of this study, all systems that were used resulted in extrusion of apical debris. Full-sequence rotary instrumentation was associated with less debris extrusion compared with the use of reciprocating single-file systems. PMID:24778507

  19. Impact of initiatives to implement science inquiry: a comparative study of the Turkish, Israeli, Swedish and Czech science education systems

    NASA Astrophysics Data System (ADS)

    Heinz, Jana; Enghag, Margareta; Stuchlikova, Iva; Cakmakci, Gultekin; Peleg, Ran; Baram-Tsabari, Ayelet

    2017-09-01

    This empirical study investigates factors that influence the implementation of science inquiry in the education systems of Turkey, Israel, Sweden and the Czech Republic. Data was collected by means of recordings of science experts' discussions as part of an EU-funded project called Science-Teacher Education Advanced Methods (2009-2012). Results of the qualitative analysis reveal that the following general indicators provide insight into the extent of implementation of inquiry-based science education (IBSE): (1) curriculum (2) assessment (3) policy and (4) teacher professionalization systems. In a second step comparative analyses of the four countries' education systems were conducted with regard to these indicators. To compare these factors we refer to both the framework of neo-institutional theories that explore the emergence of isomorphic educational models and to results from comparative studies emphasizing the influence of the countries' individual structure and cultural practices on modifying global pressure to convergence. Results show that in each of the countries these indicators influence the implementation of science inquiry to varying degrees. Moreover, as a result of the comparative analyses further country specific factors important for implementing science inquiry were found: (5) the need to improve existing teaching methods, (6) predominant teaching patterns, (7) infrastructure that enables changes in education and (8) education system's general goals that correlate with reforms.

  20. A comparative study of the Unified System for Orbit Computation and the Flight Design System. [computer programs for mission planning tasks associated with space shuttle

    NASA Technical Reports Server (NTRS)

    Maag, W.

    1977-01-01

    The Flight Design System (FDS) and the Unified System for Orbit Computation (USOC) are compared and described in relation to mission planning for the shuttle transportation system (STS). The FDS is designed to meet the requirements of a standardized production tool and the USOC is designed for rapid generation of particular application programs. The main emphasis in USOC is put on adaptability to new types of missions. It is concluded that a software system having a USOC-like structure, adapted to the specific needs of MPAD, would be appropriate to support planning tasks in the area unique to STS missions.

  1. Application of local binary pattern and human visual Fibonacci texture features for classification different medical images

    NASA Astrophysics Data System (ADS)

    Sanghavi, Foram; Agaian, Sos

    2017-05-01

    The goal of this paper is to (a) test the nuclei based Computer Aided Cancer Detection system using Human Visual based system on the histopathology images and (b) Compare the results of the proposed system with the Local Binary Pattern and modified Fibonacci -p pattern systems. The system performance is evaluated using different parameters such as accuracy, specificity, sensitivity, positive predictive value, and negative predictive value on 251 prostate histopathology images. The accuracy of 96.69% was observed for cancer detection using the proposed human visual based system compared to 87.42% and 94.70% observed for Local Binary patterns and the modified Fibonacci p patterns.

  2. Bi-directional power control system for voltage converter

    DOEpatents

    Garrigan, Neil Richard; King, Robert Dean; Schwartz, James Edward

    1999-01-01

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

  3. Bi-directional power control system for voltage converter

    DOEpatents

    Garrigan, N.R.; King, R.D.; Schwartz, J.E.

    1999-05-11

    A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

  4. Comparison of emerging contaminants in receiving waters downstream of a conventional wastewater treatment plant and a forest-water reuse system.

    PubMed

    McEachran, Andrew D; Hedgespeth, Melanie L; Newton, Seth R; McMahen, Rebecca; Strynar, Mark; Shea, Damian; Nichols, Elizabeth Guthrie

    2018-05-01

    Forest-water reuse (FWR) systems treat municipal, industrial, and agricultural wastewaters via land application to forest soils. Previous studies have shown that both large-scale conventional wastewater treatment plants (WWTPs) and FWR systems do not completely remove many contaminants of emerging concern (CECs) before release of treated wastewater. To better characterize CECs and potential for increased implementation of FWR systems, FWR systems need to be directly compared to conventional WWTPs. In this study, both a quantitative, targeted analysis and a nontargeted analysis were utilized to better understand how CECs release to waterways from an FWR system compared to a conventional treatment system. Quantitatively, greater concentrations and total mass load of CECs was exhibited downstream of the conventional WWTP compared to the FWR. Average summed concentrations of 33 targeted CECs downstream of the conventional system were ~ 1000 ng/L and downstream of the FWR were ~ 30 ng/L. From a nontargeted chemical standpoint, more tentatively identified chemicals were present, and at a greater relative abundance, downstream of the conventional system as well. Frequently occurring contaminants included phthalates, pharmaceuticals, and industrial chemicals. These data indicate that FWR systems represent a sustainable wastewater treatment alternative and that emerging contaminant release to waterways was lower at a FWR system than a conventional WWTP.

  5. Infant CPAP for low-income countries: An experimental comparison of standard bubble CPAP and the Pumani system.

    PubMed

    Falk, Markus; Donaldsson, Snorri; Drevhammar, Thomas

    2018-01-01

    Access to inexpensive respiratory support to newborn infants improves survival in low-income countries. Standard bubble continuous positive airway pressure (CPAP) has been extensively used worldwide for more than 30 years. One project aimed at providing affordable CPAP is the Pumani system developed by Rice 360°. Compared to standard bubble CPAP the system has an unconventional design. The aim was to compare the Pumani system with two traditional bubble CPAP systems, focusing on in-vitro performance and safety. The Pumani system was compared to traditional bubble CPAP from Fisher & Paykel (Auckland, New Zealand) and Diamedica (Devon, United Kingdom). The systems were tested using static flow resistance and simulated breathing for a range of fresh gas flows and submersion levels. There were large differences between the Pumani CPAP and the conventional bubble CPAP systems. The Pumani system was not pressure stable, had high resistance and high imposed work of breathing. It was not possible to use submersion depth to adjust CPAP without accounting for fresh gas flow. The Pumani design is novel and not similar to any previously described CPAP system. The main mechanism for CPAP generation was resistance, not submersion depth. The system should therefore not be referred to as bubble CPAP. The clinical consequences of its pressure instability and high imposed work of breathing are not known and trials on outcome and safety are needed.

  6. Cost analysis of an ammonia dry cooling system with a Chicago Bridge and Iron peak shaving system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drost, M.K.; Johnson, B.M.

    1980-12-01

    A study was performed to determine the potential for reducing the cost associated with dry cooling by using an ammonia dry cooling system augmented with the Chicago Bridge and Iron (CP and I) peak shaving system. The cost analysis of an all-dry ammonia cooling system operating in conjunction with a peak shaving system is documented. The peak shaving system utilizes the excess cooling capability available at night to cool water to be used for supplemental cooling during the following day. The analysis consisted of determining the incremental cost of cooling for the CB and I system and comparing this costmore » to the incremental cost of cooling for both dry and wet/dry systems for a consistent set of design conditions and assumptions. The wet/dry systems were analyzed over a range of water usages. The basis of the comparisons was a cooling system designed for installations with a 650 mWe (gross) coal-fired power plant. From results of the study it was concluded that: the CB and I system shows a substantial economic advantage when compared with an all-dry cooling system; the CB and I system appears to be competitive with wet/dry cooling systems using about 2 to 3% water; and the CB and I system demonstrates a clear economic advantage when compared to both dry and wet/dry concepts for a winter peaking utility where the excess generation is assumed to displace both base-loaded coal-fired power generation and oil-fired gas turbine peaking units.« less

  7. Performance evaluation of molten salt thermal storage systems

    NASA Astrophysics Data System (ADS)

    Kolb, G. J.; Nikolai, U.

    1987-09-01

    The molton salt thermal storage system located at the Central Receiver Test Facility (CRTF) was recently subjected to thermal performance tests. The system is composed of a hot storage tank containing molten nitrate salt at a temperature of 1050 F and a cold tank containing 550 F salt with associated valves and controls. It is rated at 7 MWht and was designed and installed by Martin Marietta Corporation in 1982. The results of these tests were used to accomplish four objectives: (1) to compare the current thermal performance of the system with the performance of the system soon after it was installed, (2) to validate a dynamic computer model of the system, (3) to obtain an estimate of an annual system efficiency for a hypothetical commercial scale 1200 MWht system and (4) to compare the performance of the CRTF system with thermal storage systems developed by the European solar community.

  8. Choice of optical system is critical for the security of double random phase encryption systems

    NASA Astrophysics Data System (ADS)

    Muniraj, Inbarasan; Guo, Changliang; Malallah, Ra'ed; Cassidy, Derek; Zhao, Liang; Ryle, James P.; Healy, John J.; Sheridan, John T.

    2017-06-01

    The linear canonical transform (LCT) is used in modeling a coherent light-field propagation through first-order optical systems. Recently, a generic optical system, known as the quadratic phase encoding system (QPES), for encrypting a two-dimensional image has been reported. In such systems, two random phase keys and the individual LCT parameters (α,β,γ) serve as secret keys of the cryptosystem. It is important that such encryption systems also satisfy some dynamic security properties. We, therefore, examine such systems using two cryptographic evaluation methods, the avalanche effect and bit independence criterion, which indicate the degree of security of the cryptographic algorithms using QPES. We compared our simulation results with the conventional Fourier and the Fresnel transform-based double random phase encryption (DRPE) systems. The results show that the LCT-based DRPE has an excellent avalanche and bit independence characteristics compared to the conventional Fourier and Fresnel-based encryption systems.

  9. An Empirical Analysis of Negotiation Teaching Methodologies Using a Negotiation Support System

    ERIC Educational Resources Information Center

    Jones, Beth H.; Jones, Gary H.; Banerjee, Debasish

    2005-01-01

    This article describes an experiment that compared different methods of teaching undergraduates the fundamentals of negotiation analysis. Using student subjects, we compared three conditions: reading, lecture-only, and lecture accompanied by student use of a computerized negotiation support system (NSS). The authors examined two facets of…

  10. Comparative Survey of Drug Use in a Community Service System.

    ERIC Educational Resources Information Center

    Zaharia, E. S.; Struxness, L.

    1991-01-01

    Drug use patterns were surveyed in Colorado's community services system for 1,282 individuals with developmental disabilities. A psychotropic drug use rate of 18.6 percent compared favorably to other reported rates and rates in Colorado's institutional settings. Substantial experience with psychotropic and anticonvulsant medications across all…

  11. The legibility of the Clearview typeface system versus standard highway alphabets on negative- and positive-contrast signs.

    DOT National Transportation Integrated Search

    2015-02-01

    The main objective of this research was to compare the legibility distance of the negative-contrast (i.e., darker letters on a lighter : background) Clearview Typeface System with that of comparable Standard Highway Alphabets on black-on-white signs ...

  12. A comparative study of electric power distribution systems for spacecraft

    NASA Technical Reports Server (NTRS)

    Stuart, Thomas A.; King, Roger J.

    1990-01-01

    The electric power distribution systems for spacecraft are compared concentrating on two interrelated issues: the choice between dc and high frequency ac, and the converter/inverter topology to be used at the power source. The relative merits of dc and ac distribution are discussed. Specific converter and inverter topologies are identified and analyzed in detail for the purpose of detailed comparison. Finally, specific topologies are recommended for use in dc and ac systems.

  13. Removal of organic wastewater contaminants in septic systems using advanced treatment technologies

    USGS Publications Warehouse

    Wilcox, J.D.; Bahr, J.M.; Hedman, C.J.; Hemming, J.D.C.; Barman, M.A.E.; Bradbury, K.R.

    2009-01-01

    The detection of pharmaceuticals and other organic wastewater contaminants (OWCs) in ground water and surface-water bodies has raised concerns about the possible ecological impacts of these compounds on nontarget organisms. On-site wastewater treatment systems represent a potentially significant route of entry for organic contaminants to the environment. In this study, effluent samples were collected and analyzed from conventional septic systems and from systems using advanced treatment technologies. Six of 13 target compounds were detected in effluent from at least one septic system. Caffeine, paraxanthine, and acetaminophen were the most frequently detected compounds, and estrogenic activity was detected in 14 of 15 systems. The OWC concentrations were significantly lower in effluent after sand filtration (p < 0.01) or aerobic treatment (p < 0.05) as compared with effluent that had not undergone advanced treatment. In general, concentrations in conventional systems were comparable to those measured in previous studies of municipal wastewater treatment plant (WWTP) influent, and concentrations in systems after advanced treatment were comparable to previously measured concentrations in WWTP effluent. These data indicate that septic systems using advanced treatment can reduce OWCs in treated effluent to similar concentrations as municipal WWTPs. Copyright ?? 2009 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  14. GPU based cloud system for high-performance arrhythmia detection with parallel k-NN algorithm.

    PubMed

    Tae Joon Jun; Hyun Ji Park; Hyuk Yoo; Young-Hak Kim; Daeyoung Kim

    2016-08-01

    In this paper, we propose an GPU based Cloud system for high-performance arrhythmia detection. Pan-Tompkins algorithm is used for QRS detection and we optimized beat classification algorithm with K-Nearest Neighbor (K-NN). To support high performance beat classification on the system, we parallelized beat classification algorithm with CUDA to execute the algorithm on virtualized GPU devices on the Cloud system. MIT-BIH Arrhythmia database is used for validation of the algorithm. The system achieved about 93.5% of detection rate which is comparable to previous researches while our algorithm shows 2.5 times faster execution time compared to CPU only detection algorithm.

  15. HRV based health&sport markers using video from the face.

    PubMed

    Capdevila, Lluis; Moreno, Jordi; Movellan, Javier; Parrado, Eva; Ramos-Castro, Juan

    2012-01-01

    Heart Rate Variability (HRV) is an indicator of health status in the general population and of adaptation to stress in athletes. In this paper we compare the performance of two systems to measure HRV: (1) A commercial system based on recording the physiological cardiac signal with (2) A computer vision system that uses a standard video images of the face to estimate RR from changes in skin color of the face. We show that the computer vision system performs surprisingly well. It estimates individual RR intervals in a non-invasive manner and with error levels comparable to those achieved by the physiological based system.

  16. Comparisons of Health Care Systems in the United States, Germany and Canada

    PubMed Central

    Ridic, Goran; Gleason, Suzanne; Ridic, Ognjen

    2012-01-01

    The purpose of this research paper is to compare health care systems in three highly advanced industrialized countries: The United States of America, Canada and Germany. The first part of the research paper will focus on the description of health care systems in the above-mentioned countries while the second part will analyze, evaluate and compare the three systems regarding equity and efficiency. Finally, an overview of recent changes and proposed future reforms in these countries will be provided as well. We start by providing a general description and comparison of the structure of health care systems in Canada, Germany and the United States. PMID:23678317

  17. On board processing for future satellite communications systems: Comparison of FDM, TDM and hybrid accessing schemes

    NASA Technical Reports Server (NTRS)

    Berk, G.; Jean, P. N.; Rotholz, E.

    1982-01-01

    Several satellite uplink and downlink accessing schemes for customer premises service are compared. Four conceptual system designs are presented: satellite-routed frequency division multiple access (FDMA), satellite-switched time division multiple access (TDMA), processor-routed TDMA, and frequency-routed TDMA, operating in the 30/20 GHz band. The designs are compared on the basis of estimated satellite weight, system capacity, power consumption, and cost. The systems are analyzed for fixed multibeam coverage of the continental United States. Analysis shows that the system capacity is limited by the available satellite resources and by the terminal size and cost.

  18. The use of multi criteria analysis to compare the operating scenarios of the hybrid generation system of wind turbines, photovoltaic modules and a fuel cell

    NASA Astrophysics Data System (ADS)

    Ceran, Bartosz

    2017-11-01

    The paper presents the results of the use of multi-criteria analysis to compare hybrid power generation system collaboration scenarios (HSW) consisting of wind turbines, solar panels and energy storage electrolyzer - PEM type fuel cell with electricity system. The following scenarios were examined: the base S-I-hybrid system powers the off-grid mode receiver, S-II, S-III, S-IV scenarios-electricity system covers 25%, 50%, 75% of energy demand by the recipient. The effect of weights of the above-mentioned criteria on the final result of the multi-criteria analysis was examined.

  19. Prognostic scoring systems for myelodysplastic syndromes (MDS) in a population-based setting: a report from the Swedish MDS register.

    PubMed

    Moreno Berggren, Daniel; Folkvaljon, Yasin; Engvall, Marie; Sundberg, Johan; Lambe, Mats; Antunovic, Petar; Garelius, Hege; Lorenz, Fryderyk; Nilsson, Lars; Rasmussen, Bengt; Lehmann, Sören; Hellström-Lindberg, Eva; Jädersten, Martin; Ejerblad, Elisabeth

    2018-06-01

    The myelodysplastic syndromes (MDS) have highly variable outcomes and prognostic scoring systems are important tools for risk assessment and to guide therapeutic decisions. However, few population-based studies have compared the value of the different scoring systems. With data from the nationwide Swedish population-based MDS register we validated the International Prognostic Scoring System (IPSS), revised IPSS (IPSS-R) and the World Health Organization (WHO) Classification-based Prognostic Scoring System (WPSS). We also present population-based data on incidence, clinical characteristics including detailed cytogenetics and outcome from the register. The study encompassed 1329 patients reported to the register between 2009 and 2013, 14% of these had therapy-related MDS (t-MDS). Based on the MDS register, the yearly crude incidence of MDS in Sweden was 2·9 per 100 000 inhabitants. IPSS-R had a significantly better prognostic power than IPSS (P < 0·001). There was a trend for better prognostic power of IPSS-R compared to WPSS (P = 0·05) and for WPSS compared to IPSS (P = 0·07). IPSS-R was superior to both IPSS and WPSS for patients aged ≤70 years. Patients with t-MDS had a worse outcome compared to de novo MDS (d-MDS), however, the validity of the prognostic scoring systems was comparable for d-MDS and t-MDS. In conclusion, population-based studies are important to validate prognostic scores in a 'real-world' setting. In our nationwide cohort, the IPSS-R showed the best predictive power. © 2018 John Wiley & Sons Ltd.

  20. Comparative genome analysis in the integrated microbial genomes (IMG) system.

    PubMed

    Markowitz, Victor M; Kyrpides, Nikos C

    2007-01-01

    Comparative genome analysis is critical for the effective exploration of a rapidly growing number of complete and draft sequences for microbial genomes. The Integrated Microbial Genomes (IMG) system (img.jgi.doe.gov) has been developed as a community resource that provides support for comparative analysis of microbial genomes in an integrated context. IMG allows users to navigate the multidimensional microbial genome data space and focus their analysis on a subset of genes, genomes, and functions of interest. IMG provides graphical viewers, summaries, and occurrence profile tools for comparing genes, pathways, and functions (terms) across specific genomes. Genes can be further examined using gene neighborhoods and compared with sequence alignment tools.

  1. Quantitative assessments of municipal waste management systems: using different indicators to compare and rank programs in New York State.

    PubMed

    Greene, Krista L; Tonjes, David J

    2014-04-01

    The primary objective of waste management technologies and policies in the United States is to reduce the harmful environmental impacts of waste, particularly those relating to energy consumption and climate change. Performance indicators are frequently used to evaluate the environmental quality of municipal waste systems, as well as to compare and rank programs relative to each other in terms of environmental performance. However, there currently is no consensus on the best indicator for performing these environmental evaluations. The purpose of this study is to examine the common performance indicators used to assess the environmental benefits of municipal waste systems to determine if there is agreement between them regarding which system performs best environmentally. Focus is placed on how indicator selection influences comparisons between municipal waste management programs and subsequent system rankings. The waste systems of ten municipalities in the state of New York, USA, were evaluated using each common performance indicator and Spearman correlations were calculated to see if there was a significant association between system rank orderings. Analyses showed that rank orders of waste systems differ substantially when different indicators are used. Therefore, comparative system assessments based on indicators should be considered carefully, especially those intended to gauge environmental quality. Insight was also gained into specific factors which may lead to one system achieving higher rankings than another. However, despite the insufficiencies of indicators for comparative quality assessments, they do provide important information for waste managers and they can assist in evaluating internal programmatic performance and progress. To enhance these types of assessments, a framework for scoring indicators based on criteria that evaluate their utility and value for system evaluations was developed. This framework was used to construct an improved model for waste system performance assessments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Extracorporeal continuous portal diversion plus temporal plasmapheresis for “small-for-size” syndrome

    PubMed Central

    Hou, Peng; Chen, Chao; Tu, Yu-Liang; Zhu, Zi-Man; Tan, Jing-Wang

    2013-01-01

    AIM: To investigate the effect of plasmapheresis via the portal vein for “small-for-size” syndrome (SFSS) aided by extracorporeal continuous portal diversion (ECPD). METHODS: Extensive or total hepatectomy in the pig is usually adopted as a postoperative liver failure (PLF) or SFSS model. In this study, animals which underwent 85%-90% hepatectomy were randomized into either the Systemic group (n = 7) or the Portal group (n = 7). In the Systemic group, all pigs received temporal plasmapheresis (PP) via the extracorporeal catheter circuit (systemic to systemic circulation) from 24 to 30 h post-hepatectomy (PH); in the Portal group, all pigs received ECPD to divert partial portal vein flow (PVF) to the systemic circulation after hepatectomy, then converted to temporal PP from 24 to 30 h PH, and subsequently converted to ECPD again until 48 h PH. In the Portal group, the PVF was preserved at 3.0-3.3 times that of the baseline value, similar to that following 70% hepatectomy, which was regarded as the optimal PVF to the hypertrophic liver remnant. At 48 h PH, all pigs were re-opened and the portal vein pressure (PVP), PVF, and HAF (hepatic artery flow) were measured, and then diversion of the portal venous flow was terminated. After 1 h the PVP, PVF, and HAF were re-measured. The portal hemodynamic changes, liver injury, liver regeneration and bacterial/lipopolysaccharide (LPS) translocation were evaluated in the two groups. RESULTS: The PVP in the Portal group was significantly lower than that in the Systemic group during the time period from 2 to 49 h PH (P < 0.05). Serum alanine aminotransferase (ALT), total bilirubin (TB) and ammonia were significantly reduced in the Portal group compared with the Systemic group from 24 to 48 h PH (P < 0.05). The Portal group may have attenuated sinusoidal endothelial injury and decreased the level of HA compared with the Systemic group. In the Systemic group, there was significant sinusoidal dilation, hydropic changes in hepatocytes and hemorrhage into the hepatic parenchyma, and the sinusoidal endothelial lining was partially destroyed and detached into the sinusoidal space. CD31 immunostaining revealed significant destruction of the endothelial lining. In the Portal group, there was no intraparenchymal hemorrhage and the sinusoidal endothelial cells and hepatocytes were well preserved. CD31 immunostaining was mild which indicated less destruction of the endothelial lining. HA was significantly decreased in the Portal group compared with the Systemic group from 2 to 48 h PH. The rate of liver remnant regeneration was elevated, while apoptosis was attenuated in the Portal group compared with the Systemic group. Thymidine kinase activity was much higher in the Portal group than in the Systemic group at 48 h PH. The PCNA index was significantly increased and the apoptotic index was significantly decreased in the Portal group compared with the Systemic group. Bacterial translocation and endotoxin, as well as the inflammatory response, were significantly attenuated in the Portal group compared with the Systemic group. LPS, tumor necrosis factor-α and interleukin-6 levels were all significantly decreased in the Portal group compared with the Systemic group from 24 to 48 h PH, while bacterial DNA level was significantly decreased from 2 to 48 h PH. CONCLUSION: PP plus ECPD via the portal vein can attenuate toxic load and hyperperfusion injury, and should be undertaken instead of PP via the systemic circulation in SFSS or PLF. PMID:24023489

  3. A Limited Rotary-Wing Flight Investigation of Hyperstereo in Helmet-Mounted Display Designs

    DTIC Science & Technology

    2009-07-01

    when compared to current and near-term I2 systems with a direct optical linkage. In summary, the current binocular I2 HMD design of ANVIS, which...terms of visual and optical performance. This assessment was performed by measuring a number of system parameters and by comparing the obtained...to subject #2 who had 800 NVG flight hours. Interestingly, across all maneuvers for which the hyperstereo HMD was asked to be compared to ANVIS

  4. An Approach to the Comparative Analysis of the US and Soviet Economies.

    DTIC Science & Technology

    1980-09-01

    compare aithority exer:isud in different forms is hasic. Designing such a i,,easuring system necessitates development of a weighting system to measure the...Proper flie maintenance is diffi,.lt 34 a because of poor file organization, inade;tiately designed inflow of updating information, and manual methods...asiSsnet 5.1 Issues Areas for Comparative Analysis Comparativ ,. issioes relatc to i, soc-cicty’s mobjilization of resources and use of institution’, Lo a

  5. A Comparative Analysis of Meeting the Whole Child Initiatives through Standardized and Competency-Based Education Systems in Terms of Achievement and Meeting the Whole Child Initiatives: Comparing Professional Perceptions and Identified Measurable Results

    ERIC Educational Resources Information Center

    Ward, Jacqueline M.

    2011-01-01

    Traditional education (TE) largely uses a standardized (SbE) approach while alternatives (nTE) tend to more of a competency (CbE), or student-centered approach. This comparative analysis examines essential aspects of such pedagogies in determining the effectiveness of schooling systems in meeting the Whole Child Initiative (Souza, 1999; Carter et…

  6. Randomized trial of four-layer and two-layer bandage systems in the management of chronic venous ulceration.

    PubMed

    Moffatt, Christine J; McCullagh, Lynn; O'Connor, Theresa; Doherty, Debra C; Hourican, Catherine; Stevens, Julie; Mole, Trevor; Franks, Peter J

    2003-01-01

    To compare a four-layer bandage system with a two-layer system in the management of chronic venous leg ulceration, a prospective randomized open parallel groups trial was undertaken. In total, 112 patients newly presenting to leg ulcer services with chronic leg ulceration, screened to exclude the presence of arterial disease (ankle brachial pressure index <0.8) and causes of ulceration other than venous disease, were entered into the trial. Patients were randomized to receive either four-layer (Profore) or two-layer (Surepress) high-compression elastic bandage systems. In all, 109 out of 112 patients had at least one follow-up. After 24 weeks, 50 out of 57 (88%) patients randomized to the four-layer bandage system with follow-up had ulcer closure (full epithelialization) compared with 40 out of 52 (77%) on the two-layer bandage, hazard ratio = 1.18 (95% confidence interval 0.69-2.02), p = 0.55. After 12 weeks, 40 out of 57 (70%) patients randomized to the four-layer bandage system with follow-up had ulcer closure compared with 30 out of 52 (58%) on the two-layer bandage, odds ratio = 4.23 (95% confidence interval 1.29-13.86), p = 0.02. Withdrawal rates were significantly greater on the two-layer bandage (30 out of 54; 56%) compared with the four-layer bandage system (8 out of 58; 14%), p < 0.001, and the number of patients with at least one device-related adverse incident was significantly greater on the two-layer bandaging system (15 out of 54; 28%) compared with four-layer bandaging (5 out of 54; 9%), p = 0.01. The higher mean cost of treatment in the two-layer bandaging system arm over 24 weeks ($1374 [ pound 916] vs. $1314 [ pound 876]) was explained by the increased mean number of bandage changes (1.5 vs. 1.1 per week) with the two-layer system. In conclusion, the four-layer bandage offers advantages over the two-layer bandage in terms of reduced withdrawal from treatment, fewer adverse incidents, and lower treatment cost.

  7. Network Flow Simulation of Fluid Transients in Rocket Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Bandyopadhyay, Alak; Hamill, Brian; Ramachandran, Narayanan; Majumdar, Alok

    2011-01-01

    Fluid transients, also known as water hammer, can have a significant impact on the design and operation of both spacecraft and launch vehicle propulsion systems. These transients often occur at system activation and shutdown. The pressure rise due to sudden opening and closing of valves of propulsion feed lines can cause serious damage during activation and shutdown of propulsion systems. During activation (valve opening) and shutdown (valve closing), pressure surges must be predicted accurately to ensure structural integrity of the propulsion system fluid network. In the current work, a network flow simulation software (Generalized Fluid System Simulation Program) based on Finite Volume Method has been used to predict the pressure surges in the feed line due to both valve closing and valve opening using two separate geometrical configurations. The valve opening pressure surge results are compared with experimental data available in the literature and the numerical results compared very well within reasonable accuracy (< 5%) for a wide range of inlet-to-initial pressure ratios. A Fast Fourier Transform is preformed on the pressure oscillations to predict the various modal frequencies of the pressure wave. The shutdown problem, i.e. valve closing problem, the simulation results are compared with the results of Method of Characteristics. Most rocket engines experience a longitudinal acceleration, known as "pogo" during the later stage of engine burn. In the shutdown example problem, an accumulator has been used in the feed system to demonstrate the "pogo" mitigation effects in the feed system of propellant. The simulation results using GFSSP compared very well with the results of Method of Characteristics.

  8. Comparative distribution of pilocarpine in ocular tissues of the rabbit during administration by eyedrop or by membrane-controlled delivery systems.

    PubMed

    Sendelbeck, L; Moore, D; Urquhart, J

    1975-08-01

    We compared the patterns of pilocarpine distribution in the rabbit eye during two regimens that were comparably efficacious in human clinical use: an administration of 2% pilocarpine nitrate eyedrops, every six hours, for four and eight days, and a continuous delivery of pilocarpine for as long as eight days, at 20 mug/hr, from a membrane-controlled delivery system in the inferior cul-de-sac. Pilocarpine labeled with radioactive carbon (14C) was used as a tracer. With administration of eyedrops, 14C levels in ocular tissues rose and fell within each six-hour interval between eyedrops, but with the delivery system, 14C levels remained constant over the two- to eight-day period. In each tissue, the 14C level within the first hour after the most recently administered eyedrop always exceeded the constant level maintained by the delivery system. Three to six hours after eyedrop administration, the 14C levels in cornea, iris, and sclera were approximately equal to those maintained by the delivery system. However, in lens, vitreous humor, and conjunctiva, the 14C levels were always two to five times higher with eyedrop administration than with the delivery system. Only aqueous humor showed a significantly lower 14C level with eyedrops than with the delivery system, occurring late in the interval between eyedrops. Compared to eyedrop administration, the membrane-controlled delivery system produced drug levels in ocular tissues that were constant rather than variable with time, and appreciably lower in tissues where the drug made no known contribution to the reduction of pressure.

  9. WITHDRAWN: Systemic treatments for metastatic cutaneous melanoma.

    PubMed

    Crosby, Tom; Fish, Reg; Coles, Bernadette; Mason, Malcolm

    2018-02-07

    Systemic therapies for metastatic cutaneous melanoma, the most aggressive of all skin cancers, remain disappointing. Few lasting remissions are achieved and the therapeutic aim remains one of palliation.Many agents are used alone or in combination with varying degrees of toxicity and cost. It is unclear whether evidence exists to support these complex regimens over best supportive care / placebo. To review the benefits from the use of systemic therapies in metastatic cutaneous melanoma compared to best supportive care/placebo, and to establish whether a 'standard' therapy exists which is superior to other treatments. Randomised controlled trials were identified from the MEDLINE, EMBASE and CCTR/CENTRAL databases. References, conference proceedings, and Science Citation Index/Scisearch were also used to locate trials. Cancer registries and trialists were also contacted. Randomised controlled trials of adults with histologically proven metastatic cutaneous melanoma in which systemic anti-cancer therapy was compared with placebo or supportive care. Study selection was performed by two independent reviewers. Data extraction forms were used for studies which appeared to meet the selection criteria and, where appropriate, full text articles were retrieved and reviewed independently. No randomised controlled trials were found comparing a systemic therapy with placebo or best supportive care in metastatic cutaneous melanoma. There is no evidence from randomised controlled clinical trials to show superiority of systemic therapy over best supportive care / placebo in the treatment of malignant cutaneous melanoma.Given that patients with metastatic melanoma frequently receive systemic therapy, it is our pragmatic view that a future systematic review could compare any systemic treatment, or combination of treatments, to single agent dacarbazine.

  10. Lung density change after SABR: A comparative study between tri-Co-60 magnetic resonance-guided system and linear accelerator

    PubMed Central

    Kim, Eunji; Wu, Hong-Gyun; Park, Jong Min; Kim, Jung-in; Kim, Hak Jae

    2018-01-01

    Radiation-induced lung damage is an important treatment-related toxicity after lung stereotactic ablative radiotherapy (SABR). After implementing a tri-60Co magnetic-resonance image guided system, ViewRayTM, we compared the associated early radiological lung density changes to those associated with a linear accelerator (LINAC). Eight patients treated with the tri-60Co system were matched 1:1 with patients treated with LINAC. Prescription doses were 52 Gy or 60 Gy in four fractions, and lung dose-volumetric parameters were calculated from each planning system. The first two follow-up computed tomography (CT) were co-registered with the planning CT through deformable registration software, and lung density was measured by isodose levels. Tumor size was matched between the two groups, but the planning target volume of LINAC was larger than that of the tri-60Co system (p = 0.036). With regard to clinically relevant dose-volumetric parameters in the lungs, the ipsilateral lung mean dose, V10Gy and V20Gy were significantly poorer in tri-60Co plans compared to LINAC plans (p = 0.012, 0.036, and 0.017, respectively). Increased lung density was not observed in the first follow-up scan compared to the planning scan. A significant change of lung density was shown in the second follow-up scan and there was no meaningful difference between the tri-60Co system and LINAC for all dose regions. In addition, no patient developed clinical radiation pneumonitis until the second follow-up scan. Therefore, there was no significant difference in the early radiological lung damage between the tri-60Co system and LINAC for lung SABR despite of the inferior plan quality of the tri-60Co system compared to that of LINAC. Further studies with a longer follow-up period are needed to confirm our findings. PMID:29608606

  11. Microgap Evaluation of Novel Hydrophilic and Hydrophobic Obturating System: A Scanning Electron Microscope Study.

    PubMed

    Hegde, Vibha; Murkey, Laxmi Suresh

    2017-05-01

    The purpose of an endodontic obturation is to obtain a fluid tight hermetic seal of the entire root canal system. There has been an evolution of different materials and techniques to achieve this desired gap free fluid tight seal due to presence of anatomic complexity of the root canal system. To compare the microgap occurring in root canals obturated with hydrophilic versus hydrophobic systems using scanning electron microscope. Sixty extracted human single-rooted premolars were decoronated, instrumented using NiTi rotary instruments. The samples (n=20) were divided into three groups and obturated with Group A - (control group) gutta-percha with AH Plus, Group B - C-point with Smartpaste Bio and Group C - gutta-percha with guttaflow 2. The samples were split longitudinally into two halves and microgap was observed under scanning electron microscope in the apical 3 mm of the root canal. Group A (control) showed a mean difference of 8.54 as compared to 5.76 in group C. Group B showed the lowest mean difference of 0.83 suggesting that the hydrophilic system (C-point/Smartpaste Bio) produced least microgap as compared to the hydrophobic groups. Novel hydrophilic obturating system (C-points/ Smart-paste Bio) showed better seal and least microgap as compared to gutta-percha/guttaflow 2 and gutta-percha/ AH plus which showed gap at the sealer dentin interface due to less penetration and bonding of these hydrophobic obturating system.

  12. System matrix computation vs storage on GPU: A comparative study in cone beam CT.

    PubMed

    Matenine, Dmitri; Côté, Geoffroi; Mascolo-Fortin, Julia; Goussard, Yves; Després, Philippe

    2018-02-01

    Iterative reconstruction algorithms in computed tomography (CT) require a fast method for computing the intersection distances between the trajectories of photons and the object, also called ray tracing or system matrix computation. This work focused on the thin-ray model is aimed at comparing different system matrix handling strategies using graphical processing units (GPUs). In this work, the system matrix is modeled by thin rays intersecting a regular grid of box-shaped voxels, known to be an accurate representation of the forward projection operator in CT. However, an uncompressed system matrix exceeds the random access memory (RAM) capacities of typical computers by one order of magnitude or more. Considering the RAM limitations of GPU hardware, several system matrix handling methods were compared: full storage of a compressed system matrix, on-the-fly computation of its coefficients, and partial storage of the system matrix with partial on-the-fly computation. These methods were tested on geometries mimicking a cone beam CT (CBCT) acquisition of a human head. Execution times of three routines of interest were compared: forward projection, backprojection, and ordered-subsets convex (OSC) iteration. A fully stored system matrix yielded the shortest backprojection and OSC iteration times, with a 1.52× acceleration for OSC when compared to the on-the-fly approach. Nevertheless, the maximum problem size was bound by the available GPU RAM and geometrical symmetries. On-the-fly coefficient computation did not require symmetries and was shown to be the fastest for forward projection. It also offered reasonable execution times of about 176.4 ms per view per OSC iteration for a detector of 512 × 448 pixels and a volume of 384 3 voxels, using commodity GPU hardware. Partial system matrix storage has shown a performance similar to the on-the-fly approach, while still relying on symmetries. Partial system matrix storage was shown to yield the lowest relative performance. On-the-fly ray tracing was shown to be the most flexible method, yielding reasonable execution times. A fully stored system matrix allowed for the lowest backprojection and OSC iteration times and may be of interest for certain performance-oriented applications. © 2017 American Association of Physicists in Medicine.

  13. Evaluating maturation and genetic modification of human dendritic cells in a new polyolefin cell culture bag system.

    PubMed

    Macke, Lars; Garritsen, Henk S P; Meyring, Wilhelm; Hannig, Horst; Pägelow, Ute; Wörmann, Bernhard; Piechaczek, Christoph; Geffers, Robert; Rohde, Manfred; Lindenmaier, Werner; Dittmar, Kurt E J

    2010-04-01

    Dendritic cells (DCs) are applied worldwide in several clinical studies of immune therapy of malignancies, autoimmune diseases, and transplantations. Most legislative bodies are demanding high standards for cultivation and transduction of cells. Closed-cell cultivating systems like cell culture bags would simplify and greatly improve the ability to reach these cultivation standards. We investigated if a new polyolefin cell culture bag enables maturation and adenoviral modification of human DCs in a closed system and compare the results with standard polystyrene flasks. Mononuclear cells were isolated from HLA-A*0201-positive blood donors by leukapheresis. A commercially available separation system (CliniMACS, Miltenyi Biotec) was used to isolate monocytes by positive selection using CD14-specific immunomagnetic beads. The essentially homogenous starting cell population was cultivated in the presence of granulocyte-macrophage-colony-stimulating factor and interleukin-4 in a closed-bag system in parallel to the standard flask cultivation system. Genetic modification was performed on Day 4. After induction of maturation on Day 5, mature DCs could be harvested and cryopreserved on Day 7. During the cultivation period comparative quality control was performed using flow cytometry, gene expression profiling, and functional assays. Both flasks and bags generated mature genetically modified DCs in similar yields. Surface membrane markers, expression profiles, and functional testing results were comparable. The use of a closed-bag system facilitated clinical applicability of genetically modified DCs. The polyolefin bag-based culture system yields DCs qualitatively and quantitatively comparable to the standard flask preparation. All steps including cryopreservation can be performed in a closed system facilitating standardized, safe, and reproducible preparation of therapeutic cells.

  14. NOBLE - Flexible concept recognition for large-scale biomedical natural language processing.

    PubMed

    Tseytlin, Eugene; Mitchell, Kevin; Legowski, Elizabeth; Corrigan, Julia; Chavan, Girish; Jacobson, Rebecca S

    2016-01-14

    Natural language processing (NLP) applications are increasingly important in biomedical data analysis, knowledge engineering, and decision support. Concept recognition is an important component task for NLP pipelines, and can be either general-purpose or domain-specific. We describe a novel, flexible, and general-purpose concept recognition component for NLP pipelines, and compare its speed and accuracy against five commonly used alternatives on both a biological and clinical corpus. NOBLE Coder implements a general algorithm for matching terms to concepts from an arbitrary vocabulary set. The system's matching options can be configured individually or in combination to yield specific system behavior for a variety of NLP tasks. The software is open source, freely available, and easily integrated into UIMA or GATE. We benchmarked speed and accuracy of the system against the CRAFT and ShARe corpora as reference standards and compared it to MMTx, MGrep, Concept Mapper, cTAKES Dictionary Lookup Annotator, and cTAKES Fast Dictionary Lookup Annotator. We describe key advantages of the NOBLE Coder system and associated tools, including its greedy algorithm, configurable matching strategies, and multiple terminology input formats. These features provide unique functionality when compared with existing alternatives, including state-of-the-art systems. On two benchmarking tasks, NOBLE's performance exceeded commonly used alternatives, performing almost as well as the most advanced systems. Error analysis revealed differences in error profiles among systems. NOBLE Coder is comparable to other widely used concept recognition systems in terms of accuracy and speed. Advantages of NOBLE Coder include its interactive terminology builder tool, ease of configuration, and adaptability to various domains and tasks. NOBLE provides a term-to-concept matching system suitable for general concept recognition in biomedical NLP pipelines.

  15. Acquiring research-grade ERPs on a shoestring budget: A comparison of a modified Emotiv and commercial SynAmps EEG system.

    PubMed

    Barham, Michael P; Clark, Gillian M; Hayden, Melissa J; Enticott, Peter G; Conduit, Russell; Lum, Jarrad A G

    2017-09-01

    This study compared the performance of a low-cost wireless EEG system to a research-grade EEG system on an auditory oddball task designed to elicit N200 and P300 ERP components. Participants were 15 healthy adults (6 female) aged between 19 and 40 (M = 28.56; SD = 6.38). An auditory oddball task was presented comprising 1,200 presentations of a standard tone interspersed by 300 trials comprising a deviant tone. EEG was simultaneously recorded from a modified Emotiv EPOC and a NeuroScan SynAmps RT EEG system. The modifications made to the Emotiv system included attaching research grade electrodes to the Bluetooth transmitter. Additional modifications enabled the Emotiv system to connect to a portable impedance meter. The cost of these modifications and portable impedance meter approached the purchase value of the Emotiv system. Preliminary analyses revealed significantly more trials were rejected from data acquired by the modified Emotiv compared to the SynAmps system. However, the ERP waveforms captured by the Emotiv system were found to be highly similar to the corresponding waveform from the SynAmps system. The latency and peak amplitude of N200 and P300 components were also found to be similar between systems. Overall, the results indicate that, in the context of an oddball task, the ERP acquired by a low-cost wireless EEG system can be of comparable quality to research-grade EEG acquisition equipment. © 2017 Society for Psychophysiological Research.

  16. Comparative analysis of the outflow water quality of two sustainable linear drainage systems.

    PubMed

    Andrés-Valeri, V C; Castro-Fresno, D; Sañudo-Fontaneda, L A; Rodriguez-Hernandez, J

    2014-01-01

    Three different drainage systems were built in a roadside car park located on the outskirts of Oviedo (Spain): two sustainable urban drainage systems (SUDS), a swale and a filter drain; and one conventional drainage system, a concrete ditch, which is representative of the most frequently used roadside drainage system in Spain. The concentrations of pollutants were analyzed in the outflow of all three systems in order to compare their capacity to improve water quality. Physicochemical water quality parameters such as dissolved oxygen, total suspended solids, pH, electrical conductivity, turbidity and total petroleum hydrocarbons were monitored and analyzed for 25 months. Results are presented in detail showing significantly smaller amounts of outflow pollutants in SUDS than in conventional drainage systems, especially in the filter drain which provided the best performance.

  17. Futurescapes: evidence expectations in the USA for comparative effectiveness research for drugs in 2020.

    PubMed

    Messner, Donna A; Mohr, Penny; Towse, Adrian

    2015-08-01

    Explore key factors influencing future expectations for the production of evidence from comparative effectiveness research for drugs in the USA in 2020 and construct three plausible future scenarios. Semistructured key informant interviews and three rounds of modified Delphi with systematic scenario-building methods. Most influential key factors were: health delivery system integration; electronic health record development; exploitation of very large databases and mixed data sources; and proactive patient engagement in research. The scenario deemed most likely entailed uneven development of large integrated health systems with pockets of increased provider risk for patient care, enhanced data collection systems, changing incentives to do comparative effectiveness research and new opportunities for evidence generation partnerships.

  18. Motor run-up system. [power lines

    NASA Technical Reports Server (NTRS)

    Daeges, J. J. (Inventor)

    1975-01-01

    A starting system is described for bringing a large synchronous motor up to speed to prevent large power line disturbances at the moment the motor is connected to the power line. The system includes (1) a digital counter which generates a count determined by the difference in frequency between the power line and a small current generated by the synchronous motor; (2) a latch which stores the count; and (3) a comparator which compares the stored count with a newly generated count to determine whether the synchronous motor is accelerating or decelerating. Signals generated by the counter and comparator control the current to a clutch that couples a starting motor to the large synchronous motor.

  19. Performance evaluation of integrating detectors for near-infrared fluorescence molecular imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Banghe; Rasmussen, John C.; Sevick-Muraca, Eva M.

    2014-05-01

    Although there has been a plethora of devices advanced for clinical translation, there has been no standards to compare and determine the optical device for fluorescence molecular imaging. In this work, we compare different CCD configurations using a solid phantom developed to mimic pM - fM concentrations of near-infrared fluorescent dyes in tissues. Our results show that intensified CCD systems (ICCDs) offer greater contrast at larger signal-tonoise ratios (SNRs) in comparison to their un-intensified CCD systems operated at clinically reasonable, sub-second acquisition times. Furthermore, we compared our investigational ICCD device to the commercial NOVADAQ SPY system, demonstrating different performance in both SNR and contrast.

  20. Evaluation of a multiarray system for pharmaceutical analysis by microemulsion electrokinetic chromatography.

    PubMed

    Lynen, Frederic; Saavedra, Luis; Saveedra, Luis; Nickerson, Beverly; Sandra, Pat

    2011-05-15

    A multiplexed capillary electrophoresis (CE) system equipped with 96 channels was evaluated for high-throughput screening in drug discovery by microemulsion electrokinetic chromatography (MEEKC). Method transfer from a single channel to a multichannel CE system is described. Loss of efficiency and reduced migration times could be elucidated to the poor efficacy in Joule heat dissipation by forced air cooling in the multiarray system compared to liquid cooling in the single channel instrument. On the other hand, only 48 channels could actually be used because of the maximum total current of 3 mA. Precision data remained below 8% and 9% for migration times and peak areas, respectively. Some UV-detector cross-talk interference between neighboring capillary channels was noted. Impurities at 0.5% compared to the main peak (100%) could be detected with the multiplexed system which is 10 times lower compared to the single capillary system. Higher efficiency and improved figures of merit (absolute sensitivity and no cross-talk interferences) were obtained by using an array of only 24 capillaries. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment.

    PubMed

    Shivanand, Sunita; Patil, Chetan R; Thangala, Venugopal; Kumar, Pabbati Ravi; Sachdeva, Jyoti; Krishna, Akash

    2013-05-01

    To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment. Sixty extracted premolars were retreated with following systems: Group -ProTaper Universal retreatment files, Group 2-ProFile system, Group 3-H-file. Specimens were split longitudinally and amount of remaining gutta-percha on the canal walls was assessed using direct visual scoring with the aid of stereomicroscope. Results were statistically analyzed using ANOVA test. Completely clean root canal walls were not achieved with any of the techniques investigated. However, all three systems proved to be effective for gutta-percha removal. Significant difference was found between ProTaper universal retreatment file and H-file, and also between ProFile and H-file. Under the conditions of the present study, ProTaper Universal retreatment files left significantly less guttapercha and sealer than ProFile and H-file. Rotary systems in combination with gutta-percha solvents can perform superiorly as compared to the time tested traditional hand instrumentation in root canal retreatment.

  2. Performance appraisal of online MEDLINE access routes.

    PubMed Central

    Walker, C. J.; McKibbon, K. A.; Haynes, R. B.; Johnston, M. E.

    1992-01-01

    OBJECTIVE: To compare the performance and cost of 11 online MEDLINE systems with MEDLINE at Elhill. DESIGN: Comparative study. SYSTEMS: Eleven online daytime systems commercially available in North America offering the MEDLINE database. MEASURES: Number of relevant citations, number of irrelevant citations, proportion of searches producing no relevant citations and cost per relevant citation were analyzed for each system. Relevance and cost for each system were compared with direct searching of MEDLINE through NLM for librarian and clinician search strategies for 18 clinical questions. The citations retrieved by both strategies were pooled and rated for relevance on a 7-point scale. RESULTS: Numbers of relevant and irrelevant citations and cost per relevant citation were higher for clinician searches than librarian searches, reflecting the higher total number of citations retrieved by the clinician approaches. A lower proportion of clinician searches produced no relevant citations than librarian searches. CONCLUSIONS: Eleven daytime MEDLINE systems performed similarly in terms of retrieval and cost within similar searching groups. Clinicians, however, tended to capture larger overall retrievals resulting in higher numbers of relevant and irrelevant citations than librarians. PMID:1482922

  3. Voter comparator switch provides fail safe data communications system - A concept

    NASA Technical Reports Server (NTRS)

    Koczela, L. J.; Wilgus, D. S.

    1971-01-01

    System indicates status of computers and controls operational modes. Two matrices are used - one relating to permissible system states, the other relating to requested system states. Concept is useful to designers of digital data transmission systems and time shared computer systems.

  4. A Goal Seeking Strategy for Constructing Systems from Alternative Components

    NASA Technical Reports Server (NTRS)

    Valentine, Mark E.

    1999-01-01

    This paper describes a methodology to efficiently construct feasible systems then modify feasible systems to meet successive goals by selecting from alternative components, a problem recognized to be n-p complete. The methodology provides a means to catalog and model alternative components. A presented system modeling Structure is robust enough to model a wide variety of systems and provides a means to compare and evaluate alternative systems. These models act as input to a methodology for selecting alternative components to construct feasible systems and modify feasible systems to meet design goals and objectives. The presented algorithm's ability to find a restricted solution, as defined by a unique set of requirements, is demonstrated against an exhaustive search of a sample of proposed shuttle modifications. The utility of the algorithm is demonstrated by comparing results from the algorithm with results from three NASA shuttle evolution studies using their value systems and assumptions.

  5. Analysis of a front suspension system for UniART FSAE car using FEA

    NASA Astrophysics Data System (ADS)

    Zaidie, M. N. A.; Hashim, M. S. M.; Tasyrif, M.; Basha, M. H.; Ibrahim, I.; Kamaruddin, N. S.; Shahriman, A. B.

    2017-10-01

    In recent years, many research works from institutions that participated in Formula SAE had highlighted on suspension systems. The aim is to improve the system in term of performance and robustness. However, every suspension system for a racing car is tailored to the car itself. Thus, this paper proposes a new design for front suspension system for UniART FSAE car. The new design was than being compared to the previous suspension system for enhancement. The analysis covered in this paper based on several conditions such as braking, cornering and bumping condition and was carried out using finite element analysis. Each main component for the suspension system such as lower arm, upper arm and knuckle has been analysed in term of strength and performance. From the results, the proposed new design of the suspension system has improved in term of strength and performance compared to the previous suspension system.

  6. Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Poerschke; Beach, R.; Beggs, T.

    2016-08-26

    IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements.« less

  7. A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beshr, M.; Aute, V.; Sharma, V.

    Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Consequently, the interest in using low GWP refrigerants such as carbon dioxide (CO 2) and new refrigerant blends is increasing. In this study, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of four supermarket refrigeration systems: a transcritical CO 2 booster system, a cascade CO 2/N-40 system, a combined secondary circuit with central DX N-40/L-40 system, and a baseline multiplex direct expansion system utilizing R-404A and N-40. The study is performed for different climatesmore » within the USA using EnergyPlus to simulate the systems' hourly performance. Finally, further analyses are presented such as parametric, sensitivity, and uncertainty analyses to study the impact of different system parameters on the LCCP.« less

  8. A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants

    DOE PAGES

    Beshr, M.; Aute, V.; Sharma, V.; ...

    2015-04-09

    Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Consequently, the interest in using low GWP refrigerants such as carbon dioxide (CO 2) and new refrigerant blends is increasing. In this study, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of four supermarket refrigeration systems: a transcritical CO 2 booster system, a cascade CO 2/N-40 system, a combined secondary circuit with central DX N-40/L-40 system, and a baseline multiplex direct expansion system utilizing R-404A and N-40. The study is performed for different climatesmore » within the USA using EnergyPlus to simulate the systems' hourly performance. Finally, further analyses are presented such as parametric, sensitivity, and uncertainty analyses to study the impact of different system parameters on the LCCP.« less

  9. Comparison of the compressive strength of 3 different implant design systems.

    PubMed

    Pedroza, Jose E; Torrealba, Ysidora; Elias, Augusto; Psoter, Walter

    2007-01-01

    The aims of this study were twofold: to compare the static compressive strength at the implant-abutment interface of 3 design systems and to describe the implant abutment connection failure mode. A stainless steel holding device was designed to align the implants at 30 degrees with respect to the y-axis. Sixty-nine specimens were used, 23 for each system. A computer-controlled universal testing machine (MTS 810) applied static compression loading by a unidirectional vertical piston until failure. Specimens were evaluated macroscopically for longitudinal displacement, abutment looseness, and screw and implant fracture. Data were analyzed by analysis of variance (ANOVA). The mean compressive strength for the Unipost system was 392.5 psi (SD +/-40.9), for the Spline system 342.8 psi (SD+/-25.8), and for the Screw-Vent system 269.1 psi (SD+/-30.7). The Unipost implant-abutment connection demonstrated a statistically significant superior mechanical stability (P < or = .009) compared with the Spline implant system. The Spline implant system showed a statistically significant higher compressive strength than the Screw-Vent implant system (P < or =.009). Regarding failure mode, the Unipost system consistently broke at the same site, while the other systems failed at different points of the connection. The Unipost system demonstrated excellent fracture resistance to compressive forces; this resistance may be attributed primarily to the diameter of the abutment screw and the 2.5 mm counter bore, representing the same and a unique piece of the implant. The Unipost implant system demonstrated a statistically significant superior compressive strength value compared with the Spline and Screw-Vent systems, at a 30 degrees angulation.

  10. Language Research Center's Computerized Test System (LRC-CTS) - Video-formatted tasks for comparative primate research

    NASA Technical Reports Server (NTRS)

    Rumbaugh, Duane M.; Washburn, David A.; Savage-Rumbaugh, E. S.; Hopkins, William D.; Richardson, W. K.

    1991-01-01

    Automation of a computerized test system for comparative primate research is shown to improve the results of learning in standard paradigms. A mediational paradigm is used to determine the degree to which criterion in the learning-set testing reflects stimulus-response associative or mediational learning. Rhesus monkeys are shown to exhibit positive transfer as the criterion levels are shifted upwards, and the effectiveness of the computerized testing system is confirmed.

  11. Four-dimensional computed tomography based respiratory-gated radiotherapy with respiratory guidance system: analysis of respiratory signals and dosimetric comparison.

    PubMed

    Lee, Jung Ae; Kim, Chul Yong; Yang, Dae Sik; Yoon, Won Sup; Park, Young Je; Lee, Suk; Kim, Young Bum

    2014-01-01

    To investigate the effectiveness of respiratory guidance system in 4-dimensional computed tomography (4 DCT) based respiratory-gated radiation therapy (RGRT) by comparing respiratory signals and dosimetric analysis of treatment plans. The respiratory amplitude and period of the free, the audio device-guided, and the complex system-guided breathing were evaluated in eleven patients with lung or liver cancers. The dosimetric parameters were assessed by comparing free breathing CT plan and 4 DCT-based 30-70% maximal intensity projection (MIP) plan. The use of complex system-guided breathing showed significantly less variation in respiratory amplitude and period compared to the free or audio-guided breathing regarding the root mean square errors (RMSE) of full inspiration (P = 0.031), full expiration (P = 0.007), and period (P = 0.007). The dosimetric parameters including V(5 Gy), V(10 Gy), V(20 Gy), V(30 Gy), V(40 Gy), and V(50 Gy) of normal liver or lung in 4 DCT MIP plan were superior over free breathing CT plan. The reproducibility and regularity of respiratory amplitude and period were significantly improved with the complex system-guided breathing compared to the free or the audio-guided breathing. In addition, the treatment plan based on the 4D CT-based MIP images acquired with the complex system guided breathing showed better normal tissue sparing than that on the free breathing CT.

  12. Cold Plasma Welding System for Surgical Skin Closure: In Vivo Porcine Feasibility Assessment.

    PubMed

    Harats, Moti; Lam, Amnon; Maller, Michael; Kornhaber, Rachel; Haik, Josef

    2016-09-29

    Cold plasma skin welding is a novel technology that bonds skin edges through soldering without the use of synthetic materials or conventional wound approximation methods such as sutures, staples, or skin adhesives. The cold plasma welding system uses a biological solder applied to the edges of a skin incision, followed by the application of cold plasma energy. The objectives of this study were to assess the feasibility of a cold plasma welding system in approximating and fixating skin incisions compared with conventional methods and to evaluate and define optimal plasma welding parameters and histopathological tissue response in a porcine model. The cold plasma welding system (BioWeld1 System, IonMed Ltd, Yokneam, Israel) was used on porcine skin incisions using variable energy parameters. Wound healing was compared macroscopically and histologically to incisions approximated with sutures. When compared to sutured skin closure, cold plasma welding in specific system parameters demonstrated comparable and favorable wound healing results histopathologically as well as macroscopically. No evidence of epidermal damage, thermal or otherwise, was encountered in the specified parameters. Notably, bleeding, infection, and wound dehiscence were not detected at incision sites. Skin incisions welded at extreme energy parameters presented second-degree burns. Implementation of cold plasma welding has been shown to be feasible for skin closure. Initial in vivo results suggest cold plasma welding might provide equal, if not better, healing results than traditional methods of closure.

  13. Performance of high intensity fed-batch mammalian cell cultures in disposable bioreactor systems.

    PubMed

    Smelko, John Paul; Wiltberger, Kelly Rae; Hickman, Eric Francis; Morris, Beverly Janey; Blackburn, Tobias James; Ryll, Thomas

    2011-01-01

    The adoption of disposable bioreactor technology as an alternate to traditional nondisposable technology is gaining momentum in the biotechnology industry. Evaluation of current disposable bioreactors systems to sustain high intensity fed-batch mammalian cell culture processes needs to be explored. In this study, an assessment was performed comparing single-use bioreactors (SUBs) systems of 50-, 250-, and 1,000-L operating scales with traditional stainless steel (SS) and glass vessels using four distinct mammalian cell culture processes. This comparison focuses on expansion and production stage performance. The SUB performance was evaluated based on three main areas: operability, process scalability, and process performance. The process performance and operability aspects were assessed over time and product quality performance was compared at the day of harvest. Expansion stage results showed disposable bioreactors mirror traditional bioreactors in terms of cellular growth and metabolism. Set-up and disposal times were dramatically reduced using the SUB systems when compared with traditional systems. Production stage runs for both Chinese hamster ovary and NS0 cell lines in the SUB system were able to model SS bioreactors runs at 100-, 200-, 2,000-, and 15,000-L scales. A single 1,000-L SUB run applying a high intensity fed-batch process was able to generate 7.5 kg of antibody with comparable product quality. Copyright © 2011 American Institute of Chemical Engineers (AIChE).

  14. Comparing performance in discrete and continuous comparison tasks.

    PubMed

    Leibovich, Tali; Henik, Avishai

    2014-05-01

    The approximate number system (ANS) theory suggests that all magnitudes, discrete (i.e., number of items) or continuous (i.e., size, density, etc.), are processed by a shared system and comply with Weber's law. The current study reexamined this notion by comparing performance in discrete (comparing numerosities of dot arrays) and continuous (comparisons of area of squares) tasks. We found that: (a) threshold of discrimination was higher for continuous than for discrete comparisons; (b) while performance in the discrete task complied with Weber's law, performance in the continuous task violated it; and (c) performance in the discrete task was influenced by continuous properties (e.g., dot density, dot cumulative area) of the dot array that were not predictive of numerosities or task relevant. Therefore, we propose that the magnitude processing system (MPS) is actually divided into separate (yet interactive) systems for discrete and continuous magnitude processing. Further subdivisions are discussed. We argue that cooperation between these systems results in a holistic comparison of magnitudes, one that takes into account continuous properties in addition to numerosities. Considering the MPS as two systems opens the door to new and important questions that shed light on both normal and impaired development of the numerical system.

  15. Mirror fusion propulsion system: A performance comparison with alternate propulsion systems for the manned Mars Mission

    NASA Technical Reports Server (NTRS)

    Schulze, Norman R.; Carpenter, Scott A.; Deveny, Marc E.; Oconnell, T.

    1993-01-01

    The performance characteristics of several propulsion technologies applied to piloted Mars missions are compared. The characteristics that are compared are Initial Mass in Low Earth Orbit (IMLEO), mission flexibility, and flight times. The propulsion systems being compared are both demonstrated and envisioned: Chemical (or Cryogenic), Nuclear Thermal Rocket (NTR) solid core, NTR gas core, Nuclear Electric Propulsion (NEP), and a mirror fusion space propulsion system. The proposed magnetic mirror fusion reactor, known as the Mirror Fusion Propulsion System (MFPS), is described. The description is an overview of a design study that was conducted to convert a mirror reactor experiment at Lawrence Livermore National Lab (LLNL) into a viable space propulsion system. Design principles geared towards minimizing mass and maximizing power available for thrust are identified and applied to the LLNL reactor design, resulting in the MFPS. The MFPS' design evolution, reactor and fuel choices, and system configuration are described. Results of the performance comparison shows that the MFPS minimizes flight time to 60 to 90 days for flights to Mars while allowing continuous return-home capability while at Mars. Total MFPS IMLEO including propellant and payloads is kept to about 1,000 metric tons.

  16. Design and evaluation of a miniature laser speckle imaging device to assess gingival health

    PubMed Central

    Regan, Caitlin; White, Sean M.; Yang, Bruce Y.; Takesh, Thair; Ho, Jessica; Wink, Cherie; Wilder-Smith, Petra; Choi, Bernard

    2016-01-01

    Abstract. Current methods used to assess gingivitis are qualitative and subjective. We hypothesized that gingival perfusion measurements could provide a quantitative metric of disease severity. We constructed a compact laser speckle imaging (LSI) system that could be mounted in custom-made oral molds. Rigid fixation of the LSI system in the oral cavity enabled measurement of blood flow in the gingiva. In vitro validation performed in controlled flow phantoms demonstrated that the compact LSI system had comparable accuracy and linearity compared to a conventional bench-top LSI setup. In vivo validation demonstrated that the compact LSI system was capable of measuring expected blood flow dynamics during a standard postocclusive reactive hyperemia and that the compact LSI system could be used to measure gingival blood flow repeatedly without significant variation in measured blood flow values (p<0.05). Finally, compact LSI system measurements were collected from the interdental papilla of nine subjects and compared to a clinical assessment of gingival bleeding on probing. A statistically significant correlation (ρ=0.53; p<0.005) was found between these variables, indicating that quantitative gingival perfusion measurements performed using our system may aid in the diagnosis and prognosis of periodontal disease. PMID:27787545

  17. Description and Evaluation of the 2009–2010 Pennsylvania Influenza Sentinel School Monitoring System

    PubMed Central

    Marriott, Chandra K.; Ostroff, Stephen; Waller, Kirsten

    2011-01-01

    Objectives. We described and evaluated the 2009–2010 Pennsylvania Influenza Sentinel School Monitoring System, a voluntary sentinel network of schools that report data on school absenteeism and visits to the school nurse for influenza-like illness (ILI). Methods. Participating schools provided daily absenteeism and ILI data on a weekly basis through an online survey. We used participation and weekly response rates to determine acceptability, timeliness, and simplicity. We assessed representativeness by comparing participating schools with nonparticipating schools. We compared monitoring system data with statewide reports of laboratory-confirmed influenza. Results. Of the 3244 Pennsylvania public schools, 367 (11%) enrolled in the system. On average, 79% of enrolled schools completed the survey each week. Although the peak week of elevated absenteeism coincided with the peak of statewide laboratory-confirmed influenza cases, the correlation between absenteeism and state data was nonsignificant (correlation coefficient = 0.10; P = .56). Trends in ILI correlated significantly with state data (correlation coefficient = 0.67; P < .001). Conclusions. The school-based sentinel system is a simple, acceptable, reliable device for tracking absenteeism and ILI in schools. Further analyses are necessary to determine the comparative value of this system and other influenza surveillance systems. PMID:21566024

  18. Design and evaluation of a miniature laser speckle imaging device to assess gingival health

    NASA Astrophysics Data System (ADS)

    Regan, Caitlin; White, Sean M.; Yang, Bruce Y.; Takesh, Thair; Ho, Jessica; Wink, Cherie; Wilder-Smith, Petra; Choi, Bernard

    2016-10-01

    Current methods used to assess gingivitis are qualitative and subjective. We hypothesized that gingival perfusion measurements could provide a quantitative metric of disease severity. We constructed a compact laser speckle imaging (LSI) system that could be mounted in custom-made oral molds. Rigid fixation of the LSI system in the oral cavity enabled measurement of blood flow in the gingiva. In vitro validation performed in controlled flow phantoms demonstrated that the compact LSI system had comparable accuracy and linearity compared to a conventional bench-top LSI setup. In vivo validation demonstrated that the compact LSI system was capable of measuring expected blood flow dynamics during a standard postocclusive reactive hyperemia and that the compact LSI system could be used to measure gingival blood flow repeatedly without significant variation in measured blood flow values (p<0.05). Finally, compact LSI system measurements were collected from the interdental papilla of nine subjects and compared to a clinical assessment of gingival bleeding on probing. A statistically significant correlation (ρ=0.53 p<0.005) was found between these variables, indicating that quantitative gingival perfusion measurements performed using our system may aid in the diagnosis and prognosis of periodontal disease.

  19. Mirror fusion propulsion system - A performance comparison with alternate propulsion systems for the manned Mars mission

    NASA Technical Reports Server (NTRS)

    Deveny, M.; Carpenter, S.; O'Connell, T.; Schulze, N.

    1993-01-01

    The performance characteristics of several propulsion technologies applied to piloted Mars missions are compared. The characteristics that are compared are Initial Mass in Low Earth Orbit (IMLEO), mission flexibility, and flight times. The propulsion systems being compared are both demonstrated and envisioned: Chemical (or Cryogenic), Nuclear Thermal Rocket (NTR) solid core, NTR gas core, Nuclear Electric Propulsion (NEP), and a mirror fusion space propulsion system. The proposed magnetic mirror fusion reactor, known as the Mirror Fusion Propulsion System (MFPS), is described. The description is an overview of a design study that was conducted to convert a mirror reactor experiment at Lawrence Livermore National Lab (LLNL) into a viable space propulsion system. Design principles geared towards minimizing mass and maximizing power available for thrust are identified and applied to the LLNL reactor design, resulting in the MFPS. The MFPS' design evolution, reactor and fuel choices, and system configuration are described. Results of the performance comparison shows that the MFPS minimizes flight time to 60 to 90 days for flights to Mars while allowing continuous return-home capability while at Mars. Total MFPS IMLEO including propellant and payloads is kept to about 1,000 metric tons.

  20. Heat dissipation for microprocessor using multiwalled carbon nanotubes based liquid.

    PubMed

    Hung Thang, Bui; Trinh, Pham Van; Chuc, Nguyen Van; Khoi, Phan Hong; Minh, Phan Ngoc

    2013-01-01

    Carbon nanotubes (CNTs) are one of the most valuable materials with high thermal conductivity (2000 W/m · K compared with thermal conductivity of Ag 419 W/m · K). This suggested an approach in applying the CNTs in thermal dissipation system for high power electronic devices, such as computer processor and high brightness light emitting diode (HB-LED). In this work, multiwalled carbon nanotubes (MWCNTs) based liquid was made by COOH functionalized MWCNTs dispersed in distilled water with concentration in the range between 0.2 and 1.2 gram/liter. MWCNT based liquid was used in liquid cooling system to enhance thermal dissipation for computer processor. By using distilled water in liquid cooling system, CPU's temperature decreases by about 10°C compared with using fan cooling system. By using MWCNT liquid with concentration of 1 gram/liter MWCNTs, the CPU's temperature decreases by 7°C compared with using distilled water in cooling system. Theoretically, we also showed that the presence of MWCNTs reduced thermal resistance and increased the thermal conductivity of liquid cooling system. The results have confirmed the advantages of the MWCNTs for thermal dissipation systems for the μ -processor and other high power electronic devices.

  1. Co-delivery of vascular endothelial growth factor and angiopoietin-1 using injectable microsphere/hydrogel hybrid systems for therapeutic angiogenesis.

    PubMed

    Shin, Seung-Hwa; Lee, Jangwook; Ahn, Dong-Gyun; Lee, Kuen Yong

    2013-08-01

    We hypothesized that combined delivery of vascular endothelial growth factor (VEGF) and angiopoietin-1 (Ang-1) using microsphere/hydrogel hybrid systems could enhance mature vessel formation compared with administration of each factor alone. Hybrid delivery systems composed of alginate hydrogels and poly(D,L-lactic-co-glycolic acid) (PLGA) microspheres containing angiogenic factors were prepared. The release behavior of angiogenic factors from hybrid systems was monitored in vitro. The hybrid systems were injected into an ischemic rodent model, and blood vessel formation at the ischemic site was evaluated. The sustained release over 4 weeks of both VEGF and Ang-1 from hybrid systems was achieved in vitro. Co-delivery of VEGF and Ang-1 was advantageous to retain muscle tissues and significantly induced vessel enlargement at the ischemic site, compared to mice treated with either VEGF or Ang-1 alone. Sustained and combined delivery of VEGF and Ang-1 significantly enhances vessel enlargement at the ischemic site, compared with sustained delivery of either factor alone. Microsphere/hydrogel hybrid systems may be a promising vehicle for delivery of multiple drugs for many therapeutic applications.

  2. Assessment of apically extruded debris produced by the self-adjusting file system.

    PubMed

    De-Deus, Gustavo André; Nogueira Leal Silva, Emmanuel João; Moreira, Edson Jorge; de Almeida Neves, Aline; Belladonna, Felipe Gonçalves; Tameirão, Michele

    2014-04-01

    This study was designed to quantitatively evaluate the amount of apically extruded debris by the Self-Adjusting-File system (SAF; ReDent-Nova, Ra'anana, Israel). Hand and rotary instruments were used as references for comparison. Sixty mesial roots of mandibular molars were randomly assigned to 3 groups (n = 20). The root canals were instrumented with hand files using a crown-down technique. The ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) and SAF systems were used according to the manufacturers' instructions. Sodium hypochlorite was used as an irrigant, and the apically extruded debris was collected in preweighted glass vials and dried afterward. The mean weight of debris was assessed with a microbalance and statistically analyzed using 1-way analysis of variance and the post hoc Tukey multiple comparison test. Hand file instrumentation produced significantly more debris compared with the ProTaper and SAF systems (P < .05). The ProTaper system produced significantly more debris compared with the SAF system (P < .05). Under the conditions of this study, all systems caused apical debris extrusion. SAF instrumentation was associated with less debris extrusion compared with the use of hand and rotary files. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Reduction of oxygen concentration by heater design during Czochralski Si growth

    NASA Astrophysics Data System (ADS)

    Zhou, Bing; Chen, Wenliang; Li, Zhihui; Yue, Ruicun; Liu, Guowei; Huang, Xinming

    2018-02-01

    Oxygen is one of the highest-concentration impurities in single crystals grown by the Czochralski (CZ) process, and seriously impairs the quality of the Si wafer. In this study, computer simulations were applied to design a new CZ system. A more appropriate thermal field was acquired by optimization of the heater structure. The simulation results showed that, compared with the conventional system, the oxygen concentration in the newly designed CZ system was reduced significantly throughout the entire CZ process because of the lower crucible wall temperature and optimized convection. To verify the simulation results, experiments were conducted on an industrial single-crystal furnace. The experimental results showed that the oxygen concentration was reduced significantly, especially at the top of the CZ-Si ingot. Specifically, the oxygen concentration was 6.19 × 1017 atom/cm3 at the top of the CZ-Si ingot with the newly designed CZ system, compared with 9.22 × 1017 atom/cm3 with the conventional system. Corresponding light-induced degradation of solar cells based on the top of crystals from the newly designed CZ system was 1.62%, a reduction of 0.64% compared with crystals from the conventional system (2.26%).

  4. Comparative evaluation of distributed-collector solar thermal electric power plants

    NASA Technical Reports Server (NTRS)

    Fujita, T.; El Gabalawi, N.; Herrera, G. G.; Caputo, R. S.

    1978-01-01

    Distributed-collector solar thermal-electric power plants are compared by projecting power plant economics of selected systems to the 1990-2000 timeframe. The approach taken is to evaluate the performance of the selected systems under the same weather conditions. Capital and operational costs are estimated for each system. Energy costs are calculated for different plant sizes based on the plant performance and the corresponding capital and maintenance costs. Optimum systems are then determined as the systems with the minimum energy costs for a given load factor. The optimum system is comprised of the best combination of subsystems which give the minimum energy cost for every plant size. Sensitivity analysis is done around the optimum point for various plant parameters.

  5. The effect of the liquid-solid system properties on the interline heat transfer coefficient

    NASA Technical Reports Server (NTRS)

    Wayner, P. C., Jr.

    1977-01-01

    A theoretical procedure to determine the heat transfer characteristics of the interline region of an evaporating meniscus using the macroscopic optical and thermophysical properties of the system is outlined. The analysis is based on the premise that the interline transport processes are controlled by the London-van der Waals forces between condensed phases (solid and liquid). The procedure is used to compare the relative size of the interline heat sink of various systems using a constant heat flux model. This solution demonstrates the importance of the interline heat flow number which is evaluated for various systems. The heat transfer characteristics of the decane-steel system are numerically compared with those of the carbon tetrachloride-quartz system.

  6. Interactive Technologies for Teacher Training: Comparing Performance and Assessment in Second Life and simSchool

    ERIC Educational Resources Information Center

    Meritt, Julia; Gibson, David; Christensen, Rhonda; Knezek, Gerald

    2013-01-01

    Two alternative technologies forming the basis of computer-mediated teacher preparation systems are compared and contrasted regarding implementation, operation, and assessment considerations. The role-playing system in Second Life is shown to have the unique characteristic of developing a co-constructed pedagogical identity, while the flight…

  7. Validation of the Unthinned Loblolly Pine Plantation Yield Model-USLYCOWG

    Treesearch

    V. Clark Baldwin; D.P. Feduccia

    1982-01-01

    Yield and stand structure predictions from an unthinned loblolly pine plantation yield prediction system (USLYCOWG computer program) were compared with observations from 80 unthinned loblolly pine plots. Overall, the predicted estimates were reasonable when compared to observed values, but predictions based on input data at or near the system's limits may be in...

  8. A Student-Centered Field Project Comparing NEXRAD and Rain Gauge Precipitation Values in Mountainous Terrain.

    ERIC Educational Resources Information Center

    Woltemade, Christopher J.; Stanitski-Martin, Diane

    2002-01-01

    Undergraduate students compared Next Generation Weather Radar (NEXRAD) estimates of storm total precipitation to measurements from a network of 20 rain gauges. Student researchers gained valuable experience in field data collection, global positioning systems (GPS), geographic information systems (GIS), Internet data access and downloading,…

  9. Islam through the History and Culture of Pakistan. Fulbright-Hays Summer Seminar Abroad Project, 1994.

    ERIC Educational Resources Information Center

    Wilson, William E.

    This project introduces a syllabus for studying comparative politics among Canada, Pakistan, and Japan. Students learn that comparative politics provides an understanding of how different political systems operate and the importance of culture in understanding politics. Three functions are addressed in the course: system functions, process…

  10. Multi-channel temperature measurement amplification system. [solar heating systems

    NASA Technical Reports Server (NTRS)

    Currie, J. R. (Inventor)

    1981-01-01

    A number of differential outputs of thermocouples are sequentially amplified by a common amplifier. The amplified outputs are compared with a reference temperature signal in an offset correction amplifier, and a particularly poled output signal is provided when a differential output is of a discrete level compared with a reference temperature signal.

  11. An Investigation of Energy Consumption and Cost in Large Air-Conditioned Buildings. An Interim Report.

    ERIC Educational Resources Information Center

    Milbank, N. O.

    Two similarly large buildings and air conditioning systems are comparatively analyzed as to energy consumption, costs, and inefficiency during certain measured periods of time. Building design and velocity systems are compared to heating, cooling, lighting and distribution capabilities. Energy requirements for pumps, fans and lighting are found to…

  12. Comparing Online to Face-To-Face Delivery of Undergraduate Digital Circuits Content

    ERIC Educational Resources Information Center

    LaMeres, Brock J.; Plumb, Carolyn

    2014-01-01

    This paper presents a comparison of online to traditional face-to-face delivery of undergraduate digital systems material. Two specific components of digital content were compared and evaluated: a sophomore logic circuits course with no laboratory, and a microprocessor laboratory component of a junior-level computer systems course. For each of…

  13. Feeding Behavior of Aplysia: A Model System for Comparing Cellular Mechanisms of Classical and Operant Conditioning

    ERIC Educational Resources Information Center

    Baxter, Douglas A.; Byrne, John H.

    2006-01-01

    Feeding behavior of Aplysia provides an excellent model system for analyzing and comparing mechanisms underlying appetitive classical conditioning and reward operant conditioning. Behavioral protocols have been developed for both forms of associative learning, both of which increase the occurrence of biting following training. Because the neural…

  14. Comparison of hydraulics and particle removal efficiencies in a mixed cell raceway and burrows pond rearing system

    USDA-ARS?s Scientific Manuscript database

    We compared the hydrodynamics of replicate experimental mixed cell and replicate standard Burrows pond rearing systems at the Dworshak National Fish Hatchery, ID, in an effort to identify methods for improved solids removal. We measured and compared the hydraulic residence time, particle removal eff...

  15. Structures of School Systems Worldwide: A Comparative Study

    ERIC Educational Resources Information Center

    Popov, Nikolay

    2012-01-01

    In the past 20 years I have been examining the structures of school systems worldwide. This ongoing research has been enriched by the findings obtained from the lecture course on Comparative Education I have been delivering to students in the Bachelor and Master's Education Programs at Sofia University, Bulgaria. This paper presents some results…

  16. Wallerstein's World-Systems Analysis in Comparative Education: A Case Study

    ERIC Educational Resources Information Center

    Griffiths, Tom G.; Knezevic, Lisa

    2010-01-01

    Since the 1970s, using his world-systems analysis, Immanuel Wallerstein has developed a wide-ranging framework for the social sciences, with potential applications for comparative educational research. In this paper we outline key aspects of Wallerstein's theorising, and then analyse the uptake, understandings, and applications of his analysis in…

  17. Instructional Videos for Supporting Older Adults Who Use Interactive Systems

    ERIC Educational Resources Information Center

    Gramss, Denise; Struve, Doreen

    2009-01-01

    The study reported in this paper investigated the usefulness of different instructions for guiding inexperienced older adults through interactive systems. It was designed to compare different media in relation to their social as well as their motivational impact on the elderly during the learning process. Precisely, the video was compared with…

  18. Nation as Context: Comparing Child-Care Systems across Nations.

    ERIC Educational Resources Information Center

    Lubeck, Sally

    1995-01-01

    Reviews recent trends in female employment and preschool provision in the United States and Europe, discussing how governments have responded to the issues. "Nation as context," a type of cross-national research, is developed by comparing and contrasting child care and early education systems in Germany, France, and the United States.…

  19. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device.

    PubMed

    Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W

    2013-01-01

    The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.

  20. Performance optimization of CO 2 heat pump water heater

    DOE PAGES

    Nawaz, Kashif; Shen, Bo; Elatar, Ahmed; ...

    2017-10-14

    A preliminary analysis was conducted to analyze the performance of a heat pump water heater (HPWH) that uses CO 2 as the refrigerant. A model to predict the performance was developed and calibrated based on the experimental data for an existing HPWH using a CO 2 refrigerant. The calibrated model was then used to run a parametric analysis in which factors such as water supply temperature, water circulation rate, tank stratification, and condenser configuration were considered. The performance of a commercial CO 2 system was compared with that of a similar system using R-134a as the refrigerant. It was foundmore » that CO 2 HPWH performance was comparable to that of an R-134a HPWH, more so for a separated gas cooler configuration. For comparable performance, the compressor size and the tube-in-tube heat exchanger (condenser/gas cooler) size were compared for CO 2- and R-134a-based systems. Finally, the impact of the water circulation rate on the water temperature stratification in the tank, an essential requirement for higher performance for CO 2 HPWH systems was also investigated.« less

  1. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device

    PubMed Central

    Gohean, Jeffrey R.; George, Mitchell J.; Pate, Thomas D.; Kurusz, Mark; Longoria, Raul G.; Smalling, Richard W.

    2012-01-01

    The purpose of this investigation is to utilize a computational model to compare a synchronized valveless pulsatile left ventricular assist device to continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous, pulsatile, valveless, dual piston positive displacement pump. These results were compared to measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared to the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device. PMID:23438771

  2. Performance optimization of CO 2 heat pump water heater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nawaz, Kashif; Shen, Bo; Elatar, Ahmed

    A preliminary analysis was conducted to analyze the performance of a heat pump water heater (HPWH) that uses CO 2 as the refrigerant. A model to predict the performance was developed and calibrated based on the experimental data for an existing HPWH using a CO 2 refrigerant. The calibrated model was then used to run a parametric analysis in which factors such as water supply temperature, water circulation rate, tank stratification, and condenser configuration were considered. The performance of a commercial CO 2 system was compared with that of a similar system using R-134a as the refrigerant. It was foundmore » that CO 2 HPWH performance was comparable to that of an R-134a HPWH, more so for a separated gas cooler configuration. For comparable performance, the compressor size and the tube-in-tube heat exchanger (condenser/gas cooler) size were compared for CO 2- and R-134a-based systems. Finally, the impact of the water circulation rate on the water temperature stratification in the tank, an essential requirement for higher performance for CO 2 HPWH systems was also investigated.« less

  3. Comparative Microbial Modules Resource: Generation and Visualization of Multi-species Biclusters

    PubMed Central

    Bate, Ashley; Eichenberger, Patrick; Bonneau, Richard

    2011-01-01

    The increasing abundance of large-scale, high-throughput datasets for many closely related organisms provides opportunities for comparative analysis via the simultaneous biclustering of datasets from multiple species. These analyses require a reformulation of how to organize multi-species datasets and visualize comparative genomics data analyses results. Recently, we developed a method, multi-species cMonkey, which integrates heterogeneous high-throughput datatypes from multiple species to identify conserved regulatory modules. Here we present an integrated data visualization system, built upon the Gaggle, enabling exploration of our method's results (available at http://meatwad.bio.nyu.edu/cmmr.html). The system can also be used to explore other comparative genomics datasets and outputs from other data analysis procedures – results from other multiple-species clustering programs or from independent clustering of different single-species datasets. We provide an example use of our system for two bacteria, Escherichia coli and Salmonella Typhimurium. We illustrate the use of our system by exploring conserved biclusters involved in nitrogen metabolism, uncovering a putative function for yjjI, a currently uncharacterized gene that we predict to be involved in nitrogen assimilation. PMID:22144874

  4. Comparative microbial modules resource: generation and visualization of multi-species biclusters.

    PubMed

    Kacmarczyk, Thadeous; Waltman, Peter; Bate, Ashley; Eichenberger, Patrick; Bonneau, Richard

    2011-12-01

    The increasing abundance of large-scale, high-throughput datasets for many closely related organisms provides opportunities for comparative analysis via the simultaneous biclustering of datasets from multiple species. These analyses require a reformulation of how to organize multi-species datasets and visualize comparative genomics data analyses results. Recently, we developed a method, multi-species cMonkey, which integrates heterogeneous high-throughput datatypes from multiple species to identify conserved regulatory modules. Here we present an integrated data visualization system, built upon the Gaggle, enabling exploration of our method's results (available at http://meatwad.bio.nyu.edu/cmmr.html). The system can also be used to explore other comparative genomics datasets and outputs from other data analysis procedures - results from other multiple-species clustering programs or from independent clustering of different single-species datasets. We provide an example use of our system for two bacteria, Escherichia coli and Salmonella Typhimurium. We illustrate the use of our system by exploring conserved biclusters involved in nitrogen metabolism, uncovering a putative function for yjjI, a currently uncharacterized gene that we predict to be involved in nitrogen assimilation. © 2011 Kacmarczyk et al.

  5. Economic Analysis of Kiva VCF Treatment System Compared to Balloon Kyphoplasty Using Randomized Kiva Safety and Effectiveness Trial (KAST) Data.

    PubMed

    Beall, Douglas P; Olan, Wayne J; Kakad, Priyanka; Li, Qianyi; Hornberger, John

    2015-01-01

    Vertebral compression fractures (VCFs) are the most common osteoporotic fractures and cause persistent pain, kyphotic deformity, weight loss, depression, reduced quality of life, and even death. Current surgical approaches for the treatment of VCF include vertebroplasty (VP) and balloon kyphoplasty (BK). The Kiva® VCF Treatment System (Kiva System) is a next-generation alternative surgical intervention in which a percutaneously introduced nitinol Osteo Coil guidewire is advanced through a deployment cannula and subsequently a PEEK Implant is implanted incrementally and fully coiled in the vertebral body. The Kiva System's effectiveness for the treatment of VCF has been evaluated in a large randomized controlled trial, the Kiva Safety and Effectiveness Trial (KAST). The Kiva System was non-inferior to BK with respect to pain reduction (70.8% vs. 71.8% in Visual Analogue Scale) and physical function restoration (38.1 % vs. 42.2% reduction in Oswestry Disability Index) while using less bone cement. The economic impact of the Kiva system has yet to be analyzed. To analyze hospital resource use and costs of the Kiva System over 2 years for the treatment of VCF compared to BK. A representative US hospital. Economic analysis of the KAST randomized trial, focusing on hospital resource use and costs. The analysis was conducted from a hospital perspective and utilized clinical data from KAST as well as unit-cost data from the published literature. The cost of initial VCF surgery, reoperation cost, device market cost, and other medical costs were compared between the Kiva System and BK. The relative risk reduction rate in adjacent-level fracture with Kiva [31.6% (95% CI: -22.5%, 61.9%)] demonstrated in KAST was used in this analysis. With 304 vertebral augmentation procedures performed in a representative U.S. hospital over 2 years, the Kiva System will produce a direct medical cost savings of $1,118 per patient and $280,876 per hospital. This cost saving with the Kiva System was attributable to 19 reduced adjacent-level fractures with the Kiva System. This study does not compare the Kiva System with VP or any other non-surgical procedures for the treatment of VCF. This first-ever economic analysis of the KAST data showed that the Kiva System for vertebral augmentation is hospital resource and cost saving over BK in a hospital setting over 2 years. These savings are attributable to reduced risk of developing adjacent-level fractures with the Kiva System compared to BK.

  6. Comparing a paper based monitoring and evaluation system to a mHealth system to support the national community health worker programme, South Africa: an evaluation

    PubMed Central

    2014-01-01

    Background In an attempt to address a complex disease burden, including improving progress towards MDGs 4 and 5, South Africa recently introduced a re-engineered Primary Health Care (PHC) strategy, which has led to the development of a national community health worker (CHW) programme. The present study explored the development of a cell phone-based and paper-based monitoring and evaluation (M&E) system to support the work of the CHWs. Methods One sub-district in the North West province was identified for the evaluation. One outreach team comprising ten CHWs maintained both the paper forms and mHealth system to record household data on community-based services. A comparative analysis was done to calculate the correspondence between the paper and phone records. A focus group discussion was conducted with the CHWs. Clinical referrals, data accuracy and supervised visits were compared and analysed for the paper and phone systems. Results Compared to the mHealth system where data accuracy was assured, 40% of the CHWs showed a consistently high level (>90% correspondence) of data transfer accuracy on paper. Overall, there was an improvement over time, and by the fifth month, all CHWs achieved a correspondence of 90% or above between phone and paper data. The most common error that occurred was summing the total number of visits and/or activities across the five household activity indicators. Few supervised home visits were recorded in either system and there was no evidence of the team leader following up on the automatic notifications received on their cell phones. Conclusions The evaluation emphasizes the need for regular supervision for both systems and rigorous and ongoing assessments of data quality for the paper system. Formalization of a mHealth M&E system for PHC outreach teams delivering community based services could offer greater accuracy of M&E and enhance supervision systems for CHWs. PMID:25106499

  7. SU-D-17A-07: Development and Evaluation of a Prototype Ultrasonography Respiratory Monitoring System for 4DCT Reconstruction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, P; Cheng, S; Chao, C

    Purpose: Respiratory motion artifacts are commonly seen in the abdominal and thoracic CT images. A Real-time Position Management (RPM) system is integrated with CT simulator using abdominal surface as a surrogate for tracking the patient respiratory motion. The respiratory-correlated four-dimensional computed tomography (4DCT) is then reconstructed by GE advantage software. However, there are still artifacts due to inaccurate respiratory motion detecting and sorting methods. We developed an Ultrasonography Respiration Monitoring (URM) system which can directly monitor diaphragm motion to detect respiratory cycles. We also developed a new 4DCT sorting and motion estimation method to reduce the respiratory motion artifacts. Themore » new 4DCT system was compared with RPM and the GE 4DCT system. Methods: Imaging from a GE CT scanner was simultaneously correlated with both the RPM and URM to detect respiratory motion. A radiation detector, Blackcat GM-10, recorded the X-ray on/off and synchronized with URM. The diaphragm images were acquired with Ultrasonix RP system. The respiratory wave was derived from diaphragm images and synchronized with CT scanner. A more precise peaks and valleys detection tool was developed and compared with RPM. The motion is estimated for the slices which are not in the predefined respiratory phases by using block matching and optical flow method. The CT slices were then sorted into different phases and reconstructed, compared with the images reconstructed from GE Advantage software using respiratory wave produced from RPM system. Results: The 4DCT images were reconstructed for eight patients. The discontinuity at the diaphragm level due to an inaccurate identification of phases by the RPM was significantly improved by URM system. Conclusion: Our URM 4DCT system was evaluated and compared with RPM and GE 4DCT system. The new system is user friendly and able to reduce motion artifacts. It also has the potential to monitor organ motion during therapy.« less

  8. Design-Tradeoff Model For Space Station

    NASA Technical Reports Server (NTRS)

    Chamberlain, Robert G.; Smith, Jeffrey L.; Borden, Chester S.; Deshpande, Govind K.; Fox, George; Duquette, William H.; Dilullo, Larry A.; Seeley, Larry; Shishko, Robert

    1990-01-01

    System Design Tradeoff Model (SDTM) computer program produces information which helps to enforce consistency of design objectives throughout system. Mathematical model of set of possible designs for Space Station Freedom. Program finds particular design enabling station to provide specified amounts of resources to users at lowest total (or life-cycle) cost. Compares alternative design concepts by changing set of possible designs, while holding specified services to users constant, and then comparing costs. Finally, both costs and services varied simultaneously when comparing different designs. Written in Turbo C 2.0.

  9. Grayscale image segmentation for real-time traffic sign recognition: the hardware point of view

    NASA Astrophysics Data System (ADS)

    Cao, Tam P.; Deng, Guang; Elton, Darrell

    2009-02-01

    In this paper, we study several grayscale-based image segmentation methods for real-time road sign recognition applications on an FPGA hardware platform. The performance of different image segmentation algorithms in different lighting conditions are initially compared using PC simulation. Based on these results and analysis, suitable algorithms are implemented and tested on a real-time FPGA speed sign detection system. Experimental results show that the system using segmented images uses significantly less hardware resources on an FPGA while maintaining comparable system's performance. The system is capable of processing 60 live video frames per second.

  10. Comparison of dynamic isotope power systems for distributed planet surface applications

    NASA Technical Reports Server (NTRS)

    Bents, David J.; Mckissock, Barbara I.; Hanlon, James C.; Schmitz, Paul C.; Rodriguez, Carlos D.; Withrow, Colleen A.

    1991-01-01

    Dynamic isotope power system (DIPS) alternatives were investigated and characterized for the surface mission elements associated with a lunar base and subsequent manned Mars expedition. System designs based on two convertor types were studied. These systems were characterized parametrically and compared over the steady-state electrical output power range 0.2 to 20 kWe. Three methods of thermally integrating the heat source and the Stirling heater head were considered, depending on unit size. Figures of merit were derived from the characterizations and compared over the parametric range. Design impacts of mission environmental factors are discussed and quantitatively assessed.

  11. Surface Hydrology in Global River Basins in the Off-Line Land-Surface GEOS Assimilation (OLGA) System

    NASA Technical Reports Server (NTRS)

    Bosilovich, Michael G.; Yang, Runhua; Houser, Paul R.

    1998-01-01

    Land surface hydrology for the Off-line Land-surface GEOS Analysis (OLGA) system and Goddard Earth Observing System (GEOS-1) Data Assimilation System (DAS) has been examined using a river routing model. The GEOS-1 DAS land-surface parameterization is very simple, using an energy balance prediction of surface temperature and prescribed soil water. OLGA uses near-surface atmospheric data from the GEOS-1 DAS to drive a more comprehensive parameterization of the land-surface physics. The two global systems are evaluated using a global river routing model. The river routing model uses climatologic surface runoff from each system to simulate the river discharge from global river basins, which can be compared to climatologic river discharge. Due to the soil hydrology, the OLGA system shows a general improvement in the simulation of river discharge compared to the GEOS-1 DAS. Snowmelt processes included in OLGA also have a positive effect on the annual cycle of river discharge and source runoff. Preliminary tests of a coupled land-atmosphere model indicate improvements to the hydrologic cycle compared to the uncoupled system. The river routing model has provided a useful tool in the evaluation of the GCM hydrologic cycle, and has helped quantify the influence of the more advanced land surface model.

  12. Incidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and SafeSider Systems

    PubMed Central

    Harandi, Azadeh; Mirzaeerad, Sina; Mehrabani, Mahgol; Mahmoudi, Elham; Bijani, Ali

    2017-01-01

    Introduction: This study aimed to compare the incidence of dentinal crack formation by instrumentation with ProTaper Universal system (rotary, multi-file system), SafeSider (reciprocation movement, multi-file system) and Neolix (rotary, single-file system). Methods and Materials: In this in vitro study, 60 freshly extracted mandibular first molars were randomly divided into three experimental groups (n=15) and a control group containing unprepared teeth (n=15). Instrumentation in different groups was accomplished using either ProTaper, Neolix or SafeSider systems up to 25/0.08. The teeth were then sectioned at 3, 6 and 9 mm from the apex, and observed under a stereomicroscope for presence of dentinal cracks. Data were analyzed with Chi square test, Fisher’s exact test and Bonferroni correction. Results: Micro cracks were seen in all experimental groups (13.3% in ProTaper, 26.7% in SafeSider and 40% in Neolix). There was a significant difference between Neolix and the control groups in microcrack formation (P=0.042). Micro cracks mainly occurred in the coronal section (9 mm). No microcrack occurred in the control group. Conclusion: Neolix rotary single-file system caused more dentinal cracks compared to the unprepared roots. All the instrumentation systems increased the number of micro cracks compared to unprepared teeth. PMID:29225637

  13. Low-cost three-dimensional millimeter-wave holographic imaging system based on a frequency-scanning antenna.

    PubMed

    Amin Nili, Vahid; Mansouri, Ehsan; Kavehvash, Zahra; Fakharzadeh, Mohammad; Shabany, Mahdi; Khavasi, Amin

    2018-01-01

    In this paper, a closed-form two-dimensional reconstruction technique for hybrid frequency and mechanical scanning millimeter-wave (MMW) imaging systems is proposed. Although being commercially implemented in many imaging systems as a low-cost real-time solution, the results of frequency scanning systems have been reconstructed numerically or have been reported as the captured raw data with no clear details. Furthermore, this paper proposes a new framework to utilize the captured data of different frequencies for three-dimensional (3D) reconstruction based on novel proposed closed-form relations. The hybrid frequency and mechanical scanning structure, together with the proposed reconstruction method, yields a low-cost MMW imaging system with a satisfying performance. The extracted reconstruction formulations are validated through numerical simulations, which show comparable image quality with conventional MMW imaging systems, i.e., switched-array (SA) and phased-array (PA) structures. Extensive simulations are also performed in the presence of additive noise, demonstrating the acceptable robustness of the system against system noise compared to SA and comparable performance with PA. Finally, 3D reconstruction of the simulated data shows a depth resolution of better than 10 cm with minimum degradation of lateral resolution in the 10 GHz frequency bandwidth.

  14. Mapping healthcare systems: a policy relevant analytic tool.

    PubMed

    Sekhri Feachem, Neelam; Afshar, Ariana; Pruett, Cristina; Avanceña, Anton L V

    2017-07-01

    In the past decade, an international consensus on the value of well-functioning systems has driven considerable health systems research. This research falls into two broad categories. The first provides conceptual frameworks that take complex healthcare systems and create simplified constructs of interactions and functions. The second focuses on granular inputs and outputs. This paper presents a novel translational mapping tool - the University of California, San Francisco mapping tool (the Tool) - which bridges the gap between these two areas of research, creating a platform for multi-country comparative analysis. Using the Murray-Frenk framework, we create a macro-level representation of a country's structure, focusing on how it finances and delivers healthcare. The map visually depicts the fundamental policy questions in healthcare system design: funding sources and amount spent through each source, purchasers, populations covered, provider categories; and the relationship between these entities. We use the Tool to provide a macro-level comparative analysis of the structure of India's and Thailand's healthcare systems. As part of the systems strengthening arsenal, the Tool can stimulate debate about the merits and consequences of different healthcare systems structural designs, using a common framework that fosters multi-country comparative analyses. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene.

  15. Quantifying control effort of biological and technical movements: an information-entropy-based approach.

    PubMed

    Haeufle, D F B; Günther, M; Wunner, G; Schmitt, S

    2014-01-01

    In biomechanics and biorobotics, muscles are often associated with reduced movement control effort and simplified control compared to technical actuators. This is based on evidence that the nonlinear muscle properties positively influence movement control. It is, however, open how to quantify the simplicity aspect of control effort and compare it between systems. Physical measures, such as energy consumption, stability, or jerk, have already been applied to compare biological and technical systems. Here a physical measure of control effort based on information entropy is presented. The idea is that control is simpler if a specific movement is generated with less processed sensor information, depending on the control scheme and the physical properties of the systems being compared. By calculating the Shannon information entropy of all sensor signals required for control, an information cost function can be formulated allowing the comparison of models of biological and technical control systems. Exemplarily applied to (bio-)mechanical models of hopping, the method reveals that the required information for generating hopping with a muscle driven by a simple reflex control scheme is only I=32 bits versus I=660 bits with a DC motor and a proportional differential controller. This approach to quantifying control effort captures the simplicity of a control scheme and can be used to compare completely different actuators and control approaches.

  16. Health system frameworks and performance indicators in eight countries: A comparative international analysis

    PubMed Central

    Braithwaite, Jeffrey; Hibbert, Peter; Blakely, Brette; Plumb, Jennifer; Hannaford, Natalie; Long, Janet Cameron; Marks, Danielle

    2017-01-01

    Objectives: Performance indicators are a popular mechanism for measuring the quality of healthcare to facilitate both quality improvement and systems management. Few studies make comparative assessments of different countries’ performance indicator frameworks. This study identifies and compares frameworks and performance indicators used in selected Organisation for Economic Co-operation and Development health systems to measure and report on the performance of healthcare organisations and local health systems. Countries involved are Australia, Canada, Denmark, England, the Netherlands, New Zealand, Scotland and the United States. Methods: Identification of comparable international indicators and analyses of their characteristics and of their broader national frameworks and contexts were undertaken. Two dimensions of indicators – that they are nationally consistent (used across the country rather than just regionally) and locally relevant (measured and reported publicly at a local level, for example, a health service) – were deemed important. Results: The most commonly used domains in performance frameworks were safety, effectiveness and access. The search found 401 indicators that fulfilled the ‘nationally consistent and locally relevant’ criteria. Of these, 45 indicators are reported in more than one country. Cardiovascular, surgery and mental health were the most frequently reported disease groups. Conclusion: These comparative data inform researchers and policymakers internationally when designing health performance frameworks and indicator sets. PMID:28228948

  17. Comparative study between the reflective optics and lens based system for microwave imaging system on KSTAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, W.; Yun, G. S.; Nam, Y.

    2010-10-15

    Recently, two-dimensional microwave imaging diagnostics such as the electron cyclotron emission imaging (ECEI) system and microwave imaging reflectometry (MIR) have been developed to study magnetohydrodynamics instabilities and turbulence in magnetically confined plasmas. These imaging systems utilize large optics to collect passive emission or reflected radiation. The design of this optics can be classified into two different types: reflective or refractive optical systems. For instance, an ECEI/MIR system on the TEXTOR tokamak [Park et al., Rev. Sci. Instrum. 75, 3787 (2004)] employed the reflective optics which consisted of two large mirrors, while the TEXTOR ECEI upgrade [B. Tobias et al., Rev.more » Sci. Instrum. 80, 093502 (2009)] and systems on DIII-D, ASDEX-U, and KSTAR adopted refractive systems. Each system has advantages and disadvantages in the standing wave problem and optical aberrations. In this paper, a comparative study between the two optical systems has been performed in order to design a MIR system for KSTAR.« less

  18. High Voltage Distribution System (HVDS) as a better system compared to Low Voltage Distribution System (LVDS) applied at Medan city power network

    NASA Astrophysics Data System (ADS)

    Dinzi, R.; Hamonangan, TS; Fahmi, F.

    2018-02-01

    In the current distribution system, a large-capacity distribution transformer supplies loads to remote locations. The use of 220/380 V network is nowadays less common compared to 20 kV network. This results in losses due to the non-optimal distribution transformer, which neglected the load location, poor consumer profile, and large power losses along the carrier. This paper discusses how high voltage distribution systems (HVDS) can be a better system used in distribution networks than the currently used distribution system (Low Voltage Distribution System, LVDS). The proposed change of the system into the new configuration is done by replacing a large-capacity distribution transformer with some smaller-capacity distribution transformers and installed them in positions that closest to the load. The use of high voltage distribution systems will result in better voltage profiles and fewer power losses. From the non-technical side, the annual savings and payback periods on high voltage distribution systems will also be the advantage.

  19. Clinical, Ergonomic, and Economic Outcomes With Multichamber Bags Compared With (Hospital) Pharmacy Compounded Bags and Multibottle Systems: A Systematic Literature Review.

    PubMed

    Alfonso, Jorge Emilio; Berlana, David; Ukleja, Andrew; Boullata, Joseph

    2017-09-01

    Multichamber bags (MCBs) may offer potential clinical, ergonomic, and economic advantages compared with (hospital) pharmacy compounded bags (COBs) and multibottle systems (MBSs). A systematic literature review was performed to identify and assess the available evidence regarding advantages of MCBs compared with COBs and MBSs. Medline, Embase, the Cochrane Databases, and EconLit were searched for articles reporting clinical, ergonomic, and economic outcomes for MCBs compared with COBs or MBSs. The search was limited to studies conducted in hospitalized patients >2 years of age that were published in English between January 1990 and November 2014. The Population Intervention Comparison Outcomes Study Design (PICOS) framework was used for the analysis. From 1307 unique citations, 74 potentially relevant publications were identified; review of references identified 2 additional publications. Among the 76 publications, 18 published studies met the inclusion criteria. Most were retrospective in design. Ten studies reported clinical outcomes, including 1 prospective randomized trial and multiple retrospective analyses that reported a lower risk of bloodstream infection for MCBs compared with other delivery systems. Sixteen studies reported ergonomic and/or economic outcomes; most reported a potential cost benefit for MCBs, with consistent reports of reduced time and labor compared with other systems. The largest cost benefit was observed in studies evaluating total hospitalization costs. The systematic literature review identified evidence of potential clinical, ergonomic, and economic benefits for MCBs compared with COBs and MBSs; however, methodological factors limited evidence quality. More prospective studies are required to corroborate existing evidence.

  20. A study of renal function influence by integrating cloud-based manometers and physician order entry systems.

    PubMed

    Lin, Yuh-Feng; Sheng, Li-Huei; Wu, Mei-Yi; Zheng, Cai-Mei; Chang, Tian-Jong; Li, Yu-Chuan; Huang, Yu-Hui; Lu, Hsi-Peng

    2014-12-01

    No evidence exists from randomized trials to support using cloud-based manometers integrated with available physician order entry systems for tracking patient blood pressure (BP) to assist in the control of renal function deterioration. We investigated how integrating cloud-based manometers with physician order entry systems benefits our outpatient chronic kidney disease patients compared with typical BP tracking systems. We randomly assigned 36 chronic kidney disease patients to use cloud-based manometers integrated with physician order entry systems or typical BP recording sheets, and followed the patients for 6 months. The composite outcome was that the patients saw improvement both in BP and renal function. We compared the systolic and diastolic BP (SBP and DBP), and renal function of our patients at 0 months, 3 months, and 6 months after using the integrated manometers and typical BP monitoring sheets. Nighttime SBP and DBP were significantly lower in the study group compared with the control group. Serum creatinine level in the study group improved significantly compared with the control group after the end of Month 6 (2.83 ± 2.0 vs. 4.38 ± 3.0, p = 0.018). Proteinuria improved nonsignificantly in Month 6 in the study group compared with the control group (1.05 ± 0.9 vs. 1.90 ± 1.3, p = 0.09). Both SBP and DBP during the nighttime hours improved significantly in the study group compared with the baseline. In pre-end-stage renal disease patients, regularly monitoring BP by integrating cloud-based manometers appears to result in a significant decrease in creatinine and improvement in nighttime BP control. Estimated glomerular filtration rate and proteinuria were found to be improved nonsignificantly, and thus, larger population and longer follow-up studies may be needed.

  1. Performance characteristics of dedicated molecular breast imaging systems at low doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Zaiyang; Conners, Amy L.; Hunt, Katie N.

    Purpose: The purpose of this study was to compare the system performance characteristics and lesion detection capability of two molecular breast imaging (MBI) systems: a multicrystal sodium iodide (NaI)-based single-head system and a cadmium zinc telluride (CZT)-based dual-head system at low administered doses (150–300 MBq) of Tc-99m sestamibi. Methods: System performance characteristics including count sensitivity, uniformity, energy resolution, and spatial resolution were measured using standard NEMA methods, or a modified version thereof in cases where the standard NEMA protocol could not be applied. A contrast-detail phantom with 48 lesions at varying depths from the collimator surface was used to assessmore » lesion contrast-to-noise-ratio (CNR) using background count densities comparable to those observed in patient studies performed with administered doses of 150 MBq Tc-99m sestamibi. Lesions with CNR >3 were deemed to be detectable. Thirty patients undergoing MBI examinations with administered doses of 150–300 MBq were scanned for an additional view on the pixelated NaI system. CNR was calculated for lesions observed on patient images. Background count densities of patient images were measured and compared between the two systems. Results: Over the central field of view, integral and differential uniformity were 6.1% and 4.2%, respectively, for the pixelated NaI system, and 3.8% and 2.7%, respectively, for the CZT system. Count sensitivity was 10.8 kcts/min/MBq for the NaI system and 32.9 kcts/min/MBq for the CZT system. Energy resolution was 13.5% on the pixelated NaI system and 4.5% on the CZT system. Spatial resolution (full-width at half-maximum) for the pixelated NaI detector was 4.2 mm at a distance of 1.2 cm from the collimator and 5.2 mm at 3.1 cm. Spatial resolution of a single CZT detector was 2.9 mm at a distance of 1.2 cm from the collimator and 4.7 mm at 3.1 cm. Effective spatial resolution obtained with dual-head CZT was below 4.7 mm throughout a simulated breast thickness of 6 cm. From contrast-detail phantom images of lesions at distances of 1.5–4.5 cm from the collimator face, the CZT system detected 124 of 144 (86%) of lesions compared to 97 of 144 (67%) with the NaI system. In patient studies, from comparison of the same view with both systems, a total of 7 breast lesions were identified on CZT system in seven patients, and 4 of 7 (57%) were detected on NaI system. Patient image background count densities on the CZT system were on average 3.4 times higher than those on the NaI system. Conclusions: The CZT system demonstrated better uniformity, count sensitivity, spatial resolution, energy resolution, and lesion detection in phantom and patient studies compared to the NaI system. At administered doses of 150–300 MBq Tc-99m sestamibi, patient results obtained with CZT systems may not be directly translatable to NaI systems.« less

  2. Comparative evaluation of monocular augmented-reality display for surgical microscopes.

    PubMed

    Rodriguez Palma, Santiago; Becker, Brian C; Lobes, Louis A; Riviere, Cameron N

    2012-01-01

    Medical augmented reality has undergone much development recently. However, there is a lack of studies quantitatively comparing the different display options available. This paper compares the effects of different graphical overlay systems in a simple micromanipulation task with "soft" visual servoing. We compared positioning accuracy in a real-time visually-guided task using Micron, an active handheld tremor-canceling microsurgical instrument, using three different displays: 2D screen, 3D screen, and microscope with monocular image injection. Tested with novices and an experienced vitreoretinal surgeon, display of virtual cues in the microscope via an augmented reality injection system significantly decreased 3D error (p < 0.05) compared to the 2D and 3D monitors when confounding factors such as magnification level were normalized.

  3. Text mining meets workflow: linking U-Compare with Taverna

    PubMed Central

    Kano, Yoshinobu; Dobson, Paul; Nakanishi, Mio; Tsujii, Jun'ichi; Ananiadou, Sophia

    2010-01-01

    Summary: Text mining from the biomedical literature is of increasing importance, yet it is not easy for the bioinformatics community to create and run text mining workflows due to the lack of accessibility and interoperability of the text mining resources. The U-Compare system provides a wide range of bio text mining resources in a highly interoperable workflow environment where workflows can very easily be created, executed, evaluated and visualized without coding. We have linked U-Compare to Taverna, a generic workflow system, to expose text mining functionality to the bioinformatics community. Availability: http://u-compare.org/taverna.html, http://u-compare.org Contact: kano@is.s.u-tokyo.ac.jp Supplementary information: Supplementary data are available at Bioinformatics online. PMID:20709690

  4. Interpretation Time Using a Concurrent-Read Computer-Aided Detection System for Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breast Tissue.

    PubMed

    Jiang, Yulei; Inciardi, Marc F; Edwards, Alexandra V; Papaioannou, John

    2018-05-24

    The purpose of this study was to compare diagnostic accuracy and interpretation time of screening automated breast ultrasound (ABUS) for women with dense breast tissue without and with use of a recently U.S. Food and Drug Administration-approved computer-aided detection (CAD) system for concurrent read. In a retrospective observer performance study, 18 radiologists interpreted a cancer-enriched set (i.e., cancer prevalence higher than in the original screening cohort) of 185 screening ABUS studies (52 with and 133 without breast cancer). These studies were from a large cohort of ABUS screened patients interpreted as BI-RADS density C or D. Each reader interpreted each case twice in a counterbalanced study, once without the CAD system and once with it, separated by 4 weeks. For each case, each reader identified abnormal findings and reported BI-RADS assessment category and level of suspicion for breast cancer. Interpretation time was recorded. Level of suspicion data were compared to evaluate diagnostic accuracy by means of the Dorfman-Berbaum-Metz method of jackknife with ANOVA ROC analysis. Interpretation times were compared by ANOVA. The ROC AUC was 0.848 with the CAD system, compared with 0.828 without it, for a difference of 0.020 (95% CI, -0.011 to 0.051) and was statistically noninferior to the AUC without the CAD system with respect to a margin of -0.05 (p = 0.000086). The mean interpretation time was 3 minutes 33 seconds per case without the CAD system and 2 minutes 24 seconds with it, for a difference of 1 minute 9 seconds saved (95% CI, 44-93 seconds; p = 0.000014), or a reduction in interpretation time to 67% of the time without the CAD system. Use of the concurrent-read CAD system for interpretation of screening ABUS studies of women with dense breast tissue who do not have symptoms is expected to make interpretation significantly faster and produce noninferior diagnostic accuracy compared with interpretation without the CAD system.

  5. Effect of heating system using a geothermal heat pump on the production performance and housing environment of broiler chickens.

    PubMed

    Choi, H C; Salim, H M; Akter, N; Na, J C; Kang, H K; Kim, M J; Kim, D W; Bang, H T; Chae, H S; Suh, O S

    2012-02-01

    A geothermal heat pump (GHP) is a potential heat source for the economic heating of broiler houses with optimum production performance. An investigation was conducted to evaluate the effect of a heating system using a GHP on production performance and housing environment of broiler chickens. A comparative analysis was also performed between the GHP system and a conventional heating system that used diesel for fuel. In total, 34,000 one-day-old straight run broiler chicks were assigned to 2 broiler houses with 5 replicates in each (3,400 birds/replicate pen) for 35 d. Oxygen(,) CO(2), and NH(3) concentrations in the broiler house, energy consumption and cost of heating, and production performance of broilers were evaluated. Results showed that the final BW gain significantly (P < 0.05) increased when chicks were reared in the GHP broiler house compared with that of chicks reared in the conventional broiler house (1.73 vs. 1.62 kg/bird). The heating system did not affect the mortality of chicks during the first 4 wk of the experimental period, but the mortality markedly increased in the conventional broiler house during the last wk of the experiment. Oxygen content in the broiler house during the experimental period was not affected by the heating system, but the CO(2) and NH(3) contents significantly increased (P < 0.05) in the conventional broiler house compared with those in the GHP house. Fuel consumption was significantly reduced (P < 0.05) and electricity consumption significantly increased (P < 0.05) in the GHP house compared with the consumption in the conventional house during the experiment. The total energy cost of heating the GHP house was significantly lower (P < 0.05) compared with that of the conventional house. It is concluded that a GHP system could increase the production performance of broiler chicks due to increased inside air quality of the broiler house. The GHP system had lower CO(2) and NH(3) emissions with lower energy cost than the conventional heating system for broiler chickens.

  6. The effects of scattering on the relative LPI performance of optical and mm-wave systems

    NASA Astrophysics Data System (ADS)

    Oetting, John; Hampton, Jerry

    1988-01-01

    Previous results comparing the LPI performance of optical and millimeter-wave satellite systems is extended to include the effects of scattering on optical LPI performance. The LPI figure of merit used to compare the two media is the circular equivalent vulnerability radius (CEVR). The CEVR is calculated for typical optical and spread spectrum millimeter-wave systems, and the LPI performance tradeoffs available with each medium are compared. Attention is given to the possibility that light will be scattered into the interceptor's FOV and thereby enable detection in geometries in which interception of the main beam is impossible. The effects of daytime vs. nighttime operation of the optical LPI system are also considered. Some illustrative results for the case of a ground-to-space uplink to a low earth orbit satellite are presented, along with some conclusions and unresolved issues for further study.

  7. Monitoring with Data Automata

    NASA Technical Reports Server (NTRS)

    Havelund, Klaus

    2014-01-01

    We present a form of automaton, referred to as data automata, suited for monitoring sequences of data-carrying events, for example emitted by an executing software system. This form of automata allows states to be parameterized with data, forming named records, which are stored in an efficiently indexed data structure, a form of database. This very explicit approach differs from other automaton-based monitoring approaches. Data automata are also characterized by allowing transition conditions to refer to other parameterized states, and by allowing transitions sequences. The presented automaton concept is inspired by rule-based systems, especially the Rete algorithm, which is one of the well-established algorithms for executing rule-based systems. We present an optimized external DSL for data automata, as well as a comparable unoptimized internal DSL (API) in the Scala programming language, in order to compare the two solutions. An evaluation compares these two solutions to several other monitoring systems.

  8. The accuracy of real-time procedure coding by theatre nurses: a comparison with the central national system.

    PubMed

    Maclean, Donald; Younes, Hakim Ben; Forrest, Margaret; Towers, Hazel K

    2012-03-01

    Accurate and timely clinical data are required for clinical and organisational purposes and is especially important for patient management, audit of surgical performance and the electronic health record. The recent introduction of computerised theatre management systems has enabled real-time (point-of-care) operative procedure coding by clinical staff. However the accuracy of these data is unknown. The aim of this Scottish study was to compare the accuracy of theatre nurses' real-time coding on the local theatre management system with the central Scottish Morbidity Record (SMR01). Paired procedural codes were recorded, qualitatively graded for precision and compared (n = 1038). In this study, real-time, point-of-care coding by theatre nurses resulted in significant coding errors compared with the central SMR01 database. Improved collaboration between full-time coders and clinical staff using computerised decision support systems is suggested.

  9. The Salmonella dublin virulence plasmid mediates systemic but not enteric phases of salmonellosis in cattle.

    PubMed Central

    Wallis, T S; Paulin, S M; Plested, J S; Watson, P R; Jones, P W

    1995-01-01

    Plasmid-bearing and plasmid-free isolates and a plasmid-cured strain of Salmonella dublin were compared for virulence in calves. The plasmid-bearing strains were highly virulent, causing severe enteric and systemic disease with high mortality. In contrast, the plasmid-free strains caused diarrhea but only low mortality. The infection kinetics of a wild-type and a derivative plasmid-cured strain were compared. Both strains were isolated in high numbers from intestinal sites at 3 and 6 days after oral challenge and were isolated at comparable frequencies from systemic sites at 3 days, but not at 6 days, when the wild-type strain was predominant. The strains were equally invasive in intestinal epithelia with and without Peyer's patch and elicited comparable secretory and inflammatory responses and intestinal pathology in ligated ileal loops. The effect of the virulence plasmid on growth kinetics and on the outer membrane protein profile was assessed in an in vivo growth chamber. The virulence plasmid did not influence either extracellular growth or the expression of major outer membrane proteins. These observations demonstrate that the virulence plasmid is not involved in either the enteric phase of infection or the systemic dissemination of S. dublin but probably mediates the persistence of S. dublin at systemic sites. PMID:7790094

  10. The Treatment of Scabies.

    PubMed

    Dressler, Corinna; Rosumeck, Stefanie; Sunderkötter, Cord; Werner, Ricardo Niklas; Nast, Alexander

    2016-11-14

    Scabies is a contagious infestation transmitted by skin-to-skin contact and sometimes by contact with contaminated material. The scabies mite burrows into the skin, producing a papular rash and severe itch at typical sites of predilection. We systematically reviewed the literature to compare the efficacy of various anti-scabies agents, including a calculation of relative risks and confidence intervals. A literature search yielded 596 initial hits; after screening in accor-dance with the defined inclusion and exclusion criteria, 16 studies were selected for this review. Among topical treatments for scabies, permethrin was equally effective or more effective than crotamiton or benzyl benzoate. In a comparison of topical versus systemic treatment, topical permethrin and systemic ivermectin did not differ substantially in efficacy (7 comparative studies revealed no difference; one revealed a difference in favor of permethrin). Comparative trials of topical benzyl benzoate versus systemic ivermectin yielded inconsistent findings. Single and double administrations of ivermectin were similarly effective. In trials involving entire populations with a high prevalence of scabies, systemic ivermectin was found to be superior to topical permethrin. There are hardly any differences in efficacy between the available treatments for scabies. Single administrations of permethrin 5%, crotamiton 10%, and systemic ivermectin are all comparably effective. There are differences in the frequeny and ease of application as well as when eradicating scabies in populations with a high prevalence.

  11. Airflow obstruction, atherosclerosis and cardiovascular risk factors in the AGES Reykjavik study.

    PubMed

    Gudmundsson, Gunnar; Margretardottir, Olof Birna; Sigurdsson, Martin Ingi; Harris, Tamara B; Launer, Lenore J; Sigurdsson, Sigurdur; Olafsson, Orn; Aspelund, Thor; Gudnason, Vilmundur

    2016-09-01

    Airflow limitation, i.e. reduced forced expiratory volume in 1-s (FEV1), is associated with increased prevalence of atherosclerosis, however, causal mechanisms remain elusive. The objective of the study was to determine if the association between airflow obstruction and markers of atherosclerosis is mediated by systemic inflammation. 1154 subjects from the longitudinal AGES Reykjavik study were included. Population characteristics, systemic inflammation markers from blood (white blood cell counts (WBC) and level of C-reactive protein (CRP)) were compared between patients with and without airflow limitation defined by reduced FEV1 on spirometry. Atherosclerosis burden was quantified by measurements of coronary artery calcium, aortic arch and distal aortic calcification in addition to carotid intimal media thickness (CIMT). Subjects were split into four groups according to smoking status and whether airflow limitation was present. There was a higher overall burden of atherosclerosis in ever-smokers compared to never-smokers, and in individuals with airflow obstruction compared to individuals without airflow obstruction. After adjusting for population characteristics, Framingham cardiovascular risk factors and markers of systemic inflammation (WBC and CRP), there was a significantly increased aortic arch and distal aorta calcification and higher CIMT measurement in individuals with airflow obstruction compared to individuals without airflow obstruction. After adjusting for population characteristics, Framingham cardiovascular risk factors and markers of systemic inflammation (WBC and CRP), there was a significantly increased aortic arch and distal aorta calcification and higher CIMT measurement in individuals with airflow obstruction compared to individuals without airflow obstruction. Systemic inflammation (WBC and CRP) does not appear to mediate the association between airflow limitation and atherosclerosis. Only airflow limitation and not systemic inflammation (WBC and CRP) appears to be an independent predictor of atherosclerosis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Taking advantage of public reporting: An infection composite score to assist evaluating hospital performance for infection prevention efforts.

    PubMed

    Fakih, Mohamad G; Skierczynski, Boguslow; Bufalino, Angelo; Groves, Clariecia; Roberts, Phillip; Heavens, Michelle; Hendrich, Ann; Haydar, Ziad

    2016-12-01

    The standardized infection ratio (SIR) evaluates individual publicly reported health care-associated infections, but it may not assess overall performance. We piloted an infection composite score (ICS) in 82 hospitals of a single health system. The ICS is a combined score for central line-associated bloodstream infections, catheter-associated urinary tract infections, colon and abdominal hysterectomy surgical site infections, and hospital-onset methicillin-resistant Staphylococcus aureus bacteremia and Clostridium difficile infections. Individual facility ICSs were calculated by normalizing each of the 6 SIR events to the system SIR for baseline and performance periods (ICS ib and ICS ip , respectively). A hospital ICS ib reflected its baseline performance compared with system baseline, whereas a ICS ip provided information of its outcome changes compared with system baseline. Both the ICS ib (baseline 2013) and ICS ip (performance 2014) were calculated for 63 hospitals (reporting at least 4 of the 6 event types). The ICS ip improved in 36 of 63 (57.1%) hospitals in 2014 when compared with the ICS ib in 2013. The ICS ib 2013 median was 0.96 (range, 0.13-2.94) versus the 2014 ICS ip median of 0.92 (range, 0-6.55). Variation was more evident in hospitals with ≤100 beds. The system performance score (ICS sp ) in 2014 was 0.95, a 5% improvement compared with 2013. The proposed ICS may help large health systems and state hospital associations better evaluate key infectious outcomes, comparing them with historic and concurrent performance of peers. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. Microbiological quality of food in relation to hazard analysis systems and food hygiene training in UK catering and retail premises.

    PubMed

    Little, C L; Lock, D; Barnes, J; Mitchell, R T

    2003-09-01

    A meta-analysis of eight UK food studies was carried out to determine the microbiological quality of food and its relationship with the presence in food businesses of hazard analysis systems and food hygiene training. Of the 19,022 premises visited to collect food samples in these studies between 1997 and 2002, two thirds (66%) were catering premises and one third (34%) were retail premises. Comparison with PHLS Microbiological Guidelines revealed that significantly more ready-to-eat food samples from catering premises (20%; 2,511/12,703) were of unsatisfactory or unacceptable microbiological quality compared to samples from retail premises (12%; 1,039/8,462) (p < 0.00001). Three quarters (76%) of retail premises had hazard analysis systems in place compared with 59% of catering premises (p < 0.00001). In 87% of retail premises the manager had received some form of food hygiene training compared with 80% of catering premises (p < 0.00001). From premises where the manager had received no food hygiene training a greater proportion of samples were of unsatisfactory and unacceptable microbiological quality (20% retail, 27% catering) compared with premises where the manager had received food hygiene training (11% retail, 19% catering) (p < 0.00001). Where the manager of the premises had received food hygiene training, documented hazard analysis systems were more likely to be in place (p < 0.00001). Higher proportions of samples of unsatisfactory and unacceptable microbiological quality (17% retail, 22% catering) were from premises where there was no hazard analysis system in place compared to premises that had a documented hazard analysis system in place (10% retail, 18% catering) (p < 0.00001). Our meta-analysis suggests that the lower microbiological quality of ready-to-eat foods from catering premises compared with those collected from retail premises may reflect differences in management food hygiene training and the presence of a hazard analysis system. The importance of adequate training for food handlers and their managers as a pre-requisite for effective hazard analysis and critical control point (HACCP) based controls is therefore emphasised.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fishkind, H.H.

    The overall environmental impact of the eucalyptus to methanol energy system in Florida is assessed. The environmental impacts associated with the following steps of the process are considered: (1) the greenhouse and laboratory; (2) the eucalyptus plantation; (3) transporting the mature logs; (4) the hammermill; and (5) the methanol synthesis plant. Next, the environmental effects of methanol as an undiluted motor fuel, methanol as a gasoline blend, and gasoline as motor fuels are compared. Finally, the environmental effects of the eucalypt gasification/methanol synthesis system are compared to the coal liquefaction and conversion system.

  15. Etude Comparative des Systemes de Reperage de l'Information Bibliographique en Mode Dialogue. Rapports de Recherche, No. 13 (Comparative Study of Systems for the Online Retrieval of Bibliographic Information. Research Report No. 13).

    ERIC Educational Resources Information Center

    Perusse, Lyse

    This study, which was conducted at the University of Quebec over a period of six months, focuses on four systems for online information retrieval that are available to users at the university and provide access to some of the same databases: BRS (Bibliographic Retrieval Services Inc.), CAN/OLE (Canadian On-Line Inquiry), Lockheed DIALOG, and…

  16. Investigation of a Photovoltaic/Battery Hybrid System for Powering the High Arctic Data Communications System

    DTIC Science & Technology

    1989-08-01

    installation of amp-hour meters. 3. Evaluation of th6 low temperature performanceof Willard DH-5 pure lead batteries. b. Evaluation of the low...was abnormallyI low. This is seen in Table 7 which compares the solar radiation data received during this three year period with the 30 year averages...operational hour. This can be compared with a requirement for powering the microwave repeaters of about 2Ah/hour assuming a system voltage of 15V

  17. A comparative overview of modal testing and system identification for control of structures

    NASA Technical Reports Server (NTRS)

    Juang, J.-N.; Pappa, R. S.

    1988-01-01

    A comparative overview is presented of the disciplines of modal testing used in structural engineering and system identification used in control theory. A list of representative references from both areas is given, and the basic methods are described briefly. Recent progress on the interaction of modal testing and control disciplines is discussed. It is concluded that combined efforts of researchers in both disciplines are required for unification of modal testing and system identification methods for control of flexible structures.

  18. Gait Biomechanics of Individuals with Transtibial Amputation: Effect of Suspension System

    PubMed Central

    Eshraghi, Arezoo; Abu Osman, Noor Azuan; Karimi, Mohammad; Gholizadeh, Hossein; Soodmand, Ehsan; Abas, Wan Abu Bakar Wan

    2014-01-01

    Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic gait parameters during level walking with the new suspension system as well as two other commonly used systems (the Seal-In and pin/lock). Thirteen persons with transtibial amputation participated in this study. A Vicon motion system (six cameras, two force platforms) was utilized to obtain gait kinetic and kinematic variables, as well as pistoning within the prosthetic socket. The gait deviation index was also calculated based on the kinematic data. The findings indicated significant difference in the pistoning values among the three suspension systems. The Seal-In system resulted in the least pistoning compared with the other two systems. Several kinetic and kinematic variables were also affected by the suspension type. The ground reaction force data showed that lower load was applied to the limb joints with the magnetic suspension system compared with the pin/lock suspension. The gait deviation index showed significant deviation from the normal with all the systems, but the systems did not differ significantly. Main significant effects of the suspension type were seen in the GRF (vertical and fore-aft), knee and ankle angles. The new magnetic suspension system showed comparable effects in the remaining kinetic and kinematic gait parameters to the other studied systems. This study may have implications on the selection of suspension systems for transtibial prostheses. Trial Registration Iranian Registry of Clinical Trials IRCT2013061813706N1. PMID:24865351

  19. Evaluation of load flow and grid expansion in a unit-commitment and expansion optimization model SciGRID International Conference on Power Grid Modelling

    NASA Astrophysics Data System (ADS)

    Senkpiel, Charlotte; Biener, Wolfgang; Shammugam, Shivenes; Längle, Sven

    2018-02-01

    Energy system models serve as a basis for long term system planning. Joint optimization of electricity generating technologies, storage systems and the electricity grid leads to lower total system cost compared to an approach in which the grid expansion follows a given technology portfolio and their distribution. Modelers often face the problem of finding a good tradeoff between computational time and the level of detail that can be modeled. This paper analyses the differences between a transport model and a DC load flow model to evaluate the validity of using a simple but faster transport model within the system optimization model in terms of system reliability. The main findings in this paper are that a higher regional resolution of a system leads to better results compared to an approach in which regions are clustered as more overloads can be detected. An aggregation of lines between two model regions compared to a line sharp representation has little influence on grid expansion within a system optimizer. In a DC load flow model overloads can be detected in a line sharp case, which is therefore preferred. Overall the regions that need to reinforce the grid are identified within the system optimizer. Finally the paper recommends the usage of a load-flow model to test the validity of the model results.

  20. Development of a rocking R/C shear wall system implementing repairable structural fuses

    NASA Astrophysics Data System (ADS)

    Parsafar, Saeed; Moghadam, Abdolreza S.

    2017-09-01

    In the last decades, the concept of earthquake resilient structural systems is becoming popular in which the rocking structure is considered as a viable option for buildings in regions of high seismicity. To this end, a novel wall-base connection based on the " repairable structure" approach is proposed and evaluated. The proposed system is made of several steel plates and high strength bolts act as a friction connection. To achieve the desired rocking motion in the proposed system, short-slotted holes are used in vertical directions for connecting the steel plates to the shear wall (SW). The experimental and numerical studies were performed using a series of displacement control quasi-static cyclic tests on a reference model and four different configurations of the proposed connection installed at the wall corners. The seismic response of the proposed system is compared to the conventional SW in terms of energy dissipation and damage accumulation. In terms of energy dissipation, the proposed system depicted better performance with 95% more energy dissipation capability compared to conventional SW. In terms of damage accumulation, the proposed SW system is nearly undamaged compared to the conventional wall system, which was severely damaged at the wall-base region. Overall, the introduced concept presents a feasible solution for R/C structures when a low-damage design is targeted, which can improve the seismic performance of the structural system significantly.

Top