Sample records for bacteria total coliform

  1. The Interaction between Heterotrophic Bacteria and Coliform, Fecal Coliform, Fecal Streptococci Bacteria in the Water Supply Networks.

    PubMed

    Amanidaz, Nazak; Zafarzadeh, Ali; Mahvi, Amir Hossein

    2015-12-01

    This study investigated the interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in water supply networks. This study was conducted during 2013 on water supply distribution network in Aq Qala City, Golestan Province, Northern Iran and standard methods were applied for microbiological analysis. The surface method was applied to test the heterotrophic bacteria and MPN method was used for coliform, fecal coliform and fecal streptococci bacteria measurements. In 114 samples, heterotrophic bacteria count were over 500 CFU/ml, which the amount of fecal coliform, coliform, and fecal streptococci were 8, 32, and 20 CFU/100 ml, respectively. However, in the other 242 samples, with heterotrophic bacteria count being less than 500 CFU/ml, the amount of fecal coliform, coliform, and fecal streptococci was 7, 23, and 11 CFU/100ml, respectively. The relationship between heterotrophic bacteria, coliforms and fecal streptococci was highly significant (P<0.05). We observed the concentration of coliforms, fecal streptococci bacteria being high, whenever the concentration of heterotrophic bacteria in the water network systems was high. Interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in the Aq Qala City water supply networks was not notable. It can be due to high concentrations of organic carbon, bio-films and nutrients, which are necessary for growth, and survival of all microorganisms.

  2. The Interaction between Heterotrophic Bacteria and Coliform, Fecal Coliform, Fecal Streptococci Bacteria in the Water Supply Networks

    PubMed Central

    AMANIDAZ, Nazak; ZAFARZADEH, Ali; MAHVI, Amir Hossein

    2015-01-01

    Background: This study investigated the interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in water supply networks. Methods: This study was conducted during 2013 on water supply distribution network in Aq Qala City, Golestan Province, Northern Iran and standard methods were applied for microbiological analysis. The surface method was applied to test the heterotrophic bacteria and MPN method was used for coliform, fecal coliform and fecal streptococci bacteria measurements. Results: In 114 samples, heterotrophic bacteria count were over 500 CFU/ml, which the amount of fecal coliform, coliform, and fecal streptococci were 8, 32, and 20 CFU/100 ml, respectively. However, in the other 242 samples, with heterotrophic bacteria count being less than 500 CFU/ml, the amount of fecal coliform, coliform, and fecal streptococci was 7, 23, and 11 CFU/100ml, respectively. The relationship between heterotrophic bacteria, coliforms and fecal streptococci was highly significant (P<0.05). We observed the concentration of coliforms, fecal streptococci bacteria being high, whenever the concentration of heterotrophic bacteria in the water network systems was high. Conclusion: Interaction between heterotrophic bacteria and coliform, fecal coliforms, fecal streptococci bacteria in the Aq Qala City water supply networks was not notable. It can be due to high concentrations of organic carbon, bio-films and nutrients, which are necessary for growth, and survival of all microorganisms. PMID:26811820

  3. Bacteria holding times for fecal coliform by mFC agar method and total coliform and Escherichia coli by Colilert®-18 Quanti-Tray® method

    USGS Publications Warehouse

    Aulenbach, Brent T.

    2010-01-01

    Bacteria holding-time experiments of up to 62 h were performed on five surface-water samples from four urban stream sites in the vicinity of Atlanta, GA, USA that had relatively high densities of coliform bacteria (Escherichia coli densities were all well above the US Environmental Protection Agency criterion of 126 colonies (100 ml) − 1 for recreational waters). Holding-time experiments were done for fecal coliform using the membrane filtration modified fecal coliform (mFC) agar method and for total coliform and E. coli using the Colilert®-18 Quanti-Tray® method. The precisions of these analytical methods were quantified. Precisions determined for fecal coliform indicated that the upper bound of the ideal range of counts could reasonably be extended upward and would improve precision. For the Colilert®-18 method, analytical precisions were similar to the theoretical precisions for this method. Fecal and total coliform densities did not change significantly with holding times up to about 27 h. Limited information indicated that fecal coliform densities might be stable for holding times of up to 62 h, whereas total coliform densities might not be stable for holding times greater than about 27 h. E. coli densities were stable for holding times of up to 18 h—a shorter period than indicated from a previous studies. These results should be applicable to non-regulatory monitoring sampling designs for similar urban surface-water sample types.

  4. Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

    PubMed Central

    Newman, Judith S.; O'Brien, R. T.

    1975-01-01

    A gas chromatographic procedure which shows promise as a presumptive test for coliform bacteria in water is described. Total coliform bacteria concentrations were determined from the incubation times at 37 C required for ethanol to be produced. Fecal coliform densities were determined in a similar manner at 44.5 C. The culture medium was filter sterilized M-9 salts supplemented with 1% lactose, 0.1% Casamino Acids, and 0.1% yeast extract. Best results were obtained when the initial total coliform concentrations were 5 per ml or higher and when fecal coliform concentrations were 50 per ml or higher. Minimum detection times at these concentrations were 9 and 12 h, respectively. PMID:1103731

  5. Inactivation and injury of total coliform bacteria after primary disinfection of drinking water by TiO2 photocatalysis.

    PubMed

    Rizzo, Luigi

    2009-06-15

    In this study the potential application of TiO(2) photocatalysis as primary disinfection system of drinking water was investigated in terms of coliform bacteria inactivation and injury. As model water the effluent of biological denitrification unit for nitrate removal from groundwater, which is characterized by high organic matter and bacteria release, was used. The injury of photocatalysis on coliform bacteria was characterized by means of selective (mEndo) and less selective (mT7) culture media. Different catalyst loadings as well as photolysis and adsorption effects were investigated. Photocatalysis was effective in coliform bacteria inactivation (91-99% after 60 min irradiation time, depending on both catalyst loading and initial density of coliform bacteria detected by mEndo), although no total removal was observed after 60 min irradiation time. The contribution of adsorption mechanism was significant (60-98% after 60 min, depending on catalyst loading) compared to previous investigations probably due to the nature of source water rich in particulate organic matter and biofilm. Photocatalysis process did not result in any irreversible injury (98.8% being the higher injury) under investigated conditions, thus a bacteria regrowth may take place under optimum environment conditions if any final disinfection process (e.g., chlorine or chlorine dioxide) is not used.

  6. [Comparison of techniques for coliform bacteria extraction from sediment of Xochimilco Lake, Mexico].

    PubMed

    Fernández-Rendón, Carlos L; Barrera-Escorcia, Guadalupe

    2013-01-01

    The need to separate bacteria from sediment in order to appropriately count them has led to test the efficacy of different techniques. In this research, traditional techniques such as manual shaking, homogenization, ultrasonication, and surfactant are compared. Moreover, the possibility of using a set of enzymes (pancreatine) and an antibiotic (ampicillin) for sediment coliform extraction is proposed. Samples were obtained from Xochimilco Lake in Mexico City. The most probable number of coliform bacteria was determined after applying the appropriate separation procedure. Most of the techniques tested led to numbers similar to those of the control (manual shaking). Only with the use of ampicillin, a greater total coliform concentration was observed (Mann-Whitney, z = 2.09; p = 0.03). It is possible to propose the use of ampicillin as a technique for total coliform extraction; however, it is necessary to consider sensitivity of bacteria to the antibiotic.

  7. Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources.

    PubMed

    Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam

    2017-01-01

    Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli . PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources.

  8. Development of multiplex PCR for the detection of total coliform bacteria for Escherichia coli and Clostridium perfringens in drinking water.

    PubMed

    Tantawiwat, Suwalee; Tansuphasiri, Unchalee; Wongwit, Waranya; Wongchotigul, Varee; Kitayaporn, Dwip

    2005-01-01

    Multiplex PCR amplification of lacZ, uidA and plc genes was developed for the simultaneous detection of total coliform bacteria for Escherichia coli and Clostridium perfringens, in drinking water. Detection by agarose gel electrophoresis yielded a band of 876 bp for the lacZ gene of all coliform bacteria; a band of 147 bp for the uidA gene and a band of 876 bp for the lacZ gene of all strains of E. coli; a band of 280 bp for the p/c gene for all strains of C. perfringens; and a negative result for all three genes when tested with other bacteria. The detection limit was 100 pg for E. coli and C. perfringens, and 1 ng for coliform bacteria when measured with purified DNA. This assay was applied to the detection of these bacteria in spiked water samples. Spiked water samples with 0-1,000 CFU/ml of coliform bacteria and/or E. coli and/or C. perfringens were detected by this multiplex PCR after a pre-enrichment step to increase the sensitivity and to ensure that the detection was based on the presence of cultivable bacteria. The result of bacterial detection from the multiplex PCR was comparable with that of a standard plate count on selective medium (p=0.62). When using standard plate counts as a gold standard, the sensitivity for this test was 99.1% (95% CI 95.33, 99.98) and the specificity was 90.9 % (95% CI 75.67, 98.08). Multiplex PCR amplification with a pre-enrichment step was shown to be an effective, sensitive and rapid method for the simultaneous detection of these three microbiological parameters in drinking water.

  9. Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources

    PubMed Central

    Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam

    2017-01-01

    Background: Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Materials and Methods: Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Results: Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli. PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. Conclusion: The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources. PMID:29142893

  10. Asellus aquaticus as a Potential Carrier of Escherichia coli and Other Coliform Bacteria into Drinking Water Distribution Systems

    PubMed Central

    Christensen, Sarah C. B.; Arvin, Erik; Nissen, Erling; Albrechtsen, Hans-Jørgen

    2013-01-01

    Individuals of the water louse, Asellus aquaticus, enter drinking water distribution systems in temperate parts of the world, where they establish breeding populations. We analysed populations of surface water A. aquaticus from two ponds for associated faecal indicator bacteria and assessed the risk of A. aquaticus transporting bacteria into distribution systems. Concentrations of up to two E. coli and five total coliforms·mL−1 were measured in the water and 200 E. coli and >240 total coliforms·mL−1 in the sediments of the investigated ponds. Concentrations of A. aquaticus associated bacteria never exceeded three E. coli and six total coliforms·A. aquaticus−1. During exposure to high concentrations of coliforms, concentrations reached 350 coliforms·A. aquaticus−1. A. aquaticus associated E. coli were only detected as long as E. coli were present in the water and sediment. The calculated probability of exceeding drinking water guideline values in non-disinfected systems by intrusion of A. aquaticus was low. Only in scenarios with narrow pipes and low flows, did total coliforms exceed guideline values, implying that the probability of detection by routine monitoring is also low. The study expands the knowledge base for evaluating incidents with presence of coliform indicators in drinking water by showing that intruding A. aquaticus were not important carriers of E. coli or other coliform bacteria even when emerging from faecally contaminated waters. PMID:23455399

  11. Asellus aquaticus as a potential carrier of Escherichia coli and other coliform bacteria into drinking water distribution systems.

    PubMed

    Christensen, Sarah C B; Arvin, Erik; Nissen, Erling; Albrechtsen, Hans-Jørgen

    2013-03-01

    Individuals of the water louse, Asellus aquaticus, enter drinking water distribution systems in temperate parts of the world, where they establish breeding populations. We analysed populations of surface water A. aquaticus from two ponds for associated faecal indicator bacteria and assessed the risk of A. aquaticus transporting bacteria into distribution systems. Concentrations of up to two E. coli and five total coliforms·mL-1 were measured in the water and 200 E. coli and >240 total coliforms·mL-1 in the sediments of the investigated ponds. Concentrations of A. aquaticus associated bacteria never exceeded three E. coli and six total coliforms·A. aquaticus-1. During exposure to high concentrations of coliforms, concentrations reached 350 coliforms·A. aquaticus-1. A. aquaticus associated E. coli were only detected as long as E. coli were present in the water and sediment. The calculated probability of exceeding drinking water guideline values in non-disinfected systems by intrusion of A. aquaticus was low. Only in scenarios with narrow pipes and low flows, did total coliforms exceed guideline values, implying that the probability of detection by routine monitoring is also low. The study expands the knowledge base for evaluating incidents with presence of coliform indicators in drinking water by showing that intruding A. aquaticus were not important carriers of E. coli or other coliform bacteria even when emerging from faecally contaminated waters.

  12. Movement of coliform bacteria and nutrients in ground water flowing through basalt and sand aquifers.

    PubMed

    Entry, J A; Farmer, N

    2001-01-01

    Large-scale deposition of animal manure can result in contamination of surface and ground water and in potential transfer of disease-causing enteric bacteria to animals or humans. We measured total coliform bacteria (TC), fecal coliform bacteria (FC), NO3, NH4, total P, and PO4 in ground water flowing from basalt and sand aquifers, in wells into basalt and sand aquifers, in irrigation water, and in river water. Samples were collected monthly for 1 yr. Total coliform and FC numbers were always higher in irrigation water than in ground water, indicating that soil and sediment filtered most of these bacteria before they entered the aquifers. Total coliform and FC numbers in ground water were generally higher in the faster flowing basalt aquifer than in the sand aquifer, indicating that the slower flow and finer grain size may filter more TC and FC bacteria from water. At least one coliform bacterium/100 mL of water was found in ground water from both basalt and sand aquifers, indicating that ground water pumped from these aquifers is not necessarily safe for human consumption according to the American Public Health Association and the USEPA. The NO3 concentrations were usually higher in water flowing from the sand aquifer than in water flowing from the basalt aquifer or in perched water tables in the basalt aquifer. The PO4 concentrations were usually higher in water flowing from the basalt aquifer than in water flowing from the sand aquifer. The main concern is fecal contamination of these aquifers and health consequences that may arise from human consumption.

  13. Comparison of media for enumeration of coliform bacteria and Escherichia coli in non-disinfected water.

    PubMed

    Pitkänen, Tarja; Paakkari, Piia; Miettinen, Ilkka T; Heinonen-Tanski, Helvi; Paulin, Lars; Hänninen, Marja-Liisa

    2007-03-01

    In this work alternative media for detection and enumeration of E. coli and coliform bacteria were compared to the reference method ISO 9308-1 (LTTC) using non-disinfected water samples with background flora. The alternative media included LES Endo agar medium (LES Endo), Colilert-18 with 51-well Quanti-tray (Colilert), Chromocult Coliform agar (CC), Harlequin E. coli/Coliform medium (HECM) and Chromogenic Escherichia coli/Coliform medium (CECM). A total of 110 samples of groundwater, bathing water and spiked water was used. Our results revealed that confirmation of coliform bacteria counts is necessary, not only on lactose-based LTTC and LES Endo media, but also on the chromogenic agar media tested, due to the growth of oxidase positive colonies. LTTC and CC media also allowed the growth of some morphologically typical coliform colonies containing gram-positive bacteria. The recovery of coliform bacteria was lower on LES Endo than on LTTC. In most cases Colilert, CC, HECM and CECM gave higher coliform counts than LTTC. The use of the LTTC medium led to higher E. coli counts than obtained with any of the alternative mediums. There are three explanations for this: (1) high sensitivity of LTTC, (2) false positives on LTTC or (3) false negatives especially with Colilert, but also with chromogenic agar media. Although LTTC was found to be a very sensitive medium, the high degree of background growth of non-disinfected waters disturbed substantially the use of it. In conclusion, our results suggest that Colilert, CC and CECM are potential alternative media for detection of coliform bacteria and E. coli from non-disinfected water.

  14. Public Notification - Revised Total Coliform Rule Failure To Report Template

    EPA Pesticide Factsheets

    When a PWS fails to report their monitoring results for Total Coliform bacteria, it must issue a public notice to inform consumers of its water of that failure to report. This template can be used as a guide for preparing that public notice.

  15. Coliform Bacteria Monitoring in Fish Systems: Current Practices in Public Aquaria.

    PubMed

    Culpepper, Erin E; Clayton, Leigh A; Hadfield, Catherine A; Arnold, Jill E; Bourbon, Holly M

    2016-06-01

    Public aquaria evaluate coliform indicator bacteria levels in fish systems, but the purpose of testing, testing methods, and management responses are not standardized, unlike with the coliform bacteria testing for marine mammal enclosures required by the U.S. Department of Agriculture. An online survey was sent to selected aquaria to document current testing and management practices in fish systems without marine mammals. The information collected included indicator bacteria species, the size and type of systems monitored, the primary purpose of testing, sampling frequency, test methods, the criteria for interpreting results, corrective actions, and management changes to limit human exposure. Of the 25 institutions to which surveys were sent, 19 (76%) responded. Fourteen reported testing for fecal indicator bacteria in fish systems. The most commonly tested indicator species were total (86%) and fecal (79%) coliform bacteria, which were detected by means of the membrane filtration method (64%). Multiple types and sizes of systems were tested, and the guidelines for testing and corrective actions were highly variable. Only three institutions performed additional tests to confirm the identification of indicator organisms. The results from this study can be used to compare bacterial monitoring practices and protocols in fish systems, as an aid to discussions relating to the accuracy and reliability of test results, and to help implement appropriate management responses. Received August 23, 2015; accepted December 29, 2015.

  16. Fecal-coliform bacteria in extended-aeration plant sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, M.; Kester, G.; Arant, S.

    1998-07-01

    The concentration of fecal-coliform bacteria in sludge from extended-aeration plants was analyzed for compliance with new state and federal land application requirements. This study was initiated to determine if additional digestion would be necessary for plants to meet the new pathogen standards of less than 2 million CFU per gm of solids. Sludge was found to contain less than 2 million fecal coliform bacteria/gm of sludge as a result of a combination or aerobic digestion and/or long term storage.

  17. Patterns and sources of fecal coliform bacteria in three streams in Virginia, 1999-2000

    USGS Publications Warehouse

    Hyer, Kenneth; Moyer, Douglas

    2003-01-01

    Surface-water impairment by fecal coliform bacteria is a water-quality issue of national scope and importance. In Virginia, more than 175 stream segments are on the Commonwealth's 1998 303(d) list of impaired waters because of elevated concentrations of fecal coliform bacteria. These fecal coliform-impaired stream segments require the development of total maximum daily load (TMDL) and associated implementation plans, but accurate information on the sources contributing these bacteria usually is lacking. The development of defendable fecal coliform TMDLs and management plans can benefit from reliable information on the bacteria sources that are responsible for the impairment. Bacterial source tracking (BST) recently has emerged as a powerful tool for identifying the sources of fecal coliform bacteria that impair surface waters. In a demonstration of BST technology, three watersheds on Virginia's 1998 303(d) list with diverse land-use practices (and potentially diverse bacteria sources) were studied. Accotink Creek is dominated by urban land uses, Christians Creek by agricultural land uses, and Blacks Run is affected by both urban and agricultural land uses. During the 20-month field study (March 1999?October 2000), water samples were collected from each stream during a range of flow conditions and seasons. For each sample, specific conductance, dissolved oxygen concentration, pH, turbidity, flow, and water temperature were measured. Fecal coliform concentrations of each water sample were determined using the membrane filtration technique. Next, Escherichia coli (E. coli) were isolated from the fecal coliform bacteria and their sources were identified using ribotyping (a method of 'genetic fingerprinting'). Study results provide enhanced understanding of the concentrations and sources of fecal coliform bacteria in these three watersheds. Continuum sampling (sampling along the length of the streams) indicated that elevated concentrations of fecal coliform bacteria

  18. Coliform Bacteria for Bioremediation of Waste Hydrocarbons

    PubMed Central

    2017-01-01

    Raw, domestic sewage of Kuwait City contained about 106 ml−1 colony forming units of Enterobacter hormaechei subsp. oharae (56.6%), Klebsiella spp. (36%), and Escherichia coli (7.4%), as characterized by their 16S rRNA-gene sequences. The isolated coliforms grew successfully on a mineral medium with crude oil vapor as a sole source of carbon and energy. Those strains also grew, albeit to different degrees, on individual n-alkanes with carbon chains between C9 and C36 and on the individual aromatic hydrocarbons, toluene, naphthalene, phenanthrene, and biphenyl as sole sources of carbon and energy. These results imply that coliforms, like other hydrocarbonoclastic microorganisms, oxidize hydrocarbons to the corresponding alcohols and then to aldehydes and fatty acids which are biodegraded by β-oxidation to acetyl CoA. The latter is a well-known key intermediate in cell material and energy production. E. coli cells grown in the presence of n-hexadecane (but not in its absence) exhibited typical intracellular hydrocarbon inclusions, as revealed by transmission electron microscopy. Raw sewage samples amended with crude oil, n-hexadecane, or phenanthrene lost these hydrocarbons gradually with time. Meanwhile, the numbers of total and individual coliforms, particularly Enterobacter, increased. It was concluded that coliform bacteria in domestic sewage, probably in other environmental materials too, are effective hydrocarbon-biodegrading microorganisms. PMID:29082238

  19. Distribution of total and fecal coliform organisms from septic effluent in selected coastal plain soils.

    PubMed Central

    Reneau, R B; Pettry, D E; Shanholtz, M I; Graham, S A; Weston, C W

    1977-01-01

    Distribution of total and fecal coliform bacteria in three Atlantic coastal plain soils in Virginia were monitored in situ over a 3-year period. The soils studied were Varina, Goldsboro, and Beltsville sandy loams. These and similar soils are found extensively along the populous Atlantic seaboard of the United States. They are considered only marginally suitable for septic tank installation because the restricting soil layers result in the subsequent development of seasonal perched water tables. To determine both horizontal and vertical movement of indicator organisms, samples were collected from piezometers placed at selected distances and depths from the drainfields in the direction of the ground water flow. Large reductions in total and fecal coliform bacteria were noted in the perched ground waters above the restricting layers as distance from the drainfield increased. These restricting soil layers appear to be effective barriers to the vertical movement of indicator organisms. The reduction in the density of the coliform bacteria above the restricting soil layers can probably be attributed to dilution, filtration, and dieoff as the bacteria move through the natural soil systems. PMID:325589

  20. Comparison of m-Endo LES, MacConkey, and Teepol media for membrane filtration counting of total coliform bacteria in water.

    PubMed Central

    Grabow, W O; du Preez, M

    1979-01-01

    Total coliform counts obtained by means of standard membrane filtration techniques, using MacConkey agar, m-Endo LES agar, Teepol agar, and pads saturated with Teepol broth as growth media, were compared. Various combinations of these media were used in tests on 490 samples of river water and city wastewater after different stages of conventional purification and reclamation processes including lime treatment, and filtration, active carbon treatment, ozonation, and chlorination. Endo agar yielded the highest average counts for all these samples. Teepol agar generally had higher counts then Teepol broth, whereas MacConkey agar had the lowest average counts. Identification of 871 positive isolates showed that Aeromonas hydrophila was the species most commonly detected. Species of Escherichia, Citrobacter, Klebsiella, and Enterobacter represented 55% of isolates which conformed to the definition of total coliforms on Endo agar, 54% on Teepol agar, and 45% on MacConkey agar. Selection for species on the media differed considerably. Evaluation of these data and literature on alternative tests, including most probable number methods, indicated that the technique of choice for routine analysis of total coliform bacteria in drinking water is membrane filtration using m-Endo LES agar as growth medium without enrichment procedures or a cytochrome oxidase restriction. PMID:394678

  1. Multivariate logistic regression for predicting total culturable virus presence at the intake of a potable-water treatment plant: novel application of the atypical coliform/total coliform ratio.

    PubMed

    Black, L E; Brion, G M; Freitas, S J

    2007-06-01

    Predicting the presence of enteric viruses in surface waters is a complex modeling problem. Multiple water quality parameters that indicate the presence of human fecal material, the load of fecal material, and the amount of time fecal material has been in the environment are needed. This paper presents the results of a multiyear study of raw-water quality at the inlet of a potable-water plant that related 17 physical, chemical, and biological indices to the presence of enteric viruses as indicated by cytopathic changes in cell cultures. It was found that several simple, multivariate logistic regression models that could reliably identify observations of the presence or absence of total culturable virus could be fitted. The best models developed combined a fecal age indicator (the atypical coliform [AC]/total coliform [TC] ratio), the detectable presence of a human-associated sterol (epicoprostanol) to indicate the fecal source, and one of several fecal load indicators (the levels of Giardia species cysts, coliform bacteria, and coprostanol). The best fit to the data was found when the AC/TC ratio, the presence of epicoprostanol, and the density of fecal coliform bacteria were input into a simple, multivariate logistic regression equation, resulting in 84.5% and 78.6% accuracies for the identification of the presence and absence of total culturable virus, respectively. The AC/TC ratio was the most influential input variable in all of the models generated, but producing the best prediction required additional input related to the fecal source and the fecal load. The potential for replacing microbial indicators of fecal load with levels of coprostanol was proposed and evaluated by multivariate logistic regression modeling for the presence and absence of virus.

  2. Method of Detecting Coliform Bacteria and Escherichia Coli Bacteria from Reflected Light

    NASA Technical Reports Server (NTRS)

    Vincent, Robert (Inventor)

    2013-01-01

    The present invention relates to a method of detecting coliform bacteria in water from reflected light and a method of detecting Eschericha Coli bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  3. COMPOSITE SAMPLING FOR DETECTION OF COLIFORM BACTERIA IN WATER SUPPLY

    EPA Science Inventory

    Low densities of coliform bacteria introduced into distribution systems may survive in protected habitats. These organisms may interfere with and cause confusion in the use of the coliforms as indicators of sewage contamination of drinking water. Methods of increasing the probabi...

  4. Survival and detection of coliforms, Enterobacteriaceae, and gram-negative bacteria in Greek yogurt.

    PubMed

    Hervert, C J; Martin, N H; Boor, K J; Wiedmann, M

    2017-02-01

    Despite the widespread use of coliforms as indicator bacteria, increasing evidence suggests that the Enterobacteriaceae (EB) and total gram-negative groups more accurately reflect the hygienic status of high-temperature, short-time pasteurized milk and processing environments. If introduced into milk as postpasteurization contamination, these bacteria may grow to high levels and produce a wide range of sensory-related defects. However, limited information is available on the use and survival of bacterial hygiene indicators in dairy products outside of pasteurized fluid milk and cheese. The goal of this study was to (1) provide information on the survival of a diverse set of bacterial hygiene indicators in the low pH environment of Greek yogurt, (2) compare traditional and alternative detection methods for their ability to detect bacterial hygiene indicators in Greek yogurt, and (3) offer insight into optimal hygiene indicator groups for use in low-pH fermented dairy products. To this end, we screened 64 bacterial isolates, representing 24 dairy-relevant genera, for survival and detection in Greek yogurt using 5 testing methods. Before testing, isolates were inoculated into plain, 0% fat Greek yogurt (pH 4.35 to 4.65), followed by a 12-h hold period at 4 ± 1°C. Yogurts were subsequently tested using Coliform Petrifilm (3M, St. Paul, MN) to detect coliforms; Enterobacteriaceae Petrifilm (3M), violet red bile glucose agar and the D-Count (bioMérieux, Marcy-l'Étoile, France) to detect EB; and crystal violet tetrazolium agar (CVTA) to detect total gram-negative bacteria. Overall, the non-EB gram-negative isolates showed significantly larger log reductions 12 h after inoculation into Greek yogurt (based on bacterial numbers recovered on CVTA) compared with the coliform and noncoliform EB isolates tested. The methods evaluated varied in their ability to detect different microbial hygiene indicators in Greek yogurt. Crystal violet tetrazolium agar detected the highest

  5. Method of Detecting Coliform Bacteria from Reflected Light

    NASA Technical Reports Server (NTRS)

    Vincent, Robert K. (Inventor)

    2014-01-01

    The present invention relates to a method of detecting coliform bacteria in water from reflected light, and also includes devices for the measurement, calculation and transmission of data relating to that method.

  6. An Assessment of Coliform Bacteria in Water Sources Near Appalachian Trail Shelters Within the Great Smoky Mountains National Park.

    PubMed

    Reed, Brian C; Rasnake, Mark S

    2016-03-01

    Hikers and campers are exposed to risks while in the wilderness. One of these risks is the possibility of contracting an illness, including infectious diarrhea. This project tested for coliform bacteria in water samples taken near popular Appalachian Trail shelters. Water was collected from access points within the Great Smoky Mountains National Park. Samples were collected in sterile bottles and inoculated on a commercially available coliform detection kit for quantitative determination of total coliform and Escherichia coli counts. Water samples were taken during summer and fall seasons. During summer, 7 of 10 samples were positive for coliform bacteria and 6 of those 7 for E coli. The most probable number (MPN) of colony-forming units (CFU) for coliform bacteria ranged from 0 to 489 CFU/100 mL, with the MPN for E coli varying from 0 to 123 CFU/100 mL. These data differed from the fall collection, revealing 3 of 7 samples positive for coliform bacteria and 1 of those 3 for E coli. The MPN of CFU for coliform bacteria in fall samples varied from 0 to 119 CFU/100 mL and 0 to 5 to CFU/100 mL for E coli. Environmental Protection Agency drinking water standards set the standard of 0 CFU/100 mL to be considered safe. This analysis of water samples along the Appalachian Trail emphasizes that the majority of water access points require treatment during the summer season. Coliform burden was not as high through the fall months. These data suggest one infectious disease risk for wilderness travelers. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  7. Concentrations of fecal coliform bacteria in creeks, Anchorage, Alaska, August and September 1998

    USGS Publications Warehouse

    Dorava, Joseph M.; Love, Andra

    1999-01-01

    Water samples were collected from five creeks in undeveloped, semi-developed, and developed areas of Anchorage, Alaska, during August and September 1998 to determine concentrations of fecal coliform bacteria. In undeveloped areas of Ship, Chester, and Campbell Creeks, and the semi-developed area of Rabbit Creek, concentrations of fecal coliform bacteria ranged from less than 1 to 16 colonies per 100 milliliters of water. In the semi-developed area of Little Rabbit Creek, concentrations ranged from 30 to 860 colonies per 100 milliliters of water. In developed areas of the creeks, concentrations of fecal coliform bacteria ranged from 6 to 80 colonies per 100 milliliters of water.

  8. Comparison of methods for determining the numbers and species distribution of coliform bacteria in well water samples.

    PubMed

    Niemi, R M; Heikkilä, M P; Lahti, K; Kalso, S; Niemelä, S I

    2001-06-01

    Enumeration of coliform bacteria and Escherichia coli is the most widely used method in the estimation of hygienic quality of drinking water. The yield of target bacteria and the species composition of different populations of coliform bacteria may depend on the method.Three methods were compared. Three membrane filtration methods were used for the enumeration of coliform bacteria in shallow well waters. The yield of confirmed coliform bacteria was highest on Differential Coliform agar, followed by LES Endo agar. Differential Coliform agar had the highest proportion of typical colonies, of which 74% were confirmed as belonging to the Enterobacteriaceae. Of the typical colonies on Lactose Tergitol 7 TTC agar, 75% were confirmed as Enterobacteriaceae, whereas 92% of typical colonies on LES Endo agar belonged to the Enterobacteriaceae. LES Endo agar yielded many Serratia strains, Lactose Tergitol 7 TTC agar yielded numerous strains of Rahnella aquatilis and Enterobacter, whereas Differential Coliform agar yielded the widest range of species. The yield of coliform bacteria varied between methods. Each method compared had a characteristic species distribution of target bacteria and a typical level of interference of non-target bacteria. Identification with routine physiological tests to distinct species was hampered by the slight differences between species. High yield and sufficient selectivity are difficult to achieve simultaneously, especially if the target group is diverse. The results showed that several aspects of method performance should be considered, and that the target group must be distinctly defined to enable method comparisons.

  9. Total Coliform Rule (TCR) Federal Register Notice

    EPA Pesticide Factsheets

    This document provides the FR notice to 40 CFR Parts 141 and 142 Drinking Water: National Primary Drinking Water Regulations; Total Coliforms (Including Fecal Coliforms and E. Coli); Final Rule (26 pp, 5 M).

  10. Revised Total Coliform Rule Assessments and Corrective Actions

    EPA Pesticide Factsheets

    EPA has developed the Revised Total Coliform Rule Assessment and Corrective Actions Guidance Manual for public water systems (e.g., owners and operators) to assist in complying with the requirements of the Revised Total Coliform Rule.

  11. Inactivation of indigenous coliform bacteria in unfiltered surface water by ultraviolet light.

    PubMed

    Cantwell, Raymond E; Hofmann, Ron

    2008-05-01

    This study examined the potential for naturally occurring particles to protect indigenous coliform from ultraviolet (UV) disinfection in four surface waters. Tailing in the UV dose-response curve of the bacteria was observed in 3 of the 4 water samples after 1.3-2.6-log of log-linear inactivation, implying particle-related protection. The impact of particles was confirmed by comparing coliform UV inactivation data for parallel filtered (11 microm pore-size nylon filters) and unfiltered surface water. In samples from the Grand River (UVT: 65%/cm; 5.4 nephelometric turbidity units (NTU)) and the Rideau Canal (UVT: 60%/cm; 0.84 NTU), a limit of approximately 2.5 log inactivation was achieved in the unfiltered samples for a UV dose of 20 mJ/cm2 while both the filtered samples exhibited >3.4-log inactivation of indigenous coliform bacteria. The results suggest that particles as small as 11 microm, naturally found in surface water with low turbidity (<3NTU), are able to harbor indigenous coliform bacteria and offer protection from low-pressure UV light.

  12. Inactivation of Escherichia coli and coliform bacteria in traditional brass and earthernware water storage vessels.

    PubMed

    Tandon, Puja; Chhibber, Sanjay; Reed, Robert H

    2005-07-01

    The detection and enumeration of indicator bacteria such as Escherichia coli is used to assess the extent of faecal contamination of drinking water. On the basis of this approach, the effectiveness of storing water contaminated with faecal indicator bacteria in brass or earthern vessels (mutkas) of the type used in rural India have been investigated. Suspensions of bacteria in sterile distilled water were maintained for up to 48 h in each vessel and enumerated by surface plate counts on nutrient agar (non-selective) and several selective coliform media at 37 degrees C either under standard aerobic conditions, or under conditions designed to neutralise reactive oxygen species (ROS), e.g. using an anaerobic cabinet to prepare plates of pre-reduced growth medium or by inclusion of sodium pyruvate in the growth medium, with incubation of aerobically-prepared plates in an anaerobic jar. The counts obtained for E. coli decreased on short-term storage in a brass mutka; counts for selective media were lower than for equivalent counts for non-selective medium, with ROS-neutralised conditions giving consistently higher counts than aerobic incubation. However, after 48 h, no bacteria were cultivable under any conditions. Similar results were obtained using water from environmental sources in the Panjab, and from rural households where brass and earthern mutkas are used for storage of drinking water, with enumeration on selective coliform media (presumptive total coliforms). In all cases results indicated that, while storage of water in a brass mutka can inactivate E. coli and coliforms over a 48 h period, standard aerobic plate counting using selective media may not be fully effective in enumerating sub-lethally damaged bacteria.

  13. [The value of glucose-positive coliform bacteria and potentially pathogenic bacteria as indicators of epidemiological safety of tap water].

    PubMed

    Zhuravlev, P V; Aleshnia, V V; Panasovets, O P; Morozova, A A; Artemova, T Z; Talaeva, Iu G; Zagaĭnova, A V; Gipp, E K

    2012-01-01

    Due to intensive anthropogenic pollution of water environment generally accepted indicators of epidemic security of water bodies - common bacteria and thermotolerant coliform bacteria do not always permit to obtain an objective characterization of bacterial contamination of tap water. From the point of view of authors the integral index - glucose positive coliform bacteria most adequately reflect the sanitary-hygienic and epidemiological situation of water bodies. In monitoring for bacterial quality of tap water it is advisable to determine glucose positive coliform bacteria, that will provide the relevance of estimation of the epidemiological safety of water use. According to the method developed by the authors the calculation of the index of population risk of acute intestinal infections occurrence in dependence on the quality of tap water in Azov and Tsimlyansk towns.

  14. Modeling coliform-bacteria concentrations and pH in the salt-wedge reach of the Duwamish River Estuary, King County, Washington

    USGS Publications Warehouse

    Haushild, W.L.; Prych, Edmund A.

    1976-01-01

    Total- and fecal-coliform bacteria, plus pH, alkalinity, and dissolved inorganic carbon are water-quality parameters that have been added to an existing numerical model of water quality in the salt-wedge reach of the Duwamish River estuary in Washington. The coliform bacteria are modeled using a first-order decay (death) rate, which is a function of the local salinity, temperature, and daily solar radiation. The pH is computed by solving a set of chemical-equilibrium equations for carbonate-bicarbonate buffered aqueous solutions. Concentrations of total- and fecal-coliform bacteria computed by the model for the Duwamish River estuary during June-September 1971 generally agreed with observed concentrations within about 40 and 60 percent, respectively. The computed pH generally agreed with observed pH within about a 0.2 pH unit; however, for one 3-week period the computed pH was about a 0.4 unit lower than the observed pH. (Woodard-USGS)

  15. Coliform bacteria isolated from recreational lakes carry class 1 and class 2 integrons and virulence-associated genes.

    PubMed

    Koczura, R; Krysiak, N; Taraszewska, A; Mokracka, J

    2015-08-01

    To characterize the integron-harbouring Gram-negative bacteria in recreational lakes, with focus on the genetic content of integrons, antimicrobial resistance profiles and virulence-associated genes. The presence and structure of integrons in coliform bacteria isolated from the water of four recreational lakes located in Poznań, Poland, was determined by PCR method. Antimicrobial resistance testing was done by disc diffusion method. Virulence-associated genes in integron-bearing Escherichia coli isolates were detected by PCR. A total of 155 integron-bearing strains of coliform bacteria were cultured. Sequence analysis showed the presence of dfrA7, aadA1, dfrA1-aadA1, dfrA17-aadA5 and dfrA12-orfF-aadA2 gene cassette arrays in class 1 integrons and dfrA1-sat2-aadA1 in class 2 integrons. Higher frequency of integron-positive bacteria and higher antimicrobial resistance ranges were noted in colder months (January and November) compared with spring and summer months. The integron-harbouring E. coli carried up to nine virulence-associated genes, with the highest frequency of kpsMT (84.6%) and traT (783%), coding for group 2 capsule and determining human serum resistance respectively. Integron-bearing multidrug resistant coliform bacteria carrying virulence genes are present in waters of recreational lakes. This study presents antimicrobial resistance and virulence-associated genes in integron-bearing coliform bacteria present in the waters of recreational lakes, which showed that multidrug resistant bacteria with virulence traits might pose a threat to public health. Moreover, the presence of genes typical for enterotoxigenic and Shiga toxin-producing E. coli is a concern. © 2015 The Society for Applied Microbiology.

  16. Occurrence of fecal coliform bacteria in selected streams in Wyoming, 1990-99

    USGS Publications Warehouse

    Clark, Melanie L.; Norris, Jodi R.

    2000-01-01

    The U.S. Geological Survey (USGS), in cooperation with the Wyoming Department of Environmental Quality (WDEQ), is collecting water samples for analysis of fecal coliform bacteria at 18 stream sites as part of a statewide network. Contamination by bacteria of fecal origin in streams where contact recreation is a designated water use is a concern because of potential public-health risk from the presence of enteric pathogens. Fecal coliform concentrations are temporally and spatially variable in Wyoming streams-concentrations ranged from less than 1 to 45,000 colonies per 100 milliliters of water during 1990-99. Fecal coliform concentrations were less than the water-quality criterion of 400 colonies per 100 milliliters in 83 percent of the samples, indicating fecal coliform contamination is not a widespread problem in these Wyoming streams. However, 14 of the 18 monitoring sites had at least one sample in which the fecal coliform concentration exceeded 400 colonies per 100 milliliters at some time during the 10-year period. Fecal coliform concentrations generally are higher during April through September than during October through March. The higher concentrations coincide with the time period when the public-health risk is higher because summer months are when contact recreation use is more likely occurring. Fecal coliform concentrations were positively correlated with discharge and stream temperature and generally were negatively correlated with pH, specific conductance, and dissolved oxygen.

  17. The ultraviolet absorbance spectrum of coliform bacteria and its relationship to astronomy

    NASA Astrophysics Data System (ADS)

    Hoyle, F.; Wickramasinghe, N. C.; Jansz, E. R.; Jayatissa, P. M.

    1983-09-01

    The ultraviolet absorbance spectrum of a mixed culture of coliform bacteria is obtained and compared to recent measurements of the extinction curve of starlight. The absorbance of the bacterial suspensions over the wavebands 3500-2000 A and 7000-3400 A are presented along with a comparison of the extinction values for the star HD 14250 with the alpha function of the coliform suspension, which is a measure of the total amount of the material in the line of sight of the star. The agreement is excellent and is just as good as the agreement obtained by Karim et al. (1983) for typtophan in isolation, supporting the contention that the tryptophan responsible for the astronomical extinction is present in the interstellar grains in protein form.

  18. Enumeration and Identification of Coliform Bacteria Injured by Chlorine or Fungicide Mixed with Agricultural Water.

    PubMed

    Izumi, Hidemi; Nakata, Yuji; Inoue, Ayano

    2016-10-01

    Chemical sanitizers may induce no injury (bacteria survive), sublethal injury (bacteria are injured), or lethal injury (bacteria die). The proportion of coliform bacteria that were injured sublethally by chlorine and fungicide mixed with agricultural water (pond water), which was used to dilute the pesticide solution, was evaluated using the thin agar layer (TAL) method. In pure cultures of Enterobacter cloacae , Escherichia coli , and E. coli O157:H7 (representing a human pathogen), the percentage of chlorine-injured cells was 69 to 77% for dilute electrolyzed water containing an available chlorine level of 2 ppm. When agricultural water was mixed with electrolyzed water, the percentage of injured coliforms in agricultural water was 75%. The isolation and identification of bacteria on TAL and selective media suggested that the chlorine stress caused injury to Enterobacter kobei . Of the four fungicide products tested, diluted to their recommended concentrations, Topsin-M, Sumilex, and Oxirane caused injury to coliform bacteria in pure cultures and in agricultural water following their mixture with each pesticide, whereas Streptomycin did not induce any injury to the bacteria. The percentage of injury was 45 to 97% for Topsin-M, 80 to 87% for Sumilex, and 50 to 97% for Oxirane. A comparison of the coliforms isolated from the pesticide solutions and then grown on either TAL or selective media indicated the possibility of fungicide-injured Rahnella aquatilis , Yersinia mollaretii , and E. coli . These results suggest the importance of selecting a suitable sanitizer and the necessity of adjusting the sanitizer concentration to a level that will kill the coliforms rather than cause sanitizer-induced cell injury that can result in the recovery of the coliforms.

  19. [The significance of glucose positive coliform bacteria and potentially pathogenic bacteria as an indicator of epidemiological safety of tap water].

    PubMed

    Zhuravlev, P V; Aleshnya, V V; Panasovets, O P; Morozova, A A; Artemova, T Z; Talaeva, Yu G; Zagaynova, A V

    2013-01-01

    Due to intensive anthropogenic pollution of water environment generally accepted indicators of epidemic security of water bodies--common bacteria (CB) and thermotolerant coliform bacteria (TCB) do not always permit to obtain an objective characterization of bacterial contamination of tap water. From the point of view of authors the integral index--glucose positive coliform bacteria most adequately reflect the sanitary-hygienic and epidemiological situation of water bodies. In monitoring for bacterial quality of tap water it is advisable to determine glucose positive coliform bacteria, that will provide the relevance of estimation of the epidemiological safety of water use. According to the method developed by the authors the calculation of the index of population risk of acute intestinal infections (AHI) occurrence in dependence on the quality of tap water in Azov and Tsimlyansk towns.

  20. Occurrence of heterotrophic and coliform bacteria in liquid hand soaps from bulk refillable dispensers in public facilities.

    PubMed

    Chattman, Marisa; Gerba, Sheri L; Maxwell, Charles P

    2011-03-01

    The goal of the study discussed in this article was to determine the occurrence of heterotrophic and coliform bacteria in liquid soap from bulk refillable dispensers, obtained from restrooms in a variety of public facilities. A total of 541 samples was collected from five U.S. cities. Liquid soap from dispensers in public areas was found to contain heterotrophic and coliform bacterial numbers averaging more than 106 CFU/mL in 24.8% of the dispensers.

  1. Yeasts and coliform bacteria of water accumulated in bromeliads of mangrove and sand dune ecosystems of southeast Brazil.

    PubMed

    Hagler, A N; Rosa, C A; Morais, P B; Mendonça-Hagler, L C; Franco, G M; Araujo, F V; Soares, C A

    1993-10-01

    Yeasts and coliform bacteria were isolated from water that accumulated in the central cups and adjacent leaf axilae of two bromeliads, Neoregelia cruenta of a coastal sand dune and Quesnelia quesneliana of a mangrove ecosystem near the city of Rio de Janeiro, Brazil. The mean total coliform counts were above 10,000 per 100 mL for waters of both plants, but the mean fecal coliform counts were only 74 per 100 mL for Q. quesneliana and mostly undetected in water from N. cruenta. Of 90 fecal coliform isolates, 51 were typical of Escherichia coli in colony morphology and indol, methyl red, Volges-Proskauer, and citrate (IMViC) tests. Seven representatives of the typical E. coli cultures were identified as this species, but the identifications of nine other coliform bacteria were mostly dubious. The yeast community of N. cruenta was typical of plant surfaces with basidiomycetous yeasts anamorphs, and the black yeast Aureobasidium pullulans was prevalent. Quesnelia quesneliana had a substantial proportion of ascomycetous yeasts and their anamorphs, including a probable new biotype of Saccharomyces unisporus. Our results suggested that the microbial communities in bromeliad waters are typically autochtonous and not contaminants.

  2. Use of the Hydrological Simulation Program-FORTRAN and Bacterial Source Tracking for Development of the fecal coliform Total Maximum Daily Load (TMDL) for Accotink Creek, Fairfax County, Virginia

    USGS Publications Warehouse

    Moyer, Douglas; Hyer, Kenneth

    2003-01-01

    Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Accotink Creek, in Fairfax County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Accotink Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Accotink Creek. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Accotink Creek watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Accotink Creek. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Accotink Creek. The calibrated streamflow model simulated observed

  3. Faecal coliform bacteria in Febros river (northwest Portugal): temporal variation, correlation with water parameters, and species identification.

    PubMed

    Cabral, João Paulo; Marques, Cristina

    2006-07-01

    Febros river water was sampled weekly, during 35 successive weeks, and analyzed for microbiological (total coliforms, faecal coliforms, faecal streptococci and enterococci) and chemical-physical (ammonia and temperature) parameters. All microbiological parameters were highly correlated with each other and with ammonia, suggesting that the simultaneous determination of all variables currently in use in the evaluation of the microbiological quality of waters is probably redundant, and could be simplified, and that ammonia should be tested as a sentinel parameter of the microbiological pollution load of Febros river. From the strains isolated from positive tubes of the faecal coliforms test (multiple tube fermentation technique) and retested in this assay, Escherichia coli, Klebsiella oxytoca and Klebsiella pneumoniae subsp. pneumoniae strains were positive, indicating that the faecal coliforms test is not totally specific for Escherichia coli, and can detect other bacteria. Considering that these Klebsiella spp. are not necessarily of faecal origin, it was concluded that the faecal coliforms test can overestimate true faecal pollution. From the strains isolated from positive tubes of the faecal coliforms procedure, only Escherichia coli strains were clearly positive in the beta-D-glucuronidase test. All other species were negative or very weakly positive, suggesting that the assay of the beta-D-glucuronidase activity is less prone to false positives than the faecal coliforms test in the quantification of Escherichia coli in environmental waters.

  4. Identification and characterization of psychrotolerant coliform bacteria isolated from pasteurized fluid milk.

    PubMed

    Masiello, S N; Martin, N H; Trmčić, A; Wiedmann, M; Boor, K J

    2016-01-01

    The presence of coliform bacteria in pasteurized fluid milk typically indicates that product contamination occurred downstream of the pasteurizer, but it may also indicate pasteurization failure. Although coliform detection is frequently used as a hygiene indicator for dairy products, our understanding of the taxonomic and phenotypic coliform diversity associated with dairy products is surprisingly limited. Therefore, using Petrifilm Coliform Count plates (3M, St. Paul, MN), we isolated coliforms from high-temperature, short-time (HTST)-pasteurized fluid milk samples from 21 fluid milk processing plants in the northeast United States. Based on source information and initial characterization using partial 16S rDNA sequencing, 240 nonredundant isolates were obtained. The majority of these isolates were identified as belonging to the genera Enterobacter (42% of isolates), Hafnia (13%), Citrobacter (12%), Serratia (10%), and Raoultella (9%); additional isolates were classified into the genera Buttiauxella, Cedecea, Kluyvera, Leclercia, Pantoea, and Rahnella. A subset of 104 representative isolates was subsequently characterized phenotypically. Cold growth analysis in skim milk broth showed that all isolates displayed at least a 2-log increase over 10 d at 6°C; the majority of isolates (n=74) displayed more than a 5-log increase. In total, 43% of the representative isolates displayed lipolysis when incubated on spirit blue agar at 6°C for 14 d, whereas 71% of isolates displayed proteolysis when incubated on skim milk agar at 6°C for 14 d. Our data indicate that a considerable diversity of coliforms is found in HTST-pasteurized fluid milk and that a considerable proportion of these coliforms have phenotypic characteristics that will allow them to cause fluid milk spoilage. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Use of the Hydrological Simulation Program-FORTRAN and bacterial source tracking for development of the fecal coliform total maximum daily load (TMDL) for Christians Creek, Augusta County, Virginia

    USGS Publications Warehouse

    Moyer, Douglas; Hyer, Kenneth

    2003-01-01

    Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Christians Creek, in Augusta County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Christians Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Christians Creek. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Christians Creek watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Christians Creek. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Christians Creek. The calibrated streamflow model simulated

  6. Influence of enrichment broths on multiplex PCR detection of total coliform bacteria, Escherichia coli and Clostridium perfringens, in spiked water samples.

    PubMed

    Worakhunpiset, S; Tharnpoophasiam, P

    2009-07-01

    Although multiplex PCR amplification condition for simultaneous detection of total coliform bacteria, Escherichia coli and Clostridium perfringens in water sample has been developed, results with high sensitivity are obtained when amplifying purified DNA, but the sensitivity is low when applied to spiked water samples. An enrichment broth culture prior PCR analysis increases sensitivity of the test but the specific nature of enrichment broth can affect the PCR results. Three enrichment broths, lactose broth, reinforced clostridial medium and fluid thioglycollate broth, were compared for their influence on sensitivity and on time required with multiplex PCR assay. Fluid thioglycollate broth was the most effective with shortest enrichment time and lowest detection limit.

  7. Antimicrobial resistant coliform bacteria in the Gomti river water and determination of their tolerance level.

    PubMed

    Akhter, Asma; Imran, Mohd; Akhter, Firoz

    2014-01-01

    The distribution of resistance to ampicillin, chloramphenicol, sulfonamides, tetracycline, and streptomycin among coliform in the Gomti river water samples was investigated. The coliform populations were isolated on Mac Conky and eosin methylene blue (EMB) agar plates supplemented with antibiotics. The incidence of resistance among the coliform population varied considerably in different drug and water sampling sites. Coliform bacteria showed lower drug resistant viable count in sampling site-III (receiving treated wastewater) as compared to more polluted site-I and site-II. Viable count of coliform population obtained on both medium was recorded higher against erythromycin from sampling site-III. Lower viable count of coliforms was recorded against tetracycline in site-II and III. Similar resistance pattern was obtained in the frequency of E. coli and Enterobacter species from all the three sampling sites. Percentage of antibiotic resistant E. coli was observed higher than Enterobacter spp among the total coliforms against all antibiotics tested without Erythromycin and penicillin in site-I and II respectively. Isolates of E. coli and Enterobacter spp. showed their tolerance level (MIC) in the range of 2-100 against the antibiotics tested. Maximum number of isolates of both genus exhibited their MICs at lower concentration range 2-5µg/ml against ciprofloxacin, tetracyclin and amoxycillin. EMB - Eosin methylene blue, IMViC tests - Indole, Methyl Red, Voges Proskauer and Citrate Utilization Tests, MIC - Minimum inhibitory concentration.

  8. Antimicrobial resistant coliform bacteria in the Gomti river water and determination of their tolerance level

    PubMed Central

    Akhter, Asma; Imran, Mohd; Akhter, Firoz

    2014-01-01

    The distribution of resistance to ampicillin, chloramphenicol, sulfonamides, tetracycline, and streptomycin among coliform in the Gomti river water samples was investigated. The coliform populations were isolated on Mac Conky and eosin methylene blue (EMB) agar plates supplemented with antibiotics. The incidence of resistance among the coliform population varied considerably in different drug and water sampling sites. Coliform bacteria showed lower drug resistant viable count in sampling site-III (receiving treated wastewater) as compared to more polluted site-I and site-II. Viable count of coliform population obtained on both medium was recorded higher against erythromycin from sampling site-III. Lower viable count of coliforms was recorded against tetracycline in site-II and III. Similar resistance pattern was obtained in the frequency of E. coli and Enterobacter species from all the three sampling sites. Percentage of antibiotic resistant E. coli was observed higher than Enterobacter spp among the total coliforms against all antibiotics tested without Erythromycin and penicillin in site-I and II respectively. Isolates of E. coli and Enterobacter spp. showed their tolerance level (MIC) in the range of 2-100 against the antibiotics tested. Maximum number of isolates of both genus exhibited their MICs at lower concentration range 2-5µg/ml against ciprofloxacin, tetracyclin and amoxycillin. Abbreviations EMB - Eosin methylene blue, IMViC tests - Indole, Methyl Red, Voges Proskauer and Citrate Utilization Tests, MIC - Minimum inhibitory concentration. PMID:24966515

  9. Influence of Coliform Source on Evaluation of Membrane Filters

    PubMed Central

    Brodsky, M. H.; Schiemann, D. A.

    1975-01-01

    Four brands of membrane filters were examined for total and fecal coliform recovery performance by two experimental approaches. Using diluted EC broth cultures of water samples, Johns-Manville filters were superior to Sartorius filters for fecal coliform but equivalent for total coliform recovery. Using river water samples, Johns-Manville filters were superior to Sartorius filters for total coliform but equivalent for fecal coliform recovery. No differences were observed between Johns-Manville and Millipore or Millipore and Sartorius filters for total or fecal coliform recoveries using either approach, nor was any difference observed between Millipore and Gelman filters for fecal coliform recovery from river water samples. These results indicate that the source of the coliform bacteria has an important influence on the conclusions of membrane filter evaluation studies. PMID:1106318

  10. Use of the Hydrological Simulation Program-FORTRAN and bacterial source tracking for development of the fecal coliform total maximum daily load (TMDL) for Blacks Run, Rockingham County, Virginia

    USGS Publications Warehouse

    Moyer, Douglas; Hyer, Kenneth

    2003-01-01

    Impairment of surface waters by fecal coliform bacteria is a water-quality issue of national scope and importance. Section 303(d) of the Clean Water Act requires that each State identify surface waters that do not meet applicable water-quality standards. In Virginia, more than 175 stream segments are on the 1998 Section 303(d) list of impaired waters because of violations of the water-quality standard for fecal coliform bacteria. A total maximum daily load (TMDL) will need to be developed by 2006 for each of these impaired streams and rivers by the Virginia Departments of Environmental Quality and Conservation and Recreation. A TMDL is a quantitative representation of the maximum load of a given water-quality constituent, from all point and nonpoint sources, that a stream can assimilate without violating the designated water-quality standard. Blacks Run, in Rockingham County, Virginia, is one of the stream segments listed by the State of Virginia as impaired by fecal coliform bacteria. Watershed modeling and bacterial source tracking were used to develop the technical components of the fecal coliform bacteria TMDL for Accotink Creek. The Hydrological Simulation Program?FORTRAN (HSPF) was used to simulate streamflow, fecal coliform concentrations, and source-specific fecal coliform loading in Blacks Run. Ribotyping, a bacterial source tracking technique, was used to identify the dominant sources of fecal coliform bacteria in the Blacks Run watershed. Ribotyping also was used to determine the relative contributions of specific sources to the observed fecal coliform load in Blacks Run. Data from the ribotyping analysis were incorporated into the calibration of the fecal coliform model. Study results provide information regarding the calibration of the streamflow and fecal coliform bacteria models and also identify the reductions in fecal coliform loads required to meet the TMDL for Blacks Run. The calibrated streamflow model simulated observed streamflow

  11. COMPARISON OF ESCHERICHIA COLI, TOTAL COLIFORM, AND FECAL COLIFORM POPULATIONS AS INDICATORS OF WASTEWATER TREATMENT EFFICIENCY

    EPA Science Inventory

    Escherichia coli, total coliform, and fecal coliform data were collected from two wastewater treatment facilities, a subsurface constructed wetlands, and the receiving stream. Results are presented from individual wastewater treatment process streams, final effluent and river sit...

  12. An analysis of wilderness water in Kings Canyon, Sequoia, and Yosemite national parks for coliform and pathologic bacteria.

    PubMed

    Derlet, Robert W; Carlson, James R

    2004-01-01

    To determine the prevalence of coliform and potentially pathogenic bacteria in remote backcountry alpine lakes and streams of national parks in the Sierra Nevada mountains. Water was sampled at 55 predetermined lakes and streams that would stratify the risk, based on sites used by backpackers, sites used by pack animals, and uncontaminated wild areas. Sites were distributed among Kings Canyon (15), Sequoia (17), and Yosemite (23). Water was collected using Millipore bacterial samplers, which provided specific counts of coliform and other bacteria in each water sample and also served as a transport media from the wilderness to the laboratory. On return to the laboratory, bacteria were harvested from the samplers and subjected to specific identification and qualitative analysis using standard microbiology techniques for the analysis of water. Coliform bacteria were detected in 22 of the 55 sites. All of these sites were below areas used by backpackers or pack animals. Thirty-three sites were free of coliforms. These sites included both those used lightly by backpackers and those with no human or domestic animal use. All samples contained expected amounts of normal aquatic bacteria including Pseudomonas, Rahnella aquatilis, Serratia spp, and nonpathogenic species of Yersinia. Most sampling sites in these national parks are free of coliform or pathogenic organisms. Low levels of coliform bacteria are found in some bodies of water where the watershed has been affected by human or pack animal travel.

  13. Removal of fluoride, arsenic and coliform bacteria by modified homemade filter media from drinking water.

    PubMed

    Devi, Rani; Alemayehu, Esayas; Singh, Vijender; Kumar, Ashok; Mengistie, Embialle

    2008-05-01

    An attempt was made to investigate the removal of fluoride, arsenic and coliform bacteria from drinking water using modified homemade filter media. Batch mode experimental study was conducted to test the efficiency of modified homemade filter for reduction of impurities under the operating condition of treatment time. The physico-chemical and biological analysis of water samples had been done before and after the treatment with filter media, using standard methods. Optimum operating treatment time was determined for maximum removal of these impurities by running the experiment for 2, 4, 6, 8, 10 and 12h, respectively. The maximum reduction of fluoride, arsenic and coliform bacteria in percentage was 85.60%, 93.07% and 100% and their residual values were 0.72 mg/l, 0.009 mg/l and 0 coliform cells/100ml, respectively after a treatment time of 10h. These residual values were under the permissible limits prescribed by WHO. Hence this could be a cheap, easy and an efficient technique for removal of fluoride, arsenic and coliform bacteria from drinking water.

  14. Escherichia coli and fecal-coliform bacteria as indicators of recreational water quality

    USGS Publications Warehouse

    Francy, D.S.; Myers, Donna N.; Metzker, K.D.

    1993-01-01

    In 1986, the U.S. Environmental Protection Agency (USEPA) recommended that Escherichia coli (E. coli) be used in place of fecal-coliform bacteria in State recreational water-quality standards as an indicator of fecal contamination. This announcement followed an epidemiological study in which E. coli concentration was shown to be a better predictor of swimming-associated gastrointestinal illness than fecal-coliform concentration. Water-resource managers from Ohio have decided to collect information specific to their waters and decide whether to use E. coli or fecal-coliform bacteria as the basis for State recreational water-quality standards. If one indicator is a better predictor of recreational water quality than the other and if the relation between the two indicators is variable, then the indicator providing the most accurate measure of recreational water quality should be used in water-quality standards. Water-quality studies of the variability of concentrations of E. coli to fecal-coliform bacteria have shown that (1) concentrations of the two indicators are positively correlated, (2) E. coli to fecal-coliform ratios differ considerably from site to site, and (3) the E. coli criteria recommended by USEPA may be more difficult to meet than current (1992) fecal-coliform standards. In this study, a statistical analysis was done on concentrations of E. coli and fecal-coliform bacteria in water samples collected by two government agencies in Ohio-- the U.S. Geological Survey (USGS) and the Ohio River Valley Water Sanitation Commission (ORSANCO). Data were organized initially into five data sets for statistical analysis: (1) Cuyahoga River, (2) Olentangy River, (3) Scioto River, (4) Ohio River at Anderson Ferry, and (5) Ohio River at Cincinnati Water Works and Tanners Creek. The USGS collected the data in sets 1, 2, and 3, whereas ORSANCO collected the data in sets 4 and 5. The relation of E. coli to fecal-coliform concentration was investigated by use of linear

  15. Effects of levan-type fructan on growth performance, nutrient digestibility, diarrhoea scores, faecal shedding of total lactic acid bacteria and coliform bacteria, and faecal gas emission in weaning pigs.

    PubMed

    Lei, Xin Jian; Kim, Yong Min; Park, Jae Hong; Baek, Dong Heon; Nyachoti, Charles Martin; Kim, In Ho

    2018-03-01

    The use of antibiotics as growth promoters in feed has been fully or partially banned in several countries. The objective of this study was to evaluate effects of levan-type fructan on growth performance, nutrient digestibility, faecal shedding of lactic acid bacteria and coliform bacteria, diarrhoea scores, and faecal gas emission in weaning pigs. A total of 144 weaning pigs [(Yorkshire × Landrace) × Duroc] were randomly allocated to four diets: corn-soybean meal-based diets supplemented with 0, 0.1, 0.5, or 1.0 g kg -1 levan-type fructan during this 42-day experiment. During days 0 to 21 and 0 to 42, average daily gain and average daily feed intake were linearly increased (P < 0.01) with increasing dietary levan-type fructan inclusion. The apparent total tract digestibility of dry matter, crude protein, and gross energy were linearly increased (P < 0.001) with increasing dietary levan-type fructan content. With increasing levels of levan-type fructan, faecal lactic acid bacteria counts were linearly increased (P = 0.001). The results indicate that dietary supplementation with increasing levan-type fructan enhanced growth performance, improved nutrient digestibility, and increased faecal lactic acid bacteria counts in weaning pigs linearly. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  16. Modeling Fate and Transport of Fecal Coliform Bacteria Using SWAT 2005 (Case Study: Jajrood River Watershed, Iran)

    NASA Astrophysics Data System (ADS)

    Maghrebi, M.; Tajrishy, M.

    2010-12-01

    Jajrood River watershed is one of the main drinking water resources of the capital city of Tehran, Iran. In addition it has been available as many recreational usages especially in the warm months. As a result of being located near one of the crowded cities of the world, a variety of microbial pollutions is commonly perceived in the Jajrood River. Among them, there are strong concerns about fecal coliform bacteria concentration. This article aimed to model fate and transport of fecal coliform bacteria in Jajrood River watershed using Soil and Water Assessment Tool (SWAT) model version 2005. Potential pollutant sources in the study area were detected and quantified for modeling purposes. In spite of being lack of knowledge about bacteria die-off rate in small river bodies, as well as in other watershed-based forms, fecal coliform bacteria die-off rates were estimated using both laboratory and field data investigations with some simplifications. The SWAT model was calibrated over an extended time period (1997-2002) for this watershed. The river flow calibrated using SUFI-2 software and resulted in a very good outputs (R2=0.82, E=0.81). Furthermore SWAT model was validated over January 2003 to September 2005 in the study area and has resulted in good outputs (R2=0.61, E=0.57). This research illustrates SWAT 2005 capability to model fecal coliform bacteria in a populated watershed, and deals with most of watershed microbial pollution sources that are usually observed in developing countries. Fecal coliform concentration simulation results were mostly in the same order in comparison with real data. However, Differences were judged to be related to lack of input data. In this article different aspects of SWAT capabilities for modeling of fecal coliform bacteria concentration will be reviewed and it will present new insights in bacteria modeling procedures especially for mountainous, high populated and small sized watersheds.

  17. Revised Total Coliform Rule Lab Sampling Form

    EPA Pesticide Factsheets

    This form should be completed when a water system collects any required Revised Total Coliform Rule (RTCR) samples. It should also be used when collecting “Special” non-compliance samples for the RTCR.

  18. Revised Total Coliform Webinar for Primacy Agencies

    EPA Pesticide Factsheets

    This webinar was created to assist Primacy Agencies in the implementation of the Revised Total Coliform Rule. It provides an overview of the requirements in the rule and implementation guidance for Primacy Agencies.

  19. Molecular Method for Detection of Total Coliforms in Drinking Water Samples

    PubMed Central

    Boudreau, Dominique K.; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G.; Rodriguez, Manuel J.

    2014-01-01

    This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. PMID:24771030

  20. COMPARISON OF MEMBRANE FILTER, MULTIPLE-FERMENTATION-TUBE, AND PRESENCE-ABSENCE TECHNIQUES FOR DETECTING TOTAL COLIFORMS IN SMALL COMMUNITY WATER SYSTEMS

    EPA Science Inventory

    Methods for detecting total coliform bacteria in drinking water were compared using 1483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a ten tube fermentation tube tech...

  1. Effects of hot water application after defeathering on the levels of Campylobacter, coliform bacteria, and Escherichia coli on broiler carcasses.

    PubMed

    Berrang, M E; Dickens, J A; Musgrove, M T

    2000-11-01

    Scalding has been found to lower the levels of Campylobacter on broiler carcasses. However, the numbers recovered from whole-carcass rinse samples increase following defeathering. This study was undertaken to examine the effect of a second scald applied after defeathering on microbial levels recovered from carcass rinses. Four treatments were evaluated: 1) immersion at 60 C for 28 s 30 min after defeathering, 2) immersion at 60 C for 28 s immediately after defeathering, 3) spray at 73 C for 20 s 30 min after defeathering, and 4) spray at 71 C for 20 s immediately after defeathering. As reported earlier, a significant increase in Campylobacter counts per mL whole carcass rinse was noted after carcasses were defeathered. However, when applied 30 min after defeathering, neither the immersion nor the spray second scald treatments lowered the Campylobacter counts. Likewise, neither treatment had any affect on Escherichia coli or coliform bacteria counts, even though total counts were slightly reduced by the treatments. When the second scald treatment immediately followed defeathering, the same trends were observed. Campylobacter counts after the second scald remained at the postpick levels, as did counts for E. coli and coliform bacteria, but total plate counts were slightly reduced. Overall, it would appear that a postscald treatment gentle enough not to alter the carcass appearance or meat quality would not effectively lower Campylobacter, E. coli, or coliform bacteria counts.

  2. Full-scale studies of factors related to coliform regrowth in drinking water.

    PubMed

    LeChevallier, M W; Welch, N J; Smith, D B

    1996-07-01

    An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence

  3. Full-scale studies of factors related to coliform regrowth in drinking water.

    PubMed Central

    LeChevallier, M W; Welch, N J; Smith, D B

    1996-01-01

    An 18-month survey of 31 water systems in North America was conducted to determine the factors that contribute to the occurrence of coliform bacteria in drinking water. The survey included analysis of assimilable organic carbon (AOC), coliforms, disinfectant residuals, and operational parameters. Coliform bacteria were detected in 27.8% of the 2-week sampling periods and were associated with the following factors: filtration, temperature, disinfectant type and disinfectant level, AOC level, corrosion control, and operational characteristics. Four systems in the study that used unfiltered surface water accounted for 26.6% of the total number of bacterial samples collected but 64.3% (1,013 of 1,576) of the positive coliform samples. The occurrence of coliform bacteria was significantly higher when water temperatures were > 15 degrees C. For filtered systems that used free chlorine, 0.97% of 33,196 samples contained coliform bacteria, while 0.51% of 35,159 samples from chloraminated systems contained coliform bacteria. The average density of coliform bacteria was 35 times higher in free-chlorinated systems than in chloraminated water (0.60 CFU/100 ml for free-chlorinated water compared with 0.017 CFU/100 ml for chloraminated water). Systems that maintained dead-end free chlorine levels of < 0.2 mg/liter or monochloramine levels of < 0.5 mg/liter had substantially more coliform occurrences than systems that maintained higher disinfectant residuals. Free-chlorinated systems with AOC levels greater than 100 micrograms/liter had 82% more coliform-positive samples and 19 times higher coliform levels than free-chlorinated systems with average AOC levels less than 99 micrograms/liter. Systems that maintained a phosphate-based corrosion inhibitor and limited the amount of unlined cast iron pipe had fewer coliform bacteria. Several operational characteristics of the treatment process or the distribution system were also associated with increased rates of coliform occurrence

  4. Molecular method for detection of total coliforms in drinking water samples.

    PubMed

    Maheux, Andrée F; Boudreau, Dominique K; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G; Rodriguez, Manuel J

    2014-07-01

    This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  5. 75 FR 42440 - Total Coliform Rule Revisions-Notice of Public Information Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-21

    ... will be discussed include the cost and benefit information of the proposed rule and the planned... ENVIRONMENTAL PROTECTION AGENCY [FRL-9177-6] Total Coliform Rule Revisions--Notice of Public... Protection Agency (EPA) is hosting public information meetings on the proposed Revised Total Coliform Rule...

  6. Method for detecting coliform organisms

    NASA Technical Reports Server (NTRS)

    Nishioka, K.; Nibley, D. A.; Jeffers, E. L.; Brooks, R. L. (Inventor)

    1983-01-01

    A method and apparatus are disclosed for determining the concentration of coliform bacteria in a sample. The sample containing the coliform bacteria is cultured in a liquid growth medium. The cultured bacteria produce hydrogen and the hydrogen is vented to a second cell containing a buffer solution in which the hydrogen dissolves. By measuring the potential change in the buffer solution caused by the hydrogen, as a function of time, the initial concentration of bacteria in the sample is determined. Alternatively, the potential change in the buffer solution can be compared with the potential change in the liquid growth medium to verify that the potential change in the liquid growth medium is produced primarily by the hydrogen gas produced by the coliform bacteria.

  7. Comparison and continuous estimates of fecal coliform and Escherichia coli bacteria in selected Kansas streams, May 1999 through April 2002

    USGS Publications Warehouse

    Rasmussen, Patrick P.; Ziegler, Andrew C.

    2003-01-01

    The sanitary quality of water and its use as a public-water supply and for recreational activities, such as swimming, wading, boating, and fishing, can be evaluated on the basis of fecal coliform and Escherichia coli (E. coli) bacteria densities. This report describes the overall sanitary quality of surface water in selected Kansas streams, the relation between fecal coliform and E. coli, the relation between turbidity and bacteria densities, and how continuous bacteria estimates can be used to evaluate the water-quality conditions in selected Kansas streams. Samples for fecal coliform and E. coli were collected at 28 surface-water sites in Kansas. Of the 318 samples collected, 18 percent exceeded the current Kansas Department of Health and Environment (KDHE) secondary contact recreational, single-sample criterion for fecal coliform (2,000 colonies per 100 milliliters of water). Of the 219 samples collected during the recreation months (April 1 through October 31), 21 percent exceeded the current (2003) KDHE single-sample fecal coliform criterion for secondary contact rec-reation (2,000 colonies per 100 milliliters of water) and 36 percent exceeded the U.S. Environmental Protection Agency (USEPA) recommended single-sample primary contact recreational criterion for E. coli (576 colonies per 100 milliliters of water). Comparisons of fecal coliform and E. coli criteria indicated that more than one-half of the streams sampled could exceed USEPA recommended E. coli criteria more frequently than the current KDHE fecal coliform criteria. In addition, the ratios of E. coli to fecal coliform (EC/FC) were smallest for sites with slightly saline water (specific conductance greater than 1,000 microsiemens per centimeter at 25 degrees Celsius), indicating that E. coli may not be a good indicator of sanitary quality for those streams. Enterococci bacteria may provide a more accurate assessment of the potential for swimming-related illnesses in these streams. Ratios of EC/FC and

  8. Restoring water quality in the polluted Turag-Tongi-Balu river system, Dhaka: Modelling nutrient and total coliform intervention strategies.

    PubMed

    Whitehead, Paul; Bussi, Gianbattista; Hossain, Mohammed Abed; Dolk, Michaela; Das, Partho; Comber, Sean; Peters, Rebecca; Charles, Katrina J; Hope, Rob; Hossain, Md Sarwar

    2018-08-01

    River water quality in rapidly urbanising Asian cities threatens to damage the resource base on which human health, economic growth and poverty reduction all depend. Dhaka reflects the challenges and opportunities for balancing these dynamic and complex trade-offs which goals can be achieved through effective policy interventions. There is a serious problem of water pollution in central Dhaka, in the Turag-Tongi-Balu River system in Bangladesh with the river system being one of the most polluted in the world at the moment. A baseline survey of water chemistry and total coliforms has been undertaken and shows dissolved oxygen close to zero in the dry season, high organic loading together with extreme levels of Ammonium-N and total coliform in the water. Models have been applied to assess hydrochemical processes in the river and evaluate alternative strategies for policy and the management of the pollution issues. In particular models of flow, Nitrate-N, Ammonium-N and indicator bacteria (total coliforms) are applied to simulate water quality in the river system. Various scenarios are explored to clean up the river system, including flow augmentation and improved effluent treatment. The model results indicate that improved effluent treatment is likely to have a more significant impact on reducing Ammonium-N and total coliforms than flow augmentation, but a combined strategy would greatly reduce the pollution problems in the Turag-Tongi-Balu River System. Copyright © 2018. Published by Elsevier B.V.

  9. Molecular identification of coliform bacteria isolated from drinking water reservoirs with traditional methods and the Colilert-18 system.

    PubMed

    Kämpfer, Peter; Nienhüser, Anita; Packroff, Gabriele; Wernicke, Frank; Mehling, Arnd; Nixdorf, Katja; Fiedler, Stefanie; Kolauch, Claudia; Esser, Michael

    2008-07-01

    The accuracy of a traditional method (lactose utilization with acid and gas production) for the detection of coliform bacteria and E. coli was tested in comparison with method ISO 9308-1 (based on acid formation from lactose) and the Colilert-18 system (detection of beta-galactosidase). A total of 345 isolates were identified after isolation from water samples using API 20E strips. The Colilert-18 led to the highest number of positive findings (95% of the isolates were assigned to coliforms), whereas the ISO-9308-1 method resulted only in 29% coliform findings. With the traditional method only 15% were rated positive. Most of the isolates were identified by the API 20E system as Enterobacter spp. (species of the Enterobacter cloacae complex), Serratia spp., Citrobacter spp.and Klebsiella spp.; but species identification remained vague in several cases. A more detailed identification of 126 pure cultures by using 16S rRNA gene sequence analysis and analysis of the hsp60 gene resulted in the identification of Enterobacter nimipressuralis, E. amnigenus, E. asburiae, E. hormaechei, and Serratia fonticola as predominat coliforms. These species are beta-galactosidase positive, but show acid formation from lactose often after a prolonged incubation time. They are often not of fecal origin and may interfere with the ability to accurately detect coliforms of fecal origin.

  10. Effect of Tetracycline Dose and Treatment Mode on Selection of Resistant Coliform Bacteria in Nursery Pigs

    PubMed Central

    Græsbøll, Kaare; Damborg, Peter; Mellerup, Anders; Herrero-Fresno, Ana; Larsen, Inge; Holm, Anders; Nielsen, Jens Peter; Christiansen, Lasse Engbo; Angen, Øystein; Ahmed, Shahana

    2017-01-01

    ABSTRACT This study describes the results of a randomized clinical trial investigating the effect of oxytetracycline treatment dose and mode of administration on the selection of antibiotic-resistant coliform bacteria in fecal samples from nursery pigs. Nursery pigs (pigs of 4 to 7 weeks of age) in five pig herds were treated with oxytetracycline for Lawsonia intracellularis-induced diarrhea. Each group was randomly allocated to one of five treatment groups: oral flock treatment with a (i) high (20 mg/kg of body weight), (ii) medium (10 mg/kg), or (iii) low (5 mg/kg) dose, (iv) oral pen-wise (small-group) treatment (10 mg/kg), and (v) individual intramuscular injection treatment (10 mg/kg). All groups were treated once a day for 5 days. In all groups, treatment caused a rise in the numbers and proportions of tetracycline-resistant coliform bacteria right after treatment, followed by a significant drop by the time that the pigs left the nursery unit. The counts and proportions of tetracycline-resistant coliforms did not vary significantly between treatment groups, except immediately after treatment, when the highest treatment dose resulted in the highest number of resistant coliforms. A control group treated with tiamulin did not show significant changes in the numbers or proportions of tetracycline-resistant coliforms. Selection for tetracycline-resistant coliforms was significantly correlated to selection for ampicillin- and sulfonamide-resistant strains but not to selection for cefotaxime-resistant strains. In conclusion, the difference in the dose of oxytetracycline and the way in which the drug was applied did not cause significantly different levels of selection of tetracycline-resistant coliform bacteria under the conditions tested. IMPORTANCE Antimicrobial resistance is a global threat to human health. Treatment of livestock with antimicrobials has a direct impact on this problem, and there is a need to improve the ways that we use antimicrobials in

  11. Effect of Tetracycline Dose and Treatment Mode on Selection of Resistant Coliform Bacteria in Nursery Pigs.

    PubMed

    Græsbøll, Kaare; Damborg, Peter; Mellerup, Anders; Herrero-Fresno, Ana; Larsen, Inge; Holm, Anders; Nielsen, Jens Peter; Christiansen, Lasse Engbo; Angen, Øystein; Ahmed, Shahana; Folkesson, Anders; Olsen, John Elmerdahl

    2017-06-15

    This study describes the results of a randomized clinical trial investigating the effect of oxytetracycline treatment dose and mode of administration on the selection of antibiotic-resistant coliform bacteria in fecal samples from nursery pigs. Nursery pigs (pigs of 4 to 7 weeks of age) in five pig herds were treated with oxytetracycline for Lawsonia intracellularis -induced diarrhea. Each group was randomly allocated to one of five treatment groups: oral flock treatment with a (i) high (20 mg/kg of body weight), (ii) medium (10 mg/kg), or (iii) low (5 mg/kg) dose, (iv) oral pen-wise (small-group) treatment (10 mg/kg), and (v) individual intramuscular injection treatment (10 mg/kg). All groups were treated once a day for 5 days. In all groups, treatment caused a rise in the numbers and proportions of tetracycline-resistant coliform bacteria right after treatment, followed by a significant drop by the time that the pigs left the nursery unit. The counts and proportions of tetracycline-resistant coliforms did not vary significantly between treatment groups, except immediately after treatment, when the highest treatment dose resulted in the highest number of resistant coliforms. A control group treated with tiamulin did not show significant changes in the numbers or proportions of tetracycline-resistant coliforms. Selection for tetracycline-resistant coliforms was significantly correlated to selection for ampicillin- and sulfonamide-resistant strains but not to selection for cefotaxime-resistant strains. In conclusion, the difference in the dose of oxytetracycline and the way in which the drug was applied did not cause significantly different levels of selection of tetracycline-resistant coliform bacteria under the conditions tested. IMPORTANCE Antimicrobial resistance is a global threat to human health. Treatment of livestock with antimicrobials has a direct impact on this problem, and there is a need to improve the ways that we use antimicrobials in livestock

  12. Coliform bacteria removal from sewage in constructed wetlands planted with Mentha aquatica.

    PubMed

    Avelar, Fabiana F; de Matos, Antonio T; de Matos, Mateus P; Borges, Alisson C

    2014-08-01

    The present study evaluated the performance of the species Mentha aquatica in constructed wetlands of horizontal subsurface flow (CW-HSSF) with regard to the removal of coliforms bacteria in an effluent from the primary treatment of sewage as well as to obtain adjustment parameters of the bacterial decay kinetic model along the length of the CW-HSSF. Therefore, four CW-HSSFs measuring 24.0 m x 1.0 m x 0.35 m were built and filled with number 0 gravel as the support medium to a height of 0.20m. Two of the CW-HSSFs were planted with the species M. aquatica, while the other two remained uncultivated. Cultivation of M. aquatica in CW-HSSF resulted in total coliforms (TC) and Escherichia coli (EC) removals from 0.9 to 1.3 log units greater than those obtained in the uncultivated experimental plots, for the hydraulic retention times (HRTs) of 4.5 and 6.0 days. For HRT ranged from 1.5 to 6.0 days, the highest removal efficiencies in counts of TC and EC were obtained when using longer HRT. The mathematical models evaluated showed good fit to average counts of TC and EC highlighting the modified first-order kinetic model with the inclusion of the power parameter in the HRT variable.

  13. Environmental factors influencing the distribution of total and fecal coliform bacteria in six water storage reservoirs in the Pearl River Delta Region, China.

    PubMed

    Hong, Huachang; Qiu, Jianwen; Liang, Yan

    2010-01-01

    The Pearl River Delta (PRD) is one of the most developed and densely populated regions in China. Quantifying the amount of pathogens in the source of drinking water is important for improving water quality. We collected water samples from six major water storage reservoirs in the PRD region in both wet and dry seasons in 2006. Results showed that external environmental factors, such as precipitation, location, as well as the internal environmental factors, i.e., physicochemical properties of the water, were closely related with the distribution of coliforms. Seasonally, the coliform bacterial concentrations in wet season were one to two orders of magnitude greater than those in dry season. Spatially, coliform bacterial levels in reservoirs near urban and industrial areas were significantly higher (p < 0.05) than those in remote areas. Correlation analyses showed that the levels of coliforms had close relationships with pH, temperature, suspended solid, organic and inorganic nutrients in water. Principal components analysis further demonstrated that total coliforms in the reservoirs were closely related with water physicochemical properties, while fecal coliforms were more associated with external input brought in by seasonal runoff.

  14. Removal of native coliphages and coliform bacteria from municipal wastewater by various wastewater treatment processes: implications to water reuse.

    PubMed

    Zhang, K; Farahbakhsh, K

    2007-06-01

    The efficacy of a conventional activated sludge wastewater treatment process and the membrane bioreactor technology in removing microbial pathogens was investigated. Total and fecal coliforms and somatic and F-specific coliphages were used as indicators of pathogenic bacteria and viruses. Up to 5.7 logs removal of coliforms and 5.5 logs of coliphages were observed in the conventional treatment process with advanced tertiary treatment. Addition of chemical coagulants seemed to improve the efficacy of primary and secondary treatment for microorganism removal. Complete removal of fecal coliforms and up to 5.8 logs removal of coliphages was observed in the MBR system. It was shown that the MBR system was capable of high removal of coliphages despite the variation in feed coliphage concentrations. The results of this study indicated that the MBR system can achieve better microbial removal in far fewer steps than the conventional activated sludge process with advanced tertiary treatment. The final effluent from either treatment processes can be potentially reused.

  15. The presence-absence coliform test for monitoring drinking water quality.

    PubMed Central

    Rice, E W; Geldreich, E E; Read, E J

    1989-01-01

    The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663

  16. Removal of total coliform and E. coli using zeliac as filter media

    NASA Astrophysics Data System (ADS)

    Ibrahim, Nurazim; Aziz, Hamidi Abdul; Yusoff, Mohd Suffian

    2017-10-01

    High loading of wastewater and surface run off into river contributed to large amount of microorganisms entering drinking water sources. The aim of this study was to investigate the capability of composite adsorbent namely Zeliac to remove total coliform and E. coli from river water using fixed bed column experiment. Two ranges of Zeliac particle sizes (1.18- 2 mm and 0.425- 0.6 mm) were applied to observe the effect of particle size on the removal of the selected pollutants. Kerian River water with a total coliform and E. coli concentration of 14, 082 ± 4, 209 and 208 ± 166 MPN/100 mL respectively was continuously supplied to the column at constant flow rate of 20 (Column A) and 21 ml/min (Column B) for 991 hours. The presence of total coliform and E. coli in the treated water were detected using Colilert test kit from IDEXX Corporation. The performance of Zeliac as filter media was analysed by a breakthrough curve plotted from normalized concentration (C/Co) against time. It was discovered that a difference in particle size does not give a significant impact to the removal of total coliform and E. coli in this system. According to the plotted breakthrough curves, Zeliac as filter media was capable to immobilize total coliform and E. coli for up to 31 hours of contact time. This finding shows that Zeliac has the potential to retain pathogenic microorganism such as E. coli in a continuous fluid flow.

  17. The capacity of the Gunderboom in Mamaroneck Harbor on the reduction of E. coli and coliform bacteria from water and soft-shelled clams (Mya arenaria).

    PubMed

    Yeung-Cheung, Anna K; Melendez, Nadilynn J

    2007-02-01

    Harbor Island Park of Mamaroneck Harbor is one of the beaches that has been frequently closed to the public due to unsanitary swimming conditions. In 2002, a Gunderboom BPS (Beach Protection System) was reinstalled in Harbor Island Park to lower bacterial levels in swimming areas. The first Gunderboom had been destroyed by an oil spill several years before. The current Gunderboom is an 800 foot curtain made of a treated polypropylene/polyester fabric and the company claims a 99.1% coliform reduction with its use. In this study, water inside and outside the Gunderboom was tested weekly from June to August 2005, and bi-weekly from September to December 2005. Coliscan Membrane Filtration plates were used to recover the relative amounts of Escherichia coli and coliform bacteria from the water. Soft-shelled clams (Mya arenaria) living in both these areas were also tested for their E. coli and coliform bacteria level using 3M Petrifilm plates. Water was also tested from Hudson Park in New Rochelle, a frequently closed beach due to high levels of coliform bacteria, as well as from Read Sanctuary in Rye, a "pristine" beach. Our results showed the amount of E. coli and coliform bacteria recovered from the water inside the Gunderboom were significantly lower (P < 0.05) compared to outside the Gunderboom and Hudson Park. There was 81.9% reduction in E. coli and 51.6% reduction in coliform bacteria inside the Gunderboom as compared to the outside. In addition, significant differences (P < 0.05) were found with lower numbers of E. coli and coliform bacteria recovered from the clams inside the Gunderboom compared to outside the Gunderboom. In conclusion, the Gunderboom system installed in Mamaroneck Harbor resulted in a significant reduction of E. coli and coliform bacteria in the water and clam samples, thus proving its efficiency as a water filter.

  18. Total Coliform Rule Distribution System Advisory Committee (TCRDSAC) Document

    EPA Pesticide Factsheets

    This document provide information about the TCRDSAC, including its charter, processes and recommendations. The Agency used the Advisory Committee recommendations to develop proposed and final rules that revised the Total Coliform Rule.

  19. Tracing the contamination origin of coliform bacteria in two small food-processing factories.

    PubMed

    Tominaga, Tatsuya; Sekine, Masahiro; Oyaizu, Hiroshi

    2008-09-01

    The objective of this study was to trace contamination sources of coliform bacteria by comparing the types of coliforms between food samples and the processing environments in two small food-processing factories (factories A and B). Fermentation tests of five sugars enabled the successful classification of 16 representative type strains into eight distinct groups. The grouping procedure was then applied to comparison of the coliform flora between food products and various locations in their processing environments. The consistency between each food and the tested locations was evaluated using the Jaccard index. The air conditioner and refrigeration room floor in factory A showed an index of 1.00, while the shaping machine in factory B showed an index of 0.98, indicating that these locations could be contamination sources. The validity of our results was confirmed by randomly amplified polymorphic DNA, which showed 100% matched profiles between the air conditioner and the food in factory A, and highly matched profiles between the machine and the food in factory B. This method for comparing the coliform flora between food and environments has the potential to be a reliable tracing tool for various food industries.

  20. ESCHERICHIA COLI AND TOTAL COLIFORMS IN WATER AND SEDIMENTS AT LAKE MARINAS

    EPA Science Inventory

    Escherichia coli, a fecal coliform, and total coliforms were monitored between September 1999 to October 2001 in five marinas on Lake Texoma, located on the Oklahoma and Texas border. General trend was that densities of E. coli were lower in the summer season due to the lower ...

  1. [Comparative assessment of sanitary and epidemic importance of indicator coliform indices of drinking water quality].

    PubMed

    Rakhmanin, Yu A; Ivanova, L V; Artemova, T Z; Gipp, E K; Zagaynova, A V; Maksimkina, T N; Krasnyak, A V; Zhuravlev, P V; Aleshnya, V V; Panasovets, O P

    2016-01-01

    The used methodology of the scientific substantiation of indicators is in the establishment of the conformity of laws of vital activity of indicator and pathogenic microorganisms in the real conditions of the action of the complex of factors, including disinfecting agents. In the one water sample simultaneously there were determined both the general indicator (GICB), thermotolerant (TTCB), glucose positive (GPCB) coliform bacteria, E.coli. On the base of long-term research in the various regions of the Russian Federation, as well with bearing in mind the analysis of domestic and foreign data, comparing the water quality and the incidence of intestinal infections in population it is recommended to use the index of determination of the total number glucose positive coliform bacteria (GPCB), which brings together a much broader range of bacteria of the Enterobacteriaceae family in comparison with total coliform bacteria (TCB) and thermotolerant coliform bacteria (TTCB) and warrants the absence in the test volume of water as an indicator lactose positive (E.coli, TCB, TTCB) and pathogens (salmonella) and potentially pathogenic bacteria which do not ferment lactose. Proposed index of GPCB is shown to allow to assess epidemiological risks not only more accurate, but also more efficiently without increasing the cost performance of bacteriological research.

  2. Coliform Contamination of Peri-urban Grown Vegetables and Potential Public Health Risks: Evidence from Kumasi, Ghana.

    PubMed

    Abass, Kabila; Ganle, John Kuumuori; Adaborna, Eric

    2016-04-01

    Peri-urban vegetable farming in Ghana is an important livelihood activity for an increasing number of people. However, increasing quality and public health concerns have been raised, partly because freshwater availability for irrigation purposes is a major constraint. This paper investigated on-farm vegetable contamination and potential health risks using samples of lettuce, spring onions and cabbage randomly selected from 18 vegetable farms in peri-urban Kumasi, Ghana. Vegetable samples were tested for total coliform, fecal coliform, Escherichia coli and Salmonella spp. bacteria contamination using the Most Probable Number method. Results show high contamination levels of total and fecal coliforms, and Escherichia coli bacteria in all 18 vegetable samples. The mean total coliform/100 ml concentration for spring onions, lettuce and cabbage were 9.15 × 10(9), 4.7 × 10(7) and 8.3 × 10(7) respectively. The mean fecal coliform concentration for spring onions, lettuce and cabbage were also 1.5 × 10(8), 4.15 × 10(7) and 2.15 × 10(7) respectively, while the mean Escherichia coli bacteria contamination for spring onions, lettuce and cabbage were 1.4 × 10(8), 2.2 × 10(7) and 3.2 × 10(7) respectively. The level of total coliform, fecal coliform and Escherichia coli bacteria contamination in all the vegetable samples however declined as the distance between the main water source (Wiwi River) and farms increases. Nonetheless, all contamination levels were well above acceptable standards, and could therefore pose serious public health risks to consumers. Increased education and supervision of farmers, as well as public health and food hygiene education of consumers, are critical to reducing on-farm vegetable contamination and the health risks associated with consumption of such vegetables.

  3. Effect of wastewater quality parameters on coliform inactivation by tin oxide anodes.

    PubMed

    Teel, Amy L; Watts, Richard J

    2018-04-16

    The effect of six water quality constituents on wastewater effluent disinfection by tin oxide anodes (TOAs) was investigated in single cell laboratory reactors. Several concentrations of suspended solids, chemical oxygen demand (COD), alkalinity, ammonia-nitrogen, nitrite-nitrogen, and nitrate-nitrogen were added to media containing 10 6 total coliform bacteria mL -1 . Current was applied through the TOAs, and coliform bacteria viability was analyzed over time. Over 99.9% inactivation of coliform bacteria was found over 15 min in TOA reactors. Concentrations of the six water quality constituents typical of concentrations found in wastewaters had no effect on TOA disinfection efficacy. The results of this research demonstrate that TOAs, which could potentially be powered by solar panels, have potential as a sustainable disinfection process compared to chlorine, ozone, and ultraviolet light.

  4. Evaluation of media for simultaneous enumeration of total coliform and Escherichia coli in drinking water supplies by membrane filtration techniques.

    PubMed

    Wang, Dunling; Fiessel, Wanda

    2008-01-01

    This study evaluated three different dehydrated media for simultaneous detection and enumeration of total coliform (TC) and Escherichia coli in drinking water samples with a standard membrane filtration procedure. The experiment indicated that the differential coliform agar (DCA) medium was the most effective among the tested media in enumerating TC and E. coli, without the need for extensive accompanying confirmation tests. The results for DCA medium were highly reproducible for both TC and E. coli with standard deviation of 6.0 and 6.1, respectively. A high agreement (82%) was found between DCA and m-Endo media on 152 drinking water samples in terms of TC positive. The DCA medium also reduced concealment of background bacteria.

  5. Coliform Bacteria and Nitrogen Fixation in Pulp and Paper Mill Effluent Treatment Systems

    PubMed Central

    Gauthier, Francis; Neufeld, Josh D.; Driscoll, Brian T.; Archibald, Frederick S.

    2000-01-01

    The majority of pulp and paper mills now biotreat their combined effluents using activated sludge. On the assumption that their wood-based effluents have negligible fixed N, and that activated-sludge microorganisms will not fix significant N, these mills routinely spend large amounts adding ammonia or urea to their aeration tanks (bioreactors) to permit normal biomass growth. N2 fixation in seven Eastern Canadian pulp and paper mill effluent treatment systems was analyzed using acetylene reduction assays, quantitative nitrogenase (nifH) gene probing, and bacterial isolations. In situ N2 fixation was undetectable in all seven bioreactors but was present in six associated primary clarifiers. One primary clarifier was studied in greater detail. Approximately 50% of all culturable cells in the clarifier contained nifH, of which >90% were Klebsiella strains. All primary-clarifier coliform bacteria growing on MacConkey agar were identified as klebsiellas, and all those probed contained nifH. In contrast, analysis of 48 random coliform isolates from other mill water system locations showed that only 24 (50%) possessed the nifH gene, and only 13 (27%) showed inducible N2-fixing activity. Thus, all the pulp and paper mill primary clarifiers tested appeared to be sites of active N2 fixation (0.87 to 4.90 mg of N liter−1 day−1) and a microbial community strongly biased toward this activity. This may also explain why coliform bacteria, especially klebsiellas, are indigenous in pulp and paper mill water systems. PMID:11097883

  6. 40 CFR 142.63 - Variances and exemptions from the maximum contaminant level for total coliforms.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) EPA has stayed the effective date of this section relating to the total coliform MCL of § 141.63(a) of this chapter for systems that demonstrate to the State that the violation of the total coliform MCL is...

  7. Viability of sublethally injured coliform bacteria on fresh-cut cabbage stored in high CO2 atmospheres following rinsing with electrolyzed water.

    PubMed

    Izumi, Hidemi; Inoue, Ayano

    2018-02-02

    The extent of sublethally injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, was evaluated during storage in air and high CO 2 controlled atmospheres (5%, 10%, and 15%) at 5°C and 10°C using the thin agar layer (TAL) method. Sublethally injured coliform bacteria on nonrinsed shredded cabbage were either absent or they were injured at a 64-65% level when present. Rinsing of shredded cabbage with electrolyzed water containing 25ppm available chlorine reduced the coliform counts by 0.4 to 1.1 log and caused sublethal injury ranging from 42 to 77%. Pantoea ananatis was one of the species injured by chlorine stress. When shredded cabbage, nonrinsed or rinsed with electrolyzed water, was stored in air and high CO 2 atmospheres at 5°C for 7days and 10°C for 5days, coliform counts on TAL plates increased from 3.3-4.5 to 6.5-9.0 log CFU/g during storage, with the increase being greater at 10°C than at 5°C. High CO 2 of 10% and 15% reduced the bacterial growth on shredded cabbage during storage at 5°C. Although injured coliform bacteria were not found on nonrinsed shredded cabbage on the initial day, injured coliforms at a range of 49-84% were detected on samples stored in air and high CO 2 atmospheres at 5°C and 10°C. Injured cells were detected more frequently during storage at both temperatures irrespective of the CO 2 atmosphere when shredded cabbage was rinsed with electrolyzed water. These results indicated that injured coliform bacteria on shredded cabbage, either rinsed or not rinsed with electrolyzed water, exhibited different degrees of injury during storage regardless of the CO 2 atmosphere and temperature tested. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. 75 FR 49930 - Stakeholder Meeting Regarding Re-Evaluation of Currently Approved Total Coliform Analytical Methods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-16

    ... Currently Approved Total Coliform Analytical Methods AGENCY: Environmental Protection Agency (EPA). ACTION... of currently approved Total Coliform Rule (TCR) analytical methods. At these meetings, stakeholders will be given an opportunity to discuss potential elements of a method re-evaluation study, such as...

  9. Total Coliform Determinations. Training Module 5.205.3.77.

    ERIC Educational Resources Information Center

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining total coliform concentration of a water supply. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…

  10. Photocatalytic degradation of E. coliform in water.

    PubMed

    Sun, Darren Delai; Tay, Joo Hwa; Tan, Koh Min

    2003-08-01

    This study aims to further investigate the total mineralization of the bacteria to the extent of death and cell-mass inactivation using a TiO2-Fe2O3 membrane photocatalytic oxidation reactor. Experimental results clearly indicated that dissolved oxygen (DO), hydraulic retention time (HRT) and concentration of the model bacteria (Escherichia coliform) affected the removal efficiency. It was found that the ultimate removal efficiency was 99% at DO level of 21.34 mg/l, HRT at 60s and high concentration of E. coli at 10(9)CFU/ml. The morphologic studies also showed that E. coliform could be further mineralized into CO2 and H2O. Dissolved organic carbon, pH and gas chromatograph analysis had justified most importantly the evolution of CO2. Experimental results revealed that the photomineralization rate of E. coliform followed pseudo-first-order kinetics by the role of DO. The derived empirical models were found consistent with the proposed reaction pathways of a combined UV breakdown on mass cell and a dual-site Langmuir-Hinshelwood mechanism where the rate-controlling step is the surface interaction between the adsorbed cleavage bacterial cells and hydroxyl radicals.

  11. Coliform inhibition by bacteriocin-like substances in drinking water distribution systems.

    PubMed Central

    Means, E G; Olson, B H

    1981-01-01

    Bacterial isolates from an unchlorinated potable groundwater system and a chlorinated surface water system were screened by an agar overlay method for the ability to produce bacteriocin-like substances (BLS) inhibitory to the growth of Escherichia coli, Klebsiella sp., and Enterobacter aerogenes. The production of coliform-specific BLS by noncoliform bacteria varied with the site and date of isolation as well as the genus of the producer strain. A total of 448 bacterial isolates were screened from the chlorinated system, and 22.1% produced BLS specific for at least one of the three coliforms. In the unchlorinated system, 7.9% (n = 696) possessed this ability. Flavobacterium/Moraxella comprised 57.1% of all bacteria (from both systems) producing BLS. The possibility that BLS interfere with coliform detection in standard bacteriological water quality tests is discussed. Images PMID:7027953

  12. Fluorogenic membrane overlays to enumerate total coliforms, Escherichia coli, and total Vibrionaceae in shellfish and seawater

    USDA-ARS?s Scientific Manuscript database

    Three assays were developed to enumerate total coliforms, Escherichia coli, and total Vibrionaceae in shellfish and other foods and in seawater and other environmental samples. Assays involve membrane overlays of overnight colonies on non-selective agar plates to detect ß-glucuronidase and lysyl am...

  13. Comparison of Clark's presence-absence test and the membrane filter method for coliform detection in potable water samples.

    PubMed Central

    Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A

    1986-01-01

    A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953

  14. Total coliform and Escherichia coli contamination in rural well water: analysis for passive surveillance.

    PubMed

    Invik, Jesse; Barkema, Herman W; Massolo, Alessandro; Neumann, Norman F; Checkley, Sylvia

    2017-10-01

    With increasing stress on our water resources and recent waterborne disease outbreaks, understanding the epidemiology of waterborne pathogens is crucial to build surveillance systems. The purpose of this study was to explore techniques for describing microbial water quality in rural drinking water wells, based on spatiotemporal analysis, time series analysis and relative risk mapping. Tests results for Escherichia coli and coliforms from private and small public well water samples, collected between 2004 and 2012 in Alberta, Canada, were used for the analysis. Overall, 14.6 and 1.5% of the wells were total coliform and E. coli-positive, respectively. Private well samples were more often total coliform or E. coli-positive compared with untreated public well samples. Using relative risk mapping we were able to identify areas of higher risk for bacterial contamination of groundwater in the province not previously identified. Incorporation of time series analysis demonstrated peak contamination occurring for E. coli in July and a later peak for total coliforms in September, suggesting a temporal dissociation between these indicators in terms of groundwater quality, and highlighting the potential need to increase monitoring during certain periods of the year.

  15. Comparison of MI, Chromocult® coliform, and Compass CC chromogenic culture-based methods to detect Escherichia coli and total coliforms in water using 16S rRNA sequencing for colony identification.

    PubMed

    Maheux, Andrée F; Bouchard, Sébastien; Bérubé, Ève; Bergeron, Michel G

    2017-06-01

    The MI, Chromocult ® coliform, and Compass CC chromogenic culture-based methods used to assess water quality by the detection of Escherichia coli and total coliforms were compared in terms of their specificity and sensitivity, using 16S rRNA sequencing for colony identification. A sewage water sample was divided in 2-μL subsamples for testing by all three culture-based methods. All growing colonies were harvested and subjected to 16S rRNA sequencing. Test results showed that all E. coli colonies were correctly identified by all three methods, for a specificity and a sensitivity of 100%. However, for the total coliform detection, the MI agar, Chromocult ® coliform agar, and Compass CC agar were specific for only 69.2% (9/13), 47.2% (25/53), and 40.5% (17/42), whereas sensitive for 97.8% (45/46), 97.5% (39/40), and 85.7% (24/28), respectively. Thus, given the low level of specificity of these methods for the detection of total coliforms, confirming the identity of total coliform colonies could help to take public health decisions, in particular for cities connected to a public drinking water distribution system since the growth of few putative total coliform colonies on chromogenic agar is problematic and can lead to unnecessary and costly boiling notices from public health authorities.

  16. A Revised Total Coliform Rule Guide for Small Public Water Systems

    EPA Pesticide Factsheets

    This document aims to assist small water systems serving 1,000 persons with fewer in complying with the requirements of the Revised Total Coliform Rule (RTCR). It is divided into four parts, Parts A, B, C and D.

  17. 75 FR 18205 - Total Coliform Rule Revisions-Notice of Stakeholder Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-09

    ... Coliform Rule (RTCR) and the Distribution Systems Research and Information Collection Partnership... reviewing the methods approved to analyze drinking water samples to determine the presence of total... ( [email protected] , (202) 564-1781, Standards and Risk Management Division, Office of Ground Water and...

  18. 33 CFR 159.319 - Fecal coliform and total suspended solids standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... suspended solids standards. 159.319 Section 159.319 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... Certain Alaskan Waters by Cruise Vessel Operations § 159.319 Fecal coliform and total suspended solids... solids greater than 150 mg/l. (b) Graywater effluent discharges. [Reserved] ...

  19. 33 CFR 159.319 - Fecal coliform and total suspended solids standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... suspended solids standards. 159.319 Section 159.319 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... Certain Alaskan Waters by Cruise Vessel Operations § 159.319 Fecal coliform and total suspended solids... solids greater than 150 mg/l. (b) Graywater effluent discharges. [Reserved] ...

  20. Public Notification Instructions and Templates for the Revised Total Coliform Rule (RTCR)

    EPA Pesticide Factsheets

    EPA has developed public notification (PN) templates to help with implementation of the PN Rule. This document aims to assist water systems with the Public Notification requirements specific to the Revised Total Coliform Rule (RTCR).

  1. 33 CFR 159.127 - Safety coliform count: Recirculating devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety coliform count....127 Safety coliform count: Recirculating devices. Thirty-eight of forty samples of flush fluid from a recirculating device must have less than 240 fecal coliform bacteria per 100 milliliters. These samples must be...

  2. Exploring the Role of Coliform Bacteria in Class 1 Integron Carriage and Biofilm Formation During Drinking Water Treatment.

    PubMed

    Farkas, Anca; Crăciunaş, Cornelia; Chiriac, Cecilia; Szekeres, Edina; Coman, Cristian; Butiuc-Keul, Anca

    2016-11-01

    This study investigates the role of coliforms in the carriage of class 1 integron and biocide resistance genes in a drinking water treatment plant and explores the relationship between the carriage of such genes and the biofouling abilities of the strain. The high incidence of class 1 integron and biocide resistance genes (33.3 % of the isolates) highlights the inherent risk of genetic contamination posed by coliform populations during drinking water treatment. The association between the presence of intI1 gene and qac gene cassettes, especially qacH, was greater in biofilm cells. In coliforms recovered from biofilms, a higher frequency of class 1 integron elements and higher diversity of genetic patterns occurred, compared to planktonic cells. The coliform isolates under the study proved to mostly carry non-classical class 1 integrons lacking the typical qacEΔ1/sul1 genes or a complete tni module, but bearing the qacH gene. No link was found between the carriage of integron genes and the biofouling degree of the strain, neither in aerobic or in anaerobic conditions. Coliform bacteria isolated from established biofilms rather adhere in oxygen depleted environments, while the colonization ability of planktonic cells is not significantly affected by oxygen availability.

  3. Oxytetracycline-Resistant Coliforms in Commercial Poultry Products

    PubMed Central

    Corey, R. Reece; Byrnes, Joseph M.

    1963-01-01

    The presence of oxytetracycline-resistant bacteria was investigated with commercially frozen chicken thighs and drumsticks. Bacterial flora were surveyed by means of total and coliform counts with Tryptone Glucose Extract Agar and Desoxycholate Agar, respectively. After counting, the Desoxycholate Agar plates were replicated on the same medium containing 25, 50, 75, and 100 ppm of oxytetracycline. Resistant colonies were found on all samples that were replicated. Of 2613 colonies isolated on Desoxycholate Agar, 47.8% grew in the presence of 25 ppm of oxytetracycline. From 50 to 100 ppm, the number of resistant isolates remained essentially the same, near 34%. Of 812 colonies of antibiotic-resistant bacteria identified with dulcitol-lactose-iron-agar, 82.5% were paracolons, 13.7% were pseudomonads, and 3.8% were Escherichia or Aerobacter. Bacteria resistant to oxytetracycline were shown to be present on commercially processed chicken. The origin of the resistance to oxytetracycline was not established; however, since the antibiotic was not used during processing, it appeared that these antibiotic-resistant bacteria arose in the intestines of the chickens as a result of feed which contained antibiotic. This is supported by a comparison with the antibiotic resistance of coliforms from chickens raised on feed both with and without oxytetracycline, for the percentages of resistant colonies are similar in both commercial chicken and chicken raised on feed containing the antibiotic. PMID:14075046

  4. EFFECT OF OZONATED WATER ON THE ASSIMILABLE ORGANIC CARBON AND COLIFORM GROWTH RESPONSE VALUES AND ON PATHOGENIC BACTERIA SURVIVAL

    EPA Science Inventory

    The assimilable organic carbon (AOC) and coliform growth response (CGR) are bioassays used to determine water quality. AOC and CGR are better indexes in determining whether water can support the growth of bacteria than biological oxygen demand (BOD). The AOC value of reconditione...

  5. Changes in abundance of heterotrophic and coliform bacteria resident in stored water bodies in relation to incoming bacterial loads following rain events.

    PubMed

    Martin, Anthony Richard; Coombes, Peter John; Harrison, Tracey Lee; Hugh Dunstan, R

    2010-01-01

    Microbial properties of harvested rainwater were assessed at two study sites at Newcastle on the east coast of Australia. The investigation monitored daily counts of heterotrophic bacteria (HPC), total coliforms and E. coli during a mid-winter month (July). Immediately after a major rainfall event, increases in bacterial loads were observed at both sites, followed by gradual reductions in numbers to prior baseline levels within 7 days. Baseline HPC levels ranged from 500-1000 cfu/mL for the sites evaluated, and the loads following rain peaked at 3590-6690 cfu/mL. Baseline levels of total coliforms ranged from 0-100 cfu/100 mL and peaked at 480-1200 cfu/100 mL following rain. At Site 1, there was no evidence of E. coli loading associated with the rain events assessed, and Site 2 had no detectable E.coli colonies at baseline, with a peak load of 17 cfu/100 mL following rain which again diminished to baseline levels. It was concluded that rainfall events contributed to the bacterial load in rainwater storage systems, but processes within the rainwater storage ensured these incoming loads were not sustained.

  6. Removal of Total Coliforms, Thermotolerant Coliforms, and Helminth Eggs in Swine Production Wastewater Treated in Anaerobic and Aerobic Reactors

    PubMed Central

    Zacarias Sylvestre, Silvia Helena; Lux Hoppe, Estevam Guilherme; de Oliveira, Roberto Alves

    2014-01-01

    The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 105 and 109 MPN (100 mL)−1, while helminth eggs ranged from 0.86 to 9.27 eggs g−1 TS. PMID:24812560

  7. Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa.

    PubMed

    Mellor, Jonathan E; Smith, James A; Samie, Amidou; Dillingham, Rebecca A

    2013-09-01

    Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household ( n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm 2 ; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μ max , of 0.072 ± 0.003 h -1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth.

  8. Coliform Sources and Mechanisms for Regrowth in Household Drinking Water in Limpopo, South Africa

    PubMed Central

    Mellor, Jonathan E.; Samie, Amidou; Dillingham, Rebecca A.

    2014-01-01

    Resource-limited communities throughout the developing world face significant environmental health problems related to the myriad of coliform sources within those communities. This study comprehensively investigated contamination sources and the biological and chemical mechanisms sustaining them in two adjacent communities in rural Limpopo, South Africa. An 8-month study was conducted of household (n = 14) and source water quality, measurements of biofilm layers on the inside of household water storage containers and water transfer devices, and also hand-based coliforms and hand-washing effectiveness. A 7-day water container incubation experiment was also performed to determine the biological and chemical changes that occur in a household water storage container independent of human interference. Results indicate that household drinking water frequently becomes contaminated after collection but before consumption (197 versus 1,046 colony-forming units/100 mL; n = 266; p < 0.001). The most important contamination sources include biofilm layers on the inside of storage containers (1.85 ± 1.59 colony-forming units/cm2; n = 44), hands (5,097 ± 2,125 colony-forming units/hand; n = 48), and coliform regrowth resulting from high assimilable organic carbon (AOC) levels during storage. A maximum specific growth rate, μmax, of 0.072 ± 0.003 h−1 was determined for total coliform bacteria on AOC, and a high correlation between AOC concentrations and the growth potential of total coliform bacteria was observed. These results support the implementation of point-of-use water treatment and other interventions aimed at maintaining the safe water chain and preventing biological regrowth. PMID:25190902

  9. Irrigation waters and pipe-based biofilms as sources for antibiotic-resistant bacteria.

    PubMed

    Blaustein, Ryan A; Shelton, Daniel R; Van Kessel, Jo Ann S; Karns, Jeffrey S; Stocker, Matthew D; Pachepsky, Yakov A

    2016-01-01

    The presence of antibiotic-resistant bacteria in environmental surface waters has gained recent attention. Wastewater and drinking water distribution systems are known to disseminate antibiotic-resistant bacteria, with the biofilms that form on the inner-surfaces of the pipeline as a hot spot for proliferation and gene exchange. Pipe-based irrigation systems that utilize surface waters may contribute to the dissemination of antibiotic-resistant bacteria in a similar manner. We conducted irrigation events at a perennial stream on a weekly basis for 1 month, and the concentrations of total heterotrophic bacteria, total coliforms, and fecal coliforms, as well as the concentrations of these bacterial groups that were resistant to ampicillin and tetracycline, were monitored at the intake water. Prior to each of the latter three events, residual pipe water was sampled and 6-in. sections of pipeline (coupons) were detached from the system, and biofilm from the inner-wall was removed and analyzed for total protein content and the above bacteria. Isolates of biofilm-associated bacteria were screened for resistance to a panel of seven antibiotics, representing five antibiotic classes. All of the monitored bacteria grew substantially in the residual water between irrigation events, and the biomass of the biofilm steadily increased from week to week. The percentages of biofilm-associated isolates that were resistant to antibiotics on the panel sometimes increased between events. Multiple-drug resistance was observed for all bacterial groups, most often for fecal coliforms, and the distributions of the numbers of antibiotics that the total coliforms and fecal coliforms were resistant to were subject to change from week to week. Results from this study highlight irrigation waters as a potential source for antibiotic-resistant bacteria, which can subsequently become incorporated into and proliferate within irrigation pipe-based biofilms.

  10. Microbiological Quality of Ready-to-Eat Vegetables Collected in Mexico City: Occurrence of Aerobic-Mesophilic Bacteria, Fecal Coliforms, and Potentially Pathogenic Nontuberculous Mycobacteria

    PubMed Central

    Cerna-Cortes, Jorge Francisco; Leon-Montes, Nancy; Cortes-Cueto, Ana Laura; Salas-Rangel, Laura P.; Helguera-Repetto, Addy Cecilia; Lopez-Hernandez, Daniel; Rivera-Gutierrez, Sandra; Fernandez-Rendon, Elizabeth; Gonzalez-y-Merchand, Jorge Alberto

    2015-01-01

    The aims of this study were to evaluate the microbiological quality and the occurrence of nontuberculous mycobacteria (NTM) in a variety of salads and sprouts from supermarkets and street vendors in Mexico City. Aerobic-mesophilic bacteria (AMB) were present in 100% of RTE-salads samples; 59% of samples were outside guidelines range (>5.17 log10 CFU per g). Although fecal coliforms (FC) were present in 32% of samples, only 8% of them exceeded the permissible limit (100 MPN/g). Regarding the 100 RTE-sprouts, all samples were also positive for AMB and total coliforms (TC) and 69% for FC. Seven NTM species were recovered from 7 salad samples; they included three M. fortuitum, two M. chelonae, one M. mucogenicum, and one M. sp. Twelve RTE-sprouts samples harbored NTM, which were identified as M. porcinum (five), M. abscessus (two), M. gordonae (two), M. mucogenicum (two), and M. avium complex (one). Most RTE-salads and RTE-sprouts had unsatisfactory microbiological quality and some harbored NTM associated with illness. No correlation between the presence of coliforms and NTM was found. Overall, these results suggest that RTE-salads and RTE-sprouts might function as vehicles for NTM transmission in humans; hence, proper handling and treatment before consumption of such products might be recommendable. PMID:25918721

  11. Microbiological Quality of Ready-to-Eat Vegetables Collected in Mexico City: Occurrence of Aerobic-Mesophilic Bacteria, Fecal Coliforms, and Potentially Pathogenic Nontuberculous Mycobacteria.

    PubMed

    Cerna-Cortes, Jorge Francisco; Leon-Montes, Nancy; Cortes-Cueto, Ana Laura; Salas-Rangel, Laura P; Helguera-Repetto, Addy Cecilia; Lopez-Hernandez, Daniel; Rivera-Gutierrez, Sandra; Fernandez-Rendon, Elizabeth; Gonzalez-y-Merchand, Jorge Alberto

    2015-01-01

    The aims of this study were to evaluate the microbiological quality and the occurrence of nontuberculous mycobacteria (NTM) in a variety of salads and sprouts from supermarkets and street vendors in Mexico City. Aerobic-mesophilic bacteria (AMB) were present in 100% of RTE-salads samples; 59% of samples were outside guidelines range (>5.17 log10 CFU per g). Although fecal coliforms (FC) were present in 32% of samples, only 8% of them exceeded the permissible limit (100 MPN/g). Regarding the 100 RTE-sprouts, all samples were also positive for AMB and total coliforms (TC) and 69% for FC. Seven NTM species were recovered from 7 salad samples; they included three M. fortuitum, two M. chelonae, one M. mucogenicum, and one M. sp. Twelve RTE-sprouts samples harbored NTM, which were identified as M. porcinum (five), M. abscessus (two), M. gordonae (two), M. mucogenicum (two), and M. avium complex (one). Most RTE-salads and RTE-sprouts had unsatisfactory microbiological quality and some harbored NTM associated with illness. No correlation between the presence of coliforms and NTM was found. Overall, these results suggest that RTE-salads and RTE-sprouts might function as vehicles for NTM transmission in humans; hence, proper handling and treatment before consumption of such products might be recommendable.

  12. Comparison of total coliform, fecal coliform, and enterococcus bacterial indicator response for ocean recreational water quality testing.

    PubMed

    Noble, R T; Moore, D F; Leecaster, M K; McGee, C D; Weisberg, S B

    2003-04-01

    In July 1999, California's ocean recreational bacterial water quality standards were changed from a total coliform (TC) test to a standard requiring testing for all three bacterial indicators: TC, fecal coliforms (FC), and enterococci (EC). To compare the relationship between the bacterial indicators, and the effect that changing the standards would have on recreational water regulatory actions, three regional studies were conducted along the southern California shoreline from Santa Barbara to San Diego, California. Two studies were conducted during dry weather and one following a large storm event. In each study, samples were collected at over 200 sites which were selected using a stratified random design, with strata consisting of open beach areas and rocky shoreline, and areas near freshwater outlets that drain land-based runoff. During the dry weather studies, samples were collected once per week for 5 weeks. For the storm event study, sampling occurred on a single day about 24 h following the storm. The three indicator bacteria were measured at each site and the results were compared to the single sample standards (TC > 10,000; FC > 400 and EC > 104 MPN or cfu/100 ml). EC was the indicator that failed the single sample standards most often. During the wet weather study, 99% of all standard failures were detected using EC, compared with only 56% for FC, and 40% for TC. During the Summer Study, EC was again the indicator that failed the single sample standards most often, with 60% of the failures for EC alone. The increased failure of the EC standard occurred consistently regardless of whether the sample was collected at a beach or rocky shoreline site, or at a site near a freshwater outlet. Agreement among indicators was better during wet weather than during dry weather. During dry weather, agreement among indicators was better near freshwater outlets than along open shoreline. Cumulatively, our results suggest that replacement of a TC standard with an EC

  13. Fecal-coliform bacteria concentrations in streams of the Chattahoochee River National Recreation Area, Metropolitan Atlanta, Georgia, May-October 1994 and 1995

    USGS Publications Warehouse

    Gregory, M. Brian; Frick, Elizabeth A.

    2000-01-01

    Introduction: The Metropolitan Atlanta area has been undergoing a period of rapid growth and development. The population in the 10-county metropolitan area almost doubled from about 1.5 million people in 1970 to 2.9 million people in 1995 (Atlanta Regional Commission, written commun., 2000). Residential, commercial, and other urban land uses more than tripled during the same period (Frick and others, 1998). The Chattahoochee River is the most utilized water resource in Georgia. The rapid growth of Metropolitan Atlanta and its location downstream of the headwaters of the drainage basin make the Chattahoochee River a vital resource for drinking-water supplies, recreational opportunities, and wastewater assimilation. In 1978, the U.S. Congress declared the natural, scenic, recreation, and other values of 48 miles of the Chattahoochee River from Buford Dam to Peachtree Creek to be of special national significance. To preserve this reach of the Chattahoochee River, the U.S. Congress created the Chattahoochee River National Recreational Area (CRNRA), which includes the Chattahoochee River downstream from Buford Dam to the mouth of Peachtree Creek and a series of park areas adjacent to the river in northern Metropolitan Atlanta Even with this protection, waters of the Chattahoochee River and many of its tributaries in Metropolitan Atlanta did not meet water-quality standards set for designated uses during 1994 and 1995 (fig. 1 and table 1). Much of the degradation of water quality has been associated with areas undergoing rapid urban growth and sprawling suburban development. The resulting conversion of mostly forested land to urban land has multiple adverse effects on water quality. Degradation of water quality may be caused by a number of factors including an increase in nutrient concentrations, sediment and sedimentbound contaminant concentrations (e.g., metals and pesticides) (Frick and others, 1998), and fecal-coliform bacteria concentrations (Center for Watershed

  14. Anti-Biofilm Activity of Polyazolidinammonium Modified with Iodine Hydrate Ions against Microbial Biofilms of Uropathogenic Coliform Bacteria.

    PubMed

    Nechaeva, O V; Tikhomirova, E I; Zayarsky, D A; Bespalova, N V; Glinskaya, E V; Shurshalova, N F; Al Bayati, B M; Babailova, A I

    2017-04-01

    The dynamics of microbial biofilm formation by standard strain and by clinical strains of uropathogenic coliform bacteria was investigated in vitro and the effect of sublethal concentrations of the polymer compound polyazolidinammonium modified with iodine hydrate ions on the initial stages of biofilm formation was assessed. Treatment of immunological plate wells with the polymeric compound prevented film formation, especially in case of clinical E. coli strain carrying FimH virulence gene.

  15. Immunological Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins

    DTIC Science & Technology

    1981-09-01

    FA, Engert RF: Immunological interrelationships between cholera toxin and the heat -labile and hoat-stable enterotoxins of coliform bacteria. Infec...Immun 18:110, 1977 2. Klipstein FA, Engert RF: Immunological relationship of different preparations of coliform enterotoxins. Infec Immun 21:771, 1978...3. Klipstein FA, Engert RF: Reversal of jejunal water secretion by glucose in rats exposed to coliform enterotoxins. Gastroenteroloj y 75:255, 1978 4

  16. Detection of coliform bacteria and Escherichia coli by multiplex polymerase chain reaction: comparison with defined substrate and plating methods for water quality monitoring.

    PubMed Central

    Bej, A K; McCarty, S C; Atlas, R M

    1991-01-01

    Multiplex polymerase chain reaction (PCR) and gene probe detection of target lacZ and uidA genes were used to detect total coliform bacteria and Escherichia coli, respectively, for determining water quality. In tests of environmental water samples, the lacZ PCR method gave results statistically equivalent to those of the plate count and defined substrate methods accepted by the U.S. Environmental Protection Agency for water quality monitoring and the uidA PCR method was more sensitive than 4-methylumbelliferyl-beta-D-glucuronide-based defined substrate tests for specific detection of E. coli. Images PMID:1768116

  17. Radiometric Method for the Detection of Coliform Organisms in Water

    PubMed Central

    Bachrach, Uriel; Bachrach, Zelilah

    1974-01-01

    A new radiometric method for the detection of coliform bacteria in water has been described. The method is based on the release of 14CO2 from [14C]lactose by bacteria suspended in growth medium and incubated at 37 C. The evolved 14CO2 is trapped by hyamine hydroxide and counted in a liquid scintillation spectrometer. The method permits the detection of 1 to 10 organisms within 6 h of incubation. Coliform bacteria suspended in water for several days recover from starvation and may be quantitated by the proposed method. Bacteria from water samples may also be concentrated by filtration through membrane filters and detected by the radiometric assay. PMID:4605007

  18. CORRELATION OF COLIFORM GROWTH RESPONSE WITH OTHER WATER QUALITY PARAMETERS

    EPA Science Inventory

    A variety of water types collected from different geographical areas at different stages of water treatment were anlayzed for their ability to support the growth of coliform bacteria. Based on this coliform bioassay, the nutrient status of the water did not correlate with any of...

  19. Revised Total Coliform Rule Implementation in Wyoming and on Tribal Lands in EPA Region 8

    EPA Pesticide Factsheets

    The Revised Total Coliform Rule (RTCR) aims to increase public health protection through the reduction of potential pathways for fecal contamination in the distribution system of a public water system (PWS).

  20. Evaluation of the methods for enumerating coliform bacteria from water samples using precise reference standards.

    PubMed

    Wohlsen, T; Bates, J; Vesey, G; Robinson, W A; Katouli, M

    2006-04-01

    To use BioBall cultures as a precise reference standard to evaluate methods for enumeration of Escherichia coli and other coliform bacteria in water samples. Eight methods were evaluated including membrane filtration, standard plate count (pour and spread plate methods), defined substrate technology methods (Colilert and Colisure), the most probable number method and the Petrifilm disposable plate method. Escherichia coli and Enterobacter aerogenes BioBall cultures containing 30 organisms each were used. All tests were performed using 10 replicates. The mean recovery of both bacteria varied with the different methods employed. The best and most consistent results were obtained with Petrifilm and the pour plate method. Other methods either yielded a low recovery or showed significantly high variability between replicates. The BioBall is a very suitable quality control tool for evaluating the efficiency of methods for bacterial enumeration in water samples.

  1. Delayed accumulation of intestinal coliform bacteria enhances life span and stress resistance in Caenorhabditis elegans fed respiratory deficient E. coli.

    PubMed

    Gomez, Fernando; Monsalve, Gabriela C; Tse, Vincent; Saiki, Ryoichi; Weng, Emily; Lee, Laura; Srinivasan, Chandra; Frand, Alison R; Clarke, Catherine F

    2012-12-20

    Studies with the nematode model Caenorhabditis elegans have identified conserved biochemical pathways that act to modulate life span. Life span can also be influenced by the composition of the intestinal microbiome, and C. elegans life span can be dramatically influenced by its diet of Escherichia coli. Although C. elegans is typically fed the standard OP50 strain of E. coli, nematodes fed E. coli strains rendered respiratory deficient, either due to a lack coenzyme Q or the absence of ATP synthase, show significant life span extension. Here we explore the mechanisms accounting for the enhanced nematode life span in response to these diets. The intestinal load of E. coli was monitored by determination of worm-associated colony forming units (cfu/worm or coliform counts) as a function of age. The presence of GFP-expressing E. coli in the worm intestine was also monitored by fluorescence microscopy. Worms fed the standard OP50 E. coli strain have high cfu and GFP-labeled bacteria in their guts at the L4 larval stage, and show saturated coliform counts by day five of adulthood. In contrast, nematodes fed diets of respiratory deficient E. coli lacking coenzyme Q lived significantly longer and failed to accumulate bacteria within the lumen at early ages. Animals fed bacteria deficient in complex V showed intermediate coliform numbers and were not quite as long-lived. The results indicate that respiratory deficient Q-less E. coli are effectively degraded in the early adult worm, either at the pharynx or within the intestine, and do not accumulate in the intestinal tract until day ten of adulthood. The findings of this study suggest that the nematodes fed the respiratory deficient E. coli diet live longer because the delay in bacterial colonization of the gut subjects the worms to less stress compared to worms fed the OP50 E. coli diet. This work suggests that bacterial respiration can act as a virulence factor, influencing the ability of bacteria to colonize and

  2. Development and validation of a FISH-based method for the detection and quantification of E. coli and coliform bacteria in water samples.

    PubMed

    Hügler, Michael; Böckle, Karin; Eberhagen, Ingrid; Thelen, Karin; Beimfohr, Claudia; Hambsch, Beate

    2011-01-01

    Monitoring of microbiological contaminants in water supplies requires fast and sensitive methods for the specific detection of indicator organisms or pathogens. We developed a protocol for the simultaneous detection of E. coli and coliform bacteria based on the Fluorescence in situ Hybridization (FISH) technology. This protocol consists of two approaches. The first allows the direct detection of single E. coli and coliform bacterial cells on the filter membranes. The second approach includes incubation of the filter membranes on a nutrient agar plate and subsequent detection of the grown micro-colonies. Both approaches were validated using drinking water samples spiked with pure cultures and naturally contaminated water samples. The effects of heat, chlorine and UV disinfection were also investigated. The micro-colony approach yielded very good results for all samples and conditions tested, and thus can be thoroughly recommended for usage as an alternative method to detect E. coli and coliform bacteria in water samples. However, during this study, some limitations became visible for the single cell approach. The method cannot be applied for water samples which have been disinfected by UV irradiation. In addition, our results indicated that green fluorescent dyes are not suitable to be used with chlorine disinfected samples.

  3. Development of a sensitive chemiluminometric assay for the detection of beta-galactosidase in permeabilized coliform bacteria and comparison with fluorometry and colorimetry.

    PubMed Central

    Van Poucke, S O; Nelis, H J

    1995-01-01

    We developed a chemiluminometric assay of beta-galactosidase in coliform bacteria, using a phenylgalactose-substituted 1,2-dioxetane derivative as a substrate. Permeabilization of cells is required to ensure the efficient cellular uptake of this compound. By this method, one coliform seeded in 100 ml of sterile water can be detected after a 6- to 9-h propagation phase followed by a 45-min enzyme assay in the presence of polymyxin B. Compared with fluorometry and colorimetry, chemiluminometry afforded 4- and 1,000-fold increases in sensitivity and 1- and 6-h increases in the speed of detection, respectively. PMID:8534120

  4. Memo Clarifying Requirements and State Reporting Guidance to Transition to the Revised Total Coliform Rule

    EPA Pesticide Factsheets

    This memorandum provides guidance to primacy agencies with enforcement responsibility under the Safe Drinking Water Act (SDWA) concerning the requirements to transition public water systems (PWSs) from the Total Coliform Rule (TCR) to the RTCR

  5. 75 FR 14607 - Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0141] Small Entity Compliance Guide: Bottled Water: Total Coliform and E. coli; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing...

  6. Relation between selected well-construction characteristics and occurrence of bacteria in private household-supply wells, south-central and southeastern Pennsylvania

    USGS Publications Warehouse

    Zimmerman, Tammy M.; Zimmerman, Michele L.; Lindsey, Bruce D.

    2001-01-01

    Total coliform and Escherichia coli (E. coli) bacteria were analyzed in ground water sampled from 78 private household-supply wells as part of a study by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Environmental Protection to evaluate the relation between well construction characteristics and the occurrence of bacteria in ground water. Sampling was done in eight counties in south-central and southeastern Pennsylvania from September 2000 to March 2001. All samples were collected from wells in close proximity to agricultural land-use areas.Total coliform bacteria were found in water from 62 percent (48 of 78) of the wells, and bacteria were just as likely to be found in sanitary wells (grouted/loose-fitting well cap or grouted/sanitary sealed well cap) as in nonsanitary wells (nongrouted/ loose-fitting well cap). The areas underlain by carbonate bedrock had the highest percentages of total coliform detected (about 75 percent). Nearly half of the samples collected in the areas underlain by noncarbonate bedrock also were found to have total coliform present. E. coli bacteria were found in water from 10 percent of the wells. Seventeen percent of the samples that were positive for total coliform also were positive for E. coli. The presence of E. coli bacteria was more likely in water from nonsanitary wells. Additionally, the presence of E. coli bacteria was more likely in ground water from wells underlain by carbonate bedrock. A further breakdown of the data into four groups on the basis of sanitary construction and bedrock type indicated the presence of E. coli was more likely in water from nonsanitary wells in areas underlain by carbonate bedrock.Statistical analysis of other well-construction characteristics that might relate to occurrence of bacteria showed that the presence of total coliform bacteria was related to the depth to water-bearing zone in both sanitary and nonsanitary wells in areas underlain by carbonate bedrock

  7. Enzyme Characteristics of β-d-Galactosidase- and β-d-Glucuronidase-Positive Bacteria and Their Interference in Rapid Methods for Detection of Waterborne Coliforms and Escherichia coli

    PubMed Central

    Tryland, I.; Fiksdal, L.

    1998-01-01

    Bacteria which were β-d-galactosidase and β-d-glucuronidase positive or expressed only one of these enzymes were isolated from environmental water samples. The enzymatic activity of these bacteria was measured in 25-min assays by using the fluorogenic substrates 4-methylumbelliferyl-β-d-galactoside and 4-methylumbelliferyl-β-d-glucuronide. The enzyme activity, enzyme induction, and enzyme temperature characteristics of target and nontarget bacteria in assays aimed at detecting coliform bacteria and Escherichia coli were investigated. The potential interference of false-positive bacteria was evaluated. Several of the β-d-galactosidase-positive nontarget bacteria but none of the β-d-glucuronidase-positive nontarget bacteria contained unstable enzyme at 44.5°C. The activity of target bacteria was highly inducible. Nontarget bacteria were induced much less or were not induced by the inducers used. The results revealed large variations in the enzyme levels of different β-d-galactosidase- and β-d-glucuronidase-positive bacteria. The induced and noninduced β-d-glucuronidase activities of Bacillus spp. and Aerococcus viridans were approximately the same as the activities of induced E. coli. Except for some isolates identified as Aeromonas spp., all of the induced and noninduced β-d-galactosidase-positive, noncoliform isolates exhibited at least 2 log units less mean β-d-galactosidase activity than induced E. coli. The noncoliform bacteria must be present in correspondingly higher concentrations than those of target bacteria to interfere in the rapid assay for detection of coliform bacteria. PMID:9501441

  8. Distribution and variability of fecal-indicator bacteria in Scioto and Olentangy rivers in the Columbus, Ohio, area

    USGS Publications Warehouse

    Myers, Donna N.

    1992-01-01

    mean and single-sample Ohio Water Quality Standards for recreation less frequently than E. coli concentrations. The E. coli numerical water-quality standards are more difficult to meet than the fecal coliform standards because they are as much as an order of magnitude lower in some instances. The geometric mean bathing-water and primary-contact standards for fecal-coliform and E. coli bacteria were exceeded in more samples for Olentangy River at Goodale Street than for any other site. The single-sample bathing-water standard for fecal-coliform bacteria was exceeded in 83 percent of all samples and for E. coli in 91 percent of samples for Olentangy River at Goodale Street. Compared to Olentangy River at Goodale Street, geometric means and single-samples exceeded the bathing-water standards somewhat less frequently for Scioto River at Town Street and far less frequently for Scioto River at Dublin Road Water Treatment Plant. In contrast to results for fecal-indicator bacteria, the differences between sites for pH and for concentrations for total alkalinity, total chloride, total nonfilterable residue, total nitrate plus nitrite as nitrogen, total phosphorus, and total organic carbon were small. The large contribution of streamflow and discharge of fecal-indicator bacteria from Olentangy River to Scioto River has a major effect on the Scioto River downstream from the confluence of Olentangy River during periods of rainfall and runoff. Fecal-indicator discharges were calculated for times before, during, and at 24-hour intervals for 48 to 72 hours after two runoff-producing storms. Fecal-coliform and E. coli concentrations were lower in samples collected before runoff and during receding streamflows at 24- to 48-hours after the storms than in samples collected during runoff. The fecal-indicator discharges entering Scioto River from Olentangy River ranged from 22.6 to nearly 100 percent of the total for two storms studied. Controlling nonpoint, unregulated,

  9. Fecal coliforms on environmental surfaces in two day care centers.

    PubMed Central

    Weniger, B G; Ruttenber, A J; Goodman, R A; Juranek, D D; Wahlquist, S P; Smith, J D

    1983-01-01

    A survey of environmental surfaces in two Atlanta area day care centers was conducted to determine the prevalence of fecal coliform bacteria, considered a marker for the presence of fecal contamination which might contain pathogenic parasites, bacteria, or viruses. Fecal coliforms were found in 17 (4.3%) of 398 representative samples of building surfaces, furniture, and other objects. These surfaces may be involved in the chain of transmission of enteric diseases among children. Therefore, disinfection of inanimate objects, in addition to good handwashing, may be important in controlling the spread of enteric diseases in day care centers. PMID:6830225

  10. THE TOTAL COLIFORM RULE AND FUTURE OF THE INDICATORS AND PATHOGENS IN DRINKING WATER ASSESSMENT

    EPA Science Inventory

    This presentation describes some of the major microbiological issues related to drinking water quality of concern to the EPA. The revision process of the Total Coliform Rule and the selection of the Microbial Contaminant List (CCL) are discussed. A brief overview of research co...

  11. Genetic relatedness of faecal coliforms and enterococci bacteria isolated from water and sediments of the Apies River, Gauteng, South Africa.

    PubMed

    Ekwanzala, Mutshiene Deogratias; Abia, Akebe Luther King; Ubomba-Jaswa, Eunice; Keshri, Jitendra; Momba, Ndombo Benteke Maggy

    2017-12-01

    To date, the microbiological quality of river sediments and its impact on water resources are not included in the water quality monitoring assessment. Therefore, the aim of this study was to establish genetic relatedness between faecal coliforms and enterococci isolated from the river water and riverbed sediments of Apies River to better understand the genetic similarity of microorganisms between the sediment and water phases. Indicator bacteria were subjected to a molecular study, which consisted of PCR amplification and sequence analysis of the 16S rRNA and 23S rRNA gene using specific primers for faecal coliforms and enterococci, respectively. Results revealed that the Apies River had high faecal pollution levels with enterococci showing low to moderate correlation coefficient (r 2 values ranged from 0.2605 to 0.7499) compared to the faecal coliforms which showed zero to low correlation (r 2 values ranged from 0.0027 to 0.1407) indicating that enterococci may be better indicator than faecal coliforms for detecting faecal contamination in riverbed sediments. The phylogenetic tree of faecal coliforms revealed a 98% homology among their nucleotide sequences confirming the close genetic relatedness between river water and riverbed sediment isolates. The phylogenetic tree of the enterococci showed that Enterococcus faecalis and Enterococcus faecium are the predominant species found in both river water and riverbed sediments with bootstrap values of ≥99%. A high degree of genetic relatedness between sediment and water isolates indicated a possible common ancestry and transmission pathway. We recommend the microbial monitoring of riverbed sediments as it harbours more diverse microbial community and once resuspended may cause health and environmental problems.

  12. Immunological Interrelationships Between Cholera Toxin and the Heat-Labile and Heat-Stable Enterotoxins of Coliform Bacteria

    PubMed Central

    Klipstein, Frederick A.; Engert, Richard F.

    1977-01-01

    Cholera toxin (CT) and the heat-labile (LT) toxin of Escherichia coli are known to share antigenic properties. The present study examined the immunological relationship of CT and the LT and heat-stable (ST) toxins of E. coli, Klebsiella pneumoniae, and Enterobacter cloacae. The neutralizing capacity of equine CT antiserum and of antiserum raised in rabbits to the LT toxin of the three species of coliform bacteria was evaluated by determining their capacity to inhibit the action of purified CT and semipurified ultrafiltration preparations of the coliform LT and ST toxins in inducing water secretion as assayed by the in vivo marker perfusion technique in the rat jejunum. One milliliter of antiserum to CT and to E. coli and Klebsiella LT completely neutralized the secretory action of each of these three toxins; effective serial dilutions of CT antiserum extended to 1 to 4, whereas those of the antisera to LT were limited to 1 to 2 in most instances. One milliliter of antiserum to E. cloacae LT partially neutralized each of the three coliform LT toxins; serial dilutions were inactive. Antiserum to E. cloacae LT did not neutralize CT. Antiserum to CT and to each of the three coliform LT toxins also had a weak neutralizing effect on the ST toxins of E. coli and Klebsiella, but they did not affect E. cloacae ST. Adsorption of the antiserum to CT and to each of the three LT toxins by incubation with a heat-inactivated preparation of either the homologous or a heterologous LT toxin completely abolished the neutralizing capacity of the antisera towards both LT and ST. These observations indicate that the immunological interrelationship of CT and E. coli LT extends to the LT toxins of Klebsiella and E. cloacae and, further, that these immunological properties are shared to a lesser extent by the ST toxins of E. coli and Klebsiella. PMID:332637

  13. Comparison of the quantitative dry culture methods with both conventional media and most probable number method for the enumeration of coliforms and Escherichia coli/coliforms in food.

    PubMed

    Teramura, H; Sota, K; Iwasaki, M; Ogihara, H

    2017-07-01

    Sanita-kun™ CC (coliform count) and EC (Escherichia coli/coliform count), sheet quantitative culture systems which can avoid chromogenic interference by lactase in food, were evaluated in comparison with conventional methods for these bacteria. Based on the results of inclusivity and exclusivity studies using 77 micro-organisms, sensitivity and specificity of both Sanita-kun™ met the criteria for ISO 16140. Both media were compared with deoxycholate agar, violet red bile agar, Merck Chromocult™ coliform agar (CCA), 3M Petrifilm™ CC and EC (PEC) and 3-tube MPN, as reference methods, in 100 naturally contaminated food samples. The correlation coefficients of both Sanita-kun™ for coliform detection were more than 0·95 for all comparisons. For E. coli detection, Sanita-kun™ EC was compared with CCA, PEC and MPN in 100 artificially contaminated food samples. The correlation coefficients for E. coli detection of Sanita-kun™ EC were more than 0·95 for all comparisons. There were no significant differences in all comparisons when conducting a one-way analysis of variance (anova). Both Sanita-kun™ significantly inhibited colour interference by lactase when inhibition of enzymatic staining was assessed using 40 natural cheese samples spiked with coliform. Our results demonstrated Sanita-kun™ CC and EC are suitable alternatives for the enumeration of coliforms and E. coli/coliforms, respectively, in a variety of foods, and specifically in fermented foods. Current chromogenic media for coliforms and Escherichia coli/coliforms have enzymatic coloration due to breaking down of chromogenic substrates by food lactase. The novel sheet culture media which have film layer to avoid coloration by food lactase have been developed for enumeration of coliforms and E. coli/coliforms respectively. In this study, we demonstrated these media had comparable performance with reference methods and less interference by food lactase. These media have a possibility not only

  14. Immunologic Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins

    DTIC Science & Technology

    1980-01-15

    PUBLICATIONS Supported by Contract No. DAMD 17-77-C-7032 1. Klipstein FA, Engert RF: Immunological interrelationships between cholera toxin and the...heat-labile and heat-stable enterotoxins of coliform bacteria. Infec Immun 18:110, 1977 2. Klipstein FA, Engert RF: Immunological relationship of...different preparations of coliform enterotoxins. Infec Immun 21:771, 1978 3. Klipstein FA, Engert RF: Reversal of jejunal water secretion by glucose in

  15. Immunological Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins

    DTIC Science & Technology

    1981-01-01

    FA, Engert RF: Immunological interrelationships between cholera toxin and the heat-labile and heat-stable enterotoxins of coliforn, bacteria. Infec...Irnmun 18:110, 1977 2. Klipstein FA, Engert RF: Immunological relaticnsh~p of different preparations of coliform enterotoxins. Infec Immun 21:771, 1918...3 Klipstein FA, Engert RF: Reversal of jejunal water secretion by glucose in rats exposed to coliform enterotoxcins. Gastroenterology 75:255, 1978 4

  16. Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques.

    PubMed Central

    Evans, T M; LeChevallier, M W; Waarvick, C E; Seidler, R J

    1981-01-01

    The species of total coliform bacteria isolated from drinking water and untreated surface water by the membrane filter (MF), the standard most-probable-number (S-MPN), and modified most-probable-number (M-MPN) techniques were compared. Each coliform detection technique selected for a different profile of coliform species from both types of water samples. The MF technique indicated that Citrobacter freundii was the most common coliform species in water samples. However, the fermentation tube techniques displayed selectivity towards the isolation of Escherichia coli and Klebsiella. The M-MPN technique selected for more C. freundii and Enterobacter spp. from untreated surface water samples and for more Enterobacter and Klebsiella spp. from drinking water samples than did the S-MPN technique. The lack of agreement between the number of coliforms detected in a water sample by the S-MPN, M-MPN, and MF techniques was a result of the selection for different coliform species by the various techniques. PMID:7013706

  17. Comparison of four β-glucuronidase and β-galactosidase-based commercial culture methods used to detect Escherichia coli and total coliforms in water.

    PubMed

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bouchard, Sébastien; Bisson, Marc-Antoine; Bergeron, Michel G; Rodriguez, Manuel J

    2015-06-01

    The MI agar, Colilert(®), Chromocult coliform(®) agar, and DC with BCIG agar chromogenic culture-based methods used to assess microbiological quality of drinking water were compared in terms of their ubiquity, sensitivity, ease of use, growth of atypical colonies and affordability. For ubiquity, 129 total coliform (representing 76 species) and 19 Escherichia coli strains were tested. Then, 635 1-L well water samples were divided into 100 mL subsamples for testing by all four methods. Test results showed that 70.5, 52.7, 36.4, and 23.3% of the non-E. coli total coliform strains and 94.7, 94.7, 89.5, and 89.5% of the 19 E. coli strains yielded a positive signal with the four methods, respectively. They also yielded a total coliform positive signal for 66.5, 51.7, 64.9, and 55.0% and an E. coli positive signal for 16.1, 14.8, 17.3, and 13.4% of the 635 well water samples tested, respectively. Results showed that Colilert(®) is the most expensive method tested in terms of reactants, yet it is the easiest to use. Large numbers of atypical colonies were also often observed on Chromocult coliform(®) and DC with BCIG, thereby challenging the target microorganism count. Thus, the MI agar method seems to be the best option for the assessment of drinking water quality.

  18. Method and automated apparatus for detecting coliform organisms

    NASA Technical Reports Server (NTRS)

    Dill, W. P.; Taylor, R. E.; Jeffers, E. L. (Inventor)

    1980-01-01

    Method and automated apparatus are disclosed for determining the time of detection of metabolically produced hydrogen by coliform bacteria cultured in an electroanalytical cell from the time the cell is inoculated with the bacteria. The detection time data provides bacteria concentration values. The apparatus is sequenced and controlled by a digital computer to discharge a spent sample, clean and sterilize the culture cell, provide a bacteria nutrient into the cell, control the temperature of the nutrient, inoculate the nutrient with a bacteria sample, measures the electrical potential difference produced by the cell, and measures the time of detection from inoculation.

  19. Regulation of the Biosynthesis of Amino Acids of the Aspartate Family in Coliform Bacteria and Pseudomonads

    PubMed Central

    Cohen, G. N.; Stanier, R. Y.; Bras, Gisele Le

    1969-01-01

    The control of aspartokinase and homoserine dehydrogenase activities was compared in aerobic and fermentative pseudomonads (genera Pseudomonas and Aeromonas), and in coliform bacteria representative of the principal genera of the Enterobacteriaceae. Isofunctional aspartokinases subject to independent end-product control occur in the Enterobacteriaceae and in Aeromonas. In Pseudomonas, there appears to be a single aspartokinase, subject to concerted feedback inhibition by lysine and threonine. Within this genus, the sensitivity of aspartokinase to the single allosteric inhibitors varies considerably: the aspartokinase of the acidovorans group is little affected by the single inhibitors, whereas that of the fluorescent group is severely inhibited by either amino acid at high concentration. In all bacteria examined, homoserine dehydrogenase activity is inhibited by threonine; inhibition is more severe in aerobic pseudomonads than in the other groups. In most of the bacteria examined, either nicotinamide adenine dinucleotide (NAD) or nicotinamide adenine dinucleotide phosphate can serve as a cofactor for this enzyme, though the relative activity with the two pyridine nucleotides varies widely. Aerobic pseudomonads of the acidovorans group contain a homoserine dehydrogenase that is absolutely specific for NAD. The taxonomic implications of these findings are discussed. PMID:4391829

  20. Elimination of coliforms and Salmonella spp. in sheep meat by gamma irradiation treatment

    PubMed Central

    Henriques, Luciana Salles Vasconcelos; da Costa Henry, Fábio; Barbosa, João Batista; Ladeira, Silvania Alves; de Faria Pereira, Silvia Menezes; da Silva Antonio, Isabela Maria; Teixeira, Gina Nunes; Martins, Meire Lelis Leal; de Carvalho Vital, Helio; dos Prazeres Rodrigues, Dália; dos Reis, Eliane Moura Falavina

    2013-01-01

    This study aimed at evaluating the bacteriological effects of the treatment of sheep meat contaminated with total coliforms, coliforms at 45 °C and Salmonella spp. by using irradiation at doses of 3 kGy and 5 kGy. Thirty sheep meat samples were collected from animals located in Rio de Janeiro State, Brazil, and then grouped in three lots including 10 samples: non-irradiated (control); irradiated with 3 kGy; and irradiated with 5 kGy. Exposure to gamma radiation in a 137Cs source-driven irradiating facility was perfomed at the Nuclear Defense Section of the Brazilian Army Technological Center (CTEx) in Rio de Janeiro. The samples were kept under freezing temperature (−18 °C) until the analyses, which occurred in two and four months after irradiation. The results were interpreted by comparison with the standards of the current legislation and demonstrated that non-irradiated samples were outside the parameters established by law for all groups of bacteria studied. Gamma irradiation was effective in inactivating those microorganisms at both doses tested and the optimal dose was achieved at 3 kGy. The results have shown not only the need for sanitary conditions improvements in slaughter and processing of sheep meat but also the irradiation effectiveness to eliminate coliform bacteria and Salmonella spp. PMID:24688504

  1. [Comparison between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection].

    PubMed

    Sun, Zong-ke; Wu, Rong; Ding, Pei; Xue, Jin-Rong

    2006-07-01

    To compare between rapid detection method of enzyme substrate technique and multiple-tube fermentation technique in water coliform bacteria detection. Using inoculated and real water samples to compare the equivalence and false positive rate between two methods. Results demonstrate that enzyme substrate technique shows equivalence with multiple-tube fermentation technique (P = 0.059), false positive rate between the two methods has no statistical difference. It is suggested that enzyme substrate technique can be used as a standard method for water microbiological safety evaluation.

  2. An Environmental Health Assessment: Fecal Coliform Contamination in San Francisco Waterbodies

    NASA Astrophysics Data System (ADS)

    Devillier, K. N.; Devine, M.; Negrete, R.; Rawley, A. L.; Neiss, J.

    2007-12-01

    Fecal coliform is a group of bacteria that exists in the digestive system and excrement of warm-blooded animals. It enters aquatic environments through fecal contamination of water. In the urban environment, contamination can occur not only by direct input from warm-blooded animals but also from storm water run-off and municipal sewer overflow. Fecal coliform itself does not cause disease but it is an indicator of the presence of pathogens that exist in the wastes of humans and animals that are a hazard to human health. We examined 12 locations in San Francisco for fecal coliform and recorded the types of human contact with water at each location. We found low levels of coliform in areas open to the San Francisco Bay and Pacific Ocean and high levels of coliform in inland lakes and ponds. Using Environmental Protection Agency guidelines for fecal coliform concentrations, we found all sites at acceptable levels for the recreational and human activities we observed.

  3. Health significance and occurrence of injured bacteria in drinking water

    NASA Technical Reports Server (NTRS)

    McFeters, G. A.; LeChevallier, M. W.; Singh, A.; Kippin, J. S.

    1986-01-01

    Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.

  4. Modeling seasonal variability of fecal coliform in natural surface waters using the modified SWAT

    NASA Astrophysics Data System (ADS)

    Cho, Kyung Hwa; Pachepsky, Yakov A.; Kim, Minjeong; Pyo, JongCheol; Park, Mi-Hyun; Kim, Young Mo; Kim, Jung-Woo; Kim, Joon Ha

    2016-04-01

    Fecal coliforms are indicators of pathogens and thereby, understanding of their fate and transport in surface waters is important to protect drinking water sources and public health. We compiled fecal coliform observations from four different sites in the USA and Korea and found a seasonal variability with a significant connection to temperature levels. In all observations, fecal coliform concentrations were relatively higher in summer and lower during the winter season. This could be explained by the seasonal dominance of growth or die-off of bacteria in soil and in-stream. Existing hydrologic models, however, have limitations in simulating the seasonal variability of fecal coliform. Soil and in-stream bacterial modules of the Soil and Water Assessment Tool (SWAT) model are oversimplified in that they exclude simulations of alternating bacterial growth. This study develops a new bacteria subroutine for the SWAT in an attempt to improve its prediction accuracy. We introduced critical temperatures as a parameter to simulate the onset of bacterial growth/die-off and to reproduce the seasonal variability of bacteria. The module developed in this study will improve modeling for environmental management schemes.

  5. Instream coliform gradients in the Holtemme, a small headwater stream in the Elbe River Basin, Northern Germany

    NASA Astrophysics Data System (ADS)

    Karthe, Daniel; Lin, Pei-Ying; Westphal, Katja

    2017-09-01

    The Holtemme is a small headwater stream in North Germany's Elbe River Basin. According to German and European legislation, hygienic monitoring is not mandatory for such water bodies which are neither drinking water sources nor categorized as bathing waters. Consequently, relatively little is known about the occurrence of-potentially pathogenic-bacteria and viruses in Germany's streams and rivers. The Holtemme was selected for a case study because it is relatively well monitored for both chemical water quality and aquatic ecology, but not for hygiene. Originating in the mountains of Harz Nature Park, the 47 km long Holtemme is characterized by a strong longitudinal gradient in chemical water quality, which is related to different land uses and the influx of treated wastewater from two urban areas (Wernigerode and Halberstadt). Waste water loads received by the Holtemme are comparatively high when compared to similarly small streams. In 2015, total coliform concentrations between more than 200 and 77,010 bacteria per 100 mL, and fecal coliform concentrations between 5 and 24,060 bacteria per 100 mL were observed in the Holtemme's main channel. The highest concentrations were typically found below the outlets of the two wastewater treatment plants. The treated wastewater contained total and fecal coliform concentrations of up to 200,500 and 83,100 per 100 mL, respectively; however, there were significant temporal variations. While the observed concentrations are unproblematic from a legal perspective (because no maximum permissible limits are defined for streams in Germany), they would exceed the tolerable limits for bathing waters in the EU, indicating moderate to critical pollution limits.

  6. Assessment of the characteristic of nutrients, total metals, and fecal coliform in Sibu Laut River, Sarawak, Malaysia

    NASA Astrophysics Data System (ADS)

    Soo, Chen-Lin; Ling, Teck-Yee; Lee, Nyanti; Apun, Kasing

    2016-03-01

    The concentrations of nutrients (nitrogen and phosphorus), total metals, and fecal coliform (FC) coupling with chlorophyll- a (chl- a), 5-day biochemical oxygen demand (BOD5) and other general environmental parameters were evaluated at the sub-surface and near-bottom water columns of 13 stations in the Sibu Laut River during low and high slack waters. The results indicated that inorganic nitrogen (mainly nitrate) was the primary form of nitrogen whereas organic phosphorus was the major form of phosphorus. The abundance of total heavy metals in Sibu Laut River and its tributaries was in the order of Pb < Cu < Zn < Cd. Fecal coliform concentration was relatively low along Sibu Laut River. The shrimp farm effluents contributed a substantial amount of chl- a, BOD5, nutrients, and FC to the receiving creek except for total metals. Nevertheless, the influence was merely noticeable in the intake creek and amended rapidly along Selang Sibu River and brought minimal effects on the Sibu Laut River. Besides, the domestic sewage effluents from villages nearby also contributed a substantial amount of pollutants.

  7. The association between bedding material and the bacterial counts of Staphylococcus aureus, Streptococcus uberis and coliform bacteria on teat skin and in teat canals in lactating dairy cattle.

    PubMed

    Paduch, Jan-Hendrik; Mohr, Elmar; Krömker, Volker

    2013-05-01

    Several mastitis-causing pathogens are able to colonize the bovine teat canal. The objective of this study was to investigate the association between the treatment of sawdust bedding with a commercial alkaline conditioner and the bacterial counts on teat skin and in the teat canal. The study used a crossover design. Ten lactating Holstein cows that were free of udder infections and mastitis were included in the study. The animals were bedded on either untreated sawdust or sawdust that had been treated with a hydrated lime-based conditioner. Once a day, fresh bedding material was added. After 3 weeks, the bedding material was removed from the cubicles, fresh bedding material was provided, and the cows were rotated between the two bedding material groups. Teat skin and teat canals were sampled using the wet and dry swab technique after weeks 1, 2, 3, 4, 5 and 6. Staphylococcus aureus, Streptococcus uberis, Escherichia coli and other coliform bacteria were detected in the resulting agar plate cultures. The treatment of the bedding material was associated with the teat skin bacterial counts of Str. uberis, Esch. coli and other coliform bacteria. An association was also found between the bedding material and the teat canal bacterial counts of coliform bacteria other than Esch. coli. For Staph. aureus, no associations with the bedding material were found. In general, the addition of a hydrated lime-based conditioner to sawdust reduces the population sizes of environmental pathogens on teat skin and in teat canals.

  8. The Evolving Role of Coliforms As Indicators of Unhygienic Processing Conditions in Dairy Foods.

    PubMed

    Martin, Nicole H; Trmčić, Aljoša; Hsieh, Tsung-Han; Boor, Kathryn J; Wiedmann, Martin

    2016-01-01

    Testing for coliforms has a long history in the dairy industry and has helped to identify raw milk and dairy products that may have been exposed to unsanitary conditions. Coliform standards are included in a number of regulatory documents (e.g., the U.S. Food and Drug Administration's Grade "A" Pasteurized Milk Ordinance). As a consequence, detection above a threshold of members of this method-defined, but diverse, group of bacteria can result in a wide range of regulatory outcomes. Coliforms are defined as aerobic or facultatively anaerobic, Gram negative, non-sporeforming rods capable of fermenting lactose to produce gas and acid within 48 h at 32-35°C; 19 genera currently include at least some strains that represent coliforms. Most bacterial genera that comprise the coliform group (e.g., Escherichia , Klebsiella , and Serratia ) are within the family Enterobacteriaceae, while at least one genus with strains recognized as coliforms, Aeromonas , is in the family Aeromonadaceae. The presence of coliforms has long been thought to indicate fecal contamination, however, recent discoveries regarding this diverse group of bacteria indicates that only a fraction are fecal in origin, while the majority are environmental contaminants. In the US dairy industry in particular, testing for coliforms as indicators of unsanitary conditions and post-processing contamination is widespread. While coliforms are easily and rapidly detected, and are not found in pasteurized dairy products that have not been exposed to post-processing contamination, advances in knowledge of bacterial populations most commonly associated with post-processing contamination in dairy foods has led to questions regarding the utility of coliforms as indicators of unsanitary conditions for dairy products. For example, Pseudomonas spp. frequently contaminate dairy products after pasteurization, yet they are not detected by coliform tests. This review will address the role that coliforms play in raw and

  9. The Evolving Role of Coliforms As Indicators of Unhygienic Processing Conditions in Dairy Foods

    PubMed Central

    Martin, Nicole H.; Trmčić, Aljoša; Hsieh, Tsung-Han; Boor, Kathryn J.; Wiedmann, Martin

    2016-01-01

    Testing for coliforms has a long history in the dairy industry and has helped to identify raw milk and dairy products that may have been exposed to unsanitary conditions. Coliform standards are included in a number of regulatory documents (e.g., the U.S. Food and Drug Administration’s Grade “A” Pasteurized Milk Ordinance). As a consequence, detection above a threshold of members of this method-defined, but diverse, group of bacteria can result in a wide range of regulatory outcomes. Coliforms are defined as aerobic or facultatively anaerobic, Gram negative, non-sporeforming rods capable of fermenting lactose to produce gas and acid within 48 h at 32–35°C; 19 genera currently include at least some strains that represent coliforms. Most bacterial genera that comprise the coliform group (e.g., Escherichia, Klebsiella, and Serratia) are within the family Enterobacteriaceae, while at least one genus with strains recognized as coliforms, Aeromonas, is in the family Aeromonadaceae. The presence of coliforms has long been thought to indicate fecal contamination, however, recent discoveries regarding this diverse group of bacteria indicates that only a fraction are fecal in origin, while the majority are environmental contaminants. In the US dairy industry in particular, testing for coliforms as indicators of unsanitary conditions and post-processing contamination is widespread. While coliforms are easily and rapidly detected, and are not found in pasteurized dairy products that have not been exposed to post-processing contamination, advances in knowledge of bacterial populations most commonly associated with post-processing contamination in dairy foods has led to questions regarding the utility of coliforms as indicators of unsanitary conditions for dairy products. For example, Pseudomonas spp. frequently contaminate dairy products after pasteurization, yet they are not detected by coliform tests. This review will address the role that coliforms play in raw and

  10. Particle effects on ultraviolet disinfection of coliform bacteria in recycled water.

    PubMed

    Jolis, D; Lam, C; Pitt, P

    2001-01-01

    Pilot- and bench-scale coliform inactivation tests with UV irradiation were used to show how suspended solids remaining in filtered secondary effluent affect the efficiency of the UV disinfection process. Observed kinetic inactivation rates decreased with increasing suspended particle sizes of 7 microm or larger present in tertiary effluent. First-order inactivation rates estimated from collimated beam dose-response curves for discrete ranges of UV doses were substantially different, which should caution researchers not to compare inactivation data obtained with largely dissimilar UV doses or suspended particle distributions. A dose of approximately 800 J/m2 was identified as the minimum dose that will consistently meet the California wastewater reclamation coliform criterion when applied to in-line filtration effluent.

  11. Presence of antimicrobial resistance in coliform bacteria from hatching broiler eggs with emphasis on ESBL/AmpC-producing bacteria.

    PubMed

    Mezhoud, H; Chantziaras, I; Iguer-Ouada, M; Moula, N; Garmyn, A; Martel, A; Touati, A; Smet, A; Haesebrouck, F; Boyen, F

    2016-08-01

    Antimicrobial resistance is recognized as one of the most important global health challenges. Broilers are an important reservoir of antimicrobial resistant bacteria in general and, more particularly, extended-spectrum β-lactamases (ESBL)/AmpC-producing Enterobacteriaceae. Since contamination of 1-day-old chicks is a potential risk factor for the introduction of antimicrobial resistant Enterobacteriaceae in the broiler production chain, the presence of antimicrobial resistant coliform bacteria in broiler hatching eggs was explored in the present study. Samples from 186 hatching eggs, collected from 11 broiler breeder farms, were inoculated on MacConkey agar with or without ceftiofur and investigated for the presence of antimicrobial resistant lactose-positive Enterobacteriaceae, particularly, ESBL/AmpC-producers. Escherichia coli and Enterobacter cloacae were obtained from the eggshells in 10 out of 11 (10/11) sampled farms. The majority of the isolates were recovered from crushed eggshells after external decontamination suggesting that these bacteria are concealed from the disinfectants in the egg shell pores. Antimicrobial resistance testing revealed that approximately 30% of the isolates showed resistance to ampicillin, tetracycline, trimethoprim and sulphonamides, while the majority of isolates were susceptible to amoxicillin-clavulanic acid, nitrofurantoin, aminoglycosides, florfenicol, neomycin and apramycin. Resistance to extended-spectrum cephalosporins was detected in eight Enterobacteriaceae isolates from five different broiler breeder farms. The ESBL phenotype was confirmed by the double disk synergy test and blaSHV-12, blaTEM-52 and blaACT-39 resistance genes were detected by PCR. This report is the first to present broiler hatching eggs as carriers and a potential source of ESBL/AmpC-producing Enterobacteriaceae for broiler chicks.

  12. Description and field test of an in situ coliform monitoring system

    NASA Technical Reports Server (NTRS)

    Grana, D. C.; Wilkins, J. R.

    1979-01-01

    A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

  13. Enteropathogenic Bacteria Contamination of Unchlorinated Drinking Water in Korea, 2010

    PubMed Central

    Lee, Si Won; Lee, Do Kyung; An, Hyang Mi; Cha, Min Kyeong; Kim, Kyung Jae

    2011-01-01

    Objectives The purpose of this study was to assess the microbiological quality of unchlorinated drinking water in Korea, 2010. One hundred and eighty unchlorinated drinking water samples were collected from various sites in Seoul and Gyeonggi province. Methods To investigate bacterial presence, the pour plate method was used with cultures grown on selective media for total bacteria, total coliforms, and Staphylococcus spp., respectively. Results In the 180 total bacteria investigation, 72 samples from Seoul and 33 samples from Gyeonggi province were of an unacceptable quality (>102 CFU/mL). Of all the samples tested, total coliforms were detected in 28 samples (15.6%) and Staphylococcus spp. in 12 samples (6.7%). Most of the coliform isolates exhibited high-level resistance to cefazolin (88.2%), cefonicid (64.7%) and ceftazidime (20.6%). In addition, Staphylococcus spp. isolates exhibited high-level resistance to mupirocin (42%). Species of Pseudomonas, Acinetobacter, Cupriavidus, Hafnia, Rahnella, Serratia, and Yersinia were isolated from the water samples. Conclusions The results of this study suggest that consumption of unchlorinated drinking water could represent a notable risk to the health of consumers. As such, there is need for continuous monitoring of these water sources and to establish standards. PMID:22216417

  14. COMPARISON OF THE RECOVERIES OF ESCHERICHIA COLI AND TOTAL COLIFORMS FROM DRINKING WATER BY THE MI AGAR METHOD AND THE U.S. ENVIRONMENTAL PROTECTION AGENCY-APPROVED MEMBRANE FILTER METHOD

    EPA Science Inventory

    Drinking water regulations under the Final Coliform Rule require that total coliform-positive drinking water samples be examined for the presence of Escherichia coli or fecal coliforms. The current U.S. Environmental Protection Agency-approved membrane filter (MF) method for E. c...

  15. Human Bacteroides and total coliforms as indicators of recent combined sewer overflows and rain events in urban creeks

    USGS Publications Warehouse

    McGinnis, Shannon; Spencer, Susan K.; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark A.; McCarthy, David; Murphy, Heather

    2018-01-01

    Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May–July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs.

  16. Human Bacteroides and total coliforms as indicators of recent combined sewer overflows and rain events in urban creeks.

    PubMed

    McGinnis, Shannon; Spencer, Susan; Firnstahl, Aaron; Stokdyk, Joel; Borchardt, Mark; McCarthy, David T; Murphy, Heather M

    2018-07-15

    Combined sewer overflows (CSOs) are a known source of human fecal pollution and human pathogens in urban water bodies, which may present a significant public health threat. To monitor human fecal contamination in water, bacterial fecal indicator organisms (FIOs) are traditionally used. However, because FIOs are not specific to human sources and do not correlate with human pathogens, alternative fecal indicators detected using qPCR are becoming of interest to policymakers. For this reason, this study measured correlations between the number and duration of CSOs and mm of rainfall, concentrations of traditional FIOs and alternative indicators, and the presence of human pathogens in two urban creeks. Samples were collected May-July 2016 and analyzed for concentrations of FIOs (total coliforms and E. coli) using membrane filtration as well as for three alternative fecal indicators (human Bacteroides HF183 marker, human polyomavirus (HPoV), pepper mild mottle virus (PMMoV)) and nine human pathogens using qPCR. Four of the nine pathogens analyzed were detected at these sites including adenovirus, Enterohemorrhagic E. coli, norovirus, and Salmonella. Among all indicators studied, human Bacteroides and total coliforms were significantly correlated with recent CSO and rainfall events, while E. coli, PMMoV, and HPoV did not show consistent significant correlations. Further, human Bacteroides were a more specific indicator, while total coliforms were a more sensitive indicator of CSO and rainfall events. Results may have implications for the use and interpretation of these indicators in future policy or monitoring programs. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Fecal coliform and Escherichia coli bacteria in the St. Croix National Scenic Riverway, Summer 1999

    USGS Publications Warehouse

    Kroening, Sharon E.

    1999-01-01

    Fecal coliform and Escherichia coli (E. coli) concentrations were determined in the St. Croix National Scenic Riverway to assess whether pathogenic organisms pose a potential problem for recreational use. Samples were collected from May through September 1999 at 22 locations on the St. Croix and Namekagon Rivers. No concentrations exceeded water-quality criteria or standards set by the U.S. Environmental Protection Agency or the states of Minnesota and Wisconsin. Maximum fecal coliform and E. coli concentrations were measured in the St. Croix River at St. Croix Falls, Wisconsin. Median fecal coliform and E. coli concentrations were greater in the St. Croix River near Woodland Corner, Wisconsin, and at Marine on St. Croix, Minnesota than at other locations sampled. There were no consistent short-term variations in fecal coliform or E. coli concentrations during the summer period or any significant relations between concentrations and stream discharge, based on these results.

  18. Antibiotic resistance and virulence genes in coliform water isolates.

    PubMed

    Stange, C; Sidhu, J P S; Tiehm, A; Toze, S

    2016-11-01

    Widespread fecal pollution of surface water may present a major health risk and a significant pathway for dissemination of antibiotic resistance bacteria. The River Rhine is one of the longest and most important rivers in Europe and an important raw water source for drinking water production. A total of 100 coliform isolates obtained from River Rhine (Germany) were examined for their susceptibility to seven antimicrobial agents. Resistances against amoxicillin, trimethoprim/sulfamethoxazole and tetracycline were detected in 48%, 11% and 9% of isolates respectively. The antibiotic resistance could be traced back to the resistance genes bla TEM , bla SHV , ampC, sul1, sul2, dfrA1, tet(A) and tet(B). Whereby, the ampC gene represents a special case, because its presence is not inevitably linked to a phenotypic antibiotic resistance. Multiple antibiotics resistance was often accompanied by the occurrence of class 1 or 2 integrons. E. coli isolates belonging to phylogenetic groups A and B1 (commensal) were more predominant (57%) compared to B2 and D groups (43%) which are known to carry virulent genes. Additionally, six E. coli virulence genes were also detected. However, the prevalence of virulence genes in the E. coli isolates was low (not exceeding 4.3% per gene) and no diarrheagenic E. coli pathotypes were detected. This study demonstrates that surface water is an important reservoir of ARGs for a number of antibiotic classes such as sulfonamide, trimethoprim, beta-lactam-antibiotics and tetracycline. The occurrence of antibiotic resistance in coliform bacteria isolated from River Rhine provides evidence for the need to develop management strategies to limit the spread of antibiotic resistant bacteria in aquatic environment. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. Water quality and sources of fecal coliform bacteria in the Meduxnekeag River, Houlton, Maine

    USGS Publications Warehouse

    Culbertson, Charles W.; Huntington, Thomas G.; Stoeckel, Donald M.; Caldwell, James M.; O'Donnell, Cara

    2014-01-01

    In response to bacterial contamination in the Meduxnekeag River and the desire to manage the watershed to reduce contaminant sources, the Houlton Band of Maliseet Indians (HBMI) and the U.S. Geological Survey began a cooperative effort to establish a baseline of water-quality data that can be used in future studies and to indicate potential sources of nutrient and bacterial contamination. This study was conducted during the summer of 2005 in the Meduxnekeag River Basin near Houlton, Maine. Continuously recorded specific conductance can be a good indicator for water quality. Specific conductance increased downstream from the town of Houlton, between runoff events, and decreased sharply following major runoff events. Collections of discrete samples during the summer of 2005 indicated seasonal positive concentration-discharge relations for total phosphorus and total nitrogen; these results indicate that storm runoff may mobilize and transport these nutrients from the terrestrial environment to the river. Data collected by the HBMI on fecal coliform bacteria indicated that bacterial contamination enters the Meduxnekeag River from multiple paths including tributaries and surface drains (ditches) in developed areas in Houlton, Maine. The Houlton wastewater treatment discharge was not an important source of bacterial contamination. Bacteroidales-based tests for general fecal contamination (Bac32 marker) were predominantly positive in samples that had excessive fecal contamination as indicated by Enterococci density greater than 104 colony-forming units per 100 millilters. Of the 22 samples tested for Bacteroidales-based markers of human-associated fecal contamination (HF134 and HF183), 8 were positive. Of the 22 samples tested for Bacteroidales-based markers of ruminant-associated fecal contamination (CF128 and CF193), 7 were positive. Human fecal contamination was detected consistently at two sites (surface drains in urban areas in the town of Houlton) and occasionally

  20. Response of coliform populations in streambed sediment and water column to changes in nutrient concentrations in water.

    PubMed

    Shelton, D R; Pachepsky, Y A; Kiefer, L A; Blaustein, R A; McCarty, G W; Dao, T H

    2014-08-01

    As sediments increasingly become recognized as reservoirs of indicator and pathogen microorganisms, an understanding of the persistence of indicator organisms becomes important for assessment and predictions of microbial water quality. The objective of this work was to observe the response of water column and sediment coliform populations to the change in nutrient concentrations in the water column. Survival experiments were conducted in flow-through chambers containing sandy sediments. Bovine feces were collected fresh and introduced into sediment. Sixteen days later, the same fecal material was autoclaved and diluted to provide three levels - 1×, 0.5×, and 0.1× of nutrient concentrations - spike in water column. Total coliforms, Escherichia coli, and total aerobic heterotrophic bacterial concentrations were monitored in water and sediment. Bacteria responded to the nutrient spike with initial growth both in the water column and in sediment. The response of bacterial concentrations in water column was nonlinear, with no significant changes at 0.1 and .5× spikes, but a substantial change at 1× spike. Bacteria in sediment responded to the spikes at all added nutrient levels. Coliform inactivation rates both in sediment and in water after the initial growth occurred, were not significantly different from the inactivation rates before spike. These results indicate that introduction of nutrients into the water column results in nonlinear response of E. coli concentrations both in water and in sediments, followed by the inactivation with the same rate as before introduction of nutrients. Published by Elsevier Ltd.

  1. Bacterial flora analysis of coliforms in sewage, river water, and ground water using MALDI-TOF mass spectrometry.

    PubMed

    Suzuki, Yoshihiro; Niina, Kouki; Matsuwaki, Tomonori; Nukazawa, Kei; Iguchi, Atsushi

    2018-01-28

    The aim of this study was to rapidly and effectively analyze coliforms, which are the most fundamental indicators of water quality for fecal pollution, using matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Coliform bacteria were isolated from municipal sewage, river water, and groundwater. For each sample, 100 isolates were determined by MALDI-TOF MS. In addition, these same 100 isolates were also identified via 16S rRNA gene sequence analysis. Obtained MALDI-TOF MS data were compared with the 16S rRNA sequencing analysis, and the validity of MALDI-TOF MS for classification of coliform bacteria was examined. The concordance rate of bacterial identification for the 100 isolates obtained by MALDI-TOF MS analysis and 16S rRNA gene sequence analysis for sewage, river water, and ground water were 96%, 74%, and 62% at the genus level, respectively. Among the sewage, river water, and ground water samples, the coliform bacterial flora were distinct. The dominant genus of coliforms in sewage, river water, and groundwater were Klebsiella spp., Enterobacter spp., and Serratia spp., respectively. We determined that MALDI-TOF MS is a rapid and accurate tool that can be used to identify coliforms. Therefore, without using conventional 16S rRNA sequencing, it is possible to rapidly and effectively classify coliforms in water using MALDI-TOF MS.

  2. 33 CFR 159.126 - Coliform test: Type II devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... follows: During each of the 10 test days, one sample must be taken at the beginning, middle and end of an 8-consecutive hour period with one additional sample taken immediately following the peak capacity...: Type II devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  3. 33 CFR 159.123 - Coliform test: Type I devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... as follows: During each of the 10-test days, one sample must be taken at the beginning, middle, and end of an 8-consecutive hour period with one additional sample taken immediately following the peak...: Type I devices. (a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent...

  4. Inactivation of bacteria from contaminated streams in Limpopo, South Africa by silver- or copper-nanoparticle paper filters

    PubMed Central

    Dankovich, Theresa A.; Levine, Jonathan S.; Potgieter, Natasha; Dillingham, Rebecca; Smith, James A.

    2016-01-01

    There is an urgent need for inexpensive point-of-use methods to purify drinking water in developing countries to reduce the incidence of illnesses caused by waterborne pathogens. Previously, our work showed the deactivation of laboratory-cultured bacteria by percolation through a thick paper sheet containing either silver (Ag) or copper (Cu) nanoparticles (NP). In this study, these paper filters containing AgNPs or CuNPs have been tested with water sourced from contaminated streams in Limpopo, South Africa. Following the percolation of the contaminated stream water through the metal nanoparticle (MNP) papers, the water quality of the filtered effluent was evaluated with respect to the colony counts of total coliform and E. coli bacteria, turbidity, and either silver or copper ions. Influent total coliform bacteria concentrations from the stream water in Limpopo ranged from 250 CFU/100 mL to 1,750,000 CFU/100 mL. With the less contaminated stream water (250 - 15,000 CFU/100 mL), both AgNP and CuNP papers showed complete inactivation of the coliform bacteria. With the surface water with higher coliform bacteria levels (500,000 - 1,000,000 CFU/100 mL), both the AgNP and CuNP papers showed similar results with a slightly higher bacteria reduction of log10 5.1 for the AgNP papers than the log10 4.8 reduction for the CuNP papers. E. coli results followed similar trends. For most water purification experiments, the metal release from the sheets was minimal, with values under 0.1 ppm for Ag and 1.0 ppm for Cu (the current US EPA and WHO drinking water limits for Ag and Cu, respectively). These results show good potential for the use of paper embedded with silver and/or copper nanoparticles as effective point-of-use water purifiers. PMID:27022474

  5. Fecal-indicator bacteria in surface waters of the Santee River Basin and coastal drainages, North and South Carolina, 1995-98

    USGS Publications Warehouse

    Wilhelm, Lance J.; Maluk, Terry L.

    1998-01-01

    IntroductionHigh levels of fecal-indicator bacteria in rivers and streams can indicate the possible presence of pathogenic (disease-causing) microorganisms. Cholera, typhoid fever, bacterial dysentery, infectious hepatitis, and cryptosporidiosis are some of the well known waterborne diseases that spread through water contaminated and fecal matter. Eye, ear, nose, and throat infections also can result from contact with contaminated water. In general, methods are not routinely used to detect pathogens in water. Instead, bacteria such as total coliforms, fecal coliforms, fecal streptococci, Escherichia coli (E coli), and enterococci are used as indicators of sanitary water quality, because they are present in high numbers in fecal material and have been shown to be associated with some waterborne disease-causing organisms. Indicator bacteria usually are harmless, more plentiful, and easier to detect than pathogens. The concentration of bacteria in a sample of water is usually expressed as the number of bacterial colonies per 100 milliliters of water sample.As part of the U.S. Geological Survey National Water-Quality Assessment Program, 145 samples were collected and analyzed for selected water-quality constituents, fecal coliforms, and fecal streptococci at 17 sites in North and South Carolina from October 1995 through September 1996. Of the original 17 sites, 4 in South Carolina were sampled for E. coli and total coliforms from April through September 1997. At two sites, this sampling continued from October 1997 through April 1998.

  6. Coliform non-compliance nightmares in water-supply distribution systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geldreich, E.E.

    1988-01-01

    Coliform occurrences in distribution systems have created a great concern for both utilities and water authorities because of the implied public-health implications and failure to meet Federal regulations. Many of the known cases involve systems in the east and midwest. The common denominator being systems that have significant amounts of pipe networks over 75 years old and all are treating surface waters. Origins for these contamination events can be found in source-water fluctuations, failures in treatment-barrier protection, or loss of pipe-network integrity. Once passage into the distribution network has been achieved, some of the coliforms (Klebsiella, Enterobacter, Citrobacter) and othermore » heterotrophic bacteria adapt to the pipe environment, finding protection and nutrient support in pipe sediments. Under conditions of seasonal warm waters (10 degC) and availability of assimilable organics in the pipe sediments and tubercles, colonization grows into biofilms that may slough-off into the water supply, creating a coliform non-compliance problem. Significance of these occurrences and control measures are part of a realistic action plan presented for guidance.« less

  7. Variability in the characterization of total coliforms, fecal coliforms, and escherichia coli in recreational water supplies of North Mississippi, USA

    USDA-ARS?s Scientific Manuscript database

    The fecal coliform, Escherichia coli, is a historical organism for the detection of fecal pollution in water supplies. The presence of E. coli indicates a potential contamination of the water supply by other more hazardous human pathogens. In order to accurately determine the presence and degree o...

  8. Regulatory impact analysis: benefits and costs of proposed surface water treatment rule and total coliform rule

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-09-01

    This report contains an analysis of the costs and benefits of controlling microbial contaminants in drinking water through the promulgation of two regulations: (1) the Surface Water Treatment Rule (SWTR); and (2) the Total Coliform Rule. This regulatory impact analysis (RIA) was prepared in accordance with Executive Order 12291, which requires that the costs and benefits of all major rules be examined and compared. The major topical areas covered in the RIA are as follows: problem definition; market imperfections, the need for federal regulation, and consideration of regulatory alternatives; assessment of total costs; assessment of benefits; regulatory flexibility act andmore » Paperwork Reduction Act analyses; and a summary of costs and benefits.« less

  9. Efficacy of β-mannanase supplementation to corn-soya bean meal-based diets on growth performance, nutrient digestibility, blood urea nitrogen, faecal coliform and lactic acid bacteria and faecal noxious gas emission in growing pigs.

    PubMed

    Upadhaya, Santi Devi; Park, Jae Won; Lee, Jae Hwan; Kim, In Ho

    2016-01-01

    A study was conducted to determine the efficacy of β-mannanase supplementation to a diet based on corn and soya bean meal (SBM) on growth performance, nutrient digestibility, blood urea nitrogen (BUN), faecal coliforms and lactic acid bacteria, and noxious gas emission in growing pigs. A total of 140 pigs [(Landrace × Yorkshire) × Duroc; average body weight 25 ± 3 kg] were randomly allotted to a 2 × 2 factorial arrangement with dietary treatments consisting of hulled or dehulled SBM without or with supplementation of 400 U β-mannanase/kg. During the 6 weeks of experimental feeding, β-mannanase supplementation had no effect on body weight gain, feed intake and gain:feed (G:F) ratio. Compared with dehulled SBM, feeding hulled SBM caused an increased feed intake of pigs in the entire trial (p = 0.05). The G:F ratio was improved in pigs receiving dehulled SBM (p < 0.05). Dietary treatments did not influence the total tract digestibility of dry matter, nitrogen and gross energy. Enzyme supplementation reduced (p < 0.05) the population of faecal coliforms and tended to reduce the NH3 concentration after 24 h of fermentation in a closed box containing faecal slurry. Feeding hulled SBM tended to reduce NH3 emission on days 3 and 5 of fermentation. In conclusion, mannanase supplementation had no influence on growth performance and nutrient digestibility but showed a positive effect on reducing coliform population and tended to reduce NH3 emission. Dehulled SBM increased G:F ratio and hulled SBM tended to reduce NH3 emission.

  10. Comparison of Membrane Filtration and Multiple-Tube Fermentation by the Colilert and Enterolert Methods for Detection of Waterborne Coliform Bacteria, Escherichia coli, and Enterococci Used in Drinking and Bathing Water Quality Monitoring in Southern Sweden

    PubMed Central

    Eckner, Karl F.

    1998-01-01

    A total of 338 water samples, 261 drinking water samples and 77 bathing water samples, obtained for routine testing were analyzed in duplicate by Swedish standard methods using multiple-tube fermentation or membrane filtration and by the Colilert and/or Enterolert methods. Water samples came from a wide variety of sources in southern Sweden (Skåne). The Colilert method was found to be more sensitive than Swedish standard methods for detecting coliform bacteria and of equal sensitivity for detecting Escherichia coli when all drinking water samples were grouped together. Based on these results, Swedac, the Swedish laboratory accreditation body, approved for the first time in Sweden use of the Colilert method at this laboratory for the analysis of all water sources not falling under public water regulations (A-krav). The coliform detection study of bathing water yielded anomalous results due to confirmation difficulties. E. coli detection in bathing water was similar by both the Colilert and Swedish standard methods as was fecal streptococcus and enterococcus detection by both the Enterolert and Swedish standard methods. PMID:9687478

  11. Estimated fecal coliform bacteria concentrations using near real-time continuous water-quality and streamflow data from five stream sites in Chester County, Pennsylvania, 2007–16

    USGS Publications Warehouse

    Senior, Lisa A.

    2017-09-15

    Several streams used for recreational activities, such as fishing, swimming, and boating, in Chester County, Pennsylvania, are known to have periodic elevated concentrations of fecal coliform bacteria, a type of bacteria used to indicate the potential presence of fecally related pathogens that may pose health risks to humans exposed through water contact. The availability of near real-time continuous stream discharge, turbidity, and other water-quality data for some streams in the county presents an opportunity to use surrogates to estimate near real-time concentrations of fecal coliform (FC) bacteria and thus provide some information about associated potential health risks during recreational use of streams.The U.S. Geological Survey (USGS), in cooperation with the Chester County Health Department (CCHD) and the Chester County Water Resources Authority (CCWRA), has collected discrete stream samples for analysis of FC concentrations during March–October annually at or near five gaging stations where near real-time continuous data on stream discharge, turbidity, and water temperature have been collected since 2007 (or since 2012 at 2 of the 5 stations). In 2014, the USGS, in cooperation with the CCWRA and CCHD, began to develop regression equations to estimate FC concentrations using available near real-time continuous data. Regression equations included possible explanatory variables of stream discharge, turbidity, water temperature, and seasonal factors calculated using Julian Day with base-10 logarithmic (log) transformations of selected variables.The regression equations were developed using the data from 2007 to 2015 (101–106 discrete bacteria samples per site) for three gaging stations on Brandywine Creek (West Branch Brandywine Creek at Modena, East Branch Brandywine Creek below Downingtown, and Brandywine Creek at Chadds Ford) and from 2012 to 2015 (37–38 discrete bacteria samples per site) for one station each on French Creek near Phoenixville and

  12. Coliform contamination of a coastal embayment: Sources and transport pathways

    USGS Publications Warehouse

    Weiskel, P.K.; Howes, B.L.; Heufelder, G.R.

    1996-01-01

    Fecal bacterial contamination of nearshore waters has direct economic impacts to coastal communities through the loss of shellfisheries and restrictions of recreational uses. We conducted seasonal measurements of fecal coliform (FC) sources and transport pathways contributing to FC contamination of Buttermilk Bay, a shallow embayment adjacent to Buzzards Bay, MA. Typical of most coastal embayments, there were no direct sewage discharges (i.e., outfalls), and fecal bacteria from human, domestic animal, and wildlife pools entered open waters primarily through direct deposition or after transport through surface waters or groundwaters. Direct fecal coliform inputs to bay waters occurred primarily in winter (December-March) from waterfowl, ~33 x 1012 FC yr-1 or ~67% of the total annual loading. Effects of waterfowl inputs on bay FC densities were mitigated by their seasonality, wide distribution across the bay surface, and the apparent limited dispersal from fecal pellets. On-site disposal of sewage by septic systems was the single largest FC source in the watershed-embayment system, 460 x 1012 FC yr-1, but due to attenuation during subsurface transport only a minute fraction, < 0.006 x 1012 FC yr-1, reached bay waters (<0.01% of annual input to bay). Instead, surface water flows, via storm drains and natural streams under both wet- and dry-weather conditions, contributed the major terrestrial input, 12 x 1012 FC yr-1 (24% of annual input), all from animal sources. Since most of the surface water FC inputs were associated with periodic, short-duration rain events with discharge concentrated in nearshore zones, wet-weather flows were found to have a disproportionately high impact on nearshore FC levels. Elution of FC from shoreline deposits of decaying vegetation (wrack) comprised an additional coliform source. Both laboratory and field experiments suggest significant elution of bacteria from wrack, ~3 x 1012 FC yr-1 on a bay-wide basis (6% of annual input), primarily

  13. Beverages obtained from soda fountain machines in the U.S. contain microorganisms, including coliform bacteria.

    PubMed

    White, Amy S; Godard, Renee D; Belling, Carolyn; Kasza, Victoria; Beach, Rebecca L

    2010-01-31

    Ninety beverages of three types (sugar sodas, diet sodas and water) were obtained from 20 self-service and 10 personnel-dispensed soda fountains, analyzed for microbial contamination, and evaluated with respect to U.S. drinking water regulations. A follow-up study compared the concentration and composition of microbial populations in 27 beverages collected from 9 soda fountain machines in the morning as well as in the afternoon. Ice dispensed from these machines was also examined for microbial contamination. While none of the ice samples exceeded U.S. drinking water standards, coliform bacteria was detected in 48% of the beverages and 20% had a heterotrophic plate count greater than 500cfu/ml. Statistical analyses revealed no difference in levels of microbial contamination between beverage types or between those dispensed from self-service and personnel-dispensed soda fountains. More than 11% of the beverages analyzed contained Escherichia coli and over 17% contained Chryseobacterium meningosepticum. Other opportunistic pathogenic microorganisms isolated from the beverages included species of Klebsiella, Staphylococcus, Stenotrophomonas, Candida, and Serratia. Most of the identified bacteria showed resistance to one or more of the 11 antibiotics tested. These findings suggest that soda fountain machines may harbor persistent communities of potentially pathogenic microorganisms which may contribute to episodic gastric distress in the general population and could pose a more significant health risk to immunocompromised individuals. These findings have important public health implications and signal the need for regulations enforcing hygienic practices associated with these beverage dispensers. Copyright 2009 Elsevier B.V. All rights reserved.

  14. Coliforms removal in full-scale activated sludge plants in India.

    PubMed

    Kazmi, A A; Tyagi, V K; Trivedi, R C; Kumar, Arvind

    2008-05-01

    This paper investigates the removal of coliforms in full-scale activated sludge plants (ASP) operating in northern regions of India. Log2.2 and log2.4 removal were observed for total coliforms (TC) and fecal coliforms (FC), respectively. However, the effluent still contained a significant number of TC and FC which was greater than the permissible limit for unrestricted irrigation as prescribed by WHO. The observations also suggest that extended aeration (EA) process operating under high mixed liquor suspended solids (MLSS) and sludge retention time (SRT) is more efficient in the removal of coliforms. Further attempts have been made to establish the relationship between two key wastewater parameters, i.e. biochemical oxygen demand (BOD) and suspended solids (SS) with respect to fecal and TC. The relationships were observed to be linear with a good coefficient of correlation. The interrelationship of BOD and SS with coliforms manifest that improvement of the microbiological quality of wastewater could be linked with the removal of SS. Therefore, SS can serve as a regulatory tool in lieu of an explicit coliforms standard.

  15. Transport of free and particulate-associated bacteria in karst

    USGS Publications Warehouse

    Mahler, B.J.; Personne, J.-C.; Lods, G.F.; Drogue, C.

    2000-01-01

    Karst aquifers, because of their unique hydrogeologic characteristics, are extremely susceptible to contamination by pathogens. Here we present the results of an investigation of contamination of a karst aquifer by fecal indicator bacteria. Two wells intercepting zones with contrasting effective hydraulic conductivities, as determined by pump test, were monitored both during the dry season and in response to a rain event. Samples were also collected from the adjacent ephemeral surface Stream, which is known to be impacted by an upstream wastewater treatment plant after rainfall. Whole water and suspended sediment samples were analyzed for fecal coliforms and enterococci. During the dry season, pumping over a 2-day period resulted in increases in concentrations of fecal coliforms to greater than 10,000 CFU/100 ml in the high-conductivity well; enterococci and total suspended solids also increased, to a lesser degree. Toward the end of the pumping period, as much as 50% of the fecal coliforms were associated with suspended sediment. Irrigation of an up-gradient pine plantation with primary-treated wastewater is the probable source of the bacterial contamination. Sampling after a rain event revealed the strong influence of water quality of the adjacent Terrieu Creek on the ground water. Bacterial concentrations in the wells showed a rapid response to increased concentrations in the surface water, with fecal coliform concentrations in ground water ultimately reaching 60,000 CFU/100 ml. Up to 100% of the bacteria in the ground water was associated with suspended sediment at various times. The results of this investigation are evidence of the strong influence of surface water on ground water in karst terrain, including that of irrigation water. The large proportion of bacteria associated with particulates in the ground Water has important implications for public health, as bacteria associated with particulates may be more persistent and more difficult to inactivate. The

  16. Occurrence of dissolved solids, nutrients, atrazine, and fecal coliform bacteria during low flow in the Cheney Reservoir watershed, south-central Kansas, 1996

    USGS Publications Warehouse

    Christensen, V.G.; Pope, L.M.

    1997-01-01

    A network of 34 stream sampling sites was established in the 1,005-square-mile Cheney Reservoir watershed, south-central Kansas, to evaluate spatial variability in concentrations of selected water-quality constituents during low flow. Land use in the Cheney Reservoir watershed is almost entirely agricultural, consisting of pasture and cropland. Cheney Reservoir provides 40 to 60 percent of the water needs for the city of Wichita, Kansas. Sampling sites were selected to determine the relative contribution of point and nonpoint sources of water-quality constituents to streams in the watershed and to identify areas of potential water-quality concern. Water-quality constituents of interest included dissolved solids and major ions, nitrogen and phosphorus nutrients, atrazine, and fecal coliform bacteria. Water from the 34 sampling sites was sampled once in June and once in September 1996 during Phase I of a two-phase study to evaluate water-quality constituent concentrations and loading characteristics in selected subbasins within the watershed and into and out of Cheney Reservoir. Information summarized in this report pertains to Phase I and was used in the selection of six long-term monitoring sites for Phase II of the study. The average low-flow constituent concentrations in water collected during Phase I from all sampling sites was 671 milligrams per liter for dissolved solids, 0.09 milligram per liter for dissolved ammonia as nitrogen, 0.85 milligram per liter for dissolved nitrite plus nitrate as nitrogen, 0.19 milligram per liter for total phosphorus, 0.20 microgram per liter for dissolved atrazine, and 543 colonies per 100 milliliters of water for fecal coliform bacteria. Generally, these constituents were of nonpoint-source origin and, with the exception of dissolved solids, probably were related to agricultural activities. Dissolved solids probably occur naturally as the result of the dissolution of rocks and ancient marine sediments containing large salt

  17. Rapid disinfection of E-Coliform contaminated water using WO3 semiconductor catalyst by laser-induced photo-catalytic process.

    PubMed

    Gondal, Mohammed A; Khalil, Amjad

    2008-04-01

    Laser-induced photo-catalysis process using WO(3) semiconductor catalyst was applied for the study of disinfection effectiveness of E-coliform-contaminated water. For this purpose, wastewater polluted with E-coliform bacteria was exposed to 355 nm UV radiations generated by third harmonic of Nd: YAG laser in special glass cell with and without WO(3) catalyst. E-Coliform quantification was performed by direct plating method to obtain the efficiency of each disinfection treatment. The dependence of disinfection process on laser irradiation energy, amount of catalyst and duration of laser irradiation was also investigated. The disinfection with WO(3) was quite efficient inactivating E-coliforms. For inactivation of E-coliforms, less than 8 minutes' laser irradiation was required, so that, the treated water complies with the microbial standards for drinking water. This study opens the possibility of application of this simple method in rural areas of developing countries using solar radiation.

  18. Viral and bacterial contamination in a sedimentary aquifer in Uruguay: evaluation of coliforms as regional indicators of viral contamination.

    NASA Astrophysics Data System (ADS)

    Gamazo, Pablo; Colina, Rodney; Victoria, Matias; Alvareda, Elena; Burutatran, Luciana; Ramos, Julian; Olivera, María; Soler, Joan

    2015-04-01

    In many areas of Uruguay groundwater is the only source of water for human consumption and for industrial-agricultural economic activities. Traditionally considered as a safe source, groundwater is commonly used without any treatment. The Uruguayan law requires bacteriological (fecal) analysis for most water uses, but virological analyses are not mentioned in the legislation. In the Salto district, where groundwater is used for human consumption and for agricultural activities, bacterial contamination has been detected in several wells but no viruses analysis have been performed. The Republic University (UDELAR), with the support of the National Agency for Research and Innovation (ANII), is studying the incidence of virus and fecal bacteria in groundwater on an intensive agriculture area of the Salto district. An initial screening campaign of 44 wells was performed in which, besides total and fecal coliforms, rotavirus and adenovirus were detected. A subgroup of the screening wells (15) where selected for bimonthly sampling during a year. In accordance with literature results, single well data analysis shows that coliform and viral contamination can be considered as independent variables. However, when spatial data is integrated, coliform and viral contamination show linear correlation. In this work we present the survey results, we analyse the temporal incidence of variables like precipitation, temperature and chemical composition in well contamination and we discuss the value of coliforms as global indicator of viral contamination for the Salto aquifer.

  19. Comparison of bacteria populations in clean and recycled sand used for bedding in dairy facilities.

    PubMed

    Kristula, M A; Rogers, W; Hogan, J S; Sabo, M

    2005-12-01

    Bedding samples were collected twice from commercial dairy free-stall facilities that used recycled sand and clean sand in both the summer and winter. Collection began on the day sand was taken from the pile (d 0) and placed in the free stalls, and continued for 5 to 7 additional days. The number of colonies per gram of bedding of gram-negative bacteria, coliforms, Streptococcus spp., and Klebsiella spp. were estimated for each sand sample as well as amounts of dry and organic matter. Clean sand (CS) and recycled sand (RS) had the same bacterial counts when compared at any sampling time. The mean counts of bacterial populations did vary over the course of the study in both CS and RS. There was a significant increase in bacterial counts from d 0 to d 1 for gram-negative bacteria, coliforms, and Streptococcus spp. in both winter and summer. Counts of gram-negative bacteria, coliforms, Klebsiella spp., and Streptococcus spp. did not differ from d 1 to 7 in the winter. Total counts of gram-negative bacteria did not differ from d 1 to 7 in the summer. On d 1 in the summer, coliform counts were lower than at d 5 to 7, and Klebsiella spp. counts were lower than on d 3 to 7. Streptococcus spp. counts were high on d 1 and were constant through d 7 in both winter and summer trials. The number of coliform and Klebsiella spp. in both CS and RS was below the threshold thought to cause mastitis during the sampling times. The number of Streptococcus spp. was high in both CS and RS during the sampling periods. Other management factors need to be identified to decrease the number of Streptococcus spp. in bedding. Recycled sand had a higher organic matter and lower dry matter compared with CS in winter and summer. The results for this study were obtained from multiple herd comparisons, and herd was a significant effect suggesting that different management systems influence the number and types of bacteria in both CS and RS.

  20. Effect of waterfowl (Anas platyrhynchos) on indicator bacteria populations in a recreational lake Madison, Wisconsin.

    PubMed Central

    Standridge, J H; Delfino, J J; Kleppe, L B; Butler, R

    1979-01-01

    A public swimming beach in Madison, wis., experienced intermittent high fecal coliform counts during the late summer and early fall of 1978. Public health officials closed the beach on a number of occasions. A public health survey identified a combination of waterfowl wastes and meteorological events as the explanation for the high bacteria counts. Fecal coliform bacteria were deposited by mallard ducks and multiplied in the beach sands. The bacteria were subsequently transported into the lake and resulted in high fecal coliform counts in the swimming area. PMID:394683

  1. Isolation of Environmental Bacteria from Surface and Drinking Water in Mafikeng, South Africa, and Characterization Using Their Antibiotic Resistance Profiles

    PubMed Central

    Mulamattathil, Suma George; Mbewe, Moses; Ateba, Collins Njie

    2014-01-01

    The aim of this study was to isolate and identify environmental bacteria from various raw water sources as well as the drinking water distributions system in Mafikeng, South Africa, and to determine their antibiotic resistance profiles. Water samples from five different sites (raw and drinking water) were analysed for the presence of faecal indicator bacteria as well as Aeromonas and Pseudomonas species. Faecal and total coliforms were detected in summer in the treated water samples from the Modimola dam and in the mixed water samples, with Pseudomonas spp. being the most prevalent organism. The most prevalent multiple antibiotic resistance phenotype observed was KF-AP-C-E-OT-K-TM-A. All organisms tested were resistant to erythromycin, trimethoprim, and amoxicillin. All isolates were susceptible to ciprofloxacin and faecal coliforms and Pseudomonas spp. to neomycin and streptomycin. Cluster analysis based on inhibition zone diameter data suggests that the isolates had similar chemical exposure histories. Isolates were identified using gyrB, toxA, ecfX, aerA, and hylH gene fragments and gyrB, ecfX, and hylH fragments were amplified. These results demonstrate that (i) the drinking water from Mafikeng contains various bacterial species and at times faecal and total coliforms. (ii) The various bacteria are resistant to various classes of antibiotics. PMID:25105027

  2. Influence of solid dairy manure and compost with and without alum on survival of indicator bacteria in soil and on potato.

    PubMed

    Entry, James A; Leytem, April B; Verwey, Sheryl

    2005-11-01

    We measured Escherichia coli, Enterococcus spp. and fecal coliform numbers in soil and on fresh potato skins after addition of solid dairy manure and dairy compost with and without alum (Al(2)(SO(4))(3)) treatment 1, 7, 14, 28, 179 and 297 days after application. The addition of dairy compost or solid dairy manure at rates to meet crop phosphorus uptake did not consistently increase E. coli and Enterococcus spp. and fecal coliform bacteria in the soil. We did not detect E. coli in any soil sample after the first sampling day. Seven, 14, 28, 179 and 297 days after solid dairy waste and compost and alum were applied to soil, alum did not consistently affect Enterococcus spp. and fecal coliform bacteria in the soil. We did not detect E. coli in any soil, fresh potato skin or potato wash-water at 214 days after dairy manure or compost application regardless of alum treatment. Dairy compost or solid dairy manure application to soil at rates to meet crop phosphorus uptake did not consistently increase Enterococcus spp. and fecal coliform numbers in bulk soil. Solid dairy manure application to soil at rates to meet crop phosphorus uptake, increased Enterococcus spp. and fecal coliform numbers in potato rhizosphere soil. However, fresh potato skins had higher Enterococcus spp. and fecal coliform numbers when solid dairy manure was added to soil compared to compost, N and P inorganic fertilizer and N fertilizer treatments. We did not find any E. coli, Enterococcus or total coliform bacteria on the exterior of the tuber, within the peel or within a whole baked potato after microwave cooking for 5 min.

  3. Comparison of the surface structure, metal binding, and fecal coliform recoveries of nine membrane filters.

    PubMed Central

    Tobin, R S; Dutka, B J

    1977-01-01

    A comparative study was made of nine commonly used membrane filters from five manufacturers, all recommended for enumeration of coliform bacteria. Bacterial recoveries and flow rates were examined from three types of water and were found to correlate with the surface pore structure determined by scanning electron microscopy. The sorption of metals was also determined. The results of these studies indicate that the five best membranes for fecal coliform recovery could be placed in two groups: Millipore HC and Gelman, followed by Johns-Manville SG and AG and Sartorius 13806. Images PMID:329763

  4. Rapid detection of coliforms in drinking water of Arak city using multiplex PCR method in comparison with the standard method of culture (Most Probably Number)

    PubMed Central

    Fatemeh, Dehghan; Reza, Zolfaghari Mohammad; Mohammad, Arjomandzadegan; Salomeh, Kalantari; Reza, Ahmari Gholam; Hossein, Sarmadian; Maryam, Sadrnia; Azam, Ahmadi; Mana, Shojapoor; Negin, Najarian; Reza, Kasravi Alii; Saeed, Falahat

    2014-01-01

    Objective To analyse molecular detection of coliforms and shorten the time of PCR. Methods Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number (MPN) method for 16 artificial and 101 field samples. The molecular method was also conducted on isolated coliforms from positive MPN samples; standard sample for verification of microbial method certificated reference material; isolated strains from certificated reference material and standard bacteria. The PCR and electrophoresis parameters were changed for reducing the operation time. Results Results of PCR for lacZ and uidA genes were similar in all of standard, operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR. PCR results were confirmed by MPN culture method by sensitivity 86% (95% CI: 0.71-0.93). Also the total execution time, with a successful change of factors, was reduced to less than two and a half hour. Conclusions Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city. It's recommended to be used at least as an initial screening test, and then the positive samples could be randomly tested by MPN. PMID:25182727

  5. The efficacy of subsurface flow reed bed treatment in the removal of Campylobacter spp., faecal coliforms and Escherichia coli from poultry litter.

    PubMed

    Duggan, J; Bates, M P; Phillips, C A

    2001-06-01

    The use of poultry waste as a fertiliser on arable land is an accepted method of waste treatment. However, run-off from such practices may result in contamination of the watercourse by human pathogens. In this study the effectiveness of using constructed wetlands as an alternative treatment for poultry manure waste was evaluated. Enumeration of Campylobacter spp., Escherichia coli, total coliforms and total aerobes were carried out on influent and effluent samples from reed beds loaded with poultry waste. For both sequential loading and continuous loading there was a statistically significant mean log reduction of 3.56 and 4.25 for E. coli, 3.2 and 3.88 for coliforms, 3.85 and 4.2 for total aerobic counts and 3.13 and 2.96 for Campylobacter spp., respectively. This method, which has been previously recognised as cost-effective and environmentally acceptable, provides an efficient method for reducing numbers of these bacteria in poultry waste and therefore an effective alternative treatment for such waste or waters containing run off from land previously spread with poultry manure.

  6. EFFECT OF DIETARY ANTIBIOTICS UPON COLIFORM BACTERIA AND LACTOBACILLI IN THE INTESTINAL TRACT OF URIC ACID-FED CHICKS.

    PubMed

    BARE, L N; WISEMAN, R F; ABBOTT, O J

    1964-02-01

    Bare, L. N. (University of Kentucky, Lexington), R. F. Wiseman, and O. J. Abbott. Effect of dietary antibiotics upon coliform bacteria and lactobacilli in the intestinal tract of uric acid-fed chicks. J. Bacteriol. 87:329-331. 1964.-Male chicks (1-day-old; Vantress X Arbor Acre) were fed a basal glucose-soybean oil meal diet, a 2% uric acid-containing diet with and without 5 mg/lb of zinc bacitracin and 20 mg/lb of procaine penicillin G, and one supplemented with the antibiotics only. After 4 weeks, the chicks receiving the uric acid without antibiotics showed a weight depression. The presence of antibiotics in the ration with the uric acid reversed this growth depression. Bacteriological and chemical analyses of the contents of the small intestine revealed an increase in numbers of uricolytic Aerobacter spp. and an increased degradation of uric acid in the tract of the "uric-antibiotic"-fed chicks. The counts of lactobacilli were always lowest in this group of chicks

  7. Removal of enteric bacteria in constructed treatment wetlands with emergent macrophytes: a review.

    PubMed

    Vymazal, Jan

    2005-01-01

    Domestic and municipal sewage contains various pathogenic or potentially pathogenic microorganisms which, depending on species concentration, pose a potential risk to human health and whose presence must therefore be reduced in the course of wastewater treatment. The removal of microbiological pollution is seldom a primary target for constructed treatment wetlands (CWs). However, wetlands are known to act as excellent biofilters through a complex of physical, chemical and biological factors which all participate in the reduction of the number of bacteria. Measurement of human pathogenic organisms in untreated and treated wastewater is expensive and technically challenging. Consequently, environmental engineers have sought indicator organisms that are (1) easy to monitor and (2) correlate with population of pathogenic organisms. The most frequently used indicators are total coliforms, fecal coliforms, fecal streptococci and Escherichia coli. The literature survey of 60 constructed wetlands with emergent vegetation around the world revealed that removal of total and fecal coliforms in constructed wetlands with emergent macrophytes is high, usually 95 to > 99% while removal of fecal streptococci is lower, usually 80-95%. Because bacterial removal efficiency is a function of inflow bacteria number, the high removal effects are achieved for untreated or mechanically pretreated wastewater. Therefore, the outflow numbers of bacteria are more important. For TC and FC the outflow concentrations are usually in the range of 10(2) to 10(5) CFU/ 100 ml while for FS the range is between 10(2) and 10(4) CFU/ 100 ml. Results from operating systems suggest that enteric microbe removal efficiency in CWs with emergent macrophytes is primarily influenced by hydraulic loading rate (HLR) and the resultant hydraulic residence time (HRT) and the presence of vegetation. Removal of enteric bacteria follows approximately a first-order relationship.

  8. 40 CFR 141.21 - Coliform sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... transit. 3 Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the... total coliform, using lactose broth, is less than 10 percent. 4 If inverted tubes are used to detect gas... negative-rates may be based on lactose fermentation, the rapid test for β-galactosidase and cytochrome...

  9. 40 CFR 141.21 - Coliform sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... transit. 3 Lactose broth, as commercially available, may be used in lieu of lauryl tryptose broth, if the... total coliform, using lactose broth, is less than 10 percent. 4 If inverted tubes are used to detect gas... negative-rates may be based on lactose fermentation, the rapid test for β-galactosidase and cytochrome...

  10. Comparison of nine brands of membrane filter and the most-probable-number methods for total coliform enumeration in sewage-contaminated drinking water.

    PubMed Central

    Tobin, R S; Lomax, P; Kushner, D J

    1980-01-01

    Nine different brands of membrane filter were compared in the membrane filtration (MF) method, and those with the highest yields were compared against the most-probable-number (MPN) multiple-tube method for total coliform enumeration in simulated sewage-contaminated tap water. The water was chlorinated for 30 min to subject the organisms to stresses similar to those encountered during treatment and distribution of drinking water. Significant differences were observed among membranes in four of the six experiments, with two- to four-times-higher recoveries between the membranes at each extreme of recovery. When results from the membranes with the highest total coliform recovery rate were compared with the MPN results, the MF results were found significantly higher in one experiment and equivalent to the MPN results in the other five experiments. A comparison was made of the species enumerated by these methods; in general the two methods enumerated a similar spectrum of organisms, with some indication that the MF method was subject to greater interference by Aeromonas. PMID:7469407

  11. Bacteria associated with granular activated carbon particles in drinking water.

    PubMed Central

    Camper, A K; LeChevallier, M W; Broadaway, S C; McFeters, G A

    1986-01-01

    A sampling protocol was developed to examine particles released from granular activated carbon filter beds. A gauze filter/Swinnex procedure was used to collect carbon fines from 201 granular activated carbon-treated drinking water samples over 12 months. Application of a homogenization procedure (developed previously) indicated that 41.4% of the water samples had heterotrophic plate count bacteria attached to carbon particles. With the enumeration procedures described, heterotrophic plate count bacteria were recovered at an average rate of 8.6 times higher than by conventional analyses. Over 17% of the samples contained carbon particles colonized with coliform bacteria as enumerated with modified most-probable-number and membrane filter techniques. In some instances coliform recoveries were 122 to 1,194 times higher than by standard procedures. Nearly 28% of the coliforms attached to these particles in drinking water exhibited the fecal biotype. Scanning electron micrographs of carbon fines from treated drinking water showed microcolonies of bacteria on particle surfaces. These data indicate that bacteria attached to carbon fines may be an important mechanism by which microorganisms penetrate treatment barriers and enter potable water supplies. PMID:3767356

  12. Transport of free and particulate-associated bacteria in karst

    NASA Astrophysics Data System (ADS)

    Mahler, B. J.; Personné, J.-C.; Lods, G. F.; Drogue, C.

    2000-12-01

    Karst aquifers, because of their unique hydrogeologic characteristics, are extremely susceptible to contamination by pathogens. Here we present the results of an investigation of contamination of a karst aquifer by fecal indicator bacteria. Two wells intercepting zones with contrasting effective hydraulic conductivities, as determined by pump test, were monitored both during the dry season and in response to a rain event. Samples were also collected from the adjacent ephemeral surface stream, which is known to be impacted by an upstream wastewater treatment plant after rainfall. Whole water and suspended sediment samples were analyzed for fecal coliforms and enterococci. During the dry season, pumping over a 2-day period resulted in increases in concentrations of fecal coliforms to greater than 10,000 CFU/100 ml in the high-conductivity well; enterococci and total suspended solids also increased, to a lesser degree. Toward the end of the pumping period, as much as 50% of the fecal coliforms were associated with suspended sediment. Irrigation of an up-gradient pine plantation with primary-treated wastewater is the probable source of the bacterial contamination. Sampling after a rain event revealed the strong influence of water quality of the adjacent Terrieu Creek on the ground water. Bacterial concentrations in the wells showed a rapid response to increased concentrations in the surface water, with fecal coliform concentrations in ground water ultimately reaching 60,000 CFU/100 ml. Up to 100% of the bacteria in the ground water was associated with suspended sediment at various times. The results of this investigation are evidence of the strong influence of surface water on ground water in karst terrain, including that of irrigation water. The large proportion of bacteria associated with particulates in the ground water has important implications for public health, as bacteria associated with particulates may be more persistent and more difficult to inactivate. The

  13. Effects of combined sewer overflow and stormwater on indicator bacteria concentrations in the Tama River due to the high population density of Tokyo Metropolitan area.

    PubMed

    Ham, Young-Sik; Kobori, Hiromi; Takasago, Masahisa

    2009-05-01

    The indicator bacteria (standard plate count, total coliform, and fecal coliform bacteria) concentrations have been investigated using six ambient habitats (population density, percent sewer penetration, stream flow rate (m(3)/sec), percent residential area, percent forest area and percent agricultural area) in the Tama River basin in Tokyo, Japan during June 2003 to January 2005. The downstream and tributary Tama River showed higher concentrations of TC and FC bacteria than the upstream waters, which exceeded an environmental quality standard for rivers and a bathing water quality criterion. It was estimated that combined sewer overflow (CSO) and stormwater effluents contributed -4-23% to the indicator bacteria concentrations of the Tama River. The results of multiple regression analyses show that the indicator bacteria concentrations of Tama River basin are significantly affected by population density. It is concluded that the Tama River received a significant bacterial contamination load originating from the anthropogenic source.

  14. MinION Nanopore Sequencing Enables Correlation between Resistome Phenotype and Genotype of Coliform Bacteria in Municipal Sewage.

    PubMed

    Xia, Yu; Li, An-Dong; Deng, Yu; Jiang, Xiao-Tao; Li, Li-Guan; Zhang, Tong

    2017-01-01

    Wastewater treatment plants (WWTPs) functioned as the intersection between the human society and nature environment, are receiving increasingly more attention on risk assessment of the acquisition of environmental antibiotic resistance genes (ARGs) by pathogenetic populations during treatment. However, because of the general lack of robust resistome profiling methods, genotype, and resistance phenotype is still poorly correlated in human pathogens of sewage samples. Here we applied MinION sequencing to quantify the resistance genes of multiple antibiotic resistant (MAR) coliform bacteria, a common indicator for human enteric pathogens in sewage samples. Our pipeline could deliver the results within 30 h from sample collection and the resistome quantification was consistent to that based on the Illumina platform. Additionally, the long nanopore reads not only enabled a simultaneous identification of the carrier populations of ARGs detected, but also facilitated the genome reconstruction of a representative MAR strain, from which we identified an instance of chromosomal integration of environmental resistance gene obtained by plasmid exchange with a porcine pathogen. This study demonstrated the utilization of MinION sequencing in quick monitoring and simultaneous phylogenetic tracking of environmental ARGs to address potential health risk associated with them.

  15. MinION Nanopore Sequencing Enables Correlation between Resistome Phenotype and Genotype of Coliform Bacteria in Municipal Sewage

    PubMed Central

    Xia, Yu; Li, An-Dong; Deng, Yu; Jiang, Xiao-Tao; Li, Li-Guan; Zhang, Tong

    2017-01-01

    Wastewater treatment plants (WWTPs) functioned as the intersection between the human society and nature environment, are receiving increasingly more attention on risk assessment of the acquisition of environmental antibiotic resistance genes (ARGs) by pathogenetic populations during treatment. However, because of the general lack of robust resistome profiling methods, genotype, and resistance phenotype is still poorly correlated in human pathogens of sewage samples. Here we applied MinION sequencing to quantify the resistance genes of multiple antibiotic resistant (MAR) coliform bacteria, a common indicator for human enteric pathogens in sewage samples. Our pipeline could deliver the results within 30 h from sample collection and the resistome quantification was consistent to that based on the Illumina platform. Additionally, the long nanopore reads not only enabled a simultaneous identification of the carrier populations of ARGs detected, but also facilitated the genome reconstruction of a representative MAR strain, from which we identified an instance of chromosomal integration of environmental resistance gene obtained by plasmid exchange with a porcine pathogen. This study demonstrated the utilization of MinION sequencing in quick monitoring and simultaneous phylogenetic tracking of environmental ARGs to address potential health risk associated with them. PMID:29163399

  16. Relatively high antibiotic resistance among heterotrophic bacteria from arctic fjord sediments than water - Evidence towards better selection pressure in the fjord sediments

    NASA Astrophysics Data System (ADS)

    Hatha, A. A. Mohamed; Neethu, C. S.; Nikhil, S. M.; Rahiman, K. M. Mujeeb; Krishnan, K. P.; Saramma, A. V.

    2015-12-01

    The objective of this study was to determine the prevalence of antibiotic resistance among aerobic heterotrophic bacteria and coliform bacteria from water and sediment of Kongsfjord. The study was based on the assumption that arctic fjord environments are relatively pristine and offer very little selection pressure for drug resistant mutants. In order to test the hypothesis, 200 isolates belonging to aerobic heterotrophic bacteria and 114 isolates belonging to coliforms were tested against 15 antibiotics belonging to 5 different classes such as beta lactams, aminoglycosides, quinolones, sulpha drugs and tetracyclines. Resistance to beta lactam and extended spectrum beta lactam (ESBL) antibiotics was considerably high and they found to vary significantly (p < 0.05) between heterotrophic and coliform bacteria. Though the coliforms showed significantly high level of antibiotic resistance against ESBL's extent and diversity of antibiotic resistance (as revealed by multiple antibiotic resistance index and resistance patterns), was high in the aerobic heterotrophic bacteria. Most striking observation was that isolates from fjord sediments (both heterotrophic bacteria and coliforms) in general showed relatively high prevalence of antibiotic resistance against most of the antibiotics tested, indicating to better selection pressure for drug resistance mutants in the fjord sediments.

  17. Evidence for the role of copper in the injury process of coliform bacteria in drinking water. [Escherichia coli

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domek, M.J.; LeChevallier, M.W.; Cameron, S.C.

    1984-08-01

    Low levels of copper in chlorine-free distribution water caused injury of coliform populations. Monitoring of 44 drinking water samples indicated that 64% of the coliform population was injured. Physical and chemical parameters were measured, including three heavy metals (Cu, Cd, and Pb). Copper concentrations were important, ranging from 0.007 to 0.54 mg/liter. Statistical analyses of these factors were used to develop a model to predict coliform injury. The model predicted almost 90% injury with a copper concentration near the mean observed value (0.158 mg/liter) in distribution waters. Laboratory studies with copper concentrations of 0.025 and 0.050 mg/liter in an inorganicmore » carbon buffer under controlled conditions of temperature and pH caused over 90% injury within 6 and 2 days, respectively. Studies of the metabolism of injured Escherichia coli cells indicated that the respiratory chain is at least one site of damage in injured cells.« less

  18. Total coliform and E. coli in public water systems using undisinfected ground water in the United States.

    PubMed

    Messner, Michael J; Berger, Philip; Javier, Julie

    2017-06-01

    Public water systems (PWSs) in the United States generate total coliform (TC) and Escherichia coli (EC) monitoring data, as required by the Total Coliform Rule (TCR). We analyzed data generated in 2011 by approximately 38,000 small (serving fewer than 4101 individuals) undisinfected public water systems (PWSs). We used statistical modeling to characterize a distribution of TC detection probabilities for each of nine groupings of PWSs based on system type (community, non-transient non-community, and transient non-community) and population served (less than 101, 101-1000 and 1001-4100 people). We found that among PWS types sampled in 2011, on average, undisinfected transient PWSs test positive for TC 4.3% of the time as compared with 3% for undisinfected non-transient PWSs and 2.5% for undisinfected community PWSs. Within each type of PWS, the smaller systems have higher median TC detection than the larger systems. All TC-positive samples were assayed for EC. Among TC-positive samples from small undisinfected PWSs, EC is detected in about 5% of samples, regardless of PWS type or size. We evaluated the upper tail of the TC detection probability distributions and found that significant percentages of some system types have high TC detection probabilities. For example, assuming the systems providing data are nationally-representative, then 5.0% of the ∼50,000 small undisinfected transient PWSs in the U.S. have TC detection probabilities of 20% or more. Communities with such high TC detection probabilities may have elevated risk of acute gastrointestinal (AGI) illness - perhaps as great or greater than the attributable risk to drinking water (6-22%) calculated for 14 Wisconsin community PWSs with much lower TC detection probabilities (about 2.3%, Borchardt et al., 2012). Published by Elsevier GmbH.

  19. 40 CFR 412.2 - General definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....23. (c) Fecal coliform means the bacterial count (Parameter 1) at 40 CFR 136.3 in Table 1A, which... Table 1A at 40 CFR 136.3 are defined as follows: (1) Fecal coliform means fecal coliform bacteria. (2) Total coliform means all coliform bacteria. ...

  20. NEW MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA COLI IN WATER (PUBLISHED ERRATUM APPEARS IN APP ENVIRON MICROBIOL 1993 DEC;59(12):4378)

    EPA Science Inventory

    A new membrane filter agar medium (MI agar) containing a chromogen, indoxyl-beta-D-glucuronide, and a fluorogen, 4-methylumbelliferyl-beta-D-galactopyranoside, was developed to simultaneously detect and enumerate Escherichia coli and total coliforms (TC) in water samples on the b...

  1. Comparative evaluation of chromogenic agar CM1046 and mFC agar for detection of E. coli and thermotolerant coliform bacteria from water samples.

    PubMed

    Wohlsen, T D

    2011-08-01

    The equivalence of Oxoid (CM 1046) Brilliance((TM)) E. coli/coliform selective agar to mFC agar, as used in the Australian/New Zealand Standard Method to detect thermotolerant coliforms and Escherichia coli in water samples, was assessed. A total of 244 water samples were analysed in parallel over a 5-month period. Sewage effluent samples (n = 131, sites = 43), freshwater (n = 62, sites = 18) and marine/brackish water samples (n = 51, sites = 23) were analysed. The Wilcoxon matched-pairs signed-ranks test showed a varying degree of statistical difference between the two methods. All matrices had a higher recovery in the trial method. Enterococci faecalis, Aeromonas spp. and Vibrio spp. did not grow on the CM1046 agar, and Pseudomonas aeruginosa and Enterobacter aerogenes were inhibited. The use of CM 1046 for the detection and enumeration of E. coli and thermotolerant coliforms in water samples is a suitable alternative to the AS/NZS Standard Method. The use of CM1046 agar was less labour intensive and time consuming, as no secondary confirmation steps were required. Confirmed results could be reported within 24 h of sample analysis, as compared to 48 h with the reference method. Public health concerns can be addressed in a more efficient manner. © 2011 Unitywater. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  2. Microbiome of Total Versus Live Bacteria in the Gut of Rex Rabbits

    PubMed Central

    Fu, Xiangchao; Zeng, Bo; Wang, Ping; Wang, Lihuan; Wen, Bin; Li, Ying; Liu, Hanzhong; Bai, Shiqie; Jia, Gang

    2018-01-01

    Gastrointestinal bacteria are essential for host health, and only viable microorganisms contribute to gastrointestinal functions. When evaluating the gut microbiota by next generation sequencing method, dead bacteria, which compose a proportion of gut bacteria, may distort analysis of the live gut microbiota. We collected stomach, jejunum, ileum, cecum, and colon contents from Rex rabbits. A modified propidium monoazide (PMA) treatment protocol was used to exclude DNA from dead bacteria. Analysis of untreated samples yielded total bacteria, and analysis of PMA-treated samples yielded live bacteria. Quantitative polymerase chain reaction and 16S rRNA gene sequencing were performed to evaluate the live-to-total bacteria ratio and compare the difference between live and total microbiota in the entire digestive tract. A low proportion of live bacteria in the foregut (stomach 1.12%, jejunum 1.2%, ileum 2.84%) and a high proportion of live bacteria in the hindgut (cecum 24.66%, colon 19.08%) were observed. A significant difference existed between total and live microbiota. Clostridiales, Ruminococcaceae, and S24-7 dominated the hindgut of both groups, while Acinetobacter and Cupriavidus dominated only in live foregut microbiota. Clostridiales and Ruminococcaceae abundance decreased, while S24-7 increased in live hindgut microbiota. The alpha- and beta-diversities differed significantly between groups. Analysis of networks showed the mutual relationship between live bacteria differed vastly when compared with total bacteria. Our study revealed a large number of dead bacteria existed in the digestive tract of Rex rabbits and distorted the community profile of the live microbiota. Total bacteria is an improper representation of the live gut microbiota, particularly in the foregut. PMID:29692775

  3. 75 FR 53267 - National Primary Drinking Water Regulations: Revisions to the Total Coliform Rule; Extension of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-31

    .... The proposed revisions require systems that have an indication of coliform contamination in the... deaths due to potential fecal contamination and waterborne pathogen exposure. This proposal also...

  4. Effect of different oral oxytetracycline treatment regimes on selection of antimicrobial resistant coliforms in nursery pigs.

    PubMed

    Herrero-Fresno, Ana; Zachariasen, Camilla; Nørholm, Nanna; Holm, Anders; Christiansen, Lasse Engbo; Olsen, John Elmerdahl

    2017-09-01

    A major concern derived from using antimicrobials in pig production is the development of resistance. This study aimed to assess the impact of selected combinations of oral dose and duration of treatment with oxytetracycline (OTC) on selection of tetracycline resistant (TET-R) coliforms recovered from swine feces. The work encompassed two studies: 1) OTC 5mg/kg and 20mg/kg were administered to nursery pigs for 3 and 10days, respectively, under controlled experimental conditions, and 2) 10mg/kg, 20mg/kg and 30mg/kg OTC were given to a higher number of pigs for 6, 3 and 2days, respectively, under field conditions. Statistical modeling was applied to analyze trends in the proportion of TET-R coliforms. In the experimental study, no statistical difference in proportion of TET-R coliforms was observed between treatments at the end of the trial (day 18) and compared to day 0. In the field study, treatment had a significant effect on the proportion of TET-R bacteria two days after the end of treatment (2dAT) with the regimes "low dose-six days" and "medium dose-three days" yielding the highest and lowest proportions of TET-R strains, respectively. No indication of co-selection for ampicillin- and sulphonamide -R bacteria was observed for any treatment at 2dAT. By the end of the nursery period, the proportion of TET-R bacteria was not significantly different between treatments and compared to day 0. Our results suggest that similar resistance levels might be obtained by using different treatment regimes regardless of the combinations of oral dose-duration of treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Evaluation of standard and modified M-FC, MacConkey, and Teepol media for membrane filtration counting of fecal coliforms in water.

    PubMed

    Grabow, W O; Hilner, C A; Coubrough, P

    1981-08-01

    MacConkey agar, standard M-FC agar, M-FC agar without rosolic acid, M-FC agar with a resuscitation top layer, Teepol agar, and pads saturated with Teepol broth, were evaluated as growth media for membrane filtration counting of fecal coliform bacteria in water. In comparative tests on 312 samples of water from a wide variety of sources, including chlorinated effluents, M-FC agar without rosolic acid proved the medium of choice because it generally yielded the highest counts, was readily obtainable, easy to prepare and handle, and yielded clearly recognizable fecal coliform colonies. Identification of 1,139 fecal coliform isolates showed that fecal coliform tests cannot be used to enumerate Escherichia coli because the incidence of E. coli among fecal coliforms varied from an average of 51% for river water to 93% for an activated sludge effluent after chlorination. The incidence of Klebsiella pneumoniae among fecal coliforms varied from an average of 4% for the activated sludge effluent after chlorination to 32% for the river water. The advantages of a standard membrane filtration procedure for routine counting of fecal coliforms in water using M-FC agar without rosolic acid as growth medium, in the absence of preincubation or resuscitation steps, are outlined.

  6. Effect of ambient temperature storage on potable water coliform population estimations.

    PubMed Central

    Standridge, J H; Delfino, J J

    1983-01-01

    The effect of the length of time between sampling potable water and performing coliform analyses has been a long-standing controversial issue in environmental microbiology. The issue is of practical importance since reducing the sample-to-analysis time may substantially increase costs for water analysis programs. Randomly selected samples (from those routinely collected throughout the State of Wisconsin) were analyzed for total coliforms after being held at room temperature (20 +/- 2 degrees C) for 24 and 48 h. Differences in results for the two holding times were compared with differences predicted by probability calculations. The study showed that storage of the potable water for up to 48 h had little effect on the public health significance of most samples containing more than two coliforms per 100 ml. PMID:6651296

  7. Effect of air pollution on the total bacteria and pathogenic bacteria in different sizes of particulate matter.

    PubMed

    Liu, Huan; Zhang, Xu; Zhang, Hao; Yao, Xiangwu; Zhou, Meng; Wang, Jiaqi; He, Zhanfei; Zhang, Huihui; Lou, Liping; Mao, Weihua; Zheng, Ping; Hu, Baolan

    2018-02-01

    In recent years, air pollution events have occurred frequently in China during the winter. Most studies have focused on the physical and chemical composition of polluted air. Some studies have examined the bacterial bioaerosols both indoors and outdoors. But few studies have focused on the relationship between air pollution and bacteria, especially pathogenic bacteria. Airborne PM samples with different diameters and different air quality index values were collected in Hangzhou, China from December 2014 to January 2015. High-throughput sequencing of 16S rRNA was used to categorize the airborne bacteria. Based on the NCBI database, the "Human Pathogen Database" was established, which is related to human health. Among all the PM samples, the diversity and concentration of total bacteria were lowest in the moderately or heavily polluted air. However, in the PM2.5 and PM10 samples, the relative abundances of pathogenic bacteria were highest in the heavily and moderately polluted air respectively. Considering the PM samples with different particle sizes, the diversities of total bacteria and the proportion of pathogenic bacteria in the PM10 samples were different from those in the PM2.5 and TSP samples. The composition of PM samples with different sizes range may be responsible for the variances. The relative humidity, carbon monoxide and ozone concentrations were the main factors, which affected the diversity of total bacteria and the proportion of pathogenic bacteria. Among the different environmental samples, the compositions of the total bacteria were very similar in all the airborne PM samples, but different from those in the water, surface soil, and ground dust samples. Which may be attributed to that the long-distance transport of the airflow may influence the composition of the airborne bacteria. This study of the pathogenic bacteria in airborne PM samples can provide a reference for environmental and public health researchers. Copyright © 2017 Elsevier Ltd

  8. Survival of pathogenic bacteria in compost with special reference to Escherichia coli.

    PubMed

    Gong, Chun-ming; Koichi, Inoue; Shunji, Inanaga; Takashi, Someya

    2005-01-01

    Application of compost in agricultural practice could potentially cause contamination of foodstuffs with pathogenic bacteria such as Escherichia coli O157:H7 (E. Coli O157). We investigated pathogenic bacteria in compost collected from the compost facilities, and evaluated the survival of E. coli K12 and O157 in laboratory experiments. Out of 19 compost product samples, coliform bacteria and salmonella were detected in 7 and 3 samples respectively. The number of coliform bacteria was 1.8 x 10(2) to 2.5 x 10(6) CFU/g dw and that of salmonella was 4.2 x 10(1) to 6.0 x 10(3) CFU/g dw. Moreover, coliform bacteria, fecal coliform, E. coli and salmonella were detected during composting at 54 degrees C to 67 degrees C. The results indicated that moisture content was a very important factor to the heat sensitivity of pathogenic bacteria in compost, E. coil in compost of high moisture content was more sensitive than that in compost of low moisture content, cells harvested in logarithmic phase was more sensitive than these in stationary phase, and E. coli K12 was more sensitive than E. coli O157. Based on the D values, the lethal time of E. coli K12 and O157 from l0(8) to 10(0) CFU/g dw were 16.3 and 28.8 min, respectively, at 60 degrees C in compost with 40% moisture content. However, some E. coil cells survived in composting process at 54 degrees C to 67 degrees C. Water potential (low moisture content) and physiological aspects of bacteria (stationary phase) could explain only in part of the prolonged survival of E. coil in compost, and there should be some other factors that are conducive to bacterial survival in compost.

  9. A MECHANISTIC MODEL OF RUNOFF-ASSOCIATED FECAL COLIFORM FATE AND TRANSPORT THROUGH A COASTAL LAGOON. (R828676C003)

    EPA Science Inventory

    Fecal coliform (FC) contamination in coastal waters is an ongoing public health problem worldwide. Coastal wetlands and lagoons are typically expected to protect coastal waters by attenuating watershed pollutants including FC bacteria. However, new evidence suggests that coast...

  10. Holding effects on coliform enumeration in drinking water samples.

    PubMed Central

    McDaniels, A E; Bordner, R H; Gartside, P S; Haines, J R; Brenner, K P; Rankin, C C

    1985-01-01

    Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4083877

  11. Antibacterial Activities of Jatropha curcas (LINN) on Coliforms Isolated from Surface Waters in Akure, Nigeria

    PubMed Central

    Dada, E. O.; Ekundayo, F. O.; Makanjuola, O. O.

    2014-01-01

    This study investigated the antibacterial activities of hot water, ethanol and acetone extracts of Jatropha curcas (LINN) leaves on coliforms isolated from surface waters using growth inhibition indices based on agar plate technique. The percentage recovery of the extracts was 19.17%, 18.10% and 18.80% for hot water, ethanol and acetone respectively. Phytochemical screening of the extracts was also determined. Qualitative phytochemical screening showed that the plant extracts contained steroids, tannins, flavonoids and cardiac glycosides, while alkaloids, phlobatannin, terpenoids and anthraquinones were absent. Only ethanolic extract did not possess saponins. Aqueous extracts of J. curcas compared most favourably with the standard antibiotics (gentamycin) on all the coliform bacteria except on K. pneumoniae and E. coli likely due to a measurably higher antibacterial activity compared to the organic extracts. The minimum inhibitory concentration of the aqueous extract ranged from 3.00 to 7.00 mg/L while minimum bactericidal concentration ranged from 4.00 to 10.00 mg/L. Aqueous extract of J. curcas could be used as antibacterial agents against diseases caused by coliforms. PMID:24711746

  12. The presence of Enterococcus, coliforms and E. coli in a commercial yeast manufacturing process.

    PubMed

    O'Brien, S S; Lindsay, D; von Holy, A

    2004-07-01

    This study evaluated a typical commercial yeast manufacturing process for bacterial contamination. Product line samples of a commercial yeast manufacturing process and the corresponding seed yeast manufacturing process were obtained upstream from the final compressed and dry yeast products. All samples were analysed before (non-PI) and after preliminary incubation (PI) at 37 degrees C for 24 h. The PI procedure was incorporated for amplification of bacterial counts below the lower detection limit. Enterococcus, coliform and Escherichia coli counts were quantified by standard pour-plate techniques using selective media. Presence at all stages and progressive increases in counts of Enterococcus, coliforms and E. coli during processing in the commercial manufacturing operation suggested that the primary source of contamination of both compressed and dry yeast with these bacteria was the seed yeast manufacturing process and that contamination was amplified throughout the commercial yeast manufacturing process. This was confirmed by surveys of the seed yeast manufacturing process which indicated that contamination of the seed yeast with Enterococcus, coliforms and E. coli occurred during scale up of seed yeast biomass destined as inoculum for the commercial fermentation.

  13. Electrochemical disinfection of coliform and Escherichia coli for drinking water treatment by electrolysis method using carbon as an electrode

    NASA Astrophysics Data System (ADS)

    Riyanto; Agustiningsih, W. A.

    2018-04-01

    Disinfection of coliform and E. Coli in water has been performed by electrolysis using carbon electrodes. Carbon electrodes were used as an anode and cathode with a purity of 98.31% based on SEM-EDS analysis. This study was conducted using electrolysis powered by electric field using carbon electrode as the anode and cathode. Electrolysis method was carried out using variations of time (30, 60, 90, 120 minutes at a voltage of 5 V) and voltage (5, 10, 15, 20 V for 30 minutes) to determine the effect of the disinfection of the bacteria. The results showed the number of coliform and E. coli in water before and after electrolysis was 190 and 22 MPN/100 mL, respectively. The standards quality of drinking water No. 492/Menkes/Per/IV/2010 requires the zero content of coliform and E. Coli. Electrolysis with the variation of time and potential can reduce the number of coliforms and E. Coli but was not in accordance with the standards. The effect of hydrogen peroxide (H2O2) to the electrochemical disinfection was determined using UV-Vis spectrophotometer. The levels of H2O2 formed increased as soon after the duration of electrolysis voltage but was not a significant influence to the mortality of coliform and E.coli.

  14. Associations between fecal indicator bacteria prevalence and demographic data in private water supplies in Virginia.

    PubMed

    Smith, Tamara; Krometis, Leigh-Anne H; Hagedorn, Charles; Lawrence, Annie H; Benham, Brian; Ling, Erin; Ziegler, Peter; Marmagas, Susan West

    2014-12-01

    Over 1.7 million Virginians rely on private water sources to provide household water. The heaviest reliance on these systems occurs in rural areas, which are often underserved with respect to available financial resources and access to environmental health education. This study aimed to identify potential associations between concentrations of fecal indicator bacteria (FIB) (coliforms, Escherichia coli) in over 800 samples collected at the point-of-use from homes with private water supply systems and homeowner-provided demographic data (household income and education). Of the 828 samples tested, 349 (42%) of samples tested positive for total coliform and 55 (6.6%) tested positive for E. coli. Source tracking efforts targeting optical brightener concentrations via fluorometry and the presence of a human-specific Bacteroides marker via quantitative real-time polymerase chain reaction (qPCR) suggest possible contamination from human septage in over 20 samples. Statistical methods implied that household income has an association with the proportion of samples positive for total coliform, though the relationship between education level and FIB is less clear. Further exploration of links between demographic data and private water quality will be helpful in building effective strategies to improve rural drinking water quality.

  15. Inactivation, reactivation and regrowth of indigenous bacteria in reclaimed water after chlorine disinfection of a municipal wastewater treatment plant.

    PubMed

    Li, Dan; Zeng, Siyu; Gu, April Z; He, Miao; Shi, Hanchang

    2013-07-01

    Disinfection of reclaimed water prior to reuse is important to prevent the transmission of pathogens. Chlorine is a widely utilized disinfectant and as such is a leading contender for disinfection of reclaimed water. To understand the risks of chlorination resulting from the potential selection of pathogenic bacteria, the inactivation, reactivation and regrowth rates of indigenous bacteria were investigated in reclaimed water after chlorine disinfection. Inactivation of total coliforms, Enterococcus and Salmonella showed linear correlations, with constants of 0.1384, 0.1624 and 0.057 L/(mg.min) and R2 of 0.7617, 0.8316 and 0.845, respectively. However, inactivation of total viable cells by measurement of metabolic activity typically showed a linear correlation at lower chlorine dose (0-22 (mg-min)/L), and a trailing region with chlorine dose increasing from 22 to 69 (mg.min)/L. Reactivation and regrowth of bacteria were most likely to occur after exposure to lower chlorine doses, and extents of reactivation decreased gradually with increasing chlorine dose. In contrast to total coliforms and Enterococcus, Salmonella had a high level of regrowth and reactivation, and still had 2% regrowth even after chlorination of 69 (mg.min)/L and 24 hr storage. The bacterial compositions were also significantly altered by chlorination and storage of reclaimed water, and the ratio of Salmonella was significantly increased from 0.001% to 0.045% after chlorination of 69 (mg.min)/L and 24 hr storage. These trends indicated that chlorination contributes to the selection of chlorine-resistant pathogenic bacteria, and regrowth of pathogenic bacteria after chlorination in reclaimed water with a long retention time could threaten public health security during wastewater reuse.

  16. 40 CFR 141.803 - Coliform sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Coliform sampling. 141.803 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.803 Coliform sampling. (a) Analytical methodology. Air carriers must follow the sampling and analysis requirements under this section...

  17. 40 CFR 141.803 - Coliform sampling.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling. 141.803 Section 141...) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.803 Coliform sampling. (a) Analytical methodology. Air carriers must follow the sampling and analysis requirements under this section...

  18. Microbiological diversity and prevalence of spoilage and pathogenic bacteria in commercial fermented alcoholic beverages (beer, fruit wine, refined rice wine, and yakju).

    PubMed

    Jeon, Se Hui; Kim, Nam Hee; Shim, Moon Bo; Jeon, Young Wook; Ahn, Ji Hye; Lee, Soon Ho; Hwang, In Gyun; Rhee, Min Suk

    2015-04-01

    The present study examined 469 commercially available fermented alcoholic beverages (FABs), including beer (draft, microbrewed, and pasteurized), fruit wine (grape and others), refined rice wine, and yakju (raw and pasteurized). Samples were screened for Escherichia coli and eight foodborne pathogens (Bacillus cereus, Campylobacter jejuni, Clostridium perfringens, Escherichia coli O157:H7, Listeria monocytogenes, Salmonella spp., Staphylococcus aureus, and Yersinia enterocolitica), and the aerobic plate count, lactic acid bacteria, acetic acid bacteria, fungi, and total coliforms were also enumerated. Microbrewed beer contained the highest number of microorganisms (average aerobic plate count, 3.5; lactic acid bacteria, 2.1; acetic acid bacteria, 2.0; and fungi, 3.6 log CFU/ml), followed by draft beer and yakju (P < 0.05), whereas the other FABs contained , 25 CFU/25 ml microorganisms. Unexpectedly, neither microbial diversity nor microbial count correlated with the alcohol content (4.7 to 14.1%) or pH (3.4 to 4.2) of the product. Despite the harsh conditions, coliforms (detected in 23.8% of microbrewed beer samples) and B. cereus (detected in all FABs) were present in some products. B. cereus was detected most frequently in microbrewed beer (54.8% of samples) and nonpasteurized yakju (50.0%), followed by pasteurized yakju (28.8%), refined rice wine (25.0%), other fruit wines (12.3%), grape wine (8.6%), draft beer (5.6%), and pasteurized beer (2.2%) (P < 0.05). The finding that spore-forming B. cereus and coliform bacteria can survive the harsh conditions present in alcoholic beverages should be taken into account (alongside traditional quality indicators such as the presence of lactic acid-producing bacteria, acetic acid-producing bacteria, or both) when developing manufacturing systems and methods to prolong the shelf life of high-quality FAB products. New strategic quality management plans for various FABs are needed.

  19. [Evaluation of hydrocarbon-oxidizing bacteria in port water and of health risks related to harbour activities: port of Otranto (Italy)].

    PubMed

    De Donno, Antonella; Bagordo, Francesco; Rollo, Maria Concetta; Quattrocchi, Manuela; Campa, Annamaria; Guido, Marcello

    2006-01-01

    The aim of this study was to evaluate the water quality of the port of Otranto (Italy), through a combined approach which integrates monitoring of traditional microbiological parameters and studying the dynamics of some autochthonous bacterial communities. The fecal contamination indicators, total coliforms, fecal coliforms, and fecal streptococci were measured to evaluate the sanitary aspects, while the presence of organic matter was considered as a parameter strictly related to dumping. In addition, being the port of Otranto especially exposed to hydrocarbon pollution, hydrocarbon-oxidizing bacteria were evaluated. Fecal contamination indicators were consistently found to be below the threshold values set by the Italian legislative decree N. 470/82 for bathing waters, indicating a good microbiological quality of these waters. A higher density of hydrocarbon-oxidizing bacteria was found at mooring and craft transit areas. This parameter was therefore found to be useful for evaluating port water hydrocarbon pollution.

  20. Comparison of the New Millipore HC with Conventional Membrane Filters for the Enumeration of Fecal Coliform Bacteria

    PubMed Central

    Green, Barbara L.; Clausen, Elizabeth; Litsky, Warren

    1975-01-01

    Fecal coliform recoveries were determined for six types of membrane filters using 65 nonchlorinated water samples. Results showed that the membranes could be ranked in order of decreasing recovery as follows: Millipore HC > Gelman > Johns-Manville ∼ Sartorius > Millipore HA > Schleicher & Schuell. PMID:1103735

  1. Matrix Extension Study: Validation of the Compact Dry EC Method for Enumeration of Escherichia coli and non-E. coli Coliform Bacteria in Selected Foods.

    PubMed

    Mizuochi, Shingo; Nelson, Maria; Baylis, Chris; Green, Becky; Jewell, Keith; Monadjemi, Farinaz; Chen, Yi; Salfinger, Yvonne; Fernandez, Maria Cristina

    2016-01-01

    The Compact Dry "Nissui" EC method, originally certified by the AOAC Research Institute Performance Test Method(SM) program for enumeration of Escherichia coli and non-E. coli coliforms in raw meat products (Performance Tested Method(SM) 110402), has undergone an evaluation to extend the method's claim to cooked chicken, prewashed bagged shredded iceberg lettuce, frozen cod filets, instant nonfat dry milk powder, and pasteurized milk (2% fat). Compact Dry EC is a ready-to-use dry media sheet containing a cold-soluble gelling agent, selective agents, and a chromogenic medium, which are rehydrated by adding 1 mL diluted sample. E. coli form blue/blue-purple colonies, whereas other coliform bacteria form red/pink colonies. Users can obtain an E. coli count (blue/blue-purple colonies only) and a total coliform count (red/pink plus blue/blue-purple colonies) after 24 ± 2 h of incubation at 37 ± 1°C. The matrix extension study was organized by Campden BRI (formerly Campden and Chorleywood Food Research Association Technology, Ltd), Chipping Campden, United Kingdom. Method comparison data for cooked chicken, prewashed bagged shredded iceberg lettuce, frozen cod filets, and instant nonfat dry milk powder were collected in a single-laboratory evaluation by Campden BRI. A multilaboratory study was conducted on pasteurized milk (2% fat), with 13 laboratories participating. The Compact Dry EC method was compared to ISO 16649-2:2001 "Microbiology of food and animal feeding stuffs-Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli-Part 2: Colony-count technique at 44 degrees C using 5-bromo-4-chloro-3-indolyl beta-D-glucuronide" and to ISO 4832:2006 "Microbiology of food and animal feeding stuffs-Horizontal method for the enumeration of coliforms-Colony-count technique," the current standards at the time of this study. Each matrix was evaluated separately for E. coli and non-E. coli coliforms at each contamination level (including an

  2. 75 FR 71444 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-23

    ... laboratory analysis as required by the EC of the finished product including: Total aerobic bacteria, coliforms (30 [deg]C), coliforms (44.5 [deg]C), anaerobic sulphite-reducing bacteria (no gas production...

  3. Antagonistic effect of Lactobacillus strains against gas-producing coliforms isolated from colicky infants

    PubMed Central

    2011-01-01

    Background Infantile colic is a common disturb within the first 3 months of life, nevertheless the pathogenesis is incompletely understood and treatment remains an open issue. Intestinal gas production is thought to be one of the causes of abdominal discomfort in infants suffering from colic. However, data about the role of the amount of gas produced by infants' colonic microbiota and the correlation with the onset of colic symptoms are scanty. The benefit of supplementation with lactobacilli been recently reported but the mechanisms by which they exert their effects have not yet been fully defined. This study was performed to evaluate the interaction between Lactobacillus spp. strains and gas-forming coliforms isolated from stools of colicky infants. Results Strains of coliforms were isolated from stools of 45 colicky and 42 control breastfed infants in McConkey Agar and identified using PCR with species-specific primers, and the BBL™ Enterotube™ II system for Enterobacteriaceae. Gas-forming capability of coliforms was assessed in liquid cultures containing lactose as sole carbon source. The average count of total coliforms in colicky infants was significantly higher than controls: 5.98 (2.00-8.76) log10 vs 3.90 (2.50-7.10) CFU/g of faeces (p = 0.015). The following strains were identified: Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter aerogenes, Enterobacter cloacae and Enterococcus faecalis. Then, 27 Lactobacillus strains were tested for their antagonistic effect against coliforms both by halo-forming method and in liquid co-cultures. Lactobacillus delbrueckii subsp.delbrueckii DSM 20074 and L. plantarum MB 456 were able to inhibit all coliforms strains (halo-forming method), also in liquid co-cultures, thus demonstrating an antagonistic activity. Conclusions This study shows that two out of 27 strains of Lactobacillus examined possess an antimicrobial effect against six species of gas-forming coliforms isolated from colicky

  4. Antagonistic effect of Lactobacillus strains against gas-producing coliforms isolated from colicky infants.

    PubMed

    Savino, Francesco; Cordisco, Lisa; Tarasco, Valentina; Locatelli, Emanuela; Di Gioia, Diana; Oggero, Roberto; Matteuzzi, Diego

    2011-06-30

    Infantile colic is a common disturb within the first 3 months of life, nevertheless the pathogenesis is incompletely understood and treatment remains an open issue. Intestinal gas production is thought to be one of the causes of abdominal discomfort in infants suffering from colic. However, data about the role of the amount of gas produced by infants' colonic microbiota and the correlation with the onset of colic symptoms are scanty. The benefit of supplementation with lactobacilli been recently reported but the mechanisms by which they exert their effects have not yet been fully defined. This study was performed to evaluate the interaction between Lactobacillus spp. strains and gas-forming coliforms isolated from stools of colicky infants. Strains of coliforms were isolated from stools of 45 colicky and 42 control breastfed infants in McConkey Agar and identified using PCR with species-specific primers, and the BBL™ Enterotube™ II system for Enterobacteriaceae. Gas-forming capability of coliforms was assessed in liquid cultures containing lactose as sole carbon source. The average count of total coliforms in colicky infants was significantly higher than controls: 5.98 (2.00-8.76) log10 vs 3.90 (2.50-7.10) CFU/g of faeces (p = 0.015). The following strains were identified: Escherichia coli, Klebsiella pneumoniae, Klebsiella oxytoca, Enterobacter aerogenes, Enterobacter cloacae and Enterococcus faecalis. Then, 27 Lactobacillus strains were tested for their antagonistic effect against coliforms both by halo-forming method and in liquid co-cultures. Lactobacillus delbrueckii subsp. delbrueckii DSM 20074 and L. plantarum MB 456 were able to inhibit all coliforms strains (halo-forming method), also in liquid co-cultures, thus demonstrating an antagonistic activity. This study shows that two out of 27 strains of Lactobacillus examined possess an antimicrobial effect against six species of gas-forming coliforms isolated from colicky infants. Our findings may stimulate

  5. A high-performance doped photocatalysts for inactivation of total coliforms in superficial waters using different sources of radiation.

    PubMed

    Claro, Elis Marina Turini; Bidoia, Ederio Dino; de Moraes, Peterson Bueno

    2016-07-15

    Photocatalytic water treatment has a currently elevated electricity demand and maintenance costs, but the photocatalytic water treatment may also assist in overcoming the limitations and drawbacks of conventional water treatment processes. Among the Advanced Oxidation Processes, heterogeneous photocatalysis is one of the most widely and efficiently used processes to degrade and/or remove a wide range of polluting compounds. The goal of this work was to find out a highly efficient photocatalytic disinfection process in superficial water with different doped photocatalysts and using three sources of radiation: mercury vapor lamp, solar simulator and UV-A LED. Three doped photocatalysts were prepared, SiZnO, NSiZnO and FNSiZnO. The inactivation efficiency of each synthesized photocatalysts was compared to a TiO2 P25 (Degussa(®)) 0.5 g L(-1) control. Photolysis inactivation efficiency was 85% with UV-A LED, which is considered very high, demanding low electricity consumption in the process, whereas mercury vapor lamp and solar simulator yielded 19% and 13% inactivation efficiency, respectively. The best conditions were found with photocatalysts SiZnO, FNSiZnO and NSiZnO irradiated with UV-A LED, where efficiency exceeded 95% that matched inactivation of coliforms using the same irradiation and photocatalyst TiO2. All photocatalysts showed photocatalytic activity with all three radiation sources able to inactivate total coliforms from river water. The use of UV-A LED as the light source without photocatalyst is very promising, allowing the creation of cost-effective and highly efficient water treatment plants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. 40 CFR 141.802 - Coliform sampling plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...

  7. 40 CFR 141.802 - Coliform sampling plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...

  8. 40 CFR 141.802 - Coliform sampling plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...

  9. Spatial and Temporal Dynamics of Fecal Coliform and Associated with Suspended Solids and Water within Five Northern California Estuaries.

    PubMed

    Lewis, David J; Atwill, Edward R; Pereira, Maria das Graças C; Bond, Ronald

    2013-01-01

    Fecal coliform and associated with suspended solids (SS) and water in five northern California estuaries were studied to document process influences and water quality monitoring biases affecting indicator bacteria concentrations. We collected and analyzed 2371 samples during 10 sampling events for the five studied estuaries. Concentrations during wet-season stormflow conditions were greater than during wet-season base flow and dry-season base flow conditions. Results also document concentration gradients across the length of the studied estuaries and with depth of sample collection. Highest concentrations were associated with shallow samples collected furthest inland. Corresponding decreases occurred the deeper and closer to the estuary mouth a sample was collected. Results also identify direct relationships of wind speed and discharge velocity and indirect relationship of tide stage to indicator bacteria concentrations. Bacteria associated with suspended solids (SS), after conversion to the same units of measurement (mass), were three orders of magnitude greater than in the water fraction. However, the mean proportion contributed by SS to composite water sample concentrations was 8% (SE 0.3) for fecal coliform and 7% (SE 0.3) for . Bacteria from the SS proportion is related to seasonality, tide stage, and discharge velocity that are consistent with mechanisms for entrainment, transport of SS, and reduced particle settling. These results are important for both managing and monitoring these systems by improving sample spatial and temporal context and corresponding bacteria concentration values across the freshwater-saltwater interface. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  10. Swirl Flow Bioreactor coupled with Cu-alginate beads: A system for the eradication of Coliform and Escherichia coli from biological effluents.

    PubMed

    Atkinson, Sov; Thomas, Simon F; Goddard, Paul; Bransgrove, Rachel M; Mason, Paul T; Oak, Ajeet; Bansode, Anand; Patankar, Rohit; Gleason, Zachary D; Sim, Marissa K; Whitesell, Andrew; Allen, Michael J

    2015-05-21

    It is estimated that approximately 1.1 billion people globally drink unsafe water. We previously reported both a novel copper-alginate bead, which quickly reduces pathogen loading in waste streams and the incorporation of these beads into a novel swirl flow bioreactor (SFB), of low capital and running costs and of simple construction from commercially available plumbing pipes and fittings. The purpose of the present study was to trial this system for pathogen reduction in waste streams from an operating Dewats system in Hinjewadi, Pune, India and in both simulated and real waste streams in Seattle, Washington, USA. The trials in India, showed a complete inactivation of coliforms in the discharged effluent (Mean Log removal Value (MLRV) = 3.51), accompanied by a total inactivation of E. coli with a MLRV of 1.95. The secondary clarifier effluent also showed a 4.38 MLRV in viable coliforms during treatment. However, the system was slightly less effective in reducing E. coli viability, with a MLRV of 1.80. The trials in Seattle also demonstrated the efficacy of the system in the reduction of viable bacteria, with a LRV of 5.67 observed of viable Raoultella terrigena cells (100%).

  11. Factors Associated with the Presence of Coliforms in the Feed and Water of Feedlot Cattle

    PubMed Central

    Sanderson, Michael W.; Sargeant, Jan M.; Renter, David G.; Griffin, D. Dee; Smith, Robert A.

    2005-01-01

    The objective of this study was to investigate coliform counts in feedlot cattle water and feed rations and their associations with management, climate, fecal material, and water Escherichia coli O157 using a cross-sectional study design. Coliform counts were performed on feed samples from 671 pens on 70 feedlots and on water samples from 702 pens on 72 feedlots in four U.S. states collected between May and August 2001. Management and climate factors were obtained by survey and observation. Month of sampling (higher in May and June), presence of corn silage in the ration (negative association), temperature of the feed 1 in. (ca. 2.5 cm) below the surface at the time of sampling (negative association), and wind velocity at the time of sampling (positive association) were significantly associated with log10 coliform levels in feed. Month of sampling (lower in May versus June July and August), water pH (negative association), and water total solids (positive association) were significantly associated with log10 water coliform levels. Coliform counts in feed and water were not associated with prevalence of E. coli O157 in cattle feces or water. Management risk factors must be interpreted with caution but the results reported here do not support the use of coliform counts as a marker for E. coli O157 contamination of feed or water. PMID:16204517

  12. 40 CFR 141.802 - Coliform sampling plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Coliform sampling plan. 141.802... sampling plan. (a) Each air carrier under this subpart must develop a coliform sampling plan covering each... required actions, including repeat and follow-up sampling, corrective action, and notification of...

  13. 40 CFR 141.802 - Coliform sampling plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling plan. 141.802... sampling plan. (a) Each air carrier under this subpart must develop a coliform sampling plan covering each... required actions, including repeat and follow-up sampling, corrective action, and notification of...

  14. Efficacy of on-farm use of ultraviolet light for inactivation of bacteria in milk for calves.

    PubMed

    Gelsinger, S L; Heinrichs, A J; Jones, C M; Van Saun, R J; Wolfgang, D R; Burns, C M; Lysczek, H R

    2014-05-01

    Ultraviolet light is being employed for bacterial inactivation in milk for calves; however, limited evidence is available to support the claim that UV light effectively inactivates bacteria found in milk. Thus, the objective of this observational study was to investigate the efficacy of on-farm UV light treatment in reducing bacteria populations in waste milk used for feeding calves. Samples of nonsaleable milk were collected from 9 Pennsylvania herds, twice daily for 15 d, both before and after UV light treatment (n=60 samples per farm), and analyzed for standard plate count, coliforms, noncoliform, gram-negative bacteria, environmental and contagious streptococci, coagulase-negative staphylococci, Streptococcus agalactiae, Staphylococcus aureus count, and total solids percentage, and log reduction and percentage log reduction were calculated. Data were analyzed using the mixed procedure in SAS. In all bacteria types, samples collected after UV treatment contained significantly fewer bacteria compared with samples collected before UV treatment. Weighted least squares means for log reduction (percentage log reduction) were 1.34 (29%), 1.27 (58%), 1.48 (53%), 1.85 (55%), 1.37 (72%), 1.92 (63%), 1.07 (33%), and 1.67 (82%) for standard plate count, coliforms, noncoliform, gram-negative bacteria, environmental and contagious streptococci, Strep. agalactiae, coagulase-negative staphylococci, and Staph. aureus, respectively. A percentage log reduction greater than 50% was achieved in 6 of 8 bacteria types, and 43 and 94% of samples collected after UV treatment met recommended bacterial standards for milk for feeding calves. Based on these results, UV light treatment may be effective for some, but not all bacteria types found in nonsaleable waste milk. Thus, farmers should take into account the bacteria types that may need to be reduced when considering the purchase of a UV-treatment system. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc

  15. Estimation of total bacteria by real-time PCR in patients with periodontal disease.

    PubMed

    Brajović, Gavrilo; Popović, Branka; Puletić, Miljan; Kostić, Marija; Milasin, Jelena

    2016-01-01

    Periodontal diseases are associated with the presence of elevated levels of bacteria within the gingival crevice. The aim of this study was to evaluate a total amount of bacteria in subgingival plaque samples in patients with a periodontal disease. A quantitative evaluation of total bacteria amount using quantitative real-time polymerase chain reaction (qRT-PCR) was performed on 20 samples of patients with ulceronecrotic periodontitis and on 10 samples of healthy subjects. The estimation of total bacterial amount was based on gene copy number for 16S rRNA that was determined by comparing to Ct values/gene copy number of the standard curve. A statistically significant difference between average gene copy number of total bacteria in periodontal patients (2.55 x 10⁷) and healthy control (2.37 x 10⁶) was found (p = 0.01). Also, a trend of higher numbers of the gene copy in deeper periodontal lesions (> 7 mm) was confirmed by a positive value of coefficient of correlation (r = 0.073). The quantitative estimation of total bacteria based on gene copy number could be an important additional tool in diagnosing periodontitis.

  16. Comparative impacts of stormwater runoff on water quality of an urban, a suburban, and a rural stream.

    PubMed

    Mallin, Michael A; Johnson, Virginia L; Ensign, Scott H

    2009-12-01

    Water quality data at 12 sites within an urban, a suburban, and a rural stream were collected contemporaneously during four wet and eight dry periods. The urban stream yielded the highest biochemical oxygen demand (BOD), orthophosphate, total suspended sediment (TSS), and surfactant concentrations, while the most rural stream yielded the highest total organic carbon concentrations. Percent watershed development and percent impervious surface coverage were strongly correlated with BOD (biochemical oxygen demand), orthophosphate, and surfactant concentrations but negatively with total organic carbon. Excessive fecal coliform abundance most frequently occurred in the most urbanized catchments. Fecal coliform bacteria, TSS, turbidity, orthophosphate, total phosphorus, and BOD were significantly higher during rain events compared to nonrain periods. Total rainfall preceding sampling was positively correlated with turbidity, TSS, BOD, total phosphorus, and fecal coliform bacteria concentrations. Turbidity and TSS were positively correlated with phosphorus, fecal coliform bacteria, BOD, and chlorophyll a, which argues for better sedimentation controls under all landscape types.

  17. Fecal-indicator bacteria in the Newfound Creek watershed, western North Carolina, during a high and low streamflow condition, 2003

    USGS Publications Warehouse

    Giddings, Elise M.; Oblinger, Carolyn J.

    2004-01-01

    Water quality in the Newfound Creek watershed has been shown to be affected by bacteria, sediment, and nutrients. In this study, Escherichia coli (E. coli) bacteria were sampled at five sites in Newfound Creek and five tributary sites during low flow on May 28, 2003, and high flow on November 19, 2003. In addition, a subset of five sites was sampled for fecal coliform bacteria, E. coli bacteria in streambed sediments (low flow only), and coliphage virus for serotyping. Coliphage virus serotyping has been used to identify human and animal sources of bacterial contamination. A streamflow gage was installed and operated to support ongoing water-quality studies in the watershed. Fecal coliform densities ranged from 92 to 27,000 colony-forming units per 100 milliliters of water for E. coli and 140 to an estimated 29,000 colony-forming units per 100 milliliters of water for fecal coliform during the two sampling visits. Ninety percent of the E. coli and fecal coliform samples exceeded corresponding U.S. Environmental Protection Agency or North Carolina water-quality criteria for recreational and ambient waters. During low flow, the middle part of the Newfound Creek watershed and the Dix Creek tributary had the highest densities of E. coli bacteria. During the high-flow sampling, all tributaries contained high densities of E. coli bacteria, although Dix Creek and Round Hill Branch were the largest contributors of these bacteria to Newfound Creek. Coliphage virus serotyping results were inconclusive because most samples did not contain the male-specific RNA coliphage needed for serotyping. Positive results indicated, however, that during low flow, non-human sources of bacteria were present in Sluder Branch, and during high flow, human sources of bacteria were present in Round Hill Branch. Sampling of bacteria in streambed sediments during low flow indicated that sediments do not appear to be a substantial source of bacteria relative to the water column, with the exception

  18. Fresh steam-flaked corn in cattle feedlots is an important site for fecal coliform contamination by house flies.

    PubMed

    Ghosh, Anuradha; Zurek, Ludek

    2015-03-01

    House flies are a common pest at food animal facilities, including cattle feedlots. Previously, house flies were shown to play an important role in the ecology of Escherichia coli O157:H7; house flies in cattle feedlots carried this zoonotic pathogen and were able to contaminate cattle through direct contact and/or by contamination of drinking water and feed. Because house flies aggregate in large numbers on fresh ( # 6 h) steam-flaked corn (FSFC) used in cattle feed, the aim of this study was to assess FSFC in a cattle feedlot as a potentially important site of fecal coliform contamination by house flies. House flies and FSFC samples were collected, homogenized, and processed for culturing of fecal coliforms on membrane fecal coliform agar. Selected isolates were identified by 16S rRNA gene sequencing, and representative isolates from each phylogenetic group were genotyped by pulsed-field gel electrophoresis. Fecal coliforms were undetectable in FSFC shortly (0 h) after flaking; however, in summer, after 4 to 6 h, the concentrations of fecal coliforms ranged from 1.9 × 10(3) to 3.7 × 10(4) CFU/g FSFC (mean, 1.1 ± 3.0 × 10(4) CFU/g). House flies from FSFC carried between 7.6 × 10(2) and 4.1 × 10(6) CFU of fecal coliforms per fly (mean, 6.0 ± 2.3 × 10(5) CFU per fly). Fecal coliforms were represented by E. coli (85.1%), Klebsiella spp. (10.6%), and Citrobacter spp. (4.3%). Pulsed-field gel electrophoresis demonstrated clonal matches of E. coli and Klebsiella spp. between house flies and FSFC. In contrast, in winter and in the absence of house flies, the contamination of corn by fecal coliforms was significantly (∼10-fold) lower. These results indicate that FSFC is an important site for bacterial contamination by flies and possible exchange of E. coli and other bacteria among house flies. Further research is needed to evaluate the potential use of screens or blowers to limit the access of house flies to FSFC and therefore their effectiveness in preventing

  19. Viruses and bacteria in karst and fractured rock aquifers in east Tennessee, USA

    USGS Publications Warehouse

    Johnson, T.B.; McKay, L.D.; Layton, A.C.; Jones, S.W.; Johnson, G.C.; Cashdollar, J.L.; Dahling, D.R.; Villegas, L.F.; Fout, G.S.; Williams, D.E.; Sayler, G.

    2011-01-01

    A survey of enteric viruses and indicator bacteria was carried out in eight community water supply sources (four wells and four springs) in East Tennessee. Seven sites derived their water from carbonate aquifers and one from fractured sandstone. Four of the sites were deemed "low-risk" based on prior monitoring of fecal indicators and factors such as presence of thick layers of overlying sediments. The remaining sites were deemed "high-risk." Enteric viruses (enterovirus and reovirus) were detected by cell culture at least once in seven of the eight wells or springs including all but one of the four low-risk sites. Viral RNA, however, was not detected in any of the samples by reverse transcription-polymerase chain reaction. Conventional indicators of microbial contamination (Escherichia coli and total coliform bacteria) were detected together with culturable viruses in seven of nine virus positive samples. Bacteroides, an alternative fecal indicator which has not previously been used in groundwater investigations, was also detected in all but one of the samples containing E. coli or total coliform bacteria, as well as in one sample where viruses were present in the absence of other bacterial indicators. The study highlights some of the challenges involved in surveys of virus occurrence and indicates that culturable enteric viruses in East Tennessee karst aquifers may be more widespread than previously observed in studies of karst aquifers in Pennsylvania (8%), the Ozark region of Missouri (< 1%), or several other states covered in a national microbial water quality survey conducted by the U.S. Environmental Protection Agency (43%). Copyright ?? 2010 The Author(s). Journal compilation ?? 2010 National Ground Water Association.

  20. Seasonal variation of fecal indicator bacteria in storm events within the US stormwater database.

    PubMed

    Pan, Xubin; Jones, Kim D

    2012-01-01

    Bacteria are one of the major causes of surface water impairments in the USA. Over the past several years, best management practices, including detention basins, manufactured devices, grass swales, filters and bioretention cells have been used to remove bacteria and other pollutants from stormwater runoff. However, there are data gaps in the comprehensive studies of bacteria concentrations in stormwater runoff. In this paper, the event mean concentration (EMC) of fecal indicator bacteria (Enterococcus, Escherichia coli, fecal Streptococcus group bacteria, and fecal coliform) across the USA was retrieved from the international stormwater best management practices database to analyze the seasonal variations of inflow and outflow event mean concentrations and removal efficiencies. The Kruskal-Wallis test was employed to determine the seasonal variations of bacteria indicator concentrations and removals, and the two-sample Kolmogorov-Smirnov test was used for comparing different seasonal outcomes. The results indicate that all the inflow EMC of FIB in stormwater runoff is above the water quality criteria. The seasonal differences of fecal Streptococcus group bacteria and fecal coliform are significant. Summer has the potential to increase the bacteria EMC and illustrate the seasonal differences.

  1. Aquatic indicator bacteria in the high alpine zone.

    PubMed

    Stuart, S A; McFeters, G A; Schillinger, J E; Stuart, D G

    1976-02-01

    Selected waters from the high alpine zone within Grand Teton National Park, Wyoming, were analyzed for populations of indicator bacteria during the past three summers to determine the influence of various factors on the quality of these waters. In general the water quality was not significantly influenced by the presence or absence of human visitors but rather by the nature of the biological community through which the streams flowed. A minority of the coliforms that were recovered from all of the sites proved to be fecal coliforms. The fecal streptococci isolated were identified as the species that were found primarily in the fecal material of the native rodent and moose populations. It is concluded that management questions that relate to the carrying capacity of alpine areas should be approached with the aid of other biological parameters along with levels of indicator bacteria in the streams.

  2. Identification of coliform genera recovered from water using different technologies.

    PubMed

    Fricker, C R; Eldred, B J

    2009-12-01

    Methods for the detection of coliforms in water have changed significantly in recent years with procedures incorporating substrates for the detection of beta-d-galactosidase becoming more widely used. This study was undertaken to determine the range of coliform genera detected with methods that rely on lactose fermentation and compare them to those recovered using methods based upon beta-d-galactosidase. Coliform isolates were recovered from sewage-polluted water using m-endo, membrane lauryl sulfate broth, tergitol TTC agar, Colilert-18, ChromoCult and ColiScan for primary isolation. Organisms were grouped according to whether they had been isolated based upon lactose fermentation or beta-d-galactosidase production. A wide range of coliform genera were detected using both types of methods. There was considerable overlap between the two groups, and whilst differences were seen between the genera isolated with the two method types, no clear pattern emerged. Substantial numbers of 'new' coliforms (e.g. Raoutella spp.) were recovered using both types of methods. The results presented here confirm that both methods based on lactose fermentation or detection of beta-d-galactosidase activity recover a range of coliform organisms. Any suggestion that only methods which are based upon fermentation of lactose recover organisms of public health or regulatory significance cannot be substantiated. Furthermore, the higher recovery of coliform organisms from sewage-polluted water using methods utilizing beta-d-galactosidase-based methods does not appear to be because of the recovery of substantially more 'new' coliforms.

  3. Detection of multiple potentially pathogenic bacteria in Matang mangrove estuaries, Malaysia.

    PubMed

    Ghaderpour, Aziz; Mohd Nasori, Khairul Nazrin; Chew, Li Lee; Chong, Ving Ching; Thong, Kwai Lin; Chai, Lay Ching

    2014-06-15

    The deltaic estuarine system of the Matang Mangrove Forest Reserve of Malaysia is a site where several human settlements and brackish water aquaculture have been established. Here, we evaluated the level of fecal indicator bacteria (FIB) and the presence of potentially pathogenic bacteria in the surface water and sediments. Higher levels of FIB were detected at downstream sampling sites from the fishing village, indicating it as a possible source of anthropogenic pollution to the estuary. Enterococci levels in the estuarine sediments were higher than in the surface water, while total coliforms and E. coli in the estuarine sediments were not detected in all samples. Also, various types of potentially pathogenic bacteria, including Klebsiella pneumoniae, Serratia marcescens and Enterobacter cloacae were isolated. The results indicate that the Matang estuarine system is contaminated with various types of potential human bacterial pathogens which might pose a health risk to the public. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Water quality in the Withers Swash Basin, with emphasis on enteric bacteria, Myrtle Beach, South Carolina, 1991-93

    USGS Publications Warehouse

    Guimaraes, W.B.

    1995-01-01

    Water samples were collected in 1991-93 from Withers Swash and its two tributaries (the Mainstem and KOA Branches) in Myrtle Beach, S.C., and analyzed for physical properties, organic and inorganic constituents, and fecal coliform and streptococcus bacteria. Samples were collected during wet- and dry-weather conditions to assess the water quality of the streams before and after storm runoff. Water samples were analyzed for over 200 separate physical, chemical, and biological constituents. Concentrations of 11 constituents violated State criteria for shellfish harvesting waters, and State Human Health Criteria. The 11 constituents included concentrations of dissolved oxygen, arsenic, lead, cadmium, mercury, chlordane, dieldrin, 1,1,1-trichloroethane, 1,1-dichloroethylene, trichloroethylene, and fecal coliform bacteria. Water samples were examined for the presence of enteric bacteria (fecal coliform and fecal streptococcus) at 46 sites throughout the Withers Swash Basin and 5 sites on the beach and in the Atlantic Ocean. Water samples were collected just upstream from all confluences in order to determine sources of bacterial contamination. Temporally and spatially high concentrations of enteric bacteria were detected throughout the Withers Swash Basin; however, these sporadic bacteria concentrations made it difficult to determine a single source of the contamination. These enteric bacteria concentrations are probably derived from a number of sources in the basin including septic tanks, garbage containers, and the feces of waterfowl and domestic animals.

  5. A Synoptic Study of Fecal-Indicator Bacteria in the Wind River, Bighorn River, and Goose Creek Basins, Wyoming, June-July 2000

    USGS Publications Warehouse

    Clark, Melanie L.; Gamper, Merry E.

    2003-01-01

    A synoptic study of fecal-indicator bacteria was conducted during June and July 2000 in the Wind River, Bighorn River, and Goose Creek Basins in Wyoming as part of the U.S. Geological Survey's National Water-Quality Assessment Program for the Yellowstone River Basin. Fecal-coliform concentrations ranged from 2 to 3,000 col/100 mL (colonies per 100 milliliters) for 100 samples, and Escherichia coli concentrations ranged from 1 to 2,800 col/100 mL for 97 samples. Fecal-coliform concentrations exceeded the U.S. Environmental Protection Agency's recommended limit for a single sample for recreational contact with water in 37.0 percent of the samples. Escherichia coli concentrations exceeded the U.S. Environmental Protection Agency's recommended limit for a single sample for moderate use, full-body recreational contact with water in 38.1 percent of the samples and the recommended limit for infrequent use, full-body recreational contact with water in 24.7 percent of the samples. Fecal-indicator-bacteria concentrations varied by basin. Samples from the Bighorn River Basin had the highest median concentrations for fecal coliform of 340 col/100 mL and for Escherichia coli of 300 col/100 mL. Samples from the Wind River Basin had the lowest median concentrations for fecal coliform of 50 col/100 mL and for Escherichia coli of 62 col/100 mL. Fecal-indicator-bacteria concentrations varied by land cover. Samples from sites with an urban land cover had the highest median concentrations for fecal coliform of 540 col/100 mL and for Escherichia coli of 420 col/100 mL. Maximum concentrations for fecal coliform of 3,000 col/100 mL and for Escherichia coli of 2,800 col/100 mL were in samples from sites with an agricultural land cover. The lowest median concentrations for fecal coliform of 130 col/100 mL and for Escherichia coli of 67 col/100 mL were for samples from sites with a forested land cover. A strong and positive relation existed between fecal coliform and Escherichia coli

  6. Wastewater disinfection alternatives: chlorine, ozone, peracetic acid, and UV light.

    PubMed

    Mezzanotte, V; Antonelli, M; Citterio, S; Nurizzo, C

    2007-11-01

    Disinfection tests were carried out at pilot scale to compare the disinfection efficiency of ozone, sodium hypochlorite (NaOCl), peracetic acid (PAA), and UV irradiation. Total coliforms, fecal coliforms, and Escherichia coli were monitored as reference microorganisms. Total heterotrophic bacteria (THB) were also enumerated by cytometry. At similar doses, NaOCl was more effective than PAA, and its action was less affected by contact time. The results obtained by ozonation were comparable for total coliforms, fecal coliforms, and E. coli. On the contrary, some differences among the three indicators were observed for NaOCl, PAA, and UV. Differences increased with increasing values of the disinfectant concentration times contact time (C x t) and were probably the result of different initial counts, as total coliforms include fecal coliforms, which include E. coli. The UV irradiation lead to complete E. coli removals, even at low doses (10 to 20 mJ/cm2). Total heterotrophic bacteria appeared to be too wide a group to be a good disinfection indicator; no correlation was found among THB inactivation, dose, and contact time.

  7. Fecal-indicator bacteria and Escherichia coli pathogen data collected near a novel sub-irrigation water-treatment system in Lenawee County, Michigan, June-November 2007

    USGS Publications Warehouse

    Duris, Joseph W.; Beeler, Stephanie

    2008-01-01

    The U.S. Geological Survey, in cooperation with the Lenawee County Conservation District in Lenawee County, Mich., conducted a sampling effort over a single growing season (June to November 2007) to evaluate the microbiological water quality around a novel livestock reservoir wetland sub-irrigation system. Samples were collected and analyzed for fecal coliform bacteria, Escherichia coli (E. coli) bacteria, and six genes from pathogenic strains of E. coli.A total of 73 water-quality samples were collected on nine occasions from June to November 2007. These samples were collected within the surface water, shallow ground water, and the manure-treatment system near Bakerlads Farm near Clayton in Lenawee County, Mich. Fecal coliform bacteria concentrations ranged from 10 to 1.26 million colony forming units per 100 milliliters (CFU/100 mL). E. coli bacteria concentrations ranged from 8 to 540,000 CFU/100 mL. Data from the E. coli pathogen analysis showed that 73 percent of samples contained the eaeA gene, 1 percent of samples contained the stx2 gene, 37 percent of samples contained the stx1 gene, 21 percent of samples contained the rfbO157 gene, and 64 percent of samples contained the LTIIa gene.

  8. Enteric Viruses and Fecal Bacteria Indicators to Assess Groundwater Quality and Suitability for Irrigation

    PubMed Central

    De Giglio, Osvalda; Caggiano, Giuseppina; Bagordo, Francesco; Barbuti, Giovanna; Brigida, Silvia; Lugoli, Federica; Grassi, Tiziana; La Rosa, Giuseppina; Lucentini, Luca; Uricchio, Vito Felice; De Donno, Antonella; Montagna, Maria Teresa

    2017-01-01

    According to Italian Ministerial Decree No. 185 of 12 June 2003, water is considered suitable for irrigation if levels of fecal bacteria (i.e., Escherichia coli and Salmonella) are within certain parameters. The detection of other microorganisms is not required. The aim of this study is to determine the bacteriological quality of groundwater used for irrigation and the occurrence of enteric viruses (Norovirus, Enterovirus, Rotavirus, Hepatovirus A), and to compare the presence of viruses with the fecal bacteria indicators. A total of 182 wells was analyzed. Widespread fecal contamination of Apulian aquifers was detected (141 wells; 77.5%) by the presence of fecal bacteria (i.e., E. coli, Salmonella, total coliforms, and enterococci). Considering bacteria included in Ministerial Decree No. 185, the water from 35 (19.2%) wells was unsuitable for irrigation purposes. Among 147 wells with water considered suitable, Norovirus, Rotavirus, and Enterovirus were detected in 23 (15.6%) wells. No Hepatovirus A was isolated. Consequently, 58 wells (31.9%) posed a potential infectious risk for irrigation use. This study revealed the inadequacy of fecal bacteria indicators to predict the occurrence of viruses in groundwater and it is the first in Italy to describe the presence of human rotaviruses in well water used for irrigation. PMID:28538682

  9. Evaluation of the lactose Tergitol-7, m-Endo LES, Colilert 18, Readycult Coliforms 100, Water-Check-100, 3M Petrifilm EC and DryCult Coliform test methods for detection of total coliforms and Escherichia coli in water samples.

    PubMed

    Hörman, Ari; Hänninen, Marja-Liisa

    2006-10-01

    In this study we compared the reference membrane filtration (MF) lactose Tergitol-7 (LTTC) method ISO 9308-1:2000 with the MF m-Endo LES method SFS 3016:2001, the defined substrate chromogenic/fluorogenic Colilert 18, Readycult Coliforms and Water Check methods, and ready-made culture media, 3M Petrifilm EC and DryCult Coli methods for the detection of coliforms and Escherichia coli in various water samples. When the results of E. coli detection were compared between test methods, the highest agreement (both tests negative or positive) with the LTTC method was calculated for the m-Endo LES method (83.6%), followed by Colilert 18 (82.7%), Water-Check (81.8%) and Readycult (78.4%), whereas Petrifilm EC (70.6%) and DryCult Coli (68.9%) showed the weakest agreement. The m-Endo LES method was the only method showing no statistical difference in E. coli counts compared with the LTTC method, whereas the Colilert 18 and Readycult methods gave significantly higher counts for E. coli than the LTTC method. In general, those tests based on the analysis of a 1-ml sample (Petrifilm EC and DryCult Coli) showed weak sensitivity (39.5-52.5%) but high specificity (90.9-78.8%).

  10. Frequency of indicator bacteria, Salmonella and diarrhoeagenic Escherichia coli pathotypes on ready-to-eat cooked vegetable salads from Mexican restaurants.

    PubMed

    Bautista-De León, H; Gómez-Aldapa, C A; Rangel-Vargas, E; Vázquez-Barrios, E; Castro-Rosas, J

    2013-06-01

    The presence of coliform bacteria, faecal coliforms, Escherichia coli, diarrhoeagenic E. coli pathotypes (DEP) and Salmonella were determined in ready-to-eat cooked vegetable salads (RECS) from restaurants in Pachuca city, Mexico. The RECS were purchased from three types of restaurants: national chain restaurants (A), local restaurants (B) and small restaurants (C). Two restaurants for each A and B, and three for C, were included. Forty RECS samples were purchased at each A and B restaurant and 20 at each C restaurant. Of the overall total of 220 analysed samples, 100, 98·2, 72·3, 4·1 and 4·1% had coliform bacteria, faecal coliforms, E. coli, DEP and Salmonella, respectively. Identified DEP included enteropathogenic E. coli (EPEC), enterotoxigenic E. coli (ETEC) and Shiga toxin-producing E. coli (STEC). The EPEC, ETEC and STEC were isolated each from 1·4% of samples. No E. coli O157:H7 were detected in any STEC-positive samples. The analysis of Kruskal-Wallis anova and median test of microbiological data showed that the microbiological quality of RECS did not differ between the different restaurants (P > 0·05). This is the first report regarding microbiological quality and Salmonella, enteropathogenic E. coli (EPEC), enterotoxigenic E. coli (ETEC) and Shiga toxin-producing E. coli (STEC) isolation from ready-to-eat cooked vegetable salads from Mexican restaurants. Ready-to-eat cooked vegetable salads could be an important factor contributing to the endemicity of EPEC, ETEC and STEC, and Salmonella caused gastroenteritis in Mexico. © 2013 The Society for Applied Microbiology.

  11. Predicting Fecal Indicator Bacteria Fate and Removal in Urban Stormwater at the Watershed Scale

    NASA Astrophysics Data System (ADS)

    Wolfand, J.; Hogue, T. S.; Luthy, R. G.

    2016-12-01

    Urban stormwater is a major cause of water quality impairment, resulting in surface waters that fail to meet water quality standards and support their designated uses. Of the many stormwater pollutants, fecal indicator bacteria are particularly important to track because they are directly linked to pathogens which jeopardize public health; yet, their fate and transport in urban stormwater is poorly understood. Monitoring fecal bacteria in stormwater is possible, but due to the high variability of fecal indicators both spatially and temporally, single grab or composite samples do not fully capture fecal indicator loading. Models have been developed to predict fecal indicator bacteria at the watershed scale, but they are often limited to agricultural areas, or areas that receive frequent rainfall. Further, it is unclear whether best management practices (BMPs), such as bioretention or engineered wetlands, are able to reduce bacteria to meet water quality standards at watershed outlets. This research seeks to develop a model to predict fecal indicator bacteria in urban stormwater in a semi-arid climate at the watershed scale. Using the highly developed Ballona Creek watershed (89 mi2) located in Los Angeles County as a case study, several existing mechanistic models are coupled with a hydrologic model to predict fecal indicator concentrations (E. coli, enterococci, fecal coliform, and total coliform) at the outfall of Ballona Creek watershed, Santa Monica Bay. The hydrologic model was developed using InfoSWMM Sustain, calibrated for flow from WY 1998-2006 (NSE = 0.94; R2 = 0.95), and validated from WY 2007-2015 (NSE = 0.93; R2 = 0.95). The developed coupled model is being used to predict fecal indicator fate and transport and evaluate how BMPs can be optimized to reduce fecal indicator loading to surface waters and recreational beaches.

  12. Ranking of the Ecological Disaster Areas According to Coliform Contamination and the Incidence of Acute Enteric Infections of the Population in Kyzylorda Region

    ERIC Educational Resources Information Center

    Omarova, Mariya N.; Orakbay, Lyazzat Zh.; Shuratov, Idelbay H.; Kenjebayeva, Asiya T.; Zhumagalieva, Aizhan B.; Sarsenova, Ainur B.

    2016-01-01

    The paper is devoted to monitoring the environmental coliform bacteria (CB) contamination (soil and water) in the environmental disaster areas in the Kazakhstan part of the Aral Sea Region and ranking districts by their level of contamination and the rate of gastrointestinal infections (GI). The research was done in environmental disaster areas…

  13. Changes in Microbial Communities, Including both Uncultured and Culturable Bacteria, with Mid-Ocean Ballast-Water Exchange during a Voyage from Japan to Australia

    PubMed Central

    Tomaru, Akiko; Kawachi, Masanobu; Demura, Mikihide; Fukuyo, Yasuwo

    2014-01-01

    We assessed changes in the microbial communities in ballast water during a trans-Pacific voyage from Japan to Australia that included a mid-ocean ballast-water exchange. Uncultured (i.e., total) and culturable bacteria were counted and were characterized by using denaturing gradient gel electrophoresis (DGGE). There was a clear decrease over time in numbers of uncultured microorganisms, except for heterotrophic nanoflagellates, whereas the abundance of culturable bacteria initially decreased after the ballast-water exchange but then increased. The increase, however, was only up to 5.34% of the total number of uncultured bacteria. Cluster analysis showed that the DGGE profiles of uncultured bacteria clearly changed after the exchange. In contrast, there was no clear change in the DGGE profiles of culturable bacteria after the exchange. Multidimensional scaling analysis showed changes in microbial communities over the course of the voyage. Although indicator microbes as defined by the International Convention for the Control and Management of Ships' Ballast Water and Sediments were occasionally detected, no coliform bacteria were detected after the exchange. PMID:24817212

  14. Fate and Enumeration Problems of Fecal Coliform Bacteria in Runoff Waters from Terrestrial Ecosystems.

    DTIC Science & Technology

    1980-09-01

    bacteria and also for the development of a surface organic layer on the plots that aided in the removal of wastewater bacteria through filtration and...better conditions not only for protozoan predation of fecal bacteria but also for the development of a surface organic layer on the plots. This organic... layer acted to increase the detention of the wastewater bacteria through filtration and entrapment. The intermittently treated plots promoted the

  15. Microbiological quality of fresh produce obtained from retail stores on the Eastern Shore of Maryland, United States of America.

    PubMed

    Korir, Robert Cheruiyot; Parveen, Salina; Hashem, Fawzy; Bowers, John

    2016-06-01

    The aim of this study was to investigate the microbiological quality of six types of fresh produce obtained from three retail stores located on the Eastern Shore of Maryland, USA. A total of 414 samples representing basil, cilantro, lettuce, scallion, spinach, and parsley were analyzed for total aerobic bacteria (APC), total coliforms, Escherichia coli, and three pathogenic bacteria (E. coli O157:H7, Listeria monocytogenes, and Salmonella), using standard methods. Presumptive pathogenic isolates were confirmed using BAX Polymerase Chain Reaction. Total aerobic populations varied widely between samples, while 38.41% were positive for total coliforms and only 10.15% for E. coli. Median abundance (log CFU/g) of total coliforms and E. coli were less than the limit of detection and that of APC ranged from 5.78 to 6.61 over the six produce types. There was a statistically significant difference in prevalence of total coliforms among the retail stores, but not for abundance of APC or prevalence of E. coli. E. coli O157:H7 and L. monocytogenes were detected in one spinach sample each, while one parsley and one cilantro sample were positive for Salmonella. There were no statistically significant differences in microbiological quality among produce types. Although the results of this study provided some indices of sanitary and/or spoilage level, no relationship was observed among the total aerobic bacteria, total coliforms, E. coli, and the presence of pathogenic bacteria in the samples tested. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Occurrence of bacteria in Blue Marsh Lake and selected tributaries, Berks County, Pennsylvania; September-October 2001

    USGS Publications Warehouse

    Zimmerman, Michele L.

    2002-01-01

    The Commonwealth of Pennsylvania has water-quality standards that limit the number of specific bacteria in water that is considered safe for recreational use. Bacteria such as fecal streptococci, fecal coliforms, and Escherichia coli (E. coli) are used to assess recreational water quality because they usually live in the intestines of warm-blooded animals. Fecal indicator bacteria commonly are associated with waterborne disease-causing organisms (pathogens). These indicator bacteria are used routinely as a measure of the quality of water for recreational activities such as swimming, boating, and water skiing. If the indicator bacteria are present, effective measures could be taken to prevent the transmission or epidemic outbreak of waterborne diseases as a result of contamination of these waters from human or animal waste.Blue Marsh Lake is on Tulpehocken Creek in Berks County, Pa., and drains a largely agricultural basin. Land use in the basin is approximately 60 percent cropland, and 85 percent of the farms are livestock and poultry farms.The potential sources of fecal bacteria are:geese that inhabit the recreational areas of the lake,humans that visit the Dry Brooks Day Use Area (swimming area), andfarm animals, wastewater facilities, and household septic systems in the basin (bacteria from these sources could enter the lake through tributaries).To meet the recreational water-quality standard, lake water may not have more than 200 colony-forming units (CFU) of fecal coliforms per 100 milliliters (mL). During the week of July 23, 2001, data collected by the U.S. Army Corps of Engineers (USACE) at the swimming area at Blue Marsh Lake showed concentrations of fecal coliforms in the water exceeding the standard. To determine the extent of elevated concentrations of fecal indicator bacteria, further study of the lake and selected tributaries was needed.

  17. Impact of fertilizing with raw or anaerobically digested sewage sludge on the abundance of antibiotic-resistant coliforms, antibiotic resistance genes, and pathogenic bacteria in soil and on vegetables at harvest.

    PubMed

    Rahube, Teddie O; Marti, Romain; Scott, Andrew; Tien, Yuan-Ching; Murray, Roger; Sabourin, Lyne; Zhang, Yun; Duenk, Peter; Lapen, David R; Topp, Edward

    2014-11-01

    The consumption of crops fertilized with human waste represents a potential route of exposure to antibiotic-resistant fecal bacteria. The present study evaluated the abundance of bacteria and antibiotic resistance genes by using both culture-dependent and molecular methods. Various vegetables (lettuce, carrots, radish, and tomatoes) were sown into field plots fertilized inorganically or with class B biosolids or untreated municipal sewage sludge and harvested when of marketable quality. Analysis of viable pathogenic bacteria or antibiotic-resistant coliform bacteria by plate counts did not reveal significant treatment effects of fertilization with class B biosolids or untreated sewage sludge on the vegetables. Numerous targeted genes associated with antibiotic resistance and mobile genetic elements were detected by PCR in soil and on vegetables at harvest from plots that received no organic amendment. However, in the season of application, vegetables harvested from plots treated with either material carried gene targets not detected in the absence of amendment. Several gene targets evaluated by using quantitative PCR (qPCR) were considerably more abundant on vegetables harvested from sewage sludge-treated plots than on vegetables from control plots in the season of application, whereas vegetables harvested the following year revealed no treatment effect. Overall, the results of the present study suggest that producing vegetable crops in ground fertilized with human waste without appropriate delay or pretreatment will result in an additional burden of antibiotic resistance genes on harvested crops. Managing human exposure to antibiotic resistance genes carried in human waste must be undertaken through judicious agricultural practice. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  18. Impact of Fertilizing with Raw or Anaerobically Digested Sewage Sludge on the Abundance of Antibiotic-Resistant Coliforms, Antibiotic Resistance Genes, and Pathogenic Bacteria in Soil and on Vegetables at Harvest

    PubMed Central

    Rahube, Teddie O.; Marti, Romain; Scott, Andrew; Tien, Yuan-Ching; Murray, Roger; Sabourin, Lyne; Zhang, Yun; Duenk, Peter; Lapen, David R.

    2014-01-01

    The consumption of crops fertilized with human waste represents a potential route of exposure to antibiotic-resistant fecal bacteria. The present study evaluated the abundance of bacteria and antibiotic resistance genes by using both culture-dependent and molecular methods. Various vegetables (lettuce, carrots, radish, and tomatoes) were sown into field plots fertilized inorganically or with class B biosolids or untreated municipal sewage sludge and harvested when of marketable quality. Analysis of viable pathogenic bacteria or antibiotic-resistant coliform bacteria by plate counts did not reveal significant treatment effects of fertilization with class B biosolids or untreated sewage sludge on the vegetables. Numerous targeted genes associated with antibiotic resistance and mobile genetic elements were detected by PCR in soil and on vegetables at harvest from plots that received no organic amendment. However, in the season of application, vegetables harvested from plots treated with either material carried gene targets not detected in the absence of amendment. Several gene targets evaluated by using quantitative PCR (qPCR) were considerably more abundant on vegetables harvested from sewage sludge-treated plots than on vegetables from control plots in the season of application, whereas vegetables harvested the following year revealed no treatment effect. Overall, the results of the present study suggest that producing vegetable crops in ground fertilized with human waste without appropriate delay or pretreatment will result in an additional burden of antibiotic resistance genes on harvested crops. Managing human exposure to antibiotic resistance genes carried in human waste must be undertaken through judicious agricultural practice. PMID:25172864

  19. Occurrence of tetracycline-resistant fecal coliforms and their resistance genes in an urban river impacted by municipal wastewater treatment plant discharges.

    PubMed

    Zhang, Chong-Miao; Du, Cong; Xu, Huan; Miao, Yan-Hui; Cheng, Yan-Yan; Tang, Hao; Zhou, Jin-Hong; Wang, Xiao-Chang

    2015-01-01

    Antibiotic resistance of fecal coliforms in an urban river poses great threats to both human health and the environment. To investigate the occurrence and distribution of antibiotic resistant bacteria in an urban river, water samples were collected from the Chanhe River in Xi'an, China. After membrane filtration of water samples, the tetracycline resistance rate of fecal coliforms and their resistance genes were detected by plating and polymerase chain reaction (PCR), respectively. We found that fecal coliforms were generally resistant to tetracycline and saw average resistance rates of 44.7%. The genes tetA and tetB were widely detected, and their positive rate was 60%-100% and 40%-90%, respectively. We found few strains containing tetC, tetK, tetQ and tetX, and we did not identify any strains containing tetG, tetM or tetO. The prevalence of tetA and tetB over other genes indicated that the main mechanism for resistance to tetracycline is by changes to the efflux pump. Our analysis of the types and proportion of tetracycline resistance genes in the Chanhe River at locations upstream and downstream of the urban center suggests that the increased number of tetracycline-resistant fecal coliforms and spatial variation of tetracycline resistance genes diversity were related to municipal wastewater treatment plant discharge.

  20. 33 CFR 159.123 - Coliform test: Type I devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coliform test: Type I devices. 159.123 Section 159.123 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.123 Coliform test...

  1. 33 CFR 159.126 - Coliform test: Type II devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coliform test: Type II devices. 159.126 Section 159.126 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.126 Coliform test...

  2. Quantification and identification of particle-associated bacteria in unchlorinated drinking water from three treatment plants by cultivation-independent methods.

    PubMed

    Liu, G; Ling, F Q; Magic-Knezev, A; Liu, W T; Verberk, J Q J C; Van Dijk, J C

    2013-06-15

    Water quality regulations commonly place quantitative limits on the number of organisms (e.g., heterotrophic plate count and coliforms) without considering the presence of multiple cells per particle, which is only counted as one regardless how many cells attached. Therefore, it is important to quantify particle-associated bacteria (PAB), especially cells per particle. In addition, PAB may house (opportunistic) pathogens and have higher resistance to disinfection than planktonic bacteria. It is essential to know bacterial distribution on particles. However, limited information is available on quantification and identification of PAB in drinking water. In the present study, PAB were sampled from the unchlorinated drinking water at three treatment plants in the Netherlands, each with different particle compositions. Adenosine triphosphate (ATP) and total cell counts (TCC) with flow cytometry were used to quantify the PAB, and high-throughput pyrosequencing was used to identify them. The number and activity of PAB ranged from 1.0 to 3.5 × 10(3) cells ml(-1) and 0.04-0.154 ng l(-1) ATP. There were between 25 and 50 cells found to be attached on a single particle. ATP per cell in PAB was higher than in planktonic bacteria. Among the identified sequences, Proteobacteria were found to be the most dominant phylum at all locations, followed by OP3 candidate division and Nitrospirae. Sequences related to anoxic bacteria from the OP3 candidate division and other anaerobic bacteria were detected. Genera of bacteria were found appear to be consistent with the major element composition of the associated particles. The presence of multiple cells per particle challenges the use of quantitative methods such as HPC and Coliforms that are used in the current drinking water quality regulations. The detection of anoxic and anaerobic bacteria suggests the ecological importance of PAB in drinking water distribution systems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Coliform and metal contamination in Lago de Colina, a recreational water body in Chihuahua State, Mexico.

    PubMed

    Rubio-Arias, Hector; Rey, Nora I; Quintana, Rey M; Nevarez, G Virginia; Palacios, Oskar

    2011-06-01

    Lago de Colina (Colina Lake) is located about 180 km south of the city of Chihuahua (Mexico), and during the Semana Santa (Holy Week) vacation period its recreational use is high. The objective of this study was to quantify coliform and heavy metal levels in this water body before and after the Holy Week vacation period in 2010. Twenty sampling points were randomly selected and two water samples were collected at each point near the surface (0.30 m) and at 1 m depth. After the Holy Week vacation the same twenty points were sampled at the same depths. Therefore, a total 80 water samples were analyzed for fecal and total coliforms and levels of the following metals: Al, As, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si and Zn. It was hypothesized that domestic tourism contaminated this water body, and as a consequence, could have a negative impact on visitor health. An analysis of variance (ANOVA) study was performed for each element and its interactions considering a factorial design where factor A was sample date and factor B was sample depth. Fecal coliforms were only detected at eight sampling points in the first week, but after Holy Week, both fecal and total coliforms were detected at most sampling points. The concentrations of Al, B, Na, Ni and Se were only statistically different for factor A. The levels of Cr, Cu, K and Mg was different for both date and depth, but the dual factor interaction was not significant. The amount of Ca and Zn was statistically different due to date, depth and their interaction. No significant differences were found for any factor or the interaction for the elements As, Fe and Mn. Because of the consistent results, it is concluded that local tourism is contaminating the recreational area of Colina Lake, Chihuahua, Mexico.

  4. Coliform and Metal Contamination in Lago de Colina, a Recreational Water Body in Chihuahua State, Mexico

    PubMed Central

    Rubio-Arias, Hector; Rey, Nora I.; Quintana, Rey M.; Nevarez, G. Virginia; Palacios, Oskar

    2011-01-01

    Lago de Colina (Colina Lake) is located about 180 km south of the city of Chihuahua (Mexico), and during the Semana Santa (Holy Week) vacation period its recreational use is high. The objective of this study was to quantify coliform and heavy metal levels in this water body before and after the Holy Week vacation period in 2010. Twenty sampling points were randomly selected and two water samples were collected at each point near the surface (0.30 m) and at 1 m depth. After the Holy Week vacation the same twenty points were sampled at the same depths. Therefore, a total 80 water samples were analyzed for fecal and total coliforms and levels of the following metals: Al, As, B, Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si and Zn. It was hypothesized that domestic tourism contaminated this water body, and as a consequence, could have a negative impact on visitor health. An analysis of variance (ANOVA) study was performed for each element and its interactions considering a factorial design where factor A was sample date and factor B was sample depth. Fecal coliforms were only detected at eight sampling points in the first week, but after Holy Week, both fecal and total coliforms were detected at most sampling points. The concentrations of Al, B, Na, Ni and Se were only statistically different for factor A. The levels of Cr, Cu, K and Mg was different for both date and depth, but the dual factor interaction was not significant. The amount of Ca and Zn was statistically different due to date, depth and their interaction. No significant differences were found for any factor or the interaction for the elements As, Fe and Mn. Because of the consistent results, it is concluded that local tourism is contaminating the recreational area of Colina Lake, Chihuahua, Mexico. PMID:21776236

  5. Land cover impacts on stream nutrients and fecal coliform in the lower Piedmont of West Georgia

    NASA Astrophysics Data System (ADS)

    Schoonover, Jon E.; Lockaby, B. Graeme

    2006-12-01

    SummaryAs urbanization infiltrates into rural areas, stream water quality is expected to decline as a result from increased impervious surface and greater sources for pollutants. Consequently, West Georgia's water quality is threatened by extensive development as well as other land uses such as livestock grazing and silvicultural activity. Maintenance of stream water quality, as land development occurs, is critical for the protection of drinking water and biotic integrity. A 2-phase, watershed-scale study was established to develop relationships among land cover and water quality within western Georgia. During phase 1, nutrient and fecal coliform data were collected within 18 mixed land use watersheds, ranging in size from 500 to 2500 ha. Regression models were developed that related land cover to stream water nutrient and fecal coliform concentrations. Nutrient and fecal coliform concentrations within watersheds having >24% impervious surface (IS) were often higher than those in nonurban watersheds (i.e., <5% IS) during both base flow (N: 1.64 mg/L versus 0.61 mg/L, and FC: 430 versus 120 MPN/100 ml) and storm flow (N: 1.93 mg/L versus 0.36 mg/L, and FC: 1600 versus 167 MPN/100 ml). Fecal coliform bacteria in urbanized areas consistently exceeded the US EPA's review criterion for recreational waters during both base flow and to a greater extent storm flow. During phase 2, regression models were tested based on data from six newly chosen watersheds with similar land use/cover patterns. Lastly, theoretical watersheds, based on land use percentages, were created to illustrate trends in water quality impairment as land development occurs. The models developed from this research could be used to forecast water quality changes under various land use scenarios in the developing Piedmont region of the US.

  6. Effect of cooled and chlorinated chiller water on Campylobacter and coliform counts on broiler carcasses during chilling at a middle-size poultry processing plant.

    PubMed

    Kameyama, Mitsuhiro; Chuma, Takehisa; Nishimoto, Tadahiro; Oniki, Hiroyuki; Yanagitani, Yasuo; Kanetou, Ryouichi; Gotou, Kouichi; Shahada, Francis; Iwata, Hiroyuki; Okamoto, Karoku

    2012-01-01

    To evaluate the effect of cooled and chlorinated chill water for Campylobacter and coliforms at a middle-size processing plant which was considered to be difficult for eliminate pathogenic bacteria on carcasses, following three conditions were examined; keeping temperature at < 20, < 10 and < 10°C, and chlorine concentration at < 50, < 50 and 50 to 70 ppm during processing in experiment 1, 2 and 3 respectively. Fifteen prechill and 15 postchill carcasses were examined in each experiment. In lower temperature of experiment 2, decreasing rate (%) of coliforms was significantly higher (P<0.01) than that in experiment 1. In higher chlorination of experiment 3, no Campylobacter was detected from all postchill carcasses.

  7. Water-quality assessment of the Ozark Plateaus study unit, Arkansas, Kansas, Missouri, and Oklahoma; nutrients, bacteria, organic carbon, and suspended sediment in surface water, 1993-95

    USGS Publications Warehouse

    Davis, Jerri V.; Bell, Richard W.

    1998-01-01

    Nutrient, bacteria, organic carbon, and suspended- sediment samples were collected from 1993-95 at 43 surface-water-quality sampling sites within the Ozark Plateaus National Water- Quality Assessment Program study unit. Most surface-water-quality sites have small or medium drainage basins, near-homogenous land uses (primarily agricultural or forest), and are located predominantly in the Springfield and Salem Plateaus. The water-quality data were analyzed using selected descriptive and statistical methods to determine factors affecting occurrence in streams in the study unit. Nitrogen and phosphorus fertilizer use increased in the Ozark Plateaus study unit for the period 1965-85, but the application rates are well below the national median. Fertilizer use differed substantially among the major river basins and physiographic areas in the study unit. Livestock and poultry waste is a major source of nutrient loading in parts of the study unit. The quantity of nitrogen and phosphorus from livestock and poultry wastes differed substantially among the river basins of the study unit's sampling network. Eighty six municipal sewage-treatment plants in the study unit have effluents of 0.5 million gallons per day or more (for the years 1985-91). Statistically significant differences existed in surface-water quality that can be attributed to land use, physiography, and drainage basin size. Dissolved nitrite plus nitrate, total phosphorus, fecal coliform bacteria, and dissolved organic carbon concentrations generally were larger at sites associated with agricultural basins than at sites associated with forested basins. A large difference in dissolved nitrite plus nitrate concentrations occurred between streams draining basins with agricultural land use in the Springfield and Salem Plateaus. Streams draining both small and medium agricultural basins in the Springfield Plateau had much larger concentrations than their counterparts in the Salem Plateau. Drainage basin size was not

  8. The health-related microbiological quality of bottled drinking water sold in Dar es Salaam, Tanzania.

    PubMed

    Kassenga, Gabriel R

    2007-03-01

    The consumption of bottled and plastic-bagged drinking water in Tanzania has increased largely because of the deteriorating quality of tap water. It is uncertain whether these water products are safe for drinking. In this study, the microbiological quality of bottled and plastic-bagged drinking water sold in Dar es Salaam, Tanzania, was investigated. One hundred and thirty samples representing 13 brands of bottled water collected from shops, supermarkets and street vendors were analysed for total coliform and faecal coliform organisms as well as heterotrophic bacteria. These were compared with 61 samples of tap water. Heterotrophic bacteria were detected in 92% of the bottled water samples analysed. Total and faecal coliform bacteria were present in 4.6% and 3.6%, respectively, of samples analysed with a tendency for higher contamination rates in plastic-bagged drinking water. Microbiological quality of tap water was found to be worse compared with bottled water, with 49.2% and 26.2% of sampling points showing the presence of total coliform and faecal coliform organisms, respectively. The results suggest caution and vigilance to avert outbreaks of waterborne diseases from these types of drinking water.

  9. FECAL COLIFORM INCREASE AFTER CENTRIFUGATION

    EPA Science Inventory

    The Water Environment Research Foundation (WERF) recently published a report titled Examination of Reactivation and Regrowth of Fecal Coliforms in Anaerobically Digested Sludges. Seven full-scale publicly owned treatment facilities were sampled several times to determine if bacte...

  10. Fermentation quality and in vitro methane production of sorghum silage prepared with cellulase and lactic acid bacteria

    PubMed Central

    Khota, Waroon; Pholsen, Suradej; Higgs, David; Cai, Yimin

    2017-01-01

    Objective The effects of lactic acid bacteria (LAB) and cellulase enzyme on fermentation quality, microorganism population, chemical composition and in vitro gas production of sorghum silages were studied. Methods Commercial inoculant Lactobacillus plantarum Chikuso 1 (CH), local selected strain Lactobacillus casei (L. casei) TH 14 and Acremonium cellulase (AC) were used as additives in sorghum silage preparation. Results Prior to ensiling Sorghum contained 104 LAB and 106 cfu/g fresh matter coliform bacteria. The chemical compositions of sorghum was 26.6% dry matter (DM), 5.2% crude protein (CP), and 69.7% DM for neutral detergent fiber. At 30 days of fermentation after ensiling, the LAB counts increased to a dominant population; the coliform bacteria and molds decreased to below detectable level. All sorghum silages were good quality with a low pH (<3.5) and high lactic acid content (>66.9 g/kg DM). When silage was inoculated with TH14, the pH value was significantly (p<0.05) lower and the CP content significantly (p<0.05) higher compared to control, CH and AC-treatments. The ratio of in vitro methane production to total gas production and DM in TH 14 and TH 14+AC treatments were significantly (p<0.05) reduced compared with other treatments while in vitro dry matter digestibility and gas production did not differ among treatments. Conclusion The results confirmed that L. casei TH14 could improve sorghum silage fermentation, inhibit protein degradation and decrease methane production. PMID:28728399

  11. Recurrence of fecal coliforms and Salmonella species in biosolids following thermophilic anaerobic digestion.

    PubMed

    Iranpour, Reza; Cox, Huub H J

    2006-09-01

    The U.S. Environmental Protection Agency (U.S. EPA) Part 503 Biosolids Rule requires the fecal coliform (indicator) or Salmonella species (pathogen) density requirements for Class A biosolids to be met at the last point of plant control (truck-loading facility and/or farm for land application). The three Southern Californian wastewater treatment plants in this study produced biosolids by thermophilic anaerobic digestion and all met the Class A limits for both fecal coliforms and Salmonella sp. in the digester outflow biosolids. At two plants, however, a recurrence of fecal coliforms was observed in postdigestion biosolids, which caused exceedance of the Class A limit for fecal coliforms at the truck-loading facility and farm for land application. Comparison of observations at the three plants and further laboratory tests indicated that the recurrence of fecal coliforms can possibly be related to the following combination of factors: (1) incomplete destruction of fecal coliforms during thermophilic anaerobic digestion, (2) contamination of Class A biosolids with fecal coliforms from external sources during postdigestion, (3) a large drop of the postdigestion biosolids temperature to below the maximum for fecal coliform growth, (4) an unknown effect of biosolids dewatering in centrifuges. At Hyperion Treatment Plant (City of Los Angeles, California), fecal coliform recurrence could be prevented by the following: (1) complete conversion to thermophilic operation to exclude contamination by mesophilically digested biosolids and (2) insulation and electrical heat-tracing of postdigestion train for maintaining a high biosolids temperature in postdigestion.

  12. The removal of thermo-tolerant coliform bacteria by immobilized waste stabilization pond algae.

    PubMed

    Pearson, H W; Marcon, A E; Melo, H N

    2011-01-01

    This study investigated the potential of laboratory- scale columns of immobilized micro-algae to disinfect effluents using thermo-tolerant coliforms (TTC) as a model system. Cells of a Chlorella species isolated from a waste stabilization pond complex in Northeast Brazil were immobilized in calcium alginate, packed into glass columns and incubated in contact with TTC suspensions for up to 24 hours. Five to six log removals of TTC were achieved in 6 hours and 11 log removals in 12 hours contact time. The results were similar under artificial light and shaded sunlight. However little or no TTC removal occurred in the light in columns of alginate beads without immobilized algae present or when the immobilized algae were incubated in the dark suggesting that the presence of both algae and light were necessary for TTC decay. There was a positive correlation between K(b) values for TTC and increasing pH in the effluent from the immobilized algal columns within the range pH 7.2 and 8.9. The potential of immobilized algal technology for wastewater disinfection may warrant further investigation.

  13. Coliform MPN counts of municipal raw sewage and sewage treatment plant in relation to the water of Buckingham Canal at Kalpakkam (Tamil Nadu, India).

    PubMed

    Kumar, A Yudhistra; Reddy, M Vikram

    2008-01-01

    Most Probable Number (MPN) of Total Coliforms (TC) and Faecal Coliforms (FC), and the physicochemical variables - temperature, Dissolved Oxygen (D.O.), Biochemical Oxygen Demand (B.O.D.), Chemical Oxygen Demand (C.O.D.), nitrates, phosphates and chlorides of municipal raw sewage and that of aeration tank and secondary clarifier of the Sewage Treatment Plant (STP), in relation to water at the treated sewage out-fall point, down-stream and up-stream of the Buckingham Canal at Kalpakkam were analyzed. Total Coliform and Faecal Coliform MPN counts were higher, 170 and 70/100 mL respectively in the raw sewage. However, the counts of the former in the aeration tank though remained similar, that of FC decreased to 50/100 mL; both of the counts further decreased to 30 and 44/100 mL respectively, in the secondary clarifier and were 110 and 23/100 mL, respectively at the treated sewage out-fall point in the canal. Total coliforms MPN was more than 18 times less in the water at the up-stream than that of the treated sewage out-fall point in the canal. Interestingly MPN of the FC in the up-stream water was nil while it was 8/100 mL in the canal's down-stream point. It is concluded that the FC, B.O.D., C.O.D., nitrates, phosphates and chlorides decreased and the D.O. increased in the treated-sewage due to the treatment of raw sewage through the STP.

  14. Bacterial recovery from breast skin of genetically feathered and featherless broiler carcasses immediately following scalding and picking.

    PubMed

    Buhr, R J; Berrang, M E; Cason, J A

    2003-10-01

    Genetically feathered and featherless sibling broilers selected for matched BW were killed, scalded, and defeathered to determine the consequences of feathers and empty feather follicles on the recovery of bacteria from carcass breast skin. In trial 1, the vents of all carcasses were plugged and sutured before scalding to prevent the expulsion of cloacal contents during picking. In trial 2, half of the carcasses had their vents plugged and sutured. Immediately after defeathering, breast skin was aseptically removed, and bacteria associated with it were enumerated. In trial 1, the levels of bacteria recovered did not differ between feathered and featherless carcasses: Campylobacter log10 1.4 cfu/mL of rinse, coliform log10 1.8, Escherichia coli log10 1.6, and total aerobic bacteria log10 3.1. In trial 2, the carcasses that had vents plugged and sutured had lower levels of all four types of bacteria (differences of Campylobacter log10 0.7 cfu/mL, coliform log10 1.8, E. coli log10 1.7, and total aerobic bacteria log10 0.5) than those carcasses with open vents. The lower levels of bacteria recovered from carcasses with the vents plugged and sutured during picking enabled detection of small but significant differences between feathered and featherless carcasses. The level of coliform and E. coli recovered was slightly higher by log10 0.7 cfu for feathered carcasses, but featherless carcasses had marginally higher levels of total aerobic bacteria by log10 0.4 cfu. Feathered and featherless carcasses with open vents during picking did not differ in the levels of recovery of coliform, E. coli, and total aerobic bacteria from breast skin.

  15. Characterization of bacterial coliform occurrences in different zones of a drinking water distribution system.

    PubMed

    Blanch, A R; Galofré, B; Lucena, F; Terradillos, A; Vilanova, X; Ribas, F

    2007-03-01

    To compare the bacterial coliforms detected from occurrences in three zones of a water distribution system supplied by two separate water sources. Conventional and standardized protocols for identifying enterobacterial populations were applied. Additional tests to confirm isolates were included. Analyses of diversity and population similarity were performed using the Phene Plate System, a miniaturized biochemical phenotyping method. Isolates were identified by the API 20E system in tandem with biochemical phenotyping. A total of 16 576 samples were taken from the water distribution system, with 1416 isolates analysed. A low number of coliform occurrences were observed (2%). Escherichia coli was not detected in either water origin or in Zone 2 samples; however, in Zones 1 and 3 a low number of cases of E. coli were recorded. The percentages of E. coli depended on the identification criteria. Eight biochemical profiles for coliform populations were defined according to the results of the confirmative tests. There was a high diversity among these populations in the three zones studied, although no significant variations in their composition (associated with occurrences in the different zones) were observed. Klebsiella oxytoca was the most commonly detected species irrespective of zone, although seven other enterobacterial genera were also found. Analysis of the enzymatic activity of beta-glucuronidase or application of the criteria established in the norm ISO 9308-1, in tandem with thermotolerance was needed to evaluate the occurrence of E. coli in the distribution systems. Detected occurrences of bacterial coliforms could be associated with re-growth patterns for specific sampling points in the distribution system. Seasonal differences, independent of the studied zones, were observed. Biochemical phenotyping of bacterial coliforms was shown to be a useful method on the characterization of occurrences in water distribution systems.

  16. Indicator bacteria and associated water quality constituents in stormwater and snowmelt from four urban catchments

    NASA Astrophysics Data System (ADS)

    Galfi, H.; Österlund, H.; Marsalek, J.; Viklander, M.

    2016-08-01

    Four indicator bacteria were measured in association with physico-chemical constituents and selected inorganics during rainfall, baseflow and snowmelt periods in storm sewers of four urban catchments in a northern Swedish city. The variation patterns of coliforms, Escherichia coli, enterococci and Clostridium perfringens concentrations were assessed in manually collected grab samples together with those of phosphorus, nitrogen, solids, and readings of pH, turbidity, water conductivity, temperature and flow rates to examine whether these constituents could serve as potential indicators of bacteria sources. A similar analysis was applied to variation patterns of eight selected inorganics typical for baseflow and stormwater runoff to test the feasibility of using these inorganics to distinguish between natural and anthropogenic sources of inflow into storm sewers. The monitored catchments varied in size, the degree of development, and land use. Catchment and season (i.e., rainy or snowmelt periods) specific variations were investigated for sets of individual stormwater samples by the principal component analysis (PCA) to identify the constituents with variation patterns similar to those of indicator bacteria, and to exclude the constituents with less similarity. In the reduced data set, the similarities were quantified by the clustering correlation analysis. Finally, the positive/negative relationships found between indicator bacteria and the identified associated constituent groups were described by multilinear regressions. In the order of decreasing concentrations, coliforms, E. coli and enterococci were found in the highest mean concentrations during both rainfall and snowmelt generated runoff. Compared to dry weather baseflow, concentrations of these three indicators in stormwater were 10 (snowmelt runoff) to 102 (rain runoff) times higher. C. perfringens mean concentrations were practically constant regardless of the season and catchment. The type and number of

  17. Coliform Bacteria as Indicators of Diarrheal Risk in Household Drinking Water: Systematic Review and Meta-Analysis

    PubMed Central

    Gruber, Joshua S.; Ercumen, Ayse; Colford, John M.

    2014-01-01

    Background Current guidelines recommend the use of Escherichia coli (EC) or thermotolerant (“fecal”) coliforms (FC) as indicators of fecal contamination in drinking water. Despite their broad use as measures of water quality, there remains limited evidence for an association between EC or FC and diarrheal illness: a previous review found no evidence for a link between diarrhea and these indicators in household drinking water. Objectives We conducted a systematic review and meta-analysis to update the results of the previous review with newly available evidence, to explore differences between EC and FC indicators, and to assess the quality of available evidence. Methods We searched major databases using broad terms for household water quality and diarrhea. We extracted study characteristics and relative risks (RR) from relevant studies. We pooled RRs using random effects models with inverse variance weighting, and used standard methods to evaluate heterogeneity and publication bias. Results We identified 20 relevant studies; 14 studies provided extractable results for meta-analysis. When combining all studies, we found no association between EC or FC and diarrhea (RR 1.26 [95% CI: 0.98, 1.63]). When analyzing EC and FC separately, we found evidence for an association between diarrhea and EC (RR: 1.54 [95% CI: 1.37, 1.74]) but not FC (RR: 1.07 [95% CI: 0.79, 1.45]). Across all studies, we identified several elements of study design and reporting (e.g., timing of outcome and exposure measurement, accounting for correlated outcomes) that could be improved upon in future studies that evaluate the association between drinking water contamination and health. Conclusions Our findings, based on a review of the published literature, suggest that these two coliform groups have different associations with diarrhea in household drinking water. Our results support the use of EC as a fecal indicator in household drinking water. PMID:25250662

  18. Coliform bacteria as indicators of diarrheal risk in household drinking water: systematic review and meta-analysis.

    PubMed

    Gruber, Joshua S; Ercumen, Ayse; Colford, John M

    2014-01-01

    Current guidelines recommend the use of Escherichia coli (EC) or thermotolerant ("fecal") coliforms (FC) as indicators of fecal contamination in drinking water. Despite their broad use as measures of water quality, there remains limited evidence for an association between EC or FC and diarrheal illness: a previous review found no evidence for a link between diarrhea and these indicators in household drinking water. We conducted a systematic review and meta-analysis to update the results of the previous review with newly available evidence, to explore differences between EC and FC indicators, and to assess the quality of available evidence. We searched major databases using broad terms for household water quality and diarrhea. We extracted study characteristics and relative risks (RR) from relevant studies. We pooled RRs using random effects models with inverse variance weighting, and used standard methods to evaluate heterogeneity and publication bias. We identified 20 relevant studies; 14 studies provided extractable results for meta-analysis. When combining all studies, we found no association between EC or FC and diarrhea (RR 1.26 [95% CI: 0.98, 1.63]). When analyzing EC and FC separately, we found evidence for an association between diarrhea and EC (RR: 1.54 [95% CI: 1.37, 1.74]) but not FC (RR: 1.07 [95% CI: 0.79, 1.45]). Across all studies, we identified several elements of study design and reporting (e.g., timing of outcome and exposure measurement, accounting for correlated outcomes) that could be improved upon in future studies that evaluate the association between drinking water contamination and health. Our findings, based on a review of the published literature, suggest that these two coliform groups have different associations with diarrhea in household drinking water. Our results support the use of EC as a fecal indicator in household drinking water.

  19. Fast coliform detection in portable microbe enrichment unit (PMEU) with Colilert(®) medium and bubbling.

    PubMed

    Hakalehto, Elias; Heitto, Anneli; Heitto, Lauri

    2013-09-01

    Laboratory strains of coliforms Escherichia coli and Klebsiella mobilis were used to artificially contaminate water samples in two different cultivation and detection systems, without and with bubble flow. Samples were collected with an automated system (ASCS). The positive coliform signal caused the color change into yellow (at 550-570nm). This signal could also be transmitted on-line to cell phones. E. coli containing samples emitted UV fluorescence at 480-560nm when activated by UV light. If cultivation was started with inocula varying from 10,000 to 1cfu/ml, the positive detection was obtained between 2 and 18h, respectively, in Colilert medium using Coline PMEU device without gas bubbling. Accordingly, a single K. mobilis cell produced detectable growth in 18h. Various clinical E. coli strains were compared to each other with equal inoculum sizes, and they showed slight variations in the initiation and speed of growth. The gas bubble flow in PMEU Spectrion promoted the mixing and interaction of bacteria and indicator media and speeded the onset of growth. Carbon dioxide also accelerated bacterial growth. In the presence of vancomycin, the onset of E. coli culture growth was speeded up by the volatile outlet flow from previous cultures. In the last cultivation syringe in a series of five, the lag phase disappeared and the growth of the inoculum continued without major interruption. the stimulation of the cultures by the gas flow turned out to be a useful means for improving the detection of indicator bacteria. It could also be used in combination with antibiotic selection in the broth medium. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. THE TOTAL LUMINOUS EFFICIENCY OF LUMINOUS BACTERIA

    PubMed Central

    Harvey, E. Newton

    1925-01-01

    emits 14 lumen-seconds per mg. O2 absorbed. Since the maximum lumens per watt are 640, representing 100 per cent efficiency, the total luminous efficiency if .00156. As some of the oxygen is used in respiratory oxidation which may have nothing to do with luminescence, the luminescence efficiency must be higher than 1 lumen per watt. Experiments with KCN show that this substance may reduce the oxygen consumption to 1/20 of its former value while reducing the luminescence intensity only ¼. A partial separation of respiratory from luminescence oxidations is therefore effected by KCN, and our efficiency becomes 5 lumens per watt, or .0078. This is an over-all efficiency, based on the energy value of the "fuel" of the bacteria, regarded as a power plant for producing light. It compares very favorably with the 1.6 lumens per watt of a tungsten vacuum lamp or the 3.9 lumens per watt of a tungsten nitrogen lamp, if we correct the usual values for these illuminants, based on watts at the lamp terminals, for a 20 per cent efficiency of the power plant converting the energy of coal fuel into electric current. The specific luminous emission of the bacteria is 3.14 x 10–6 lumens per cm2. One bacterium absorbs 215,000 molecules of oxygen per second and emits 1,280 quanta of light at λmax = 510µµ. If we suppose that a molecule of oxygen uniting with luminous material gives rise to the emission of 1 quantum of light energy, only 1/168 of the oxygen absorbed is used in luminescence. On this basis the efficiency becomes 168 lumens per watt or 26.2 per cent. PMID:19872192

  1. WATER FROM DIFFERENT SOURCES USED FOR THE IRRIGATION OF VEGETABLES TO BE MARKETED: RESEARCH ON Cryptosporidium spp., Giardia spp., AND COLIFORMS IN PARANA, BRAZIL.

    PubMed

    Tiyo, Rogerio; de Souza, Carla Zangari; Nishi, Letícia; Brustolin, Camila Fernanda; Ratti, Bianca Altrão; Falavigna Guilherme, Ana Lucia

    2015-01-01

    The aim of this work was to compare, from a parasitological ( Cryptosporidium spp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidium spp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardia spp. or Cryptosporidium spp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidium spp. and Giardia spp., as well as artesian wells for coliform control in local production of vegetables to be marketed.

  2. WATER FROM DIFFERENT SOURCES USED FOR THE IRRIGATION OF VEGETABLES TO BE MARKETED: RESEARCH ON Cryptosporidium spp., Giardia spp., AND COLIFORMS IN PARANA, BRAZIL

    PubMed Central

    TIYO, Rogerio; de SOUZA, Carla Zangari; NISHI, Letícia; BRUSTOLIN, Camila Fernanda; RATTI, Bianca Altrão; FALAVIGNA GUILHERME, Ana Lucia

    2015-01-01

    SUMMARY The aim of this work was to compare, from a parasitological ( Cryptosporidiumspp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidiumspp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardiaspp. or Cryptosporidiumspp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidiumspp. and Giardiaspp., as well as artesian wells for coliform control in local production of vegetables to be marketed. PMID:26422158

  3. Evaluation of Water Quality for Two St. Johns River Tributaries Receiving Septic Tank Effluent, Duval County, Florida

    USGS Publications Warehouse

    Wicklein, Shaun M.

    2004-01-01

    Tributary streamflow to the St. Johns River in Duval County is thought to be affected by septic tank leachate from residential areas adjacent to these tributaries. Water managers and the city of Jacksonville have committed to infrastructure improvements as part of a management plan to address the impairment of tributary water quality. In order to provide data to evaluate the effects of future remedial activities in selected tributaries, major ion and nutrient concentrations, fecal coliform concentrations, detection of wastewater compounds, and tracking of bacterial sources were used to document septic tank influences on the water quality of selected tributaries. The tributaries Fishing Creek and South Big Fishweir Creek were selected because they drain subdivisions identified as high priority locations for septic tank phase-out projects: the Pernecia and Murray Hill B subdivisions, respectively. Population, housing (number of residences), and septic tank densities for the Murray Hill B subdivision are greater than those for the Pernecia subdivision. Water-quality samples collected in the study basins indicate influences from ground water and septic tanks. Estimated concentrations of total nitrogen ranged from 0.33 to 2.86 milligrams per liter (mg/L), and ranged from less than laboratory reporting limit (0.02 mg/L) to 0.64 mg/L for total phosphorus. Major ion concentrations met the State of Florida Class III surface-water standards; total nitrogen and total phosphorus concentrations exceeded the U.S. Environmental Protection Agency Ecoregion XII nutrient criteria for rivers and streams 49 and 96 percent of the time, respectively. Organic wastewater compounds detected at study sites were categorized as detergents, antioxidants and flame retardants, manufactured polycarbonate resins, industrial solvents, and mosquito repellent. The most commonly detected compound was para-nonylphenol, a breakdown product of detergent. Results of wastewater sampling give evidence that

  4. A study of fecal coliform sources at a coastal site using colored dissolved organic matter (CDOM) as a water source tracer.

    PubMed

    Clark, Catherine D; O'Connor, Adam P; Foley, Denise M; de Bruyn, Warren J

    2007-09-01

    Optical properties of colored dissolved organic matter (CDOM) were measured as a tracer of polluted waters in a Southern California surf-zone with consistently high levels of fecal indicator bacteria. Salinity, temperature, fecal coliform, absorbance (200-700nm) and fluorescence (lambda(excitation)=350nm; lambda(emission)=360-650nm) were measured in the creek and surf-zone during a dry and rain event. Fluorescence to absorption ratios for CDOM were used to distinguish water masses, with two distinct CDOM end-members identified as creek (flu/abs=8.7+/-0.8x10(4)) and coastal (flu/abs=2.2+/-0.3x10(4)). Waters containing the same CDOM end-member had highly variable bacterial levels during the dry event, suggesting intermittent sources of bacteria added to a uniform water source, consistent with marine birds. During the rain event, increased levels of the creek end-member and bacteria indicated a second bacteria source from runoff.

  5. 40 CFR 141.859 - Coliform treatment technique triggers and assessment requirements for protection against...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...

  6. 40 CFR 141.859 - Coliform treatment technique triggers and assessment requirements for protection against...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... per month, the system has two or more total coliform-positive samples in the same month. (iii) The... second Level 1 trigger as defined in paragraph (a)(1) of this section, within a rolling 12-month period...) Level 1 treatment technique triggers. (i) For systems taking 40 or more samples per month, the system...

  7. Assessment of the climate change impacts on fecal coliform contamination in a tidal estuarine system.

    PubMed

    Liu, Wen-Cheng; Chan, Wen-Ting

    2015-12-01

    Climate change is one of the key factors affecting the future microbiological water quality in rivers and tidal estuaries. A coupled 3D hydrodynamic and fecal coliform transport model was developed and applied to the Danshuei River estuarine system for predicting the influences of climate change on microbiological water quality. The hydrodynamic and fecal coliform model was validated using observational salinity and fecal coliform distributions. According to the analyses of the statistical error, predictions of the salinity and the fecal coliform concentration from the model simulation quantitatively agreed with the observed data. The validated model was then applied to predict the fecal coliform contamination as a result of climate change, including the change of freshwater discharge and the sea level rise. We found that the reduction of freshwater discharge under climate change scenarios resulted in an increase in the fecal coliform concentration. The sea level rise would decrease fecal coliform distributions because both the water level and the water volume increased. A reduction in freshwater discharge has a negative impact on the fecal coliform concentration, whereas a rising sea level has a positive influence on the fecal coliform contamination. An appropriate strategy for the effective microbiological management in tidal estuaries is required to reveal the persistent trends of climate in the future.

  8. Classification of Antibiotic Resistance Patterns of Indicator Bacteria by Discriminant Analysis: Use in Predicting the Source of Fecal Contamination in Subtropical Waters

    PubMed Central

    Harwood, Valerie J.; Whitlock, John; Withington, Victoria

    2000-01-01

    The antibiotic resistance patterns of fecal streptococci and fecal coliforms isolated from domestic wastewater and animal feces were determined using a battery of antibiotics (amoxicillin, ampicillin, cephalothin, chlortetracycline, oxytetracycline, tetracycline, erythromycin, streptomycin, and vancomycin) at four concentrations each. The sources of animal feces included wild birds, cattle, chickens, dogs, pigs, and raccoons. Antibiotic resistance patterns of fecal streptococci and fecal coliforms from known sources were grouped into two separate databases, and discriminant analysis of these patterns was used to establish the relationship between the antibiotic resistance patterns and the bacterial source. The fecal streptococcus and fecal coliform databases classified isolates from known sources with similar accuracies. The average rate of correct classification for the fecal streptococcus database was 62.3%, and that for the fecal coliform database was 63.9%. The sources of fecal streptococci and fecal coliforms isolated from surface waters were identified by discriminant analysis of their antibiotic resistance patterns. Both databases identified the source of indicator bacteria isolated from surface waters directly impacted by septic tank discharges as human. At sample sites selected for relatively low anthropogenic impact, the dominant sources of indicator bacteria were identified as various animals. The antibiotic resistance analysis technique promises to be a useful tool in assessing sources of fecal contamination in subtropical waters, such as those in Florida. PMID:10966379

  9. Fecal coliform accumulation within a river subject to seasonally-disinfected wastewater discharges.

    PubMed

    Mitch, Azalea A; Gasner, Katherine C; Mitch, William A

    2010-09-01

    As pathogen contamination is a leading cause of surface water impairment, there has been increasing interest in the implications of seasonal disinfection practices of wastewater effluents for meeting water quality goals. For receiving waters designated for recreational use, disinfection during the winter months is often considered unnecessary due to reduced recreational usage, and assumptions that lower temperatures may reduce pathogen accumulation. For a river subject to seasonal disinfection, we sought to evaluate whether fecal coliforms accumulate during the winter to concentrations that would impair river water quality. Samples were collected from municipal wastewater outfalls along the river, as well as upstream and downstream of each outfall during the winter, when disinfection is not practiced, and during the summer, when disinfection is practiced. During both seasons, fecal coliform concentrations reached 2000-5000 CFU/100 mL, nearly an order of magnitude higher than levels targeted for the river to achieve primary contact recreational uses. During the summer, wastewater effluents were not significant contributors to fecal coliform loadings to the river. During the winter, fecal coliform accumulated along the river predominantly due to loadings from successive wastewater outfalls. In addition to the exceedance of fecal coliform criteria within the river, the accumulation of wastewater-derived fecal coliform along the river during the winter season suggests that wastewater outfalls may contribute elevated loads of pathogens to the commercial shellfish operations occurring at the mouth of the river. Reductions in fecal coliform concentrations between wastewater outfalls were attributed to dilution or overall removal. Combining discharge measurements from gauging stations, tributaries and wastewater outfalls to estimate seepage, dilution between wastewater outfalls was estimated, along with the percentage of the river deriving from wastewater outfalls. After

  10. [Occurrence of bacteria of the Yersinia genus in surface water].

    PubMed

    Krogulska, B; Maleszewska, J

    1992-01-01

    The aim of the study was determination of the frequency of occurrence of Yersinia genus bacteria in surface waters polluted to various degrees with bacteria of the coliform and of fecal coli. For detection of Yersinia rods the previously elaborated medium Endo MLCe and the membrane filter method were applied. Samples of 42 surface waters were examined, including 26 from rivers and 16 from lakes, ponds and clay-pits. On the basis of sanitary bacteriological analysis 16 surface waters were classified to class I purity, 10 to class II, the remaining ones to class III or beyond classification. Yersinia rods were detected in 15 water bodies that is 35.7% of the examined waters. A total of 27 Yersinia strains were identified with dominance of Y. intermedia (14 strains) and Y. enterocolitica (10 strains). Three strains represented by the species Yersinia frederiksenii. Most of the Y. enterocolitica strains belonged to biotype 1, the particular strains being represented by various serotypes. Hence their different origin may be concluded. The pathogenic serotypes 0:3 and 0:9 of Yersinia enterocolitica were not detected.

  11. Detection of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa)

    NASA Astrophysics Data System (ADS)

    Ekawati, ER; Yusmiati, S. N. H.

    2018-01-01

    Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was < 5 x 105 colony/g sample.

  12. Survival of fecal coliforms in dry-composting toilets.

    PubMed

    Redlinger, T; Graham, J; Corella-Barud, V; Avitia, R

    2001-09-01

    The dry-composting toilet, which uses neither water nor sewage infrastructure, is a practical solution in areas with inadequate sewage disposal and where water is limited. These systems are becoming increasingly popular and are promoted to sanitize human excreta and to recycle them into fertilizer for nonedible plants, yet there are few data on the safety of this technology. This study analyzed fecal coliform reduction in approximately 90 prefabricated, dry-composting toilets (Sistema Integral de Reciclamiento de Desechos Orgánicos [SIRDOs]) that were installed on the U.S.-Mexico border in Ciudad Juárez, Chihuahua, Mexico. The purpose of this study was to determine fecal coliform reduction over time and the most probable method of this reduction. Biosolid waste samples were collected and analyzed at approximately 3 and 6 months and were classified based on U.S. Environmental Protection Agency standards. Results showed that class A compost (high grade) was present in only 35.8% of SIRDOs after 6 months. The primary mechanism for fecal coliform reduction was found to be desiccation rather than biodegradation. There was a significant correlation (P = 0.008) between classification rating and percent moisture categories of the biosolid samples: drier samples had a greater proportion of class A samples. Solar exposure was critical for maximal class A biosolid end products (P = 0.001). This study only addressed fecal coliforms as an indicator organism, and further research is necessary to determine the safety of composting toilets with respect to other pathogenic microorganisms, some of which are more resistant to desiccation.

  13. Survival of Fecal Coliforms in Dry-Composting Toilets

    PubMed Central

    Redlinger, Thomas; Graham, Jay; Corella-Barud, Verónica; Avitia, Raquel

    2001-01-01

    The dry-composting toilet, which uses neither water nor sewage infrastructure, is a practical solution in areas with inadequate sewage disposal and where water is limited. These systems are becoming increasingly popular and are promoted to sanitize human excreta and to recycle them into fertilizer for nonedible plants, yet there are few data on the safety of this technology. This study analyzed fecal coliform reduction in approximately 90 prefabricated, dry-composting toilets (Sistema Integral de Reciclamiento de Desechos Orgánicos [SIRDOs]) that were installed on the U.S.-Mexico border in Ciudad Juárez, Chihuahua, Mexico. The purpose of this study was to determine fecal coliform reduction over time and the most probable method of this reduction. Biosolid waste samples were collected and analyzed at approximately 3 and 6 months and were classified based on U.S. Environmental Protection Agency standards. Results showed that class A compost (high grade) was present in only 35.8% of SIRDOs after 6 months. The primary mechanism for fecal coliform reduction was found to be desiccation rather than biodegradation. There was a significant correlation (P = 0.008) between classification rating and percent moisture categories of the biosolid samples: drier samples had a greater proportion of class A samples. Solar exposure was critical for maximal class A biosolid end products (P = 0.001). This study only addressed fecal coliforms as an indicator organism, and further research is necessary to determine the safety of composting toilets with respect to other pathogenic microorganisms, some of which are more resistant to desiccation. PMID:11526002

  14. Presence of Pathogenic Bacteria and Viruses in the Daycare Environment.

    PubMed

    Ibfelt, Tobias; Engelund, Eva Hoy; Permin, Anders; Madsen, Jonas Stenløkke; Schultz, Anna Charlotte; Andersen, Leif Percival

    2015-10-01

    The number of children in daycare centers (DCCs) is rising. This increases exposure to microorganisms and infectious diseases. Little is known about which bacteria and viruses are present in the DCC environment and where they are located. In the study described in this article, the authors set out to determine the prevalence of pathogenic bacteria and viruses and to find the most contaminated fomites in DCCs. Fifteen locations in each DCC were sampled for bacteria, respiratory viruses, and gastrointestinal viruses. The locations were in the toilet, kitchen, and playroom areas and included nursery pillows, toys, and tables, among other things. Coliform bacteria were primarily found in the toilet and kitchen areas whereas nasopharyngeal bacteria were found mostly on toys and fabric surfaces in the playroom. Respiratory viruses were omnipresent in the DCC environment, especially on the toys.

  15. Limnological Monitoring on the Upper Mississippi River System, 1993-1996: Long Term Resource Monitoring Program Havana Field Station

    DTIC Science & Technology

    2002-11-01

    synopsis of the collected data and collection methods, as well as a preliminary report of remarkable or unusual conditions in the system. They are intended...resource requires scientific understanding of the ecosystem and of its long-term trends and conditions . To meet this need, Congress authorized a Long...chemical oxygen demand, biochemical oxygen demand, total coliform bacteria , fecal coliform bacteria , fecal streptococcus, heavy metals, pesticides, and

  16. Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants

    NASA Technical Reports Server (NTRS)

    Munoz, E. F.; Silverman, M. P.

    1979-01-01

    A single-step most-probable-number method for determining the number of fecal coliform bacteria present in sewage treatment plant effluents is discussed. A single growth medium based on that of Reasoner et al. (1976) and consisting of 5.0 gr. proteose peptone, 3.0 gr. yeast extract, 10.0 gr. lactose, 7.5 gr. NaCl, 0.2 gr. sodium lauryl sulfate, and 0.1 gr. sodium desoxycholate per liter is used. The pH is adjusted to 6.5, and samples are incubated at 44.5 deg C. Bacterial growth is detected either by measuring the increase with time in the electrical impedance ratio between the innoculated sample vial and an uninnoculated reference vial or by visual examination for turbidity. Results obtained by the single-step method for chlorinated and unchlorinated effluent samples are in excellent agreement with those obtained by the standard method. It is suggested that in automated treatment plants impedance ratio data could be automatically matched by computer programs with the appropriate dilution factors and most probable number tables already in the computer memory, with the corresponding result displayed as fecal coliforms per 100 ml of effluent.

  17. Chemical characteristic of salt fermented meat inoculated with Pediococcus ssp

    NASA Astrophysics Data System (ADS)

    Pramono, Y. B.; Rahayu, E. S.; Suparmo; Utami, T.; Nurwantoro; Yunianto, V. D.

    2018-01-01

    The research goal is knowing of the characteristict of salt fermented meat by Pediococcus ssp. There were microbiological, chemical, and off-flavor compound during fermentation. This study was conducted on research of influence of salt-meat fermentation inoculated used starter. They were included microbiological characteristics, and chemical characteristics. Microbiological characteristics observed were total bacteria, number of coliform groups, bacteria producing bioamine, and total lactic acid bacteria. The result showed that decreasing of coliform and bioamine producer bacteria, and total lactic acid bacteria decreased 3 log cycle. While the soluble protein increased of 7-8% and bioamine increased of 5-6 mg/100 g. And then Off-flavour compound, TVN and TMA increased of 36-20 mg/100g and 16-30 mg/100g, respectively. Conclusion of the research that Pedioccoccus ssp. influenced salt fermented meat.

  18. Disinfection of bacteria attached to granular activated carbon.

    PubMed Central

    LeChevallier, M W; Hassenauer, T S; Camper, A K; McFeters, G A

    1984-01-01

    Heterotrophic plate count bacteria, coliform organisms, and pathogenic microorganisms attached to granular activated carbon particles were examined for their susceptibility to chlorine disinfection. When these bacteria were grown on carbon particles and then disinfected with 2.0 mg of chlorine per liter (1.4 to 1.6 mg of free chlorine residual per liter after 1 h) for 1 h, no significant decrease in viable counts was observed. Washed cells attached to the surface of granular activated carbon particles showed similar resistance to chlorine, but a progressive increase in sublethal injury was found. Observations made by scanning electron microscope indicated that granular activated carbon was colonized by bacteria which grow in cracks and crevices and are coated by an extracellular slime layer. These data suggest a possible mechanism by which treatment and disinfection barriers can be penetrated and pathogenic bacteria may enter drinking water supplies. Images PMID:6508306

  19. Immunologic Interrelationships of Coliform Heat-Labile and Heat-Stable Enterotoxins

    DTIC Science & Technology

    1979-01-15

    Animal, Resources, National Academy of Sciences National Research Council. -. - L S~- A - - -7- PUBLICATIONS 1. Klipstein FA, Engert RF: Immunological... Engert RF: Immunological relationship of different preparations of coliform enterotoxins. Infec Immun 21:771, 1978 3. Klipstein FA, Engert RF...Reversal of jejunal water secretion by glucose in rats exposed to coliform enterotoxins. Gastroenterology 75:255, 1978 4. Klipstein FA, Rowe B, Engert RF

  20. Septage treatments to reduce the numbers of bacteria and polioviruses.

    PubMed Central

    Stramer, S L; Cliver, D O

    1984-01-01

    Disposal of the pumped contents of septic tanks (septage) represents a possible means of dissemination of enteric pathogens including viruses, since persistence of enteroviruses in septic tank sludge for greater than 100 days has been demonstrated. The risk of exposure to potentially infectious agents can be reduced by disinfecting septages before their disposal. Of the septage disinfectants examined (technical and analytical grade glutaraldehyde, hydrogen peroxide, heat treatments, and a combination of heat and hydrogen peroxide), the treatment including hydrogen peroxide (5 mg, plus 0.33 mg of trichloroacetic acid, per ml of septage) and 55 degrees C killed virtually all the bacteria in septage within 1 h, whereas 55 degrees C alone inactivated inoculated polioviruses within 30 min. Virus was the most sensitive to heat, whereas fecal coliforms appeared to be the most sensitive to all chemical treatments. The responses of fecal streptococci and virus to both grades of glutaraldehyde (each at 1 mg/ml) were similar. Virus was more resistant than either fecal streptococci or total bacteria to low concentrations of hydrogen peroxide (1 to 5 mg/ml); however, virus and fecal streptococci were more labile than total bacteria to the highest peroxide concentration (10 mg/ml) examined. It is possible that the treatment combining heat and hydrogen peroxide was the most effective in reducing the concentrations of all bacteria, because catalase and peroxidases as well as other enzymes were heat inactivated, although catalase seems the most likely cause of damage. However, this most effective treatment does not appear to be practical for on-site use as performed, so further work on septage disinfection is recommended. PMID:6093691

  1. Effect of dredge spoil deposition on fecal coliform counts in sediments at a disposal site.

    PubMed Central

    Babinchak, J A; Graikoski, J T; Dudley, S; Nitkowski, M F

    1977-01-01

    The most-probable-number of fecal coliforms in sediments was monitored at the New London dump site in Long Island Sound during the deposition of dredge spoil from the Thames River. Although the geometric mean for fecal coliforms at five stations in the river was 14,000/100 ml before dredging commenced, the deposition of this material did not increase the incidence of fecal coliforms at 17 spoil stations and 13 control stations in the disposal and surrounding areas. Fecal coliforms appear to occur only in the surface sediment material and are diluted by the subsurface material during the dredging operation. Fecal coliform analyses of bottom waters during high and low tides indicated that the flow of water from the Thames River played a major role in determining the most-probable-number of fecal coliforms in the sediments at the disposal site. PMID:329761

  2. Water-Quality Changes Caused by Riverbank Filtration Between the Missouri River and Three Pumping Wells of the Independence, Missouri, Well Field 2003-05

    USGS Publications Warehouse

    Kelly, Brian P.; Rydlund, Jr., Paul H.

    2006-01-01

    Riverbank filtration substantially improves the source-water quality of the Independence, Missouri well field. Coliform bacteria, Cryptosporidium, Giardia, viruses and selected constituents were analyzed in water samples from the Missouri River, two vertical wells, and a collector well. Total coliform bacteria, Cryptosporidium, Giardia, and total culturable viruses were detected in the Missouri River, but were undetected in samples from wells. Using minimum reporting levels for non-detections in well samples, minimum log removals were 4.57 for total coliform bacteria, 1.67 for Cryptosporidium, 1.67 for Giardia, and 1.15 for total culturable virus. Ground-water flow rates between the Missouri River and wells were calculated from water temperature profiles and ranged between 1.2 and 6.7 feet per day. Log removals based on sample pairs separated by the traveltime between the Missouri River and wells were infinite for total coliform bacteria (minimum detection level equal to zero), between 0.8 and 3.5 for turbidity, between 1.5 and 2.1 for Giardia, and between 0.4 and 2.6 for total culturable viruses. Cryptosporidium was detected once in the Missouri River but no corresponding well samples were available. No clear relation was evident between changes in water quality in the Missouri River and in wells for almost all constituents. Results of analyses for organic wastewater compounds and the distribution of dissolved oxygen, specific conductance, and temperature in the Missouri River indicate water quality on the south side of the river was moderately influenced by the south bank inflows to the river upstream from the Independence well field.

  3. Fecal-indicator bacteria concentrations in the Illinois River between Hennepin and Peoria, Illinois: 2007-08

    USGS Publications Warehouse

    Dupre, David H.; Hortness, Jon E.; Terrio, Paul J.; Sharpe, Jennifer B.

    2012-01-01

    The Illinois Environmental Protection Agency has designated portions of the Illinois River in Peoria, Woodford, and Tazewell Counties, Illinois, as impaired owing to the presence of fecal coliform bacteria. The U.S. Geological Survey, in cooperation with the Tri-County Regional Planning Commission, examined the water quality in the Illinois River and major tributaries within a 47-mile reach between Peoria and Hennepin, Ill., during water year 2008 (October 2007–September 2008). Investigations included synoptic (snapshot) sampling at multiple locations in a 1-day period: once in October 2007 during lower streamflow conditions, and again in June 2008 during higher streamflow conditions. Five locations in the study area were monitored for the entire year at monthly or more frequent intervals. Two indicator bacteria were analyzed in each water sample: fecal coliform and Escherichia coli (E. coli). Streamflow information from previously established monitoring locations in the study area was used in the analysis. Correlation analyses were used to characterize the relation between the two fecal-indicator bacteria and the relation of either indicator to streamflow. Concentrations of the two measured fecal-indicator bacteria correlated well for all samples analyzed (r = 0.94, p E. coli: rho = -0.43, p = 0.0157). The correlation between fecal indicators and streamflow in tributaries or in the Illinois River at Hennepin was found to be statistically significant, yet moderate in strength with coefficient values ranging from r = 0.4 to 0.6. Indirect observations from the June 2008 higher flow synoptic event may indicate continued effects from combined storm and sanitary sewers in the vicinity of the Illinois River near Peoria, Ill., contributing to observed single-sample exceedance of the State criterion for fecal coliform.

  4. Fecal-indicator bacteria in streams alonga gradient of residential development

    USGS Publications Warehouse

    Frenzel, Steven A.; Couvillion, Charles S.

    2002-01-01

    Fecal-indicator bacteria were sampled at 14 stream sites in Anchorage, Alaska, USA, as part of a study to determine the effects of urbanization on water quality. Population density in the subbasins sampled ranged from zero to 1,750 persons per square kilometer. Higher concentrations of fecal-coliform, E. coli, and enterococci bacteria were measured at the most urbanized sites. Although fecal-indicator bacteria concentrations were higher in summer than in winter, seasonal differences in bacteria concentrations generally were not significant. Areas served by sewer systems had significantly higher fecal-indicator bacteria concentrations than did areas served by septic systems. The areas served by sewer systems also had storm drains that discharged directly to the streams, whereas storm sewers were not present in the areas served by septic systems. Fecal-indicator bacteria concentrations were highly variable over a two-day period of stable streamflow, which may have implications for testing of compliance to water-quality standards.

  5. Assessing market-sold remedies in lomé (togo) for hygienic quality.

    PubMed

    de Souza, Comlan; Ameyapoh, Yaovi; Karou, Simplice D; Anani, Kokou T; Kpodar, Madje L; Gbeassor, Mensavi

    2011-01-01

    Traditional concoctions sold in marketplaces are always assumed to be safe and efficient; however, they can be potentially toxic because of poor hygienic practices in plant processing or storage. The present study aimed to assess for the microbial quality of market-sold vegetable drugs in Lomé. Thus, a total of 209 plant remedies were collected in marketplaces and analysed for the presence of total aerobic bacteria, total coliforms, thermotolerant coliforms, Staphylococcus aureus, sulphite reducing bacteria, and yeast and moulds according to the French Association of Normalisation (AFNOR) guidelines. The results revealed that all formulations were contaminated by several microorganisms, excepted alcohol-based mixtures. According to AFNOR limits nonconform drugs were according to total aerobic bacteria (86.96% powders, 81.82% capsules, 66.67% tisanes, and 42.11% decoctions); to total coliforms (9.10% capsules, 8.70% powders and 1.75% decoction); to yeasts and moulds (77.78% ointments, 40% calcined powders, 36.36% capsules, and 23.91% powders). The microbiological analysis revealed that the majority of contaminating bacteria were gram positive catalase positive and oxidase positive bacilli. Quality control studies on market-sold remedies are currently needed to evaluate the microbial risk in consuming these products and they may allow the standardisation of plant processing and storage.

  6. Assessing Market-Sold Remedies in Lomé (Togo) for Hygienic Quality

    PubMed Central

    de Souza, Comlan; Ameyapoh, Yaovi; Karou, Simplice D.; Anani, Kokou T.; Kpodar, Madje L.; Gbeassor, Mensavi

    2011-01-01

    Traditional concoctions sold in marketplaces are always assumed to be safe and efficient; however, they can be potentially toxic because of poor hygienic practices in plant processing or storage. The present study aimed to assess for the microbial quality of market-sold vegetable drugs in Lomé. Thus, a total of 209 plant remedies were collected in marketplaces and analysed for the presence of total aerobic bacteria, total coliforms, thermotolerant coliforms, Staphylococcus aureus, sulphite reducing bacteria, and yeast and moulds according to the French Association of Normalisation (AFNOR) guidelines. The results revealed that all formulations were contaminated by several microorganisms, excepted alcohol-based mixtures. According to AFNOR limits nonconform drugs were according to total aerobic bacteria (86.96% powders, 81.82% capsules, 66.67% tisanes, and 42.11% decoctions); to total coliforms (9.10% capsules, 8.70% powders and 1.75% decoction); to yeasts and moulds (77.78% ointments, 40% calcined powders, 36.36% capsules, and 23.91% powders). The microbiological analysis revealed that the majority of contaminating bacteria were gram positive catalase positive and oxidase positive bacilli. Quality control studies on market-sold remedies are currently needed to evaluate the microbial risk in consuming these products and they may allow the standardisation of plant processing and storage. PMID:21350662

  7. Test/QA Plan for Verification of Coliform Detection Technologies for Drinking Water

    EPA Science Inventory

    The coliform detection technologies to be tested use chromatogenic and fluorogenic growth media to detect coliforms and E. coli based on the enzymatic activity of these organisms. The systems consist of single-use sample containers that contain pre-measured reagents and can be u...

  8. Microbiological Quality of Panicum maximum Grass Silage with Addition of Lactobacillus sp. as Starter

    NASA Astrophysics Data System (ADS)

    Sumarsih, S.; Sulistiyanto, B.; Utama, C. S.

    2018-02-01

    The aim of the research was to evaluate microbiological quality of Panicum maximum grass silage with addition Lactobacillus sp as starter. The completely randomized design was been used on this research with 4 treaments and 3 replications. The treatments were P0 ( Panicum maximum grass silage without addition Lactobacillus sp ), P1 ( Panicum maximum grass silage with 2% addition Lactobacillus sp), P2 (Panicum maximum grass silage with 4% addition Lactobacillus sp) and P3 (Panicum maximum grass silage with 6% addition Lactobacillus sp).The parameters were microbial populations of Panicum maximum grass silage (total lactic acid bacteria, total bacteria, total fungi, and Coliform bacteria. The data obtained were analyzed variance (ANOVA) and further tests performed Duncan’s Multiple Areas. The population of lactic acid bacteria was higher (P<0.05) and the total bacteria, fungi and Coliform were lower (P<0.05) with addition Lactobacillus sp. Microbiological quality of Panicum maximum grass silage with addition Lactobacillus sp was better than no addition Lactobacillus sp.

  9. Next-generation sequencing identification of pathogenic bacterial genes and their relationship with fecal indicator bacteria in different water sources in the Kathmandu Valley, Nepal.

    PubMed

    Ghaju Shrestha, Rajani; Tanaka, Yasuhiro; Malla, Bikash; Bhandari, Dinesh; Tandukar, Sarmila; Inoue, Daisuke; Sei, Kazunari; Sherchand, Jeevan B; Haramoto, Eiji

    2017-12-01

    Bacteriological analysis of drinking water leads to detection of only conventional fecal indicator bacteria. This study aimed to explore and characterize bacterial diversity, to understand the extent of pathogenic bacterial contamination, and to examine the relationship between pathogenic bacteria and fecal indicator bacteria in different water sources in the Kathmandu Valley, Nepal. Sixteen water samples were collected from shallow dug wells (n=12), a deep tube well (n=1), a spring (n=1), and rivers (n=2) in September 2014 for 16S rRNA gene next-generation sequencing. A total of 525 genera were identified, of which 81 genera were classified as possible pathogenic bacteria. Acinetobacter, Arcobacter, and Clostridium were detected with a relatively higher abundance (>0.1% of total bacterial genes) in 16, 13, and 5 of the 16 samples, respectively, and the highest abundance ratio of Acinetobacter (85.14%) was obtained in the deep tube well sample. Furthermore, the bla OXA23-like genes of Acinetobacter were detected using SYBR Green-based quantitative PCR in 13 (35%) of 37 water samples, including the 16 samples that were analyzed for next-generation sequencing, with concentrations ranging 5.3-7.5logcopies/100mL. There was no sufficient correlation found between fecal indicator bacteria, such as Escherichia coli and total coliforms, and potential pathogenic bacteria, as well as the bla OXA23-like gene of Acinetobacter. These results suggest the limitation of using conventional fecal indicator bacteria in evaluating the pathogenic bacteria contamination of different water sources in the Kathmandu Valley. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Applicability of universal Bacteroidales genetic marker for microbial monitoring of drinking water sources in comparison to conventional indicators.

    PubMed

    Shahryari, A; Nikaeen, M; Khiadani Hajian, M; Nabavi, F; Hatamzadeh, M; Hassanzadeh, A

    2014-11-01

    Water quality monitoring is essential for the provision of safe drinking water. In this study, we compared a selection of fecal indicators with universal Bacteroidales genetic marker to identify fecal pollution of a variety of drinking water sources. A total of 60 samples were collected from water sources. The microbiological parameters included total coliforms, fecal coliforms, Escherichia coli and fecal streptococci as the fecal indicator bacteria (FIB), Clostridium perfringens and H2S bacteria as alternative indicators, universal Bacteroidales genetic marker as a promising alternative fecal indicator, and Salmonella spp., Shigella spp., and E. coli O157 as pathogenic bacteria. From 60 samples analyzed, Bacteroidales was the most frequently detected indicator followed by total coliforms. However, the Bacteroidales assay failed to detect the marker in nine samples positive for FIB and other alternative indicators. The results of our study showed that the absence of Bacteroidales is not necessarily an evidence of fecal and pathogenic bacteria absence and may be unable to ensure the safety of the water. Further research, however, is required for a better understanding of the use of a Bacteroidales genetic marker as an indicator in water quality monitoring programs.

  11. Escherichia coli and coliforms level of food utensils at food premises in Kuala Pilah, Malaysia

    NASA Astrophysics Data System (ADS)

    Saipullizan, Siti Nurul Ain; Mutalib, Sahilah Abd.; Sedek, Razalee

    2018-04-01

    The aim of this study was to evaluate the Escherichia coli and coliforms level of food utensils at sixty food premises in Kuala Pilah, Malaysia. The swab technique was used to investigate the presence of E. coli and coliforms on 180 of food utensils (chopping boards: 60, knives: 60 and dish plates: 60). The results indicated that 180 of food utensils were contaminated with E. coli and coliforms. More than 60% of the coliforms were exceeded the acceptable limit compared to E. coli on the food utensils. The one-way ANOVA analysis demonstrated that the presence of E. coli and coliforms differed significantly among the three types of food utensils (knives, chopping boards, and dish plates). In conclusion, this study revealed that there are hygiene issues exist in every food premises. The food utensils are safe to use during the food preparation if the presence of E. coli and coliforms are not exceed the acceptable limit. Thus, it is recommended that the food handlers in the food premises should improve effective cleaning and sanitizing of food utensils in their daily work.

  12. Removal of Escherichia coli and Faecal Coliforms from Surface Water and Groundwater by Household Water Treatment Devices/Systems: A Sustainable Solution for Improving Water Quality in Rural Communities of the Southern African Development Community Region

    PubMed Central

    Mwabi, Jocelyne K.; Mamba, Bhekie B.; Momba, Maggy N. B.

    2012-01-01

    There is significant evidence that household water treatment devices/systems (HWTS) are capable of dramatically improving microbially contaminated water quality. The purpose of this study was to examine five filters [(biosand filter-standard (BSF-S); biosand filter-zeolite (BSF-Z); bucket filter (BF); ceramic candle filter (CCF); and silver-impregnated porous pot (SIPP)] and evaluate their ability to improve the quality of drinking water at the household level. These HWTS were manufactured in the workshop of the Tshwane University of Technology and evaluated for efficiency to remove turbidity, faecal coliforms and Escherichia coli from multiple water source samples, using standard methods. The flow rates ranged from 0.05 L/h to 2.49 L/h for SIPP, 1 L/h to 4 L/h for CCF, 0.81 L/h to 6.84 L/h for BSF-S, 1.74 L/h to 19.2 L/h and 106.5 L/h to 160.5 L/h for BF The turbidity of the raw water samples ranged between 2.17 and 40.4 NTU. The average turbidity obtained after filtration ranged from 0.6 to 8 NTU (BSF-S), 1 to 4 NTU (BSF-Z), 2 to 11 NTU (BF), and from 0.6 to 7 NTU (CCF) and 0.7 to 1 NTU for SIPP. The BSF-S, BSF-Z and CCF removed 2 to 4 log10 (99% to 100%) of coliform bacteria, while the BF removed 1 to 3 log (90% to 99.9%) of these bacteria. The performance of the SIPP in removing turbidity and indicator bacteria (>5 log10, 100%) was significantly higher compared to that of the other HWTS (p < 0.05). The findings of this study indicate that the SIPP can be an effective and sustainable HWTS for the Southern African Development Community (SADC) rural communities, as it removed the total concentration of bacteria from test water, can be manufactured using locally available materials, and is easy to operate and to maintain. PMID:22470284

  13. FECAL COLIFORM INCREASE AFTER CENTRIFUGATION: EPA PERSPECTIVE

    EPA Science Inventory

    The Water Environment Research Foundation (WERF) recently published a report titled Examination of Reactivation and Regrowth of Fecal Coliforms in Anaerobically Digested Sludges. Seven full-scale publicly owned treatment facilities were sampled several times to determine if bacte...

  14. ANALYZING BIOSOLIDS FOR FECAL COLIFORM AND SALMONELLAE

    EPA Science Inventory

    Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Standard protocols designed to quantify these organisms in water or wastewater were identified and specified in these regulations. However, proto...

  15. Fecal-indicator bacteria in the Allegheny, Monongahela, and Ohio Rivers and selected tributaries, Allegheny County, Pennsylvania, 2001-2005

    USGS Publications Warehouse

    Buckwalter, Theodore F.; Zimmerman, Tammy M.; Fulton, John W.

    2006-01-01

    Concentrations of fecal-indicator bacteria were determined in 1,027 water-quality samples collected from July 2001 through August 2005 during dry- (72-hour dry antecedent period) and wet-weather (48-hour dry antecedent period and at least 0.3 inch of rain in a 24-hour period) conditions in the Allegheny, Monongahela, and Ohio Rivers (locally referred to as the Three Rivers) and selected tributaries in Allegheny County. Samples were collected at five sampling sites on the Three Rivers and at eight sites on four tributaries to the Three Rivers having combined sewer overflows. Water samples were analyzed for three fecal-indicator organisms fecal coliform, Escherichia coli (E. coli), and enterococci bacteria. Left-bank and right-bank surface-water samples were collected in addition to a cross-section composite sample at each site. Concentrations of fecal coliform, E. coli, and enterococci were detected in 98.6, 98.5, and 87.7 percent of all samples, respectively. The maximum fecal-indicator bacteria concentrations were collected from Sawmill Run, a tributary to the Ohio River; Sawmill Run at Duquesne Heights had concentrations of fecal coliform, E. coli, and enterococci of 410,000, 510,000, and 180,000 col/100 mL, respectively, following a large storm. The samples collected in the Three Rivers and selected tributaries frequently exceeded established recreational standards and criteria for bacteria. Concentrations of fecal coliform exceeded the Pennsylvania water-quality standard (200 col/100 mL) in approximately 63 percent of the samples. Sample concentrations of E. coli and enterococci exceeded the U.S. Environmental Protection Agency (USEPA) water-quality criteria (235 and 61 col/100 mL, respectively) in about 53 and 47 percent, respectively, of the samples. Fecal-indicator bacteria were most strongly correlated with streamflow, specific conductance, and turbidity. These correlations most frequently were observed in samples collected from tributary sites. Fecal

  16. Total coliforms, arsenic and cadmium exposure through drinking water in the Western Region of Ghana: application of multivariate statistical technique to groundwater quality.

    PubMed

    Affum, Andrews Obeng; Osae, Shiloh Dede; Nyarko, Benjamin Jabez Botwe; Afful, Samuel; Fianko, Joseph Richmond; Akiti, Tetteh Thomas; Adomako, Dickson; Acquaah, Samuel Osafo; Dorleku, Micheal; Antoh, Emmanuel; Barnes, Felix; Affum, Enoch Acheampong

    2015-02-01

    In recent times, surface water resource in the Western Region of Ghana has been found to be inadequate in supply and polluted by various anthropogenic activities. As a result of these problems, the demand for groundwater by the human populations in the peri-urban communities for domestic, municipal and irrigation purposes has increased without prior knowledge of its water quality. Water samples were collected from 14 public hand-dug wells during the rainy season in 2013 and investigated for total coliforms, Escherichia coli, mercury (Hg), arsenic (As), cadmium (Cd) and physicochemical parameters. Multivariate statistical analysis of the dataset and a linear stoichiometric plot of major ions were applied to group the water samples and to identify the main factors and sources of contamination. Hierarchal cluster analysis revealed four clusters from the hydrochemical variables (R-mode) and three clusters in the case of water samples (Q-mode) after z score standardization. Principal component analysis after a varimax rotation of the dataset indicated that the four factors extracted explained 93.3 % of the total variance, which highlighted salinity, toxic elements and hardness pollution as the dominant factors affecting groundwater quality. Cation exchange, mineral dissolution and silicate weathering influenced groundwater quality. The ranking order of major ions was Na(+) > Ca(2+) > K(+) > Mg(2+) and Cl(-) > SO4 (2-) > HCO3 (-). Based on piper plot and the hydrogeology of the study area, sodium chloride (86 %), sodium hydrogen carbonate and sodium carbonate (14 %) water types were identified. Although E. coli were absent in the water samples, 36 % of the wells contained total coliforms (Enterobacter species) which exceeded the WHO guidelines limit of zero colony-forming unit (CFU)/100 mL of drinking water. With the exception of Hg, the concentration of As and Cd in 79 and 43 % of the water samples exceeded the WHO guideline limits of 10 and 3

  17. Effect of Feeding Palm Oil By-Products Based Diets on Total Bacteria, Cellulolytic Bacteria and Methanogenic Archaea in the Rumen of Goats

    PubMed Central

    Abubakr, Abdelrahim; Alimon, Abdul Razak; Yaakub, Halimatun; Abdullah, Norhani; Ivan, Michael

    2014-01-01

    Rumen microorganisms are responsible for digestion and utilization of dietary feeds by host ruminants. Unconventional feed resources could be used as alternatives in tropical areas where feed resources are insufficient in terms of quality and quantity. The objective of the present experiment was to evaluate the effect of diets based on palm oil (PO), decanter cake (DC) or palm kernel cake (PKC) on rumen total bacteria, selected cellulolytic bacteria, and methanogenic archaea. Four diets: control diet (CD), decanter cake diet (DCD), palm kernel cake diet (PKCD) and CD plus 5% PO diet (CPOD) were fed to rumen cannulated goats and rumen samples were collected at the start of the experimental diets (day 0) and on days 4, 6, 8, 12, 18, 24 and 30 post dietary treatments. Feeding DCD and PKCD resulted in significantly higher (P<0.05) DNA copy number of total bacteria, Fibrobacter succinogenes, Ruminococcus flavefeciens, and Ruminococcus albus. Rumen methanogenic archaea was significantly lower (P<0.05) in goats fed PKCD and CPOD and the trend showed a severe reduction on days 4 and 6 post experimental diets. In conclusion, results indicated that feeding DCD and PKC increased the populations of cellulolytic bacteria and decreased the density of methanogenic archaea in the rumen of goats. PMID:24756125

  18. Effect of feeding palm oil by-products based diets on total bacteria, cellulolytic bacteria and methanogenic archaea in the rumen of goats.

    PubMed

    Abubakr, Abdelrahim; Alimon, Abdul Razak; Yaakub, Halimatun; Abdullah, Norhani; Ivan, Michael

    2014-01-01

    Rumen microorganisms are responsible for digestion and utilization of dietary feeds by host ruminants. Unconventional feed resources could be used as alternatives in tropical areas where feed resources are insufficient in terms of quality and quantity. The objective of the present experiment was to evaluate the effect of diets based on palm oil (PO), decanter cake (DC) or palm kernel cake (PKC) on rumen total bacteria, selected cellulolytic bacteria, and methanogenic archaea. Four diets: control diet (CD), decanter cake diet (DCD), palm kernel cake diet (PKCD) and CD plus 5% PO diet (CPOD) were fed to rumen cannulated goats and rumen samples were collected at the start of the experimental diets (day 0) and on days 4, 6, 8, 12, 18, 24 and 30 post dietary treatments. Feeding DCD and PKCD resulted in significantly higher (P<0.05) DNA copy number of total bacteria, Fibrobacter succinogenes, Ruminococcus flavefeciens, and Ruminococcus albus. Rumen methanogenic archaea was significantly lower (P<0.05) in goats fed PKCD and CPOD and the trend showed a severe reduction on days 4 and 6 post experimental diets. In conclusion, results indicated that feeding DCD and PKC increased the populations of cellulolytic bacteria and decreased the density of methanogenic archaea in the rumen of goats.

  19. Bioaugmentation Mitigates the Impact of Estrogen on Coliform-Grazing Protozoa in Slow Sand Filters.

    PubMed

    Haig, Sarah-Jane; Gauchotte-Lindsay, Caroline; Collins, Gavin; Quince, Christopher

    2016-03-15

    Exposure to endocrine-disrupting chemicals (EDCs), such as estrogens, is a growing issue for human and animal health as they have been shown to cause reproductive and developmental abnormalities in wildlife and plants and have been linked to male infertility disorders in humans. Intensive farming and weather events, such as storms, flash flooding, and landslides, contribute estrogen to waterways used to supply drinking water. This paper explores the impact of estrogen exposure on the performance of slow sand filters (SSFs) used for water treatment. The feasibility and efficacy of SSF bioaugmentation with estrogen-degrading bacteria was also investigated, to determine whether removal of natural estrogens (estrone, estradiol, and estriol) and overall SSF performance for drinking water treatment could be improved. Strains for SSF augmentation were isolated from full-scale, municipal SSFs so as to optimize survival in the laboratory-scale SSFs used. Concentrations of the natural estrogens, determined by gas chromatography coupled with mass spectrometry (GC-MS), revealed augmented SSFs reduced the overall estrogenic potency of the supplied water by 25% on average and removed significantly more estrone and estradiol than nonaugmented filters. A negative correlation was found between coliform removal and estrogen concentration in nonaugmented filters. This was due to the toxic inhibition of protozoa, indicating that high estrogen concentrations can have functional implications for SSFs (such as impairing coliform removal). Consequently, we suggest that high estrogen concentrations could impact significantly on water quality production and, in particular, on pathogen removal in biological water filters.

  20. Effects of feed-supplementation and hide-spray application of two sources of tannins on enteric and hide bacteria of feedlot cattle.

    PubMed

    Gutierrez-Banuelos, Hector; Pinchak, William E; Min, Byeng R; Carstens, Gordon E; Anderson, Robin C; Tedeschi, Luis O; Krueger, Wimberley K; Krueger, Nathan A; Lancaster, Phillip A; Gomez, Robynne R

    2011-01-01

    Pathogenic bacteria attached to the hide or shed in the feces of cattle at slaughter can contaminate carcasses intended to be processed for human consumption. Therefore, new pre-harvest interventions are needed to prevent the carriage and excretion of foodborne pathogens in cattle presented to the processing plant. The objectives of this study were to examine the antimicrobial effects of hydrolysable tannin-rich chestnut and condensed tannin-rich mimosa extracts on bacterial indicators of foodborne pathogens when applied as a hide-intervention and as a feed additive to feedlot cattle. Water (control) or solutions (3 % wt/vol) of chestnut- and mimosa-extract treatments were sprayed (25 mL) at the left costal side of each animal to a 1000 cm² area, divided in four equal quadrants. Hide-swabs samples obtained at pre-, 2-min, 8-h, and 24-h post-spray application were cultured to enumerate Escherichia coli/total coliforms and total aerobic plate counts. In a second experiment, diets supplemented without (controls) or with (1.5 % of diet dry matter) chestnut- or mimosa-extracts were fed during a 42-day experimental feeding period. Weekly fecal samples starting on day 0, and rumen fluid obtained on days 0, 7, 21 or 42 were cultured to enumerate E.coli/total coliforms and Campylobacter. Tannin spray application showed no effect of treatment or post-application-time (P > 0.05) on measured bacterial populations, averaging 1.7/1.8, 1.5/1.6 and 1.5/1.7 (log₁₀CFU/cm²) for E. coli/total coliforms, and 4.0, 3.4 and 4.2 (log₁₀CFU/cm²) in total aerobes for control, chestnut and mimosa treatments, respectively. Mean (± SEM) ruminal E. coli and total coliform concentrations (log(10) CFU/mL) were reduced (P < 0.01) in steers fed chestnut-tannins (3.6 and 3.8 ± 0.1) in comparison with the controls (4.1 and 4.2 ± 0.1). Fecal E. coli concentrations were affected by treatment (P< 0.01), showing the highest values (log₁₀ CFU/g) in fecal contents from mimosa-fed steers

  1. Volatiles emitted from eight wound-isolated bacteria differentially attract and stimulate gravid screwworm flies (Diptera: Calliphoridae) to oviposit

    USDA-ARS?s Scientific Manuscript database

    Bovine blood inoculated with bacteria isolated from screwworm-infested animal wounds was tested against gravid screwworm flies, Cochliomyia hominivorax (Coquerel) in the laboratory in a cage bioassay as an attractant for oviposition. Eight species of gram-negative coliform (Enterobacteriaceae) bacte...

  2. Influence of flooring type during transport and holding on bacteria recovery from broiler carcass rinses before and after defeathering.

    PubMed

    Buhr, R J; Cason, J A; Dickens, J A; Hinton, A; Ingram, K D

    2000-03-01

    Four trials were conducted to determine whether conventional solid or elevated wire mesh flooring, during transport and holding of broilers prior to slaughter, influenced the number of bacteria recovered from feathered and defeathered carcasses. After 4 h off feed, 7-wk-old broilers were placed at commercial density into a modified commercial transport dump-coop on either fiberglass sheeting or 2.54x2.54 cm wire mesh flooring that allowed feces to fall through. Broilers were transported for 1 h and then held for 13 h under a covered shed before processing. Broilers were killed by electrocution, and the vents were plugged to prevent escape of feces. External carcass rinses were obtained twice (from the same carcass) from eight broilers per flooring treatment per trial, before scalding and defeathering and again after defeathering and removal of the head and feet. Greater numbers of total aerobes, coliforms, and Escherichia coli were recovered from feathered carcasses than from defeathered carcasses. Campylobacter count was also less for defeathered than feathered carcasses from the solid flooring treatment but did not significantly decrease following defeathering of carcasses from the wire flooring. The incidence of Campylobacter-positive carcasses was reduced following defeathering for both flooring treatments, but the percentage of Salmonellae-positive carcasses remained constant. Coliform (log10 6.20 vs. 5.63 cfu/mL of rinse) and E. coli (log10 5.93 vs. 5.36) counts in the feathered rinses were significantly higher for the solid flooring compared with wire flooring, respectively. After defeathering, the number of coliforms (log10 3.12) and E. coli (log10 2.91) recovered did not differ between flooring treatments. Aerobic plate count (log10 7.06 and 4.02), Campylobacter count (log10 2.49 and 1.80), and the incidence of Campylobacter-positive (44 and 11%) and Salmonellae-positive (52 and 50%) carcasses for feathered and defeathered rinses, respectively, did not

  3. [Banana peel: a possible source of infection in the treatment of nipple fissures].

    PubMed

    Novak, Franz Reis; de Almeida, João Aprígio Guerra; de Souza e Silva, Rosana

    2003-01-01

    To study the microbiology of banana peel being sold in the city of Rio de Janeiro, in an attempt to determine the possibility that the peel may represent a source of infection for women who use it to treat nipple fissures. The following microorganisms were studied in 20 banana peel samples: mesophiles, total coliforms, fecal coliforms, Pseudomonas aeruginosa, lipolytic and proteolytic microorganisms, molds and yeasts, lactic bacteria, and coagulase-positive staphylococcus. The microbiological analyses revealed the occurrence of several typical groups of microorganisms, with the following distribution of positive results being detected in banana peel samples: mesophiles, 100%; total coliforms, 20%; coagulase-positive staphylococcus, 25%; molds and yeasts, 30%; proteolytic microorganisms, 70%; lipolytic microorganisms, 30%, and lactic bacteria, 95%. Fecal coliforms and Pseudomonas aeruginosa were not isolated. The results show the presence of potentially pathogenic microorganisms in levels which could compromise the microbiological quality of the banana peel. Its use for the treatment of nipple fissures can initiate an infectious process.

  4. Microorganisms in stormwater; a summary of recent investigations

    USGS Publications Warehouse

    Mallard, Gail E.

    1980-01-01

    All storm runoff contains a variety of bacteria, including total coliform, fecal coliform, and fecal streptococci, which are derived from the land over which the water flows. Most total coliform are native soil organisms, whereas the fecal coliform and fecal streptococci originate from the feces of wild and domestic animals. Urban runoff has been reported to contain pathogenic organisms, but this probably presents little direct threat to human health because the runoff is not ingested. Runoff water can, however, have other negative effects such as contamination of surface water, which may result in beach closures, or contamination of shellfish. This type of contamination is generally of short duration because indicator bacteria and pathogens die out rapidly in the aquatic environment. Similarly, bacteria and viruses deposited on soil by stormwater are inactivated by drying, competition from soil microflora, and a variety of other processes. Every storm producing runoff is unique in the number and type of microorganisms because these vary from site to site, from storm to storm, and during the course of the storm. Stormwater to be examined for microorganisms must be collected in sterile containers and processed immediately. (USGS)

  5. Microbiological quality and safety of cooking butter in Beni-Suef governorate-Egypt.

    PubMed

    Meshref, A M S

    2010-06-01

    Cooking butter is one of the most popular types of fat consumed in Egyptian houses. It is produced in villages by rural women that are usually using their traditional knowledge during manufacturing. To study the rate of contamination and hygienic quality of cooking butter A total of 60 random samples of cooking butter, were collected from different farmers' houses in different villages, Beni-Suef Governorate, Egypt. Cooking butter samples were examined for psychrotrophic bacteria, total coliforms, faecal coliforms and molds and yeasts counts. Additionally examination for the presence of pathogenic bacteria like E.coli, S.aureus and Ps.aeruginosa were also performed. The microbiological examination revealed that 100, 100, 36.7, 31.7, 31.7 and 23.3% of the examined samples were contaminated by psychrotrophic bacteria, molds and yeasts, coliforms, faecal coliforms, E.coli and S.aureus, respectively. None of the examined cooking butter samples contained Ps.aeruginosa. The means values of sodium chloride and titratable acidity were 0.57 ± 0.05 % and 0.20 ± 0.013%, respectively. The present study showed that cooking butter is produced under unhygienic condition and without good manufacturing practice. The Public health significance and suggestive control measures are discussed.

  6. Distribution and sources of surfzone bacteria at Huntington Beach before and after disinfection on an ocean outfall - A frequency-domain analysis

    USGS Publications Warehouse

    Noble, M.A.; Xu, J. P.; Robertson, G.L.; Rosenfeld, L.K.

    2006-01-01

    Fecal indicator bacteria (FIB) were measured approximately 5 days a week in ankle-depth water at 19 surfzone stations along Huntington Beach and Newport Beach, California, from 1998 to the end of 2003. These sampling periods span the time before and after treated sewage effluent, discharged into the coastal ocean from the local outfall, was disinfected. Bacterial samples were also taken in the vicinity of the outfall during the pre- and post-disinfection periods. Our analysis of the results from both data sets suggest that land-based sources, rather than the local outfall, were the source of the FIB responsible for the frequent closures and postings of local beaches in the summers of 2001 and 2002. Because the annual cycle is the dominant frequency in the fecal and total coliform data sets at most sampling stations, we infer that sources associated with local runoff were responsible for the majority of coliform contamination along wide stretches of the beach. The dominant fortnightly cycle in enterococci at many surfzone sampling stations suggests that the source for these relatively frequent bacteria contamination events in summer is related to the wetting and draining of the land due to the large tidal excursions found during spring tides. Along the most frequently closed section of the beach at stations 3N-15N, the fortnightly cycle is dominant in all FIBs. The strikingly different spatial and spectral patterns found in coliform and in enterococci suggest the presence of different sources, at least for large sections of beach. The presence of a relatively large enterococci fortnightly cycle along the beaches near Newport Harbor indicates that contamination sources similar to those found off Huntington Beach are present, though not at high enough levels to close the Newport beaches. ?? 2006 Elsevier Ltd. All rights reserved.

  7. Distribution and sources of surfzone bacteria at Huntington Beach before and after disinfection on an ocean outfall-- a frequency-domain analysis.

    PubMed

    Noble, M A; Xu, J P; Robertson, G L; Rosenfeld, L K

    2006-06-01

    Fecal indicator bacteria (FIB) were measured approximately 5 days a week in ankle-depth water at 19 surfzone stations along Huntington Beach and Newport Beach, California, from 1998 to the end of 2003. These sampling periods span the time before and after treated sewage effluent, discharged into the coastal ocean from the local outfall, was disinfected. Bacterial samples were also taken in the vicinity of the outfall during the pre- and post-disinfection periods. Our analysis of the results from both data sets suggest that land-based sources, rather than the local outfall, were the source of the FIB responsible for the frequent closures and postings of local beaches in the summers of 2001 and 2002. Because the annual cycle is the dominant frequency in the fecal and total coliform data sets at most sampling stations, we infer that sources associated with local runoff were responsible for the majority of coliform contamination along wide stretches of the beach. The dominant fortnightly cycle in enterococci at many surfzone sampling stations suggests that the source for these relatively frequent bacteria contamination events in summer is related to the wetting and draining of the land due to the large tidal excursions found during spring tides. Along the most frequently closed section of the beach at stations 3N-15N, the fortnightly cycle is dominant in all FIBs. The strikingly different spatial and spectral patterns found in coliform and in enterococci suggest the presence of different sources, at least for large sections of beach. The presence of a relatively large enterococci fortnightly cycle along the beaches near Newport Harbor indicates that contamination sources similar to those found off Huntington Beach are present, though not at high enough levels to close the Newport beaches.

  8. Assessing the sources of high fecal coliform levels at an urban tropical beach

    PubMed Central

    Davino, Aline Mendonça Cavalcante; de Melo, Milena Bandeira; Caffaro, Roberto Augusto

    2015-01-01

    Recreational water quality is commonly assessed by microbial indicators such as fecal coliforms. Maceió is the capital of Alagoas state, located in tropical northeastern Brazil. Its beaches are considered as the most beautiful urban beaches in the country. Jatiúca Beach in Maceió was found to be unsuitable for bathing continuously during the year of 2011. The same level of contamination was not observed in surrounding beaches. The aim of this study was to initiate the search for the sources of these high coliform levels, so that contamination can be eventually mitigated. We performed a retrospective analysis of historical results of fecal coliform concentrations from 2006 to 2012 at five monitoring stations located in the study region. Results showed that Jatiúca Beach consistently presented the worst quality among the studied beaches. A field survey was conducted to identify existing point and non-point sources of pollution in the area. Monitoring in the vicinity of Jatiúca was spatially intensified. Fecal coliform concentrations were categorized according to tide range and tide stage. A storm drain located in northern Jatiúca was identified as the main point source of the contamination. However, fecal coliform concentrations at Jatiúca were high during high tides and spring tides even when this point source was inactive (no rainfall). We hypothesize that high fecal coliform levels in Jatiúca Beach may also be caused by aquifer contamination or, more likely, from tide washing of contaminated sand. Both of these hypotheses will be further investigated. PMID:26691459

  9. Assessing the sources of high fecal coliform levels at an urban tropical beach.

    PubMed

    Davino, Aline Mendonça Cavalcante; de Melo, Milena Bandeira; Caffaro Filho, Roberto Augusto

    2015-01-01

    Recreational water quality is commonly assessed by microbial indicators such as fecal coliforms. Maceió is the capital of Alagoas state, located in tropical northeastern Brazil. Its beaches are considered as the most beautiful urban beaches in the country. Jatiúca Beach in Maceió was found to be unsuitable for bathing continuously during the year of 2011. The same level of contamination was not observed in surrounding beaches. The aim of this study was to initiate the search for the sources of these high coliform levels, so that contamination can be eventually mitigated. We performed a retrospective analysis of historical results of fecal coliform concentrations from 2006 to 2012 at five monitoring stations located in the study region. Results showed that Jatiúca Beach consistently presented the worst quality among the studied beaches. A field survey was conducted to identify existing point and non-point sources of pollution in the area. Monitoring in the vicinity of Jatiúca was spatially intensified. Fecal coliform concentrations were categorized according to tide range and tide stage. A storm drain located in northern Jatiúca was identified as the main point source of the contamination. However, fecal coliform concentrations at Jatiúca were high during high tides and spring tides even when this point source was inactive (no rainfall). We hypothesize that high fecal coliform levels in Jatiúca Beach may also be caused by aquifer contamination or, more likely, from tide washing of contaminated sand. Both of these hypotheses will be further investigated.

  10. [Spring water quality assessment regarding the problem of endemic fluorosis].

    PubMed

    Leshchenko, D V; Mialo, O A; Beliakova, M B; Beliaeva, E A; Samoukina, A M; Chervinets, Iu V; Ivanova, O V

    2013-01-01

    A possible variant for reducing the consumption of fluoride by population of Tver region is the use of water with low fluoride content, such as spring water. Assessment of drinking suitability of spring water (the content of physiologically important mineral elements and microbial purity) is relevant to our region. Water samples from 6 spring-water source of Tver region were studied during the year. The content of fluoride and calcium were measured by using an ion-selective electrodes. Microbiological purity tested by the presence of total coliform bacteria, thermotolerant coliform bacteria, coliphages and total microbial numbers. The analysis of some mineral components in spring water of Tver region showed that calcium content was in range 33-88 mg/l, that satisfied the recommended value; fluoride concentration is less then 0.5 mg/l. In all spring water samples total coliforms, thermotolerant coliforms and coliphages were absent. The total microbial number was in standard range, except of two spring-water source in the autumn and summer. The data suppose that spring water of Tver region can be used as a component of diet normalizing the fluoride consumption at risk of dental fluorosis in children.

  11. Inactivation of particle-associated coliforms by chlorine and monochloramine.

    PubMed Central

    Berman, D; Rice, E W; Hoff, J C

    1988-01-01

    Sieves and nylon screens were used to separate primary sewage effluent solids into particle fractions of less than 7- or greater than 7-micron size. The efficiency of separation was determined by using a particle counter. Indigenous coliforms associated with the particle fractions were tested for their resistance to chlorine and monochloramine. Coliforms associated with the less than 7-microns fraction were inactivated more rapidly by 0.5 mg of chlorine per liter at 5 degrees C and pH 7 than coliforms associated with the greater than 7-microns fraction. Homogenization of the greater than 7-microns fraction not only resulted in an increase in the number of less than 7-microns particles, but also increased the rate of inactivation to a rate similar to that of the less than 7-microns fraction. With 1 mg of monochloramine per liter at 5 degrees C and pH 7, particle size had no appreciable effect on the rate of inactivation. At pH 8, however, the less than 7-micron fraction was inactivated more rapidly than the greater than 7-micron fraction. The time required for 99% inactivation of the particle fractions with monochloramine at pH 7 or 8 was 20- to 50-fold greater than the time required for the same amount of inactivation with chlorine at pH 7. The results indicate that coliforms associated with sewage effluent particles are inactivated more rapidly with 0.5 mg of chlorine per liter than with 1.0 mg of monochloramine per liter. However, greater than 7-micron particles can have a protective effect against the disinfecting action of chlorine. PMID:3355136

  12. Comparison of fecal indicators with pathogenic bacteria and rotavirus in groundwater

    PubMed Central

    Ferguson, Andrew S.; Layton, Alice C.; Mailloux, Brian J; Culligan, Patricia J.; Williams, Daniel E.; Smartt, Abby E.; Sayler, Gary S.; Feighery, John; McKay, Larry; Knappett, Peter S.K.; Alexandrova, Ekaterina; Arbit, Talia; Emch, Michael; Escamilla, Veronica; Ahmed, Kazi Matin; Alam, Md. Jahangir; Streatfield, P. Kim; Yunus, Mohammad; van Geen, Alexander

    2012-01-01

    Groundwater is routinely analyzed for fecal indicators but direct comparisons of fecal indicators to the presence of bacterial and viral pathogens are rare. This study was conducted in rural Bangladesh where the human population density is high, sanitation is poor, and groundwater pumped from shallow tubewells is often contaminated with fecal bacteria. Five indicator microorganisms (E. coli, total coliform, F+RNA coliphage, Bacteroides and human-associated Bacteroides) and various environmental parameters were compared to the direct detection of waterborne pathogens by quantitative PCR in groundwater pumped from 50 tubewells. Rotavirus was detected in groundwater filtrate from the largest proportion of tubewells (40%), followed by Shigella (10%), Vibrio (10%), and pathogenic E. coli (8%). Spearman rank correlations and sensitivity-specificity calculations indicate that some, but not all, combinations of indicators and environmental parameters can predict the presence of pathogens. Culture-dependent fecal indicator bacteria measured on a single date did not predict total bacterial pathogens, but annually averaged monthly measurements of culturable E. coli did improve prediction for total bacterial pathogens. A qPCR-based E. coli assay was the best indicator for the bacterial pathogens. F+RNA coliphage were neither correlated nor sufficiently sensitive towards rotavirus, but were predictive of bacterial pathogens. Since groundwater cannot be excluded as a significant source of diarrheal disease in Bangladesh and neighboring countries with similar characteristics, the need to develop more effective methods for screening tubewells with respect to microbial contamination is necessary. PMID:22705866

  13. Sampling and Pooling Methods for Capturing Herd Level Antibiotic Resistance in Swine Feces using qPCR and CFU Approaches

    PubMed Central

    Mellerup, Anders; Ståhl, Marie

    2015-01-01

    The aim of this article was to define the sampling level and method combination that captures antibiotic resistance at pig herd level utilizing qPCR antibiotic resistance gene quantification and culture-based quantification of antibiotic resistant coliform indicator bacteria. Fourteen qPCR assays for commonly detected antibiotic resistance genes were developed, and used to quantify antibiotic resistance genes in total DNA from swine fecal samples that were obtained using different sampling and pooling methods. In parallel, the number of antibiotic resistant coliform indicator bacteria was determined in the same swine fecal samples. The results showed that the qPCR assays were capable of detecting differences in antibiotic resistance levels in individual animals that the coliform bacteria colony forming units (CFU) could not. Also, the qPCR assays more accurately quantified antibiotic resistance genes when comparing individual sampling and pooling methods. qPCR on pooled samples was found to be a good representative for the general resistance level in a pig herd compared to the coliform CFU counts. It had significantly reduced relative standard deviations compared to coliform CFU counts in the same samples, and therefore differences in antibiotic resistance levels between samples were more readily detected. To our knowledge, this is the first study to describe sampling and pooling methods for qPCR quantification of antibiotic resistance genes in total DNA extracted from swine feces. PMID:26114765

  14. Characterization and application of lactic acid bacteria for tropical silage preparation.

    PubMed

    Pholsen, Suradej; Khota, Waroon; Pang, Huili; Higgs, David; Cai, Yimin

    2016-10-01

    Strains TH 14, TH 21 and TH 64 were isolated from tropical silages, namely corn stover, sugar cane top and rice straw, respectively, prepared in Thailand. These strains were selected by low pH growth range and high lactic acid-producing ability, similar to some commercial inoculants. Based on the analysis of 16S ribosomal RNA gene sequence and DNA-DNA relatedness, strain TH 14 was identified as Lactobacillus casei, and strains TH 21 and TH 64 were identified as L. plantarum. Strains TH 14, TH 21, TH 64 and two commercial inoculants, CH (L. plantarum) and SN (L. rhamnosus), were used as additives to fresh and wilted purple Guinea and sorghum silages prepared using a small-scale fermentation method. The number of epiphytic lactic acid bacteria (LAB) in the forages before ensilage was relatively low but the numbers of coliform and aerobic bacteria were higher. Sorghum silages at 30 days of fermentation were all well preserved with low pH (3.56) and high lactic acid production (72.86 g/kg dry matter). Purple Guinea silage inoculated with LAB exhibited reduced count levels of aerobic and coliform bacteria, lower pH, butyric acid and ammonia nitrogen and increased lactic acid concentration, compared with the control. Strain TH 14 more effectively improved lactic acid production compared with inoculants and other strains. © 2016 Japanese Society of Animal Science. © 2016 Japanese Society of Animal Science.

  15. Occurrence and distribution of fecal indicator bacteria and gene markers of pathogenic bacteria in Great Lakes tributaries, March-October 2011

    USGS Publications Warehouse

    Brennan, Angela K.; Johnson, Heather E.; Totten, Alexander R.; Duris, Joseph W.

    2015-01-01

    Water samples were analyzed for the presence of FIB concentrations (FIB; fecal coliform bacteria, Escherichia coli [E. coli], and enterococci) by using membrane filtration and serial dilution methods. The resulting enrichments from standard culturing of the samples were then analyzed by using polymerase chain reaction (PCR) to determine the occurrence of pathogen gene markers for Shigella species, Campylobacter jejuni and coli, Salmonellaspecies, and pathogenic E. coli, including Shiga toxin-producing E. coli (STEC).

  16. Influence of Ileo-Caecal Cannulation and Oxytetracycline on Ileo-Caecal and Rectal Coliform Populations in Pigs

    PubMed Central

    Högberg, A; Lindberg, JE; Wallgren, P

    2001-01-01

    The effect of surgery (insertion of an ileo-caecal cannula) and a subsequent parenteral treatment with oxytetracycline on the ileo-caecal and rectal coliform populations in 7 Swedish Yorkshire castrates were studied. Samples were collected during surgery as well as 3, 7, 14 and 20 days post surgery. The diversity of the enteric coliform flora was initially high both in the ileo-caecal ostium and in rectum. No alteration in the diversity of the enteric coliform flora was observed following surgery and treatment with oxytetracycline. As the insertion of ileo-caecal cannulas did not affect the intestinal coliform flora this study gives support to the use of this technique to mirror processes in the small intestine of pigs. Further, the diversity of the enteric coliform flora was unaffected by the parenteral treatment with oxytetracycline. PMID:11957371

  17. Incidence of antibiotic resistance in coliforms from drinking water and their identification using the Biolog and the API identification systems.

    PubMed

    Tokajian, S; Hashwa, F

    2004-02-01

    Antibiotic-resistant bacteria were common in samples collected from an intermittent water distribution system in Lebanon. Multiply-resistant isolates were also present and most commonly to amoxycillin, cephalexin and sulfamethoxazole/trimethoprim. The aminoglycosides (amikacin, gentamicin and kanamycin) were the most effective, with almost all tested strains showing susceptibility to these antimicrobial agents. Both the Biolog GN MicroPlates and the API 20E strips can be used for the identification of coliform bacteria isolated from potable water, but the outcome of the identification should be viewed with caution. 51% of isolates were assigned similar identities by both the Biolog MicroPlates and the API 20E strips. The similarity at the species level was lower (33%) compared to that at the genus level (67%). The identification of Escherichia coli strains, which represented 30% of all tested organisms, showed 95% similarity in the assigned genus and species using both identification schemes.

  18. Assessment of Fecal Indicator Bacteria and Potential Pathogen Co-Occurrence at a Shellfish Growing Area

    PubMed Central

    Leight, Andrew K.; Crump, Byron C.; Hood, Raleigh R.

    2018-01-01

    Routine monitoring of shellfish growing waters for bacteria indicative of human sewage pollution reveals little about the bacterial communities that co-occur with these indicators. This study investigated the bacterial community, potential pathogens, and fecal indicator bacteria in 40 water samples from a shellfish growing area in the Chesapeake Bay, USA. Bacterial community composition was quantified with deep sequencing of 16S rRNA gene amplicons, and absolute gene abundances were estimated with an internal standard (Thermus thermophilus genomes). Fecal coliforms were quantified by culture, and Vibrio vulnificus and V. parahaemolyticus with quantitative PCR. Fecal coliforms and V. vulnificus were detected in most samples, and a diverse assemblage of potential human pathogens were detected in all samples. These taxa followed two general patterns of abundance. Fecal coliforms and 16S rRNA genes for Enterobacteriaceae, Aeromonas, Arcobacter, Staphylococcus, and Bacteroides increased in abundance after a 1.3-inch rain event in May, and, for some taxa, after smaller rain events later in the season, suggesting that these are allochthonous organisms washed in from land. Clostridiaceae and Mycobacterium 16S rRNA gene abundances increased with day of the year and were not positively related to rainfall, suggesting that these are autochthonous organisms. Other groups followed both patterns, such as Legionella. Fecal coliform abundance did not correlate with most other taxa, but were extremely high following the large rainstorm in May when they co-occurred with a broad range of potential pathogen groups. V. vulnificus were absent during the large rainstorm, and did not correlate with 16S rRNA abundances of Vibrio spp. or most other taxa. These results highlight the complex nature of bacterial communities and the limited utility of using specific bacterial groups as indicators of pathogen presence. PMID:29593669

  19. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations required monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then...

  20. STANDARDIZATION AND VALIDATION OF METHODS FOR ENUMERATION OF FECAL COLIFORM AND SALMONELLA IN BIOSOLIDS

    EPA Science Inventory

    Current federal regulations require monitoring for fecal coliforms or Salmonella in biosolids destined for land application. Methods used for analysis of fecal coliforms and Salmonella were reviewed and a standard protocol was developed. The protocols were then evaluated by testi...

  1. Water-quality investigations of the Jordan River, Salt Lake County, Utah, 1980-82

    USGS Publications Warehouse

    Stephens, D.W.

    1984-01-01

    Water-quality studies were conducted on the Jordan River, Utah, to investigate specific problems: dissolved oxygen, toxic substances, sanitary quality, and turbidity and suspended sediment. The dissolved oxygen decreased from 8 milligrams per liter at the Jordan Narrows to less than 5 milligrams per liter at 500 North Street. Chemical oxygen demand increased about 23 percent and biochemical oxygen demand increased 90 percent. Nearly 78 percent of the water samples analyzed for total mercury exceeded the State intended-use standard of 0.05 microgram per liter. Concentrations of ammonia, cadmium, copper, lead, and zinc exceeded the standards periodically. The pesticides DDD, DDE, DDT, dieldrin, methoxychlor, and 2,4-D were occasionally detected in bottom materials. Most were present in quantities of less than 15 micrograms per kilogram. Concentrations of three indicator bacteria (total coliform, fecal coliform, and fecal streptococcus) increased in a downstream direction. Concentrations of total coliform bacteria often exceeded 5,000 colonies per 100 milliliters and concentrations of fecal coliform bacteria often exceeded 2,000 colonies per 100 milliliters. The primary sources of turbidity in the Jordan River are Utah Lake and discharges from the wastewater-treatment plants. Large values of turbidity were measured at the Jordan Narrows with a summer mean value of 88 nephelometer turbidity units (NTU) and a winter mean value of 43 NTU. (USGS)

  2. Assessment of the quality of water from hand-dug wells in ghana.

    PubMed

    Nkansah, Marian Asantewah; Boadi, Nathaniel Owusu; Badu, Mercy

    2010-04-26

    This study focused upon the determination of physicochemical and microbial properties, including metals, selected anions and coliform bacteria in drinking water samples from hand-dug wells in the Kumasi metropolis of the Republic of Ghana. The purpose was to assess the quality of water from these sources. Ten different water samples were taken from different parts of Kumasi, the capital of the Ashanti region of Ghana and analyzed for physicochemical parameters including pH, electrical conductivity, total dissolved solids, alkalinity total hardness and coliform bacteria. Metals and anions analyzed were Ca, Mg, Fe, Mn, NO(3) (-), NO(2) (-), SO(4) (2-), PO(4) (2-), F(-) and Cl(-). Bacteria analysed were total coliform and Escherichia coli.THE DATA SHOWED VARIATION OF THE INVESTIGATED PARAMETERS IN SAMPLES AS FOLLOWS: pH, 6.30-0.70; conductivity (EC), 46-682 muS/cm; PO(4) (3-), 0.67-76.00 mg/L; F(-), 0.20-0.80 mg/L; NO(3) (-), 0-0.968 mg/L; NO(2) (-), 0-0.063 mg/L; SO(4) (2-), 3.0-07.0 mg/L; Fe, 0-1.2 mg/L; Mn, 0-0.018 mg/L. Total coliform and Escherichia coli were below the minimum detection limit (MDL) of 20 MPN per 100 ml in all the samples. The concentrations of most of the investigated parameters in the drinking water samples from Ashanti region were within the permissible limits of the World Health Organization drinking water quality guidelines.

  3. Presence of faecal indicator bacteria in groundwaters in Kathmandu Valley, Nepal

    NASA Astrophysics Data System (ADS)

    Nishida, K.; Shrestha, S.; Tanaka, Y.; Haramoto, E.; Nakamura, T.; Osaka, K.; Chapagain, S.

    2010-12-01

    Groundwater quality is a critical problem in Kathmandu Valley, Nepal. The population of the city increased 6 times in the last six decades and more than half of water demand depends on groundwater resource. Nevertheless, few data of microorganism presence have been reported qualitatively in the central area of the valley. We investigated distribution of faecal indicator bacteria (Total coliforms and Escherichia coli) detected in wells and analyzed the variations of the concentrations. Groundwater samples were collected from 12 deep tube wells (170-300m depths) and 36 shallow tube wells and dug wells (3-20m depths) in Aug 2008, Jan 2009, Aug 2009 and Aug 2010. River waters were also collected for analyzing effect on groundwater quality. E. coli was detected from most of all wells; the concentrations were within 1 log cfu/100mL in deep tube wells and shallow tube wells while those in dug wells ranged from 1 to 3 log cfu/100mL. E. coli was detected at extremely high level in river water, from 5 to 7 log cfu/100mL, however, no clear relation was observed between E. coli concentrations in any types of groundwaters and distance of wells from adjacent rivers. These results indicate that both types of tube wells were rather protected and dug wells were most vulnerable for faecal contamination at very local scale. Genetic analysis of bacterial communities for deep well samples showed the existence of Enterobacter, Acinetobacter as well as Methane-metabolizing groups which provide information of possible indicators other than total coliforms or E. coli for groundwater management in the valley.

  4. Reconnaissance of water-quality characteristics of streams in the City of Charlotte and Mecklenburg County, North Carolina

    USGS Publications Warehouse

    Eddins, W.H.; Crawford, J.K.

    1984-01-01

    In 1979-81, water samples were collected from 119 sites on streams throughout the City of Charlotte and Mecklenburg County, North Carolina, and were analyzed for specific conductance, dissolved chloride, hardness, pH, total alkalinity, total phosphorus, trace elements, arsenic, cadmium, chromium, copper, iron, lead, manganese, mercury, silver, and zinc and biological measures including dissolved oxygen, biochemical oxygen demand, fecal coliform bacteria, and fecal streptococcus bacteria. Sampling was conducted during both low flow (base flow) and high flow. Several water-quality measures including pH, total arsenic, total cadmium, total chromium, total copper, total iron, total lead, total manganese, total mercury, total silver, total zinc, dissolved oxygen, and fecal coliform bacteria at times exceeded North Carolina water-quality standards in various streams. Runoff from non-point sources appears to contribute more to the deterioration of streams in Charlotte and Mecklenburg County than point-source effluents. Urban and industrial areas contribute various trace elements. Residential and rural areas and municipal waste-water treatment plants contribute high amounts of phosphorus.

  5. A comparison between minerals-modified glutamate medium and lauryl tryptose lactose broth for the enumeration of Escherichia coli and coliform organisms in water by the multiple tube method.

    PubMed Central

    1980-01-01

    In a multi-laboratory trial, minerals-modified glutamate medium (MMGM) was compared with lauryl tryptose lactose broth (LTLB) in the multiple tube method for the enumeration of coliform organisms, including Escherichia coli, in water. Samples of raw and chlorinated waters yielded a total of 2313 positive tube-reactions with MMGM and 2174 with LTLB. These were interpreted either as E. coli; other coliform organisms; or as false positive reactions. The results at first reading (18 or 24 h) and at 48 h have been analysed statistically in terms of (i) most probable numbers of coliform organisms; (ii) positive reactions and their interpretation; and (iii) whether or not the sample yielded any E. coli or other coliform organisms. All three analyses indicated the same trends. For the detection of E. coli in raw waters LTLB was better than MMGM at 18-24 h, but MMGM was better at 48 h with waters containing small numbers of coliform organisms; for raw waters with greater numbers of organisms, both media performed equally well. Analysis of a subset of samples read at both 18 and 24 h indicated that the superiority of LTLB over MMGM with raw waters disappeared by 24 h. For chlorinated waters, LTLB yielded more positive gas reactions at 18-24 h, but fewer of these were E. coli than with MMGM; at 48 h MMGM was clearly better than LTLB for total coliform organisms including E. coli--especially if the numbers were small. MMGM therefore remains the medium of choice for the detection of E. coli as an indicator of faecal contamination of chlorinated drinking water supplies. It is also better for the detection of small numbers of E. coli in other waters. PMID:6762395

  6. Prevalence of coliforms, Salmonella, Listeria, and Campylobacter associated with eggs and the environment of conventional cage and free-range egg production.

    PubMed

    Jones, D R; Anderson, K E; Guard, J Y

    2012-05-01

    There is a desire by US consumers for eggs produced by hens in alternative production systems. As the retail shell-egg market offers these products to accommodate consumer demands, additional information is needed to ensure processing methodologies result in safe eggs from all egg sources. A study was conducted to determine if there were differences in the prevalence of coliforms, Salmonella, Listeria, and Campylobacter on and within eggs and in the environment of a sister flock of conventional cage and free-range laying hens. Microbial sampling occurred approximately every 6 wk between 20 and 79 wk of age. A random sampling of typical coliform colonies produced 371 viable isolates for biochemical identification. Twenty-nine genera or species of bacteria were identified. There was a significantly greater (P < 0.0001) prevalence of Campylobacter in the free-range nest box swabs compared with that in the free-range grass and conventional cage swab samples (number of positives: 8 nest box, 1 grass, 0 cage). Seven isolates of Listeria innocua were detected with no significant difference in prevalence between the treatments. Isolates were associated with eggshells (2 free-range floor, 1 cage) and the free-range environment (2 nest box, 2 grass). There were 21 Salmonella isolates detected between all sample locations, with no significant difference in the prevalence of Salmonella detection between the treatments. Additional studies are needed to fully understand the effect of alternative production methods on the prevalence of pathogens and coliforms associated with nest-run eggs and the production environment.

  7. Efficiency of autothermal thermophilic aerobic digestion and thermophilic anaerobic digestion of municipal wastewater sludge in removing Salmonella spp. and indicator bacteria.

    PubMed

    Zábranská, J; Dohányos, M; Jenícek, P; Růziciková, H; Vránová, A

    2003-01-01

    The study is focused on the comparison of autothermal thermophilic aerobic digestion, thermophilic and mesophilic anaerobic digestion, based on long-term monitoring of all processes in full-scale wastewater treatment plants, with an emphasis on the efficiency in destroying pathogens. The hygienisation effect was evaluated as a removal of counts of indicator bacteria, thermotolerant coliforms and enterococci as CFU/g total sludge solids and a frequency of a positive Salmonella spp. detection. Both thermophilic technologies of municipal wastewater sludge stabilisation had the capability of producing sludge A biosolids suitable for agricultural land application when all operational parameters (mainly temperature, mixing and retention time) were stable and maintained at an appropriate level.

  8. Linking on-farm dairy management practices to storm-flow fecal coliform loading for California coastal watersheds.

    PubMed

    Lewis, D J; Atwill, E R; Lennox, M S; Hou, L; Karle, B; Tate, K W

    2005-08-01

    How and where to improve water quality within an agricultural watershed requires data at a spatial scale that corresponds with individual management decision units on an agricultural operation. This is particularly true in the context of water quality regulations, such as Total Maximum Daily Loads (TMDLs), that identify agriculture as one source of non-point source pollution through larger tributary watershed scale and above and below water quality investigations. We have conducted a systems approach study of 10 coastal dairies and ranches to document fecal coliform concentration and loading to surface waters at the management decision unit scale. Water quality samples were collected on a storm event basis from loading units that included: manure management systems; gutters; storm drains; pastures; and corrals and lots. In addition, in-stream samples were collected above and below the dairy facilities and from a control watershed, managed for light grazing and without a dairy facility or human residence and corresponding septic system. Samples were analyzed for fecal coliform concentration by membrane filtration. Instantaneous discharge was measured for each collected sample. Storm runoff was also calculated using the curve number method (SCS, 1985). Results for a representative dairy as well as the entire 10 dairy data set are presented. Fecal coliform concentrations demonstrate high variability both within and between loading units. Fecal coliform concentrations for pastures range from 206 to 2,288,888 cfu/100 ml and for lots from 1,933 to 166,105,000 cfu/100 ml. Mean concentrations for pastures and lots are 121,298 (SE = 62,222) and 3,155,584 (SE = 1,902,713) cfu/100 ml, respectively. Fecal coliform load from units of concentrated animals and manure are significantly more than units such as pastures while storm flow amounts were significantly less. Compared with results from earlier tributary scale studies in the watershed, this systems approach has generated

  9. Phenotypic analysis of antibiotic resistant E. coli recovered from urban aquatic environment in Banda Aceh, Indonesia

    NASA Astrophysics Data System (ADS)

    Suhartono, S.; Ismail, Y. S.; Yulvizar, C.; Nursanty, R.; Mahyuddin, M.; Jannah, M.

    2018-03-01

    Of aquatic environment, antibiotic resistant bacteria, including total coliforms and E. coli disseminate and emerge at an alarming rate. The study aims to determine enumerate, isolate,E. coliand determine their antibiotic resistance and compare between those which were recovered from residentials and home industries in Banda Aceh and its surrounding area. The bacterial density and antibiotic susceptibility of total coliforms and E. coli were determined using Standard Total Coliform Multiple-Tube (MPN) Fermentation method and the disk diffusion method, respectively. Despite there was no significant difference of total coliforms and E. coli population between residentials and home industries (P > 0.05) in this study, their density as well as prevalence remained high in the water sample. This might expose serious health risks since the resistance might be easily spread acquired through horizontal gene transfer within the aquatic environment.

  10. The microbiological quality of drinking water sold on the streets in Kumasi, Ghana.

    PubMed

    Obiri-Danso, K; Okore-Hanson, A; Jones, K

    2003-01-01

    The aim of this study was to assess the microbiological quality of Ghanaian bottled and plastic-bagged drinking water sold on the streets of Metropolitan Kumasi, Ghana. Eight bottled, 88 factory-filled plastic sachet and 40 hand-filled hand-tied polythene-bagged drinking waters were examined for the presence of heterotrophic bacteria total viable counts (TVCs), indicators of faecal contamination (total coliforms, faecal coliforms and enterococci) and for lead, manganese and iron. Heterotrophic bacteria were found in all three types of water with TVCs per millilitre ranging from 1 to 460 for bottled water, 2-6.33 x 10(5) for factory-bagged sachet water and 2.33 x 10(3)-7.33 x 10(12) for hand-filled hand-tied bagged water. None of the microbial indicators of faecal contamination were detected in bottled water, whereas 4.5% of the factory-bagged sachets contained total coliforms and 2.3% faecal coliforms, and 42.5% of the hand-filled hand-tied bags contained total coliforms, 22.5% faecal coliforms and 5% enterococci. Iron was found in all three types of drinking water but at concentrations well within the WHO recommendations. Lead and manganese were not detected. Ghanaian bottled water is of good microbiological quality but some factory-bagged sachet and hand-filled hand-tied polythene-bagged drinking water are of doubtful quality. Factory-bagged sachets and hand-filled hand-tied bags of drinking water sold in Ghana should be monitored for microbiological contamination, with the aim of raising standards in the industry and re-assuring the public.

  11. Polyunsaturated fatty acids influence differential biosynthesis of oxylipids and other lipid mediators during bovine coliform mastitis.

    PubMed

    Mavangira, Vengai; Gandy, Jeffery C; Zhang, Chen; Ryman, Valerie E; Daniel Jones, A; Sordillo, Lorraine M

    2015-09-01

    Coliform mastitis is a severe and sometimes fatal disease characterized by an unregulated inflammatory response. The initiation, progression, and resolution of inflammatory responses are regulated, in part, by potent oxylipid metabolites derived from polyunsaturated fatty acids. The purpose of this study was to characterize the biosynthesis and diversity of oxylipid metabolites during acute bovine coliform mastitis. Eleven cows diagnosed with naturally occurring acute systemic coliform mastitis and 13 healthy control cows, matched for lactation number and days in milk, were selected for comparison of oxylipid and free fatty acid concentrations in both milk and plasma. Oxylipids and free fatty acids were quantified using liquid chromatography-tandem mass spectrometry. All polyunsaturated fatty acids quantified in milk were elevated during coliform mastitis with linoleic acid being the most abundant. Oxylipids synthesized through the lipoxygenase and cytochrome P450 pathways accounted for the majority of the oxylipid biosynthesis. This study demonstrated a complex and diverse oxylipid network, most pronounced at the level of the mammary gland. Substrate availability, biosynthetic pathways, and degree of metabolism influence the biosynthesis of oxylipids during bovine coliform mastitis. Further studies are required to identify targets for novel interventions that modulate oxylipid biosynthesis during coliform mastitis to optimize inflammation. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Effect of bovine manure on fecal coliform attachment to soil and soil particles of different sizes.

    PubMed

    Guber, Andrey K; Pachepsky, Yakov A; Shelton, Daniel R; Yu, Olivia

    2007-05-01

    Manure-borne bacteria can be transported in runoff as free cells, cells attached to soil particles, and cells attached to manure particles. The objectives of this work were to compare the attachment of fecal coliforms (FC) to different soils and soil fractions and to assess the effect of bovine manure on FC attachment to soil and soil fractions. Three sand fractions of different sizes, the silt fraction, and the clay fraction of loam and sandy clay loam soils were separated and used along with soil samples in batch attachment experiments with water-FC suspensions and water-manure-FC suspensions. In the absence of manure colloids, bacterial attachment to soil, silt, and clay particles was much higher than the attachment to sand particles having no organic coating. The attachment to the coated sand particles was similar to the attachment to silt and clay. Manure colloids in suspensions decreased bacterial attachment to soils, clay and silt fractions, and coated sand fractions, but did not decrease the attachment to sand fractions without the coating. The low attachment of bacteria to silt and clay particles in the presence of manure colloids may cause predominantly free-cell transport of manure-borne FC in runoff.

  13. Sanitary quality of the Jordan River in Salt Lake County, Utah

    USGS Publications Warehouse

    Thompson, K.R.

    1984-01-01

    This investigation of the sanitary quality of the Jordan River was conducted from July 1980 to October 1982 using indicator bacteria rather than specific pathogens. A serious sanitary problem was identified. Concentrations of total coliform bacteria often exceeded 5,000 colonies per 100 milliliters and concentrations of fecal coliform bacteria often exceeded 2,000 colonies per 100 milliliters in the lower reaches of the river. At times these levels were greatly exceeded. The most conspicuous aspect of the bacteriological data is its extreme variability. Seven waste-water treatment plants, seven major tributaries, numerous storm conduits, irrigation-return flow, and other sources all contribute to the dynamic system that determines the sanitary quality of the river. Because of this variability the sanitary quality of the river cannot be predicted at any one time. In general, concentrations of all three indicator bacteria increased in a downstream direction. Storm runoff from urban areas contributed large concentrations of indicator bacteria to the river. Regression analysis of 9 years of data collected at 1700 South Street showed a significant positive correlation between both fecal coliform and fecal streptococcal concentrations versus time. Concentrations of fecal coliform and fecal streptococci have both been increasing since 1974 at 1700 South Street. (USGS)

  14. Fluorescence-based multi-parameter approach to characterize dynamics of organic carbon, faecal bacteria and particles at alpine karst springs.

    PubMed

    Frank, Simon; Goeppert, Nadine; Goldscheider, Nico

    2018-02-15

    Karst springs, especially in alpine regions, are important for drinking water supply but also vulnerable to contamination, especially after rainfall events. This high variability of water quality requires rapid quantification of contamination parameters. Here, we used a fluorescence-based multi-parameter approach to characterize the dynamics of organic carbon, faecal bacteria, and particles at three alpine karst springs. We used excitation emission matrices (EEMs) to identify fluorescent dissolved organic material (FDOM). At the first system, peak A fluorescence and total organic carbon (TOC) were strongly correlated (Spearman's r s of 0.949), indicating that a large part of the organic matter is related to humic-like substances. Protein-like fluorescence and cultivation-based determination of coliform bacteria also had a significant correlation with r s =0.734, indicating that protein-like fluorescence is directly related to faecal pollution. At the second system, which has two spring outlets, the absolute values of all measured water-quality parameters were lower; there was a significant correlation between TOC and humic-like fluorescence (r s =0.588-0.689) but coliform bacteria and protein-like fluorescence at these two springs were not correlated. Additionally, there was a strong correlation (r s =0.571-0.647) between small particle fractions (1.0 and 2.0μm), a secondary turbidity peak and bacteria. At one of these springs, discharge was constant despite the reaction of all other parameters to the rainfall event. Our results demonstrated that i) all three springs showed fast and marked responses of all investigated water-quality parameters after rain events; ii) a constant discharge does not necessarily mean constant water quality; iii) at high contamination levels, protein-like fluorescence is a good indicator of bacterial contamination, while at low contamination levels no correlation between protein-like fluorescence and bacterial values was detected; and

  15. Water resources planning for rivers draining into Mobile Bay. Part 2: Non-conservative species transport models

    NASA Technical Reports Server (NTRS)

    April, G. C.; Liu, H. A.

    1975-01-01

    Total coliform group bacteria were selected to expand the mathematical modeling capabilities of the hydrodynamic and salinity models to understand their relationship to commercial fishing ventures within bay waters and to gain a clear insight into the effect that rivers draining into the bay have on water quality conditions. Parametric observations revealed that temperature factors and river flow rate have a pronounced effect on the concentration profiles, while wind conditions showed only slight effects. An examination of coliform group loading concentrations at constant river flow rates and temperature shows these loading changes have an appreciable influence on total coliform distribution within Mobile Bay.

  16. Microbioligical Hazard Contamination in Fermented Vegetables Sold in Local Markets in Cambodia.

    PubMed

    Chrun, Rithy; Hosotani, Yukie; Kawasaki, Susumu; Inatsu, Yasuhiro

    2017-01-01

     Fermented vegetables are common part of Cambodian diet. The food safety status for these foods has not been investigated. This study was conducted to evaluate the microbiological hazards that contaminated fermented vegetables. A total of 68 samples of fermented vegetables were purchased randomly from five wet markets in Phnom Penh. The conventional culture methods for microbiological analysis were used. Coliform bacteria (Escherichia coli, Cronobactersakazakii, and Enterobacter spp.), opportunistic non-Entrobacteriaceae, Enterococcus spp., Staphylococcus spp., and Listeria spp. were found in these fermented foods. The highest contamination rate of Enterococcus spp. was 34% of total fermented vegetable samples, followed by Bacillus spp. coliform bacteria and E. coli (31%, 24% and 10%, respectively). The potential foodborne pathogen, C. sakazakii, was identified in one sample. Fermented mixed vegetables showed higher contamination rate of coliform bacteria (50%) than fermented single-type vegetables (13%). The results showed that fermented vegetables sold in wet market are poor in hygiene. The stage in the processing chain where contamination occurred should be identified and basic sanitary practice should be enforced to improve the food safety of fermented vegetables in Cambodia.

  17. Comparison of fecal indicators with pathogenic bacteria and rotavirus in groundwater.

    PubMed

    Ferguson, Andrew S; Layton, Alice C; Mailloux, Brian J; Culligan, Patricia J; Williams, Daniel E; Smartt, Abby E; Sayler, Gary S; Feighery, John; McKay, Larry D; Knappett, Peter S K; Alexandrova, Ekaterina; Arbit, Talia; Emch, Michael; Escamilla, Veronica; Ahmed, Kazi Matin; Alam, Md Jahangir; Streatfield, P Kim; Yunus, Mohammad; van Geen, Alexander

    2012-08-01

    Groundwater is routinely analyzed for fecal indicators but direct comparisons of fecal indicators to the presence of bacterial and viral pathogens are rare. This study was conducted in rural Bangladesh where the human population density is high, sanitation is poor, and groundwater pumped from shallow tubewells is often contaminated with fecal bacteria. Five indicator microorganisms (E. coli, total coliform, F+RNA coliphage, Bacteroides and human-associated Bacteroides) and various environmental parameters were compared to the direct detection of waterborne pathogens by quantitative PCR in groundwater pumped from 50 tubewells. Rotavirus was detected in groundwater filtrate from the largest proportion of tubewells (40%), followed by Shigella (10%), Vibrio (10%), and pathogenic E. coli (8%). Spearman rank correlations and sensitivity-specificity calculations indicate that some, but not all, combinations of indicators and environmental parameters can predict the presence of pathogens. Culture-dependent fecal indicator bacteria measured on a single date did not predict total bacterial pathogens, but annually averaged monthly measurements of culturable E. coli did improve prediction for total bacterial pathogens. A qPCR-based E. coli assay was the best indicator for the bacterial pathogens. F+RNA coliphage were neither correlated nor sufficiently sensitive towards rotavirus, but were predictive of bacterial pathogens. Since groundwater cannot be excluded as a significant source of diarrheal disease in Bangladesh and neighboring countries with similar characteristics, the need to develop more effective methods for screening tubewells with respect to microbial contamination is necessary. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Correlation between chronic treatment with proton pump inhibitors and bacterial overgrowth in the stomach: any possible beneficial role for selected lactobacilli?

    PubMed

    Del Piano, Mario; Pagliarulo, Michela; Tari, Roberto; Carmagnola, Stefania; Balzarini, Marco; Lorenzini, Paola; Pane, Marco

    2014-01-01

    The inhibition of physiological gastric acid secretion induced by proton pump inhibitors (PPIs), the most widely used drugs in the world, may cause a significant bacterial overgrowth in the gastrointestinal tract as a side effect. This study was undertaken firstly to correlate PPI intake with concentration of specific bacterial groups in the stomach as well as possible Helicobacter pylori infection, and secondly to assess the efficacy of the 4 lactobacilli L. rhamnosus LR06 (DSM 21981), L. pentosus LPS01 (DSM 21980), L. plantarum LP01 (LMG P-21021), and L. delbrueckii subsp. delbrueckii LDD01 (DSM 22106) in the restoration of a physiological gastric barrier. Total bacteria, sulphite-reducing bacteria (SRB), total coliforms, and total lactobacilli were quantified in samples of gastric juice from 29 subjects taking PPIs for at least 3 months compared with 36 control subjects. The presence of H. pylori was also assessed.The subjects treated with PPIs with a concentration of total bacteria in the gastric juice higher than 10(5) cells/mL were selected for an intervention study with the 4 lactobacilli L. rhamnosus LR06, L. pentosus LPS01, L. plantarum LP01, and L. delbrueckii subsp. delbrueckii LDD01. After 15 days of supplementation, the same bacterial groups were quantified to compare these values with the baseline. No significant correlation was found between the presence of H. pylori and PPI intake. The baseline quantification of bacterial groups (log10 CFU/mL of gastric juice, PPI group vs. control) showed: total bacteria 8.35 versus 3.95 (P<0.001); total coliforms 4.98 versus 2.35 (P<0.001); SRB 5.71 versus 2.28 (P=0.065); and total lactobacilli 3.85 versus 2.20 (P=0.005). After 15 days of treatment with the 4 lactobacilli, the quantification of bacterial groups gave the following results: total bacteria 7.91 versus 8.35 at time zero (P=0.002); total coliforms 4.21 versus 4.98 at time zero (P<0.001); SRB 4.94 versus 5.71 at baseline (P=0.060); and total

  19. Vegetable Contamination by the Fecal Bacteria of Poultry Manure: Case Study of Gardening Sites in Southern Benin

    PubMed Central

    Atidégla, Séraphin C.; Huat, Joël; Agbossou, Euloge K.; Saint-Macary, Hervé; Glèlè Kakai, Romain

    2016-01-01

    A study was conducted in southern Benin to assess the contamination of vegetables by fecal coliforms, Escherichia coli, and fecal streptococci as one consequence of the intensification of vegetable cropping through fertilization with poultry manure. For this purpose, on-farm trials were conducted in 2009 and 2010 at Yodo-Condji and Ayi-Guinnou with three replications and four fertilization treatments including poultry manure and three vegetable crops (leafy eggplant, tomato, and carrot). Sampling, laboratory analyses, and counts of fecal bacteria in the samples were performed in different cropping seasons. Whatever the fertilization treatment, the logs of mean fecal bacteria count per g of fresh vegetables were variable but higher than AFNOR criteria. The counts ranged from 8 to 10 fecal coliforms, from 5 to 8 fecal streptococci, and from 2 to 6 Escherichia coli, whereas AFNOR criteria are, respectively, 0, 1, and 0. The long traditional use of poultry manure and its use during the study helped obtain this high population of fecal pathogens. Results confirmed that the contamination of vegetables by fecal bacteria is mainly due to the use of poultry manure. The use of properly composted poultry manure with innovative cropping techniques should help reduce the number and incidence of pathogens. PMID:27069914

  20. Increasing Efficiency of Fecal Coliform Testing Through EPA-Approved Alternate Method Colilert*-18

    NASA Technical Reports Server (NTRS)

    Cornwell, Brian

    2017-01-01

    The 21 SM 9221 E multiple-tube fermentation method for fecal coliform analysis requires a large time and reagent investment for the performing laboratory. In late 2010, the EPA approved an alternative procedure for the determination of fecal coliforms designated as Colilert*-18. However, as of late 2016, only two VELAP-certified laboratories in the Commonwealth of Virginia have been certified in this method.

  1. Fecal indicator bacteria persistence under natural conditions in an ice-covered river.

    PubMed Central

    Davenport, C V; Sparrow, E B; Gordon, R C

    1976-01-01

    Total coliform (TC), fecal coliform (FC), and fecal streptococcus (FS) survival characteristics, under natural conditions at 0 degrees C in an ice-covered river, were examined during February and March 1975. The membrane filter (MF) technique was used throughout the study, and the multiple-tube (MPN) method was used in parallel on three preselected days for comparative recovery of these bacteria. Survival was studied at seven sample stations downstream from all domestic pollution sources in a 317-km reach of the river having 7.1 days mean flow time (range of 6.0 to 9.1 days). The mean indicator bacteria densities decreased continuously at successive stations in this reach and, after adjustment for dilution, the most rapid die-off was found to occur during the first 1.9 days, followed by a slower decrease. After 7.1 days, the relative survival was TC less than FC less than FS, with 8.4%, 15.7%, and 32.8% of the initial populations remaining viable, respectively. These rates are higher than previously reported and suggest that the highest survival rates for these bacteria in receiving streams can be expected at 0 degree C under ice cover. Additionally, the FC-FS ratio was greater than 5 at all stations, indicating that this ratio may be useable for determining the source of fecal pollution in receiving streams for greater than 7 days flow time at low water temperatures. The MPN and MF methods gave comparable results for the TC and FS at all seven sample stations, with both the direct and verified MF counts within the 95% confidence limits of the respective MPNs in most samples, but generally lower than the MPN index. Although FC recovery on membrane filters was comparable results at stations near the pollution source. However, the results became more comparable with increasing flow time. The results of this study indicate that heat shock is a major factor in suppression of the FC counts on the membrane filters at 44.5 degree C. Heat shock may be minimized by extended

  2. The impact of rainfall and seasonal variability on the removal of bacteria by a point-of-use drinking water treatment intervention in Chennai, India.

    PubMed

    MacDonald, Morgan C; Juran, Luke; Jose, Jincy; Srinivasan, Sekar; Ali, Syed I; Aronson, Kristan J; Hall, Kevin

    2016-01-01

    Point-of-use water treatment has received widespread application in the developing world to help mitigate waterborne infectious disease. This study examines the efficacy of a combined filter and chemical disinfection technology in removing bacterial contaminants, and more specifically changes in its performance resulting from seasonal weather variability. During a 12-month field trial in Chennai, India, mean log-reductions were 1.51 for E. coli and 1.67 for total coliforms, and the highest concentration of indicator bacteria in treated water samples were found during the monsoon season. Analysis of variance revealed significant differences in the microbial load of indicator organisms (coliforms and E. coli) between seasons, storage time since treatment (TST), and samples with and without chlorine residuals. Findings indicate that the bacteriological quality of drinking water treated in the home is determined by a complex interaction of environmental and sociological conditions. Moreover, while the effect of disinfection was independent of season, the impact of storage TST on water quality was found to be seasonally dependent.

  3. In vitro growth inhibition of mastitis causing bacteria by phenolics and metal chelators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chew, B.P.; Tjoelker, L.W.; Tanaka, T.S.

    1985-11-01

    Antimicrobial activities of three phenolic compounds and four metal chelators were tested at 0, 250, 500, and 1000 ppm in vitro against four major mastitis-causing bacteria, Streptococcus agalactiae, Staphylococcus aureus, Klebsiella pnuemoniae, and Escherichia coli. Overall, butylated hydroxyanisole and tert-butylhydroquinone showed the greatest antimicrobial activity. These phenolics were bactericidal at 250 to 500 ppm against all four bacteria tested. The butylated hydroxytoluene was bactericidal against the gram-positive bacteria but was ineffective against the coliforms. At 250 ppm, disodium ethylenediaminetetraacetic acid was bactericidal against the gram-positive bacteria but much less effective against the gram-negatives. However, diethylene-triaminepentaacetic acid was more growth inhibitorymore » than ethylenediaminetetraacetic acid against the gram-negative bacteria and especially against Escherichia coli. All other compounds were generally much less effective or ineffective against all four microorganisms. Therefore, butylated hydroxyanisole, butylated hydroxytoluene, tert-butylhydroquinone, ethylenediaminetetraacetic acid, and diethylenetriaminepentaacetic acid may have practical implications in the prevention or treatment of bovine mastitis.« less

  4. [The method and result analyses of pathogenic bacteria culture on chronic periprosthetic joint infection after total knee arthroplasty and total hip arthroplasty].

    PubMed

    Ji, Baochao; Xu, Enjie; Cao, Li; Yang, Desheng; Xu, Boyong; Guo, Wentao; Aili, Rehei

    2015-02-01

    To analyze the results of pathogenic bacteria culture on chronic periprosthetic joint infection after total knee arthroplasty (TKA) and total hip arthroplasty (THA). The medical data of 23 patients with chronic periprosthetic joint infection after TKA or THA from September 2010 to March 2014 were reviewed. Fifteen cases of TKA and 8 cases of THA were included in this study. There were 12 male and 11 female patients with the mean age of 62 years (range from 32 to 79 years), and among them 9 patients with sinus. All patients discontinued antibiotic therapy for a minimum of 2 weeks before arthrocentesis, taking pathogenic bacteria culture and antimicrobial susceptibility test by using synovial fluid taken preoperatively and intraoperatively of revision. Common pathogenic bacteria culture and pathological biopsy were taken on tissues intraoperatively of revision. Culture-negative specimens were prolonged the period of incubation for 2 weeks. The overall culture-positive rate of all 23 patients for 1 week before revision was 30.4% (7/23), and the positive rate of culture-negative samples which prolonged for 2 weeks was 39.1% (9/23). The overall culture-positive rate of patients for 1 week intraoperatively of revision was 60.9% (14/23), and the positive rate of culture-negative samples which prolonged for 2 weeks was 82.6% (19/23). The incubation results of 7 cases (30.4%) preoperatively conformed to that of intraoperation. The culture-positive rate of pathogenic bacteria culture can be increased evidently by discontinuing antimicrobial therapy for a minimum of 2 weeks prior to the definite diagnosis.

  5. Isolation and characterization of coliforms from glacial ice and water in Canada's High Arctic.

    PubMed

    Dancer, S J; Shears, P; Platt, D J

    1997-05-01

    Ellesmere Island is the northern most member of the Canadian Arctic Archipelago with over one-third of the land mass covered by ice. A joint services expedition to the island's Blue Mountains offered a unique opportunity for microbiological studies of resident bacteria in an environment uninhabited by man. Over 100 samples of water and ice were collected from stream, lake and glacier and the filtrate cultured under canvas. Bacterial growth was harvested onto swabs for transport back to the UK and 50 coliforms chosen at random for identification and antibiotic susceptibility testing. Most of the glacial strains were capsulated, pigmented and some over 2000 years old. Genera such as Serratia, Enterobacter, Klebsiella and Yersinia were found; speciation was inconclusive and some organisms remain unidentified. Ampicillin resistance was evident in 80% of water isolates as opposed to 30% of the glacial organisms, but the isolates were generally exquisitely susceptible to antibiotics. The facility for ampicillin resistance did not appear to be transferable. Plasmid DNA was found in 33% of the glacial organisms and over 50% of the water isolates. Similar profiles were identified within and apparently between species and required plasmid restriction analysis to help establish identity. Plasmid-free Serratia spp. were subjected to genomic fingerprinting. Indistinguishable patterns were found within sets of isolates both widely spaced by distance and collection date and it was postulated that coliforms able to survive an Arctic environment had spread extensively throughout the expedition area. In conclusion, this study contributes towards knowledge of naturally occurring antibiotic resistance, confirms the presence of plasmids and genotypic data provided evidence that potentially ancient organisms from glaciers can be cultured from water samples significantly distant.

  6. Occurrence of Coliform and Escherichia coli Contamination and Absence of Escherichia coli O157:H7 on Romaine Lettuce from Retail Stores in the Upper Midwest.

    PubMed

    Greve, Josephine D; Zietlow, Mark S; Miller, Kevin M; Ellingson, Jay L E

    2015-09-01

    A total of 720 whole, romaine lettuce heads were purchased from retail locations in the Upper Midwest and assessed for coliform and Escherichia coli contamination and for the presence of E. coli O157:H7. During a 16-month period (August 2010 through December 2011), coliform and E. coli counts were enumerated on Petrifilm, and the presence of E. coli O157:H7 and the virulence gene eae was evaluated by real-time PCR (qPCR). Over half (400 of 720) of the lettuce samples were processed with an immunomagnetic separation step before the qPCR assay. All retail lettuce samples were negative for E. coli O157:H7 when tested with the R.A.P.I.D. LT qPCR targeting a region of the O-antigen, and only two (0.28%) were positive for the eae gene when tested with LightCycler qPCR. On Petrifilm, coliform counts of most lettuce samples (96.4%) were between <10(1) and 10(3) CFU/g, and E. coli counts for nearly all lettuce samples (98.2%) were <10(1) CFU/g. No seasonal trend in coliform and E. coli counts was observed throughout the examination period nor was a difference in coliform counts observed between packaged and nonpackaged lettuce heads. These results contribute to the limited recorded data and understanding of microbial contamination of whole romaine lettuce heads purchased from retail locations, specifically revealing the absence of E. coli O157:H7 and low levels of contamination with coliforms and other E. coli strains.

  7. False positive fecal coliform in biosolid samples assayed using A-1 medium.

    PubMed

    Baker, Katherine H; Redmond, Brady; Herson, Diane S

    2005-01-01

    Two most probable number (MPN) methods-lauryl tryptose broth with Escherichia coli broth confirmation and direct A-1 broth incubation (A-1)--were compared for the enumeration of fecal coliform in lime-treated biosolid. Fecal coliform numbers were significantly higher using the A-1 method. Analysis of positive A-1 tubes, however, indicated that a high percentage of these were false positives. Therefore, the use of A-1 broth for 40 CFR Part 503 Pathogen Reduction (CFR, 1993) compliance testing is not recommended.

  8. Survival of infectious Poliovirus-1 in river water compared to the persistence of somatic coliphages, thermotolerant coliforms and Poliovirus-1 genome.

    PubMed

    Skraber, S; Gassilloud, B; Schwartzbrod, L; Gantzer, C

    2004-07-01

    The microbiological quality of water is currently assessed by search for fecal bacteria indicators. There is, however, a body of knowledge demonstrating that bacterial indicators are less resistant to environmental factors than human pathogenic viruses and therefore underestimate the viral risk. As river water is often used as a resource for drinking water production, it is particularly important to obtain a valid estimation of the health hazard, including specific viral risk. This work was conducted to compare the survival of infectious Poliovirus-1 used as a pathogenic virus model to the persistence of, on the one hand, thermotolerant coliforms commonly used as indicators and on the other hand, to somatic coliphages and Poliovirus-1 genome considered as potential indicators. We studied the behavior of infectious Poliovirus-1 and the three (potential) indicators of viral contamination in river water at three different temperatures (4 degrees C,18 degrees C and 25 degrees C). This experiment was performed twice with river water sampled at two different periods, once in winter and once in summer. Our results showed that the survival of thermotolerant coliforms can be 1.5-fold lower than infectious Poliovirus-1. In contrast, under all our experimental conditions, somatic coliphages and Poliovirus-1 genome persisted longer than infectious Poliovirus-1, surviving, respectively, 2-6-fold and about 2-fold longer than infectious Poliovirus-1. According to our results exclusively based on survival capacity, somatic coliphages and viral genome, unlike thermotolerant coliforms appear to be better indicators of viral contamination in river water. Moreover, the disappearance of viral genome is well-correlated to that one of infectious virus irrespective of the conditions tested.

  9. Seasonal variability of faecal indicator bacteria numbers and die-off rates in the Red River basin, North Viet Nam

    NASA Astrophysics Data System (ADS)

    Nguyen, Huong Thi Mai; Le, Quynh Thi Phuong; Garnier, J.; Janeau, J.-L.; Rochelle-Newall, E.

    2016-02-01

    The Red River is the second largest river in Viet Nam and constitutes the main water source for a large percentage of the population of North Viet Nam. Here we present the results of an annual survey of Escherichia coli (EC) and Total Coliforms (TC) in the Red River basin, North Viet Nam. The objective of this work was to obtain information on faecal indicator bacteria (FIB) numbers over an annual cycle and, secondly, to determine the die-off rates of these bacterial indicators. Monthly observations at 10 stations from July 2013-June 2014 showed that TC and EC reached as high as 39100 cfu (colony forming units) 100 ml-1 and 15300 colonies 100 ml-1, respectively. We observed a significant seasonal difference for TC (p < 0.05) with numbers being higher during the wet season. In contrast, no significant seasonal difference was found for EC. The FIB die-off rates ranged from 0.01 d-1 to a maximum of 1.13 d-1 for EC and from 0.17 d-1 to 1.33 d-1 for TC. Die-off rates were significantly higher for free bacteria than for total (free + particle attached) bacteria, suggesting that particle attachment provided a certain level of protection to FIB in this system.

  10. Seasonal variability of faecal indicator bacteria numbers and die-off rates in the Red River basin, North Viet Nam.

    PubMed

    Nguyen, Huong Thi Mai; Le, Quynh Thi Phuong; Garnier, J; Janeau, J-L; Rochelle-Newall, E

    2016-02-12

    The Red River is the second largest river in Viet Nam and constitutes the main water source for a large percentage of the population of North Viet Nam. Here we present the results of an annual survey of Escherichia coli (EC) and Total Coliforms (TC) in the Red River basin, North Viet Nam. The objective of this work was to obtain information on faecal indicator bacteria (FIB) numbers over an annual cycle and, secondly, to determine the die-off rates of these bacterial indicators. Monthly observations at 10 stations from July 2013-June 2014 showed that TC and EC reached as high as 39100 cfu (colony forming units) 100 ml(-1) and 15300 colonies 100 ml(-1), respectively. We observed a significant seasonal difference for TC (p < 0.05) with numbers being higher during the wet season. In contrast, no significant seasonal difference was found for EC. The FIB die-off rates ranged from 0.01 d(-1) to a maximum of 1.13 d(-1) for EC and from 0.17 d(-1) to 1.33 d(-1) for TC. Die-off rates were significantly higher for free bacteria than for total (free + particle attached) bacteria, suggesting that particle attachment provided a certain level of protection to FIB in this system.

  11. An assessment of fecal indicator and other bacteria from an urbanized coastal lagoon in the City of Los Angeles, California, USA.

    PubMed

    Dorsey, John H; Carmona-Galindo, Víctor D; Leary, Christopher; Huh, Julie; Valdez, Jennifer

    2013-03-01

    A study was performed in Del Rey Lagoon, City of Los Angeles, to determine if the lagoon was as a source or sink for fecal indicator bacteria (FIB: total coliforms, Escherichia coli, enterococci) and to screen for the presence of other potentially pathogenic bacteria. The lagoon receives tidal flows from the adjacent Ballona Estuary whose water usually is contaminated with FIB originating from the highly urbanized Ballona Creek Watershed. During 16 sampling events from February 2008 through March 2009, replicate water samples (n = 3) were collected 1 h prior to the high tide and 1 h prior to the following low tide. FIB concentrations were measured by the defined substrate method (IDEXX, Westbrook, Me) followed by culturing of bacterial isolates sampled from positive IDEXX Quanti-Tray wells and were identified using the Vitek 2 Compact (bioMérieux, Durham, NC). Mean concentrations of FIB often differed by an order of magnitude from flood to ebb flow conditions. The lagoon tended to act as a sink for total coliforms based on the ratio of mean flood to ebb densities (R (F/E)) >1.0 during 56 % of the sampling events and during ebb flows, as a source for E. coli and enterococci (R (F/E) <1.69 % of events). Approximately 54 species were identified from 277 isolates cultured from the IDEXX Quanti-Trays. Of these, 54 % were species known to include pathogenic strains that can be naturally occurring, introduced in runoff, or originated from other sources. Diversity and cluster analyses indicated a dynamic assemblage that changes in species composition with day-to-day fluctuations as well as tidal action. The concept of monitoring the lagoon and estuary as a sentinel habitat for pathogenic assemblages is discussed.

  12. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    PubMed

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (<0.10mg/L) with the pH ranging between 5.5 and 7.3 and turbidity between 0.14-1.76 NTU. Since contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (<0.10mg/ L) in all samples as well as in both tap water and commercially bottled drinking water, with the pH ranged between 5.5-7.3, ineffective disinfection of water source as a contributing factor to such high counts of faecal coliforms in ice cubes also could not be ruled out. Therefore, a periodical, yet comprehensive check on the food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  13. Thermotolerant coliforms are not a good surrogate for Campylobacter spp. in environmental water.

    PubMed

    St-Pierre, Karen; Lévesque, Simon; Frost, Eric; Carrier, Nathalie; Arbeit, Robert D; Michaud, Sophie

    2009-11-01

    This study aimed to assess the importance of quantitatively detecting Campylobacter spp. in environmental surface water. The prevalence and the quantity of Campylobacter spp., thermotolerant coliforms, and Escherichia coli in 2,471 samples collected weekly, over a 2-year period, from 13 rivers and 12 streams in the Eastern Townships, Québec, Canada, were determined. Overall, 1,071 (43%), 1,481 (60%), and 1,463 (59%) samples were positive for Campylobacter spp., thermotolerant coliforms, and E. coli, respectively. There were weak correlations between the weekly distributions of Campylobacter spp. and thermotolerant coliforms (Spearman's rho coefficient = 0.27; P = 0.008) and between the quantitative levels of the two classes of organisms (Kendall tau-b correlation coefficient = 0.233; P < 0.0001). Well water samples from the Eastern Townships were also tested. Five (10%) of 53 samples from private surface wells were positive for Campylobacter jejuni, of which only 2 were positive for thermotolerant coliforms. These findings suggest that microbial monitoring of raw water by using only fecal indicator organisms is not sufficient for assessing the occurrence or the load of thermophilic Campylobacter spp. Insights into the role of environmental water as sources for sporadic Campylobacter infection will require genus-specific monitoring techniques.

  14. 75 FR 32295 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... Identification of Coliform Bacteria and Escherichia coli in Finished Waters, January 2007, Version 1.1... Membrane Filter Test Method for Detection and Identification of Coliform Bacteria and Escherichia coli in... Detection and Identification of Coliform Bacteria and Escherichia coli in Finished Waters. November, 2000...

  15. Survival, transport, and sources of fecal bacteria in streams and survival in land-applied poultry litter in the upper Shoal Creek basin, southwestern Missouri, 2001-2002

    USGS Publications Warehouse

    Schumacher, John G.

    2003-01-01

    Densities of fecal coliform bacteria along a 5.7-mi (mile) reach of Shoal Creek extending upstream from State Highway 97 (site 3) to State Highway W (site 2) and in two tributaries along this reach exceeded the Missouri Department of Natural Resources (MDNR) standard of 200 col/100 mL (colonies per 100 milliliters) for whole-body contact recreation. A combination of techniques was used in this report to provide information on the source, transport, and survival of fecal bacteria along this reach of Shoal Creek. Results of water-quality samples collected during dye-trace and seepage studies indicated that at summer low base-flow conditions, pastured cattle likely were a substantial source of fecal bacteria in Shoal Creek at the MDNR monitoring site (site 3) at State Highway 97. Using repeat element Polymerase Chain Reaction (rep-PCR), cattle were the presumptive source of about 50 percent of the Escherichia coli (E. coli) isolates in water samples from site 3. Cattle, horses, and humans were the most common presumptive source of E. coli isolates at sites further upstream. Poultry was identified by rep-PCR as a major source of E. coli in Pogue Creek, a tributary in the upper part of the study area. Results of the rep-PCR were in general agreement with the detection and distribution of trace concentrations of organic compounds commonly associated with human wastewater, such as caffeine, the antimicrobial agent triclosan, and the pharmaceutical compounds acetaminophen and thiabendazole (a common cattle anthelmintic). Significant inputs of fecal bacteria to Shoal Creek occurred along a 1.6-mi reach of Shoal Creek immediately upstream from site 3. During a 36-hour period in July 2001, average densities of fecal coliform and E. coli bacteria increased from less than or equal to 500 col/100 mL upstream from this stream reach (sample site 2c) to 2,100 and 1,400 col/100 mL, respectively, at the MDNR sampling site. Fecal bacteria densities exhibited diurnal variability at all

  16. Quantitative Real-Time PCR Analysis of Total Propidium Monazide -Resistant Fecal Indicator Bacteria in Wastewater

    EPA Science Inventory

    A real-time quantitative PCR (qPCR) method and a modification of this method incorporating pretreatment of samples with propidium monoazide (PMA) were evaluated for respective analyses of total and presumptively viable Enterococcus and Bacteroidales fecal indicator bacteria. Thes...

  17. Fecal-indicator bacteria in the Yakima River Basin, Washington-An examination of 1999 and 2000 synoptic-sampling data and their relation to historical data

    USGS Publications Warehouse

    Morace, Jennifer L.; McKenzie, Stuart W.

    2002-11-27

    Looking forward relative to future monitoring goals, research needs, and best management practice development, four hypotheses that deal with processes and sources of bacteria were identified: (1) overland runoff transports bacteria from land surfaces to streams, (2) bacteria in the water column tend to associate with suspended matter, (3) with increasing densities of warm-blooded animals, the likelihood of fecal-coliform contamination in streams also increases, and (4) identifi- cation of bacterial sources is difficult, but must be attempted for remediation to be possible. 

  18. Simultaneous determination of the total number of aquatic bacteria and the number thereof involved in respiration.

    PubMed Central

    Zimmermann, R; Iturriaga, R; Becker-Birck, J

    1978-01-01

    The electron transport system of respiring organisms reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan. Respiring bacteria deposit accumulated INT-formazan intracellularly as dark red spots. Corresponding to electron transport system activity, these deposits attain a size and a degree of optical density which allows them to be examined by light microscopy. If polycarbonate filters and epifluorescence microscopy are applied to analyze an INT-treated water sample, it is possible to differentiate between respiring and apparently nonrespiring bacteria. This differentiation, which permits determinations of the total number of bacteria and the proportion thereof involved in respiration, is realized directly within one and the same microscopic image. Initial applications of the present method for hydrobiological purposes showed that the proportion of respiring aquatic bacteria ranged between 6 to 12% (samples taken from coastal areas of the Baltic Sea) and 5 to 36% (samples taken from freshwater lakes and ponds). Cells of 1.6 to 2.4 micrometer (freshwater) and 0.4 micrometer (Baltic Sea) account for the highest proportion of respiring bacteria. Images PMID:367268

  19. Removal of contaminants and pathogens from secondary effluents using intermittent sand filters.

    PubMed

    Bali, Mahmoud; Gueddari, Moncef; Boukchina, Rachid

    2011-01-01

    Intermittent infiltration percolation of wastewater through unsaturated sand bed is an extensive treatment technique aimed at eliminating organic matter, oxidizing ammonium and removing pathogens. The main purpose of this study was to determine the depuration efficiencies of a sand filter to remove contaminants from secondary wastewater effluents. Elimination of pathogenic bacteria (total and faecal coliforms, streptococci) and their relationship with the filter depth were investigated. Results showed a high capacity of infiltration percolation process to treat secondary effluents. Total elimination of suspended solids was obtained. Mean removal rate of BOD(5) and COD was more than 97 and more than 81%, respectively. Other water quality parameters such as NH(4)-N, TKN and PO(4)-P showed significant reduction except NO(3)-N which increased significantly in the filtered water. Efficiency of pathogenic bacteria removal was shown to mainly depend on the filter depth. Average reductions of 2.35 log total coliforms, 2.47 log faecal coliforms and 2.11 log faecal streptococci were obtained. The experimental study has shown the influence of the temperature on the output purification of infiltration percolation process.

  20. Examination and characterization of distribution system biofilms.

    PubMed Central

    LeChevallier, M W; Babcock, T M; Lee, R G

    1987-01-01

    Investigations concerning the role of distribution system biofilms on water quality were conducted at a drinking water utility in New Jersey. The utility experienced long-term bacteriological problems in the distribution system, while treatment plant effluents were uniformly negative for coliform bacteria. Results of a monitoring program showed increased coliform levels as the water moved from the treatment plant through the distribution system. Increased coliform densities could not be accounted for by growth of the cells in the water column alone. Identification of coliform bacteria showed that species diversity increased as water flowed through the study area. All materials in the distribution system had high densities of heterotrophic plate count bacteria, while high levels of coliforms were detected only in iron tubercles. Coliform bacteria with the same biochemical profile were found both in distribution system biofilms and in the water column. Assimilable organic carbon determinations showed that carbon levels declined as water flowed through the study area. Maintenance of a 1.0-mg/liter free chlorine residual was insufficient to control coliform occurrences. Flushing and pigging the study area was not an effective control for coliform occurrences in that section. Because coliform bacteria growing in distribution system biofilms may mask the presence of indicator organisms resulting from a true breakdown of treatment barriers, the report recommends that efforts continue to find methods to control growth of coliform bacteria in pipeline biofilms. Images PMID:3435140

  1. Drug Resistance and R Factors in the Bowel Bacteria of London Patients before and after Admission to Hospital

    PubMed Central

    Datta, Naomi

    1969-01-01

    The content of drug-resistant coliform bacteria in faecal specimens collected before admission from patients awaiting non-urgent surgery were compared with specimens collected in hospital. Resistant strains of Escherichia coli were isolated from 52% of preadmission specimens and were present in large numbers in 28%. Tetracycline, sulphonamide, and streptomycin resistance were commonest: 60% of resistant strains carried transmissible R factors and multiple resistance was commoner than single. No characteristically resistant intestinal bacteria of any genera were found in hospital specimens as compared with those from outside. PMID:4976456

  2. Evaluation of a clay-based acidic bedding conditioner for dairy cattle bedding.

    PubMed

    Proietto, R L; Hinckley, L S; Fox, L K; Andrew, S M

    2013-02-01

    This study investigated the effects of a clay-based acidic bedding conditioner on sawdust bedding pH, dry matter (DM), environmental pathogen counts, and environmental bacterial counts on teat ends of lactating dairy cows. Sixteen lactating Holstein cows were paired based on parity, days in milk, milk yield, and milk somatic cell count, and were negative for the presence of an intramammary pathogen. Within each pair, cows were randomly assigned to 1 of 2 treatments with 3-wk periods in a crossover design. Treatment groups consisted of 9 freestalls per group bedded with either untreated sawdust or sawdust with a clay-based acidic bedding conditioner, added at 3- to 4-d intervals over each 21-d period. Bedding and teat ends were aseptically sampled on d 0, 1, 2, 7, 14, and 21 for determination of environmental bacterial counts. At the same time points, bedding was sampled for DM and pH determination. The bacteria identified in the bedding material were total gram-negative bacteria, Streptococcus spp., and coliform bacteria. The bacteria identified on the teat ends were Streptococcus spp., coliform bacteria, and Klebsiella spp. Teat end score, milk somatic cell count, and intramammary pathogen presence were measured weekly. Bedding and teat cleanliness, environmental high and low temperatures, and dew point data were collected daily. The bedding conditioner reduced the pH, but not the DM, of the sawdust bedding compared with untreated sawdust. Overall environmental bacterial counts in bedding were lower for treated sawdust. Total bacterial counts in bedding and on teat ends increased with time over both periods. Compared with untreated sawdust, the treated bedding had lower counts of total gram-negative bacteria and streptococci, but not coliform counts. Teat end bacterial counts were lower for cows bedded on treated sawdust for streptococci, coliforms, and Klebsiella spp. compared with cows bedded on untreated sawdust. The clay-based acidic bedding conditioner

  3. Rainfall-Induced Release of Fecal Coliforms and Other Manure Constituents: Comparison and Modeling▿

    PubMed Central

    Guber, A. K.; Shelton, D. R.; Pachepsky, Y. A.; Sadeghi, A. M.; Sikora, L. J.

    2006-01-01

    Modeling release of fecal coliforms is an important component of fate and transport simulations related to environmental water quality. Manure constituents other than fecal coliforms may serve as natural tracers of fecal contamination provided that their release from manure to runoff is similar to the fecal coliform release. The objectives of this work were to compare release of fecal coliforms (FC), chloride (Cl−), organic carbon (OC), and water-soluble phosphorus (P) from dissolving manure and to assess the performance of three models in describing the observed release. Bovine manure was applied on 0.5- by 0.3-m bare and vegetated subplots with 20% slope on sandy loam and clay loam soils. Concentrations of Cl−, FC, OC, and P were measured in runoff collected from troughs at the edges of the subplots at 5-min intervals during 1-h rainfall simulations. The one-parametric exponential model and two-parametric Vadas-Kleinman-Sharpley model and Bradford-Schijven model were fitted to the data. The Bradford-Schijven model had uncorrelated parameters, one of which was linearly related to the irrigation rate, and another parameter reflected the presence or the absence of vegetation. Kinetics of the FC release from manure was similar to the release kinetics of P and OC. The Bradford-Schijven model is recommended to simulate the release of manure constituents. PMID:17028232

  4. Use of natural compounds to improve the microbial stability of Amaranth-based homemade fresh pasta.

    PubMed

    Del Nobile, M A; Di Benedetto, N; Suriano, N; Conte, A; Lamacchia, C; Corbo, M R; Sinigaglia, M

    2009-04-01

    A study on the use of natural antimicrobial compounds to improve the microbiological stability of refrigerated amaranth-based homemade fresh pasta is presented in this work. In particular, the antimicrobial activity of thymol, lemon extract, chitosan and grapefruit seed extract (GFSE) has been tested against mesophilic and psychrotrophic bacteria, total coliforms, Staphylococcus spp., yeasts and moulds. A sensory analysis on both fresh and cooked pasta was also run. Results suggest that chitosan and GFSE strongly increase the microbial acceptability limit of the investigated spoilage microorganisms, being the former the most effective. Thymol efficiently reduces the growth of mesophilic bacteria, psychrotrophic bacteria and Staphylococcus spp., whereas it does not affect, substantially, the growth cycle of total coliforms. Lemon extract is the less effective in preventing microbial growth. In fact, it is able to delay only total mesophilic and psychrotrophic bacterial evolution. From a sensorial point of view no significant differences were recorded between the control samples and all the types of loaded amaranth-based pasta.

  5. Multidrug-Resistant Bacteria Isolated from Surface Water in Bassaseachic Falls National Park, Mexico.

    PubMed

    Delgado-Gardea, Ma Carmen E; Tamez-Guerra, Patricia; Gomez-Flores, Ricardo; Zavala-Díaz de la Serna, Francisco Javier; Eroza-de la Vega, Gilberto; Nevárez-Moorillón, Guadalupe Virginia; Pérez-Recoder, María Concepción; Sánchez-Ramírez, Blanca; González-Horta, María Del Carmen; Infante-Ramírez, Rocío

    2016-06-16

    Bacterial pathogens are a leading cause of waterborne disease, and may result in gastrointestinal outbreaks worldwide. Inhabitants of the Bassaseachic Falls National Park in Chihuahua, Mexico show seasonal gastroenteritis problems. This aim of this study was to detect enteropathogenic microorganisms responsible for diarrheal outbreaks in this area. In 2013, 49 surface water samples from 13 selected sampling sites along the Basaseachi waterfall and its main rivers, were collected during the spring, summer, autumn, and winter seasons. Fecal and total coliform counts were determined using standard methods; the AutoScan-4 system was used for identification of isolates and the antibiotic resistance profile by challenging each organism using 21 antibiotics. Significant differences among seasons were detected, where autumn samples resulted in the highest total (p < 0.05) and fecal (p < 0.001) coliform counts, whereas the lowest total coliform counts were recorded in spring. Significant differences between sampling sites were observed, where samples from sites 6, 8, and 11 had the highest total coliform counts (p < 0.009), whereas samples from site 9 exhibited the lowest one. From the microbiological analysis, 33 bacterial isolates from 13 different sites and four sampling seasons were selected; 53% of isolates were resistant to at least one antibiotic, and 15% exhibited a multidrug resistance (MDB) phenotype. MDB were identified as Klebsiella oxytoca (two out of four identified isolates), Escherichia coli (2/7), and Enterobacter cloacae (1/3). In addition, some water-borne microorganisms exhibited resistance to cefazoline, cefuroxime, ampicillin, and ampicillin-sulbactam. The presence of these microorganisms near rural settlements suggests that wastewater is the contamination source, providing one possible transmission mechanism for diarrheal outbreaks.

  6. Multidrug-Resistant Bacteria Isolated from Surface Water in Bassaseachic Falls National Park, Mexico

    PubMed Central

    Delgado-Gardea, Ma. Carmen E.; Tamez-Guerra, Patricia; Gomez-Flores, Ricardo; Zavala-Díaz de la Serna, Francisco Javier; Eroza-de la Vega, Gilberto; Nevárez-Moorillón, Guadalupe Virginia; Pérez-Recoder, María Concepción; Sánchez-Ramírez, Blanca; González-Horta, María del Carmen; Infante-Ramírez, Rocío

    2016-01-01

    Bacterial pathogens are a leading cause of waterborne disease, and may result in gastrointestinal outbreaks worldwide. Inhabitants of the Bassaseachic Falls National Park in Chihuahua, Mexico show seasonal gastroenteritis problems. This aim of this study was to detect enteropathogenic microorganisms responsible for diarrheal outbreaks in this area. In 2013, 49 surface water samples from 13 selected sampling sites along the Basaseachi waterfall and its main rivers, were collected during the spring, summer, autumn, and winter seasons. Fecal and total coliform counts were determined using standard methods; the AutoScan-4 system was used for identification of isolates and the antibiotic resistance profile by challenging each organism using 21 antibiotics. Significant differences among seasons were detected, where autumn samples resulted in the highest total (p < 0.05) and fecal (p < 0.001) coliform counts, whereas the lowest total coliform counts were recorded in spring. Significant differences between sampling sites were observed, where samples from sites 6, 8, and 11 had the highest total coliform counts (p < 0.009), whereas samples from site 9 exhibited the lowest one. From the microbiological analysis, 33 bacterial isolates from 13 different sites and four sampling seasons were selected; 53% of isolates were resistant to at least one antibiotic, and 15% exhibited a multidrug resistance (MDB) phenotype. MDB were identified as Klebsiella oxytoca (two out of four identified isolates), Escherichia coli (2/7), and Enterobacter cloacae (1/3). In addition, some water-borne microorganisms exhibited resistance to cefazoline, cefuroxime, ampicillin, and ampicillin-sulbactam. The presence of these microorganisms near rural settlements suggests that wastewater is the contamination source, providing one possible transmission mechanism for diarrheal outbreaks. PMID:27322297

  7. 33 CFR 159.127 - Safety coliform count: Recirculating devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety coliform count: Recirculating devices. 159.127 Section 159.127 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159...

  8. Bacteriological quality of drinking water in Nyala, South Darfur, Sudan.

    PubMed

    Abdelrahman, Amira Ahmed; Eltahir, Yassir Mohammed

    2011-04-01

    The objective of this study was to determine the bacterial contaminations in drinking water in Nyala city, South Darfur, Sudan with special reference to the internally displaced people camps (IDPs). Two hundred and forty water samples from different sites and sources including bore holes, hand pumps, dug wells, water points, water reservoir and household storage containers were collected in 2009. The most probable number method was used to detect and count the total coliform, faecal coliform and faecal enterococci. Results revealed that the three indicators bacteria were abundant in all sources except water points. Percentages of the three indicators bacteria count above the permissible limits for drinking water in all samples were 46.4% total coliform, 45.2% faecal coliform and 25.4% faecal enterococci whereas the highest count of the indicators bacteria observed was 1,600 U/100 ml water. Enteric bacteria isolated were Escherichia coli (22.5%), Enterococcus faecalis (20.42%), Klebsiella (15.00%), Citrobacter (2.1%) and Enterobacter (3.33%). The highest contamination of water sources was observed in household storage containers (20%) followed by boreholes (11.25%), reservoirs (6.24%), hand pumps (5.42%) and dug wells (2.49%). Contamination varied from season to season with the highest level in autumn (18.33%) followed by winter (13.75%) and summer (13.32%), respectively. All sources of water in IDP camps except water points were contaminated. Data suggested the importance of greater attention for household contamination, environmental sanitation control and the raise of awareness about water contamination.

  9. Microorganisms in bioaerosol emissions from wastewater treatment plants during summer at a Mediterranean site.

    PubMed

    Karra, Styliani; Katsivela, Eleftheria

    2007-03-01

    Measurements were conducted at a Mediterranean site (latitude 35 degrees 31' north and longitude 24 degrees 03' east) during summer, to study the concentration of microorganisms emitted from a wastewater treatment plant under intensive solar radiation (520-840 W/m2) and at elevated air temperatures (25-31 degrees C). Air samples were taken with the Air Sampler MAS 100 (Merck) at each stage of an activated-sludge wastewater treatment (pretreatment, primary settling tanks, aeration tanks, secondary settling tanks, chlorination, and sludge processors). Cultivation methods based on the viable counts of mesophilic heterotrophic bacteria, as well as of indicator microorganisms of faecal contamination (total and faecal coliforms and enterococci), and fungi were performed. During air sampling, temperature, solar radiation, relative humidity and wind speed were measured. The highest concentrations of airborne microorganisms were observed at the aerated grit removal of wastewater at the pretreatment stage. A gradual decrease of bioaerosol emissions was observed during the advanced wastewater treatment from the pretreatment to the primary, secondary and tertiary treatment (97.4% decrease of mesophilic heterotrophic bacteria, and 100% decrease of total coliforms, faecal coliforms and enterococci), 95.8% decrease of fungi. The concentration of the airborne microorganisms at the secondary and tertiary treatment of the wastewater was lower than in the outdoor control. At the same time, the reduction of the microbial load at the waste sludge processors was 19.7% for the mesophilic heterotrophic bacteria, 99.4% for the total coliforms, and 100% for the faecal coliforms and the enterococci, 84.2% for the fungi. The current study concludes that the intensive solar radiation, together with high ambient temperatures, as well as optimal wastewater treatment are the most important factors for low numbers of microbes in the air.

  10. Data for distribution of various species of fecal coliforms in urban, rural and private drinking water sources in ten years period - A case study: Kermanshah, Iran.

    PubMed

    Davoodi, Reza; Pirsaheb, Meghdad; Karimyan, Kamaladdin; Gupta, Vinod Kumar; Takhtshahi, Ali Reza; Sharafi, Hooshmand; Moradi, Masoud

    2018-06-01

    This study was aimed to investigate the distribution of various species of fecal coliform in urban, rural and private drinking water sources of Kermanshah, in the west of Iran. For this study, data of ten years period (2006-2016) assessments of microbial quality regarding various species of Fecal coliforms was taken from health centers associated with urban, rural and private resources of Kermanshah city. A total number of 8643 samples were taken, 1851 samples from rural, 365 from urban and 4834 from private resources. The results showed that Fecal coliforms , Escherichia coli ( E. coli ) had the widest distribution in all urban, rural and private water resources (22.3%, 45.9% and 34%, respectively). Moreover, E. coli (47.5%) and Klebsiella (0.4%) had, respectively, the highest and lowest distribution in all months considered. Based on the results, E.coli exists mostly in water resources; it is therefore of particular importance in the monitoring of water resources.

  11. Fecal Coliform Determinations. Training Module 5.115.3.77.

    ERIC Educational Resources Information Center

    Kirkwood Community Coll., Cedar Rapids, IA.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with multiple tube and membrane filter techniques for determining fecal coliform concentrations in a wastewater sample. Included are objectives, instructor guides, student handouts and transparency masters. This module considers proper…

  12. Antibiotic Resistance in an Indian Rural Community: A 'One-Health' Observational Study on Commensal Coliform from Humans, Animals, and Water.

    PubMed

    Purohit, Manju Raj; Chandran, Salesh; Shah, Harshada; Diwan, Vishal; Tamhankar, Ashok J; Stålsby Lundborg, Cecilia

    2017-04-06

    Antibiotic-resistant bacteria are an escalating grim menace to global public health. Our aim is to phenotype and genotype antibiotic-resistant commensal Escherichia coli (E. coli) from humans, animals, and water from the same community with a 'one-health' approach. The samples were collected from a village belonging to demographic surveillance site of Ruxmaniben Deepchand (R.D.) Gardi Medical College Ujjain, Central India. Commensal coliforms from stool samples from children aged 1-3 years and their environment (animals, drinking water from children's households, common source- and waste-water) were studied for antibiotic susceptibility and plasmid-encoded resistance genes. E. coli isolates from human ( n = 127), animal ( n = 21), waste- ( n = 12), source- ( n = 10), and household drinking water ( n = 122) carried 70%, 29%, 41%, 30%, and 30% multi-drug resistance, respectively. Extended spectrum beta-lactamase (ESBL) producers were 57% in human and 23% in environmental isolates. Co-resistance was frequent in penicillin, cephalosporin, and quinolone. Antibiotic-resistance genes bla CTX-M-9 and qnrS were most frequent. Group D-type isolates with resistance genes were mainly from humans and wastewater. Colistin resistance, or the mcr-1 gene, was not detected. The frequency of resistance, co-resistance, and resistant genes are high and similar in coliforms from humans and their environment. This emphasizes the need to mitigate antibiotic resistance with a 'one-health' approach.

  13. Effects of septic tank effluent on ground-water quality, Dade County, Florida: an interim report

    USGS Publications Warehouse

    Pitt, William A.

    1974-01-01

    Except at one site, no fecal coliforms were found below the 10-foot depth. Total coliforms exceeded a count of one colony per ml at the 60- foot depth at two sites. At one site a fecal streptococci count of 53 colonies per ml was found at the 60-foot depth and at another a count of seven colonies was found at the 40-foot depth. The three types of bacteria occur in higher concentration in the northern areas of the county than in the south. Bacteria concentrations were also higher where the septic tanks were more concentrated. 

  14. Preliminary survey of antibiotic-resistant fecal indicator bacteria and pathogenic Escherichia coli from river-water samples collected in Oakland County, Michigan, 2003

    USGS Publications Warehouse

    Fogarty, Lisa R.; Duris, Joseph W.; Aichele, Stephen S.

    2005-01-01

    A preliminary study was done in Oakland County, Michigan, to determine the concentration of fecal indicator bacteria (fecal coliform bacteria and enterococci), antibiotic resistance patterns of these two groups, and the presence of potentially pathogenic Escherichia coli (E. coli). For selected sites, specific members of these groups [E. coli, Enterococcus faecium (E. faecium) and Enterococcus faecalis (E. faecalis)] were isolated and tested for levels of resistance to specific antibiotics used to treat human infections by pathogens in these groups and for their potential to transfer these resistances. In addition, water samples from all sites were tested for indicators of potentially pathogenic E. coli by three assays: a growth-based assay for sorbitol-negative E. coli, an immunological assay for E. coli O157, and a molecular assay for three virulence and two serotype genes. Samples were also collected from two non-urbanized sites outside of Oakland County. Results from the urbanized Oakland County area were compared to those from these two non-urbanized sites. Fecal indicator bacteria concentrations exceeded State of Michigan recreational water-quality standards and (or) recommended U.S. Environmental Protection Agency (USEPA) standards in samples from all but two Oakland County sites. Multiple-antibiotic-resistant fecal coliform bacteria were found at all sites, including two reference sites from outside the county. Two sites (Stony Creek and Paint Creek) yielded fecal coliform isolates resistant to all tested antibiotics. Patterns indicative of extended-spectrum-β-lactamase (ESBL)- producing fecal coliform bacteria were found at eight sites in Oakland County and E. coli resistant to clinically significant antibiotics were recovered from the River Rouge, Clinton River, and Paint Creek. Vancomycin-resistant presumptive enterococci were found at six sites in Oakland County and were not found at the reference sites. Evidence of acquired antibiotic resistances was

  15. Bacteriological quality of ground water used for household supply, Lower Susquehanna River basin, Pennsylvania and Maryland

    USGS Publications Warehouse

    Bickford, Tammy M.; Lindsey, Bruce D.; Beaver, M.R.

    1996-01-01

    This report describes the bacteriological results of a ground-water study conducted from 1993 to 1995 as part of the U.S. Geological Survey's National Water-Quality Assessment Program in the Lower Susquehanna River Basin study unit. Water samples collected from 146 household supply wells were analyzed for fecal-indicator organisms including total coliform, fecal coliform, Escherichia coli (E. coli), and fecal streptococcus concentrations. Supporting data used in the interpretations are selected water-quality constituents, well-construction information, and the environmental setting at the well site including land use, physiography, and bedrock type. Water from nearly 70 percent of the wells sampled had total coliform present and thus was not suitable for drinking without treatment. Fecal coliforms were found in water from approximately 25 percent of the sampled wells. E. coli testing was not conducted in 1993. Approximately 30 percent of the 88 sampled wells had waters with E. coli. Fecal streptococcus bacteria was present in water from about 65 percent of the wells sampled. Bacteriological contamination was more likely to occur in water from wells in agricultural areas than in water from wells in forested areas. Water from wells sampled in the Ridge and Valley Physiographic Province was more likely to have bacteria than water from wells in the Piedmont Physiographic Province. Differences in bacterial concentrations among bedrock types are only statistically significant for E. coli. Bacterial concentrations are weakly related to well-age but not to other well characteristics such as the total well depth or the casing length. Relations exist between bacterial concentrations and selected water-quality constituents. Most wells from which water was sampled did not have sanitary seals and very few were grouted. This may have contributed to the number of detections of bacteria. It is uncertain whether the bacteria detected are the result of widespread aquifer

  16. Microbiological quality of ready-to-eat salads: an underestimated vehicle of bacteria and clinically relevant antibiotic resistance genes.

    PubMed

    Campos, Joana; Mourão, Joana; Pestana, Nazaré; Peixe, Luísa; Novais, Carla; Antunes, Patrícia

    2013-09-16

    The increase demand for fresh vegetables is causing an expansion of the market for minimally processed vegetables along with new recognized food safety problems. To gain further insight on this topic we analyzed the microbiological quality of Portuguese ready-to-eat salads (RTS) and their role in the spread of bacteria carrying acquired antibiotic resistance genes, food products scarcely considered in surveillance studies. A total of 50 RTS (7 brands; split or mixed leaves, carrot, corn) were collected in 5 national supermarket chains in Porto region (2010). They were tested for aerobic mesophilic counts, coliforms and Escherichia coli counts as well as for the presence of Salmonella and Listeria monocytogenes. Samples were also plated in different selective media with/without antibiotics before and after enrichment. The E. coli, other coliforms and Enterococcus recovered were characterized for antibiotic resistance profiles and clonality with phenotypic and genetic approaches. A high number of RTS presented poor microbiological quality (86%--aerobic mesophilic counts, 74%--coliforms, 4%--E. coli), despite the absence of screened pathogens. In addition, a high diversity of bacteria (species and clones) and antibiotic resistance backgrounds (phenotypes and genotypes) were observed, mostly with enrichment and antibiotic selective media. E. coli was detected in 13 samples (n=78; all types and 4 brands; phylogenetic groups A, B1 and D; none STEC) with resistance to tetracycline [72%; tet(A) and/or tet(B)], streptomycin (58%; aadA and/or strA-strB), sulfamethoxazole (50%; sul1 and/or sul2), trimethoprim (50%; dfrA1 or dfrA12), ampicillin (49%; blaTEM), nalidixic acid (36%), ciprofloxacin (5%) or chloramphenicol (3%; catA). E. coli clones, including the widespread group D/ST69, were detected in different samples from the same brand or different brands pointing out to a potential cross-contamination. Other clinically relevant resistance genes were detected in 2 Raoultella

  17. Sanitary evaluation of domestic water supply facilities with storage tanks and detection of Aeromonas, enteric and related bacteria in domestic water facilities in Okinawa Prefecture of Japan.

    PubMed

    Miyagi, Kazufumi; Sano, Kouichi; Hirai, Itaru

    2017-08-01

    To provide for temporary restrictions of the public water supply system, storage tanks are commonly installed in the domestic water systems of houses and apartment buildings in Okinawa Prefecture of Japan. To learn more about the sanitary condition and management of these water supply facilities with storage tanks (hereafter called "storage tank water systems") and the extent of bacterial contamination of water from these facilities, we investigated their usage and the existence of Aeromonas, enteric and related bacteria. Verbal interviews concerning the use and management of the storage tank water systems were carried out in each randomly sampled household. A total of 54 water samples were collected for bacteriological and physicochemical examinations. Conventional methods were used for total viable count, fecal coliforms, identification of bacteria such as Aeromonas, Enterobacteriaceae and non-fermentative Gram-negative rods (NF-GNR), and measurement of residual chlorine. On Aeromonas species, tests for putative virulence factor and an identification using 16S rRNA and rpoB genes were also performed. Water from the water storage systems was reported to be consumed directly without boiling in 22 of the 54 houses (40.7%). 31 of the sampled houses had installed water storage tanks of more than 1 cubic meter (m 3 ) per inhabitant, and in 21 of the sampled houses, the tank had never been cleaned. In all samples, the total viable count and fecal coliforms did not exceed quality levels prescribed by Japanese waterworks law. Although the quantity of bacteria detected was not high, 23 NF-GNR, 14 Enterobacteriaceae and 5 Aeromonas were isolated in 42.6%, 7.4% and 3.7% of samples respectively. One isolated A. hydrophila and four A. caviae possessed various putative virulence factors, especially A. hydrophila which had diverse putative pathogenic genes such as aer, hlyA, act, alt, ast, ser, and dam. Many bacteria were isolated when the concentration of residual chlorine

  18. Metal oxide/hydroxide-coated dual-media filter for simultaneous removal of bacteria and heavy metals from natural waters.

    PubMed

    Ahammed, M Mansoor; Meera, V

    2010-09-15

    The present study was conducted to compare the performance of a dual-media filter consisting of manganese oxide-coated (MOCS) and iron hydroxide-coated sand (IOCS) with that of IOCS filter and uncoated sand filter in treating water contaminated by microorganisms, heavy metals and turbidity with a view to its use in simple household water purification devices in developing countries. Long-duration column tests were conducted using two natural waters namely, roof-harvested rainwater and canal water. Performance of the filters showed that dual-media filter was more efficient in removing bacteria and heavy metals compared to IOCS filter, while uncoated sand filter showed very poor performance. The average effluent levels for dual-media filter when tested with rainwater were: turbidity 1.0+/-0.1 NTU; total coliforms 3+/-2 MPN/100 mL; heterotrophic plate count 170+/-20 CFU/mL; zinc 0.06+/-0.01 mg/L, while that for IOCS filter were: turbidity 1.0+/-0.1 NTU; total coliforms 4+/-2 MPN/100 mL; heterotrophic plate count 181+/-37 CFU/mL; zinc 0.20+/-0.07 mg/L. Similar results were obtained for canal water also. Up to 900 bed volumes (BV) could be treated without affecting the efficiency in the case of rainwater, while the filter operation had to be terminated after 500 BV due to excessive headloss in the case of canal water. The study thus showed the potential of the dual-media for use in low-cost household water filters for purification of natural waters. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Limnological Monitoring on the Upper Mississippi River System, 1993-1996: Lake City Field Station

    DTIC Science & Technology

    1999-10-01

    Reports of this type provide a synopsis of the collected data and collection methods, as well as a preliminary report of remarkable or unusual conditions ... conditions . To meet this need, Congress authorized a Long Term Resource Monitoring Program (LTRMP) for the Upper Mississippi River System (UMRS). The LTRMP...primarily for human consumption or regulatory purposes (e.g., chemical oxygen demand, biochemical oxygen demand, total coliform bacteria , fecal coliform

  20. Antibiotic Resistance in an Indian Rural Community: A ‘One-Health’ Observational Study on Commensal Coliform from Humans, Animals, and Water

    PubMed Central

    Purohit, Manju Raj; Chandran, Salesh; Shah, Harshada; Diwan, Vishal; Tamhankar, Ashok J.; Stålsby Lundborg, Cecilia

    2017-01-01

    Antibiotic-resistant bacteria are an escalating grim menace to global public health. Our aim is to phenotype and genotype antibiotic-resistant commensal Escherichia coli (E. coli) from humans, animals, and water from the same community with a ‘one-health’ approach. The samples were collected from a village belonging to demographic surveillance site of Ruxmaniben Deepchand (R.D.) Gardi Medical College Ujjain, Central India. Commensal coliforms from stool samples from children aged 1–3 years and their environment (animals, drinking water from children's households, common source- and waste-water) were studied for antibiotic susceptibility and plasmid-encoded resistance genes. E. coli isolates from human (n = 127), animal (n = 21), waste- (n = 12), source- (n = 10), and household drinking water (n = 122) carried 70%, 29%, 41%, 30%, and 30% multi-drug resistance, respectively. Extended spectrum beta-lactamase (ESBL) producers were 57% in human and 23% in environmental isolates. Co-resistance was frequent in penicillin, cephalosporin, and quinolone. Antibiotic-resistance genes blaCTX-M-9 and qnrS were most frequent. Group D-type isolates with resistance genes were mainly from humans and wastewater. Colistin resistance, or the mcr-1 gene, was not detected. The frequency of resistance, co-resistance, and resistant genes are high and similar in coliforms from humans and their environment. This emphasizes the need to mitigate antibiotic resistance with a ‘one-health’ approach. PMID:28383517

  1. Endotoxin, coliform, and dust levels in various types of rodent bedding.

    PubMed

    Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane

    2010-03-01

    Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating-tapping shaker. Paper bedding types contained significantly less endotoxin than did other bedding types; the highest levels of endotoxin were detected in hardwood and corncob beddings. The range of endotoxin content for each bedding type was: corncob bedding, 1913 to 4504 endotoxin units per gram (EU/g); hardwood bedding, 3121 to 5401 EU/g; corncob-paper mixed bedding, 1586 to 2416 EU/g; and paper bedding, less than 5 to 105 EU/g. Coliform counts varied from less than 10 to 7591 cfu/g in corncob beddings, 90 to 4010 cfu/g in corncob-paper mixed beddings, less than 10 to 137 cfu/g in hardwood beddings, and less than 10 cfu/g in paper beddings. Average dust content was less than 0.15% in all commercial bedding types. We conclude that paper bedding is the optimal bedding type for conducting LPS inhalation studies and that rodent bedding containing high levels of endotoxin may alter the results of respiratory and immunologic studies in rodents.

  2. Endotoxin, Coliform, and Dust Levels in Various Types of Rodent Bedding

    PubMed Central

    Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane B

    2010-01-01

    Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating–tapping shaker. Paper bedding types contained significantly less endotoxin than did other bedding types; the highest levels of endotoxin were detected in hardwood and corncob beddings. The range of endotoxin content for each bedding type was: corncob bedding, 1913 to 4504 endotoxin units per gram (EU/g); hardwood bedding, 3121 to 5401 EU/g; corncob–paper mixed bedding, 1586 to 2416 EU/g; and paper bedding, less than 5 to 105 EU/g. Coliform counts varied from less than 10 to 7591 cfu/g in corncob beddings, 90 to 4010 cfu/g in corncob–paper mixed beddings, less than 10 to 137 cfu/g in hardwood beddings, and less than 10 cfu/g in paper beddings. Average dust content was less than 0.15% in all commercial bedding types. We conclude that paper bedding is the optimal bedding type for conducting LPS inhalation studies and that rodent bedding containing high levels of endotoxin may alter the results of respiratory and immunologic studies in rodents. PMID:20353693

  3. Distribution of enteric bacteria in Antarctic seawater surrounding the Port-aux-Français permanent station (Kerguelen Island).

    PubMed

    Delille, D; Gleizon, F

    2003-09-01

    Untreated sewage has been released from Port-aux Français station, Kerguelen Island, into the Southern Ocean for more than 50 years. We investigated the spatial distribution of faecal bacteria indicators during a one-year survey conducted in seawater off Morbihan Bay near the French permanent station of the Kerguelen Island (49 degrees 21(')S, 70 degrees 30(')E). Seawater samples were taken bimonthly from nine stations evenly distributed around the sewage outfalls of the station. Escherichia coli and enterococci were estimated using specific microplates (Miniaturized method for the enumeration of E. coli or enterococci in surface and waste waters, "MU/EC or MU/SF methods", BIO-RAD( Copyright)). In order to evaluate the role of seasonal changes of environmental parameters on the survival of enteric bacteria, total and saprophytic bacterial abundances were also estimated in all seawater samples. High densities of faecal bacteria (maximum 10(4) cells 100 ml(-1)) were found in seawater surrounding the sewage outfall. However, enteric bacterial counts decreased rapidly with increasing distance from the outfall. In all samples collected further than 2 km from the outfall, the bacterial indicators were absent or present in small numbers (<10 cells 100 ml(-1)). Faecal coliforms were not detected in samples collected at pristine sites located 10 km from Port-aux-Français. Despite these low contamination levels, faecal bacteria were always detected in the vicinity of the sewage outfall during the seasonal survey. The concentration of faecal bacteria may be related to the number of people inhabiting the station.

  4. Preliminary evaluation of pathogenic bacteria loading on organic Municipal Solid Waste compost and vermicompost.

    PubMed

    Soobhany, Nuhaa

    2018-01-15

    The use of composts or vermicomposts derived from organic fraction of Municipal Solid Waste (OFMSW) brought about certain disagreement in terms of high level of bacterial pathogens, thereby surpassing the legal restrictions. This preliminary study was undertaken to compare the evolution of pathogenic bacteria on OFMSW compost against vermicompost (generated by Eudrilus eugeniae) with promises of achieving sanitation goals. Analysis to quality data showed that OFMSW vermicomposting caused a moderately higher reduction in total coliforms in contrast to composting. E. coli in OFMSW composts was found to be in the range of 4.72-4.96 log 10  CFU g -1 whilst on a clear contrary, E. coli was undetectable in the final vermicomposts (6.01-6.14 logs of reduction) which might be explained by the involvement of the digestive processes in worms' guts. Both OFMSW composts and vermicomposts generated Salmonella-free products which were acceptable for agricultural usage and soil improvement. In comparison to compost, the analysis of this research indicated that earthworm activity can effectively destroy bacterial pathogenic load in OFMSW vermicomposts. But still, this study necessitates extra research in order to comprehend the factors that direct pathogenic bacteria in vermicomposting and earthworm-free decomposition systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Controls on the quality of harvested rainwater in residential systems

    NASA Astrophysics Data System (ADS)

    Sojka, S. L.; Phung, D.; Hollingsworth, C.

    2014-12-01

    Rainwater harvesting systems, in which runoff from roofs is collected and used for irrigation, toilets and other purposes, present a viable solution to limited freshwater supplies and excess stormwater runoff. However, a lack of data on the quality of harvested rainwater hinders adoption of rainwater harvesting systems and makes development of rainwater harvesting regulations difficult. We conducted monthly surveys of 6 existing residential rainwater harvesting systems ranging in age from 1 to 11 years measuring pH, temperature, dissolved oxygen, total suspended solids, dissolved organic carbon, and coliform bacteria. We also examined a subset of the samples for iron, lead, mercury and arsenic. Many of the systems routinely met the water quality requirements for non-potable use without additional treatment, which is often required by regulations. In addition, while previous studies have shown that roof runoff contains heavy metals, the water in all systems showed very low or undetectable levels of metal contamination. Coliform bacteria concentration ranged from 20 to greater than 1400 CFU's per 100 mL and correlated with total suspended solids, which ranged from 2 - 7 mg l-1. The relationship between suspended solids and bacteria population was confirmed in a controlled experiment on the impact of filtering the rainwater before storage. Filtration decreased total suspended solids and total coliforms and increased dissolved oxygen concentration. This project provides insight into the effects of system design and a baseline assessment of the quality of harvested rainwater in existing systems.

  6. Effects on water quality due to flood-water detention by Barker and Addicks Reservoirs, Houston, Texas

    USGS Publications Warehouse

    Liscum, Fred; Goss, R.L.; Paul, E.M.

    1987-01-01

    The third approach was a comparison at each site of the mean, maximum, and minimum values computed for seven constituents that did not correlate with discharge. These constituents or properties of water were temperature, pH, dissolved oxygen, dissolved oxygen percent saturation, total-coliform bacteria, fecal-conform bacteria, and fecal-streptococci bacteria. The only consistent water-quality changes observed were with the three bacteria groups, which were decreased by flood-water detention.

  7. Membrane filtration media for the enumeration of coliform organisms and Escherichia coli in water: comparison of Tergitol 7 and lauryl sulphate with Teepol 610.

    PubMed Central

    1980-01-01

    In a multi-laboratory trial with the membrane filtration technique, three surfactants--Teepol 610 (T610), Tergitol 7 (T7) and sodium lauryl sulphate (LS)--were compared in media for the enumeration of coliform organisms and Escherichia coli in water. A total of 179 samples of water (87 raw and 92 marginally chlorinated) were examined for colony counts of coliform organisms, and 185 water samples (94 raw and 91 marginally chlorinated) for E. coli. Slight differences in the confirmed colony counts between the three media were noted, but few of these were observed consistently in every laboratory. In most laboratories, T7 gave slightly higher counts of E. coli than LS with chlorinated waters; a higher incidence of false-positive results for E. coli at 44 degrees C was also noted with T7. As there were no outstanding differences in the trial, sodium lauryl sulphate, which is chemically defined, cheap and readily available, is therefore recommended for use at a concentration of 0 . 1% instead of Teepol 610 in the standard medium for the enumeration of coliform organisms and E. coli in water by the membrane filtration technique. PMID:7005324

  8. Spatial distribution of total, ammonia-oxidizing, and denitrifying bacteria in biological wastewater treatment reactors for bioregenerative life support

    NASA Technical Reports Server (NTRS)

    Sakano, Yuko; Pickering, Karen D.; Strom, Peter F.; Kerkhof, Lee J.; Janes, H. W. (Principal Investigator)

    2002-01-01

    Bioregenerative life support systems may be necessary for long-term space missions due to the high cost of lifting supplies and equipment into orbit. In this study, we investigated two biological wastewater treatment reactors designed to recover potable water for a spacefaring crew being tested at Johnson Space Center. The experiment (Lunar-Mars Life Support Test Project-Phase III) consisted of four crew members confined in a test chamber for 91 days. In order to recycle all water during the experiment, an immobilized cell bioreactor (ICB) was employed for organic carbon removal and a trickling filter bioreactor (TFB) was utilized for ammonia removal, followed by physical-chemical treatment. In this study, the spatial distribution of various microorganisms within each bioreactor was analyzed by using biofilm samples taken from four locations in the ICB and three locations in the TFB. Three target genes were used for characterization of bacteria: the 16S rRNA gene for the total bacterial community, the ammonia monooxygenase (amoA) gene for ammonia-oxidizing bacteria, and the nitrous oxide reductase (nosZ) gene for denitrifying bacteria. A combination of terminal restriction fragment length polymorphism (T-RFLP), sequence, and phylogenetic analyses indicated that the microbial community composition in the ICB and the TFB consisted mainly of Proteobacteria, low-G+C gram-positive bacteria, and a Cytophaga-Flexibacter-Bacteroides group. Fifty-seven novel 16S rRNA genes, 8 novel amoA genes, and 12 new nosZ genes were identified in this study. Temporal shifts in the species composition of total bacteria in both the ICB and the TFB and ammonia-oxidizing and denitrifying bacteria in the TFB were also detected when the biofilms were compared with the inocula after 91 days. This result suggests that specific microbial populations were either brought in by the crew or enriched in the reactors during the course of operation.

  9. Bacteria and Nutrients in the Obhur Recreational Sharm, Jeddah, Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Turki, Adnan; Mudarris, Mohammed

    2013-04-01

    Environmental pollution that render waters along the recreational shore unsatisfactory for use by the general public has become a global health problem. This study was carried out to examine the marine waters in sampling stations located at Sharm Obhur (North of Jeddah). These parameters included: total coliform (TC), l fecal coliform (FC) and nutrients (NO2-N, NO3-N, NH4-N and PO4-P). A comparison of the mean values of nutrients in Sharm Obhur with those of other locations in the Red Sea suggests that the mean levels of nutrients were similar to those of unpolluted areas. TC and FC counts were higher at the north sampling stations than the south ones, and with little variations between their numbers. FC was not recovered at stations to the south. The study shows that TC and FC counts at all sampling stations similar to the levels reported for normal unpolluted sea water. Keywords: Pollution, Nutrients, Coliforms, Sharm Obhur, Red Sea.

  10. Escherichia coli hyperepidemic clone ST410-A harboring blaCTX-M-15 isolated from fresh vegetables in a municipal market in Quito-Ecuador.

    PubMed

    Ortega-Paredes, David; Barba, Pedro; Mena-López, Santiago; Espinel, Nathaly; Zurita, Jeannete

    2018-04-30

    Dissemination of Extended spectrum β-lactamases (ESBL) Enterobacteriaceae is a major medical threat. Vegetables and fruits, which are usually consumed raw, are a very suitable pathway for the spread of these bacteria from farm-to-fork. However, limited information exists regarding resistant bacteria and epidemic clones that are disseminated in vegetables and tap water in South America. We processed a total of 90 samples in triplicate of nine typically consumed raw vegetables from a central municipal market, and tap water samples were processed from twenty-one locations in Quito, Ecuador. The samples were analyzed for total coliforms and ESBL Enterobacteriaceae contamination using the dilution filtration method. ESBL Escherichia coli isolates were phenotypically and genotypically characterized. The water was free of Enterobacteriaceae, but all the vegetables and fruits (except for blackberries) presented total coliform counts. Watercress had the highest load of total coliforms (3.3 × 10E4). ESBL E. coli was detected in alfalfa, leaf lettuce and parsley/cilantro samples. Alfalfa had the highest load of ESBL E. coli/total coliforms (1/3.3 × 10E2). We identified E. coli ST44-A and ST410-A harboring bla CTX-M-15 downstream of ISEcp1. Alfalfa and parsley/cilantro were contaminated with hyperepidemic E. coli ST410-A, which was resistant to quinolones and harbored bla CTX-M-15 . For the first time, we report ESBL E. coli ST410-A from vegetables and express an alert regarding the health risk this could represent. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Agar Underlay Method for Recovery of Sublethally Heat-Injured Bacteria

    PubMed Central

    Kang, D. H.; Siragusa, G. R.

    1999-01-01

    A method of recovering sublethally heat-injured bacteria was developed. The procedure (termed the agar underlay method) uses a nonselective agar underlaid with a selective medium. In a two-chambered petri dish, the Lutri plate (LP), a nonselective agar is inoculated with a population of sublethally heat-injured bacteria. After a 2-h repair incubation period, selective agar is added to the bottom chamber of the LP and incubated. By diffusing through the nonselective top agar, selective agents from the underlay medium impart selectivity to the system. By the agar underlay method, recovery rates of the heat-injured food-borne pathogens Escherichia coli O157:H7 and Salmonella typhimurium were not different (P > 0.05) from recovery rates determined with nonselective media. Sublethally heat-injured cells (60°C for 1.5 min in buffer or 80°C for 30 s on meat surfaces) grew and produced a typical colony morphology and color reaction when the agar underlay procedure was used with the appropriate respective selective agars. Unlike agar overlay methods for injury repair, the agar underlay procedure allows the typical selective-medium colony morphology to develop and allows colonies to be more easily picked for further characterization. Higher recovery rates of heat-injured fecal enterococci from bovine fecal samples and total coliforms from animal waste lagoons were obtained by the agar underlay method with selective agars than by direct plating on the respective selective media. PMID:10583985

  12. Bacteria and Bioactivity in Holder Pasteurized and Shelf-Stable Human Milk Products

    PubMed Central

    2017-01-01

    Abstract Background: Historically, Holder pasteurization has been used to pasteurize donor human milk available in a hospital setting. There is extensive research that provides an overview of the impact of Holder pasteurization on bioactive components of human milk. A shelf-stable (SS) human milk product, created using retort processing, recently became available; however, to our knowledge, little has been published about the effect of retort processing on human milk. Objective: We aimed to assess the ability of retort processing to eliminate bacteria and to quantify the difference in lysozyme and secretory immunoglobulin A (sIgA) activity between Holder pasteurized (HP) and SS human milk. Methods: Milk samples from 60 mothers were pooled. From this pool, 36 samples were taken: 12 samples were kept raw, 12 samples were HP, and 12 samples were retort processed to create an SS product. All samples were analyzed for total aerobic bacteria, coliform bacteria, Bacillus cereus, sIgA activity, and lysozyme activity. Raw samples served as the control. Results: One raw sample and 3 HP samples contained B. cereus at the time of culture. There were no detectable bacteria in SS samples at the time of culture. Raw samples had significantly greater lysozyme and sIgA activity than HP and SS samples (P < 0.0001). HP samples retained significantly more lysozyme and sIgA activity (54% and 87%, respectively) than SS samples (0% and 11%, respectively). Conclusions: Human milk processed using Holder pasteurization should continue to be screened for the presence of B. cereus. Clinicians should be aware of the differences in the retention of lysozyme and sIgA activity in HP and SS products when making feeding decisions for medically fragile or immunocompromised infants to ensure that patients are receiving the maximum immune protection. PMID:29955718

  13. Influence of seasonal environmental variables on the distribution of presumptive fecal Coliforms around an Antarctic research station.

    PubMed

    Hughes, Kevin A

    2003-08-01

    Factors affecting fecal microorganism survival and distribution in the Antarctic marine environment include solar radiation, water salinity, temperature, sea ice conditions, and fecal input by humans and local wildlife populations. This study assessed the influence of these factors on the distribution of presumptive fecal coliforms around Rothera Point, Adelaide Island, Antarctic Peninsula during the austral summer and winter of February 1999 to September 1999. Each factor had a different degree of influence depending on the time of year. In summer (February), although the station population was high, presumptive fecal coliform concentrations were low, probably due to the biologically damaging effects of solar radiation. However, summer algal blooms reduced penetration of solar radiation into the water column. By early winter (April), fecal coliform concentrations were high, due to increased fecal input by migrant wildlife, while solar radiation doses were low. By late winter (September), fecal coliform concentrations were high near the station sewage outfall, as sea ice formation limited solar radiation penetration into the sea and prevented wind-driven water circulation near the outfall. During this study, environmental factors masked the effect of station population numbers on sewage plume size. If sewage production increases throughout the Antarctic, environmental factors may become less significant and effective sewage waste management will become increasingly important. These findings highlight the need for year-round monitoring of fecal coliform distribution in Antarctic waters near research stations to produce realistic evaluations of sewage pollution persistence and dispersal.

  14. Bacteria, viruses, and parasites in an intermittent stream protected from and exposed to pasturing cattle: prevalence, densities, and quantitative microbial risk assessment.

    PubMed

    Wilkes, G; Brassard, J; Edge, T A; Gannon, V; Jokinen, C C; Jones, T H; Neumann, N; Pintar, K D M; Ruecker, N; Schmidt, P J; Sunohara, M; Topp, E; Lapen, D R

    2013-10-15

    Over 3500 individual water samples, for 131 sampling times, targeting waterborne pathogens/fecal indicator bacteria were collected during a 7-year period from 4 sites along an intermittent stream running through a small livestock pasture system with and without cattle access-to-stream restriction measures. The study assessed the impact of cattle pasturing/riparian zone protection on: pathogen (bacterial, viral, parasite) occurrence, concentrations of fecal indicators, and quantitative microbial risk assessments (QMRA) of the risk of Cryptosporidium, Giardia and Escherichia coli O157:H7 infection in humans. Methodologies were developed to compute QMRA mean risks on the basis of water samples exhibiting potentially human infectious Cryptosporidium and E. coli based on genotyping Crytosporidium, and E. coli O157:H7 presence/absence information paired with enumerated E. coli. All Giardia spp. were considered infectious. No significant pasturing treatment effects were observed among pathogens, with the exception of Campylobacter spp. and E. coli O157:H7. Campylobacter spp. prevalence significantly decreased downstream through pasture treatments and E. coli O157:H7 was observed in a few instances in the middle of the unrestricted pasture. Densities of total coliform, fecal coliform, and E. coli reduced significantly downstream in the restricted pasture system, but not in the unrestricted system. Seasonal and flow conditions were associated with greater indicator bacteria densities, especially in the summer. Norovirus GII was detected at rates of 7-22% of samples for all monitoring sites, and rotavirus in 0-7% of samples for all monitoring sites; pasture treatment trends were not evident, however. Seasonal and stream flow variables (and their interactions) were relatively more important than pasture treatments for initially stratifying pathogen occurrence and higher fecal indicator bacteria densities. Significant positive associations among fecal indicator bacteria and

  15. The Effectiveness of Sanitary Inspections as a Risk Assessment Tool for Thermotolerant Coliform Bacteria Contamination of Rural Drinking Water: A Review of Data from West Bengal, India

    PubMed Central

    Snoad, Christian; Nagel, Corey; Bhattacharya, Animesh; Thomas, Evan

    2017-01-01

    The use of sanitary inspections combined with periodic water quality testing has been recommended in some cases as screening tools for fecal contamination. We conducted sanitary inspections and tested for thermotolerant coliforms (TTCs), a fecal indicator bacteria, among 7,317 unique water sources in West Bengal, India. Our results indicate that the sanitary inspection score has poor ability to identify TTC-contaminated sources. Among deep and shallow hand pumps, the area under curve (AUC) for prediction of TTC > 0 was 0.58 (95% confidence interval [CI] = 0.53–0.61) and 0.58 (95% CI = 0.54–0.62), respectively, indicating that the sanitary inspection score was only marginally better than chance in discriminating between contaminated and uncontaminated sources of this type. A slightly higher AUC value of 0.64 (95% CI=0.57–0.71) was observed when the sanitary inspection score was used for prediction of TTC > 0 among the gravity-fed piped sources. Among unprotected springs (AUC = 0.48, 95% CI = 0.38–0.55) and unprotected dug wells (AUC = 0.41, 95% CI = 0.20–0.66), the sanitary inspection score performed more poorly than chance in discriminating between sites with TTC < 1 and TTC > 0. Aggregating over all source types, the sensitivity (true positive rate) of a high/very high sanitary inspection score for TTC contamination (TTC > 1 CFU/100 mL) was 29.4% and the specificity (true negative rate) was 77.9%, resulting in substantial misclassification of the sites when using the established risk categories. These findings suggest that sanitary surveys are inappropriate screening tools for identifying TTC contamination at water points. PMID:28115676

  16. The Effectiveness of Sanitary Inspections as a Risk Assessment Tool for Thermotolerant Coliform Bacteria Contamination of Rural Drinking Water: A Review of Data from West Bengal, India.

    PubMed

    Snoad, Christian; Nagel, Corey; Bhattacharya, Animesh; Thomas, Evan

    2017-04-01

    AbstractThe use of sanitary inspections combined with periodic water quality testing has been recommended in some cases as screening tools for fecal contamination. We conducted sanitary inspections and tested for thermotolerant coliforms (TTCs), a fecal indicator bacteria, among 7,317 unique water sources in West Bengal, India. Our results indicate that the sanitary inspection score has poor ability to identify TTC-contaminated sources. Among deep and shallow hand pumps, the area under curve (AUC) for prediction of TTC > 0 was 0.58 (95% confidence interval [CI] = 0.53-0.61) and 0.58 (95% CI = 0.54-0.62), respectively, indicating that the sanitary inspection score was only marginally better than chance in discriminating between contaminated and uncontaminated sources of this type. A slightly higher AUC value of 0.64 (95% CI=0.57-0.71) was observed when the sanitary inspection score was used for prediction of TTC > 0 among the gravity-fed piped sources. Among unprotected springs (AUC = 0.48, 95% CI = 0.38-0.55) and unprotected dug wells (AUC = 0.41, 95% CI = 0.20-0.66), the sanitary inspection score performed more poorly than chance in discriminating between sites with TTC < 1 and TTC > 0. Aggregating over all source types, the sensitivity (true positive rate) of a high/very high sanitary inspection score for TTC contamination (TTC > 1 CFU/100 mL) was 29.4% and the specificity (true negative rate) was 77.9%, resulting in substantial misclassification of the sites when using the established risk categories. These findings suggest that sanitary surveys are inappropriate screening tools for identifying TTC contamination at water points.

  17. Comparison of E. coli, enterococci, and fecal coliform as indicators for brackish water quality assessment.

    PubMed

    Jin, Guang; Jeng, Huei-Wang; Bradford, Henry; Englande, A J

    2004-01-01

    Escherichia coli (E. coli), enterococci, and fecal coliform data were collected and compared as potential indicators for swimmablility assessment of a brackish waterbody (Lake Pontchartrain, Louisiana). These indicators were measured during lake background conditions, in stormwater runoff (before dilution with lake water), and in the outfall plume within the lake following storm events. Microbial indicator titers associated with suspended particles and lake-bottom sediments were also investigated. Overall reduction rate constants for fecal coliform, E. coli, and enterococci in lake water and sediment were measured and reported. Attachment of microbial indicators to suspended matter and subsequent sedimentation appeared to be a significant fate mechanism. A slower reduction rate of indicator organisms in sediment further suggested that bottom sediment may act as a reservoir for prolonging indicator organism survival and added concern of recontamination of overlaying waters due to potential solids resuspension. Results indicated that enterococci might be a more stable indicator than E. coli and fecal coliform and, consequently, a more conservative indicator under brackish water conditions.

  18. Use of total of Escherichia coli counts to assess the hygienic characteristics of a beef carcass dressing process.

    PubMed

    Gill, C O; McGinnis, J C; Badoni, M

    1996-08-01

    Swab samples were obtained from 3 sites on the surfaces of beef carcasses passing through a high speed dressing process, with 24 samples from each site being obtained at each of 4 points in the process. The aerobic microflora recovered from each swab after incubation at 25 degrees C was enumerated and characterized, and numbers of coliforms and Escherichia coli were determined. The data on aerobic flora indicated that skinning results in similar contamination of all 3 sites, that further deposition of bacteria at the brisket site occurs after skinning, and that trimming and washing achieve modest decontamination of the neck and brisket site, and extensive decontamination of the rump site. Changes in flora compositions during processing were too limited to much affect the assessment based on the aerobic flora total counts alone. The E. coli data indicated that during skinning the rump site was more heavily contaminated with faecal organisms than the other sites, that contamination of the brisket site is little altered between skinning and carcass splitting, although there is an extensive redistribution of E. coli at the neck site and sporadic, limited decontamination of the rump site, and that trimming and washing do not decontaminate the neck or rump sites, but that the rump site is extensively decontaminated by trimming. There was good correlation between E. coli and coliform counts, but weak correlation between E. coli and aerobic, 25 degrees C, counts. The findings suggest that assessments of beef carcass dressing processes for Hazard Analysis: Critical Control Point (HACCP) purposes should be based on enumerations of E. coli, or perhaps coliforms, rather than of the aerobic flora, to avoid important misunderstandings of the hygienic effects of the various operations in a process.

  19. Probabilistic assessment of compliance with the numerical criteria for fecal coliforms in rivers

    NASA Astrophysics Data System (ADS)

    Cha, YoonKyung

    2017-04-01

    Most guidelines for assessing fecal contamination in surface waters suggest that a waterbody is impaired if a certain percent or the geometric mean of samples exceeds the numerical criteria for fecal indicator organisms. However, this raw score approach is not able to account for the uncertainty and variability in the sample statistics. In a Bayesian hierarchical modeling approach, the uncertainty in the mean parameter is expressed as a posterior distribution, and the probability of not violating the criterion is referred to as the confidence of compliance (COC). Further, the spatiotemporal variability in the mean parameter can be quantified by imposing the hierarchical structure on the model. The monitoring data spanning 91 sites across the four major rivers (the Han, Geum, Yeongsan, and Nakdong) of South Korea for the years 2007-2016 were used. The Bayesian hierarchical model was developed for each river to predict the COC with the criteria for fecal coliforms. The established criteria for fecal coliforms are less than 10, 100, 200, and 1,000 CFU/100mL in the river whose water quality goal corresponds to Class Ia, Ib, II, and III, respectively. The model results suggested that the COC varied significantly by site, ranging from 0.0 to 98.9 percent across the four rivers. In the Geum, Yeongsan, and Nakdong Rivers, COC values in the upper river sections were substantially lower than those in the upper river sections. The model suggested that for all four rivers the spatial component, compared with annual and seasonal components, made the largest contribution to the variability in mean fecal coliforms. In all four rivers, mean levels for fecal coliform during the summer (July to September) were distinctly higher than those during other seasons. A decreasing pattern was clearly shown in the Yeongsan River over the recent decade, while monotonic increases or decreases were not shown in other three rivers.

  20. Bacteriological quality of drinking water in the Atebubu-Amantin District of the Brong-Ahafo Region of Ghana

    NASA Astrophysics Data System (ADS)

    Tekpor, M.; Akrong, M. O.; Asmah, M. H.; Banu, R. A.; Ansa, E. D. O.

    2017-09-01

    The study was carried out to determine the bacteriological safety of water in hand-dug wells in the Atebubu-Amantin District of the Brong-Ahafo Region in Ghana. A total of 60 samples were collected from ten hand dug wells and analysed for total coliform (TC), faecal coliform (FC), E. coli (EC), Salmonella spp. (SP) and Enterococcus spp. (ES). Data was collected in both the rainy and the dry seasons. The results obtained showed that water from all the wells in the study area did not meet the World Health Organisation guideline and Ghana standard for drinking water of zero (0) coliform forming unit (cfu) per 100 ml for TC, FC, EC, SP and ES, respectively. Contamination was found to be high in the wells during the wet season as compared to the dry season. Wells (A1 to A5) which were close to septic tanks had high bacteria counts in both seasons. The total coliform counts ranged from 2.98 to 5.93 log cfu/100 ml in the wet season and 3.10-5.03 log cfu/100 ml in the dry season. There was drastic reduction of faecal coliform count from a range of 2.78-4.55 log cfu/100 ml in the wet season to 1.70-3.51 log cfu/100 ml in the dry season. The high bacteria count in wells A1 to A5 could be attributed to the closeness of the wells to the septic tank, and contaminant transport through the saturated underground zones. It is recommended that the water should be treated properly before drinking.

  1. Marine Bacteria Cause False-Positive Results in the Colilert-18 Rapid Identification Test for Escherichia coli in Florida Waters

    PubMed Central

    Pisciotta, John M.; Rath, Damon F.; Stanek, Paul A.; Flanery, D. Michael; Harwood, Valerie J.

    2002-01-01

    The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the “positive” wells inoculated with marine samples. Ortho-nitrophenyl-β-d-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-β-d-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml−1 inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml−1 in seawater diluted 1:10 with freshwater to ≈5,000 CFU ml−1 in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU·100 ml−1, while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU·100 ml−1. The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by

  2. Effects of hydrologic, biological, and environmental processes on sources and concentrations of fecal bacteria in the Cuyahoga River, with implications for management of recreational waters in Summit and Cuyahoga Counties, Ohio

    USGS Publications Warehouse

    Myers, Donna N.; Koltun, G.F.; Francy, Donna S.

    1998-01-01

    Discharges of fecal bacteria (fecal coliform bacteria and Escherichia coli ) to the middle main stem of the Cuyahoga River from storm water, combined sewers, and incompletely disinfected wastewater have resulted in frequent exceedances of bacteriological water-quality standards in a 23-mile reach of the river that flows through the Cuyahoga Valley National Recreation Area. Contamination of the middle main stem of the Cuyahoga River by bacteria of fecal origin and subsequent transport to downstream areas where water-contact recreation is an important use of the river are a concern because of the potential public-health risk from the presence of enteric pathogens. Independent field investigations of bacterial decay, dilution, dispersion, transport, and sources, and bacterial contamination of streambed sediments, were completed in 1991-93 during periods of rainfall and runoff. The highest concentration of fecal coliform bacteria observed in the middle main stem during three transport studies exceeded the single-sample fecal coliform standard applicable to primary-contact recreation by a factor of approximately 1,300 and exceeded the Escherichia coli standard by a factor of approximately 8,000. The geometric-mean concentrations of fecal bacteria in the middle main stem were 6.7 to 12.3 times higher than geometric-mean concentrations in the monitored tributaries, and 1.8 to 7.0 times larger than the geometric-mean concentrations discharged from the Akron Water Pollution Control Station. Decay rates of fecal bacteria measured in field studies in 1992 ranged from 0.0018 per hour to 0.0372 per hour for fecal coliform bacteria and from 0.0022 per hour to 0.0407 per hour for Escherichia coli. Most of the decay rates measured in June and August were significantly higher than decay rates measured in April and October. Results of field studies demonstrated that concentrations of fecal coliform bacteria were 1.2 to 58 times higher in streambed sediments than in the overlying

  3. A novel quantitative reverse-transcription PCR (qRT-PCR) for the enumeration of total bacteria, using meat micro-flora as a model.

    PubMed

    Dolan, Anthony; Burgess, Catherine M; Barry, Thomas B; Fanning, Seamus; Duffy, Geraldine

    2009-04-01

    A sensitive quantitative reverse-transcription PCR (qRT-PCR) method was developed for enumeration of total bacteria. Using two sets of primers separately to target the ribonuclease-P (RNase P) RNA transcripts of gram positive and gram negative bacteria. Standard curves were generated using SYBR Green I kits for the LightCycler 2.0 instrument (Roche Diagnostics) to allow quantification of mixed microflora in liquid media. RNA standards were used and extracted from known cell equivalents and subsequently converted to cDNA for the construction of standard curves. The number of mixed bacteria in culture was determined by qRT-PCR, and the results correlated (r(2)=0.88, rsd=0.466) with the total viable count over the range from approx. Log(10) 3 to approx. Log(10) 7 CFU ml(-1). The rapid nature of this assay (8 h) and its potential as an alternative method to the standard plate count method to predict total viable counts and shelf life are discussed.

  4. Survival and enumeration of the fecal indicators Bifidobacterium adolescentis and Escherichia coli in a tropical rain forest watershed.

    PubMed Central

    Carrillo, M; Estrada, E; Hazen, T C

    1985-01-01

    The density of Bifidobacterium spp., fecal coliforms, Escherichia coli, and total anaerobic bacteria, acridine orange direct counts, percentages of total bacterial community activity and respiration, and 12 physical and chemical parameters were measured simultaneously at six sites for 12 months in the Mameyes River rain forest watershed, Puerto Rico. The densities of all bacteria were higher than those reported for uncontaminated temperate rivers, even though other water quality parameters would indicate that all uncontaminated sites were oligotrophic. The highest densities for all indicator bacteria were at the site receiving sewage effluent; however, the highest elevation site in the watershed had the next highest densities. Correlations between bacterial densities, nitrates, temperature, phosphates, and total phosphorus indicated that all viable counts were related to nutrient levels, regardless of the site sampled. In situ diffusion chamber studies at two different sites indicated that E. coli could survive, remain physiologically active, and regrow at rates that were dependent on nutrient levels of the ambient waters. Bifidobacterium adolescentis did not survive at either site but did show different rates of decline and physiological activity at the two sites. Bifidobacteria show promise as a better indicator of recent fecal contamination in tropical freshwaters than E. coli or fecal coliforms; however, the YN-6 medium did not prove to be effective for enumeration of bifidobacteria. The coliform maximum contaminant levels for assessing water usability for drinking and recreation appear to be unworkable in tropical freshwaters. PMID:3901921

  5. UV inactivation of pathogenic and indicator microorganisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, J.C.; Ossoff, S.F.; Lobe, D.C.

    1985-06-01

    Survival was measured as a function of the dose of germicidal UV light for the bacteria Escherichia coli, Salmonella typhi, Shigella sonnei, Streptococcus faecalis, Staphylococcus aureus, and Bacillus subtilis spores, the enteric viruses poliovirus type 1 and simian rotavirus SA11, the cysts of the protozoan Acanthamoeba castellanii, as well as for total coliforms and standard plate count microorganisms from secondary effluent. The doses of UV light necessary for a 99.9% inactivation of the cultured vegetative bacteria, total coliforms, and standard plate count microorganisms were comparable. However, the viruses, the bacterial spores, and the amoebic cysts required about 3 to 4more » times, 9 times, and 15 times, respectively, the dose required for E. coli. These ratios covered a narrower relative dose range than that previously reported for chlorine disinfection of E. coli, viruses, spores, and cysts.« less

  6. A Systematic Review and Meta-Analysis of Fecal Contamination and Inadequate Treatment of Packaged Water.

    PubMed

    Williams, Ashley R; Bain, Robert E S; Fisher, Michael B; Cronk, Ryan; Kelly, Emma R; Bartram, Jamie

    2015-01-01

    Packaged water products provide an increasingly important source of water for consumption. However, recent studies raise concerns over their safety. To assess the microbial safety of packaged water, examine differences between regions, country incomes, packaged water types, and compare packaged water with other water sources. We performed a systematic review and meta-analysis. Articles published in English, French, Portuguese, Spanish and Turkish, with no date restrictions were identified from online databases and two previous reviews. Studies published before April 2014 that assessed packaged water for the presence of Escherichia coli, thermotolerant or total coliforms were included provided they tested at least ten samples or brands. A total of 170 studies were included in the review. The majority of studies did not detect fecal indicator bacteria in packaged water (78/141). Compared to packaged water from upper-middle and high-income countries, packaged water from low and lower-middle-income countries was 4.6 (95% CI: 2.6-8.1) and 13.6 (95% CI: 6.9-26.7) times more likely to contain fecal indicator bacteria and total coliforms, respectively. Compared to all other packaged water types, water from small bottles was less likely to be contaminated with fecal indicator bacteria (OR = 0.32, 95%CI: 0.17-0.58) and total coliforms (OR = 0.10, 95%CI: 0.05, 0.22). Packaged water was less likely to contain fecal indicator bacteria (OR = 0.35, 95%CI: 0.20, 0.62) compared to other water sources used for consumption. Policymakers and regulators should recognize the potential benefits of packaged water in providing safer water for consumption at and away from home, especially for those who are otherwise unlikely to gain access to a reliable, safe water supply in the near future. To improve the quality of packaged water products they should be integrated into regulatory and monitoring frameworks.

  7. Climate relationships to fecal bacterial densities in Maryland shellfish harvest waters.

    PubMed

    Leight, A K; Hood, R; Wood, R; Brohawn, K

    2016-02-01

    Coastal states of the United States (US) routinely monitor shellfish harvest waters for types of bacteria that indicate the potential presence of fecal pollution. The densities of these indicator bacteria in natural waters may be related to climate in several ways, including through runoff from precipitation and survival related to water temperatures. The relationship between interannual precipitation and air temperature patterns and the densities of fecal indicator bacteria in shellfish harvest waters in Maryland's portion of the Chesapeake Bay was quantified using 34 years of data (1979-2013). Annual and seasonal precipitation totals had a strong positive relationship with average fecal coliform levels (R(2) = 0.69) and the proportion of samples with bacterial densities above the FDA regulatory criteria (R(2) = 0.77). Fecal coliform levels were also significantly and negatively related to average annual air temperature (R(2) = -0.43) and the average air temperature of the warmest month (R(2) = -0.57), while average seasonal air temperature was only significantly related to fecal coliform levels in the summer. River and regional fecal coliform levels displayed a wide range of relationships with precipitation and air temperature patterns, with stronger relationships in rural areas and mainstem Bay stations. Fecal coliform levels tended to be higher in years when the bulk of precipitation occurred throughout the summer and/or fall (August to September). Fecal coliform levels often peaked in late fall and winter, with precipitation peaking in summer and early fall. Continental-scale sea level pressure (SLP) analysis revealed an association between atmospheric patterns that influence both extratropical and tropical storm tracks and very high fecal coliform years, while regional precipitation was found to be significantly correlated with the Atlantic Multidecadal Oscillation and the Pacific North American Pattern. These findings indicate that management of

  8. Effects of dietary supplementation with antimicrobial peptide-P5 on growth performance, apparent total tract digestibility, faecal and intestinal microflora and intestinal morphology of weanling pigs.

    PubMed

    Yoon, Jung Ho; Ingale, Santosh Laxman; Kim, Jin Soo; Kim, Kwang Hyun; Lohakare, Jayant; Park, Yoon Kyung; Park, Jun Cheol; Kwon, Ill Kyong; Chae, Byung Jo

    2013-02-01

    The increase in drug-resistant bacteria and the ban on antibiotic growth promoters worldwide make the search for novel means of preventing bacterial infection and promoting growth performance imperative. In this sense, antimicrobial peptides are thought to be ideal candidates owing to their antimicrobial properties, broad spectrum of activity and low propensity for development of bacterial resistance. The aim of the present study was to investigate the effect of dietary supplementation with antimicrobial peptide-P5 (AMP-P5) on weanling pig nutrition. A total of 240 weanling pigs were allotted to four treatments on the basis of initial body weight. There were four replicates in each treatment, with 15 pigs per replicate. Dietary treatments were negative control (NC, basal diet without antimicrobial), positive control (PC, basal diet + 1.5 g kg(-1) apramycin), basal diet with 40 mg kg(-1) AMP-P5 (P5-40) and basal diet with 60 mg kg(-1) AMP-P5 (P5-60). Pigs fed the PC or P5-60 diet showed improved (P < 0.05) overall growth performance, apparent total tract digestibility of dry matter, crude protein and gross energy and reduced (P < 0.05) faecal and intestinal coliforms compared with pigs fed the NC diet. The results obtained in this study indicate that dietary supplementation with 60 mg kg(-1) AMP-P5 has the potential to improve the growth performance and apparent total tract digestibility of nutrients and reduce coliforms in weanling pigs. Copyright © 2012 Society of Chemical Industry.

  9. Groundwater quality in the Chemung River, Eastern Lake Ontario, and Lower Hudson River Basins, New York, 2013

    USGS Publications Warehouse

    Scott, Tia-Marie; Nystrom, Elizabeth A.; Reddy, James E.

    2015-11-10

    The Lower Hudson River Basin study area covers 5,607 square miles and encompasses the part of the Lower Hudson River Basin that lies within New York plus the parts of the Housatonic, Hackensack, Bronx, and Saugatuck River Basins that are in New York. Twelve of the wells sampled in the Lower Hudson River Basin are completed in sand-and-gravel deposits, and 13 are completed in bedrock. Groundwater in the Lower Hudson River Basin was generally of good quality, although properties and concentrations of some constituents—pH, sodium, chloride, dissolved solids, arsenic, aluminum, iron, manganese, radon-222, total coliform bacteria, fecal coliform bacteria, Escherichia coli bacteria, and heterotrophic plate count—equaled or exceeded primary, secondary, or proposed drinking-water standards. The constituent most frequently detected in concentrations exceeding drinking-water standards (20 of 25 samples) was radon-222.

  10. Microbiological baseline study of beef and pork carcasses from provincially inspected abattoirs in Alberta, Canada

    PubMed Central

    Bohaychuk, Valerie M.; Gensler, Gary E.; Barrios, Pablo Romero

    2011-01-01

    In 2006 and 2007 beef and pork carcass swabs from provincially inspected abattoirs in Alberta, Canada were tested to determine the levels of total aerobic bacteria, coliform bacteria, and generic Escherichia coli, and the prevalence of Salmonella spp., Campylobacter spp., and Shiga toxin-producing E. coli (STEC). Swabs from beef and pork carcasses from 48 and 34 facilities, respectively, were analyzed. All samples tested were positive for aerobic bacteria with 99.8% of beef and 96.0% of pork samples, having total counts of ≤ 100 000 CFU/cm2. Coliform bacteria were isolated from 22.4% and 42.0% of beef and pork carcass samples, respectively. Generic E. coli were recovered from 14.6% of beef and 33.7% of pork carcass samples. For beef carcasses, positive tests were obtained for 0.1% of 1036 samples tested for Salmonella spp., 1.5% of 1022 samples tested for Campylobacter spp. and 5.4% of 1018 samples tested for STEC. For pork carcasses, positive tests were obtained for 1.6 % of 1076 samples tested for Salmonella spp., 8.8% of 1070 samples tested for Campylobacter spp. and 4.8% of 1067 samples tested for STEC. PMID:22467964

  11. Effects of cattle manure on erosion rates and runoff water pollution by faecal coliforms.

    PubMed

    Ramos, M C; Quinton, J N; Tyrrel, S F

    2006-01-01

    The large quantities of slurry and manure that are produced annually in many areas in which cattle are raised could be an important source of organic matter and nutrients for agriculture. However, the benefits of waste recycling may be partially offset by the risk of water pollution associated with runoff from the fields to which slurry or manure has been applied. In this paper, the effects of cattle manure application on soil erosion rates and runoff and on surface water pollution by faecal coliforms are analysed. Rainfall simulations at a rate of 70 mm h(-1) were conducted in a sandy loam soil packed into soil flumes (2.5m long x 1m wide) at a bulk density of 1400 kg m(-3), with and without cattle slurry manure applied on the surface. For each simulation, sediment and runoff rates were analysed and in those simulations with applied slurry, presumptive faecal coliform (PFC) concentrations in the runoff were evaluated. The application of slurry on the soil surface appeared to have a protective effect on the soils, reducing soil detachment by up to 70% but increasing runoff volume by up to 30%. This practice implies an important source of pollution for surface waters especially if rainfall takes place within a short period after application. The concentrations of micro-organisms (presumptive faecal coliforms (PFCs)) found in water runoff ranged from 1.9 x 10(4) to 1.1 x 10(6) PFC 100mL(-1), depending on the initial concentration in the slurry, and they were particularly high during the first phases of the rainfall event. The result indicates a strong relationship between the faecal coliforms transported by runoff and the organic matter in the sediment.

  12. 33 CFR 159.53 - General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...

  13. 33 CFR 159.53 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...

  14. 33 CFR 159.53 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...

  15. 33 CFR 159.53 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...

  16. 33 CFR 159.53 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating... having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not...

  17. Natural attenuation in a surface water channel and a coastal aquifer by monitoring presence and removal of indicator bacteria, pathogens and antibiotic resistance gene: model development

    NASA Astrophysics Data System (ADS)

    Masciopinto, Costantino; Visino, Fabrizio; Luprano, Maria Laura; Levantesi, Caterina; Tandoi, Valter

    2015-04-01

    The spreading of microbial contamination into the environment, represents a very relevant problem, which leads to an increasing health concern. For this reason, it is important to identify and characterize the extent of natural depuration in water environmental particularly for reducing the presence of faecal contamination indicator bacteria, pathogens and antibiotic resistance genes (ARG). In this study, the presence of the above reported microbial parameters was analyzed in a surface water channel and in a coastal aquifer in southern Italy (Ostuni) southern Italy, both affected by Ostuni municipal treatment plant effluents and by local run-off. Several samples were collected from surface water, flowing in channels, and from wells in our study area. In particular, the water samples were analyzed to detect 7 fecal contamination indicators (E. coli, total coliforms, Clostridium p. spores, somatic coliphages, Enterococci and heterotrophic bacteria), Salmonella spp and the presence of ARGs. The water samples were also tested for chemical constituents. Finally a mathematical model has been developed in order to simulate pathogen migration pathways in the fractured groundwater and corresponding possible mitigation of pathogens in pumping wells.

  18. Microbiological Safety of Kitchen Sponges Used in Food Establishments

    PubMed Central

    Bacha, Ketema

    2016-01-01

    Kitchen sponges are among the possible sources of contaminants in food establishments. The main purpose of the current study was, therefore, to assess the microbiological safety of sponges as it has been used in selected food establishments of Jimma town. Accordingly, the microbiological safety of a total of 201 kitchen sponges randomly collected from food establishments was evaluated against the total counts of aerobic mesophilic bacteria (AMB), Enterobacteriaceae, coliforms, and yeast and molds. The mean counts of aerobic mesophilic bacteria ranged from 7.43 to 12.44 log CFU/mm3. The isolated genera were dominated by Pseudomonas (16.9%), Bacillus (11.1%), Micrococcus (10.6%), Streptococcus (7.8%), and Lactobacillus (6%) excluding the unidentified Gram positive rods (4.9%) and Gram negative rods (9.9%). The high microbial counts (aerobic mesophilic bacteria, coliforms, Enterobacteriaceae, and yeast and molds) reveal the existence of poor kitchen sponge sanitization practice. Awareness creation training on basic hygienic practices to food handlers and periodic change of kitchen sponges are recommended. PMID:27840819

  19. Capability of the two microorganisms Bifidobacterium breve B632 and Bifidobacterium breve BR03 to colonize the intestinal microbiota of children.

    PubMed

    Mogna, Luca; Del Piano, Mario; Mogna, Giovanni

    2014-01-01

    The total number of bacteria present in the gut microbiota of a newborn is consistently lower than the average found in adults, with the extent of this difference being directly related to body weight and age. It could be assumed that a lower number of viable probiotic cells is necessary to achieve significant gut colonization in infants and children. This study assessed the capability of Bifidobacterium breve B632 (DSM 24706) and Bifidobacterium breve BR03 (DSM 16604), 2 strains able to significantly inhibit some gram-negative bacteria in vitro, to integrate into the intestinal microbiota of children. Ten healthy children aged an average of 5.7±2.6 were given an oily suspension containing B. breve B632 and B. breve BR03 for 21 consecutive days. The daily dose was 100 million live cells of each strain. Fecal specimens were collected and analyzed at the beginning (d0) and at the end of the study (d21). Total fecal bifidobacteria and coliforms have been quantified by microbiological plate counts. A significant increase in total fecal bifidobacteria (from 8.99 to 9.47 log10 CFU/g, P=0.042) and a parallel decrease in total coliforms (from 8.60 to 7.93 log10 CFU/g, P=0.048) was recorded after 21 days of supplementation. An oily suspension has proved an effective way of providing probiotics to children. A lower viable cells concentration was sufficient to mediate this effect in the light of the fact that the intestinal microbiota of children harbors a considerably smaller amount of total bacteria compared with adults. In addition to gut colonization in healthy children, B. breve B632 and B. breve BR03 were able to decrease total fecal coliforms, therefore supporting their potential specific use in colicky infants.

  20. Assessment of possible sources of microbiological contamination in the water column and streambed sediment of the Jacks Fork, Ozark National Scenic Riverways, Missouri - Phase III

    USGS Publications Warehouse

    Davis, Jerri V.; Barr, Miya N.

    2006-01-01

    In 1998, a 5 river-mile reach of the Jacks Fork was included on Missouri's list of impaired waters as required by Section 303(d) of the Federal Clean Water Act. The identified pollutant on the Jacks Fork was fecal coliform bacteria. The length of the impaired reach was changed to 7 miles on the Missouri 2002 303(d) list because of data indicating the fecal coliform bacteria problem existed over a broader area. The U.S. Geological Survey, in cooperation with the National Park Service, conducted a study to better understand the extent and sources of microbiological contamination within the Jacks Fork from Alley Spring to the mouth, which includes the 7-mile 303(d) reach. Ten sites were sampled from June 2003 through October 2003 and from June 2004 through October 2004. Water-column and streambed sediment samples were collected from main-stem and tributary sites mostly during base-flow conditions during a variety of recreational season river uses and analyzed for fecal coliform and Escherichia coli bacteria. Isolates of Escherichia coli obtained from water samples collected at five sites were submitted for rep-PCR analysis to identify presumptive sources of fecal indicator bacteria in the Jacks Fork. Results indicate that recreational users (including boaters and swimmers) are not the primary source of fecal coliform bacteria in the Jacks Fork; rather, the presence of fecal coliform bacteria is associated with other animals, of which horses are the primary source. Increases in fecal coliform bacteria densities in the Jacks Fork are associated with cross-country horseback trail-riding events.

  1. Effect of fecal contamination and cross-contamination on numbers of coliform, Escherichia coli, Campylobacter, and Salmonella on immersion-chilled broiler carcasses.

    PubMed

    Smith, D P; Cason, J A; Berrang, M E

    2005-07-01

    The effect of prechill fecal contamination on numbers of bacteria on immersion-chilled carcasses was tested in each of three replicate trials. For each trial, 16 eviscerated broiler carcasses were split into 32 halves and assigned to one of two groups. Cecal contents (0.1 g inoculated with Campylobacter and nalidixic acid-resistant Salmonella) were applied to each of eight halves in one group (direct contamination) that were placed into one paddle chiller (contaminated), whereas the other paired halves were placed into another chiller (control). From the second group of eight split birds, one of each paired half was placed in the contaminated chiller (to determine cross-contamination) and the other half was placed in the control chiller. Postchill carcass halves were sampled by a 1-min rinse in sterile water, which was collected and cultured. Bacterial counts were reported as log CFU per milliliter of rinsate. There were no significant statistical differences (paired t test, P < 0.05) from direct contamination for coliforms (mean 3.0 log CFU) and Escherichia coli (mean 2.7 log CFU), although Campylobacter numbers significantly increased from control values because of direct contamination (1.5 versus 2.1 log CFU), and the incidence increased from 79 to 100%. There was no significant effect of cross-contamination on coliform (mean 2.9 log CFU) or E. coli (mean 2.6 log CFU) numbers. Nevertheless, Campylobacter levels were significantly higher after exposure to cross-contamination (1.6 versus 2.0 log CFU), and the incidence of this bacterium increased from 75 to 100%. Salmonella-positive halves increased from 0 to 42% postchill because of direct contamination and from 0 to 25% as a result of cross-contamination after chilling. Water samples and surface swabs taken postchill from the contaminated chiller were higher for Campylobacter than those taken from the control chiller. Immersion chilling equilibrated bacterial numbers between contaminated and control halves

  2. Productive performance of weanling piglets was improved by administration of a mixture of bacteriophages, targeted to control Coliforms and Clostridium spp. shedding in a challenging environment.

    PubMed

    Hosseindoust, A R; Lee, S H; Kim, J S; Choi, Y H; Kwon, I K; Chae, B J

    2017-10-01

    This study was conducted to investigate the effects of bacteriophages in different environments on growth performance, digestibility, ileal and caecal microbiota, gut morphology and immunity of weanling pigs. Two hundred piglets were randomly assigned to four treatment groups with five replicate pens with 10 pigs per pen. A 2 × 2 factorial arrangement of treatments was used to investigate the response of weanling pigs to supplemental bacteriophages (0 and 1.0 g/kg of diet) in contaminated or hygienic environments. Bacteriophages supplementation did not affect average daily gain (ADG), average daily feed intake (ADFI) and gain:feed in phases I and III; however, there was a significant improvement in ADG and gain:feed in phase II. The supplementation of bacteriophages increased the overall gain:feed of pigs. The overall result showed a greater ADG and ADFI in hygienic room. There were reductions in population of both ileal (p < 0.05) and caecal (p < 0.01) Clostridium spp. and ileal coliforms (p < 0.01) with the inclusion of bacteriophages in the diet. Bacteriophages increased ileal Lactobacillus and caecal Bifidobacterium and tended to increase ileal Bifidobacterium (p = 0.08). Contaminated environment decreased ileal Lactobacillus and caecal Bifidobacterium and tended to increase ileal Clostridium (p = 0.08) and coliforms (p = 0.08). Total anaerobic bacteria was tended to decrease (p = 0.06) in contaminated environment. Jejunal villus height increased in pigs received bacteriophages, but they did not affect other morphological items. The interaction between bacteriophages and environment tended to be significant (p = 0.06) for ileal villus height and ileal villus height to crypt depth ratio. The overall faecal score was significantly greater in hygienic environment and bacteriophages groups. The present findings indicate that there is an interactive effect on feed efficiency between bacteriophages and contaminated environment. In addition

  3. Water quality indicators: bacteria, coliphages, enteric viruses.

    PubMed

    Lin, Johnson; Ganesh, Atheesha

    2013-12-01

    Water quality through the presence of pathogenic enteric microorganisms may affect human health. Coliform bacteria, Escherichia coli and coliphages are normally used as indicators of water quality. However, the presence of above-mentioned indicators do not always suggest the presence of human enteric viruses. It is important to study human enteric viruses in water. Human enteric viruses can tolerate fluctuating environmental conditions and survive in the environment for long periods of time becoming causal agents of diarrhoeal diseases. Therefore, the potential of human pathogenic viruses as significant indicators of water quality is emerging. Human Adenoviruses and other viruses have been proposed as suitable indices for the effective identification of such organisms of human origin contaminating water systems. This article reports on the recent developments in the management of water quality specifically focusing on human enteric viruses as indicators.

  4. Effects of effluent spray irrigation on ground water at a test site near Tarpon Springs, Florida

    USGS Publications Warehouse

    Brown, D.P.

    1982-01-01

    Secondary-treated effluent was applied to a 7.2-acre test site near Tarpon Springs, Fla., for about 1 year at an average rate of 0.06 million gallons per day and 3 years at 0.11 million gallons per day. Chemical fertilizer was applied periodically to the test site and adjacent areas. Periodic mounding of the water table occurred due to effluent irrigation, inducing radial flow from the test site. Physical, geochemical, biochemical processes effectively reduced total nitrogen concentration 90% and total phosphorous concentration more than 95% in the ground water of the surficial aquifer about 300 feet downgradient from the test site from that of the applied effluent. Downgradient, total nitrogen averaged 2.4 milligrams per liter and total phosphorus averaged 0.17 milligrams per liter. Substantial increases in total phosphorus were observed when the pH of the ground water increased. Total coliform bacteria in the ground water of the surficial aquifer were generally less than 100 colonies per 100 milliliters. Fecal coliform bacteria were generally less than 25 colonies per 100 milliliters at the test site and were not detected downgradient or near the test site. Fecal streptococcal bacteria were generally less than 100 colonies per 100 milliliters at the test site, but were detected on three occasions near the test site. (USGS)

  5. Development of total maximum daily loads for bacteria impaired watershed using the comprehensive hydrology and water quality simulation model.

    PubMed

    Kim, Sang M; Brannan, Kevin M; Zeckoski, Rebecca W; Benham, Brian L

    2014-01-01

    The objective of this study was to develop bacteria total maximum daily loads (TMDLs) for the Hardware River watershed in the Commonwealth of Virginia, USA. The TMDL program is an integrated watershed management approach required by the Clean Water Act. The TMDLs were developed to meet Virginia's water quality standard for bacteria at the time, which stated that the calendar-month geometric mean concentration of Escherichia coli should not exceed 126 cfu/100 mL, and that no single sample should exceed a concentration of 235 cfu/100 mL. The bacteria impairment TMDLs were developed using the Hydrological Simulation Program-FORTRAN (HSPF). The hydrology and water quality components of HSPF were calibrated and validated using data from the Hardware River watershed to ensure that the model adequately simulated runoff and bacteria concentrations. The calibrated and validated HSPF model was used to estimate the contributions from the various bacteria sources in the Hardware River watershed to the in-stream concentration. Bacteria loads were estimated through an extensive source characterization process. Simulation results for existing conditions indicated that the majority of the bacteria came from livestock and wildlife direct deposits and pervious lands. Different source reduction scenarios were evaluated to identify scenarios that meet both the geometric mean and single sample maximum E. coli criteria with zero violations. The resulting scenarios required extreme and impractical reductions from livestock and wildlife sources. Results from studies similar to this across Virginia partially contributed to a reconsideration of the standard's applicability to TMDL development.

  6. Rainfall intensity effects on removal of fecal indicator bacteria from solid dairy manure applied over grass-covered soil.

    PubMed

    Blaustein, Ryan A; Hill, Robert L; Micallef, Shirley A; Shelton, Daniel R; Pachepsky, Yakov A

    2016-01-01

    The rainfall-induced release of pathogens and microbial indicators from land-applied manure and their subsequent removal with runoff and infiltration precedes the impairment of surface and groundwater resources. It has been assumed that rainfall intensity and changes in intensity during rainfall do not affect microbial removal when expressed as a function of rainfall depth. The objective of this work was to test this assumption by measuring the removal of Escherichia coli, enterococci, total coliforms, and chloride ion from dairy manure applied in soil boxes containing fescue, under 3, 6, and 9cmh(-1) of rainfall. Runoff and leachate were collected at increasing time intervals during rainfall, and post-rainfall soil samples were taken at 0, 2, 5, and 10cm depths. Three kinetic-based models were fitted to the data on manure-constituent removal with runoff. Rainfall intensity appeared to have positive effects on rainwater partitioning to runoff, and removal with this effluent type occurred in two stages. While rainfall intensity generally did not impact the parameters of runoff-removal models, it had significant, inverse effects on the numbers of bacteria remaining in soil after rainfall. As rainfall intensity and soil profile depth increased, the numbers of indicator bacteria tended to decrease. The cumulative removal of E. coli from manure exceeded that of enterococci, especially in the form of removal with infiltration. This work may be used to improve the parameterization of models for bacteria removal with runoff and to advance estimations of depths of bacteria removal with infiltration, both of which are critical to risk assessment of microbial fate and transport in the environment. Published by Elsevier B.V.

  7. Effectiveness of Active Packaging on Control of Escherichia Coli O157:H7 and Total Aerobic Bacteria on Iceberg Lettuce.

    PubMed

    Lu, Haixia; Zhu, Junli; Li, Jianrong; Chen, Jinru

    2015-06-01

    Contaminated leafy green vegetables have been linked to several outbreaks of human gastrointestinal infections. Antimicrobial interventions that are adoptable by the fresh produce industry for control of pathogen contamination are in great demand. This study was undertaken to evaluate the efficacy of sustained active packaging on control of Escherichia coli O157:H7 and total aerobic bacteria on lettuce. Commercial Iceberg lettuce was inoculated with a 3-strain mixture of E. coli O157:H7 at 10(2) or 10(4) CFU/g. The contaminated lettuce and un-inoculated controls were placed respectively in 5 different active packaging structures. Traditional, nonactive packaging structure was included as controls. Packaged lettuce was stored at 4, 10, or 22 °C for 3 wk and sampled weekly for the population of E. coli O157:H7 and total aerobic bacteria. Results showed that packaging structures with ClO2 generator, CO2 generator, or one of the O2 scavengers effectively controlled the growth of E. coli O157:H7 and total aerobic bacteria under all storage conditions. Packaging structure with the ClO2 generator was most effective and no E. coli O157:H7 was detected in samples packaged in this structure except for those that were inoculated with 4 log CFU/g of E. coli O157:H7 and stored at 22 °C. Packaging structures with an oxygen scavenger and the allyl isothiocyanate generator were mostly ineffective in control of the growth of the bacteria on Iceberg lettuce. The research suggests that some of the packaging structures evaluated in the study can be used to control the presence of foodborne pathogens on leafy green vegetables. © 2015 Institute of Food Technologists®

  8. Micro-zooplankton grazing as a means of fecal bacteria removal in stormwater BMPs.

    PubMed

    Burtchett, Jade M; Mallin, Michael A; Cahoon, Lawrence B

    2017-06-01

    A priority for environmental managers is control of stormwater runoff pollution, especially fecal microbial pollution. This research was designed to determine if fecal bacterial grazing by micro-zooplankton is a significant control on fecal bacteria in aquatic best management practices (BMPs); if grazing differs between a wet detention pond and a constructed wetland; and if environmental factors enhance grazing. Both 3-day grazing tests and 24-h dilution assays were used to determine grazing differences between the two types of BMP. Micro-zooplankton grazing was a stronger bacteria removal mechanism in stormwater wetlands rich in aquatic vegetation compared to a standard wet detention pond, although grazing was important in detention ponds as well. Our experiments indicated that the majority of grazers that fed on fecal bacteria were <20 μm in size. Grazing rates were positively correlated with fecal coliform abundance and increased water temperatures. Enumeration of grazers demonstrated that protozoans were significantly more abundant among wetland vegetation than in open water, and open wetland waters contained more flagellates and dinoflagellates than open wet detention pond waters. Grazing on fecal bacteria in BMPs is enhanced by aquatic vegetation, and grazing in aquatic BMPs in warmer climates should be greater than in cooler climates.

  9. The effect of dietary garlic supplementation on body weight gain, feed intake, feed conversion efficiency, faecal score, faecal coliform count and feeding cost in crossbred dairy calves.

    PubMed

    Ghosh, Sudipta; Mehla, Ram K; Sirohi, S K; Roy, Biswajit

    2010-06-01

    Thirty-six crossbred calves (Holstein cross) of 5 days of age were used to study the effect of garlic extract feeding on their performance up to the age of 2 months (pre-ruminant stage). They were randomly allotted into treatment and control groups (18 numbers in each group). Performance was evaluated by measuring average body weight (BW) gain, feed intake (dry matter (DM), total digestible nutrient (TDN) and crude protein (CP)), feed conversion efficiency (FCE; DM, TDN and CP), faecal score, faecal coliform count and feeding cost. Diets were the same for the both groups. In addition, treatment group received garlic extract supplementation at 250 mg/kg BW per day per calf. Body weight measured weekly, feed intake measured twice daily, proximate analysis of feeds and fodders analysed weekly, faecal scores monitored daily and faecal coliform count done weekly. There was significant increase in average body weight gain, feed intake and FCE and significant decrease in severity of scours as measured by faecal score and faecal coliform count in the treatment group compared to the control group (P < 0.01). Feed cost per kilogramme BW gain was significantly lower in the treatment group compared to control group (P < 0.01). The results suggest that garlic extract can be supplemented to the calves for better performance.

  10. Diversity of fecal coliforms and their antimicrobial resistance patterns in wastewater treatment model plant.

    PubMed

    Luczkiewicz, A; Fudala-Ksiazek, S; Jankowska, K; Quant, B; Olańczuk-Neyman, K

    2010-01-01

    The occurrence of resistance patterns among wastewater fecal coliforms was determined in the study. Susceptibility of the isolates was tested against 19 antimicrobial agents: aminoglycosides, aztreonam, carbapenems, cephalosporines, beta-lactam/beta-lactamase inhibitors, penicillines, tetracycline, trimethoprim/sulfamethoxazole, and fluoroquinolones. Additionally the removal of resistant isolates was evaluated in the laboratory-scale wastewater treatment model plant (M-WWTP), continuously supplied with the wastewater obtained from the full-scale WWTP. Number of fecal coliforms in raw (after mechanical treatment) and treated wastewater, as well as in aerobic chamber effluent was determined using selective medium. The selected strains were identified and examined for antibiotic resistance using Phoenix Automated Microbiology System (BD Biosciences, USA). The strains were identified as Escherichia coli (n=222), Klebsiella pneumoniae ssp. ozaenae (n=9), and Pantoea agglomerans (n=1). The isolate of P. agglomerans as well as 48% of E. coli isolates were sensitive to all antimicrobials tested. The most frequent resistance patterns were found for ampicillin: 100% of K. pneumoniae ssp. ozaenae and 41% of E. coli isolates. Among E. coli isolates 12% was regarded as multiple antimicrobial resistant (MAR). In the studied M-WWTP, the applied activated sludge processes reduced considerably the number of fecal coliforms, but increased the ratio of antimicrobial-resistant E. coli isolates to sensitive ones, especially among strains with MAR patterns.

  11. Enterobacteria identification and detection of diarrheagenic Escherichia coli in a Port Complex

    PubMed Central

    Costa, Clarissa Frota Macatrão; Neto, Valério Monteiro; Santos, Bruno Rafael de Carvalho; Costa, Bruno Rafael Rabelo; Azevedo, Alexandre; Serra, Josilene Lima; Mendes, Hermínio Benítez Rabello; Nascimento, Adenilde Ribeiro; Mendes, Mariana Bonfim Pinto; Kuppinger, Oliver

    2014-01-01

    The Port Complex of Maranhão (PCM) is the second largest port complex in Brazil, receiving ships with large volumes of ballast water. To evaluate the microbiological quality of its waters, physicochemical parameters (pH and salinity), the number of coliforms (thermotolerants and totals), and the presence of enterobacterias and diarrheagenic Escherichia coli strains were analyzed. In order to identify the presence of E. coli virulence genes target regions of the stx, elt, est, aggR, CVD432, ipaH and eae nucleotide sequences were studied. The presence of totals and thermotolerants coliforms were positive. Analyzing the salinity parameter, a significant increase in total coliforms was observed during the rainy season. We identified the species Escherichia coli, Proteus mirabilis, Citrobacter freundii, Proteus vulgaris, Klebsiella pneumoniae, Klebsiella ozaenae, Morganella morganii, Enterobacter cloacae and Edwardsiella tarda. Out of the 51 E. coli isolated, two were positive for the elt gene and one was positive for the CVD432 sequence, features of enterotoxigenic and enteroaggregative strains, respectively. This study reveals that the PCM is contaminated by enterobacteria and diarrheagenic E.coli thus providing evidence regarding the risk of these bacteria being carried by ships to other countries, and draws attention to the input of fecal bacteria brought by ships in the port waters of Maranhão. PMID:25477930

  12. Microbial quality of some vegetables sold in ED DueimTwon, Sudan.

    PubMed

    Goja, Arafat Mohammed; Mahmoud, Mohamed Salih Osman

    2013-06-15

    This study was probably the first research carried out to investigate the microbiological quality of some vegetables sold in ED DueimTwon, Sudan. Four species of vegetables were used, Arugula (Eruca sativa), Mloukhia (Corchorus olitorius), Tomato (Lycopersicon esculentum) and Green pepper (Capsicum annuum). The samples were collected and examined according to standardized methods for total viable bacteria, coliforms and fecal coliform count. The average of total viable count ranged from 1.2 x 105-5.6 x 105 CFU mL(-1) for Arugula; 2.1 x 105-2.8 x 107 CFU mL(-1) for Mloukhia; 3.4 x 105-4.8 x 105 for Tomato and 2.3 x 105-8.0 x 106 CFU mL(-1) for Green pepper. However, the maximum level of total and fecal coliform were (93, 21); (28, 11); (75, 15) and (150, 20) MPN 100 mL(-1), respectively. Twelve bacteria belonging to five genera were isolated. Staphylococcus (33%) was the most predominant isolated followed by Enterobacteriaceae (25%), Bacillus (17%) and Streptococcus (17%). Micrococcus (8%) was the least dominant isolated. The results of microbial counts of these vegetable samples in this study indicate that, the agricultural practices, harvesting, hygiene, transporting and selling points are poor and therefore, the higher microbial load could be risked for public health.

  13. Occurrence of Toxic Cyanobacterial Blooms in Rio de la Plata Estuary, Argentina: Field Study and Data Analysis

    PubMed Central

    Giannuzzi, L.; Carvajal, G.; Corradini, M. G.; Araujo Andrade, C.; Echenique, R.; Andrinolo, D.

    2012-01-01

    Water samples were collected during 3 years (2004–2007) at three sampling sites in the Rio de la Plata estuary. Thirteen biological, physical, and chemical parameters were determined on the water samples. The presence of microcystin-LR in the reservoir samples, and also in domestic water samples, was confirmed and quantified. Microcystin-LR concentration ranged between 0.02 and 8.6 μg.L−1. Principal components analysis was used to identify the factors promoting cyanobacteria growth. The proliferation of cyanobacteria was accompanied by the presence of high total and fecal coliforms bacteria (>1500 MNP/100 mL), temperature ≥25°C, and total phosphorus content ≥1.24 mg·L−1. The observed fluctuating patterns of Microcystis aeruginosa, total coliforms, and Microcystin-LR were also described by probabilistic models based on the log-normal and extreme value distributions. The sampling sites were compared in terms of the distribution parameters and the probability of observing high concentrations for Microcystis aeruginosa, total coliforms, and microcystin-LR concentration. PMID:22523486

  14. Use of DNA Markers for Investigating Sources of Bacteria in Contaminated Ground Water: Wooster Township, Wayne County, Ohio

    USGS Publications Warehouse

    Dumouchelle, Denise H.

    2006-01-01

    In 2004, a public-health nuisance was declared by the Wayne County Board of Health in the Scenic Heights Drive-Batdorf Road area of Wooster Township, Wayne County, Ohio, because of concerns about the safety of water from local wells. Repeated sampling had detected the presence of fecal-indicator bacteria and elevated nitrate concentrations. In June 2006, the U.S. Geological Survey (USGS), in cooperation with the Ohio Environmental Protection Agency (Ohio EPA), collected and analyzed samples from some of the affected wells to help investigate the possibility of human-origin bacterial contamination. Water samples from 12 wells and 5 home sewage-treatment systems (HSTS) were collected. Bromide concentrations were determined in samples from the 12 wells. Samples from 5 of the 12 wells were analyzed for wastewater compounds. Total coliform, enterococci and Escherichia coli (E. coli) bacteria concentrations were determined for samples from 8 of the 12 wells. In addition, two microbial source-tracking tools that employ DNA markers were used on samples from several wells and a composite sample of water from five septic tanks. The DNA markers from the Enterococcus faecium species and the order Bacteroidales are associated with specific sources, either human or ruminant sources. Bromide concentrations ranged from 0.04 to 0.18 milligrams per liter (mg/L). No wastewater compounds were detected at concentrations above the reporting limits. Samples from the 12 wells also were collected by Ohio EPA and analyzed for chloride and nitrate. Chloride concentrations ranged from 12.6 to 61.6 mg/L and nitrate concentrations ranged from 2.34 to 11.9 mg/L (as N). Total coliforms and enterococci were detected in samples from 8 wells, at concentrations from 2 to 200 colony-forming units per 100 milliliters (CFU/100 mL) and 0.5 to 17 CFU/100 mL, respectively. E. coli were detected in samples from three of the eight wells, at concentrations of 1 or 2 CFU/100 mL. Tests for the human

  15. Radionuclides, inorganic constitutents, organic compounds, and bacteria in water from selected wells and springs from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman Area, Idaho, 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartholomay, R.C.; Edwards, D.D.; Campbell, L.J.

    1994-11-01

    The U.S. Geological Survey and the Idaho Department of Water Resources, in response to a request from the U.S. Department of Energy, sampled 18 sites as part of a long-term project to monitor water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering Laboratory to the Hagerman area. Water samples were collected and analyzed for selected radionuclides, inorganic constituents, organic compounds, and bacteria. The samples were collected from 13 irrigation wells, 1 domestic well, 1 spring, 2 stock wells, and 1 public supply well. Quality assurance samples also were collected and analyzed. Nonemore » of the samples analyzed for radionuclides, inorganic constituents, or organic compounds exceeded the established maximum contaminant levels for drinking water. Most of the radionuclide and inorganic constituent concentrations exceeded their respective reporting levels. Most of the samples analyzed for surfactants and dissolved organic carbon had concentrations that exceeded their reporting levels. None of the samples contained reportable concentrations of purgeable organic compounds or pesticides. Total coliform bacteria was present in nine samples.« less

  16. Water quality and diversity of yeasts from tropical lakes and rivers from the Rio Doce basin in Southeastern Brazil

    PubMed Central

    Medeiros, Adriana O.; Missagia, Beatriz S.; Brandão, Luciana R.; Callisto, Marcos; Barbosa, Francisco A. R.; Rosa, Carlos A.

    2012-01-01

    Yeast communities were assessed in 14 rivers and four lakes from the Doce River basin in Brazil, during the rainy and dry seasons of the years 2000 and 2001. Water samples were collected at the subsurface in all sites. The following physical and chemical parameters were measured: temperature, dissolved oxygen, pH, electrical conductivity, total phosphorus, ortho-phosphate, ammonium, nitrate, nitrite and total nitrogen and the counts of faecal coliforms and heterotrophic bacteria were carried out to characterize the aquatic environmental sampled. The yeast counts were higher in aquatic environments with the highest counts of coliform and heterotrophic bacteria. These environments receive a high influx of domestic and industrial waste. A total of 317 isolates identified in forty eight yeast species were recorded in the sites sampled and the specie Aureobasidium pullulans were found in eleven out of eighteen sites sampled and some opportunistic pathogens such as the yeast species Candida krusei were isolated only in the polluted rivers with a positive correlation with the biotic and abiotic parameters that indicate sewage contamination. PMID:24031990

  17. How long can culturable bacteria and total DNA persist in environmental waters? The role of sunlight and solid particles.

    PubMed

    Gutiérrez-Cacciabue, Dolores; Cid, Alicia G; Rajal, Verónica B

    2016-01-01

    In this work, sunlight inactivation of two indicator bacteria in freshwater, with and without solid particles, was studied and the persistence of culturable cells and total DNA was compared. Environmental water was used to prepare two matrices, with and without solid particles, which were spiked with Escherichia coli and Enterococcus faecalis. These matrices were used to prepare microcosm bags that were placed in two containers: one exposed to sunlight and the other in the dark. During one month, samples were removed from each container and detection was done by membrane filter technique and real-time PCR. Kinetic parameters were calculated to assess sunlight effect. Indicator bacteria without solid particles exposed to sunlight suffered an immediate decay (<4h) compared with the ones which were shielded from them. In addition, the survival of both bacteria with solid particles varied depending on the situation analyzed (T99 from 3 up to 60days), being always culturable E. coli more persistent than E. faecalis. On the other side, E. faecalis DNA persisted much longer than culturable cells (T99>40h in the dark with particles). In this case active cells were more prone to sunlight than total DNA and the protective effect of solid particles was also observed. Results highlight that the effects caused by the parameters which describe the behavior of culturable microorganisms and total DNA in water are different and must be included in simulation models but without forgetting that these parameters will also depend on bacterial properties, sensitizers, composition, type, and uses of the aquatic environment under assessment. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Effect of edible chitosan/clove oil films and high-pressure processing on the microbiological shelf life of trout fillets.

    PubMed

    Albertos, Irene; Rico, Daniel; Diez, Ana María; González-Arnáiz, Lucía; García-Casas, María Jesús; Jaime, Isabel

    2015-11-01

    The inhibitory effect of chitosan films with clove oil (0-50 g kg(-1) ) was evaluated on a range of ten representative food spoilage and pathogenic bacteria. The most sensitive bacteria to the films was Shewanella putrefaciens and the most resistant was Aeromonas hydrophila (inhibition was apparent only at 50 g kg(-1) clove essential oil (CEO)). Films with 20 g kg(-1) CEO inhibited nine of ten of the bacteria tested. Chitosan films with 20 g kg(-1) CEO were combined with high-pressure (HPP) processing as treatments for trout fillets, and changes in physicochemical parameters and microbial load were evaluated at 4 °C over 22 days of storage. The films reduced weight loss and water activity compared to fresh and treated samples (HPP and cooking). Results showed that microbial load (total aerobic mesophilic, lactic acid bacteria and total coliform) of the trout fillets covered with chitosan films was lower than that for HPP-treated samples, and similar to cooked samples, except for coliform counts. The use of 20 g kg(-1) CEO-chitosan films showed a further improvement in the shelf-life of trout fillets when compared to that obtained with HPP and cooking treatment. © 2014 Society of Chemical Industry.

  19. Behavior of microorganisms in drinking water treatment by inductively coupled plasma system: Case study in ground water

    NASA Astrophysics Data System (ADS)

    Desmiarti, Reni; Hazmi, Ariadi; Martynis, Munas; Sutopo, Ulung Muhammad; Li, Fusheng

    2018-02-01

    Pathogenic bacteria, such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC), were removed from groundwater by inductively coupled plasma system treatment in continuous flow experiments. The objective of this study is to investigate the effect of flowrate and frequency on the behavior of microorganisms in drinking water treatment using inductively coupled plasma system (ICPS). The results showed that after 120 minutes of ICPS treatment, the removal efficiency with respect to TC, FC and OC decreased with increasing flowrate. The removal efficiency of FC was achieved at 100% in all runs. Compared to FC, the removal efficiencies with respect to TC and FC were lower than those with respect to TC and OC in the following order: FC >OC> TC. The disinfection yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 8.08±0.46 to 10.54±0.19 W/cm2. The results in the present work can be used to design a new technology for drinking water treatment to remove all pathogenic bacteria without using hazardous chemicals.

  20. Total lactic acid bacteria, antioxidant activity, and acceptance of synbiotic yoghurt with red ginger extract (Zingiberofficinale var. rubrum)

    NASA Astrophysics Data System (ADS)

    Larasati, B. A.; Panunggal, B.; Afifah, D. N.; Anjani, G.; Rustanti, N.

    2018-02-01

    Antioxidant related to oxidative stress can caused the metabolic disorders. A functional food that high in antioxidant can be use as the alternative prevention. The addition of red ginger extract in yoghurt could form a functional food, that high in antioxidant, synbiotic and fiber. The influence of red ginger extract on yoghurt synbiotic against lactic acid bacteria, antioxidant activity and acceptance were analyzed. This was an experimental research with one factor complete randomized design, specifically the addition of red ginger extract 0%; 0,1%; 0,3% and 0,5% into synbiotic yoghurt. Total plate count method used to analyze the lactic acid bacteria, 1-1-diphenyl-2-picrylhydrazyl (DPPH) method for antioxidant activity, and acceptance analyzed with hedonic test. The higher the dose of extract added to synbiotic yoghurt, the antioxidant activity got significantly increased (ρ=0,0001), while the lactic acid bacteria got insignificantly decreased (ρ=0,085). The addition of 0,5% red ginger extract obtained the antioxidant activity of 71% and 4,86 × 1013 CFU/ml on lactic acid bacteria, which the requirement for probiotic on National Standard of Indonesia is >107 CFU/ml. The addition of extract had a significant effect on acceptance (ρ=0,0001) in flavor, color, and texture, but not aroma (ρ=0,266). The optimal product in this research was the yoghurt synbiotic with addition of 0,1% red ginger extract. To summarize, the addition of red ginger extract in synbiotic yoghurt had significant effect on antioxidant activity, flavor, color, and texture, but no significant effect on lactic acid bacteria and aroma.

  1. Bathymetric mapping, sediment quality, and water quality of Lake Delhi, Iowa, 2001-02

    USGS Publications Warehouse

    Schnoebelen, Douglas J.; McVay, Jason C.; Barnes, Kimberlee K.; Becher, Kent D.

    2003-01-01

    Water-quality sampling results indicate areas affected by elevated nutrient and bacteria concentrations in the lake and tributary streams. The tributary streams had the highest median nitrate concentrations (12.1 milligrams per liter) when compared to median nitrate concentrations in the lake (8.7 milligrams per liter) or the Maquoketa River (10.5 milligrams per liter). The maximum nitrate concentrations detected for Maquoketa River, lake, and tributary sites were 13.5, 13.5, and 18.6 milligrams per liter, respectively. Nitrate concentrations in the late summer decreased from 2 Bathymetric Mapping, Sediment Quality, and Water Quality of Lake Delhi, Iowa, 2001–02 the upstream (7.8 milligrams per liter) to the downstream (5.0 milligrams per liter) one-third of Lake Delhi and most likely were the result of uptake of nitrate by algae and aquatic biota in the lake. Median concentrations of total coliform and E. coli bacteria for the lake sites were 450 and 17 colonies per 100 milliliters of sample, respectively. The U.S. Environmental Protection Agency criteria for full body contact (swimming or bathing) are 200 colonies per 100 milliliters for fecal bacteria and 126 colonies per 100 milliliters for E. coli bacteria. The highest bacteria concentrations in the lake occurred after a rain and were 25,000 colonies per 100 milliliters total coliform and 1,900 colonies per 100 milliliters E. coli.

  2. Impact of urban contamination of the La Paz River basin on thermotolerant coliform density and occurrence of multiple antibiotic resistant enteric pathogens in river water, irrigated soil and fresh vegetables.

    PubMed

    Poma, Violeta; Mamani, Nataniel; Iñiguez, Volga

    2016-01-01

    La Paz River in Andean highlands is heavily polluted with urban run-off and further contaminates agricultural lowlands and downstream waters at the Amazon watershed. Agricultural produce at this region is the main source of vegetables for the major Andean cities of La Paz and El Alto. We conducted a 1 year study, to evaluate microbial quality parameters and occurrence of multiple enteropathogenic bacteria (Enterohemorrhagic E. coli-EHEC, Enteroinvasive E. coli or Shigella-EIEC/Shigella, Enteroaggregative E. coli-EAEC, Enteropathogenic E. coli-EPEC Enterotoxigenic E. coli-ETEC and Salmonella) and its resistance to 11 antibiotics. Four sampling locations were selected: a fresh mountain water reservoir (un-impacted, site 1) and downstream sites receiving wastewater discharges (impacted, sites 2-4). River water (sites 1-4, N = 48), and soil and vegetable samples (site 3, N = 24) were collected during dry (April-September) and rainy seasons (October-March). Throughout the study, thermotolerant coliform density values at impacted sites greatly exceeded the guidelines for recreational and agricultural water uses. Seasonal differences were found for thermotolerant coliform density during dry season in water samples nearby a populated and hospital compound area. In contrast to the un-impacted site, where none of the tested enteropathogens were found, 100 % of surface water, 83 % of soil and 67 % of vegetable samples at impacted sites, were contaminated with at least one enteropathogen, being ETEC and Salmonella the most frequently found. ETEC isolates displayed different patterns of toxin genes among sites. The occurrence of enteropathogens was associated with the thermotolerant coliform density. At impacted sites, multiple enteropathogens were frequently found during rainy season. Among isolated enteropathogens, 50 % were resistant to at least two antibiotics, with resistance to ampicillin, nalidixic acid, trimethoprim-sulfamethoxazole and tetracycline commonly

  3. Comparative study of enteric viruses, coliphages and indicator bacteria for evaluating water quality in a tropical high-altitude system.

    PubMed

    Espinosa, Ana C; Arias, Carlos F; Sánchez-Colón, Salvador; Mazari-Hiriart, Marisa

    2009-10-27

    Bacteria used as indicators for pathogenic microorganisms in water are not considered adequate as enteric virus indicators. Surface water from a tropical high-altitude system located in Mexico City that receives rainwater, treated and non-treated wastewater used for irrigation, and groundwater used for drinking, was studied. The presence of enterovirus, rotavirus, astrovirus, coliphage, coliform bacteria, and enterococci was determined during annual cycles in 2001 and 2002. Enteric viruses in concentrated water samples were detected by reverse transcriptase-polymerase chain reaction (RT-PCR). Coliphages were detected using the double agar layer method. Bacteria analyses of the water samples were carried out by membrane filtration. The presence of viruses and bacteria in the water used for irrigation showed no relationship between current bacterial indicator detection and viral presence. Coliphages showed strong association with indicator bacteria and enterovirus, but weak association with other enteric viruses. Enterovirus and rotavirus showed significant seasonal differences in water used for irrigation, although this was not clear for astrovirus. Coliphages proved to be adequate faecal pollution indicators for the irrigation water studied. Viral presence in this tropical high-altitude system showed a similar trend to data previously reported for temperate zones.

  4. Decontamination of drinking water by direct heating in solar panels.

    PubMed

    Fjendbo Jørgensen, A J; Nøhr, K; Sørensen, H; Boisen, F

    1998-09-01

    A device was developed for direct heating of water by solar radiation in a flow-through system of copper pipes. An adjustable thermostat valve prevents water below the chosen temperature from being withdrawn. The results show that it is possible to eliminate coliform and thermotolerant coliform bacteria from naturally contaminated river water by heating to temperatures of 65 degrees C or above. Artificial additions of Salmonella typhimurium, Streptococcus faecalis and Escherichia coli to contaminated river water were also inactivated after heating to 65 degrees C and above. The total viable count could be reduced by a factor of 1000. The heat-resistant bacteria isolated from the Mlalakuva River (Tanzania) were spore-forming bacteria which exhibited greater heat resistance than commonly used test bacteria originating from countries with colder climates. To provide a good safety margin it is recommended that an outlet water temperature of 75 degrees C be used. At that temperature the daily production was about 501 of decontaminated water per m2 of solar panel, an amount that could be doubled by using a heat exchanger to recycle the heat.

  5. Effect of anaerobic digestion temperature on odour, coliforms and chlortetracycline in swine manure or monensin in cattle manure.

    PubMed

    Varel, V H; Wells, J E; Shelver, W L; Rice, C P; Armstrong, D L; Parker, D B

    2012-04-01

    This study evaluated the effect of anaerobic digestion at 22, 38 and 55°C on odour, coliforms and chlortetracycline (CTC) in swine manure or monensin (MON) in cattle manure. Swine or cattle were fed the respective growth promotant, manure was collected, and 2-l laboratory methane digesters were established at the various temperatures and sampled over 25 or 28 days. After 21 days, the concentration of CTC in the 22, 38 and 55°C swine digester slurries decreased 7, 80 and 98%, respectively. Coliforms in the 22°C digester slurries were still viable after 25 days; however, they were not detectable in the 38 and 55°C slurries after 3 and 1 days, respectively. After 28 days, the concentration of MON in the 22, 38 and 55°C cattle digester slurries decreased 3, 8 and 27%, respectively. Coliforms in the 22°C cattle digester slurries were still viable after 28 days; however, they were not detectable in the 38 and 55°C slurries after 14 and 1 days, respectively. These studies indicate that anaerobic digestion at 38 or 55°C may be an effective treatment to reduce coliforms and CTC; however, it is not an effective treatment to reduce MON. More studies are needed to determine which pharmaceuticals are susceptible to degradation by a specific manure treatment to prevent negative environmental consequences. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.

  6. Containing antibiotic resistance: decreased antibiotic-resistant coliform urinary tract infections with reduction in antibiotic prescribing by general practices

    PubMed Central

    Butler, Chris C; Dunstan, Frank; Heginbothom, Margaret; Mason, Brendan; Roberts, Zoë; Hillier, Sharon; Howe, Robin; Palmer, Stephen; Howard, Anthony

    2007-01-01

    Background GPs are urged to prescribe antibiotics less frequently, despite lack of evidence linking reduced antibiotic prescribing with reductions in resistance at a local level. Aim To investigate associations between changes in antibiotic dispensing and changes in antibiotic resistance at general-practice level. Design of study Seven-year study of dispensed antibiotics and antibiotic resistance in coliform isolates from urine samples routinely submitted from general practice. Setting General practices in Wales. Method Multilevel modelling of trends in resistance to ampicillin and trimethoprim, and changes in practice total antibiotic dispensing and amoxicillin and trimethoprim dispensing. Results The primary analysis included data on 164 225 coliform isolates from urine samples submitted from 240 general practices over the 7-year study period. These practices served a population of 1.7 million patients. The quartile of practices that had the greatest decrease in total antibiotic dispensing demonstrated a 5.2% reduction in ampicillin resistance over the 7-year period with changes of 0.4%, 2.4%, and −0.3% in the other three quartiles. There was a statistically significant overall decrease in ampicillin resistance of 1.03% (95% confidence interval [CI] = 0.37 to 1.67%) per decrease of 50 amoxicillin items dispensed per 1000 patients per annum. There were also significant reductions in trimethoprim resistance in the two quartiles of practices that reduced total antibiotic dispensing most compared with those that reduced it least, with an overall decrease in trimethoprim resistance of 1.08% (95% CI = 0.065 to 2.10%) per decrease of 20 trimethoprim items dispensed per 1000 patients per annum. Main findings were confirmed by secondary analyses of 256 370 isolates from 527 practices that contributed data at some point during the study period. Conclusion Reducing antibiotic dispensing at general-practice level is associated with reduced local antibiotic resistance

  7. Resistance to quaternary ammonium compounds in food-related bacteria.

    PubMed

    Sidhu, Maan Singh; Sørum, Henning; Holck, Askild

    2002-01-01

    Microbial resistance to antimicrobial agents continues to be a major problem. The frequent use and misuse of disinfectants based on quaternary ammonium compounds (QACs) in food-processing industries have imposed a selective pressure and may contribute to the emergence of disinfectant-resistant microorganisms. A total number of 1,325 Gram-negative isolates (Escherichia coli, other coliforms Vibrio spp., and Aeromonas spp.) and 500 Enterococcus spp. from food and food-processing industries and fish farming were screened for natural resistance to the QAC-based disinfectant benzalkonium chloride (BC). Of the 1,825 isolates, 16 strains, mainly from meat retail shops, showed low-level resistance to BC. None of the Enterococcus spp. from broiler, cattle, and pigs, the antibiotic-resistant E. coli from pig intestine and fish pathogens Vibrio spp. and Aeromonas spp. from the Norwegian fish farming industry were resistant to BC. The BC-resistant strains were examined for susceptibility to 15 different antibiotics, disinfectants, and dyes. No systematic cross-resistance between BC and any of the other antimicrobial agents tested was detected. Stable enhanced resistance in Enterobacter cloacae isolates was demonstrated by step-wise adaptation in increasing concentrations of BC. In conclusion, BC resistance among food-associated Gram-negative bacteria and Enterococcus spp. is not frequent, but resistance may develop to user concentrations after exposure to sublethal concentrations of BC.

  8. A Systematic Review and Meta-Analysis of Fecal Contamination and Inadequate Treatment of Packaged Water

    PubMed Central

    Williams, Ashley R.; Bain, Robert E. S.; Fisher, Michael B.; Cronk, Ryan; Kelly, Emma R.; Bartram, Jamie

    2015-01-01

    Background Packaged water products provide an increasingly important source of water for consumption. However, recent studies raise concerns over their safety. Objectives To assess the microbial safety of packaged water, examine differences between regions, country incomes, packaged water types, and compare packaged water with other water sources. Methods We performed a systematic review and meta-analysis. Articles published in English, French, Portuguese, Spanish and Turkish, with no date restrictions were identified from online databases and two previous reviews. Studies published before April 2014 that assessed packaged water for the presence of Escherichia coli, thermotolerant or total coliforms were included provided they tested at least ten samples or brands. Results A total of 170 studies were included in the review. The majority of studies did not detect fecal indicator bacteria in packaged water (78/141). Compared to packaged water from upper-middle and high-income countries, packaged water from low and lower-middle-income countries was 4.6 (95% CI: 2.6–8.1) and 13.6 (95% CI: 6.9–26.7) times more likely to contain fecal indicator bacteria and total coliforms, respectively. Compared to all other packaged water types, water from small bottles was less likely to be contaminated with fecal indicator bacteria (OR = 0.32, 95%CI: 0.17–0.58) and total coliforms (OR = 0.10, 95%CI: 0.05, 0.22). Packaged water was less likely to contain fecal indicator bacteria (OR = 0.35, 95%CI: 0.20, 0.62) compared to other water sources used for consumption. Conclusions Policymakers and regulators should recognize the potential benefits of packaged water in providing safer water for consumption at and away from home, especially for those who are otherwise unlikely to gain access to a reliable, safe water supply in the near future. To improve the quality of packaged water products they should be integrated into regulatory and monitoring frameworks. PMID:26505745

  9. Survival and leaching of fecal bacteria after slurry spreading on mountain hay meadows: consequences for the management of water contamination risk.

    PubMed

    Trevisan, D; Vansteelant, J Y; Dorioz, J M

    2002-01-01

    The aim of this work is to achieve a better understanding of the behavior of fecal coliform populations on the vegetation and in the soil after slurry spreading in environmental conditions, typical of vegetative growth period in mountain hay meadows. Changes in fecal coliform populations on the vegetation and in the soil were monitored in situ for 3 months after slurry spreading on 9 plots. The variations found in populations are related to the agricultural, soil. and climatic characteristics of plots and to the moisture regime of soils. These observations are compared with laboratory experiments on undisturbed soil microcosms. In absence of water flux, survival durations recorded in the laboratory and in the field are of the same order of magnitude. The data enable us to pinpoint the influence of various factors affecting the decline and transfer of fecal bacteria in the plant-soil system and consequently to discuss the risk management of water contamination by agriculture.

  10. First Report on a Randomized Investigation of Antimicrobial Resistance in Fecal Indicator Bacteria from Livestock, Poultry, and Humans in Tanzania.

    PubMed

    Katakweba, Abdul A S; Muhairwa, Amandus P; Lupindu, Athumani M; Damborg, Peter; Rosenkrantz, Jesper T; Minga, Uswege M; Mtambo, Madundo M A; Olsen, John E

    2018-04-01

    This study provides an estimate of antimicrobial resistance in intestinal indicator bacteria from humans (n = 97) and food animals (n = 388) in Tanzania. More than 70% of all fecal samples contained tetracycline (TE), sulfamethoxazole (STX), and ampicillin (AMP)-resistant coliforms, while cefotaxime (CTX)-resistant coliforms were observed in 40% of all samples. The average Log 10 colony forming units/g of CTX-resistant coliforms in samples from humans were 2.20. Of 390 Escherichia coli tested, 66.4% were resistant to TE, 54.9% to STX, 54.9% to streptomycin, and 36.4% to CTX. Isolates were commonly (65.1%) multiresistant. All CTX-resistant isolates contained bla CTX-M gene type. AMP- and vancomycin-resistant enterococci were rare, and the average concentrations in positive samples were low (log 10 0.9 and 0.4, respectively). A low-to-moderate resistance (2.1-15%) was detected in 240 enterococci isolates to the drugs tested, except for rifampicin resistance (75.2% of isolates). The average number of sulII gene copies varied between Log 10 5.37 and 5.68 with no significant difference between sample source, while cattle had significantly higher number of tetW genes than humans. These findings, based on randomly obtained samples, will be instrumental in designing antimicrobial resistance (AMR) intervention strategies for Tanzania.

  11. Seasonal Microbial Conditions of Locally Made Yoghurt (Shalom) Marketed in Some Regions of Cameroon

    PubMed Central

    Moh, Lamye Glory; Keilah, Lunga Paul; Etienne, Pamo Tedonkeng

    2017-01-01

    The microbial conditions of locally made yoghurt (shalom) marketed in three areas of Cameroon were evaluated during the dry and rainy seasons alongside three commercial brands. A total of ninety-six samples were collected and the microbial conditions were based on total aerobic bacteria (TEB), coliforms, yeasts, and moulds counts as well as the identification of coliforms and yeasts using identification kits. Generally, there was a significant increase (p ≤ 0.05) in total aerobic and coliform counts (especially samples from Bamenda), but a decrease in yeast and mould counts of the same samples during the rainy season when compared to those obtained during the dry season. These counts were mostly greater than the recommended standards. Twenty-one Enterobacteriaceae species belonging to 15 genera were identified from 72 bacterial isolates previously considered as all coliforms. Pantoea sp. (27.77%) was highly represented, found in 41% (dry season) and 50% (rainy season) of samples. In addition, sixteen yeast species belonging to 8 genera were equally identified from 55 yeast isolates and Candida sp. (76.36%) was the most represented. This result suggests that unhygienic practices during production, ignorance, warmer weather, duration of selling, and inadequate refrigeration are the principal causes of higher levels of contamination and unsafe yoghurts. PMID:29423400

  12. Comparative reduction of Giardia cysts, F+ coliphages, sulphite reducing clostridia and fecal coliforms by wastewater treatment processes.

    PubMed

    Nasser, Abidelfatah M; Benisti, Neta-Lee; Ofer, Naomi; Hovers, Sivan; Nitzan, Yeshayahu

    2017-01-28

    Advanced wastewater treatment processes are applied to prevent the environmental dissemination of pathogenic microorganisms. Giardia lamblia causes a severe disease called giardiasis, and is highly prevalent in untreated wastewater worldwide. Monitoring the microbial quality of wastewater effluents is usually based on testing for the levels of indicator microorganisms in the effluents. This study was conducted to compare the suitability of fecal coliforms, F+ coliphages and sulfide reducing clostridia (SRC) as indicators for the reduction of Giardia cysts in two full-scale wastewater treatment plants. The treatment process consists of activated sludge, coagulation, high rate filtration and either chlorine or UV disinfection. The results of the study demonstrated that Giardia cysts are highly prevalent in raw wastewater at an average concentration of 3600 cysts/L. Fecal coliforms, F+ coliphages and SRC were also detected at high concentrations in raw wastewater. Giardia cysts were efficiently removed (3.6 log 10 ) by the treatment train. The greatest reduction was observed for fecal coliforms (9.6 log 10 ) whereas the least reduction was observed for F+ coliphages (2.1 log 10 ) following chlorine disinfection. Similar reduction was observed for SRC by filtration and disinfection by either UV (3.6 log 10 ) or chlorine (3.3 log 10 ). Since F+ coliphage and SRC were found to be more resistant than fecal coliforms for the tertiary treatment processes, they may prove to be more suitable as indicators for Giardia. The results of this study demonstrated that advanced wastewater treatment may prove efficient for the removal of Giardia cysts and may prevent its transmission when treated effluents are applied for crop irrigation or streams restoration.

  13. MEMBRANE FILTER PROCEDURE FOR ENUMERATING THE COMPONENT GENERA OF THE COLIFORM GROUP IN SEAWATER

    EPA Science Inventory

    A facile, quantitative, membrane filter procedure (mC) for defining the distribution of coliform populations in seawater according to the component genera was developed. The procedure, which utilizes a series of in situ substrate tests to obviate the picking of colonies for ident...

  14. Ground-water-quality data for selected wells in the Beaver Creek watershed, West Tennessee

    USGS Publications Warehouse

    Williams, S.D.

    1996-01-01

    In 1993 the U.S. Geological Survey, in cooperation with the Tennessee Department of Environment and Conservation (TDEC), began an investigation of the quality of ground water in the Beaver Creek watershed in West Tennessee. A total of 408 water samples were collected from 91 wells during 5 sampling periods in 1994. Water samples were analyzed for selected water-quality properties, fecal coliform and streptococci bacteria, nutrients, and major inorganic constituents. Selected well- construction data and information on potential sources of contamination were also collected for the 91 wells sampled. Nitrate concentrations (measured as NO3) ranged from a detection limit of 0.1 to 91 milligrams per liter (mg/L). Nitrate concentrations exceeding 13 mg/L were detected in 71 of the samples collected. Nitrate concentrations in water samples collected from three wells exceeded the TDEC primary drinking water standard of 44 mg/L for nitrate (measured as NO3). Nitrite (measured as NO2), ammonium (measured as NH4), and orthophosphate (measured as PO4) concentrations in samples were generally less than 0.1 mg/L (detection limit). Fecal coliform bacteria were detected in 33 of the 408 water samples collected. Samples from 21 of the 91 wells contained fecal coliform bacteria during one or more of the five sampling periods. Fecal streptococci bacteria were detected in 123 of the 408 samples. Samples from 59 wells contained fecal streptococci bacteria during one or more of the five sampling periods.

  15. Lactic acid bacteria and yeasts associated with spontaneous fermentations during the production of sour cassava starch in Brazil.

    PubMed

    Lacerda, Inayara C A; Miranda, Rose L; Borelli, Beatriz M; Nunes, Alvaro C; Nardi, Regina M D; Lachance, Marc-André; Rosa, Carlos A

    2005-11-25

    Sour cassava starch is a traditional fermented food used in the preparation of fried foods and baked goods such as traditional cheese breads in Brazil. Thirty samples of sour cassava starch were collected from two factories in the state of Minas Gerais. The samples were examined for the presence of lactic acid bacteria, yeasts, mesophilic microorganisms, Bacillus cereus and faecal coliforms. Lactic acid bacteria and yeasts isolates were identified by biochemical tests, and the identities were confirmed by molecular methods. Lactobacillus plantarum and Lactobacillus fermentum were the prevalent lactic acid bacteria in product from both factories, at numbers between 6.0 and 9.0 log cfu g(-)(1). Lactobacillus perolans and Lactobacillus brevis were minor fractions of the population. Galactomyces geothricum and Issatchenkia sp. were the prevalent yeasts at numbers of 5.0 log cfu g(-)(1). A species similar to Candida ethanolica was frequently isolated from one factory. Mesophilic bacteria and amylolytic microorganisms were recovered in high numbers at all stages of the fermentation. B. cereus was found at low numbers in product at both factories. The spontaneous fermentations associated with the production of sour cassava starch involve a few species of lactic acid bacteria at high numbers and a variety of yeasts at relatively low numbers.

  16. Coliphages as indicators of enteroviruses.

    PubMed Central

    Stetler, R E

    1984-01-01

    Coliphages were monitored in conjunction with indicator bacteria and enteroviruses in a drinking-water plant modified to reduce trihalomethane production. Coliphages could be detected in the source water by direct inoculation, and sufficient coliphages were detected in enterovirus concentrates to permit following the coliphage levels through different water treatment processes. The recovery efficiency by different filter types ranged from 1 to 53%. Statistical analysis of the data indicated that enterovirus isolates were better correlated with coliphages than with total coliforms, fecal coliforms, fecal streptococci, or standard plate count organisms. Coliphages were not detected in finished water. PMID:6093694

  17. Presence of faecal coliforms and selected heavy metals in ice cubes from food outlets in Taman Universiti, Johor Bahru, Malaysia.

    PubMed

    Mahat, N A; Meor Ahmad, Z; Abdul Wahab, R

    2015-09-01

    Consumption of iced beverages is common in Malaysia although specific research focusing on its safety parameters such as presence of faecal coliforms and heavy metal elements remains scarce. A study conducted in Kelantan indicated that faecal coliforms were detected in the majority of the ice cube samples analyzed, largely attributable to improper handling. Hence, it was found pertinent to conduct similar study in other parts of the country such as Johor Bahru if the similar pattern prevailed. Therefore, this present cross sectional study which randomly sampled ice cubes from 30 permanent food outlets in Taman Universiti, Johor Bahru for detecting contamination by faecal coliforms and selected heavy metal elements (lead, copper, manganese and zinc) acquires significance. Faecal coliforms were detected in 11 (36.67%) of the samples, ranging between 1 CFU/100 mL to > 50 CFU/100 mL; two of the samples were grossly contaminated (>50 CFU/100 mL). Interestingly, while positive detection of lead was observed in 29 of the 30 ice cube samples (mean: 0.511±0.105 ppm; range: 0.489-0.674 ppm), copper, manganese and zinc were not detected. In addition, analysis on commercially bottled mineral water as well as in tap water samples did not detect such contaminations. Therefore, it appears that (1) contamination of faecal coliforms in ice cubes in food outlets in Malaysia may not be sporadic in pattern but rather prevalent and (2) the source of water used for manufacturing the ice cubes that contained significant amount of lead would suggest that (3) it was neither originated from the treated tap water supply nor bottled mineral water or (4) perhaps contaminated during manufacturing process. Further studies exploring the source of water used for manufacturing these ice cubes as well as the handling process among food operators deserve consideration.

  18. Influence of storage and preservation on microbiological quality of silo ovine milk.

    PubMed

    de Garnica, M L; Santos, J A; Gonzalo, C

    2011-04-01

    This study was designed to analyze the effects of the storage and preservation conditions on counts of mesophilic, thermoduric, psychotrophic, coliform, Escherichia coli, Streptococcus agalactiae, and Staphylococcus aureus organisms in silo ovine milk. A total of 910 analytical determinations were conducted from aliquots of 10 silo ovine milks. The conditions tested were unpreserved and azidiol-preserved milk stored at 4°C, and unpreserved milk stored at -20°C. Milk aged 2, 24, 48, 72, and 96 h post-collection for refrigerated aliquots, and 7, 15, and 30 d post-collection for frozen aliquots. The factors silo and storage conditions significantly contributed to variation of all microbiological variables, although milk age effect within storage was only significant for mesophilic, psychrotrophic, and coliform bacteria counts. In refrigerated raw milk, mesophile, psychrotroph, and coliform counts significantly increased over 96 h post-collection, whereas the other groups and bacteria species tested maintained their initial concentration. In all cases, azidiol preservation maintained the initial bacterial concentration in raw sheep milk under refrigeration throughout 96 h. Thus, azidiol was a suitable preservative for microbiological studies in sheep milk. Smallest counts were registered for frozen samples, particularly for coliforms, E. coli, Strep. agalactiae and Staph. aureus. Estimates of mesophilic, thermoduric and psychrotrophic organisms showed similar values on both azidiol-preserved and frozen milk samples. Coliforms and E. coli counts significantly decrease over time after freezing. Consequently, freezing at -20°C could also be appropriate for analysis of mesophilic, thermoduric, and psychrotrophic bacterial groups, but not for coliforms or mammary pathogens. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Microbial contamination of vegetable crop and soil profile in arid regions under controlled application of domestic wastewater

    PubMed Central

    Balkhair, Khaled S.

    2015-01-01

    Increasing lack of potable water in arid countries leads to the use of treated wastewater for crop production. However, the use of inappropriate irrigation practices could result in a serious contamination risk to plants, soils, and groundwater with sewage water. This research was initiated in view to the increasing danger of vegetable crops and groundwater contamination with pathogenic bacteria due to wastewater land application. The research was designed to study: (1) the effect of treated wastewater irrigation on the yield and microbial contamination of the radish plant under field conditions; (2) contamination of the agricultural soil profile with fecal coliform bacteria. Effluent from a domestic wastewater treatment plant (100%) in Jeddah city, Saudi Arabia, was diluted to 80% and 40% with the groundwater of the experimental site constituting three different water qualities plus groundwater as control. Radish plant was grown in two consecutive seasons under two drip irrigation systems and four irrigation water qualities. Upon harvesting, plant weight per ha, total bacterial, fecal coliform, fecal streptococci were detected per 100 g of dry matter and compared with the control. The soil profile was also sampled at an equal distance of 3 cm from soil surface for fecal coliform detection. The results indicated that the yield increased significantly under the subsurface irrigation system and the control water quality compared to surface irrigation system and other water qualities. There was a considerable drop in the count of all bacteria species under the subsurface irrigation system compared to surface irrigation. The bacterial count/g of the plant shoot system increased as the percentage of wastewater in the irrigation water increased. Most of the fecal coliform bacteria were deposited in the first few centimeters below the column inlet and the profile exponentially decreased with increasing depth. PMID:26858571

  20. Chloroxyanion residue on seeds and sprouts after chlorine dioxide sanitation of alfalfa seed

    USDA-ARS?s Scientific Manuscript database

    The effects of a 6-h chlorine dioxide sanitation of alfalfa seed (0, 50, 100, and 200 mg/kg seed) on total coliform bacteria, seed germination, and on the presence of chlorate and perchlorate residues in seed rinse, seed soak, and in alfalfa sprouts was determined. Chlorate residues in 20000 ppm cal...

  1. Persistence and diversity of faecal coliform and enterococci populations in faecally polluted waters.

    PubMed

    Bonjoch, X; García-Aljaro, C; Blanch, A R

    2011-07-01

    To assess the persistence and diversity of faecal bacterial populations (faecal coliforms and enterococci) that have recently been included in microbial source tracking (MST) predictive models. The analysed bacterial populations included members of the enterococci group (ENT) [Enterococcus faecium (FM), Enterococcus faecalis (FS) and Enterococcus hirae (HIR)] and the faecal coliform group (FC) [diverse Escherichia coli phenotypes (ECP) and cellobiose-negative faecal coliforms (CNFC)]. The inactivation of these distinct groups was monitored over time on-site in river by biochemical fingerprinting, and diversity indices were calculated. Among the different analysed species belonging to the ENT group, HIR persisted longer and was able to replicate in the environment at a higher rate. On the other hand, ECP and NCFC showed a similar persistence throughout the different seasons. The diversity index (Di) for FC increased substantially in the summer after 96 h to a maximum value of 0·96. On the other hand, the Di for ENT diminished over the same period to a value of 0·86, suggesting a different persistence for the different species integrating this group. The persistence of ECP, CNFC, FM and FS in the aquatic environment is high, particularly for the members of the FC and in the summer season. On the contrary, HIR is able to replicate in the environment at a high rate even in winter, and therefore, its inclusion in MST predictive models is discouraged. ECP, CNFC, FMFS and HIR have been proposed as additional variables in MST predictive models. However, the different persistence of HIR compared with the other variables should be taken into account for the development of such models. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.

  2. Comparative study of enteric viruses, coliphages and indicator bacteria for evaluating water quality in a tropical high-altitude system

    PubMed Central

    2009-01-01

    Background Bacteria used as indicators for pathogenic microorganisms in water are not considered adequate as enteric virus indicators. Surface water from a tropical high-altitude system located in Mexico City that receives rainwater, treated and non-treated wastewater used for irrigation, and groundwater used for drinking, was studied. Methods The presence of enterovirus, rotavirus, astrovirus, coliphage, coliform bacteria, and enterococci was determined during annual cycles in 2001 and 2002. Enteric viruses in concentrated water samples were detected by reverse transcriptase-polymerase chain reaction (RT-PCR). Coliphages were detected using the double agar layer method. Bacteria analyses of the water samples were carried out by membrane filtration. Results The presence of viruses and bacteria in the water used for irrigation showed no relationship between current bacterial indicator detection and viral presence. Coliphages showed strong association with indicator bacteria and enterovirus, but weak association with other enteric viruses. Enterovirus and rotavirus showed significant seasonal differences in water used for irrigation, although this was not clear for astrovirus. Conclusion Coliphages proved to be adequate faecal pollution indicators for the irrigation water studied. Viral presence in this tropical high-altitude system showed a similar trend to data previously reported for temperate zones. PMID:19860917

  3. Contribution of aerobic anoxygenic phototrophic bacteria to total organic carbon pool in aquatic system of subtropical karst catchments, Southwest China: evidence from hydrochemical and microbiological study.

    PubMed

    Li, Qiang; Song, Ang; Peng, Wenjie; Jin, Zhenjiang; Müller, Werner E G; Wang, Xiaohong

    2017-06-01

    Aerobic anoxygenic phototrophic bacteria may play a particular role in carbon cycling of aquatic systems. However, little is known about the interaction between aerobic anoxygenic phototrophic bacteria and hydrochemistry in groundwater-surface water exchange systems of subtropical karst catchments. We carried out a detailed study on the abundance of aerobic anoxygenic phototrophic bacteria and bacterioplankton, hydrochemistry and taxonomy of bacterioplankton in the Maocun watershed, Southwest China, an area with karst geological background. Our results revealed that bacteria are the important contributors to total organic carbon source/sequestration in the groundwater-surface water of this area. The aerobic anoxygenic phototrophic bacteria, including β-Proteobacteria, also appear in the studied water system. In addition to that, the genus Polynucleobacter of the phototropic β-Proteobacteria shows a close link with those sampling sites by presenting bacterial origin organic carbon on CCA biplot and is found to be positively correlated with total nitrogen, dissolved oxygen and pH (r = 0.860, 0.747 and 0.813, respectively) in the Maocun watershed. The results suggest that Polynucleobacter might be involved in the production of organic carbon and might act as the negative feedback on global warming. © FEMS 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Effect of oral administration of Bacillus coagulans B37 and Bacillus pumilus B9 strains on fecal coliforms, Lactobacillus and Bacillus spp. in rat animal model

    PubMed Central

    Haldar, Lopamudra; Gandhi, D. N.

    2016-01-01

    Aim: To investigate the effect of oral administration of two Bacillus strains on fecal coliforms, Lactobacillus and Bacillus spp. in rat animal model. Materials and Methods: An in vivo experiment was conducted for 49-day period on 36 adult male albino Wister rats divided equally into to four groups. After 7-day adaptation period, one group (T1) was fed on sterile skim milk along with basal diet for the next 28 days. Second (T2) and (T3) groups received spore biomass of Bacillus coagulans B37 and Bacillus pumilus B9, respectively, suspended in sterilized skim milk at 8-9 log colony-forming units/ml plus basal diet for 28 days, while control group (T4) was supplied with clean water along with basal diet. There was a 14-day post-treatment period. A total of 288 fecal samples (8 fecal collections per rat) were collected at every 7-day interval starting from 0 to 49 days and subjected to the enumeration of the counts of coliforms and lactobacilli and Bacillus spores using respective agar media. In vitro acid and bile tolerance tests on both the strains were performed. Results: The rats those (T2 and T3) received either B. coagulans B37 or B. pumilus B9 spore along with non-fermented skim milk showed decrease (p<0.01) in fecal coliform counts and increase (p<0.05) in both fecal lactobacilli and Bacillus spore counts as compared to the control group (T4) and the group fed only skim milk (T1). In vitro study indicated that both the strains were found to survive at pH 2.0 and 3.0 even up to 3 h and tolerate bile up to 2.0% concentration even after 12 h of exposure. Conclusions: This study revealed that oral administration of either B. coagulans B37 or B. pumilus B9 strains might be useful in reducing coliform counts accompanied by concurrent increase in lactobacilli counts in the intestinal flora in rats. PMID:27536040

  5. Effect of oral administration of Bacillus coagulans B37 and Bacillus pumilus B9 strains on fecal coliforms, Lactobacillus and Bacillus spp. in rat animal model.

    PubMed

    Haldar, Lopamudra; Gandhi, D N

    2016-07-01

    To investigate the effect of oral administration of two Bacillus strains on fecal coliforms, Lactobacillus and Bacillus spp. in rat animal model. An in vivo experiment was conducted for 49-day period on 36 adult male albino Wister rats divided equally into to four groups. After 7-day adaptation period, one group (T1) was fed on sterile skim milk along with basal diet for the next 28 days. Second (T2) and (T3) groups received spore biomass of Bacillus coagulans B37 and Bacillus pumilus B9, respectively, suspended in sterilized skim milk at 8-9 log colony-forming units/ml plus basal diet for 28 days, while control group (T4) was supplied with clean water along with basal diet. There was a 14-day post-treatment period. A total of 288 fecal samples (8 fecal collections per rat) were collected at every 7-day interval starting from 0 to 49 days and subjected to the enumeration of the counts of coliforms and lactobacilli and Bacillus spores using respective agar media. In vitro acid and bile tolerance tests on both the strains were performed. The rats those (T2 and T3) received either B. coagulans B37 or B. pumilus B9 spore along with non-fermented skim milk showed decrease (p<0.01) in fecal coliform counts and increase (p<0.05) in both fecal lactobacilli and Bacillus spore counts as compared to the control group (T4) and the group fed only skim milk (T1). In vitro study indicated that both the strains were found to survive at pH 2.0 and 3.0 even up to 3 h and tolerate bile up to 2.0% concentration even after 12 h of exposure. This study revealed that oral administration of either B. coagulans B37 or B. pumilus B9 strains might be useful in reducing coliform counts accompanied by concurrent increase in lactobacilli counts in the intestinal flora in rats.

  6. Feeding untreated and pasteurized waste milk and bulk milk to calves: effects on calf performance, health status and antibiotic resistance of faecal bacteria.

    PubMed

    Aust, V; Knappstein, K; Kunz, H-J; Kaspar, H; Wallmann, J; Kaske, M

    2013-12-01

    Non-saleable milk (waste milk, WM) is contaminated with an undefined spectrum of potentially harmful pathogens and antimicrobial residues. The objective of this study was to determine the impact of feeding bulk milk (BM) or WM - both pasteurized or not - on calf performance, health and the antibiotic resistance of specific faecal bacteria. A total of 114 calves from a large-scale dairy were housed outdoors in individual hutches and were randomly assigned to one of four feeding groups. The calves were fed either WM, pasteurized WM (pWM), BM or pasteurized BM (pBM) from day 3 to 56 of life. Milk samples taken from the pasteurizer and calves' nipple buckets were investigated at regular intervals for total plate count and counts of thermoduric bacteria, coliforms and mastitis pathogens. Faecal samples were taken on days 2, 14, 28 and 56 of life from randomly selected calves of the WM, pWM and BM groups (each N = 8-9) and processed to obtain from each sample preferably two isolates of Escherichia (E.) coli and Enterococcus spp. respectively. Isolates were tested for their antimicrobial susceptibility to 25 antimicrobial agents by broth microdilution. Daily weight gain, milk and calf starter intake and health parameters did not differ significantly between the calves of the four feeding groups. The proportion of resistant E. coli isolates was significantly higher in calves fed WM and in calves fed pWM (most pronounced for cephalosporins) than in calves receiving BM. No differences in resistance were found for Enterococus spp. Thus, the concerns for selecting resistant faecal bacteria by feeding WM seem to be justified. Nonetheless, pasteurized WM of cows not treated with antimicrobials represents an acceptable feed for young calves. © 2012 Blackwell Verlag GmbH.

  7. Significance of Fecal Coliform-Positive Klebsiella1

    PubMed Central

    Bagley, Susan T.; Seidler, Ramon J.

    1977-01-01

    A total of 191 Klebsiella pneumoniae isolates of human clinical, bovine mastitis, and a wide variety of environmental sources were tested for fecal coliform (FC) response with the membrane filtration and most probable number techniques. Twenty-seven Escherichia coli cultures of human clinical and environmental origins were also tested. Eighty-five percent (49/58) of known pathogenic K. pneumoniae were FC positive, compared with 16% (19/120) of the environmental strains. E. coli results indicated 93% (13/14) of the clinical and 85% (11/13) of the environmental strains as FC positive. There was no significant difference in the incidence of FC-positive cultures between pathogenic Klebsiella and E. coli. pH measurements of K. pneumoniae and E. coli cultures growing in m-FC broth at 44.5°C revealed three distinct pH ranges correlating with colony morphology. β-Galactosidase assays of Klebsiella and E. coli cultures at 44.5°C indicated all were able to hydrolyze lactose, even if they were FC negative by the membrane filtration or most probable number techniques. The FC response pattern appears stable in K. pneumoniae. Three pathogenic cultures showed no change in FC responses after 270 generations of growth in sterile pulp mill effluent. Since K. pneumoniae is carried in the gastrointestinal tract of humans and animals and 85% of the tested pathogenic strains were FC positive, the isolation of FC-positive Klebsiella organisms from the environment would indicate their fecal or clinical origin or both. The added fact that K. pneumoniae is an opportunistic pathogen of increasing importance makes the occurrence of FC-positive environmental Klebsiella, particularly in large numbers, a potential human and animal health hazard. PMID:18086

  8. A rapid and sensitive fluorimetric β-galactosidase assay for coliform detection using chlorophenol red-β-D-galactopyranoside.

    PubMed

    Sicard, Clémence; Shek, Norman; White, Dawn; Bowers, Raymond J; Brown, R Stephen; Brennan, John D

    2014-09-01

    We report on a new fluorimetric assay for β-galactosidase (β-gal) and faecal coliform bacteria that utilizes a long-wavelength dye, chlorophenol red-β-D-galactopyranoside (CPRG), that has been widely used for colorimetric assays. The novel feature of this new assay is the unexpected development of a large fluorescence response from liberated chorophenol red (CPR) upon complexation with poly-L-arginine (pR) in solution. The binding of CPR to pR occurs through the sulphonate group of CPR, causing formation of a charge-transfer complex and up to a 70-fold increase in emission intensity. A major advantage of the assay is the ability to utilize excitation and emission wavelengths in the red end of the spectrum, which avoids common interferences obtained when using UV-absorbing dyes such as 4-methylumbelliferyl-β-D-galactopyranoside. We provide data on the utility of CPRG as a fluorimetric reporter for both β-gal and Escherichia coli ATCC 25922 and demonstrate optimized reaction conditions for rapid and sensitive detection of E. coli at a level of 1 colony-forming unit (cfu)/10 mL after 12 h of culture followed by a 1-h assay, which is below the regulatory limit for testing of recreational water.

  9. Drinking water microbiological survey of the Northwestern State of Sinaloa, Mexico.

    PubMed

    Chaidez, Cristobal; Soto, Marcela; Martinez, Celida; Keswick, Bruce

    2008-03-01

    A potable water survey, in two important municipalities of the state of Sinaloa, Mexico was conducted. Culiacan, capital city of Sinaloa and its neighboring municipality, Navolato were selected to enumerate Aeromonas hydrophila, Escherichia coli, fecal and total coliforms, Pseudomonas aeruginosa, and Heterotrophic plate count bacteria from 100 households' taps. Manganese; residual chlorine; pH; temperature and turbidity were also examined. Overall, Aeromonas hydrophila was not detected in any of the samples, 3% contained Escherichia coli, 28% had fecal and 46 total coliforms, P. aeruginosa was present in 15% of the samples. HPC bacteria were found in all of the samples but 43% had numbers greater than 500 CFU per ml. The average numbers obtained for the physico-chemical parameters were 0.15 mg/L; 0.32 mg/L; 6.5; 28.7 degrees C and 2.92 NTU for manganese, residual chlorine, pH, temperature and turbidity, respectively. The findings of the current study demonstrate that potable water from both municipalities can harbor substantial numbers of indicator and opportunistic pathogens suggesting that additional treatment in the household may be needed.

  10. Bacteriological quality of fabrics washed at lower-than-standard temperatures in a hospital laundry facility.

    PubMed

    Christian, R R; Manchester, J T; Mellor, M T

    1983-02-01

    We determined whether the bacteriological quality of fabrics cleaned in a hospital laundry could be maintained at wash temperatures lower than 75 degrees C by the use of economically reasonable formulas and wash conditions. Three groups of bacteria were examined to determine bacteriological quality: aerobic, nonexacting chemoorganotrophs, staphylococci, and total coliforms. The distribution of bacteria on soiled fabric was patchy, with staphylococci and total coliforms ranging from less than 0.1 to greater than 4 X 10(3) CFU/cm2 and chemoorganotrophs ranging from less than 0.1 to greater than 5 X 10(5) CFU/cm2. The washing process routinely produced fabric containing less than 1 CFU/cm2. Low-temperature (47.8 to 60.0 degrees C) wash procedures eliminated all bacterial groups at least as effectively as did high-temperature procedures. The effectiveness of bacterial density reduction at low temperature was augmented by increased concentrations of bleach. Successful low-temperature washing such as that shown here may save both energy and money for hospitals.

  11. Bacteriological quality of fabrics washed at lower-than-standard temperatures in a hospital laundry facility.

    PubMed Central

    Christian, R R; Manchester, J T; Mellor, M T

    1983-01-01

    We determined whether the bacteriological quality of fabrics cleaned in a hospital laundry could be maintained at wash temperatures lower than 75 degrees C by the use of economically reasonable formulas and wash conditions. Three groups of bacteria were examined to determine bacteriological quality: aerobic, nonexacting chemoorganotrophs, staphylococci, and total coliforms. The distribution of bacteria on soiled fabric was patchy, with staphylococci and total coliforms ranging from less than 0.1 to greater than 4 X 10(3) CFU/cm2 and chemoorganotrophs ranging from less than 0.1 to greater than 5 X 10(5) CFU/cm2. The washing process routinely produced fabric containing less than 1 CFU/cm2. Low-temperature (47.8 to 60.0 degrees C) wash procedures eliminated all bacterial groups at least as effectively as did high-temperature procedures. The effectiveness of bacterial density reduction at low temperature was augmented by increased concentrations of bleach. Successful low-temperature washing such as that shown here may save both energy and money for hospitals. PMID:6830218

  12. Quality of water, Quillayute River basin, Washington

    USGS Publications Warehouse

    Fretwell, M.O.

    1984-01-01

    Groundwater in Quillayute River basin is generally of the calcium bicarbonate type, although water from some wells is affected by seawater intrusion and is predominantly of the sodium chloride type. The water is generally of excellent quality for most uses. River-water quality was generally excellent, as evaluated against Washington State water-use and water-quality criteria. Fecal coliform concentrations in all major tributaries met State water-quality criteria; water temperatures occasionally exceeded criteria maximum during periods of warm weather and low streamflow. Nutrient concentrations were generally low to very low. The four largest lakes in the basin were temperature-stratified in summer and one had an algal bloom. The Quillayute estuary had salt-wedge mixing characteristics; pollutants entering the salt wedge tended to spread to the toe of the wedge. Upwelling ocean water was the major cause of the low dissolved-oxygen concentrations observed in the estuary; ammonia concentrations in the estuary, however, were increased by the upwelling ocean waters. As in the rivers, total-coliform bacteria concentrations in the estuary were greater than fecal-coliform concentrations, indicating that many of the bacteria were of nonfecal origin and probably originated from soils. (USGS)

  13. Survival of Salmonella adelaide and fecal coliforms in coarse sands of the swan costal plain, Western Australia.

    PubMed Central

    Parker, W F; Mee, B J

    1982-01-01

    The survival of Salmonella adelaide and fecal coliforms in two coarse sands influenced by two sources of septic tank effluent was studied. The experiments were conducted in conditions that reflected the soil environment beneath functioning septic tank systems. Significant differences in survival were found with different effluent sources. In one experiment the survival of S. adelaide was similar to that of fecal coliforms; in the other it was not. The nonuniform, multiphasic nature of survival curves was variability observed in these experiments suggests that the application of such survival data for establishing management criteria for septic tank systems--by, for example, the use of soil moisture characteristic curves to give estimates of movement in the soil--is inappropriate. PMID:7103482

  14. Groundwater quality in the Lake Champlain and Susquehanna River basins, New York, 2014

    USGS Publications Warehouse

    Scott, Tia-Marie; Nystrom, Elizabeth A.; Reddy, James E.

    2016-11-04

    In a study conducted by the U.S. Geological Survey in cooperation with the New York State Department of Environmental Conservation, groundwater samples were collected from 6 production wells and 7 domestic wells in the Lake Champlain Basin and from 11 production wells and 9 domestic wells in the Susquehanna River Basin in New York. All samples were collected from June through December 2014 to characterize groundwater quality in these basins. The samples were collected and processed using standard procedures of the U.S. Geological Survey and were analyzed for 148 physiochemical properties and constituents, including dissolved gases, major ions, nutrients, trace elements, pesticides, volatile organic compounds, radionuclides, and indicator bacteria.The Lake Champlain Basin study area covers the 3,050 square miles of the basin in northeastern New York; the remaining part of the basin is in Vermont and Canada. Of the 13 wells sampled in the Lake Champlain Basin, 6 are completed in sand and gravel, and 7 are completed in bedrock. Groundwater in the Lake Champlain Basin was generally of good quality, although properties and concentrations of some constituents— fluoride, iron, manganese, dissolved solids, sodium, radon-222, total coliform bacteria, fecal coliform bacteria, and Escherichia coli bacteria—sometimes equaled or exceeded primary, secondary, or proposed drinking-water standards. The constituent most frequently detected in concentrations exceeding drinking-water standards (5 of 13 samples) was radon-222.The Susquehanna River Basin study area covers the entire 4,522 square miles of the basin in south-central New York; the remaining part of the basin is in Pennsylvania. Of the 20 wells sampled in the Susquehanna River Basin, 11 are completed in sand and gravel, and 9 are completed in bedrock. Groundwater in the Susquehanna River Basin was generally of good quality, although properties and concentrations of some constituents—pH, chloride, sodium, dissolved

  15. Quality of water, Quillayute River basin, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fretwell, M.O.

    Ground water in the Quillayute River basin is generally of the calcium bicarbonate type, although water from some wells is affected by seawater intrusion and is predominantly of the sodium chloride type. The water is generally of excellent quality for most uses, with the exception of water in two wells which had iron concentrations that potentially could be tasted in beverages and could cause staining of laundry and porcelain fixtures. A comparison of the chemical compositions of ground and surface waters showed a strong similarity over a wide geographic area. Proportions of the major chemical constituents in the rivers ofmore » the basin were nearly constant despite concentration fluctuations in response to dilution from precipitation and snowmelt. River-water quality was generally excellent, as evaluated against Washington State water use and water-quality criteria. Fecal-coliform bacteria counts generally were much lower than the total-coliform bacteria counts, indicating that most of the coliform bacteria were of nonfecal origin and probably originated in soils. Fecal coliform concentrations in all the major tributaries met State water-quality criteria. Water temperatures occasionally exceeded criteria maximum during periods of warm weather and low streamflow; dissolved-oxygen concentrations were occasionally less than criteria minimum because of increased water temperature. Both conditions occurred naturally. Nutrient concentrations were generally low to very low and about the same as in streams from virgin forestland in the Olympic National Park. However, some slight increases in nutrient concentrations were observed, particularly in the vicinity of Mill Creek and the town of Forks; due to dilution and biological assimilation, these slightly elevated concentrations decreased as the water moved downstream. 35 refs., 24 figs., 16 tabs.« less

  16. Assessing the Association between Thermotolerant Coliforms in Drinking Water and Diarrhea: An Analysis of Individual-Level Data from Multiple Studies.

    PubMed

    Hodge, James; Chang, Howard H; Boisson, Sophie; Collin, Simon M; Peletz, Rachel; Clasen, Thomas

    2016-10-01

    Fecally contaminated drinking water is believed to be a major contributor to the global burden of diarrheal disease and a leading cause of mortality among young children. However, recent systematic reviews and results from blinded studies of water quality interventions have raised questions about the risk associated with fecally contaminated water, particularly as measured by thermotolerant coliform (TTC) bacteria, a WHO-approved indicator of drinking water quality. We investigated the association between TTC in drinking water and diarrhea using data from seven previous studies. We obtained individual-level data from available field studies that measured TTC levels in household-drinking water and reported prevalence of diarrhea among household members during the days prior to the visit. The combined data set included diarrhea prevalence for 26,518 individuals and 8,000 water samples from 4,017 households, yielding 45,052 observations. The odds of diarrhea increased for each log10 increase in TTC/100 mL by 18% (95% CI: 11, 26%) for children < 5 years old and 12% (95% CI: 8, 18%) for all ages. For all ages, the odds of diarrhea increased by 21%, 35% and 49% for those whose household water samples were from 11-100, 101-1,000, and > 1,000 TTC/100 mL, respectively compared to < 1 TTC/100 mL. We found no evidence of increased odds of diarrhea with contamination levels below 11 TTC/100 mL, either in adults or children. Our analysis of individual-level data shows increased risk of diarrhea with increasing levels of TTC in drinking water. These results suggest an association between fecally contaminated water and diarrheal disease and provides support for health-based targets for levels of TTC in drinking water and for interventions to improve drinking water quality to prevent diarrhea. Hodge J, Chang HH, Boisson S, Collin SM, Peletz R, Clasen T. 2016. Assessing the association between thermotolerant coliforms in drinking water and diarrhea: an analysis of individual level

  17. Impact of mulches and growing season on indicator bacteria survival during lettuce cultivation.

    PubMed

    Xu, Aixia; Buchanan, Robert L; Micallef, Shirley A

    2016-05-02

    In fresh produce production, the use of mulches as ground cover to retain moisture and control weeds is a common agricultural practice, but the influence that various mulches have on enteric pathogen survival and dispersal is unknown. The goal of this study was to assess the impact of different mulching methods on the survival of soil and epiphytic fecal indicator bacteria on organically grown lettuce during different growing seasons. Organically managed lettuce, cultivated with various ground covers--polyethylene plastic, corn-based biodegradable plastic, paper and straw mulch--and bare ground as a no-mulch control, was overhead inoculated with manure-contaminated water containing known levels of generic Escherichia coli and Enterococcus spp. Leaves and soil samples were collected at intervals over a two week period on days 0, 1, 3, 5, 7, 10 and 14, and quantitatively assessed for E. coli, fecal coliforms and Enterococcus spp. Data were analyzed using mixed models with repeated measures and an exponential decline with asymptote survival model. Indicator bacterial concentrations in the lettuce phyllosphere decreased over time under all treatments, with more rapid E. coli declines in the fall than in the spring (p<0.01). Persistence of E. coli in spring was correlated with higher maximum and minimum temperatures in this season, and more regular rainfall. The survival model gave very good fits for the progression of E. coli concentrations in the phyllosphere over time (R(2)=0.88 ± 0.12). In the spring season, decline rates of E. coli counts were faster (2013 p=0.18; 2014 p<0.005) for the bare ground-cultivated lettuce compared to mulches. In fall 2014, the E. coli decline rate on paper mulch-grown lettuce was higher (p<0.005). Bacteria fluctuated more, and persisted longer, in soil compared to lettuce phyllosphere, and mulch type was a factor for fecal coliform levels (p<0.05), with higher counts retrieved under plastic mulches in all trials, and higher enterococci

  18. Quality assessment of rooftop runoff and harvested rainwater from a building catchment.

    PubMed

    Lee, J Y; Kim, H J; Han, M Y

    2011-01-01

    A major obstacle to the promotion of rainwater harvesting is chemical and microbiological concerns. To determine its suitability as an alternative water resource, water quality parameters such as pH, turbidity and metal ion concentrations and counted total coliform, Escherichia coli and heterotrophic bacteria were measured. It was observed that the stored rainwater had a neutral average pH and that its turbidity depended on the duration and intensity of the rainfall event. Metal concentrations were within the permissible limits specified in the Korea drinking water standard. In addition, counts of coliform, E. coli and heterotrophic bacteria were higher in the first flush 5 min after the start of the rainfall event. Principal component analysis and correlation analysis through 40 events in 2009 showed that the quality of stored rainwater depends on the conditions of the catchment and storage tank and the antecedent dry period.

  19. Microbial contamination of cosmetics and personal care items in Egypt--body lotions and talcum powders.

    PubMed

    Ashour, M S; Abdelaziz, A A; Hefni, H; el-Tayeb, O M

    1989-06-01

    We examined a total of 54 samples, including 18 body lotions and 36 talcum powders, for their total aerobic bacterial, coliform and fungal counts. We also carried out anaerobic bacterial counts for talcum powder as well as tests to detect some potentially hazardous bacteria in all tested samples. Talcum powders were more heavily contaminated with bacteria and fungi than body lotions. More than 40% of the tested body lotions contained no viable bacteria or less than 100 c.f.u./g. while all the talcum powders tested contained more than 100 c.f.u./g. Thirty per cent of the talcum powders were contaminated with 10(4) c.f.u./g. and none of the body lotions were contaminated to that extent. No coliforms were recovered from any of the body lotions, while 17% of the talcum powder examined contained coliforms in the range of 230-500 c.f.u./g. Staphylococcus spp. were detected in 18 samples of both talcum powders and body lotions, three of these Staphylococci were of the aureus type. Three samples of talcum powder contained E. coli, two samples contained Enterobacter agglomerans and one sample contained Citrobacter freundii. Seventy per cent of the body lotions showed no fungal counts, while 83% of the talcum powders examined were contaminated with fungi and most of the contaminated talcum powders contained more than 100 fungal cells/g. With regard to the anaerobic bacterial counts for talcum powders, 50% of the samples showed no counts while the other 50% contained less than 100 c.f.u./g. Four samples were contaminated with Clostridium perfringens, although C. tetani was not recovered from any of the samples.

  20. Characterization of surface-water quality based on real-time monitoring and regression analysis, Quivira National Wildlife Refuge, south-central Kansas, December 1998 through June 2001

    USGS Publications Warehouse

    Christensen, V.G.

    2001-01-01

    Because of the considerable wildlife benefits offered by the Quivira National Wildlife Refuge in south-central Kansas, there is a desire to ensure suitable water quality. To assess the quality of water flowing from Rattlesnake Creek into the refuge, the U.S. Geological Survey collected periodic water samples from December 1998 through June 2001 and analyzed the samples for physical properties, dissolved solids, total suspended solids, suspended sediment, major ions, nutrients, metals, pesticides, and indicator bacteria. Concentrations of 10 of the 125 chemicals analyzed did not meet water-quality criteria to protect aquatic life and drinking water in a least one sample. These were pH, turbidity, dissolved oxygen, dissolved solids, sodium, chloride, phosphorus, total coliform bacteria, E. coli bacteria, and fecal coliform bacteria. No metal or pesticide concentrations exceeded water-quality criteria. Twenty-two of the 43 metals analyzed were not detected, and 36 of the 46 pesticides analyzed were not detected. Because dissolved solids, sodium, chloride, fecal coliform bacteria, and other chemicals that are a concern for the health and habitat of fish and wildlife at the refuge cannot be measured continuously, regression equations were developed from a comparison of the analytical results of periodic samples and in-stream monitor measurements of specific conductance, pH, water temperature, turbidity, and dissolved oxygen. A continuous record of estimated chemical concentrations was developed from continuously recorded in-stream measurements. Annual variation in water quality was evaluated by comparing 1999 and 2000 sample data- the 2 years for which complete data sets were available. Median concentrations of alkalinity, fluoride, nitrate, and fecal coliform bacteria were smaller or did not change from 1999 to 2000. Dissolved solids, total suspended solids, sodium, chloride, sulfate, total organic nitrogen, and total phosphorus had increases in median concentrations