DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, K. V. Aneesh, E-mail: aneesh1098@gmail.com; Ravikumar, H. B., E-mail: hbr@physics.uni-mysore.ac.in; Ranganathaiah, C., E-mail: cr@physics.uni-mysore.ac.in
2016-05-06
In order to explore the structural modification induced electrical conductivity, samples of Bakelite Resistive Plate Chamber (RPC) detector materials were exposed to 100 keV Oxygen ion in the fluences of 10{sup 12}, 10{sup 13}, 10{sup 14} and 10{sup 15} ions/cm{sup 2}. Ion implantation induced microstructural changes have been studied using Positron Annihilation Lifetime Spectroscopy (PALS) and X-Ray Diffraction (XRD) techniques. Positron lifetime parameters viz., o-Ps lifetime and its intensity shows the deposition of high energy interior track and chain scission leads to the formation of radicals, secondary ions and electrons at lower ion implantation fluences (10{sup 12} to10{sup 14} ions/cm{supmore » 2}) followed by cross-linking at 10{sup 15} ions/cm{sup 2} fluence due to the radical reactions. The reduction in electrical conductivity of Bakelite detector material is correlated to the conducting pathways and cross-links in the polymer matrix. The appropriate implantation energy and fluence of Oxygen ion on polymer based Bakelite RPC detector material may reduce the leakage current, improves the efficiency, time resolution and thereby rectify the aging crisis of the RPC detectors.« less
Egilman, David
2018-01-01
Although corporate sponsorship of research does not necessarily lead to biased results, in some industries, it has resulted in the publication of inaccurate and misleading data. Some companies have hired scientific consulting firms to retrospectively calculate exposures to hazardous products during use that are no longer manufactured or sold. As an example, this paper reviews one such study-a litigation-generated study of Union Carbide Corporation's asbestos-containing product, Bakelite®. This analysis is based on previously secret documents, produced as a result of litigation. The study generated asbestos fiber exposure measurements which resulted in underestimates of actual exposures to create doubt about the hazards associated with manufacture and manipulation of Bakelite®.
Long term performance studies of large oil-free bakelite resistive plate chamber
NASA Astrophysics Data System (ADS)
Ganai, R.; Roy, A.; Shiroya, M. K.; Agarwal, K.; Ahammed, Z.; Choudhury, S.; Chattopadhyay, S.
2016-09-01
Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) experiment in the India based Neutrino Observatory (INO), India and the near detector in Deep Underground Neutrino Experiment (DUNE) at Fermilab are two such examples. A single gap bakelite RPC of dimension 240 cm × 120 cm, with gas gap of 0.2 cm, has been built and tested at Variable Energy Cyclotron Centre, Kolkata, using indigenous materials procured from the local market. No additional lubricant, like oil has been used on the electrode surfaces for smoothening. The chamber is in operation for > 365 days. We have tested the chamber for its long term operation. The leakage current, bulk resistivity, efficiency, noise rate and time resolution of the chamber have been found to be quite stable during the testing peroid. It has shown an efficiency > 95% with an average time resolution of ~ 0.83 ns at the point of measurement at ~ 8700 V throughout the testing period. Details of the long term performance of the chamber have been discussed.
Virtual Parts Engineering Research Center
2010-05-20
engineering 10 materials. High strength alloys , composites (polymer composites and metallic composites), and the like cannot merely be replaced by...ceramics, smart materials, shape memory alloys , super plastic materials and nano- structured materials may be more appropriate substitutes in a reverse...molding process using thermosetting Bakelite. For remanufacturing the part in small quantities, machining has been identified as the most economical
Dielectric Constant and Loss Data Part 2
1975-12-01
fluoride, single crystal, Melamine - formaldehyde resins , Columbia Univ., P.R.-75 IV-21,22,112; V-8,88 Manganese-magnesium ferrite, Melamine GMG, IV-2i...butylperoxy) Urea - formaldehyde resins , IV-23 hexane, P.R.-197 U.S. Army Engineering Research and War Dept., Picatinny Arsenal, see Dev. Lab., Fort...IV.-36 irradiated, P.R,-161 "Bakelite" polyvinyl chloride- "Amplifilm," IV-14; V-74 acetate, see "Vinylites" Axiiliine- formaldehyde resins , IV-21
Mowat, Fionna; Bono, Michael; Lee, R J; Tamburello, Susan; Paustenbach, Dennis
2005-10-01
In this study, a historical phenolic (Bakelite) molding material, BMMA-5353, was tested to determine the airborne concentrations of asbestos fibers released during four different activities (sawing, sanding, drilling, and cleanup of dust generated from these activities). Each activity was performed for 30 min, often in triplicate. The primary objective for testing BMMA-5353 was to quantitatively determine the airborne concentration of asbestos fibers, if any, in the breathing zone of workers. Uses of this product typically did not include sawing or sanding, but it may have been drilled occasionally. For this reason, only small quantities were sawed, sanded, and drilled in this simulation study. Personal (n = 40), area (n = 80), and background/clearance (n = 88) air samples were collected during each activity and analyzed for total fiber concentrations using phase contrast microscopy (PCM) and, for asbestos fiber counts, transmission electron microscopy (TEM). The raw PCM-total fiber concentrations were adjusted based on TEM analyses that reported the fraction of asbestos fibers, to derive a PCM-asbestos concentration that would enable calculation of an 8-hour time-weighted average (TWA). The estimated 8-hour TWAs ranged from 0.006 to 0.08 fibers per cubic centimeter using a variety of worker exposure scenarios. Therefore, assuming an exposure scenario in which a worker uses power tools to cut and sand products molded from BMMA-5353 and similar products in the manner evaluated in this study, airborne asbestos concentrations should not exceed current or historical occupational exposure limits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nabeel, A.; Khan, T.A.; Sharma, D.K.
The kinetics of co-combustion/co-cracking of Topa coal with polystyrene, poly(vinyl chloride), and bakelite have been studied by theromogravimetric analysis at a linear heating rate of 20C/min in a stream of air for combustion and in nitrogen for cracking with a flow rate of 20 cm{sup 3}/min up to the temperature of 900C under non-isothermal conditions. The order of reaction and overall activation energy of the reactions have been calculated. These studies may help in synergistic production of value-added organic compounds and spatiality chemicals from coal and plastics.
The Steerable Microcatheter: A New Device for Selective Catheterisation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soyama, Takeshi; Yoshida, Daisuke; Sakuhara, Yusuke, E-mail: yusaku@med.hokudai.ac.jp
The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.
2008-04-01
scann bakelite, and s opolish. Samp (C2H4O2), 33% hydrofluoric a o analyze micr onditions. Al age of 20 kV. PGM alloys. and post-creep n the two...spacing Table 1 alloys i only Ir temper amount Alloys from 1 wt%, th window solidus elemen the fig experim arrows indicate from al decreas compos...decreas the poin [2 [1 [3 D1 Figure I alloy wt%) compo the gra oils were prepa to the applie ss using grit olishing at a t used for al ), 10
NASA Astrophysics Data System (ADS)
Deepak, A.; Kannan, P. Muthu; Shankar, P.
This work explores the design and fabrication of graphene reinforced polyvinylidene fluoride (PVDF) patch-based microstrip antenna. Primarily, antenna was designed at 6GHz frequency and simulation results were obtained using Ansoft HFSS tool. Later fabrication of antenna was carried out with graphene-PVDF films as conducting patch deposited on bakelite substrate and copper as ground plane. Graphene-PVDF films were prepared using solvent casting process. The radiation efficiency of fabricated microstrip patch antenna was 48% entailing it to be adapted as a practically functional antenna. Both simulated and the practical results were compared and analyzed.
Resistive Plate Chambers with Gd-coated electrodes as thermal neutron detectors
NASA Astrophysics Data System (ADS)
Abbrescia, M.; Iaselli, G.; Mongelli, T.; Paticchio, V.; Ranieri, A.; Trentadue, R.
2003-12-01
Resistive Plate Chambers (RPCs) are wide spread, cheap, easy-to-build and large size detectors, used mainly to reveal ionizing particles in high energy experiments. Here a tecnique, consisting in coating the inner surface of the bakelite electrodes with a mixture of linseed oil and Gd2O3 will be reported; this allows to make RPCs sensitive also to thermal neutrons, making them suitable to be employed for industrial, medical or de-ming applications. This new type, position sensitive gas detector can be operated at atmospheric pressure, is lightweighted, has low γ-ray sensitivity, and is easy to handle even when large areas are to be covered.
Performances of RPCs in the BaBar experiment
NASA Astrophysics Data System (ADS)
Anulli, F.; Baldini, R.; Band, H.; Bionta, R.; Brau, J.; Brigljevic, V.; Buzzo, A.; Calcaterra, A.; Carpinelli, M.; Cartaro, T.; Cavallo, N.; Crosetti, G.; De Nardo, G.; De Sangro, R.; Eichenbaum, A.; Falciai, D.; Fabozzi, F.; Ferroni, F.; Finocchiaro, G.; Forti, F.; Frey, R.; Johnson, J.; Gatto, C.; Grauges-Pous, E.; Iwasaki, M.; Lange, D.; Lista, L.; Lo Vetere, M.; Lu, C.; Neal, H.; Neri, N.; Macri, M.; Messener, B.; Monge, M. R.; Moore, T.; Morganti, S.; Palano, A.; Paoloni, E.; Paolucci, P.; Passaggio, S.; Pastore, F.; Patrignani, C.; Patteri, P.; Peruzzi, I.; Piccolo, D.; Piccolo, M.; Piredda, G.; Pompili, A.; Robutti, E.; Roodman, A.; Santroni, A.; Sciacca, C.; Sinev, N.; Soha, A.; Storm, D.; Tosi, S.; Va'vra, J.; Xie, Y.; Wright, D.; Wisniewski, W.
2003-12-01
The BaBar experiment uses a big system based on RPC detectors to discriminate muons from pions and to identify neutral hadrons. About 2000 m2 of RPC chambers have been working at SLAC since the end of 1998. We report on the performances of the RPC chambers focusing on new problems discovered in the RPC behaviour. These problems started very soon after the installation of the chambers on the detector when the high-ambient temperature triggered an increase of dark currents inside the chambers and a reduction of the efficiency. Careful analysis of the BaBar data and dedicated R&D efforts in the laboratory have helped to identify the main source of the trouble in the linseed oil varnish on the bakelite electrodes.
Microstructural Evaluation of Forging Parameters for Superalloy Disks
NASA Technical Reports Server (NTRS)
Falsey, John R.
2004-01-01
Forgings of nickel base superalloy were formed under several different strain rates and forging temperatures. Samples were taken from each forging condition to find the ASTM grain size, and the as large as grain (ALA). The specimens were mounted in bakelite, polished, etched and then optical microscopy was used to determine grain size. The specimens ASTM grain sizes from each forging condition were plotted against strain rate, forging temperature, and presoak time. Grain sizes increased with increasing forging temperature. Grain sizes also increased with decreasing strain rates and increasing forging presoak time. The ALA had been determined from each forging condition using the ASTM standard method. Each ALA was compared with the ASTM grain size of each forging condition to determine if the grain sizes were uniform or not. The forging condition of a strain rate of .03/sec and supersolvus heat treatment produced non uniform grains indicated by critical grain growth. Other anomalies are noted as well.
Resistive Plate Chambers as thermal neutron detectors
NASA Astrophysics Data System (ADS)
Abbrescia, M.; Mongelli, T.; Paticchio, V.; Ranieri, A.; Trentadue, R.
2003-09-01
We present a construction procedure suitable to make Resistive Plate Chambers detectors sensitive also to thermal neutrons. This procedure, consisting in coating the inner surface of one of the RPC Bakelite electrodes with a mixture of linseed oil and Gd203, is very simple, cheap, and suitable to be employed for industrial, medical or de-mining applications. Here the results of extensive tests aimed to asset the performance of two prototypes of Gd-RPCs are shown. While the detection efficiency to thermal neutrons for a standard not Gd-coated RPC results to be about 0.1%, Gd-RPCs reach, in stand-alone, absolute efficiencies of about 10%, and, when two of these detectors are coupled together, more than 15%. In addition RPCs have excellent time resolution and good imaging performance. This new type, position sensitive gas detector can be operated at atmospheric pressure, is light-weighted, has low γ-ray sensitivity, and is easy to build and handle even when large areas are to be covered.
Biomorphous SiC ceramics prepared from cork oak as precursor
NASA Astrophysics Data System (ADS)
Yukhymchuk, V. O.; Kiselov, V. S.; Valakh, M. Ya.; Tryus, M. P.; Skoryk, M. A.; Rozhin, A. G.; Kulinich, S. A.; Belyaev, A. E.
2016-04-01
Porous ceramic materials of SiC were synthesized from carbon matrices obtained via pyrolysis of natural cork as precursor. We propose a method for the fabrication of complex-shaped porous ceramic hardware consisting of separate parts prepared from natural cork. It is demonstrated that the thickness of the carbon-matrix walls can be increased through their impregnation with Bakelite phenolic glue solution followed by pyrolysis. This decreases the material's porosity and can be used as a way to modify its mechanical and thermal characteristics. Both the carbon matrices (resulted from the pyrolysis step) and the resultant SiC ceramics are shown to be pseudomorphous to the structure of initial cork. Depending on the synthesis temperature, 3C-SiC, 6H-SiC, or a mixture of these polytypes, could be obtained. By varying the mass ratio of initial carbon and silicon components, stoichiometric SiC or SiC:C:Si, SiC:C, and SiC:Si ceramics could be produced. The structure, as well as chemical and phase composition of the prepared materials were studied by means of Raman spectroscopy and scanning electron microscopy.
NASA Technical Reports Server (NTRS)
Deshpande, Manohar D.; Dudley, Kenneth
2003-01-01
A simple method is presented to estimate the complex dielectric constants of individual layers of a multilayer composite material. Using the MatLab Optimization Tools simple MatLab scripts are written to search for electric properties of individual layers so as to match the measured and calculated S-parameters. A single layer composite material formed by using materials such as Bakelite, Nomex Felt, Fiber Glass, Woven Composite B and G, Nano Material #0, Cork, Garlock, of different thicknesses are tested using the present approach. Assuming the thicknesses of samples unknown, the present approach is shown to work well in estimating the dielectric constants and the thicknesses. A number of two layer composite materials formed by various combinations of above individual materials are tested using the present approach. However, the present approach could not provide estimate values close to their true values when the thicknesses of individual layers were assumed to be unknown. This is attributed to the difficulty in modelling the presence of airgaps between the layers while doing the measurement of S-parameters. A few examples of three layer composites are also presented.
Experimental measurement of structural power flow on an aircraft fuselage
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1989-01-01
An experimental technique is used to measure the structural power flow through an aircraft fuselage with the excitation near the wing attachment location. Because of the large number of measurements required to analyze the whole of an aircraft fuselage, it is necessary that a balance be achieved between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, the structural intensity vectors at locations distributed throughout the fuselage are measured. To minimize the errors associated with using a four transducers technique the measurement positions are selected away from bulkheads and stiffeners. Because four separate transducers are used, with each transducer having its own drive and conditioning amplifiers, phase errors are introduced in the measurements that can be much greater than the phase differences associated with the measurements. To minimize these phase errors two sets of measurements are taken for each position with the orientation of the transducers rotated by 180 deg and an average taken between the two sets of measurements. Results are presented and discussed.
Operation of low-noise single-gap RPC modules exposed to ionisation rates up to 1 kHz /cm2
NASA Astrophysics Data System (ADS)
Ćwiok, M.; Dominik, W.; Górski, M.; Królikowski, J.
2004-11-01
Two single gap medium-size RPC modules, made of bakelite plates of very good mechanical quality of the surface and having initial volume resistivity of 1 ×1010 Ω cm, were tested in the Gamma Irradiation Facility at CERN at ionisation rates up to 1 kHz /cm2. The internal surfaces facing the gas volume of one RPC module were cladded with a thin layer of linseed oil varnish for comparison of oiled and non-oiled RPC operation. The results refer to the gas mixture of C2H2F4/isobutane (97:3) with SF6 addition below 1%. The single gap modules exhibited full detection efficiency plateau for the high voltage range of about 1 kV at full intensity of gamma rays. Good timing characteristics allowed to reach 95% efficiency at fully opened irradiation source with time window of 20 ns. The intrinsic noise rate for a non-oiled and an oiled RPC gap was, respectively, below 5 and 1 Hz /cm2 at full efficiency over 1 kV voltage range.
Compton profiles of some composite materials normalized by a new method
NASA Astrophysics Data System (ADS)
Sankarshan, B. M.; Umesh, T. K.
2018-03-01
Recently, we have shown that as a novel approach, in the case of samples which can be treated as pure incoherent scatterers, the effective atomic number Zeff itself could be conveniently used to normalize their un-normalized Compton profiles. In the present investigation, we have attempted to examine the efficacy of this approach. For this purpose, we have first determined the single differential Compton scattering cross sections (SDCS) of the elements C and Al as well as of some H, C, N and O based polymer samples such as bakelite, epoxy, nylon and teflon which are pure incoherent scatterers. The measurements were made at 120° in a goniometer assembly that employs a high resolution high purity germanium detector. The SDCS values were used to obtain the Zeff and the un-normalized Compton profiles. These Compton profiles were separately normalized with their Zeff values (for Compton scattering) as well as with the normalization constant obtained by integrating their Hartree-Fock Biggs et al Compton profiles based on the mixture rule. These two sets of values agreed well within the range of experimental errors, implying that Zeff can be conveniently used to normalize the experimental Compton profiles of pure incoherent scatterers.
Experimental measurement of structural power flow on an aircraft fuselage
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1991-01-01
An experimental technique is used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage is a relatively large structure, requiring a large number of measurement locations to analyze the whole of the structure. For the measurement of structural intensity, multiple point measurements are necessary at every location of interest. A tradeoff is therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, structural intensity vectors are measured at locations distributed throughout the fuselage. To minimize the errors associated with using the four transducer technique, the measurement locations are selected to be away from bulkheads and stiffeners. Furthermore, to eliminate phase errors between the four transducer measurements, two sets of data are collected for each position, with the orientation of the platform with the four transducers rotated by 180 degrees and an average taken between the two sets of data. The results of these measurements together with a discussion of the suitability of the approach for measuring structural intensity on a real structure are presented.
NASA Astrophysics Data System (ADS)
Rao, D. V.; Cesareo, R.; Brunetti, A.; Gigante, G. E.; Akatsuka, T.; Takeda, T.; Itai, Y.
2004-09-01
Relativistic and nonrelativistic Compton profile cross sections for H, C, N, O, P, and Ca and for a few important biological materials such as water, polyethylene, lucite, polystyrene, nylon, polycarbonate, bakelite, fat, bone and calcium hydroxyapatite are estimated for a number of Kα x-ray energies and for 59.54 keV (Am-241) γ photons. Energy broadening and geometrical broadening (ΔG) is estimated by assuming θmin and θmax are symmetrically situated around θ=90°. FWHM of J(PZ) and FWHM of Compton energy broadening are evaluated at various incident photon energies. These values are estimated around the centroid of the Compton profile with an energy interval of 0.1 and 1.0 keV for 59.54 keV photons. Total Compton, individual shell, and Compton energy-absorption scattering cross sections are evaluated in the energy region from 0.005 to 0.5 MeV. It is an attempt to know the effect of Doppler broadening for single atoms, many of which constitute the biological materials.
Water Ingress Testing of the Turbula Jar and U-233 Lead Pig Containers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reeves, Kirk Patrick; Karns, Tristan; Smith, Paul Herrick
Understanding the water ingress behavior of containers used at the TA-55 Plutonium Facility has significant implications for criticality safety. The purpose of this report is to document the water ingress behavior of the Turbula Jar with Bakelite lid and Viton gaskets (Turbula Jar) used in oxide blending operations and the U-233 lead pig container used to store and transport U-233 material. The technical basis for water resistant containers at TA-55 is described in LA-UR-15-22781, “Water Resistant Container Technical Basis Document for the TA-55 Criticality Safety Program.” Testing of the water ingress behavior of various containers is described in LA-CP-13-00695, “Watermore » Penetration Tests on the Filters of Hagan and SAVY Containers,” LA-UR-15-23121, “Water Ingress into Crimped Convenience Containers under Flooding Conditions,” and in LA-UR- 16-2411, “Water Ingress Testing for TA-55 Containers.” Water ingress criteria are defined in TA55-AP-522 “TA-55 Criticality Safety Program”, and in PA-RD-01009 “TA55 Criticality Safety Requirements.” The water ingress criteria for submersion is no more than 50 ml of water ingress at a 6” water column height for a period of 2 hours.« less
More environment-friendly and safer working gas mixtures for Bakelite RPCs operated in streamer mode
NASA Astrophysics Data System (ADS)
Zhang, Qingmin; Lv, Zhipeng; Lv, Jinge; Zhang, Jiawen; Xu, Jilei; Ning, Zhe
2017-08-01
This paper presents experimental results of RPCs performances with different working gas mixtures. Owing to Freon's high global warming potential, its threat to RPCs aging and its large consumption in large particle physics experiments, studies to minimize the concentration of HFC-134A, and even its complete replacement, have been undertaken. In addition, the reduction of iso-butane is also a favorable strategy, due to the flammability level of the gas mixture. Freon-less working gas mixture of Ar/HFC-134A/i-C4H10/CO2=20/0/8/72 was chosen with plateau efficiency of 86.3% and noise rate of 0.61 Hz/cm2. For working gas with lower ratio of Freon, Ar/HFC-134A/i-C4H10/CO2=20/20/8/52 was suggested with plateau efficiency of 91.0% and noise rate of 0.19 Hz/cm2, in which Freon was decreased by 22% compared to the BESIII RPC gas mixture. Furthermore, iso-butane was decreased to 6% with RPC's efficiency of 90% and noise rate of 0.20 Hz/cm2 achieved. Finally, the explanation of RPC's different performances at various working gas mixtures has been validated by the investigation of secondary streamers. This study will be helpful for RPC's application in future large particle physics experiments, in which RPCs can run in streamer mode.
Rajan, K N Govinda; Selvam, T Palani; Bhatt, B C; Vijayam, M; Patki, V S; Vinatha; Pendse, A M; Kannan, V
2002-04-07
The primary standard of low air kerma rate sources or beams, maintained at the Radiological Standards Laboratory (RSL) of the Bhabha Atomic Research Centre (BARC), is a 60 cm3 spherical graphite ionization chamber. A 192Ir HDR source was standardized at the hospital site in units of air kerma strength (AKS) using this primary standard. A 400 cm3 bakelite chamber, functioning as a reference standard at the RSL for a long period, at low air kerma rates (compared to external beam dose rates), was calibrated against the primary standard. It was seen that the primary standard and the reference standard, both being of low Z, showed roughly the same scatter response and yielded the same calibration factor for the 400 cm3 reference chamber, with or without room scatter. However, any likelihood of change in the reference chamber calibration factor would necessitate the re-transport of the primary standard to the hospital site for re-calibration. Frequent transport of the primary standard can affect the long-term stability of the primary standard, due to its movement or other extraneous causes. The calibration of the reference standard against the primary standard at the RSL, for an industrial type 192Ir source maintained at the laboratory, showed excellent agreement with the hospital calibration, making it possible to check the reference chamber calibration at RSL itself. Further calibration procedures have been developed to offer traceable calibration of the hospital well ionization chambers.
Fabrication and characterization of a 3D Positive ion detector and its applications
NASA Astrophysics Data System (ADS)
Venkatraman, Pitchaikannu; Sureka, Chandrasekaran Senbagavadivoo
2017-11-01
There is a growing interest to experimentally evaluate the track structure induced by ionizing particles in order to characterize the radiobiological quality of ionizing radiation for applications in radiotherapy and radiation protection. To do so, a novel positive ion detector based on the multilayer printed circuit board (PCB) technology has been proposed previously, which works under the principle of ion induced impact ionization. Based on this, an upgraded 3D positive ion detector was fabricated in order to improve its efficiency and use it for various applications. To improve the efficiency of the detector, cathodes with different insulators (Bakelite plate and Steatite Ceramics) and conducting layers (ITO, FTO, and Gold coated cathode) were studied under various gaseous media (methane, nitrogen, and air) using Am-241, Co-60, Co-57, Na-22, Cs-137, and Ba-133 sources. From this study, it is confirmed that the novel 3D positive ion detector that has been upgraded using gold as strip material, tungsten (87%) coated copper (13%) as the core wire, gold coated ceramic as cathode, and thickness of 3.483 mm showed 9.2% efficiency under methane medium at 0.9 Torr pressure using an Am-241 source. It is also confirmed that when the conductivity of the cathode and thickness of the detector is increased, the performance of the detector is improved significantly. Further, the scope of the detector to use in the field of radiation protection, radiation dosimetry, gamma spectrometry, radiation biology, and oncology are reported here.
A simple cryogenic holder for tensile testing of soft biological tissues.
Lepetit, J; Favier, R; Grajales, A; Skjervold, P O
2004-04-01
To overcome the difficulty of gripping soft biological materials for tensile test, a simple inexpensive cryogenic holder was developed which allows rapid (3 min) preparation of samples. It is made of 6 parts, built in a bakelite cloth, which is an excellent thermal isolant, and is used with rectangular (8x10(-2)x10(-2)x10(-2)m) samples. The holder with the sample inside is completely immersed in liquid nitrogen for 50 s. This duration allows the freezing of the sample ends on a 10(-2)m length and gives a very flat freezing surface throughout the sample cross section. The 6x10(-2)m central part of the sample remained at ambient temperature. Two parts of the holder help maintain the sample until its ends are vertically gripped in the tensile machine thus avoiding any sample deformation during this step. No pressure was applied on the frozen part of the sample by grips of the tensile machine and this avoids breaks in this region. The sample is fixed by adhesion forces (>1 kN) between its frozen parts and 2 pieces of the holder. The procedure has been successfully tested with bovine and salmon muscle samples and results show tensile breaks randomly distributed in the unfrozen region of the samples. Particular attention has been paid to obtain a very flat freezing surface so that the axial strain is equal throughout the sample and therefore any strain-related mechanical parameters can be accurately determined. The dimensions of the holder can be easily modified to fit other sample geometries and can be used with other biological materials.
Mechanisms Affecting Performance of the BaBar Resistive Plate Chambers and Searches for Remediation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Changguo
2003-09-19
The BaBar experiment at PEPII relies on the Instrumentation of the Flux Return (IFR) for both muon identification and KL detection. The active detector is composed of Resistive Plate Chambers (RPC's) operated in streamer mode. Since the start of operation the RPC's have suffered persistent efficiency deterioration and dark current increase problems. The ''autopsy'' of bad BaBar RPC's revealed that in many cases uncured Linseed oil droplets had formed on the inner surface of the Bakelite plates, leading to current paths from oil ''stalagmites'' bridging the 2 mm gap. In this paper a possible model of this ''stalagmite'' formation andmore » its effect on the dark current and efficiency of RPC chambers is presented. Laboratory test results strongly support this model. Based upon this model we are searching for solutions to eliminate the unfavorable effect of the oil stalagmites. The lab tests show that the stalagmite resistivity increases dramatically if exposed to the air, an observation that points to a possible way to remedy the damage and increase the efficiency. We have seen that flowing an oxygen gas mixture into the chamber helps to polymerize the uncured linseed oil. Consequently the resistivity of the bridged oil stalagmites increases, as does that of the oil coating on the frame edges and spacers, significantly reducing the RPC dark currents and low-efficiency regions. We have tested this idea on two chambers removed from BaBar because of their low efficiency and high dark current. These test results are reported in the paper, and two other remediation methods also mentioned. We continue to study this problem, and try to find new treatments with permanent improvement.« less
Investigation of production of continuous off axis fibre reinforced thermoplastic material
NASA Astrophysics Data System (ADS)
McDonald, Philip C.
Fibre reinforced composites have been used in the engineering industry for many years since the discovery of glass fibre in 1930 and its first use to reinforce phenolic resin to form Bakelite. Since then thermoplastic and thermosetting composites have spread into almost every industry from marine to aerospace, automotive to motorsport, luggage to the hobby industry and even fashion. This vast range of applications for composite materials is due to their high strength to weight ratio, excellent impact absorption properties, lack of corrosion, and reformability. In recent years a government directive has forced automotive manufacturers to look at lighter and more efficient vehicles to reduce carbon emissions. This can be achieved by using fibre reinforced thermoplastics to replace steel panels throughout the vehicle.Steel panels from a Nissan Qashqai were tested to determine the failure loads of each panel which the replacement thermoplastic material had to match or better. After extensive testing in a laboratory a tailored laminate lay-up with 5 laminate layers has been developed to replace structural steel components in vehicles. This tailored laminate stack up has a higher failure load than the steel components tested from the Nissan Qashqai while reducing the mass by at least 50%. The key drivers within the automotive industry are fuel savings and reduced vehicle mass, the use of this material and the potential it has in the mass production automotive industry can have a high impact on the overall mass of the vehicle which would invariably have a positive effect to the fuel consumption, thereby improving fuel economy in petrol and diesel vehicles, and increasing the range of electric vehicles.Throughout this project a prototype machine was developed and built to achieve mass production of this 5 ply laminate at a rate of more than 345,000 laminates per year with a processing cost of 3 1p making it available to the mass production market. The estimated production cost represents approximately 2.4% of the finished product price.
NASA Technical Reports Server (NTRS)
Kniskern, Marc W.
1990-01-01
The thermal effects of simulant gas injection and aerodynamic heating at the model's surface on the measurements of a non-watercooled, flow through balance were investigated. A stainless steel model of a hypersonic air breathing propulsion cruise missile concept (HAPCM-50) was used to evaluate this balance. The tests were conducted in the 20-inch Mach 6 wind tunnel at NASA-Langley. The balance thermal effects were evaluated at freestream Reynolds numbers ranging from .5 to 7 x 10(exp 6) ft and angles of attack between -3.5 to 5 deg at Mach 6. The injection gases considered included cold air, hot air, and a mixture of 50 percent Argon and 50 percent Freon-12. The stagnation temperatures of the cold air, hot air, and Ar-Fr(12) reached 111, 214, and 283 F, respectively within the balance. A bakelite sleeve was inserted into the inner tube of the balance to minimize the thermal effects of these injection gases. Throughout the tests, the normal force, side force, yaw moment, roll moment, and pitching moment balance measurements were unaffected by the balance thermal effects of the injection gases and the wind tunnel flow. However, the axial force (AF) measurement was significantly affected by balance heating. The average zero shifts in the AF measurements were 1.9, 3.8, and 5.9 percent for cold air, hot air, and Ar-Fr(12) injection, respectively. The AF measurements decreased throughout these tests which lasted from 70 to 110 seconds. During the cold air injection tests, the AF measurements were accurate up to at least ten seconds after the model was injected into the wind tunnel test section. For the hot air and Ar-Fr(12) tests, the AF measurements were accurate up to at least five seconds after model injection.
Thermal Stability of Jet Fuels: Kinetics of Forming Deposit Precursors
NASA Technical Reports Server (NTRS)
Naegeli, David W.
1997-01-01
The focus of this study was on the autoxidation kinetics of deposit precursor formation in jet fuels. The objectives were: (1) to demonstrate that laser-induced fluorescence is a viable kinetic tool for measuring rates of deposit precursor formation in jet fuels; (2) to determine global rate expressions for the formation of thermal deposit precursors in jet fuels; and (3) to better understand the chemical mechanism of thermal stability. The fuels were isothermally stressed in small glass ampules in the 120 to 180 C range. Concentrations of deposit precursor, hydroperoxide and oxygen consumption were measured over time in the thermally stressed fuels. Deposit precursors were measured using laser-induced fluorescence (LIF), hydroperoxides using a spectrophotometric technique, and oxygen consumption by the pressure loss in the ampule. The expressions, I.P. = 1.278 x 10(exp -11)exp(28,517.9/RT) and R(sub dp) = 2.382 x 10(exp 17)exp(-34,369.2/RT) for the induction period, I.P. and rate of deposit precursor formation R(sub dp), were determined for Jet A fuel. The results of the study support a new theory of deposit formation in jet fuels, which suggest that acid catalyzed ionic reactions compete with free radical reactions to form deposit precursors. The results indicate that deposit precursors form only when aromatics are present in the fuel. Traces of sulfur reduce the rate of autoxidation but increase the yield of deposit precursor. Free radical chemistry is responsible for hydroperoxide formation and the oxidation of sulfur compounds to sulfonic acids. Phenols are then formed by the acid catalyzed decomposition of benzylic hydroperoxides, and deposit precursors are produced by the reaction of phenols with aldehydes, which forms a polymer similar to Bakelite. Deposit precursors appear to have a phenolic resin-like structure because the LIF spectra of the deposit precursors were similar to that of phenolic resin dissolved in TAM.
Experimental study on the effects of fixed boundaries in channelized free surface dry granular flows
NASA Astrophysics Data System (ADS)
Sarno, Luca; Carleo, Luigi; Nicolina Papa, Maria
2017-04-01
The dynamics of granular mixtures, involved in geophysical flows like avalanches and debris flows, is far from being completely understood. Several features of their motion, such as rheological stratification, non-local and boundary effects, still represent open problems. Experimental investigations at laboratory scale are an important tool that can provide insights about the dynamics of gravity driven granular flows. The measuring techniques should be non-invasive in order to measure undisturbed flows. In this work we present an experimental campaign devoted to the measurement of the velocity profiles of free surface steady granular flows in an open channel. To achieve this goal the flows were recorded by two cameras and velocity profiles were obtained by image analysis. The employed granular medium consists of acetal-polymeric beads with a mean diameter of 3mm and an estimated internal friction angle of 27°. All the experiments have been performed in a 2m-long plexiglas flume with a rectangular cross-section and a slope angle of 30°. The upper part of the channel was used as a reservoir where the material was loaded before each run and then let flow down through an adjustable gate. Several mass flow rates were investigated. Three different basal surfaces were employed so as to observe slip and non-slip boundary conditions: a smooth Bakelite surface, a roughened surface, obtained by gluing a layer of grains on the bed surface and a sandpaper surface with characteristic length of the roughness equal to 425 µm. The flume is equipped with two high-speed cameras, one placed aside the channel and the other one perpendicular to the channel bed, as to get both side-wall and free surface velocity profiles. The particle image velocimetry open-source code, PIVlab, is employed for estimating the flow velocities. All the free surface velocity profiles show an approximately parabolic shape with a maximum at the cross-section midpoint and a minimum at the side-walls, due to the wall friction. Different kinds of side-wall velocity profiles are observed. As regards the smooth basal surface, a slip velocity at the bed is observed. The profiles are Bagnold-type near the free surface and become linear as the depth increases. On the glued-grain basal surface the flow velocity at the bed is null and all the velocity profiles show a rheological stratification with a lower exponential tail and an upper linear profile. Grain rolling is observed at the sandpaper bed, instead. With the increase of flow depths, the velocity profiles gradually shift from the ones observed on the smooth bed to the ones observed on the glued-grain bed. In order to further understand the constitutive behaviour of granular mixtures, it is useful to perform simultaneous measurements of flow velocity and volume fraction. In this perspective, a new series of experiments is actually undergoing for the measurement of the volume fraction.